Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2677 STATE ST; ; FPC2019-0228
PERMIT REPORT Lcity of Carlsbad Print Date: 09/24/2020 Job Address: 2677 STATE ST, CARLSBAD, CA 92008-1627 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2030542502 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Constructio.i Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0228 Status: Closed - Finaled Applied: 09/25/2019 Issued: 10/21/2019 Finaled Close Out: 09/24/2020 Inspector: Final Inspection: Project Title: Description: TOWN HOUSE -NEW FIRE ALARM FOR NEW CONSTRUCTION MIXED USE PROJECT (38 DEVICES, 3 STORIES) Applicant: FPContractor: FIRE ETC FIRE ETC FRANCHOT DAVIS 2190 MAIN ST 2190 MAIN ST SAN DIEGO, CA 92113-2218 SAN DIEGO, CA 92113 (619) 525-7286 (760) 859-7443 FEE AMOUNT FIRE New Alarm System $1,265.00 Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A TOWN HOUSE - STATE STREET 2677 STATE STREET CARLSBAD, CA 92008 FIRE ALARM SYSTEM CONTRACTOR FIRE ETC. 2190 MAIN STREET SAN DIEGO, CA 92113 PH: (760) 672-5914 CA LIC. C10-1028927 TABLE OF CONTENTS ITEM QTY. PART # - DESCRIPTION MANUFACTURER 1 1 SK-6700 Addressable Fire Alarm Control Panel Silent Knight 2 2 NP12-12 Battery 12 Volt, 12.0 Amp/Hr. Genesis 3 8 SK-Minimon Addressable Mini Monitor Module Silent Knight 4 1 SK-PHOTO-W Addressable Smoke Detector Silent Knight 5 1 SK-HAET-ROR Addressable Rate-Of-Rise Heat Detector Silent Knight 6 2 B300-6 Detector Mounting Base, 6" Silent Knight 7 3 SK-Pull-SA Addressable Pull Station Silent Knight 8 6 MHW Mini-Horn System Sensor 9 5 SRL Strobe System Sensor 10 9 P2RL Horn/Strobe, Multi-Candela System Sensor 11 2 P2RK Horn/strobe, Multi-Candela, Outdoor System Sensor 12 NA 18/2 FPL Fire Cable Genesis Cable 13 NA 14/2 FPL Fire Cable Genesis Cable 4 Honeywell DSILENT !GJICHT Addressable Fire Alarm Control Par 6700 Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that is a direct replacment for the 5700 FACP. The 6700 can be configured to achieve a point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor (SK) sensors and 50 SK modules or 50 Hochiki (SD) devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. The 6700 also has a built-in, dual-line POTS and IP communicator with additional cellular options available. 6700 The 6700 system can be enhanced by adding modules such as the The 6700 supports a variety of devices, including 6860 remote annunciator which also has four programmable function the 6860, 5860, and 6855 remote annunciators, buttons to help automate tasks and reduce time spent at the panel. 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, SWIFT" wireless compatibility provides options for wireless detection 5895XL power module, and SK or SD devices. through a Class A mesh network. It is ideal for hard-to-wire locations, buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS Capable of providing up to 100 points to satisfy smaller installation needs Connect up to 17 panels on one site with convenient single- point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models Convenient field-upgradeab(e firmware Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting 6860 annunciator with a 4 x 40 large display Four user- programmable buttons minimize time spent executing complex or routine tasks Built-in USB interface for convenient and quick programming Programmable date setting for automatic and convenient Daylight Saving Time changes JumpStart auto programming reduces installation time 125 software zones and 125 output groups for flexible design options SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS General Alarm (Red): Flashes if in alarm; solid when alarm is silenced Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced System TroubLe (YeLLow): Flashes if a trouble condition exists; solid when trouble is silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal USER INTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4-to 7-digit operator's code. PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart" auto programming minimizes programming required to start a new system. The built-in keypad, or the 6860,5860 or 6855 remote annunciators give you on-site access to current system programming. Programming can also be accomplished using the Windows'-based Honeywell Fire Software Suite (HFSS) program. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a PC running Microsoft Windows". ADDITIONAL INFORMATION Twisted-unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NPFA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services ULListed:52766 CSFM 7165-0559:0501 FDNY COA# 6250 ORDERING INFORMATION 6700: Addressable Fire Alarm Control Panel. (Red cabinet) COMPATIBLE ANNUNCIATORS 6860:440 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860:420 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855:420 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614,350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.siLentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. Page 2 of 4— 351607:B 9/26/2018 SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (13519, white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (1900F), white SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B300-6(-IV): 6" base for SK-W Series B21OLP: 6" mounting base B501(-BL,-IV,-WHITE): 4"flangeless base B501: 4" Flangeless mounting base BZOOS(-W,-WH): Intelligent sounder base B200S: Intelligent sounder base 13200S-LF(-IV,-WH): Low-Frequency intelligent sounder base B200S-LF: Low-frequency intelligent sounder base 8224RB(-IV,-WH): Relay base B224RB: Relay base 13224B1(-IV,-WH): Isolator base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-6113: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6' relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) S0500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for the 5D505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F-150°F (0°C-37°C). SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R' indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.silentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi-criteria photoelectric smoke detector with thermal detection (135°F fixed temperature) and B510W4" base WSK-HEAT: Wireless Heat, (135°F fixed temperature) and B510W4" base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and 8510W 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Toots USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power-limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput" circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock!key* CELL-MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6' D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4— 351607:B 9/26/2018 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) Fiexput', Honeywell, Overall Dimensions: 12.71" W 15.12" H 3.33 D Two programmable circuits which can be JumpStart. Silent Knight SWIFT-, and System Weight: 15 tbs. programmed individually as: Sensor- are registered Color: Red NAGs: 2.5A @ 27.4VDC per circuit, power-Limited trademarks of Honeywell (with a panel maximum current of 2.5A) International Inc. ENVIRONMENTAL Auxiliary Power Circuits: 2.5A @ 27.4VDC per Hochiki is a registered Operating Temperature: 32°F c 120°F (0°c to circuit, power-limited trademark of Hochiki 49°C) Corporation. Microsoft Humidity: 0 to 93% relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) and Windows' are condensing) configuration for the SLC registered trademarks of Microsoft Corporation. ELECTRICAL WIRING: See the product manual for wiring details This document is not 6700 Primary AC: 120 VAC @60Hz, 1.5A Total intended to be used for installation Accessory Load: 2.5A @ 27.4 VDC power-limited purposes. We try to keep our product Standby Current: 165mA information up-to Alarm Current: 310mA date and accurate. We Battery Charging Capacity: 7 to 35AH cannot cover all specific Battery Size: 7AH max. allowed in control panel appLications or anticipate all requirements. All cabinet. Larger capacity batteries can be housed in specifications are subject RBB accessory cabinet to change without notice. ForTechnical Support, call 8004466444. Honeywell Silent Knight 12 Clintonville Road CT 06472 800-328-0103 Honeywell www.silentknight.com 3516071 B 109/18 SILENT c 2018 Honeywell International Inc. 13 NICI-rr CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0501 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneyweII.com DESIGN: Silent Knight Model 6700, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model 6700 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10"HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: I20VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and ii This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not R. an endorsement or recommendation of the item listed. This listing should not be used to verify correct Ov operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 4 Listing No. 7165-0559:0501 Page 2 of 2 indicating devices. Refer to listee's Installation Instruction Manual for details. TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Honeywell 3 sllENT. KNIGHT SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DN R Series duct detector housings. SK-PHOTO-W FEATURES & BENEFITS New modern profile for Dual LED design Expanded color improved aesthetics provides 3600 viewing options Stable communication angle technique with noise immunity from the panel Built-in functional test switch activated by external magnet Built-in tamper- resistant feature Sealed against back pressure • Remote test feature Low standby current Two-wire SLC connection Optional remote, single- gang LED accessory Optional relay, isolator, and sounder bases Plugs into separate base for ease of installation and maintenance SEMS screws for wiring of the separate base DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document 405-1003, is available at systemsensor.com INSTALLATION The SK-PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "1-taps" or branches are permitted for Style 4 (Class "B") wiring. When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION SK-PHOTO-W: Photoelectric smoke detector, white. SK-PHOTO-R-W: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, white. SK-PHOTO-T-W: Photoelectric smoke detector with thermal sensing, white. INTELLIGENT BASES B300-6: White, standard flanged low-profile mounting base. B300-6-BP: Bulk pack of B300-6, package contains 10. B300-6-IV: Ivory, standard flanged Low-profile mounting base. B501-WHITE: White, standard European flangeless mounting base. UL listed. B501-BL: Black, standard European flangeless mounting base. UL listed. 8501-IV: Ivory, standard European flangeless mounting base. UL listed. B200S-WH: White, Intelligent, programmable sounder base. B200S-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base for retrofit applications. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. 8224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224B1-WH: White, plug-in System Sensor isolator detector base. 8224B1-IV: Ivory, plug-in System Sensor isolator detector base. ACCESSORIES CK300: Color Kit (includes cover and trim ring), white, 10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-Pack. M02-04-01: Detector test magnet. M02-09-00: Telescoping test magnet. RA100Z: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6, white. TR300-IV: Replacement trimring for B300-6-IV, ivory. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL Height: 2.0(51mm) installed in B300-6 base Diameter: 6.2(156mm) installed in B300-6 base 4.1(104 mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Photo: 32°F to 122°F (0°C to 50°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) UL listed Velocity range: Photo/Photo with Thermal: 0 to 4,000 fpm (0 to 20 m/sec) (suitable for installation in ducts) Humidity: 10% to 93% non-condensing Thermal Ratings: Fixed Temperature Set point: 135°F (57°C) ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Operating Current® 24VDC: 2001.jA (one communication every 5 seconds with green LED blink on communication) Maximum Current: 4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). COMPATIBILITY The SK-PHOTO-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panelwith an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S6173 FM approved CSFM: 7272-0559:0523 For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight', System Sensor' and Honeywell' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate alL requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 3516341 Rev 104/18 C 2018 Honeywell International Inc. Honeywell DSILENT KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL tp FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0512 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson©honeywell.com DESIGN: Models lDP-PHOTO-W, IDP-PHOTO-R-W, IDP-PHOTO-T-W, SK-PHOTO-W, SK-PHOTO-R-W, and SK-PHOTO-T-W analog addressable, photoelectric smoke detectors for open area and duct installations. Models IDP-PHOTO-T-W and SK-PHOTO-T-W have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model 0355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0503 02-06-18 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAWD CASTILLO, Program Coordinator Fire Engineering Division Honeywell DSILENT KNIGHT SK-HEAT-W Series Intelligent Thermal (Heat) Detector Honeywell Silent Knight SK-H EAT-W Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 1351F/571C fixed temperature, rate-of-rise and a 190°F/880C fixed high-temperature detectors. These thermal detectors provide effective, intelligent property protection ma variety of applications. SK-HEAT-W FEATURES & BENEFITS Sleek and stylish contemporary design Advanced thermal technology for fast response Fixed temperature model (SK-HEAT-W) factory preset to 135°F (57°C) Rate-of-rise model (SK-HEAT-W-ROR), 15°F (8.3°C) per minute High temperature model(SK-H EAT- W-HT) factory preset to 190°F (88°C) Addressable by device Two-wire SLC connection Visible LEDs 'blink' every time the unit is addressed Built-in tamper- resistant feature 3601-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identification Remote test feature from the panel Built-in functional test switch activated by external magnet Walk test with address display (an address of 121 will blink the detector LED 12- (pause)-1) Low standby current Designed for directsurface or electrical box mounting Sealed against back pressure Plugs into separate base for ease of installation and maintenance SEMS screws for wiring of the separate base Optional remote. single- gang LED accessory APPLICATIONS Use thermal detectors for protection of property. For further information, refer to manual 156-6541, Applications Manual. for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector Mount base (all base types) on an electrical backbox which is at least 1.5' (3.81 cm) deep. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. INTELLIGENT BASES B300-6: White, standard flanged low-profile mounting base. B300-6-BP: Bulk pack of B300-6, package contains 10. B300-6-IV: Ivory, standard flanged low-profile mounting base. B300A-6-IV: Ivory, standard flanged low-profile mounting base. UL listed. B501-WHITE: White, standard European flangeless mounting base. UL listed. B501-BL: Black, standard European flangeless mounting base. UL listed. B501-IV: Ivory, standard European flangeless mounting base. UL listed. B200S-WH: White, Intelligent, programmable sounder base. B200S-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base for retrofit applications. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. ACCESSORIES CK300: Color Kit (includes cover and trim ring), white, 10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black. 10-Pack. M02-04-01: Detector test magnet. M02-09-00: Telescoping test magnet. RA100Z: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6, white. TR300-IV: Replacement trimring for B300-6-IV, ivory.. NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. ORDERING INFORMATION SK-HEAT-W: Thermal heat detector, 135°F fixed, white. SK-HEAT-ROR-W: Thermal heat detector, 135°F rate of rise, white. SK-HEAT-HT-W: Thermal heat detector, 190°F high temp, white. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224B1-WH: White, plug-in System Sensor isolator detector base. B22BI-IV: Ivory, plug-in System Sensor isolator detector base. SK-H EAT-W Series Detector Technical Specifications PHYSICAL Height: 2.0(51mm) installed in 6300-6 base Diameter: 6.2(156mm) installed in B300-6 base 4.1(104mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Heat -Fixed temperature: -4°F to 100°F (-20°C to 38°C) Heat -Rate of Rise (ROR): -4°F to 100°F (-20°C to 38°C) Heat -High Temperature: -4°F to 150°F (-20°C to 66°C) Humidity: 10% to 93% non-condensing Thermal Ratings: Fixed Temperature Set point: 135°F (57°C) Rate-of-Rise Detection: 15°F/mm. (8.30C/mm High Temperature Heat: 190°F (880C)Electrical Ratings ELECTRICAL RATINGS Voltage Range: 15 to 32VDC peak Standby current (max. avg.): 200u4 @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 4.5m4 ® 24 VDC (ON"). COMPATIBILITY The SK-HEAT-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S2101 FM Approved CSFM: 7270-0559:0511 Fora complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight, System Sensor and Honeywell' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 351637 I Rev A 104/18 :c 2018 Honeywell International Inc. Honeywell DSILENT KNIGhT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0559:0511 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson©honeywell.com DESIGN: Models IDP-HEAT-W, IDP-HEAT-HT-W, SK-HEAT-W, SK-HEAT-HT-W (fixed temperature) and IDP-HEAT-ROR-W, SK-HEAT-ROR-W (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models IDP-HEAT-W and SK-HEAT-W (fixed temperature): 135°F. Models IDP-HEAT-HT-W and SK-HEAT-HT-W (fixed temperature): 190°F. Models IDP-HEAT-ROR-W, SK-HEAT-ROR-W (fixed temperature with rate of rise): 135'F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B7IOLP (CSFM#7300-0028: 173); System Sensor bases B510, 132101-P, B300-6, B300-6-IS (CSFM#7300-1653:0109); 132241311, B224RB (CSFM#7300-1653:0126); B200S, 8200SR (CSFM#7300-1653:0213); B200S-LF, B200SR-LF (CSFM#7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. XLF: 7270-0028:0502 02-06-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SK-PULL-SA SK-PULL-DA Honeywell Dsmut",KNIGHT SK-PULL-SA I SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double gang or 4"(10.61 cm) square electrical box. You can also use the optional (System Sensor" PIN BG-TR) trim ring if the station is being semi-flush mounted. FEATURES & BENEFITS Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated testa nd reset lock using lock plate actuator Key matches compatible FACP locks Meets ADA requirement for 5 lbs maximum pull force to active Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4. 1.3 [131) Shell, door, and handle molded from durable LEXANI Reliable analog communications for trouble-free operation Braille text on station handle Rotary address switches for fast installation Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled UL Listed, including UL 38, Standard of Manually Actuated Signaling System CSFM Listed MEA Listed SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete Listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions: 5.5"H x 4"W x 1.45' D (14 x 10.2 x SK-Pull-SA: Single Action Pull Station 3.7cm) SK-PuLl-DA: Dual Action Pull Station Microsoft, Windows, and the Windows Logo are Housing Material: LEXAN polycarbonate resin registered trademarks Bi-CoLored LED: ACCESSORIES or trademarks of Blinking Green: Normal BG-TR: Optional trim ring. Microsoft Corporation. Steady Red: Alarm SB-I/O: Surface backbox, indoor/outdoor. Silent Knight', System Switch: Single pole, single throw (SPST) normally * Unless otherwise noted, specifications apply to Sensor' and Honeywell' open (N/O) switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International, Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage: 15 - 32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current: 350jA Knight fire alarm control panels: installation purposes. We Wire Gauge: Up to I2AWG (3.1 mm2) 6820: Addressable fire alarm control panel try to keep our product information up-to 6820EV5: Addressable fire alarm control panel date and accurate. We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature: 32°F - 120°F (0°C - 6808: Addressable fire alarm control panel applications or anticipate 49°C) 6700: Addressable fire alarm control panel all requirements. All specifications are subject Humidity: 10°/ - 93% non-condensing 5700: Addressable fire alarm control panel to change without notice. 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel For Technical Support, call 800-446-6444. 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight Clintonville Road Honeywell Northford, CT 06472 Doc 3501351 Rev El 11/17 ? Sn..ENT 800-328-0103 C 2017 Honeywell international inc. IJ KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0161 Page 1 of I CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-0028:0199 04-16-09 STi This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftv% operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Honeywell DSiLENT' KNIGHT SK-MINIMON Intelligent Mini Monitor Module The SK-MINIMON is an addressable monitor modules for use with the Honeywell Silent Knight fire alarm control panels (FACPs). The SK- MINI MON acts as an interface to contact devices, such as waterf low switches and pull stations. The SK-MIN I MON supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. INSTALLATION The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. 5K- M IN IM ON FEATURES & BENEFITS Single contact monitor Rotary address SK-Minimon support switches for fast for Class B (Style B) installation contact monitor wiring UL Listed Small and lightweight CSFM Listed size allows for flexible FM Approved mounting options SK-MINIMON Technical Specifications PHYSICAL Dimensions: 2.75" W x 1.3'H x0.5" D Weight: 1.2 oz (37 g) ELECTRICAL Operating Voltage: 15— 32VDC SLC Standby and Alarm Current: 350 iA End-of-Line Resistance: 47K 92 Initiating device circuit wiring resistance: 1,5000 max SLC Loop resistance: 40Q max Wire Length: 6" mm. ENVIRONMENTAL Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10°/c - 93% non-condensing ORDERING INFORMATION SK-MINIMON: Mini monitoring module COMPATIBILITY The SK-MINIMON is compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system For a complete listing of all compliance approvals and certifications, please visit www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight", System Sensor" and Honeywell" are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support. caLl 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 3501331 Rev G 111/17 v 2017 Honeywell International Inc. Honeywell DSILENT" KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM t9 LISTING No. 7300-0559:0155 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywelI.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, 5K -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, IDP-Monitor, lDP-Minimon, IDP-Zone, SK-Monitor, 5K-Minimon, SK-Zone monitor modules, IDP-Control, IDP-Relay, 5K-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDP..RELAYMON..2 *SK..RELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR Mini-Horns The SpectrkerP Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. SPECTFJert The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriters Laboratories Standard UL 464 for fire protective signaling systems. Features 12 and 24V operation High and low volume settings Temporal and non-temporal tones Mounts to single gang back box Compatible with MDL sync module Mechanically and electrically compatible with PA400 series MiniAlertTM sounders Listing for ceiling or wall mounting Agency Listings LISTED S4011 APPROVED 3028007 CS1099 7135-1653:196 SpectrAlert® Advance Mini-Horn Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box. Mini-horn shall be listed to Underwriters Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync'Circuit° Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9W x .45D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: deep single-gang back box (23A" deep) Flush: Standard 4x 4- back box with single gang mud ring, which allows sufficient clearance for conduit entrance. Electrical Specifications InputTerminals 12 to 18AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DCIRNR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 Nominal 12 16-33 16-33 VDC VFWR VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High 72 71 75 74 80 79 temporal 4 Non- Low 70 69 73 72 78 77 temporal tSounder CurrentI Draw lIW1:h'il 8-17.5 Volta 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information IflIis irU11i.i. MHR Mini-Horn, Red MHW Mini-Horn, White "STEM 3825 Ohio Avenue • St. Charles, IL 60174 ©20128ystem5ensor. Product specifications subject to change without notce. Visit ayatemsensor.com SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 foccurrentproductinformadoninud!ng the latest version of this data sheet. AVDS01500 • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0196 Page 1 of 1 CATEGORY: 7135 -- AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson©honeywell.com DESIGN: Models MHR, MHW and APA151 horns. The Model APAI5I is a remote sounder intended to be connected to the alarm indicating circuit of listed duct smoke detectors. All units are for indoor use only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: APAI5I: Regulated 24 VDC Operational 16-33 Volts, 30mA MHR and MHW: Regulated 12V DC/FWR and 24V DC/FWR Operational 8-17.5 and 16-33 Volts, 18mA at 12V and 30mA at 24V Audibility: MHR and MHW Tones 1, 2, 3 & 4 are Public Mode at 24V DC/FWR Tone 3 is Public Mode at 12V DC Tones 1, 2 & 4 are Private Mode at 12 V DC Tones 1, 2, 3 & 4 are Private Mode at 12V FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models MHR and MHW are listed as an audible signal appliance for use with separately listed compatible fire alarm control units. Model APAI5I is listed as an accessory horn for use with separately listed 4-wire conventional duct smoke detectors. (REF: 3240-1653:119) Refer to manufacturer's Installation Manual for details. 03-15-07 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Agency Listings SIGNAUNG USTO FM S4011 (Chimes, horn strobes, horns) APPROVED S3593 (Outdoor and alert strobes) 3023572 * MEA 7300-1653:187 (outdoor strobes) approved 7125-1653:188 (hors strobes, chime strobes) MEA452-05-E 7135-1653:189 (horns, chimes) r SYSTEM $ SENSOR SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40°F to 151°F Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verity proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 3A-inch top and bottom conduit entries and 3.4-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. Outdoor Selectable, Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrA Ion® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from -40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SynceCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 OF (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6L x 4.7"W x 1.3D (142 mm Lx 119 mm x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"Lx 5.1"W x 2.0"D (145 mm Lx 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSO12OI UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) uJuu:r1.mT 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern - dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (rnA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low UL Max. Current Draw (rnA DC Input 132 154 RMS), 2-Wire Horn 16-33 Volts 135 150 80 Strobe, High 177 90 105 Candela Range (135-185 cd) 185 FWR Input 161 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data Horn rIand uHorn rI Output yj 8-17.5 16-33 MII. 24-Volt Nominal 6 A.L... Strobe Output Listed Candela Candela rating at -40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 wuu uunu ...n, ii nviijiai IICuuUu Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High Temporal 82 82 88 88 93 92 100 100 5 Non- Medium Temporal 78 78 85 85 90 90 98 98 6 Non- Low Temporal 75 75 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 Coded Low 75 75 61 81 88 85 96 92 Settings 7, 8, and 9 are not available on 2-wire horn strobe. AVD801201 Wall-Mount Horn Strobes erproof Back Box SpectrAlert Advance Diagrams Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information rnoaei Wall Horn Strobes II*!sIlIs1ff.]i P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WKt 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*I Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HHKT Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P' to model number for plain housing (no FIRE' marking on cover), e.g., P2RK-P. t Add -R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof Outdoor flush mounting plate, WTP and WTPW "Standard cd" refers to strobes that include 15, 15/75,30,75,95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. T"s ç)5j7 3825 Ohio Avenue • St. Charles, IL 60174 020 2 System Sensor. Product specifications subject to change wthout notice. Visit oyoternoensoicom 45 SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product informallon, including the latest version of this date sheet. AVDS0120I • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson©honeywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix 'P° for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ( SYSTEM I $ SENSOR® Indoor Selectable= Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15,30,75,95, 110,135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Strobes and Horn Strobes listed for wall mounting only Horns listed for wall or ceiling use Agency Listings SIGNALING 0 USTED APPROVED S5512 FM approved except 7125-1653:0504 84011 for ALERT models 1135-1653:0503 3057383,3057072 The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS865-05 • 2/22/2016 • Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/e-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuif° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 X 411/16 X 21/e-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/RNR1 Operating Voltage Rang& 8 to 17.5 V (12 V nominal) or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Wall-Mount Dimensions (including lens) 5.6L x 4.7'W x 1.91"D (143 mm Lx 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46" W x 1.91" D (133 mm Lx 88 mm W x 49 mm 0) Horn Dimensions 5.6L x 4.7W x 1.25ff Lx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" D (133 mm Lx 88 mm W x 32 mm D) Full Wave Rectified (RNR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 Cd and 30 cd. AVDS865.05 • 2/2212018 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.lKTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AVD5865.05 • 2/2212018 • Page 3 Horn m— 4.70 cm (11.94cm) tgr (4.85 cm) 1.25" It (3.18 mm) 5.67" (14.4 cm) Strobe, Horn Strobe A0550-OO 1.25" •_______ Cer 32 mm (12.24 cm) - (4.69 cm) F 5.1 !S :I4.9f cm) A0554.01 Wall Surface Mount Back Box SBBRL/SBBWL L-Series Dimensions t91 48.5 nun - 8.46" -. 88 mm I 1.28" —3.57"— —t55, - 58mm us. 32 man (11 Cm) (3.9 CM) 32 min I. 1 "-0 Cm 52r td" I 133.9mm 527" 133.9 mm _________ _ 5.28" C (18.7 cm) 0 0 _ - A0548.00 A0547-00 A0557.00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL L-Series Ordering Information Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Camp 2 fils act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Horns* HRL" Horn, Red HWL* Horn, White HGRL* Compact Horn, Red HGWL* Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. Al) -ALERT models have "ALERT' marking on cover. nHornonly models are listed for wall or ceiling use. 3825 Ohio Avenue • St. Charles, IL 60174 02018 System Sensor. SENSOR Phone: 800-SENSOR2 ' Fax: 630-377-6495 Product specifications subject to Change whtrout notice. VisitsyStemsensnr.Oorn for current product information, including the latest version of this data sheet. www.systemsensor.com AVDS865.05 • 2/22/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneywelI.com DESIGN: System Sensor Indoor 2-wire and *4..wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson©honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt TI4 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct iSv% operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDClfwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 'S