HomeMy WebLinkAbout946 BEGONIA CT; ; AS160260; Permit9/12/23,10:02 AM 0 AS160260 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS160260 Job Address: 946 BEGONIA CT Permit Type: SPRINK Parcel No: 2143902700 Lot #: 0 Reference No.: Status: ISSUED Applied 8/18/2016 Approved: 8/25/2016 Issued: 8/25/2016 PC #: Inspector: Project Title: OLSON GUEST QUARTERS ROOMS DESIGNED WITH A SINGLE SPRINKER HEAD ARE TO BE SPACED AT 16'X 16' WITH 13.0 GPM FLOWING PER HEAD. ALL OTHER AREAS TO BE SPACED AS NOTED IN THE GENERAL NOTES ON SHEET FP-1. ALL NEW PIPES TO BE 1" CPVC PLASTIC, U.N.O. TYPICAL CEILING = 10'-0", U.O.N Applicant: Owner: OLSEN DON&BRENDA 944 BEGONIA CT CARLSBAD CA I Fees ($) Add'I Fees ($) Total ($) I Balance ($) 303 0 303 0 about:blank 1/1 City of Carlsbad 08-25-2016 Fire Department Permit Permit No: AS160260 Job Address: 946 BEGONIA CT CBAD Permit Type: SPRINK Subtype: RES Status: ISSUED Parcel No: 2143902700 Lot #: 0 Applied: 08/18/2016 Issued: 08/25/2016 Fire Dept Ref#: AS160260 Building Permit: CB152640 Entered By: AR Location: Project Title: OLSON GUEST QUARTERS Description: ROOMS DESIGNED WITH A SINGLE SPRINKER HEAD ARE TO Contractor: INNOVATIVE FIRE PROTECTION INC Phone: (619) 593-8200 STE 101 Fax: (619)593-9133 8779 COTTONWOOD AV SANTEE CA 92071 Total Fees: $303.00 Total Payments To Date: $0.00 # of Systems # of Additional Risers or Floors Plan Check Fee Additional Plan Check Fee # of Heads Permit Fee Additional Permit Fee Re-Inspection Fee ByPass Meter Fee ByPass Addtl Meter Fee Other Additional Fees TOTAL PERMIT FEES 0 $0.00 $90.00 0 $0.00 $0.00 $71.00 2 $142.00 $0.00 $0.00 $0.00 $0.00 $303.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.' You have 90 days from the date this permit was issued to pretest imposition of these fees/exactions. If you pretest them, you must follow the pretest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. flLE COPY INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR OLSEN GUEST QUARTERS 946 BEGONIA COURT CARLSBAD, CA 92011 FILE NUMBER: 06356 DATE: AUGUST 16, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose) FLOW AND PRESSURE (8 BOR): SPRINKLER ORIFICE SIZE: NAME OF CONTRACTOR: DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: CONTRACTOR CERTIFICATION NUMBER: RES IDENTIAL/LIGHT .05 gpm/sq. ft. 312 sq. ft. 14' X 14'-196 sq. ft. 2 sprinklers 22.0 gpm 27.0 gpm 22.0 gpm 8 22.0 psi 1/2" inch INNOVATIVE FIRE PROTECTION, INC. JOE PLASSMEYER SAN DIEGO FIRE DEPARTMENT C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # &CLICE& HRS SYSTEMS, INC. AS 1 60260 946 BEGONIA CT ci) .4-) 0 z SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/16/2016RAM FILES\HRS SYSTEMS\HASS86\OLSEN GUEST QUARTERS(2HD) .SDF JOB TITLE: OLSEN GUEST QUARTERS o C C C C 0 0 • • • • • - C 0 C C C C 0• 0 • H- N -O LU lw C') CN H 0 I -04U)-H--- 11 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/16/2016RAM FILES\HRS SYSTEMS\HASS86\OLSEN GUEST QUARTERS(2HD).SDF JOB TITLE: OLSEN GUEST QUARTERS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 64.0 55.0 500.0 64.0 27.0 54.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 27.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 22.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 0.0 SOURCE 54.8 27.0 2 0.0 - - - - 43.7 - - - 2A 0.0 - - - - 41.7 - - - D 2.0 - - - - 39.3 - - - C 2.0 - - - - 33.3 - - - 2B 0.0 - - - - 32.7 - - - 3A 5.0 - - - - 26.3 - - - 3B 7.0 HOSE STREAM 23.3 5.0 3 9.0 - - - - 22.0 - - - 4 11.0 - - - - 20.8 - - - 4A 11.0 - - - - 16.8 - - - 5 14.0 - - - - 14.3 - - - 6 15.0 - - - - 13.6 101 15.0 K= 3.00 13.4 11.0 102 15.0 K= 3.00 13.4 11.0 103 14.0 - - - - 14.0 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/16/2016RAM FILES\HRS SYSTEMS\HASS86\OLSEN GUEST QUARTERS(2HD).SDF JOB TITLE: OLSEN GUEST QUARTERS NFPA2 PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) Note To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 1 Source 0.0 . 50.00 150 54.8 1 0.0 54.8 27.0 2A K1.000 T: 6.0 7.00 0.0 2 0.0 43.7 27.0 0.995 G: 1.0 57.00 0.194 11.1 Pipe: 2 0.0 Fixed Pressure Loss Device 2 0.0 43.7 27.0 D 2.0 psi, 27.0 gpm 2A 0.0 41.7 27.0 Pipe: 3 0.0 0.0 3.00 150 41.7 2A 0.0 41.7 27.0 C L1.000 2E: 6.0 6.00 0.9 D 2.0 39.3 27.0 1.025 9.00 0.168 1.5 Pipe: 4 0.0 Fixed Pressure Loss Device D 2.0 39.3 27.0 2B 6.0 psi, 27.0 gpm C 2.0 33.3 27.0 Pipe: 5 0.0 0.0 3.00 150 33.3 C 2.0 .33.3 27.0 3A L1.000 2E: 6.0 6.00 -0.9 2B 0.0 32.7 27.0 1.025 9.00 0.168 1.5 Pipe: 6 0.0 0.0 150.00 150 32.7 2B 0.0 32.7 27.0 3B E1.500 2E: 8.6 8.56 2.2 3A 5.0 26.3 27.0 1.500 158.56 0.026 4.2 Pipe: 7 H.S. 5.0 Disch 3.00 150 26.3 3A 5.0 26.3 22.0 3 L1.000 E: 3.0 10.00 0.9 3B 7.0 23.3 27.0 1.025 T: 7.0 13.00 0.168 2.2 Pipe: 8 0.0 0.0 3.00 150 23.3 33 7.0 23.3 22.0 4 F1.000 E: 2.5 2.50 0.9 3 9.0 22.0 22.0 1.101 5.50 0.081 0.4 Pipe: 9 0.0 0.0 2.00 120 22.0 3 9.0 22.0 22.0 4A A1.000 ---- 0.00 0.9 4 11.0 20.8 22.0 1.049 2.00 0.155 0.3 Pipe: 10 0.0 Fixed Pressure Loss Device 4 11.0 20.8 22.0 5 4.0 psi, 22.0. gpm 4A 11.0 16.8 22.0 . Pipe: 11 0.0 11.0 102 6.00 150 16.8 4A 11.0 16.8 11.0 6 F1.000 E: 2.5 8.50 1.3 5 14.0 14.3 22.0 1.101 T: 60 14.50 0.081 1.2 Pipe: 12 0.0 0.0 6.00 150 14.3 5 14.0 14.3 11.0 101 F1.000 E: 2.5 8.50 0.4 6 •15.0 13.6 11.0 1.101 T: 6.0 14.50 0.022 0.3 DATE: 8/16/2016RAM FILES\HRS SYSTEMS\HASS86\OLSEN GUEST QUARTERS (2HD) .SDF JOB TITLE: OLSEN GUEST QUARTERS Pipe Tag K-fac Add Fl Add Fl To Fit: L C Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf!ft. Pipe: 13 3.00 11.0 Disch 15.00 150 5 14.0 14.3 0.0 Fl.000 2E: 5.0 5.00 102 15.0 13.4 11.0 1.101 20.00 0.023 Pipe: 14 3.00 11.0 Disch 1.00 150 6 15.0 13.6 0.0 F1.000 T: 6.0 6.00 101 15.0 13.4 11.0 1.101 7.00 0.022 Pipe: 15 0.0 0.0 21.00 150 103 14.0 14.0 0.0 F1.000 6E:15.0 15.00 6 15.0 13.6 0.0 1.101 36.00. 0.000 (Pt) (Pe) Not( (Pf) 14 .3 0.4 0.5 13.6 0.0 0.2 14 .0 0.4 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 NOTES (HASS) Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license, no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.007 gpm and a maximum imbalance at any node of 0.103 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 11.1 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AimChk DPVlv NPTee 1.610 4.00 8.00 2.00 9.00 6.00 1.00 10.00 10.00 8.00 INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR OLSEN GUEST QUARTERS 946 BEGONIA COURT CARLSBAD, CA 92011 FILE NUMBER: 06356 DATE: AUGUST 16, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 100 sq. ft. COVERAGE PER SPRINKLER: 16' X 16'-256 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 1 sprinkler TOTAL SPRINKLER WATER FLOW REQUIRED: 13.0 gpm TOTAL WATER REQUIRED (including hose) :• 18.0 gpm FLOW AND PRESSURE (8 BOR) : 13.0 gpm 8 15.3 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: SAN DIEGO FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # &CLICE& HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: E/16/2016RAM FILES\HRS SYSTEMS\HASS86\OLSEN GUEST QUARTERS(1HD).SDF JOB TITLE: OLSEN GUEST QUARTERS SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 8/16/2016RAM FILES\HRS SYSTEMS\HASS86\OLSEN GUEST QUARTERS(1HD).SDF JOB TITLE: OLSEN GUEST QUARTERS NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 64.0 55.0 500.0 64.0 18.0 37.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 18.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 13.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 0.0 SOURCE 37.0 18.0 2 0.0 - - - - 31.8 - - - 2A 0.0 - - - - 29.8 - - - D 2.0 - - - - 28.2 - - - C 2.0 - - - - 22.2 - - - 2B 0.0 - - - - 22.4 3A 5.0 - - - - 18.2 3B 7.0 HOSE STREAM 16.3 5.0 3 9.0 - - - - 15.3 - - - 4 11.0 - - - - 14.3 - - - 4A 11.0 - - - - 10.3 - - - 5 14.0 - - - - 8.6 - - - 6 15.0 - - - - 7.7 - - - 101 15.0 - - - - 7.7 - - - 102 15.0 - - - - 8.2 - - - 103 14.0 K= 4.90 7.0 13.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/16/2016RAM FILES\HRS SYSTEMS\HASS86\OLSEN GUEST QUARTERS(1HD).SDF JOB TITLE: OLSEN GUEST QUARTERS NFPA2 PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) NotE To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 50.00 150 37.0 1 0.0 37.0 18.0 2A K1.000 T: 6.0 7.00 0.0 2 0.0 31.8 18.0 0.995 G: 1.0 57.00 0.092 5.2 Pipe: 2 0.0 Fixed Pressure Loss Device 2 0.0 31.8 18.0 D 2.0 psi, 18.0 gpm 2A 0.0 29.8 18.0 Pipe: 3 0.0 0.0 3.00 150 29.8 2A 0.0 29.8 18.0 C L1.000 2E: 6.0 6.00 0.9 D 2.0 28.2 18.0 1.025 9.00 0.079 0.7 Pipe: 4 0.0 Fixed Pressure Loss Device D 2.0 28.2 18.0 2B 6.0 psi, 18.0 gpm C 2.0 22.2 18.0 Pipe: 5 0.0 0.0 3.00 150 22.2 C 2.0 22.2 18.0 3A L1.000 2E: 6.0 6.00 -0.9 2B 0.0 22.4 18.0 1.025 9.00 0.079 0.7 Pipe: 6 0.0 0.0 150.00 150 22.4 2B 0.0 22.4 18.0 3B E1.500 2E: 8.6 8.56 2.2 3A 5.0 18.2 18.0 1.500 158.56 0.012 2.0 Pipe: 7 H.S. 5.0 Disch 3.00 150 18.2 3A 5.0 18.2 13.0 3 L1.000 E: 3.0 10.00 0.9 3B 7.0 16.3 18.0 1.025 T: 7.0 13.00 0.079 1.0 Pipe: 8 0.0 0.0 3.00 150 16.3 3B 7.0 16.3 13.0 4 F1.000 E: 2.5 2.50 0.9 3 9.0 15.3 13.0 1.101 5.50 0.031 0.2 Pipe: 9 0.0 0.0 2.00 120 15.3 3 9.0 15.3 13.0 4A A1.000 ---- 0.00 0.9 4 11.0 14.3 13.0 1.049 2.00 0.059 0.1 Pipe: 10 0.0 Fixed Pressure Loss Device 4 11.0 14.3 13.0 5 4.0 psi, 13.0 gpm 4A 11.0 10.3 13.0 Pipe: 11 0.0 0.0 102 6.00 150 10.3 4A 11.0 10.3 13.0 6 F1.000 E: 2.5 8.50 1.3 5 14.0 8.6 13.0 1.101 T: 6.0 14.50 0.031 0.4 Pipe: 12 0.0 0.0 6.00 150 8.6 5 14.0 8.6 13.0 103 F1.000 E: 2.5 8.50 0.4 6 15.0 7.7 13.0 1.101 T: 6.0 14.50 0.031 0.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/16/2016RAN FILES\HRS SYSTEMS\HASS86\OLSEN GUEST QUARTERS(1HD).SDF JOB TITLE: OLSEN GUEST QUARTERS Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 13 0.0 0.0 15.00 150 8.6 5 14.0 8.6 0.0 F1.000 2E: 5.0 5.00 0.4 102 15.0 8.2 0.0 1.101 20.00 0.000 0.0 Pipe: 14 0.0 0.0 1.00 150 7.7 101 15.0 7.7 0.0 F1.000 T: 6.0 6.00 0.0 6 15.0 7.7 0.0 1.101 7.00 0.000 0.0 Pipe: 15 4.90 13.0 Disch 21.00 150 7.7 6 15.0 7.7 0.0 F1.000 6E:15.0 15.00 -0.4 103 14.0 7.0 13.0 1.101 36.00 0.031 1.1 NOTES (HASS) Calculations were performed by the HASS 8.6 computer program in accordance with NFPA13 (2016) under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.005 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 7.4 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.610 4.00 8.00 2.00 9.00 6.00 1.00 10.00 10.00 8.00 Not( TILE COPY Recordall® Disc Meters as Badger Meter Lead-Free Bronze Alloy, Sizes 5/8, 5/8" x 3I4' 3/4" & 1" NSF/ANSI Standards 61 and 372 Certified Model LP-5/8' 5/8" x 3/4" Model 25-5/8 5/8" x 3/4" Model 35—.3/4" '2 y - •.t'. F-. -. Model 55-1" Model 70-1" DESCRIPTION The Recordall Disc Series meters meet or exceed the most recent revision of AWWA Standard C700 and are available in a lead-free bronze alloy. The meters comply with the lead-free provisions of the Safe Drinking Water Act, are certified to NSF/ANSI Standards 61 and 372 (Trade Designations: MI P-LL, M25-LL M35-LL, M55-LL, M70-LL) and carry the NSF-61 mark on the housing. All components of the lead-free bronze alloy meter (housing, measuring element, seals, and soon) comprise the certified system. Applications: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. Operation: Water flows through the meter's strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register. The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register or encoder face. Operating Performance: The Recordall Disc Series meters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates (100 ± 1.5%), and maximum continuous operation flow rates as specifically stated in AWWA Standard C700. Construction; Recordall Disc meter construction, which complies with ANSI/AWWA standard C700, consists of three basic components: meter housing, measuring chamber and permanently sealed register or encoder. The meter is available in a lead-free bronze alloy with externally-threaded spuds. A corrosion-resistant engineered polymer material is used for the measuring chamber. Magnetic Drive: Direct magnetic drive, through the use of high-strength magnets, provides positive, reliable and dependable register coupling for straight-reading or AMR/AMI meter reading options. Maintenance; Badger Meter Recordall Disc Series meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. To simplify maintenance, the register, measuring chamber, and strainer can be replaced without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of parts among like-sized meters and meter models also minimizes spare parts inventory investment. The built-in strainer has an effective straining area of twice the inlet size. Connections: Tailpieces/Unions for installations of meters on various pipe types and sizes, including misaligned pipes, areavailable as an option. Meter Spud and Connection Sizes L ,, ,, Coupling Tailpiece Model Size Designation X Length Bore Dia. Nutand Pipe Thread Spud Thread 5/8" x 7-1/2" 5/8" 3/4(5/8") 1/2" LP 5/8" x 3/4" x 7-1/2' 5/8' 3/4" 1 111 (3/411) 3/4" 5/8' x 7-1/2" 5/8' 3/4(5/8') 1/2" 25 5/8" x 3/4" x 7-1/2" 5/8' 3/4" 1"(3/4") 3/4 3/4" x 7-1/2" 3/4" 1" (3/4") 3/4" 35 3/4" x 9" 3/4". 1(3/4') 3/4" 3/4" x 1" x 91.3/4" 1-1/4(1") 1" 55 1" x 10-3/4" 1" 1-1/4(1") I1" 70 1" x 10-3/4' 1' 1-1/4(1') 1" Tamper-Proof Features: Unauthorized removal of the register or encoder is inhibited by the option of a tamper detection seal wire screw, TORX° tamper-resistant seal screw or the proprietary tamper-resistant keyed seal screw. Each can be installed at the meter site or at the factory. AS 160260 946 BEGONIA CT RDM-DS-00464-EN-03 AWWA (October 2015) FILE copy Product Data Sheet Recordall!Disc Meters, Lead-Free Bronze Alloy, Sizes 5/8 518"x314',' 3/4"& 1" I... , SPECIFICATIONS Model LP Model 25 Model 35 Model 55 Model 70 (5/8" & 5/8" x 3/40) (5/8" & 5/8" x 3/4") (3/4") (1 ") (111) Typical Operating 03 ... 20gpm 0.5 ... 25gpm 0.75 ... 35gpm 1 ... 559pm 1.25 ... 70gpm Range (0.11.. .4.5 m3/hr) (0.11.. .5.7 m3/hr) (100%:t 1.5%) (0.17.. .7.9 m3/hr) (0.23... 12.5 m3/hr) (0.28... 16 m3/hr) 0.25 gpm 0.25 gpm 0.375 gpm 0.5 gpm 0.75 gpm Low Flow (0.057 m3/hr) (0.057 m3/hr) (0.085 m3/hr) (0.11 m3/hr) (0.17 m3/hr) Mm. 95% Mm. 98.5% Mm. 97% Mm. 95% Min. 95% Maximum Continuous 109pm lsgpm 25 gpm 40 gpm' 50 gpm Operation (2.3 m3/hr) (3.4 m3/hr) (5.7 m3/hr) (9.1 m3/hr) (11.3 m3/hr) 5/8" size: 5/8" size: Pressure Loss 2 psi @ 10 gpm 3.5 psi @15 gpm at Maximum (0.14 bar @2.3 m3/hr) (0.24 bar @3.4 m3/hr) 5 psi @25 gpm 3.4 psi @40 gpm 63 psi @50 gpm Continuous 5/8" x 3/4" size: 5/8" x 3/4" size: (0.37 bar @5.7 m3/hr) (0.23 bar @9.1 M3/hr) (0.45 bar @ 113 m3/hr) Operation 1.5 psi @ 10 gpm 2.8 psi @ 15 gpm (0.10 bar @2.3 m3/hr) (0.19 bar @3.4 m3/hr) Maximum Operating 80° F (26°C) Temperature Maximum - Operating 150 psi (10 bar) Pressure Measuring Nutating disc, positive displacement Element Available in NL bronze and engineered polymer to fit spud thread bore diameter sizes: Meter I 5/8" size: I I I Connections 5/8 or I 5/8° (ON 15 mm) I 3/4' (DN 20 mm) I 10 (ON 25 mm) 1" (DN 25 mm) 3/4" (ON 15 mm) I 5/8" x 3/4" size: I 3/4" (DN 15 mm) I MATERIALS Model LP (5/8" & 5/8" x 3/4") Model 25 (5/8" & 5/8" x 3/4") Model 35 (3/4") Model 55 Model 70 Meter Housing Lead-free bronze alloy Housing Bottom Plates Lead-free bronze alloy, cast iron, engineered polymer Cast iron, lead-free bronze alloy T Measuring Chamber Engineered polymer Disc Engineered polymer Trim Stainless steel Strainer Engineered polymer Disc Spindle Engineered polymer Stainless steel Stainless steel Engineered polymer Stainless steel Magnet Ceramic Ceramic Ceramic Polymer bonded Ceramic Magnet Spindle Engineered polymer Stainless steel Stainless steel Engineered polymer Stainless steel Register Lid and Shroud I Engineered polymer, bronze Page 2 RDM-DS-00464-EN703 AWWA October2015 liii Ig,, /9 25 - Recordall' :8* .7 Gallons 3 4' "S 111111 25 #'\ ReordaII" CubIc Feet .3 IioOOO}Q 5 liii, II'' 511111 a A 09 VA -o,oe 0,05 1 11 1101 Product Data Sheet DIMENSIONS Meter Size Model A Laying Length B Height Reg. C Centerline Base Width Approx. Shipping Weight 5/8"and5/8"x3/4"(l5mm) LP 7-1/2(190mm) 3.70(94mm) 1.26"(32 mm) 3.75(95mm) 31b(1.4kg) 5/8(15mm) 25 7-1/2° (190 mm) 4-15/16 (125 mm) 1-11/16(42mm) 4-1/4° (108 mm) 4-1/2 lb (2 kg) 5/8 x 3/4(15mm) 7-1/2 (190 mm) 4-15/16(125mm) 1-11/16(42mm) 4-1/4(108mm) 4-1/2 lb (2 kg) 3/4" (20 mm) 35 7-1/2(190mm) 5-1/4" (133 mm) 1-5/8" (41 mm) 5" (127 mm) 5-1/2 lb (2.5 kg) 3/4° (20 mm) 9" (229 mm) 5-1/4(133 mm) 1-5/8" (41 mm) 5(127mm) 5-3/4 lb (2.6 kg) 3/4" x 1(20 mm) 9(229mm) 5-1/4" 033 mm) 1-5/8" (41 mm) 5(127mm) 6 lb (2.7 kg) 1"(25 mm) 55 10-3/4 (273 mm) 6(152mm) 2-1/32' (52 mm) 6-1/4" (1159 mm) 8-3/4 lb (3.9 kg) 1(25 mm) 70 10-3/4° (273 mm) 6-1/2" (165 mm) 2-5/16 (59 mm) 7-3/4(197 mm) 11-1/2 lb (5.2 kg) i REGISTERS I ENCODERS Standard—Sweep-Hand Registration The standard register is a straight-reading, permanently sealed magnetic drive register. Dirt, moisture, tampering and lens fogging problems are eliminated. The register has a six-odometer wheel totalization display, 360" test circle with center sweep hand, and flow finder to detect leaks. Register gearing is made of self-lubricating engineered polymer, which minimizes friction and provides long life. The multi-position register simplifies meter installation and reading. The register capacity is 10,000,000 gallons (1,000,000 ft', 100,000 m3). A Model 25 register is used in the following example: Model Gallon Cubic Feet Cubic Meter LP 10 1 0.1 25(5/8") 10 1 0.1/0.01 25(5/8" x 3/4) 10 1 0.1/0.01 35 10 1 0.1 55 10 1 0.1 70 10 1 0.1 Optional—Encoders for AMR/AMI Reading Solutions AMR/AMI solutions are available for all Recordall Disc Series meters. All reading options can be removed from the meter without disrupting water service. Badger Meter encoders provide years of reliable, accurate readings for a variety of applications and are also available pre-wired to Badger Meter approved AMR/AMI solutions. See details at www.badgerniefer.com. October 2015 RDM-DS-00464-EN-03 AWWA Page 3 Recordall® Disc Meters, Lead-Free Bronze Alloy, Sizes 518.518"x314','314"& 1" PRESSURE LOSS CHARTS Rate of Flow in Gallons per Minute Model LP 5/8" Model LP 5/8" x 3/4" 1 in inn 25 __ — — ______. — 151 ME — ______. - ______. I — MENIME MENMEMINNIN ______. IMIEW — IMMENIMEN - ------a ______R_ _____.. ___. Model 25 5/8' 1 10 100 4 ç n 4n An qn 25 20 15 U, 0 -J— !vi 0r 1: 0 Page 4 RDM-DS-00464-EN-03 AWWA October2015 Product Data Sheet PRESSURE LOSS CHARTS (CONTINUED) Rate of Flow in Gallons per Minute Model 25 5/8" x 3/4" ____ Is ___. - — ______. - ______. 15 vi 10 — _____.. ________._ — ___--.. ________.. — — Model 353/4" 1 1 0 100 2 4 6 R 70 40 60 Rfl 25 20 15 14 vj 10 0. 5 0 Model 551" - - - _10 100 1' -____ — ___. - no — _ ____. — __. _--_____.. — _____.. — __. - _____.. — _.. _. — _ — ______. — — ______. ______. - -momm mmmm — _____.. __.. ___. October2015 RDM-DS-00464-EN-03 AWWA POge 5 Recordail® Disc Meters, Lead-Free Bronze Alloy, Sizes 518'1'518"x314'1'314"& 1" PRESSURE LOSS CHARTS (CONTINUED) Rate of Flow in Gallons per Minute Model 70 1" 1 10 100 Li 40 60 80 ____ — ______.- ______. — __. — ______. - I — — — — ACCURACY CHARTS Model LP 5/8" .1 1.0 10 Model LP 5/8" x 3/4" .1 1.0 10 100 100 Page 6 RDM-DS-00464-EN-03 AWWA October2015 Product Data Sheet ACCURACY CHARTS (CONTINUED) Model 25 5/8" Model 25 5/8" x 3/4" I I -----...u-----....u------.... —_—___••••—_---.•.•.—_--__.... -----.....-----.....------...I -----.....-----.....-------.mm MOON u. ------.... ------...I------ .... ------....------Ru..-----..... Model 353/4" I I, $ • .1 : MEMO MOON —_---•••••—_—_-.....—_—__..... ., _____...l.______._.______.... I —_—___..lI—_—IMMOMMIN ___....—_—___.... MMMIENEM October2015 RDM-DS-00464-EN-03 AWWA Page? Recordall Disc Meters, Lead-Free Bronze Alloy, Sizes 518','518"x314'1'314"& 1" ACCURACY CHARTS (CONTINUED) Model 551" 1 1.0 10 100 Model 701" 1.1 10 IQ Dti4sP:i. m ME III ~mmmm No ME SIMMONS IN ME low ONSOMENSON MMOM 10 ------....------..u.-----..... • 0- ~mmmmommom on —_—_---..---___....—_—__—.l. V on —_—___••••—_—____...---___.... ___.... I ONE Emmimmimmimm —_—___....—_—__•-...—_--_-...• _____•••._____..... _____.... ______... is— ~mmmomme MEN on Making Water Visible® MAKING WATEE VISIBLE rd FIECORDALI aft regi ;trred iiadernaikc of Badger Meter. Inc. Other trademarks appearing in this document are tile property of their respedive entities. Om to srsflhinus,us r'svarch, pieduct ilnprnven,eni; end enhencemente, Badger Meter reserves the right to change piodurf or system specifications without notics.vvcept to the osMotan outstanding contractual cI.11igation seirlo. 32015 Bsdger , Meter, Inc. All rights reserved. www.badgermeter.com The Americas 10ettyarMeter 1454" 5v,st Bioan I'ae lcd 1 Pc Sox 24501s1 I MIS, uLe, WI 53224-9530 0110-3711-3337 2 414-755-0400 MCuko I Badger Meter de las Rinerkas, S.A. cia C.V. I P-i-dfo Luis Ormed.i 1,4*321 Esq. IrsjelirIa N'24 I Celonia Guadalupe im, CI' S1OSO 1 MOsico, OF I M®ctro 1 +2-55-5662-08t7. Europe, Middle East and Africa I Badger Meter Europa GrnbH I l4url0a, 51r2'0 1 720t9 Np,jhlen +'i9-7025-ccflS.0 Europe. Middle East Branch Office I IladgerMete, Europe I '0 9oe341432 1 OciLcal Silken Oasis, -Isad bader tiiMiio. Wig C Oliire K20 I Oat'ec / LISt I .S714.t? 12503 Czech Republic I Badger Meter Czech Republic s.r.o. I Matikaa 2062i"--51621 113 0re, Czech Icapubli: 1 +42,'-S-414 X41 1 Slovakia I Badger Meter Slovakia are. I fsirissmk,, 1119/I3 i 531 '12 9tisIav, Slc',ak,v I f421-2-44 1539331 Aria Pacific I Badger Meter 180 Marine Paicir FIst 21-05 F'arkwas facade 1 ITh1gar'ir34492ó0 I -1 65-63464Z36 China I Badger Meter 17-1202 95 lload.1 MirInq Dit,icF I Shanghai I Chits 20-11011 5412 Legacy f3ocurnen,t Numbers: liDM-D5-00002, 63,0I05,tlG. and 73 Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi National Fire Products, LLC RESI-RISERTM The RESI-RISERTM is a pre-assembled, compact, attractive fire sprinkler riser unit for residential sprinkler systems in accordance with NFPA 13, 13R and 13D. The RESI-RISERTM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESI-RISERTM to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet. Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPDT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESI-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESI-RISERTM fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 1%", 1W', and 2" Style: Thread x Thread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent # 6,076,545 RESI-RISERTM Size Chart ________ Description 1" 11/4" 11/2,' 2" Height* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2" Depth 3-1/2" 3-1/2" 3-1/2" 3-1/2" Drain Size 1/2" 1" 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve 0 National Fire Products, LLC (800) 528-7978 Pressure Loss Tables Pressure.Loss in 1" Resi-Riser 12 Pressure Relief/Test and Drain How it Works Normal Position - static Pressure 0 10 15 20 25 30 35 40 Flow (gpm) Pressure Loss in 1-1/4" Resi-Riser Relieving Pressure Exceeding 175 psi MM pip, mad M1111111011 M ILM MM 0 10 15 20 25 30 35 40 45 50 55 60 Flow (gpm) Pressure Loss in 1-1/2" Resi-Riser 10 Lo Manual Open - Drain r Flow Switch Test 0 0 10 15 2025 30 35 40 45 5055 6065 7075 80 Flow (gpm) Pressure Loss in 2" Resi-Riser Locked Closed for Hydrostatic Test 6 0 15 25 35 45 55 65 75 85 95 Flow (gpm) © National Fire Products, LLC (800) 528-7978 7 Of SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 3.0, SIN: SS8361 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 130; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 3.0 (43.2 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (128mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWVVA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARWINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No.U039562 Date : Nov/18/2014 TECHNICAL DATA Approvals: 0UL05 Listed, NSF.61-G Sprinkler Identification Number (SIN): SS8361 Maximum Working Pressure: 175psi (12.1 bar) Discharge Coefficient (Nominal K-Factor): K=3.0 GPM/psi112 (43.2 LPM/bar112) Temperature Rating: 1621 (72°C) Sprinkler with 1401 (60°C) Cover Plate 1751 (79°C) Sprinkler with 1621 (72°C) Cover Plate Color Code (Sprinkler) 1621 (720C): Uncolored 1751 (790C): White Color Code (Cover Plate)• 1401 (6090): No Mark 1621 (72°C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 Page :2of8 2- f 6 ( 52mm) Marking /1-Lot No. I Year of Manufacture I-SIN: SS8361 L-K-foctor : <3.0 I-Temperature Rating 162T/72C E L. Mgjj or I75F/79C I- LContrgl No. 6P37 LNSF Mark NSF-61 -G LRES SPKR 0 Body (Copper Alloy) 0 Deflector (Phosphorus Bronze) IZL- 1A .< 0 Casket (PilE) I ® Fusible Metal (Solder) 2-"(68mm) I (5) Heat Collector (Copper) L square (068mm) Cover Plate Assembly or 2- % or 3-Y4" (83mm) FIGURE 1. Model RC-RES K3.0 Color Code Marking (Deflector) SIN: 558361 IC—teats,: 03.0 Temperature Rating: 167F/72c or UL Mork: COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) OPERATION In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) Normal Condition Cover Plate Operation . Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) Document No. U039562 Date Nov/18/2014 DESIGN CRITERIA Page . 3 of 8 The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority ha ving jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, 6828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of. the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of. temperature rating and maximum allowable coverage area. Document No.U039562 Date Nov/18/2014 Page :4of8 A minimum discharge 0. 1 GPM/sq.ft. [4.07(L/min)/ sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8361 Maximum Ordinary Ordinary Coverage Maximum Temperature Rating' Temperature Rating ' Deflector Minimum Area Spacing 162"F (72°C) 175"F (79°C) to Installation Spacing Ft x Ft Ft. Type Ft. Flow(b)Pressure Flow Pressure(b)Ceiling (m xm) (m) GPM PSI GPM PSI (m) (Umin) (bar) (L/min) (bar) Smooth Ceilings 3/8 to 7/8 12x12 12 9 9.0 9 9.0 Inches. (3.747) (3.7) (34.0) (0.62) (34.0) (0.62) Beamed Ceilings per NFPA 13D,13R Concealed 8 (2.4) or 13 Installed in beam 1014 14 11 13.4 12 16.0 3/8to7/8 (4.3x4.3) (4.3) , (41.6) (0.92) (45.4) (1.10) inches below bottom of beam. For coverage area dimensions less than the' above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. (C) For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Document No. U039562 Date . Nov/18/2014 Page :5of8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.ONm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installing Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No.U039562 Date Nov/18/2014 Page . 6 of Sprinkler Head maim Protective: RemoverCap R Step E4. Hook by turning Step 3 4 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL INCORRECT ICORRECTI I INCORRECTI FIGURE 7. INSTALLATION (CORRECT OR INCORREC1J Document No. U039562 Date Nov/18/2014 Page 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F/4 ' to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100'F /38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No.U039562 Date . Nov/18/2014 Page 8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: S58361, Residential Flat Concealed Sprinkler, Pendent, 1(3.0, Temperature: 162F (72°C) or 175F (7991C)) Cover Plate Assembly: 2-5(8 inch (45 or 3-1/4 inch (83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8" Round, 140°F 0 0 - - - 0 - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - 0 0 3-1/4" Round, 162°F 0 - - - - - - 0 0 Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench & Socket for Model RC-RES Cap Remover RC Document No.U039562 Date Nov/18/2014 I of SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler. Pendent. II = Model: RC-RES, K-Factor: 4.9. SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential. Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 131); wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWAs Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. The Mode! RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U085160 Date Feb/09/2015 TECHNICAL DATA Page 2 of 8 Approvals: cULus Listed, NSF-61-G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1 bar) Discharge Coefficient (Nominal K-Factor): K4.9 GPM/psi112 (70.6 LPM/bar112) Temperature Rating: 1621 (72°C) Sprinkler with 1401 (60°C) Cover Plate 1751 (79°C) Sprinkler with 1621 (72°C) Cover Plate Color Code (Sprinkler) 1621 (720C): Uncolored 1751 (799C): White Color Code (Cover Plate) 1401 (609C): No Mark 1621 (720C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 OPERATION 2—J6" (052mm) NPT1/2 Marking / Lot No. of Manufacture SIN : S58464 —K—factor : 1(4.9 Temperature Rating 162T/72C E qJ UI Mark or 175F/79C N Control No. : 6P37 NSF Mork : NSF-61 —G RES SPKR (D Body (Copper Alloy) t2) Deflector (Phosphorus Bronze) (2 Gasket (PTFE) ® Fusible Metal (Solder) (2) Heat Collector (Copper) 2— %" (çô 68mm) ID Cover Plate Assembly or 3-Y4" (83mm) or 2— %"square (068mm) FIGURE 1. Model RC-RES K=4.9 de Color SIN 5S8464 r co r k—factor: K4.9 Temperature Rating I 62r/72c or I7SF/79C UL Murk CCD COVER PLATE SPRINKLER (lop view) (Bottom view) FIGURE 1-1. Marking (Color Code) In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) o 1 I1ViciIiiMUiMI 'I1MM Normal Condition Cover Plate Operation mio Sprinkler Operation =# Water Discharge FIGURE 2. OPERATION PROCESS tThe figure is for illustrative purpose only) Document No. U085160 Date Feb10 9/2015 DESIGN CRITERIA Page :3of8 The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority ha ving jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 130 or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM 8813, B828, and CDA (Copper Development Association), - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Document No. U085160 Date . Feb/09/2015 Page :4of8 A minimum discharge 0.1GPM/sq.ft. [4.07LPM/sq.m] over the 'design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLEA. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Mode! SS8464 Maximum Ordinary Intermediate Cover ag e Maximum Temperature Rating Temperature Rating Deflector Minimum Area° Spacing 162"F (72°C) 175"F (79°C) to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ft. Ceiling Type Ft. (mxm) (m) GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) Smooth 12x12 12 13 7.0 13 7.0 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) 3/8 to 7/8 Inches. 1014 14 13 7.0 13 7.0 (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings per NFPA 16x16 16 13 7.0 14 8.2 13D,13R Concealed 8 (4.90.9) (4.9) (49.2) (0.48) (53.0) (0.57) or 13 (2.4) Installed in beam 18X18 18 17 12.0 18 13.5 3/8 to (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) 7/8 inches 20x20 20 21 18.4 - below (6.1x6.1) (6.1) (79.5) (1.27) bottom of beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Document No. U085160 Date Feb/09/2015 Page :5 of 8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.ONm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from thó sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installinc, Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler. Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Ave. J (6.4mm) Do NOT t Groove on the Sprinkler Over-lightenMm. .t(3.2mm) Tolerance Limit Make a Space Here C&Ing Protective COD IC e of _ C&Iing Surface Ceilin Level Mountin Mountin Surface aroove of the Socket Wrench 2-/,(46Omn Ceiling Nole Diameter Socket CORRECTJ I FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No.U085160 Date Feb/09/2015 b or Step Hook by turning Step 3 4 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL Cu LI Ji LL El Ia fll=S I 01 CeiIing Ceiling,I s a—a ng = I Mounting Surface E Deflector 'p Cover Plate AsserribI %" L8mm2— ( or 3- Y4" (0 83mm) or 2- Wsquare (068mm) FIGURE 6 Document No.U085160 Date Feb/09/2015 Page :70f8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F/4 ' to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100'F /38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No.U085160 Date . Feb/09/2015 Page.8of8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C)) Cover Plate Assembly: 2-5/8 inch (068mm) or 3-1/4 inch (083mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes Mite Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8" Round, 140°F 0 0 - - - 0 - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - 0 0 3-1/4" Round, 162°F 0 - - - - - - 0 0 Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench & Socket for Model RC-RES Cap Remover RC Document No. U085160 Date Feb/09/2015 Fl Res 30, 49, 58 & 76 Recessed Pendent / Fl Fl Res 30, 49, 58 & 76 Recessed Pendent/ FP Fl Res 30, 49, 58 & 76 Fl Res 44&58 CCP Pendent Recessed HSW/F2 Fl Res 44SWC Bulletin 135 Rev. M Rielabk 0 Model Fl CD Residential Sprinklers for Design Density of .05 gpm4t2 Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpmflt Types: Fl Res 30Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/F1 Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/F1 Fl Res 58 Recessed Pendent/FP Fl Res 76 Pendent Fl Res 76 Recessed Pendent/Fl Fl Res 76 Recessed Pendent/FP Fl Res 30 CCP Pendent Fl Res 49 CCP Pendent Fl Res 58 CCP Pendent Fl Res 76 CCP Pendent Fl Res 44HSW Fl Res 44 Recessed HSW/F2 Fl Res 58HSW Fl Res 58 HSWX KRes58 HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: ½" NPT (R1/2) K-Factor: 3.0 (43.2) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (83,5) (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent Sprinkler 4.4(63) (Actual) - Fl Res 44 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model Fl Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 130, 13R, or 132013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*, Fl or F2. Data: the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model 0 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" mark- ing must face ceiling. Type Adjustment Inch (mm) "A" Inch (mm) Face of fitting to ceiling Inch (mm) Deflector Distance below bottom of beam Inch (mm) Fl 319.0) Mm. Recessed = 1/a (41.3) 3/s(9.5) 13/4(44.4) Max. Recessed =/s (22.2) 11/8(28.6) 1(25.4) 1/2 (12.7) Mm. Recessed = 1/s (41.3) 3/ (9.5) 13/4(44.4) Max. Recessed V/a (28.6) 7/s(22.2) 11/4 (31.7) * Note: Escutcheons Fl or F2 may be used with Model Fl Res 49, 58 & 76 Recessed Pendent Sprinkler Model Fl Res 30 Recessed Pendent / F2 . Model Fl Res 30, 49, 58 & 76 Pende nt • Mod l I-i lies 4. bS & lb liecessea ieni lent/Fl El escutcheon, !4 (19mm) adjustment 1/4 HOLE [57.[57.2-1 _44 I I5/I6 014. [492m 3 12 X 1;2 REDUCER TURN COLLAR UNTIL lIGHT AGAINST SPRINKLER FACE OP FITI7NC To WRENCH BOSS. CEILING DIMENSION, I/8 (Fl ESCUTCHEON) 3/r-7/8" (P2 ESCUTCHEON) ADJUSTMENT I A A A t m3 2 27/332 ON 2mmj_ . Fig. 1 Fig. 2 Technical Data: F1 Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size I Nominal Orifice I Inch (mm) Max. Pressure psi (bar) I Sprinkler Temp. Rating I Max. Ambient Temp. I Actual K Factor I Sprinkler Length I Inch (mm) I I OF °C I ½'NPT (R½) I I 21/' (8 2) 175 (12) I 155 I 175 I 79 I 68 I 100 38 3.0(43.2) 2.25 (57) Max. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Spacing (155°FI8°C) (1750F1790C) Top of Deflector to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) PSI (bar) GPM (1/mm) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0 (0,48) 8(30,3) 7.0(0,48) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. BeamedCeilingsperNFPA13D, 13R 8(2,4) 14x 14(4,3x4,3) 11(0,76) 10(37,8) 11(0,76) 14(4,3)E10(378) x 16 (4,9 x 4,9) 16(4,9)13 (49) 18.8(1,3) or 13 installed in beams 1¼ to 1.416 13(49) 18.8(1,3) (31.7 to 44.4) using F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 2. Technical Data: F1 Res 49 Pendent and Recessed Pendent (SIN R3516) Thread I Nominal Orifice Max. I Sprinkler I Max. I Actual I Sprinkler Size Inch (mm) I Pressure Temp. Rating I Ambient Temp. I K I Length OFOC I OF IOC psi (bar) Factor I Inch (mm) ½" NPT j 1/2) I 175(12) I 155 I I I 68 I 100 38 I 150 I 66 I 4.9 (70.6) 2.25(57) (R 175 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°F,8°C) (175°Fi790C) to Ceiling Spacing Flow Pressure Flow Pressure Ftx Ft(m x m) Ft (m) GPM(L/min) PSI (bar) GPM(Llmin) PSI (bar) Inch (mm) Ft(m) 12 x 12 (3,6 x 3,6) 12(3,6) 13(49) 7.0 (0,48) 13 (49) 7.0(0,48) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) 13(49) 7.0(0,48) 1 t 4(25.4 to 102) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) 13 (49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8 (2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12 (0,83) 17(64,3) 12 (0,83) beams 1¼ to 1A (31.7 to 44.4) using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7 (1,14) 20(75,7) ;~~Iescutcheon to 1.4 (25.4 to 44.4) using Fl For Ceiling types refer to NFPA 13, 13R or 13D Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (1550F8°C) (175°F/79°C) Ft x Ft (mx m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure GPM (1/mm) PSI (bar) GPM (LIiiin) PSI (bar) Inch (mm) Ft (m) 12x 12(3,6x3,6) 12(3,6) 15(57) 9.4(0,65) 15(57) 9.4(0,65) Smooth Ceilings 4to8(looto 203) using F2 escutcheon. 14x 14(4,3x4,3) 14(4,3) 16(60,5) 10.6(0,73) 16(60,5) 10.6(0,73) 4t08(100t0203) using Fl escutcheon. 16 X 16(4,9 X 4,9) 16(4,9) 17(64,3) 12.0(0,83) 17(64,3) 12.0(0,83) Beamed Ceilings per NFPA 131), 3R or 13 installed in beams 8(2,4) 18x 18(5,5x5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 4¼t08(108t0203) using F2 escutcheon, 4 to 8(100 to 203) 20 x 20(6,1 X 6,1) 20(6,1) 22(83,2) 20.2(1,4) 22(83,2) 20.2(1,4) using Fl escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread I Nominal Orifice Max. I Sprinkler Max. I Actual Sprinkler Size Inch (mm) Pressure I Temp. Rating i Ambient Temp, K Factor I Length OF I °C OF °C psi (bar) I I Inch (mm) Y2" NPT (R½) I ½"(13) 175 (12) I 155 I 175 68 I 79 100 150 I 38 I 66 I 5.8 (83.5) I 2.25 (57) Max. Coverage area Max. Spacing Ordinary Temp. Rating (l55°Fi8°C) Intermediate Temp. Rating (175°F,Th°C) Top of Deflector Minimum Ft x Ft (mx m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure GPM (Lnin) PSI (bar) GPM (Llmin) PSI (bar) Inch (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3.6) 16(61) 7.6 (0,53) 16(61) 7.6 (0,53) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) 16(61) 7.6(0,53) 1 t 4(25.4 to 102) using Fl escutcheon. 16x 16(4,9x4,9) 16(49) 16(61) 7.6 (0,53) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 13D, 3R or 13 installed in beams 8(2,4) 18x 18(5,5x5,5) 18(5,5) 19(72) 10.8(0,75) 19(72) 10.8(0,75) 114to134 (31.7t044.4)using F2 escutcheon, 1 t 13 (25.4 to 20x20(6,1 X6,i) 20(6,1) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 3, Technical Data: Fl Res 76 Pendent and Recessed Pendent (SIN R7618) Thread I Nominal Orifice I Max. I Sprinkler I Max. I K I Sprinkler Size I Inch (mm) Pressure J Temp. Rating I Ambient Temp. I Factor Length I OF I OC OF °C I I psi (bar) Inch (mm) I 'Is" NPT I (R/) a /32" (13.5) 175 (12) 155 175 I 68 79 100 I 150 I 38 I .66 7.6(109) 2.25(57) Ordinary Temp. Rating Intermediate Temp. Rating . Minimum Max. Coverage area Max. Spacing (155°Fi8°C) (175°F/79°C) Top of Deflector to Ceiling Spacing Row Pressure Flow GPM Pressure Ft x Ft (mx m) Ft (m) Inch (mm) PSI (bar) (1/mm) PSI (bar) 12x 12(3,6x3,6) 12(3,6) 21(79,5) 7.6(0,53) 21(79,5) 7.6(0,53) Smooth Ceilings 4¼to8(108 o 203) using F2 escutcheon. 14x 14(4,3x4,3) 14(4,3) 21(79,5) 7.6(0,53) 21(79,5) 7.6(0,53) 4t08(100t0203) using Fl escutcheon, 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6(0,53) 21(79,5) 7.6(0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18x 18(5,5x5,5) 18(5,5) 21(79,5) 7.6(0,53) 21(79,5) 7,6(0,53) beams 41Ato8(108t0203)us- ing F2 escutcheon, 4 to 8(100 20x20(6,1 x6,1) 20(6,1) 23(87,1) 9.2(0,63) 23(87,1) 9.2(0,63) t0203) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 30, 49, 58 & 76 CCP Pendent* * Not listed for corrosion resistance. 2 5/8" (66.7mm) 0/A. 2 5/16" 0/A. HOLE IN CEILING [58.7mm] CUP 1"x112" REDUCER CUP CEILING .. -'- I ; J l;" ! MAX. FACE OF F7TTING TO FACE OF CEILING DIMENSION COVER ADJUSTMENT HEIGHT 3 5/16" 0/A. 135FG04E (84.7mm) - Fl RES 30, 49, 58 & 76 CCP PEND. Fig.3 Note: The Fl Res 76 will use a 1" x "reducer. CCP Cover Plate Data: Cover Adjustment "B" CCP Height oc,, Deflector Distance below bottom Inch (mm) Inch (mm) of beam Inch (mm) 1/2(12.7) 11/16 (24) ½ (13) - 1(25,4) /s6 (7.9) /4(19) 1 1/2(13) - 1(25.4) Model Fl Res 30, 49, 58 & 76 FP push-on/thread-off escutcheon 2 5/8" 0/A. [66.7mm] —HOLE IN CEILING- 2 5/16" 0/A. - (58.7mrnJ CUP - 1" X 1/2" REDUCER 1 I/2"[38.lmm] MAX. FACE OF FITTING LIK TO FACE OF CEILING 3ION 1/2" [13mm]1 FP ADJUSTMENT Fl RES 49 PENDENT/FP Fig. 4 FP Escutcheon Data: FP Position "A" Deflector Distance below bottom Inch (mm) of beam Inch (mm) Max. Recessed /18(11) 1/2 (12.7) Mm. Recessed '/I6(24) 1(25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above, 4' Technical Data: F1 Res 30 CCP Pendent and Recessed PendentlFP (SIN R3511) Nominal Max. CCP Assembly I Max. K I Sprinkler Thread Size Orifice I Pressure I Temp. Rating Ambient Temp, I Factor Length OF °C I OF I Inch (mm) psi (bar) I Inch (mm 21/ (8.2) 175(12) 135 ½" NPT ) 57 100 J 38 3,0(43.2) 2.25(57) (R½) Ordinary Temp. Rating Minimum Max. Coverage area Max. Spacing (155°Fi8°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) PSI (bar) Smooth Ceilings ½ to 1(13 to 25.4) using COP. 12 X 12(3,6 X 3,6) 12(3,6) 8(30,3) 7.0(0,48) ½ to 1(13 to 25.4) using FP escutcheon. Beamed Ceilings per NFPA 131), 13R or 13 installed in 8(2,4) 14x 14(4,3x4,3) 14(4,3) 11(37,8) 13.4 (0,92) _________ beams ½ to 1(13 to 25.4) using OCR ½ to 1(13 to 25.4) using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: Fl Res 49 CCP Pendent and Recessed Pendent./FP (SIN 3516) Nominal Max. CCPMax. Assembly Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size Inch psi (bar) Rating Temp. Factor Inch (mm) (mm) OF 1°C OF OC ½" NPT (R½) /i&' (11) 175(12) 135 57 I 100 I 38 1 4.9 (70.6) 2.25(57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155°FI8°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) PSI (bar) 12x 12(3,6x3,6) 12(3,6) 13(49) 7.0(0,48) Smooth Ceilings ½ to 1(13 to 25.4) using 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) COP. ½ to 1(13 to 25.4) using FP escutcheon. 16x 16(4,9x4,9) 16(4,9) 14(53) 8.2(0,56) Beamed Ceilings per NFPA 13D, 13Ror13 installed in beams ½ to 1(13 to 25.4) using 8(2,4) 18x 18(5,5x5,5) 18(5,5) 18(68,1) 13.5 (0,93) CCP. ½ to 1(13 to 25.4) using F escutcheon. 20 x 20 (6,1 x 6, 1) 20(6,1) 20(75,7) 16.7(1,14) For Ceilina tvoes refer to NFPA 13. 13R or 13D Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Nominal I Max. CCP Assembly I Max. K I Sprinkler Thread Orifice Pressure I Temp. Rating I Ambient Temp. 1 Length Size Inch (mm) psi (bar) Factor I I Inch (mm) I OF I °C Y2" NPT (R½)1/2"(13) 175(12) 135 57 It OO F t38 C 5.8(83.5) 2.25(57) Max. Coverage Ordinary Temp. Rating . Minimum area Max. Spacing (1550 80C) . Top of Deflector to Ceiling Spacing Flow Pressure Ft Ft (m) Inch (mm) . Ft (m) 11mm) PSI (bar) 12x 12(3,6x3,6) 12(3,6) 16(61) 7.6 (0,53) Smooth Ceilings ½ to 1(13 to 25.4) using COP. 1/2 to 1(13 to 25.4) using FP escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6 (0,53) 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2 to 1(13 to 25.4) using COP. 8(2,4) 18 x 18 (5,5 x 5,5) 18 (5,5) 19(72) 10,8 (0,75) ½ to 1(13 to 25.4) using FP escutcheon. 20x20(6,1x6,1) 20(6,1) 22(83,3) 14.4 (1,0) For Ceiling types refer to NFPA 13, 13R or 13D 5. I 15/76" DIA.t, (49.2mm] I '- TURN COLLAR UNTIL -" TIGHT AGAINST SPRINKLER WRENCH BOSS. 135F606-0 Fl RES 58 & Fig Technical Data: Fl Res 44 IH Nominal Max. Thread Orifice Pressu Size Inch (mm) psi (ba ½" NPT /8" (10) 175 (12 Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Nominal Max. I CCP Assembly I Max. I K Sprinkler Orifice I Pressure I Temp. Rating I Ambient Temp. Factor Length J I °C I °F EThmead Inch (mm) I psi (bar) I °CInch (mm) I 7/0 (13.5) 175(12) 135 I 100 150 I 38 I 66 . 7.6(109) 2.25(57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155- 8,C) Top of Deflector to Ceiling spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 21(79,5) 7.6(0,53) Smooth Ceilings ½ to 1(13 to 25.4) using CCP. V2 to 1(13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4.3) 21(79,5) 7.6 (0,53) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6(0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams ½ to 1(13 to 25.4) using CCR 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 22(83,3) 8.4 (0,58) ½ to 1(13 to 25.4) using FP escutcheon. 20x20(6,1 x6,1) J 20(6,1) 25(94,6) 10.8 (0,74) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 44 & 58 HSW FACE OF FITI3NG TO I WALL DIMENSION '1TIIFr I 1/4" MIN. " DIMENSION 2 1/4" HOLE 0/A. [31.8mm] "A CEILING To (5 7.2mm] (3.2mm] DEFLECTOR I' X 7/2" REDUCER -p S R,.,1I 04 fl AA 0 O UtA4Ifl I Max. Coverage area Ft x Ft (mx m) Max. Spacing Ft (m) Ordinary Temp. Rating (155-- 80C) Intermediate Temp. Rating (1750Fi79°C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Llmin) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12x 12(3,6x3,6) 12(36) 12(454) 75(0,52) 12(45,4) 7.5(0,52) 4t06(100to 152); Y2(13)recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 14(53,0) 10.2(0,71) 14 (53,0) 10.2(0,71) 16x 16(4,9x4,9) 16(4,9) 16(60,6) 13.3 (0,92). 16(60,6) 13.3(0,92) 16 x 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8 (1,16) 18(681) 16.8(1,16) 18x 18(5,5x5,5) 18(5,5) 19(72,0) 18.7(1,29) 19(72,0) 18.7(1,29) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4 (1,89) 23(87,1) 27.4(l.89) 12x 12(3,6x3,6) 12(3,6) 14(53,0) 10.2(0,71) 14(53,0) 10.2(0,71) 6t0 12 (152 to 305); ½(13) recessed using F2 escutcheon 14 x 14(4,3 x 4,3) 14(4,3) 16(60,6) 13.3(0,92) 16(60,6) 13.3 (0,92) 16 x.16 (4,9 x 4,9) 16(4,9) 17(64,4) 15.0(1,04) 17(64,4) 15.0 (1,04) 16x 18(4,9x5,5) 16(49) 20(75,7) 20.7(1,43) 20(757) 20.7(1,43) 16 x 20 (4,9 x 6, 1) 16(4,9) 23(87,1) 27.4(1,89) .23(87,1) 27,4(1,89) For Ceiling types refer to NFPA 13, 13R or 13D Nominal Max. Sprinkler Max. Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Size Inch psi (bar) Temp. _________ Factor Inch °F I °C ______ (mm) (mm) 1/2" NPT 1/"(3) 175 (12) f15 I 38 ff 100 5.8(83.5) 2.45(62) 150 66 Escutcheon, F2, Data: Adjustment Face of Fitting Type Inch (mm) to wall Inch (mm) F2 1/2(13) (4.7-17.4) Ordinary Temp. Rating Intermediate Temp. Rating Max. Coverage area Max. Spacing (155°F80C) (175°FII9°c) Top of Deflector to Minimum Ft x Ft (m x m) Ft (m) Flow Pressure Flow Pressure Ceiling Spacing ... ,...... Inch (mm) Ft (m) uuIIuI, I-I 1IVl IIuuuuI; UI 12 x 12(3,6 x 3,6) 12(3.6) 16(60,6) 7,6(0,53) 16(60,6) 7.6 (0,53) 14 x 14 (4,3 x 4,3) 14(4,3) 18(68,2) 9.7(0,69) 18(68,2) 9.7 (0,69) 16x 16(4,9x4,9) 16(4,9) 21(79,5) 13.2(0,91) 21(79,5) 13.2(0,91) V2(13)recessed 4 to 6 ( 100 to 152); 16x 18(4,9x5,5) 16(4,9) 25(94,7) 18.6(1,28) 25(94,7) 18.6(1,28) using F2 escutcheon 16 x 20(4,9 x 6,1) 16(4,9) 29(109,8) 25.0(1,73) 29 (109,8) 25.0(1,73) 12x 12(3,6x3,6) 12(3,6) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 14 x 14(4,3 x 4,3) 14(4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 6 to 12 (152 to 305); V2(13)recessed 16 x 16 (4,9 x 4,9) 16(4.9) 26 (98,4) 20.1(1,39) 26 (98,4) 20.1 (1,39) using F2 escutcheon 16x 18(4,9x5,5) 16(4,9) 31(117,4) 1 28.6(1,97) 1 31(117,4) 1 28.6(1,97) Ceiling types refer to NFPA 13, 13R or 13D 8(2,4) ri Model Fl Res 44 SWC * Not listed for corrosion resistance. r".t 4 to 72 I I/4 (37.75mm) Moefroom (101.60mm ) To 304.80mm Poce Of P.16ng To Woo On'oonn,no PUSH ON COVER. EN fl/RN TO ADJUST UNIIL FIGHT AGAINST WALL. S I/2 Reducer Recommended (n?) V 115- 1 t COL flGHT AGAINST SPRINKLER WRENC14 BOSS. 21132* r14 Adjustment Fl RES 44 SWC Fig. 6 Taihnii flzt F1 RPQ Ad SW( (IFqI P2q1 Nominal Max. Cover Max. Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size Inch (mm) psi (bar) Rating P. Factor Inch (mm) OF I OC OF IOC WNPT I (R 1/) 3/8" (10) 175(12) 135 I 57 100 I 38 4.4(63) 2.45(62) Ordinary Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (1550 80C) Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Llmin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3.6) 13(49,2) 8.7 (0,60) 4 to 6(100 to 152); 14 x 14(4,3 x 4,3) 14(4,3) 14 (53.0) 10.2(0,71) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 15.0(1,1) ½ (13) recessed using F2 escutcheon 16x 18(4,9x5,5) 16(4,9) 19(71,8) 18.7(1,13) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 23 (87,1) 27.4(l.89) 12 x 12(3,6 x 3,6) 12(3,6) 14(52,9) 10.2(0,71) 6t0 12(152t0305); ½ (13) recessed 14x 14(4,3x4,3) 14(4,3) 15(56,7) 11.7(0,81) 16x 16(4,9x4,9) 16(4,9) 18 (68,1) 16.8(1,16) using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 20(75,6) 20.7(1,43) For Ceiling types refer to NFPA 13, 13R or 13D 91 Technical Data: Fl Res 58 HSWX (SIN RA3533) Thread Nominal Max. Sprinkler Max. Ambient I I K Sprinkler Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) OFIOCI Number (SIN) °F I°C Bulb _______ WNPT 1/2 (13) 175 (12) 155----p38 1759 100 150 I 38 I 66 5.8 (83.5) 2.45(62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°Fi80C) Intermediate Temp. Rating (175°F/79°C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (1/mm) Pressure PSI (bar) Flow GPM (Llmin) Pressure PSI (bar) 18 x 20(5,5 x 6,1) 18(5,5) 30(114) 26.8(1,85) 30 (114) 26.8(1,85) 4t06(100to 152); ½ (13) recessed using F2 escutcheon 8(2.4) 20x20(6,1 x6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 16 x 22(4,9 x 6,7) 16(4,9) 33(125) 32.4(2.23) 33(125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9 (2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4 (3,75) 42(160) 52.4 (3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35 (133) 36.4 (2,5) 35 (133) 36.4(2,5) 6 to 12 (152 to 305); ½(13) recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) 42(160) 52.4(3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) F62.9 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 58 HSWX (RuIh FACE OF FITTING TO WALL DIMENSION 11116- MW. [31.8mm) I I I 2 1/4" HOLE 014 . ':4" " (5 7.2mm) CEILING TO I 3.2mm) DEFLECTOR I 1" X 1/2" REDUCER -'---p DIMENSION j:i .DIAj i TURN COLLAR UNOL lIGHT AGAINST SPRINKLER WRENCH BOSS. —.'.-] 1/2" [13mm) ADJUSTMENT Fl RES 58 HSWX '7 Model KRes58 HSWX (Link 04 Technical Data: KRes58 HSWX (RA3593) Thread Nominal Max. Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) Number (SIN) °F I Link ½" NP I lb"(13) 175(12) 100 38 5.8 (83.5) 2.45 (62) RA3593 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165- 40c) of Deflector to Top ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (tfmin) Pressure PSI (bar) 18x20(5,5x6,1) 18(5,5) 29(109) 25(1,72) 4 to 6(100 to 152); ½ (13) recessed using F2 escutcheon 8(2,4) 20 x 20 (6,1 x 6, 1) 20(6,1) 30(114) 26.8(1,85) 16 x 22 (4,9 x 7,3) 16(4,9) 33(125) 32.4(2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 14 x 26 (4,3 x 7,9) 14(4.3) 42(160) 52.4 (3,75) 18 x 20(5,5 x 6,1) 18(5.5) 35 (133) 36.4(2,5) 6 to 12 (152 to 305); ½ (13) Recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42 (160) 52.4(3,6) 14 x 26 (4,3 x 7,9) 14(4.3) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 130 Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and Fl Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (791C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model Fl Res 30,49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30, 49 & 58 Recessed Pendent/ F2, Model Fl Res 30,49 & 58 Recessed Pendent/ FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be 1" to 8" maximum, only for FiRes 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded *DuPont Registered Trademark 10. or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with 3/4" adjustment (Model F1)][of push-on and thread off design with 1/2" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model Fl Res 30, 49 & 58 Recessed Pendent/Fi] [Model Fl Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30, 49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturers installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of. attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1/2" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify], ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard, Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- DuPont Registered Trademark 11. leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model 172) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify], Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with 'recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard'finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Reliable is Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 06/15 P/N 9999970235 Model Fl Res 76 Recessed Pendent/Fl, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturers technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturers installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjust- ment (Model F2)] [with 3%" adjustment (Model Fl)] [of push-on and thread off design with 1/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model Fl Res 76 Recessed Pendent/F2] [Model El Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate" tem- perature rating shall be135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1,F2,FP Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black White Painted Polyester(l) Coated Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electroless Nickel PTFE(Teflon®)(2) Electroless Nickel PTFE (Tef lone) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull Chrome Dull > Other finishes and colors are available an special order. Consult factory for details. (2) cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler MOdel Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish "DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. . k. 4 .... Recessed Conceale Horizontal Sidewall Pendent Recessed Pendent/FP Bulletin 014 Rev. N Reliable® Model Fl FR Series Quick Response Glass Bulb Sprinklers w 3 0 —s Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kIer Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed PendentiF1/F2 XLH Upright XLH Pendent Pendent F1/F2 "1> Underwriters Laboratories Inc. and Certified for Product Description Canada (cULus). Reliable Model F1FR series sprinklers FM Approvals (FM) are quick-response automatic sprin- Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element. VdS Schadenverhutung GmbH (VdS) Model F1 FR series sprinklers are Stan- ! NII ('rtfir1 tn M/LMi tnrrr1 Al innv r dard Spray sprinklers, with the excep- (NSF) tion of the Model Fl FR56 COnventional XLH Recessed 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) The Model F1 FR Series automatic sprinklers utilize, a 3.0 (EC) mm frangible glass bulb. These sprinklers have demonstrat- UL Listing Category ed response times in laboratory tests which are five to ten Sprinklers, Automatic & Open (VNlV) times faster than standard response sprinklers. This quick Quick Response Sprinkler rnL nnoin cnhILc, fh I1Q Q,ric, o r,Irc fr rsr*k, Reliable Automatic Sprinkler Co.., Inc., I S.01.flhl IO¼ .#I Iak)IiC LI II# IVI%.J¼AI I II I I '.JI IO O.)I II II\II C LI.) c.piy water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model El and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design. and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model Fl FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm). of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model El FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Teôhnical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector! Orientation Nominal. Sprinkler Height Installation Wrench SIN mm Listings and Approvals Approval Notes US Metric inches mm inchesi F1FR28 2.8 40 3/8 10 Pendent 2.25 57 D RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent . 2.25 57 D RA1418 VdS Recessed Pendent 2.25 1 57 GFR2 RA14181 VdS F1FR42 4.2 60 7/16 10 Pendent 225 '57 D RA1413 cULus 2 Recessed Pendent 225 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2,25 57 D RA1410 cULus, NSF Recessed Pendent 225 57 GFR2 RA1410 cULus, NSF F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 1 57 D RA1423 cULus 1,2 F1FR56 5,6 80 1/2 15 Pendent 2.25 57 0 RA1414 cULus FM , , LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus FM , , LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 Conventional (Pendent or Upright) 2.25 57 D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 D RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 lRA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 . D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1 FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 D RA1485 cULus, FM, LPCB 1,2,3,9 " cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PIFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the Fl FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1 FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (7) cULus Listing of the Fl FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the Fl FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1070C) Max. Ambient Temp. 135°F(57°C) Temp. Rating 155°F (68°C) I Temp. Rating 175°F (79°C) Temp. Rating I 200°F(93°C). I Temp. Rating 286°F (141 °C) Temp. I Rating Orange Bulb I Red Bulb Yellow Bulb I Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- _________ Upright cULus Pendent VdS F1FR4O Recessed Pendent VdS I Pendent cULus F1FR42 Recessed Pendent cULus I -- _________ Upright cULus Pendent -- I cULus, NSF I I -- F1FR42LL Recessed Pendent -- I cULus, NSF -- Pendent cULus F1FRXLH Recessed Pendent cULus I -- _________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- I F1FR56 Concealed Pendent* cULus I cULus,VdS,EC cULus I -- Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright LPCB, VdS, EC Pendent -- cULus, NSF I -- F1FR56LL Recessed Pendent -- I cULus, NSF I -- _________ Concealed Pendent" -- I cULus, NSF I -- Horizontal Sidewall cULus, FM Fl FR56 Recessed Horizontal I cULus, Lus, FM I -- Fl FR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Model (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus FM LPCB, cULus, VdS, EC RA1414 EC VdS,EC F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM I cULus RA1435 Ell 2 7/4' HOLE OH. [57.2mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS -\ Fl ESCUTCHEON]_ 3/4719mm] ADJUSTMENT P2 ESCUTCHEON 1/2712.7mmj ADJUSTMENT f I" X 1/2 REDUCER FACE OF FITTING TO PACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 '[25.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4779mm] 77-777-771 AT MINIMUM RECESS = 3/879.5mm] Fl ESCUTCHEON AT MAXIMUM RECESS = 7/8722.2mm] I AT MINIMUM RECESS = 1-5/8 "[41.3mm] F P2 ESCUTCHEON I AT MAXIMUM RECESS = 1-1/8728.6mm] AT MINIMUM RECESS = 1-5/8741.3mm] 2 27/32 OH. (72.2mm] Fig. 1 Model Fl FR56, Fl FR56LL, Fl FR42, El FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon 1 X 1/2 REDUCER 2 58DL4. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP CEILING FACE OF FITTING FACE OF CEILING DIMENSION L I;wi__ ' MAXIMUM : ECES : = 1-1/2738mm] AT MINIMUM RECESS 1 "(25.4mm] Y2"[12.7mm] J AT MAX/MUM RECESS = 9/16714.3mm] ADJUSTMENT 3 1/4"D/A. (82.6mm] Fig.2 Model Fl FR56, Fl FR56LL, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model FP escutcheon 61 FACE OF FITTING ro FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = .3/8'r9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE DIA. [57.2mm] 1" X 1/2" REDUCER r [.3 1/8" .2mm] Fl ESCUTCHEON AT AlA WAAIIAA D('C - 1_ /Q"f A Th fli fVIfl#UVflJIVlfl LI,,L.JO - Jf c L "" AT MINIMUM RECESS = 2- 1/16"[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[4 1.3mm] AT MINIMUM RECESS = 2- 1/16[52.4mm] 15/16" DIA. 4JJ [49.2mm] iuhi 11111 TURN COLLAR UNTIL - TIGHT AGAINST SPRINKLER WRENCH BOSS. MIllIllIll1 2 27/32" DIA. [72.2mm] 'I ' Fl ESCUTCHEON j 3/4 "[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2 "[12.7mm] ADJUSTMENT (1) 4"-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR OAJI7E RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model El FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW 1.11] :Iii} 2 5/16" 0/A I I: l I HOLE IN CEILING CUP I,, CEILING j" 1/2" MAX. COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER 1 1/2" MAX. FACE OF FITTING ..TO FACE OF CEILING DIMENSION 15/16" CONCEALED, 1/2" ADJUSTMENT 0I7FGOIA Fig. 4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate I" x 1/2" REDUCING TEE OR ELBOW ____ 25/8 0/A. 2 5/16 0/A HOLE IN CEILING CUP O3VI 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING CEILING DIMENSION 5116" MAX. / 3/4 COVER ADJUSTMENT COVER PLATE— / j ASSEMBLY _ 3 5/16" 0/A. SPRINKLER CONCEALED, 5/16" ADJUSTMENT Fig. 5- Model Fl FR561F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler IEscutcheon Cover plate1 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(50) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate0 Electroless Nickel PTFE7 Electroless Nickel PTFE Bright B rig Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint2t6 Black Paint I Off White Off White(2P) Off White Satin Chrome Chrome Dull Chrome Dull (') Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. ' cULus Listed only. (3) 200°F (93°C) maximum. " cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. )°) LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. )?) cULus listed Corrosion Resistant 7 Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PIFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR4O][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [U prig ht] [Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall] [Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (570C)][1550F (68°C)] [175°F (79°C)] [200°F (93°C)][286°F (141°C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (570C)for use with Ordinary Temperature sprinklers][ 165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors-test connections Sight drains Ball drips, and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. is Recycled ® (800) 431-1588 Sales Offices Paper Reliable (914) 829-2042 Corporate Offices (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 12/15 P/N9999970300