1640 BASSWOOD AVE; ; FPR2022-0029
PERMIT REPORT it (e of Carlsbad Print Date: 07/21/2023 Job Address: 1640 BASSWOOD AVE, CARLSBAD, CA 92008-1947 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2050602700 Track #: Valuation: $970,444.07 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2022-0029 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 10/06/2022 Issued: 11/14/2022 DEV2021-0192 Finaled Close Out: 07/21/2023 Final Inspection: INSPECTOR: Robinson, Jarrod Cheung, Nathaniel Project Title: HARRIS RESIDENCE Description: HARRIS -NEW 13D SPRINKLER SYSTEM FOR NEW SFR (80 HEADS) FPContractor: RIOS FIRE PROTECTION INC P0 BOX 1546 EL CAJON, CA 92022-1546 (619) 212-0956 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $148.00 FIRE NFPA 13D Single Family System (Plan Review) $292.00 Total Fees: $440.00 Total Payments To Date: $440.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 I Inspections: 442-339-2660 1 www.carlsbadca.gov . HYDRAULIC CALCULATIONS FOR HARRIS RESIDENCE FILE NUMBER: 01-243 DATE: 9/21//22 OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/400 sq.ft. AREA OF APPLICATION: BED 3 WIC COVERAGE OF SPRINKLER: 20'X 20" NUMBER OF SPRINKLERS: I SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 20.0 gpm TOTAL WATER REQUIRED (including hose): 25.0 gpm FLOW AND PRESSURE (@BOR): 20.0 gpm @ 32.6 psi SPRINKLER ORIFICE SIZE: • 1/2" inch NAME OF CONTRACTOR: RIOS FIRE PROTECTION INC. DESIGNER: ROBERTO RIOS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT. CONTRACTOR CERTIFICATION NUMBER: C16-1025305 WATER DEPARTMENT: CARLSBAD WATER DIST. CONTACT: JENNIFER MAEL DATE: • 8/25/22 STATIC: 73 psi SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 9/22/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\HARRIS RESIDENCE.SDF JOB TITLE: HARRIS RESIDENCE WATER SUPPLY ANALYSIS Static.: 63.00 psi Resid: 46.00 psi Flow: 2250.0 gpm 70.0 LEGEND 1 60.0 G A U G 5020 E P 40.0 R E S 30.0 S U R E 20.0 1 jAvailable pressure 63.00 psi @ 25.0 gpm 2 lRequired pressure 50.31 psi @ 25.0 gpm Source Supply Curve System Demand Curve p 10.0 5 I 0.0 -14.7 6009001200 1500 1800 2100 2400 2700 3000 FLOW (GPM) )te: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/22/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\HARRIS RESIDENCE.SDF JOB TITLE: HARRIS RESIDENCE NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 63.0 46.0 2250.0 63.0 25.0 50.3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 25.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 20.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 13 25.0 K= 4.90 16.7 20.0 12 25.0 - - - - 19.0. - - - 11 25.0 - - - - 19.0 - - - 10 25.0 - - - - 20.0 9 25.0 - - - - 22.1 - - - 8 15.0 - - - - 26.1 - - - 7 15.0 - - - - 27.3 - - - 6 15.0 - - - .29.1 - - - 5 9.0 HOSE STREAM 32.6 5.0 4 5.0 - - - - 37.8 - - - 3 3.0 - - - - 40.5 - - - 2 3.0 - - - - 44.5 - - - SOURCE 0.0 SOURCE 50.3 25.0 NOTES SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/22/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\HARRIS RESIDENCE.SDF JOB TITLE: HARRIS RESIDENCE NFPA5 PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 7.0 20.00 150 5.9 SOURCE 0.0 50.3 25.0 3 1.000 7.00 1.3 2 3.0 44.5 25.0 0.995 27.00 0.169 4.6 Pipe: 2 0.0 Fixed Pressure Loss Device 2 3.0 44.5 25.0 4 4.0 psi, 25.0 gpm 3 3.0 40.5 25.0 Pipe: 3 0.0 0.0 5.0 50.00 150 2.7 3 3.0 40.5 25.0 5 1.250 5.00 0.9 4 5.0 37.8 25.0 1.394 55.00 0.033 1.8 Pipe: 4 H.S. 5.0 Disch 19.0 5.00 150 5..2 4 5.0 37.8 20.0 6 1.000 19.00 1.7 5 9.0 32.6 25.0 1.025 24.00 0.146 3.5 Pipe: 5 0.0 0.0 7.0 6.00 150 3.5 5 9.0 32.6 20.0 .7 1.000 7.00 2.6 6 15.0 29.1 20.0 1.101 13.00 0.068 0.9 Pipe: 6 0.0 10.2 9 13.0 13.00 150 1.8 6 15.0 29.1 9.8 8 1.000 13.00 -0.0 7 15.0 27.3 20.0 1.101 26.00 0.068 1.8 Pipe: 7 0.0 0.0 20.0 49.00 150 1.2 7 15.0 27.3 9.8 10 1.000 20.00 -0.0 8 15.0 26.1 9.8 1.101 69.00 0.018 1.2 Pipe: 8 0.0 20.0 11 35.0 62.00. 150 6:1 8 15.0 26.1 -10.2 1.000 35.00 4.3 10 25.0 20.0 9.8 1.101 97.00 0.018 1.8 Pipe: 9 0.0 0.0 29.0 15.00 150 5.2 7 15.0 27.3 10.2 10 1.000 29.00 4.3 9 25.0 22.1 10.2 1.101 44.00 0.020 0.9 Pipe: 10 0.0 20.0 11 29.0 79.00 150 2.1 9 25.0 22.1 -9.8 1.000 29.00 -0.0 10 25.0 20.0 10.2 1.101 108.00 0.020 2.1 Pipe: 11 0.0 0.0 10.0 4.00 150 1.0 10 25.0 20.0 20.0 13 1.000 10.00 -0.0 11 25.0 19.0 20.0 1.101 14.00 0.068 1.0 Pipe: 12 0.0 0.0 15.0 13.00 150 0.0 12 25.0 19.0 0.0 1.000 15.00 -0.0 11 25.0 19.0 0.0 1.101 28.00 0.000 0.0 Pipe: 13 4.90 20.0 Disch 17.0 18.00 150 2.4 11 25.0 19.0 0.0 1.000 17.00 -0.0 13 25.0 16.7 20.0 1.101 35.00 0.068 2.4 lZm SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: /22/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\HARRIS RESIDENCE.SDF JOB TITLE: HARRIS RESIDENCE NOTES (HASS) Calculations were performed by the HASS 2021 D computer program in accordance with NFPA13 (2020) under license no. 64916306 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.007 gpm and a maximum imbalance at any node of 0.086 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.3 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SOURCE under full flow conditions is 62.99 psi with a flow of 28.64 gpm. PIPE FITTINGS TABLE User Pipe Table Name: CPVC PAGE: A MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R C L B D N E45 TEE TRUN COUPLN L90 BRANCH -------------------------------------------------------- G F 1.101 1.00 5.00 1.00 2.00 7.00 4.00 0.00 0.00 0.00 0.00 PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee F F45Ell 0.995 1.55 3.87 1.55 3.87 4.64 0.77 7.73 1.55 3.87 0.77 1.025 1.79 4.47 1.79 4.47 5.6 0.89 8.93 1.79 4.47 0.89 1.394 3.15 6.30 2.10 7.35 6.30 1.05 10.50 10.50 6.30 1.58 HYDRAULIC CALCULATIONS FOR HARRIS RESIDENCE FILE NUMBER: 01-243 DATE: 9/21//22 OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/256 sq.ft. AREA OF APPLICATION: BED 3 WIC COVERAGE OF SPRINKLER: 16'X 16" NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 26.2 gpm TOTAL WATER REQUIRED (including hose): 31.2 gpm FLOW AND PRESSURE (@ BOR): 26.1 gpm @ 25.9 psi SPRINKLER ORIFICE SIZE: %" inch NAME OF CONTRACTOR: RIOS FIRE PROTECTION INC. DESIGNER: ROBERTO RIOS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT. CONTRACTOR CERTIFICATION NUMBER: C16-1025305 WATER DEPARTMENT: CARLSBAD WATER DEPT. CONTACT: JENNIFER MAEL DATE: 8/25/22 STATIC: 73 psi SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page DATE: 9/22/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\HARRIS RESIDENCE.SDF JOB TITLE: HARRIS RESIDENCE WATER SUPPLY ANALYSIS Static: 63.00 psi Resid: 46.00 psi Flow: 2250.0 gpm 70.0 1 60.0 G A U G 50.0 E 2 P 40.0 R E 30.0 S U R E 20.0 LEGEND 1 jAvailable pressure 62.99 psi @ 31.2 gpm 2 lRequired pressure 48.61 psi @ 31.2 gpm Source Supply Curve System Demand Curve p 10.0 S i 0.0 -14.7 600900 12 00 1500 1800 2100 2400 2700 3000 FLOW (GPM) )te: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 9/22/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\HARRIS RESIDENCE.SDF JOB TITLE: HARRIS RESIDENCE NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 63.0 46.0 2250.0 63.0 31.2 48.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 13 25.0 K= 4.90 7.0 13.0 12 25.0 K= 4.90 7.2 13.2 11 25.0 - - - - 8.1 10 25.0 - - - - 9.7 - - - 9 25.0 - - - - 13.2 - - - 8 15.0 - - - - 16.9 - - - 7 15.0 - - - - 18.9 - - - 6 15.0 - - - - 21.8 5 9.0 HOSE STREAM 25.9 5.0 4 5.0 - - - - 32.9 - - - 3 3.0 - - - - 36.5 - - - 2 3.0 - - - - 40.5 SOURCE 0.0 SOURCE 48.6 31.2 NOTES Pipe Tag K-fac Add Fl Add Fl To Fit: L C Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. Pipe: 1 Source 0.0 7.0 20.00 150 SOURCE 0.0 48.6 31.2 3 1.000 7.00 2 3.0 40.5 31.2 0.995 27.00 0.254 Pipe: 2 0.0 Fixed Pressure Loss Device 2 3.0 40.5 31.2 4 4.0 psi, 31.2 gpm 3 3.0 36.5 31.2 (Pt) (Pe) NC I (Pf) 8.2 1.3 6.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/22/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\HARRIS RESIDENCE.SDF JOB.TITLE: HARRIS RESIDENCE NFPA5 PIPE DATA Pipe: 3 0.0 0.0 5.0 50.00 150 3.6 3 3.0 36.5 31.2 5 1.250 5.00 0.9 4 5.0 32.9 31.2 1.394 55.00 0.049 2.7 Pipe: 4 H.S. 5.0 Disch 19.0 5.00 150 7.0 4 5.0 32.9 26.2 6 1.000 19.00 1.7 5 9.0 25.9 31.2 1.025 24.00 0.219 5.3 Pipe: 5 0.0 0.0 7.0 6.00 150 4.1 5 9.0 25.9 26.2 7 1.000 7.00 2.6 6 15.0 21.8 26.2 1.101 13.00 0.112 1.5 Pipe: 6 0.0 13.4 9 13.0 13.00 150 2.9 6 15.0 21.8 12.8 8 1.000 13.00 -0.0 7 15.0 18.9 26.2 1.101 26.00 0.112 2.9 Pipe: 7 0.0 0.0 20.0 49.00 150 2.0 7 15.0 18.9 12.8 10 1.000 20.00 -0.0 8 15.0 16.9 12.8 1.101 69.00 0.030 2.0 Pipe: 8 0.0 26.2 11 35.0 62.00 150 7.2 8 15.0 16.9 -13.4 1.000 35.00 4.3 10 25.0 9.7 12.8 1.101 97.00 0.030 2.9 Pipe: 9 0.0 0.0 29.0 15.00 150 5.8 7 15.0 18.9 13.4 10 1.000 29.00 4.3 9 25.0 13.2 13.4 1.101 44.00 0.032 1.4 Pipe: 10 0.0 26.2 11 29.0 79.00 150 3.5 9 25.0 13.2 -12.8 1.000 29.00 -0.0 10 25.0 9.7 13.4 1.101 108.00 0.032 3.5 Pipe: 11 0.0 13.0 13 10.0 4.00 150 1.6 10 25.0 9.7 13.2 12 1.000 10.00 -0.0 11 25.0 8.1 26.2 1.101 14.00 0.112 1.6 Pipe: 12 4.90 13.2 Disch 15.0 13.00 150 0.9 11 25.0 8.1 0.0 1.000 15.00 -0.0 12 25.0 7.2 13.2 1.101 28.00 0.031 0.9 Pipe: 13 4.90 13.0 Disch .17.0 18.00 150 1.1 11 25.0 8.1 0.0 1.000 17.00 -0.0 13 25.0 7.0 13.0 1.101 35.00 0.031 1.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 9/22/2022 C:\USERS\CANDI\ONEDRIVE\DESKTOP\HARRIS RESIDENCE.SDF JOB TITLE: HARRIS RESIDENCE NOTES (HASS) Calculations were performed by the HASS 2021 D computer program in accordance with NFPA13 (2020) under license no. 64916306 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 65 9-97 60 The system has been calculated to provide an average imbalance at each node of 0.016 gpm and a maximum imbalance at any node of 0.186 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe l.- Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SOURCE under full flow conditions is 62.99 psi with a flow of 37.01 gpm. PIPE FITTINGS TABLE User Pipe Table Name: CPVC PAGE: A MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R C L B D N E45 TEE TRUN COUPLN L90 BRANCH -------------------------------------------------------- G F 1.101 1.00 5.00 1.00 2.00 7.00 4.00 0.00 0.00 0.00 0.00 PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv -------------------------------------------------------- GatVlv AlmChk DPVlv NPTee F45Ell 0.995 1.55 3.87 1.55 3.87 4.64 0.77 7.73 1.55 3.87 0.77 1.025 1.79 4.47 1.79 4.47 5.36 0.89 8.93 1.79 4.47 0.89 1.394 3.15 6.30 2.10 7.35 6.30 1.05 10.50 10.50 6.30 1.58 tqC17 Worldwide www.tyco-fire.com Contacts Rapid Response Series LFII Residential 49 K-factor Concealed Pendent Sprinklers, Flat Plate Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Se- ries LFII Residential 4.9 K-factor Con- cealed Pendent Sprinklers (TY3596) are decOrative, fast response, fus- ible solder sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 130 wet and dry pipe residential sprin- kler systems for residential occu- pancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has been designed with heat sensitivity and wa- ter distribution characteristics proven to help in the control of residential fires and to improve the chance for occu- pants to escape or be evacuated. The Series LFII Residential Concealed Pendent Sprinklers (TY3596) are shipped with a Disposable Protective Cap. The Protective Cap is temporar- ily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Protective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers (TY3596) need not be increased over the number of de- sign sprinklers (hydraulic design area) as specified for wet pipe sprinkler sys- tems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers of- fer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hy- draulic design area) for systems de- signed to NFPA 13,13D, or 13R. Non- water filled pipe will permit options for areas sensitive to freezing. L!LIJtDI The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) described herein must be installed and maintained in Compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having ju- risdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number TY3596 Page 1 of 6 APRIL 2013 TFP442 BODY (1/2" NPT) CAP SADDLE - SUPPORT CUP WITH ROLL FORMED THREADS GUIDE PIN V GUIDE PIN HOUSING DEFLECTOR THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SOLDER TAB ..fl r I n_I fln_ Uflhu1Ifl ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) 7 SOLDER LINK ELEMENT I : DEFLECTOR (OPERATED POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY RETAINER WITH THREAD 11 - DIMPLES COMPRESSION SCREW SPRINKLER WRENCHING AREA SEALING ASSEMBLY - COVER PLATE JETION SPRING LEVER TFP442 Page 2 of 6 WRENCH RECESS i PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH 2-1/2 DIA. (63,5 mm) 1/2' NPT... - 1/2 (12,7 mm) FACE OF THREADED SPRINKLER ADJUSTMENT FITTING v 1-7/8"±1/4" 1- (47,6 mm I 1/8 GAP I ±6,4 mm) I (3,2 mm) SPRINKLER- SUPPORT CLIP =-s ASSEMBI OPERATE SPRINKLE COVER PLATE RETAINE 7\J 7/8" (22,2 r 1-1/8 (28,6 DISPOSABLE I- .T- I COVER- SPRINKLER- I J MOUNTING RETAINER SUPPORT CUP 3/16" J SURFACE ASSEMBLY ASSEMBLY (4,8 mm) -. 3:!/1! DIA. _______ ______ ______ DEFLECTOR IN (51,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Data Approvals: UL and C-UL Listed. NYC Approved under MEA 44-03-E-2 NSF Certified to NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are only listed with the Se- ries LFII Concealed Cover Plates hav- ing a factory applied finish. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K=4.9 GPM/p5i112 (70,6 LPM/bar1"2) Temperature Rating: 160°F 71°C) Sprinkler with 139°F 59°C) Cover Plate Vertical Adjustment: 1/2 inch (12,7 mm) Finishes: Refer to Ordering Procedure section Physical Characteristics: Body.....................Brass Cap.....................Bronze Saddle ...................Brass Sealing Assembly.. - Beryllium Nickel w/ TEFLON Soldered Link Halves ........Nickel Lever....................Bronze Compression Screw.........Brass Deflector..........Copper or Brass Guide Pin Housing .........Bronze Guide Pins .........Stainless Steel or Bronze Support Cup ...............Steel Cover Plate ..............Copper Retainer ..................Brass Cover Plate Ejection Spring ........ ........Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. At this point the De- flector supported by the Arms drops down to its operated position. The fus- ible link of the Sprinkler Assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction.. System Types Per the UL Listing; wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 130 and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Ta- bles A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum re- quired discharge from each of the total number of "design sprinklers" as specified in NFPA 130 or NFPA 13R. The number of "design sprinklers" specified in NFPA 130 and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ ft' over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13 for wet pipe sys- tems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers (TY3596) in dry pipe sprinkler systems, the time for water delivery must not ex- ceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 130, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described with- in the Technical Data Sheet TFP490. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFII must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion in a fire situation. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure(b) Maximum Coverage Maxi Spacing mum Ordinary Temp. Rating Area (° Ft. 160°F (71°C) Minimum Ft. x Ft. (m) Deflector to Installation Spacing (m x m) Flow Pressure Ceiling Type Ft. GPM PSI (m) (L/min) (bar) 12x12 12 13 7.0 Smooth (3,7x3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 13 7.0 inches (4,3x4,3) (4,3) (49,2) (0,48) Beamed Ceilings per 8 16x16 16 13 7.0 (4,9x4,9) (4,9) (49,2) (0,48) NFPA 130 or or 13. Installed in Concealed 13R, (2,4) 18x18 18 17. 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8to1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1) (75,7) (1,15) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flowand Residual Pressure Maximum Coverage Maximum Spacing acing Ordinary Temp. Rating Ft. 160°F (71°C) Minimum Ft. x Ft. (m) Deflector to Installation Spacing (mx m) Flow Pressure Ceiling Type Ft. GPM PSI (m) (Llmin) (bar) 12 X 12 12 13 7.0 Smooth (3,7x3,7) (3,7) (49,2) (0,48) Ceilings 7/8tol-1/8 14x14 14 14 8.2 inches (4,3x4,3) (4,3) (53,0) . (0,57) Beamed Ceilings per NFPA 13D or Concealed 8 16x16 16 15 9.4 (4,9x4,9) (4,9) (56,8) (0,65) 13R, or 13. Installed in (2,4) 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0,93) 7/8to1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (C) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 5 of 6 Installation The TYCO RAPID RESPONSE Serie LFII Residential Concealed Pendent Sprinklers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible Link Assembly). A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Cover Plate/Retainer Assembly by under-or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be in- stalled in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup- port Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 inch ratchet-drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceil- ing installation and/or during applica- tion of the finish coating of the ceil- ing. It may also be used to locate the center of the clearance hole by gen- tly pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service". Step 5. After the ceiling has been completed with the 2-1/2 inch (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the De- flector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to modi- fy or repair a damaged sprinkler. Step 6. Screw on the Cover Plate As- sembly until its flange comes in con- tact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceil- ing panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Se- ries LFII Residential Concealed Pen- dent Sprinklers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may de- lay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper op- eration of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help as- sure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be re- placed, if necessary, by factory paint- ed units. Non-factory applied paint may adversely delay or prevent sprin- kler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age -before, during, and after installa- tion. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. The owner must assure that the sprin- klers are not used for hanging any ob- jects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP442 Page 6 of 6 Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability. Sprinkler Assembly: Series LFII (1Y3596), K=4.9, Resi- dential Concealed Pendent Sprin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assembly: Cover Plate Assembly having a (spec- ify) finish for the Series LFll (TY3596), K=4.9, Residential Concealed Pendent Sprinkler, P/N (specify) Ivory (RAL1015) ...........P/N 56-202-0-135 Beige (RAL1001)...........P/N 56-202-2-135 Pure White (b) (RAL9010) ... PIN 56-202-3-135 Signal White (a) (RAL9003) .. P/N 56-202-4-135 Grey White (RAL9002) ......P/N 56-202-5-135 Brown (RAL8028) .......... P/N 56-202-6-135 Black (RAL9005) ..........P/N 56-202-7-135 Brushed Brass ............P/N 56-202-8-135 Brushed chrome ..........P/N 56-202-9-135 Custom Paint .............P/N 56-202-X-135 Previously known as Bright White. Eastern Hemisphere sales only. Note: All Custom Cover Plates are painted us- ing Sherwin Williams Interior Latex Paint. Contact TYCO Customer Service with any questions re- lated to custom orders. Sprinkler Wrench: Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright© 2012 Tyco Fire Products, LP. All rights reserved. t TEFLON is trademark of The DuPont Corporation. Worldwide tica Contacts RAPID RESPONSE Series LFII Residential Sprinklers 49 K-faótor Pendent Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are deco- rative, fast response, frangible bulb sprinklers designed for use in residen- tial occupancies such as homes, apart- ments, dormitories, and hotels. When aesthetics and optimized flow charac- teristics are the major consideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-family dwellings and mobile homes per NFPA 130 wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have, been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFll Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 130, or 13R. Non-water filled pipe will permit options for areas sensitive to freezing. NOTICE The Series LFIl Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable stan- dards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY2234 Page 1 of 6 APRIL 2013 TFP400 Technical Data Approvals UL Listed for use with wet pipe and dry pipe systems C-UL Listed for use only with wet pipe systems NSF Certified to NSF/ANSI 61 For details on these approvals, refer to the Design Criteria section. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi112 (70,6 LPM/bar1/2) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass Pure or Signal White Chrome Plated Physical Characteristics Frame ....................Brass Button ...................Copper Sealing Assembly ........Beryllium Nickel w/TEFLON Bulb ................Glass .(3 Compression Screw .........Bronze Deflector .................Bronze Ejection Spring ......Stainless Steel TFP400 Page 2 of 6 7/16 (11,1 mm) 1/211 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING • 27/8" DIA.________ 1 - Frame MAKE-IN SURFACE (73,0 mm) 2 - Button 4-Bulb 5 - Compression 2 Screw 2-1/4' 3 - Sealing Assembly 1 T ESCUTCHEON 6 - Deflector* (57,2 mm) 1-5/8" STYLE 20 (41,3 mm) I WRENCH RECESSED * Temperature rating is 6*...I I FLATS indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) - 2-7/8" DIA. (73,0 mm) I 7/16±1/8" 1/2" (12,7 mm) (11,1± 2-1/4" DIA. 1/4"(6,4mm)3,2mm) I FACE OF (57,2 mm) SPRINKLER MOUNTING FITTING PLATE T-7- p t MOUNTING 1/8" I SURFACE/ (3,2 mm) I 1-3/8' (34,9 mm) CLOSURE TY2234 1-1/8' (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER (TY2234) 0 "-" RECESS (END "A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 6 t - PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP400 Page 3 of 6 Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be acceptable to the local authority having jurisdiction, System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a func- tion of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is Jo be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of "design sprinklers" specified in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as appli- cable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be installed in accor- dance with this section: General Instructions Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprin- kler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFll Residential Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with thefollowing instructions. Step 1. Install pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFII Residential Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. Install recessed pendent sprinklers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. (Continued on Page 5) TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Max. Coverag (a Ordinary Temp. Rating 155°F (68°C) Intermediate Temp. Rating 175°F (79°C) Minimume Area Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (mx m) GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7x3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 41nches 14x14 13 7.0 13 7.0 (4,3x4,3) (49,2) (0,48) (49,2) (0,48) Beamed Recessed using Style 20 Escutcheon or 8 16 x 16 13 7.0 13 7.0 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) Ceilings per NFPA 13D or 13R non-recessed NFPA 13D, 13R, or 13 (2,4) per 18 x 18 17 12.0 17 12.0 (5,5x5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4to1-3/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) beam. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (C) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure(b, c) ______________________ Ordinary Temp. Rating 155°F (68°C) Intermediate Temp. Rating 175°F (79°C) Minimum Covera9e Area (a Ft. x Ft. Deflector to Installation Spacing Flow Pressure Flow Pressure (mx m) Ceiling Type Ft. GPM PSI GPM PSI (m) (1/mm) (bar) (L/min) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7x3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 4 inches 14 X 14 14 8.2 14 8.2 (4,3 x 4,3) (53,0) (0,57) (53,0) (0,57) Beamed Recessed using Style 20 16x16 15 9.4 15 9.4 Ceilings per Escutcheon or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) NFPA 13D or13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18x18 18 13.5 18 13.5 (5,5x5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4to1-3/4 inches below bottom of • 20 x 20 21 18.4 21 18.4 (6,1 x6,1) (79,5) (1,27) (79,5) (1,27) beam. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance withthe criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 5 of 6 Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, whichis used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; other- wise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and mainte- nance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly Specify: Series LFII (TY2234), K=4.9, Residential Pendent Sprinkler, (specify) temperature rating, (specify) finish, P/N (specify). 155F (68CC) Natural Brass ..............PIN 51-201-1-155 Pure White (RAL 9010). ....... P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4-155 Chrome Plated .............PIN 51-201-9-155 175°F (79CC) Natural Brass ..............PIN 51-201-1-175 Pure White (RAL 9010)*P/N 51-201-3-175 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated .............PIN 51-201-9-175 Eastern Hemisphere sales only. Recessed Escutcheon Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*). *Refer to Technical Data Sheet TFP77O. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TFP400 Page 6 of 6 a GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. tL,CQ Page 1 of 6 MICROFAST® QUICK' NIKJNG*l:II[u'7iw RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058. Telephone: 269-945-9501 TechnicalServices: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 () VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 WARNING: Cancer and Reproductive Harm- I www.P65Wamings.ca.gov I LPCB Approved: Certificate 096e/06 (( CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1 EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart I and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-M, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286 OF (141 °C) = G Form No. F_033314 18.10.11 Rev 18.1.P65 Replaces Form No. F_033314 Rev 18.1 (Added P65 Warning.) Page 2 of 6 PW ® MICROFAST® QUICK "4! RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 OF (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2 ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list prièe schedule or contact Viking directly. Protective Sprinkler - Wrench Flat Clip 00000 I 1 ,f Protective Sprinkler Cap : Figure 1: Standard Sprinkler Wrench 10896W1B Form No. F_033314 18.10.11 Rev 18.1.1365 Page 3 of 6 MICROFAST! QUICK I Vj w4j RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.cOm TABLE 1: VIlV:1 1 f ¶[* I." 1as 33 Smae inRlë l Li WOE oloH sincalln Ordinary 135 OF (57 °C) 100 OF (38 C) Orange Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 OF (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/ for recessed pendent sprinklers ** A 112" ratchet is requir4 (not available from Viking Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655WIB for Recessed Pendent Sprinklers Form No. F_033314 18.10.11 Rev 18.1.P65 Page 4 of 6 ° MICROFAST® QUICK "sJ IF(II1G l:II[.1u.JWA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com ij?or,ai GWa? I (J ThWg ksonse Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 _Criteria.) Part SIN K-Factor Length (Refer also to_ Design Number1 Style NPT BSP U.S. metric- Inches mm cULus4 VdS LPCB ( 8 12979 VK302 Pendent 1/2° 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, BIY DIZ, CIY DIW 19780 VK302 Pendent 1/2° -- 5.6 80.6 2-1/4 58 -- - - -- - D3 21354 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 -- - - -- - 03 NOTICE Product TIBelow ontact Local VikingZ•]iIlj 06662B VK302 Pendent 1/2° 15 mm 1 5.6 1 80.6 1 2-1/4 58 A1Z, B1Y, 02, C2X I -- -- - 18021 VK302 Pendent 1/2° 15mm 5.6 1 80.6 1 2-1/4 58 AIX, B1Y Al I AIX, B1Y I D1X, Clvi I D1W Approved Temperature Ratings Approved Finishes - Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F 1 - Brass, Chrome, White w - Recessed with the Model F-I Adjustable Escutcheon only (79 °C), 200 °F (93 °C), 286 °F (141 °C) Polyester-', Black Polyes- X - Standard surface-mounted escutcheon or the B - 135 °F (57 °C), 155°F (68 °C), 175 °F ter 6 Viking Micromatid Model E-1 Recessed Escutcheon (79 °C), and 200 °F (93 °C) 2- ENT5 Y - Standard surface-mounted escutcheon or the C - 155 °F (68 °C), 175 °F (79 °C), and 3-Chrome Viking Microfast5 Model F-1 Adjustable Escutcheon, or recessed with the Viking Micro- 200 °F (93 °C) matice Model E-1, E-2, or E-3 Recessed Escutcheon O - 155 °F (68 °C), 175 °F (79 °C), 200°F Z - Standard surface-mounted escutcheon or the (93 °C), 286 °F (141 °C) Viking Microfast® Model F-I Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. ° Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021. °MED Certified, Standard EN 12259-1, EC-0832-MED-I003. cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers: Designed for use in Light and Ordinary occupancies. ° The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 18.10.11 Rev 18.1.P65 Page 5 of 6 MICROFAST® QUICK NIKJNG4 l:II[.1•'7w RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com MinThI5IaS2lP I I Base Part Sprinkler Thread Size Nominal K-Factor I Overall Length FM Approvals3 SIN Number' Style NPT BSP U.S. metric' Inches (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 E - P roduct Below rmiuiAvailability ( 5T Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 AIZ, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 1 15 mm 5.6 • 80.6 2-1/4 1 58 AIZ, BIY Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 °C), 200 "F Viking Micromatic Model E-I Recessed (93 "C), 286 "F (141 "C) Approved Finishes Escutcheon B - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), and 1 -Brass, Chrome, White Polyester4, V - Standard surface-mounted escutcheon or the 200 "F (93 "C) and Black Polyester4 Viking Microfast Model F-I Adjustable Escutcheon, C - 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), 286 2 - ENT5 or recessed with the Viking Micromatic Model E-I "F (141 °C) or E-2 Recessed Escutcheon 0 - 155 "F (68 °C), 175 °F (79 "C), 200 "F (93 "C) Z - Standard surface-mounted escutcheon or the Viking Micro.fast Model F-i Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. FM Aooroval Reauirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 18.10.11 Rev 18.1.P65 1-1/8" (29 mm) Mm. (29 mm) 2" Min. (5i) - a - 2-1/8" (54 mm) Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Page 6of' ® MICROFAST® QUICK 'sJ IF(IF1G A A A RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 260-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 2-5/16" (59 mm) minimum 1/2" - (15 mm) 2-1/2" (64 mm) maximum NPT 2-118"ø' (54 mm) * Ji 1 •. - . + 4 1-1/2" 1(57m) 1-3/4" 2" (38 mm) (45 mm) (51 mm) Mm. Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable is exposed 1/2"(13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-1/8".. S .- (54 mm) 1-3/4" -. (45 mm) Max. Installed with a Installed with a Model Model E-I Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons Form No. F_033314 18.10.11 Rev 18.1.P65 Replaces Form No. F_033314 Rev 18.1 (Added P65 Warning.)