Loading...
HomeMy WebLinkAbout1525 FARADAY AVE; ; AS0500079/12/23, 2:31 PM AS050007 Permit Data City of Carlsbad Sprinkler Permit Job Address: 1525 FARADAY AV Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: Permit No: AS050007 Status: ISSUED Applied 1/26/2005 Approved: 1/31/2005 Issued: 1/31/2005 PC #: Inspector: Project Title: CROWN PACIFIC, SUITE 180 T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: COSCO FIRE PROTECTION STEIO5 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 115 0 115 0 about:blank I/I Bulletin 136 Rev.L neli ble Model Fl FR Model F1FR Recessed Quick Response Sprinklers CD CD -S 0) 0) CD I- Model Fl FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters' Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council (LPC, UK) NYC BS&A No. 587-75-SA Meets MIL-S-901C and MIL-STD 167-1 Verband der Schadenversicherer (VdS, Germany) NYC MEA 258-93-E I UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Product Description Reliable Models F1FR and F1FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models Fl FR and Fl FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The temperature rating of the sprinkler is identified by the color of the glass bulb. Upright Pendent Vertical Sidewall Conventional Horizontal Sidewall HSW 1 Deflector Recessed Pendent Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 NZ Mode! Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position K Factor Sprinkler Height Approval Organization Sprinkler Identification Number(SIN) US Metric SSU SSP )' (15mm) Standard Orifice with )" NPT (R)) Thread 5.6 80 2.2' (56mm) 1,2,3,456,7 R3625 R3615 %" (20mm) Large Orifice with X11 NPT (R'A)Thread 8.0 115 2.3" (58mm) 12,3,4,7,8 R3622 R3612 Y,," (17mm) Small Orifice with Y2" NPT (R)) Thread 4.2 60 2.54" (65mm) 1,2,8 R3623 R3613 %" (10mm) Small Orifice with )" NPT (R)) Thread 2.8 40 2.54- (65mm) 1,2,8 R3621 R3611 l0mm Orifice XLH with R%"Thread 4.2 60 56.1mm 4.6,7 R3624 R3614 Conventional-Install in Upright or Pendent Position 4.2 5.6 8.0 1 60 80 115 56.1mm 56.1mm 58.4mm 1 - 4,6,7 4,7 R3674 R3675 R3672 l0mm Orifice XLH with R%Thread 15mm Standard Orifice with )" NPT (R)) Thread 20mmLarge Orifice with 3A"NPT(R34)mread Upright Pendent Upright Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval0 Organizations Sprinkler Identification Number (SIN) us Metric X" (15mm) ,Y;NPT(R½) 5.6 80 2.2' (56mm) 1,2,3,4.5,7,8 R3615 %7(20mm) %"NPT(R'A) 8.0 115 2.3"(58mm) 1,2,3 R3612 " (11mm) "NPT(R1/2) 4.2 60 2.54 (65mm) 1,2,8 R3613 % (10mm) ,3" NPT (R1/2) 2.8 1 40 2.54 (65mm) 1,2,8 R3611 10mm R% 4.2 60 1 56.1mm 4,7 R3614 "Refer to escutcheon data table for approvals and dimensions. 2 l/41a.EC&( 15/f6 CM (49.2m'n) I I riz I '• x 'a RLCIR nm cOLLAR ima ir L 13.2mm) ;;7m.k _-J (72.A-1 IWW1O (I) RR 10 fU1D*D*4 DATA TARE FOR AFRROWLS APØ 2. Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size K Factor US Metric Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) Y2" NPT (RY2)__f 5.6 80 2.2 (56mm) 1,2,3,6,8 R3685 15mm ½" NPT (R'/2) 5.6 80 2.2" (56mm) 4(1) (1) LPC Approval is for Pendent position only. I Orientation I Deflector to Ceiling I Dimension (Mm. - Max.) I Upright 411- 12" (102mm - 305mm) I Pendent I 6 - 12" (152mm - 305mm) Vertical Sidewall Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: K Factor Approval Organizations and Type of Approval Sprinkler Identification US I Metric Light Hazard I Ordinary I Hazard Nominal Orifice Thread Size Sprinkler Length Number (SIN) X"(l5mm) " NPT(R½) 5.6 80 2.63(67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL and ULC Listing permits use with Fl or F2 recessed escutcheon. I-lorlzontal siaewall Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1FR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutch- eons illustrated are the only recessed escutcheons to be used with the Model Fl FR Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Sprinkler Wrench. When installing Model Fl FR Recessed Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Use the Model RC1 Wrench for installing F1FR Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. Temperature Ratings Classification Sprinkler —Tempe'ature Max. Ambient Temp. OF Bulb Color C Ordinary 57 135 10o°F(38°c) Orange Ordinary 68 iss 100°F(381c) Red Intermediate 79 175 150°F(661c) Yellow Intermediate 93 200 150°F(66°c) Green High (1) 141 286 225OF(1070c) Blue (1) Not available for recessed sprinklers. Escutcheon Data Escutcheon Faceof Fitting Model A to ceiling or EDkToWm Wail imenslon 12,4 X6 _15/Fl 19mm) (5mm - 24mm) F2 1,2,3,4,5,7,8 1" X6" -X" (13mm) (25mm) (5mm- 17mm) F1' 1,2 Fully Recessed t11 mm 12 Fully Retracted Push-on/ Thread-off (24mm) Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes ("4 Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated White Painted (3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult the factory for details. FM Approvals is limited to bronze and brass, chrome or black plated finishes only. FP Push-on/Thread-off escutcheon Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the united States, Canada and foreign countries. Manufactured by Reliabld The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices (800)848-6051 Sales Fax (914)668-3470 Corporate Offices www.rellablesprinkler.com Internet Address ®Recycled Paper Revision lines indicate updated or new data EG.Plinted m USA. 3O3 P1N9999970027