Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6800 AVENIDA ENCINAS; ; FPC2017-0377
city of Carlsbad Print Date: 09/28/2023 Permit No: FPC2017-0377 Job Address: 6800 AVENIDA ENCINAS, CARLSBAD, CA 92011-3201 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2144501600 Track fl: Valuation: $5,943,412.96 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Fire Sprinklers Applied: 12/20/2017 Issued: 01/10/2018 DEV2017-0015 Fina!ed Close Out: 03/18/2021 Final Inspection: INSPECTOR: Wang, Cindy Fieri, Dominic Project Title: HOEHN PORSCHE Description: HOEHN PORSCHE -SPRINKLER >100 (1200 HEADS) Applicant: FPContractor: PARAMOUNT FIRE SYSTEMS INC PARAMOUNT FIRE SYSTEMS INC JAMES CHENEY P0 BOX 713194 8069 WING AVE SANTEE, CA 92072-3194 EL CAJON, CA 92020-1245 (619) 562-6247 (619) 562-6247 FEE AMOUNT FIRE NFPA 13 System> 100 heads (includes 1 riser) $832.00 FIRE NFPA 13 System> 100 heads (includes 1 riser) $230.00 FIRE NFPA 13 System> 100 heads (includes 1 riser) $230.00 Total Fees: $1,292.00 Total Payments To Date: $1,292.00 Balance Due: $0.00 Fire Department . Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov CI I A Kiriamo wi FIRE S VS TEMS, INC.AIL HOEHN PORSCHE CARLSBAD 6800 Avenida Encinas Carlsbad, CA AUTOMATIC WET FIRE SPRINKLER SYSTEM Calculation Submittal Table of Contents Remote Area Standpipe: Remote Area IA, L Parts Storage: Remote Area IB, Li Oil Room: Remote Area L2A, L2 Parts Storage: Remote Area L213, L2 Auto Service: Remote Area L3A, L3 Parking: Remote Area L313, L3 Parking: Standpipe Proof, 750 GPM Design Density .30/1400 Design Density.25/3000 Design Density.30/2293 Design Density .20/1500 Design Density. 15/1500 Design Density. 15/1500 Flow Test Data Backflow Data P.O. Box 713194 Santee, CA 92072 (619) 562-6247 fax (619) 562-6273 ... Fire Protection by Computer Design PARAMOUNT FIRE SYSTEMS, INC C-16 788204 Job Name : HOEHN Standpipe Calculation Building : 4 STORY DEALERSHIP Location : 6800 AVENIDA ENCINAS CARLSBAD System : STANDPIPE Contract Data File : HOEHN Level 1 standpipe.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PARAMOUNT FIRE SYSTEMS, INC Page HOEHN Standpipe Calculation Date HYDRAULIC DESIGN INFORMATION SHEET Name - HOEHN PORSCHE Date - 8-17 Location - 6800 AVENIDA ENCINAS CARLSBAD Building - 4 STORY DEALERSHIP System No. - STANDPIPE Contractor - PARAMOUNT FIRE SYSTEMS IN Contract No. - Calculated By - Drawing No. - FP-1 THRU 3 Occupancy - MULTIPLE S (XX)NFPA 14 Number of Standpipes Y ( )Other S ( )Specific Ruling T ( )1 Made (XX)2 ( )3 by ( )4 Date E Flow at Top Most Outlet - 500 Gpm System Type N Pres. at Top Most Outlet - 100 Psi (XX) Wet ( ) Dry Flow For Ea. Additional Standpipe - 250 Gpm D Total Additional Flow - 750 Gpm E Elevation at Highest Outlet - 37.5' Feet S Hose Valve Connection ( )l 1/2" (X)2 1/2" I Class Service (X)I ( )II ( )III G Note: N Calculation Gpm Required 750 Psi Required 164.67 At FDC Summary C-Factor Used: Overhead 120 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 6-23-17 Cap. T Time of Test - COMPUTER Rated Cap. Elev. E Static (Psi) - 112 @ Psi R Residual (Psi) - 85 Elev. Well Flow (Gpm) - 6425 Proof Flow Gpm S Elevation - 60' U P Location: AT HYDRANT AT SITE P L Source of Information: HYDRAULIC ANALYSIS BY JENNIFER MAEL PE Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C PARAMOUNT FIRE SYSTEMS, INC Page 2 HOEHN Standpipe Calculation Date City Water Supply: Demand: CI - Static Pressure : 175 Dl - Elevation : 17.670 C2 - Residual Pressure: 150 D2 - System Flow : 250 C2 - Residual Flow : 1500 D2 - System Pressure :164.671 Hose ( Demand) : 500 D3 - System Demand : 750 Safety Margin : 3.394 180 •.G4-. 168 - D3 2 C P 144 -_ R 132 E120 S 108 s 96 U84 R72 E60 48 36 24 -- 12 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PARAMOUNT FIRE SYSTEMS, INC Page 3 HOEHN Standpipe Calculation Date Fitting Legend Abbrev. Name /2 % 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90'Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 I- Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD PARAMOUNT FIRE SYSTEMS, INC Page 4 HOEHN Standpipe Calculation Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. HV1 37.5 25 100.0 na 250.0 HV2 37.5 100.0 na 250.0 SP2R 37.5 102.69 na SP2I 10.0 118.31 na SJ 9.17 135.27 na TOR 9.17 152.28 na BOR 2.0 157.28 na UG1 2.0 158.34 na FDC -3.3 164.67 na HV3 32.5 120.55 na 250.0 SP3R 32.5 123.24 na SP31 9.17 134.06 na 0.1 250 100.0 The maximum velocity is 16.75 and it occurs in the pipe between nodes HVI and SP2R Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 5 HOEHN Standpipe Calculation Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn HVI 250.00 2.469 1 12.0 0.500 100.000 K Factor = 25.00 to 120.0 0.0 12.000 0.0 SP2R 250.0 0.2154 0.0 12.500 2.693 Vel = 16.75 0.0 250.00 102.693 K Factor= 24.67 HV2 250.00 2.469 T 12.0 0.500 100.000 Qa = 250 to 120.0 0.0 12.000 0.0 SP2R 250.0 0.2154 0.0 12.500 2.693 Vel = 16.75 SP2R 250.00 4.31 3E 41.811 30.125 102.693 to 120.0 0.0 41.811 11.910 SP21 500.0 0.0515 0.0 71.936 3.705 Vel= 11.00 SP21 0.0 4.31 4E 55.748 222.000 118.308 to 120.0 B 16.724 100.346 0.359 Si 500.0 0.0515 T 27.874 322.346 16.603 Vel= 11.00 SJ 250.00 4.31 F 5.575 51.500 135.270 to 120.0 I 9.756 104.528 0.0 TOR 750.0 0.1090 4J 89.197 156.028 17.014 Vel = 16.49 TOR 0.0 6.357 E 17.603 7.170 152.284 to 120.0 T 37.72 108.131 3.105 BOR 750.0 0.0164 B 12.573 115.301 1.895 Vel = 7.58 S 40.235 BOR 0.0 6.357 E 17.603 9.000 157.284 to 120.0 T 37.72 55.323 0.0 UG1 750.0 0.0164 0.0 64.323 1.057 Vel = 7.58 UG1 0.0 6.09 7E 151.081 150.000 158.341 to 150.0 0.0 151.080 2.295 FDC 750.0 0.0134 0.0 301.080 4.035 Vel = 8.26 0.0 750.00 164.671 KFactor= 58.45 HV3 250.00 2.469 1 12.0 0.500 120.552 Qa = 250 to 120.0 0.0 12.000 0.0 SP3R 250.0 0.2154 0.0 12.500 2.693 Vel = 16.75 SP3R 0.0 4.31 1 27.874 22.100 123.245 to 120.0 0.0 27.874 10.104 SP31 250.0 0.0143 0.0 49.974 0.714 Vel = 5.50 SP31 0.0 4.31 2E 27.874 12.000 134.063 to 120.0 B 16.724 72.472 0.0 Si 250.0 0.0143 1 27.874 84.472 1.207 Vel = 5.50 0.0 250.00 135.270 KFactor= 21.50 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - Fire Protection by Computer Design PARAMOUNT FIRE SYSTEMS, INC C-16 788204 Job Name : HOEHN Level 1 Parts Storage Building : LEVEL I Location : 6800 AVENIDA ENCINAS System : LI-I Contract Data File : HOEHN Level I Area 1.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PARAMOUNT FIRE SYSTEMS, INC Page HOEHN Level 1 Parts Storage Date HYDRAULIC CALCULATIONS for Project name: HOEHN PORSCHE Location: 6800 AVENIDA ENCINAS Drawing no: LEVEL 1 Date: 8-17 Design Remote area number: LI-I Remote area location: LEVEL I PARTS STORAGE Occupancy classification: STORAGE DENSITY / AUTO SERVICE Density: .30 /.20 - Gpm/SqFt Area of application: 2500 - SqFt Coverage per sprinkler: 100- SqFt Type of sprinklers calculated: 11.2K! 5.6K No. of sprinklers calculated: 32 In-rack demand: NA - GPM Hose streams: 500 - GPM Total water required (including hose streams): 1605.3 -GPM @ 89.2 - Psi Type of system: WET LOOP / TREE Volume of dry orpreaction system: NA - Gal Water supply information Date: 6-23-17 Location: 12" MAIN @ 6800 AVENIDA ENCINAS Source: CEO WATER AVAILABILITY FORM Name of contractor: PARAMOUNT FIRE SYSTEMS INC Address: 8069 WING AVENUE EL CAJON, CA Phone number: 619 562-6247 Name of designer: JAMES CHENEY Authority having jurisdiction: CARLSBAD FIRE PREVENTION BUREAU Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C PARAMOUNT FIRE SYSTEMS, INC Page 2 HOEHN Level I Parts Storage Date City Water Supply: Demand: Cl - Static Pressure : 100.8 Dl - Elevation : 5.760 C2 - Residual Pressure: 76.5 D2 - System Flow :1105.31 C2 - Residual Flow : 6425 D2 - System Pressure : 89.223 Hose (Demand) : 500 D3 - System Demand :1605.31 Safety Margin : 9.710 150 140 130 p120 F' 110 100 )2 C2 80 - - U70 R 60 E5° 40 30 Vol., 20 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PARAMOUNT FIRE SYSTEMS, INC Page 3 HOEHN Level I Parts Storage Date Fitting Legend Abbrev. Name 'A % 1 1% 1'/2 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13ButterfIyValve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD PARAMOUNT FIRE SYSTEMS, INC Page 4 HOEHN Level 1 Parts Storage Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 10.83 11.2 10.39 na 36.1 0.3 100 7.17 2 10.83 11.2 10.48 na 36.27 0.3 100 7.17 3 10.83 11.2 10.83 na 36.85 0.3 100 7.17 4 10.83 12.73 na 5 10.83 11.2 14.9 na 43.23 0.3 100 7.17 6 10.83 11.2 16.25 na 45.15 0.3 100 7.17 7 10.83 11.2 18.43 na 48.09 0.3 100 7.17 9 9.17 25.22 na 10 9.17 25.38 na 11 9.17 25.58 na 12 9.17 26.06 na 13 9.17 26.84 na 14 9.17 49.72 na JA 9.17 51.56 na TOR 9.17 53.92 na BOR 2.0 60.91 na UG1 2.0 63.07 na UG2 0.0 72.21 na UG3 0.0 81.34 na HYD 0.0 83.68 na 500.0 TEST -3.3 89.22 na 17 10.83 11.2 13.22 na 40.73 0.3 100 7.17 18 10.83 11.2 13.34 na 40.91 0.3 100 7.17 19 10.83 11.2 16.69 na 45.75 0.3 100 7.17 20 10.83 11.2 17.66 na 47.06 0.3 100 7.17 21 10.83 11.2 19.39 na 49.32 0.3 100 7.17 23 9.17 25.22 na 24 10.0 11.2 16.01 na 44.82 0.3 100 7.17 27 10.83 18.97 na 28 10.83 19.62 na 29 10.83 21.18 na 31 10.0 11.2 16.57 na 45.58 0.3 100 7.17 32 10.0 11.2 16.35 na 45.29 0.3 100 7.17 33 10.83 19.37 na 34 10.83 20.04 na 35 10.83 21.62 na 37 10.0 11.2 16.91 na 46.06 0.3 100 7.17 38 10.0 11.2 17.88 na 47.35 0.3 100 7.17 39 10.0 11.2 18.24 na 47.83 0.3 100 7.17 SP1 10.0 5.6 20.08 na 25.09 0.1 150 7.0 SI 10.83 21.0 na 40 10.0 11.2 18.03 na 47.56 0.3 100 7.17 41 10.83 21.37 na 43 9.17 25.76 na 44 9.17 25.98 na 45 9.17 26.0 na 48 9.17 50.33 na 49 9.17 50.35 na 50 9.17 50.41 na S2 10.0 5.6 14.66 na 21.45 0.2 100 7.0 S3 10.0 5.6 14.85 na 21.58 0.2 100 7.0 S4 10.0 5.6 - 15.69 na 22.18 0.2 100 7.0 S5 10.0 5.6 14.7 na 21.47 0.2 100 7.0 S6 10.0 5.6 14.88 na 21.6 0.2 100 7.0 S7 10.0 5.6 15.72 na 22.21 0.2 100 7.0 S8 10.0 5.6 10.33 na 18.0 0.2 90 7.0 S9 10.0 5.6 10.48 na 18.13 0.2 90 7.0 S10 10.0 5.6 11.03 na 18.6 0.2 90 7.0 S11 10.0 5.6 14.8 na 21.54 0.2 90 7.0 S12 10.0 5.6 16.97 na 23.07 0.2 90 7.0 S13 10.0 5.6 24.5 na 27.72 0.2 90 7.0 Computer Programs by Hydratec Inc. Route 111 Wndham N.H. USA 03087 Flow Summary - Standard PARAMOUNT FIRE SYSTEMS, INC Page 5 HOEHN Level 1 Parts Storage Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. M2 10.0 26.3 na S14 10.0 5.6 26.29 na 28.72 0.2 90 7.0 The maximum velocity is 22 and it occurs in the pipe between nodes S13 and M2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 6 HOEHN Level 1 Parts Storage Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 36.10 2.203 0.0 9.000 10.391 KFactor= 11.20 to 120.0 0.0 0.0 0.0 2 36.1 0.0104 0.0 9.000 0.094 Vel = 3.04 2 36.27 2.203 0.0 9.000 10.485 KFactor= 11.20 to 120.0 0.0 0.0 0.0 3 72.37 0.0379 0.0 9.000 0.341 Vel = 6.09 3 36.85 2.203 2E 13.639 9.833 10.826 K Factor = 11.20 to 120.0 0.0 13.639 0.0 4 109.22 0.0811 0.0 23.472 1.903 VeI= 9.19 4 0.0 2.203 3E 20.458 6.250 12.729 to 120.0 0.0 20.458 0.0 5 109.22 0.0811 0.0 26.708 2.166 VeI= 9.19 5 43.22 2.203 0.0 9.000 14.895 K Factor = 11.20 to 120.0 0.0 0.0 0.0 6 152.44 0.1503 0.0 9.000 1.353 Vel = 12.83 6 45.15 2.203 0.0 9.000 16.248 KFactor= 11.20 to 120.0 0.0 0.0 0.0 7 197.59 0.2429 0.0 9.000 2.186 Vel = 16.63 7 48.09 2.203 T 13.639 3.050 18.434 KFactor= 11.20 to 120.0 0.0 13.639 0.719 9 245.68 0.3634 0.0 16.689 6.064 Vel = 20.68 9 22.55 4.31 0.0 10.020 25.217 to 120.0 0.0 0.0 0.0 10 268.23 0.0163 0.0 10.020 0.163 Vel = 5.90 10 72.65 4.31 0.0 8.010 25.380 to 120.0 0.0 0.0 0.0 11 340.88 0.0253 0.0 8.010 0.203 Vel= 7.50 11 202.97 4.31 0.0 8.000 25.583 to 120.0 0.0 0.0 0.0 12 543.85 0.0601 0.0 8.000 0.481 Vel = 11.96 12 204.46 4.31 0.0 7.180 26.064 to 120.0 0.0 0.0 0.0 13 748.31 0.1086 0.0 7.180 0.780 Vel = 16.46 13 155.77 4.31 E 13.937 106.660 26.844 to 120.0 T 27.874 41.811 0.0 14 904.08 0.1541 0.0 148.471 22.876 Vel = 19.88 14 0.0 6.357 T 37.72 41.330 49.720 to 120.0 0.0 37.720 0.0 JA 904.08 0.0232 0.0 79.050 1.835 VeI= 9.14 JA 201.23 6.357 E 17.603 43.750 51.555 to 120.0 F 8.801 26.404 0.0 TOR 1105.31 0.0337 0.0 70.154 2.362 Vel = 11.17 TOR 0.0 6.357 E 17.603 7.170 53.917 to 120.0 T 37.72 108.131 3.105 BOR 1105.31 0.0337 B 12.573 115.301 3.883 Vel= 11.17 S 40.235 BOR 0.0 6.357 E 17.603 9.000 60.905 to 120.0 1 37.72 55.323 0.0 UG1 1105.31 0.0337 0.0 64.323 2.166 Vel= 11.17 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 7 HOEHN Level I Parts Storage Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG1 0.0 6.09 7E 151.081 150.000 63.071 to 150.0 0.0 151.080 0.866 UG2 1105.31 0.0275 0.0 301.080 8.268 Vel = 12.17 UG2 0.0 6.09 0.0 5.000 72.205 to 150.0 0.0 0.0 9.000 * * Fixed Loss = 9 UG3 1105.31 0.0276 0.0 5.000 0.138 Vel = 12.17 UG3 0.0 6.16 E 20.084 16.000 81.343 to 140.0 T 43.037 63.121 0.0 HYD 1105.31 0.0295 0.0 79.121 2.335 Vel = 11.90 HYD 500.00 6.16 E 20.084 2.500 83.678 Qa = 500 to 140.0 G 4.304 67.425 1.429 TEST 1605.31 0.0589 T 43.037 69.925 4.116 Vel= 17.28 0.0 1605.31 89.223 K Factor = 169.95 17 40.73 2.203 0.0 9.000 13.222 K Factor = 11.20 to 120.0 0.0 0.0 0.0 18 40.73 0.0131 0.0 9.000 0.118 Vel= 3.43 18 40.90 2.203 6E 40.916 29.830 13.340 KFactor= 11.20 to 120.0 0.0 40.916 0.0 19 81.63 0.0473 0.0 70.746 3.348 Vel = 6.87 19 45.75 2.203 0.0 9.000 16.688 KFactor= 11.20 to 120.0 0.0 0.0 0.0 20 127.38 0.1078 0.0 9.000 0.970 Vel = 10.72 20 47.07 2.203 0.0 9.000 17.658 K Factor = 11.20 to 120.0 0.0 0.0 0.0 21 174.45 0.1929 0.0 9.000 1.736 Vel = 14.68 21 49.32 2.203 T 13.639 3.050 19.394 K Factor = 11.20 to 120.0 0.0 13.639 0.719 23 223.77 0.3057 0.0 16.689 5.102 Vel = 18.83 23 -201.22 4.31 0.0 10.750 25.215 to 120.0 0.0 0.0 0.0 9 22.55 0.0002 0.0 10.750 0.002 Vet = 0.50 0.0 22.55 25.217 KFactor= 4.49 24 44.82 1.08 T 5.762 0.830 16.013 KFactor= 11.20 to 120.0 0.0 5.762 -0.359 27 44.82 0.5024 0.0 6.592 3.312 Vel = 15.70 27 65.20 2.203 0.0 8.000 18.966 to 120.0 0.0 0.0 0.0 28 110.02 0.0821 0.0 8.000 0.657 VeI= 9.26 28 45.59 2.203 0.0 10.000 19.623 to 120.0 0.0 0.0 0.0 29 155.61 0.1561 0.0 10.000 1.561 VeI= 13.10 29 47.35 2.203 T 13.639 0.780 21.184 to 120.0 0.0 13.639 0.719 11 202.96 0.2552 0.0 14.419 3.680 Vet = 17.08 0.0 202.96 25.583 KFactor= 40.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 8 HOEHN Level I Parts Storage Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 31 45.58 1.08 T 5.762 0.830 16.565 KFactor= 11.20 to 120.0 0.0 5.762 -0.359 28 45.58 0.5184 0.0 6.592 3.417 Vel = 15.96 0.0 45.58 19.623 KFactor= 10.29 32 45.29 1.08 T 5.762 0.830 16.354 K Factor = 11.20 to 120.0 0.0 5.762 -0.359 33 45.29 0.5121 0.0 6.592 3.376 Vel = 15.86 33 65.28 2.203 0.0 8.000 19.371 to 120.0 0.0 0.0 0.0 34 110.57 0.0830 0.0 8.000 0.664 VeI= 9.31 34 46.06 2.203 0.0 10.000 20.035 to 120.0 0.0 0.0 0.0 35 156.63 0.1580 0.0 10.000 1.580 Vel = 13.18 35 47.83 2.203 T 13.639 0.780 21.615 to 120.0 0.0 13.639 0.719 12 204.46 0.2587 0.0 14.419 3.730 Vel = 17.21 0.0 204.46 26.064 K Factor= 40.05 37 46.06 1.08 T 5.762 0.830 16.911 K Factor= 11.20 to 120.0 0.0 5.762 -0.359 34 46.06 0.5284 0.0 6.592 3.483 Vel = 16.13 0.0 46.06 20.035 K Factor= 10.29 38 47.35 1.08 T 5.762 0.830 17.877 K Factor= 11.20 to 120.0 0.0 5.762 -0.359 29 47.35 0.5561 0.0 6.592 3.666 Vel = 16.58 0.0 47.35 21.184 KFactor= 10.29 39 47.83 1.08 T 5.762 0.830 18.239 K Factor = 11.20 to 120.0 0.0 5.762 -0.359 35 47.83 0.5666 0.0 6.592 3.735 Vel = 16.75 0.0 47.83 21.615 KFactor= 10.29 SPI 25.09 1.08 2E 4.61 2.833 20.081 K Factor =5.60 to 120.0 0.0 4.610 -0.359 Si 25.09 0.1717 0.0 7.443 1.278 Vel = 8.79 SI 0.0 1.536 0.0 12.000 21.000 to 120.0 0.0 0.0 0.0 41 25.09 0.0310 0.0 12.000 0.372 Vel = 4.34 0.0 25.09 21.372 KFactor= 5.43 40 47.56 1.08 T 5.762 0.830 18.034 KFactor= 11.20 to 120.0 0.0 5.762 -0.359 41 47.56 0.5608 0.0 6.592 3.697 Vel = 16.66 41 25.10 1.536 T 10.108 4.780 21.372 to 120.0 0.0 10.108 0.719 10 72.66 0.2209 0.0 14.888 3.289 Vel = 12.58 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 9 HOEHN Level 1 Parts Storage Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 72.66 25.380 K Factor= 14.42 23 201.22 4.31 3E 41.811 15.100 25.215 to 120.0 0.0 41.811 0.0 43 201.22 0.0096 0.0 56.911 0.544 Vel = 4.42 43 -64.78 4.31 2E 27.874 19.666 25.759 to 120.0 0.0 27.874 0.0 44 136.44 0.0047 0.0 47.540 0.222 Vel = 3.00 44 -68.25 4.31 0.0 13.166 25.981 to 120.0 0.0 0.0 0.0 45 68.19 0.0013 0.0 13.166 0.017 Vel = 1.50 45 0.0 1.536 2E 10.108 93.500 25.998 to 120.0 2T 20.216 30.324 0.0 48 68.19 0.1965 0.0 123.824 24.331 Vel = 11.81 48 0.0 4.31 0.0 13.000 50.329 to 120.0 0.0 0.0 0.0 49 68.19 0.0013 0.0 13.000 0.017 VeI= 1.50 49 68.25 4.31 0.0 13.375 50.346 to 120.0 0.0 0.0 0.0 50 136.44 0.0046 0.0 13.375 0.062 Vel = 3.00 50 64.78 4.31 4E 55.748 36.330 50.408 to 120.0 1 27.874 83.622 0.0 JA 201.22 0.0096 0.0 119.952 1.147 VeI= 4.42 0.0 201.22 51.555 KFactor= 28.02 43 64.78 1.536 2E 10.108 97.500 25.759 to 120.0 31 30.324 40.432 0.0 50 64.78 0.1787 0.0 137.932 24.649 Vel = 11.22 0.0 64.78 50.408 K Factor= 9.12 44 68.25 1.536 2E 10.108 93.500 25.981 to 120.0 21 20.216 30.324 0.0 49 68.25 0.1968 0.0 123.824 24.365 Vel = 11.82 0.0 68.25 50.346 K Factor= 9.62 S2 21.45 1.536 0.0 8.000 14.665 K Factor =5.60 to 120.0 0.0 0.0 0.0 S3 21.45 0.0231 0.0 8.000 0.185 Vel = 3.71 S3 21.58 1.536 0.0 10.000 14.850 K Factor =5.60 to 120.0 0.0 0.0 0.0 S4 43.03 0.0838 0.0 10.000 0.838 Vel = 7.45 S4 22.18 1.536 1 10.108 10.000 15.688 K Factor =5.60 to 120.0 0.0 10.108 -0.359 27 65.21 0.1809 0.0 20.108 3.637 Vel = 11.29 0.0 65.21 18.966 KFactor= 14.97 S5 21.47 1.536 0.0 8.000 14.698 K Factor =5.60 to 120.0 0.0 0.0 0.0 S6 21.47 0.0232 0.0 8.000 0.186 VeI= 3.72 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 10 HOEHN Level I Parts Storage Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S6 21.60 1.536 0.0 10.000 14.884 K Factor =5.60 to 120.0 0.0 0.0 0.0 S7 43.07 0.0840 0.0 10.000 0.840 Vel = 7.46 S7 22.21 1.536 2E 10.108 12.000 15.724 K Factor =5.60 to 120.0 0.0 10.108 -0.359 33 65.28 0.1812 0.0 22.108 4.006 VeI= 11.30 0.0 65.28 19.371 KFactor= 14.83 S8 18.00 1.536 0.0 9.000 10.332 K Factor =5.60 to 120.0 0.0 0.0 0.0 S9 18.0 0.0167 0.0 9.000 0.150 Vel = 3.12 S9 18.13 1.536 0.0 9.000 10.482 K Factor =5.60 to 120.0 0.0 0.0 0.0 S10 36.13 0.0607 0.0 9.000 0.546 Vel = 6.26 SIO 18.60 1.536 4E 20.216 8.600 11.028 K Factor =5.60 to 120.0 0.0 20.216 0.0 SI1 54.73 0.1308 0.0 28.816 3.769 Vel= 9.48 Sill 21.54 1.536 0.0 9.000 14.797 K Factor =5.60 to 120.0 0.0 0.0 0.0 S12 76.27 0.2418 0.0 9.000 2.176 Vel = 13.21 S12 23.07 1.536 T 10.108 9.000 16.973 K Factor =5.60 to 120.0 0.0 10.108 0.0 S13 99.34 0.3941 0.0 19.108 7.530 Vel = 17.20 S13 27.72 1.536 0.0 2.900 24.503 K Factor 5.60 to 120.0 0.0 0.0 0.0 M2 127.06 0.6214 0.0 2.900 1.802 VeI= 22.00 M2 28.72 4.31 T 27.874 2.292 26.305 to 120.0 0.0 27.874 0.359 13 155.78 0.0060 0.0 30.166 0.180 Vel = 3.43 0.0 155.78 26.844 KFactor= 30.07 S14 28.72 4.31 T 27.874 2.292 26.294 K Factor = 5.60 to 120.0 0.0 27.874 4.331 Ml 28.72 0.0003 0.0 30.166 0.008 Vel = 0.63 0.0 28.72 30.633 K Factor= 5.19 M2 -28.72 4.31 0.0 10.000 26.305 to 120.0 0.0 0.0 4.331 Ml -28.72 -0.0003 0.0 10.000 -0.003 Vel = 0.63 0.0 -28.72 30.633 K Factor= -5.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - Fire Protection by Computer Design PARAMOUNT FIRE SYSTEMS, INC C-16 788204 Job Name : HOEHN OIL ROOM CALC Building : LEVEL I Location : 6800 AVENIDA ENCINAS System : 1-I-2 Contract Data File : HOEHN LEVEL 1-2 OIL ROOM.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PARAMOUNT FIRE SYSTEMS, INC Page HOEHN OIL ROOM CALC Date HYDRAULIC CALCULATIONS for Project name: HOEHN PORSCHE Location: 6800 AVENIDA ENCINAS Drawing no: LEVEL I Date: 8-17 Design Remote area number: 1-I-2 Remote area location: LEVEL I OIL ROOM AND ADJACENT SERVICE AREA Occupancy classification: .25 OIL ROOM /.20 SERVICE AREA Density: .25 /.20 - Gpm/SqFt Area of application: 3000 - SqFt Coverage per sprinkler: 90/130- SqFt Type of sprinklers calculated: 8.0 K / 5.6K No. of sprinklers calculated: 32 In-rack demand: NA - GPM Hose streams: 500 - GPM Total water required (including hose streams): 1676.7-GPM @ 85.4 - Psi Type of system: WET LOOP / TREE Volume of dry or preaction system: NA - Gal Water supply information Date: 6-23-17 Location: 12" MAIN @ 6800 AVENIDA ENCINAS Source: CFD WATER AVAILABILITY FORM Name of contractor: PARAMOUNT FIRE SYSTEMS INC Address: 8069 WING AVENUE EL CAJON, CA Phone number: 619 562-6247 Name of designer: JAMES CHENEY Authority having jurisdiction: CARLSBAD FIRE PREVENTION BUREAU Notes: (Include peaking information or gridded systems here.) .25 DENSITY FOR CLASS Ill-B LIQUIDS IN OIL ROOM .20 DENSITY FOR AUTO SERVICE AREAS ORDINARY 2 HAZARD Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C PARAMOUNT FIRE SYSTEMS, INC Page 2 HOEHN OIL ROOM CALC Date City Water Supply: Demand: Cl - Static Pressure : 100.8 Dl - Elevation : 6.120 C2 - Residual Pressure: 76.5 D2 - System Flow :1176.59 C2 - Residual Flow : 6425 02 - System Pressure : 85.388 Hose (Demand) : 500 D3 - System Demand :1676.59 Safety Margin : 13.388 150 140 130 p120 R11° E 100 S 90 - D2 -_... 80 - 3 C2 u 70 R6° E5° 40 30 20 • ----I 10 I ________________________ 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PARAMOUNT FIRE SYSTEMS, INC HOEHN OIL ROOM CALC Page 3 Date Fitting Legend Abbrev. Name /2 % 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD PARAMOUNT FIRE SYSTEMS, INC Page 4 HOEHN OIL ROOM CALC Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 10.83 5.6 21.85 na 26.18 0.2 130 7.0 2 10.83 5.6 22.23 na 26.4 0.2 130 7.0 3 10.83 25.85 na 4 10.83 26.45 na M04 9.17 42.65 na M05 9.17 42.91 na JA 9.17 43.03 na M06 9.17 43.9 na M07 9.17 44.88 na M08 9.17 45.98 na M09 9.17 46.58 na M10 9.17 46.89 na TOR 9.17 47.68 na BOR 2.0 55.14 na UGI 2.0 57.58 na UG2 0.0 67.72 na UG3 0.0 76.88 na HYD 0.0 79.5 na 500.0 TEST -3.3 85.39 na 114 10.83 5.6 24.0 na 27.44 0.2 130 7.0 15 10.83 5.6 25.48 na 28.27 0.2 130 7.0 16 10.83 26.15 na 19 10.83 5.6 28.71 na 30.0 0.2 130 7.0 20 10.83 5.6 29.49 na 30.41 0.2 130 7.0 22 10.83 5.6 30.47 na 30.91 0.2 130 7.0 23 10.83 5.6 31.16 na 31.26 0.2 130 7.0 21 10.83 33.41 na MO1 9.17 41.5 na M02 9.17 41.51 na M03 9.17 41.61 na 27 10.83 5.6 28.72 na 30.01 0.2 130 7.0 28 10.83 5.6 29.51 na 30.42 0.2 130 7.0 30 10.83 5.6 30.48 na 30.92 0.2 130 7.0 31 10.83 5.6 31.18 na 31.27 0.2 130 7.0 29 10.83 33.43 na 32 10.83 5.6 28.79 na 30.05 0.2 130 7.0 33 10.83 5.6 29.58 na 30.46 0.2 130 7.0 35 10.83 5.6 30.55 na 30.95 0.2 130 7.0 36 10.83 5.6 31.25 na 31.31 0.2 130 7.0 34 10.83 33.51 na 37 10.83 5.6 21.56 na 26.0 0.2 130 7.0 337 10.83 5.6 21.92 na 26.22 0.2 130 7.0 38 10.83 5.6 24.16 na 27.53 0.2 130 7.0 39 10.83 38.19 na 40 10.83 38.24 na 41 10.83 5.6 31.65 na 31.51 0.2 130 7.0 42 10.83 5.6 32.3 na 31.83 0.2 130 7.0 43 10.83 5.6 34.66 na 32.97 0.2 130 7.0 45 10.83 5.6 32.62 na 31.98 0.2 130 7.0 46 10.83 33.46 na 47 10.83 5.6 32.76 na 32.05 0.2 130 7.0 48 10.83 5.6 33.94 na 32.62 0.2 130 7.0 49 10.83 5.6 34.63 na 32.95 0.2 130 7.0 50 10.83 5.6 37.14 na 34.13 0.2 130 7.0 M51 10.83 42.17 na M52 10.92 42.11 na M53 10.92 42.11 na M54 10.92 42.11 na M55 10.92 40.83 na M56 10.92 40.83 na M57 9.33 41.51 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard PARAMOUNT FIRE SYSTEMS, INC Page 5 HOEHN OIL ROOM CALC Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. M59 9.17 41.53 na 60 10.83 8 35.73 na 47.82 0.25 90 7.0 61 10.83 42.41 na 63 10.83 8 36.97 na 48.64 0.25 90 7.0 64 10.83 42.4 na 65 10.83 5.6 39.17 na 35.05 0.2 130 7.0 67 10.83 5.6 39.7 na 35.29 0.2 130 7.0 66 10.83 40.55 na 68 10.83 5.6 39.69 na 35.28 0.2 130 7.0 70 10.83 5.6 40.13 na 35.48 0.2 130 7.0 69 10.83 41.07 na 71 10.83 5.6 41.09 na 35.9 0.2 130 7.0 73 10.83 5.6 41.25 na 35.97 0.2 130 7.0 72 10.83 42.52 na 74 10.83 8 40.86 na 51.14 0.25 90 7.0 75 10.83 44.78 na The maximum velocity is 25.3 and it occurs in the pipe between nodes 34 and M03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC HOEHN OIL ROOM CALC Hyd. Qa Dia. Fitting Ref. "C" or Point Qt Pf/Ft Eqv. Ln. Page 6 Date Pipe Pt Pt Ftng's Pe Pv ******* Notes ****** Total Pf Pn 1 26.18 1.408 0.0 7.450 21.852 K Factor =5.60 to 120.0 0.0 0.0 0.0 2 26.18 0.0511 0.0 7.450 0.381 Vel = 5.39 2 26.40 1.408 E 3.308 16.160 22.233 K Factor =5.60 to 120.0 0.0 3.308 0.0 3 52.58 0.1855 0.0 19.468 3.612 Vel = 10.83 3 27.44 1.408 0.0 1.500 25.845 to 120.0 0.0 0.0 0.0 4 80.02 0.4040 0.0 1.500 0.606 Vel = 16.49 4 28.26 1.408 2T 13.233 5.380 26.451 to 120.0 E 3.308 16.541 0.719 M04 108.28 0.7062 0.0 21.921 15.480 Vel = 22.31 M04 477.61 6.357 0.0 25.000 42.650 to 120.0 0.0 0.0 0.0 M05 585.89 0.0104 0.0 25.000 0.260 Vel = 5.92 M05 96.30 6.357 0.0 9.040 42.910 to 120.0 0.0 0.0 0.0 JA 682.19 0.0137 0.0 9.040 0.124 Vel = 6.90 JA 133.85 6.357 T 37.72 7.320 43.034 to 120.0 0.0 37.720 0.0 M06 816.04 0.0192 0.0 45.040 0.865 Vet = 8.25 M06 70.33 6.357 2E 35.205 8.780 43.899 to 120.0 0.0 35.205 0.0 M07 886.37 0.0224 0.0 43.985 0.985 Vel = 8.96 M07 70.76 6.357 2E 35.205 7.330 44.884 to 120.0 0.0 35.205 0.0 M08 957.13 0.0258 0.0 42.535 1.097 Vel = 9.68 M08 71.86 6.357 F 8.801 11.550 45.981 to 120.0 0.0 8.801 0.0 M09 1028.99 0.0295 0.0 20.351 0.601 Vel = 10.40 M09 96.46 6.357 0.0 8.920 46.582 to 120.0 0.0 0.0 0.0 M10 1125.45 0.0348 0.0 8.920 0.310 VeI= 11.38 MIO 51.14 6.357 E 17.603 3.250 46.892 to 120.0 0.0 17.603 0.0 TOR 1176.59 0.0378 0.0 20.853 0.788 VeI= 11.89 TOR 0.0 6.357 E 17.603 7.170 47.680 to 120.0 T 37.72 108.131 3.105 BOR 1176.59 0.0378 B 12.573 115.301 4.359 VeI= 11.89 S 40.235 BOR 0.0 6.357 E 17.603 9.000 55.144 to 120.0 T 37.72 55.323 0.0 UGI 1176.59 0.0378 0.0 64.323 2.431 Vel = 11.89 UGI 0.0 6.09 7E 151.081 150.000 57.575 to 150.0 0.0 151.080 0.866 UG2 1176.59 0.0308 0.0 301.080 9.282 Vel = 12.96 UG2 0.0 6.09 0.0 5.000 67.723 to 150.0 0.0 0.0 9.000 * * Fixed Loss = 9 UG3 1176.59 0.0308 0.0 5.000 0.154 Vel = 12.96 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 7 HOEHN OIL ROOM CALC Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG3 0.0 6.16 E 20.084 16.000 76.877 to 140.0 T 43.037 63.121 0.0 HYD 1176.59 0.0331 0.0 79.121 2.621 Vel = 12.67 HYD 500.00 6.16 E 20.084 2.500 79.498 Qa = 500 to 140.0 G 4.304 67.425 1.429 TEST 1676.59 0.0638 T 43.037 69.925 4.461 Vet = 18.05 0.0 1676.59 85.388 K Factor = 181.44 114 27.44 1.08 T 5.762 3.330 24.003 K Factor =5.60 to 120.0 0.0 5.762 0.0 3 27.44 0.2026 0.0 9.092 1.842 Vel = 9.61 0.0 27.44 25.845 K Factor= 5.40 15 28.27 1.08 E 2.305 0.840 25.477 K Factor =5.60 to 120.0 0.0 2.305 0.0 16 28.27 0.2140 0.0 3.145 0.673 Vel = 9.90 16 0.0 1.408 0.0 5.100 26.150 to 120.0 0.0 0.0 0.0 4 28.27 0.0590 0.0 5.100 0.301 Vel = 5.83 0.0 28.27 26.451 K Factor= 5.50 M04 -477.60 6.357 T 37.72 7.250 42.650 to 120.0 0.0 37.720 3.972 14 -477.6 -0.0072 0.0 44.970 -0.322 Vel = 40'83 0.0 -477.60 46.300 K Factor = -70.19 19 30.00 1.408 0.0 12.000 28.706 K Factor 5.60 to 120.0 0.0 0.0 0.0 20 30.0 0.0657 0.0 12.000 0.788 Vet = 6.18 20 30.42 1.408 T 6.617 9.720 29.494 K Factor =5.60 to 120.0 0.0 6.617 0.0 21 60.42 0.2399 0.0 16.337 3.920 Vet = 12.45 0.0 60.42 33.414 KFactor= 10.45 22 30.91 1.408 0.0 10.000 30.469 K Factor =5.60 to 120.0 0.0 0.0 0.0 23 30.91 0.0694 0.0 10.000 0.694 Vel = 6.37 23 31.26 1.408 T 6.617 2.280 31.163 K Factor =5.60 to 120.0 0.0 6.617 0.0 21 62.17 0.2530 0.0 8.897 2.251 Vet = 12.81 21 60.42 1.408 T 6.617 1.670 33.414 to 120.0 0.0 6.617 0.719 MOI 122.59 0.8884 0.0 8.287 7.362 Vet = 25.26 MOI -34.15 4.31 0.0 9.000 41.495 to 120.0 0.0 0.0 0.0 M02 88.44 0.0021 0.0 9.000 0.019 Vel = 1.94 M02 122.62 4.31 0.0 9.000 41.514 to 120.0 0.0 0.0 0.0 M03 211.06 0.0104 0.0 9.000 0.094 VeI= 4.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 8 HOEHN OIL ROOM CALC Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn M03 122.76 4.31 T 27.874 1.680 41.608 to 120.0 0.0 27.874 3.972 14 333.82 0.0244 0.0 29.554 0.720 Vel = 7.34 0.0 333.82 46.300 K Factor= 49.06 27 30.01 1.408 0.0 12.000 28.719 K Factor =5.60 to 120.0 0.0 0.0 0.0 28 30.01 0.0658 0.0 12.000 0.789 Vel = 6.18 28 30.42 1.408 T 6.617 9.720 29.508 K Factor =5.60 to 120.0 0.0 6.617 0.0 29 60.43 0.2401 0.0 16.337 3.922 Vel = 12.45 0.0 60.43 33.430 KFactor= 10.45 30 30.92 1.408 0.0 10.000 30.483 K Factor =5.60 to 120.0 0.0 0.0 0.0 31 30.92 0.0695 0.0 10.000 0.695 Vel = 6.37 31 31.27 1.408 1 6.617 2.280 31.178 K Factor =5.60 to 120.0 0.0 6.617 0.0 29 62.19 0.2531 0.0 8.897 2.252 Vel = 12.81 29 60.43 1.408 T 6.617 1.670 33.430 to 120.0 0.0 6.617 0.719 M02 122.62 0.8887 0.0 8.287 7.365 Vel = 25.27 0.0 122.62 41.514 KFactor= 19.03 32 30.05 1.408 0.0 12.000 28.787 K Factor =5.60 to 120.0 0.0 0.0 0.0 33 30.05 0.0659 0.0 12.000 0.791 Vel = 6.19 33 30.45 1.408 T 6.617 9.720 29.578 K Factor =5.60 to 120.0 0.0 6.617 0.0 34 60.5 0.2406 0.0 16.337 3.930 Vel = 12.47 0.0 60.50 33.508 KFactor= 10.45 35 30.95 1.408 0.0 10.000 30.555 K Factor =5.60 to 120.0 0.0 0.0 0.0 36 30.95 0.0696 0.0 10.000 0.696 Vel = 6.38 36 31.31 1.408 1 6.617 2.280 31.251 K Factor =5.60 to 120.0 0.0 6.617 0.0 34 62.26 0.2537 0.0 8.897 2.257 Vel = 12.83 34 60.50 1.408 T 6.617 1.670 33.508 to 120.0 0.0 6.617 0.719 M03 122.76 0.8907 0.0 8.287 7.381 Vel = 25.30 0.0 122.76 41.608 KFactor= 19.03 37 26.00 1.408 0.0 7.125 21.556 K Factor =5.60 to 120.0 0.0 0.0 0.0 337 26.0 0.0504 0.0 7.125 0.359 Vel = 5.36 337 26.22 1.408 0.0 12.250 21.915 K Factor =5.60 to 120.0 0.0 0.0 0.0 38 52.22 0.1832 0.0 12.250 2.244 Vel = 10.76 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 9 HOEHN OIL ROOM CALC Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 38 27.52 1.408 4E 13.233 15.140 24.159 K Factor =5.60 to 120.0 T 6.617 19.850 0.0 39 79.74 0.4009 0.0 34.990 14.029 Vel = 16.43 39 0.0 2.703 0.0 3.260 38.188 to 120.0 0.0 0.0 0.0 40 79.74 0.0169 0.0 3.260 0.055 Vel = 4.46 40 64.04 2.703 3E 27.976 20.980 38.243 to 120.0 T 18.651 46.627 4.690 14 143.78 0.0498 0.0 67.607 3.367 Vel = 8.04 0.0 143.78 46.300 KFactor 21.13 41 31.51 1.408 0.0 9.000 31.653 K Factor =5.60 to 120.0 0.0 0.0 0.0 42 31.51 0.0719 0.0 9.000 0.647 Vel = 6.49 42 31.82 1.408 0.0 9.000 32.300 K Factor =5.60 to 120.0 0.0 0.0 0.0 43 63.33 0.2618 0.0 9.000 2.356 Vel = 13.05 43 32.97 1.408 E 3.308 3.330 34.656 K Factor = 5.60 to 120.0 1 6.617 9.925 0.719 M05 96.3 0.5685 0.0 13.255 7.535 Vel = 19.84 0.0 96.30 42.910 KFactor= 14.70 45 31.98 1.408 T 6.617 4.700 32.620 K Factor =5.60 to 120.0 0.0 6.617 0.0 46 31.98 0.0740 0.0 11.317 0.838 VeI= 6.59 46 32.06 1.408 T 6.617 11.290 33.458 to 120.0 0.0 6.617 0.0 40 64.04 0.2672 0.0 17.907 4.785 Vel = 13.20 0.0 64.04 38.243 KFactor= 10.36 47 32.05 1.408 0.0 9.370 32.762 K Factor = 5.60 to 120.0 0.0 0.0 0.0 46 32.05 0.0743 0.0 9.370 0.696 Vel = 6.60 0.0 32.05 33.458 K Factor= 5.54 48 32.62 1.408 0.0 9.000 33.937 K Factor = 5.60 to 120.0 0.0 0.0 0.0 49 32.62 0.0767 0.0 9.000 0.690 Vel = 6.72 49 32.96 1.408 0.0 9.000 34.627 K Factor = 5.60 to 120.0 0.0 0.0 0.0 50 65.58 0.2792 0.0 9.000 2.513 Vel = 13.51 50 34.12 1.408 1 6.617 1.680 37.140 K Factor =5.60 to 120.0 0.0 6.617 0.0 M51 99.7 0.6062 0.0 8.297 5.030 Vel = 20.54 M51 34.15 4.31 2E 27.874 4.550 42.170 to 120.0 0.0 27.874 0.719 JA 133.85 0.0045 0.0 32.424 0.145 Vel = 2.94 --- 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 10 HOEHN OIL ROOM CALC Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 133.85 43.034 K Factor= 20.40 M51 -34.14 4.31 2E 27.874 31.750 42.170 to 120.0 0.0 27.874 -0.039 M52 -34.14 -0.0004 0.0 59.624 -0.022 Vel = 0.75 M52 10.98 4.31 0.0 14.180 42.109 to 120.0 0.0 0.0 0.0 M53 -23.16 -0.0001 0.0 14.180 -0.002 Vel = 0.51 M53 11.57 4.31 0.0 12.900 42.107 to 120.0 0.0 0.0 0.0 M54 -11.59 -0.0001 0.0 12.900 -0.001 VeI= 0.25 M54 0.0 1.408 2T 13.233 93.140 42.106 to 120.0 2E 6.617 19.850 0.0 M55 -11.59 -0.0113 0.0 112.990 -1.277 VeI= 2.39 M55 0.0 4.31 0.0 13.140 40.829 to 120.0 0.0 0.0 0.0 M56 -11.59 -0.0001 0.0 13.140 -0.001 Vel = 0.25 M56 -11.57 4.31 2E 27.874 19.750 40.828 to 120.0 0.0 27.874 0.689 M57 -23.16 -0.0002 0.0 47.624 -0.009 Vel = 0.51 M57 -10.98 4.31 3E 41.811 60.900 41.508 to 120.0 T 27.874 69.685 0.069 M59 -34.14 -0.0004 0.0 130.585 -0.046 Vel = 0.75 M59 0.0 4.31 E 13.937 85.610 41.531 to 120.0 0.0 13.937 0.0 M01 -34.14 -0.0004 0.0 99.547 -0.036 Vel = 0.75 0.0 -34.14 41.495 K Factor= -5.30 60 47.82 1.08 E 2.305 3.730 35.726 K Factor =8.00 to 120.0 T 5.762 8.067 0.0 61 47.82 0.5664 0.0 11.797 6.682 VeI= 16.75 61 48.64 2.104 E 5.451 26.500 42.408 to 120.0 T 10.902 16.353 0.719 M09 96.46 0.0806 0.0 42.853 3.455 Vet = 8.90 0.0 96.46 46.582 KFactor= 14.13 63 48.64 1.08 T 5.762 3.520 36.970 K Factor = 8.00 to 120.0 0.0 5.762 0.0 64 48.64 0.5846 0.0 9.282 5.426 Vel = 17.03 64 0.0 2.104 0.0 0.500 42.396 to 120.0 0.0 0.0 0.0 61 48.64 0.0240 0.0 0.500 0.012 Vel = 4.49 0.0 48.64 42.408 K Factor= 7.47 65 35.05 1.408 T 6.617 9.040 39.174 K Factor =5.60 to 120.0 0.0 6.617 0.0 66 35.05 0.0876 0.0 15.657 1.372 Vel = 7.22 0.0 35.05 40.546 K Factor= 5.50 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 11 HOEHN OIL ROOM CALC Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 67 35.29 1.408 T 6.617 2.870 39.705 K Factor 5.60 to 120.0 0.0 6.617 0.0 66 35.29 0.0886 0.0 9.487 0.841 Vet = 7.27 66 35.05 1.408 T 6.617 1.670 40.546 to 120.0 0.0 6.617 0.719 M06 70.34 0.3178 0.0 8.287 2.634 Vet = 14.49 0.0 70.34 43.899 K Factor= 10.62 68 35.28 1.408 T 6.617 9.040 39.686 K Factor =5.60 to 120.0 0.0 6.617 0.0 69 35.28 0.0887 0.0 15.657 1.388 VeI= 7.27 0.0 35.28 41.074 KFactor= 5.50 70 35.48 1.408 T 6.617 3.870 40.134 K Factor =5.60 to 120.0 0.0 6.617 0.0 69 35.48 0.0896 0.0 10.487 0.940 Vet = 7.31 69 35.28 1.408 T 6.617 3.000 41.074 to 120.0 0.0 6.617 0.719 M07 70.76 0.3214 0.0 9.617 3.091 Vet = 14.58 0.0 70.76 44.884 K Factor = 10.56 71 35.90 1.408 T 6.617 9.040 41.088 K Factor =5.60 to 120.0 0.0 6.617 0.0 72 35.9 0.0916 0.0 15.657 1.434 Vet = 7.40 0.0 35.90 42.522 K Factor= 5.51 73 35.97 1.408 E 3.308 3.910 41.250 K Factor 5.60 to 120.0 T 6.617 9.925 0.0 72 35.97 0.0919 0.0 13.835 1.272 Vet = 7.41 72 35.89 1.408 T 6.617 1.670 42.522 to 120.0 0.0 6.617 0.719 MOB 71.86 0.3306 0.0 8.287 2.740 Vet = 14.81 0.0 71.86 45.981 KFactor= 10.60 74 51.14 1.08 T 5.762 0.350 40.864 K Factor 8.00 to 120.0 0.0 5.762 0.0 75 51.14 0.6414 0.0 6.112 3.920 Vet= 17.91 75 0.0 2.104 3E 16.354 28.500 44.784 to 120.0 T 10.902 27.256 0.719 M10 51.14 0.0249 0.0 55.756 1.389 Vet = 4.72 0.0 51.14 46.892 KFactor= 7.47 M57 10.98 1.408 2E 6.617 99.500 41.508 to 120.0 3T 19.85 26.467 -0.689 M52 10.98 0.0102 0.0 125.967 1.290 Vet = 2.26 0.0 10.98 42.109 KFactor= 1.69 M56 11.58 1.408 2T 13.233 93.370 40.828 to 120.0 2E 6.617 19.850 0.0 M53 11.58 0.0113 0.0 113.220 1.279 Vet= 2.39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 12 HOEHN OIL ROOM CALC Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv, Ln. Total Pf Pn 0.0 11.58 42.107 KFactor 1.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - Fire Protection by Computer Design PARAMOUNT FIRE SYSTEMS, INC C-16 788204 Job Name : HOEHN Level 2-A PARTS Building : LEVEL 2 Location : 6800 AVENIDA ENCINAS System : 1-2-A Contract Data File : HOEHN Level 2 Area 1 PARTS STORAGE REV 2 submittal.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PARAMOUNT FIRE SYSTEMS, INC Page HOEHN Level 2-A PARTS Date HYDRAULIC CALCULATIONS for Project name: HOEHN PORSCHE Location: 6800 AVENIDA ENCINAS Drawing no: LEVEL 2 Date: 8-17 Design Remote area number: 1-2-A Remote area location: LEVEL 2 PARTS STORAGE TIRE CAROUSEL Occupancy classification: STORAGE DENSITIES Density: .30/.9 - Gpm/SqFt Area of application: 2293 - SqFt Coverage per sprinkler: 91 - SqFt Type of sprinklers calculated: 11.2K SSP/16.8K SSP No. of sprinklers calculated: 35 In-rack demand: NA - GPM Hose streams: 750 - GPM Total water required (including hose streams): 2216.6 -GPM © 89.9 - Psi Type of system: WET GRID Volume of dry or preaction system: NA - Gal Water supply information Date: 6-23-17 Location: 12" MAIN © 6800 AVEN IDA ENCINAS Source: CFD WATER AVAILABILITY FORM Name of contractor: PARAMOUNT FIRE SYSTEMS INC Address: 8069 WING AVENUE EL CAJON, CA Phone number: 619 562-6247 Name of designer: JAMES CHENEY Authority ha ving jurisdiction: CARLSBAD FIRE PREVENTION BUREAU Notes: (Include peaking information or gridded systems here.) .30 GPM SQ. FT. REQUIRED FOR PARTS STORAGE PER NFPA 13 15.2.2 FIGURES 15.2.2.1 AND 17.2.1.2.1(a) .90 ENTIRE TIRE CARAOUSEL ENCLOSURE PER NFPA 13 TABLE 18.4(a) AND 12.8.6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C PARAMOUNT FIRE SYSTEMS, INC Page 2 HOEHN Level 2-A PARTS Date City Water Supply: Demand: Cl - Static Pressure : 100.8 Dl - Elevation : 11.391 C2 - Residual Pressure: 76.5 02 - System Flow :1466.56 C2 - Residual Flow : 6425 D2 - System Pressure : 89.908 Hose ( Demand) : 750 D3 - System Demand : 2216.56 Safety Margin : 7.499 150 - 140 130 p120 R 11 ci 100 02 S 90 C2 S 80 D3 - -__ U 70 R 60 E 50 40 30 20 10 m —.I I 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PARAMOUNT FIRE SYSTEMS, INC Page 3 HOEHN Level 2-A PARTS Date Fitting Legend Abbrev. Name % % 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390 Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD PARAMOUNT FIRE SYSTEMS, INC Page 4 HOEHN Level 2-A PARTS Date Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 2 23.0 11.2 8.33 na 32.32 0.3 91 7.0 3 23.0 11.2 10.71 na 36.65 0.3 91 7.0 4 23.0 11.2 11.59 na 38.12 0.3 91 7.0 5 23.0 11.2 13.01 na 40.4 0.3 91 7.0 6 23.0 19.87 na 776 23.0 20.0 na 7 23.0 20.0 na 8 23.0 20.14 na 9 23.0 20.14 na 10 23.0 20.15 na 11 23.0 20.18 na 12 23.0 20.19 na 13 23.0 20.19 na 14 23.0 20.19 na 15 23.0 23.02 na 16 23.0 24.99 na 17 23.0 24.99 na 18 23.0 25.01 na 19 23.0 25.03 na 20 23.0 25.22 na 277 23.0 25.55 na 21 23.0 30.16 na TOR 23.0 35.07 na BOR 2.0 49.36 na UG1 2.0 53.01 na UG2 0.0 67.83 na UG3 0.0 77.06 na HYD 0.0 81.0 na 750.0 TEST -3.3 89.91 na 27 23.0 11.2 7.16 na 29.96 0.3 91 7.0 28 23.0 7.75 na 29S 23.0 11.2 7.12 na 29.88 0.3 91 7.0 29 23.0 7.72 na 30 23.0 19.89 na 31 23.0 19.97 na 32 23.0 20.73 na 33 23.0 21.26 na Ji 23.0 21.37 na 34 23.0 21.33 na 35 23.0 21.33 na 80 23.0 21.33 na 36 23.0 21.34 na Al 23.0 21.35 na 37 23.0 21.36 na 38 23.0 27.37 na A2 23.0 27.37 na 39 23.0 27.38 na 239 23.0 27.45 na 40 23.0 11.2 11.68 na 38.27 0.3 91 7.0 41 23.0 16.8 11.76 na 57.6 0.9 64 7.0 42 23.0 16.8 11.94 na 58.06 0.9 64 7.0 43 23.0 16.8 12.4 na 59.15 0.9 64 7.0 46 23.0 11.2 8.59 na 32.83 0.3 91 7.0 47 23.0 11.2 8.66 na 32.96 0.3 91 7.0 48 23.0 11.2 8.91 na 33.44 0.3 91 7.0 49 23.0 11.2 9.46 na 34.44 0.3 91 7.0 449 23.0 9.53 na 450 23.0 11.2 8.71 na 33.05 0.3 81 7.0 50 23.0 11.2 9.14 na 33.86 0.3 91 7.0 51 23.0 11.2 10.48 na 36.26 0.3 91 7.0 52 23.0 11.2 10.81 na 36.83 0.3 91 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard PARAMOUNT FIRE SYSTEMS, INC Page 5 HOEHN Level 2-A PARTS Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 53 23.0 11.2 11.59 na 38.13 0.3 91 7.0 54 23.0 11.2 14.24 na 42.26 0.3 80 7.0 55 23.0 11.2 14.37 na 42.45 0.3 80 7.0 56 23.0 11.2 14.87 na 43.19 0.3 80 7.0 65 23.0 11.2 14.49 na 42.64 0.3 91 7.0 66 23.0 11.2 15.1 na 43.53 0.3 91 7.0 67 23.0 11.2 15.66 na 4432 0.3 91 7.0 677 23.0 11.2 16.66 na 45.72 0.3 91 7.0 68 23.0 11.2 13.64 na 41.37 0.3 91 7.0 69 23.0 11.2 14.04 na 41.96 0.3 91 7.0 70 23.0 11.2 15.9 na 44.66 0.3 91 7.0 709 23.0 11.2 16.87 na 46.0 0.3 91 7.0 71 23.0 11.2 14.29 na 42.33 0.3 80 7.0 72 23.0 11.2 14.42 na 42.53 0.3 80 7.0 73 23.0 11.2 14.93 na 43.27 0.3 80 7.0 74 23.0 11.2 14.29 na 42.33 0.3 80 7.0 75 23.0 11.2 14.42 na 42.52 0.3 80 7.0 76 23.0 11.2 14.92 na 43.27 0.3 80 7.0 The maximum velocity is 23.86 and it occurs in the pipe between nodes HYD and TEST Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 6 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe PV Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 2 92.16 2.203 4E 27.277 12.916 8.326 KFactor= 11.20 to 120.0 0.0 27.277 0.0 3 92.16 0.0592 0.0 40.193 2.380 Vel = 7.76 3 36.64 2.203 0.0 8.000 10.706 K Factor = 11.20 to 120.0 0.0 0.0 0.0 4 128.8 0.1101 0.0 8.000 0.881 Vel = 10.84 4 38.13 2.203 0.0 8.000 11.587 KFactor= 11.20 to 120.0 0.0 0.0 0.0 5 166.93 0.1778 0.0 8.000 1.422 VeI= 14.05 5 40.39 2.203 E 6.819 5.375 13.009 K Factor = 11.20 to 120.0 T 13.639 20.458 0.0 6 207.32 0.2654 0.0 25.833 6.857 Vel = 17.45 6 -47.08 4.31 E 13.937 7.500 19.866 to 120.0 0.0 13.937 0.0 776 160.24 0.0063 0.0 21.437 0.135 Vel = 3.52 776 -25.33 4.31 0.0 0.750 20.001 to 120.0 0.0 0.0 0.0 7 134.91 0.0040 0.0 0.750 0.003 Vel = 2.97 7 176.20 4.31 0.0 6.350 20.004 to 120.0 0.0 0.0 0.0 8 311.11 0.0214 0.0 6.350 0.136 Vel= 6.84 8 -379.85 4.31 0.0 1.916 20.140 to 120.0 0.0 0.0 0.0 9 -68.74 -0.0010 0.0 1.916 -0.002 VeI= 1.51 9 174.00 4.31 0.0 5.916 20.138 to 120.0 0.0 0.0 0.0 10 105.26 0.0029 0.0 5.916 0.017 Vel = 2.31 10 -23.13 4.31 0.0 11.780 20.155 to 120.0 0.0 0.0 0.0 11 82.13 0.0018 0.0 11.780 0.021 Vel= 1.81 11 -23.03 4.31 0.0 10.980 20.176 to 120.0 0.0 0.0 0.0 12 59.1 0.0010 0.0 10.980 0.011 Vel = 1.30 12 -22.97 4.31 0.0 11.042 20.187 to 120.0 0.0 0.0 0.0 13 36.13 0.0004 0.0 11.042 0.004 Vel = 0.79 13 -19.18 4.31 2E 27.874 3.292 20.191 to 120.0 0.0 27.874 0.0 14 16.95 0.0001 0.0 31.166 0.003 Vel = 0.37 14 0.0 1.408 3E 9.925 100.292 20.194 to 120.0 2T 13.233 23.158 0.0 15 16.95 0.0229 0.0 123.450 2.823 Vel = 3.49 15 19.18 1.408 T 6.617 14.666 23.017 to 120.0 0.0 6.617 0.0 16 36.13 0.0927 0.0 21.283 1.973 Vel = 7.44 16 0.0 4.31 0.0 12.000 24.990 to 120.0 0.0 0.0 0.0 17 36.13 0.0004 0.0 12.000 0.005 Vel = 0.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 7 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 17 22.97 4.31 0.0 11.000 24.995 to 120.0 0.0 0.0 0.0 18 59.1 0.0010 0.0 11.000 0.011 Vel= 1.30 18 23.03 4.31 0.0 11.780 25.006 to 120.0 0.0 0.0 0.0 19 82.13 0.0018 0.0 11.780 0.021 Vel= 1.81 19 23.13 4.31 2E 27.874 11.000 25.027 to 120.0 T 27.874 55.748 0.0 20 105.26 0.0029 0.0 66.748 0.193 Vel = 2.31 20 379.85 4.26 0.0 6.416 25.220 to 120.0 0.0 0.0 0.0 277 485.11 0.0514 0.0 6.416 0.330 Vel= 10.92 277 25.33 4.26 T 26.334 55.125 25.550 to 120.0 0.0 26.334 0.0 21 510.44 0.0566 0.0 81.459 4.614 Vet = 11.49 21 -1466.55 6.357 4E 70.411 33.790 30.164 to 120.0 0.0 70.411 9.961 22 -956.11 -0.0257 0.0 104.201 -2.683 Vel = 9.66 0.0 -956.11 37.442 K Factor = -156.25 21 1466.56 6.357 3E 52.808 33.542 30.164 to 120.0 0.0 52.808 0.0 TOR 1466.56 0.0568 0.0 86.350 4.906 Vel = 14.82 TOR 0.0 6.357 E 17.603 21.000 35.070 to 120.0 B 12.573 70.411 9.095 BOR 1466.56 0.0568 S 40.235 91.411 5.194 Vet= 14.82 BOR 0.0 6.357 E 17.603 9.000 49.359 to 120.0 T 37.72 55.323 0.0 UGI 1466.56 0.0568 0.0 64.323 3.655 Vet = 14.82 UG1 0.0 6.09 7E 151.081 150.000 53.014 to 150.0 0.0 151.080 0.866 UG2 1466.56 0.0463 0.0 301.080 13.951 Vet= 16.15 UG2 0.0 6.09 0.0 5.000 67.831 to 150.0 0.0 0.0 9.000 * * Fixed Loss = 9 UG3 1466.56 0.0464 0.0 5.000 0.232 Vel = 16.15 UG3 0.0 6.16 E 20.084 16.000 77.063 to 140.0 T 43.037 63.121 0.0 HYck , 1466.56 0.0498 0.0 79.121 3.940 Vel = 15.79 HYD 750.00 6.16 E 20.084 2.500 81.003 Qa = 750 to 140.0 G 4.304 67.425 1.429 TEST 2216.56 0.1069 T 43.037 69.925 7.476 Vet = 23.86 0.0 2216.56 89.908 K Factor = 233.77 27 29.96 1.408 1 6.617 2.375 7.156 K Factor= 11.20 to 120.0 0.0 6.617 0.0 28 29.96 0.0656 0.0 8.992 0.590 Vel = 6.17 28 29.88 2.203 2E 13.639 8.125 7.746 to 120.0 0.0 13.639 0.0 2 59.84 0.0266 0.0 21.764 0.580 Vel = 5.04 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 8 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 59.84 8.326 KFactor= 20.74 29S 29.88 1.408 T 6.617 2.625 7.117 K Factor = 11.20 to 120.0 0.0 6.617 0.0 29 29.88 0.0652 0.0 9.242 0.603 Vel = 6.16 29 0.0 2.203 0.0 3.500 7.720 to 120.0 0.0 0.0 0.0 28 29.88 0.0074 0.0 3.500 0.026 Vel = 2.52 0.0 29.88 7.746 K Factor= 10.74 6 47.08 4.31 2E 27.874 12.666 19.866 to 120.0 0.0 27.874 0.0 30 47.08 0.0006 0.0 40.540 0.026 Vel = 1.04 30 166.73 4.31 0.0 7.240 19.892 to 120.0 0.0 0.0 0.0 31 213.81 0.0108 0.0 7.240 0.078 Vel = 4.70 31 213.07 4.31 0.0 19.832 19.970 to 120.0 0.0 0.0 0.0 32 426.88 0.0384 0.0 19.832 0.762 Vel = 9.39 32 145.08 4.31 0.0 8.000 20.732 to 120.0 0.0 0.0 0.0 33 571.96 0.0661 0.0 8.000 0.529 VeI= 12.58 33 127.90 4.31 0.0 1.125 21.261 to 120.0 0.0 0.0 0.0 J1 699.86 0.0960 0.0 1.125 0.108 Vel = 15.39 Ji -862.97 4.31 0.0 5.875 21.369 to 120.0 0.0 0.0 0.0 34 -163.11 -0.0065 0.0 5.875 -0.038 Vel = 3.59 34 128.13 4.31 0.0 6.750 21.331 to 120.0 0.0 0.0 0.0 35 -34.98 -0.0004 0.0 6.750 -0.003 Vel = 0.77 35 128.12 4.31 0.0 0.500 21.328 to 120.0 0.0 0.0 0.0 80 93.14 0.0020 0.0 0.500 0.001 Vet = 2.05 80 -20.45 4.31 0.0 10.500 21.329 to 120.0 0.0 0.0 0.0 36 72.69 0.0014 0.0 10.500 0.015 Vel = 1.60 36 -24.56 4.31 0.0 5.833 21.344 to 120.0 0.0 0.0 0.0 Al 48.13 0.0007 0.0 5.833 0.004 Vet = 1.06 Al -24.55 4.31 2E 27.874 12.250 21.348 to 120.0 0.0 27.874 0.0 37 23.58 0.0002 0.0 40.124 0.008 Vel = 0.52 37 0.0 1.408 2E 6.617 123.000 21.356 to 120.0 2T 13.233 19.850 0.0 38 23.58 0.0421 0.0 142.850 6.011 Vel = 4.86 38 0.0 4.31 2E 27.874 12.250 27.367 to 120.0 0.0 27.874 0.0 A2 23.58 0.0002 0.0 40.124 0.007 Vel = 0.52 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 9 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn A2 24.55 4.31 0.0 6.042 27.374 to 120.0 0.0 0.0 0.0 39 48.13 0.0007 0.0 6.042 0.004 Vel = 1.06 39 24.56 4.31 2E 27.874 20.584 27.378 to 120.0 0.0 27.874 0.0 239 72.69 0.0014 0.0 48.458 0.070 Vel = 1.60 239 20.45 4.31 0.0 14.250 27.448 to 120.0 0.0 0.0 9.961 22 93.14 0.0023 0.0 14.250 0.033 Vet = 2.05 0.0 93.14 37.442 KFactor= 15.22 40 38.27 2.203 0.0 6.875 11.675 K Factor = 11.20 to 120.0 0.0 0.0 0.0 41 38.27 0.0116 0.0 6.875 0.080 Vet = 3.22 41 57.60 2.703 0.0 8.000 11.755 K Factor = 16.80 to 120.0 0.0 0.0 0.0 42 95.87 0.0235 0.0 8.000 0.188 Vet = 5.36 42 58.06 2.703 0.0 8.000 11.943 K Factor = 16.80 to 120.0 0.0 0.0 0.0 43 153.93 0.0565 0.0 8.000 0.452 Vet = 8.61 43 59.15 2.703 4E 37.301 17.500 12.395 K Factor = 16.80 to 120.0 T 18.651 55.952 0.0 31 213.08 0.1031 0.0 73.452 7.575 VeI= 11.91 0.0 213.08 19.970 KFactor= 47.68 46 32.83 2.203 0.0 8.000 8.590 K Factor = 11.20 to 120.0 0.0 0.0 0.0 47 32.83 0.0089 0.0 8.000 0.071 Vel = 2.76 47 32.96 2.203 0.0 8.000 8.661 K Factor= 11.20 to 120.0 0.0 0.0 0.0 48 65.79 0.0318 0.0 8.000 0.254 Vet = 5.54 48 33.44 2.203 0.0 8.000 8.915 KFactor= 11.20 to 120.0 0.0 0.0 0.0 49 99.23 0.0679 0.0 8.000 0.543 Vet = 8.35 49 34.44 2.203 0.0 0.625 9.458 K Factor = 11.20 to 120.0 0.0 0.0 0.0 449 133.67 0.1168 0.0 0.625 0.073 Vet = 11.25 449 33.05 2.203 4E 27.277 17.500 9.531 to 120.0 T 13.639 40.916 0.0 30 166.72 0.1774 0.0 58.416 10.361 Vet= 14.03 0.0 166.72 19.892 KFactor= 37.38 450 33.05 1.408 T 6.617 3.833 8.710 K Factor = 11.20 to 120.0 0.0 6.617 0.0 449 33.05 0.0786 0.0 10.450 0.821 Vet = 6.81 0.0 33.05 9.531 KFactor= 10.71 50 33.86 1.38 E 3.0 11.833 9.137 K Factor = 11.20 to 120.0 0.0 3.000 0.0 51 33.86 0.0907 0.0 14.833 1.345 Vet = 7.26 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 10 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 51 36.26 2.203 0.0 9.250 10.482 KFactor= 11.20 to 120.0 0.0 0.0 0.0 52 70.12 0.0357 0.0 9.250 0.330 Vel = 5.90 52 36.82 2.203 0.0 10.000 10.812 K Factor = 11.20 to 120.0 0.0 0.0 0.0 53 106.94 0.0780 0.0 10.000 0.780 Vel = 9.00 53 38.14 2.203 5E 34.097 18.920 11.592 KFactor= 11.20 to 120.0 T 13.639 47.736 0.0 32 145.08 0.1371 0.0 66.656 9.140 Vel = 12.21 0.0 145.08 20.732 KFactor= 31.86 54 42.26 2.203 0.0 9.250 14.236 K Factor = 11.20 to 120.0 0.0 0.0 0.0 55 42.26 0.0141 0.0 9.250 0.130 Vel = 3.56 55 42.45 2.203 0.0 10.000 14.366 K Factor = 11.20 to 120.0 0.0 0.0 0.0 56 84.71 0.0506 0.0 10.000 0.506 Vel = 7.13 56 43.19 2.203 4E 27.277 17.900 14.872 KFactor= 11.20 to 120.0 T 13.639 40.916 0.0 33 127.9 0.1086 0.0 58.816 6.389 Vel = 10.77 0.0 127.90 21.261 KFactor= 27.74 JI 862.97 6.357 21 75.44 141.100 21.369 to 120.0 4E 70.411 145.851 9.961 22 862.97 0.0213 0.0 286.951 6.112 Vel = 8.72 0.0 862.97 37.442 K Factor = 141.03 65 42.64 2.203 4E 27.277 15.500 14.495 KFactor= 11.20 to 120.0 0.0 27.277 0.0 66 42.64 0.0142 0.0 42.777 0.609 Vel = 3.59 66 43.53 2.203 0.0 10.600 15.104 K Factor= 11.20 to 120.0 0.0 0.0 0.0 67 86.17 0.0523 0.0 10.600 0.554 Vel = 7.25 67 44.32 2.203 0.0 8.900 15.658 KFactor= 11.20 to 120.0 0.0 0.0 0.0 677 130.49 0.1127 0.0 8.900 1.003 VeI= 10.98 677 45.71 2.203 1 13.639 3.375 16.661 K Factor = 11.20 to 120.0 0.0 13.639 0.0 7 176.2 0.1965 0.0 17.014 3.343 Vel = 14.83 0.0 176.20 20.004 K Factor= 39.40 68 41.37 2.203 2E 13.639 15.500 13.644 KFactor= 11.20 to 120.0 0.0 13.639 0.0 69 41.37 0.0135 0.0 29.139 0.393 Vel= 3.48 69 41.96 2.203 4E 27.277 10.660 14.037 KFactor= 11.20 to 120.0 0.0 27.277 0.0 70 83.33 0.0492 0.0 37.937 1.865 Vel = 7.01 70 44.67 2.203 0.0 8.916 15.902 K Factor = 11.20 to 120.0 0.0 0.0 0.0 709 128.0 0.1088 0.0 8.916 0.970 Vel = 10.77 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 11 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total P1 Pn 709 46.00 2.203 T 13.639 3.375 16.872 KFactor= 11.20 to 120.0 0.0 13.639 0.0 9 174.0 0.1920 0.0 17.014 3.266 Vet= 14.65 0.0 174.00 20.138 KFactor= 38.77 71 42.33 2.203 0.0 9.250 14.287 K Factor = 11.20 to 120.0 0.0 0.0 0.0 72 42.33 0.0141 0.0 9.250 0.130 Vet = 3.56 72 42.53 2.203 0.0 10.000 14.417 KFactor= 11.20 to 120.0 0.0 0.0 0.0 73 84.86 0.0509 0.0 10.000 0.509 Vet = 7.14 73 43.27 2.203 4E 27.277 17.860 14.926 K Factor= 11.20 to 120.0 T 13.639 40.916 0.0 34 128.13 0.1090 0.0 58.776 6.405 Vet = 10.78 0.0 128.13 21.331 KFactor= 27.74 74 42.33 2.203 0.0 9.250 14.285 K Factor = 11.20 to 120.0 0.0 0.0 0.0 75 42.33 0.0141 00 9.250 0.130 Vet = 3.56 75 42.53 2.203 0.0 10.000 14.415 KFactor= 11.20 to 120.0 0.0 0.0 0.0 76 84.86 0.0509 0.0 10.000 0.509 Vet = 7.14 76 43.26 2.203 4E 27.277 17.860 14.924 K Factor= 11.20 to 120.0 T 13.639 40.916 0.0 35 128.12 0.1090 0.0 58.776 6.404 Vet = 10.78 0.0 128.12 21.328 KFactor= 27.74 776 25.33 1.408 2T 13.233 102.250 20.001 to 120.0 0.0 13.233 0.0 277 25.33 0.0481 0.0 115.483 5.549 Vet = 5.22 0.0 25.33 25.550 KFactor= 5.01 8 379.85 4.26 2T 52.668 102.250 20.140 to 120.0 0.0 52.668 0.0 20 379.85 0.0328 0.0 154.918 5.080 Vet = 8.55 0.0 379.85 25.220 K Factor= 75.64 36 24.56 1.408 2T 13.233 119.730 21.344 to 120.0 0.0 13.233 0.0 39 24.56 0.0454 0.0 132.963 6.034 Vet = 5.06 0.0 24.56 27.378 K Factor= 4.69 10 23.13 1.408 2T 13.233 106.700 20.155 to 120.0 0.0 13.233 0.0 19 23.13 0.0406 0.0 119.933 4.872 Vet = 4.77 0.0 23.13 25.027 KFactor= 4.62 11 23.02 1.408 2T 13.233 106.700 20.176 to 120.0 0.0 13.233 0.0 18 23.02 0.0403 0.0 119.933 4.830 Vet = 4.74 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 12 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 23.02 25.006 K Factor= 4.60 12 22.97 1.408 2T 13.233 106.700 20.187 to 120.0 0.0 13.233 0.0 17 22.97 0.0401 0.0 119.933 4.808 Vel = 4.73 0.0 22.97 24.995 K Factor= 4.59 13 19.18 1.408 T 6.617 91.750 20.191 to 120.0 0.0 6.617 0.0 15 19.18 0.0287 0.0 98.367 2.826 Vel = 3.95 0.0 19.18 23.017 KFactor= 4.00 80 20.45 1.408 8E 26.466 149.500 21.329 to 120.0 2T 13.233 39.699 0.0 239 20.45 0.0323 0.0 189.199 6.119 Vel = 4.21 0.0 20.45 27.448 K Factor= 3.90 Al 24.55 1.408 21 13.233 119.600 21.348 to 120.0 0.0 13.233 0.0 A2 24.55 0.0454 0.0 132.833 6.026 Vel = 5.06 0.0 24.55 27.374 K Factor= 4.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 " A, ~rlh - - - - Fire Protection by Computer Design PARAMOUNT FIRE SYSTEMS, INC C-16 788204 Job Name : HOEHN Level 2-A PARTS Building : LEVEL 2 Location : 6800 AVENIDA ENCINAS System : 1-2-13 Contract Data File : HOEHN Level 2 Area 2 Auto Service REV 2 submittal.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PARAMOUNT FIRE SYSTEMS, INC Page HOEHN Level 2-A PARTS Date HYDRAULIC CALCULATIONS for Project name: HOEHN PORSCHE Location: 6800 AVENIDA ENCINAS Drawing no: LEVEL 2 Date: 8-17 Design Remote area number: L2-B Remote area location: LEVEL 2 AUTO SERVICE AREAS Occupancy classification: ORDINARY GROUP 2 Density: .20 - Gpm/SqFt Area of application: 1500- SqFt Coverage per sprinkler: 130- SqFt Type of sprinklers calculated: 5.6K SSU No. of sprinklers calculated: 15 In-rack demand: NA - GPM Hose streams: 250 - GPM Total water required (including hose streams): 667.1 - GPM @ 62.1 -Psi Type of system: WET GRID Volume of dry orpreaction system: NA - Gal Water supply information Date: 6-23-17 Location: 12" MAIN @6800 AVENIDA ENCINAS Source: CFD WATER AVAILABILITY FORM Name of contractor: PARAMOUNT FIRE SYSTEMS INC Address: 8069 WING AVENUE EL CAJON, CA Phone number: 619 562-6247 Name of designer: JAMES CHENEY Authority having jurisdiction: CARLSBAD FIRE PREVENTION BUREAU Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C PARAMOUNT FIRE SYSTEMS, INC Page 2 HOEHN Level 2-A PARTS Date City Water Supply: Demand: CI - Static Pressure : 100.8 Dl - Elevation : 11.391 C2 - Residual Pressure: 76.5 D2 - System Flow : 417.054 C2 - Residual Flow : 6425 D2 - System Pressure : 62.117 Hose (Demand) : 250 D3 - System Demand : 667.054 Safety Margin : 38.315 150 140 130 p120 DuO 1 E 100 S 90 S 80 - -_ u 70 D2 R60 E50 40 30 20 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PARAMOUNT FIRE SYSTEMS, INC Page 3 HOEHN Level 2-A PARTS Date Fitting Legend Abbrev. Name 1/2 % 1 114 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 1390 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 J 90Tee-BranchGry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390 Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD PARAMOUNT FIRE SYSTEMS, INC Page 4 HOEHN Level 2-A PARTS Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 77 23.0 5.6 30.38 na 30.87 0.2 130 7.0 78 23.0 5.6 30.38 na 30.87 0.2 130 7.0 79 23.0 30.88 na 80 23.0 33.92 na Ji 23.0 34.34 na 776 23.0 35.85 na 7 23.0 35.86 na 8 23.0 35.92 na 9 23.0 35.92 na 10 23.0 35.92 na 11 23.0 35.93 na 12 23.0 35.93 na 13 23.0 35.93 na 14 23.0 35.93 na 15 23.0 36.45 na 16 23.0 36.82 na 17 23.0 36.82 na 18 23.0 36.82 na 19 23.0 36.82 na 20 23.0 36.86 na 277 23.0 36.92 na 21 23.0 37.8 na TOR 23.0 38.28 na BOR 2.0 47.88 na UGI 2.0 48.24 na UG2 0.0 50.47 na UG3 0.0 59.49 na HYD 0.0 59.88 na 250.0 TEST -3.3 62.12 na 36 23.0 33.84 na Al 23.0 33.82 na 37 23.0 33.78 na 81 23.0 5.6 24.81 na 27.89 0.2 130 7.0 82 23.0 5.6 24.04 na 27.46 0.2 130 7.0 83 23.0 5.6 24.04 na 27.46 0.2 130 7.0 84 23.0 5.6 24.83 na 27.9 0.2 130 7.0 38 23.0 37.07 na A2 23.0 37.11 na 39 23.0 37.13 na 239 23.0 37.5 na 22 23.0 37.64 na 86 23.0 5.6 22.79 na 26.73 0.2 130 7.0 87 23.0 5.6 21.69 na 26.08 0.2 130 7.0 88 23.0 5.6 21.56 na 26.0 0.2 130 7.0 89 23.0 5.6 21.71 na 26.09 0.2 130 7.0 90 23.0 5.6 22.87 na 26.78 0.2 130 7.0 91 23.0 5.6 25.82 na 28.45 0.2 130 7.0 92 23.0 5.6 25.01 na 28.01 0.2 130 7.0 93 23.0 5.6 25.01 na 28.01 0.2 130 7.0 94 23.0 5.6 25.82 na 28.46 0.2 130 7.0 The maximum velocity is 13.68 and it occurs in the pipe between nodes 90 and 39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 5 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fithng Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 77 0.69 1.536 0.0 10.500 30.382 K Factor 5.60 to 120.0 0.0 0.0 0.0 78 0.69 0.0 0.0 10.500 0.0 Vel = 0.12 78 30.86 1.536 0.0 10.500 30.382 K Factor =5.60 to 120.0 0.0 0.0 0.0 79 31.55 0.0472 0.0 10.500 0.496 Vel = 5.46 79 0.0 1.536 T 10.108 54.250 30.878 to • 120.0 0.0 10.108 0.0 80 31.55 0.0472 0.0 64.358 3.039 Vel = 5.46 80 176.94 4.31 T 27.874 13.100 33.917 to 120.0 0.0 27.874 0.0 Ji 208.49 0.0102 0.0 40.974 0.419 Vel = 4.58 Ji 0.0 4.31 4J 89.197 59.330 34.336 to 120.0 0.0 89.197 0.0 776 208.49 0.0102 0.0 148.527 1.516 Vel = 4.58 776 -10.41 4.31 0.0 0.750 35.852 to 120.0 0.0 0.0 0.0 7 198.08 0.0093 0.0 0.750 0.007 Vel = 4.36 7 0.0 4.31 0.0 6.350 35.859 to 120.0 0.0 0.0 0.0 8 198.08 0.0093 0.0 6.350 0.059 Vel = 4.36 8 -155.80 4.31 0.0 1.916 35.918 to 120.0 0.0 0.0 0.0 9 42.28 0.0005 0.0 1.916 0.001 Vel = 0.93 9 0.0 4.31 0.0 5.916 35.919 to 120.0 0.0 0.0 0.0 10 42.28 0.0005 0.0 5.916 0.003 Vel = 0.93 10 -9.29 4.31 0.0 11.780 35.922 to 120.0 0.0 0.0 0.0 11 32.99 0.0003 0.0 11.780 0.004 Vel = 0.73 11 -9.25 4.31 0.0 10.980 35.926 to 120.0 0.0 0.0 0.0 12 23.74 0.0002 0.0 10.980 0.002 Vel = 0.52 12 -9.23 4.31 0.0 11.042 35.928 to 120.0 0.0 0.0 0.0 13 14.51 0.0001 0.0 11.042 0.001 Vel= 0.32 13 -7.70 4.31 2E 27.874 3.292 35.929 to 120.0 0.0 27.874 0.0 14 6.81 0.0 0.0 31.166 0.001 Vel = 0.15 14 0.0 1.408 3E 9.925 100.292 35.930 to 120.0 2T 13.233 23.158 0.0 15 6.81 0.0042 0.0 123.450 0.522 Vel = 1.40 15 7.70 1.408 T 6.617 14.666 36.452 to 120.0 0.0 6.617 0.0 16 14.51 0.0171 0.0 21.283 0.365 Vel = 2.99 16 0.0 4.31 0.0 12.000 36.817 to 120.0 0.0 0.0 0.0 17 14.51 0.0001 0.0 12.000 0.001 Vel = 0.32 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC HOEHN Level 2-A PARTS Hyd. Qa Dia. Fitting Ref. "C" or Point Qt Pf/Ft Eqv. Ln Page 6 Date Pipe Pt Pt Ftng's Pe Pv ******* Notes Total Pf Pn 17 9.23 4.31 0.0 11.000 36.818 to 120.0 0.0 0.0 0.0 18 23.74 0.0002 0.0 11.000 0.002 Vel = 0.52 18 9.25 4.31 0.0 11.780 36.820 to 120.0 0.0 0.0 0.0 19 32.99 0.0003 0.0 11.780 0.004 VeI= 0.73 19 9.29 4.31 2E 27.874 11.000 36.824 to 120.0 T 27.874 55.748 0.0 20 42.28 0.0005 0.0 66.748 0.035 Vel = 0.93 20 155.80 4.26 0.0 6.416 36.859 to 120.0 0.0 0.0 0.0 277 198.08 0.0098 0.0 6.416 0.063 Vel = 4.46 277 10.41 4.26 T 26.334 55.125 36.922 to 120.0 0.0 26.334 0.0 21 208.49 0.0108 0.0 81.459 0.881 Vel = 4.69 21 208.56 6.357 3E 52.808 33.542 37.803 to 120.0 0.0 52.808 0.0 TOR 417.05 0.0055 0.0 86.350 0.479 Vel = 4.22 TOR 0.0 6.357 E 17.603 21.000 38.282 to 120.0 B 12.573 70.411 9.095 BOR 417.05 0.0055 S 40.235 91.411 0.507 Vel= 4.22 BOR 0.0 6.357 E 17.603 9.000 47.884 to 120.0 T 37.72 55.323 0.0 UG1 417.05 0.0056 0.0 64.323 0.357 Vel = 4.22 UG1 0.0 6.09 7E 151.081 150.000 48.241 to 150.0 0.0 151.080 0.866 UG2 417.05 0.0045 0.0 301.080 1.363 Vel = 4.59 UG2 0.0 6.09 0.0 5.000 50.470 to 150.0 0.0 0.0 9.000 * * Fixed Loss = 9 UG3 417.05 0.0044 0.0 5.000 0.022 Vel = 4.59 UG3 0.0 6.16 E 20.084 16.000 59.492 to 140.0 T 43.037 63.121 0.0 HYD 417.05 0.0049 0.0 79.121 0.385 Vel = 4.49 HYD 250.00 6.16 E 20.084 2.500 59.877 Qa = 250 to 140.0 G 4.304 67.425 1.429 TEST 667.05 0.0116 T 43.037 69.925 0.811 Vel = 7.18 0.0 667.05 62.117 KFactor= 84.64 80 -176.93 4.31 0.0 10.500 33.917 to 120.0 0.0 0.0 0.0 36 -176.93 -0.0075 0.0 10.500 -0.079 Vel = 3.89 36 65.31 4.31 0.0 5.833 33.838 to 120.0 0.0 0.0 0.0 Al -111.62 -0.0031 0.0 5.833 -0.018 VeI= 2.45 Al 56.41 4.31 2E 27.874 12.250 33.820 to 120.0 0.0 27.874 0.0 37 -55.21 -0.0009 0.0 40.124 -0.036 Vel = 1.21 37 0.0 1.408 E 3.308 34.250 33.784 to 120.0 1 6.617 9.925 0.0 81 -55.21 -0.2031 0.0 44.175 -8.972 VeI= 11.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 7 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 81 27.89 1.408 0.0 14.000 24.812 K Factor =5.60 to 120.0 0.0 0.0 0.0 82 -27.32 -0.0553 0.0 14.000 -0.774 Vel = 5.63 82 27.46 1.408 0.0 14.000 24.038 K Factor 5.60 to 120.0 0.0 0.0 0.0 83 0.14 0.0 0.0 14.000 0.0 Vel = 0.03 83 27.45 1.408 0.0 14.000 24.038 K Factor =5.60 to 120.0 0.0 0.0 0.0 84 27.59 0.0563 0.0 14.000 0.788 Vel = 5.69 84 27.90 1.408 E 3.308 49.800 24.826 K Factor = 5.60 to 120.0 T 6.617 9.925 0.0 38 55.49 0.2050 0.0 59.725 12.245 Vel = 11.43 38 0.0 4.31 2E 27.874 12.250 37.071 to 120.0 0.0 27.874 0.0 A2 55.49 0.0009 0.0 40.124 0.035 Vel = 1.22 A2 56.51 4.31 0.0 6.042 37.106 to 120.0 0.0 0.0 0.0 39 112.0 0.0033 0.0 6.042 0.020 Vel = 2.46 39 66.39 4.31 2E 27.874 20.584 37.126 to 120.0 0.0 27.874 0.0 239 178.39 0.0077 0.0 48.458 0.371 Vel = 3.92 239 30.18 4.31 0.0 14.250 37.497 to 120.0 0.0 0.0 0.0 22 208.57 0.0102 0.0 14.250 0.145 Vel = 4.59 22 0.0 6.357 4E 70.411 33.790 37.642 to 120.0 0.0 70.411 0.0 21 208.57 0.0015 0.0 104.201 0.161 Vel= 2.11 0.0 208.57 37.803 K Factor= 33.92 776 10.41 1.408 2T 13.233 102.250 35.852 to 120.0 0.0 13.233 0.0 277 10.41 0.0093 0.0 115.483 1.070 Vel = 2.15 0.0 10.41 36.922 KFactor= 1.71 8 155.80 4.31 2T 55.748 102.250 35.918 to 120.0 0.0 55.748 0.0 20 155.8 0.0060 0.0 157.998 0.941 Vel = 3.43 0.0 155.80 36.859 KFactor= 25.66 36 -65.31 1.408 T 6.617 33.250 33.838 to 120.0 0.0 6.617 0.0 86 -65.31 -0.2771 0.0 39.867 -11.047 Vel = 13.46 86 26.74 1.408 0.0 10.500 22.791 K Factor =5.60 to 120.0 0.0 0.0 0.0 87 -38.57 -0.1047 0.0 10.500 -1.099 Vel = 7.95 87 26.08 1.408 0.0 10.500 21.692 K Factor =5.60 to 120.0 0.0 0.0 0.0 88 -12.49 -0.0130 0.0 10.500 -0.136 Vel = 2.57 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 8 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 88 26.00 1.408 0.0 10.500 21.556 K Factor =5.60 to 120.0 0.0 0.0 0.0 89 13.51 0.0150 0.0 10.500 0.158 Vel = 2.78 89 26.09 1.408 0.0 10.500 21.714 K Factor =5.60 to 120.0 0.0 0.0 0.0 90 39.6 0.1098 0.0 10.500 1.153 Vel = 8.16 90 26.78 1.408 E 3.308 40.000 22.867 K Factor = 5.60 to 120.0 T 6.617 9.925 0.0 39 66.38 0.2856 0.0 49.925 14.259 Vel = 13.68 0.0 66.38 37.126 KFactor= 10.89 Al -56.41 1.408 T 6.617 31.250 33.820 to 120.0 0.0 6.617 0.0 91 -56.41 -0.2113 0.0 37.867 -8.003 Vel = 11.62 91 28.45 1.408 0.0 14.000 25.817 K Factor =5.60 to 120.0 0.0 0.0 0.0 92 -27.96 -0.0576 0.0 14.000 -0.807 Vel = 5.76 92 28.01 1.408 0.0 14.000 25.010 K Factor =5.60 to 120.0 0.0 0.0 0.0 93 0.05 0.0 0.0 14.000 0.0 Vel = 0.01 93 28.00 1.408 0.0 14.000 25.010 K Factor =5.60 to 120.0 0.0 0.0 0.0 94 28.05 0.0580 0.0 14.000 0.812 Vel = 5.78 94 28.46 1.408 T 6.617 46.600 25.822 K Factor =5.60 to 120.0 0.0 6.617 0.0 A2 56.51 0.2120 0.0 53.217 11.284 VeI= 11.64 0.0 56.51 37.106 KFactor= 9.28 10 9.29 1.408 2T 13.233 106.700 35.922 to 120.0 0.0 13.233 0.0 19 9.29 0.0075 0.0 119.933 0.902 Vel = 1.91 0.0 9.29 36.824 K Factor = 1.53 11 9.25 1.408 2T 13.233 106.700 35.926 to 120.0 0.0 13.233 0.0 18 9.25 0.0075 0.0 119.933 0.894 Vel = 1.91 0.0 9.25 36.820 K Factor= 1.52 12 9.23 1.408 2T 13.233 106.700 35.928 to 120.0 0.0 13.233 0.0 17 9.23 0.0074 0.0 119.933 0.890 VeI= 1.90 0.0 9.23 36.818 KFactor= 1.52 13 7.70 1.408 T 6.617 91.750 35.929 to 120.0 0.0 6.617 0.0 15 7.7 0.0053 0.0 98.367 0.523 Vel = 1.59 0.0 7.70 36.452 K Factor= 1.28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 9 HOEHN Level 2-A PARTS Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 77 30.18 1.408 8E 26.466 74.000 30.382 to 120.0 T 6.617 33.083 0.0 239 30.18 0.0664 0.0 107.083 7.115 VeI = 6.22 0.0 30.18 37.497 K Factor= 4.93 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - Fire Protection by Computer Design PARAMOUNT FIRE SYSTEMS, INC C-16 788204 Job Name : HOEHN LEVEL 3 AREA A PARKING GARAGE Building : LEVEL 3 Location : 6800 AVENIDA ENCINAS System : 1-3-A Contract Data File : HOEHN Level 3 Area I .WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PARAMOUNT FIRE SYSTEMS, INC Page HOEHN LEVEL 3 AREA A PARKING GARAGE Date HYDRAULIC CALCULATIONS for Project name: HOEHN PORSCHE Location: 6800 AVENIDA ENCINAS Drawing no: LEVEL 3 Date: 8-17 Design Remote area number: 1-3-A Remote area location: LEVEL 3 INVENTORY PARKING GARAGE Occupancy classification: ORDINARY GROUP 1 Density: .15 - Gpm/SqFt Area of application: 1500 - SqFt Coverage per sprinkler: 130- SqFt Type of sprinklers calculated: 5.6K SSU No. of sprinklers calculated: 16 In-rack demand: NA - GPM Hose streams: 250 - GPM Total water required (including hose streams): 682.8 -GPM @ 91.5 - Psi Type of system: WET LOOP / TREE Volume of dry orpreaction system: NA - Gal Water supply information Date: 6-23-17 Location: 12 MAIN @6800 AVENIDA ENCINAS Source: CFD WATER AVAILABILITY FORM Name of contractor: PARAMOUNT FIRE SYSTEMS INC Address: 8069 WING AVENUE EL CAJON, CA Phone number: 619 562-6247 Name of designer: JAMES CHENEY Authority having jurisdiction: CARLSBAD FIRE PREVENTION BUREAU Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C.) -J UI 0 m m c cn cn m - F) C.) A (7' 0 J W CO - - - - - - 0000000000 N) C.) A U' 000000 iii±iiiiii N.) -. - -. CD - CD 0 -4(0-.) C, 0 3 V C CD -U (a 3 to ty CD C) C) 0 C -S CL CD 3 2: C Cl, 0 C) 0 CD -.1 (a 0 r11Z a. C " o - C — 0 C 0 m C) M CL CD CD 5 0•0 . 5• -' r'< CD —(0 VCD — 0) CO CD . ?. -" U) (Dc aw a. -' CD CD -' CL 0 -, 5. () — -Th CL U) U)CD )(0 CD U) a =r 0) CL CD a. a 0) -, a - 0) CD CO . - £?. -CD o CD 3 0) 0 C) CD §R R E V CD = CD -I Q) CL _.• *0) Cl) -I' CD .-.. - U -CD * m . CD 44. C, CL C)-.. -'< CD -' a 0) o Zo 0-h 11 =r V C 0 C) CD a CL C) .(0 U) .0 C C) - 5• U) 0 ucm5. CD C) C C) CD U) V0 Cfl•o C -' CD —c C) C.) 0000 - 0 0000 r%) 0 0 CD - CD Is) - OCD-".l MW 0)0) CD Is) 0)1..) Is) 00)00 -4- -4 CDM.JC.30 — CDC.) CD CD 4MCD.0.0 -. co CA 0 - CDC.)OCD - C0C.)-(l)0 O 0)0)sQ - --0)0 Is) - 0 0 -u 0)0) — CO CD CD C..) Pressure I Flow Summary - STANDARD PARAMOUNT FIRE SYSTEMS, INC Page 4 HOEHN LEVEL 3 AREA A PARKING GARAGE Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 32.83 5.6 14.43 na 21.28 0.15 130 12.12 2 32.83 5.6 14.64 na 21.43 0.15 130 12.12 3 32.83 5.6 16.76 na 22.93 0.15 130 12.12 4 32.83 5.6 19.56 na 24.77 0.15 130 12.12 5 32.83 5.6 25.63 na 28.35 0.15 130 12.12 6 32.83 5.6 35.68 na 33.45 0.15 130 12.12 7 32.83 47.69 na 8 31.33 54.6 na 9 31.33 57.5 na TOR 31.33 59.98 na BOR 2.0 77.04 na UG1 2.0 77.42 na UG2 0.0 79.74 na UG3 0.0 88.77 na HYD 0.0 89.18 na 250.0 TEST -3.3 91.46 na 16 32.83 5.6 12.13 na 19.5 0.15 130 12.12 17 32.83 5.6 12.3 na 19.64 0.15 130 12.12 18 32.83 5.6 13.89 na 20.87 0.15 130 12.12 19 32.83 5.6 16.26 na 22.58 0.15 130 12.12 20 32.83 5.6 27.92 na 29.59 0.15 130 12.12 21 32.83 5.6 36.96 na 34.05 0.15 130 12.12 22 32.83 48.12 na 23 31.33 54.58 na 24 32.83 5.6 33.14 na 32.24 0.15 130 12.12 25 32.83 5.6 33.79 na 32.55 0.15 130 12.12 26 32.83 5.6 36.16 na 33.67 0.15 130 12.12 27 32.83 5.6 41.29 na 35.98 0.15 130 12.12 28 32.83 48.91 na 29 31.33 54.53 na 30 31.33 54.58 na 31 31.33 54.85 na The maximum velocity is 24.47 and it occurs in the pipe between nodes 5 and 6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 5 HOEHN LEVEL 3 AREA A PARKING GARAGE Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 21.28 1.408 0.0 6.010 14.434 K Factor =5.60 to 120.0 0.0 0.0 0.0 2 21.28 0.0348 0.0 6.010 0.209 Vet = 4.38 2 21.42 1.408 2E 6.617 10.166 14.643 K Factor 5.60 to 120.0 0.0 6.617 0.0 3 42.7 0.1263 0.0 16.783 2.119 Vet = 8.80 3 22.93 1.408 0.0 10.000 16.762 K Factor =5.60 to 120.0 0.0 0.0 0.0 4 65.63 0.2797 0.0 10.000 2.797 Vet = 13.52 4 24.77 1.408 0.0 12.000 19.559 K Factor =5.60 to 120.0 0.0 0.0 0.0 5 90.4 0.5057 0.0 12.000 6.068 Vet = 18.63 5 28.35 1.408 0.0 12.000 25.627 K Factor =5.60 to 120.0 0.0 0.0 0.0 6 118.75 0.8375 0.0 12.000 10.050 Vel = 24.47 6 33.45 1.639 E 4.363 14.625 35.677 K Factor =5.60 to 120.0 0.0 4.363 0.0 7 152.2 0.6326 0.0 18.988 12.011 Vet = 23.14 7 0.0 1.639 T 8.727 1.166 47.688 to 120.0 0.0 8.727 0.650 8 152.2 0.6326 0.0 9.893 6.258 Vet = 23.14 8 83.12 4.31 I 9.756 128.250 54.596 to 120.0 4J 89.197 98.953 0.0 9 235.32 0.0128 .0.0 227.203 2.902 Vet = 5.17 9 197.56 4.31 I 9.756 30.750 57.498 to 120.0 J 22.299 32.055 0.0 TOR 432.88 0.0395 0.0 62.805 2.478 Vet = 9.52 TOR 0.0 4.26 I 9.217 29.330 59.976 to 120.0 J 21.067 75.052 12.703 BOR 432.88 0.0418 B 15.8 104.382 4.358 Vet = 9.74 S 28.968 BOR 0.0 6.357 E 17.603 9.000 77.037 to 120.0 T 37.72 55.323 0.0 UGI 432.88 0.0059 0.0 64.323 0.382 Vet = 4.38 UGI 0.0 6.09 7E 151.081 150.000 77.419 to 150.0 0.0 151.080 0.866 UG2 432.88 0.0048 0.0 301.080 1.460 Vet = 4.77 UG2 0.0 6.09 0.0 5.000 79.745 to 150.0 0.0 0.0 9.000 * * Fixed Loss = 9 UG3 432.88 0.0048 0.0 5.000 0.024 Vet = 4.77 UG3 0.0 6.16 E 20.084 16.000 88.769 to 140.0 T 43.037 63.121 0.0 HYD 432.88 0.0052 0.0 79.121 0.412 Vet = 4.66 HYD 250.00 6.16 E 20.084 2.500 89.181 Qa = 250 to 140.0 G 4.304 67.425 1.429 TEST 682.88 0.0121 T 43.037 69.925 0.847 Vel = 7.35 0.0 682.88 91.457 KFactor= 71.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 6 HOEHN LEVEL 3 AREA A PARKING GARAGE Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 16 19.50 1.408 0.0 6.000 12.125 K Factor =5.60 to 120.0 0.0 0.0 0.0 17 19.5 0.0297 0.0 6.000 0.178 Vel = 4.02 17 19.64 1.408 2E 6.617 8.166 12.303 K Factor 5.60 to 120.0 0.0 6.617 0.0 18 39.14 0.1075 0.0 14.783 1.589 Vel = 8.07 18 20.87 1.408 0.0 10.000 13.892 K Factor =5.60 to 120.0 0.0 0.0 0.0 19 60.01 0.2370 0.0 10.000 2.370 Vel = 12.37 19 22.59 1.408 4E 13.233 14.000 16.262 K Factor 5.60 to 120.0 0.0 13.233 0.0 20 82.6 0.4279 0.0 27.233 11.653 VeI= 17.02 20 29.58 1.408 0.0 12.000 27.915 K Factor =5.60 to 120.0 0.0 0.0 0.0 21 112.18 0.7539 0.0 12.000 9.047 Vel = 23.12 21 34.05 1.639 E 4.363 14.625 36.962 K Factor =5.60 to 120.0 0.0 4.363 0.0 22 146.23 0.5875 0.0 18.988 11.155 VeI= 22.24 22 0.0 1.639 T 8.727 1.166 48.117 to 120.0 0.0 8.727 0.650 23 146.23 0.5874 0.0 9.893 5.811 Vel = 22.24 23 -63.11 4.31 0.0 9.440 54.578 to 120.0 0.0 0.0 0.0 8 83.12 0.0019 0.0 9.440 0.018 Vel = 1.83 0.0 83.12 54.596 KFactor= 11.25 24 32.24 1.408 0.0 8.660 33.143 K Factor =5.60 to 120.0 0.0 0.0 0.0 25 32.24 0.0751 0.0 8.660 0.650 Vel = 6.64 25 32.55 1.408 0.0 8.660 33.793 K Factor = 5.60 to 120.0 0.0 0.0 0.0 26 64.79 0.2731 0.0 8.660 2.365 Vel = 13.35 26 33.68 1.408 0.0 8.660 36.158 K Factor =5.60 to 120.0 0.0 0.0 0.0 27 98.47 0.5923 0.0 8.660 5.129 Vel = 20.29 27 35.98 1.639 E 4.363 10.792 41.287 K Factor =5.60 to 120.0 0.0 4.363 0.0 28 134.45 0.5029 0.0 15.155 7.621 Vel = 20.45 28 0.0 1.639 T 8.727 1.166 48.908 to 120.0 0.0 8.727 0.650 29 134.45 0.5029 0.0 9.893 4.975 Vel = 20.45 29 0.0 4.31 0.0 10.333 54.533 to 120.0 0.0 0.0 0.0 30 134.45 0.0045 0.0 10.333 0.047 Vel = 2.96 30 63.11 4.31 J 22.299 6.542 54.580 to 120.0 0.0 22.299 0.0 31 197.56 0.0093 0.0 28.841 0.267 Vel = 4.34 31 0.0 4.31 21 19.512 222.750 54.847 to 120.0 2J 44.598 64.110 0.0 9 197.56 0.0092 0.0 286.860 2.651 Vel = 4.34 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 7 HOEHN LEVEL 3 AREA A PARKING GARAGE Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 197.56 57.498 K Factor= 26.05 23 63.11 4.31 0.0 1.792 54.578 to 120.0 0.0 0.0 0.0 30 63.11 0.0011 0.0 1.792 0.002 Vel= 1.39 0.0 63.11 54.580 KFactor= 8.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - Fire Protection by Computer Design PARAMOUNT FIRE SYSTEMS, INC C-16 788204 Job Name : HOEHN Level 3-13 PARKING GARAGE Building : LEVEL 3 Location : 6800 AVENIDA ENCINAS System : 1-3-13 Contract Data File : HOEHN Level 3 Area 2.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PARAMOUNT FIRE SYSTEMS, INC Page HOEHN Level 3-B PARKING GARAGE Date HYDRAULIC CALCULATIONS for Project name: HOEHN PORSCHE Location: 6800 AVENIDA ENCINAS Drawing no: LEVEL 3 Date: 8-17 Design Remote area number: L3-B Remote area location: LEVEL 3 INVENTORY PARKING GARAGE Occupancy classification: ORDINARY GROUP I Density: .15 - Gpm/SqFt Area of application: 1500 - SqFt Coverage per sprinkler: 130 - Sq Ft Type of sprinklers calculated: 5.6K SSU No. of sprinklers calculated: 13 In-rack demand: NA - GPM Hose streams: 250 - GPM Total water required (including hose streams): 551.5 - GPM @ 70.1 -Psi Type of system: WET LOOP I TREE Volume of thy or preaction system: NA - Gal Water supply information Date: 6-23-17 Location: 12" MAIN @ 6800 AVENIDA ENCINAS Source: CFD WATER AVAILABILITY FORM Name of contractor: PARAMOUNT FIRE SYSTEMS INC Address: 8069 WING AVENUE EL CAJON, CA Phone number: 619 562-6247 Name of designer: JAMES CHENEY Authority having jurisdiction: CARLSBAD FIRE PREVENTION BUREAU Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C PARAMOUNT FIRE SYSTEMS, INC Page 2 HOEHN Level 3-13 PARKING GARAGE Date City Water Supply: Demand: CI - Static F5ressure : 100.8 Dl - Elevation : 15.648 C2 - Residual Pressure: 76.5 D2 - System Flow : 301.54 C2 - Residual Flow : 6425 D2 - System Pressure : 70.094 Hose (Demand) : 250 D3 - System Demand : 551.54 Safety Margin : 30.448 150 140 130 p120 R11° E 100 S 90 - --------. S 80 D2 u 70 R 60 D[ E5° 40 30 20 Dl 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary PARAMOUNT FIRE SYSTEMS, INC Page 3 HOEHN Level 3-B PARKING GARAGE Date Fitting Legend Abbrev. Name 1/2 % 1 1% 11/2 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 5 8 7 8.5 10 13 17 20 23 25 33 36 40 J 90'Tee-Branch Gry Vic #20 0 0 4.5 6 8 8.5 10.8 13 17 16 21 25 33 41 50 65 78 88 98 120 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90' Flowthru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD PARAMOUNT FIRE SYSTEMS, INC Page 4 HOEHN Level 3-13 PARKING GARAGE Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 32 32.83 5.6 12.13 na 19.5 0.15 130 12.1 33 32.83 5.6 12.36 na 19.69 0.15 130 12.1 34 32.83 5.6 13.22 na 20.36 0.15 130 12.1 35 32.83 5.6 15.11 na 21.77 0.15 130 12.1 36 32.83 5.6 18.85 na 24.32 0.15 130 12.1 37 32.83 5.6 24.92 na 27.96 0.15 130 12.1 38 32.83 30.21 na 39 31.33 39.32 na 40 31.33 39.38 na 41 31.33 39.58 na 31 31.33 39.85 na 30 31.33 39.97 na 23 31.33 39.98 na 8 31.33 40.01 na 9 31.33 40.86 na TOR 31.33 42.13 na BOR 2.0 57.06 na UGI 2.0 57.26 na UG2 0.0 58.87 na UG3 0.0 67.88 na HYD 0.0 68.09 na 250.0 TEST -3.3 70.09 na 42 32.83 5.6 12.14 na 19.52 0.15 130 12.1 43 32.83 5.6 12.38 na 19.71 0.15 130 12.1 44 32.83 5.6 13.25 na 20.38 0.15 130 12.1 45 32.83 5.6 15.14 na 21.79 0.15 130 12.1 46 32.83 5.6 18.88 na 24.33 0.15 130 12.1 47 32.83 5.6 24.96 na 27.98 0.15 130 12.1 48 32.83 30.26 na 49 32.83 5.6 37.39 na 34.24 0.15 130 12.1 50 32.83 38.28 na 51 31.33 39.61 na The maximum velocity is 27.55 and it occurs in the pipe between nodes 47 and 48 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 5 HOEHN Level 3-13 PARKING GARAGE Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 32 19.50 1.408 0.0 8.000 12.125 K Factor 5.60 to 120.0 0.0 0.0 0.0 33 19.5 0.0296 0.0 8.000 0.237 Vel = 4.02 33 19.69 1.408 0.0 8.000 12.362 K Factor 5.60 to 120.0 0.0 0.0 0.0 34 39.19 0.1078 0.0 8.000 0.862 Vel = 8.08 34 20.36 1.408 0.0 8.080 13.224 K Factor = 5.60 to 120.0 0.0 0.0 0.0 35 59.55 0.2337 0.0 8.080 1.888 Vel = 12.27 35 21.77 1.408 0.0 9.000 15.112 K Factor =5.60 to 120.0 0.0 0.0 0.0 36 81.32 0.4158 0.0 9.000 3.742 Vel = 16.76 36 24.32 1.408 0.0 9.000 18.854 K Factor =5.60 to 120.0 0.0 0.0 0.0 37 105.64 0.6746 0.0 9.000 6.071 Vel = 21.77 37 27.96 1.408 E 3.308 1.770 24.925 K Factor =5.60 to 120.0 0.0 3.308 0.0 38 133.6 1.0416 0.0 5.078 5.289 Vel = 27.53 38 0.0 1.408 T 6.617 1.500 30.214 to 120.0 0.0 6.617 0.650 39 133.6 1.0415 0.0 8.117 8.454 Vel = 27.53 39 0.0 4.31 0.0 13.000 39.318 to 120.0 0.0 0.0 0.0 40 133.6 0.0045 0.0 13.000 0.058 Vel = 2.94 40 133.70 4.31 0.0 12.750 39.376 to 120.0 0.0 0.0 0.0 41 267.3 0.0162 0.0 12.750 0.206 Vel = 5.88 41 -146.57 4.31 T 27.874 43.020 39.582 to 120.0 0.0 27.874 0.0 31 120.73 0.0037 0.0 70.894 0.264 Vel = 2.65 31 0.0 4.31 T 27.874 5.460 39.846 to 120.0 0.0 27.874 0.0 30 120.73 0.0037 0.0 33.334 0.124 Vel = 2.65 30 0.0 4.31 0.0 1.792 39.970 to 120.0 0.0 0.0 0.0 23 120.73 0.0033 0.0 1.792 0.006 Vel = 2.65 23 0.0 4.31 0.0 9.440 39.976 to 120.0 0.0 0.0 0.0 8 120.73 0.0038 0.0 9.440 0.036 Vel = 2.65 8 0.0 4.31 I 9.756 128.250 40.012 to 120.0 4J 89.197 98.953 0.0 9 120.73 0.0037 0.0 227.203 0.844 Vel = 2.65 9 180.81 4.31 I 9.756 30.750 40.856 to 120.0 J 22.299 32.055 0.0 TOR 301.54 0.0202 0.0 62.805 1.269 Vel = 6.63 TOR 0.0 4.26 I 9.217 29.330 42.125 to 120.0 J 21.067 75.052 12.703 BOR 301.54 0.0214 B 15.8 104.382 2.233 Vel = 6.79 S 28.968 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 6 HOEHN Level 3-B PARKING GARAGE Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. tic"or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 0.0 6.357 E 17.603 9.000 57.061 to 120.0 T 37.72 55.323 0.0 UGI 301.54 0.0030 0.0 64.323 0.196 Vel = 3.05 UGI 0.0 6.09 7E 151.081 150.000 57.257 to 150.0 0.0 151.080 0.866 UG2 301.54 0.0025 0.0 301.080 0.747 Vel = 3.32 UG2 0.0 6.09 0.0 5.000 58.870 to 150.0 0.0 0.0 9.000 * * Fixed Loss = 9 UG3 301.54 0.0026 0.0 5.000 0.013 Vel = 3.32 UG3 0.0 6.16 E 20.084 16.000 67.883 to 140.0 T 43.037 63.121 0.0 HYD 301.54 0.0027 0.0 79.121 0.211 Vel = 3.25 HYD 250.00 6.16 E 20.084 2.500 68.094 Qa = 250 to 140.0 G 4.304 67.425 1.429 TEST 551.54 0.0082 T 43.037 69.925 0.571 Vel = 5.94 0.0 551.54 70.094 KFactor= 65.88 42 19.52 1.408 0.0 8.000 12.145 K Factor =5.60 to 120.0 0.0 0.0 0.0 43 19.52 0.0296 0.0 8.000 0.237 Vel = 4.02 43 19.70 1.408 0.0 8.000 12.382 K Factor =5.60 to 120.0 0.0 0.0 0.0 44 39.22 0.1079 0.0 8.000 0.863 Vel = 8.08 44 20.38 1.408 0.0 8.080 13.245 K Factor =5.60 to 120.0 0.0 0.0 0.0 45 59.6 0.2340 0.0 8.080 1.891 Vel = 12.28 45 21.79 1.408 0.0 9.000 15.136 K Factor =5.60 to 120.0 0.0 0.0 0.0 46 81.39 0.4163 0.0 9.000 3.747 Vel = 16.77 46 24.33 1.408 0.0 9.000 18.883 K Factor =5.60 to 120.0 0.0 0.0 0.0 47 105.72 0.6756 0.0 9.000 6.080 Vel = 21.78 47 27.98 1.408 E 3.308 1.770 24.963 K Factor = 5.60 to 120.0 0.0 3.308 0.0 48 133.7 1.0431 0.0 5.078 5.297 Vel = 27.55 48 0.0 1.408 1 6.617 1.500 30.260 to 120.0 0.0 6.617 0.650 40 133.7 1.0430 0.0 8.117 8.466 VeI= 27.55 0.0 133.70 39.376 K Factor = 21.31 49 34.24 1.408 T 6.617 3.980 37.386 K Factor =5.60 to 120.0 0.0 6.617 0.0 50 34.24 0.0840 0.0 10.597 0.890 Vel = 7.06 50 0.0 1.408 T 6.617 1.500 38.276 to 120.0 0.0 6.617 0.650 51 34.24 0.0838 0.0 8.117 0.680 Vel = 7.06 51 146.57 4.31 J 22.299 136.980 39.606 to 120.0 0.0 22.299 0.0 9 180.81 0.0078 0.0 159.279 1.250 Vel = 3.98 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams PARAMOUNT FIRE SYSTEMS, INC Page 7 HOEHN Level 3-13 PARKING GARAGE Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 180.81 40.856 KFactor= 28.29 41 146.57 4.31 0.0 4.500 39.582 to 120.0 0.0 0.0 0.0 51 146.57 0.0053 0.0 4.500 0.024 Vel = 3.22 0.0 146.57 39.606 K Factor= 23.29 Computer Programs by Hydratec Inc. Route 111 Wndham N.H. USA 03087 o L.L!' CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Hoehn Porsche SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 6800 Avenida Encinas CITY: Carlsbad PHONE: ( 619 ) 572-1407 (Paramount Fire Systems, Inc.) FAX NUMBER: Largest Building (ft.2): Sprinkled? V Construction Type:__________________ SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Avendia Encinas TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 112 PSI Hydrant Number (if applicable): H61941 Elevation of test: 60 Feet Date/Time of Test': - Pitotlube Reading: PSI corresponding Flow: GPM Total Flow: 6,425 GPM [Residual Pressure 85 PSI tpeakdemand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this exceeds the District's criteria of no more than 10 fps in pipelines. Therefore, the maximum allowable ire flow based on District criteria is 6,425 pm. 1Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: . I have witnessed and/or reviewed this water flow information and by personal knowledge and/or on-site observation certify that the above information is correct. Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature:________________________________________ Title/Org: P(ie'ctManager Date: 06/23/2017 - CAMTO ROSA I Hydrant I \ H61941 dill , L__i 1NN MmAZUL ______ 2 11 12 / 12 _ HHHuw SKYSA AV / Project / Site CDII I Ir v. a Legend I w_Hydrant Pipe ZONE -318 OAV Hoehn Porsche - Fire Flow Analysis (Maxim 30011F) Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative MaximTM Series M300 (Maxim 300), M300N (Maxim 300N) Reduced Pressure Detector Assemblies Sizes: 21/211 -10" (65-250mm) II.nn nv It is illegal to use this product in any plumbing system providing water for human consumption, such as dnking or dishwashing, in the United States. Before installing standard material prod- uct, consult your local water authority, building and plumbing codes. The Maxim M300, M300N Double Check Detector Assemblies are designed to pro- tect drinking water supplies from dangerous cross-connections in accordance with national plumbing codes and water authority requirements for non-health hazard non-potable service applications such as irrigation, fire line, or industrial processing. The Maxim M300, M300N may be installed under continuous pressure service and may be subjected to backpressure. The Maxim M300, M300N are used primarily on fire line sprinkler systems when it is necessary to monitor unauthorized use of water. Specifications The Double Check Detector Assemblies shall consist of two independent Tr-Link Check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Tr-Link Checks shall be removable and serviceable, without the use of special tools. The housing shall be constructed of 304 (Schedule 40) stainless steel pipe with groove end connections. Tr-Link Checks shall have reversible elastomer discs and in operation shall produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. The bypass assembly consists of a meter registering either gallon or cubic measurements, a double check valve assembly and required test cocks. Assembly shall be a Maxim M300, M300N as manufactured by the Ames Company. LNOTICE The information contained herein is not intended to replace the full product instal- lation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and prod- uct safety information before beginning the installation of this product. All I A M E S Features Extremely Compact Design 70% Lighter than Traditional Designs 304 (Schedule 40) Stainless Steel Housing & Sleeve Groove Fittings Allow Integral Pipeline Adjustment Patented Tr-Link Check Provides Lowest Pressure Loss Unmatched Ease of Serviceability Available with Grooved Butterfly Valve Shutoffs Available for Horizontal, Vertical or N Pattern Installations Replaceable Check Disc Rubber Pines Are &Waterwotks product specillcaons in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Noes Are &Wateiwoiks Technical Service. Ames Are &Waterwods reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Are &Waterwodcs products previously or subsequently sold. FIRE & WATERWORKS A WAITS Brand Configurations Horizontal Vertical up "N" pattern horizontal Materials Housing & Sleeve: 304 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna 'N' Tr-Link Checks: Noryl®, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 300 Series Stainless Steel Springs: Stainless Steel Dimensions - Weights Available Models OSY - UL/FM flanged outside stem and yoke resilient seated gate valves BFG - ULJFM grooved gear operated butterfly valves w/tamper switch *Q( FxG - Flanged inlet gate connection and grooved outlet gate connection *5\I GxF - Grooved inlet gate connection and flanged outlet gate connection *05 GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory" *Consult factory for dimensions Pressure - Temperature Temperature Range: 33°F - 110°F (5°C - 43°C) Maximum Working Pressure: 175ps1 (12.06 bar) _____________ A -i M300, M300N !11lIliI ,ilni3miilin$ WEIGHT in mm A in mm C (OSY) in mm 0 in mm 6 in mm H in mm I in mm J in mm P in mm M300 lbs kgs M300N lbs. kgs. 21h 65 30/4 781 16/8 416 3'I2 89 291/16 738 211/2 546 151Il6 402 81 /l6 223 13/16 335 139 63 147 67 3 80 31I4 806 18I8 479 311/16 94 301/2 775 221/4 565 171/8 435 93ho 233 141/2 368 159 72 172 78 4 100 401/2 1029 1 22/4 578 1 5 127 1 393/4 1010 1 301/4 768 1 20I8 518 1 1111/16 297 1 15/ie 386 1 233 106 1 256 116 6 150 473/4 1213 301/8 765 61/2 165 40 1016 371/2 953 24/4 629 14/16 360 191/2 495 404 183 444 201 8 200 543/4 1391 373/4 959 71/2 191 591/8 1502 451Is 1146 28/8 721 16/4 425 1 211/2 546 578 1 262 654 297 10 250 573/4 1467 453/4 1162 8I16 208 1 66 1676 491/2 1257 321/2 826 17/16 440 1 24 610 795 361 965 438 M300BFG, M300NBFG A C I 0 6 H I J P M300BFG M300NBFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lb&ks.lbs.kgs. 21/2 65 27/4 705 8 203 1 31/2 89 29/8 759 1 211/2 546 141 I,6 379 1 81 /16 223 13 330 70 32 1 78 35 3 80 281/4 718 1 8/16 211 311/16 94 303/4 781 221/4 565 1 15/16 392 1 9I16 233 1 131h 343 1 68 31 1 81 37 4 100 353/4 908 811/16 221 41 /16 122 39 991 301I4 768 18 457 1111/16 297 15 381 133 60 156 71 6 150 40I4 1035 10 254 6 152 47/16 1205 371h 953 2011/16 525 14/1 360 1 191/2 495 225 102 265 120 8 200 473/4 1213 12/16 310 613/16 173 1 56 1422 451/8 1146 241/8 613 16I4 425 1211h 546 359 163 435 197 Noryl® is a registered trademark of SABIC Innovative PlastiCSTM Approvals Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The Unversity of Southern California (FCCCHR-USC) AWWA C551-92 For additional approval information please contact the factory or visit our website at www.amesfirewater.com ** ** is FM (9 CCPUS C Approved 1048 B64.5 rBFG & OSY Only) - Horizontal - Vertical -----N-Pattern 2114" (65MM) 2eivice How Rated Now 'II -- _._ -- _. — — __,..l_. _. — — —at — 0 50 100 150 200 250 300 350 9pm 0 190 380 570 760 950 1140 1330 1pm 7.5 15 fps Capacity ULJFM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. See literature S-MAXIM-200/300 for gate valve flow characteristics Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. Rated Flow identifies maximum continuous duty performance determined by AWWA. UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than lofps. psi 12 10 00 4 '-2 0 6" (150mm) Service flow Rated flow *UL Rated Flow N H V 0 300 600 900 1200 1500 gpm O 1140 2280 3420 4560 5700 1pm 7.5 12 fps psi 14 12 10 8 6 '-4 psi 12 10 8 cc Z ° 1 6 2 psi 12 10 8 h 6 4 '-2 0 3" (80mm) Service Flow Rated Flow IlL Rated How H N V 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 1pm 7.5 15 fps 8" (200mm) service Flow Rated Flow *UL Rated flow N H V O 500 1000 1500 2000 2500 gpm 0 1900 3800 5700 7600 9500 1pm 7.5 10 fps psi 4" (100mm) 12 Service Flow Rated flow *UL Rated Flow N 10 V H 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 1pm 7.5 13 fps psi 12 10 10" (250mm) service Row Rated flow *UL Rated Row 4 cc z 6 00 - X2 4 0 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 1pm 7.5 10 fps is 8 6 4 '-2 n Inquire with governing authorities for local installation requirements INCS VA HOEHN PORSCHE CARLSBAD 6800 Avenida Encinas Carlsbad, CA AUTOMATIC WET FIRE SPRINKLER SYSTEM Material Submittal Table of Contents MATERIAL Page# Sprinkler Heads 01 -28 Valves & Gauge 29 -48 Grooved Fittings 49 -59 Steel Pipe & Fittings 60-70 Hangers & Seismic Assemblies 71-83 Electrical & Accessoric Fire-Stopping FPC20I7-0377 6800 AVENIDA ENCINAS HOEHN PORSCHE -SPRINKLER >100(1200 HEADS) DEV2017-0015 2144501600 12/20/2017 FPC20I 7-0377 P.O. Box 713194 Santee, CA 92072 (619) 562-6247 fax (619) 562-6273 tqCU Fire & Building IlProducts Customer Service/Sales: Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010 / (800) 877-1295 Series ELO-231 Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description The 11.2 K-factor, Series ELO-231, Standard Response, Standard Cover- age, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprin- klers of the fusible solder type. They are standard response - spray sprin- klers" that produce a hemispherical water distribution pattern below the deflector. The 11.2 K-factor, ELO-231 Sprinklers were subjected to full scale, high-piled storage, fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor standard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, ELO-231 Sprinklers -_ mak- ing their use highly advantageous in high density applications, such as the protection of high-piled storage. Wax or lead coatings can be used to extend the life of the copper alloy com- ponents used in Series ELO-231 sprin- klers beyond that which would other- wise be obtained when exposed to corrosive atmospheres. Although wax and lead coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all pos- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. sible corrosive atmospheres. Conse- quently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resis- tant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemi- cals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An upright intermediate level version of the Series ELO-231 Sprinklers for in-rack applications can be obtained by utilizing the Series ELO-231 Up- right Sprinkler with the WSG-2 Guard & Shield, and a pendent intermediate level version of the Series ELO-231 Sprinklers can be obtained by utiliz- ing the Series ELO-231 Pendent Sprinkler with the WS-2 Shield. If there is a possibility of the pendent interme- diate level version being exposed to mechanical damage, a G-2 Guard can be added. WARNINGS The 11.2 K-factor, Series EL 0-231 Upright and Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions. Installation of Series ELO-231 Pen- dent Sprinklers in recessed escutch- eons will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and/or Listings. Page 1 of 6 MARCH, 2007 TFP340 Page 2 of 6 TFP34O SPRINKLER FINISH TYPE TEMPERATURE FRAME COLOR NATURAL BRASS I CHROME PLATED LEAD COATED I WAX COATED I WAX OVER LEAD UPRIGHT (TY5111 & TY5811) 165FI74°C Unpainted 1,2,3,4 ___________ 1,2,3,4 212°Fl100C White 1 286°F1141°C Blue 1,2,3,4 10),2(a),3(a),4(a) 165°FI74C Unpainted 1, 2,4 (TY5211 212°FI100°C PENDENT 1,2,3,4 White 286°F/141°C Blue 1, 2,4 10) 20),40) NOTES: Listed by Underwriters Laboratories, Inc. (UL Listed). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL Listed). Approved by Factory Mutual Research Corporation (FM Approved). Approved by the City of New York under MEA 291-04-E. (a). Listed/Approved for a maximum ceiling temperature of 150°F166°C. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K-FACTOR SERIES ELO-231 UPRIGHT AND PENDENT SPRINKLERS (Refer to the Design Criteria Section) Model/Sprinkler Identification Numbers TY5III -Upright 11.21K, 314"NPT TY5211 - Pendent 11.2K, 314"NPT TY5811 - Upright 11.21K, 112"NPT TY5II I is a redesignation for C51 11 TY521 I is a redesignation for C521 I TY5811 is a redesignation for C5811 Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved.(Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 11.2 GPM/psil/2 (161,4 LPM/barl'2) Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame .............Bronze Seal Disc ..........Copper Cap ..............Bronze Strut Assembly . . . Solder, Bronze, Stainless Steel Compression Screw .....Bronze Deflector ............Bronze Helper Spring . . . . Stainless Steel Ejector Spring .........Nickel Strut Clip ......Stainless Steel Design Criteria UL and C-UL Listing Requirements The 11.2 K-factor, Model ELO-231 (TY5111, 1Y5211 & TY5811) Sprin- klers are to be installed in accordance with NFPA 13 standard sprinkler posi- tion and area/density flow calculation requirements for light, ordinary, or ex- tra hazard occupancies, as well as high piled storage occupancies (solid piled, palletized, rack storage, bin box, and shelf storage including but not lim- ited to Class l-IV and Group A plastics) with a minimum residual (flowing) pressure of 7 psi (0,5 bar) for wet or dry pipe systems. FM Approval Requirements The 11.2 K-factor, Model ELO-231 (TY51I1, TY5211 & TY5811) Sprin- klers are to be installed in accordance with the applicable "control mode den- sity/area" guidelines provided by Fac- tory Mutual. (FM guidelines may differ from UL and C-UL Listing criteria.) Page 3 of 6 TFP34O * Temperature rating is indicated on deflector. ** Pipe thread connections per ISO 7/1 can be provided on 1/2' (12,7 mm) special request. NOMINAL MAKE-IN 3/40** _ II II _ ___ NPT 2-13/16" (71,4 mm) !WRENCH JHREAD TYP. FLATS RELIEF 3/40** NPT NPT t... 7/16"(ll,lmm) L NOMINAL MAKE-IN NOMINAL MAKE-IN Components: 1 1 - Frame 2 - Seal Disc 2 3-Cap 4- Strut 3 Assembly 4 5 - Compression Screw 6 - Deflector* izz4 7- Helper Spring 6 8 - Ejector Spring 9 - Strut Clip UPRIGHT UPRIGHT PENDENT CROSS TY5811 TY5III TY5211 SECTION FIGURE 1 11.2 K-FACTOR SERIES ELO-231 UPRIGHT - 3/4" NPT (TY5III), UPRIGHT - 1/2" NPT (TY5811), AND PENDENT - 3/4" NPT (TY5211) SPRINKLERS Operation A fusible alloy is sealed into a bronze actuating rod (center strut) by a stain- less steel ball. When the alloy melts at its rated temperature, the ball is forced upward into the center strut, releasing the two ejectors and operating the sprinkler. Installation The Series ELO-231 Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES A leak tight 3/4 inch NPT sprinklerjoint should be obtained with a torque of 10 to 20 ft. lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft. lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT connections. A leak tight 1/2 inch NPT sprinkler joint should be ob- tained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series ELO-231 Upright and Pendent Sprinklers must be installed in accordance with the following in- structions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS FIGURE 2 W-TYPE 3 SPRINKLER WRENCH 3 Sprinkler Wrench (Ref. Figure 2), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figure 1, the W-Type 3 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen Page 4 W6 TFP34O the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. Care and Maintenance Series ELO-231 Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system control valve for maintenance work on the fire protection system that it con- trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over-heated sprinklers must be replaced. Care must be exercised to avoid dam- age to the sprinklers - before, during, and. after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the long term potential integrity of the sprinkler coatings. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national code. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. A Part Number (PIN) is not specified when ordering sprinklers with thread connections per ISO 7/1. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connection: Specify: (specify SIN), 11.2 K-factor, (specify temperature rating), Series ELO-231 Standard Response (specify Pendent or Upright) Sprinkler with (specify finish), P/N (specify from Ta- ble B). Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, PIN 56-895-1-001. 110 UPRIGHT 3/4" NPT (TY5II1) 112 PENDENT 3/4" NPT (TY5211) 210 UPRIGHT 1/2" NPT (1Y5811) TYPE SPRINKLER I TEMPERATURE RATING - 1 NATURAL BRASS 9 CHROME PLATED 165 165°F/74°C 6 WAX COATED 212 212°F/100°C 7 LEAD COATED 286 286°F/141°C 8 WAX OVER LEAD TFP34O Page 5 of 6 Ordering P/N 50-XXX-X-XXX Procedure Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries ELO-231 Sprinklers, PIN (spec- ify)- Red for 165°F .............P/N 56-065-1-155 Blue for 212°F and 286°F ................. P/N 56-065-1-286 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 212°F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 2 12°F sprinkler (i.e., 150°F). TABLE B PRODUCT SYMBOL NUMBER SELECTION 11.2 K-FACTOR SERIES ELO-231 STANDARD RESPONSE UPRIGHT AND PENDENT SPRINKLERS tqca Fire Protection Products Worldwide Contacts I www.tyco-fire.com Model K17-231 - 168 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO 16.8 K-factor, Model K17-231, Standard Response, Standard Coverage, Upright and Pendent Sprin- klers (Ref. Figure 1) are automatic sprin- klers of the frangible bulb type. They are "standard response spray sprin- klers" which produce a hemispherical water distribution pattern below the deflector. The 16.8 K-factor, K17-231 Sprinklers were subjected to full scale, high-piled storage, fire tests to qualify their use in lieu of 8.0 or 11.2 K-Factor standard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 16.8 K- factor, K17-231 Sprinklers - making their use highly advantageous in high density applications, such as the pro- tection of high-piled storage. Applications for the 16.8 K-factor, Mod- el K17-231 Pendent and Upright Sprin- klers are expanding beyond the cur- rent listings/approvals. For information regarding research fire tests which may be acceptable to an authority having ju- risdiction, please contact the Technical Services Department. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 The 16.8 K-factor, Model K17-231 Up- right and Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the Na- tional Fire Protection Association, in ad- dition to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY7151 - Upright, 16.8K TY7251 - Pendent, 16.8K TY7151 is a redesignation for C7151, G1888, and S8040. TY7251 is a redesignation for C7251, G1889, and S8041 Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Specific details for laboratory listings and approvals given in Table A. The approvals apply to the service con- ditions indicated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficient K = 16.8 gpm/psi112 (241,9 1pm/bar1'2) SEPTEMBER 2014 Temperature Ratings Refer to Table A. Finish Natural Brass Physical Characteristics Frame ...................Bronze Button...................Bronze Sealing Assembly.........Beryllium Nickel w/TEFLON Bulb (5 mm) ................Glass Compression Screw.........Brass Deflector..................Brass TFP332 TFP332 Page 2 of 4 BULB SPRINKLER FINISH TYPE TEMPERATURE LIQUID NATURAL BRASS 155-F (68-C) Red UPRIGHT K=16.8 (TY7151) 1,2,3,4 200°F (93°C) Green 286°F (141°C) Blue 155-F (68-C) Red PENDENT K=16.8 (TY7251) 1,2,4 I 200°F (93°C) Green 286°F (141°C) Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL Listed). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL Listed). Approved by Factory Mutual Research Corporation (FM Approved). Approved by the City of New York under MEA 177-03-E. TABLE A LABORATORY LISTINGS AND APPROVALS (Refer To The Design Criteria Section) Design Criteria UL and C-UL Listing Requirements The TYCO 16.8 K-factor, Model K17-231 (TY7151 & TY7251) Sprinklers may be installed in accordance with NFPA 13 standard sprinkler position and area/ density flow calculation requirements for light, ordinary, or extra hazard oc- cupancies with a minimum residual (flowing) pressure of 7 psi (0,5 bar) in wet or dry pipe sprinkler systems, or they may be installed in accordance with NFPA 13 standard sprinkler posi- tion and area/density flow calculation requirements for high piled storage oc- cupancies (solid piled, palletized, rack storage, bin box, and shelf storage in- cluding but not limited to Class l-IV and Group A plastics) with a minimum resid- ual (flowing) pressure of 7 psi (0,5 bar) for wet or dry pipe systems. The following two examples are typical of the types of arrangements permit- ted by NFPA 13. For all combinations of lesser and greater building heights, lesser and greater storage heights, storage arrangements, commodity classifications, and lesser or greater re- quired design densities, refer to NFPA 13 for specifics. Example 1: NFPA 13 provides ceiling only protection (that is, no in-rack sprin- klers) criteria using open frame (that is, no solid shelves) single, double, multi- ple-row, or portable rack storage (with- out the need for in-rack sprinkler pro- tection) of cartoned unexpanded Group A or B plastics, or, cartoned expanded Group A or B plastics, with: a storage height of up to 20 feet (6,1 m); a maximum ceiling height of 27 feet (8,2 m); a minimum deflector to top of storage clearance of 18 inches (457 mm); a minimum design density of 0.60 gpm/ft2 (24,4 mm/mm); a minimum residual (flowing) pressure of 7 psi (0,5 bar); a minimum design area of 2000 ft2 (186 m2) for wet systems or 2600 ft2 (242 m2) for dry pipe systems Example 2: NFPA 13 provides ceiling only protection (that is, no in-rack sprin- klers) criteria using open frame (that is, no solid shelves) single, double, multi- ple-row, or portable rack storage (with- out the need for in-rack sprinkler pro- tection) of cartoned unexpanded Group A or B plastics, or, cartoned expanded Group A or B plastics, with: a storage height of up to 25 feet (7,6 m); a maximum ceiling height of 30 feet (9,1 m); a minimum deflector to top of storage clearance of 18 inches (457 mm); a minimum design density of 0.80 gpm/ft2 (32,6 mm/mm); a minimum residual (flowing) pressure of 7 psi (0,5 bar); a minimum design area of 2000 ft2 (186 m2) for wet systems or 4500 ft2 (418 m2) for dry pipe systems FM Approval Requirements The TYCO 16.8 K-factor, Model K17-231 (TY7151) Upright Sprinklers may be in- stalled in accordance with the applica- ble control mode density/area guide- lines provided by Factory Mutual. (FM guidelines may differ from UL and C-UL Listing criteria.) TFP332 Page 3 of 4 1 - Frame 2 - Button 5 3 - Sealing Assembly __________ Bulb 1/2' Deflector* (12,7 mm) ________ ________ 2-3/8 MAKE-IN I 6 - Compression Screw : NOMINAL (60,3 mm) * Temperature rating is indicated on deflector. 1 f WRENCH 3/411 FLAT NPT CROSS SECTION UPRIGHT PENDENT FIGURE 1 MODEL K17-231 UPRIGHT (TV7I5I) AND PENDENT (TY7251) SPRINKLERS Operation The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Installation The TYCO Model K17-231 Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontal, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). Step 1. With pipe thread sealant ap- plied to the pipe threads, hand tighten the Model K17-231 Sprinkler into the sprinkler fitting. Step 2. Using the W-Type 8 Sprin- kler Wrench (Ref. Fig. 2) applied to the sprinkler Wrench Flats (Ref. Fig. 1), tighten the Model K17-231 Sprinkler into the sprinkler fitting. A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprin- kler inlet with consequent leakage or impairment of the sprinkler. Care and Maintenance The TYCO Ultra K17 Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprin- klers that have been exposed to corro- sive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). \ WRENCH RECESS FIGURE 2 W-TYPE 8 SPRINKLER WRENCH The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer' with any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local re- quirements and/or national codes. TFP332 Page 4 of 4 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: (specify SIN), 16.8 K-factor, Model K17-231, (specify) temperature rating, (specify Pendent or Upright) Sprinkler, P/N (specify): Upright (SIN TY7151) 155°F (68°C) ..........P/N 51-888-1-155 200°F (93°C) ..........P/N 51-888-1-200 286°F (141°C) .........P/N 51-888-1-286 Pendent (SIN 1Y7251) 155°F (68°C) ..........P/N 51-889-1-155 200°F (93°C) ..........PIN 51-889-1-200 286°F (141°C) .........P/N 51-889-1-286 Sprinkler Wrench Specify: W-Type 8 Sprinkler Wrench, P/N 56-892-1-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. t co TEFLON Is trademark of The DuPont Corporation Fire Protection Products Worldwide tqCL7 Contacts Series RFII - 5.6 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate/ Retainer Assembly and a Sprinkler/ Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. LIJt(II The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 —3mm bulb TY3551 —5mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. MARCH 2013 TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (1Y3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/psi112 (80,6 LPM/barl'2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFPISI SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO RETAINER SUPPORT I WITH THREAD CUP UNTIL 0 0 'l_— DIMPLES MOUNTING SURFACE IS 11 EJECTION FLUSH WITH 11 SPRING CEILING H / SOLDER ' '-.. COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY 1/2 NP1 FRAME SUPPOR CUP Will ROLL FOR THREAD GUIDE PINS (2) DEFLECTOR I JLJL_- -- EALING SEMBLY CAP BULB PRESSION CREW LECTOR OPPED POSITION) TFPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel WI TEFLON Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFll 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFll Concealed Pendent Sprinklers are only listed and approved with the Series RFll Concealed Cover Plates having a factory applied finish. Wi L.JtIW Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFlI 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and 3/16 to 11/16 (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B MANUFACTURER DEFLECTOR PRESET GAP IN DROPPED 3/32 (2,4 mm) POSITION COVER PLATE DIAMETER DIMENSION A COVER PLATE RETAINER ASSEMBLY 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate/ Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step S. Screw on the Cover Plate/ Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER DIMENSION 77A TFPIBI Page 4 of 4 Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, "Royal Flush II" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C) 200°F (93°C 1Y3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) .165°F (74°C)(b) Grey White (RAL9002).... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) .... 56-792-3-135 56-792-3-165 Signal White (RAL9003).... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 59-792-6-165 Brushed Chrome........56-792-8-135 56-792-8-165 Chrome........56-792-9-135 56-792-9-165 Custom ........56-792-x-135 56-792-x-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright 0 2013 Tyco Fire Products, LP. All rights reserved. two is trademark of The DuPont Corporation. Worldwide tCD Contacts Series TY-B, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers described in this data sheet are standard response, standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TV-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-B Sprinklers are described in Technical Data Sheet 1FP352. Sprinkler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 LDJtLII The TYCO Series TV-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Numbers (SINs) TY315 ......Upright 5.6K, 1/2 NPT Pendent 5.6K, Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K = 5.6 GPM/psill2 (80,6 LPM/bar112 Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) 360°F (182°C)t tUL, C-UL, and VdS Approved only JANUARY 2013 Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI52 TFPI52 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON CROSS SECTION 116 7/ (11,1 mm) cv I NOMINAL MAKE-IN 2' (50,8 mm) 1/2 NPT** UPRIGHT 2" (50,8 mm) _I I 1-3/8" I (34,9 mm) WF __________ Fl DEFLECTOR * PENDENT 2-7/8' (73,0 mm) DIA. RECESSED PENDENT FIGURE 1 SERIES TV-B UPRIGHT (TY315) AND PENDENT (TV325) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Preven- tion Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TV325) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TV-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS - / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI52 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TV-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 15 or Style 20 Closure over the Series TV-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TV-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Thereafter, annual inspections per NFPA 25 are required; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. - 2-7/8 DIA. (73,0 mm) - 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER FITTING FLUSH 3/8±5/16' I (9,5±7,9 mm) 5/8 (15,9 mm) _ 1 • \ J MOUNTING 1/8' SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TV-B PLATE 3/4 (19,1 mm) FIGURE 4 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER -_ 2-1/4 DIA. FITTING (57,2 mm) 5/16±1/4' 1/2 (12,7 mm) (7,9±6,4 mm) FLUSH -,> / MOUNTING / SURFACE \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TYB RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI52 Page 4 of 4 P/N* 77 - XXX - X - XXX I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 570 5.6K UPRIGHT (1/2"NPT) TY315 4 SIGNAL WHITE (RAL 9003) 155 155-F (68-C) 571 5.6K PENDENT (1/2 NPT) TY325 3 PURE WHITE (RAL 9010)°° Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-570-4-175-I Eastern Hemisphere sales Only 286 286°F TABLE A SERIES TY-B UPRIGHTAND PENDENT SPRINKLERS - PART NUMBER SELECTION - Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TV-B (SIN), K=5.6, (Upright or Pendent) Sprinkler Standard Response, (specify) temperature rating, (specify) finish, P/N (Table A) Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 135 135°F(57°C) 175 175°F(79°C) 200 200°F (93°C) (141°C) 360 360°F(182°C) wo GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright© 2013 Tyco Fire Products, LP. All rights reserved. t TEFLON is trademark of The DuPont Corporation . tqco Fire Protection Products Worldwide Contacts I www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.61K, 1/2" NPT 1Y323 ......Pendent 5.61K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar"2) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components: 1 - Frame 4 - Bulb 2 - Button 5 - Compression 3 - Sealing Screw Assembly 6 - Deflector* DEFLECTOR * H- 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TV-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector, can be provided on special request. 7/16 (11,1 mm) NOMINAL MAKE-IN 2" (50,8 mm) 1/2 NPT** DEFLECTOR * ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) SEATING SURFACE NPT** NOMINAL MAKE-IN mm - 1-3/8 (34,9 mm) V I WRENCH FLATS I STYLE 15 0r20 RECESSED ESCUTCHEON Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F (570C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 IN- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8' DIA. (73,0 mm) 2-1/4" DIA. FACE OF - (57,2 mm) SPRINKLER FITTING —1 __ FLUSH 3/8±5/16" \ S/ 5/8" (15,9 mm) (9,5±7,9 mm) 1/'- 1/8" URFACE J MOUNTING \_(3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TY-FRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4' (7,9±6,4 mm) 1/2' (12,7 mm) FLUSH SURFACE/ MOUNTING 1/8" mm) 1;8" CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX I I SPRINKLER TEMPERATURE FINISH J- RATINGS I SIN 1 NATURAL BRASS 370 I 5.6K UPRIGHT (1/2NPT) TY313 PURE WHITE (RAL9O1O)°° POLYESTER 371 5.6K PENDENT (1/2 NPD 1Y323 POLYESTER SIGNAL WHITE (RAL9003) Use suffix uI" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I - Eastern Hemisphere sales only TABLE A SERIES TY.FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F(57°C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont corporation. Fire Protection Products tq ca Fire Protection Products Worldwide Contacts I www.tyco-fire.com Series TY-B - 28, 56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description TYCO Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this technical data sheet are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commer- cial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TV-B Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TV-B Pendent Sprinkler can be obtained by utilizing the Series TV-B Pendent Sprinkler in combination with the Model S2 Shield. NOTICE The Series TY-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contract the installing contractor or product manufacturer with any questions. Sprinkler Identification Numbers (SINs) TY1151 - Upright 2.8K, 1/2-NPT TY1251 - Pendent 2.8K, 1/2-NPT TY3151 - Upright 5.6K, 1/2-NPT TY3251 - Pendent 5.6K, 1/2- NPT TY4151 - Upright 8.0K, 3/4-NPT TY4251 - Pendent 8.0K, 3/4-NPT TV4851 - Upright 8.0K, 1/2-NPT TY4951 - Pendent 8.0K, 1/2-NPT NOVEMBER 2014 TFPI5I I11 \ 7/16" I (11 1, mm) I NOMINAL I MAKE-IN I I I 2-3/16" (55,6 mm) 1/ 1/2" NPT** f WRENCH CEILING PLATE SEATING SURFACE /j nm) TFPI5I Page 2 of 8 1 - Frame 5 - Compression 2 - Button Screw 3 - Sealing 6 - Deflector* Assembly 7 - Bushing 1 4 - Bulb 2 * Temperature rating is I indicated on Deflector. II 5 ** Pipe thread connections .Amb_ 6* per ISO 7-1 can be provided on special request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TV-B UPRIGHT (TYII5I) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE I(NOMINAL 7/16" _ L 1-1/2" H 6" 11,1 mm) 16 mm) MAKE-IN 2-3; (556 mm) / ( 1/2" NPT** I WRENCH STYLE 10 k- 2-7/8" (73,0 mm) DIA. -.-] FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TV.B UPRIGHT (TV3151) AND PENDENT (TV3251) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT STANDARD RESPONSE TFPI5I Page 3 of 8 1 - Frame 3 - Sealing 5 - Compression ESCUTCHEON 2 - Button Assembly Screw PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE N 1/2 t _ _'-I, (12,7 mm) I MAKE-IN 2-1/4 (58,7 mm) 1-9/16' NOMINAL I 2-5/16' (57,2mm) (39,7 mm) I 3/4 NPT** f WRENCH STYLE 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEOt FIGURE 3 SERIES TY-B UPRIGHT (TY4151) AND PENDENT (7Y4251) SPRINKLERS 8.0K-FACTOR, 3/4 INCH NPT, STANDARD RESPONSE * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. f-u--- 2-7/8' (73,0 mm) DIA. -i..- RECESSED PENDENT 111 CROSS SECTION CEILING PLATE SEATING SURFACE _T 2-1/4" (57,2 mm) 1-9/16 (39,7 mm) 1 - Frame 5 - Compression 2 - Button Screw i3 - Sealing 6 - Deflector* Assembly T 4 - Bulb * Temperature rating is indicated on Deflector. 5 ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. I 7/16 (11,1 mm) NOMINAL MAKE-IN I I 2-3/16 (55,6 mm) . / 1/2"'NPT** WRENCH FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TV-B UPRIGHT (TV4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE TFPI5I Page 4 of 8 K SPRINKLER TYPE TEMPERATURE RATING COLOR BULB LIQUID SPRINKLER FINISH (8) __________________________ _______________________________ NATURAL BRASS CHROME PLATED POLYESTER*** LEAD COATED WAX COATED WAX-OVER-LEAD COATED - 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT 2.8 1/2- NPT (TY111) and 175°F PENDENT 1, 2, 3 N/A (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Figure 1 Blue 360°F (182°C) Mauve 1,2 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT (TY3151) a -I PENDENT (TY3251) 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 175°F(79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 2°°, 3°°, 5°° 1°, 2°°, 3** 5** 5.6 Figure 2 360°F (182°C) Mauve N/A 1/2 _________ NPT 135°F(57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY3251)* 1,2,3,4,5 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 5 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT (TY4151) .1 PENDENT (TY4251) 1,2,3,4,5,6,7 1,2,5 1,2,3,5 1,2,5 175 F(79 C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1**, 2**, 3* 5** 1**, 2°, 5* 8.0 Figure 3 360°F (182°C) Mauve N/A 3/4 _________ NPT 135°F(57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY4251)* 1,2,3,4,5 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 6 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT 8.0 1/2 NPT (1Y4851) and PENDENT (TY4951) 1,2,3,4,5,6 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 4 360°F (182°C) I Mauve Notes: Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories, Inc. for use In Canada (C-UL) Approved by FM Global (FM Approvals) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k103) Approved by the City of New York under MEA 364-01 -E S. VdS Approved (For details contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a105) Where Polyester Coated, Lead Coated, wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion- Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. Installed with Style 10(1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable 150°F (66°C) maximum ceiling temperature Frame and deflector only N/A - Not Applicable TABLE A SERIES TV—B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFPI5I Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL I CHROME 1 POLYESTER' EAD WAXWAX-OVER-LEAD BRASS PLATED COATED COATED COATED 2.8 UPRIGHT (TYII5I) 1/2 and 175 psi (12,1 bar) N/A NPT PENDENT (TY1251) UPRIGHT (TY3151) and 5.6 PENDENT (TY3251) 250 psi (17,2 bar) (a) 1/2 OR NPT 175 psi (12,1 bar) RECESSED PENDENT (TY3251) UPRIGHT (TY4151) and 175 psi (12,1 bar) 8.0 PENDENT (TY4251) 3/4- NPT RECESSED 2PENDENT 175 psi (12,1 bar) N/A 8.0 UPRIGHT (TY4851) 1/2 and 175 psi (12,1 bar) NPT PENDENT (TY4951) Notes: a. The maximum working pressure of 250 psi (17.2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL). the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL), and the Approval by the City of New York. Frame and deflector only N/A - Not Applicable TABLE B SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved VdS Approved NYC Approved (Refer to Table A for complete ap- proval information, including corro- sion-resis-tant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K=2.8 gpm/psi112 (40,3 1pm/bar112) K=5.6 gpm/psi112 (80,6 1pm/barl'2) K=8.0 gpm/psi112 (115,2 1pm/barl'2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table C. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame.......................Bronze Button..................Brass/Copper Sealing Assembly.......Beryllium Nickel w/TEFLON Bulb .........................Glass Compression Screw............Bronze Deflector.....................Copper Bushing (K=2.8) ...............Bronze Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Global Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. TFPI5I Page 6 of 8 2-7/8 DIA. 5/8±1/4 (73,0 mm) I M' (19,1 mm) (15,9±6,4 mm) - 2-1/4' DIA. I 1/4' (6,4 mm) I FACE OF (57,2 mm) MOUNTING SPRINKLER _i PLATE FITTING 1/811 I I - (3,2 mm) MOUNTING t j SURFACE SERIES 1-1/4 (31,8 mm) CLOSURE TV-B 3/4' (19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH 114(0-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. 5/8±1/4 (73,0 mm) 3/4' (19,1 mm) I (15,9±6,4 mm) 2-1/4' DIA. I 1/4' (6,4 mm) I FACE OF (57,2 mm) MOUNTING SPRINKLER - __ - ____________ (3,2 mm) FITTING PLATE I I _____ 1/8 MOUNTING f I SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) f TV-B 13/16" (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8. K-FACTOR, 314 INCH NPT WRENCH RECESS (END A' USED FOR 1/2 NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4' NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. TFPI5I Page 7 of 8 Upright and Pendent Sprinklers The Series TV-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Note: Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. Step 1. With pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 7). For wax-coated sprinklers, use an 8 or 10 inch adjustable wrench. With reference to Figures 1 through 4, the W-Type 7 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, is to be applied to the sprinkler wrench flats. When installing wax-coated sprinklers with an adjustable wrench, exercise care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment. Open the jaws of the wrench sufficiently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprinkler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating when- ever the coating has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. f•JlL.I Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precau- tions need to be taken when handling the heated rod in order to prevent the installer from being burned. Recessed Pendent Sprinklers The Series TV-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TV-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance TYCO Series TV-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to Installation Section.) The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. FSIN 530 2.8K UPRIGHT (1/2NPT) TY1151 531 2.81< PENDENT (1/2 NPT) TY1251 570 5.6K UPRIGHT (1/2 NPT) TY3151 571 5.6K PENDENT (1/2 NPT) TY3251 590 8.0K UPRIGHT (3/4" NPT) TY4151 591 8.0K PENDENT (3/4" NPT) TY4251 560 8.0K UPRIGHT (1/2" NPT) TY4851 561 8.0K PENDENT (1/2" NPT) TY4951 SPRINKLER I TEMPERATURE FINISH RATING 135 135-F (57-C) 155 155-F (68-C) 175 175-F (79-C) 200 200°F (93°C) 286 286-F (141-C) 360 360°F(182°C) 000 OPEN*** 1 I NATURAL BRASS PURE WHITE (RAL9010) * POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) ** POLYESTER 6 WAX COATED 286°F (141°C) MAX 7 LEAD COATED WAX-OVER-LEAD 8 286°F (141°C) MAX 9 I CHROME PLATED TFPI5I Page 8 of 8 P/N 57 - XXX - X - XXX Notes E : * astern Hemisphere sales only Available in Only 8.0K, 155°F (68°C) or 200*F (93°C); requires lead time to manufacture Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems ("OPEN" indicates sprinkler assembly without glass bulb, button, and sealing assembly) TABLE C SERIES TV-B UPRIGHTAND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TV-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N (Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify) finish, P/N* Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench-damaged wax coating) Specify: (specify color, below) Colored Coded Wax Stick for retouching (specify temperature rating) temperature-rated Series TV-B Sprinklers, P/N (specify) Black for 135°F (57°C) ......P/N 56-065-1-135 Red for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175° F (79°C) .....PIN 56-065-1-175 Blue for 200°F (93°C) and 286°F (141°C) .........P/N 56-065-1-286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. Note: The wax used for 286°F (141°C) sprinklers is the same as for 200°F ('93°C) sprinklers, and, therefore, the286°F(141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F (93°C) sprinkler (i.e., 150°F1660CJ). GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of the DuPont Corporation. Rre Protection Products FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use, a ductile iron body and disc with Nitrile seats. Designed for fire protection services only. Victaulic FireLock Series 705 Butterfly Valve is cULus Listed, LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service. Contact Victaulic for details of agency approvals. APPROVALS AND LISTINGS 2750mm up to 300p51/2O68kPa 2 1/2765mm up to 300p5i/2068kPa 761mm up-to 300psi/20680a 3780mm up to300psV2O68kPa 47100mm up to 300ps1/2068kPa 57125mm up to 300psi/2068kPa 139.7mm _.up to 300psi/2068kPa 61/150mm up to 300ps1/2068kPa 165.1mm up to 300p51/2068kPa 87200mm up t0300ps1/2O68kPa 107250mm - up to 300p51/2O68kPa 127300mm UD to 300o5i/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300p51/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psl/20680a up to 300ps1/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300ps1/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up t0300ps1/2068kPa - - - n/a up to 300psi/2068kPa JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect_ Para__________ Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. 02010 vICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_C Aicna—uhcr 10.81_i IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.81 FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, grade 65-45-12 End Face, 2 - 6I50 - 150 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Seal Retainer, 8 - 121200 - 300 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Coating: Black alkyd enamel Disc: Ductile iron conforming to ASTM A-536, grade 65-45-12, with electroless nickel coating con- forming to ASTM B-733 Seat: Grade "73" Nitrile Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless Steel with TFE lining Stem Seals: Nitrile Stem Retaining Ring: Carbon steel Actuator: 2 - 8/50 - 200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing 10 - 12/250 - 300mm: Steel worm and cast iron quadrant gear, in a cast iron housing www.victauljc.com \J(tauIicr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.81_2 REV_C 2 2.375 4.25 2.28 6.41 4.00 4.22 4.50 2.12 60.3 mm 60.3 2.875 108.0 3.77 57.9 -- 2.28 162.8 - --h-- 7.54 - - 101.6 -. 4.00 107.2 4.22 114.3 450 53.8 1.77 21N 73 mm 73.0 3.000 95.8 3.77 57.9 2.28 191.5 7.54 - - 101.6 4.00 4.22 107.2114.3 4.50 45.0 1.77 76.1 mm 76.1 3.500 95.8 3.77 57.9 2.53 191.5 779 - - 101.6 4.50 107.2 4.22 114.3 4.50 45.0 1.77 88.9 mm 88.9 4.250 95.8 4.63 64.3 2.88 197.9 8.81 - - 114.3 5.50 1072 4.22 114.3 4.50 45.0 2.20 108 mm 108.0 4.500 117.6 4.63 73.2 2.88 223.4j 8.81 - 139.7 550 107.2 4.22 114.3 450 55.9 2.20 114.3 mm 114.3 5.250 117.6 5.88 73.2 3.35 223.8 10.88 - - 139.7 656 107.2 6.19 114.3 6.30 55.9 258 133 mm 133.0 5.500 149.4 5.88 85.1 3.35 276.4 10.88 - - 166.6 656 157.2 6.19 160.0 6.30 65.5 2.58 139.7 mm 139.7 - 149.4 85.1 - 276.4 - - ....4 166.6 157.2 160.0 65.6 S. 5.563 5.88 3.35 10.88 i 6.56 6.19 6.30 2.58 141.3 mm 141.3 6.250 149.4 5.88 85.1 - -I- 3.84 276.4 + 11.38 - - 0.41 - 166.6 • 157.2 7.52 6.19 160.0 630 655 2.58 159 mm 159.0 6.500 149.4 5.88 97.5 3.84 289.1 11.38 10.4 0.41 191.0 7.52 157.2 6.19 160.0 6.30 65.5 2.58 165.1 mm 165.1 6.625 149.4 5.88 97.5 3.84 - -+------I- 289.1 • 11.38 - 10.4 - 0.41 1 191.0 ... - -..- 7.52 157.2 6.19 160.0 6.30 65.5 1.90 6" 168.3 - 168.3 8.625 149.4 5.33 97.5 289.1 5.07 . 1353 10.4 - 0.80 1.47 191.0 10.00 157.2 6.19 160.0 8.10 48.3 233 8" 219.1 mm 219.1 10.750 135.4 4 6.40 128.8 6.37 343.6 .._.. 15.64 20.3 37.3 ... 1.41 1.81 254.0 12.25 15Z2 . 8.10 205.7 - 9.00 59.2 - 10" 273 MM 273.0 12.750 162.6 6.50 161.8 7.36 397.3 16.64 35.8 46.0 2.30 2.80 311.2 14.25 205.7 8.10 228.6 9.00 - 12" 323.9 mm 323.9 : 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 Note: Optional W/15mm tap available. Contact Victaulic for details. IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR DIMENSIONS - 10.81 www.victaulic.com \,#1tauIicr VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_C 10.81_3 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.81 FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. 2 2.375 6 50 60.3 1 2.875 1.8 6 2½ 65 73.0 1.8 76.1 mm 3.000 76.1 3.500 1.8 7 3 80 - 88.9 - 4.500 2.1 - 8 4 100 114.3 2.4 108 mm 108 MM 284 5 5.563 12 125 141.3 133 mm - 5.500 3.7 12 -3.7 12 133 mm 139.7mm 139.7 3.7 6 6.625 14 150 168.3 . 4.2 159 MM 159 mm 6.500 4.3 14 165.1 mm 165.1 8.625 4.2 - 16 8 200 219.1 10.750 4.9 18 10 250 273.0 12.750 5.5 19 12 300 323.9 5.8 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.81_4 \4taulicr REV_C IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.81 FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR PERFORMANCE C, values for flow of water at +60°F/+16°C with a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, Values: AP Q2 Where: Q = Flow (GPM) AP = Pressure Drop (psi) Q = C x ç = Flow Coefficient I 2.375 2 T Actual 170 - 5.563 1200 8 Actual 8.625 3400 60.3 125 141.3 200 I 219.1 4. 2½ 2.875 65 73.0 260 133 mm 133 mm _________ 1200 10 I 250 10.750 273.0 5800 3.000 76.1 mm 76.1 260 139.7 mm 5500 139.7 1200 12 I 300 I 12.750 323.9 9000 I 3.500 80 I 88.9 6 6.625 440 150 168.3 1800 4 4.500 I 100 114.3 820 159 MM 159 min 1800 108 Min 108 mm 6.500 820 165.1mm 1800 1651 Formulas for Kv Values: tP=Q2 Where: - Q= Flow ) Q = i AP=Pressure (bar) K = Flow Factor 2.375 2 60.3 5.563 147 125 141.3 1040 I 200 I 8.625 219.1 2940 2½ 2.875 225 133 mm 133 min 1040 10 10.750 5020 65 73.0 250 273.0 3.000 76.1 mm 225 139.7 mm 5.500 1040 12 12.750 7790 76.1 139.7 300 I 323.9 3 3.500 6 6.625 380 1560 80 88.9 150 168.3 4 4.500 100 114.3 710 159 mm 159 mm 1560 108 mm 108 mm 6.500 710 165.1 mm 165.1 1560 www.victaulic.com vICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vICTAULIC COMPANY. ALL RIGHTS RESERVED. REV.0 4tauiicr 10.815 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.81 FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR SWITCH AND WIRING 1. The supervisory switch contains two single pole, double throw, pre-wired switches. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps © 125 VDC 0.25 amps © 250 VOC Switches supervise the valve in the "OPEN" position. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per termi- nal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 insulated ground lead (green) is provided. Switch #1 = 51 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Si Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe UL LISTED *XTNXATOI CCONDUTUI1ML i co !10AA1 T0D41&I(SISTOR CHt1ING: 250 0C, 050C cOUITCOT*4EC1OR VDr 25 WNEMJTS ___________ OR SNILTAOOSTYJKN HOW swfttht I IndperIc,mmal NOTE: The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe - S2) and the normally closed terminal (blue - Si and blue-with-orange stripe - S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). www.victaulic.com tauiicr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.81_6 REV_C r FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve. Verify you have the latest revision by visiting our website at www.victaulic.com. Further reference can be found in the 1-100 Victaulic Field Installation Handbook. For complete contact information, visit www.victaulic.com j#tauIic 10.81 5662 REV C UPDATED 12/2010 vicTAuLic IS A REGISTERED TRADEMARK OF vICTAULIc COMPANY. C 2010 vIcTAULIc COMPANY. ALL RIGHTS RESERVED. 10.81 SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD- designed for hydrodynamic efficiency and available in 2750 mm - 3/80 mm (Series 717H) and 2 1h"/65 mm - 12"I300mm (Series 717) sizes. Series 717H valves are cULus Listed and FM Approved for service up to 365p5i/2517kPa. See chart below for approved services for the Series 717 valves. In both valve designs, the single-disc mechanism incorporates a spring-assisted feature for non- slamming operation. This spring-assisted, single-disc design achieves a leak-free seal with as little as 5ft /1.5m of head. Series 717 and 717H FireLock Check Valves can be installed either vertically (flow upwards only) or horizontally. A cast flow arrow indicator is provided to assist with proper valve orientation. Both valves include upstream and downstream pressure taps. Each valve is factory-tested to the rated working pressure. For systems requiring a Riser Check option, refer to publication 10.09. Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted to flanged (ANSI CL.150) equipment using either to Victaulic Style 741 Vic-Flange® or Style 744 FireLock flange adapters on either end. Series 717 (4— 121100 —300 mm) Series 717H High Pressure Check Valve (2— 3'I50 - SO mm) cULus FM LPCB Vds - 2750mm upt0365ps1/2517kPa upt0365ps1/25i7kPa upt0365p51/25l7kPa upt0365ps1/2517kPa 2W/65mm upt0365ps1/2517kPa - upt0365p51/25i7kPa up to 365p51/2517kPa up to 365ps1/2517kPa 76.1 mm_ up to 365ps1/2517kPa ypto 365p51/2517kPa upt0365ps1/2517kPa up to 365p51/2517kPa 3780mm up to 365 psi/2517kPa up!0365p51/2517kPa up to 365 psi/2517kPa up to 365ps1/2517kPa 47100mm rVa rLh n/a rva 57125mm . n/a ri/a n/a n/a 139.7 mm ri/a n/a n/a ri/a 6/150mrn - - - -n/a - 165.1mm n/a n/a n/a n/a 87200mm n/a n/a n/a n/a 107250mm n/a n/a n/a ri/a 127300mm n/a n/a n/a ri/a 2/50mm n/a - -. n/a- n/a n/a 2W/65mm upto250ps1/1725kPa - n/a upt0365ps1/2517kPa n/a 76.1 mm up to 250ps1/1725kPa n/a up to 365 psi/2517kPa up to 16bar/232 psi 3780mm up to 250 psi/1725 kPa - n/a up to 365 psi/2517 kPa up to 16bar/232 psi 47100mm upto psi/2413 kPa up to 350p51/2413kPa - - up to 365 psi/2517kPa - up to 16bar/232p51 57125 mm up to 250 psi/1725 kPa up to 250p51/1725 kPa up to 365 p51/2517 kPa n/a 139.7 rn - up to 250ps1/1725kPa upto 250psi/1725kPa up to 365 psi/2517kPa ~. up to 16bar/232ps1 67150mm upto350psL.'2413kPa - upto350ps1/2413kPa upto365psV2517kPa uptol6bar/232psi 165.1 mm up to 250ps1/1725kPa up to 250p51/1725 kPa up to 365 psi/2517kPa - n/a 87200mm upt0350ps1/2413kPa upt0350ps1/2413kPa up10348ps1/2400kPa upto16bar/232ps1 107250 MM up to 250 psVl?25kPa up to 250 psi/I725 kPa up to 1725 kPa/250 psi n/a 12/300rnm up to 250psV1725 kPa up to 250p51/1725 kPa up to 1725 kPa/250 psi n/a JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date___________________________________ WWW.VICTAULIC.COM VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_N \4taulicr 10.081 IPS CARBON STEEL PIPE- FIRE PROTECTION VALVES 10.08 FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB DIMENSIONS - Series 717 - ' J _ _ kg N. in inal Outside Size Diamete, Inche TYPICAL 2½-3765-8OMM 2½ 2.875 3.88 4.26 3.57 3.6 65 73.0 99 108 91 - - - - - - 1.6 76.1 mm 3.000 3.88 4.26 3.57 3.6 76.1 99 108 91 - - - - - - 1.6 _A_ 3 3.500 4.25 5.06 4.17 4.5 4 80 88.9 108 129 106 - - - - - - 2.0 4 4.500 9.63 6.00 3.88 2.75 3.50 2.00 4.50 3.50 3.35 20.0 100 1143 245 152 99 70 89 51 114 89 85 9.1 5 5.563 10.50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0 125 141.3 267 173 114 106 55 149 104 101 12.3 139.7 mm 5.500 10.50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0 ½NPlUpstream Drain ________ 139.7 27 - 173 114 - - 106 55 149 104 101 12.3 (2) W NPT Downstream Drain 6 6.625 11.50 8.00 5.00 4.50 2.38 6.67 4.73 3.89 38.0 (21 2NPT(Drain Optional) 150 168.3 292 203 127 114 .1. 61 169 120 99 17.2 TYPICAL 4- 81100 -200 MM 165.1 mm 6.500 11.50 8.00 5.00 4.50 2.38 6.67 4.73 3.89 38.0 165.1 292 203 127 114 61 169 120 99 17.2 8 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219.1 356 251 154 128 144 55 225 144 146 29.0 10 10.750 17.00 12.00 709 5.96 6.69 2.15 10.92 6.73 100.0 C 250 273.0 432 305 180 151 170 , 55 277 171 - 45.4 . 12 12.750 19.50 - 14.00 8.06 6.91 7.64 2.51 12.81 7.73 . 140.0 E 300 323.9 495 356 205 176 194 64 . 925 196 - 63.5 i-* B (Dw NPT Upstream Drain (2) W NPT Downstream Drain TYPICAL 10 - 127250 - 300 MM DIMENSIONS - Series 717H ________ ____________ 2 8.66 6.46 3.23 1.48 3.02 2.80 - 4.25 10.7 60.3 219.8 164.1 82.1 37.5 76.7 71.0 - 108.0 4.9 21/2 9.37 6.94 3.31 1.66 3.40 338 - - 4.38 13.8 73 238.0 176.3 84.1 42.2 86.4 85.9 - 111.3 6.3 9.37 6.94 76.1 mm 3.31 1.66 3.40 338 - 4.38 13.8 TYPICAL 2760.3 mm - 3188.9 mm __________ 238.0 176.3 84.1 42.2 86.4 85.9 - 111.3 6.3 I 3 I 9.62 7.44 3.53 1.91 3.65 338 4.63 20.0 88.9 244.3 189.0 89.7 48.5 92.7 85.9 - - 117.6 9.1 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1O.08_2 4tauiicr REVN IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.08 FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB MATERIAL SPECIFICATIONS Body: Ductile Iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Body Coating: Series 717H Body: Black Paint Series 717H Endface: Electroless Nickel Series 717 (2½ —3"): PPS Coating Series 717 (4— 121: Black Paint Body Seat: Series 717H - Nitrile 0-ring installed into an electroless nickel plated endface Series 717 (2½ - 31: PPS Coated ductile iron Series 717 (4— 121: Welded Nickel Disc Seal or Coating: Grade 'T" Nitrile (Series 717H ONLY) Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. Grade "E" EPDM (Series 717 ONLY) EPDM (green color code). Temperature range -30°F to +230°F/-340C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. NOT RECOMMENDED FOR PETROLUEM SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: Series 717H (2— 3/50 —80 mm): CF8M Cast Stainless Steel Series 717 (2½ - 3): Aluminum bronze with elastomer seal Series 717 (4— 12/100 —300 mm) Elastomer-coated ductile iron Shaft: Series 717H (2— 3750 -80 mm): Brass Series 717 (2½ —3"): Type 416 Stainless Steel Series 717 (4— 127/100 —300 mm) Type 316 Stainless Steel Spring: All sizes Type 302/403 Stainless Steel Shaft Plug: Series 717H (2 - 3750 —80 mm): Type 416 Stainless Steel Series 717 (2½ - 12765 - 300 mm): Carbon steel zinc plated Pipe Plug: Series 717H (2— 3/50 —80 mm): carbon steel zinc plated Series 717 (4— 127100 —300 mm): Carbon steel zinc plated www.victaulic.com \4taulicr vICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 vICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_N 10.083 10.08 IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB FLOW CHARACTERISTICS The charts below express the flow of water at 6OF/16°C through valve. 5717H / 717HR 10 F 0.11-- 10 100 FLOW RATE - G.P.M. 5717H I 717HR 100.00 tA LA 9 10.00 1.004- 100 1000 FLOW RATE (Litres/Mm) 1000 10000 www.victaulic.com 44itauiicr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. _______________ 10.08_4 . REV_N IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.08 FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB FLOW CHARACTERISTICS The charts below express the flow of water at 60°F/160C through valve. Sill! 717R F 100 1000 10000 100000 FLOW RATE-G.P.M. S717 I 717R 100.00 10.00 100 1000 10000 100000 FLOW RATE (Litres/Mm) www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV.. N j6tauIic 10.08.. 5 r FireLock® Check Valves SERIES 717 - cULus, FM, VdS, LPCB SERIES 717H HIGH PRESSURE - cULus, FM, VdS, LPCB INSTALLATION Series 717 and Series 717H Check Valves can be installed either vertically (flow up only) or horizontally (with hinge on top) - making sure the flow arrow matches the flow direction through the pipeline. Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com \/4tauIiC 10.08 1479 REV N UPDATED 612010 VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 vICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.08 MODEL 1000 3/4" 1" 11/4" 11/2" 2" L The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System. l• The Model 1000 Complies With All Requirements Of NFPA-13, NFPA-13R, And NFPA-13D. L The Model 1000 TESTANDRAIN Is A Single Handle Ball Valve That Is Light Weight And Compact, Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. Li Available In A Full Range Of Sizes From 3/4" To 2" NPT & BSPT, With All Specifiable Orifice Sizes /8", 7/161, 1/a", 17/32", /8" (ELO), 3/4" (ESFR) and K.25. Li The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. Li The Standard Model 1000 TESTANDRAIN Valve Includes A Pressure Gauge Port Tapping And Can Be Ordered With A Relief Valve As A Model 1011 Or 1011 T Li Locking Kit Available Which Provides Superior Vandal Resistance And Prevents Unintentional Alarm Activation. out New Auloc Visit us on the InternetCTOP at MODEL 1000 300 PSI () @ <> TEWmDRAIN. 3/4" 1" 11/4" 11/2" 2" PLAN VIEW FRONT VIEW/VERTICAL INSTALLATION STREET EL FROM BRANCH GAUGE INLET PROVIDED FRONT VIEW/HORIZONTAL INSTALLATION ORIFICE SIZE AVAILABLE - 3/8", 17/16", 1 /2", 17/327, ELO(5/8'), ESFR(3/4n)* and K.25 *Available on 11/2 10 2" size units only. DIMENSIONS - INCHES TO DRAIN STREET EL OR PIPE TO DRAIN RIGHT HAND/STRAIGHT INSTALLATION APPROVALS: U UL and ULC Listed U FM Approved except 3/4" U NYC-BSA NO. 720-87-SM U CA. State Fire Marshall SIZE A B C D E F G H 3/A 5 1,1611 1 1/2" 2 i16" 3 s/s" 3 Ia" 1 'io" 4 910 6 /8" 128mm 31.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm 1" 5 1/1611 1 1/211 2 116" 3 Ia" 3 s/a" 1 13/1611 4 I16" 6 341 128mm 37.58mm 55.65mm I 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm 1 1/4!1 I 5 I16" 1 11/1611 2 I16" 4 1/411 3 slid' 1 15/1611 5 'i" 5 1/211 137.70mm 42.70mm 65.36mm 108.36mm 82.84mm 50.89mm - 141.39mm 192.28mm 6 I16" 1 13/1611 3 1/411 5 1/1611 3 /&' 2 5/3" 8 1/411 10 7'11" I '2 163.38mm 45.50mm 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm 2" 6 /16" 1 13/1611 3 1/4" 5 1/1611 3 74' 2 /8" 8 1/4" 10 I8" 163.38mm 45.50mm I 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm MATERIAL LIST PART: MATERIAL: HANDLE STEEL STEM ROD BRASS BALL C.P. BRONZE BODY BRONZE SIGHT GLASS LEXAN VALVE SEAT IMPREGNATED TEFLON INDICATOR PLATE STEEL HANDLE LOCK SPRING STEEL **3/411 Valve UL listed only. USA 1PATENT ANDIOTHER PATENTSPENDING AGF Manufacturing Inc. Email: inlo@testandrain.com Web: www.testandrain.com 100 Quaker Lane, Malvern, PA 19355 T: (610)240-4900/F: (610) 240-4906 JOB NAME: ARCHITECT: ENGINEER: .,uue I.-ompduulll[y CONTRACTOR: ® RiserPACK and TESTanDRAIN are registered trademarks 01 AGF 3/02 Globe Valves lAux Drain Soft Seat Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product Description The Central Model F15 Soft Seat Bronze Globe Valves are designed for general service as shut-off, throttling, or drain valves. The Central Model F15 Soft Seat Bronze Globe Valves provide positive shut-off under normal operating conditions. They are recommended for water service only. The Central Model Fl 5 Soft Seat Bronze Globe Valves are of cast bronze construction strictly in accordance with ASTM B-62 specifications 85-5-5-5 for superior corrosion resistance. The hand wheel is manufactured from cast iron materials to meet or exceed the requirements of Underwriters Laboratories, Inc., Factory Mutual, The American Water Works Association C-509 and ASTM A-126, Class B Standards. The Central Model Fl 5 Soft Seat Bronze Globe Valves are rated with cold water at 200 psi, non-shock for cold water service, and are tested twice, air under water for consistent quality. The Central Model Fl 5 Soft Seat Bronze Globe Valves have a soft rubber seat for tight shut-off under all operating conditions. (Mfg. Source: Non-Domestic) Bronze Globe Valves Bill of Materials Item Description Material Specification I Body Bronze ASTM B-62 2 Bonnet Bronze ASTM B-62 3 Stem Brass Rod ASTM B-16 4 Disc Holder Brass Rod ASTM B-16 5 Seat Disc NBR Commercial 6 Disc Holder Nut Brass Rod ASTM B-16 7 Disc Nut Brass Rod ASTM B-16 8 Packing Nut Brass Rod ASTM B-16 9 Packing Gland Brass Rod ASTM B-16 10 Packing PTFE Commercial 11 Hand wheel Cast Iron ASTM A-126-B 12 Ident. Plate Aluminum ASTM B-209 13 Wheel Nut Brass Rod ASTM B-16 fl Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, model number, style, orifice size, temperature rating, type of finish and sprinkler wrench. Availability and Service: Central sprinklers, valves, accessories, and other products are available throughout the U.S. and Canada; and internationally through a network of Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company or call (215) 362- 0700 for the distributor nearest you. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from the date of shipment. Please refer to the current Price List for further details of the warranty. Patents: Patents are pending. Conversion Table: 1 inch = 25.400 mm I foot =0.3048m 1 pound = 0.4536 kg 1 foot pound = 1.36 Nm I psi = 6.895 kpa = 0.0689 bar = 0.0703 kg/cm2 IU.S. gallon = 3.785 dm3 = 3.785 liters Conversions are approximate. CENTRAL Central Sprinkler Company 451 N. Cannon Avenue, Lansdale, PA 19446 © 1991 Central Sprinkler Company Phone (215) 362-0700 Printed in U.S.A. FAX F62-5385 F15.0 Bill of Materials Item Description Material Specification 1 Body Bronze ASTM B-62 2 Hand Wheel Cast Iron ASTM A-1 26-B 3 Hand Wheel Nut Steel Commercial 4 Packing Non-Asbestos Commercial 5 Packing Gland Brass ASTM B-16 6 Packing Nut Brass ASTM B-16 7 Stem Brass ASTM B-16 3-Way Globe Valves 1/4 Inch Gauge valve Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product Description The Central Model F17 3-Way Bronze Globe Valves are designed for general service as shut-off, throttling, or drain valves. The Central Model F17 3-Way Bronze Globe Valves provide positive shut-off under normal operating conditions. They are recommended for water service only. The Central Model F17 3-Way Bronze Globe Valves are of cast bronze construction in strict accordance with ASTM B-62 specifications 85-5-5-5 for superior corrosion resistance. The hand wheel is manufactured from cast iron materials to meet or exceed the requirements of Underwriters Laboratories, Inc., Factory Mutual, The American Water Works Association C-509 and ASTM A-126, Class B Standards. The Central Model F17 3-Way Bronze Globe Valves are rated with cold water at 200 psi, non-shock for cold water service, and are tested twice, air under water for consistent quality. The Central Model FI7 3-Way Bronze Globe Valves have a soft rubber seat for tight shut-off under all operating conditions. (Mfg. Source: Non-Domestic) 3-Way Bronze Globe Valves No. 27.3.0 Central Sprink No. 4-7.0 fl Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, model, style, orifice size, temperature rating, type of finish or coating, and sprinkler wrench. Availability and Service: Central sprinklers, valves, accessories, and other products are available through- out the U.S. and Canada, and internationally, through a network of Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company, or call (215) 362- 0700 for the distributor nearest you. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from the date of shipment. Please refer to the current Price List for further details of the warranty. Patents: Patents are pending. Conversion Table: 1 inch = 25.400 mm 1 foot = 0.3048 M 1 pound = 0.4536 kg 1 foot pound = 1.36 Nm I psi = 6.895 kpa = 0.0689 bar = 0.0703 kg/cm2 I U.S. gallon = 3.785 dm3 = 3.785 liters Conversions are approximate. CENTRAL Central Sprinkler Company 451 N. Cannon Avenue, Lansdale, PA 19446 © 1991 Central Sprinkler Company Phone (215) 362-0700 Printed in U.S.A. FAX (215) 362-5385 F17.0 Pressure Gauges Model UI - Water Pressure Gauge Range 0 to 300 psi in 5 psi increments, and 0 to 2000 kPa in 50 kPa increments. 1/4" NPT male pipe connection. Case: 31/2" diameter. Height: 44/4". Accuracy: ANSI B40.1 Grade B (3-2-3%) Underwriters Laboratories Listed Factory Mutual Approved . Model UA - Air Pressure Gauge Range 0 to 80 psi in 1 psi increments, and 0 to 550 kPa in 10 kPa increments. Retard to 250 psi and 1750 kPa. ¼" NPT male pipe connection. Case: 31/2" diameter. Height: 4,V4". Accuracy: ANSI B40.1 Grade B (3-2-3%) Underwriters Laboratories Listed Factory Mutual Approved The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Acsociation, Factory Mutual Research Corporation, or other similar Organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 70 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled Paper - ® (800) 431-1588 Sales Offices Printed in U.SA I I I 11e (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices Revision lines indicate updated or new data. http:/fwww.reilablesprinkler.com Internet Address PG. Printed in U.S.A. 11/96 FireLockO products comprise a unique system specifically designed for fire protection services. FireLock full-flow, elbows and tees feature CAD-developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Fitting Coating: Orange enamel. Red Enamel in EMEA-l. Optional: Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect_ Para Location Date Approved Date www.victaulic.com vIcTAuLIc IS A REGISTERED TRADEMARK OF vICTAULIC COMPANY. © 2010 VICTAUUC COMPANY. ALL RIGHTS RESERVED. REV-1 \4t8U11cr 10.03_i IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings DIMENSIONS .CtoE1 toE1 WE Cto" JIE C to L .: - lb NO. 001 NO. 003 NO. 002 NO. 006 1 ¼ 1.660 - 0.8 0.3 32 42.4 - - - - - 21 0.1 1 ½ 1.900 - - - - - - 0.82 0.4 40 48.3 - - . - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2½ 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm - 3.000 3.00 3.30 2.25 2.4 76.1 76 1.5 57 1.1 - - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4. 22 . 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 10mm 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 1 9mm 6.250 5.50 12.6 3.50 9.2 550 17.9 158.8 140 5.7 89 4.2 140 8.0 - . 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 www.victaulic.com \Jtauhcr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03_2 . REV-1 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings FLOW DATA 116 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 05 116 1900 2.2 1.1 53 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 2½ 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 85 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com 14taLlIjc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV-1 10.033 FireLock® Fittings GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009/009V/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the 'QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com J$ftaLJhcr 10.03 1539 REV I UPDATED 212010 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.03 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) FireLock® Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems. Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket. This reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire protection systems. VicPIusTM Gasket System: In North America, Victaulic® offers a gasket system which requires no field lubrication on wet pipe systems that are hydrostatically tested. The Vic-PlusTM System (patented) is dry, clean, and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. c § LPC and VdS Approve- see notes on paged SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS 40PATENTE0 (PIu tGi,et Sys LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. FM apptoved fot service in 1 ½ -4" pipe. A UL Listed for service up to 4' pipe only. @ UL Listed fot set vice up to 3 only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved Date__________________________________ www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. XoAn-te U I -id REV-1 10.02_1 Rated for wet and dry sprinkler systems at 350 psi/2413 kPa for 1 ¼ -4732-100mm sizes and 300 psi /2068kPa for 4¼ - 87108 - 200 mm sizes; Schedule 10 roll grooved or Schedule 40 cut or roll grooved steel pipe. Style 005 is rigid and does not accommodate expansion, contraction or angular deflection. IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) DIMENSIONS 1¼ 1.660 350 755 0.05 2.75 450 1.88 1.2 32 42.4 2413 3370 1.2 2-14 x 2 70 114 148 0.5 11/2 1.900 350 990 0.05 2-14 x 2/4 3.00 4.75 . 1.88 1.2 40 48.3 2413 4415 1.2 76 121 148 0.5 2 2.375 350 - 15500.07 2- x 5 3.50 525 L88 1.6 50 60.3 2413 6900 1.7 89 133 148 0.7 2½ 2.875 350 2270 0.07 2-14 x 2½ 4.00 5.75 1.88 1.9 65 73.0 2413 10110 - - 1.7 - 102 146 148 .09 76.1 mm 3.000 350 2475 0.07 2-3/8x25 4.13 5.75 1.88 1.9 76.1 -- 2413 11010 1.7 105 146 148 0.9 3 3.500 350 3365 0.07 2-%x25 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 118 156 148 1.0 -- I -----4 ........ - 4 4.500 350 5565 0.16 2-14 x 21/2 5.75 7.25 2.13 3.1 100 114.3 2413. 24770 4.1 146 184 54 1.4 1- - .........4 ------ 108.0mm 4.250 300 4255 0.16 r 2-14x25 5.63 7.25 2.13 3.1 - 108.0 2068 18940 - 4.1 143 184 54 1.4 5 5.563 300 7290 0.16 2-/2 x 3 6.88 9.00 2.13 4.5 125 141.3 + 2068 . 32445 4.1 175 229 54 2.0 - mm 5.250 300 133 6.63 6495 0.16 2 - X 9.00 2.13 4.5 - 133.0 2068 . 28900 4.1 -4 168 229 54 2.0 5.500 300 7125 0.16 6.88 9.00 2.13 4.8 - mm 139.7 2068 31715 4.1 - X 175 229 -- 54 2.2 - --. 6 ------- 1 6.625 300 -.---- 10340 - 0.16 1 1 2 - /2 x 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 203 254 53 2.3 - - . - - + - 159 - 0mm 6.250 300 9200 0.16 2-½x2'4 7.63 10.00 2.13 5.5 159.0 2068 40955 4.1 194 254 54 2.5 165.1mm 6.500 300 9955 0.16 2- ½ x 3 8.15 10.00 2.13 55 165.1 - 2068 44295 - 4.1 - 207 254 54 2.5 8 8.625 300 17525 0.19 2 - 14 x 10.50 13.14 2.63 11.3 200 219.1 2068 78000 4.8 267 334 67 5.1 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for perfor- mance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. Style 005 couplings are con- sidered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar/175 psi. www.victautic.com \JtauIicr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.02_2 REV_I IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America); red enamel (Europe) Optional: Hot dipped galvanized Gasket: Grade "E" EPDM - Type A Vic-Plus' Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Vic-Plus'' Gasket System, requiring no field lubrication for most installation conditions. Grade "L" Silicone Recommended for dry heat, air without hydrocarbons to +350°F and certain chemical services. For dry services, Victaulic continues to recommend the use of Grade "E" Type A FlushSeal9 Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to -400F/-400C. Based on "typical" pipe surface conditions, supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water. Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams. Victaulic continues to recommend the use of FlushSeal gaskets for dry services. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV- I VU4tauiicr 1O.60_3 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUSTM GASKET SYSTEM (NORTH AMERICA ONLY) GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. For complete contact information, visit www.victaulic.com 10.02 1538 REV I UPDATED 9/2006 vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 vIcTAuLIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.02 III IIIIIIIIIIlIIIlIIIlIIIUIIIIIIIIIIIllII WCAS-697KR4 J4'taUIicr Standard Flexible Coupling STYLE 77 ® ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Style 77 couplings are designed with cross-ribbed construction to provide a strong component for pressure piping systems. Sizes 3/4 - 12720 — 300 mm are two-piece housings. For 14— 24/350-600 mm sizes, Victaulic offers the Advanced Groove System (AGS) line of products. Request publication 20.03 for information on the flexible Style W77 AGS coupling. All sizes are provided with plated bolts and nuts. Galvanized and stainless steel housings are also available. Independent testing has shown the Style 77 coupling to be an effective stress relief and vibration attenuation device providing performance superior to braided steel and elastomeric arch-type connectors when used in close proximity to the source of vibration. Refer to 26.04 for vibration information. Independent testing has shown that Victaulic Style 77 flexible couplings provide exceptional functionality during and after earthquake conditions. Refer to 26.12 for further information. Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel. Optional: Hot dipped galvanized and others. Coupling Gasket: (specify choice*)t Grade "E" EPDM (All other sizes) EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold -i-860F/+30°C and hot +180°F/+820C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Optional: Type 316 stainless steel, Grade 6-8M, Class 2. t Supplemental lubricant is recommended for services installed at or continuously operating below 0°F/-18°C. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date____________________________________ www.victaulic.com J4tauIjcr VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV, H 06.04_1 24 SIZES IPS CARBON STEEL PIPE - GROOVED COUPLINGS Standard Flexible Coupling STYLE 77 DIMENSIONS V4 1.050 1,000 865 0-0.06 . 3 24 0.72 2 - 1/8 x 2 54 2.13 4.00 1.75 1.1 20 26.7 - 6900 3850 0-1.6 60 102 44 0.5 1 1.315 1,000 1,360 0-0.06 2 43 057 2 - 1/h x 2 2.38 4.12 1.75 1.2 25 33.4 6900 6050 0-.1.6 48 61 105 44 0.5 1½ 1.660 1,000 2,160 0-006 2 045 2-½x2½ 265 500 - 188 - 20 32 42.2 6900 9610 0-1.6 - 38 67 127 48 0.9 116 1.900 1,000 2,835 0-0.06 1-56' 0.40 2-V2 x2½ 3.13 5.38 1.88 2.1 40 483 6900 12615 0-1.6 79 137 48 1.0 2 - 2.375 1,000 4,430 0-006 1 31 032 2-½x2½ 363 588 188 26 50 - 603 6900 19715 0-1.6 26 92 149 48 1.2 216 2.875 1,000 6,490 0-0.06 0.26 2-½x234 4.25 6.50 1.88 3.1 65 73.0 6900 28880 0-1.6 22 108 165 48 1.4 761 mm 3.000 1,000 7,070 0-0.06 0.26 - 2 ½ X 2~ 438 6.63 1.88 3.2 76.1 6900 31460 0-1.6 1 - 12' 22 111 168 48 15 3 3.500 1,000 9,620 00.06 r-' 0.22 2-½x2~ 5.00 7.13 1.88 3.7 80 88.9 6900 46810 0-1.6 18 ' 127 181 48 1.7 3½ 4.000 1,000 12,565 0-0.06 0-54' 0.19 2-V x31' ' 5.63 &25 1.88 5.6 90 101.6 6900 55915 0-1.6 16 143 210 48 25 4 4.500 1,000 15,900 0-0.13 , 1 -36 0.34 2- /8 x 6.13 8.88 2.13 6.7 100 1143 . 6900 70755 0-3.2 28 .4................. 156 226 54 3.0 1080mm 4.250 1,000 14,180 0-0.13 r - 41' 0.35 - X 2 16 825 6.00 8.63 2.13 11.0 108.0 6900 - 63100 0-3.2 29 . 152 219 54 5.0 5 5.563 1,000 24,300 0-0.13 . , 1 -18 0.27 7 .75 10.65 2.13 10.6 125 141.3 6900 - 108135 0-3.2 -- 2-~x4,4 97 54 4.8 1330mm 5.250 1,000 21,635 0-0.13 r - 21' 0.28 - 20 X 1 7.63 1038 2.13 . 10.0 -. 133.0 6900 96275 0-3.2 24 194 -- 264 54 4.5 m 139.7 mm 5500 1,000 23,745 0-0.13 1 - 18' 02 8 - X 2 20 108 8.63 10.65 2.13 10.0 139.7 6900 105665 0-3.2 24 219 270 54 . 4.5 6 6.625 1,000 34,470 0-0.13 1--5- 0.23 , 2-~X4,4 8.63 11.88 2.13 12.0 150 168.3 6900 153390 0-3.2 18 219 302 54 5.4 Table continued on page 3. See notes on page 3. V4 - 12' SIZES 14 - 22 SIZES www.victaulic.com \/t9uIjC! VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 06.04_2 REV_H 24" SIZES IPS CARBON STEEL PIPE - GROOVED COUPLINGS 06.04 Standard Flexible Coupling STYLE 77 DIMENSIONS 6.250 1000 30,665 0-0.13 , 0.24 2-20x 108 159.0mm . - 8.63 11.50 2.13 13.2 159.0 6900 136460 0-3.2 20 219 292 54 6.0 6.500 1,000 33,185 0_0,13r r 6 - 0.23 2-V4x41/4 - - 165.1 mm - 8.88 11.63 2.13 13.2 165.1 6900 147660 0-3.2 19 226 295 54 6.0 8§ 8.625 800 46,740 0-0.13 0.-50 0.18 2-%x5 11.00 14.75 2.50 20.8 200 219.1 5500 207995 0-3.2 14 279 375 63 9.4 10§ 10.750 800 73,280 0-0.13 0" -40' 0.14 2-1 x6 13.63 17.13 2.63 31.1 250 273.0 5500 326100 0-3.2 12 346 435 67 14.1 12S 12.750 800 102,000 0-0.13 0"-34' 0.12 2-1 x6½ 15.63 19.25 2.63 27.8 300 323.9 5500 453900 0-3.2 397 489 67 12.6 14* 14.000 300 46,180 0-0.13 0"-31' 0.11 4-1 x 3½ 16.63 19.88 2.88 35.6 350 355.6 2065 205500 0-3.2 9 422 505 73 16.1 15* 15.000 300 53,000 0-0.13 0" -29' 0.10 4-1 x5½ 17.88 21.63 3.00 48.8 375 381.0 2065 - 235850 , 0-3.2- 9 454 549 76 22.1 16* 16.000 300 60,320 0-0.13 O"' 0.10 -27 4-1 x 3½ 19.00 22.13 3.00 51.1 400 406.4 2065 268425 0 -3.2 , 9 - 482 562 76 23.2 18* 18.000 300 76,340 0-0.13 0"-24' 0.08 4-1 x3½ 21.38 24.50 3.13 64.4 450 457.2 2065 339710 0-3.2 7 543 622 80 29.2 20* 20.000 300 94,000 0-0.13 0"-22' 0.08 4-1Y8x4 23.63 27.25 3.13 91.2 500 508.0 2065 418300 ' 0-3.2 7 600 692 80 41.4 22 * 22.000 300 114,000 0-0.13 ' o° 19' 0.07 - 4-1Yax4 25.75 29.50 3.13 92.0 550 559.0 2065 507300 0-3.2 6 654 749 80 41.7 24 * 24.000 250 113,000 0-0.13 0" -18' 0.07 6-lV8x4 27.75 31.25 3.13 94.0 600 609.6 1725 502850 0-3.2 6 704 794 80 42.6 § Couplings 8, 10, 12/200, 250, 300 mm sizes available to its standards. Refer to Section 06.17 for details. "Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. f Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for -Y4 - 31/2720 -90 mm; 25% for 47100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. * For cut groove systems only. For 14 - 247350 - 600mm Roll Groove systems Victaulic offers the Advanced Groove System (AGS) line of products. Request publication 20.03 for information on the Style W77 flexible AGS coupling. Z 3/4 - 12" SIZES 14 - 22' SIZES www.victaulic.com 4-:10--ti,UIicr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV-1-11 06.04 3 p1 k.i.i NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR In; mm In; mm Lbs/Ft; kglm LbslFt; kg/rn Unthreaded 1' 1.191 0.830 1.31 2.41 25 30.3 1.2 1.95 - l'/4 1.536 1.059 1.87 1.55 32 39.0 1.6 2.78 - 1'/2 1.728 1.667 2.71 3.44 40 43.9 2.5 4.03 - 2 2.203 2.104 3.79 2.78 50 56.0 3.1 5.64 - 2½' 2.703 2.564 5.10 1.60 65 68.7 3.8 7.59 - 3.314 3.387 7.18 1.48 75 84.2 5.0 10.69 - 4.310 4.473 10.86 1.00 100 109.5 1 6.7 1 16.16 - 1 APPROVED ® The original high-strength light wall sprinkler pipe with superior hydraulics. Dyna-FIow -ABFII is the "original" high-strength light wall sprinkler pipe. With outstanding hydraulic capabilities, Dyna-Flow is recognized as the most popular alternative to Schedule- 10 pipe. Lightweight and easy to cut, Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter (ID) up to 11% larger than Schedule-40 and up to 7% larger than Schedule -10, Dyna-Flow pipe hydraulics are exceptional. Larger ID's enable Dyna-Flow and related components to be down-sized within the system, increasing the potential for job cost savings. For complete Hazen Williams charts, refer to "Dyna-Flow Hydraulic Data Tables". Dyna-Flow pipe has metallurgical properties that provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There are no special processes or equipment needed for fabrication and installation. ® Superior Coating Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABFII". In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. ® Specifications & Approvals Dyna-Flow pipe is manufactured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna-Flow are UL and cUL listed and FM approved. Dyna-Flow is UL and cUL listed for use with roll grooved, plain-end and welded joints for wet, dry, pre-action and deluge systems. It is FM approved for roll grooved, plain end and welded joints for wet systems. Dyna-Flow is available "hot-dip" galvanized** and has been specifically approved by FM for dry system uses. Dyna-Flow complies with NFPA 13 and is rated at 300 psi working pressure. Exceptional hydraulics Lightweight and easy to install Available factory roll grooved ABFII coated ID UL and cUL listed FM approved * See ABFII warranty ** must be ordered in 10 bundle increments 9"~ Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com 01110 • 161005 Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT* Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 02008-10 Tyco Int., All Rights Reserved, STP-S2-3-1 001 I1Ilk.]II NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft; kg/rn Unthreaded Threaded 1,' 1.080 1.330 1.75 11.39 1.00 25 27.4 2.0 2.60 - - 11/4 1.870 2.54 9.50 1.00 32 35.8 2.8 3.78 - - 11h" 1.639 2.290 3.22 9.14 1.00 40 41.6 3.4 4.79 - - 2" 2.104 3.050 4.57 8.41 1.00 50 53.4 4.5 6.80 - - C@ APPROVED Widely accepted substitute for Schedule 40 Standard hanger spacing ABFII coated ID UL and cUL listed FM approved Combining the safety and longevity of Sch-40 with quality and hydraulic advantages. Dyna-Th read' -ABFII pipe is the full line Schedule 40 replacement with the same CRR of Schedule 40, 1.00, providing Dyna-Thread - ABFII with the same life expectancy as Sch-40. With outstanding hydraulic capabilities, Dyna-Thread - ABFII is a more widely accepted product substitution than lightwall threadable pipe when Sch-40 is specified. Dyna-Thread - ABFII's inside diameter is up to 3.6% larger than Sch-40 and provides improved hydraulics. When used in combination with Dyna-Flow pipe, down sizing of pipe and related components often occurs, thereby reducing costs. The consistent quality of steel used to make Dyna-Thread - ABFII facilitates smooth threading and lower maintenance costs. Increased strength and lighter weight allows Dyna-Thread - ABFII to reduce installation fatigue and makes it ideal for retro-fit applications. ® Superior Coating Dyna-Thread - ABFII products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.500" in diameter is coated with our new Antibacterial Formula, "ABEII". In scientific laboratory tests, ABFII proved to have superior resistance to microbial colonization of pipe walls, thereby inhibiting or possibly preventing the onset of Microbiologically Influenced Corrosion (MIC) upon installation and the first 25 flushes of the fire sprinkler system.* ® American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. ® Specifications & Approvals Dyna-Thread - ABFII pipe is manufactured to meet ASTM A-135, Type E Grade A, is in compliance with NFPA-13 and all sizes are rated at 300 psi working pressure. Dyna-Thread - ABFII is UL and cUL listed for wet, dry deluge and pre-action sprinkler systems and FM approved for use in wet systems. Dyna-Thread - ABFII can be hot dip galvanized** to meet FM requirements for use in dry systems. Dyna-Thread - ABFII is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved and plain end fittings. * See ABFII warranty ** must be ordered in 10 bundle increments (") Customer Service (800) 882-5543 Fax: (800) 659-7730 www.aUiedtube-sprinkler.com Cl ie • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT* Harvey, 1160426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 02009-10 Tyco Int., All Rights Reserved, STP-S3-3-1 001 W1 APPROVED - U.undU. ft=fin"VS"RWOMM~ Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 STRAIGHT i 4. Nominal Size Olmernion A Approx. WI. Eoh ¶4 0.69 0.09 6 11.53 0.04 ¶4 0.81 0.14 8 2037 AN ¶4 0.95 0.21 DO 24.13 0.10 ¶4 1.12 0.31 is 28.45 0.14 V4 1.31 030 23 33.21 023 1 1.50 0.79 25 38.10 0,36 1.75 1.19 32 4445 0.54 14 1.94 137 43 4918 0.11 2 2.25 2.43 50 51,15 'L 'a 2½ 2.70 4.33 is 4158 111 3 3.08 6,37 £3 18.23 2.6? 4 3.79 11.03 lCO 96.21 5.tJ 6 5.13 25.98 150 13233 1L18 Dimensional: Fillings: ASME 1116.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16il4 Material: ASTM A-i 97 Galvanizing: ASTM A-I 53 CHol Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fillings: ASME 816.3 Unions: ASME B 16.39 Bushings/Plugs: ASME B16.14 Pressure Testing: All malleable iron Fittings ore tested For through wail porosity using an air under water process. Agency Approvals: All malleable iron Fittings and unions are Lit listed and FM Approved. British Standard threading per 5521 available upon request. http://www.anvilintl.com/ProductSearchlPrintPrOduCt.aSPX?lid=43 81 1/8/2014 Print Page 2 of 5 NVJLI Malleable Iron Screwed Fittings - Class 150 um APVOVED Oø It III 111401t It REDUCING TEE . Nominal Se Dimensions _______ Apptox. WL Each k ½ 0.91 A rI.D4 0.980.24 8 74t(14 2489 121? 10 1.04 7 4? 103 2616 0.27 012 '4 21 122 399 1.22 31199 1.20 3143 0.37 4111 is is 1 1.36 1.36 1.26 0.49 25. 3451 34j4 3701 1722 '4 '4 is -SOIS 120 112 26 ' 1.22 181 0.38 V '4 13 1.22 1.31 0.45 '4 15 'A 8 LOS 2661 1.05 2W2743 1.08 0.36 019 JO 1.12 784(1 1.12 2845 1.13 7810 0.39 018 '4 2 W 120 120 1.22 0.43 15 . 304 .ios 30.99 020 1.45 1.15 1.31 0.62 25_1 383 3683 1845 078 '4 8 1 25 150 .981(1 1.18 7991 1.50 3(1W 63 079 126 1.12 1.36 0.48 '4 15 15 3201 784 94(14 0.72 20 137 3401 127 7845 145 34(14 03F (1 2(1 1 150 136 1.50 0.67 ______ 25 3 710 3454 321(1 4130 '4 126 1.20 1.36 0.53 '4 20 IS 32121 3148 3454 024 '4 .20 . 1.31 34 1') 1.31 .377 1.45 36 fij 0.61 028 1 1.50 1.15 130 0.11 25 75 3819 3483 3810 037 '4 1.18 118 121 0.57 10 1 7991 799/ 37.76 07 '4 126 126 136 0.6 15 370(1 37 (1 34.5.4 078 '4 7(1 I37 2345 137 2845 1.45 34.8.9 0.69 03? 1 75 1W 32 51 424? 4247 758 i i 0.43 1½ 180 1.80 .L61 1.65 1.07 4(1 4522 4512 41.91 .0.91 049 2 50 2.07 5.131 2.02 5131 1.13 1 ON 1.45 046 Dimensional: Fillings: ASME B16.3 Unions: ASME 816.39 Bushings/Plugs: ASME B 16.114 Material: ASTM A.1 97 Galvanizing: ASTM A-153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating; Fittings: ASME 8 16.3 Unions: ASME Bi 6.39 Bushings/Plugs: ASME 816.14 Pressure Testing; All malleable iron fittings ore tested For through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions ore UL Listed and FM Approved. * British Sicindard threading per BS 21 available vpon 'request. REDUCING Nominal Size ______ Dimensions Approx. WI. Each . B C m. Uieii) k rnu k ie& In. 41isn 1k fig) 1h is T 25 1.58 4013 1.36 305.4 1.67 4747 0.82 031 1 V4 32 1.15 4445 1.53 .9(186 1.75 4445 0.95 043 'W 1.45 1.31 1.62 0.75 '4 73 34.83 I 32 2) 4115 0.34 T 1.58 1.45 1.67 0.81 20 5 4113 76.83 4242 039 1 4 3 1.75 4445 1.62 41.1$ 1.75 44.45 LOG 045 h 1.34 1.26 1.53 0.74 320 3886 34 1 1- 1½ 72 1 75 73 3433 7845 41 15. _ 14 _ 031 T 75 58 4213 1.50 3910 4242 0.94 (1 43 32 1.75 4445 147 1 4742 1.75 44.45 1.08 049 114 32 'T tO 1.26 370(1 1.26 3712(1 1.44 345.9 0.78 03(1 W 15 134 3104 1.34 31.04 1.53 3884 0.84 0.33 W .JL. 1.45 -74V 1.45 --A 83 162 4115 052 _04L. 1 +4013 138 1.53 1913 167 042 1.01 1 047 40 ]At 4115 1.88 41.75 1.81 44.73 34 01 r 50 T1 53.74 2.10 1 5.3.34 1.0 4376 165 01(1 http://www.anvilintl.comlProductSearchlPrintProductaspx?lid=43 80 1/8/2014 Print Page 4 of 5 Malleable Iron Screwed Fittings - Class 150 REDUCING Nominal Size Ilimensions _______ Approx. WL Each A - C k (WW h6i hi(ort) k(nstl 1k i1 -ic--- 1½ 1.94 1.66 194 124 Ic 40 4928 4214 4928 054 150 1.26 1.69 0.86 16 70 3810 32(8) 493 039 20 115 194 115 1.94 1. 40 4928 4415 49.78 059 - 1 165 130 180 108 25 4797 3810 45)7 049 1 1161.82 1.67 198 1.23 25 32 4423 47.17 41/5 054 1½ 194 1.80 1.94 135 - 40 4978 4517 428 (141 16 70 162 386? 1.45 36 175 4C45 104 041 I 1.65 1.58 1.80 Ui 1½ 40 1½ 75 4191 4013 45.12 053 1½ 32 182 4473 1.75 4445 1.88 4113 1.32 0.40 1½ 194 188 1.94 1.45 4(1 4928 AilS 49.28 014 2 2.10 2.10 1.90 1.82 SO 5231 5334 4871 083. ½ 1.41 1.41 1.66 104 - IS _35L 35777 .A2J4 041 V. 20 1.52 3841 1.57 3861 175 4445 1.14 0.5 1½ 1 1 4I 65 165 180 1.2 40 75 7 4197 4512 41377 W4 32 182 4413 182 44.73 188 41.75 1, 1. 43 11.4.5 216 LTU 102 19 54,44 54.84 51.37 086 2 2.25 1.88 2.25 189 75 54 5715 4715 5115 084 2 2.25 197 2.25 1.93 70 54 5715 54714 5775 088 1 1.81 1.75 1.87 1.39 1 75 1591 1465 47.50 063 25 2 39 2.25 5115 2.07 5171 2.25 5115 100 091 1½ 1.90 115 2.10 1.64 32 4826 4445 5334 014 1% i5 2.02 1.88 2.16 1.80 32 40 5731 11.15 56 81 0 87 123 2.10 775 2.09 2 Ml 5115 5334 5115 4195 1 113 1.65 2.02 1.57 15 4394 419, 51.31 017 2 1¼ 190 182 2.10 1.71 so 1½ 40 37 1874 4673 5334 7118 1½ 2.02 1.94 ..I97&. 2.16 86 1.88 085 2 2.25 2.16 2.25 2.21 MI 5715 56F6 57.15 1. 149 1.49 188 163 15 3785 31.85 4715 069 16 1.60 160 1.91 40 64 1.6T- 29 4044 5904 014 1 25 49..I3J 173 4391 1)3 4394 2.02 51.37 1.78 084 2' so 1'h 37 190 4824 190 4876 2.10 5334 197 010 115 2.02 2.92 2.16 2.12 40 372? 5731 545 096 2½ 2.60 2.60 2.39 3.15 45 £6157 4404 4017 143 REDUCING T Nominal Size -i-- .Eath t Approx. (or) k (an) ______ Dimensions F2,322,67 k (isO (li) 1.74 114 41.70 41.271 7.21 1 1.87 1.81 ..84 25 41.50 4130 4820 729 21h 21h 1½ 2.04 '2.01 2.45 3.09 65 45 32 $782 51.82 4773 7477 -rr- 2.16 2.16 2.51 3.29 (0 54.86 5186 4375 749 7 2.39 7.39 2,60 3.65 50 1 4971 4911 6601 166 I 21 2.89 188 $0 4.401 5115 1341 1/4 - i 70 167 41.50 181 41.50 2.61 4479 3.72 149 T 200 7.00 7.6 3.96 25 50.80 5429 6156 789 3 t 3 80 1 .92 2.17 5.5?? 2.17 55,72 2.74 4940 4.23 192 TW 15 2.29 5911 2.29 5477 210 /717 4.45 207 2 2.52 2.52 289 4.90 50 4101 6407 1347 712 214 2.83 2.83 2.99 5.69 1185 7188 --_ _ _ - SO 6940 4960 1 641 741 4 4 214 3.05 3.05 1 3.51 8.51 I0 7041 45 1141 7741 8915 386 3 3.30 W1 3.60 T25 80 4382 43.82 1 9144 1 420 http://www.anvilintl.com/ProductSearchlPrifltProdUCt.aSPX?Iid=43 80 1/8/2014 !D APPROVED WnOi4 uñdUnU IiIANN sqIMl.10- Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 Nominal Size Dinenson A Approx. WI Ecth ½ 0.69 0.06 6 71.53 0.03 0.81 0.10 8 70.51 0.05 0.95 0.15 10 24.13 001 '.4 1.12 022 75 28.45 0.10 1.31 0.36 20 33.21 0.16 1 150 0.57 25 38.70 0.26 11/4 1.75 0.87 32 4445 0.40 1½ 1,94 1.16 40 4928 0.53 2 2.75 1.81 50 S/iS 0.82 2½ 2.70 3.23 65 63.58 1.41 3 308 412 18.23 2.19 4 3,79 8.41 703 94.21 3.82 6 5.13 19.96 159 ID.30 9,05 Dimensional: Fittings: ASME B16.3 Unions: ASME B16,39 Bushings/Plugs: ASME BI 6.14 Material: ASTM A-i 97 Galvanizing: ASTM A-153 (Hot Dip Galvanizing) Threading*: ASME B1.20.1 Pressure Rating, Fittings: ASME B 16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B 16.14 Pressure Testing: All malleable iron Fittings ore tested For through wall porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions are UL Listed and FM Approved. British Standard threading per OS 21 available upon request http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?Iid=4370 1/8/2014 Print Page 2 of 3 4!W Malleable Iron Screwed Fittings - Class 150 tolD APPROVED = d m. InMr%aiN Rw..1. .111.1 ELBOW Nominal Site Dimensions Approx. WI. Each B k 6W it (ow Uis.tkg) ½ x ½ 0.74 0.76 0.08 926 18.80 1920 . 0.04 34x½ 0.81 0.85 0.11 101.6 1 7151 71.59 0.05 3hxVi 0.88 0.90 0.13 10i8 22.35 22.86 006 ½xVi 0.97 0.98 0.16 15a8 24.64 24.89 001 1.04 1.03 019 15110 2842 2416 009 1.12 1.13 0.26 70x 10 2845 21111 012 1.20 1.22 0.29 20z15 3348 3399 013 lx% 1.18 1.26 0.35 75:10 79.91 3700 0.14 1 x½ 1.26 1.36 0,42 25:15 32.03 34.54 0.19 1x% lx% 1.37 1.45 0.47 25120 ..._..._34.80 36.83 0.21 114x1/, 1.34 1.53 034 37:15 34.01 38.86 024 1%x% 1.45 1.62 0.62 32120 3813 4115 028 11/4 x 1 138 1.61 0.73 37175 4313 4747 033 1 1h x ½ 1.38 1.65 0.65 (OilS 35.05 4191 029 1½x3 1.52 1.75 0.74 (fIx 20 3361 44.45 0.34 1½ x 1 1.65 1.80 0.88 41*25 41.91 45.12 040 1½x1½ 1.82 1.88 1.03 40:32 46.23 41.15 041 2*55 1.50 1.89 0.93 50:15 3310 4801 042 2x 3A 1.60 1.91 1.04 5000 4164 50.04 041 2*1 1.73 2.02 1.28 50:25 43.94 51.31 055 2*1% 1.90 2.10 1.36 50132 4876 5334 067 2x Ph 2.02 2.16 131 50240 51.31 54.88 0.85 Dimensional: Filtings: ,ASME 8`16.3 Unions: ASME B 16.39 Bushings/Plugs: ASME B 16.14 Material: ASTM A-i 97 Galvanizing: ASTM A-153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME 81 6.3 Unions: ASME B16.39 Bushings/Plugs: ASME B 16.14 Pressure Testing: All malleable iron Fittings are tested For through wall porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions ore UL Listed and FM Approved. Brifish Standard threading per BS 21 available upon request. REDUCING 90' ELBOW Dimensiain Nominal Size . .... - Approx. WI. Each AL (AW it (AW it ow 255*155 216 231 2.20 40 54.86 8315 1.03 255*2 2.39 2.60 235 651r53 . 6011 8604 1.16 3*2 232 2.69 3.35 (0:50 6401 1341 1.52 3*2% 2.83 2.99 4.12 (0:65 1188 1595 1.81 4*2 2.72 3.43 5.01 1013150 8909 8117 7.71 4*3 3.30 3.60 6.65 83.87 9144 3.02 http://www.anvilintl.com/ProductSearchlPrintProduct.aSpx?lid=437 1 1/8/2014 Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 c®ss € W1 APPROVO Fii LM ti4ldLl*. imJIIA NM Cull of dwMlliSulN RSSofIIOli COUPLING Nominal Size Dimension A Approx. M. loth 5% 0.96 0.05 6 24.38 0.02 1,06 0.08 8 76.92 0.04 1.16 0.12 10 27.46 0.05 5% 1.34 0.17 15 34.04 0.03 1.52 0.27 20 38.61 012 1 1.67 0.43 25 4242 0,20 1I4 1.93 0.65 32 49.02 0.79 15% 2.15 0.86 40 54.61 0.39 2 2.53 1.35 50 64.26 0.61 255 2.88 2.33 65 13,15 1.06 3 3.18 3.36 80 1'3./1 1.52 4 3.69 5.59 100 9.313 7.54 Dimensional: Fittings: ASME 316.3 Unions: ASME B 16.39 Bushings/Plugs: ASME B 16.14 Material: ASTM A-i 97 Galvanizing: ASTM A-I 53 Hot Dip Galvanizing) Threading*: ASME 31.20.1 Pressure Rating: Fittings: ASME 316.3 Unions: ASME 316.39 Bushings/Plugs: ASME B16.14 Pressure Testing: All malleable iron fittings ore tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron listings and unions are UL Listed and FM Approved. British Standard threading per OS 21 available upon request http://wwwanvilintl .com/ProductSearch/PrintProductaspx?lid=4374 1/8/2014 Print Page 2 of 3 <F~9> Malleable Iron Screwed Fittings - Class 150 IT1 FpOvED REDUCING COUP hMe Nominal Size Dimension It Appiox. Wt. Each '4x½ 1.00 0.07 8:6 2540 0.03 1.13 0,09 I0t6 7810 0.04 1.13 0.10 lotS 78.10 0.05 %x 'A 1.25 0.13 15:6 31.15 0.06 1.25 0.13 15:8 31.15 0.06 1.25 0.14 15:10 31.15 0.06 %x% 1.44 0.18 20:6 3658 0.03 1.44 020 20:8 36.58 0.09 16x% 1.44 0.21 23:10 36.58 0.10 16x'h 1.44 0.22 23,15 36.58 0.10 1.69 0.34 25:15 42.93 0,15 ix% 1.69 0.36 25:20 42.93 0.16 1% x ½ 2.06 0.47 32: 15 52.32 0.21 1% x 414 2.06 031 32:20 52.32 073 I% XI 206 037 32:75 52.32 0.76 1½x½ 2.31 0.62 43:15 58.61 0.78 1½x14 2.31 066 43:20 58.61 033 114x1 2.31 0.73 43:25 58.61 0.33 114x1¼ ' 2.31 ' 0.80 (3:32 58.61 0.36 Dimensional: Fittings: ASME 816.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16J14 Material: ASTM A.1 97 Galvanizing: ASIM A-i 53 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings; ASME B 16.3 Unions: ASME B16.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron Fittings ore tested For through wail porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions are UL listed and FM Approved, British Standard threading per B$ 21 available upon request. REDUCING ICOUPLING Nominal Size Dimension A Approx. Wt. hh k W.htUmi 1k. OW 2 x ½ 2.81 0.94 50:15 11.31 043 2x14 2.81 0.99 50t20 7131 045 20 2.81 1.03 50:23 11.31 0.41 2x1% 2.81 117 301 32 11.31 0.53 2x1½ 2.81 1.25 50:40 11,31 051 2½x)Y: 3.25 1.81 6532 8253 OR 2'4x1½ 3.25 1.90 65:40 $755 0.96 2Wx2 3.25 2.04 - 65:53 - 87.55 0.93 30 3.69 2.48 D:25 93.13 1.12 3x 1% 3.69 2.55 93:32 93.13 1.16 3x 1½ 3.69 2.67 93:40 93.13 1.21 3 x 2 3.69 2.78 93:50 93.13 1.26 214 3.69 3.23 93:65 9313 1.41 4:2 4.38 4.43 103150 11125 2.01 214 4.38 4.07 103165 111.25 7.21 4:3 4.38 5.29 103:93 111.25 7.40 http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=4379 1/8/2014 Print Page 2 of 3 1J111c1 Malleable Iron Screwed Fittings - Class 150 c®ss WI APPROVEO JIuv (ilfldIAtIS. owww Mrs.wI RIINII1. Iu1c Nominal Oinienions Approx. A B C Size W1. Each hi. (air) hi. (.cirt hi. (nvjl KW 1k So'd 0.44 0.28 0.38 0.04 1118 1.11 965 0.07 Said 0.48 0.31 0.44 0.06 JO 12.19 1.8) 1118 0.03 4 0.56 0.38 0.56 0.08 IS 14.22 9.65 14.22 0.04 Cored 0.63 0.44 0.63 0.13 20 16.03 11.18 16.00 0.06 1 0.75 0.50 0.81 0.20 25 19.05 12.10 20.51 0.08 Cored 014 0.80 0.56 0.94 0.32 32 1037 14.77 23.88 015 Cored 1% 0.83 0.62 1:13 0.43 40 71.03 1.15 20.10 0.20 Cored 1 0.88 0.68 1.31 0.67 5? 22.35 1121 33,21 0.20 Cored Th 1.01 0.74 1.50 1.11 65 22.18 1803 3510 0.50 Cored 3 113 0.60 1.69 1.53 03 78. 7VI 20.31 42.93 0.69 got PI T 122 1.00 - 231 100 3299 25.40 - 23 Pk@ 6 1. Bar 1.40 1.25 - 4,00 150 35.56 31.15 - 1.81 Dimensional: Fittings: ASME B16.3 Unions: ASME 816.39 Bushings/Plugs: ASME B 16.114 Material: ASTM A-i 97 Galvanizing: ASTM A-I 53 (Hot Dip Galvanizing) Threading: ASME B1.20.1 Pressure Rating: Fittings: ASME Bi 6.3 Unions: ASME B16.39 Bushings/Plugs: ASME B16.14 Pressure Testing: All malleable iron fittings ore tested for through wail porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions are UL listed and FM Approved. Briiih Slondord threading per BS 21 available upon request. U1111019- http://www.anvilintl.com/ProductSearchlPrintProduct.aspx?lid=4378 1/8/2014 Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 Ul1 APPROYCO OIIidUi leMrs RIy.UtI.e. llomin,l Size Dimension A Appiox. Wt. loth 0.53 0.03 6 73.46 0.I 0.63 0.05 8 76.00 0.02 0.74 0.07 70 1880 0.03 ½ 0.87 0.11 75 2210 0.05 % 0.97 0.18 20 24.64 0.03 1 1.16 0.30 25 29.46 074 114 1.28 0.44 32 32.51 0.70 1½ 1.33 0.55 41 33.18 0.25 2 1.45 0.85 50 36.83 0.39 255 1.70 1.49 65 43.78 0.68 3 1.80 2.20 83 45.12 100 3½ 1.90 3.02 90 48.26 1,31 4 2.08 3.79 100 52.83 2.55 1.12 6 1 8.77 159 64.11 3.98 £ - Sipçkd in Sled ei'4 (BIockd GMniedI. Dimensional: Filtings: .ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME B1&14 Material: ASTM A-i 97 Galvanizing: ASTM A-i 53 IHol Dip Galvanizing Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME 81 6.3 Unions: ASME B 16.39 Bushings/Plugs: ASME B16.14 Pressure Testing: All malleable iron Fittings ore tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron linings and unions are lit listed and FM Approved. Brilush Sondord threading per BS 21 ovoilobla upon request. http://www.anvilintl.com/ProductSearch/PrintPrOdUct.aSPX?lid=4373 1/8/2014 a" Fig. 200 - "Trimline" Fig. 200R (Import) - Adjustable Band Hanger "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/211 thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. WtJ100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 34 2% 400 12 11/4 3/8 8mm or 10mm 3% 27/8 400 13 11/2 3/8 8mm or 10mm 37A 27/8 400 14 2 3/8 8mm or 10mm 41h 3 400 15 21/2 3/8 10mm 5% 41/s 600 27 3 3/8 10mm 5/e 4 600 29 3½ 3/8 10mm 73A 51/4 600 34 4 3/8 10mm 72% 5 1000 35 5 1/2 12mm 91A 61/4 1250 66 6 1/2 12mm 101/8 6-Y4 1250 73 8 1/2 12mm 131A 83/4 1250 136 FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note -Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 -RocLStiffener Size Range - Secures 3/8" 7/8" hanger rod Material - Carbon Steel veismic Function - Secures channel to hanger rod fo ical Approvals - Underwriters Laboratories Listed in the Canada (cUL). Included in our Seismic Restraints C. app Component of State of California USTED Seismic Restrai stem Finish - jtfoGalvanized N-aiIable in HDG finish or Stainless Steel materials. rder By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 -All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions -Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F - 750°F Wt.I100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1¼ 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1315 SAMPSON AVE. • CORONA, CA 92879 'PH: 951.731.5599 • FAX: 951.131.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com C®US LISTED Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe. Material - Steel Function - Designed to be used in conjunction with TOLCOTM Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-61-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed paly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 113 - Standard Hex Nut Size Range - Sizel/4" thru 11/2 Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number size and finish Fig. 114 - Heavy Hex Nut Size Range - Sizel/4" thru 11/2! Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Dimensions 'Weights Width Width Rod Across Across Approx. Size Flats Points Thickness Wt.I100 1/4 7/16 1/2 7/32 .7 5/16 1/2 37/64 17/64 1.1 3/8 9/16 21/32 21/64 1.6 1/2 3/4 55/64 7/16 3.7 5/8 15/16 1I32 35/64 7.3 3/4 11/8 l/th 41/64 12.0 7/8 15/16 1 /64 3/4 19.0 1 11I3 1/4 55/64 28.0 11/4 1I8 211/64 1'/16 54.0 11/2 21/4 219/n 19/32 94.0 Fig. 115 - Flat Washer Size Range - Sizel/4" thru 11/2 Material - Carbon Steel Finish - Plain Note -Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number size and finish Dimensions • Weights Width Width Rod Across Across Approx. Size Flats Points Thickness Wt./100 1/4 1/2 37/64 15/64 1.2 5/16 9/16 21/32 19/64 1.7 3/8 11/16 51/64 23/64 3.1 1/2 7/8 11/6 31/64 6.5 5/8 11/16 115 /64 39/64 12.0 3/4 11/4 129/64 47/64 19.0 7/8 1 /16 121/32 55/64 30.0 1 1/6 1/8 63/64 43.0 11/4 2 2/€ 1/29 79.0 11/2 2/6 2/4 1 /32 131.0 Fig. 117 - Lock Washer Size Range - Sizel/4" thru 3/4' bolt Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number size and finish - Dimensions 'Weights Rod Size Outside Diameter Approx. Wt Il 00 1/4 3/4 .7 5/16 1 1.5 3/8 1/ 3.9 1/2 1/4 7.7 5/8 1/16 7.3 3/4 2 11.0 7/8 21/4 19.0 1 2/4 22.0 11/4 3 26.0 11/2 31/3 39.0 Dimensions 'Weights Rod Size Outside Diameter Approx. WtJ100 3/8 11/16 .6 1/2 7/8 1.3 5/8 11/16 2.4 3/4 11/4 4.0 Page 63 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.137.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com MIN. INSERT E EDGE o• _____ SPACIN( 51t2'NIMUM CONCRETE I I PIP HEAD STAMP THICKNESS ISAT SEISMIC BRACKET, MAY BE ROTATED TO ANY ANGLE /fl AROUND ANCHOR TYP. NPH ATTACHED VIA ISAT SUPPLIED THREADED ROD, HEX NUT. BLUE BANGER PIP INSERT TYP. FORM POUR SLAB WITH 3,000 PSI MIN. NORMAL WEIGHT CONCRETE ..: MINIMUM EDGE ISTANCE a-CONCRETE 60° MAX. TYP. THICKNESS a Blue Banger Hanger Poured-In-Place (PIP) Insert Seismically Qualified for Anchorage In Cracked Concrete Seismic Design Categories C, D, E and F ICC Report No. ESR-3599 (November, 2015), Table I Brace Anchorage Deck Insert AJI Thread Rod Dia. Minimum Concrete Maximum Brace Reaction (Fp) Nominal Insert Minimum Edge 6'M 2 5' Mn. 2 4" Mn 2 Designation Part No. (ATR) Strength Height Distance Inch psi Lbs Lbs Lbs Inch Inch N5B3 P1P143812-2 1/2 3000 ' 587 555 503 N5.1 B3 P1P381258-2 5/8 625 579 526 N5B4 P1P143812-2 1/2 678 1 641 580 4,000 N6B4 P1P381258-2 5/8 722 669 607 N61135 P1P143812-2 1/2 5,000 758 716 649 N6.1 B5 P1P381258-2 518 807 747 679 N71136 P1P143812-2 112 6,000 831 785 711 N7.11136 P1P381258-2 518 884 819 743 BRACE LOAD VALUES SHOWN ARE ALLOWABLE STRESS DESIGN (ASD). CAPACITIES DERIVED IN CONFORMANCE WITH ASCE-7 AND AC1318, APPENDIXD. MINIMUM INSERT SPACING SINGLE BLUE BANGER HANGER "PIP" INSERT SEISMIC BRACE CONNECTION International Seismic Application Technology S4710 14848 Northam Street, La Mirada, CA 90638 877-999-4728 (Toll Free) 714-523-0845 (fax) VCT A Division of Tomarco Contractor specialties www.isatsb.com Rev. 2 11/01/15 Page DI.IB FORM POUR SLAB WITH 3,000 PSI MIN. NORMAL WEIGHT CONCRETE 5 MINIMUM CONCRETE THICKNESS BLUE BANGER PIP INSERT TYP. THREADED ROD, ROD COUPLER. OR HEX NUT TYP. W/ FLAT WASHER HOLE DIA. =ANCHOR DLk+1116' 10' MAX. .d' - 1/2' DIA. BOLT WASHER AND T%'M" STRUT NUT %. PIP HEAD STAMP COPE STRUT TO ALLOW FASTENING TOOL CLEARANCE \ '-15l8'x15/8'x12GA. x 1-0' SOLID STRUT ISAT SEISMIC BRACKET DETAIL A 980 LBS MAXIMUM BRACE FORCE FOR BRACKET ROTATED TO ANY ANGLE AROUND MOUNTING BOLT. OTHERWISE INSTALL BRACE ARM PARALLEL TO CHANNEL LENGTH AS SHOWN. FOR P> 1,440 LBS, USE 3-BOLT BRACKET CONNECTOR, PAGE D2.7 Blue Banger Hanger Poured-In-Place (PIP) Insert Seismically Qualified for Anchorage In Cracked Concrete Seismic Design Categories C, D, E and F ICC Report No. ESR-3599 (November, 2015), Table I Brace Deck Ail Thread Minimum Madmum Brace Reaction (P) Nominal Full Capacity Anchorage Insert Rod Dia. Concrete At Minimum Insert Spacing Insert Edge Part No. . (AIR) 4Designation Strength Height Distance 4 6" Mn. 5" Mn. 4" Mn. Inch psi Lbs Lbs Lbs Inch Inch N81133 P1P143812-2 112 3,000 Bracket Rotated 980 925 838 N8.1 B3 P1P381258.2 5,82 980 965 877 N8.21133 P1P143812-2 112 1,018 962 872 3,000 N9193 P1P381258-2 5,82 1,084 1,004 912 N110134 P1P143812-2 112 1,176 1,112 1,006 ' 4000 2 10 N110.04 P1P381258-2 5/8 2 1,252 1,160 1,053 N111135 P1P143812-2 1/2 1,315 1,242 1,126 5,000 1,2891 NII.1B5 P1P381258-2 5,82 1,400 1,295 1,178 N12136 P1P143812-2 j 1/2 6,000 1,441 1,361 1,23 N112.111136 P1P381258-2 5182 1,533 1,420 VALUES SHOWN ARE ALLOWABLE STRESS DESIGN (ASD). CAPACITIES DERIVED IN CONFORMANCE WITH ASCE-7 AND AC1318, APPENDIX D. USE DETAIL"A'. ANCHORAGE DESIGNATION BASED ON MINIMUM 6 SPACING. TO THE NEAREST SOLITARY INSERT OR NEAREST PAIR OF DUAL INSERTS. IN-LINE CAPACITIES SHOWN. USE 980 LBS MAXIMUM FOR BRACKET ROTATED TO ANY ANGLE ABOUT MOUNTING BOLT. DUAL BLUE BANGER HANGER "PIP" INSERT SEISMIC BRACE CONNECTION IN FORM POUR SLAB Ve Rev. 2 P.. E4710 International Seismic Application Technology 14848 11/01/15 Northam Street, La Mirada, CA 90638 877-999-4728 (Tall Free) 714-523-0845 (fax) Page J www.,satsb.com 920 A Division of Tomarco Contractor Specialties U I. PIP HEAD STAMP EDGE OF SLAB OR SLAB OPENING EDGE DISTANCE INSERT HEIGHT NUT & WASHER (OPTIONAL) ALL THREAD ROD MIN. 3,000 PSI \ NORMAL WEIGHT CONCRETE 5 1/2" MINIMUM CONCRETE : • THICKNESS .1 BLUE BANGER PIP 1YP. MAX. 15 DEG. OFF ANGLE ALLOWED WITHOUT CAPACITY REDUCTION Blue Banger Hanger Poured-In-Place (PIP) Insert Seismically Qualified for Anchorage In Cracked Concrete Seismic Design Categories C, D, E and F ICC Report No. ESR-3599 (November, 2015), Table I Deck Al Thread Rod Dia. Maximum Tension Value Nominal Minimum Insert See Page HI or 1-1I.1 At Minim urn Concrete Strength Insert Edge Minimum 3,000 psi 4,000 psi 5,000 psi 6,000 psi Part No. For Design Values Height Distance Spacing Inch Lbs Lbs Lbs Lbs Inch Inch Inch P1P143812-2 1/4,3/8,1/2 1,230 1,425 1,590 1,740 2 6 6 P1P381258-2 3/8,1/2,5/8 1,310 1,515 1,690 1,855 P1P5834-2 518,3/4 1,230 1,425 1,590 7/8, 1 wl Rod Coupler 1,740 VALUES SHOWN ARE EXCLUSIVE OF THREADED ROD CAPACITY. ROD LOCATIONS WITH SINGLE, RIGID BRACE CONNECTIONS REQUIRE ADDITIONAL SEISMIC LOAD CONSIDERATIONS BEFORE APPLYING THE ABOVE VALUES. REFER TO PROJECT SPECIFIC ISAT BRACING LEGEND. THIS LOAD INCREASE DOES NOT APPLY TO CABLE BRACES OR WHERE TWO RIGID BRACES CONNECTED TO A COMMON ROD ARE INSTALLED IN OPPOSING DIRECTIONS. VALUES SHOWN ARE ALLOWABLE STRESS DESIGN (ASD). SINGLE BLUE BANGER HANGER PIP INSERT VERTICAL SUPPORT CONNECTION Rev. 2 I International Seismic Application Technology I 11/01/15 S4710 14848 Northam Street, La Mirada, CA 90638 I 877-999-4728 (roll Free) 714-523-0845 (fax) I Page Uc ', I www.isatsb.com I G5. lB f I A Division of Tomarco Contractor Specialties \ 10I EDGE :I T DISTANCfl . : j- EDGE OF SLAB OR PIP HEAD STAMP a 4 SLAB OPENING .... .a. ..•. .0•• HI INSERT V 44 S a •iIII. HEIGHT MIN. 3,000 PSI NORMAL WEIGHT CONCRETE 510 FNIMUM— •.•. ),I. •:.. CONCRETE THI1NESS MIN. 1/2' AIR ROD WITH COUPLERJ OR HEX NIJ1TYP. WI FLAT WASHER HEX NUT, STRUT NUT, 114 IRK. xl 5/8 SO. STEEL WSHER. VERTICAL SUPPORT ALL THREAD ROD BLUE BANGER PIP AIR ROD WITH HEX NUT INSERT TYP. AND FLAT WASHER x1 518'x12GAx1'40' rt SOLID STRUT WITH 9I16HOLES 112M1N. COPE STRUT TO ALLOW 4—± 2' MAX. OFFSET DETAIL B FASTENING TOOL CLEARANCE Blue Banger Hanger Poured-In-Place (PIP) Insert Seismically Qualified for Anchorage In Cracked Concrete Seismic Design Categories C, 0, E and F ICC Report No. ESR-3599 (November, 2015), Table I Deck Two Anchor Connection Nominal Minimum Insert Tension Design Value Lbs. 1, 2,3 Insert Edge Part No. Vertical Support Rod Max. Offset Height Distance From C. L. C.L. ± 0" C.L. ± 1" C.L. ± 2" Inch Inch P1P143812-2 1,900 1,975 PlP5834-2 4 1,734 2 6 P1P381258-2 VALUES SHOWN ARE ALLOWABLE STRESS DESIGN (ASD) AND ARE EXCLUSIVE OF THREADED ROD CAPACITY. CAPACITIES ARE THE SAME FOR ALL CONCRETE STRENGTHS > 3,000 PSI. MAINTAIN 6" MINIMUM SPACING BETWEEN ADJACENT PAIRS OF INSERTS USE DETAIL "B". ROD LOCA11ONS WITH SINGLE, RIGID BRACE CONNECTIONS REQUIRE ADDITIONAL SEISMIC LOAD CONSIDERATIONS BEFORE APPLYING THE ABOVE VALUES. REFER TO PROJECT SPECIFIC ISAT BRACING LEGEND. THIS LOAD INCREASE DOES NOT APPLY TO CABLE BRACES OR WHERE TWO RIGID BRACES CONNECTED TO A COMMON ROD ARE INSTALLED IN OPPOSING DIRECTIONS. DUAL BLUE BANGER HANGER PIP INSERT VERTICAL SUPPORT CONNECTION Rev. 2 International Seismic Application Technology 11/01/15 S4710 877-999-4728 (Toll Free) 714-523-0845 (fax) Page 14848 Northam Street, La Mirada, CA 90638 UCT/ A Division of Tomarco Contractor Specialties www.isatsb.com G5.2B FORM POUR OR POST TENSIONED SLAB MINIMUM MINIMUM 3,000 PSI NORMAL WEIGHT CONCRETE —EDGE 101 +/-1t2 101 DISTANCE I 5-1/2' MINIMUM CONCRETE THICKNESS PIP DECK INSERT (TYP.) 1 50BACK BACK 5/8'X15/8'X12GA STRUT SOLID X 1'0' HOLE DIA = ATR DIA + 1/16' AIR, SQUARE WASHER AND HEX NUT (SEE CHART BELOW) PIPE COUPLING FIlTrING, PAGE H3.1. THREADED ROD MATCH WITH VERTICAL ROD DIA. Blue Banger Hanger Poured-In-Place (PIP) Insert Seismically Qualified for Anchorage In Cracked Concrete Seismic Design Categories C, D, E and F ICC Report No. ESR-3599 (November, 2015), Table I Two Insert Connection 1,2, 3,4.6 Vertical Support Rod Max. Offset From C.L. All Minimum C.L+I.O' C.L.+I-1" C.L+!-2" C.L+I-3' C.L.+I- 4" Deck Thread Mimimum Distance Tension Tension Tension Tension Tension Insert Rod Die Edge Between Design Design Design Design Design Part No. (ATR) Distance Inserts Value Value Value Value Value Inch Inch Inch Lbs Lbs Lbs Lbs Lbs PIP 143812 1/2 6 9 2,277 1,881 1,602 1,396 1,236 PIP 381258 1/2 6 9 2,382 1,967 1,676 1,4605 1,293 VALUES SHOWN ARE ALLOWABLE STRESS DESIGN (ASD) AND ARE EXCLUSIVE OF THREADED ROD CAPACITY. CAPACITIES ARE THE SAME FOR ALL CONCRETE STRENGTHS > 3,000 PSI. MAY BE LIMITED BY ROD STRENGTH, PAGE Hi OR STRUT NUT PULL-OUT STRENGTH, PAGE H3.2. MAINTAIN 6" MINIMUM SPACING BE1WEEN ADJACENT PAIRS OF INSERTS USE DETAIL "A". ROD LOCATIONS WITH SINGLE, RIGID BRACE CONNECTIONS REQUIRE ADDITIONAL SEISMIC LOAD CONSIDERATIONS BEFORE APPLYING THE ABOVE VALUES. REFER TO PROJECT SPECIFIC ISAT THIS LOAD INCREASE DOES NOT APPLY TO CABLE BRACES OR WHERE TWO RIGID BRACES CONNECTED TO A COMMON ROD ARE INSTALLED IN OPPOSING DIRECTIONS. DUAL BLUE BANGER HANGER PIP INSERT VERTICAL SUPPORT CONNECTION S4710 ' ';9 1 mfsff A Division of Tomarco Contractor Specialties International Seismic Application Technology 14848 Northam Street, La Mirada, CA 90638 877-999-4728 (Toll Free) 714-523-0845 (fax) www.isatsb.com Rev. I 11/01/15 Page G5.3B Comoonent of State of c®US USnD Fig. 909 - No-Thread Swivel Sway Brace Attachment Size Range - 1" bracing pipe. For brace pipe sizes larger than 1 use TOLCO Fig. 980. Material - Carbon Steel, hardened cone point engaging screw Function - The structural component of a sway and seismic bracing system. Features - This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. No threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. Application Note - The Fig. 909 is used in conjunction with the TOLCO Fig. 1000, Fig. 1001, Fig. 4 (A) or Fig. 4L pipe clamp, and joined together with bracing pipe. Sway brace assemblies are intend- ed to be installed in accordance with NFPA 13 (or TOLCO State of California OSHPD Approved Seismic Restraint Manual) and the manufacturer's installation instructions. The required type, number and size of fasteners used for the structure attachment fitting shall be in accordance with NFPA 13 and/or OSHPD. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions - The Fig. 909 is the structural or transi- tional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 4A, 4B or 4L to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 909 onto the bracing pipe. Tighten the set bolt until head bottoms out on surface. Attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in Electro-Galvanized and HOG finish. Order By - Figure number, pipe size and finish. Dimensions • Weiahts Pipe Size A B H* Load Lbs. Lbs. wlWasher WtJ100 1 6 1% 17/32 2015 2765 91 * Available with hole sizes to accommodate up to 3/4" fastener. Consult Factory. TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 461 Fig. 1001 - Sway Brace Attachment Size Range - Pipe size to be braced: 21h" thru 8" IPS.* Pipe size used for bracing: 1" and 11/4" Schedule 40 IPS. C®US LISTED Component of State of California OSHPD Approved Seismic Restraints System Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: The Fig. 1001 is used in conjunction with a TOLCOTM 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features - Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unneces- sary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installa- tion. See installation note below. unstauuaiion Note - i'osmon 11g. 1 UUi over me pipe TO De braced and tighten two hex head cone point set bolts until heads I Maximum Design Load I bottom out. A minimum of 1" pipe extension is recommended. I Sch 7 - 1600 lbs. I Brace pipe can be installed on top or bottom of pipe to be braced. I Sch 10 & 40 w/1" Brace Pipe - 2015 lbs. I Approvals - Underwriters Laboratories Listed in the USA (UL) Sch 10 & 40 w/1¼" Brace Pipe - 2765 lbs. and Canada(eliLi Included in our SeismicRestraints Cthlon approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note - The Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 1001 must be used only with other TOLCO bracing products. The Fig 1001 is not intended for use with the Fig. 907 4-Way Longitudinal Brace Attachment. NATIONAL AND INTERNATIONAL PATENT APPLICATION IN PROCESS OFFICE/MANUFACTURING FACILI1Y • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 1000 - "Fast Clamp" Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Size Range - Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 11/4" Schedule 40 lPS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation - The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete bracing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install - Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Maximum Design Load 1" thru 4" pipe size - 2015 lbs. 6" size - 1265 lbs. FM Approved Design Loads* 1" - 21/2" - 600 lbs 3" - 4" - 700 lbs. TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACIUTY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Longitudinal Brace Fig. 4L Longitudinal "In-Line" Sway Brace Attachment Size Range - 2" through 8" IPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Approvals - Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) 2" - 8". Approved by Factory Mutual Engineering (FM), 21/2" - 8" pipe. Installation Instructions - The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, pipe size and finish. 4-Way Riser Brace (Plan view) Dimensions • Weights Bolt Max. Rec. *Max Rec. Approx. Sizes A C D Size Load Lbs. Load Lbs. WtJ100 (cULus) (FM) 21h 67/16 21h 23/4 1/2 2015 3000 253 3 7 23/4 31A6 1/2 2015 1550 268 4 81h 33A 311A6 1/2 2015 1550 348 5 91% 3/8 43A 1/2 2015 1450 380 6 11½ 5 51/8 1/2 2015 1450 640 8 131/4 5% 5% 1/2 2015 1450 728 * Load shown is allowable with brace installed, between 300 - 900. No reduction of load based on brace angle is required. FM approved when used with 1, 11/4 , 1½ or 2' Sch. 40 brace pipe. TOLCO® brand bracing components are designed to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH: 951.737.5599 • FM: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com (E)POTTER The Symbol of Protection U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50mm thru 200mm). LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die- cast housing. The cover is held in place with two tamper resis- tant screws which require a special key for removal. A field in- stallable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD UL,ULCandCSFMListed, FMandLPCBApproved,NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI (31 BAR) Minimum Flow Rate forAlarm: 10 GPM (38 LPM) Maximum Surge: 18 FPS (5,5 m/s) ContactRatings: Two sets of SPOT (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA 4/11354 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/1200F, 4,50C/490C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF.. Service Use: Automatic Sprinkler NFPA-1 3 One or two family dwelling NFPA-1 30 Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be in- stalled within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a dis- tance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8800001 - REV W PAGE 1 OF 2 MFG. #5400761 - 7/02 Page 72 FlG.4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. OWE. 0761-4 (E)POTTER The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME FIG. I SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL cI5 ON. 1023-3 CAUTION: An uninsulated section of a single conductor should not be looped around the termi- nal and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG.2 OPTIONAL TAMPER SWITCH RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS. A "B" SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO "B". TO INSTALL, DRILL HOLE AS INDICATED: PIPE SIZE HOLE SIZE to 2 1/2" 1 1/4" +1/8" -1/16" (50n1n1 to 65mm) (33n1nr ±2mm) to 8' 2' ±1/8' (80mm to 200mm) 50mm ±2mm) Cover Tamper (with cover in place) in WATERFLOW DIRECTION OF C NO NC (WHI) (RED) (61.0) ' IS1H-2 DWG. #761 -30 TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL 50FT.-LBS (68 ri-rn) OF TORQUE MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) 0 0 A 10-25 B 20-40 C 35-55 5 50-70 E 60-90 FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: The Model VSR-F has two switches, one can be used to 2 SETS OF _________________ operate a central station, pro- NORMALLY OPEN CONTACTS CLOSE OR AUOU CRFLON ZONE (AIR FROM ON ONE PAWL prietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. I I'I E1 A condition of LPC Approval of 00 POSITIVE this product is that the electri- THE NC AND NO MOOIONOS ON THE SWITCH ME FOR OR CT AC nz cal entry must be sealed to AN ALARM CONDITION. THE CONTACTS ME REVERSED DC NEOAII'JE OR NEUTRAL AC_ exclude moisture. WHEN TIlE OCOCE A IN THE NORMAL COTOSTEN. DWO I761.2 For supervised circuits see "Switch Terminal Connec- tions" drawing and caution note (Fig. 1). APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. 98800001 - REV PAGE 2 OF 2 MFG. #5400761 - 7/02 Page 73 Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -300 to 150°F (-340 to 660C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. SIZE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENT TYPICAL dB AT 10 FT. (3m) (2) MINIMUM dB AT1OFI (3m) (1) 6(150) 12VDC PBD126 1706012 .12A 85 76 8(200) 12VDC PBD128 1708012 .12A 90 77 10(250) 12VDC PBD1210 1710012 .12* 92 78 6(150) 24VDC PBD246 1706024 .06* 87 77 8(200) 24VDC PB0248 1708024 .06A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 80 6(150) 24VAC PBA246 1808024 .17* 91 78 8(200) 24VAC PBA248 1808024 .17* 94 77 10(250) 24VAC PBA2410 1810024 .17A 94 78 6(150) 120VAC PBA1206 1806120 .05A 92 83 8(200) 120VAC PBA1208 1808120 .05* 99 84 10(250) 120VAC PBA12010 1810120 .05A 99 86 (E)POTTER The Symbol of Protection 6" BELL SHOWN BELLS PBA-AC & PBD-DC UL Listed Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC -> 12OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 wv.pottersignal.com PRINTED IN USA MKT. #8850001 - REVS PAGE 1 OF 2 MFG. #5400776 - 5/05 Page 74 (E)POTTER The Symbol of Protection BELLS PBA-AC & PBD-DC DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 1/2 CONDUIT ENTRANCE 1 /7 - 10" <250> (200) 6" _LF' 2 11/16" DWG. #776-I (68) 5 3/4- (146) i_T_j 15/8 (41) OWG. #776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) CREO WHITE (IN) WHITE (OUT) OR -UNE OR 0 TO OR FROM CONTROL PMEL ([ ELL FROM CONTROL PANEL !CK (OUT) R PRECEDING BELL PRECEDING BELL _____________ BLACK (IN) _______BLACK (IN) _______ CAUTION WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: OBSERVE POLARITY TO RING D.C. BELLS. RED WIRES POSITIVE (+) BLACK WIRES NEGATIVE (-) CAUTION WHEN ELECTRICAL SUPERVISION IS REOUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: WHEN USING A.C. BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL END-OF-LINE RESISTOR IS NOT REQUIRED ON A.C. BELLS. DWG. #776-3 INSTALLATION The bell shall be installed in accordance with NFPA 72 or local Ahj. The top of the device shall be no less than 90" Aff and not less than 611 below the ceiling. Removethegong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REVS PAGE 2 OF 2 MFG. #5400776 - 5/05 Page 75 Technical Data Model: Sprinkler Head Cabinet Style: 3, 6 or 12 head Standard Finish: Red enamel Mfgr. Source: Non-domestic Capacity: 3 sprinkler heads 6 sprinkler heads 12 sprinkler heads Dimensions: 3 head - 5" high x 7W long x 2%" deep 6 head -5" high x 14" long x 3W deep 12 head - 5" high x 14Y4" long x 5" deep Weight: 3 head - 1.5 lbs. 6 head - 2.3 lbs. 12 head-4 lbs. 3or 6 & 12 Head Sprinkler Head Cabinet Sprinkler Head Cabinet Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product Description Central Sprinkler Head Cabinets are constructed of a metal enclosure with a hinged cover designed to provide on-site storage of an emergency supply of sprinkler heads and a sprinkler head wrench. NFPA 13 requires a representative number of each type of sprinkler head used in a sprinkler system to be stored in a cabinet on-site to allow for immediate removal and replacement of sprinklers which may have operated or become damaged. Central Sprinkler Head Cabinets are manufactured of heavy gauge steel with knock-outs to accommodate either W' or %" N.P.T. threaded sprinkler heads and are painted an attractive red enamel. They are available in three (3), six (6) or twelve (12) head capacity. Page 76 No. 28.6.0 INTUMESCENT SEALANT APPLICATIONS Specseal® LCI Sealant has a broad application base designed to seal a wide variety of common penetrations in light commercial and grouped residential construction. Penetrant types include insulated and non-insulated metallic pipes and tubes, non-metallic pipes and tubes, and common electrical service and power distribution, telephone, data, and TV cabling. This product is also used in conjunction with other SpecSeal® Products such as SpecSeal® Firestop Collars and Wrap Strips to protect larger plastic pipes. See Table A for a summary application list. PRODUCT DESCRIPTION SpecSeal® LCI Sealant is a versatile and economical intumescent product intended for firestopping a wide array of applications in small commercial or grouped residential construction and other structures with similar applications. SpecSeal® LCI Sealant is available in a single grade that has excellent caulk- ing properties as well as high build properties on vertical or overhead surfaces. This single grade may be caulked (standard cartridge or bulk loaded), knifed or troweled. In addition, SpecSeal® LCI Sealant does not contain PCB's or asbestos. SpecSeal® LCI Sealant is storage stable (when stored according to the manufacturer's recommenda- tions), and will not separate or shrink when dried. SpecSeal® Series LCI Sealant will adhere to all com- mon construction and penetrant materials and contains no solvents that might adversely effect plastic pipes or cable jackets. Economical: High performance without the high price! Highly Intumescent: Expands up to 8 times. Excellent Smoke Seal Water Resistant: Will not re-emulsify when dry. Water-Based for easy installation, cleanup, and disposal. Acoustically Tested: Reduces noise transmission Safe ... Low VOC's, No Solvents, Non-Halogehated Paintable PERFORMANCE SpeeSeal® LCI Sealant is the basis for systems that meet the exacting criteria of ASTM E814 (UL1479) and ASTM E1966 (UL2079) as well as to the time-temperature requirements of ASTM E119 (U1263). LCI provides up to a 2-hour fire rating for typical service penetrations through concrete or wood floors, concrete or masonry walls, as well as gypsum board walls (3-hour for metallic pipe, conduit and tubing). SpecSeal® LCI Sealant meets Class A finish requirements for Flame Spread and Smoke Development when tested in accordance with ASTM E84 (UL723). SpecSeal® LCI Sealant is also acoustically tested, demonstrating excellent sound attenuation properties. PHYSICAL PROPERTIES SYSTEM COMPATIBLE Color Red Odor Mild Latex Density 9.0 lb/gal (1.08 kA) pH 9.0 In Service Temperature .~ 130'F (54°C) Flame Spread 0* Smoke Developed 5' SIC Rating 62 (ASTM E90IASTM 9I9) VOC Content 0291ts 0g&) (EPA Method 24/ASTM D60l Shelf Life 2yrs Volume Expansion lox Free Expansion Storage Temp. ~130°F(54°C) TbASME84(JtJ23)at14%sawlndtedstho sodantsaodisl 411.01% FILL, VOID OR CAVITY MATERIALS FOR USE IN JOINT SYSTEMS AND THROUGH-PENETRATION F1RESTOP c® us SYSTEMS. SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY. I APPROVED SPECIFICATIONS The firestopping sealant shall be a water-resistant, intumescent latex sealant. The sealant when exposed to high heat or flame shall exhibit a free expansion of up to 8 times its original volume. The firestopping sealant shall contain no water soluble nor hygroscopic ingredients and shall be acoustically tested. The sealant shall be UL Classified and/or FM approved and tested to the requirements of ASTM E814 (UL1479) and shall meet Class A finish requirements when tested in accordance with ASTM E84 (UL723). SPECIFIED DIVISIONS DIV. 7 07840 Through-Penetration Firestopping DIV. 13 13900 Special Construction Fire Suppression & Supervisory Systems DIV. 15 15250 Mechanical Insulation - Fire Protection DIV. 16 16050 Basic Electrical Materials & Methods 96 Technical Service 18009921180 511 Product Data Sheet • Series 1(1 Intumescent Sealant • FOD-5062 06/2007 9T-1. www.stifirestop.com Fig 1: METALLIC PIPES - Concrete!?Iasoniy Floors & Walls Fig 2: INSULATED METALLIC PIPES- ConcretelMasonry Floors & Walls Steel Sleeve Metallic LCI Pipe Sealant 1[ LCI Metallic Pipe eaIant LCI Sealant Mine ii LCI Sealant St.el Concrete slam Roar ________ wool steel Concrete (Both Sides) 11 Sleeve Floor Mineral Wool _______________ Mineral 1 Weal : oncrate Wall Pipe ulatted Wall Aesembly Metallic Pipe UL System No. C-AJ-1353 UL System No. W-J-1098 UL System No. C-AJ-5138 F Rating: 3Hr.T Raft OHr F Raft 2Hr.T Rating: 114,3I4&1Hr F Rating: 2Hr.T Rating: 3/4orl Hr SIW or Iron Pipe: <12", Copper Pce:<4° Stor Iron Piz 8°,CoppePpe:<4" Steel ar Iron Poe: 6, Copper Pe:4 Annulus: 0" 1o2" Annul' 102" Pe Covering: Max 2lber glass mineral wod pipebtsulaton. Sealant Depth: 114' Sealant Depth: 55" Annulus: 1W to 1-55'• Sealant: 112" a gMaterial: Nom 4f nhiest wool (2 IN 'Depth) Fonntng: Nan. 4 p mineral wool (3"lh) Pipe size Diameter of Opening (in.) 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10 12 14 26 Irade Pipe Size 0.11 0.51, 0.840 0.3 0.6 1.6 3.0 4.8 6.9 9.5 12.4 19.5 28.1 38.3 132.6 .0fisentSubd Depth? 1.315 0.1 0.4 1.4 2.8 4.6 6.7 9.3 12.2 19.3 27.9 38.1 132.4 IS' MutpLy2 1.5" 1.900 1.1 2.4 4.2 6.4 8.9 11.9 18.9 27.6 37.8 132.0 58 Mutplyby2 r MuSply4 2.375 0.7 2.0 3.8 6.0 8.5 11.5 18.5 27.2 37.4 131.6 2.5" 2.875 0.1 1.5 3.3 5.4 8.0 10.9 18.0 26.7 36.9 131.1 MubplyLy5 3.500 0.7 2.5 4.7 7.2 10.2 17.2 25.9 36.1 130.3 3.5" 4.000 1.8 3.9 6.5 9.4 16.5 25.1 35.3 129.6 4.500 0.8 3.0 5.6 8.5 15.6 24.2 34.4 128.7 6" 6.625 1.1 4.0 11.1 19.7 29.9 124.2 8" 8.625 4.9 13.6 23.8 118.0 10" 10.750 5.6 15.8 110.0 12" 12.750 6.6 100.8 24" 24.000 19.6 IMPORTANT NOTE: This table is for estimation purposes only. Cessuft UL Fire Resistance Directory or 511 Product &Application Guide for spesitu installation requirements and tmilationo Fig. 3: ELECTRICAL, DATA OR COMMUNICATIONS - Gypsum Walls Cable LCI Sealant LCI Sealant Bundle (Both Sides) Non-Metallic (Both Sides) ConduIt FE Gy sum Assembly urn ffl Wal?board Walaard Assembly UL System No. W-L-3169 UL System No. W-L-2241 F Rating: 1,2Hr•T Rating: 1Aand3/4 F Rating: 12Hr.T Rating: 0,1411-3/4 Up to 4-V2-cable bundle <2" Rigid PVC orENM1 CPVC, ABS Annulus: 0-to A"- Sealant: 5(8" Annulus: 0-1"- Sealant 5/8" 511 Product Data Sheet • Series ICI Intumescent Sealant • FOD-5062 06/2007 TABLE A: APPLICATIONS TESTED AND CLASSIFIED FOR FIRE RESISTANCE Metallic Pipes including steel, iron, or copper pipe and tubing. Nonmetallic Pipes, Conduits & Tubing including PVC, CPVC, ABS, and PEX. Electrical & Electronic Cabling including service entrance, power distribution, computer, telephone, and television. Metal Ductwork including HVAC, bath and dryer vents. Insulated Pipes including heating, cooling, and condensation applications. Complete Wood Floor firestopping package for electrical, plumbing, HVAC, telephone, and television. Technical Service 1-800-992-1180 Mi www.stifirestop.com STI. I Fig. 4: BARE & INSULATED METALLIC PIPES- Wood Floor Assemblies I Metallic Pipe ..j1 LCI Sealant LCI Sealant Insulated Metallic Pipe Wood Floor Sealant LCI Wood Floor Assembly Sealant Assembly UL System No. F-C-1074 F Rating: 1 & 2 Hr • I Rating: ¼, ½ and 1 Hr Steel, Iron or Copper: 4"• Chase wall optional. Annulus: 0-to 1"•Sealant: 5/8-bottom, 3/4-top UL System No. F-C-5043 F Rating: 1 & 2 Hr - I Rating: 3/4 and 1 Hr Steel, Iron or Copper: 4" Pipe covering: 1 "Fiber Glass, Mineral fiber or AB/PVC • Chase wall optional. Annulus: 0t0 1"•Sealant: 5/8- bottom, V4'top. INSTALLATION INSTRUCTIONS GENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Installation temperatures must be between 35°F (2°C) and 100°F (380C). Allow product to dry a minimum of 24 hours before exposure to moisture. SYSTEM SELECTION: Selection of an appropriate firestop system design is critical to the fire protection process. Space limitations preclude highly detailed information pertaining to individual application systems. Please consult the Product & Application Guide as well as the UL® Fire Resistance Directory for additional information. FORMING: Some installations may require forming as either an integral part of the system or as an option to facilitate installation. In systems where forming is required, mineral wool balls with a minimum nominal density of 4 PCF (64 kg/ml) are generally required. Cut forming material oversize to allow for tight packing. Position forming material to allow for the proper depth of fill material. FILL MATERIAL: SpecSeal® LCI Sealant may be installed by caulking using a standard caulking gun or from bulk containers using a bulk loading caulk gun, or by manually troweling using a mason's trowel or putty knife. If the sealant tends to pull back from a surface, clean the surface with a damp rag or sponge and reapply. Work sealant into all areas exercising care to eliminate voids or seams. The surface of the sealant can be smoothed using a putty knife dipped in water. Adding water to the sealant itself is not recommended. Sealant (when dry) may be painted using most non-solvent based paints. I Fig. 5: BARE & INSULATED METALLIC PIPES- Gypsum Walls In gypsum wallboard penetrations, apply a minimum cove bead of 1/4 (6 mm) at the interface of the penetrant with both exterior wall surfaces. SMOKE SEALING: In some applications including firestop collars, SpecSeal® LCI Sealant is recommended as a smoke seal. It is suggested in these applications that the sealant be applied to both sides of walls. In floor applications, a sealing bead is suggested top and bottom. LIMITATIONS: SpecSeal® LCI Sealant is water- based and cures through the evaporation of water. Low temperatures as well as high humidity may retard drying. Non-porous or impermeable backing materials, plates, or coatings may retard the drying process. Do not paint or seal in any way that pre- vents contact with air until sealant has dried through completely. This product has been designed to be sate with plastics and has been used extensively and successfully with avadety of different types of plastic pipes, tubes, and plastic cable insulations. Variations in these materials however, make it impossible to guarantee compatibility. STI strongly recommends that the user consult with the manufacturer of the pipe, tubing, or cable in question regarding any known sensitivities or potential restrictions before applying this product. UL System No. W-L-1222 F Rating: 1,2 Hr • I Rating: 1/4, 3/4, 1 Hr Steel or Iron pipe: 8' Copper pipe: 4" Annulus: 0-to 2"• Sealant: 5/8" Insulated I I III LCI Sealant Metallic III (Both Mae) Gypsum Wallboard fu Assembly UL System Nos. W-L-5121, W-L.-5122 F Rating: 1,2 Hr.lRating: 1 Hr& 1/4 Hr Steel or Iron pipe: 6 Copper pipe: 4" Pipe covering: Max. 2-fiber glass, V4-AB/PVC or 2minera1 fiber Annulus: 0t0 1-1/2• Sealant 5/8" LCI Sealant (Both Sides) AC Line Set UL System No. W-L-8025 F Rating: 1,2 Hr • I Rating: ¼ Hr AC Line Set: Two copper tubes, one with 3/4-AB/PVC and thermostat wire Annulus: 0-to 1 -- Sealant 5/8" 96 STI. Technical Service 1-800-9921180 511 Product Data Sheet • Series ICI Intumescent Sealant • FOD-5062 06/2007 www.stifirestop.com CAT. NO. DESCRIPTION LC1300 Sealant 10.1 oz Tube 18.2 Cu In (300 ml) 1C1305 Sealant 5 Gal Pail 1,155 Cu In (19.0 Liters) LC1320 Sealant 20 oz Sausage 36 Cu in. (592 ml) LC1329 Sealant 29 oz Quart Tube 52 Cu in. (858 ml) MAINTENANCE No maintenance is normally required, however a periodic inspection of rated bafflers is recommended to make sure that any new openings, modifications of previously installed firestops, or areas exhibiting physical damage, have been properly sealed or repaired. Subsequent sealing or repairs should be accomplished using SpecSeal® products per the original approved design. RETROFIT: When adding or removing penetrants, care should be taken to minimize damage to the seal. Reseal using SpecSeat® products per the approved design. NOTE: New penetrants of a different nature than the original design may require a totally new firestop design or extensive modifications to the existing design. Reseal all openings as per the requirements of the modified design. TECHNICAL SERVICE Specified Technologies Inc. provides toll free technical support to assist in product selection and appropriate installation design. UL Systems, Material Safety Data Sheets and other technical information is available through the Technical Library at www.stitiresInp.com. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional information on the safe handling and disposal of this material. AVAILABILITY SpecSeal® Series LCI Sealant is available from authorized STI distributors. Consult factory or website for the names and locations of the nearest sales representatives or distributors. SettesSSS Sealant The industry's most versatile sealant provides the firestopping solutions for a wide range of combustible and noncombustible applications. Water-based intumescent sealant expands up to 8X! lnflireaspSthps Three grades of intumescent wrap strips provide an unmatched combination of flexibility, economy, and expansion (up to 30X). Systems for plastic pipes including FR Polypropylene up 108" trade size! SSC&LcCflrestopcollars Easy to install, economical protection for ABS and PVC pipes (both solid and foam core) as well as CPVC, PVDF, and FRPP. LCC Collars are available up 104" and SSC Collars are avail- able up 106" trade size. Flrestop Mortar Lightweight, versatile and economical! The best choice for large or complex installations. SSP Flrestop Putty Available both in bar form and in pads, putty provides easy retrofit for through-penetradons and economical protection for electrical boxes. PencIl® Silicones Sealants and loam for through-penetrations and construction joints. Unexcelled aging charac- teristics and flexibility. Ebastomerlc Joint Seals New economical products for sealing construction joints. Choose caulk or spray applied products tested to UL2079. CITY OF NEW YORK MEA 211-01-M IMPORTANT NOTICE: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy and completeness thereof is not guaranteed. WARRANTY Specified Technologies Incmanufactures its goods in a manner to be free of defects. Should any defect occur in its goods (within one year), Specified Technologies Inc., upon prompt notification, will at its option, exchange or repair the goods or refund the purchase price. LIMITATIONS AND EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT USE No statement or recommendation not contained herein shall have any force or effect unless in an agreement signed by officers of sailer and manufacturer. MADE IN THE USA - COPYRIGHT © 2008 SPECIFIED TECHNOLOGIES, INC. Specified Technologies Inc. Sm 200 Evans Way. Somerville, NJ 08876 I Toll Free: 800-992-1180 • F: 908.526.9623 4 511 Produd Data Sheet • Series LCI Intumescent Sealant • FOD.5062 06/2007 Technical Service 1-800-992-1180 99 www.stifirestop.com Sill. Guide XHEZ (W-L-1222 - B Card) Through-Penetration Firestop Systems (Cont'd from W-L-1222 - A Card) System No. W-L-1 222 October 04, 2000 F Ratings - I and 2 Hr (See Item 1) T Ratings - 1/4, 3/4 and 1 Hr (See Item 2) 1. Wall Assembly - The I or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be mm 3-5/8 in. wide and spaced max 24 in. OC. Gypsum Board* - Thickness, type, number of layers and fasteners as specified in the individual Wall and Partition Design. Max diam of opening is 10-5/8 in. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant - One metallic pipe, conduit or tube to be installed eccentrically or concentrically within the firestop system. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min o in. (point contact) to max 2 in. Pipe, conduit or tube to be rigidly supported on both sides of the wall assembly. The following types and sizes of metallic pipes, conduits and tubes may be used: Steel Pipe - Nom 8 in. diam (or smaller) Schedule 5 (or heavier) steel pipe. Iron Pipe - Nom 8 in. diam (or smaller) cast or ductile iron pipe. Conduit - Nom 6 in. diam (or smaller) rigid steel conduit, nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT) or nom 4 in. diam (or smaller) flexible steel conduit. Copper Pipe - Nom 4 in. diam (or smaller) Regular (or heavier) copper pipe. Copper Tube - Nom 4 in. diam (or smaller) Type L (or heavier) copper tube. Type of Penetrant Max Diam T Rating Steel or iron pipe, steel conduit or EMT 2 in. 1 hr Steel or iron pipe, steel conduit or EMT 8 in. 3/4 hr Copper pipe or tube 4 in. 1/4 hr 2A. Through Penetrating Product* - Flexible Metal Piping - As an alternate to Item 2, one nom 1-1/4 in. diam (or smaller) steel flexible metal pipe to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe and the periphery of the opening shall be min 0 in. (point contact) to max 2 in. Pipe to be rigidly supported on both sides of the wall assembly. OMEGA FLEX INC TITEFLEX CORP ABUNDYCO WARD MFG INC 3. Fill, Void or Cavity Material* - Sealant - Mm 5/8 in. thickness of fill material applied within annulus, flush with both surfaces of wall assembly. At point contact location, mm 1/4 in. diam bead of fill material applied at metallic pipe/gypsum board interface on both surfaces of wall. SPECIFIED TECHNOLOGIES INC - SpecSeal LCI Sealant *Bearing the UL Classification Marking "A Guide XHEZ October 04, 2000 Through-Penetration Firestop Systems W-L-I 222 - A Card System No. W-L-1222 F Ratings - I and 2 Hr (See Item I) T Ratings - 1/4, 314 and 1 Hr (See Item 2) Section A-A (Cont'd on W-L-1 222 - B Card) Guide XHEZ (C-AJ-1354 - B Card) Through-Penetration Firestop Systems (Cont'd from C-AJ-1 354 - A Card) System No. C-AJ-1353 November 30, 2001 F Rating —3Hr TRating — OHr 1. Floor or Wall Assembly - Mm 2-1/2 in. thick reinforced lightweight or normal weight (100- 150 pcf) concrete floor. Floor may also be constructed of any min 6 in. thick hollow-core Precast Concrete Units*. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 10 in. Max diam of opening in floors constructed of hollow- core is 7 in. See Concrete Blocks (CAZT) or Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 2. Steel Sleeve - (Optional) - Nom 10 in. diam (or smaller) Schedule 10 (or heavier) steel pipe cast or grouted into floor or wall assembly. Steel sleeve may be installed flush or may project a max 2 in. beyond the floor or wall surfaces. 3. Through Penetrant - One metallic pipe, conduit or tube to be installed eccentrically or concentrically within the firestop system. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. (point contact) to max 2 in. Pipe, conduit or tube to be rigidly supported on both sides of the floor or wall assembly. The following types and sizes of metallic pipes, conduits and tubes may be used: Steel Pipe - Nom 12 in. diam (or smaller) Schedule 5 (or heavier) steel pipe. Iron Pipe - Nom 12 in. diam (or smaller) cast or ductile iron pipe. Conduit - Nom 6 in. diam (or smaller) rigid steel conduit, nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT) or nom 4 in. diam (or smaller) flexible steel conduit. Copper Pipe - Nom 4 in. diam (or smaller) Regular (or heavier) copper pipe. Copper Tube - Nom 4 in. diam (or smaller) Regular L (or heavier) copper tube. 3A. Through Penetrating Product* - Flexible Metal Piping - As an alternate to Item 3, one nom 2 in. diam (or smaller) flexible steel pipe to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. (point contact) to max 2 in. Pipe to be rigidly supported on both sides of the floor or wall assembly. Omega Flex Inc Titeflex Corp A Bundy Co Ward Mfg Inc 4. Firestop System - The firestop system shall consist of the following: Packing Material - Min 4 pcf mineral wool batt insulation compressed and tightly packed to mm 2-1/4 in. thickness. Packing material recessed from top surface of floor or both surfaces of wall as required to accommodate fill material (Item 413). In floors constructed of hollow-core precast concrete units, packing material to be recessed from both top and bottom surfaces of floor, as required to accommodate fill material (Item 413). When steel sleeve projects from top of floor or from both sides of wall, the thickness of mineral wool batt packing material should be increased by an amount equal to the distance that the sleeve extends past the floor or wall surface. Fill, Void or Cavity Material* - Sealant - Mm 1/4 in. thickness of fill material applied within annulus, flush with top surface of floor assembly or top edge of steel sleeve. In walls, mm 1/4 in. thickness of fill material applied flush with both surfaces of wall assembly or both ends of steel sleeve. In floors constructed of hollow-core precast concrete units, fill material installed symmetrically on both side of floor. At point contact location, apply mm 1/4 in. diam bead of fill material at pipe/concrete interface or pipe/steel sleeve interface on top surface of floor or both surfaces of wall or precast concrete units. Specified Technologies Inc - SpecSeal LCI Sealant 2 -- Guide XHEZ November 30, 2001 Through-Penetration Firestop Systems C-AJ-1 353-A Card System No. C-AJ-1353 F Rating -2Hr TRating - OHr Section A-A (Cont. on C-AJ-1353-B Card)