HomeMy WebLinkAbout1525 FARADAY AVE; ; AS0501899/12/23, 2:34 PM AS050189 Permit Data
City of Carlsbad
Sprinkler Permit
Job Address: 1525 FARADAY AV
Permit Type: SPRINK
Parcel No:
Lot #: 0
Reference No.:
Permit No: AS050189
Status: PENDING
Applied 9/22/2005
Approved:
Issued:
PC #: Inspector:
Project Title: GOOD SOURCE SOLUTIONS,#200 FIRE SPRINKLER PLAN
CHECK & INSPECTIONS
Applicant:
WEST COAST FIRE PROTECTION
271 ROYMAR RD
SUITE F
OCEANSIDE, CA
(760)754-8472
Owner:
Fees ($) Add'I Fees ($) Total ($) Balance ($)
120 0 120 0
about:blank 1/1
Models V3411 and V3412
Extended CoveragelLight Hazard (ECLH)
Pendent and Recessed Pendent
Standard and Quick Response
many angles, reducing
assembly effort. This sprin-
kler is available In various
temperature ratings (see
chart on page 2) and fin-
ishes to meet many design
requirements.
Sprinkler Operation
The operating mechanism
is a frangible glass bulb
which contains a heat
responsive liquid. During a
fire, the ambient tempera-
ture rises causing the liquid
in the bulb to expand.
When the ambient temper-
ature reaches the rated
temperature of the sprin-
kler, the bulb shatters. As a
result, the waterway Is
cleared of all sealing parts
and water is discharged
towards the deflector. The
deflector is designed to dis-
tribute the water in a pat-
tern that Is most effective
in controlling the fire.
Coverage
Extended spray coverage Is
up to 400 square feet (37,2
sq. in) per NFPA 13.
p
taUIiC XX V34, KII2
PRODUCT DESCRIPTION
These Model V34 ECLH
sprinklers are designed
with a larger orifice size to
V3411 provide added coverage at
V3412 normal light hazard operat-
ing pressures. The design
Incorporates state-of-the-
art, heat responsive, frangi-
ble glass bulb design (stan-
dard or quick response) for
See Victaulic prompt, precise operation
Pendent publication 10.01
for details. The the cast frame Is more
streamlined and attractive
than traditional sand cast
4A
frames. It is cast with a
hex-shaped wrench boss to
allow easy tightening from
Recessed
Pendent
TECHNICAL SPECIFICATIONS
Models: V341 1. V3412
Style: Extended Coverage!
Light I lazard - Pendent.
Recessed Pendent
Nominal Orifice Size:
%" (16 mm)
K-Factor: 11.2 Imp. (16.2 S.1.^)
Nominal Thread Size:
VV NPT (20 turn)
Max. Working Pressure:
175 psi (1200 kPa)
Factory Hydrostatic Test:
100% @ 500 psi (34 50 kPa)
Mm. Operating Pressure:
5 P' (34 kPa)
Temperature Rating: See
chart on page 2.
MATERIAL
SPECIFICATIONS
Pendent Deflector:
Bronze per UNS C5 1000
Bulb: Glass with glycerin solu-
tion.
Bulb Nominal Diameter:
U Standard: 5,0 rum
U Quick Response: 3,0 mm
Load Screw: Bronze per UNS
C65100
Pip Cap: Bronze per UNS
C65100
Spring: Beryllium nickel
Seal: Tellon5 tape
Frame: Die cast brass 65-30
Lodgement Spring: Stainless
steel per UNS S30200
ACCESSORIES
Installation Wrench:
U Open End: V34
U Recessed: V34
Sprinkler Finishes:
U Plain brass
U Chrome plated
U White painted
U Custom painted50
For escutcheons, cabinets and
other accessories relci' to sepa-
rate sheet.
For K-Factor when pressure is mea-
sured in Bar, multiply S.I. units by 10.0.
'Teflon is a registered trademark of
Dupont Co.
"UL Usted for corrosion resistance in all
configurations.
Exaggerated for clarity
VICTAULIC@ IS AN ISO 9001 CERTIFIED COMPANY
Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific
Phone: 1-800-PICK-VIC (1-800-142.5842) Phone: 905-884.1444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035
Fax: 610-250-8811 Fax: 905-884-9114 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535
e-mail:pickvic@victaufic.com e-mail: viccanada@victaulic.com e-mail: vlceuro@victaulic.be e-mail: vical@victaulic.com e-mail: vicap@victaulic.com
i
-
2552 Rev.D 5103 0 Iglsed Trademark of Vlcuullc 0 Ccpystght 21103 VtctaUtc Flirted in U.S.A.
APPROVALSILISTINGS
Approved Temperature Ratings * @ (Refer to notes below)
Nominal Room Size - Feetlmeters
K-Factor
16 X 16 18 X 18 20 X 20 Orifice Size Imperial Deflector
Model lncheslmm SJ.° Response Type 49 X 49 5,5X 5,5 5,1 X 6,1
11.2 1,3,4,5-A 1,3,4,5-A 1,3,4,5-A
V3411 16 16.2 Standard Pendent 2-B 2-B 2-B
11.2 Recessed Pendent 1.3.4,5-A 1.3.4,5-A 1.3,4.5-A
V3411 16 16,2 Standard UptowAdjustment 2-0 2-D 2-0
V34 11 16
11.2 16.2 Standard Recessed Pendent
Up 1o~' Adjustment 1,3,4.5-A 1,3,4,5-A 1,3.4.5-A
94 11.2 1,3,4,5-A 1.3,4,5-A 1.3,4,5-A
V34 12 16 16.2 Quick Pendent 2-0 2-0 2-0
94 11.2 Recessed Pendent 1,3;4,5-A 1,3.4,5-A 1.3.4,5-C
V3412 16 16,2 Quick UptoWAdjustment 2-E 2-E 2-E
V3412 94
16
11.2
16.2 Quick Recessed Pendent
Uptot4'Adjustment 1,3.4.5-A 1,3.4.5-A 1,3.4.5-C
:1 Ustings and approval as of printing. Not all temperature rating combinations are Approved or Listed. Check Victaulic For specilic combinatIons.
"For K-Factor wtieri pressure is measured in Bar, multiply S.I. units by 10.0.
55 Light Hazard only.
NOTES
Approval Temperature Rating
1- UL A- 135F (57'C). 155'F (68'C). 175'F (79'C), 200F (93'C)
2- FM B- 135'F(57'C), 155'F (68'C). 1751 (79'C)
3- ULC C -135'F (57'C). 1751 (79'C)
4-NYC/MEA1 0- 135'F (57'C), 155'F (68'C)
5- CSFM § E- 135'F (57'C)
MEA #62-99-E § CSFM #7690.0531:112
RATINGS
All glass bulbs are rated for
temperatures from -67°F
(-55°C) to those shown in
adjacent table.
Temperature -
Sprinkler Vlctaulic Glass
Temperature Part Nominal Maximum Bulb
Classification Identification Temperature Rating Ambient Temp. Allowed Color
Ordinary A 135
57
100
38 Orange
Ordinary C 15
68
10
38 Red
Intermediate E 175
79
150
65 Yellow
Intermediate F 200
93
150
65 Green
ORDERING INFORMATION
Please specify the following
when ordering: U Sprinkler Model Number U K-Factor U Sprinkler Finish
U Style U Thread Size U Escutcheon Finish
U Temperature Rating U Quantity U Wrench Model Number
Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation
of any sprinklers.
Always wear safety glasses and foot protection.
Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 • Installation rules, especially those governing obstruction, must be Strictly followed.
Painting, plating, or any re-coating of sprinklers (other than that supplied by Viclaulic) is not allowed.
Failure to follow these instructions could result in serious personal injury andlor property damage.
The owner is responsible for maintaining the fire protection System and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the
current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional
maintenance, testing, and inspection requirements that must be followed.
If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton,
Pennsylvania 18044-0031, 610.559.3300.
40.30-2
DIMENSIONS
2W (60 mm)
Max. Hole
2(5I mm)
Mm Hole
2W I
(64080) 1W
(')
I 1W
(35 m)
Standard Pendent
V3411, V3412
1W
(29 mm) y Typical Ceiling Tile i#i>f
1%"
(34 mm) - Finished Surface
MAXIMUM RECESS
L 2VAe
(75 mm)
MAXIMUM EXTENSION
W Adjustment
Recessed - V3411, V3412 (D,azWngnoflo scale)
w (18mm) (16m
11.
(47 mm)
2W (60 mm)
Max. Hole
2(51 mm)
Mm. Hole
1W
(35 mm)
(24 mm) 16"
(16mm) Typical Ceilng inn le
d1ba
1W
1%" Finished Surface (29 mm)
(47 mm)
MAXIMUM RECESS
(75 mm)
MAXIMUM EXTENSION
W Adjustment
Recessed -V3411, V3412 (D'swngnc?b scale)
AVAILABLE WRENCHES
V34
Open End
V34
Recessed
Pendent
Recessed Pendent
ROOM SIZE SPRINKLER PERFORMANCE FLOW AND PRESSURE (MINIMUM)
V3411,V3412
RDom Flow Rate End Sprinkler Pressure
size GPMILPM PSIIkPa
FM UL FM UL feetlm
16X16 30 30 7 7 4,9X4.9 115 115 50 50
18X18 33 33 9 9
5,5X5,5 125 125 60 60
20X20 40 40 13 13 61 X6,1 150 150 90 90
40.30 -3
'1?'II,41'1'Ii 19k. diII 1,11 r..a ISl.fl fl'lfl'J 1
i•i•uum•u•uuuu ••UU•lU•llI•L•ll I•IUIlUUUUlUILII• u•uasum•i•iiui u•uuu•uuiuuuiu
2' 4' 6' 81 10' 12' 14' 16' 18'
0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m 49m 5,5m
10'
3,0 m
8'
2,4 m
6'
1,8 m
4'
1,2 m
2-
0,6 in
0
30 GPM
113,6 1PM
33 GPM
124,9LPM
40 GPM
151,4 LPM
DISTRIBUTION PATTERNS
MODELS V3411, V3412
K11.2 ECLH PENDENT AND RECESSED PENDENT
Minlumum Installation Spacing
Response Feetlmeters
V3411 -Standard 10.0
3,0
6.0 V3412-Quick
NOTES:
Data shown Is approximate and can vary Clue to differences In installation.
These graphs Illustrate approximate trajectories. floor-wetting. and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are
provided as lnformatloti for guidance In avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules ror installation. Refer to
the appropriate NFPA National Fire Code or the Authority having Jurisdiction for specific information regarding obstructions, spacing limitations and area of
coverage requirements. Failure to follow these guidelines could adversely affect, the performance of the sprinkler and will void all Listings. Approvals and War-
rant ins.
All patterns are symlnelrical In ihe centerline of the waterway.
WARRANTY Refer to the Warranty section
of the current Price List or
contact Victaulic for details.
This product shall be manufactured by Victaulic company. All products to be installed in accordance with currant Victaulic installationlassombly instructions.
Victaulic reserves tho right to change product specifications, designs and standard equipment without notice and without incurring obligations.
40.30-4
many angles, reducing
assembly effort. This sprin-
kler is available in various
temperature ratings (see
chart on page 2) and fin-
ishes to meet many design
requirements.
The recessed pendent
should be utilized with a
Model V27 recessed
escutcheon which pro-
vides up to VV (19 mm) of
adjustments.
Sprinkler Operation
The operating mechanism
is a frangible glass bulb
which contains a heal
responsive liquid. During a
fire, the ambient tempera-
lure rises causing the liquid
in the bulb 10 expand.
When the ambient temper-
ature reaches the, rated
temperalurc of the sprin-
kler, the bulb shatters. As a
result, the waterway is
cleared of all sealing parts
and water is discharged
towards the deflector. The
deflector is designed to dis-
tribute the water in a pat-
tern that is most effective
in controlling the fire.
Coverage
For coverage area and
sprinkler placement, refer
to NFPA 13 standards.
taUIiC
XX V27, K5.6
Models V2703, V27041, V2707 and V2708
Standard Spray
Upright, Pendent and Recessed Pendent
Standard and Quick Response
PRODUCT DESCRIPTION
These Model V27 standard
spray sprinklers are
designed to produce a
hemispherical spray pat-
V2707
tern for standard commer-
cial applications. They are
vvos available with either stan-
Recessed dard or quick response
Pendent bulbs. The design incorpo-
rates state-of-the-art, heat
<> responsive, frangible glass
V - See Victaulic
10.01
bulb design (standard or
publication
V2707 for details quick response) for prompt.
V2708 precise operation.
The the cast frame is more
streamlined and attractive
V than traditional sand cast
Pendent frames. It is cast with a
V270 hex-shaped wrench boss to
V2704 allow easy tightening from
Upright
TECHNICAL SPECIFICATIONS
Models: V2703, V2704. V2707,
V2708
Style: Pendent. Upright or
Recessed Pendent
Nominal Orifice Size:
% (13 mm)
K-Factor: 5.6 imp. (8,1 Si.")
Nominal Thread Size:
'A' NPT (15 hInt)
Max. Working Pressure:
175 psi (1200 kPa)
Factory Hydrostatic Test:
100% @ 500 psi (3450 kPa)
Mm. Operating Pressure:
7 psi (48 kPa)
Temperature Rating: See
chart on page 2.
MATERIAL
SPECIFICATIONS
Upright Deflector:
Bronze per UNS C22000
Pendent Deflector:
Bronze per UNS C5 1000
Bulb: Class with glycerin solu-
tion.
Bulb Nominal Diameter:
U Standard: 5,0 mm
U Quick Response: 3.0 mm
Load Screw: Bronze per UNS
C65100
Pip Cap: Bronze per UNS
C65100
Spring: Beryllium nickel
Seal: Teflon* tape
Frame: Die cast brass 65-30
Lodgement Spring:
Stainless steel per UNS S30200
ACCESSORIES
Installation Wrench:.
U Open End: V27
U Recessed: V38. V38-3
U Socket: V27
Finishes:
U Plain brass
U Chrome plated
U White painted
U Custom painted**
U Lead**
155,200, 286SR Only:
U Wax
U Wax over lead**
For cabinets and other accesso-
ries refer to separate sheet.
NOTE: Weather resistant recessed
escutcheons available upon request
" For K-Factor fotlen pressure is mea-
sured in Bar, multiply S.I. units by
10.0.
Tellon is a registered trademark of
Dupont Co.
UL Usted for corrosion resistance in
all configurations.
VICTAULIC' IS AN ISO 9001 CERTIFIED COMPANY
Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific
Phone: 1-800-PICK-VIC (1.800-742-5842) Phone: 905-884-1444 Phone: 32.9.381-1500 Phone: 610-559-3300 Phone: 65-6235-3035
Fax: 610-250-8811 Fax: 905-884-9174 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535
e-mail:pickvic@viclauIic.com e-mail: viccartada@victaulic.com e-mail: viceuro@victaulic.be e-mail: vical@victaulic.com e-mail: vicap@victaulic.com
2544 Rev.0 8103 111 Reglsuad ltademalc of Vlctauilc 0 Copylght 2003 Vhchatllc Printed In U.S.A.
APPROVALSILUSTINGS
Nominal Approved Temperature Ratings °FI°C S 0
Orifice Size K-Factor
Inches Imperial Deflector
Model millimulets S.L* Response Type UL FM ULC NYCIMEAt CSFM §
½ 5.6 135-360 135-360 135-360 135-360 135-360
V2703 13 8.1 Standard Upright 57-182 57-182 57-182 57-182 57-182
½ 5.6 135-360 135-360 135-360 135-360 135-360
V2707 13 8,1 Standard Pendent 57-182 57-182 1 57-182 57-182 57-182
½ 5.6 Recessed Pendent 135-360 135-200 135-360 135-360 135-360
V2707 13 8.1 Standard UptoWAdjustment 57-182 57-93 57-182 57-182 57-182
½ 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8,1 Quick Upright 57-141 57 -141 57-141 557-141 57-141
½ 5.6 135-286 135-286 135-286 135-286 135-286
V2708 13 8.1 Quick Pendent 57-141 57-141 57-141 57-141 57-141
½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200
V2708 13 8.1 Quick Up tots" Adjustment 57-93 57-93 57-93 57-93 57-93
½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200
V2708 13 8.1 Quick Upto~'Adjustrnent NO 57.93 5793 5793
1 Listings and approval as 01 printing. UAII are approvea open, except ror areas aesugnarea No.
A For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.
1 MEA #62-99.E. § CSFM #7690-0531:112
RATINGS
All glass bulbs are rated for
temperatures from -67°F
(-55°C) up to those shown
in adjacent table.
Temperature - °FI°C
Sprinkler Victaulic Nominal Maximum Glass
Temperature Part Temperature Ambient Temp. Bulb
Classification Identification Rating Allowed Color
Ordinary A 135 57 100
38 Orange
Ordinary C 155
68
100
38 Red
Intermediate E 175 150
65 Yellow
Intermediate F 200 150
93 65 Green
High -' 286
141
225 -
107 Blue
Extra High I K 360
182
300
149 Purple
- 1 M Open : No Bulb
I Standard response only.
All are approved open. except for areas designated "No".
- 150165 if wax coated.
ORDERING INFORMATION
Please specify the following
when ordering: U Sprinkler Model Number U K-Factor U Sprinkler Finish
O Style U Thread Size U Escutcheon Finish
U Temperature Rating U Quantity U Wrench Model Number
Aiwaysreadand understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation
of any sprinklers.
Always wear safety glasses and foot protection.
Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products.
Installation rules, especially those governing obstruction, must be strictly followed.
W Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed.
Failure to follow these instructions could result in serious personal injury and/or property damage.
The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the
current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional
maintenance, testing, and inspection requirements that must be followed.
If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton,
Pennsylvania 18044.0031, 610-559-3300.
40.10-2
DIMENSIONS
.1W
2W (41 mm)
(60 mm)
1 M
(37 mm)
(25 mm)
Standard Pendent - V2707, V2708 Standard Upright - V2703. V2704
ri-
2 (60 mm) Max. Hole
2"(51 mm)
Mm. Hole -
Typical Ceiling Tile ,27mm)
fl'.
Finished Sixfe (30 MM)
MAXIMUM RECESS
L 2'i,
(75 mm)
MAXIMUM EXTENSION
W Adjustment
Recessed - V2707, V2708
(Drawing not to scale)
.%"(60 mm) Max. Hole
T(51 mm)
Mm. Hole
Typical Ceiling Tile
'-"i-'
Finished Surface
MAXIMUM RECESS
2W
(75 mm)
MAXIMUM EXTENSION
W" Adjustment
Recessed . V2707, V2708
(Drawing not to scale)
AVAILABLE WRENCHES
V27
Socket
V38 or V38-3
Recessed
V27
Open End
V2107, V2708 Pendent / / /
V2707, V2708 Recessed Pendent / / -
V2703. V2704 Upright - / /
40.10-3
UAC
(17 mm)
it'/l'.
(43 mm)
(24 mm)
(43 mm)
- '\\
\
SSs
lv.
3,0
8'
2.4 m
6'
1,8m
4'
1,2 m
2'
0,6 m
1
7ps1
48 kPa
15 psi
103 kPa
30 psi -------
207 kPa
uiiuuiuiuia••iu aiuuuii•ivai•
uiIi•Nh1IuIuiII
uuuu•uiui••si•
10'
3,0t
2,4
I
1.
0,1
7psi
48 kPa
15 psi
103 kPa
30 psi ------
207 We
DISTRIBUTION PATTERNS
MODELS V2707, V2708
1(5.6 STANDARD PENDENT AND RECESSED PENDENT
DISTRIBUTION PATTERNS — TRAJECTORY
2' 4' 6' 8' 10 12' 14'
0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m
MODELS v2703, V2704
K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS — TRAJECTORY
2' 4' 6' 8' 10' 12' 14' 16'
0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m 4,9m
NOTES:
I. Data shown is approximate and can vary due to differences in installation.
These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific. Victaulic Fire, Lock Automatic Sprinklers. They are
Provided as In Formation lorguidance In avoiding obstructions to sprinklers and should not he used as minimum sprinkler spacing rules For Installation. Refer to
the appropriate NFPA National Fire Code and the authorIty having jurisdiction For specific informatIon regarding obstructions. spacing limitations and area of
coverage requirements. Failure to follow these guidelines could adversely affect, the performance of the sprinkler and will void all Listings. Approvals and War-
ranties.
All patterns are symmetrical to the centerline of the waterway.
WARRANTY Refer to the Warranty section
of the current Price List or
contact Victaulic for details.
This product shall be tresiufactured by Victaulic Company. All products to be installed In accordance with current Victaulic Installation/assembly instructions.
Vlctauttc reservos the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
40.10-4