HomeMy WebLinkAbout5927 BALFOUR CT; ; AS0501889/12/23, 9:59 AM AS050188 Permit Data
City of Carlsbad
Sprinkler Permit
Job Address: 5927 BALFOUR CT
Permit Type.: SPRINK
Parcel No: 2120701300
Lot #: 0
Reference No.:
Permit No: AS050188
Status: APPROVED
Applied 9/22/2005
Approved: 9/22/2005
Issued: 9/22/2005
PC #: Inspector:
Project Title: ATTILA FIRE SPRINKLER PLAN CHECK & INSPECTIONS
Applicant:
WEST COAST FIRE PROTECTION
271 ROYMAR RD
SUITE F
OCEANSIDE, CA
(760)754-8472
Owner:
SW BALFOUR LLC
26840 ALISO VIEJO PKY #100
ALISO VIEJO CA
Fees ($) Add'l Fees ($) Total ($) Balance ($)
120 0 .120 0
about:blank 1/1
many angles, reducing
assembly effort. This sprin-
kler is available in various
temperature ratings (see
chart on page 2) and fin-
IsheS to meet many design
requirements.
The recessed pendeni
should be utilized with a
Model V27 recessed
escutcheon which pro-
vides up to VV (19 mm) of
adjustments.
Sprinkler Operation
The operating mechanism
Is a frangible glass bulb
which contains a heat
responsive liquid. During a
fire, the ambient tempera-
ture rises causing the liquid
in the bulb to expand.
When the ambient temper-
ature reaches the rated
temperature of the sprin-
kler, the bulb shatters. As a
result, the waterway is
cleared of all sealing parts
and water is discharged
towards the deflector. The
deflector is designed to dis-
tribute the water In a pat-
tern that is most effective
in controlling the fire.
Coverage
For coverage area and
sprinkler placement, refer
to NFPA 13 standards.
Asol~;cltsS
V27, K5.6
Models V2703, V2704, V2707 and V2708
Standard Spray
Upñght, Pendant and Recessed Pendant
Standard and Quick Response
PRODUCT DESCRIPTION
These Model V27 standard
spray sprinklers are
designed to produce a
4vZ=7
hemispherical spray pat-
tern for standard commer-
cial applications. They are
available with either stan-
Recessed dard or quick response
Pendent bulbs. The design Incorpo- (j) () •
rates state-of-the-art, heat
responsive, frangible glass
SW Vktat4c
mmwn 10.01
bulb design (standard or
pu
fWdetallL quick response) for prompt, vzioi V27M precise operation.
The the cast frame Is more W streamlined and attractive
th traditional sand cast
Pendent frames. It Is cast with a
V2703 hex-shaped wrench boss to
VZVOK4 • allow easy tightening from
Upright
TECHNICAL SPECIFICATIONS
Models: V2703. V2704. V2707.
V2708
Style. Pendent. Upright or
Recessed Pendent
Nominal Orifice Size: 14 (13 mm)
K-Factor: 5.6 Imp. (8.1 S.L")
Nominal Thread Size:
W NPT (15 mm)
Max. Working Pressure:
175 psi (1200 kPa)
Factory Hydrostatic Test
100% @ 500 psi (3450 kPa)
Mm. Operating Pressure:
7 psi (48kPa)
Temperature Rating See
chart on page 2.
MATERIAL
Upright Deflector. Bronze per UNS C22000
Pendent Deflector:
Bronze per tINS C5 1000
Bulb: Class with glycerin solu-
tion.
Bulb Nominal Diameter.
U Standard: 5.0 mm
U Quick Response: 3.0 rum
Load Screw:. Bronze per tINS
C65100
Pip Cap: Bronze per UNS
C65 100
Spring: Beiylliuiu nickel
Seal: Teflon* tape
Frame: Die cast brass 65-30
Lodgement Spring:
Stainless steel per tINS 530200
ACCESSORIES
Installation Wrench:
U Open End: V27
U Recessed: V38. V38-3
U Socket: V27
Finishes:
U Plain brass
U Chrome plated
U White painted"
U Custom palnted**
U Lead
155,200. 286SR Only:
U Wax
U Wax over (ead**
For cabinets and other accesso-
ries rerer to separate sheet.
NOTE Weather redstart recessed
esca1cheons available upon request.
For K-Facto, a$len pressure is mea-
sured In Bar, rntdiiiy S.l. units by
10.0.
Tcflon is a registered trademark CA
0uont Co
UL Listed for corrosion resistance In
all conilgurafims.
VICTAULICO IS AN ISO 9001 CERTIFIED COMPANY
Victaullc Company of America Vlctaulic Company of Canada Victaullc Europe Vlctaullc America Latina Victaulic Asia Pacific
Phone: 1-800-PICK-VIC(1-800-742-5842) Phone: 905-884-7444 Phone:32-9-381.1500 Phone: 610-559-3300 Phone: 65-6235-3035
Fax: 610-250-8811 Fax: 905.884.9714 Fax: 32-9.3804438 Fax: 610-559-3608 Fax: 65-6235-0535
e-mall:plckvIcvictauliccom e-mail:viccanxa@viciautic.wn e-mail:viceuro@victatilic.be e-maiLvkal@victauUc.com e.mall: vicap@victaulic.com
2544 Rev.O am 0 RegIsaredTmdeiiakc1VIctsic 0Cp)llgIz2003 vlcudic PINWInusiL
APPROVALSILISTINGS
Nominal . Approved Temperaturó Ratings OFPC $ fl
OdflC Size K-Factor kiches frnpedal DeSector
Model mlllitneisiw W Response Type UI. FM ULC NYCJMEt CSFM
V2703 ½ 13 5.6 :
8.1 Standard Upright 135-360 57-182 135-360 57-182 .135 - 360 57-182 135-360 51-182 135-360 57-182
½ 5.6 135-360 135-360 135-360 135-360 135-360 V2707 13 81 Standard Pendent 57-182 57-182 57-182 57-182 57-182
V2707 ½ 5.6 : Standard Recessed Pendent 135-360 135-200 135-360 135-360 135 -360
13 ai Up to W Aatmo1 57.182 57-93 57-182 57-182 57-182
½ 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8.1 : Quick Upright 51-141 57-141 57-141 57-141 57-141
½ 5.6 135-286 135-286 135-286 135.286 135-286 V2708 13 8.1 . Quick Pendant 57-141 57-141 1 57-141 57-141 57-141
V2708 ½ 5.6 Quick Recessed Pendent 135-200 135- 200 135- 200 135-200 135- 200
13 8i Up to WMJustment 57-93 57-93 57-93 57-93 57-93
V2708 ½ 5.6 Quick Recessed Pendent 135-200 NO 135-200 135-200 135-200
13 8.1 . Up LOW Adjustment
-
-S7-93 57.93 57.93 5793
Uslings and approval as ir printing. UPJI are approved open. excepr ror areas designated N0.
For K-Factor when pressure Is measured In Bar. multiply Si. units by 10.
I MEA #62-99-E. § CSFM #1890.0531:112
RATINGS
All glass bulbs are rated for
temperatures from -67°F
(-55°C) up to those shown
in adjacent table.
Tempsraba'e— 'FI°C
Sprinkler Victaulls Nominat Maximum Glue
Temperature Pad Temperature Ambient Temp Bulb
Classification Identification Rating Allowed Color
Ordinary A 135 57 100 38 Orange
Ordinary C 155 68 100 38 Red
Intermediate E 175 79 150 65 Yellow
Intermediate F 200
93
150 65 - Green
High -
286 141 225- 107 Blue
Extra High I K 360
182
300 149 Purple
4 M Open : No Sub
I Standard response only.
Al are approved open, except for areas designated No.
- 150/65 if wax coated.
ORDERING INFORMATION
Please specify the following
when ordering: U Sprinkler Model Number U K-Factor U Sprinkler Finish
U Style U Thread Size U Escutcheon Finish
U Temperature Rating U Quantity U Wrench Model Number
AIwaysmad and wzie,staidkistaUathtm care, aid maint einslmctians, dwthe di*leis.bekreproceedlnginthhistalialion
of any sprii*Iers
- • Always wear solely glasses and Foutpateclion.
Depressurize aid drain the piping system before attempting to Install, remom or adjust any Victa*lic piping products.
00 • liutallationndes. especially these governing obstruction, must be strictly followed.
Panting, plating, or my re-coaling of sprinklers (other than that supplied byvictaulic) is not allowed.
Failiteto follow these lnssiuc*ions could result In serious personal lipoy arty property damage.
The owner Is responsible for mainIabdng on fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, rater to the current National Fire Protection Association paiipiitel that describes care and maintenance of sprinkler systems. In additin the authority bavingjwisdctlun may have additional
maintenance, testing, and inspection reqitreninla that carat be followed.
If you need additional copies of this publication, or if you have any questions about the sate installation of this product, contact Vlctaihc Wend Headivartaa, P.O. Box 31, Eagan, Pennsylvania 18044.0031, 610-559-3300.
40.10-2
~
(24 mm) 4i.'
H '4r 1"As
(43 MM)
I
Typlool CeMag Tile
(33mm)
Flelelied Sw ce (24—)
MAXIMUM RECESS
DIMENSIONS
(41 mm)
(60 mm)
Wl
Standard Pendant- V2707. V2708 Standard Upright -V2703, V2104
Typleol ceangno ____
p
7'
I9ZV I
.-. Surbw r
MAXIMUM RECESS I
L 2~
MAXIMUM EXTENSION
W Adjustment
Recessed - V2707. V2708
(Drawing not to scale)
2'w (75mm)
MAXIMUM EXTENSION
%' Adjustment
Recessed - V2701. V2708
(Drawing not to scale)
AVAILABLE WRENCHES
V27
Socket
V38 orV38-3
Recessed
V27
Open End
V2707.V27O8Pendent
V2707, V2708 Recessed Pendent
V2703. V2704 Upright
40.10-3
DISTRIBUTION PATTERNS
MODELS V2707, V2708
K5.6 STANDARD PEMENT AND RECESSED PENDENT
DISTRIBUTION PA1TERNS —TRAJECTORY
10'
3,0 m
8'
2,4 at
6'
1,8m
4'
1,2 m
2'
0,6 m
a
7_
48 kPa
15 psi
103 kPa
30ps1
207 kPa
\.\ '
10' q.
3.0m
2,4 m
1,8 m
1,2m
2-
0.6 m
0 -
2' If & 8' 10' 12 14'
0,6m 1,2m 1Mm 2,4m 3,0m 3,7m 4,3m
MODELS V2703. V2704
K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY
2' 4 6 8' 10' IT 14' 16'
0.6m 1,2m 1Mm 2,4m 3.0m 3.7m 4,3m 4,9m
7psi
48 kPa
15 psi
103 kPa
30 psi -------
207 kPa
NOTES:
Data shown is approximate and can vary due to differences In installation.
These graphs illustrate approximate trajectories. floor-wetiing. and wall-wetting patterns For these specific Viclaulic FireLock Automatic Sprinklers. They are
provided as Information For guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for Installation. ReFer to
the appropriate NFPA National Fire Code and the authority havingjurisdicrton rot specific Information regarding obstructions, spacing limitations and area of
coverage requirements. Failure to follow these guidelines could adversely affect the performance or the sprinkler and will void all Listings. Approvals and War-
ranties.
All patterns are symmetrical to the centerline or the waterway.
WARRANTY Refer to the Warranty section
of the current Price List or
contact Victaulic for details.
This product thai be utanurachEeci by Vir:latihc Cairpany. Ni products to be installed in accordance with ctsrest Viclaulic InstalloWhissanbly nstftKUons
Victaulic naorves ibeiigtti to change product spociflcaiions, designs and standard aqtmest without nolioo and twihoig Imuning obllgallons.
40.10-4