Loading...
HomeMy WebLinkAbout6018 GATEWAY RD; ; FPC2018-0243atyof PERMIT REPORT Cdrlsbad Print Date: 09/12/2023 Permit No: FPC2018-0243 Job Address: 6018 GATEWAY DR, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: Track #: Applied: 07/30/2018 Valuation: $0.00 Lot #: Issued: Occupancy Group: Project #: DEV12023 Finaled Close Out: 09/13/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: One. Plan Check #: INSPECTOR: Wong, Cindy Plan Check #: Project Title: UPTOWN BRESSI RANCH Description: UPTOWN BRESSI -UNDERGROUND BLDG #15 Applicant: FPContractor: CAL-WEST FIRE PROTECTION SPECIALIST CAL-WEST FIRE PROTECTION GONZALO PENA 8361 COMMONWEALTH AVE 8361 COMMONWEALTH AVE BUENA PARK, CA 90621-2525 BUENA PARK, CA 90621-2525 (714) 912-4552 (714) 912-4552 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $625.00 Total Fees: $625.00 Total Payments To Date: $625.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov - - - Fire Protection by Computer Design Cal-West Fire Protection 1113 N Gates St. Santa Ana, Ca. 92703 866-374-9378 Job Name : Uptown Bressi "Bldg. #15" Building Location : El Fuerte St. & Gateway Rd. System Contract : 18-099 Data File : Bldg. - 15.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C Cal-West Fire Protection Page Uptown Bressi "Bldg. #15" Date 7.19.18 City Water Supply: Demand: Cl - Static Pressure : 100 Dl - Elevation : 1.516 C2 - Residual Pressure: 20 D2 - System Flow : 500 C2 - Residual Flow : 2500 D2 - System Pressure : 16.582 Hose ( Demand) D3 - System Demand : 500 Safety Margin : 79.344 150 140 130 p120 R 11 Cl E10° ZZ S 90 U 70 R60 E 50 40 30 C2 : 30600 900 1200 1500 1800 2100 2400 2700 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Cal-West Fire Protection Uptown Bressi "Bldg. #15" Page 2 Date 7.19.18 Fitting Legend Abbrev. Name ¼ % 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zif Febco 876V Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Prssure I Flow Summary - STANDARD Cal-West Fire Protection Page 3 Uptown Bressi "Bldg. #15" Date 7.19.18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. BOR 0.5 0.0 na 500.0 UGI -3.0 2.89 na UG2 -3.0 5.37 na UG3 -3.0 13.96 na SRC -3.0 16.58 na The maximum velocity is 12.15 and it occurs in the pipe between nodes UG2 and UG3 Computer Programs by Hydratec Inc. Revision: 50.52.1 - Fir'al Calculations - Hazen-Williams Cal-West Fire Protection Page 4 Uptown Bressi "Bldg. #15" Date 7.19.18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 500.00 4.26 E 13.167 12.000 0.0 Qa = 500.00 to 120.0 0.0 13.167 1.516 UGI 500.0 0.0545 0.0 25.167 1.372 Vel = 11.25 UGI 0.0 4.23 2E 38.446 28.000 2.888 to 150.0 0.0 38.446 0.0 UG2 500.0 0.0373 0.0 66.446 2.481 VeI= 11.42 UG2 0.0 4.1 3E 49.537 10.000 5.369 to 150.0 Zif 0.0 49.537 6.000 * * Fixed Loss = 6 UG3 500.0 0.0435 0.0 59.537 2.588 Vel = 12.15 UG3 0.0 4.23 G 3.845 28.000 13.957 to 150.0 T 38.446 42.290 0.0 SRC 500.0 0.0373 0.0 70.290 2.625 Vel = 11.42 0.0 500.00 16.582 K Factor = 122.79 Computer Programs by Hydratec Inc. Revision: 50.52.1 PH HAH WAFER CHECK VALVE WEIGHTS 4 6 8 Lb Lb 15.75 22.50 36.50 7.14 10.21 16.56 C-1 WAFER CHECK VALVES [Mueller Ca..1 UL /FM Rev. 2-03 FIRE PROTECTION PRODUCTS A-21 02 Wafer Check Valve 4", 6", 8" 175 psi (1207 kPa) Working Pressure 350 psi (2413 kPa) Test Pressure Listed by Underwriters Laboratories, Inc. and Approved by Factory Mutual Research Corporation. PARTS LIST Catalog Parts Description Number Material Material Standard CW-1 Seat Ring Cast Bronze ASTM B584 CW-2 Body Cast Iron ASTM A126 CW-3 0-Ring (2 req'd) Buna-N ASTM D2000 CW-4 Clapper Cast Bronze ASTM B584 CW-5 Bushing (2 req'd) Brass ASTM B16 CW-6 Spring Stainless Steel Type 302 CW-7 Hinge Pin Stainless Steel Type 303 CW-8 Seal, Seat EP Rubber ASTM D2000 CW-1 CW-8 DIMENSIONAL INFORMATION FOR WAFER CHECK VALVES DIMENSIONS _____ A In. (mm) B In. (mm) C In. (mm) D In. (mm) E In. (mm) E Size 4 3.75 (95) 1.34 (34) 6.88 (175) 3.00 (76) 4.03 (102) 6 3.75 (95) 1.53 (39) 8.75 (222) 4.56 (116) 6.06 (154) 8 4.25 (108) 1.92 (49) 1 11.00 (279) 1 6.00 (152) 1 7.98 (203) WAFER CHECK VALVE ORDERING INFORMATION Specify: Quantity, Size and Catalog Number. WAFER CHECK VALVE PARTS ORDERING INFORMATION Specify: Quantity, Catalog Number, Part Name, Size of Valve, Catalog Number of Valve and Year Date of Valve. Page C-i -6 c C4 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Sprouts Farmers Market SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 6217 El Fuerte St CITY: Carlsbad PHONE: ( 714) 914-4552 (Cal-West Fire) FAX NUMBER:( 714 ) 912-4641 Largest Building (ft.2): 26,000 Sprinkled? Yes Construction Type: UNK SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): El Fuerte St north of Gateway Rd TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 129 PSI Hydrant Number (if applicable):H20910 Elevation of test: 402 Feet Main Size: 24 INCH Pressure Zone: 700 Feet Date/lime of Test: Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 8.000 GPM Residual Pressure 110 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer R.Mael.P.E. Eng. Lic. No. (if applicable): C69606 / / / Signature_____________________________________ Title/Org(diectManager Date: 01/11/2018 Legend w_Hydrant v Pipe ZONE $ 8 -550 -700 rAb Wv 30. 8. Jo- 11' 4 F] --1 GArEwAYRD 12 a co 12 LEIGHTON CR I _! IIR77NGTON WY ALAMEDA CR HANCOCK Fire Flow Test Location H20910 12. $ Sprouts Farmers Market - Fire Flow Analysis MJ Accessories ANSI/AWWA C11I/A21.11 O.D. I. B.C. -I Mj UUILS) GLANDS ,Cz ID BC 2 4 8 10 12 6.12 69 9.12 062 062 0.75 118 13 1.50 - 163 1.7S 175 1.75 340 484 5.92 802 10.1 - 7 ..1'2 1432 1640 ,, 18.50 20.60 - 22.70 2690 3329 4579 261 40 490 475 619 - 7_50 9.50--- 11 75 1400 - 16.25 * 1875 21.00 * 23.25 25.50 3000 3688 00.75 2 - 4 - 6 6 54 1 00.88 ö8 00.88 5 6 - 10 - 14 ir1i 088 1.00 '00 9 IS 13.37 =15.62,.100 - 1.00 1..5 131 1.38 1 44 6 200 2.00 0200 1120 13.30 1544 17.54 19.64 21.74 - '94 31.17 - 0088 00.88 0088 0088 00.88 8 8 20 - 24 45 ss 55 66 90 220 288 1788 14 16 - 20 24 30 - 42 - 2025 22.50 - '00 206 10 12 :12 14 16 20 28 13 286 - 213 2.19 231 275 27 27.00 39.12 53.12 0088 00 8 0113 39 j 435 8062 01.38 2.75 44.67 ;._ j'S2.O '..'-1 37-50' 38 W 4O0 B.C. 1" ID. C MI OVERSIZE GLANDS ir- C BOLT HOLE TT BOLT 4 9.12 0.75 1 sO 59' 5.10 750 00.88 4 3 6 1112 - 088 163 80' 720 950 6 5 8 1337 ' IS62 100 1.00 1 " . ITh - 101' -12..2j 9413 1130- 11.73 -14.00 00.88 6 6 8 10 ø0.88. 8 12 17.88 1.00 1.75 -i:3r 2.o6-J83O -à 14.32 1860 16.25 00.88 8 12 9 14 - ___16R2 .17.94___l2Ló 88 UCAT.I4rn TRADEMARK A •REGIsTEREDADEMARKOFSTARPIPEPRODUcrS STAR PIPE PRODUCTS RI HOUSTON CORPORATE TOLL FREE 1180499.34)9 FAX 28I.S5.9Eoo wwwataplpcproductcom Page 15 ~0,~ JMagIe Building essentials for a better tomorrow BLUE BRUTE TM SUBMITTAL AND DATA SHEET jFOR" PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) I APPROX. D9 JAIPPROX. (IN) WEIGHT (LBS/FT) PRESSURE CLASS 165 psi (DR 25) 4 4.80 4.39 0.192 5.25 5.57 1.9 6 6.90 6.31 0.276 6.40 8.00 3.9 8 9.05 8.28 0.362 7.05 10.50 6.7 10 11.10 10.16 0.444 8.20 12.88 10.1 12 13.20 12.08 1 0.528 8.80 15.31 1 14.4 PRESSURE CLASS 235 psi (DR 18)* 4 4.80 4.23 0.267 5.25 5.87 2.6 6 6.90 6.09 0.383 6.40 8.43 5.3 8 9.05 7.98 0.503 7.05 11.06 9.2 10 11.10 9.79 0.617 8.20 13.57 13.9 12 13.20 11.65 0.733 8.80 16.13 1 19.7 PRESSURE CLASS 305 psi (DR 14)* 4 4.80 4.07 0.343 5.25 6.17 3.2 6 6.90 5.86 0.493 6.40 8.87 6.7 8 9.05 7.68 0.646 7.05 11.63 11.6 10 11.10 9.42 0.793 8.20 14.27 17.6 12 1 13.20 1 11.20 0.943 1 8.80 16.97 1 25.1 Consult JM Eagle' for CSA and other listing availability prior to shipment. Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. Contact your JM eagleTM sales representative for location availability. O.D. E I.D. : Inside Dameter O.D. : Outside Diameter T. : Wall Thickness 09 : Bell Outside Diameter E: Distance between Assembly Mark to the and of spigot. Assembly Mark Product Standard: ANSI/AWWA C900 Pipe Compound: ASTM D1784 Cells Class 12454 Gasket: ASTM F477 Integral Bell Joint: ASTM D3139 Certifications: ANSI/NSF Standard 61 UL Standard 1285 Pipe Length: 20 feet laying length Installation: AWWA C605 JM Eagle Installation Guide JM EagleTM also manufactures this pipe in green for sewer force main applications and purple, specifically for reclaimed water systems. This pipe is made to the same requirements as our standard products. The only difference is that the pigment used is green or purple. These products will not be marked with UL or NSF listing marks. Additionally, the green pipe will be marked "Forced Sewer" and the purple pipe will be marked: "Reclaimed Water... Do Not Drink." ES-F-LF876V Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative - MasterSeries® LF876V Double Check Detector Backflow Prevention Assemblies (Type II) Size: 2½" - 8" (65mm - 200mm) The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This Backfiow Assembly is primarily used on potable drinking water systems and fire sprinkler systems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal "N-Pattern" Installations Vertical-Up "Z-Pattern' Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1st & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4 Backfiow Assembly No Special Tools Required for Servicing Field Replaceable Seats & Discs Detect Potential Underground Water Leaks Detect Unauthorized Water Usage Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL/ FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by AWINA Standard 0510. The auxiliary bypass line contains a %x~" Water Meter that complies with ANSVAWWA Standard 0700 coupled With an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of AWNA Standard 0510 flow and pressure loss performance parameters. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. iT1111D1 Inquire with governing authorities for local installation requirements "The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. FEBCO product specilicetions in U.S customary units and metric are appidmate and are provided for reference only. For precise measurements, please =W FEBCO Technical Service. FC0 reseives the right to change or modify product design, mristnucticn, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and moditicationson FEBCO products previously or subsequently sold. A WAllS Brand Options - Suffix OSY: ULJFM Approved OS&Y Gate Valves [ANSI/AWWA C515 Compliant] CFM: Totalizing Cubic feet/mm %"x 3/4" Water Meter [ANSI/ AWWA C700 Compliant] GPM: Totalizing Gallons/mm %"x 3/4" Water Meter [ANSI/ AWWA C700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4" LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4" LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer FDA Approved [ASME B16.1 Class 125 & AWWA Class D flange] Series 611 Valve Setter. MJ x MJ - Mechanical Joint x Mechanical Joint [AWWA C1 1/A21.1 1] MJ x FL - Mechanical Joint x Range [AWA Cl 11/A21.11; ASME B16.1 Class 125/AWWA Class D Range] FL x FL - Range x Range [ASME B16.1 Class 125 & AWWA Class D flange] Materials Below is general materials list of the Model LF876V. PJI assemblies size 21h" through 8" is similar in materials and construction. Please contact your local FEB00 Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AWWA C550-90 Shutoff Valves: OSY resilient wedge gate valve AWWA C515 (IJLIRvI) Check Seats: Stainless Steel Disc Holder: Stainless Steel Elastomer Disc: Silicone Spring: Stainless Steel Clamp: AWWA 0606 Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [FCCCHR-USC] ASSE 1048 Usted **UL Classified [US & Canada] **FM Approved IAPMO/cUPC AWWA Standard C510 Compliant End Connections: Compliant to ASME B16.1 Class 125 & AWWA Class D Range —Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21h' —8") - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC Vertical Up (Z-Pattern 2'h"- 8 - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC 4 C sec Appfand Z c®us 1048 B64.5 Pressure - Temperature Max. Working Pressure: 175p5! (12.1 bar) Mm. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350p5i (24.1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous Dimensions - Weights Size: 21/21' - 8" Below are the nominal dimensions and physical weights for the Modal LF876V size 21h' through 80. Allowances must be made for normal manufacturing tolerances. Please visit our websfte to download a copy of this productIs installation instructions, or contact your local FEBCO Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) I' Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V SIZE (ON) - - - DIMPSONS - - -- - wEIGHr1 in. mm A in. mm B ft mm C in. mm D in. mm E in. mm F in. mm G in. mm H in. mm I in. mm J in mm K° in. mm L I in. mm OSY lbs. kg. 21h 65 291A 740 121h 318 61/4 159 251/4 642 171h 445 13% 346 271/4 692 5½ 140 111A 283 3½ 89 16% 416 111h 292 216 98 3 80 291A 740 121h 318 61/4 159 25% 654 17% 451 14½ 359 281/4 718 51h 140 111A 283 A 95 221/4 565 111h 292 242 110 4 100 31½ 791 14 356 7 178 27% 705 18% 476 151h 394 31 787 6 152 11½ 283 41h 114 231/4 591 13 330 347 157 6 150 35% 908 16 406 8 203 32Y4 831 221h 562 18% 473 371/4 948 71/4 184 1121h 316 51h 140 1 301A 765 13 330 529 240 8 200 40% 10351181h 470 1 91A 235 36% 933 527 1 411h 10541 81h 216 114 356 1 6% 172 373/4 959 1 141h 368 1 827 375 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) Indicates weight of complete Backflow Assemblies with specified Gate Valves 6" LF876V psi Service Flow Rated Flow *UL Rated Row 16 is 14 I I I I I I ic I I I 6 I I 2 e I. 0 200 400 600 000 1000 1200 1400 1600mm 757 2271 3785 5300 1pm 7.5 11.4 17.0 fps 8" LF876V Psi Service Flow Rated Flow *UL Rated Flow I8 is 14 12 2 io 20'8 8 5... 6 0 o 400 No 1200 1600 2000 2400 gpm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps 4" LF876V Psi Is 16 14 12 2 10 8 8 5... 4 0 N Performance Row capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5s. AWWA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than 1 Ofps. UL flow rate is determined by typically rated Velocity of 15 feet/sec. Capacity N-Pattern 2W LF876V PSI Service Flow Rated Flow IlL Rated Flow 32 20 is 12 io TT TTTTJ 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350gpm 284 568 852 1138 10m 7.5 14.7 22.0 fps 3" LF876V PSI Service Row Rated Flow Ill Rated Row 32 50 5 IS r - 14 r - O 12 r ME 10 0.. - 50 100 150 200 250 300 350 400 450 500 gpm 379 757 1136 1514 10M 75 14.5 22.0 fps Pipe Support (furnished by customer) for valve weight only. valw Orientation "Z-Pattern Row One Standard Orientation "N-Ptittenf Raw curve N 0 150 220 300 400 500 600 700 800gpm 379 1136 1893 2650 1pm 7.5 122 19.1 fps A WArTS Brand USA. Tel: (800) 767-1234 • Fax: (800) 788-4491 • FEBCOonhine.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • FEBcoonline.ca Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBCOonhine.com ES-F-LF876V 1515 02017FEBCO ES-A-InBuiIdingRiser Series IBR A A M E S In-Building Risers FIRE Sizes: 4" — 10" (100— 250mm) = Features Cost savings Corrosion resistant stainless steel construction, type 304 Ease of installation and light weight allows one person to position and handle the riser Minimal site preparation; joint restraint one-piece construction reduces time and labor; no missing parts, no leaks; easily identifiable for approvals Includes Test Cap and Coupler UL/FM approved Sizes: available in 4" — 10" (100-250mm) with various lengths to meet all local requirements Designed to meet NFPA 24-2007 Section 10.6.5 AWWA C900 Inlet/DIP AWWA C606 Outlet Job Name Job Location Engineer Approval Series IBR In-Building Risers are used to connect the main fire supply to the building overhead fire system. The fitting passes under the foundation without joints and extends up through the floor. Provided with installation tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connec- tion to the underground supply (AWWA C900 PVC and Ductile Iron Pipe) and industry standard grooved-end connection (AWWA C606) on the building side for easy connection to the overhead fire sprinkler system. Ames In-Building Risers are precision engineered and manufactured to provide exceptional reliability and reduce installation time & labor costs associated with field assembly. In accordance with NFPA 24-2007, the ULJFM approved In-Building Risers replace numerous fittings, elbows & spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation. The use of stainless steel signifi- cantly increases the reliability and life of the riser. *The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.250/6) of lead by weight Contractor______________ Approval Contractor's P.O. No. Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the fight to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Specifications Standards In-Building Riser shall be installed as indicated on the plans. Riser shall be composed of a single extended 90 degree fitting of fabricated 304 stainless steel tub- ing, maximum working pressure 200psi (14 bar). The fitting shall have a grooved-end connection on the outlet (building) side and a CIPS coupler on the inlet (underground) side. The grooved end shall include a coupler and cap to facilitate testing of the underground piping. The In-Building Riser shall be an Ames Fire & Waterworks Series IBR. Approvals Fittings FM class 1920 UL HKQA (4-10") <15W& Dimensions - Weights A Grooved End J [f'" (Flange Optional) J- CIPS Coupling Tie-Rod Bracket I c in. mm A(OD) in. mm B ft cm C ft cm tbs. kg 4 100 4½ 114 6 183 6 183 71 32 6 150 6% 168 6 183 6 183 98 44 8 200 8% 219 1 6 183 6 183 129 59 10 250 1 1034 273 1 6 183 1 6 183 1 202 92 Consult factory for custom leg dimensions. NFPA - Designed to allow the contractor to conform to NFPA 24-2007 Section 10.6.5: Where a riser is close to building foundations, under- ground fittings of proper design and type shall be used to avoid pipe joints being located under the foundations. NFPA 24-2007, 10.1.1, 10.6.7 End Connections Horizontal End: Mates with Ductile Iron Pipe and AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe Equivalent OD's) Utilizes Gasket conforming to UL 157 with "Lock in" gasket configuration .1P5lu1 MATING PIPE Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe Meets AWWA C-207 class D for flanges in. mm in. mm 4 100 4.8 122 6 150 6.9 175 8 200 9.1 230 10 250 11.1 282 Ratings Meets AWWA C-900 pressure class 200, DR 14 Pipe Testing Welds are 100% leak tested at the factory SIZE •DESIGN lPROOF PRESSURE in mm psi bar 4 100 1000 70 6 150 1000 70 8 200 800 56 10 250 BOB 56 IMPORTANT Inquire with governing authorities for local installation requirements. A 0 A M E S FIRE&WATERWORICS www.amesfirewater.com A Watts Water Technologies Company USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 • 1: 916-928-0123 • F: 916-928-9333 Control Valves- 18550 Hansen Road • Houston, TX 77075 • 1: 713-943-0688 • F: 713-944-9445 Canada: 5435 North Service Rd. • Burlington, ONT. L71L 5H7. 1:905-332-4090 • F: 905-332-7068 ES-A-lnBuildingRiser 0935 0 2009 Ames Fire & Waterworks PACIFIC STATES co CAST IRON PIPE COMPANY DIVISION OF MWNE. INC. P.O. BOX 1219, PROVO, UTAH 84603 TELEPHONE (AREA CODE 801) 373.6910 In each of the following, standards are developed by committees consisting of consumer, general interest and manufacturing members: American National Standards Institute (ANSI) American Water Works Association (AWWA) American Society for Testing and Materials (ASTM) Underwriters Laboratories (UL) MH16433(N) National Fire Protection Association (NFPA) National Sanitation Foundation (NSF) 61-1989 Factory Mutual (FM) J12VOA8.AH For ready reference, standards for ductile iron pipe are listed below: Standard Desi!nation ANSI/AWWA C150/A21.50 ANSI/AWWA C151/A21.51 ANSI/AWWA C11O/A21.1O ANSI/AWWA Cl 53/A21.53 ANSI/AWWA C111/A21.11 ANSI/AWWA C115/A21.15 ANSI/AWWA C104/A21.4 ANSI/AWWA C105/A21.5 & ASTM A674 ANSI/AWWA C600 ASTM A746 NFPA Outside Protection 24 Subiect Covered Design Water Pipe Fittings - Cast Iron Fittings - Ductile Iron Rubber - Gasket Joints Flanged Pipe Cement - Mortar Linings Polyethylene Encasement for Ductile Iron Pipe Installation Gravity Sewers Fire Protection Piping Pacific States ductile iron pipe meets and exceeds the requirements of all of the above national standards relating to pipe manufacture and performance. PACIFIC STATES CAST IRON PIPE COMPANY DIVISION OF McWANE, INC. P.O. BOX 1219, PROVO, UTAH 84803 TELEPHONE (AREA CODE 801) 373-6910 FAX: (801) 377-0338 EMAIL: sales©pscipco.com WEBSITE: www.pscipco.com Thickness, Dimensions and Weights of Mechanical Joint Ductile Iron Pipe by Size for Each Thickness. Nominal Wt. of Barrel Mechanical Joint Wt. .of Wt. Per Avg. Wt. Thickness Thickness OD* Per Ft. t Bell Lgth.t Per Ft.* Size Class In. In. Lb. Lb. Lb. Lb. 3 53 .31 3.96 10.90 11 230 11.4 4 53 .32 4.80 13.80 16 290 14.6 6 53 .34 6.90 21.40 18 405 22.4 8 53 .36 9.05 30.10 24 565 31.4 10 53 .38 11.10 39.20 31 735 40.9 12 1 53 1 .40 13.20 49.20 37 925 51.3 tincluding bell; calculated weight of pipe rounded off to the nearest 51b Tolerances of OD of spigot end; 3-12 in. 0.06 in. Including bell; average weight per foot based on calculated weight of pipe before rounding. 1 t KLNNLL A DIVISION OF MCWANE, INC I A T PROUD LY& :( -MADE IN ELMIRA, NEWYORI~,*Y~~ _i• ~ .(-• 1• ;•• •• :-.- ,: .: -•; (Rvisod 03:272011) • lODELKSFWEd ' LV. ! -'• -• :•• r During the decade of the 1980's, the waterworks industry was introduced to the Resilient Seated Gate Valve, a design principle that is dominant in preference for use in distribution systems. Kennedy Company was at the forefront in this industry-wide movement by introducing the Ken Seal Series, our AWWA C509 Resilient Seated Gate Valve. In 2002, with the end user in mind, Kennedy redesigned the Ken Seal Series introducing the model KS-FW. The goal of the redesign was to eliminate the customer need for any anti- rotational bolts. Kennedy did this by designing a machined elliptical bolthole in place of an as-cast opening. This elliptical design allows valve installers to slide a standard sized bolt Into the slot, therefore eliminating the need to have two different types of bolts on the installation. RECOMMENDED SPECIFICATIONS FOR C-509 CAST IRON RESILIENT WEDGE GATE VALVES KENNEDY VALVE COMPANY Valves shall conform to the latest revision of AWWA Standard C-509 covering resilient seated gate valves for all water supply service. The valves shall have a cast iron body, bonnet, and 0-ring plate. The wedge shall be totally encapsulated with rubber. The sealing rubber shall be permanently bonded to the wedge per ASTM D429. Valves shall be supplied with 0-ring seals at all pressure retaining joints. No flat gaskets shall be allowed. Blind bolts shall not be allowed. The valves shall be either non-rising stem or rising stem, opening by turning left or right, and provided with 2" square operating nut or a handwheel with the word "Open" and an arrow to indicate the direction to open. Stems for NRS assemblies shall be cast bronze with integral collars in full compliance with AWWA. OS&Y (rising stems) shall be bronze. All stems shall operate with bronze stem nuts independent of wedge and of stem (in NRS valves). Stainless stems are available but not standard. NRS stems shall have two 0-rings located above thrust collar and one 0-ring below. Stem 0-rings shall be replaceable with valve fully opened and subjected to full pressure. The NRS stems on 2"-12" shall also have two low torque thrust bearings located above and below the stem collar to reduce friction during operation. Waterway shall be smooth, unobstructed and free of all pockets, cavities and depressions in the seat area. Tapping valves 4" and larger shall accept a full size tapping cutler. The body, bonnet, and 0-ring plate shall be fusion-bond epoxy coated, both interior and exterior on body and bonnet. Epoxy coating shall be NSF 61 certified and applied in accor- dance with AWWA C550. Each valve shall have manufacturers name, pressure rating, and year in which it was manu- factured cast in the body. Prior to shipment from the factory, each valve shall be tested by hydrostatic pressure equal to the requirements of AWWA C-509 (and UL/FM where applicable). Valves shall have all component parts cast and assembled in the USA and shall be manufactured by the Kennedy Valve Company. (Revised 03.27.2011) Features and Benefits DELRIN THRUST BEARINGS ABOVE AND BELOW THE THRUST COLLAR REDUCE FRICTION AND MINIMIZE OPERATING TORQUES LONG, TROUBLE FREE LIFE WITH HIGH STRENGTH, NON-CORRO- SIVE BRONZE STEM AND STEM NUT. 1 ALL NRS STYLE VALVES ARE STAIN- LESS THE OPERATING MECHANISM IS TRIPLE 0-RING SEALED TO COMPLETELY SEAL AGAINST LEAKAGE PAST THE STEM. TWO 0-RINGS ARE PROVIDED ABOVE THE THRUST COLLAR AND ONE BELOW. UPPER 0-RINGS CAN BE REPLACED UNDER PRESSURE WITHOUT REMOVING THE STEM WHEN THE VALVE IS FULLY OPENED. O-RING SEALS AT STUFFING BOX AND BONNET TO BODY FLANGES TO ENSURE THE BEST POSSIBLE SEAL. NO FLAT GASKETS. 100% EPDM COATED WEDGE WITH TWIN SEAL DESIGN ENSURES BUBBLE- TIGHT SEAL UP TO 250 PSI EVERY TIME. ELLIPTICAL BOLT HOLE DESIGN ELIMINATES THE NEED FOR ANTI-ROTATION BOLTS KENNEDY CORROSION RESISTANT FUSION- BONDED EPDXY COATING, CONFORMING TO AWWA C-550 AND NSF61 CERTIFIED, PROTECTS BOTH INSIDE AND OUTSIDE OF VALVE. SMOOTH, UNOBSTRUCTED PADS ON THE BOTTOM OF FULL SIZE WATERWAY IS ALL VALVES KEEP VALVE FREE OF POCKETS, CAVI- IN UPRIGHT POSITION TIES, AND DEPRESSIONS FOR EASIER STORAGE ALLOWING FOR MINIMAL AND PROTECTION FROM FLOW LOSS AND LOWER THE ELEMENTS. PUMPING COSTS. ALL TAPPING VALVES ACCEPT FULL SIZE TAPPING CUTTER. ALL VALVES ARE RATED AT 250 PSI FOR AWWA SERVICE AND 200 PSI FOR ULFM SERVICE. ALL VALVES ARE HYDROSTATICALLY TESTED TO 500 PSI. 10 YEAR LIMITED WARRANTY (Revised 03-27-2011) 8571 8561 8057 8572 MECHANICAL JOINT ENDS FLANGED ENDS THREADED ENDS FLANGED X MJ 2' 12" 2 • 12' 2" • 30 3"" 12" 8597 8576 8901 8701 PUSH-ON FOR PVC MECHANICAL TYTON ENDS FLANGED ENDS 2'.81. CUTTING-IN JOINT PUSH-ON FOR (DI. & 0900) POST INDICATOR VALVE (PIV) 4" • 12" 4". 12" 3" • 12" 0 (0 8902 8950 8071 8068 FLANGED & TYVON JOINT TAPPING X MJ MECHANICAL JOINT FLANGED ENDS PUSH-ON FOR (0.1. & C900) TAPPING VALVE POST INDICATOR VALVE (PlY) OS&Y CONSTRUCTION 4" • 12" 4" • 12" 3" • 12" 2 112' • 12" A B C D E G H P Q P S U V No. of lums Jo Full Op- 2' 7 31/4 - 51/4 107/8 - - 3 - - 7 1/4 - - 43/4 2 1/2" 7 1/2 - - 7 11 3/8 - - 31/4 163/8 13 7/8 71/4 - - 51/2 3" 1 8 31/2 1 - 7 1/8 123/8 - 5 3/41 3 1/2 187/8 115 5/8 10 1 - - 10 4U 9 41/2 63/4 - 143/4 41/2 63/4 41/2 223/4 18 1/4 10 63/4 93/4 131/2 6" 10 1/2 5 77/8 - 19 5 1/4 7 3/4 5 301/8 233/4 12 75/8 113/16 19 1/2 8" 111/2 51/2 81/2 - 221/2 55/8 8 1/2 51/2 373/4 29 1/4 14 81/2 113/4 251/2 10" 1 13 7 10 - 261/2 7 10 - 453/4 5 /81 18 1 10 131/2 311/2 IT 1 14 6 3/4 111/4 - 30 8 1/2 1 107/8 1 - 53 1/8 1 40 5/8 1 18 1 11 14 3/4 37 3/4 KENNEDY VALVE A DIVISION OF MCWANE. INC. r~v www.kennedyvalve.com 2007 1021 E. Water Street Elmira, New York 14901 P.O. Box 981 Phone (607) 734-2211 Fax 1-607-734-3288 (Revised 03-27-2011) MJ Accessories ANSI/AWWA C111/A21.11 OD r E I BI ;I - F 2B for sizes 3-24in. 20 for sizes 30-60 MECHANICAL-JOINT GASKET w 2 230 048 -- -'--- 062 0.31 248 012 0.1-S 105 396 048 -012 01' -, 101 4 4.80 - 062 075 031 468 016 022 - 122 062 0S 031 67' - 016 -- 012 1.22 8 9.05 T 1110 062 - 062 073 075 031 883 108 , 016 016 022 021 1.22 112 io 0.317 12 13.20 062 073 031 1295 016 022 122 - 14 1530 Th 016 0.22 062 0 3i 16 17.40 062 075 011 1707 016 022 122 18 ---0'S 1913 - 16 022 I5O - 062 O31 12 20 - 2160 062 0Th 031 2120 6 2534 , 016 021 122 24 1560 - 062-- 7:,0 7s:..-: ,. 011 1.22 01 0 l6?; 016 30 3200 073 1.00 038 3147 037 154 36 3810 073 - 37.67 016, - 154 018 42 4450 073 1.00 038 438 016 037 1.54 48\ 380 - 0.73 0.16 7%5ThU 53 498 1.54 I ØD A T G L(H\Cf kF ___ TRANSITION MECHANICAL-JOINT GASKET I C(REF) SILE 5O.D... • -.,. .- -±13% .. 2 2.375 0.56 0.66 0.31 2.32 0.12 0.21 1.10 3 3.500 072 77 064 014 141 0 12 038 110 4 4.500 0.76 0.73 0.33 4.43 0.20 0.37 1.26 6 6.625 0Th 0'3 031 653 020 036 11 8 8.626 0.82 0.73 0.34 8.50 0.20 0.43 1.27 10 10750 - 079 07 OW 10.59 020 126 12 12.750 0.84 1 0.75 0.33 12.56 1 0.20 0.44 1 1.28 UCAT.I4DI O REGISTERED TRADEMARK OF STAR PIPE PRODUCTS ErAR PIPE PRODUCTS FM HOUSTONCORPOATE ThLLPREE I4EO499.3t*)9 PAX1SI.ssa.9000 wwwpIpq,odbom Page 17 MJ Accessories ANSI/AWWA C111/A21.11 1-Bolts, Double Ended Rods & Nuts HSLA STEEL SPECIFICATIONS: Bolts & Nuts are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1. Material is High Strength Low Alloy Steel per ANSI/AWWA C1 1/A21.1 1. Threads per ASME BI. 1 unified standard coarse (Class 2A & 2B) MECHANICAL PROPERTIES Yield Strength 45000 PSI (mm) Elongation in 2in. 20% (mm) CHEMICAL PROPERTIES Carbon 0.20% Max Manganese 1.25% Max Sulfur 0.05% Max Nickel 0.25% Mm Copper 0.20% Mm Combined 1.25% Mm (Ni. Cu, Cr) BLUE BOLT/NUT/ROD T-Bolts. Rods & Nuts have fiuoropolymer coating material which is VOC-compliant, resin-bonded, thermally cured and dry lubricant. COATING PHYSICAL PROPERTIES Film Thickness: Number of Coats: Adhesion: Cure Test: Pencil Hardness: Volatile Organic Compounds 0.3 to 0.4 mil per coat 3 to 4 coats 1 mm cross hatch test + 5 Pulls. Good knife resistance 50+Rubs with MEK. No substrate exposure Pencil Hardness: 4-6H 2.741b5/gal Stainless Steel 1-Bolts & Nuts ALLOYS SS 304 & SS 316 PER ASTM F593 SPECIFICATIONS: T-bolt dimensions are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1. T-bolt alloys SS 304 and S5316 per ASTM F593 Heavy Hex Nut Alloys SS 304 & SS 316 per ASTM F594. MECHANICAL PROPERTIES Tensile Strength: 85,000 PSI to 140,000 PSI Yield Strength: 45,000 PSI (mm) COATING SPECIFICATION Nuts have fluoropolymer coating material which is VOC-Compliant, resin-bonded, thermally cured and dry lubricant. COATING PHYSICAL PROPERTIES Film Thickness: 0.3 to 0.4 mil per coat • Pencil Hardness: 4-6H Number of Coats: 3 to 4 coats • Volatile Organic Compounds 2.74 lbs/gal Adhesion: 1 m cross hatch test + 5 Tape Pulls. • Continous use temperature - 356°F Cure Test: 50+ Rubs with MEK, no substrate exposure • Color: SS 304 is green, SS 316 is red UCArl4I REGISTERED TRADEMARK OFSTAP. PIPE PRODUCTS STAR PIPE PRODUCTS HOUEIDNCORPORATEITOLI.PREE I400.9S9.309 F4xa8I458.0 t,pIpp,d,I.,•m Page 18 "to AWWA MEMBER Accessories IN -- - T 11TT• ! MECHANICAL JOINT PIPE SIZE (IN) 'I1:(S]1.[S1tSUJ! BOLT SIZE RANGE' OF (IN) TORQUE (FT-LBS 2-3 5/8 45-60 4-24 3/4 75-90 30-36 1 100-120 42-48 11/4 120-150 -0-- fli - 1I8-in. Radius Maximm 'These torque ranges are requirements ofAWWA C600 rniu iuis STEEL) BOLT 'ui x 3 14X3½ iso 10 173 0.625 ff25 350 0.750 300 30 4.50 550 S50 600 -6 00 6.50 200 270 U 11 10 10 10 0.623 €L62)10j S O312 1.062 0.625 0.312 0.375 0.750 2.50 0.750 1.250 414 -14 x 4 - 1 1 0.750 0.750 ~1 7 00 3.00 0.750 1.250 0375 0.750 0375 1.75 2's 2 2 2.50 300 3.70 3.00 zr 1O 10 j 50 0375 'x5½ 0.750 1000 1000 1.250 0.750 1xS½ 1.000 ToW 1.250 8 1.625 1000 0SOO 1x6 _ 1¼x6½ 1.000 1.250 '1 230 0.500 0.625 7 1O 1.250 ' 000 3.50 2.000 1t44W 3T - fÔb) 1:25T W0525_4 IIflESITATIONT- HEAD (LOW ALLOY1U L) BOLT 'IM NOM HREAD s F .141 TZE x3 150 0.625 300 200 063 11 0.625 1.062 0.625 0.312 5*x3,½ - --.- " 150. 175 iTTT- 0625 ' 350 350 400 " 2,30 250 29 . -063 063 : 0.750 ''.1062 1.250 ,",'' ,' 0625 0.31 0.750 0.375 .4 11 10 ~x3¼ 0750 - T 1250 0 037 V4 x4 ½ 1.75 0350 4.50 3.00 0.63 10 0.750 1.230 0.7.50 -- 0.375 - 100 0.63 10 ' 0375. UCAT.I4eI Agalmik gwIsrEREDTRADEMAJucOperAaPIpEpRODUcTs AV Ift bTAFV PIPE PRODUCTS irF .3 HOUSTON CORPORATE TOLL FREE I-8OG999-39 FAX 281-SSS-900 wpIppmñm.m Page 19 Nil x Nil BENDS BENDS (1/4) BENDS BEN 4~ DS 6 BENDS (1/32) LNOM..''1 SIZE A' (LBS) (LBS) T R T v'- (LBS) r. (LBS 2 0.39 3,25 2.26 14 1.80 1.96 13 1.80 4.02 13 1.80 8.12 13 3 048 0 400 88 800 30 300 1,S6 30 300 b25 .30 36' 4 0.52 650 4.50 55 4.00 4.81 50 4.00 10.06 50 4.00 20.31 50 6 0s 300 6008 00y'' 300l,06 7 500 3005'. 7.00 125 900 190 5.50 650 17.62 110 2 22.62 160 8 0.60 068 9.013 -(100 8.44 1088 110 15 5.50 5.50 6-10 35.50 110 10 6 0 7.50 13.25 12 0.75 12.00 10.00 255 215 7.50 27.62 220 7.50 55.81 220 14 11.50 340 - 720 .2 5,12 25 -TS- 0' 766 13.25 16 0.70 0.7516.50 15.00 12.50 430 14. 545 8.00 ''14.50' 340 420 8.00 8.S0'0.19 27.62 345 430. 8.00 8.50 55.81 345 60.94 430 .18 20 0.80 18.00 15.50 680 9.50 16.88 530 9.50 35.19 535 9.50 71.06 540 24 - 089 1812 s .-. 1100 3769 6 50'... - - 7612 70 -. 2200 180 1023 110081 1100 25.00 30 1.03 21.50 1690 15.00 27.75 1380 15.00 57.81 1400 15.00 116.75 1410 3500 2092 147 23 115 '21:00 24O 2472 1800 7288 33 00 42 1.28 T42 31.00 27.O 3410 3050 4595 21.00 42.23 2955 4080 21.03 - 86.00 10 3020 21.00 177.69 3035 48 3öi 4950 4170 400 20812 190 U -- • • I TA Nil x PE BENDS 901, Nil x PE 451, Nil BENDS I x PE 22 19.V4 SIZE T A, "''T''- (I,BNOW , B ..:. S.)A. ."1,1':,:i:. B, 15'TWT (IBS.), R (LBS.( ' A, ,B .R (LBS) 3 0.48 5.50 13.50 4.00 35 3.00 11.00 3.62 30 3.00 11.00 7.56 30 3.00 11.00 15.25 30 1 4 02 40 0 400 45 01006 45 U00 Al 400 6 0.55 8.00 16.00 6.00 80 5.00 13.00 7.25 70 5.00 13.00 15.06 70 5.00 13130 30.50 70 8. 0.60 . 0 1790 07.00 120 550 , 8.44 105 13.S0 17.62 106 , 50 50 35.50 i1055 6.50 10 0.63 11.00 19.00 9.00 190 6.50 14.50 10.88 155 14.50 22.62 160 6.50 14.50 45.69 160 12 0 5 0q 20 1000 28 '0 15 325 215 7 1S5, 220 1S 7.50. 15.50 25.12 260 7.50 14 0.66 14.00 22.00 11.50 325 7.50 15.50 12.06 255 15.50 50.75 260 'iThb 2 12O '400 800 5 L09- 070 320i : 19.00 37.69 24 0.99 13 22.00 2500 30.00 18.50 985 11.00 l500 19.00 18.12 715 127S 11.00 725 11.00 19.00 76.12 730 30 33"00 2300 =67S 13W 36 1.15 28.00 36.00 24.50 2310 18.00 26.00 35.00 1930 18.00 26.00 fl.88 1970 18.00 26.00 147.25 1980 'i 00,' 39 ' 2OO5 iO0( ' :--i-745 3 !iö" 100.: :!6 28 UCAT.I4DI REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STA R PWE PROD UCTS HOUONCORPORATEITOLLFREE I.EM.999.3009 F4X28L.555.9000 w.tpp.pMA.m Page 22 II GUARDIAN I im) FIRE EQUIPMENT, INC. DETAIL AND SUBMITTAL SHEET MIAMI, FIL Ph. 800.327.6584 • Fax 800.827.3869 6300 Series - Fire Dept. Inlet Connections - Bodies Project/Location: Date: Architect/Engineer: Qty: Contractor: ITIAppropriate Selection Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies. Provides 250 GPM flow (minimum), per 21/2" inlet. Two and three-way - inlet connections feature clappered brass bodies (straight or angle pattern), with female hose thread swivel inlets and female outlets. Cast brass construction, standard. 7Model I 0 6314' Outlet Back Two Pand Three-Way . 4"x 2V2" x 21/20 Connections IIr 1 51/2" I 81/8" El 6315* Angle 4"x 21/2"x 21/2" 1 81/6" 8/4' 6324 Back 4" x 21/2O x 2/" 2 71/4" 10h 2" 6325 Angle 4" x 21 2" x 21/20 2 81/4" 101/2" 6326 Back 6"x 21/2"x 21/2' 2 71/40 101/2" 6327 Angle 6" x 21/2" x 21/20 2 10" 101/2" 6336 Back 6 x 21/2" x 21/" x 21/2" 3 101/2" 13/4" 6337 Angle 6" x 21/2" x 2Vz" X 21/2" 3 111/2" 141/20 Body Lettering DAUTOSPKR DSTANDPIPE Blank (unlettered) *Auto Spkr lettering only Optional Finish: D-B Polished Brass Threads: 0-C Rough Chrome Plated 0 NST -D Polished Chrome Plated 0 Other Plugs with Chains and Break Caps - Used to keep fire dept. inlet connections free of debris and protect female threads. Contact factory for current listings and approvals Plugs with Chains Model No. I Size I Type ID 6404 Brass I Optional Finish: 0-B Polished -C Rough Chrome Plated 0 -D Polished Chrome Plated Break Caps 1 Model No. I size I Type 0 6406 2W' Aluminum 0 6407 211? 1 Plastic Threads: Adjustable Plugs DNST ModelirirNo. Size I Type 0 Other 0 6408 21/2" Aluminum '171 6409 21h' Plastic