Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2708 GATEWAY RD; ; FPC2017-0206
PERMIT REPORT Co C ity of Carlsbad Print Date: 09/12/2023 Job Address: 2708 GATEWAY RD, CARLSBAD, CA 92009-1730 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2132631100 Track #: Valuation: $358,824.65 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: C3 CHURCH BLDG 3 - FIRE ALARM Permit No: FPC2017-0206 Status: Closed - Finaled Fire Alarm Applied: 07/24/2017 Issued: 08/21/2017 Finaled Close Out: 09/13/2021 Final Inspection: INSPECTOR: Stowe, Daniel Fieri, Dominic FPContractor: LOW VOLTAGE FIRE INC 1090 JOSHUA WAY, # UNIT A VISTA, CA 92081-7800 (760) 598-4110 FEE AMOUNT FIRE New Alarm System $1,227.00 FIRE Reinspection (per inspection) --- $187.00 Total Fees: $1,414.00 Total Payments To Date: $1,414.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 I www.carlsbadca.gov FIRE ALARM SYSTEM SUBMITTAL L lá itcwg iritgrat Sys trns FIRE ALARM S SOUND DATA S MEDIA S SECURITYS CCTV S ACCESS CONTROL FIRE ALARM SYSTEM C3 KIDS CHURCH BLDG. C T.I. 3708 GATE WAU RD. CARLSBAD, CA 92008 FPC2017-0206 2708 GATEWAY RD FME-..-Cm-y-~ LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1930 WATSON WAY, STE L VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: CIO, C16 # 791832 PHONE: (760) 598-4110 FAX: (760) 598-4107 Low'ifoltage integrated systems MATERIAL LIST PART DESCRIPTION MANUFACTURER NFW2-100 FIRE ALARM CONTROL PANEL NOTIFIER CELLCOMSLCF CELL DIALER DMP FDU-80 ANNUNCIATOR NOTIFIER NOT-BG12LX PULL STATION NOTIFIER NP-100 SMOKE DETECTOR NOTIFIER D4120 DUCT DETECTOR SYSTEM SENSOR RTS-1 51 REMOTE TEST SWITCH SYSTEM SENSOR NMM-100P MINI MONITOR MODULE NOTIFIER NDM-100 DUAL MONITOR MODULE NOTIFIER PC2WL CEILING HORN STROBE SYSTEM SENSOR SCWL j CEILING STROBE SYSTEM SENSOR Low Voltage Integrated Systems, Inc. 1930 Watson Way, Ste L • Vista, California 92081 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA LICENSE NO. CIO, C16#791832 email: info @ sdlvis.com DN-60602:A1 Fire Warden-I 00-2(E) Rev 3 Intelligent Addressable FACP NOTIFIER® by Honeywell', General The Notifier FireWarden-100-2 Rev 3 (NFW2-1 00) with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The 's quick-remove chassis protects the electronics during con- struction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS, and increased power for the reset- table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local pro- gramming of the control panel using the PS-Tools Upload/Down- load utility. In addition, the control panel may be programmed or interrogated off-site via the public switched telephone network. Any personal computer with Windows® XP or greater, a com- patible modem, and PS-Tools—the Upload/Download software kit—may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard P5-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, NP-A100, USB port, NAC circuit diag- nostics, a new report has been added to the walk-test that lists untested devices, new, device types added: audio telephone type code for NFV-25/50ZST, Photo Supervisory and auto-reset- table Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term "Fire Warden-I00-2" is used in this document to refer to both the Fire Warden-I 00-2 and the Fire Warden-I00-2E FACPs (Fire Alarm Control Panels). Like- wise, "NFW2-100 refers to NFW2-100E as well. Features Listed to UL standard 864, 9th edition. On-board DACT. NA Remote site or local USB port upload/download, using PS- Tools Four (4) Style V (Class B) NAC circuits, which car, be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or FDU-80, N-ANN-80 or Legacy ACS Annunciators. ANN-BUS for connection to following optional nodules (cannot be ised if ACS annunciators are used): - N-ANN-80(-W) Remote LCD Annunciator - N-ANN-I/O LED Driver - N-ANN-S/PG Printer Module - N-ANN-RLY Relay Module - N-ANN-LED Annunciator Module - N-ANN-FILED Annunciator Module alarms only - ROME Relay Option Module Enclosure ACS & Terminal-mode Annunciators: - ACS Annunciators: Up to 32 Legacy ACM Series annuncia- tors (ACM-16AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. - Te-minal-mode Annunciators: Up to 32 _egacy FDU-80 annunciators. EIA-232 printer/PC interface (variable baud rate) on main cir- cuit board, for use with optional UL-listed prin:er PRN-6. Integral 80-character LCD display with backliçhtirg. Real-time clock/calendar with automatic daylight savings control. DetEctor sensitivity test capability (NFPA 72 compliant. DN-60602:A1 • 12/0712010 - Page 1 of 6 History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accumu- lation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 rn). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using out- put control modules (NC-lOG). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (NFW2-100 requires PS-Tools Programming software, avail- able on www.magni-fire.com). Upload/download system pro- gramming locally to the NFW2-100 Rev 3 in less than one minute. USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information NFW2-100: FireWarden-100-2 Rev 3 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. NFW2-100R: Same as NFW2400, except in a red backbox. NFW2-100E: Same as NFW2-100, except with 240 VAC opera- tion. 4XTM Reverse Polarity Transmitter Module: Provides super- vised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style Y (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PS Tools: Programming software for Windows®-based PC computer (cable not included), available on www.firelite.com. DP-9692B: Optional dress panel for FireWarden-100-2 Rev 3. TR-CE-B: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid batter- ies with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E Rev 3. PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download program- ming and updating panel firmware. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-212UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- net internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DN-60408 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: V-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPA TIBLE ANNUNCIATORS N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W version for white; see DN-7114.) Page 2016— DN-60602:A1 • 12/07/2010 N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red or black enclosure (see DN-60242). N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242). N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DN- 7107.) ROME-B: Relay Option Module Enclosure (order ROME-13 for black or ROME for red). Provides one N-ANN-RLY Relay Mod- ule already installed. The ROME Series provides mounting space for one additional Relay Module or one addressable Multi- module. (See Installation Sheet PN 53530.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.) ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDLJ-80 (Liquid Crystal Display) point annunciator: 80-char- acter, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 3, see the following data sheets (document numbers) ACM-8R (DN-3558), ACS/ACM Series (DN- 0524). LDM Series (DN-0551), FDU-80 (DN-6820). COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-100T.- Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W) duct smoke detector housings. NH-11 00: Fast-response, low-profile heat detector. NH-1100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100: Addressable low-profile multi-sensor detector. DNR: lnnovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order NP-bOA separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0(10.16cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style 0 (Class A) bC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only lDCs. NMM-i0OP: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0' (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cm.) box, surface mount using the SMB500. NOT-BG1 2LX: Addressable manual pull station with interface module mounted inside. N100-lSO: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 oper- ation). SMB500: Used to mount all modules except the NMM-100P. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 1313-25. NZM-1 00-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a B13-25. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-100-2 Rev 3, see the following data sheets (document numbers): N100-IS0 (DN-6994), NP-100 series (DN-6995), NI-100 (DN-6996), NH-100 series (DN-6997), ND-100 series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-I00P/ NDM-100/NZM-100 (DN-6999), NC-100/7VC-I0OR (DN-7000), NOT-BGI2LX (DN-7001), NMM-100-10 (DN-6990), and NZM- 100-6 (DN-60150). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. DN-60602:A1 • 12/07/2010 - Page 3 of 6 EIA-232 INTERFACE (PIM-24) built into the motherboard ANN-BUS or EIA-485 in ACS mode (two wires) FireWarden-100-2 Rev 3 Fire Alarm Control/ Communicator Optional REVERSE POLARITY! CITY BOX OUTPUT 41114444 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8R) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES ANN-BUS DEVICES N-ANN-80, N-ANN-LED, N-ANN-S/PG, N-ANN-I/O 24 VDC iE ANNUNCIATORS ACS/ACM, LDM NOTE: System can use either ANN-BUS devices OR ACS-mode annunciators. They cannot be used simultaneously. -, SMOKE DETECTORS NP-100, NP-100T, NI-1 00, NP-A100 No HEAT DETECTORS NI-I-100, NH-100R, NH-100H DUCT DETECTORS ND-100, ND-1100R, DNR Io - —* t. MONITOR/CONTROL NMM-100, NZM-100, NDM-100, N100-ISO, NC-100, NC-100R " ' I ~e I I I I I 1111111 .0 0. _-.0 ADDRSSABLE MULTI-MODULE NZM-1 00-6, NMM-1 00-i 0 EIA-485 INTERFACE (four wires) NOTE: System can use either the printer OR the FDU-80. They cannot be used simultaneously. 24 VDC MINI-MONITOR NMM-i OOP =LIJIJ FDU-80 Up to 6,000 ft. (1825.8 m) between each FDU-80 in the EIA-485 loop, and between each FDU-80 and the FACP. PULL STATION NOT-BG1 2LX Page 4 of 6— DN-60802:A1 • 12/07/2010 DN-60602:A1 • 12/07/2010 - Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits ......................................... 1 Addressable device capacity............................................198 Programmable software zones...........................................99 ACS Annunciators ..............................................................32 ANN-bus devices................................................................16 Electrical Specifications AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2 Rev 3(E): 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batter- ies require an external battery charger such as the CHG-75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block provides connections for two Style Y (Class B) for a total of four Style V (Class B) or with an optional ZNAC-92 module converts to four Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to panel documenta- tion and Notifier Device Compatibility Document for listed com- patible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps © 30 VAC (resistive). Form-C relays. Special Application Non-resettable Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each out- put. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a minimum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00' (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20 (13.34 cm.) deep. Trim Ring (TR-CE- B): 22.00 (55.88 cm.) high x 19.65 (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ±2% RH (non- condensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 271C/60 - 80°F NFPA Standards The FireWarden-100-2 Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprin- kler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100-2 Rev 3 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 FM approved CSFM: 7165-0028:0235 MEA: 120-06-E, Volume 2 For ULC-listed version, see DN-60600. NOTIFIER® is a registered trademark of Honeywell International Inc. Wheeloclg is a registered trademark of and ExcederTM is a trademark of Cooper Notification. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 933=1=1 U_ We cannot cover all specific applications or anticipate all requirements. i (ElffltN &aurciims All specifications are subject to change without notice. I I QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 6 of 6- DN-60602:A1 ° 12/07/2010 N FW2-100/FDU-80 Device Type Calculation Column 1 Primary (AC) Power Source Fire Alarm Current (amps) Calculation Column 2 Secondary (Battery) Power Source Fire Alarm Current (amps) Calculation Column 3 Secondary (Battery) Power Source Standby Current 'amps) Qy Xlcurrent draw]-- Total Oty X(current draM= Total Qty Xjcurrentdrawl Total MinCircutBoad x10.2751= 0.275 I ,0.1451= 0.145 I N-ANN-MG) I I X[D-045] . Xp.04•0• - - N-ANN-()LED I X(u.05BJ Xp.0581= - X0028P N-ANN-RLY - X(o.0751= - - Xfo.0751= - - I X0.015J= N-ANN-UO I I 1(10200? [ xjo200? N-ANN-SPG 1 1(10.045 xo.0451 - 40.0451= ACM-BR I I xP.15811. - - X10.I5B] - I ,qo.moi= ACM-thAT - - I I ACM-32A I x(o.05e- I I xjo.040.= AEM-ISAT - - xpoisj= - AEM-32A xa.oia= t I xo.002I= 1.FM.4SAT AFM-32A - I - I 1(D.*56= 1(10.055? _________________ 1 0045? AFM-ISA : : : X10.055 : : I 1(100251= LOM-32 - - ___________ X10.055I I - - X0.058I= - j - 3 X40.5401= LDM-532 f I XW.0181 — 1(10.015? 00021 FDU-B0 t — XIU.0541 — I lqo.oelj= j — I X0.025}_I FCPS-24S6 Calculate Column I Calculate Column 2 Calculation Column 3 Device Type Prmarç Non-Fire Alarm Current Primary Fire Alarm Current Secondary Non-Fire Alarm Current (amps) (amps) Qty X (current draw) = Total: Qty X (current draw) = Total: Qty X (current draw) = Total MainCircuft I X(OD91)= I XOi45]= 1 XO.O65)= Board 1 \ - in j . . . -.. . -. \N, Add cellular communications t any fire panel I Extend the Life and expand the capabilities of older panels by adding the power of advanced, digital cellular communication. With this simple communications add-on, almost every panel can take advantage of revenue-building remote system management and control features. Provide central station communication over cell for any burglary, commercial fire or residential fire panel Use Contact ID capture. 4 zones, or Bell Monitoring CellComSLCTM and CeLlComSLCF enables basic remote panel control via Virtual Keypad AppTM Provides end user alerts of arming/ disarming, alarm, and other events Add Z-Wave control of Lights, locks, and thermostats with CellComSLCZTM SYSTEM FEATURES Fully supervised universal alarm communication over CDMA Fully supervised universal fire alarm communication over COMA Program your own account number to easily workaround locked panels Contact ID dialer capture Four zones or Bell Monitoring Wiring for Ademco ECP Bus Communicates with DMP SCS-1 R and SCS-VR Receivers Builds customer loyalty: creates new RMR Armed/disarmed status LEO Private labeling available on the rubber logo insert ......... Two outputs : I SPECIFICATIONS CERTIFICATIONS Dimensions: 5.5" W X 3.75" H X 1 0 California State Fire Marshal (CSF Color: White Open-Collector Outputs: 2 ANSI/UL 1610 Central Station Bur Zones: 4 ANSI/UL 1023 Household Burglar Primary Power (CetlComSLC/SLCZ): 12VDC ANSI/UL 985 Household Fire War Pnmary Power (CeLlComSLCF): 24VDC ANSI/UL 864 Fire Protective Sign Current Draw. Alarm .181 mA I Cellular Standby .061 mA I FCC Part 15: MIVCNNO30 ORDERING INFORMATION CellComSL CellComSLC Universal Alarm Communicator FCC Part 1510: CCKP01 CellComSLCF Universal Fire Alarm Communicator IC: 5251 APc0159 CellCOmSLCZ .. Universal Alarm Communicator, Z-Wave ...... -------..----. -.- . L -E --- • - -': ... - 2500North Par éfh Z} (ORKS WITH MOST PANELS If the existing panel supports Contact ID, then it's a candidate for upgrading with the CellComSLC, CellComSLCZ, or CelLComSLCF. There are no issues with lockout codes. Simply add the CellComSL unit to the existing installation and program in your own account number. AVAILABLE BURGLARY COMMUNICATION The CellComSLC provides control of basic panel security functions and video. The CellComSLCZ adds the ability to remotely interact with Z-Wave devices, enabling a variety of home automation features including control of lights, door locks, thermostats and more. FIRE COMMUNICATION The CellComSLCF offers cellular fire communication on any fire control panel via Contact ID Captures or Zone Inputs. Meets NFPA 72 Standard for Single Communication Technology. MOBILE SYSTEM CONTROL With CellComSL communicators you can easily update your older residential and commercial customers to the latest cellular communication links. With cellular in place, end users can remotely access their panels via the Virtual Keypad AppTM. This makes it possible to use their mobile device not only to control basic arm/disarm functions and receive alerts, but also to control Z-Wave home automation devices for lights, door locks. thermostats, and more with CellComSLCZ. ENABLE VIDEO ON THE APP Video is no longer an expensive option. With the CellComSLC communicators, you can easily add up to six wireless cameras. Via the Virtual Keypad App, end users can do a remote visual survey of their premises to confirm an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION Provides a fully supervised alarm communication path for burglary control panels over the CDMA network providing higher speeds. CellComSL allows alarm messages to be communicated to an ScS-1 R orSCS-VR Receiver over the COMA network. COMA operates on the Verizon network. FIELD PANEL UPDATES The Model 400 USB Flash Module allows you to easily field update firmware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. SYSTEM PROGRAMMING System programming over cell via VirtualLinkTM includes zone information and Central Station communications. MULTIPLE CONNECTION OPTIONS CellComSL communicators can be attached to the existing panel in a variety of ways. It can capture Contact 10 messages from the dialer, or connect the four input zones from outputs on the panel; or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the Central Station. FOUR ZONES Each of the CellComSL models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. EASY UPGRADE FOR DIALER- ONLY PANELS Older, dial-up panels have new life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels. enabling them to increase the ROI on their system investment and build satisfaction with the purchase decision. SUIt.0 CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are less likely to switch systems and cancel their contract. When the time does come to replace the panel, they are more likely to rely on you. The app can be branded with your organization's Logo and contact information to provide a daily reminder of your services. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel via the App. :M) - th glar (Cellular) .5 - U — ning (CID Capture) = — ling Systems a = Cl — a — = 59 Cl tn = o 282"1dmp.com - d, Engineered & Manufacturec jfield ... Miouri. DN-6820:13 • D-123 FDU-80 80 Character Liquid Crystal Display General The FDU-80 is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the NOTIFIER Fire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and displays complete system point status information.. Up to 32 FDU-805 may be connected onto the EIA-485 termi- nal port of each FACP. The FDU-80 requires no programming, which saves time during system commissioning. Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. No programming necessary - FDU-80 connects to the ter- minal porton the FACP. Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time-and-date display field. Aesthetically pleasing design. May be powered from the host FACP or by remote power supply (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. Local piezo sounder with alarm and trouble resound. Semi-flush mounts to 2.188' (5.556 cm) minimum deep, three-gang electrical box (NOTIFIER PN 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER PN SBB-3 surface backbox. Operation The FDU-80 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU-80 also provides an array of LEDs to indicate system status, and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. NOTIFIER® by Honeywell - -- -, 68201d,,8.iflfl /7 Ordering Information FDU-80: 80 character, backlit, LCD Fire Annunciator with con- trol switches for remote control of system functions, and key- switch lock. FDU-80C: ULC-Iisted version; see DN-60573 for details. 10103: Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 MEA Listed: 245-00-E FDNY: COA#6038 CSFM: 7120-0028:209 FM Approved NOTE: For ULC-listed version, see DN-60573. DN-6820:B • 05/17/2010 - Page 1 of 2 NOTIFIER® is a registered trademark of Honeywell International Inc. @2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. Z 0 U = U 30 We cannot cover all specific applications or anticipate all requirements. 0111111011111 0111111011111 a 1100119=1 QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S.A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6820:B • 05/17/2010 N DN-7001:D • Al-380 NOT.BGI 2LX Addressable Manual Pull Station NOTIFIER® by Honeywell General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4' (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shapeand textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4(10.16cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The NOT-BGI2LX Addressable Manual Pull Station 7 The BG12TR is usually needed for semi-flush mounting with 4 (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the staticn, simply unlock the station with the key and pul the door open. This action resets the handle; clos- ing the dooi automatically resets the switch. Each manLal station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 99 on 4FW2-100/NFW2-100C, 1 - 50 for NFW-50/NFW- 50C). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored t• normal exc3pt oy ise of a key. An operated sta- tion shall aitomatically conciticn itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on ti-3 front of the sta:ior:s in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbc.x SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4(10.16 cT.) square electrical box, and shall be installed DN-7001:D.4/13/2012—Page 1 012 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. ULJULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E Vol. IV. CSFM: 7150-0028:0199. FM Approved. Patented: U.S. Patent No. 0428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® is a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. U U We cannot cover all specific applications or anticipate all requirements. mmmillimmmm All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2012— DN-7001 :D • 4/13/2012 DN-6995:C •A1-320 NP-100(A) Series NOTI Fl ER® Addressable Photoelectric Detectors - - for the FireWarden Series by Honeywell Addressable i General The NP.100(A), NP-100T(A) and NP-1100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series (FireWarden-100-2 and Fire- Warden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACP5). The NP-100T(A) adds thermal sen- sors that will alarm at a fixed temperature of 135°F (570C). Since these detectors are addressable, they will help emer- gency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capa- bility is available as an optional accessory, PN RA100Z(A). The NP-i OOR(A) is a remote test capable detector for use with DNR(A)/DNRW duct smoke detector housings. Features SLC loop Two-wire loop connection. Unit uses base for wiring. Addressing Addressable by device. Rotary, decimal addressing: 01 —99 with FireWarden-100-2 and NSP-25, and 01 —50 with FireWarden-50. Architecture Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0' (10.16 cm) octagonal box, or 4.0° (10.16 cm) square electrical box (using a plaster ring - included). Other system features Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Options Remote LED output connection, PN RA1 OOZ(A). NP-100(A) in B2IOLP(A) Base Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. NP-100(A) series plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation NP-1 00(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class B) wiring. NP-100R(A) mounts in a DNR(A)/DNRW duct detector housing. Operation Each NP-100(A) series detector uses one of 99 possible addresses on the FireWarden-1 00-2 and NSP-25, or one of 50 possible addresses on the FireWarden-50 Signaling Line Cir- cuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the NP-100(A) series has a unique unipolar chamberthat responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar cham- ber, the NP-100(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DN-6995:C • 12/07/2011 -Page 1 of 2 Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a FireWarden-100-2 or FireWar- den-50 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- Warden-50 for record keeping. Specification Standby current: 300 hA © 24 VDC. LED current: 6.5 mA © 24 VDC (latched ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Size: 2.1(5.33cm) high; base determines diameter. - B21OLP(A): 6.1(15.5cm) diameter. - B501 (A): 4.1(10.4cm) diameter. - B200SR(A): 6.875' (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100(A): 0°C to 49°C (32°F to 120°F); for NP-IOOT(A): 0°C to 38°C (32°F to 100°F). NP-100R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. Listings Listings and approvals below apply to the NP-100(A), NP- 100T(A), and NP-100R(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing sta- tus. ULLlsted:S1115. ULC Listed: S91 1. CSFM: 7272-0028:0231. MEA: 243-02-E Vol. 2. Maryland State Fire Marshal: permit 2173 FM approved. Product Line Information NOTE: 'A" suffix indicates ULC Listed model. NP-100: Adressable photoelectric detector; B21OLP base included. NP-100A: Sames as NP-100 with ULC Listing; B21OLPA base included. NP-lOOT: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B21OLPA base included. NP-i OORA: Same as NP-bOA with ULC Listing for use with a DNRA duct detector housing; B21OLPA base included. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B21OLP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. 5501 BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A 0 110 VDC inductive; 1.0 A 0 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DN-6994). ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of Fib; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with NP-1 00(A) only; box of 10. WCK-200B: White detector covers for use with NP-100(A) only; box of 10. NP-100R: Remote test capable addressable photoelectric NOTIFIER® and FireWarden® are registered trademarks of Honeywell detector for use with a DNRNDNRW duct detector housing; International Inc. B21OLP base included. @2011. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Im ®FflINI &MkMFI1IN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-6995:C • 12/07/2011 SYSTEM SENSOR 4-Wire Photoelectric Duct Smoke Detector The lnnovairFlex'° Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/sec) Versatile mounting options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 3/4-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-fan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories Agency Listings / Innova. The InnovairFiex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The lnnovairFlex housing provides ample wiring space, a 1/4-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the D4120 may be used to monitor a second sensor, D4S, simultaneously (i.e., supply and return side). As many as 50 InnovairFIex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The InnovairFiex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new lnnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. MSFM area WARNING: Duct smoke detectors are NOT a substitute for open smoke detectors; NOT a substitute for early warning detection; LISTED S911 APPROVED 3029100 approved 3242-65301 2202 NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information. InnovairFlee Duct Smoke Detector I he air duct smoke detector shall be a System Sensor lnnovairFlex' D4120 Photoelectric Duct Smoke Detector: The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector firs multiple footprints from square to rectangular.The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 20.32 meters/second).The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the SSK45 1 Multi-Signaling Accessory or the RT5451 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular Dimensions) (Square Dimensions) 1438 in (37 cm) Length; 5 in (12.74cm) Width; 7.5 in (6.36 cm) Depth 7.75 in (19.7cm) Length; gin (22.9 cm) Width; 2.5 in (635 cm) Depth Weight: 2.5 lbs (1.14 kg) Operating Temperature Range: D4120 & D4S: -4° to 158°F (-20° to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Storage Temperature Range: D4120 & D45: -22° to 158°F (-30° to 70°C); D4P120: -40° to 158°F (-40° to 70°C) Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 100 to 4000 ft/mm (0.5 to 2032 m/sec Electrical Ratings Power supply voltage: 20-29 VDC 24VAC 50-60 Hz 170 VAC 50-60 Hz Input capacitance: 270 pF max. 270 MF max. N/A Reset voltage: 3.OVDC mm. 2.OVAC mm. IOVAC mm. Reset time: (with RTS451) .03 to 03 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time: (by power down) 0.6 sec. max. 0.6 sec. max. 0.6 sec. max. Power up time: 35 sec. max. 35 sec. max. 35 sec. max. Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivitylest: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @12OVAC 60Hz Contact Ratings Alarm initiation contacts: (SPST) 2.OA @30 VDC (resistive) Alarm auxiliary contacts: (DPOT) 10A @30 VDC (resistive); 1OA @250 VAC (resistive); ½ HP @240 VAC; /4 HP @ 120 VAC Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Supervisory contacts: (SPOT) 2.OA @ 30 VDC (resistive); 2.OA @125 VAC (resistive) I wAccessory LCurrent Loads PLI VDC Device Standby Trouble Alarm APA1 51/APA4S1 12.5 mA n/a 30 mA Max. MHR/MHW 0 mA n/a 29 mA Max. RA100Z OmA n/a 12mAMax. RTS151/RTS151KEY 0mA/12mA n/a 12mAMax. RTS2/RTS2-AOS 3.0mA max 16 mA Max. with strobe: 55 mA max; without strobe 30 mA max Note: Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFIex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). A05-O4192 Wiring for 4-wire Duct Smoke Detector and Accessories I POWER INPUTS (NOTE 1) I I ?4VAcIDG 120 I I IVAC1 I I 910 I OR I I AUXILIARY CONTACTS I I FOR FAN SHUTDOWN, ETC. (NOTE 2) I AUXA AUXB I SUPERVISORY CONTACTS I (NOTE 3) UP I F —'~r ------------ I POWER INPUTS (NOTE 1) I I r -1g- 910 OR I I AUXILIARY CONTACTS I FOR FAN SHUTDOWN, ETC. (NOTE 2) I I AUXA AUXB I "it" I SUPERVISORY CONTACTS I (NOTE 3) I EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER 1 FIRST DETECTOR IN THE LOOP NOTE 1: 24V Power Inputs accept a non-polarized 24VDC or24VAC 50-60Hz. 120VAC Power Inputs accept only 120VAC 50-601-1z. Connect power source to appropriate terminals of each detector. See specifications for additional power supply information. NOTE 2: Auxiliary contacts shown in standby position. Contacts switch during alarm as indicated by arrows. Auxiliary contacts are not to be used for connection to the control panel. See specifications for contact ratings. LAST DETECTOR IN THE LOOP NOTE 3: Supervisory contacts shown in standby position. Open contacts indicate a trouble condition to the panel. See specifications for contact ratings. NOTE 4: Alarm Initiation contacts shown in standby position. Closed contacts indicate an alarm condition to the panel. See specifications for contact ratings. Please refer to the corresponding installation manual for accessory wiring diagrams. Important Notes on 2:1 Sensor-to-Power Capability 2:1 sensor-to-power capability is not available for all InnovairFIex models. The feature is only available on the D4120 4-wire conventional models. 2:1 sensor-so-power capability can be enabled using one D4120 and one D4S, or two D4S and one D4P120. ImDortant Interconnect Notes When using the interconnect feature, all interconnected units must be powered using the same independent supply. Polarity must be maintained throughout the interconnect wiring. Connect the INIT± terminal on unit 1 t the lNT-i terminal on unit 2 and so on. Similarly, connect the INT/AUX- terminal on unit ito the INT/AUX- terminal on unit 2 and so on. Up to 50 D4120 units, 50 D4P1 20 units, or 50 units of combination may be interconnected. Up to 10 DH100ACDC units may be interconnected. Please note that each of the 9 DH 100ACDC units interconnected may be replaced by three D4P1 20 units. Therefore, when using the interconnect feature a single DH 100ACDC can drive either 9 DH100ACDCs or 27 D4120 units. NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. A05.0419.002 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. rpi1 _ in RT5151 ULS40I1 RT51S1KEYULS2522 APA151 UL S4011 IL tt'• 1•1 RA100ZULS2522 MHWULS4O11 MHRULS4O11 RTS2-AOS UL 52527 AOS Information D4120 4-wire photoelectric low-flow duct smoke detector Accessories 134S 4-wire photoelectric sensor component only D4P1 20 4-wire photoelectric power board component only, 24VAC/DC, 120 VAC 2D51 4-wire conventional photoelectric sensor head DST1 Metal sampling tube duct width up to lft (03m) DSI 1.5 Metal sampling tube duct widths 1 ft to 2 ft (03 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 12 ml MHR Mini Horn, Red MHW Mini Horn, White P48-21-00 End cap for metal sampling tubes RA OOZ Remote annunciator alarm LED RIS1 51 Remote test station RTS1 51 KEY Remote test station with key lock DST5 Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) RTS2 - AOS Multi-signaling accessory DST1 0 Metal sampling tube duct widths8ftto 12ft (2.4 to 3.7 m) APA151 Remote annunciator with oiezo alarm DH400 OE-1 Weatherproof enclosure ETX Metal exhaust tube duct width lft (03m) M02-04-00 Test magnet —::-' 02 -5 y5 105yrn ,,,o TElVi 3825 Ohio Avenue. St. Charles, IL 60174 0 SENSOR' Phone: 800-5EN5OR2• Fax: 630-377-6495 AOS4I2.2/1.2305 Monitor Modules NMM.100(A), NMM.IOOP(A), ' NZM.100(A), and NDM-100(A) for FireWarden Series Panels General Four different monitor modules are available for Notifiers Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-1 00(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style.D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. NMM.100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on Fire Warden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, watertlow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style '13 (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:C NOTIFIER® by Honeywell NMM-1 00(A) (Type H) NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6999:C • 10/06/2010— Page 1 of 4 NMM-100P(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. 14150 1 I_ADDRESS I 01 13 ii II - LOOP I 10 5 43_________ 8 76 8 76 I TENS ONES /Lu The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-100P(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. NMM-100P(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). NMM-100P(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75 (6.985 cm) wide x 0.65 (1.651 cm) deep. Wire length: 6 (15.24 cm) minimum. NZM-1 00(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address:, 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-1 00(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or 0 (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 450 (11.43 cm) high x 4° (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 40 (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 4— DN-6999:C • 10/06/2010 NDM-1 00(A) Dual Monitor Module The NDM-1 00(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) IDC cir- cuits ONLY Style 0 (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 320 to 120°F (00 to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 2.125 (5.398 cm) deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-1 00(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27'. NOTE: "Ones" addresses on the NDM-100(A) are 0, 2, 4, 6, or B only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100) MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100) Product Line Information NOTE: "A" suffix indicates ULC-listed model. NMM-1 00(A): Monitor module. NMM-100P(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. DN-6999:C • 10/06/2010 - Page 3 of 4 Notifier® and Fu Warden® are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. MNEWIN 11 MIAMMIN All specifications are subject to change without notice. OUHITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6999:G • 1010612010 SYSTEM $ SENSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNAUNG APPROVED USTED 85512 FM approved except 7125-1653:0504 S4011 for ALERT models 7125-1653:0503 3057383 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync'Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 953 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VOC or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AV0S86800 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe - -- DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lK Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3. 1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 1150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.lKNon-TemooralLow 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDSB6800 L-Series Dimensions 2.47 1.37 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red I PC2WL 2-Wire, Horn Strobe, White I Ceiling Strobes SCRL Strobe, Red I SCWL Strobe, White I SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White "STEM 3825 Ohio Avenue • St. Charles, IL 60174 02017 System Sensor. Product specifications subject to change wthout notice. Visit syeternsenuor.corrl for cinrent product information. including the latest version of this data sheet SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 AV0586801•03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0235 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models Fire Warden 100 andiFire Warden 100-2laddressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). This panel also can be used with NFV-25/50ZST (Fire Voice-25/-50ZST) Zoned System Voice with Telephone for Emergency Voice evacuation Applications. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Fire Warden 100-2 panel also suitable for high-rise application for use with Model NFC-50/100 emergency voice evacuation panel (CSFM #6911-0028:0265). This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:0208 *Rev. 11-15-I3GT ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1157:0136 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Brad Tucker (417) 831-9362 Fax (417) 831-1325 Email: btucker@dmp.com DESIGN: Models CellComSLC, CellComSLCZ,l*CellComSLCFJ* iComSLF, iCOMSL and iComSLZ Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. RATING: 12 VDC or 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and ETL label. APPROVAL: Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. *Rev. 07-14-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:0209 Page 1 of I CATEGORY: 7120 --ANNUNCIATORS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeyweIl.com DESIGN: ModelslFpU-80hnd *FDU80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. NOTE: *Rev. 10-03-06jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing "should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NBG-12, NBG-125, NBG-12LR, NBG-12LRA, NBG-I2LAO, NBG-12LA0B, NBC-12-LO, NBC-i 2LOB, NBG-i 2W, NBC-i 2LW, NBC-i 2NC, NBC-i 2WP, NBG-i 2LWP, NBC-12L, NBG-i 2LX, NBG-1 2LA, NBC-12P5, NBC-i 2LSP, NBC-i 2LPS, NBC-I 2LPSP, NBC-12SP,INOT-BGi2LXJ NBC-12LXSP, NBC-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBC-i 2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBC-12LW, NBC-12W, NBC-12LWP, NBG-12LAO, NBG-12LO, NBC-i 2LAOB and NBC-i 2LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-1 0 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist *Correed 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0231 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models i NP-i 001 NP-1 OOR* and NP-1 OOT photoelectric type smoke detectors. Model NP-lOOT has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0- 4000 FPM. *Models NP-100 and NP-IOOR are also approved for installations inside Notifier duct detector housing ND-200 (OSFM Listing No. 3242-0028:236) and System Sensor duct detector housing DNRW (OSFM Listing No. 3242-1653:210). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0075:0194 *Rev. 01-27-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 10 Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1653:0207 Page 1 of I CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: ModelslD4l2oj D4240, RD4120, P270-3000PL, TD41203, TD41204, LD4S, LD412OX, LD4I20H, D4S, D4P120, CD4PI20 LD4P120X, LD4PI20H, TD4C, PD4120, YD4120, YD4PI20, and AD4PI20 four-wire conventional photoelectric duct smoke detectors and subassemblies. Unit consists of a duct detector housing, powerboard with electrical components and relays, exhaust tubes, and listed 21351 detector head (CSFM Listing No. 7272-1653:203). Model AD4S sensor component. Models *TD4c LD4120X, LD4120H, LD4P120X and LD4P120H do not contain a 120 VAC transformer. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20-29 VDC, *24 VAC, 120 VAC (except Models *TD4C LD4120X, LD4I20H, LD4P120X and LD4P120H *do not have 120 VAC rating). INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-27-13 gt A This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models lRTS151,1R1S151 KEY and RAIOOZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not NO an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 9 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: ModelslNMM-IOOPI NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM..100..6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185 08-23-11 rev. mt 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the. item listed. This listing should not be used to verify correct Mv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0237 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeyweII.com DESIGN: Model dual monitor module. Intended to be installed in a standard 4" square junction box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a control unit accessory for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1209:198 XLF: 7300-1653:0141 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct rev operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAViD CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: System Sensor Indoor 2-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP and P2WL-SP Wall Horn Strobes; PC2RL and IPC2WLICeiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WailTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: 02-14-17 gt 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I ml At operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20 KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL,lSCWLland SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt 0• This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed !J\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division