Loading...
HomeMy WebLinkAbout1525 FARADAY AVE; ; AS0501899/12/23, 2:34 PM AS050189 Permit Data City of Carlsbad Sprinkler Permit Job Address: 1525 FARADAY AV Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: Permit No: AS050189 Status: PENDING Applied 9/22/2005 Approved: Issued: PC #: Inspector: Project Title: GOOD SOURCE SOLUTIONS,#200 FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 120 0 120 0 about:blank 1/1 Models V3411 and V3412 Extended CoveragelLight Hazard (ECLH) Pendent and Recessed Pendent Standard and Quick Response many angles, reducing assembly effort. This sprin- kler is available In various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway Is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that Is most effective in controlling the fire. Coverage Extended spray coverage Is up to 400 square feet (37,2 sq. in) per NFPA 13. p taUIiC XX V34, KII2 PRODUCT DESCRIPTION These Model V34 ECLH sprinklers are designed with a larger orifice size to V3411 provide added coverage at V3412 normal light hazard operat- ing pressures. The design Incorporates state-of-the- art, heat responsive, frangi- ble glass bulb design (stan- dard or quick response) for See Victaulic prompt, precise operation Pendent publication 10.01 for details. The the cast frame Is more streamlined and attractive than traditional sand cast 4A frames. It is cast with a hex-shaped wrench boss to allow easy tightening from Recessed Pendent TECHNICAL SPECIFICATIONS Models: V341 1. V3412 Style: Extended Coverage! Light I lazard - Pendent. Recessed Pendent Nominal Orifice Size: %" (16 mm) K-Factor: 11.2 Imp. (16.2 S.1.^) Nominal Thread Size: VV NPT (20 turn) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (34 50 kPa) Mm. Operating Pressure: 5 P' (34 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Pendent Deflector: Bronze per UNS C5 1000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5,0 rum U Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Tellon5 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: U Open End: V34 U Recessed: V34 Sprinkler Finishes: U Plain brass U Chrome plated U White painted U Custom painted50 For escutcheons, cabinets and other accessories relci' to sepa- rate sheet. For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. 'Teflon is a registered trademark of Dupont Co. "UL Usted for corrosion resistance in all configurations. Exaggerated for clarity VICTAULIC@ IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-142.5842) Phone: 905-884.1444 Phone: 32-9-381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8811 Fax: 905-884-9114 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvic@victaufic.com e-mail: viccanada@victaulic.com e-mail: vlceuro@victaulic.be e-mail: vical@victaulic.com e-mail: vicap@victaulic.com i - 2552 Rev.D 5103 0 Iglsed Trademark of Vlcuullc 0 Ccpystght 21103 VtctaUtc Flirted in U.S.A. APPROVALSILISTINGS Approved Temperature Ratings * @ (Refer to notes below) Nominal Room Size - Feetlmeters K-Factor 16 X 16 18 X 18 20 X 20 Orifice Size Imperial Deflector Model lncheslmm SJ.° Response Type 49 X 49 5,5X 5,5 5,1 X 6,1 11.2 1,3,4,5-A 1,3,4,5-A 1,3,4,5-A V3411 16 16.2 Standard Pendent 2-B 2-B 2-B 11.2 Recessed Pendent 1.3.4,5-A 1.3.4,5-A 1.3,4.5-A V3411 16 16,2 Standard UptowAdjustment 2-0 2-D 2-0 V34 11 16 11.2 16.2 Standard Recessed Pendent Up 1o~' Adjustment 1,3,4.5-A 1,3,4,5-A 1,3.4.5-A 94 11.2 1,3,4,5-A 1.3,4,5-A 1.3,4,5-A V34 12 16 16.2 Quick Pendent 2-0 2-0 2-0 94 11.2 Recessed Pendent 1,3;4,5-A 1,3.4,5-A 1.3.4,5-C V3412 16 16,2 Quick UptoWAdjustment 2-E 2-E 2-E V3412 94 16 11.2 16.2 Quick Recessed Pendent Uptot4'Adjustment 1,3.4.5-A 1,3.4.5-A 1,3.4.5-C :1 Ustings and approval as of printing. Not all temperature rating combinations are Approved or Listed. Check Victaulic For specilic combinatIons. "For K-Factor wtieri pressure is measured in Bar, multiply S.I. units by 10.0. 55 Light Hazard only. NOTES Approval Temperature Rating 1- UL A- 135F (57'C). 155'F (68'C). 175'F (79'C), 200F (93'C) 2- FM B- 135'F(57'C), 155'F (68'C). 1751 (79'C) 3- ULC C -135'F (57'C). 1751 (79'C) 4-NYC/MEA1 0- 135'F (57'C), 155'F (68'C) 5- CSFM § E- 135'F (57'C) MEA #62-99-E § CSFM #7690.0531:112 RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in adjacent table. Temperature - Sprinkler Vlctaulic Glass Temperature Part Nominal Maximum Bulb Classification Identification Temperature Rating Ambient Temp. Allowed Color Ordinary A 135 57 100 38 Orange Ordinary C 15 68 10 38 Red Intermediate E 175 79 150 65 Yellow Intermediate F 200 93 150 65 Green ORDERING INFORMATION Please specify the following when ordering: U Sprinkler Model Number U K-Factor U Sprinkler Finish U Style U Thread Size U Escutcheon Finish U Temperature Rating U Quantity U Wrench Model Number Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. . 0 • Installation rules, especially those governing obstruction, must be Strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Viclaulic) is not allowed. Failure to follow these instructions could result in serious personal injury andlor property damage. The owner is responsible for maintaining the fire protection System and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610.559.3300. 40.30-2 DIMENSIONS 2W (60 mm) Max. Hole 2(5I mm) Mm Hole 2W I (64080) 1W (') I 1W (35 m) Standard Pendent V3411, V3412 1W (29 mm) y Typical Ceiling Tile i#i>f 1%" (34 mm) - Finished Surface MAXIMUM RECESS L 2VAe (75 mm) MAXIMUM EXTENSION W Adjustment Recessed - V3411, V3412 (D,azWngnoflo scale) w (18mm) (16m 11. (47 mm) 2W (60 mm) Max. Hole 2(51 mm) Mm. Hole 1W (35 mm) (24 mm) 16" (16mm) Typical Ceilng inn le d1ba 1W 1%" Finished Surface (29 mm) (47 mm) MAXIMUM RECESS (75 mm) MAXIMUM EXTENSION W Adjustment Recessed -V3411, V3412 (D'swngnc?b scale) AVAILABLE WRENCHES V34 Open End V34 Recessed Pendent Recessed Pendent ROOM SIZE SPRINKLER PERFORMANCE FLOW AND PRESSURE (MINIMUM) V3411,V3412 RDom Flow Rate End Sprinkler Pressure size GPMILPM PSIIkPa FM UL FM UL feetlm 16X16 30 30 7 7 4,9X4.9 115 115 50 50 18X18 33 33 9 9 5,5X5,5 125 125 60 60 20X20 40 40 13 13 61 X6,1 150 150 90 90 40.30 -3 '1?'II,41'1'Ii 19k. diII 1,11 r..a ISl.fl fl'lfl'J 1 i•i•uum•u•uuuu ••UU•lU•llI•L•ll I•IUIlUUUUlUILII• u•uasum•i•iiui u•uuu•uuiuuuiu 2' 4' 6' 81 10' 12' 14' 16' 18' 0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m 49m 5,5m 10' 3,0 m 8' 2,4 m 6' 1,8 m 4' 1,2 m 2- 0,6 in 0 30 GPM 113,6 1PM 33 GPM 124,9LPM 40 GPM 151,4 LPM DISTRIBUTION PATTERNS MODELS V3411, V3412 K11.2 ECLH PENDENT AND RECESSED PENDENT Minlumum Installation Spacing Response Feetlmeters V3411 -Standard 10.0 3,0 6.0 V3412-Quick NOTES: Data shown Is approximate and can vary Clue to differences In installation. These graphs Illustrate approximate trajectories. floor-wetting. and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as lnformatloti for guidance In avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules ror installation. Refer to the appropriate NFPA National Fire Code or the Authority having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect, the performance of the sprinkler and will void all Listings. Approvals and War- rant ins. All patterns are symlnelrical In ihe centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic company. All products to be installed in accordance with currant Victaulic installationlassombly instructions. Victaulic reserves tho right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.30-4 many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to VV (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heal responsive liquid. During a fire, the ambient tempera- lure rises causing the liquid in the bulb 10 expand. When the ambient temper- ature reaches the, rated temperalurc of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. taUIiC XX V27, K5.6 Models V2703, V27041, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response PRODUCT DESCRIPTION These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pat- V2707 tern for standard commer- cial applications. They are vvos available with either stan- Recessed dard or quick response Pendent bulbs. The design incorpo- rates state-of-the-art, heat <> responsive, frangible glass V - See Victaulic 10.01 bulb design (standard or publication V2707 for details quick response) for prompt. V2708 precise operation. The the cast frame is more streamlined and attractive V than traditional sand cast Pendent frames. It is cast with a V270 hex-shaped wrench boss to V2704 allow easy tightening from Upright TECHNICAL SPECIFICATIONS Models: V2703, V2704. V2707, V2708 Style: Pendent. Upright or Recessed Pendent Nominal Orifice Size: % (13 mm) K-Factor: 5.6 imp. (8,1 Si.") Nominal Thread Size: 'A' NPT (15 hInt) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS C5 1000 Bulb: Class with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5,0 mm U Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench:. U Open End: V27 U Recessed: V38. V38-3 U Socket: V27 Finishes: U Plain brass U Chrome plated U White painted U Custom painted** U Lead** 155,200, 286SR Only: U Wax U Wax over lead** For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request " For K-Factor fotlen pressure is mea- sured in Bar, multiply S.I. units by 10.0. Tellon is a registered trademark of Dupont Co. UL Usted for corrosion resistance in all configurations. VICTAULIC' IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1.800-742-5842) Phone: 905-884-1444 Phone: 32.9.381-1500 Phone: 610-559-3300 Phone: 65-6235-3035 Fax: 610-250-8811 Fax: 905-884-9174 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-6235-0535 e-mail:pickvic@viclauIic.com e-mail: viccartada@victaulic.com e-mail: viceuro@victaulic.be e-mail: vical@victaulic.com e-mail: vicap@victaulic.com 2544 Rev.0 8103 111 Reglsuad ltademalc of Vlctauilc 0 Copylght 2003 Vhchatllc Printed In U.S.A. APPROVALSILUSTINGS Nominal Approved Temperature Ratings °FI°C S 0 Orifice Size K-Factor Inches Imperial Deflector Model millimulets S.L* Response Type UL FM ULC NYCIMEAt CSFM § ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2703 13 8.1 Standard Upright 57-182 57-182 57-182 57-182 57-182 ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2707 13 8,1 Standard Pendent 57-182 57-182 1 57-182 57-182 57-182 ½ 5.6 Recessed Pendent 135-360 135-200 135-360 135-360 135-360 V2707 13 8.1 Standard UptoWAdjustment 57-182 57-93 57-182 57-182 57-182 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8,1 Quick Upright 57-141 57 -141 57-141 557-141 57-141 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2708 13 8.1 Quick Pendent 57-141 57-141 57-141 57-141 57-141 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200 V2708 13 8.1 Quick Up tots" Adjustment 57-93 57-93 57-93 57-93 57-93 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 V2708 13 8.1 Quick Upto~'Adjustrnent NO 57.93 5793 5793 1 Listings and approval as 01 printing. UAII are approvea open, except ror areas aesugnarea No. A For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. 1 MEA #62-99.E. § CSFM #7690-0531:112 RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in adjacent table. Temperature - °FI°C Sprinkler Victaulic Nominal Maximum Glass Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary C 155 68 100 38 Red Intermediate E 175 150 65 Yellow Intermediate F 200 150 93 65 Green High -' 286 141 225 - 107 Blue Extra High I K 360 182 300 149 Purple - 1 M Open : No Bulb I Standard response only. All are approved open. except for areas designated "No". - 150165 if wax coated. ORDERING INFORMATION Please specify the following when ordering: U Sprinkler Model Number U K-Factor U Sprinkler Finish O Style U Thread Size U Escutcheon Finish U Temperature Rating U Quantity U Wrench Model Number Aiwaysreadand understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. W Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044.0031, 610-559-3300. 40.10-2 DIMENSIONS .1W 2W (41 mm) (60 mm) 1 M (37 mm) (25 mm) Standard Pendent - V2707, V2708 Standard Upright - V2703. V2704 ri- 2 (60 mm) Max. Hole 2"(51 mm) Mm. Hole - Typical Ceiling Tile ,27mm) fl'. Finished Sixfe (30 MM) MAXIMUM RECESS L 2'i, (75 mm) MAXIMUM EXTENSION W Adjustment Recessed - V2707, V2708 (Drawing not to scale) .%"(60 mm) Max. Hole T(51 mm) Mm. Hole Typical Ceiling Tile '-"i-' Finished Surface MAXIMUM RECESS 2W (75 mm) MAXIMUM EXTENSION W" Adjustment Recessed . V2707, V2708 (Drawing not to scale) AVAILABLE WRENCHES V27 Socket V38 or V38-3 Recessed V27 Open End V2107, V2708 Pendent / / / V2707, V2708 Recessed Pendent / / - V2703. V2704 Upright - / / 40.10-3 UAC (17 mm) it'/l'. (43 mm) (24 mm) (43 mm) - '\\ \ SSs lv. 3,0 8' 2.4 m 6' 1,8m 4' 1,2 m 2' 0,6 m 1 7ps1 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa uiiuuiuiuia••iu aiuuuii•ivai• uiIi•Nh1IuIuiII uuuu•uiui••si• 10' 3,0t 2,4 I 1. 0,1 7psi 48 kPa 15 psi 103 kPa 30 psi ------ 207 We DISTRIBUTION PATTERNS MODELS V2707, V2708 1(5.6 STANDARD PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS — TRAJECTORY 2' 4' 6' 8' 10 12' 14' 0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m MODELS v2703, V2704 K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS — TRAJECTORY 2' 4' 6' 8' 10' 12' 14' 16' 0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m 4,9m NOTES: I. Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific. Victaulic Fire, Lock Automatic Sprinklers. They are Provided as In Formation lorguidance In avoiding obstructions to sprinklers and should not he used as minimum sprinkler spacing rules For Installation. Refer to the appropriate NFPA National Fire Code and the authorIty having jurisdiction For specific informatIon regarding obstructions. spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect, the performance of the sprinkler and will void all Listings. Approvals and War- ranties. All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be tresiufactured by Victaulic Company. All products to be installed In accordance with current Victaulic Installation/assembly instructions. Vlctauttc reservos the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.10-4