Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5928 FARNSWORTH CT; ; FPC2022-0136
PERMIT REPORT k1r,city of Carlsbad Print Date: 12/09/2022 Job Address: 5928 FARNSWORTH CT, CARLSBAD, CA 92008-7303 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2120701000 Track #: Valuation: $1,538,085.70 Lot #: Occupancy Group: Project #:. #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Permit No: FPC2022-0136 Status: Closed - Finaled Applied: 07/22/2022 Issued: 08/30/2022 Finaled Close Out: 12/09/2022 Final Inspection: INSPECTOR: Cheung, Nathaniel Project Title: Description: NATURAL ALTERNATIVES -SPRINKLER TI (613 HEADS) FPContractor: A AND D FIRE SPRINKLERS INC 7130 CONVOY CT SAN DIEGO, CA 92111-1019 (858) 277-3473 FEE AMOUNT FIRE Hourly Services (first hour). $188.00 FIRE Hourly Services (first hour) $188.00 FIRE Hourly Services (first hour) . . $188.00 FIRE NFPA 13 or 13R System > 100 heads $719.00 Total Fees: $1,283.00 Total Payments To Date: $1,283.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1 760-602-8561 f I www.carlsbadca.gov fta 2O22- N., 1 IF I Ems, N A Division of The Hiller Companies, Inc. NAI PHASE II 5928 FARNSWORTH COURT CARLSBAD, CA. FIRE SPRINKLER SUBMITTAL PRODUCT DATA Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. tqcu Worldwide Contacts www.tyco4ire.com Series TYFRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/ series-ty4rb-5-6K General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. L'LI1lLII The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.61K, 1/2 in. NPT TY323 .... Pendent 5.61K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, inc. (UL). Discharge Coefficient K=5.6 GPM/psi1" (80,6 LPM/bar14) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw.................Bronze Deflector..........................Bronze Page 1 of 4 NOVEMBER 2021 TFPI72 TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16" (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON * 6 7/16" I (11,1 mm) NOMINAL 2" (508 MAKE-IN ( _____ , mm) (°ff" - 2 2" 1-3/8 __ " ________ I , 3i1iuIi; (50,8 mm) (349 mm) I RENCH FLATS W 1/2" NPT** DEFLECTOR * 2-7/8"(73,o mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. FACE OF - (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) FLUSH 3/8±5/16" 17 - I (9,5±7,9 mm) : ¼.%Jl MOUNTING 1/8" J t I SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY 'TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 27/80 DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) (7964) 1/2" (12,7 mm) FLUSH I MOUNTING / 1/8° j SURFACE// (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON rle- aff/// WRENCH RECESS (USE ONLY END "A-) FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 6 t . PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPER BULB LIQUID COLOR NATURAL BRASS I POLYESTERCATURE I CHROME PLATED 5.6 1/2 In. NPT UPRIGHT (TY313) and PENDENT (1Y323) _______________ 135°F (57°C) Orange 1, 2, 3,4, 5, 6 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY323) Figures 4a and 5b 135°F (57°C) Orange 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc.. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54.428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. s. Installed with Style 15(1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI72 Page 4 of 4 P/Na_77X)X)XXX_________ SIN I SPRINKLER TEMPERATURE FINISH I RATINGS 370 1 5.6K UPRIGHT (1/2 in.NPT) TY313 371 1 5.6K PENDENT (1/2 in.NPT) I 1Y323 Notes: a. Use suffix for ISO 7-1 connection; for example, 77-370-4-175-I 1 I NATURAL BRASS PURE WHITE (RAL901O)a POLYESTER I SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) POLYESTER 9 I CHROME PLATED Notes: a. Eastern Hemisphere sales only 135 135-F (57-C) 155 155-F (68-C) 175 175-F (79-C) 200 200'F( 3-C) 286 286-F (141-C) TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-flre.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch-eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194481 Telephone .1-215-362-0700 0 2010 Johnson Control.. All right, reserved. All speclllcallons and other Isfermatiss chosen ow,s current an of document r.nlolen dott and am subject to change without notice. NA11ONALFIRE PROTECTION ASSOCIatiON and NFPAono r.glst.nod *.d.nno,koof National R,orvotoonfo,od.fon; TEFLON lloEsdamnAoi Th. CfemonaoCo,npotnyFc.U.0 Johnson ON Controls tqca Worldwide ,.co-ti.com Contacts Series RFII - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/series-rfii- 5_6-k-royal-flush-quick-cov General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers fea- turing a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensi- tive areas such as hotel lobbies, office buildings, churches, and restaurants. Each sprinkler includes a Cover Plate/ Retainer Assembly and a Sprinkler/ Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 in. (12,7 mm) of ver- tical adjustment to allow a measure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling installation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently pushing the ceiling product against the Pro- tective Cap. When ceiling installa- tion is complete, the Protective Cap is removed and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. See Figure 5. The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. MIL The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) 1Y3531 - 3 mm bulb TY3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Criteria section. TY3531 (3 mm Bulb) is UL Listed, C-UL Listed and NYC Approved (MEA 353-01-E) as Quick Response. TY3531 (3 mm Bulb) is EAC Approved and VdS Approved (Certificate No. G4090007). TY3531 (3 mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) as Standard Response. Note: FM and LPCB do not approve concealed sprinklers for quick response. TY3551 (5 mm Bulb) is UL Listed, C-UL Listed, EAC Approved, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Page 1 of 4 APRIL 2022 TFPIBI SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO H RETAINER LL L It SOLDER t~~COVER TABS (3) COVER PLATEIRETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY SUPPORT WITH THREAD CUP UNTIL 0 0S MOUNTING SURFACEIS EJECTION FLUSH WITH SPRING CEILING / TFPI8I Page 2 of 4 Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (1Y3551) Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Cover Plate 200°F (93°C) Sprinkler with 165°F (74°C) Cover Plate Discharge Coefficient K= 5.6 GPM/psi112 (80,6 LPM/barli2) Adjustment 1/2 in. (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ............................Bronze Support Cup...................Plated Steel Guide Pins..................Stainless Steel Deflector..........................Bronze Compression Screw..................Brass Bulb...............................Glass Cap .....................Bronze or Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Cover Plate .........................Brass Retainer............................Brass Ejection Spring ..............Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Johnson Controls at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFll Concealed Cover Plates having a factory applied finish. NiY(•Jl(iI Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler operation in a fire situation. 1/2 NPT FRAME SUPPORT CUP WITI ROLL FORW THREAD GUIDE PINS (2) Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 155°F (68°C) and 3/32 in. (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. DEFLECTOR LECTOR BOPPED POSITION) EALING SEMBLY CAP BULB PRESSION 'CREW 3-1/4 in. (82,6 mm) C: 2-3/8 to 2-5/8 in. (60,3 to 66,7 mm) 3/16 in. (4,8 mm) D: 1-3/4 to 2-1/4 in. (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 COVER PLATE RETAINER ASSEMBLY FACE OF SPRINKLER FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE 3/16 to 11/16 (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B CLEARANCE HOLE - DIAMETER DIMENSION MANUFACTURER DEFLECTOR PRESET GAP IN DROPPED 3/32 (2,4 mm) POSITION COVER PLATE DIAMETER DIMENSION A Do not attempt to compensate for insufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. See Figure 3. Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. See Figure 4. The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Pro- tective Cap. 'LIJtM As long as the Protective Cap remains in place, the system is considered "Out of Service' Step 6. After the ceiling has been completed with the 2-1/2 in. (63,5 mm) diameter clearance hole and in prep- aration for installing the Cover Plate/ Retainer Assembly, remove and discard the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. TFPIBI Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL BEVEL AS COVER \' SHOWN PLATE RETAINER ASSEMBLY AIR AND DUST LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) ASSOCIATION such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Step 7. When installing an Air and Dust Seal, see Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented accord- ing to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step S. Screw on the Cover Plate/ Retainer Assembly until the Retainer, shown in Figure 2, or the Air and Dust Seal, shown in Figure 5, contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer Assembly suf- ficiently to contact the ceiling, you must reposition the Sprinkler Fitting. Care and Maintenance The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 in. (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation Section. Exercise care to avoid damage to sprin- klers before, during, and after instal- lation. Replace sprinklers damaged by dropping, striking, wrench twist- ing, wrench slipping, or the like. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. See the Installation section. If you must remove a sprinkler, do not reinstall it or a replacement without reinstalling the Cover Plate/Retainer Assembly. If a Cover Plate/Retainer Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating, P/N* (specify): 155°F 168°C) 200'F (93'C) TY3531 51-792-1-155 51-792-1-200 TY3551 51.790.1-155 51-790-1-200 Use Suffix °I' for ISO 7-1 connection; for example. 51-792-1.155.1 Separately Ordered Cover Plate! Retainer Assembly: Specify: (temperature rating from below) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002).... 56-792-0-135 56-792-0-165 Brushed Brass.. 56-792-1-135 56-792-1-165 Brass..........56-792-2-135 56-792-2-165 Pure White (C) (RAL9010) .... 56-792-3.135 56-792-3.165 Signal White (RAL9003).... 56-792-4-135 56-792-4-165 Jet Black (RAL9005).... 56-792-6-135 56-792-6-165 Terra Brown (RAL8028) .... 56-792-7-135 56-792-7-165 Brushed Chrome........56-792-8-135 56-792-8-165 Chrome........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075 Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02022 Johnson Contrals. All rights reserved. All speclllc.11snn and surer InformatIon shown were Gwent an of document ,enlnlondaft and am subject to change wlthost notice. NATIONAL Johnson 011, 1S FIRE PROTECTION ASSOCIATION end NFPAssn rs5Istnrnd tiodnnsAual000*njlRrePtatuntlnnMnocjittn; Controls TEFLON Is I. tred.nce kal The Clnn.00n Cun,po ny FC .U.0 tqco® Worldwide Contacts www.tyco-fire.com Series TYIFRB - 56 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers described in this data sheet are quick response -standard coverage, dec- orative 3 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occu- pancies such as banks, hotels, shop- ping malls, etc. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are com- monly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The recessed version of the Series TY-FRB Horizontal Sidewall Sprinkler is intended for use in areas with a fin- ished wall. It uses a two-piece Style 10 Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush sidewall position, or a two-piece Style 20 Recessed Escutch- eon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush side- wall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Numbers TY3331................Horizontal TY3431..................Vertical JULY 2018 Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved NYC Approved (Refer to Table A for complete approval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/barl/2) Temperature Ratings Refer to Table A TFPI76 TFPI7G Page 2 of 6 1 - Frame DEFLECT( HAT 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector* 0- 9/16" WRENCH 1/2' (14,3 mm) FLATS NPT 1 - Frame DEFLECT( HAT 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * 0 9/16" WRENCH 1/2" (14,3 mm) FLATS NPT __~l I 7/16" I 1,11 mm) CENTERLINE I NOMINAL OF SPRINKLER MAKE-IN WATERWAY I L 1-1/2" —(38,1 mm) ESCUTCHEON PLATE SEATING 2-3/16" SURFACE STYLE 10 or 20 RECESSED ESCUTCHEON * Temperature rating is indicated on Deflector ** Pipe thread connectior per ISO 7-1 can be provided on special request ALL FINISHES EXCEPT POLY-STAINLESS *Temperature rating is indicated on Deflector 2-7/8" DIA. (73,0 mm) [f_. POLY-STAINLESS FINISH ONLY FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS Finishes Sprinkler: Refer to Table C Recessed Escutcheon: Signal or Pure White, Jet Black, Grey Aluminum, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw.................Bronze HSW Deflector .....................Bronze VSW Deflector.....................Copper Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel" Bulb...............................Glass Compression Screw .....L316 Stainless Steel" HSW Deflector ..............Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON "Type L316 stainless steel (UNS 31603) per ASTM A479/479M or OS EN 1008 WN1.4404. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB, 5.6 K-factor, Hor- izontal and Vertical Sidewall Sprin- klers are intended for fire protection systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Escutcheon, as applicable, is to be used for recessed horizontal installations. !_ 6* FLOW 5 —U _ -316" II4 I WRENCH 0'7 56mm) FLATS SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION FIGURE 2 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB VERTICAL SIDEWALL (TY3431) SPRINKLERS TFPI76 Page 3 of 6 Installation The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak tight 1/2 in. NPT sprinkler joint should be obtained with a torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque may distort the sprin- kler and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-FRB Horizontal and Vertical Sidewall Sprinkler Installation The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers must be installed in accordance with the fol- lowing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright position with the arrow on the Deflec- tor pointing away from the wall. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 5), With reference to Figure 1 or 2, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. * Temperature ** Pipe thread rating is connections indicated on per ISO 7-1 can Deflector. be provided on special request. 7/16' ESCUTCHEON (11,1 mm) PLATE SEATING NOMINAL SURFACE ,, ** 1/2 MAKE-IN NPT - (55, Series TY-FRB Recessed Horizontal Sidewall Sprinkler Installation The Series TY-FRB Recessed Horizon- tal Sidewall Sprinklers must be installed in accordance with this section. Step A. Recessed horizontal sidewall sprinklers are to be installed in the hori- zontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 10 or 20 Mounting Plate over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 6). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprin- kler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 10 or 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. 1 - Frame 4 - Bulb 7 - Ejection 2 - Button 5 - Compression Spring 3 - Sealing Screw Assembly 6 - Deflector* ARROW MUST POINT AWAY FROM AND BE PERPENDICULAR TO THE BACK WALL SURFACE Care and Maintenance The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Spriklers TFPI76 Page 4 of 6 - 5/8±1/4 (15,9±6,4 mm) MOUNTING FACE OF SURFACE - SPRINKLER FITTING CLOSURE 2-7/8" DIA. (73,0 mm) SERIES TY-FRB I /j DIA. (57,2mm) - MOUNTING PLATE 1/8" (3,2 mm) 1-1/4(31,8mm) 3/4(19,1 mm) 3/4" (19,1 mm) 1/4 (6,4 mm) FIGURE 3 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 1/2±1/8" (12,7±3,2 mm) MOUNTING I FACE OF SURFACE SPRINKLER CLOSURE FITTING SERIES 2-7 /8" DIA. 73,0 mm) TY-FRB 2-1/4" DIA. MOUNTING PLATE (3,2 mm) 1-1/4" (31,8 mm) 1/2"(12,7mm) 1"(25,4 mm) 1/4° (6,4 mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON WRENCH RECESS (END "A" USED FOR 1/2 NPT MODELS) FIGURE 5 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS V PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 W-TYPE 7 RECESSED SPRINKLER WRENCH FP176 05 of 6 SPRINKLER FINISH (See Note 11) K TYPE TEMP. BULB LIQUID NATURAL BR I CHROME PLATED POLYESTERc POLY_ LEAD STAINLESSC COATED HORIZ. SIDEWALL (TY3331) 135°F (57°C) Orange 1,2,3,4,9, 10 1,2,3, 9 1,2 1, 2,3.9 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 5.6 1/2 in. NPT RECESSED HORIZ. SIDEWALL (TY3331)a Figure 3 135°F (57°C) Orange 1, 2, 4, 9, 10 1, 2, 9 1,2 N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED 135°F (57°C) Orange 155°F (68°C) Red HORIZ. SIDEWALL (TY3331)b 1,2,3,4,9 N/A N/A 175°F (79°C) Yellow Figure 4 200°F (93°C) Green VERTICAL 135°F (57°C) Orange 155°F (68°C) Red 5.6 SIDEWALL 175°F (79°C) Yellow 1/2 in. NPT Installed Pendentor Upright 5. 6, 7, 8, 9 N/A 5, 6, 7, 9 200°F (93°C) Green 286°F (141°C) Blue NOTES: - Listed by Underwriters Laboratories, inc. (UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at 4 to 12 in. (100 to 300 mm) top of deflec- tor to ceiling distance. Listed by Underwriters Laboratories Inc. for use in Canada (C-UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 In. (100 to 300 mm) top of deflector to ceiling distance. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 in. (100 to 300 mm) top of deflector to ceiling distance. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04) at a4 to 8 in. (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. Listed by Underwriters Laboratories for use in Canada (C-UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 0948/06 & 007a104) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) at a 4 to 6 in. (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted lobe UL and C-Ui. Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. Installed with Style 10(1/2 in. NPT) 3/4 in.Totsl Adjustment Recessed Escutcheon. Installed with Style 20(1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon. Frame and deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprikler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprin- kler condition and the long term integ- rity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFPI76 Page 6 of 6 SPRINKLER FINISH K TYPE NATURAL BRASS I CHROME PLATED I POLYESTER LEAD COATED HORIZONTAL SIDEWALL (1Y3331) 250 PSI (17,2 BAR) or 1 RECESSED HORIZ. SIDEWALL (TY3331) 5. 1/2 in. 75PS1 (12,1 BAR) (SEE NOTE 1) NPT _________________________ VERTICAL SIDEWALL 175 PSI (12,1 BAR) (TY3431) NOTES: 1. The maximum working pressure of 250 pal (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE P/N 57 — XXX — X — XXX I I I SIN SPRINKLER [TTEMPERATURE FINISH I RATINGS It 378 I HORIZONTAL SIDEWALL I TY3331 375 1 VERTICAL SIDEWALL I TY3431 1 NATURAL BRASS - POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 - POLYESTER PURE WHITE (RAL9010)2 - POLYESTER SIGNAL WHITE (RAL9003) - POLYESTER JET BLACK (RAL9005)3 - POLYESTER 7 LEAD COATED 9 CHROME PLATED 135 135-F (57-C) 155 155°F (68°C) 175 175°F(79°C) 200 200°F(93°C) 286 286°F (141°C) NOTES: Available for TY3331 only. Eastern Hemisphere sales only. Available in 155F (68C) or 200F (93C temperature rating only. TABLE C PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Limited Recessed Escutcheon Ordering Specify: Style (10 or 20) Recessed Warranty Procedure Escutcheon with (specify*) finish, P/N (specify*) For warranty terms and conditions, visit www.tyco-fire.com Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). - Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Sprinkler Assemblies with NPT Thread Connections: Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Specify: Series TY-FRB (specify SIN), (specify K-factor), (specify) Horizontal Sidewall or Vertical Sidewall Sprinkler, Standard Response, Standard Coverage, (specify) temperature rating, (specify) finish or coating, P/N (specify from Table C) 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02018 Johnson Controls. All rights reserved. All specifications sod other Information shown wore current so of document revision dob and om subject to change without notice. Johnson 0101 NATIONAL FllttPROTECllONASSOCIATION and NFPA 5,. roglot.r.d usdemerko of Natlonol Ft. P,otsotlon Asnucl000x Controls 1EflONlsersclntirsdtod.miAofoaPoct Hydraulic Calculations for Project Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Location: 5928 FARNSWORTH COURT, CARLSBAD, CA 92008, Drawing Name: D3647 NAI PHASE II LOI Design Remote Area Number: Calculation Date: 7/20/2022 Occupancy Classification: Ordinary Group II Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm/ft2 1500ft2 (Actual 1536ft2) 130ft2 Pendent 19 0 N/A 9pm at Node: N/A 250.00 at Node: I Type: Allowance at Source (Safety Margin = 21.458) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 794.42 @ 76.768 Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent N/A Name of Contractor: A&D FIRE Address: 7130 CONVOY COURT, SAN DIEGO, CA 92111 Phone Number: 858-277-3473 Name of designer: DEVIN K. Authority Having Jurisdiction: CITY OF CARLSBAD Notes: Automatic peaking results Left: 76.768 Right: N/A Page 1 Hydraulic Graph Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 N 1.85 Remote Area Number: Date: 7/20/2022 100 Static Pressure 99.900 Water Supply Summary Sheet Stqç; - go- - Node: I 80--: 5.42 @ 76.768 11 794.4 with Hose Allowance at Source 70 - 66.600 60H 50— S atem demand curve 40-: 30 20 1 10 0_rLLLLLLUhmfuhhhl 0800 1600 2400 3200 4000 4800 5600 6400 7200 8000 Flow - gpm &,0 M.E.P.CAD. Inc. AutoSPRINK 2020 06.3.15.0 7/20/2022 9:51:06PM Page 2 1111 Summary Of Outfiowing_Devices Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 1228 28.96 26.00 5.6 26.743 Sprinkler 1229 29.35 26.00 5.6 27.461 Sprinkler 1230 29.75 26.00 5.6 28.223 Sprinkler 1234 27.62 26.00 5.6 24.324 Sprinkler 1235 26.24 26.00 5.6 21.957 Sprinkler 1236 28.86 26.00 5.6 26.561 Sprinkler 1237 29.25 26.00 5.6 27.284 Sprinkler 1238 29.66 26.00 5.6 28.045 Sprinkler 1239 29.33 26.00 5.6 27.425 Sprinkler 1240 29.07 26.00 5.6 26.952 Sprinkler 1241 26.08 26.00 5.6 21.688 Sprinkler 1242 29.34 26.00 5.6 27.451 c Sprinkler 1243 26.00 26.00 5.6 21.556 Sprinkler 1244 28.83 26.00 5.6 26.503 Sprinkler 1245 28.93 26.00 5.6 26.689 Sprinkler 1246 29.59 26.00 5.6 27.923 Sprinkler 1247 29.20 26.00 5.6 27.190 Sprinkler 1248 29.29 26.00 5.6 27.353 Sprinkler 1249 29.08 26.00 5.6 26.959 c Most Demanding Sprinkler Data , 0 M.E.P.CAD, Inc. jjAutoSPRlNK 2020 06.3.15.0 7/20/2022 9:51:07PM Page 3 Job Number: D-3647 Reonrt Dscriotinn Ordinry Groun II Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/2012022 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 99.900 66.600 1 4000.00 98.226 794.42 76.768 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1-0 Supply 76.768 544.42 1228 111-0% Sprinkler 26.743 28.96 1229 11-0V2 Sprinkler 27.461 29.35 1230 111 0u/2 Sprinkler 28.223 29.75 1234 91-0 Sprinkler 24.324 27.62 1235 9-0 Sprinkler 21.957 26.24 1236 110h/2 Sprinkler 26.561 28.86 1237 1V0h/z Sprinkler 27.284 29.25 1238 11,01/2 Sprinkler 28.045 29.66 1239 11,-0% Sprinkler 27.425 29.33 1240 9-0 Sprinkler 26.952 29.07 1241 9-0 Sprinkler 21.688 26.08 1242 91-0 Sprinkler 27.451 29.34 1243 91-0 Sprinkler 21.556 26.00 1244 11-0 Sprinkler 26.503 28.83 1245 111-01/2 Sprinkler 26.689 28.93 1246 1V-0'/2 Sprinkler 27.923 29.59 1247 11-0% Sprinkler 27.190 29.20 1248 9-0 Sprinkler 27.353 29.29 f,© M.E.P.CAD, Inc. 4LAutoSPRlNK 2020 v16.3.15. 7/20/2022 9:51:09PM Page 4 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1249 9-0 Sprinkler 26.959 29.08 II -3-5% 74.558 12 -3'-5% 74.991 13 -3-5% 77.454 14 -3-5V2 77.804 16 -3-5'h 78.418 17 -3'-5'h 78.126 18 -3-5'/2 78.664 230 23-3 59.432 825 12-10% 28.955 826 17-10% 29.175 827 12'-10Y2 30.002 829 11-6% 34.374 845 I1 I-61/2 34.082 848 12'-2Y2 28.063 854 12-8 23.315 862 12-5V2 28.803 863 12-5% 29.022 864 12-5% 29.844 866 111-6% 33.928 876 12-8 22.970 877 11-6% 33.884 880 12-9 29.554 ,© M.E.P.CAD, Inc. 41AutoSPRINK 2020 v16.3.15. 7/20/2022 9:51:09PM Page Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 882 12'-9 29.030 885 12-9 28.864 889 12-8 22.822 894 12-5% 28.770 896 12'-5V2 29.005 897 12-5!/2 29.756 899 11-6V2 33.808 906 11,61/2 33.801 910 12-9 29.485 912 12-9 29.242 914 12-9 28.862 ,© M.E.P.CAD, Inc. AutoSPRiNK 2020 06.3.15. 7/20/2022 9:51:09PM Page 6 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as _________________ Fitting (Foot) ___________ N Friction Loss Per Unit (psi) Elev(Pe) Node 2 Eiev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 1243 9'-O 5.6 26.00 1 (See Notes) 4'-5'A 120 21.556 • • • Route I Sprinkler, 2E(2'-O), P0(5'-0) '.o 0.211435 -1.581 889 12-8 26.00 1.0490 13'-5'A 2.846 889 12'-8 1% 7'-O 120 22.822 876 12'-8 26.00 1.6820 0.021212 7-0 0.148 876 12'-8 26.08 1/2 4'-6 120 22.970 Flow (q) from Route 2 0.076686 854 12'-8 52.08 1.6820 4'-6 0.345 854 17-8 26.24 1% (See Notes) 18'- 51/2 120 23.315 Flow (q) from Route 3 3E(3'-1 '/z) 27' 27!-10Y20.163136 0.199 848 12-2% 78.32 1.6820 4.550 848 12'-2'/2 27.62 1% (See Notes) T- 0 1/2 120 28.063 Flow (q) from Route 4 E(3'-1 Y2), P0(9'-1 1) 13'-0',4 0.285259 0.289 845 1161/2 105.94 1.6820 20'-1 5.730 845 11-6% 350.42 4 6'-4 120 34.082 Flow (q) from Route 5 0.046042 829 11-6'/2 456.36 4.2600 6'-4 0.292 829 11'-6% 88.06 4 (See Notes) 245'-4Y2 120 34.374 Flow (q) from Route 8 4fT(21'-1), 13fE(8'-11 %), P0(2 6'-4) 22 -10% 0.063813 -5.076 230 23'-3 544.42 4.2600 472'-3 30.134 230 23-3 6 (See Notes) 230'1Y2 120 59.432 160'-11 1/2 0.009084 11.573 11 -3'-5Y2 544.42 6.3570 PO(37'-8'A), 7E(17'-7)391'-1 3.553 11 -3'-5Y2 6 (See Notes) 150 74.558 LtE(9'-O) 91-0 0.008937 12 -3'-5% 544.42 5.8600 48'-5% 0.433 12 -3'-5Y2 6 (See Notes) 17'11 120 74.991 3LtE(11'-4), BFP(-2.000) 33'-11Y2 0.009084 13 -3'-5'/2 544.42 6.3570 51'-0 2.463 13 -3'-5Y2 6 (See Notes) 91 1 150 77.454 T(30'-O) 30'-0 - 14 -3-5% 544.42 5.8600 F 0.008937 39'-1 0.349 ,©M.E.P.CAD, Inc. 4AutoSPRINK 2020 v16.3.15.0 7/20/2022 9:51:1113M Page 7 9:51:1112M Page 8 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pf Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) Frlctlon(Pf) 14 -3'-5% 8 (See Notes) 280'0 150 77.804 E(1 8'-O) 18'-0 0.001081 17 -3'-5% 354.31 7.6800 298'-0 0.322 17 -3'-5% 8 (See Notes) 290'-3% 150 78.126 T(35'-O) 36-0 0.000897 16 -3'-5'h - 354.31 7.9800 325'-3Y2 0.292 16 -3-5Y2 190.11 6 (See Notes) 13'7 150 78.418 Flow (q) from Route 20 E(14'-O) 0.246 14'-O 0.008937 18 -3-5% 544.42 5.8600 27'-7 18 -3-5',4 6 (See Notes) 4'-5Y2 140 78.664 Water Supply 0.007248 -1.929 11-0 544.42 6.2800 4'-5Y2 0.032 250.00 76.768 Hose Allowance At Source Total(Pt) Route I 1 794.42 1241 91-0 5.6 26.08 1 (See Notes) 4'5% 120 21.688 ..... Route 2 ... Sprinkler, 2E(2'-O), PO(5'-O) 91-0 0.212635 -1.581 876 12'-8 26.08 1.0490 13'-5% 2.862 22.970 Total(Pt) Route 2 1235 91-0 5.6 26.24 1 (See Notes) 4'-8 120 21.957 •••• • Route 3 "..' Sprinkler, 2E(2'-O), PO(5'-O) 0.2 15073 f -1.581 854 12'-8 26.24 1.0490 13'-8 2.938 23.315 Total(Pt) Route 3 1234 91-0 5.6 27.62 1 (See Notes) 8'-8 120 24.324 ..... Route 4'.... Sprinkler, 4E(2'O), PO(5'O) 13'-o 0.236436 J -1.382 848 12'-2Y2 27.62 1.0490 21'-8 5.121 28.063 Total(Pt) Route 4 1244 11'-0 5.6 28.83 1 (See Notes) 2'-4 120 26.503 '•'' Route 5'.'.' Sprinkler, 2E(2'-O), PO(5'-O) 91-0 0.255964 -0.632 894 12'-5Y2 28.83 1.0490 11'-4 2.899 894 12-5% 1% 91-2 120 28.770 0.025679 896 12'-5% 28.83 1.6820 9'-2 0.235 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7120/2022 Pipe Information Node I Eiev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Eiev(Pe) Node 2 Eiev 2 (Foot) Total Flow (Q) Actual ID Total I (Foot) Friction(Pf) 896 12'5Y2 28.93 1% 8'-1 120 29. 005 Flow (q) from Route 7 0.092874 897 1Z-5'/z 57.76 1.6820 8'-1 0.751 897 12'-5'h 29.59 1% (See Notes) 63 120 29.756 Flow (q) from Route 17 E(3'-1 1/2), PO(9'-11) 13'-OYz 0.199632 0.397 899 11-6'/z 87.35 1.6820 1831% 3.655 899 11'-6% 87.57 9'7'/2 120 33.808 Flow (q) from Route 10 0.007810 877 11'-6% 174.92 4.2600 0.075 877 11'-6'h 87.74 4 2'-8Y2 120 33.884 Flow (q) from Route 9 0.016569 866 1161/a 262.66 4.2600 2'-8'A 0.045 866 11'-6% 87.77 5'-5'% 120 33.928 Flow (q) from Route 6 0.028244 845 11'-6Y2 350.42 4.2600 5'-5'/2 0.154 34.082 Total(Pt) Route 5 1236 11'-0'/2 5.6 28.86 1 (See Notes) 2-2 120 26.561 ""Route6 Sprinkler, 2E(2'-O), P0(5-0) 91-0 0.256474 -0.623 862 12-5% 28.86 1.0490 11 '-2 2.866 862 12'-5% I % 8'-6 120 28.803 0.025730 863 12'-5'h 28.86 1.6820 8'-6 0.219 863 12-5'/a 29.25 11/2 8'-g 120 29.022 Flow (q) from Route 12 0.093923 0.000 864 12-5'/2 58.11 1.6820 8'-9 0.822 864 12-5% 29.66 1 ',c (See Notes) 63 120 29.844 Flow (q) from Route 18 E(3'-11/2), PO(9'-11) 13'-O% 0.20 1398 0.397 866 11'-6'A 87.77 1.6820 18'-3'h 3.687 33.928 Total(Pt) Route 6 1245 111-0% 5.6 28.93 1 (See Notes) 2'-5 120 26.689 Route 7 • • Sprinkler, 2E(2'-O), PO(5'-O) 0.257623 -0.623 896 12'-5 'h 28.93 1.0490 11'-5 2.940 29.005 Total(Pt) Route 7 ,0 M.E.P.CAD, Inc. 4AutoSPRiNK 2020 v1 6.3.15.0 7/20/2022 9:51:11PM Page 9 Page 10 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Eiev, 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _______________ Friction(Pf) 1228 111-0Y2 5.6 28.96 1 (See Notes) 7-8 120 26.743 ••••• Route 8..... Sprinkler, 2E(2'-O), PO(5'-O) g 0.258100 -0.804 825 12'-10Y2 28.96 1.0490 111-8 3.017 825 12'-1O'A 1v2 8'6 120 28.955 0.025894 826 12'-10'/z 28.96 1.6820 8'-6 0.220 826 12'-10Y2 29.35 1% 8'g 120 29.175 Flow (q) from Route 16 0.094502 827 12'-lO'/z 58.31 1.6820 0.827 827 12-10'A 29.75 1% (See Notes) 5'8 120 30.002 Flow (q) from Route 19 E(3'-1 1/2), P0(9'-1 1) 13'-0Y2 0.202619 0.578 829 116h/2 88.06 1.6820 18'-8'h 3.794 34.374 Total(Pt) Route 8 1240 91-0 5.6 29.07 1 (See Notes) 5'-2Y2 120 26.952 ..... Route 9..... Sprinkler, 2E(2'-O), PO(5'-O) 91-0 0.259966 -1.617 882 12'-9 29.07 1.0490 14'-2Y2 3.695 882 12'-9 29.34 1% (See Notes) 2414 120 29.030 Flow (q) from Route 15 E(3'-1 %) 3'-1Y2 0.094824 880 12'-9 58.41 1.6820 5'-6'h 0.524 880 12'-9 29.33 1Y2 (See Notes) 5'10Y2 120 29.554 Flow (q) from Route 14 E(3'-1Y2), PO(9'-11) 13'-0% 0.201276 0.524 877 11-6% 87.74 1.6820 18'-11 3.806 33.884 Total(Pt) Route 9 1249 91-0 5.6 29.08 1 (See Notes) 4.7 120 26.959 .... Route 10 ..... Sprinkler, 2E(2'-O), PO(5'-O) 91-0 0.260032 -1.626 914 12'-g 29.08 1.0490 13'-7 3.528 914 12'-9 1v2 14'7 120 28.862 0.026087 912 12'-9 29.08 1.6820 14'-7 0.380 912 12'-9 29.29 7-7 120 29.242 Flow (q) from Route 13 0.094679 910 17-9 58.36 1.6820 2'-7 0.243 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FlttlnglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _______________ Friction(Pf) 910 17-9 29.20 11/2 (See Notes) 5'10'A 120 29.485 Flow (q) from Route 11 E(3'-1 V2), PO(9'-11) 1301,4 0.200536 0.524 906 11'-6% 87.57 1.6820 18'-11 3.792 906 11'-6Y2 4 3'-7 120 33.801 0.002171 899 11'-6% 87.57 4.2600 3-7 0.008 33.808 Total(Pt) Route 10 1247 11-0% 5.6 29.20 1 (See 1' Notes) 4'-7'h 120 27.190 "" Route ll•••• Sprinkler, E(2'-0), PO(5-0) 0.262092 -0.750 910 12'-9 29.20 1.0490 11'-7Y2 3.045 29.485 Total(Pt) Route 11 1237 11'-0Yz 5.6 29.25 1 (See Notes) T 1'11Y2 120 27.284 Route 12 Sprinkler, E(2'-O), PO(5'-O) 7'-0 0.262933 -0.623 863 17-5'/2 29.25 1.0490 8-11% 2.361 29.022 Total(Pt) Route 12 1248 91-0 5.6 29.29 1 (See Notes) I 4'-3% 120 27.353 ••••• Route 13..... Sprinkler, 2E(2'-O), PO(5'-O) 91-0 0.263543 -1.617 912 17-9 29.29 1.0490 13'-3',4 3.506 29.242 Total(Pt) Route 13 1239 11-0Y2 5.6 29.33 1 (See Notes) T 3'-10'A 120 27.425 ••••. Route 14..... Sprinkler, E(2'-O), PO(5'-O) 7-0 0.264187 -0.750 880 12'-9 29.33 1.0490 10'-10V2 2.879 29.554 Total(Pt) Route 14 1242 91-0 5.6 29.34 1 (See Notes) 4'-5'A 120 27.451 ••'•'Route 15." Sprinkler, E(2'-0), PO(5'-O) 7'-0 0.264416 -1.617 885 17-9 29.34 1.0490 11'-5Y2 3.030 885 17-9 11//2 6'-3 120 28.864 0.026527 882 17-9 29.34 1.6820 6'-3 0.166 29.030 Total(Pt) Route 15 1229 1101/2 5.6 29.35 1 (See Notes) I 2'-6 120 27.461 "•• Route 16'.... Sprinkler, E(2'-O), PO(5'-O) 7-0 0.264506 -0.804 826 17-10% 29.35 1.0490 9'-6 2.518 ,© M.E.P.CAD, Inc. 4IAutoSPRlNK 2020 v16.3.15.0 7/20/2022 9:51:11PM Page 11 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _______________ Frlctlon(Pf) 29.175 Total(Pt) Route 16 1246 11'-O% 5.6 29.59 1 (See Notes) I 7-1 Y2 120 27.923 Route 17..... Sprinkler, E(2'-O), PO(50) 0.268618 -0.623 897 12'-5 Y2 29.5 9 1.0490 9'-1',4 2.457 29.756 Total(Pt) Route 17 1238 11'-O'A 6 1 (See Notes) I 1'-11Y2 120 28.045 "•• Route 18..... Sprinkler, E(2'-O), PO(5'-O) 7'-O 0.269709 12-5% T29.1166 -0.623 864 1.0490 8'-11Y2 2.422 29.844 Total(Pt) Route 18 1230 11'-0% 5.6 29.75 1 (See Notes) 2'-6 120 28.223 .... Route 19 ..... Sprinkler, E(2'-O), PO(5'-O) 1 T-0 0.271291 -0.804 827 12'-10Y2 29.75 1.0490 9'-6 2.583 30.002 Total(Pt) Route 19 14 -3'-5Y2 354.31 8 (See Notes) 1599'-9'% 150 77.804 ••••• Route 2O••... Flow (q) from Route I 8E(18'-O), 2EE(9'-0), T(35'-O) ir-o 0.000342 16 -3'-5% 190.11 7.6800 j j7991/ 0.614 78.418 Total(Pt) Route 20 ,© M.E.P.CAD, Inc. JAutoSPRlNK 2020 06.3.15.0 7120/2022 9:51:11PM Page 12 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 lEauivalent Pioe Lenaths of Valves and Fittinas (C120 onlv IC Value Multiplier • Actual Inside Diameter 4.87 Value Of C 100 130 140 150 I \ Factor Schedule 40 Steel Pipe Inside Diameter J I Multiplying Factor 0.713 1.18 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 900 cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 900 Elbow EE 450 Elbow Eel 11Y4° Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 900 Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,© M.E.P.CAD. Inc. iJAutoSPRlNK 2020 v1 6.3.15.O 7/20/2022 9:51:11PM Page 13 Hydraulic Calculations for Project Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Location: 5928 FARNSWORTH COURT, CARLSBAD, CA 92008, Drawing Name: D3647 NAI PHASE II L02 Design Remote Area Number: Calculation Date: 7/20/2022 Occupancy Classification: Ordinary Group II Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm/ft2 1500ft2 (Actual 914ft2) 130ft2 Upright, Pendent 21 0 N/A gpm at Node: N/A 250.00 at Node: I Type: Allowance at Source (Safety Margin = 21.998) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 852.61 @ 75.995 Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent N/A Name of Contractor: A&D FIRE Address: 7130 CONVOY COURT, SAN DIEGO, CA 92111 Phone Number: 858-277-3473 Name of designer: DEVIN K. Authority Having Jurisdiction: CITY OF CARLSBAD Notes: Automatic peaking results Left: N/A Right: N/A 1$ M.E.P.CAD, Inc. jIAutoSPRlNK 2020 06.3.15.0 7/20/2022 8:46:36PM Page 1 Hydraulic Graph Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 N 1.85 Remote Area Number: Date: 7/2012022 100 : Static Pressure 99.900 Water Supply Summary Sheet 90 Node: I 80-7- 602.61 @ 75.995 852.61 with Hose Allowance at Source 70H - 0O0.0066.6O0 I 50 stem demand curve - 40 20 10- 11111111 111111111 111111111 1111111_II I_I_I_I_I_I_I I_I_I_I_I_I_I_I .I_I_I_I_I_I_I_I_I 0- 0800 1600 2400 4000 4000 5600 6400 7200 8000 Flow - gpm E&© M.E.P.CAD, Inc. 431 AutoSPRINK 2020 06.3.15.0 7/20/2022 8:46:38PM Page 2 11111 Rnnnrt flnscrioti Summary Of Outflowing Devices Job Number: D-3647 NEENEENE nn Ordinary (rniin II Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 1108 32.16 26.00 5.6 32.973 Sprinkler 1109 32.19 26.00 5.6 33.051 Sprinkler 1110 32.30 26.00 5.6 33.273 Sprinkler 1121 31.98 26.00 5.6 32.603 Sprinkler 1122 32.01 26.00 5.6 32.681 Sprinkler 1123 32.12 26.00 5.6 32.900 Sprinkler 1127 26.00 26.00 5.6 21.556 Sprinkler 1128 26.03 26.00 5.6 21.607 Sprinkler 1129 26.13 26.00 5.6 21.764 Sprinkler 1130 26.26 26.00 5.6 21.986 Sprinkler 1131 26.20 26.00 5.6 21.886 Sprinkler 1132 27.38 26.00 5.6 23.904 Sprinkler 1133 28.19 26.00 5.6 25.336 Sprinkler 1138 27.32 26.00 5.6 23.800 Sprinkler 1139 27.35 26.00 5.6 23.857 Sprinkler 1140 27.46 26.00 5.6 24.040 Sprinkler 1141 27.42 26.00 5.6 23.980 Sprinkler 1142 28.38 26.00 5.6 25.679 Sprinkler 1143 28.97 26.00 5.6 26.763 Sprinkler 1350 27.81 26.00 5.6 24.656 Sprinkler 1361 28.96 26.00 5.6 26.738 Most Demanding Sprinkler Data I&@ M.E.P.CAD Inc. 4AutoSPRINK 2020 v16.3.15.0 7/20/2022 8:46:40PM Page 3 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Supply Analysis Node Name Static (psi) Residual Flow (psi) (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 99.900 66.600 1 4000.00 97.992 852.61 75.995 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes I 1-0 Supply 75.995 602.61 1108 25-11Yz Sprinkler 32.973 32.16 1109 25-11'A Sprinkler 33.051 32.19 1110 25-11Y2 Sprinkler 33.273 32.30 1121 25-11Ya Sprinkler 32.603 31.98 1122 25'-111% Sprinkler 32.681 32.01 1123 25'-11Y2 Sprinkler 32.900 32.12 1127 25-11% Sprinkler 21.556 26.00 1128 25-11Y2 Sprinkler 21.607 26.03 1129 25-11Y2 Sprinkler 21.764 26.13 1130 25'-11Y2 Sprinkler 21.986 26.26 1131 25'-11% Sprinkler 21.886 26.20 1132 25'-1111% Sprinkler 23.904 27.38 1133 25'-11% Sprinkler 25.336 28.19 1138 25'-11Y2 Sprinkler 23.800 27.32 1139 25'-11Y2 Sprinkler 23.857 27.35 1140 25-11% Sprinkler 24.040 27.46 1141 25-11% Sprinkler 23.980 27.42 1142 25'-11% Sprinkler 25.679 28.38 ,© M.E.P.CAD, Inc. 4jAutoSPRlNK 2020 06.3.15. 7/20/2022 8:46:43PM Page 4 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1143 25-1W2 Sprinkler 26.763 28.97 1350 23-8 Sprinkler 24.656 27.81 1361 23-8 Sprinkler 26.738 28.96 11 4-51/2 73.342 12 4-51/2 73.865 13 -3'-5',4 76.424 14 -3-5% 76.846 16 -3-5% 77.587 17 -3-5% 77.235 18 4-51/2 77.884 27 23-8 57.974 617 23-8 43.641 660 23-8 42.839 676 23-8 42.101 678 23-8 42.101 681 23-8 42.101 683 23-8 42.101 689 23-8 42.101 702 23-8 36.251 703 23-8 36.334 704 23'-8 36.570 705 23-8 36.785 709 23-8 38.076 Page 5 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/2012022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 715 23-8 41.292 726 23-8 35.858 727 23-8 35.940 728 23-8 36.174 729 23'-8 36.386 733 23-8 37.663 736 23-8 40.847 738 23-8 24.673 739 23-8 24.729 740 23-8 24.900 741 23-8 25.142 743 23-8 27.234 744 23-8 28.795 749 23-8 40.762 778 23-8 27.121 779 23-8 27.182 780 23-8 27.382 781 23-8 27.886 782 23-8 29.168 783 23-8 30.350 788 23-8 40.641 850 23-8 25.555 852 23-8 26.019 ,© M.E.P.CAD, Inc. 41AutoSPRlNK 2020 06.3.15. 7/20/2022 8:46:43PM Page 6 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 895 23-8 28.221 1061 23'-0Y2 Sprinkler 7.000 Sprinkler 1062 23-1 Sprinkler 7.000 Sprinkler 1063 23-1 Sprinkler 7.000 Sprinkler 1064 23-1 Sprinkler 7.000 Sprinkler 1065 23-1 Sprinkler 7.000 Sprinkler 1077 23-1 Sprinkler 7.000 Sprinkler 1078 23-1 Sprinkler 7.000 Sprinkler 1079 23-1 Sprinkler 7.000 Sprinkler 1080 23-1 Sprinkler 7.000 Sprinkler 1081 23-1 Sprinkler 7.000 Sprinkler 1089 23'-0'/z Sprinkler 7.000 Sprinkler 1090 23'-0V2 Sprinkler 42.101 Sprinkler 1091 23-1 Sprinkler 7.000 Sprinkler 1092 23-1 Sprinkler 7.000 Sprinkler 1103 23-1 Sprinkler 7.000 Sprinkler 1104 23-0'/2 Sprinkler 7.000 Sprinkler 1105 23-1 Sprinkler 21.556 Sprinkler 1106 23'-1 Sprinkler 7.000 Sprinkler 1107 23'-1 Sprinkler 7.000 Sprinkler 1118 23'-1 Sprinkler 21.556 Sprinkler 1119 23-1 Sprinkler 7.000 Sprinkler 1120 23'-1 Sprinkler 7.000 Sprinkler © M.E.P.CAD, Inc. 4IIAutoSPRlNK 2020 06.3.15. 7/20/2022 8:46:43PM Page 7 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/2012022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as ___________________ __ Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 EIev2 (Foot) Total Flow (Q) Actual ID __ ______ Total (Foot) _____________ Friction(Pf) 1127 25'-ll% 5.6 26.00 1 (See Notes) 3'-0Y2 120 21.556 ••"• Route l••••• Sprinkler, E(2'-O), P0(5-0) 7'O 0.211435 0.994 738 23'-8 26.00 1.0490 10'-0% 2.123 738 23'-S 2 8'-lO% 120 24.673 0.006317 739 23'-8 26.00 2.1570 8'-10Y2 0.056 739 23'-8 26.03 2 7'-6 120 24.729 Flow (q) from Route 2 0.022797 740 23'-8 52.03 2.1570 7'-6 0.171 740 23 '-8 26.13 2 5'-O 120 24. 900 Flow (q) from Route 3 0.048393 6-0 741 23'-8 78.16 2.1570 0.242 741 23'-8 26.26 2 6-0 120 25.142 Flow (q) from Route 5 0.082700 850 23'-8 104.41 2.1570 6-0 0.414 850 23'-8 26.20 2 3'-8'A 120 25.555 Flow (q) from Route 4 0.125133 852 23'-8 130.61 2.1570 3/ 0.464 852 23'-8 27.81 2 6'-9% 120 26.019 Flow (q) from Route 11 0.178832 6'-9% 743 23'-8 158.42 2.1570 1.214 743 23'-8 27.38 2 6-6 120 27.234 Flow (q) from Route 8 0.240176 6-6 744 23'-8 185.80 2.1570 1.561 744 23'-8 28.19 2 (See Notes) 26 '-O% 120 28.795 Flow (q) from Route 12 PO(12'-3V2) 12'-3% 0.311900 749 23'-8 213.99 2.1570 38'-4% 11.967 749 23'-8 195.86 4 7-3 120 40. 762 Flow (q) from Route 6 0.037737 736 23'-8 409.84 4.2600 2'-3 0.085 736 23'-8 96.11 8'-0 120 40.847 Flow (q) from Route 16 0.055723 715 23-8 505.95 4.2600 8'-O 0.446 , 0 M.E.P.CAD, Inc. AutoSPRINK 2020 06.3.15.0 7/20/2022 8:46:45PM Page 8 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K.Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 2 (Foot) Total Flow (Q) Total Elev Actual ID (Foot) _______________ Friction(Pf) 715 23'-8 96.65 4 10'-6 120 41.292 Flow (q) from Route 19 0.077000 689 23'-8 602.61 4.2600 10'-6 0.808 689 23'-8 4 9'-7 120 42.101 0.077000 660 23'-8 602.61 4.2600 9'-7 0.738 660 23'-8 4 10'-5 120 42.839 0.077000 617 23'-8 602.61 4.2600 10'-5 0.802 617 23'-8 4 (See Notes) 141'4'A 120 43.641 5fE(8'-11Y2) 0.077000 27 23'-8 602.61 4.2600 186'-2 14.333 27 23'-8 6 (See Notes) 22912'% 120 57.974 cplg(7'-6Y2) 6fE(177), E(177) 100'-7 0.010962 11.753 11 -3'-5Ya 602.61 6.3570 329'-9'A 3.615 11 '% 6 (See Notes) 39'5% 150 73.342 LtE(9'-O) 0.010784 12 -3'-5% 602.61 5.8600 48'-5% 0.523 12 -3'-5% 6 (See Notes) 17'1 120 73.865 3LtE(11'-4), BFP(-2.000) 33'-11Y2 0.010962 13 -3'-5Y2 602.61 6.3570 51'-0 2.559 13 -3'-5% 6 (See Notes) 911 150 76.424 T(30'-O) 0.010784 14 -3'-5Y2 602.61 5.8600 39'-1 0.421 14 -3'-5% 8 (See Notes) 280'0 150 76.846 E(18'-O) 18'-0 0.001305 17 -3'-5% 392.18 7.6800 298'-0 0.389 17 -3'-5Y2 8 (See Notes) 290'3% 150 77.235 T(35'-0) 0.001083 16 -3-5'/2 392.18 7.9800 326-3'A 0.352 16 -3'-5% 210.43 6 (See Notes) 13'7 150 77.587 Flow (q) from Route 22 E(14'-O) 14'-O 0.010784 18 -3'-5% 602.61 5.8600 27'-7 0.297 ,,© M.E.P.CAD, Inc. jAutoSPRlNK 2020 v16.3.15.0 7/20/2022 8:46:45PM Page 9 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) (psi) Length (Foot) C Factor Total(Pt) Notes Fifing/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as flSg4iSSt ,sSI..p Fitting (Foot) Pt Friction Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _______________ Frictlon(Pf) 18 -3'-5% 6 (See Notes) I 4'-5% 140 77.884 Water Supply 0.008746 -1.929 I 11-0 602.61 6.2800 I 4'5% 0.039 250.00 75.995 Hose Allowance At Source Total(Pt) Route I 1 852.61 1128 25'-11% 5.6 26.03 1 (See Notes) 3'0y2 120 21.607 ''''' Route 2..... Sprinkler, E(2'-O), PO(5'-O) 7'-O 0.211900 0.994 739 23'-8 26.03 1.0490 10'-O% 2.128 24.729 Total(Pt) Route 2 1129 26-11Y2 5.6 26.13 1 (See Notes) T 3'O'A 120 21.764 '''''Route 3''''' Sprinkler, E(2'-O), PO(5'-O) f 7'-0 0.213322 0.994 740 23'-8 26.13 1.0490 I 10'-O% 2.142 24.900 Total(Pt) Route 3 1131 26-11Y2 5.6 26.20 i (See Notes) J 3'-6Y2 120 21.886 '''''Route 4'"'' Sprinkler, 2E(2'-O), P0(5-0) 0.214426 0.984 850 23'-8 26.20 1.0490 I 12'-6% 2.685 25.555 Total(Pt) Route 4 1130 25'-11% 5.6 26.26 1 (See Notes) J 3'-0'A 120 21.986 "Route 5"•' Sprinkler, E(2'-0), PO(5'-O) I 7' 0.215332 741 23'-8 26.26 1.0490 I 10'-O% 2.162 25.142 Total(Pt) Route 5 1138 25'-11% 5.6 27.32 1 (See Notes) 3'-0% 120 23.800 "Route 6" Sprinkler, E(2'-O), PO(5'-O) 7'-0 0.231721 0.994 778 23-8 27.32 1.0490 10'-O% 2.327 778 23'-8 2 8'-10Y2 120 27.121 0.006923 779 23'-8 27.32 2.1570 8'-i 0% 0.061 779 23'-8 27.35 2 8'-0 120 27.182 Flow (q) from Route 7 0.024985 780 23'-8 54.67 2.1570 8'-O 0.200 ,0 M.E.P.CAD, Inc. 4AutoSPRlNK 2020 v16.3.15.0 7/20/2022 8:46:45PM Page 10 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/2012022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Totai(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Eiev(Pe) Node 2 Eiev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _______________ Friction(Pf) 780 23'-8 27.46 2 9'-6 120 27.382 Flow (q) from Route 10 0.053043 781 23'-8 82.13 2.1570 9'-6 0.504 781 23'-8 27.42 2 -__3'-8Y2 120 27.886 Flow (q) from Route 9 0.090386 895 23'-8 109.55 2.1570 3'-81h 0.335 895 23'-8 28.96 2 6'-91h 120 28.221 Flow (q) from Route 14 0.139488 782 23'-8 138.51 2.1570 6'-9Y2 0.947 782 23'-8 28.38 2 61-0 120 29.168 Flow (q) from Route 13 0.196916 783 23'-8 166.89 2.1570 1.181 783 23'-8 28.97 2 (See Notes) 26'-6'A 120 30.350 Flow (q) from Route 15 PO(12'-3Y2) j231/ 0.264783 788 23'-8 195.86 2.1570 38'-10% 10.291 788 23'-8 4 12'-6 120 40.641 0.009628 749 23'-8 195.86 4.2600 12'-6 0.120 40.762 Total(Pt) Route 6 1139 25'-11% 5.6 27.35 1 (See Notes) 3'O½ 120 23.857 ... Route 7'.... Sprinkler, E(2'-O), PO(5'-O) 0.232228 0.994 779 23'-8 27.35 1.0490 101-0% 2.332 27.182 Total(Pt) Route 7 1132 25'-11% 5.6 27.38 1 (See Notes) 3'1, 120 23.904 "...Route 8..... Sprinkler, E(2'-O), PO(5'-O) 0.232654 0.994 743 23'-8 27.38 1.0490 101-0% 2.336 27.234 Total(Pt) Route 8 1141 25'-111% 5.6 27.42 1 (See Notes) 3'6'A 120 23.980 • "Route 9"..' Sprinkler, 2E(2'-O), PO(5'-O) 91-0 0.233337 0.984 781 23'-8 27.42 1.0490 12'-6',4 2.922 27.886 Total(Pt) Route 9 45PM Page 11 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FlttinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (120 and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) ______________ Friction(Pf) 1140 25'-11% 5.6 27.46 1 (See Notes) 3'- 0 1/2 120 24.040 Route 10..... Sprinkler, E(2'-O), PO(5'-O) 7'-0 0.233878 0.994 780 23'-8 27.46 1.0490 10'-01/2 2.349 27.382 Total(Pt) Route 10 1350 23'-8 5.6 27.81 1 (See Notes) 0'-81A 120 24.656 Route 11 Sprinkler, PO(5'-O) 6-0 0.239417 852 23'-8 27.81 1.0490 5'-81h 1.363 26.019 Total(Pt) Route 11 1133 26-11% 5.6 28.19 1 (See Notes) 3'-0Y2 120 25.336 " Route 12 ..... Sprinkler, E(2'-O), PO(5'-O) 0.245517 0.994 744 23'-8 28.19 1.0490 10'0'/2 2.465 28.795 Total(Pt) Route 12 1142 25'-11Y2 5.6 28.38 1 (See Notes) 3'-O% 120 25.679 . . . Route 13..... Sprinkler, E(2'-O), PO(5'-O) 0.248588 0.994 782 23'-8 28.38 1.0490 100h/2 2.496 29.168 Total(Pt) Route 13 1361 23'-8 5.6 28.96 1 (See Notes) 0'9 120 26.738 Route 14..... Sprinkler, PO(5'-O) 0.258055 f 895 23'-8 28.96 1.0490 6-9 1.434 28.221 Total(Pt) Route 14 1143 26-11Y2 5.6 28.97 1 (See Notes) 3'-0Y2 120 26.763 .... Route 15..... Sprinkler, E(2'-O), PO(5') 0.258281 0.994 783 23'-8 28.97 1.0490 1001/2 2.594 30.350 Total(Pt) Route 15 1121 25'-11'A 5.6 31.98 1 (See Notes) 2'-3% 120 32.603 ""Route 16..... Sprinkler, PO(5'-O) 5'-O 0.310022 0.994 726 23'-8 31.98 1.0490 7'-3% 2.261 726 23'-8 2 8'-10'h 120 35.858 0.009262 727 23'-B 31.98 2.1570 8'-lO'A 0.082 727 23'-8 32.01 2 7'-0 120 35.940 Flow (q) from Route 17 0.033427 728 23'-8 63.99 2.1570 7'-O 0.234 , 0 M.E.P.CAD, Inc.,41 AutoSPRINK 2020 06.3.15.0 7/20/2022 8:46:45PM Page 12 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pt Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) Friction(Pf) 728 23'-8 32.12 2 3'-0 120 36.174 Flow (q) from Route 18 0.070946 729 23-8 96.11 2.1570 3'-O 0.213 729 23'-8 2 18'-0 120 36.386 0.070946 733 23'-8 96.11 2.1570 18'-O 1.277 733 23'-8 2 (See Notes) 32614 120 37.663 PO(12'-3%) 12'-3% 0.070946 736 23'-8 96.11 2.1570 44'-lO% 3.183 40.847 Total(Pt) Route 16 1122 25'-I1Yz 5.6 32.01 1 (See Notes) 2'3% 120 32.681 ••••• Route 17••••• Sprinkler, PO(5'-O) 0.310701 0.994 727 23-8 32.01 1.0490 7'-3'A 2.266 35.940 Total(Pt) Route 17 1123 26-11Y2 5.6 32.12 1 (See Notes) 2'-3Y2 120 32.900 ••••• Route 18••••• Sprinkler, PO(5'-O) 5'-0 0.312634 0.994 728 23'-8 32.12 1.0490 7'31h 2.280 36.174 Total(Pt) Route 18 1108 25'-11% 5.6 32.16 1 (See Notes) 231/2 120 32.973 .... Route 19..... Sprinkler, PO(5-0) 6-0 0.313273 0.994 702 23'-8 32.16 1.0490 7!-3'/2 2.284 702 23-8 2 8'-10'A 120 36.251 0.009359 703 23'-8 32.16 2.1570 8'-10'A 0.083 703 23'-8 32.19 2 7-0 120 36.334 Flow (q) from Route 20 0.033778 704 23'-8 64.35 2.1570 7-0 0.236 704 23-8 32.30 2 3'-0 120 36.570 Flow (q) from Route 21 0.071689 705 23'-8 96.65 2.1570 3'-O 0.215 705 23-8 2 18'-0 120 36.785 0.071689 709 23'-8 96.65 2.1570 18'-O 1.290 L M.E.P.CAD, Inc. jAutoSPRlNK 2020 06.3.15.0 7/20/2022 8:46:45PM Page 13 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FittinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction (psi) Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Frictlon(Pf) 709 23'-8 2 (See Notes) 32'-6'4 T 120 38.076 PO(17-3'/2) 1231/2 I 0.071689 715 23'-8 96.65 2.1570 44'-10Y2 3.217 41.292 Total(Pt) Route 19 1109 26-11Y2 5.6 32.19 i (See 1 Notes) 2'-3'h 120 33.051 Route 20•'... Sprinkler, PO(5'-O) 6-0 0313958 0.994 703 23'-8 32.19 1.0490 I 7'-3'/z 2.289 36.334 Total(Pt) Route 20 1110 26-11Y2 5.6 32.30 i (See Notes) I 2'-3% 120 33.273 Route 21 Sprinkler, PO(5'-O) [ 5 0.315910 0.994 704 23'-8 32.30 1.0490 i 7'-3% 2.304 36.570 Total(Pt) Route 21 14 -3-514 392.18 8 (See Notes) I 1599'-9% 150 76.846 ••••• Route 22••••• Flow (q) from Route I 8E(18'-O), 2EE(9-0), T(35'-O) 197'-0 0.000412 16 -3-5% 210.43 7.6800 I 1796'-9% 0.741 77.587 Total(Pt) Route 22 ,© M.E.P.CAO, Inc. JAutoSPRINK 2020 06.3.15.0 7/20/2022 8:46:45PM Page 14 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 lEquivalent Pipe Lengths of Valves and Fittings (Cr120 only) Value Actual Inside Diameter 4.87 Value Of C 100 130 140 150 I \ =Factor Schedule 40 Steel Pipe Inside Diameter / I Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 450 Elbow Eel 1114 Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow fig Flange FN Floating Node IT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,0 M.E.P.CAD, Inc. lAutoSPRlNK 2020 06.3.15.0 7/20/2022 8:46:45PM Page 15 Hydraulic Calculations for Project Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Location: 5928 FARNSWORTH COURT, CARLSBAD, CA 92008, Drawing Name: D3647 NAI PHASE II L02 Design Remote Area Number: Calculation Date: 7/20/2022 Occupancy Classification: Ordinary Group II Density Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: No. of nozzles calculated: In-rack Demand: Hose Streams: 0.20gpm/ft2 1500ft2 (Actual 1596ft2) 130ft2 Pendent 22 0 N/Agpm at Node: N/A 250.00 at Node: I Type: Allowance at Source (Safety Margin = 23.794) Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 895.22 @ 74.018 Type of System: Volume of Dry/PreAction/Antifreeze/OtherAgent N/A Name of Contractor: A&D FIRE Address: 7130 CONVOY COURT, SAN DIEGO, CA 92111 Phone Number: 858-277-3473 Name of designer: DEVIN K. Authority Having Jurisdiction: CITY OF CARLSBAD Notes: Automatic peaking results Left N/A Right: N/A 1$ M.E.P.CAD, Inc. JAutoSPRlNK 2020 v16.3.15.0 7/20/2022 8:56:34PM Page 1 Hydraulic Graph Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 N 1.85 Remote Area Number: Date: 7/20/2022 100 : Static Pressure 95900 Water Supply Summary Sheet 9 0 Node: I -b - _____ _______ ________ __________ ___________ 80-i 645.22 @ 74.018 895.22 with Hose Allowance 70-H 4000.00 95.600 60-H I 50-H CL stem demand curve 40-H 30 20H 10-h - 0_iUULLLLLItIIIIIII 111111111 111111111 1 IIIIIIIl 1 III 111111 1 II 1 111111 1 liii III I hl I I I I I I I I 0800 1800 2400 3200 4000 4800 5600 6400 7200 8000 Flow - gpm ,© M.E.P.CAD, Inc. j AutoSPRINK 2020 06.3.15.0 7/20/2022 8:56:36PM Page 2 Summary Of buff lowing Devices 11111 Job Number: D-3647 Report Description: Ordinary Group I Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 1061 29.67 26.00 5.6 28.074 Sprinkler 1062 29.71 26.00 5.6 28.149 Sprinkler 1063 29.85 26.00 5.6 28.420 Sprinkler 1064 30.15 26.00 5.6 28.995 Sprinkler 1065 30.66 26.00 5.6 29.981 Sprinkler 1077 29.16 26.00 5.6 27.111 Sprinkler 1078 29.20 26.00 5.6 27.184 Sprinkler 1079 29.34 26.00 5.6 27.447 Sprinkler 1080 29.42 26.00 5.6 27.600 Sprinkler 1081 29.65 26.00 5.6 28.040 Sprinkler 1089 26.00 26.00 5.6 21.556 Sprinkler 1090 26.81 26.00 5.6 22.917 Sprinkler 1091 28.35 26.00 5.6 25.632 Sprinkler 1092 28.33 26.00 5.6 25.600 Sprinkler 1103 27.50 26.00 5.6 24.113 Sprinkler 1104 27.28 26.00 5.6 23.736 Sprinkler 1105 30.34 26.00 5.6 29.354 Sprinkler 1106 31.20 26.00 5.6 31.046 Sprinkler 1107 30.42 26.00 5.6 29.508 Sprinkler 1118 30.33 26.00 5.6 29.326 Sprinkler 1119 31.41 26.00 1 5.6 31.459 1 Sprinkler 1120 30.43 26.00 5.6 29.522 Most Demanding Sprinkler Data 0 M.E.P.cAD, Inc. 4jAutoSPRlNK 2020 v16.3.15.0 7/20/2022 8:56:37PM Paqe 3 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Supply Analysis Node Name Static (psi) Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) Water Supply 99.900 66.600 4000.00 97.812 895.22 74.018 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 676 23-8 26.983 678 23-8 27.038 681 23-8 28.787 683 23-8 30.257 689 23-8 38.073 705 23-8 34.725 709 23-8 35.049 715 23-8 37.982 729 23' 34.693 733 23-8 35.018 736 23-8 37.963 821 23'-8 34.813 843 23-8 34.780 1108 25'-11Y2 Sprinkler 7.000 Sprinkler 1109 25'-11% Sprinkler 7.000 Sprinkler 1110 25'-11% Sprinkler 7.000 Sprinkler 1121 25-11% Sprinkler 7.000 Sprinkler 1122 25'-11% Sprinkler 7.000 Sprinkler 1123 26-11Y2 Sprinkler 7.000 Sprinkler Page 4 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1127 25-11Y2 Sprinkler 7.000 Sprinkler 1128 25-11Y2 Sprinkler 7.000 Sprinkler 1129 25-11Y2 Sprinkler 7.000 Sprinkler 1130 25'-11Y2 Sprinkler 7.000 Sprinkler 1131 25'-11Y2 Sprinkler 7.000 Sprinkler 1132 25-11'A Sprinkler 7.000 Sprinkler 1133 25-11'/2 Sprinkler 7.000 Sprinkler 1138 25-11% Sprinkler 7.000 Sprinkler 1139 25-111/2 Sprinkler 7.000 Sprinkler 1140 25-111/2 Sprinkler 7.000 Sprinkler 1141 25'-11% Sprinkler 7.000 Sprinkler 1142 25-11Y2 Sprinkler 7.000 Sprinkler 1143 25-11V2 Sprinkler 7.000 Sprinkler 1 1-0 Supply 74.018 645.22 1061 23'-0% Sprinkler 28.074 29.67 1062 23-1 Sprinkler 28.149 29.71 1063 23'-1 Sprinkler . 28.420 29.85 1064 23'-1 Sprinkler 28.995 30.15 1065 23-1 Sprinkler 29.981 30.66 1077 23-1 Sprinkler 27.111 29.16 1078 23-1 Sprinkler 27.184 29.20 1079 23-1 Sprinkler 27.447 29.34 1080 23-1 Sprinkler 27.600 29.42 &© M.E.P.CAD, Inc. ft1iAutoSPRlNK 2020 v16.3.15. 7/20/2022 8:56:40PM Page 5 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 1081 23-1 Sprinkler 28.040 29.65 1089 23-0% Sprinkler 21.556 26.00 1090 23-0Yz Sprinkler 22.917 26.81 1091 23'-1 Sprinkler 25.632 28.35 1092 23'-1 Sprinkler 25.600 28.33 1103 23-1 Sprinkler 24.113 27.50 1104 23-0V2 Sprinkler 23.736 27.28 1105 23-1 Sprinkler 29.354 30.34 1106 23-1 Sprinkler 31.046 31.20 1107 23-1 Sprinkler 29.508 30.42 1118 23-1 Sprinkler 29.326 30.33 1119 23-1 Sprinkler 31.459 31.41 1120 23-1 Sprinkler 29.522 30.43 11 -3'-5% 71.018 12 -3-5% 71.611 13 -3-5% 74.246 14 -3-5% 74.724 16 -3'-5!/2 75.565 17 -3-5% 75.165 18 4-51/2 75.902 27 23-8 55.163 607 23-8 30.091 608 23-8 30.171 ,© M.E.P.CAD, Inc. 4JAutoSPRlNK 2020 06.3.15. 7/20/2022 8:56:40PM Page 6 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes 609 23-8 30.463 610 23-8 31.081 611 23-8 32.141 617 23-8 38.898 628 23'-8 28.947 630 234 29.025 632 23-8 29.307 648 23-8 30.175 652 23-8 31.762 660 23-8 38.340 673 23-8 26.757 675 23-8 26.769 ,© M.E.P.CAD, Inc. 4IAutoSPRlNK 2020 v16.3.15. 7/20/2022 8:56:40PM Page 7 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) ___________ Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 1089 23'-0Y2 5.6 26.00 1 (See Notes) 6'10'A 120 21.556 Route I Sprinkler, 2T(5'-O), 2E(2'-O), PO(5'-O) ig'-o 0.211435 -0.271 673 23'-8 26.00 1.0490 25'-lO% 5.472 673 23-8 2 1'-11 120 26.757 0.006317 675 23'-8 26.00 2.1570 1'-Il 0.012 675 23'-8 27.50 2 8'-11 120 26.769 Flow (q) from Route 4 0.024002 676 23'-8 53.50 2.1570 8'-ll 0.214 676 23'-8 26.81 2 11-I 120 983 Flow (q) from Route 2 0.050885 678 23'-8 80.31 2.1570 1,-i 0.056 678 23 27.28 2 0388 20'-O 120 Flow (q) from Route 3 0.087413 681 23'-8 107.59 2.1570 20'-O 1.748 681 23'-8 28.35 2 10'-11 120 28.787 Flow (q) from Route 6 683 23'-8 135.94 2.1570 0.134742 10'-Il 1.470 683 23'-8 28.33 2 (See Notes) 28'6% 120 30.257 Flow (q) from Route 5 PO(12'-3%) 12'-3',4 0.191254 689 23'-8 164.28 2.1570 40'-lO% 7.816 689 23'-8 184.13 4 9'-7 120 38.073 _______ Flow (q) from Route 16 0.027943 660 23'-8 348.40 4.2600 9'-7 0.268 660 23'-8 146.77 'I 10'-5 120 38.340 Flow (q) from Route 7 0.053545 617 23'-8 495.17 4.2600 10'-5 0.558 617 23'-8 150.05 4 (See Notes) 141'4Y2 120 38.898 Flow (q) from Route 12 5fE(8'-ll%) 0.087376 27 23'-8 645.22 4.2600 186'-2 16.265 27 23'-8 6 _ (See Notes) 229'2% 120 55.163 cplg(7-6%) 6fE(12'-7), E(17'-7) 100'-7 0.012439 11.753 11 -3'-5% 645.22 6.3570 329'-9% 4.102 .© M.E.P.CAD, Inc. 4 AutoSPRINK 2020 v16.3.15.0 7/20/2022 8:56:42PM Page 8 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as -.gam, - Fitting (Foot) ___________ N Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) ______________ Friction(Pf) _________ 11 -3'-5% 6 (See Notes) 39'5% 150 71.018 LtE(9'-O) 9,-0 0.012237 12 -3'-5% 645.22 5.8600 4851,4 0.593 12 -3'-5% 6 (See Notes) 17'1 120 71.611 3LtE(11'4), BFP(-2.000) 33'-11Y2 0.012439 13 4-51/2 645.22 6.3570 51'-0 2.635 13 -3'-5% 6 (See Notes) 91-I 150 74.246 T(30'-O) 0.012237 14 -3'-5% 645.22 5.8600 39'-1 0.478 14 -3'-5Y2 8 (See Notes) 280'0 150 74.724 E(1 8'.0) 18'-0 0.001481 17 -3'-5'/z 419.91 7.6800 298'-0 0.441 17 -3'-5'/2 8 (See Notes) 290'3% 150 75.165 T(3T(36-0) 0.001229 16 -3-5% 419.91 7.9800 325'-3% 0.400 16 -3'-5Y2 225.31 6 (See Notes) 13'7 150 75.565 Flow (q) from Route 23 E(14'-O) 0.337 0.012237 18 -3'-5Y2 645.22 5.8600 27'-7 18 -3-5% 6 (See Notes) 4'5% 140 75.902 Water Supply 0.009924 -1.929 I 11-0 645.22 6.2800 4-5% 0.044 250.00 74.018 Hose Allowance At Source Total(Pt) Route I 1 895.22 1090 23'-0'h 5.6 26.81 1 (See Notes) 5'-5 120 22.917 ••••• Route 2..... Sprinkler, 2E(2'-O), T(5'-0), PO(5'-O) 14'-0 0.223750 -0.280 676 23'-8 26.81 1.0490 19'-5 4.346 26.983 Total(Pt) Route 2 1104 23'-0% 5.6 27.28 1 _______ (See I Notes) 5-5% 120 23.736 ''.. Route 3 Sprinkler, T(5'-O), PO(5'-O) 101-0 ________ 0.231136 -0.271 678 23'-B 27.28 1.0490f 15'-5% 3.574 27.038 Total(Pt) Route 3 0 M.E.P.CAD, Inc. 4jAutoSPRlNK 2020 06.3.15.0 7/20/2022 8:56:42PM Page 9 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) when applicable, are added Fixed Pressure Losses, directly to (PQ and shown as Fitting (Foot) N Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) _______________ Friction(M) 1103 23'-1 5.6 27.50 1 (See Notes) 5'-5'2 120 24.113 ••••• Route 4••••. Sprinkler, E(2'.0), P0(5'-O) I 7'-0 0.234535 4262 675 23'-8 27.50 1.0490 12'-5Y2 2.918 26.769 Total(Pt) Route 4 1092 23'-1 5.6 28.33 1 (See Notes) J 5'-10 120 25.600 •••• Route 5 ..... Sprinkler, 2E(2'-O), T(5'-O), PO(5'-O) 14'-0 0.247883 -0.262 683 23'-8 28.33 1.0490 19'-10 4.918 30.257 Total(Pt) Route 5 1091 23'-1 5.6 28.35 1 (See Notes) I 3'-9 120 25.632 ... ••Route 6••••• Sprinkler, T(5'-0), PO(5'-O) 10'-O 0.248170 -0.262 681 23'-8 28.35 1.0490 13'-9 3.417 28.787 Total(Pt) Route 6 1077 23'-1 5.6 29.16 1 (See Notes) 1'0Y2 120 27.111 .... Route 7••••• Sprinkler, E(2'-O), PO(5'-O) 7'-0 0.261386 -0.262 628 23-8 29.16 1.0490 80h/2 2.098 628 23'-8 2 101-0 120 28.947 0.007809 630 23-8 29.16 2.1570 10'-O 0.078 630 23'-8 29.20 2 101-0 120 29.025 Flow (q) from Route 8 0.028187 632 23'-8 58.36 2.1570 101-0 0.282 632 23-8 29.34 2 (See Notes) 10'2% 120 29.307 Flow (q) from Route 9 0.059882 648 23'-8 87.69 2.1570 14'-6 0.868 648 23'-8 29.42 2 (See Notes) 1121,4 120 30.175 Flow (q) from Route 10 4'3%) 0.102266 652 23'-8 117.11 2.1570 15'-6% 1.587 652 23'-8 29.65 2 (See Notes) 30'0% 120 31.762 Flow (q) from Route 11 P0(17.3%) 123h, 0.155263 660 23'-8 146.77 2.1570 42'-4V2 6.578 38.340 Total(Pt) Route 7 ,© M.E.P.CAD, Inc. 4flAutoSPRINK 2020 06.3.15.0 7/20/2022 8:56:42PM Page 10 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (0) Actual ID Total (Foot) _______________ Frlctlon(Pf) 1078 23'-1 5.6 29.20 1 (See Notes) 11-0%120 27.184 ••"• Route 8..... Sprinkler, E(2'-O), PO(5'-O) 7'-0 0.262036 8!-0%2.103 -0.262 630 23'-8 29.20 1.0490 29.025 Total(Pt) Route 8 1079 23'-1 5.6 29.34 1 (See Notes) 11-0%T 120 27.447 •••• Route 9 ..... Sprinkler, E(2'-O), PO(5'-O) ' 0.264381 8!-0% -0.262 632 23'-8 29.34 1.0490 2.122 29.307 Total(Pt) Route 9 1080 23'-1 5.6 29.42 i (See Notes) 1'-8 120 27.600 ••••• Route lO•"•• Sprinkler, 2E(2'-O), P0(5-0) ' 0.265749 -0.262 648 23'-8 29.42 1.0490 101-8 2.836 30.175 Total(Pt) Route 10 1081 23'-1 5.6 29.65 1 (See Notes) 2'-9% 120 28.040 Route 11 Sprinkler, E(2'-O), T(5'-O), PO(5'-O) 12' 0.269661 -0.262 652 23'-8 29.65 1.0490 149h/2 3.984 31.762 Total(Pt) Route 11 1061 23'-0Y2 5.6 29.67 1 (See Notes) 1'-5% 120 28.074 .... Route 12..... Sprinkler, E(2'-0), PO(5'-O) 7'-0 0.269963 -0.262 607 23'-8 29.67 1.0490 8'-51h 2.279 607 23'-8 2 101-0 120 30.091 0.008065 608 23'-8 E2971 2.1570 10'-O 0.081 608 23'-8 2 101-0 120 30.171 Flow (q) from Route 13 0.029112 609 23'-8 59.38 2.1570 10'-O 0.291 609 23-8 29.85 2 101-0 120 30.463 Flow (q) from Route 14 0.061845 610 23'-8 89.24 2.1570 10'-O 0.618 610 23'-8 30.15 2 101-0 120 31.081 Flow (q) from Route 15 0.105973 611 23'-8 119.39 2.1570 10'-O 1.060 ,© M.E.P.CAD, Inc. 4IAutoSPRlNK 2020 06.3.15.0 7/20/2022 8:56:42PM Page 11 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Node I Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes FlttinglDevice (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Eiev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _______________ Frlction(Pf) 611 23-8 30.66 2 (See 29'5Y2 120 32.141 (q) from Route 20 P0(1 2'-3%) Notes)Flow 0.161755 12'-3Y2 617 23'-8 150.05 2.1570 41'-9Y2 6.757 38.898 Total(Pt) Route 12 1062 23'-1 5.6 29.71 1 (See Notes) 1'5'h 120 28.149 Route 13"" Sprinkler. E(2'-O), PO(5'-O) 0.270629 -0.262 608 23'-8 29.71 1.0490 8'-5'A 2.285 30.171 Total(Pt) Route 13 1063 23'-1 5.6 29.85 1 (See Notes) 1'-5Y2 120 28.420 "•• Route 14 .... . Sprinkler, E(2'-O), P0(5-0) 7-0 0.273037 -0.262 609 23-8 29.85 1.0490 8'-5'A 2.305 30.463 Total(Pt) Route 14 1064 23'-1 5.6 30.15 1 T (See Notes) 1'-5Y2 120 28.995 "•• Route 15..... Sprinkler. E(2'-O), PO(5'-O) 7'-O 0.278146 -0.262 610 23'-8 30.15 1.04j 85h/2 2.348 31.081 Total(Pt) Route 15 1118 23'-1 5.6 30.33 1 (See Notes) 60h/2 120 29.326 .... Route 16 Sprinkler, 2E(2 '.0), T(5'-O), PO(5'-O) 14'-0 0.281084 -0.262 729 23-8 30.33 1.0490 20'-01A 5.629 729 23'-8 2 10'-5 120 34.693 0.008398 843 23'-8 30.33 2.1570 10'-5 0.087 843 23'-8 31.41 2 7'-7 120 34.780 Flow (q) from Route 22 0.031282 733 23'-8 61.74 2.1570 7'-7 0.237 733 23'-8 30.43 2 (See Notes) 326% 120 35.018 Flow (q) from Route 19 P0(1 2'-3%) 12'-3'A 0.065649 44'-10'/2 2.946 736 23'-8 92.16 2.1570 736 23'-8 4 81-0 120 37.963 0.002387 715 23'-8 92.16 4.2600 8'-O 0.019 ,© M.E.P.CAD, Inc. '.AutoSPRINK 2020 06.3.15.0 7/20/2022 8:56:42PM Page 12 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/2012022 Pipe Information Node I Elev (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Eiev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) _______________ Friction(Pf) 715 23-8 91.96 4 T J 10'-6 120 37.982 Flow (q) from Route 17 0.008588 689 23'-8 184.13 4.2600 10'-6 0.090 38.073 Total(Pt) Route 16 1105 23'-1 5.6 30.34 1 (See Notes) 6'0Y2 120 29.354 ••••• Route 17..... Sprinkler, 2E(2'-O), T(5'-0), PO(5'-O) 14'-0 0.281326 -0.262 705 23'-8 30.34 1.0490 20'-O'h 5.634 705 23-8 2 10'-5 120 34.725 0.008405 821 23'-8 30.34 2.1570 10'-5 0.088 821 23'-8 31.20 2 7-7 120 34.813 Flow (q) from Route 21 0.031102 709 23'-8 61.54 2.1570 7-7 0.236 709 23'-8 30.42 2 (See Notes) 3261,4 120 35.049 Flow (q) from Route 18 PO(12'-3'A) 12'-3Y2 0.065386 715 23'-8 91.96 2.1570 44'-101h 2.934 37.982 Total(Pt) Route 17 1107 23'-1 5.6 30.42 1 (See Notes) 6'-6% 120 29.508 Route 18 Sprinkler. 2E(2'-O), T(5'-0), PO(5'-O) 14'-0 0.282698 -0.262 709 23'-8 30.42 1.0490 20'-6',4 5.802 35.049 Total(Pt) Route 18 1120 23'-1 5.6 30.43 1 (See Notes) 6'-4Y2 120 29.522 ••••• Route 19••••• Sprinkler, 2E(2'-O), T(5'-0), PO(5'-O) 14'-0 0.2828 19 -0.262 733 23'-8 30.43 1.0490 20'-4Y2 5.758 35.018 Total(Pt) Route 19 1065 23'-1 5.6 30.66 1 (See Notes) 1'5Y2 120 29.981 Route 20..... Sprinkler, E(2'-O), PO(5'-O) 0.286884 -0.262 611 23'-8 30.66 1.0490 85h/2 2.422 32.141 Total(Pt) Route 20 1106 23'-1 5.6 31.20 1 (See Notes) 2'-7 120 31.046 ••••• Route 21 ..... Sprinkler, 3E(2'-O), PO(5'-0) 0.296303 -0.262 821 23'-8 31.20 1.0490 13'-7 4.028 34.813 Total(Pt) Route 21 f,© M.E.P.CAD, Inc. ,j AutoSPRINK 2020 06.3.15.0 7/20/2022 8:56:42PM Page 13 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node I (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent (q) Equiv. Fitting (Foot) Pt Friction Elev(Pe) Length) Fixed Pressure Losses, Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit when applicable, are added Total _______________ (Foot) (Q) (Foot) (Foot) (psi) Friction(M) directly to (Pt) and shown as 1119 23'-1 5.6 31.41 1 (See 2'-11'h 120 31.459 .... Route 22..... Notes) Sprinkler, -0.262 843 23-8 31.41 1.0490 0.299945 2E(2'-O), PO(5'-O) 11'-11Y2 3.583 34.780 Total(Pt) Route 22 14 -3-51A 419.91 8 (See 1599'-9'h 150 74.724 ..... Route 23..... Notes) Flow (q) from Route I 16 -3'-5'h 225.31 7.6800 0.000468 8E(18'-O), 2EE(9-O), T(35'-O) 1796'-9'A 0.841 75.565 Total(Pt) Route 23 7/20/2022 8:56:42PM Page 14 Job Name: NATURAL ALTERNATIVES INTERNATIONAL PH. 2 Remote Area Number: Date: 7/20/2022 lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) Value Actual Inside Diameter 4.87 Value Of C 100 130 140 150 I \ =Factor Schedule 40 Steel Pipe Inside Diameter / Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet Pry Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Cap © M.E.P.CAD, Inc. jAutoSPRINK 2020 06.3.15.0 7120/2022 8:56:42PM Page 15