Loading...
HomeMy WebLinkAbout6010 GATEWAY RD; ; FPC2018-0246PERMIT REPORT (bty of Carlsbad Print Date: 04/08/2021 Job Address: 6010 GATEWAY RD, CARLSBAD, CA Permit Type: FIRE-Construction Commercial Work Class: Parcel #: Track#: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: UPTOWN BRESSI RANCH Description: UPTOWN BRESSI - UNDERGROUND BLDG #18 Permit No: FPC2018-0246 Status: Closed - Finaled Underground Fire Applied: 07/30/2018 Issued: DEV12023 Finaled Close Out: 04/08/2021 Inspector: Final Inspection: Applicant: FPContractor: CAL-WEST FIRE PROTECTION SPECIALIST CAL-WEST FIRE PROTECTION GONZALO PENA 8361 COMMONWEALTH AVE 8361 COMMONWEALTH AVE BUENA PARK, CA 90621-2525 BUENA PARK, CA 906212525 (714) 912-4552 (714) 912-4552 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $625.00 Total Fees: $625.00 Total Payments To Date: $625.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 16. ek ... Fire Protection by Computer Design Cal-West Fire Protection 1113 N Gates St. Santa Ana, Ca. 92703 866-374-9378 *Job Name : Uptown Bressi "Bldg. #18" Building Location : El Fuerte St. & Gateway Rd. System Contract : 18-099 Data File : Bldg. -18.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C Cal-West Fire Protection Page 1 Uptown Bressi "Bldg. #18" Date 7.19.18 City Water Suppjy: Demand: Cl -Static Pressure : 100 Dl - Elevation : 1.516 C2 - Residual Pressure: 20 D2 - System Flow : 500 C2 - Residual Flow : 2500 D2 - System Pressure : 15.350 Hose ( Demand) D3 - System Demand : 500 Safety Margin : 80.577 150 140 130 p120 p110 Cl E10° 90 80 70 R 60 E 50 40 30 D2 C2 —___________ 10 I ... ... ....... 300"600 900 1200 1500 1800 2100 2400 2700 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Cal-West Fire Protection Page 2 Uptown Bressi "Bldg. #18" Date 7.19.18 Fitting Legend Abbrev. Name % % 1 1% 11/2 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 C NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zif Febco 876V Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Cal-West Fire Protection Page 3 Uptown Bressi "Bldg. #18" Date 7.19.18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. BOR 0.5 0.0 na 500.0 UGI -3.0 2.89 na UG2 -3.0 4.62 na UG3 -3.0 13.21 na SRC -3.0 15.35 na The maximum velocity is 12.15 and it occurs in the pipe between nodes UG2 and UG3 Computer Programs by Hydratec Inc. Revision: 50.52.1 Mal Calculations - Hazen-Williams Cal-West Fire Protection Page 4 Uptown Bressi "Bldg. #18" Date 7.19.18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 500.00 4.26 E 13.167 12.000 0.0 Qa = 500.00 to 120.0 0.0 13.167 1.516 UGI 500.0 0.0545 0.0 25.167 1.372 Vel = 11.25 UGI 0.0 4.23 2E 38.446 8.000 2.888 to 150.0 0.0 38.446 0.0 UG2 500.0 0.0373 0.0 46.446 1.734 Vel = 11.42 UG2 0.0 4.1 3E 49.537 10.000 4.622 to 150.0 Zif 0.0 49.537 6.000 * * Fixed Loss = 6 UG3 500.0 0.0435 0.0 59.537 2.588 Vel = 12.15 UG3 0.0 4.23 G 3.845 15.000 13.210 to 150.0 T 38.446 42.290 0.0 SRC 500.0 0.0374 0.0 57.290 2.140 Vel = 11.42 0.0 500.00 15.350 K Factor= 127.62 Computer Programs by Hydratec Inc. Revision: 50.52.1 I- H A H Ci .:..WAFER CHECK VALVES • .1 1M Co.] UL /FM Rev. 2-03 i FIRE PROTECTION PRODUCTS A-2102 Wafer Check Valve 40, 6, 8" 175 psi (1207 kPa) Working Pressure 350 psi (2413 kPa) Test Pressure Listed by Underwriters Laboratories, Inc. and Approved by Factory Mutual Research Corporation. PARTS LIST Catalog Parts Description Number Material Material Standard CW-1 Seat Ring Cast Bronze ASTM B584 CW-2 Body Cast Iron AS1'MA126 CW-3 0-Ring (2 req'd) Buna-N ASTM D2000 CW-4 Clapper Cast Bronze ASTM B584 CW-5 Bushing (2 req'd) Brass ASTM B16 CW-6 Spring Stainless Steel Type 302 CW-7 Hinge Pin Stainless Ste-el-[Type 303 CW-8 Seal, Seat EP Rubber I ASTM D2000 F!! DIMENSIONAL INFORMATION FOR WAFER CHECK VALVES DIMENSIONS _____ In. A (mm) In. B (mm) C In. (mm) In. D (mm) In. E (mm) E Size 4 3.75 (95) 1.34 (34) 6.88 (175) 3.00 (76) 4.03 (102) 6 3.75 (95) 1.53 (39) 8.75 (222) 4.56 (116) 6.06 (154) 8 4.25 (108) 1 1.92 (49) 11.00 (279) 1 6.00 (152) 1 7.98 (203) WAFER CHECK VALVE ORDERING INFORMATION Specify: Quantity, Size and Catalog Number. WAFER CHECK VALVE PARTS ORDERING INFORMATION Specify: Quantity, Catalog Number, Part Name, Size of Valve, Catalog Number of Valve and Year Date of Valve. WAFER CHECK VALVE WEIGHTS 4 6 1 8 EKg Lb15.75 22.50--[--36.50 7.14 10.21 1 16.56 Page C-1-6 No. 135 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Sprouts Farmers Market SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 6217 El Fuerte St CITY: Carlsbad PHONE: ( 714) 914-4552 (Cal-West Fire) FAX NUMBER:( 714 ) 912-4641 Largest Building (ft.2): 26.000 Sprinkled? Yes Construction Type: UNK SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): El Fuerte St north of Gateway Rd TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 129 PSI Hydrant Number (if applicable):H20910 Elevation of test: 402 Feet Main Size: 24 INCH Pressure Zone: 700 Feet Date/Time ofTest: Pitot Tube Reading PSI Corr espondIng Flow GPM Total Flow: 8,000 GPM Residual Pressure 110 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name: Jennifer R.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Title/Or g(j'j41ectManager Date: 01/11/2018 C LEIGHTON CR 8 LRIINGTONWf jWANCOCK ALAMEDA CR OWN GARDEN RD 3 8- 12' 12 14, / 'I N Legend ZONE / I I + Pipe 30. ftQ4OR 1 -700 A AVROl2i z/ 30. II - - F] -1 \_ '! liIx I Fire Flow Test Location H20910 - $ I ~ Sprouts Farmers Market - Fire Flow Analysis MJ Accessories ANSI/AWWA C111/A21.11 O.D. B.C. -I C JINurnLI IP] I1 BOLT LT In BC LE (LBs) 2 612 062 118 340 261 47, 007S 2 1 3 O6 -- 1.37 484 406 619 4 - s 70S 4 9.12 0.75 I.-SO 5.92 4.90 7.S0 00.88 4 6 6 1112 088 163 802 - 00 90 6 10 8 1337 100 - 179 101' 915 11.75 00.88 6 ic TT 7TT -iT T - 20 oT 12 1788 100 1.7-S 1432 13.30 1625 00.88 8 24 14 . 202 1 - .'00 - 1640 1944 18'S 10 - 45 8 16 22.50 1.31 206 18.50 1'_54 21.00 0088 12 55 18. '2475. 138 2.13 * '20.60 23.2 0088 . 12 55 1964 20 2700 144 2.19 22.70 2174 2530 0088 14 -- - 66 24 3150. 1 56 ------ -. 31 '26.90 --- -- - ----'------..-- 594 _. i.- - 3000 - .--- 0088 16 90 30 3912 200 275 3329 3217 3688 01.13 20 220 4690 200 2Th 99 45Th 2 47 24 42 53.12 2.00 2.75 4579 44.67 50.62 0138 28 288 - oi ___ 4 7 3f 11It OVERSIZE II ABOLT BC ry OLEW Wks.) 075 150 592 510 750 0088 - 4 3 6 1112 088 To 802 950 - 0088 6 720 8 1337 100 175 1 'S * 10.17 '12.22 t5.62 940 11 0 - 1179 1400 -078"-,- 0088 6 6 10 . 100 12 1788 - 1.00 1_7, - 14.32 1360 - 16.25 0088 8 9 16 1.31 -'s .91830 17.94. 21.00 00.88 12 14 UCAT.I4DI REGISTERED TRADEMARK OF STAR PIPE PRODUCTS 9rAW PIPE PRODUCTS HOUSTON CORPORATE _TOLL FREE I-BX999-3N PAX lBI.533.9E5 wwMApodcom Page 15 ~0,~ J MagI Building essentials e for a better tomorrow I toll 1i!III1 SUBMITTAL AND DATA SHEET PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. -[ (IN) MIN. T. -j (IN) MIN. E (IN) APPROX. D9 (IN) APP ROX. WEIGHT (LBS/FT) PRESSURE CLASS 165 psi (DR 25) 4 4.80 4.39 0.192 5.25 5.57 1.9 6 6.90 6.31 0.276 6.40 8.00 3.9 8 9.05 8.28 0.362 7.05 10.50 6.7 10 11.10 10.16 0.444 8.20 12.88 10.1 12 13.20 12.08 0.528 1 8.80 15.31 14.4 PRESSURE CLASS 235 psi (DR 18)* 4 4.80 4.23 0.267 5.25 5.87 2.6 6 6.90 6.09 0.383 6.40 8.43 5.3 8 9.05 7.98 0.503 7.05 11.06 9.2 10 11.10 9.79 0.617 8.20 13.57 13.9 12 13.20 11.65 0.733 8.80 16.13 19.7 PRESSURE CLASS 305 psi (DR 14)* 4 4.80 4.07 0.343 5.25 6.17 3.2 6 6.90 5.86 0.493 6.40 8.87 6.7 8 9.05 7.68 0.646 7.05 11.63 11.6 10 11.10 9.42 0.793 8.20 14.27 17.6 12 13.20 11.20 0.943 8.80 16.97 25.1 Consult JM Eagle for CSA and other listing availability prior to shipment. Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. * Contact your JM eaglelM sales representative for location availability. ID. : Inside Demeter O.D. : Outside Diameter T. : Wall Thickness D9 : Bell Outside Diameter E: Distance between Assembly Mark to the end of spigot. Assembly Mark Product Standard: ANSI/AWWA C900 Pipe Compound: ASTM D1784 Cells Class 12454 Gasket: ASTM F477 Integral Bell Joint: ASTM D3139 Certifications: ANSI/NSF Standard 61 UL Standard 1285 Pipe Length: 20 feet laying length Installation: AWWA C605 JM Eagle" Installation Guide JM Eagle 1M also manufactures this pipe in green for sewer force main applications and purple, specifically for reclaimed water systems. This pipe is made to the same requirements as our standard products. The only difference is that the pigment used is green or purple. These products will not be marked with UL or NSF listing marks. Additionally, the green pipe will be marked "Forced Sewer" and the purple pipe will be marked: "Reclaimed Water.. Do Not Drink" Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative - MasterSeries® LF876V Double Check Detector Backf low Prevention Assemblies (Type II) Size: 21/2" - 8" (65mm - 200mm) The FEBCO MasterSenes LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This Backflow Assembly is primarily used on potable drinking water systems and fire sprinkler systems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal "N-Pattern" Installations Vertical-Up "Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Reid Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1St & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4" Backfiow Assembly No Special Tools Required for Servicing Field Replaceable Seats & Discs Detect Potential Underground Water Leaks Detect Unauthorized Water Usage Model LF076V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper We check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL/ FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by AWWA Standard C510. The auxiliary bypass line contains a %x~" Water Meter that complies with ANSVAIMNA Standard C700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of AWWA Standard C510 flow and pressure loss performance parameters. i'fl1ItDI The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. i!(1111H Inquire with governing authorities for local installation requirements "The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. FEBCO prnduotspeclficebons in US customary units and metric are appicunnate and are pded for reference only. For precise meaarirement please cwW FEBCO Technical SeMce FEBCO reserves the right to change or modify pmduct design, construction, spectlicidions,materials with- out prior notice and without incurring any ohlitiou to make such changes and mothftcationson FEBCO products prevor subsequently anId. A WAFTS Brand Options - Suffix OSY: ULJFM Approved OS&Y Gate Valves [ANSI/AWWA 0515 Compliant] CFM: Totalizing Cubic feet/mm %"x 3/4" Water Meter [ANSI! AWWA 0700 Compliant] GPM: Totalizing Gallons/mm %"x 3/4" Water Meter [ANSI/ AWWA C700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4" LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4" LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer: FDA Approved [ASME B16.1 Class 125 & AWWA Class D Range] Series 611 Valve Setter MJ x MJ - Mechanical Joint x Mechanical Joint [AWWA C1 1/A21.11] MJ x FL - Mechanical Joint x Range [AWWA C1 1/A21.11; ASME B1 6.1 Class 125/AWWA Class D Range] FL x FL - Flange x Range [ASME 616.1 Class 125 & AWWA Class D Range] Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [F000HR-USC] ASSE 1048 Usted **UL Classified [US & Canada] **FM Approved IAPMO/cUPC AWWA Standard 0510 Compliant End Connections: Compliant to ASME 616.1 Class 125 & AWWA Class D Range —Assembly configured with ULJFM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations. Assembly Flow Orientation: Horizontal 'J-Pattern 21h" —8") - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC Vertical Up (Z-Pattem 21h" —8") - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC IN ® <e C 408C r:; *1 Approved C®US 1048 B645 Materials Below is a general materials list of the Modal LF876V. All assemblies size 21h" through 8" is similar in materials and construction. Please contact your local FEB00 Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AWWA 0550-90 Shutoff \Mves: OSY resilient wedge gate valve AWWA 0515 (UL/FM) Check Seats: Stainless Steel Disc Holder: Stainless Steel Elastomer Disc: Silicone Spring: Stainless Steel Clamp: AMA 0606 To 81 Pressure - Temperature Max. Working Pressure: 175p5i (12.1 bar) Min. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350p5i (24.1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous Dimensions - Weights Size: 21/211 - 811 Below are the nominal dimensions and physical weights for the Model LF876V size 21h' through 8". Allowances must be made for normal manufacturing tolerances. Please visit our website to download a copy of this product's installation instructions, or contact your local FEBCO Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) 'I Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V SIZE (ON) - - - DIMBilSIONS - - - - WEICHP in. mm A ii. mm B in. mm C amm Im mm DE in. mm in. mm FG H I in. mm in mm in. mm I in. mm in mm a mm lbs. . 21h 65 291A 740 121h 318 61/4 159 251/4 642 17½ 445 13% 346 271/4 692 51h 140 11½ 283 3½ 89 16% 416 11½ 292 216 98 3 80 291h 740 121h 318 61/4 159 25% 654 17% 451 141A 359 281/4 718 51h 140 11½ 283 A 95 221/4 565 11½ 292 242 110 4 100 31½ 791 14 356 7 178 27% 705 18% 476 151h 394 31 787 6 152 1114 283 41h 114 231/4 591 13 330 347 157 6 150 35% 908 16 406 8 203 32Y, 831 221h 562 18% 473 371/4 945 71/g 184 121h 316 51h 140 1301A 765 113 330 529 240 8 200 40% 10351181h 470 91/4 235 1 36Y, 933 2514 638 203/4 527 1 411h 10541 81h .2161 14 356 11 6Y, 172 37% 959 1141h 368 1 827 375 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) Indicates weight of complete Backflow Assemblies with specified Gate Valves 751 2211 3785 5300 on 7.5 11.4 17.0 fps Service Flow Rated Flow IlL Rated Flow Stancteiti Orientation N-Pattern Flow Curve Pipe Support I (furnished by customer) for valve weight only. 4ç•J •Z-Pattem Flow curve Z 3" LF876V pal Service Flow Rated Flow IlL Rated Flaw 22 25 I - 18 - 8• IS - 14 - g 12 e 10 i 0 50 100 150 200 250 300 350 400 450 500 gpm 319 157 1136 1514 10m 7.5 14.5 22.0 fps 4" LF876V psi Service Flow Rated Flow IlL Rated Flow 18 - 16 - 14 - 12 11 0 100 200 300 400 500 600 700 800gpn, 379 1136 1893 2650 on 7.5 12.8 19.1 fps 8" LF876V psi 18 16 14 ii 12 Service Row Rated Row IlL Rated Flow 0 400 500 1200 1600 2000 2400 gpm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps Performance Row capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. AWNA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than lofps. UL flow rate is determined by tcalIy rated Velocity of 15 feet/sec. Capacity N-Pattern 2W' LF876V PSI Service Flow Rated Flow IlL Rated Now 20 51 - 18 - 16 - 14 1 - 12 ic TTT 0 25 50 75 100 125 100 175 200 255 250 275 300 305 320gpm 284 568 852 1136 1pm 7.5 14.7 22.0 fps A WAITS Brand USA: Tel: (800) 767-1234 • Fax: (800) 788-4491 • FEBcOonline.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • FEBCOonline.ca Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBCOonline.com ES-F-LF876V 1515 0 2017 FEBCO ES-A-InBuiIdingRiser Series IBR fflk A M E S In-Building Risers Sizes: 4" - 10° (100 - 250mm) MTrOT"; CAP 001 ow Series IBR In-Building Risers are used to connect the main fire supply to the building overhead fire system. The fitting passes under the foundation without joints and extends up through the floor. Provided with installation tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connec- tion to the underground supply (AWWA C900 PVC and Ductile Iron Pipe) and industry standard grooved-end connection (AWWA C606) on the building side for easy connection to the overhead fire sprinkler system. Ames In-Building Risers are precision engineered and manufactured to provide exceptional reliability and reduce installation time & labor costs associated with field assembly. In accordance with NFPA 24-2007, the UL/FM approved In-Building Risers replace numerous fittings, elbows & spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation. The use of stainless steel signifi- cantly increases the reliability and life of the riser. Contractor Approval Contractor's P.O. No. Representative - Features Cost savings Corrosion resistant stainless steel construction, type 304 Ease of installation and light weight allows one person to position and handle the riser Minimal site preparation; joint restraint one-piece construction reduces time and labor; no missing parts, no leaks; easily identifiable for approvals Includes Test Cap and Coupler UL/FM approved Sizes: available in 4" - 10" (100-250mm) with various lengths to meet all local requirements Designed to meet NFPA 24-2007 Section 10.6.5 AWWA C900 Inlet/DIP *The wetted surface of this product contacted by consumable water contains less than one quarter AWWA C606 Outlet of one percent (0.25%) of lead by weight. Job Name Job Location Engineer - Approval - Ames product specifications in U.S. customary units and metric are apprommate and are provided for reference only. For precise measurements, please contact Mien Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Specifications In-Building Riser shall be installed as indicated on the plans. Riser shall be composed of a single extended 90 degree fitting of fabricated 304 stainless steel tub- ing, maximum working pressure 200psi (14 bar). The fitting shall have a grooved-end connection on the outlet (building) side and a ClPS coupler on the inlet (underground) side. The grooved end shall include a coupler and cap to facilitate testing of the underground piping. The In-Building Riser shall be an Ames Fire & Waterworks Series IBR. Approvals Fittings FM class 1920 UL HKQA (4"-110") Us L 4Q8& Dimensions - Weights A Grooved End f (Flange Optional) J- UPS Coupling Tie-Rod Bracket 1 c in. mm A(OD) in. mm B It an C ft an lbs. kg 4 100 41h 114 6 183 6 183 71 32 6 150 6% 168 6 183 6 183 98 44 8 200 8% 219 6 183 6 183 129 59 10 250 1 10/4 273 1 6 183 1 6 183 1 202 92 Consult factory for custom leg dimensions. Standards NFPA - Designed to allow the contractor to conform to NFPA 24-2007 Section 10.6.5: Where a riser is close to building foundations, under- ground fittings of proper design and type shall be used to avoid pipe joints being located under the foundations. NFPA 24-2007, 10.1.1, 10.6.7 End Connections Horizontal End: Mates with Ductile Iron Pipe and AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe Equivalent OD's) Utilizes Gasket conforming to UL 157 with "Lock in" gasket configuration 1Y11Pli1 Mt1iI[l5Il1I1I in. mm in. mm 4 100 4.8 122 6 150 6.9 175 8 200 9.1 230 10 250 1 11.1 282 Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe Meets AWWA C-207 class D for flanges Ratings Meets AWWA C-900 pressure class 200, DR 14 Pipe Testing Welds are 100% leak tested at the factory SIZE DESIGN PROOF ft mm psi bar 4 100 1000 70 6 150 1000 70 8 200 800 56 10 250 500 55 IMPORTANT: Inquire with governing authorities for local installation requirements. A _ A M E S %!J II9OO1 -2000 FIRE&WATERWORKB www.amesfirewater.com ICERTIFIED A Watts Water Technologies Company USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 • T. 916-928-0123 • F: 916-928-9333 Control Valves- 18550 Hansen Road • Houston, D( 77075 • 1: 713-943-0688 • F: 713-944-9445 Canada: 5435 North Service Rd. • Burlington, ONT. LX 5H7. T: 905-332-4090 • F. 905-332-7068 ES-A-InBuildingRiser 0935 0 2009 Ames Fire & Waterworks PACIFIC STATES co CAST IRON PIPE COMPANY DIVISION OF MWNE, INC. P.O. BOX 1219, PROVO, UTAH 80603 TELEPHONE (AREA CODE 801) 3736910 STANDARDS In each of the following, standards are developed by committees consisting of consumer, general interest and manufacturing members: American National Standards Institute (ANSI) American Water Works Association (AWWA) American Society for Testing and Materials (ASTM) Underwriters Laboratories (UL) MH16433(N) National Fire Protection Association (NFPA) National Sanitation Foundation (NSF) 61-1989 Factory Mutual (FM) J12V0A8.AH For ready reference, standards for ductile iron pipe are listed below: Standard Desi2nation ANSI/AWWA C150/A21.50 ANSI/AWWA C151/A21.51 ANSI/AWWA C11O/A21.1O ANSI/AWWA C1531A2 1.53 ANSI/AWWA C111/A21.11 ANSI/AWWA C115/A21.15 ANSI/AWWA C104/A21.4 ANSI/AWWA C105/A21.5 & ASTM A674 ANSI/AWWA C600 ASTM A746 NFPA Outside Protection 24 Subject Covered Design Water Pipe Fittings - Cast Iron Fittings - Ductile Iron Rubber - Gasket Joints Flanged Pipe Cement - Mortar Linings Polyethylene Encasement for Ductile Iron Pipe Installation Gravity Sewers Fire Protection Piping Pacific States ductile iron pipe meets and exceeds the requirements of all of the above national standards relating to pipe manufacture and performance. PACIFIC STATES CAST IRON PIPE COMPANY DIVISION OF McWANE, INC. P.O. BOX 1219, PROVO, UTAH 84603 TELEPHONE (AREA CODE 801) 373-8910 FAX: (801) 377-0338 EMAIL: sales@pscipco.com WEBSITE: www.pscipco.com Thickness, Dimensions and Weights of Mechanical Joint Ductile Iron Pipe by Size for Each Thickness. Nominal Wt. of Barrel Mechanical Joint Wt. of Wt. Per Avg. Wt. Thickness Thickness OD* Per Ft. t Bell Lgth.j Per Ft.$ Size Class In. In. Lb. Lb. Lb. Lb. 3 53 .31 3.96 10.90 II 230 11.4 4 53 .32 4.80 13.80 16 290 14.6 6 53 .34 6.90 21.40 18 405 22.4 8 53 .36 9.05 30.10 24 565 31.4 10 53 .38 11.10 39.20 31 735 40.9 12 1 53 1 .40 1 13.20 1 49.20 1 37 1 925 51.3 tinduding bell; calculated weight of pipe rounded off to the nearest 51b *Tolerances of OD of spigot end; 3-12 in. ±0.06 in. *Including bell; average weight per foot, based on calculated weight of pipe before rounding. , *N-- Md -155 I I i J- - PPOUDLY C :MADE INELMIPA, NEW.YORK ,USA I- (Revised O3272O J Visit our website at v KENNEE A C VISION OF MCWANE NC I A During the decade of the 1980's, the waterworks industry was introduced to the Resilient Seated Gate Valve, a design principle that is dominant in preference for use in distribution systems. Kennedy Company was at the forefront in this industry-wide movement by introducing the Ken Seal Series, our AWWA C509 Resilient Seated Gate Valve. In 2002, with the end user in mind, Kennedy redesigned the Ken Seal Series introducing the model KS-FW. The goal of the redesign was to eliminate the customer need for any anti- rotational bolts. Kennedy did this by designing a machined elliptical bolthole in place of an as-cast opening. This elliptical design allows valve Installers to slide a standard sized bolt into the slot, therefore eliminating the need to have two different types of bolts on the installation. RECOMMENDED SPECIFICATIONS FOR C509 CAST IRON RESILIENT WEDGE GATE VALVES KENNEDY VALVE COMPANY Valves shall conform to the latest revision of AWWA Standard C-509 covering resilient seated gate valves for all water supply service. The valves shall have a cast iron body, bonnet, and 0-ring plate. The wedge shall be totally encapsulated with rubber. The sealing rubber shall be permanently bonded to the wedge per ASTM D429. Valves shall be supplied with 0-ring seals at all pressure retaining joints. No flat gaskets shall be allowed. Blind bolts shall not be allowed. The valves shall be either non-rising stem or rising stem, opening by turning left or right, and provided with 2" square operating nut or a handwheel with the word "Open" and an arrow to indicate the direction to open. Stems for NRS assemblies shall be cast bronze with integral collars in full compliance with AWWA. OS&Y (rising stems) shall be bronze. All stems shall operate with bronze stem nuts independent of wedge and of stem (in NRS valves). Stainless stems are available but not standard. NRS stems shall have two 0-rings located above thrust collar and one 0-ring below. Stem 0-rings shall be replaceable with valve fully opened and subjected to full pressure. The NRS stems on 2"-12" shall also have two low torque thrust bearings located above and below the stem collar to reduce friction during operation. Waterway shall be smooth, unobstructed and free of all pockets, cavities and depressions in the seat area. Tapping valves 4" and larger shall accept a lull size tapping cutter. The body, bonnet, and 0-ring plate shall be fusion-bond epoxy coated, both interior and exterior on body and bonnet. Epoxy coating shall be NSF 61 certified and applied in accor- dance with AWWA C550. Each valve shall have manufacturers name, pressure rating, and year in which it was manu- factured cast in the body. Prior to shipment from the factory, each valve shall be tested by hydrostatic pressure equal to the requirements of AWWA C-509 (and UL/FM where applicable). Valves shall have all component parts cast and assembled in the USA and shall be manufactured by the Kennedy Valve Company. (Revised 03.27.2011) Features and Benefits DELRIN THRUST BEARINGS ABOVE AND BELOW THE THRUST COLLAR REDUCE FRICTION AND MINIMIZE OPERATING TORQUES LONG, TROUBLE FREE LIFE WITH HIGH STRENGTH, NON-CORRO- SIVE BRONZE STEM AND STEM NUT. ALL NRS STYLE VALVES ARE STAIN- LESS THE OPERATING MECHANISM IS TRIPLE 0-RING SEALED TO COMPLETELY SEAL AGAINST LEAKAGE PAST THE STEM. TWO 0-RINGS ARE PROVIDED ABOVE THE THRUST COLLAR AND ONE BELOW. UPPER 0-RINGS CAN BE REPLACED UNDER PRESSURE WITHOUT REMOVING THE STEM WHEN THE VALVE IS FULLY OPENED. O-RING SEALS AT STUFFING BOX AND BONNET TO BODY FLANGES TO ENSURE THE BEST POSSIBLE SEAL. NO FLAT GASKETS. 100% EPDM COATED WEDGE WITH TWIN SEAL DESIGN ENSURES BUBBLE- TIGHT SEAL UP TO 250 PSI EVERY TIME. ELLIPTICAL BOLT HOLE DESIGN ELIMINATES THE NEED FOR ANTI-ROTATION BOLTS KENNEDY CORROSION RESISTANT FUSION- BONDED EPDXY COATING, CONFORMING TO AWWA C-550 AND NSF61 CERTIFIED, PROTECTS BOTH INSIDE AND OUTSIDE OF VALVE. SMOOTH, UNOBSTRUCTED PADS ON THE BOTTOM OF FULL SIZE WATERWAY IS ALL VALVES KEEP VALVE FREE OF POCKETS, CAVI- IN UPRIGHT POSITION TIES, AND DEPRESSIONS FOR EASIER STORAGE ALLOWING FOR MINIMAL AND PROTECTION FROM FLOW LOSS AND LOWER THE ELEMENTS. PUMPING COSTS. ALL TAPPING VALVES ACCEPT FULL SIZE TAPPING CUTTER. ALL VALVES ARE RATED AT 250 PSI FOR AWWA SERVICE AND 200 PSI FOR ULFM SERVICE. ALL VALVES ARE HYDROSTATICALLY TESTED TO 500 PSI. 10 YEAR LIMITED WARRANTY (Revised 03-27-2011) ..j 9A 8571 8561 8057 8572 MECHANICAL JOINT ENDS FLANGED ENDS THREADED ENDS FLANGED X MJ 2 2" F 12" ski NA 8597 8576 8901 8701 PUSH-ON FOR PVC MECHANICAL TYTON ENDS FLANGED ENDS 2'.8. CUTTING-IN JOINT PUSH-ON FOR (D.L & 0900) POST INDICATOR VALVE (PIV) 4 • 12" 5". 12" F TT- _14~ fOr 8902 8950 8071 8068 FLANGED & TYTON JOINT TAPPING X MJ MECHANICAL JOINT FLANGED ENDS PUSH-ON FOR (DL & 0900) TAPPING VALVE POST INDICATOR VALVE (PIV) OS&Y CONSTRUCTION 4" • 12" 4" • 12" 3" • 12" 2 112" • 12" A B C D E G H P Q R S U V No. TU to Full or: 2" 7 31/4 - 51/4 10 7/8 - - 3 - 7114 - 4 3/4 2 lIT 7 1/2 - - 7 11 3/8 - - 31/4 163/8 13 7/8 71/4 - - 51/2 3" 8 31/2 - 71/8 123/8 , - 5 3/4, 3 1/2 187/8 15 5/8 10 - 1 - 10 4 9 41/2 63/4 - 143/4 41/2 63/4 41/2 223/4 18 1/4 10 63/4 93/4 131/2 6" 101/2 5 77/8 - 19 51/4 73/4 5 301/8 233/4 12 75/8 11 3/16 19 1/2 8. 111/2 51/2 81/2 - 221/2 55/8 8 1/2 51/2 373/4 29 1/4 14 81/2 113/4 251/2 10" 13 7 10 - 261/2 7 10 - 453/4 353/8, 18 1 10 131/2 311/2 iT 14 63/4T 111/4 - 30 i 8 1/2 107/8 1 - 531/8 140 5/8 1 18 1 11 14 3/4 137 3/4 KENNEDY VALVE A DIVISION OF MCWANE, INC. www.kennedyvalve.com 2007 1021 E. Water Street Elmira, New York 14901 P.O. Box 981 Phone (607) 734-2211 Fax 1-607-734-3288 (Revised 03-27-2011) MJ Accessories ANSI/AWWA C111/A21.11 s - - - - - - - T - - - - - - L L. .W I I 2 for sizes 3.24 in. F 20 for sizes 30.60 (!II]kGASKET NOW 1IPE. J".' ' F G - 2 7 60 048 062 031 2.48 012 016 10 396 - 048 062 0.31,386 012 015 105 4 480 062 0.76 031 468 016 022 1.22 _0.62_ 031 673 016 ... - - 0.2' 8 905 - 062 0.75 031 88 0.16 022 1.22 10 1110 062 0.75 061 108' 016 022 1.22 12 1320 062 0.75 031 1295 016 072 1.22 14 1530 062 0,715 03F 1499 -- 0.16 - O' 22 16 1740 062 0.75 031 1707 016 022 1.22 18 1950 062 07- 031 1913- 016' 022 1.22 20 - 2160 062 0.75 031 2120 016 022 1.22 24 2580 062 0.7s 031 2534. 016 022 1.22_a 30 3200 073 - 1.00 038 31.47 0.16 037 1__64 .36 3630 073 1.00 - 038 37.67 0.16 0.37 154 -1 42 44.50 073 1.00 0.38 43.78 0.16 037 1.54 48' 1 60.80 0.73 LOt) 038 49.98 0.16 0.Y' 14 " OL zzb EE -J__1 A 1_ -]k F ')/28• -. look, A TRANSITION JIIMECHANICAL-JOINT I'VI OD 2 2.375 0.56 0.66 0.31 2.32 0.12 0.21 1.10 3 i 990 072 064 0.34 3.43 0.12 0.38 110 4 4.500 0.76 0,73 0.33 4.43 0.20 0.37 1.26 6 6 6' 0 75 076 040 6 S 3 -0.20 036 1.25 8 8.625 0.82 0.73 0.34 8.50 0.20 0.43 1.27 10 10.750 079 075 031 1059 020 039 126 12 12.750 0.84 0.7S 0.33 12.56 0.20 0.44 1.28 UCAT.i4flI O V 'REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAIVPIPE PRODUCTS HOUSTON CORPORATE TOLL FREE I.ses-999.39PAXZEI.SSE.9000 Page 17 MJ Accessories ANSI/AWWA C111/A21.11 1-Bolts, Double Ended Rods & Nuts HSLA STEEL SPECIFICATIONS: Bolts & Nuts are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1. Material is High Strength Low Alloy Steel per ANSI/AWWA C1 1/A21.1 1. Threads per ASME 81.1 unified standard coarse (Class 2A & 2B) MECHANICAL PROPERTIES Yield Strength 45000 PSI (mm) Elongation in 2in. 20% (mm) BLUE BOLT/NUT/ROD CHEMICAL PROPERTIES Carbon 0.20% Max Manganese 1.25% Max Sulfur 0.05% Max Nickel 0.25% Mm Copper 0,20% Mm Combined 1.25% Mm (Ni, Cu, Cr) 1-Bolts, Rods & Nuts have fluoropolymer coating material which is VOC-compliant, resin-bonded, thermally cured and dry lubricant. COATING PHYSICAL PROPERTIES Film Thickness: Number of Coats: Adhesion: Cure Test: Pencil Hardness: Volatile Organic Compounds 0.3 to 0.4 mil per coat 3 to 4 coats 1 mm cross hatch test + 5 Pulls. Good knife resistance 50+Rubs with MEK. No substrate exposure Pencil Hardness: 4-6H 2.741b5/gal Stainless Steel 1-Bolts & Nuts ALLOYS SS 304 & SS 316 PER ASTM F593 SPECIFICATIONS: T-bolt dimensions are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1. T-bolt alloys SS 304 and SS 316 per ASTM F593 Heavy Hex Nut Alloys SS 304 & SS 316 per ASTM F594. MECHANICAL PROPERTIES Tensile Strength: 85,000 PSI to 140,000 PSI Yield Strength: 45,000 PSI (mm) COATING SPECIFICATION Nuts have fluoropolymer coating material which is VOC-Compliant, resin-bonded, thermally cured and dry lubricant. COATING PHYSICAL PROPERTIES Film Thickness: 0.3 to 0.4 mil per coat • Pencil Hardness: 4-6H Number of Coats: 3 to 4 coats • Volatile Organic Compounds 2.74 lbs/gal Adhesion: 1 m cross hatch test + 5 Tape Pulls. • Continous use temperature - 356°F Cure Test: 50+ Rubs with MEK, no substrate exposure • Color: SS 304 is green, SS 316 is red UCAT.4OI REGISTERED TRADEMARK OPSFAR PIPE PRODUCTS STAR' PIPE I'R0DUCS HOUSN CORPORATEI1LI. FREE 14 999.39 F4X 201.SS& 9000 ,b,plp,pmdd,am Page 18 A. AWWA MEMBER 118-in.RadiusMaximm -0-- Accessories ANSI/AWWA C11I/A21.11 PIPE SIZE (IN) MECHANICAL JOINTl:sIU.IisU! BOLT SIZE RANGE' OF ON) TORQUE (FT-LBS) 2-3 5/8 45-60 4-24 3/4 75-90 30-36 1 100-120 42-48 11/4 120-150 'These torque ranges are requirements ofAWWA C600 T-HEAD (LOW : ALLOY STEEL) - A BOLT ' B & NUT C - r)S - F R - x 3 ½ 3/4x3½ ~x4 3/4 x4½ iso 1 ,O - 175 - 175 175 0625 300 00 ------------ ii U 10 062s 0625 0.750 0.750 - 0.750 0.750 0.750 1000 1.000 120 1250 1.250 1.062 7i62 1.250 1.250 0625 0.312 0625 0730 0750 0.750 3.50 350 400 - 4.50 500 s50 hTo 600 270 2.50 - 3.00 3.00 300 370 0.62-S 0750 oi 0.375 0.375 - 0.375 0.375'S 10 10 10 10 -.8 8 0.7S0 - 0.750 0.750 0750 1.250 - 1.250 1250 762S7- 1.625 34x5½ iTs½T 1.6 1'S 175 1722 0750 0.750 0,375 0S00 0.500 06 1,000 : .3O0. 300 300 350 i0OO 225 1.000 1.000 1¼x6¼ 'so 250 i'o = 1.250 600 650 7 7 2000 2.000 12s0 1.250 0.625 1x8 ' 1.2S0 :&-. 7 £öøü 1.25Ô 0.625 I! -- - _i( 1 AN'ri-ROTATION T-HEAD (LOW ALLOY STEEL) BOLT & NUT NOM IIrt THREADS--- -AB PER IN. 'Ax3 1.50 0625 3.00 200 063 11 0625 1.062 0623 0.312 --Ax3½ 150 0625 3.50 250 065 Ii 0.6'S . ' 106' 0.625 1312 ½x 3 I, 175 1.75 0.750 0750 350 400 230 300 063 063 10 10 - 0.750 1.250 i259 0.750 0.750 0.375 - 0.375 0.750 - 0.750 S -4' 1.75 0.750 4.0 5 07- 3.00 oO' 0.63 10 10 1.250 1250 0.750 0.375 0375 0.5 O UCAT.1401 REGISTERED TRADEMARK OF STAR PIPE PRODUCES STARPIPE PRODUCTS HOUSTON CORPORATE IOU. FREE I-seu.999-3m9 FAX2BI.33S.REEO Page 19 Nil S 4 _ .. .. BENDS (1/4) BENDS (1/8) IBENDS BENDS (lA6) BENDSmMj I S R LW A R VT' L 777 SIZE T (LBS.) ., - (LBS ) (LBS.) A R (LBS.) 2 039 3.25 222 14 180 1.96 13 1.80 402 13 1.80 8.12 13 3 048 400 1- 900 362 30 300 30 15.25 30 '6 3.00 4.00 4 052 0 6.50 :oo - 420 5 5 600 -. 8 400 481 .2S 50 S - 400 1006 50 20.31 50 6 coo 00 1506 5.00 30.50 75 8 060 900 700 122 s.so 844 110 550 1761 110 550 3550 110 - 10 1100 "0 1 S S 690 160 650 068 9.00, 190 1080 1162 160 12 0.75 12.00 1000 255 7.50 13.25 21 750 27.62 220 7.50 55.81 220 14 oW o 0 0 22 us0 30 0I 2 750 5O75 275 16 00 075 100 160 12.50 430 - 545 8.00 L 1329 340 420 800 420 2762 3019 342 430 800 55.81 345 6094 430 - 18 1410 850 950 20 080 1800 2200 1550 680 1890 1025 1688 230 5 920 11.00 3.19 535 950 1100 71.06 540 24 089 1100 1912 379 65 76.12 770 116.75 1410 _T4715 2.145 30 103 2500 2120 1690 15.00 275 1380 2095 1900 57.81 1400 1'00 1800 36 800 420 .475 %jo 835 1600 2135 42 128 3100 2720 3410 21.00 42.25 19 2100 88.00 3010 21.00 177.69 3035 48 1.42 7i 24.00 208.32 4190 3030 Io 4080 240Q 1 7T, 'A BENDS B R')185) A BENDSMJ B' 'R)LBs :wT'- A B R WTI A B 3 048 092 055 550 650 800 900 1350 400 420 600 35 20 80 300 5.00 550 630 11.00 13.00 jj 1430 362 41 7.22 10.88 30 42 70 105 125 21s 255 320 7b 7S 1930 300 4 200 2 0 650 70 7.50 11.00 11.00 7.56 30 3.00 5.00 11.00 15.25 - 30 45 13.00 30.50 70 0 lOS 1430 45.69 160 6 10 1420 16.00 1700 19.00 2000 22.00 30.00 13.00 15.06 70 060 0.68 700 9.00 1430 17 0 11.00 14.00 22.00 28.00 07iThT 10325003300 190 22.62 160 6.50 12 - 14 0.66 0.89 0 5581 15.50 50.75 260 11.50 325 7.50 15.50 12.06 T 18.12 [s.00 15.50 25.12 260 730 16 24 19.00 76.12 730 26.00 147.25 1980 1830 24.50 985 11.00 19.00 19.00 37.69 725 11.00 30 1.15 36 36.00 2310 18.00 26.00 18.00 26.00 72.88 1970 18.00 42 - L28 1:3 1-00, .39.00 i iioi ii i& UCAT.1401 REGIerEREDThADEMARKOFsTARpIPEPRODUcIs STAR MPE PRODUCTS HOUSTON C0RPOP.ATEITOI.LFIEE 1400JM.M F4(1ISSS FII Page 22 II [7i\ GUARDIAN I %1 fl7J) FIRE EQUIPMENT, INC. DETAIL AND SUBMITTAL SHEET MIAMI, FL Ph. 800.327.6584 • Fax 800.827.3869 6300 Series Jw D ept. I nletiConnections Bodi es Project/Location: Date: Qty: Contractor: Architect/Engineer: I1Appropriate Selection Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies. Provides 250 GPM flow (minimum), per 21/2" inlet. Two and three-way - inlet connections feature clappered brass bodies (straight or angle pattern), with female hose thread swivel inlets and female outlets. Cast brass construction, standard. 1Tll Back Two iand Three-Way 4"x 2'/2"x 2'/2" 81/a 1 5V2" 7."'r Angle 4" x 21/2" x 2'/2" 1 8V8" Back 8/4" 4" x 21/2" x 2'!? 2 7'/4" Angle 101/? o 3 4" x 21/2" x 21/2" 2 81/4" 10V2" 6326 Back 6" x 21/2" x 21/2" 2 71/4" 101I2" 6327 Angle 6" x 21/2" x 21/2" 2 10" 101/2" 6336 Back 6" x 2/2" x 21/" x 21/2" 3 101/2" 13/4" O 6337 Angle 6" x 21/2" x 21/2" x 21/2" 3 111/2" 141/2" Body Lettering D AUTO SPKR DSTANDPIPE Blank (unlettered) "Auto Spkr lettering only Optional Finish:[] -13 Polished Brass Threads: 0-C Rough Chrome Plated 0 NST 0 -D Polished Chrome Plated 0 Other Plugs with Chains and Break Caps - Used to keep fire dept inlet connections free of debris and protect female threads. Contact factory for current listings and approvals Plugs with Chains I Model No. I Size I Type lo 6404 Brass I Optional Finish: 0-B Polished 0-C Rough Chrome Plated 0 -D Polished Chrome Plated Break Caps Model No. I Size I Type Ui 0 6406 21/? Aluminum 0 6407 21/? Plastic Threads: Adjustable Plugs [I NST Model No. Size I.il!2iII 0 Other 0 6408 21!2" 1 Aluminum 1171 63409 21/2" 1 Plastic