Loading...
HomeMy WebLinkAbout1610 BUENA VISTA WAY; ; FPR2018-0126PERMIT REPORT (itY of Carlsbad Permit No: FPR2018-0126 Print Date: 09/07/2023 Job Address: 1610 BUENA VISTA WAY, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel U: 1561426000 Track #: Valuation: $598,073.20 Lot #: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check #: Status: Closed - Finaled Single Family Fire Sprinkl Applied: 07/03/2018 Issued: 07/17/2018 DEV13013 Finaled Close Out: 09/10/2019 Final Inspection: INSPECTOR: Salcedo, Felix Wong, Cindy Project Title: KING PROPERTY Description: PACIFIC LEGACY: NEW 2-STORY SFD - SPRINKLER 13D (35 HEADS) FPContractor: INNOVATIVE FIRE PROTECTION INC 8779 COTTONWOOD AVE, U 101 SANTEE, CA 92071-4457 (619) 593-8200 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 Total Fees: $360.00 Total Payments To Date: $360.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov HYDRAULIC CALCULATIONS for Job Information Project Name: BUENA VISTA COLONY, LOT 4 Contract No. : C7065 City: CARLSBAD, CA 92008 Project Location: 1610 BUENA VISTA WAY Date: 6/29/2018 Contractor Information Name of Contractor: INNOVATIVE FIRE PROTECTION, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 E-mail: DERIK@IFPINC.NET Name of Designer: DERIK BROOKS Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name 1 Remote Area Location 2ND FLOOR HALL Occupancy Classification NFPA1 3D o 00 clo Density (gpm/ft2) . . 0.051 T— oo C1'til coç _ Area of Application (ft2) 512 u Cv) ' Ci) Coverage per Sprinkler (ft2) 256 f.2 CD L0 Number of Calculated Sprinklers 2 zz > 00 In-Rack Demand (gpm) 0 0 cps1 Special Heads Hose Streams (gpm) 5 0 Total Water Required (incl. Hose Streams) (gpm) 31 w 5 LL Required Pressure at Source (psi) 49.6 Type of System Wet co Volume- Entire System (gal) 2 5.9 gal 0 C10o 0 Cv) > Water Supply Information W Date . 6/29/2018 U. Location SITE Source I Notes File: C7065 BUENA VISTA COLONY, LOT 4_1_1_8006.v$ Date 6/29/2018 Copyright 0 2002-2012 Tyco Fire Protection Products Page 1 Supply I : 1 Préssuré(Psi. .0 Supply Analysis Job: BUENA VISTA COLONY, LOT Hydraulic Analysis for: I CalCulation Info CaIculaon Mode Hydraulic Model Fluid Name Fluid Weight, (Ib/0) Fluid Dynamic Viscosft', (lb/ft2) Demand HaehWillims Water © 60F (15.6C) N/A for Hàzen-Wliliams talculeition. N/A for Hazen-Wiiliams cakulátión. -.. _- .. .. .... Water Supply Parameters 8t Total bemand Required Pressure L:: 0 [StaticPressure:o [ 1 576 62 900 576 31 496 Hoses Inside HosO Flow! Standpipe Demand (gpm) OUtside Hose Flow (gpm) AdditIonal Outside Hose Flow (gpm) Other (custom defined) HOSe Flow (gpm) 0 . Total Hose Flow (gpm) 5 Sprinklers Ovehe8d Sptinkler Flow (gpm) 26 InR3ck Sprinkler Flow (gpm) Other (óustom defined) SpriklOr Flow (gpm) 0 .... SiSi,NflS.à.iS ........IS. ........S ...........55.... Total Sprinkler Flow (gpm) 26 Other Required Margin of Säfeiy (psi) 0 I Prssure (psi) 475 Plow (gpm) 31 bemand W/o System Pump(s) N/A File: C7066 BUENA VISTA cOLONY, LOT 41_1_8006sv$ Date 6129/2d18 CopyigntC 20022012 Tyco FIrS Protection Poducta Page 2 Job: BUENA VISTA COLONY, LOT 4 Hydraulic Analysis for: I Supply * System Demand D2 49.i754 40- CL *4 .# M*4Mn .S 4.n*san 0 30-- C, — .................- .-.. .................... - ......................-,. ...................... .............................................. 20-.-- --- - Dl - - --- -- (.4fl W&WSM.c..c__flflfl* Vmtfl#fl*4*MnS.t.4flt.*8flW..O.....4 M$efl**.P*Snn.nflaMn......can...n€nn 0- 0 200 300 400 500 -600 Flow, gprn File: C7065 BUENA VISTA COLONY, LOT 4_1_1_8006.sv$ Date 612912018 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job: 6UENA VISTA COLONY, LOT 4 Hydraulic Aflaiysi for I Graph Labels Label Desdtiption SI SupØlypoint#1 Womb 576 S2 . pply point #2- Reidul ;611elvatioh 500 -. 52 DI Pressure 0 8 7 D2 . . .- System Demand - -... 31 496 -.... Curve intersections & Safety Margins Interseetlon. - - Safety Margin ow (gpm) Supply . 5:6 . - I 34.2 I 8 . .@ 31 Open Heads Head Ref. Head Type Cbveage Required Calculated ensity . KPator Flow Pressure Density Flow -. Pressure . (ft) .-- (gpnvp½) (gprn/f) ..-. (gpj) psI) --'.-,--.---- (gpm/ft) -----.- . (pm) .-------.----- (psi) 101 256 4.9 6.0 12.8 0.O51 11 . - .. 7.1 102 256 4,9 0.05 .---. 12.8 1 0.01 13 7 File: C7065 BUENA VISTA COLONY, LOT 4_1_1_8006.sv$ Date 6(29/2018 Copyright 0 2002-2012 TycO Fire Protection ProductS Page 4 Job: BUENA VISTA COLONY, LOT 4 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/ps11/2) (gpm) (In) (ft) (ft) (psi) (psi) Path No: I 102 19 4.9 13 1 lx(BM.Tee-Br)=5 11.48 150 7 45 20 13 1.101 ix(BM.90)=5 10 0.0304 -0.4 21.48 0.7 45 20 -3.7 1 4x(BM.Tee-Run)=4 29.53 150 7.2 30 20 9.3 1.101 lx(BM.Tee-Br)=5 14 0.0164 0 1x(BM.90)=5 - 43.53 0.7 30 20 5.7 1 1x(BM,Tee-Br)=5 12.74 150 7.9 26 10 15 1.101 2x(BM.90)=10 15 0.0399 4.3 27.74 1.1 26 10 1.4 1 ±x(BM.teë-Run)=1 8.18 150 13.4 13 10 16.4 1.101 1x(BM.Tee-Br)=5 6 0.0468 0 14.18 0.7 13 10 9.7 1 lx(coupling)=1.91 25.74 150 -14 - 4-0 5.5 26 1.101 3x(BM.90)=15 17.91 0.1105 1.9 lx(BM.Tee-Run)=1 43.65 4.8 4-0 5.5 0 1 0.5 0 20.8 BRASS RESI 4-1 5 26 0 0 10.7978 0.2 *** 0.5 5.4 4-I 5 0 1 lx(coupHng)=1,91 3 150 26.4 3 2 26 1.101 1.91 0.1105 1.3 4.91 0.5 3 0 1 lx(coupling)=1.35 4.5 150 28.3 3A -1 26 1.025 lx(us.90)=2.7 4.05 0.1565 1.3 8.55 1.3 3A -1 0 1.5 3x(us 90)=18 12 87.87 150 30.9 2A -1 26 1.61 18.12 0.0174 0 105.99 1.8 2A -1 5 1.5 lx(coupling)=;1.51 1 150 32.7 BF-0 -1 31 1.61 1.51 0.024 0 2.51 0.1 BF-0 -1 0 1 0.5 0 32.8 WILKINS BF-I -1 31 0 0 12.1915 0 950XL 0.5 6.1 *** BF-1 -1 0 1 lx(coupling)=1.35 0,5 150 38.9 2-0 -1 31 1.025 1.35 0.2167 0 1.85 0.4 2-0 -1 0 1 0.5 0 39.3 WATER METER 2-I -1 31 0 0 8 04 0.5 4 *** 2-I -1 0 1 25 150 43,3 1 -1 31 0.995 0 0.2505 0 25 6.3 1 49.6 File: C7065 BUENA VISTA COLONY, LOT 4i,18006.sv$ Date 6/29/2018 Copyriht© 2002-2012 Tyco Fire Protection Products Page 5 Job BUEN? Path No; 101 40 40 39 39 18 18 13 Path No Path No: 45 20 0 1 4x(BM.Tee-Run)=4 - 32.23 iSO 7.2 40 20 3.1 ii0i ix(BM,90)=5 9 0.0029 0 41.23 0.1 40 7.3 Path No: 5 39 2 0 0 1 2x(BM.The-Br)=10 54.23 150 7.4 0 20 5.7 1.101 Sx(8M.TeeRun)5 20 0.0067 0 1x(BM90)5 74.23 0.5 30 7.9 Path No: 6 18 10 0 - I 5x(BM.Tee-Run)=5 53.74 150 13.3 26 10 1.4 1.101 1x(BM.90)5 15 0.0005 0 6834 0.0 26 134 r--- ----. -. * pressures are balanced to a high degree of accuracy. values may vari by 0i psi due to display rounding. * Maximum Velocity of 12.81 ft/s occurs in the following pipe(s): (124) Device pressure loss (gain in the case Of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as Shown in the table above comes from the CAD drawing. The friction loss per unit of length IS calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but IS an individual item whose loss/gain is based solely on the curve data, File: C7065 BUENA VISTA COLONY, LOT 4_1_1_8006.sv$ Date 6129/2018 Copytiqht 0 26022012 Tyco Fire Protection Products Page 6 Job: BUENA VISTA COLONY, LOT 4 Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: 1; Supply Name:1 ._ii i_ ::x"ii 40 ... ........ ...........................................................-.-..----..---,*----.--------.-............-.-- 25 20.- . ..- tO.5 ...---.- ......-.-'-.....---.-.-----..--.-. -..- o 0 0 0 0 0 0 m Flow, gpm Pressure Loss Function Design Area: 1; BFP Ref.: 128 (WILKINS 950XL, Size = 1); Inlet Node: BF-I; Outlet Node: BF-0 0 0 0 0 0 0 0 Flow, gprn File: C7065 BUENA VISTA COLONY, LOT 4j1,8006,sv$ Date 6/29/2018 Copyright 0 20022012 Tyco Fire Protection Products Page 7 Job BUENA VISTA COLONY, LOT 4 Device Graphs Pressure LOSS Function Deéign Area: 1; Valve Ref: 121 (WATER METER 4 Size = 1); Inlet Node 2-I; Outlet Node: 20 39 2.9 0 2.4 0 U) 0.. 1.9 1.4 0.9 OA 1.1.1....[I ........ . . .. .. 0 0 b 0 Flow, prn Pressure Loss Function Design Area 1; Valve Ref: 129 (BRASS RESI, Site 1); Inlet Node: 4-1; Outlet Node: 4-0 0 Mow, qpm Pile: C7065 BUENA VITA COLONY; LOT 41J8006.sV$ Date 6/29/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 6 HYDRAULIC CALCULATIONS for Job Information Project Name: BUENA VISTA COLONY, LOT 4 Contract No. : C7065 City: CARLSBAD, CA 98008 Project Location: 1610 BUENA VISTA WAY Date; 6/29/2018 Contractor Information Name of Contractor: INNOVATIVE FIRE PROTECTION, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 Email: DERIK@IFPINC.NET Name of Designer: DERIK BROOKS Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name 2 Remote Area Location BEDROOM 3 Occupancy Classification NFPAI 3D Density (gpm/ft2) 0,053 Area of Application (ft2) 400 Coverage per Sprinkler (ft2) 400 Number of Calculated Sprinklers In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 26 Required Pressure at Source (psi) 54 Type of System Wet Volume - Entire System (gal) 24,9 gal Water Supply Information Date 6/29/2018 Location SITE Source Notes File! C7065 BUENA VISTA COLONY, LOT 41I_8006.v$ Date 6/29/2018 Copyright © 2002-2012 Tyco Fire Protection Product Page 1 Supply I I ..-!0w (gpn) ,.. . Pressure (psi) L . 0 . . 576 [T 500 ... 62 Supply Analysis Job: BUENA VISTA COLONY. LOT 4 Hydrimlic Analysis for: 2 Calculation Info Cakuietlon Made Hydraulic Model Fluid Narie Fluid Weight, (lb/ft) Fluid byn6nc VlcoSfty, (lbs/ft) Demand Hazen-Williams Water Qb 60F (15.6C) N/A for HazeriWi Warns caiculäiän. N/A for H .ori-Wflllarns càIcUIation J.---- — - Water Supply. iarameters d. Nodbat Ourc! Sthtic Pressure T Flow Pressure f5 . !klable 4 Tbtal ;r 4Required S7 54 ., .- .--.,-, --.----.---- -.-.---------.--- Hoses Inside Hose Flow I Standpipe Demard (gpm) Outside Hose Flow (9pm) Additional Outside Ho 'ad Flow (gpm) Other (custom defined) Hose FIw (OM) 0 eSdufl Total HoSe Flow (gpm) 5 Sprinklers Ovoiead Sprinkler low (qpm) 21 lñRack Spnnkler Flow (gpm) Other (cuetoh defined) Sprinkle PlOw (pm) Totil Sprinkler Flow (gpm) 21 -. - - Other Required Margin of Safety (psi) 0 I - Pressure (psi) 54 Flow (9) 26 Demand wio System Pump(s) N/A File: C7065 BUENA VISTA COLONY, LOT 41j8006.sv$ Date 6/29/2018 Copynght 0 2602-012 Tyco Fire ProtCction Products Page 2 Job: BUENA VISTA COLONY, LOT 4 Hydraulic Analysis for: 2 Supply .' System Demand SI D2 I S2 I 541 a) .---- -- _ --- - - - ---- -_--.. -_- - Cl) Cl) 30-- - ss m a. nn.nns_nwn 200 300 400 500 L-11112 10 Flow, gpm File: C7065 BUENA VISTA COLONY, LOT 4_1_1_8006.sv$ -Date 6129/2018 Copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job I ouem VA o6LONY, LOT 4 Hydraulic Analysis for: 2 Graph Labels Label Oesription Values Pressure (psi) Si Supply point #1 -Static 0 57 S2 Supply point #2- Reidul 500 52 Dl Elevation Pressure 0 8.7 02 ISYSt6M Demand 26. 54 Curve Intersections & Safety Margins Curve Name ntersectibn Safety Margin Pressure (psi) Flow (gpm) pressure (psi) © Flow (gpm) Supp!y 5?6 27,1 3.6 26 Open Heads ReqUired Calculated Head Ref. Head Type Coverage Density -. Flow K-Factor Pressure -- Density -.--..-.----..-- Flow Pressure (ft) (prn/psIVa) (Jpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 195 Overhead Sk 400 4.9 0,05 20 18.4 0.0 21 - 18.4 File: 01065 BUENA VISTA COLONY, LOT 411,,8006.sv$ Date 6/29/2018 CoyIight 6 2002012 1,co Fife Protection Products Page 4 Job: BUENA VISTA COLONY, LOT 4 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/ps11/2) (gpm) (in) (It) (It) (psi) (psi) Path No: I 195 19 4.9 21 1 1x(BM.Teé-8r)5 1 150 18.4 44 20 21 1.101 5 0.0743 -0.4 6 0.4 44 20 -9.5 1 4x(BM.Tee-Run)=4 2169 150 18.4 39 20 11.5 1.101 lx(BM.90)=5 9 0.0245 0 31.69 0.8 39 20 -3.1 1 5x(BM,Tee-Br)=25 34.94 150 19.2 18 10 8.4 1.101 2x(BM.90)=10 35 0.0136 4.3 69.94 1 18 10 -0.7 1 4x(BM.Tee-Run)=4 - 30.58 150 24.5 13 10 7.7 1.101 lx(BM.90)=5 9 0.0116 0 39.58 0.5 13 10 13.3 1 lx(coupling)=1.91 25.74 150 24.9 4-0 5.5 21 1.101 3x(BM.90)=15 17.91 0.0743 1.9 lx(BM.Tee-Run)=1 43.65 3.2 4-0 5.5 0 - 1 0.5 0 30.1 BRASS RESI 4-1 5 21 0 0 8.3127 0.2 0.5 4.2 4-I 5 0 1 lx(coupling)=1.91 3 150 34.5 3 2 21 1.101 1.91 0.0743 1.3 4.91 0.4 3 2 0 1. 1x(coupling)1 35 4.5 150 36.2 3A -1 21. 1.025 1x(us.90)2.7 4.05 0.1053 1.3 8.55 0.9 3A -1 0 1.5 3x(us.90)18.12 87.87 150 38.4 2A -1 21 1.61 18.12 0.0117 0 105.99 1.2 2A -1 5 1.5 lx(coupiing)=1.51 1 150 39.6 BF-0 -1 26 1.61 1.51 0.0173 0 2.51 0.0 BF-0 -1 0 1 0.5 0 39.6 WILKINS BF-I -1 26 0 0 11.127 0 950XL 0.5 5.6 *** BF-I -1 0 1 1x(coupling)1.35 0.5 150 45.2 2-0 -1 26 1.025 1.35 0.1563 0 1.85 0.3 2-0 -1 0 1 - 0.5 0 45.5 WATER METER 2-I -1 26 0 0 8 04 0.5 4 *** 2-I -1 0 1 2515049.5 1 -1 26 0.995 0 0.1806 0 25 4.5 1 54 Path No: 2 G5 -1 5 1.5 1x(us.Tee-Br)=12.08 1 150 39.6 2A -1 5 1.61 12.08 1. 0.0008 0 13.08 _______ 0.0 2A 39.6 File: C7065 BUENA VISTA COLONY, LOT 4_1J_8006.sv$ Date 6/29/2018 Copyright 0 2002-2012 Tyco Fire Protection Products Page 5 Job BUENA VISTA COLONY, LOT 4 Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K'Fctor 1 HW added (q) NOmal ib Fittings L C Factor total (Pt) Node 2 Elev, 2 K-Factor 2 Total flow (Q) Actual ID quantity x (nathe) length Pf per ft elev (PC) NOTES T -'-- frict (Of) (ft) (gpm/psW2) (gpm) (in) (ft) . (ft) (psi) (psi) Path No: 3 44 20 0 1 5x(81YIJee-110)=5 - 40.06 150 18.4 - 30 20 9. 1.101 1x(BM.Tee-6r)5 iS 0.017 0 1x(6M9O)=5 5506 09 30 20 3.1 1 1x(BM.Tee-Br)=5 12.74 150 19.3 26 10 ±2.6 1.101 2x(8M90)=10 15 0.0288 4.3 27.74 - . 0.8 2 6 10 W 1 rx(BM.Tee-Run)i - 8.18 150 24.91 13 10 13.3 i;iOi i(BM.Tee13r)5 6 0.0318 0 13 24.9 Path No: 4 39 20 0 1 2x(BM.Tee-13r)=10 54.23 iSO 19.2 30 20 3.1 1.101 5x(BM.tee4Run)=5 20 0.0022 0 l)((BM 90)5 74.21 0 2 30 19.3 Path No: S 16 10 0 1 (B eRuh) S 53 1 150 24.5 26 10 0.7 1.101 1x(6M90)5 15 C.-0001 0 68.74 . . 9 26 . - 24.5 * Pressures are balanced to a hiti degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 1074 s occurs in the following pipe(s): (1-2I) *** Device pressure loss (gain in the case of pumps) Is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated bated upon the length and the curve-based loss/gain value. IhternaI ID and C Factor values are Frelevant as the device is not represented as an addition to any pipe, but is an Individual item whose loss/gain is based Solely on the curve data. Flk. C7065 BUENA VISTA COLONY, LOT 4_11_806.sv$ Date 6/29/2018 Copydght 0 002-012 lyco Fire Protection Products Page 6 Page 7 Job: qUENA VISTA COLONY, LOT 4 Device Graphs Pressure vs. Flow Function. Design Area: 2; Supply Ref.: 1; Supply Name:1 CD 0 0 0 0 0 00 0 0 0 0 eq Flow, gpm Pressure Loss Function Design Area: 2; BFP Ref.: 128 (WILKINS 950XL, Size = 1); Inlet Node: BF-l; Outlet Node: BF-0 5.6 psi @26gpm 0 2 Flow, gprn File: 07065 BUENA VISTA COLONY, LOT 4j.18006.sv$ Date 6/29/2018 Copyright 0 2002-2012 Typo Fire Protection Products Job: BUENA VISTA d0LONYj LOT 4 Device Graphs Pressure Loss Function Flow, gprn Pressure Loss Function Design Area: 2; Valve Rsf 129 (BRASS RESI Size = 1); Inlet Node: 44; Outlet Node: 4-0 iLl 10.1 9.' 8.1 t. 6.! b 4.t 3.1 2.1 0.1 ,.t,..4...Zk..,4.a . a*.4t4..1 ._ -... X....s,.k,:...,,...,... .__. .._. .....__........ - Xj PLJI. ..............z.:.r.................... : C P1 Pu Flow, gpm File: C7065 BUENA VISTA COLONY, LOT 4_I .I8OO6Sv$ bate 6129/2018 Copyright 0 2062012 Tyco Fire Protection Pr01ucts Page 8 FEATURES Sizes: 133/4" U 1" U 1-1/4" U 1-1/2" U 21- Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI 131.20.1 OPTIONS (Suffixes can be combined) U - with full port QT ball valves (standard) U L - less ball valves U U - with union ball valves U S - with bronze "Y" type strainer U TCU - with test cocks "vertical" up U V - with union swivel elbows (3/4" & 1") U OSY - with OS & V gate valves U FDC - with fire hydrant connection (2" only) U FT - with integral male 450 flare SAE test fitting APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical I 114"-2") GSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4") City of Los Angeles Approved (vertical 1-1/4-2") NYC MEA 426-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U QT-SET Quick Test Fitting Set U Test Cock Lock (Model TCL24) [iJ DIMENSIONS & WEIGHTS (do not Include pkg.) DIMENSIONS (a próximate WEIGHT MODEL A UNION BALL LESS WITH SIZE A BALL VALVES BALL BALL VALVES VALVES VALVES in. mm in. mm in. I mm in. mm in. mm in. mm in. mm in. I mm in. I mm lbs I jg Ibs 3/4 20 111/4 2861 121/2 318 7 178 11/2 38 3 76 31/2 89 3 76 15 381 5 2.3 7 3.2 1 25 121/4 311 137/8 353 7 178 11/2 38 3 76 31/2 89 3 76 173/4 451 8 3.6 12 5.4 11/4 32 151/2419 181/2 470 109/16 268 2 51 31/2 89 41/2 114 41/2 114 211/2 546 16 3 22 15 11/2 40 171/8435 191/8 4861109/16 268 2 5131/28941/2 114 41/2 114 223/4 578 16 7.3 22 10 2 50 181/4460 20 _1508110 9/16 268 2 5131/2 89 41/2 114 41/2 114 251/8 638 16 7.3 28 12.7 Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805-238-7100 Fax:805-238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11-2 Phone:905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222-5356) Website: http:llwww.zurn.com 10 IL 0 0 20 40 60 80 9.5 12.6 03 15 QS CK 50 100 150 200 250 5 0. 0 FLOW CHARACTERISTICS MODEL SSOXL 314' 11"i I 1/4' I I12 & 2" (STANDARD & METRIC) FLOW RATES (115) FLOW RATES (GFM) 0 Rated HOW (Estabshed by 5pprovat agendes) TYPICAL INSIALLAllON Local codes shall govern installation requirements; To be installed in accordance with the manufaoturer1s instructions and the látestedition of the Uniform Plur' bing Code, Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (62mm) above adequate drains with sufficient sift clearance for testing and maintenance. The installation shall be made so that no part of the unit can bO submerged. Capacity thru Schedule 40 .Pip Pipe size 'ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/4" 2 .,. 2_ 3 5 3/8" 3 ....4... 6 ., 9 1/2 .,.5 7 14 1 20 27 40 1 1/4" 23 35 47 70 1 idl 32 48 63 52 8 105 167 PROTECTIVE ENCLOSURE al 12" MIN; 30" MAX. DIRECtIoN OF FLOW 41 OIRECTION OF FLOW OUTDOOR INSTALLATION INDOOR INSTALLATION SPECIFICATIONS The Double Check Valve Backflow Preventer shall be ASSES Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze ASTM B 584), the seat rings and all internal polymers shall be NSP® Listed NorylTM and the seat diSc Olastomers shall be silicohe. The first and second checks shall be acces- sible for maintenance without removing the device from the line; The Double Check Valve Backfiow Preventer shall be a WILKlNS Model 950XL. WILKINS a Zurn company, 1141 Commerce Way, Paso Rabies, CA 93446 Phone:805238-7100 Fax:805-238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905-405-8272 Fax:905-4Q5-1292 Product Support Help Line: 8774ACKFLOW (871.222-5356) • WebsitO: http://www.zurn.com Page 2 of 2 Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi National Fire Products, LLC RESI-RISERTM The RESI-RISERTM is a pre-assembled, compact, attractive fire sprinkler riser unit for residential sprinkler systemsin accordance with NFPA 13, 13R and l3D The RESI-RISER'TM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESI-RISERTM to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet, Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPOT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESI-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESI-RISERI fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 1W', 1W', and 2" Style: Thread x Thread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent # 6,076,545 RESI-RISERTM Size Chart Description 1" 1W' - 1W' 2" Height* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2" Depth 3-1/2" 3-1/2" 3-1/2" 34/2- Drain Size 1/2" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve 0 National Fire Products, LLC (800) 528-7978 Pressure fieftef/lest andDrn How it Works orrndi Positln tatc PéSsui Pressure Loss Tables Nessurd LoSs In 1" Resi-Riser _ 12 10 0 10 t5 20 25 30 35 40 Flow (gpm) PressUre Loss in 11/4" Resi-Riser 10 Mer- 0 10 15 20 25 30 35 40 45 50 5 60 Mow (gprn) Pressure Loss In 14/211 Resi4lser elieving Pressure xceeding 15 Osi 1nuãi Open bralti r llow Switch Test In 0 10 15 26 28 20 95 40 45 SO 55 60 65 10 75 80 Flow (gpm) cked Closed for ydrOstatic test Pretsure Loss in 2" ResRher 0 15 25 39 45 55 65 15 85 95 NOW (gpm) 0 Ntoñ& Pire Produt, IIC (800) 528-78 1 Of U SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 49, SIN: SS8464 - GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2.5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 130; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70. LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (1 2.8mm) vertical adjustment This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained In accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval, Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U085160 Date Feb/09/2015 I —Lot No. © I Year of Manufacture - Jic-taotor: K4.9 E [Nsr Temperature Rating I 62FJ72C E / UL Mark or 175'F/79C Control No. 6P37 - Mark: NSF-61--C Ct1 2— %"(0 68trim) or 3-i4"(8311m) or 2- "sqieke (065mm) Body (Copper Alloy) Deflector (Phosphorus Bronze) Casket (PIFE) Fusible Metal (Solder) Heat Collector (Copper) Cover Plate Assembly FIGUREL1Modei RC-RES. &=_4. Page 2 of 8 TECHNICAL DA Approvals: cULjq Listed NSF-61-0 Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 178psi (121 bar) Discharge Coefficient (Nominal K-Factor)- K4.9 GPMIpsi112 (706 LPMlbar112) Temperature Rating: 162P (72°C) Sprinkler with 1407 (60°C) Cover Plate 1751 (79°C) Sprinkler With 162 (72°C) Cover Plate COlOr Code (Sprinkler) 162 (72°C) Uncolored 115 (19°C): White Color Code (Cover Plate) 1407 (6060): No Mark 162'F (72°C): White-Colored Mark Vertical Adjustment: 112 inch (128 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown Blacks Nickel, WOod Grain Custom Plraahes Custom dolor and custom pattern Over plats are available on special order. COntat a Senju Sprinkler representative with any custom orders Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure I COVER PLATE SPRINKLER (lop view) (Bottom view) OPERATION fLGmE 14.Mark!nqlC010r Code) In case of fire, the solder component that holds together the doveri Plate and thd Retainer meth. Then, the Cover Plate Is released at once. As a result, the Deflector drops down to the Intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, interhal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed On the affected by fi5 area (Ref. Pigure 2) Norrtial Condition iu Cover Plate Operation Sprinkler Operation Water Discharge FIGURE 2.OPERei ION PROCESS (The fiaureisfor Illustrative .nurose only) bocumèat No. U086160 bate - PablO 9/2015 Page :3 of 8 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RE$ are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some Instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RCRES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. if the sprinkler Is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this Onvironment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, 8828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13P or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Document No. U085160 Date . Feb/09/2015 Page :4of8 A minIrnuñi discharge 01PM/sqit. 4.01LPM/9q.m] over the "design area" comprised of the foul' most hydraulically dSmaHding Sprinklers for the actual covorágè areas beihg protected by the four sptinklers rABiA. NEPAI3D & 1 3 WE PIPE NYb4LJjJCDESiGN CM IAórModeiS$8_4G4 Maximum Ordinary. Intermediate CoverS e Maxum ¶emperature R5tlng Thmpertul'e Rdiinq Deflet6r Minimum Area Spacing 1$2F (72C) 11bF u79C) to iStallati0n Spacing Pressure Flow,,,) 'Premueelll FL ei 1 type Ft. mm, (m) GPM Psi GPM ft (m) Smooth 12x12 12 13 7.0 3 7.0 CeilingS (3.7x3.7) (3.1) (42) (048) (49) (0.48) .3/8 to 1/8 Inches. 1014 14 13 1.0 13 1.0 (4,3X4.3) (4.3) (492) . (0:48) (49.2) (0.48) parNFPA 16x16 16 .13 7.0 . 14. 8.2 13D,13R Concealed 8 (4.9X49) (4.9) (42) (0.48) (53,0) (0.67) Or 13 (2.4) Installed in beam 1818 18 17 12.0 18 13.5 3/8 to (5.5) (64.3) (0.83) (68.1) (0.93) 7/8 inches 20x20 26 21 18.4 ... . (61x8, 1) (6.1) (796) (1.27) bottom Of ... .-. beam . For coverage area d1rn9ns10n5 less thafl the above mentioned, it n99d5 to use the minimum required How for the Next Higher Coverage Area listed. Requirement IS basd on rninimiini flow in GPM/LPM from each srinkIer. The associated residual pressures are calculated usi69 the homiH9l K.-Factor. Refer to Hydr9uiiO Design Criteria Section fol' details. (C) For systems with ceiling typos arhooth fiat horizohtal, or beamed, or sloped, in accordance *ith the 2013 Edition of NFPA 131), 1314 or 19 as applicable. $nrinkler.Snacine .Critj The minimum spacing b9tweefl sprinklerS is 8 feet (2.4m). The niaximum spaOing béen sprinklers cannot go beyond the coverage area calculated by using the SpecifiC hydraulic 1act0rs. (Ref. Table A) INS TALJIA nON The Model RC-RES must be inCtalled in accordance With the follOwing instructions. MOPES Do not Use any sprinklers which have böeñ subjected to potential mechanical damage. Do not use any spdnklers Which show deformation or cracking In either the Sprinkler or the Protective Cap. Prior to installation, sprinklerS shOuld bO maintained in the original cartons and packaging until Used to minimize the potential for damage to sprinklers that would cause Improper Operation or non-operation. The Protective Cap must remain On the Sprinkler during installation and until the ceiling installation Is completed. The Protective Cap must be fehoved to place the sprinkler in service. Document No. U085160 Date eb/O9/2615 Page .• 5 of 8 Use a torque of to 14 ft.Ibs (9.5 to 19.0111m) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting fora better fit. Installina Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Space Here Do NOT Ave '" (6.4mm) Ov Over—Tighten on the kl kler o v t : co T tiv E E Tolerance Limit i# urf.. ro on the Groov of the S k t Mo.ntin Surface 2 %_((66Omm) ck Wrench Ceiling Hole Diameter CORRECT INCORRECTI ( : I FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until Its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening .the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No. U085160 Date , Feb/Q9/2015 Paoli 6 of E Sp(irikler He &otctive ca Step 1 Cog., etLyer,k Step 2 Hook by tuuig Pull down 1- - PROTECI1VCAP1REMO'VAL Cu mouritim (,C6 - f r 3- J" (0 83mm) %aua?e (16emm) FIGIJRE.ø NCOCT] CORRECTI PORREcT1. .FJGuREiJ64srALL4rioNJcoRREcrORiNcoRREclJ. bOcumènt No. U0851 60 bate Feb10 /2O15 CARE AND MAINTENANCE Page . 7 of 8 The following instructions must be implemented for the maintenance and service of the Model RO-RES, NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F14 V to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation In case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fiuids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment.: Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards, Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100°F /38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced, The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area and the same or lower flow ratings (as indicated under Table A Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, Including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No. U085160 Date .- Feb/09/2015 ORbEI.. PROCEDURE Page 8 of 8 When placing an order, please contact a local distributor with the following Information (Model Name, Specify, Temp. and Finish). Sprinkler Model: RCRES (SIN: 5S84641 ResIdential Flat Concealed 8prinkl6r, Pendent, K4.0, temperature: 162F (72°C) or 11 5T (7900)) Cover Plate Assembly- 2-5/8 inch (68rn) or 3-1/4 inth (83mrn) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below foi available sizes, temperature, and finishes Standard Finishes Custóm Finithes White Ivory Beige Brown Black Nickel Wóbd grain Custom Color Custom Pattern Round, 9°!. .Pi. ..Q. ___ . ... 9. 3-1/4" Round 140°F C) 0 0 0 0 0 0 0 0 25/8 Square, i40bF 0 - - - 0 0 2-5/8' Round, 162°F 0 - 0 0 3-1/4" Round, 162°F 0 - - ---. 0 0 Tools fOr kitaIlatlon of MOdeh RORES Socket for Model RC-RS Wienh & Socket for Model RC-RS Cap Remover RC bocument No. U085160 bate : Feb/09/2015 Res 30. Recessed Pendent I Fl Recessed Pendant / FP Fl Res 30, 49, 58 & 76 CCP Penclen Fl Res 44SWC Recessed HSW/F2 Bulletin 135 Rev. M Rellabi-e Model F1 CD Residential Sprinklers for Design Density of .05 gpmfft2 Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpnVW Types: Fl Res 30Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/F1 Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendant Fl Res 58 Recessed Pendant/Fl Fl Res 58 Recessed Pendent/FP Fl Res 76 Pendent Fl Res 76 Recessed Pendent/171 Fl Res 76 Recessed Pendent/FP Fl Res 30 CCP Pendent Fl Res 49 CCP Pendent Fl Res 58 COP Pendent Fl Res 76 COP Pendent Fl Res 44HSW . Fl Res 44 Recessed HSW/F2 Fl Res 58HSW Fl Res 58 HSWX KRes58 HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44 SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,5 16,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7,353882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- on needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflectpr, evenly distributing the discharged water to control a tire. Technical Data: Thermal Sensor: Soldered element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: /2" NPT (R½) K-Factor: 3.0 (43.2) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Spnklr 5.8 (83.5) (Actual) - Fl Res 58 Pendant & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent Sprinkler 4.4(63) (Actual) - Fl Res 44 HSW Spnkler Density: Minimum 0.05 gpmlft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model rl Aes Sprinklers are Used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizohtal, or beamed, or sloped, in accordance with NFPA 13D, 1 3, or 13 2013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance With the latest published standards of The Na' tiorial Fire Ptotectiori Association Or the approving authority having jurisdiction. instaliaflôn Models P1 Res sprinklers are to bO installed 6b shOh. Model Fl P2 and PP Escutcheons, illustrated herewith, are Escutcheon', Fl or 1122 Data: the only recessed escutcheon to be used with MOdel Fl Res sprinklers. UsO of any other recessed escutcheon will void all approvals and warranties. For intalling Model Fl Res Pen- dent sprinklers use Only the Model D sprinkler Wrench: for installing Models Fl Res Recessed Pondent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench: for iii stalling Model i Res Recessed HSW sprnklers use only the Model GFH2 Sprinkler Wrenbh. Use of wrsnches other than those specified may damage these sprinklers. frsta!l 51 Res 44 with a ceiling to dot IeOtbr distance of 4" - 12". Flow arrow on deflector must point aay frOñi near Wall and 'Top' mark ing mu-it face ceiling, 1 Type Adjuatmerit aki Inch (mmi) Inch (mm) Pace *f fitting th ceiling Deflector Distafte below bottom of beam - 190' MIN ecessed= 11i(41.3) /a(9.5) . 1/(44.4) Max Recessed a Ia (222) I 1/s (286) '12 Min, Recessed m 1/s (41.5) (9.5) 13/-(44.4) Max. Aeôeediis(28.6). ... .Is(22.2 1 1/4 (3iiL Noto: E5cuthøns Fl or r2 may bG used with Model P1 Not 4 65 & ?6 Pe6ëss5d POñdeht Sprinkler Model Fl Res 30 ReCessed Pendent I P2 Model Fl Res 30 49 58 & 16 Pendønt /F1 I. .. F1escutcho, 3/4" (1 adjustment .• 2 1/4 ICLE Oi4. i (52,nthJ 1.5116" DIA. TURN COLLAR UNTIL r-T (. - _.iI 1 x ij'r kDuct ir 7IEHT .40.4/NET SPRIA,KLER WRENCH aQSS. " r /1 . PACE or PYrNIC to r CEILING OMfENSlON -. 3/8-1 1/8' (Fl ES070NECN) 0 ADJUSTMENT 7 $ (J2rr'sj 2r P DA Fig. 1 Fig. 2 Technical Data: F1 Res 30 Pendent and Recessed Pendent (SIN R3511) Thread I Nominal Orifice Inch (mm) Max. PreSsure _pjbar} Sprinkler TemD. Retina Max. Ambient Temp. Length Inch (mmJ _.!C V" (8.2) 175(12) -176-, ff7_9 ibO For Max. Coverao area Ft x Ft (m m) Max. , Ft (m) Ordinary Temp Rating Jjbmso 8C) intermediate Temp. Rating (175'F#Y°c) Top of Deflector to Ceiling lnóh (mm) Minimum Spacing YL Flow GPMmin PresSUre Flow Pressure JJbr1. 12 x 12 (3,6 x 5,6) 12(36) 8(503) . 70(048) 8(303) ., 70(048) . . Smooth C. eOiMgs 11,4 tO 4 (31 7 to 102) uting F2 eutche6r1. Beamed Ceilings per NFPA 130 `13R 8(24) or 13 ingtdiled in beams Vto 13 (31 ito 44 41 using 2 escutcheci 14 ( 14(4,3 X.4,3) 14(43) - 10 (378) .-. 11(0 78) 10 (87:8) 11(0,76) 18 X 16 (4,D X 49) 1 (49) . 15 (49) 18 8 (1 3) 15(49) 18 8 (13) For Ceiliria Woes refer to NFPA 13.13H or 13D 2. Technical Data: Fl Res 49 Pendent and Recessed Pendent (SIN R3516) Thread Nominal Orifice Max. Sprinkler Max. Actual V Sprinkler Size Inch 'mm' Pressure Temp. Rating Ambient Temp. K Length OF °C OF °C psi (bar) Factor Inch (mm) 1/2" NPT (R½) ,lb / 5(12) 155 175 68 79 100 150 38 66 4.9(70.6) 2.25(57) T Ordinary Temp. Rating Intermediate Temp. Rating .. Top of Deflector Minimum Max. Coverage area Max. Spacing (lS5°FiR°C) (175°F179°C) to Ceiling Spacing Flow Pressure Flow Pressure FIx Ft (mx m) Ft (m) Inch (mm) Ft (m) GPM (L/min) GPM (Llmin) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) 13 (49) 7,0(0,48) VV V Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. . V V V V . 14x 14(4,3x4,3) V 14(4,3) 1$(49) 7.0(0,48) 13 (49) 7.0 (0,48) 1to4(25.4t0 102) using Fl V................• V V escutcheon. 16 x 16(4,9 x 4,9) 16(4.9) 13(49) 7.0 (0,48) 13 (49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) V . 18x 18(5,5x5,5) 18(5,5) 17(64,3) 12(0,83) 17(64.3) 12(0,83) beams 1¼to134 (31.7t0 V V V V V V V VV VVVVVV 44.4) using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7(1,14) 20(75,7) 16,7 (1.14) to 13%(25.4t044.4) using Fl V V - escutcheon For Ceiling types refer to NFPA 13, 13R or 13D V V V V Ordinary Temp Rating IidermedPatiremp Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (1550Fd89C) (1759F/7900)V_VVV . to Ceiling V Flow V Pressure Flow Pressure Fix Ft(mxm) Ft (m) Inch mm Ft (m) GPM (1/mm) PSI (bar) GPM (lhtiin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 15(57) 9.4(0,65) 15(57) 9.4(0,65) Smooth Ceilings 4 to 8(100 to 203) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6 (0,73) 16(60,5) 10.6 (Q,73) 4t08 (100 to 203) using Fl escutcheon. V V V V V 16 x 16(4,9 x 4,9) 16(4.9) 17(64,3) 12.0(0,83) 17(64,3) 12.0(0,83) Beamed Ceilings per NFPA 13D, 13R or 13 installed In beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 41/4 t08(108to203) using F2 4t08(100to203) V V V V V VVV 20 x 20 (6,1 x 6,1) 20 (6,1) 22(83,2) 20,2(1,4) 22 (83.2) escutcheon, rE~l using Fl escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread Nominal Orifice Max. Sprinkler Max. V Actual V V Sprinkler Size Inch (mm) Pressure Temp, Rang Ambient Temp. K Factor Length WNPT V ½'(13) 175(12)175 155 68 79 V 100 1 150 38 1 66 5.8(83.5) 2.25(57) Ordinary Temp Rating Intermediate Temp. Rating Top of Deflector V V MInimum Max. Coverage area Max. Spacing (155DF,8oC) (l75°F/79C) to Ceiling Slwlnn Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch 'mm Ft (m) GPM(LMiln) PSI (bar) GPM(L/min) PSI (bar) ' -, 12 x 12 (3,6 x 3,6) 12(3.6) 16(61) 7.6 (0,53) 16 (61) V 7,6(0,53) V Smooth Ceilings 11/4 to 4(31,7 to 102) using F2 escutcheon, V V V VV V V V V 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) 7.6 (0,53) 16 (61) 7.6 (0,53) 1 t 4(25.4 to 102) using Fl escutcheon, V V V 16x 16(4,9x49) 16(4,9) 16(61) V 7.6 (0,53) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 13D, ISR or 13 installed in beams 8(2,4) V ... V 18 x 18(5,5 x 5,5) 18(5.5) 19(72) 10.8 (0,75) 19 (72) 10.8(0,75) 11/4 to $ (31.7 to 44.4) using 1,2 escutcheon, 1 t i% (25.4 to V VVV VVV V V VV V VVV V VV V V 20x20(6,1 x6,1) 20(6,1) 22(83,3) 14.4(1,0) 22(83,3) 14,4(1,0) 44,4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 130 3. 't66hn166 bata P1 Res t6 Pendeht and Rceesd P ndent (801111611811 thread NOnnaiorifioe Max. PAN NO fix, .. a/41, NPT ii . 155 08 _izJL._L.J_5QLLJ 100 36 ...L 2.25 Ordinary Temp. 1ndIeTern Ailing Mimm Max Coverage area Max1Spacing (1SBFi86C)_ J7fl#*C) - Top Dflectorto Ceiling n' Spgclhg FlOW Pressure FiowGPM Pressure FtxFt(mxm) Ft 01 Inth(mrn) pin bar 12x 12(3,6X36) 12(36) . (7b,5) T6 (0,53) 21(79,5) 76(0,53) Smooth Ceilings 44to8(108 to23) using F2escutcheon. 14x 14(4,3x43) 14(4,3) 21(70M) 7.6(0,53) 21(79,5) .6(0,8) 4to8(100to203)u9k1g1 cUtchoft 16 x 16(49k 4,9) 16(4,9) 21 (79,5) 76(053) 21 (79,5) 76 (0,53) l8bamod CGilir9s pr NFPA 1,13or13 installed in hems 41,i to 8 (1 08 to 2o) u I2 esouttheori. 4 O 8 (100 6 (2,4) IS X 1 8 5) 1 6 (55) . 21 (795) 7.0 (0,5) 21 (*5) 76 (O53) 20x2b(,I xGI) 2(6,i) 23(1i) (0,03) t2O)ugF1 theon For COMM tvbes iefer to NPPA 13. 1311 or lab Model 0166 20 664k 16 Pen done Maiiel Fl ha 30, 4, 68 & 16 _.___._SJ •1 'h *No *Noi Iltsd for 60069idh rèi0tarice 2 eli6" b/A. HitC IN ctLiNr3 t5&Ymmj up I ' 1/2 ktDUCEP CEIUNO 5: MAN. rA Oi rn f' or cEitip A ciWEi AolugrM? . j.... b 135FG04E (• ") - .S...- rig. 8 Note:. The. Fl Res .76 will Liao a. 1" xW reducer. COP Cover Plate Data UAO Cover Adjustment OB 60 Height . . . fl1j, Deflector Distance below bottOm Inch (mm) Inch (mm) of beam Inch (mm -. /ie(7.9) . . .J/4.(t 9)_ ½.(13)-1(25.4Y. rr, sourieon Fig.4 FP Escutcheon Data PP Position "A" Deflector Distance below bottom Inch () of beSm . Inch (mm) Max.Recestad /i(11) 1/2(12.7) Mm. Recessed I - (24) Note: Sihklers showh in rig. 3 and Pig. 4 are not tuitable for installation in ceilings which have positive pressure in the space thôve. 4. Technical Data: Fl Res 30 CCP Pendent and Recessed Pendent/FP (SIN R351 1) - Thread Nominal I Max. CCP Assembly I Max. Sprinkler Size Orifice I Pressure Temp. Rating I Ambient Temp. I Factor Length I OF I °C OF Inch (mm) psi (bar) I Inch (mm) W' NPT (R112) 21/3" (8.2) 175 (12) 135 - 57 100 38 3.0 (43,2) 2.25(57)' Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating i!E/rC) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Flow Pressure GPFifljL/min) PSI (bar) t m 12 X 12 (3,6 X 3,6) 12(3,6) 8(30,3) 7.0(0.48) Smooth Ceilings ½ to 1(13 to 25.4) using CCP. ½ to 1(13 to 25.4) using FP escutcheon. 8eamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2.4) 14x 14 (4,3 x 4.3) 14 (4,3) 11(37.8) 13,4(0,92) Ytoi(13to254) using Fl? escutcheon, For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) Thread Nominal Orifice CCP Pressur eAssembly Ambient Sprinkler Size Inch psi Temp. Factor Length mm, (bar) Rating Inch (mm) OF °C OF °C 1h.NPT /&(11) 175(12) 135 57 100 38 4.9(70.6) 2.25(57) Max. Coverage Ordinary Temp. Rating - Minimum Max. Spacing (155°F,8°C) Top of Deflector to Ceiling area Ft x Ft (m x. m) Ft (m) Inch (mm) Spacing Ft (m) Flow Pressure GPM (Llmin) PSI (bar) 12 x 12(3,6 x 3,6) 12($,6) 13(49) 7.0(0,48) .Smooth Ceilings He to 1(13 to 25.4) using x x 14 14(4,3 4,3) 14(4,3) 13(49) 7.0(0,48) cCP. 1 to 1(13 to 25.4) using FP escutcheon. -. 16 x 16 (4,9 x 4,9) 16(4,9) 14 (53) 8.2 (0,56) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using 8(2.4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68,1) 13.5 (0,93) CCP. ½ to 1(13 to 25.4) using FP escutcheon. 20x20(6,1 x6,1) 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Thread a Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. Rating Ambient Temp. Factor a Length °C OF Inch (mm) psi (bar) Inch (mm) 1/2" NPT 1h" (13)_ — 175 (12) 135 57 100 38 5.8(83.5) 2.25(57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing -_(1559FI80C) Top of Deflector to Ceiling Spacing Ft x Ft (m x m) Ft (m) Flow Pressure Inch (mm) m GPM (1/mm) PSI (bar) 12x 12(3,6x3,6) 12(3,6) 16(61) 7.6(0,53) Smooth Ceilings 1 to 1(13 to 25.4) using CCP. ½ to 1(13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16(61) 7.6 (0,53) 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 131), 13R or 13 installed in beams ½t0 1 1 to 25.4) using CCP, 8(24) 18 x 18 (5,5 x 5,5) 18(5,5) 19(72) 10.8 (0,75) ½ to 1(13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13F or 13D 5. teChfllóI Data F1A 76 CC, P Pafldeht and Red Pø1dsnt/VP (SIN 1116) Th d Nàm Máx.TCAmbi Sprinkler 1 ørthee reSth 1.Jm Length I oF J Inch (mm) psi (bar) ] Ihch (mm)J .. ---. - t. ~ ~ ------- j00 J7.6(iO9)La25(5flj ax Overage Max,dmun beds , DefIt6r t CSilltlg FtxFt1rnmt R(m) ' Flew esetr spading ' lnch(mffl) 12xi(35x3,6) 12(38) p1(795) 76(053) Smooth CiIins . tO 1(13 to 264) using CCP 1/, to 1 (IS to 26-A) using PP 6scutchWhl 14 x 14 (4,3 x4,3) 14 (4,3) 21(795) 1:6 (0.3) 16 16 (4,9 x 4.9) 16(4,9) 1 (795) 7;8(0;6) 8eed Colllhgs per NFA 13b, 13R or 13 intI!ed 1.6 booms V O1(13to25.4)uñgCCP. 6(24) 8x 18(5,5x 5,5) 18(5,5) 2 (83,3) 8.4 (8) i to 1 (13 to 254) using P eutCheor 20x20(6,1x6,1) .01) .. 126 .0 i-or L;eulng types WOW NEPA 13, 13R Or 131) PACC Or. FIMM6 TO WALL bIMENSION 2 I/4' Hbtt. OFA. i' x ,'r 7 I/4MIM I (,i.8frflj h7J~) I OIMNSi0N I 75/16" DIA..tjjR (49.2h) 71rr 2 27/32" b flCi-iT AGAINST SPRINKLER MUNCH 6055. Ir P2 outhon, 1/ irnrn) ddjustme6t TcchhIcei Data FiReS 44 HSW & 1118WIP2 (SIN 1) Thread Nominal MaX . Sprinkler Ambient K Sprinkler 01fke P,esSure Thmp Rating Tern Foot Length —' nch(mm) psi (bar) tis JYL 1AI, NP LL. 1V5 J[IJL .100 .4(63) L. Escutcheon, F21 Data: F— Face of Pitting TY136 Adjuatment to wall Inch (rfim) /2( ) (4.1-17.4) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°Fi) Intermediate Temp. Rating (175F/79°C) T r Deflecto t Ceiling Inch mm PSI (bar) Minimum Spacing Ft m Flow GP Mn Pressure SJar Flow GPM(n,) Pressure 12 X 12 (3,6 X 3.6) 12(3.6) 12 (45.4) 7:5 (0,52) 12 (45,4) 7,5 (0.52) 4 to 6(100 to 152): ½ (13) recessed using F2 escutcheon 8(2,4) 14 x 14 (4,3 x 43)_- 14(4,3) 14(53,0) 10.2 (0,71) 14(53,0) 10.2 (0,71) 16 x 16(4,9 x 4,9) 16(4,9) 16(60,6) 13.3 (0,92) 16(60,6) 13.3 (0,92) 16x 18(4,9x5.5) - 16(4,9) 18(68,1) 16.8(1,16) 18(68,1) 16.8(1,16) 18x 18(5,5x5,5) 18(5,5) 19(72,0) 18.7(1,29) 19(72,0) 18.7(1,29) 16x20(4,9x6,1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) 12 x 12(3,6 x 3.6) 12(3,6) 14 (53,0) 10.2 (0,71) 14(53,0) 10.2 (0,71) . to 12 (152 to 305): ½ (13) recessed using FZ escutcheon 14 x 14 (4,3 x 43) 14(4,3) 16 (60,6) 13.3 (0,92) 16(6016) 13.3 (0,92) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,4) 15.0 (1,04) 17(64,4) 15.0(1,04) 16x 18(4,9x5,5) 16(4.9) 20(75.7) 20.7(1,43) 20(75,7) 20.7(l.43) 16 x 20 (4,9 x 6, 1) 16(4,9) 23(87,1) 27.4(1,89) 23(871)_- 27.4(1,89) For Ceiling types refer to NFPA 13, 13R or 13D rechnical Data F1 Res 58 HSW& HSW/F2 (SIN'R3533) Escutcheon, F2, Data: Nominal ci Max. Sprinkler Face of Fitting Ambient Length Adjustment Thread Orifice Pressure Temp. Rating Type Factor Inch Inch (mm) in to wall ch (mm) _______ (mm) OF 175 °C °F °C (mm) (R½) 1/2 (13) 175 (12) 68 60 5879 150 (835) 245(62) F2 1/2 (13) Ordinary Temp. Rating intermediate Temp. Rating Max. Coverage area Max. Spacing (155°F168°C) ,(175°F/79°C) To of Deflector to p Minimum Ft x Ft (m x m) Ft (m) Ceiling Spacing Flow Pressure Flow Pressure GPM (L/min) PSI (bar) GPM (Llmin) PSI (bar)' inch 'mn' ' Ft m 12 x 12 (3,6 x 3,6) 12(3,6) 16(60,6) - 7:6 (0.53) 16(60,6) 7.6(0,53) 4t06(100t0 152): 14 x 14 (4,3 x 4,3) 14(4.3) 18(68,2) 9.7(0.69) 18(68,2) 9.7 (0,69) -'---- . -' 16x 16(4,9x4,9) 16(4,9) 21(79,5) 13,2(0,91) 21(79,5) 13,2(0,91) 1/2(13) recessed using F2 esoutcheon 16x18(4.9x5,5) 16(4,9) 25(94,7) 18,6(1,28) 25(94,7) 18.6(1,28) 8(2,4) 16 x 20 (4,9 x 6, 1) . 16(4,9) - 29(109,8) 25,0(1,73) 29(109,8) 25,0(t73) 12x 12(3,6x3,6) 12(3,6) 22 (83,3) 14.4 (1,Q) 22(83,3) 14.4 (1,0) 6t0 12(152to305): (13) recessed 14x 14(4,3x4,3) 14(4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4 1,0) --. 16 x 16(4,9 x 4,9) 16(4,9) 26(98,4) 20.1(1,39) 26(98,4) 20.1 (1,39) using F2 escutcheon 16x 18(4,9x5,5) 16(4,9) 31(117,4) 28.6"(1,97) 31(117,4) 28.6 (1,97) For Ceiling types refer to NFPA 13, 13R or 13D 7. * Not listed for corrosion resitanoe 4, to 126 tEoJMjO I ..f1_11J I/4 t.si,mJ MthIM,,rn Fa a YUR N PP I WHY 2818, 3/1 1_ 71 11 fliLL F.6 Thchnlctil bAtai 01Rea 44 SW (SIN, R98211 Th d Nominal Orlfk* Mex. Présstire AmbientK Sprinkler Length size Inch (mm) Inch (mm) ar)0 — em0 1W NPT _______ alai. (10) 17(12) j5 100 38 4(83) 2.45(62) _ • Max Coverage area Max. Spacing _!L_ V OP o or o Minimum Flow Pressure FtxPt(mxm) Ft(m) Inth flflj) 12x 12(3,6x3,6) 12(3,6) 13(4 12) 8.7(080) ____ 4to6(100tO152) i)rossed 1in2sduthaoh 14x14(4,3x4,3) 14(4,3) 14(53,0) 16(01) 16x 16(4,9x4;9) 18(4,) 11(64,3) .-..-•-.-----.-• 1.O(1,1) 16X 18(4,9X&5) 164,9) 19(71,8) l(113) - 16 x 20 (4,9 x 6,1) • ..--.-,..----- 16(4,9) 23(87;1) 27.4(1,89) 8(24) 12 x 12 (3,6 x 36) 12(3,6) 14 (52,9) 102(0,71) 6to12(152t0305); 14x14(4,3x4,3) 14(4,3) 15(56,1) •• 11.1(0181) 16x 16(4,9x4,9) 16(4,9) 18(68,1) 16.8(1,16) 16.8(1,16) usIng F2 escutcheon using 20.7(143) 16x 18(4,9x&5) 16(4,9) 20(75.6) For Ceiling types refer to NFPA 1, 13F or 130 MrdI KRR HSWY 11-ink Technical Data: Fl Res 58 HSWX (SIN RA3533) Thread - Nominal Max. Sprinkler Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Rating P. Factor Length Identification Inch (mm) psi (bar) inch (mm) Number (SIN) °F -OF OC Bulb - '/2 NPT (R/2) 1/? (13) 175 (12) 155 175 68 I 79 100 150 I 38 I 66 5,8 (83.5) 2,45 (62) RA3533 Max. Coverage area Ft x Ft (m x m) Ft (m) Max. Spacing(155'f48°C) Ordinary Temp. Rating Intermediate Temp. Rating (175°Ffl9°C) Topof Deflector to Cellin Inch mm Minimum S acm ng Ft m Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8(2.4) 20x20(6,1x6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 16 x 22 (4,9 x 6,7) 16(4,9) 33 (125) 32.4(2,23) 33 (125) 32.4 (2,23) 16 x 24(4,9 x 7,3) 16(4,9) 38(144) 42.9 (2,96) 38(144) - 42.9 (2.96) 14 x 26 (4,3 x 7,9) 14(4,3) 42 (160) 52.4(3.75) 42 (160)__- 52.4 (3.75) 18x20(5.5x6,1) 18(5,5) 35(133) 36.4(2,5) 35(133) 36.4(2,5) 6t0 12 (152 to 305): 1/a (13)recessed using F2 escutcheon 16x22(4.9x6,7) 16(4,9) 38(144) -- 42.9(2,96) 38(144) 4Z9 (2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42 (160) -' ---- 52,4 (3,6) -.--- 42 (160) 52-40.6) 14 x 26 (43 x 7,9) 14(4,3) 46 (174) [:6T9(4,34) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13. 13R or 1$D MadI Fl Res SA HSWX 1RuIh H~—l 11/16"M/N. CEILING TO [3.2mm] DEFLECTOR DIMENSION -4 -- -- 2 27/32" 014. [72.2mm] FACE OF FITTING TO WALL DIMENSION 2 1/4" HOLE 0/A. [57.2mm] 1" X 1/2" REDUCER "\o!! I 1 15/16" (49.2mm] TURN COLLAR UNTIL — TIGHT AGAINST SPRINKLER WRENCH BOSS. 73517006 AWUSTMEN .EL.FES 58 HSWX Fig. 7 Technical Data: KRe958 HSWX (RA363) -- --- - - S Thread Nómlflal Max. Ambient K Sprinkler Sprinkler Sprinkler size Orifice Pressure -aC.- Factor Length ldenticatkrn Inch (mm) Inth (mm) Number (SIN) l(barFC Link W(13) i7 job ] 38 8 (83) J 45 (62) RA3593 Max Coverage area Max Spacing OrdInary Temp. . (165°F/t4"C) Rating . T DeIICO to ° 0 r Minimum Pt iiPt(mxm) Pt (m) Inch' soddiho Flow .M(Urn Pressure SIiba 18x20 (5,5x6,1) 18(5,5) 29(109) 25(1,72) 4to6(100 to 152): ... 20 20x20(6,1x6,1) 20(6,1) 30(i14) 25(19) . 16 x 22 (49 X 7) 16(4,9) 33(125) :4 (2;23) (13) rSoesGed ucin F2 ôuchóh 8(24) 1x24(49x73) 16(4) 9(l44) 42(298) l4X26(43x1,) 14(4,3) 42(10) 524(3'75 18 x 20 5x61j i8(5) -. 85 I 6t0 12(152to305): ½ (13) ecesed 16x22 (4,9B7) i6(4,) 38(144) • 429 (256) 16 21 (4,9 x 73) 16(4,0) 42 (160) 62A (36) using F2 esoutheon i426(4,3x7) ..4....... 14(4,3) ...:. .-.-. -.'• 46(174) 62.9(4.34) Por Ceiling typei refer to NFPA 13, 13R or 130 Malfltennce - MOdel Fl Res 3d, 4 Fl Has 5, rl Aa6 16 and N Pls 44 Sprinklard should be inspected And the sØnkler sys tern maintained in accordance With NEPA 25 ig, 13 and lA. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluid Remove dust by un a soft brush at gentle vacuuming. RemoVe any sprinkler which has been painted (Other than factOry applied) or damaged In any way. A stock of spare srinklere should be maintaired to d1low quick replacement of damaged or operated sriñklers. Prior to instIlation, tprihklerg §hould rerhaim in the original cartons and 0do-k6glho until used: This will minimize the potential fat damage to srihkler that could cusé improper operation or nOnbperatioh, Model Fl Res 30 49 & 58 Pendent Sprinkler Specifications Sprinklers Shall be [cULus Listed] [NeW York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpmlft2 over the listed coverage area, Listed flows as specified by the manufacturer's technical data sheets are to be USed. Residential sprinklers shall be lhtalied in conformance With the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for FiRes 49. Sprinkler frame and deflector shall be of brOnze frame constructiOn having a 1/" NPT thread. Wa- ter ceal assembly shall cOhst Of a .Teflon* coated Bel- leville sprind washer With top-loaded extruded or cold head Cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (E80C)] (115°F (7°C)], Sprinklers shall have a nominal K-factor Of 3.0, 4.9 and 5.8. 3tandard finiéh: [Bronzel [Chrome- plated] (White Polyester] [Special finish— specify]. Resi- dential pendant sprinklers shall be Reliable Model Pi Res O, 49 & 58, SIN P361 1, R3516 & R351 (bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/F1 Model Fl 900 3O 40 & 58 Recessed Pendent/ FZ Modol Fl Res 30,49 & 58 Recessed Pendent/ FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (25-93-E)] low flow residential recessed pen- dent sprinklers engineeted to provide a minimum design density of 0.06 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used, Residential sprinklers shall be installed in: conformance with the manufacturer's in- stallation guidelines and the applicable Installation stan- dard. Defleotor-to-ceiling distanCe listing shall be 1" to 8" maximum, only for FiRes 49. Sprinkler frame and deflec- tor shall be of hrohze frame construction having a ½' NPT thread, Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded *DuPont legistered Trademark 10. or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with 1/2' adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model Fl Res 30, 49 & 58 Recessed Pendent lFl] [Model Fl Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30, 49 & 58 Recessed Pendent/FP] SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpmlft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NFl thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (571C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color.- specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be Used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPI thread. Water seal assembly shall consist of a Teflon* coated Bel *DuPont Registered Trademark 11. leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed, The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res $8, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R351, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135), Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated) [White Polyester) [Spe- cial finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). Model Fl Res 16 Recessed Pendent/FI, Modes Fl Abs 76 Recessed Pendent/P2, MOdl 01 Res 76 Recessed PendentlPP Spihklers §hall be [cULus Listed] low flow reIdeñtiaI recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gprn/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data theets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's Installation guidelines and the applicable installation standard. Sprinkler frame and deflector shell be of bronze frame coh8trudtion havg a 3/44' NPt thread, Water seal assembly shall consist of a Teflon* coated eel- levifle sØring waSher with machined or cold head cup with 3 mn glass bulb containing no plastic parts, and hav- ing a temperature rating Of [155014 (686C)] [1751,P (796C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. ReOesed SscutChSon assembly shall be a steel, twOpiece escutcheon [with W adjust- ment (Model F2)] (with A" adjustment (Mdél Fl)] [of puhoñ àhd thread off design With W' adjustment (MOde el FP)]. Standard finish shall be (brass][bright chrome] (white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model Fl Rés 76 Recessed PsndehUF] [Model 1 N6 76 Recesed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendeflt (Concealed) Sprinklers shall be [cULus Listed] low flow residential ooncealed sprinklers eneineerod to provide a minimum design density of 0.05 pm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac turers installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having al/4" NPI thread. Wa tar Seal assembly shall consist of & Teflon* coated Bel- leville spring washer with machined or cold head cup with mm glass bulb containing no plstiO parts, arid having a temperature rating bf 15F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flee. Method Of attaching the cover plate to the sprinkler cup shall be C push-oh and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating Shall be 135°F (571C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color epecify] ]. Concealed pendant sprinklers shall be Reliable Model Fl Res 76 CCP, SIN A7618 (Bulletin 135). Finishes SthndardFinishes Sprlhkler Pscutcheons Cover Plates l3rone Bras., White Painted Chrome Pted Bight Chrome Plated Chrome White and Black White Painted PIyeter°) Cotd Special Application Finishes - Sprinkler Fl, F2, PP ebtroless Nlkel PTPE(Thflon 2) Escutcheons Electroless Nickel PTFE (ieflon) Bright Brase Bright Brass Olack Plated Black Plated 5160 Paint Black Paint Off WNW Off White ChrmeuIL hrome bull " Other finiShes and colors are available on special order. Consult factory for details. OULus listed Corrosion e5istarit NOteS Paint or any other coatkig applied Over the factory fihish will void all approvals and warranties. Ordering information Specify: 1 Sprinkler Model 2, sprinkler Type 3. Temperature Rating 4 Sprinkler Finish 5. EQUtchdorh Finish Coer Platte Firh *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, rectory Mutual Research Corporation, or other similar oreaniaons and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for Over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throUghout the United States, Canada arid foreign countries. Mantiftur&r1 liv Reliable Automatic Sprinkler Co., Inc. (800) 41-l588 Sates Offices (500) e48-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablasprirtklercom Internet Address ®Recycled Paper Revision lines indicate updated or new data, ES. printed in U.S.A. 06/1 5 P/N 9995970235 Sidewall Recessed Horizontal Sidewall XLH Concealed Pendent XLH Pendent Bulletin 014 Rev. N H I..... Model F1 FR Series e I a Quick Response Glass Bulb Sprinklers Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Lilifi Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Product Description Canada (cULus). Reliable Model F1FR series sprinklers FM Approvals (FM) are quick-response automatic sprin- I Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element. I VdS SchadenverhUtung GmbH (VdS) Model F1FR series sprinklers are Stan- NSF Certified to NSF/ANSi Standard 61 Annex G dard Spray sprinklers, with the excep- I (NSF) tion of the Model Fl FR56 Conventional )LH Recessed EC Certificate: 0786-CPD-40239 (RA1414), 0786- sprinkler which is an Old-style/Conven- Pendent FP CPD-40251 (RA1425), 0786CPD-40252 (RA1475) tional sprinkler. (EC) The Model F1FR Series automatic sprinklers utilize a 3.0 UL Listing Category mm frangible glass bulb. These sprinklers have demonstrat- Sprinklers, Automatic & Open (VNIV) ed response times in laboratory tests which are five to ten Quick Response Sprinkler times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal tertperatures, the glass bulb contalm th6 fluid in both the liquid and vapor phases. The vapor phase ban be seen as a shiali bubbled As heat Is apled, the liquid expands, fording the bubble smaller and smaller ae the liq uid OrddsUro inOreases COntInued heating forces the liquid to push out against the bulb; causing the glass to shatter, bpeniho the waterway and allowing the deflector tO distrib- ute the discharging water. Model Fl FR series sprinklers provide a wide range of op - tons WherS quickresponse; glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal side- Wall; and vertical sidewall deflectors K4actors Of 2,8 (40 metric), 4.0 (? metric), 4 (60 metric), and 5.8 (80 Metric) Flush, recesSed, and concealed installations See the Design and Installation information table in. this Bulletin for information on the approvals and aailabili' Of, seóifio Model Fl PR series sprinkler 6011figUrations, Model El FR Pecessed Pendent and ReceSsed HOrion tal Sidewall sprinklers are required to bO used with Reliable Model Fl, P2, Or PP recessed escutcheons. See the Re- cessed Escutcheon Data table in thiS aulletin for listing and approval inorm&tion with each specific MOdel Fl PR 5e'ies prihkler. Model El and P2 recessed escutcheons, ShoWn in Fig I dhd S, àe a frItibh fit aseembly allowing for /4noh (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model PP recessed eSOutcheons, shown in Pig. 2, provide a 1/2-,inch (1.1mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model El FRS6LL Conàealed Pendet sprinklers are required to be used with Model COP cover plate A standard profile Model CCP cov- er plate i available that prOvides u to 1/2-inch (1217mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8Mrnm) of cover plate adjustment. See the Design and In- Ctallatioñ Information and Listed and Approved Temperature Ratings tables in this Bulletin for 'further information on ap- proved cover plate options AppliCatIon Model PiFk Series sprinklers are intended for use in accordance with NFPA 13, FM Property Lots Prevention Data Sheets, and the requirements of the Authority Haw. ing Jurisdietih. Care must be exorcised that the k4act0r, temperature rating, deflector style, and 6pfirikler type are in accordance With the requiremeht of the' alioable design and installation standards. In addition, Model l ER 9'niO5 sprinklers must be used in acbrdance with their listins and approvals, as well aS the information provided ih thiS gUlldtih. Installation Glass bulb sprihklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation Reliable sprinkler installation wrench- es are designed to install sprinklers With bulb protectors in place, Remove the bulb protector at the time when the sprin- kler systern is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not uSe toblS to remove bulb protectors. 2. Model FiFR Series'sprinklers must be installed with the Reliable sprinkler installation wrench identified in the De&gn and Installation Information table ih this Bulletin. Any other wrench May dfflage the sprinkler. A ICak tight sprinkler jOint can be obtained With a torque of 8 to 18 1b4t (11 to 24 N-th). Do not tlhten sfrmnklers over the rnaimum recommended installation torque. lExceedind the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR SerieS Reáessed sprinklers are to be installed as shown in Fig. 1, Pig. 2, or Fig, 3, as applicable to the spe- cific model being in8talled. The Recessed Escutcheon Data table in the bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinkler Model Fl FR torles Concealed Pendent sprinklers are to be installed as shown in Pig. 4 or Fig. 5, as applicable to the selected cover plate. Model Fl FR56 Concealed Pendant and Model Fl FR56LL Concealed Pendant sprinklers have a factory-installed Model CCP cup. A protective cap Is in- stalled at the fctcry that should remain on the sp?inklCr until the sprinkler IS installed and 5huld then be reinstalled on the Sprinkler until the cover plate is intalled. The concealed sprinkler assemblies are completed by the installatiOn of a Model COP pUshonfthread-off cover plate assembly. The cover plate and Sprinkler cup assemblies are joined uSIng a cover plate Skirt with flexible tabs for threaded engage- ment. A OholcO of two Model CCP cOver plate assemblies provides either 1/2'1nch (1mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model FiPA Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model Fl PR Series Concealed Pendent sprinklers require a 2-5/8-Inch (67mm) diameter hole to he out in the ceiling. The Model AOl wrench is uSed to engage the sprinkler wrenohing surfaceS and to Intail the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the Sprinkler/cup assembly care should be taken to prevent damage to the sprinkler. Do not wrench any other Oan of the sprinkler/cup assembly. Installation Is com- pleted by remving the protective cap from the sprinkler and pushing the cover plate Onto the cup, Pinl edjustmont is made by hand furring the Oovsr plate until the Skirt flange makes full dontactwh the coiling Cover plate removal requires turning the cover plate in the counter clockwise direction After installation, ihspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with spscifiO sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR6 Concealed Pendent and Model Fl FR56LL Concealed Pendant sprinklers Or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not Specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NFl standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation M Model Nominal Orifice Diameter Information Nominal Deflector! Orientation Nominal Sprinkler Height installation Wrench SIN and Listings A Approvals Approval Notes US Metric Inches mm Inches mm Pendent 2.25 1 57 0 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA14111 cULus 2 F1FR28 2.8 40 3/8 10 Upright 2.25 57 D RA14211 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendant 2.25 57 D RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendant 2,25 57 D RAI410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1FRXLH Pendent 2.25 57 D RA1413 cULus - 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 with Pintle) - - - Upright 2.25 57 - RA1423 cULus 12 Pendent 2.25 57 D RA1414 QULus, FM, LPCB, VdS, EC, 123,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCVdS,EC 123,4 Concealed Pendent 225 1 57 RC1 IRA1414 cULusVdSEC 56 F1FR56 56 80 1/2 15 Upright 2.25 57 D RA1425 cULus, FM, LPCB,VdS,C 1,2,3,4 (Pendant or Upright) 2.25 57 D RA1475 LPCB, VdS, EC 4 Pendent 2.25 57 D RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF F1FR56LL 5.6 80 1/2 15 Concealed Pendent 2.25 57 RCI RA1414 cULus, NSF 6 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 F1FR56 5,6 80 1/2 15 Recessed Horizontal Sidewall 263 67 GFR2 RA1435 cULus, FM 8 F1FR56 56 I 80 1/2 15 Vertical Sidewall (P ) 225 57 D RA1485 Lus, FM, cULPCB 1,2,3,9 1 cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating, cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1FR56 Concealed Pendant sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8,0 mm) of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only In Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient ,.. Temp..... Intermediate temp ClasslflãStiOn 150°F (65°C) Max Ambient . ..remp ..•. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) ..Temp Rgtiflg. 155°F (68°C) Temp. Rating. 115-P(796C) Temp. Rating 200°F (93°C) Temp Rating, 286°F (1 41 °C) Temp. I Rating O?aflge Bulb Red Bulb Yellow Bulb Green Bulb BluC Bulb Fl PR28 .Fecessed Pendent ..... .... ii ....cULus .. . .-... O.LLus ...,, . . Fl FR40 . ..VdS .Recessed Pendent .. .... -... . I . . •.. ,ôULu .. F1FR42 Recessed Pendent -. ... ... ,....... . I ..--. .. .. ..0 right ....cULus . Recessed Perident . ... -- . .. ....oULu -.t....- ... cus..N$FII . . - N de .., . UpiqL .... .,. cULs ... ...... ..,., ...... . .. .,... CULiS Perdent ......... Q.gssedP.efldntL cLUS FM. LPc.B VdEC... F1 FASO neaIed Prsjir, .c!JLus. .. ... ...cULs ..-.. `Coiiventioral Ed ... . .. .. .cULus,.NG Fl FR56LL - RecøsedPendent .. . ... ., .. .. . ..LUS,. NSF Cønaled Pedent*. cULus, NSF . ... ... ....... . ... . . .... .. Fl FF456 .io.rJpol Jjewa!L... recessed HorOntaI . ... UL Fl FF456 .. .._dentrVp.rigb.. VertaI Sidwall (Pen- . ULus FM PC ... Model P1 Pi56 Cocealed Pehdert and Fl FR56LL Conosaled Pendent sprinklers ffiLlSt be Used with Reliable Model CCF cover plates. For Ordinary Temperature Clasiuiction sprinklers use a 136F (571,C) temperature rated cover plate. For hiterrtiediate Temperature CIasiflation sptinklers use a 165F (40) temperature rated cover plate. Recessed Escutcheon Data Model .. / Orientation ..adjustment . Usted end Approved Rcesaad Eecutcheone SIN . Model Ii (Hg. 1 & 3) 8f4-lnh (19mm) Model F2 (Fig 1 & 3) 1/24n0h (1247mm) stme nt. ..adiustent, Model FP (Fig. 2) 1/2-Inch (12Jmm) F1FR28 Recessed Pendent .. cULuS . R1411 ... . ecssed Pendert - ys VdS FIFR42 Recessed Perdent . .bULu cULus . cULus . RA 1413 .lR42Ij ssed Fendgnt ., ULUSI NSF . . CULU, NSF . cULus, NSF . .cULus RA1410 F1PR42XLH Recessed Pendrit. . cULus.ôULus .cULus ... cULus . RA1413 Fl FF456 Recessed Pendent cULus, LPCB, VdSI EC cULus,FM,LPCB, EC cULus, VdS, EC RA1414 rF1,FASOLL Recessed_Perident cULu _NSF ULus_NSF RA1415 FRS6,.r. . .cULt&s,FM_._...cI4Lus -. - RA1435 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl çSCuTCHEoN AT MAXIMUM RECESS 1 "(25.4mm.7 AT MINIMUM RECESS x 3/879.5mm] f P2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'r1gmmj AT MINIMUM RECESS =r 3/879.5mm] F) ESCUTCHEON AT MAXIMUM RECESS 7/8722.2mm] (3.2mm] I / AT MINIMUM RECESS 1-.518'T41.3-m] ( F ESCUTCHEON AT MAXIMUM RECESS = 1-1/8728.6mm] AT MINIMUM RECESS = 1-5/8741.3mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS----\ Fl EScUTcHEOj_ 3/4 "[19mm] ADJUSTMENT 1/2 "[lZ 7mm] ADJUSTMENT f 2 1/4" HOLE 0/A. [57.2mm] I I 1/16' 0/A (49.2mm) I- i t1.-------- - TI / /O I'. L 2 27/32" 014. (72.2mm) 1 Model F1FR56, F1FR56LL, FIFR42I F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon I- I i"x 1/2k REDUCER 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" 014. [58. 7mm] 1 CUP CEILING FACE OF FITTING osvu TO FAf,g,7LING DIM - - AT MAXIMUM RECESS = 1- 1/2738mm] - - AT MINIMUM RECESS 172.4mmJ OM RECESS j AT Dc;'Er ME __________ ] AT = = 9/167l43mm] 31/4D14. [82.6mm] mg.;-, Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, FIFRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5' PAcoEflrnNC lti PACE OE CEILINO bIMENSIÔN tLESCUtCHEON. AY MAXiMUM RECESS = ?T2.4mrj AT MINIMUM REceSS AT MAXIMUM RECESS 3mthj AT MINIMUM RESS 3/ Tg5'" V -.---.. Af JAVithiii l" 1b "Pi 6 7 ft IWtflfSUVt!dtYt I * At MINIMUM CS i/i 4tMj 1T2 ESCi.JTbHEON AT MAXiMUM RECESS 7 -5/8'4 1.3mm3 AT MINIMUM RECESS a-1/16'r52.4mthj S _...L (1) 1? [101. 6mrn-3O4.thn] DIA. CEILING TO I bEPLEtTOR TURN COLLAR UN77L ' TICHT AGAINST SPRINKLER WRENCH ROSS. H 3/4Yi9minJ ADJUSTMENT 1/'Ii Pmrj AIJIJrMENT (1) EM APP/OiEi e& 4" ' (lb i.MM i.4MMJ OIL/NC ft WL&60 WITH P2 ON/i'. Mode' F1FR56 Receed Horizontal Sidwall sprinkler with Model F'l or P2 éutchëo X 1/2" RECUC/N&. tE OR aBOW .--, 2 5//s" CUP CEILING 1/2" MAX; COVER ADJUSTM,'NT —.2 5/8' CIA, HOLE IN CEILING 1 1/2" I,IAX. PACE or FlrrlfvG O P'A(;11 E C.J\ 'Y' CIMENS/ON COVER PL4TE - ASS(MI3L)1 SPRINKLER .cOJCALED...J /2DJ.U.S.TMNt Fig.4 Model 1 F56iF1 P56LL Concealed Pendent aptinkleir with aandard depth 1/2-inch (121rn) adjustment - Model CCP ôover plate 1.1 / x 1/2" REDUCING TEE OR ELBOW 2 5/8" 0/A. 2 3/16 VIA - ______ HOLE IN CEILING C tip 1 1/2" MAX. FACE OF FITTING TO FA ON CE CEILING f 51,16" MAX. J14 COVER PLATE ASSEMBLY _ 3 5/16" VIA. .SPRINKLER CONCEALED. 5/16" ADJU5TENT Fig. 5- Model Fl FR561F1 FR56LL Concealed Pendant sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (') Standard Finishes Sprinkler Escutcheon Cover pIate11 Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated V Coated "" I White Painted Special Aj,plication_Finishes Sprinkler Escutcheon cover piate 1 Electroless Nickel PTFE'7) Electroless Nickel Bright Brass PTFE _13 right Brass(') Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint'2116' Black Paint Off White Off White(266) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. " cULus Listed only. 200°F (93°C) maximum. ' cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW). RA1485(VSW). RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. " FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1 435 and RA1425 in standard black or white. ' LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant 7. Material Data Frame: V V PZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: ODA Alloy 360 or 544 Cup: VVV V CDA Alloy 651 or 693 Washer; V V Nickel Alloy 440 or 360, coated with PIFE Adhesive Tape Bulb; Glass Ordering Information Specify: Sprinkler Model: [Fl FR28][F1 FR4O][F1 FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] (Recessed Pendentj[Uprightj[Conventional](Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (57°C)][155°F (680C)][ 175°F (79°C)][200°F (93°C)][286°F (141°C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] 9, Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][ 165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Rellable...For Complete Protection-,-- Reliable offers a wide selectiöh of sprinkler components Pollcwing are some of the many precisth.made Reliable products that guard life and property from fire around the clock, Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Conàealed autorn atic sprinklers Adjustable automatic sprinkrs [)y automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm Valves Retarding oh ambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches- * Water flow detectors Deluge valves- -6 Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons ähd guards Inspectors test connections Sight drains ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges identification signs Fire department connection The euipment presented in this bulletin Is to be bistafed in at'tordance with the latest published Standards of the National Fire Protection Association rectory Mutuel Research Cororatidn, oi, other similar organizations Cñd also with the provisions of governmental codes or ordinances whenever applicable, Prbducit manufactured ehd dietilbuted by Rdiable have been Prottidlihd lftófld pr0erty fO? Over 90 yeere,and are installed And serviced by the most highly qualified end reputable sprinkler contractors located throughout the United St6te6i Canada and foreign coun1rios Manufactured by RelIable Automatic Sprnklèr Coil ine Reycied ® (800) 411688 Stiles Offices Pnpor ~800) 846,6651 8this F61X Rp offices iRevision linesindicate updated 01 low thi IM11111 W--- wWw reliablespritikler corn Internet Address EG Prin ed ir U ' .' 2/1' P/N 99997O300