Loading...
HomeMy WebLinkAbout2784 GATEWAY RD; ; AS1200959/12/23, 2:38 PM AS120095 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2784 GATEWAY RD Permit Type: SPRINK Parcel No: 2133001204 Lot #: 0 Reference No.: PC #: Permit No: A5120095 Status: APPROVED Applied 8/23/2012 Approved: 9/6/2012 Issued: 9/6/2012 Inspector: Project Title: ALAN RICH & ASSOCIATES T.I. Applicant: TOTAL FIRE PROTECTION, INC. STE. 244 1611-AS. MELROSE DR. VISTA, CA 760-525-4329 Owner: KELLY CAPITAL GROUP INC 406 9TH AVE #309 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 262 0 • 262 0 about:blank 1/1 MATERIAL DATA SUBMITTAL Alan Rich & Associates 2784 Gateway Road Carlsbad CA, 92009 'age * Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe 3-10 Fittings Tyco Ductile Iron Fittings 11-12 Mechanical Tee Tyco Fig 40-5 Strap Tee 13-19 Sprinkler Tyco TY-FRB Recessed Sprinkler 20 Hanger Afcon Fig. 300 Ring Hanger 21 Hanger Afcon Fig 655 All Thread Rod 22 Attachment Sammy Wood Vertical Mount Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohnc©gmail.com Asigovqs~F DynamThread 0 Full Line Sch-40 Replacement Dyna-Thread' offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. . The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike ligbtwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA- 13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. WI. WI. (H2O Filled) Pa/ Wistift (21') WIJLIII (24') Wljtlft (25' In; mm In; mm Lbs/Ft; Kg/rn Lbs/F?; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 1056 1W 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3.4 4.79 44 959 1097 114 2' 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 16100 S. Lathrop' Harvey, IL 60426 tqco/Flow Control c1IiecJ 11350 Norcom Rd. Philadelphia, PA 19154 TUBE& CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: 1 (800) 882-5543 Fax 708-339-1806 83-3 Submittal Data Sheet Dyna-Thread® Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR1 .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Stamp Here Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40IDyna.Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula 'ABF". Specifications NPS Nominal I.D. M. WI. (1120 Filled) PcW Wlstllt (211) WULIII (24') Wbtift (25' In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 1051 1 /4' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1½' 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured U. (.j) with Exterior galvanized coating. BIT is manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: S3-4 \.,•_J tqCD Fire & Building liProducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The Tyco* Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Usted and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI 131.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there Is about one turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects In mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from data of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in acÔordance with applicable 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made In lieu of any and all other warranties, ex- cress or imolied. including warranties of merchantability and fitness for a carticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. tregistered trademark of E. I. du Pont de Nemours and Company or Its affiliates. TFPI7IO Page 2 of 10 TFPI7IO cc FIGURE 811 FIGURE 813 90° ELBOW 45° ELBOW Nominal Pipe Size Figure 811 Figure 813 ANSI A B Appm A B Approx. Inches Inches Inches WeigI t Part Inches Inches Weight Part ON (mm) (mm) Lb s. Number (mm) (mm) Lbs. Number (kg) - (kg) 1/2 1.13 0.56 0.24 86206 0.88 0.38 0.22 86780 DN15 (28,7) (14,2) (0.11) (22,4) (9,7) (0,09) 3/4 1.31 0.75 0.40 86205 1.00 0.44 0.33 86781 DN20 (33,3) (1910) (0,18) - (25,4) (11,2) (0,15) 1 1.50 0.81 0.64 86200 1.13 0.81 0.48 86280 DN25 (38,1) (20,6) (0,29) - (28,7) (20,6) (0,21) 1-1/4 1.75 1.06 0.95 86201 1.31 0.63 0.73 86281 DN32 (44,5) (26,9) (0,43) - (33,3) (16,0) (0,33) 1-1/2 1.94 1.19 1.24 86202 1.44 0.69 0.93 86282 DN40 (49,3) (30,2) (0156) - (36,6) (17,5) (0,42) 2 0N50 2.25 (57,1) 1.50 (38,1) 1.74 (0,79) - 86203 1.68 (42,7) 0.94 (23,9) 1.55 (0,70) 86283 ______ 2-1/2 DN65 2.69 (68,3) 1.56 (39,6) 3.28 (1,49)! 86204 1.94 T(725,4) (49,3) 2.70 (1,22) 86782 I TABLE NOMINAL DIMENSIONS FIGURES 811 & 813 IFPI7I0 I Page 3of 10 0 TFPI7IO Page 5 of 10 FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING Nominal Pipe Figure 814 Figure 818 Size ANSI Inches A B Appro. weight Part A B Approx. Weight Part ON Inches Inches Lbs. Number Inches Inches Lbs. Number (mm) (mm) - (mm) (mm) (kg) 112 1.13 0.56 0.33 1 86340 1.38 0.31 0.18 72779 DN15 (28,7) (14,2) (0,15) - (35,1) (Z9) (0108) 3/4 1.31 0.75 0.50 86341 1.63 0.56 0.26 72778 DN20 (33,3) (19,0) (0,23) (41,4) (14,0) (0,11) 1 1.50 0.81 0.85 86230 1.75 0.38 0.44 72755 DN25 (38.1) (20,6) (0.38) - (44,4) (9,7) (0,20) 1-1/4 1.75 1.06 1.30 86231 2.00 0.56 0.54 72754 DN32 (44,4) (26,9) (0,59) - (50,8) (1410) (0,24) 1-1/2 1.94 1.19 1.63 86232 2.19 0.75 0.71 72753 DN40 (49,3) (30,2) (0,74) - (55,6) (19,0) (0,32) 2 2.25 1.50 2.63 86233 2.63 1.13 1.15 72752 0N50 (5711) (38,1) (1119) - (66,8) (28,7) (0,52) 2-1/2 2.69 1.56 4.55 86234 3.00 0.75 29 72758 DN65 (68,3) (39,6) (2,06) - (76,2) (19,0) (1,04) I TABLE NOMINAL DIMENSIONS FIGURES 814 & 818 TFPI7IO Page 6 of 10 0' FIGURE 815 EDUCING TEE Nominal Pipe Size Figure 815 A B C D E F Approx. ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part DN (mm) (mm) (mm) (mm) (mm) Lbs. Number (kg) 3/4x3/4x 1/2 1.19 1.19 1.25 0.63 0.63 0.69 0.46 86235 020*20 x 15 (30.2) (30,2) (31.8) (16.0) (16.0) (17.5) (0.21) 3/4 x 3/4 xl 1.44 1.44 1.38 0.88 0.88 0.69 0.68 86755 DN20x20x25 (36.6) (36.6) (35.1) (22.4) (22.4) (17.5) (0.31) 1 x 1/2* 1 1.50 1.38 1.50 0.81 0.81 0.81 0.70 86236 DN25x15x25 (38.1) (35.1) p38.11 (20.6) (20.6) (20.6) (0.32) I *3/4 x 1/2 1.25 1.19 11.38 0.56 0.63 0.81 0.63 86756 DN25x20x15 (31.8) (30.2) (35,1) (14.2) (16.0) (20.6) (0.28) 1 *3/4 x 3/4 1.38 1.31 11.44 0.69 0.75 0.88 0.68 86757 0N25 x 20*20 (35.1) (33.3) (36.6) (17.5) (19.0) (22.4) (0.31) 1 *3/4*1 1.50 1.44 1.50 0.81 0.88 0.81 0.77 86237 DN25 x 20 x 25 (38.1) (36.6) (38.1) (20.6) (22.4) (20.6) (0.35) I x x 112 1.25 1.25 11.38 0.56 0.56 0.81 0.66 86238 DN25 x 25 x 15 (31.8) (31.8) 35.1) (14.3) (14.3) (20.6) (0,30) 1 x x 3/4 1.38 1.38 1.44 0.69 0.69 0.88 0.73 86239 DN25x25x20 (35.1) (35.1) (36.6) (17.5) (17.5) (22,4) (0.33) lxix 1-1/4 1.69 1.69 1.56 1.00 1.00 0.88 0.97 86240 DN25 *25 x 32 (42.9) (42.9) (39.6) (25.4) (25.4) (22.4) (0.44) I x x 1-1/2 1.81 1.81 11.63 1.13 1.13 0.88 1.14 DN25 x 25*40 (46.0) (46.0) (41.4) (28.6) (28.6) (22.4) (0.52) 86241 1-1/4x1x1/2 1.94 1.25 i 1.56 0.63 0.56 1.00 0.81 86242 0N32 x 25*15 (49.2) (31.8) (39.6) (15.9) (14,3) (25.4) (0.37) 1-1/4x 1*3/4 1.44 1.38 11.62 0.75 0.69 1.06 0.90 86243 032*25 x 20 (36.6) (35.1) (41.2) (19.0) (17.5) (27.0) (0.41) 1-1/4 x I *1 1.56 1.50 11.69 0.88 0.81 1.00 1.03 88244 DN32 *25 x 25 (39.6) (38.1) (42.9)L22-4) (20.6) (25.4) (0.47) 1-1/4x1x1-114 1.75 1.69 11.75 1.06 1.00 1.06 1.10 86245 02*25*32 (44.4) (42.9) 144,4) (27.0) (25.4) (27.0) (0.50) 1-1/4x1 *1-1/2 1.88 1.81 1. 81 1.19 1.13 1.06 1.43 86246 0N32 *25 x 40 (47.6) (46.0) (46.0) (30.1) (28.6) (27.0) (0.65) 1-1/4*1-1/4*1/2 1.38 1.38 1.56 0.69 0.69 1.00 0.87 DN32 *32* 15 (35.1) (35.1) (39.6) (17.5) (17.5) (25.4) (0.39) 86247 14/4x1-114x3/4 1.44 1.44 1.63 0.75 0.75 1.06 0.96 0N32 x32 x20 (36,6) (36.6) (41.4) (19.0) (19.0) (27.0) (0.43) 86248 1-1/4x1-1/4x1 1.56 1.56 1.69 0.88 0.88 1.00 1.10 DN32 *32 x 25 (39.6) (39,6) 142.9 (22.4) (22.4) (25,4) (0.50) 86249 1-114x1-1/4 x1-1/2 1.88 1.88 1.81 1.81 1.81 1.06 1.50 032*32*40 (47.6) (47.6) (46.0) (46.0) (46,0) (27,0) (0.68) 86250 1-1/4* 1-1/4x2 2.13 2.13 2.00 1.44 1.44 1.13 2.00 01432 x 32*50 (54.1) (54.1) E50.8) (36.6) (36.6) (28.6) (0.91) 86251 14/2 x x 1/2 1.44 1.31 1.69 0.69 0.63 1.13 0.97 01440*25*15 (36.6) (33.3) t42.9) (17.5) (15.9) (28.6) (0.44) 86252 1-1/2x 1 x314 1.50 1.38 1.75 0.75 0.69 1.19 1.14 01440 x 25 x 20 (38.1) (35.1) (44.4) (19.0) (17.5) (30.2) (0.52) 86253 1-1/2* 1 x 1.63 1.50 1.81 0.88 0.81 1.13 1.14 01440 x 25 x 25 (41.4) (38.1) (46.0) (22.4) (20.6) (28.7) (0.52) 86254 1-1/2*1 x 1-1/2 1.94 1.81 1.94 1.19 1.13 1.19 1.52 0N40 x 25*40 (49.3) (46.0) (49.2) (30.2) (28.6) (30.2) (0.69) 86255 TABLE 5(1 0F2) NOMINAL DIMENSIONS FIGURE 815 VA Page 7 of 10 TFPI7IO FIGURE 815 EDUCING TEE Nominal Pipe Size Figure 815 A B C 0 E F ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part ON (mm) (mm) Imm) (mm) (mm) (mm)Lbs. Number (kg) 1-1/2x1-114x1/2 1.44 1.31 1.69 0.69 0.63 1.13 1.03 DN4O *32*15 (36.6) (33.3) 142.9) (17.5) (16.0) (28.7) (0.47) 86257 14/2 x 1-1/4*3/4 1.50 1.44 11.75 0.75 0.75 1.19 hO DN40x32x20 (38.1) (36.6) (44.5) (19.0) (19,0) (30.1) (0.50) 86258 1-1/2x1-1/4x1 1.63 1.56 t1.81 0.88 0.88 1.13 1.31 040*32 x 25 (41.4) (39.7) (46.0) (22.4) (22.4) (28.7) (0.59) 86259 1-1/2* 1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 194 DN40 *32 x 50 (55.6) (54.1) - 50.81 (36.6) (36.6) (57.1) (0.88) 86260 14/2x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 DN40x40x15 (36.6) (36.6) 42.911 (17.5) (17.5) 1 (28.7) (0.52) 66261 1-1/2x1-1/2x3/4 1.50 1.50 1.75 0.75 0.75 1.19 123 DN4Ox40x20 (38.1) (38.1) - AL (19.0) (19.0) (30.1) (0.56) 86262 14/2 x 1-1/2* 1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 DW40 *40 x 25 (41.2) (41.2) - 60L (22.4) (22.4) (28.7) (0.62) 86263 14/2 x 14/2*1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 DN40 x 40 x 32 (46.0) (46.0) -Efi_(27.0) (27.0) (30.1) (0.68) 86264 1-1/2x1-112x2 2.19 2.19 '2.00 1.44 1.44 1.25 2.00 DN40x40x50 (55.5) (55.5) '50.8) (36.6) (36.6) (31.7) ((X91) 86265 2x1 *2 2.25 2.00 1,2.25 1.50 1.31 1.50 2.18 DN50 *25 x 50 (57.2) (50.8) 57.2) (38.1) (33.3) (38.1) (0.99) 86266 2 x 1-1/4 x 2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 DN50 *32*50 (57.2) (54.1) t57.2) (38.1) (36.6) (38.1) (1.05) 86267 2*1-1/2*1/2 1.50 1.44 1.88 0.75 0.69 1.31 1. 8626850 DN50 x 40*15 (38.1) (36.6) (47.8) (18.0) (17.5) (33.3) (0.68) 2x1-1/2x314 1.63 1.50 11.94 0.88 0.75 1.38 1.61 DNSO x 40 x 20 (41.4) (38.1) 49.3) (22.4) (19.0) (35.0) (0.73) 86269 2x1-1/2x 1 1.75 1.63 2.00 1.00 0.88 1.31 1.65 DN50 x 40 x 25 (44.5) (41.4) i50.81 (25.4) (22.4) (33.3) (0.75) 86270 2 x 14/2 x 1-1/2 2.06 1.94 2.19 1.31 1.19 1.44 2.03 DN5O *40 x 40 (52.4) (49.2) 55.51 (33.3) (30.2) (36.6) (0.92) 86272 2*1-1/2*2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 DN50x40x50 (57.1) (55.5) (63.5) (38.1) (36.6) (38.1) (1.07) 86273 2*2*1/2 1.50 1.50 1.88 0.75 0.75 1.31 1.50 DN50 *50 x 15 (38.1) (38.1) (47.8) (19.0) (19.0) (33.3) (0.68) 86222 2*2*3/4 1.63 1.63 1.94 0.88 0.88 1.38 1.87 DN50 *50*20 (41.4) (41.4) 49.3) (22.4) (22.4) (35.0) (0.76) 86223 2x2 xi 1.75 1.75 2.00 1.00 1.00 1.31 1.91 DN50 x 50*25 (44.5) (44.5) E50.8) (25.4) (25.4) (33.3) (0.86) 86224 2*2*1-1/4 1.88 1.88 2.13 1.13 1.13 1.44 2.05 DN50 x 50*32 (47.8) (47.8) 54.11 (28.7) (28.7) (36.8) (0.93) 86225 2x2x14/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 ON50x50x40 (50.8) (50.8) (31.8) (31.8) (38.1) (0.96) 86226 2*2*2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3.67 DN50 * 50*65 (66.8) (66.8) (60.5) (44.5) (47.8) (36.6) (1.66) 86227 2-1/2x2x3/4 1.75 1.63 p.31 0.63 0.88 1.75 2.22 DN65 *50 x 20 (44.5) (41.4) (58.7) (15.9) (22.4) (44.5) (1.01) 86274 TALE5 (2 0F2) NOMINAL DIMENSIONS FIGURE 815 Page 8 of 10 TFPI7IO FIGURE 820 FIGURE 830 FIGURE 719 CAP SS SEAT UNION PLUG Nominal Pipe Size Figure 820 Figure 830 Figure 719 ANSI A Approx. I B Approx. A Approx. Inches Inches Weight Part mci as Inches Weight Part Inches Weight Part ON (mm) Lbs. Number (m i) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 1/2 DN15 0.88 (22,4) 0.15 (0.06) 72776 1.88 (47,8) 0.81 (20,6) 0.47 (0,21) 86207 0.94 (23,9) 0.10 (0,04) 86292 3/4 DN20 1.00 (25,4) 0.22 (0110) 72777 2X0 (508) 0.94 (23,9) 0.66 (0.30) 86275 1.13 (28,7) 0.18 (0,08) 86293 1 1.18 0.33 72824 2.1 0.81 1.08 86276 1.25 0.28 86294 DN25 (30,0) (0,15) (556) (20,6) (0,49) (31,7) (0,13) .14/4 1.31 0.54 . 72756 2 i0 1.06 1.54 86277 1.38 0.50 86295 0N32 (33,3) (0,24) (635) (26,9) (0.70) (35,1) (0,23) 1-1/2 1.38 0.68 72822 2.3 1.19 2.03 86278 1.44 0.70 86296 DN4O (35,1) (0,31) (668) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 DN50 (38,1) (0,43) (795) (41,4) (1,43) (38,1) (0,41) 2-1/2 1.75 1.80 - [ - - - - - - DN65 (44,5) (0,82) 72825 1 TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 TFPI7IO Page 9 of 10 1 L=L fl B! IA L1L,- FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B ANSI inches Inches Weight Part Inchs Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mi ) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - - DN15 x 15 (3811) (0109) 1/2x1/2 2.00 0.27 12980 - - - - - - - 0N15 x 15 (50.8) (0.12) 3/4 x 3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (38,1) (0110) 3/4 x 3/4 2.00 0.31 73982 DN20x20 (50,8) (0,14) - - - - - - - 3/4 x 1/2 1.75 0.69 0.38 86772 DN20 x 15 - - - - (43,2) (17,5) (0,17) I x1/2 1.0 0.22 72726 1.69 0.50 0.38 86228 DN25 x 15 - - - .J' L (0,10) (42,9) (12,7) (0,17) I x3/4 1.( 0.18 72762 1.75 0.50 0.53 86229 DN25 x 20 - - - (26, L (0,08) (43,2) (12,7) (0,24) 1-114x1 1.1 0.31 72763 - - - 0N32 x 25 - - - (30,4 (0,14) 1-1/2 x 1.2k 053 72757 - - - - DN40 x 25 (31,) (0,24) 1-1/2x1-1/4 1.2 0.35 72764 - - - - DN40x32 - - - (31,) (0,10) 2x1 DNSO x 25 - - - 1.36 (35.1 0.75 72759 - (0,34) - - - 2x1-1/4 1.38 0.69 72761 - - - - DN50x32 - - - (35. (0,31) 2x1-l/2 - - - 1.38 0.62 72775 - - - - DN5O x 40 (35,) (0,28) I TABLE? NOMINAL DIMENSIONS FIGURE 825,827 & 816 (B Pressure Rating and Listing/Approval Information tyCe IF/re & / Produ Technical Services: Tel: (800) 381-9312/ Fax: (800) -5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General Description The Figure40-5 Strap is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with lull lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, aswellaswiththeapplicablestandards of the National Fire Protection Association, in addition to the standards of any otherautho rities ha ving jurisdiction. Failure to do so may impair the pertonnance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershould be contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, LJLC, and VdS; See Fire Protection Submittal Sheet for exact Listing / Approval information. Housing: Ductile iron conforming to ASTM A-536,l Grade 65-45-12 Protective Coatings: 'Clear rust inhibitive coating 'Zinc electroliated conforming to ASTM 8-633, Type Ill Service 2 (optional) U-Bolt: Carbon Steel conforming to ASTM A-307 Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307,1 Grade A, Zinc electroplated Gasket: (specify when ordering) 'Grade 'E" EDM green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing a order, indicate the full product name. Please spécifythe quantity, figure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe 1.S., Canada, and internationally, through a netwqrk of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care The owner Is responsible for the inspection, testing, and maintenance of their fire protection system and devices In accordance with the applicablestandards of the National Fire Protection Association (e.gt, NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractoror product manufacturer should be contted relative to any questions. Any impairment must be Immediately corrected. It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service, Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid torand property installed and maintained under normal use and service. This warranty will expire ten (10)years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwithTyco Fire Products orfor products and components which have been subject to misuse, improperinstallation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any otherAuthoritiesHaving Jurisdiction. Materials found byTyco Fire Products tobe detective shall be either repaired orreplaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit,anyotherobiigafloninconnectionwfth the sale of products or parts of products. Tyco Fire Prnductsshalnotberesponsilleforsptinklersystem designerrorsorkiaccurateorincompletelnfomiation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEOLJENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER1YCORREPRODUCTSWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALLTYCOAREPRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. 11ER WNIYIEMAIEWINGIIh' ANYAML DuEl WA4N1BPF INI IMPLIED. INWIDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A (B TFPI 720 Page 1 of 2 SePtember 2004 Pipe Nominal Dimensions Hole Net Size Size Wt. A B C 0 Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 11/4" x 1/21' 2.00 1.50 3.50 1.20 1/io 0.84 50.8 38.1 88.9 30.5 1 30.2 0.4 1/41' x 3/41' 2.00 1.50 3.50 1.20 1/io 0.88 50.8 38.1 1 88.9 30.5 30.2 0.4 1'/41' X i' 2.31 1.68 3.50 1.20 Wie 1.13 58.7 42.7 88.9 30.5 30.2 0.5 1'/? , 1/fl 2.12 1.62 3.50 1.32 1/l6 0.84 53.8 41.1 88.9 33.5 30.2 0.4 11/20 2.12 1.62 3.50 1.32 13M 0.88 53.8 41.1 88.9 33.5 30.2 0.4 1'/2" x 1" 2.43 1.80 3.50 1.32 i/16 1.13 61.7 45.7 88.9 33.5 30.2 1 0.5 21' x Ile 2.36 1.86 3.74 1.55 1/i 0.88 59.9 47.2 95.0 39.4 30.2 0.4 20 x 3/U 2.36 1.86 3.74 1.55 1/l6 0.95 59.9 472 95.0 39.4 1 30.2 0.4 21' x i 2.67 2.04 3.74 1.55 13/is 1.16 67.8 51.8 95.0 39.4 30.2 0.5 2V2" X1/21' 2.61 2.11 4.25 1.80 0.90 66.3 . 53.6 108.0 45.7 30.2 0.4 21/21' X3/4' 2.61 2.11 4.25 1.80 1/l6 0.99 21/21' x 1 2.92 2.29 4.25 1.80 1/16 1.21 74.2 58.2 108.0 45.7 1 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) l'I41'X 10 8 1'/2"X 1" 6 2x11' 6 2Wx 11' 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2 of 2 TFP172O 40.5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. General Notes: Ills the Designer's responsibility to select produ that pressure ratings and performance data is not exceeded. instructions (11-11000). Never remove any piping component rst depressurizing and draining the system. Material and go for the specific application. suitable for the Intended service and to ensure ways read and understand the installation correct or modify any piping deficiencies without st selection should be verified lobe compatible t'T1t TYCO FIRE PRODUCTS, 451 North Cannon Avenue, LansdaIe,Pennsylvania 19946 Printed U.S.A. tqC0 Fire & Building I,Produc4 Technical Services: Tel: (800) 381-9312/ Fax: 791-5500 Series TY-FRB - 28, 4.2, 5.6, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standrd Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendant position, or a two-piece Style 20(1/2 inch NPT)or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. tamed when exposed to corrosive at- mospheres. dthough corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approal agencies, the testing is not representative of all possible cor- rosive atmo4pheres. Consequently, it is recommerded that the end user be consulted with respect to the suitability of these comings for any given corro- sive environinent. The effects of ambi- ent temperture, concentration of chemicals, apd gas/chemical velocity, should be cOnsidered, as a minimum, along with I corrosive nature of the chemical to Y rhich the sprinklers will be exposed. An intermed ate level versions of the Series TY-F RB Pendent Sprinklers are detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained n compliance with this document, a well as with the applica- ble standard of the National Fire Pro- tection Association, in addition to the standards ofany other authorities hay- ingjurisdictkn. Failure to do so may impair the performance of these de- vices. Model/Sprinkler Identification Corrosion resistant coatings, where The owner is responsible for maintain- applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler manufacturer should be contacted IMPORTANT with any questions. Always refer to Technical Data Sheet TFP 700 for the INSTALLER WARNING" that provides cautions stallation can permanently damage with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- nents and cause the sprinkler to fail a sprinkler system or its compo- to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 AUGUST, 2007 Numbers TVII3I - Upright 2.8K, 1I2"NPT 1Y1231 - Pendent 2.8K, 112"NPT 1Y2131 - Upright 4.21K, 112"NPT TY2231 - Pendant 4.2K. 112"NPT ITY3131- Upright 5.6K, 1/2NPT ITY3231- Pendant 5.6K. 112"NPT 1Y4131 - Upright 8.0K, 3/4"NPT 1V4231 - Pendent 8.0K, 314"NPT TV4831- Upright 8.0K, 112"NPT 1Y4931- Pendant 8.0K, 112"NPT TFPI7B 13 I 1-1/2" (38.1 mm) SSP DEFLECTOR * PENDENT 2-718" (73,0 RECESSED NWRENCH FLATS it DIA. I - Frame 3-Sealing 4-Bulb 2- Button Assembly 1 5-Compression 6 TFPI7I Page 3 of 10 ESCUTCHEON PLATE SEATING SURFACE NPT (11,1 mm) 10 or 20 sSU* DEFLECTOR r 7/16" I (11,1 mm) I NOMINAL I MAKE-IN 2-3/16° to — I , (55,6 mm) 1/2"NPT t UPRIGHT CROSS SECTION Temperature rating is Indicated on deflector or adjacent LI orifice seat on frame. FIGURE 3 QUICK RESPONSE SERIES TY-FRB HT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 TOR, 1/2 INCH NPT ESCUTCHEON 112" (12.7 mm) PLATE SEATING 314" NOMINAL SURFACE NPT MAKE-IN T_ _ 2-5/16" (58,7 mm) I 1-9/16" I (39,7 mm) I SSP DEFLECTOR* I---- 2-718" PENDENT RECS 300r40 SSED CHEON DEFLECTOR 1 mm lt;112" NAL MAKE-IN DIA. v'iJ IDENT CROSS SECTION I 2-1/4" t (57,2 mm) 3/4" NPT UPRIGHT I -Frame 3-Sealing _.1 Bulb 6 1 Deflector 2- Button Assembly' 5-Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 4 RESPONSE SERIES TY-FRB UPRIGHT (TY4I 8.0 K-FACTOR. 314 AND PENDENT (TY4231) SPRINKLERS H NPT 8 Page 4 of 10 TFPI7I 7!16(11,1 mm) 1/2 NC MINAL SSU NPT M MME -IN DEFLECTOR t a rr2-1I4 (57,2 mm) 1-9/16" g 1W I (39,7 mm)F TS CROSS UPRIGHT SECTION 4 1-Frame 2- Button 3-Sealing Assembly - Compression Screw 6- * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 5 RESPONSE SERIES TY-FRB UPTh Y4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FA 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/ps1112 (40,3 LPM/barll2) K = 4.2 GPM/ps11/2 (60,5 LPMIbarlI2) K = 5.6 GPM/psill2 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/barll2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel wlTeflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Opertion The glass Bilb contains a fluid which expands whefl exposed to heat. When the rated terrperature is reached, the fluid expands sufficiently to shatter the glass Bulb, jllowing the sprinkler to activate and water to flow. The Series Ttt'-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirments of FM's Loss Pre- vention Data Sheets). Only the Style 10, 20, 30,o 40 Recessed Escutch- eon, as applipable, is to be used for recessed Den, dent installations. E Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K I TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME I PLATED WHITE""" POLYESTER LEAD COATED 5.8 1/2" PENDENT (TY3231) and 135°F1570C Orange 1,2,3,4,5,6,7 1,2,3,5 155°F/68°C Red J 1750F179°C Yellow UPRIGHT (TY3131) 200°F193"C Green 286"F/141"C Blue NPT RECESSED PENDENT (1Y3231)" Figure 10 1350171570C Orange 1,2,4.5 N/A 155"F!68°C Red1 __ 175"F179"C Yellow 200°F193°C Green 135"F157°C Orange 1. 2, 3, 4,5 N/A RECESSED PENDENT (rY3231)- Figure 11 155°F!88"C Red 175°F/79"C Yellow 200°F/93"C Green 8.0 3/4" PENDENT (TY4231) and UPRIGHT (TY4131) 135017!570C Orange 1,2, 3,4,5, 6,7 1,2,5 155°F/68°C Red 175"F/79°C Yellow 200°F/93"C Green 286'F/141"C Blue NPT 135"F!57°C Green 1,2,4,5 NIA RECESSED PENDENT (TY4231)" Figure 12 1550F1680C Orange 175"F!79'C Red 200"F193°C Yellow 1350F157"C Orange 1,2,3.4.5 N/A RECESSED PENDENT CTY4231 Figure 13 155"F/68°C Red 1750F179"C Yellow 200°F1930C Green 8.0 112" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/570C Orange 1,2,4,5,6 1,2,5 1550F/68"C Red 175"F179°C Yellow 200F/93"C Green 286F!141'C Blue NOTES: listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use In Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Rer. No. 007k104) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10(1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2' NPT) or Style 30(3/4' NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 16AN0 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED I POLYESTER I COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) NIA NPT RECESSED PENDENT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 314" RECESSED PENDENT NPT (1Y4231) PENDENT (TY3231) and 250 PSI (17.2 BAR) 175 PSI (12,1 BAR) 5.6 112 NPT OR 175 PSI (12,1 BAR) (SEE NOTE 1 [ UPRIGHT (TY3131) RECESSED PENDENT (TY3231) - PENDENT(TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3M" RECESSED PENDENT NPT (TY4231) N/A 80 PENDENT(TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TV4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, 'Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing Instructions: NOTES Do not Install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 inch (2,4 mm) for the 286°F/14 1°C temperature ratings. A leak tight 112 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 Inch NPT sprinkler joint should be ob- tamed with a torque of 10 to 20 ftlbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler Inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendant and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand lighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed TFPI7I - 2.7/8" DIA. 5/80/4" (73,0 mm) 314"(19.1 mm (15,916.4 mm) - 2-1/4" DIA. j 114' (6,4 FACE OF (57,2 mm) M TING SPRINKLER PLATE FITTING / 1/B" I - (3,2 mm) 1 _ MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4" (19.1 mm) FIGURE 10 RIES TY-FRB RECESSED PENDENT WIT TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/821/4" (13,0 mm) 314"(19.1 mm) (15,916.4 mm) 2.1/4" DIA. i 1/4" (6,4 7 1 (57,2 mm) FACE OF MOU ING SPRINKLER TE FITTING / . 1/8" I - (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16"(20.6 mm) FIGURE 12 S IES TY-FRB RECESSED PENDENT WIT 0-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 2-7/8" DIA. - (73,0 mm) 1/2±1/8" 1/2" 12,7m (12,7±3,2 mm) 2-1/4" DIA. j 1/4'(6.4 m) FACE OF (57,2 mm) M TING SPRINKLER PLATE FITTING I 1/8" 1 (3,2 mm) T_\) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY.FRB 1" (25,4 mm) FIGURE 11 RIES TY-FRB RECESSED PENDENT WI TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73.0 mm) 1/2"(12.7 mm) (12,7±3.2 mm) 2-1/4' DIA. _..j 1/4" (6.4 (57.2 mm) FACE OF MO TING SPRINKLER LATE FITTING 1/8' I - (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY.FRB 1-1116"(27,0 mm) FIGURE 13 RIES TY-FRB RECESSED PENDENT WIT TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3M INCH NPT plated, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual Inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 112' NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH lacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. 8 Page 10 of 10 TFPI7I P/N 57 - XXX - X - XXX I MODEUSIN I 1 1 4 3 I _L_ 135 155 175 200 RATING SPRINKLER 330 2.8K UPRIGHT (lI2NPT) TY1I3I 135F!57C 331 2.8K PENDENT (1!2'NPT) TY1231 NATURAL BRASS 155°F1680C 340 4.2K UPRIGHT (112"NPT) TY2131 WHITE POLYESTER 175FI79°C 341 4.2K PENDENT (112"NPT) TV2231 WHITE (5AL9010) 200F/93°C 370 5.6K UPRIGHT (10NPT) TV3131 9 CHROME PLATED 286 1 286°F1141-C LEAD COATED 371 5.6K PENDENT (1!2"NPT) TY3231 7 390 8.0K UPRIGHT (314"NPT) TY4131 391 8.0K PENDENT (314"NPT) TY4231 * Eastern Hemisphere sales only. 360 8.0K UPRIGHT (1!2*NPT) TY4831 361 8.0K PENDENT (1/2"NPT) TY4931 TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS L in In no event shall TFBP be liable, in unite contract, tort, strict liability or under any other legal theory, for incidental, Warranty indirect, special or consequential dam- ages, including but not limited to labor Products manufactured by Tyco Fire & charges, regardless of whether TFBP Building Products (TFBP) are war- was informed about the possibility of ranted solely to the original Buyer for such damages, and in no event shall ten (10) years against defects in mate- TFBP's liability exceed an amount nal and workmanship when paid for equal to the sales price. and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired In accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or Inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made In contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PIN (specify from Table 0). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, PIN 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, PIN 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 IMPERIAL MAX REC. LOAD LBS. METRIC PIPE ROD PIPE ROD 1/2 3/8 400 10 314 318 400 20 10 3/8 400 25 10 11/4 3/8 400 32 10 11/2 3 400 40 10 2 3/8 400 50 10 21/2 3/8 600 65 10 3 600 80 10 31/2 318 600 to 1000 100 10 5 1/2 1250 is 12 1/2 1250 150 12 8 1/2 1250 200 12 Order Part #300m Note: 1/2 Ring Hanger not <FM> approved em 300 RING HANGER I thru 4 Inch pipe 112 and 314 Inch pipe 5 thru 8 Inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification. FINISH - Mu. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H-1 7 1 (Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1 thru 4 inch: * Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru 3 inch: UL listed to accept AFCON#3 10 Surge Restrainer. Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index 02/01 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. FOR SERVICE LOAD LBS. TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in 1 inch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. 2/00 ( D Use #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk ma Box Qty Weight Case (per 100) Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 GST 100 1 1/4 100 5.00 1000 22 GST 200 2 1/4 100 6.50 1000 23 GST 300 3 1/4 100 7.50 1000 24 GST 600 6 1/4 50 9.00 500 WOOD - Sammys I #14 (Item #100-black) Sammys 114', 3/8" rod q Wood Joist TJI Joist! Truss Consult truss manufacturer for recommended installation point *pre..drlilng may be required for items #27 and #06. Tools available on page 9. ( Double Sheetrock Ceiling Minimum 2" imbedment into base material for NFPA 13 compliance Forvertical use. Install in center of iowerface. UL Listings and CAD Drawings are available at www.SammySuperScrew.com Note: Screws must he installed with appropriate nut driverto comply with Use #14 Nut Driver (Item #100) Approvals Item# Model Shk Lgth Shk ma FMTest Load, lb. UL Test Loadlix ULIFM Actual Pipe Size Pullout Box Qty 10 GST.75 3/4 1/4 564#-6Ply 100 NFPA 11 GST 10 1 1/4 210# - 7/16 OSS 100 670# - 3/4" Ply ULfM44IPA 12 GST 20 2 1/4 940# 850# 3/4-21/2 1760#-Fir 100 UL(JFPA * 27 GST 25-380 21/2 3/8 1500# 4 2113/! - Fir 50 ULFMi.1FPA 13 GST 30 3 1/4 1475# 1500# 3/4-4 2060#-Fir 100 NFPA 403 GST 40 4 1/4 2180#-Fir 50 NFPA 14 1 GST 60 6 1/4 2230#-Fir 50 i #I4SW (Item#1014e Sldewtnders& Sammys 1/2" rod Use #14SW Nut Driver (Item #101) Item # Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight Case Qty 8 GST2 2 1/4 1760#-Fir 50 7.00 500 * 06 GST2.5-380 21/2 3/8 2113#-Fir 50 10.00 500 15 GST3 1 3 1 1/4 2275/! - Fir 1 50 1 10.50 1 500 - 16 GST4 4 1/4 2180#-Fir 50 10.60 500 17 GST6 6 1/4 1 2230#-Fir 50 1 10.95 1 500 Not less than 2" nominal width (1112") Page 4