Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2501 EL CAMINO REAL; 210; FPC2022-0201
PERMIT REPORT (City of Carlsbad Print Date: 10/18/2023 Job Address: 2501 EL CAMINO REAL, #210, CARLSBAD, CA 92008-1215 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1563023500 Track #: Valuation: $148,856.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2022-0201 Status: Closed - Finaled Applied: 11/02/2022 Issued: Finaled Close Out: 03/08/2023 Final Inspection: INSPECTOR: Cheung, Nathaniel Project Title: Description: TASTY NOODLE HOUSE -FIRE ALARM TI (ADDRESSABLE, 15 DEVICES) Applicant: FPContractor: RALPH ZIMMER JOHNSON CONTROLS FIRE PROTECTION LP 9505 CHESAPEAKE DR P0 BOX 3042 SAN DIEGO, CA 92123-6393 BOCA RATON, FL 33431-0942 (858) 967-5208 (561) 341-7780 FEE AMOUNT FIRE TI Fire Alarm System $735.00 Total Fees: $735.00 Total Payments To Date: $735.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Johnson Controls -- -3568 Ruffin Road, South.- - Johnson - San Diego, GA 92123-2597 Controls - Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com Fire Detection and Alarm System Product Submittal Project: Tasty Noodle The Shoppes at Carlsbad 2525 El Camino Real Suite 210 Carlsbad, CA 92008 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douglas.danielscãjci.com 10/20/2022 REV.#: 0 PROJECT - - 11 -----.-. Johnson . Johnson Controls 3568Ruffln Road, South . . San Diego, CA 92123-2597 Controls - . Tele (858) 633-9100 Fax: (858) 633-9101 www.jcL corn Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 2 4098-9756 Duct Detector 3240-0026:0241 2 2098-9806 Remote Test Switch 7300-0026:0150 1 4090-9001 Supervised lAM 7300-0026:0223 1 4090-9002 Relay lAM 7300-0026:0311 2 4098-9843 PAM-SD Relay 7300-1004:0101 3 4906-9104 Strobe 7125-0026:0316 4 4906-9154 Speaker Strobe 7320-0026:0247 Business Information 10/20/2022 REV.#: 0 PROJECT LSirnpIex - - - - ..TrueAIarm® Analog Sensing- .--- - UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control I1iui* Compact air duct sensor housing with clear cover to monitor for the presence of smoke Includes factory installed TrueAlarm photoelectric, smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNetrm or MAPNET Il®, 2-wire communications' Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNet/MAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) - - 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California Slate Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Usting 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revIsion, and possible cancellation. Accepted for use— City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Ustings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Duct Sensor Housing, Front and Bottom View II C 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station lnuraiurrii Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueJarm sensors and iDNet and MAPNET II communications are protected by one or more of the following U.S. Patents: 5,155468; 5,173,683; 5,543,777; 5,400014; 5,543,777; 5,710,541; 0383,407; 0388352; 0392,573; 4,796,025. S4098-0030-5 3/2007 liiiiri siiruriiizLiI7WiaiirrdI -- - - Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. IiTiT III! I Th1IIallLlij Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. . Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control for ON, OFF, or override Duct Smoke Sensor Housing with Photoelectric Sensor* I Basic Duct Sensor Housing; operating power is supplied by Simplex fire alarm control panel models 4010, 4020, 4100, 4100U, and 4120. Also 2120 CDT if 4098-9755 [either IDNet or MAPNET II communications (no relay output) configured for MAPNET II, TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not COM requires separate 24 VDC fire alarm power and 4081-9008 compatible with 2120 CDT; end-of-line resistor harness; includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required L_Model - Description Catibdity Mounting 2098-9808 Red LED status indicator 4098-9755 Use single gang box, Test Station with keyswitch and red LED status indicator 4098-9756 3" H IC 2"W IC 2" 0 (turning switch to "TEST' initiates alarm for system testing) (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor [jiodel Description - - - Compy Location_ J Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9756 only; Locate relays within 3 ft '4I9W for additional relay information; one included with 4098-9756; connect to p (1 m) of device being wiring is 18 AWG (0.82 mm2 ) color coded wire leads controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 M, 1/2 W; (ref. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Sampling Tube Selection Chart, Ordered Separately Per Duct Width, Select One - Overall Duct Wrdth (305 mm) Tube Required 2098-9796 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23' (330 mm to 584mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2" (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2" (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2" (51 mm) longer than duct width S4098-0030-5 3/2007 NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. - C Exhaust tube access hale) onduit (by others)) [ 4098-9714 Smoke sensor, mounted it - in special interlace base (supplied) ------------ Metal plate with dual holes for 3/4" (19 mm) conduit, plug supplied for unused hole E 171 mm LED, relay control trouble ____ icator (4098-9756 only) access hole Red sensor Sampling tube LED ct Wiring terminals) Stationary baffle (built-in)Captive fastening screws (Y1 [Magnetic test ar.a) Mount as shown (preferred) or [parent cover] askated sensor aJ with electronics area located to the LEFT or UP ONLY 31 (86 mm) (21 mm) 71 Test ports (2) provided for measuring airflow and for aerosol injectior Sampling tube, ordered separately per duct width Loaskets -,supplied)] Exhaust tube auapliedfl End View with Duct and Tubes Duct housing] Round duct outlin [18" (minimum diameter) 8 Square duct outline [Exhaust tubes' :*[minimum width) J I S • S --J I Sampling tube, keyed-for proper hole align/ with holes facing into airflow (template is provided for proper tube installation) 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA72 173116" 7: - • (38 mm) ui. 1-3/16'(30 mm) - 3 S4098-0030-5 3/2007 rbiit Sensor Location Reference - Exhaust Sensor Damper OK Exhaust Fresh air .Return Air _IUPPIY r sensor here 00 not locate bank Sensor OK I Bend or other J obstruction Return 1"6 Duct 6Duct wiotils : inlet '2 i-. width minimum 1 I minimum Preferred Duct Sensor Locations: 1.- Aminimumàf six duct 'ridthsdownsfreamfrom - - bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. . General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 1000 F (0° C to 38° C) Operating Temperature Range 32° F to 1220 F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 6(° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Black base with clear cover Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 11.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 1 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum [Addressable Operation - Data Communications IDNet or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755 Control, Alarm PowerSupPly Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 3 mA @ 24 VDC Alarm Current (one relay activated) 15 mA @ 24 VDC; add 15 mA for each additional remote 4098-9843 relay Supervised Remote Relay Control Output For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kQ, 1/2 Wend-of-line resistor RO -9843 Relay Output Ratmgs, Single Form C,use with Model 4098-9756 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF @ 28 VDC & 120 VAC _2501,iA@.5. VDC . Location Distance 500 ft (152 m) maximum to relay coils; relays must be within 3 ft (1 m)of device being controlled per NFPA 72 Tyco, Simplex, the Simplex logo, TrueAlarm, IDNel, and MAPNET flare trademarks of Tyco International Services AGor its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster • Westminster, MA • 01441-0001 • USA S4098-0030-5 3/2007 !3Simplex 0 2007 1)zco Safely Products Wetimintter. All rights rezeriad All spe4ficalions and other information shown were current as ofdocument revition date and aresubject to change without notice CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING•MATERIALS LISTING PROGRAM - LISTING SERVICE: .. LISTING No. 3240-0026:0241 Page 1 of I CATEGORY: 3240 -. DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplex50 Technology Drive, Westminster, MA 01441-0001 Contact: Marty Chianzio (561) 912-6252 Fax (978) 731-8881 Email: marty.chiariziojci.com DESIGN: Models 4098-9755, *4098..9755Tsp *4098..9755np 4098-9756, *4098..9756Tsp *4098-9756UP 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed: This listing should not be used to verify 'correct - operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires . June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERJNG BUILDING MATERIALS LISTING PROGRAM - - - - LISTING SERVICE LISTING No. 7300-0026:0150 Page I of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplex50 Technology Drive, Westminster, MA 01441-0001 Contact: Marty Chianzio (561) 912-6252 Fax (978) 731-8881 Email: marty.chianzio©jci.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing -should not 'be used to verifr correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E, F.P.E. Fire Engineering Division Simplex .-- I -. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* I1iui*i IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from JAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use in indoor locations up to 158° F (70° C) such as attic spaces or similar applications For use with following Simplex control panels: Model Series 4007E5, 4008, 4010, 401OES, and 4100ES fire alarm control panels for IDNet communications Model Series 4100/4100U/4100ES, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterflow switch (alarm) on same circuit using one point Available with IDNet communications only Multi-Application Peripherals IDNet and MAPNET II Communicating Devices, Individual Addressable Modules (lAMs) '1Iif 11 . 4090-900 O9O6 IAN 0 5fl 33 DATE CODE IDO 4090-9001 Supervised lAM (shown approximately 3/4 size) 4090-9051 Supervised lAM (shown approximately 3/4 size) IIi*iulUT1N Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Multiple operation modes are available and are selectable at the control panel: Model 4090-9001 is packaged in a thermoplastic Contact closure status can be tracked housing and provides screw terminal connections and a status indicating LED. Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the Model 4090-9051 is an encapsulated package with wire 2120 CDT) leads. It does not provide a status indicating LED. UL listed to Standard 864 -. - - - - * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this docoment. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4090-0001-11 11/2014 Contact Closure. Closure of the monitored contact(s) For use with IDNet communications only, these initiates an alarm or other response as programmed at the LAMs can provide quad-state sensing of normal, open fire alarm control panel. An open in the monitored circuit circuit, short circuit, and current limited conditions. wiring will cause a trouble to be reported. (Program type is "T-sense.") With the proper end-of-line Panel Selections. Selections can be made at the control and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a . determmed and communicated by a single addressable ouit rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). lAM Product Selection ITI.I TTTT IT ...•.•.I.... Supervised lAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 I Supervised lAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window. requires 4090-9810 mounting bracket. 4090-9807 1 For surface mounted box includes mounting screws; galvanized steel 4090-9810 I Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) - 4081-9004 733-886 6.8 kfl, 1/2W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 733-896 4.7 kfl, 1/2 W 4081-9005 733-984 1.8 kn, 1/2W Use for current limited monitoring applications Specifications Electrical Power and Communications MAPNET II or IDNet, auto selected, I address per lAM Input Requirements Normally open, dry contacts 4090 9001 Wire Connections - 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9151 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from [AM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications per channel, MAPNET or 110,000 It (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 4090-9001 -4090-9051 1-9/16" W x 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) 1-9/16°Wx1-9/16"H x9/16"D(40mmx40mmx14mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 158" F (0° to 70° C); intended for indoor operation Humidity Range . Up to 93% RH at 100° F (38° C) S4090-0001-11 11/2014 Mounting Information 4090-9001 IDNet Field wiring shown supervised lAM for reference LED viewing port Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate CD © © _ Light pipe for LED viewing 4-1/4" ____________ 4-1/2" (108 mm) 'DISCONNECT PR DISCONNECT POR (114 mm) BEFORE SERVICING BEFORE SERVICING © © 2-1/2" 2-13/16" (64 mm) i4 (72 mm) 4090-9806, Trim plate for 4090-9807, Trim plate for 4090-9810 Mounting semi-flush mounted box surface mounted box bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 2 S4090-0001-11 11/2014 r[sIsISIs1.1Ur1rIiwtIUrni.iiuiiflI1 Address setting is at rear of housing 4090-9051 Encapsulated Supervised lAM 1~ Single gang electrical box 2-1I2 (64mm) minimum depth (supplied by others) Single gang blank cover plate and mounting screws (supplied by others) ni plEx Tyco Fire Protection Products. Westminster, MA • 01441-0001 • USA S4090-0001-11 11/2014 www.sirn alex-flre.com © 2014 2)co Fire Protection FvthwLt. All righL e,wL Allspeczftcaiions and other information shown were cuprentav ofdwonentrevamn date and are subject to change without notice. ®Simplex . Multi-Application Peripherals UL, ULC, CSFM Listed;. FM Approved; IDNet, Communicating Devices MEA (NYC) Acceptance* Model 4090-9002 Relay lAM I711uIt*I Individual Addressable Relay Module (Relay lAM): IDNet addressable control for use with Simplex® fire alarm control panel models 4007ES, 4008,4010, 4010ES, 4100ES, and 4100U A single addressable point provides control and status tracking of a Form "C" contact Low power latching relay design allows IDNet communications to supply both data and module power Relay is set to OFF on initial power up and upon loss of IDNet communications Compact, sealed construction: . Enclosed design minimizes dust infiltration Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 11/I (119 mm) square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 Description IDNet Relay lAMs allow fire alarm control panels to control a remotely located Form "C" contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Product Selectior Relay IAM Optional Adapter and Trim Plates ' ] 013Adapterplatetofit4 "/,a" (119 mm) square electrical box 4090-9801 I For semi-flush I I Trim Plate, galvanized mounted box I steel, with LED viewing I For surface I window; includes 4090-9802 I mounted box I mounting screws * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35.93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4090-9002 IDNet Relay lAM Package (shown approximately 1/2 size) Specifications Communications IDNet communications, I address per device Relay lAM Power Supplied by IDNet communications Contact Ratings* (not rated for incandescent switching) Type Form C, SPDT 2 A @ 24 VDC, resistive from listed Power-Limited fire alarm I A @ 24 VDC, inductive supply Nonpower-Limited 0.5 A © 120 VAC, resistive * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC networks or vanstors, depending on device type. Refer to the installation instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4 As" H x 4 %" W x I 3/i" 0 (105 mmxlO5 mmx35mm) Housing Material Black thermoplastic Mounting Plate Sheet metal, galvanized Temperature - - 32° to 120° F (0° to 49° C), -- ...... Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) Installation 574-184 Instructions 84090-0002-10 11/2014 Relay lAM Mounting Information Address setting under resealable label 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) 4090-9002 Relay lAM Doube gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © 1 Light pipe for LED viewing 4-9/16" (116 mm) flEC1P 7 (109 mm) p 4-5/16" MORr VAER [NOR SERiG BOX IZ6- © © © © —4-9/16" (116 mm) 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO. SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. .SiMpl,EX Tyco Fire Protection Products• Westminster, MA•01441-0001 • USA S4090-0002-10 11/2014 www.simplex-tire.com 0 2014 J)co Fire Protection Producte. All rights reserved All spanficasione and other info 'motion shown wee current as ofdocument revision dale and are subject to change without notice CALIFORNIA DEPARTMENT OF FORESTRY & FIRE-PROTECTION OFFICE OF THE STATE FIRE MARSHAL - - FIREENGINEERING - BUILDING MATERIALS LISTING PROGRAM• LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimpIex6 Technology Park Drive, Westford, MA 01886 Contact: Jim Goyette (978) 577-4074 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models* 4090-9001, -900ITSP, -900ITTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9I06TSP, and-910611P Class "A" ZAM Initiating Module; 4090-9101, -9I0ITSP, and -9I0ITTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: "Recert 03-29-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item liSted.This listing- should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30 2023 Authorized By: WCTOR WONG, Program Coordinator Fire Engineering Division - CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE, FIRE MARSHAL - . - - - ----------------- '-FIRE. ENGINEERING BUILDING MATERIALS LISTING. PROGRAM' •' -. LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimpIex6 Technology Park Drive, Westford, MA 01886 Contact: Jim Goyette (978) 577-4074 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *4090-9010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the, item -listed. This - listing should - not.'- be used to verify correct— operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division £LSimplEx System Accessories UL, CSFM Listed; Fire Alarm Control Relays, Track Mount and MEA (NYC) Acceptance* Encapsulated; Model 4098-9843 and 2088 Series UL listed under Standard 864 as Control Unit Accessory (UOXX) Track mount package availability: Single relay module or four relay module, with or without cover, with SPDT or DPDT contacts LED indicates relay module status Cover provide status LED viewing ports Multiple coil voltage inputs, diode polarized for DC Modules are track mounted with snap-apart feature design allowing the four relay module to be separated Single encapsulated SPOT relay package with color coded 18 AWG wire leads, available in two versions: 2088-9021 (PAM- 1)Provides diode polarized multiple input voltage ability and LED indication 4098-9843 (PAM-SD) Provides a diode polarized 24 VDC coil with in/out wiring Description These multi-purpose control relays offer SPDT or DPDT, 10 A (or 7 A) contacts in a variety of mechanical packages. Models are available for coil operation by one of four input voltages allowing a single relay to be energized from a voltage source of 18-35 VDC or VAC, 120 VAC, or 230 VAC (not available with 4098-9843). Voltage selection is made by wiring to the appropriate input terminals or wire leads. Each relay model (except model 4098-9843) contains a red LED which indicates that the relay is energized. Mounting options are varied for application flexibility. Track mounted relays may be "snapped apart" from a standard four-module assembly and used independently if desired. opecti ic.iuoris I FCK mount Nelays, see page z Tar aimensions Coil Voltage 18-35 VACNDC, 120, or 230 VAC 01 Current SPOT models = 18 mA DPDT models =40 mA Terminal Blacks Up to 14 AWG (2.08 mm2 ) Contact Ratings 10A@ 120 VAC N.O. rated 1/6 HP, N.C. rated 1/8 HP 7A @ 28 VDC and @ 230 VAC Temperature Ratings UL Listed Range 137 F to 120° F (0° C to 49° C) Humidity 85% RH Non-condensing 2088-9020, MR204/C, Four DPDT Relay Package with Enclosure (shown with cover removed) Encapsulated Relay Package (typical of 2088-9021, PAW and 4098-9843, PAM-SD) Specifications Continued Encapsulated Relays, see page 2 for dimensions Connections 18 AWG (0.82 mm2 ) color-coded Iwire leads Relay 2088-9021 Contact Ratings 10 A @ 120 VAC, resistive Coil Voltage Ratings Current 18-35 VACNDC, 120, or 240 VAC 15 mA @ 24 VACNDC, &@ 120 or230VAC Relay 4098-9843 Coil Ratings 18-32 VDC input, polarized, 15 mA @ 24 VDC Contact Ratings 7 A at 0.35 p.f @ 28 VDC & 120 VAC 250 PA@5VDC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Humidity 100% RH, condensing * Listings are under Apollo America Inc. per model numbers shown on page 2. See CSFM Listing 7300-1004:0101 for allowable values and/or conditions concerning material presented in this document. S2088-0010-10 11/2014 Relay Selection Chart -t- —[,,J~ Module a' ncel N ~r —Relay Packaging Dimensions 3 Type 2088-9007 MR-bur SPDT 3-1/4" H x 2-1/8" W x 1-1/2" 0 Track mount, without cover (83 mm x 54 mm x 38 mm) 2088-9009 MR-201/T DPDT One 2088-9008 MR-1 01/C SPDT Track mount with cover 5-1/8" H x 3-1/8" W x 2-1/2" D 2088-9010 MR-201/C DPDT (131 mm x 79 mm x 64 mm) 2088-9017 MR-1041T SPOT 3-1/4" H x 8-1/2" W x 1-1/2" D Track mount, without cover (83 mm x 216 mm x 38 mm) 2088-9019 MR-2041T DPDT Four 2088-9018 MR-104/C SPOT 5-1/8" H x 9-1/2" W x 2-1/2" 0 Track mount with cover (131 mm x 241 mm x 64 mm) 2088-9020 MR-204/C DPDT Encapsulated, multi-voltage coil, 1-1/2" H 7/8 0 2088-9021 PAM-1 color coded 18 AWG (0.82 mm ) wire '38 mm x 254 mm x 22 mm ___________ __________ leads, with coil status LED NA SPDT c40894 Encapsulated, 24 VDC coil, color coded 18AWG (0.82 mm2 ) wire leads (no 1-1/2 H 1-3/16 Wx13/16 D Track Mount Relay Wiring Reference SPOT contacts rated DPDT contacts rated 10 A @ 120 VAC, resistive 10 A @ 120 VAC, resistive ® (S\ NC C NO® \@®® o 18/24 115 230 Relay energized LEO 0 18/24 115 230 I I (18-35) VDC Coil voltage (note polarity (18-35) VAC for DC) 120 VAC 230 VAC (18-35) VDC Coil voltage (note polarity (18-35) VAC for DC) 120 VAC 230 VAC EWEN MWEE amum u•u Terminal strip connections Terminal strip connections SPOT models DPDT models TYCO, SIMPLEX and the product names listed in this material are marks and/or regis:red marks. Unauthorized use is strictly pro hibiteiL f3.SjMpjjEX Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S2088-0010-10 11/2014 www.simplex4ire.com 02014 Tyco Fire Protection Prothtctic. All rights rese,wgi All speqfications and other infonnalion shown were current as ofdocwn enS revision date and are subject to change without notice CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE: ENGINEERING ;BUILDlNG MATERIALS- LISTING- PROGRAM - LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America lnc.30 Corporate Drive, Auburn Hills, MI 48326 Contact: Dale Howells (248) 332-3900 Fax (248) 332-8807 Email: dale.howells©apollo-fire.com DESIGN: Models MR-101/C, *MR..IOIICIR *MR..Io.l..SSEIC *MR..1SSE/C/R MR-104/C, *MRI04/C/R, *MR..104..SSE/C *MR..104.SSE/CIR MR-201/C, MR-201/CrR, *MR..201..SsE/C *MR.201.SSE/CIR MR-204/C, MR204/CI*R, *MR..204..SsEIc *MR..204..ssElcIR PAM-I, PAM-2, PAM-3, PAM-4, PAM-SD, RICA, RlC-2, RIC-3, RIC-4, MR-RIC-301 /*C, *MR..RIC..301/C/R MRRIC305*/C, * MR-RIC-305/C/R, MRRtC401*IC, *MR..RIc..401/c/R MRRlC405*/C and *MR..RIC..405/C/R relay modules. *Models MR-lTM/C and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with Iistee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: I. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This - listing should not be used to verifS, correct - - operational requirements or installation criteria. Refer to Iistee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division ®Simplex.. - True4lert Multi-Candela Notification. Appliances_ UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSync Operation Compatible Ihui*i Visible only (VIO) 24 VOC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Listed to UL 1971 and ULCS526 Strobes provide synchronized flash for use with: Simplex® fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control . 4009 IDNet NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in this document. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Wall Mount Strobes Jf1. FIRE - •w Ceiling Mount Strobes isc.rintir. Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. RWMWTTITNII=~~- III Proper selection of visible notification is dependent on occupancy, location, local codes; and proper applications of. the National Fire Alarm Code (NFPA 72), ANSI All 7.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S4906-0001-5 11/2014 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. ilI Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). Product Selection Multi-Candela Visible Notification Appliances (Strobes) Model; Mounting IOusing Colór "FIRE"Lettering 4906-9101 Red White wall 4906-91 03 White - Red 4906-9102 Red White - Ceiling White - Red KIimr1yairsMa1iu7II.1'uts(* - - SmartSync two-wire control is available from:. 4006, 4007ES Hybrid, 4008,401.0, 40 rOES, 4100ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet 54905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. lescription - Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; SmartSync two-wire control compatible Wall Mount Strobe Adapters Model Description DImensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) x 1-5/8" D 4905-9940 White deep surface mounted boxes Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to -mm -mm 4-7/8" x 3-1/8" x 0.060" 0 I handy box; not needed when using 4905-992E guard (124x 79x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model -- Description - -- Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1 3/8" 2 7/1 in/out 18 AWG (0.82 mm 2) wire leads, rated for 2 A NAC, X 4905-9922 Class A requires 5 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" (102 mm) square box Replacement Covers and Guards Model Description - 4905-9992 Red cover with white 'FIRE" lettering For Wall mount strobes —4905-9993 White cover with red "FIRE" lettering .....- -- 4" x 4-1/8" x 1-1/4" 0 (102 mm x 105 mm x 32 mm) Dimensions 5-1/8" H x 5" W x 1-1 /2" D 030mm x 127 mm x 38 mm) 49059961* Wall mount I 6-1/16" H x 6-1/16" W x 3-1/8" D I Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) 4905-9926" Ceiling mount semi-flush or surface mounted boxes I 6-1/8" x 4-3/8" x 2-7/8" deep (156 mmxlii mmx73mm) * UL listed by Space Age Electronics Inc. 2 S4906-0001-5 11/2014 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note I below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8° H x 5" Wx2-3/4" 0 (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd - 30 cd 75 cd 110 cd 60 mA - 94 mA 186 mA 252 mA Moun tReference RMS Currents 18 VDC at other. voltages 24 VDC 53 mA - 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4' L x 2-5/16"W x 2-5/8" D (121 mm x 75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd - 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VOC at other voltages 24 VDC - 67 mA 111 mA 207 mA 281 mA 50 mA - 83 mA 155 mA 211 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2' (38 mm) deep, by others or fl 0 ( )i r ft BO UP I Em- amp Wiringterminals--m701201 Mounting Holes: 4" square 4) Single gang (2) Double gang (3) HL Transparent housing \\ and lens assembly - Intensity selection plug, accessible only from rear of housing; on IE factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly -EIectricaI above bottom \ H r box outline t of compatible boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0001-5 11/2014 73 nt strobe Strobe intensity viewing slot ntensity selection plug, 3ccessible only from rear of lens: ousing; factory setting is 15 cd 05-9926 wire guard :ing plate -- Ceiling Mount Strobe Installation Reference - Single gang box (Wiremold 2-1/4" (57 mm) deep, supplied by others HEndy box, 1-1/2" (38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2' (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with cliDs (ERICO No. 512 or equal) CD CD CI) b" 4905-9910 Adapter Plate, required for surface mount with handy box unless using the 4905-9926 wire guard f-I I -I Wall Mount Installation Reference; Adapter PIte, Guard, and Adapter Skirt ruj jl I iii 110101001111110101001111 4905-9931 Adapter Plate 5*1 tnI 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard - Surface mou box showr 4" (102 mm) sq O box profile, 1- (38 mm) d Optional O 4905-9961 Wire Guard Stn: Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) TYCO SIMPLEX and the product names listed in this material are marks and/or regisisred marks. Unauthorized use it strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). iin plEx Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4906-0001-5 11/2014 www.simplex-tire.com 02014 1)co Fire Protection Products. All rights reseriecL All specfications and other infoI7naiion shown were cwTentas ofdocument revision dote and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY& FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE : ENGINEERING'-BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7125-0026:0316 Page 1 of I CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: SimpIex6 Technology Park Drive, Westford, MA 01886 Contact: Jim Goyette (978) 577-4074 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and -910:3 are for wall mount. Models 4906-9102 and -9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. *Models 4906-9114, 4906-9115, 4906-9116, and 4906-9117 TrueAlert Non-Addressable, ceiling mount multi-candela notification appliances. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72. *Revision 04-24-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ki the test results and/or other data but does not make an independent verification of any claims. This listing is not SJ an endorsement or recommendàtiön of the item listed. Thid ' listing should not be used to verify correctNV -- operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division ®SimpIEx TrueAlert Multi-Candela N9tification AppHances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Speaker MEA (NYC) Acceptance* and Multi-Candela Strobe; Non-Addressable IIuit*i Speaker/visible (SN) notification appliances with multi-tapped speaker and multi-tapped high intensity xenon strobe with synchronized flash: Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important wall mount installation information on page 4) Wall mount SN features: Housings are available in red or white with clear lens with contrasting white or red "FIRE" lettering Covers are available separately to convert housing color Ceiling mount SN features: Housing is white with clear lens Red "FIRE" lettering is printed on two sides Audible notification appliance (speaker): High quality voice and tone reproduction with taps for V4,1/2 , 1, or 2W, at 25 or 70.7 VRMS Capacitor input for connection to supervised notification appliance circuits Speakers are wired separately from strobe wiring UL listed to Standard 1480 and ULCS541* Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Strobes are activated from NACs selected to provide Simplex® strobe synchronization signals or from separate strobe Synchronization Modules that are available for Class B or Class A operation Regulated circuit design ensures consistent flash output and provides controlled inrush current UL listed to Standard 1971 and ULCS526* Options for wall mounted SNs: Red or white adapters to cover surface mounted electrical boxes Red adapter for mounting to Simplex 2975-9145 boxes Red wire guard * See page 2 for additional listing details and wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7320-0026:247 for allowable values andlor conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings— MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Wall and Ceiling Mount SNs ]escrintic Multi-Candela TrueAlert SNs with speaker and synchronized strobe provide convenient installation tc standard electrical boxes with extensions. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount S/V housings are a one-piece assembly (including lens) that mounts to a 4" square electrical box with extension (see details on page 4). The cover can be iickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount S/Vs also install using 4" electrical boxes with an extension (see details on page 4). Strobe Intensity Selection During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. S4906-0003-8 5/2014 Iloilo Multiple Strobes. When multiple strobes and their Proper selection of visible notification is dependent on reflections can be seen from one location, synchronized occupancy, location, local codes, and proper applications flashes reduce the probability of photo-sensitive reactions of: the National Fire Alarm and Signaling Code as well as the annoyance and possible distraction of (NFPA 72), ANSI Al 17.1; the appropriate model random flashing. The multi-candela strobes of these SNs building code: BOCA, ICBO, or SBCCI; and the are activated by NACs that provide the Simplex application guidelines of the Americans with Disabilities synchronization format. For additional information, refer Act (ADA). to data sheet S4905-0003. dtict Sltic Wall Mount Multi-Candela SNs Model Color Lettering Listings Descriptior, Housing Dimensions with L.ensi 4906-9151 Red White Multi-tapped Speaker with Multi-Candela 7 H 5 W 2 D UL & ULC Synchronized Strobe; strobe intensity (184 mm x 127 mm 67 mm 4906-9153 White Red selectable as: 15, 30, 75, or 110 candela Ceiling Mount Multi-Candela SN LModel .,.. Hg Lng Description Dimensions Listings Color Housing= 7 1,4"(191 mm) White Red UL Multi-tapped Speaker with Multi-Candela diameter, 1/2" (13 mm) deep Synchronized Strobe; strobe intensity Strobe lens protrusion = 2 %" 4906-9157 White Red ULC selectable as: 15, 30, 75, or 110 candela (67 mm) above speaker housing Depth into box = 2 3/4"(70 mm) Wall Mount SN Adapters [ II I1i IIIml Tfl 4905-9946 Surface mount red adapter skirt Required when mounting to surface 7 Sn" H x 5 3/a" W x3 /16" 0 mounted eectrical box, 4" square, (197 mm x 137 mm x 81 mm) 4905-9947 Surface mount white adapter skirt 1 1/2 deep with 1 1/2" deep extension depth with SN = 5 Ye" (149 mm) 8.i° H 5 3/4" W x 0.060" Thick 4905-9903 Adapter Plate, red, required to mount SN on 2975-9145 2975-9145 Mounting box, red, for surface or flush mount, requires adapter plate 7 7/4 H x 5 1/e" W x 2 3/4" D 4905-9903 (this box may be available for retrofit applications) (200 mm x 130 mm x 70 mm) Wall Mount SN Replacement Covers Mod& Description Dimensions 4905-9996 Red SN cover with white "FIRE" lettering 7 1/4"H x 5"W x I 3/e" 0 4905-9997 White SN cover with red "FIRE" lettering (184 mm x 127 mm x 35 mm) Synchronized Flash Control Modules Model Description Dimensions 49059914* Synchronized Flash Module, Class B Epoxy encapsulated with in/out operation 18 AWG (0.82 mm2) wire leads, I Ye" W x 2 Lx 13A6" H 4905-9922* Synchronized Flash Module, Class A rated for 2 A NAC, requires 5 mA (35 mm x 62 mm x 20 mm) operation for power Wall Mount SN Wire Guard Model Description - - Dimensions - 4905-9998 Wire guard with. mounting plate, red, compatible with. surface, and semi-flush 8 H x 6 /i " W x 3 14fl D boxes (UL listed by Space Age Electronics Inc.) (213 mm x 154 mm x 79 mm) Ceiling Mount Tile Bridge Model Description Dimensions 2905-9946 Tile Bridge See diagram on page 4 * Refer to data sheet S4905-0003 for additional flash control module information 2 S4906-0003-8 5/2014 S/V Specifications Common Environmental 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Specifications Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm' to 3.31 mm2); two wires per terminal for in/out wiring Speaker Specifications Input Voltage I 25 or 70.7 VRMS, see Note 1 below PowerTaps I1/4,1/2,1, and 2J Frequency Response Fire Alarm General Signaling I 400 to 4000 Hz 1125 to 12 kHz Speaker Output Ratings @ 10 ft (3 m) (see Note 1 below) Wattage Tap UL Listed Models, Reverberant Chamber Test, per UL 1480 Wall Mount Models 4906-9151 and 4906-9153, Anechoic Chamber Test, per ULC-S541 Ceiling Mount Model 4906-9157, 25 VRMS Input per ULC5541 70.7 VRMS Input .lfaw 'N. ..... !..2.W.... 76 dBA 79 dBA 82 dBA 85 dBA 77 dBA 80 dBA 83 dBA 86 dBA* 81.6 dBA 84.3 dBA 87.1 dBA* 89.7 dBA* 80.9 dBA 84.1 dBA 87.3 dBA' 90.2 dBA* * NOTE: Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (per ULC-5541 . AttenuatiOn Angle Attenuation Angle Anechoic Chamber Testing) -3 dB +1- 30° off-axis -6 dB +1- 55" off-axis Strobe Specifications Rated Voltage Range Regulated 24 VDC; 16 VDC to 33 VDC, see Note 2 below Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Housing Dimensions (with lens) 7 1/4" H x 5"W). 2 %" D (184 mm x 127 mm x 67 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting 15 cd 30 cd 75cd 110 Od 60 mA - 94 mA 186 mA 252 mA Reference RMS Currents at 18 VDC other voltages 24 VDC - 53 .mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA HousingDimensions Speaker housing = 7 W (191 mm) diameter, 1A" deep (13 mm); lens protrusion above speaker housirg = 23A" (67 mm); depth into box = 2 3/4" (70 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting 15 cd _.L 30 cd 75.6d' 110 cd A. 75 mA 125 mA 233 mA 316 mA Reference RMS Currents at 18 'JOG other. voltages 24 VDC% 67 mA 11.1 mA 207 mA 281 mA SO mA - 83 mA . 155 mA 211 mA NOTES: Speakers are for connection to conventional fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. The maximum RMS strobe current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Speaker Directional Characteristics Referencd .. .. U.. •• mommummommom I•U ............... .................. ............... ................... • ............... ................... . ........i..... ommommommommorm UIUUh•••U•••••••U ............,i. •••••u•••i•vuu ii••••uu••u - . i•i••u••i••u •••uiu••u•••u•uuiu •••••••••uw.uuu u••ia••..iuu•uu•u•• U•IIU•UU!AUUU•U ....,............ ••••••••rA•u••rl ••••uiiuuu•u••••uu uu•••vsuu••i ••••uuuu•u••uuu uuu•u•iu • U••U•W4UUI•••J• U••U•ILI••••••UU•• • •••u•r.uu••••vi•• ••uu•••i•••••uuu•u • mum EMENERNME - u••uiuu..0 uu•u••••uuuu•:. • UII.NNNU.U..0 I.N.N.....IUU.NNIUN 3 S4906-0003-8 5/2014 movablecover requi IF E Ceiling Mount S/V Installation Reference and Tle Bridge Dimensions - 4" (102 mm) square, 1-1/2" (38 mm) deep box with 1-1/2° extension (by others) Wiring input terminals anc speaker tap selection are accessible from rear of speaker housing fl Strobe intensity viewing slot .. Intensity selecticn plug, accessible only from rear of lens housing; factory setting is 15 cd Wall Mount Installation Reference Mounting to 2975.9145 Box " ' Standard Electrical Box Mounting 4" (102 mM) square box, 1-1/2" 2975-9145 Box —_L j : (38 mm) deep, with a 4" square box extension, 1-1/2" deep, by others o Adapter Plate L 2 __ jS7Th(jmcJ 7 \ / .-\....................... (_ 4 F---T a (2905-99461 1/2"(l3mm) Tile Bridge 0.024" thick sheet metal, folded with 1/2" lip each side 3-3/4" (95 mm) square cutq,centedon plate 1/4" diameter (6 mm) holes, 4 places 23-11116° (602 mm) u 13-3/8"(340 mm) IMPORTANT! INSTALLATION MOUNTING HEIGHT REFERENCE 2975-9145 box oudlne'-.. ,_- 4" square box outline E1 JtJ1E4'(10 2mm) tt 82"(2.1 m)J 1-10 (38 mm) minimum NFPA 72 requires that the 78-1/2" (2 m) entire lens be not less than I minimum 80° and not greater than 96" above the finished floor. H_ Wiring input terminals and speaker tap selection are accessible from rear Speaker assembly Strobe assembly / Intensity selection Transparent plug, accessible only housing and from rear of homing; lens assembly factory.setting is 15 Cd Strobe intensit y viewing slot Surface Mounting Reference Showing Optional Wire Guard Surface mount conduit and box shown for reference 4"(lo2 mm) square box profile, 1-10 (38 mm) deep with 1-10 extension Optional 4905-9998 Wire Guard SN Surface mount adapter skirt, 3-3/16" (81 mm) deep, required for this mounting method: 4905-9946, Red; 4905-9947, White (conduit knockouts are provided on all four sides) TYCO. SIMPLEX and she product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). BSi IE Tyco Fire Protection Products• Westminster, MA" 01441-0001 • USA S4906-0003-8 5/2014 www.simp!ex-fire.com 0 2014 2)c0 Fire Protection .Thvducic. All rights reserved Allspecflcations and other infonntion shown were current as ofdoasment revision dateand are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING- BUILDING- MATERIALSLISTINGPROGRAM - - LISTING SERVICE LISTING No. 7320-0026:0247 Page 1 of I CATEGORY: 7320 -- SPEAKERS LISTEE: Simplex6 Technology Park Drive, Westford, MA 01886 Contact: Jim Goyette (978) 577-4074 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models 4903-9356, -9357, -9358, -9359, -9360, -9361, and Models 4906-9151 and -9153 TrueAlert Non-Addressable Wall Mount Speaker/Strobes. Models 4903-9196, -9197, -9198, and Models 4906-9154 and *..9160 TrueAlert Non-Addressable Ceiling Mount Speaker/Strobes. Suitable for indoor use only. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 25 or 70 Vrms, 1/4, 1/2, 1, and 2 Wattage Taps Candela: 4903-9356, -9359, -9196: 15cd -9197: 30cd -9357,-9360: 75cd -9358,-9361,-9198: 110cd 4906-9151, -9153, -9154, *16O: 15cd, 30cd, 75cd, ll0cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as hearing impaired speaker strobes for use with separately listed fire alarm control units. Refer to manufacturer's Installation Manual for details. These devices do not generate a temporal pattern code. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. *This speaker meets the requirements of UL Standard 1480. Revision 9-9-21 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the' item listed. - This listing should not be used to - verify correct - - V operational requirements or installation cntena. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Johnson Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 'Te!e((858)633910 Fax: (858) 633-9101 www.JohnsonControls.com Contractors License Detail for License # 986047 Busiess Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Eiiitity Partnership Issue Date 08/14/2013 Expire Date 08/31/2023 This license is current and active. All information below should be reviewed. C1 0 - ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82520648 for JOSEPH ANTHONY FEDDELER in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 07/26/2018 Workers Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number: MWC313943 Effective Date: 10/01/2018 Expire Date: 10/01/2022 Workers' Compensation History I I Other - Personnel listed on this license (currnt or disassociated) are listed on other licenses. 10/11/2019 REV.#: 0 PROJECT #: 480-