Loading...
HomeMy WebLinkAbout5015 TIERRA DEL ORO ST; ; FPR2019-0025PERMIT REPORT k_lcity of Carlsbad Print Date: 11/09/2023 Job Address: 5015 TIERRA DEL ORO ST, CARLSBAD, CA 92008-4351 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2100201500 Track #: Valuation: $736,145.33 Lot #: Occupancy Group: - Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2019-0025 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 02/21/2019 Issued: 07/08/2019 DEV05114 Finaled Close Out: 05/21/2020 Final Inspection: INSPECTOR: Salcedo, Felix Maldonado, Adalmira Project Title: MOSS RESIDENCE Description: MOSS RESIDENCE -NEW SPRINKLER SYSTEM Applicant: FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELA ZUMAYA 9475 CHESAPEAKE DR 12155 PAINE PL SAN DIEGO, CA 92123-1336 P0 WAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov SYMONS FIRE PROTECTION, INC. 12155 PAINE PLACE POWAY, CA 92064 LICENSE C16-682025 HYDRAULIC CALCULATIONS FOR MOSS RESIDENCE. REMOTE AREA 2 HEAD CALC TYCO LF II CONC/FLAT FILE NUMBER: 18-0471 DATE: 2-15-19 -DESIGN DATA- OCCUPANCY CLASSIFICATION: R3 DENSITY: AREA OF APPLICATION: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED : TOTAL WATER REQUIRED (including hose ) : FLOW AND PRESSURE (@ NODE 5 BOR): SPRINKLER K-FACTOR (ORIFICE SIZE): DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: .05 gpm/256 sq. ft. 512 sq. ft. 2 sprinklers 26.2 gpm 31.2 gpm (5 gpm Hose STREAM) 26.2 gpm @ 22.5 psi 4.9 CHRISTIAN MENDOZA CARLSBAD FIRE. WATER FLOW AVAILABILITY DATA: STATIC : 68 PSI (-10% 61 PSI) RESIDUAL: 67 psi FLOW: 500 gpm WATER DEPARTMENT: CARLSBAD WATER DIST . 1-26-19 CALCULATIONS BY HASS COMPUTER PROGRA M HRS SYSTEMS, INC. ATLANTA, GA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 I5ATE: '2/15/2019 C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW A V A I L . T O T A L R E Q ' D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 61.0 60,0 500.0 61.0 31.2 52.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 52.2 31.2 2 3.0 - - - - 44.0 - - - 3 3.0 - - - - 40.0 - - - 4 9.0 - - - - 29.5 - - 5 13.0 HOSE STREAM 22.5 5.0 6 19.0 - - - - 18.5 - - - 7 19.0 - - - 16.7 - - - 8 19.0 - - - - 15.4 - - - 9 19.0 - - - - 14.9 - - - 10 29.0 - - - - 9.7 - - - 11 29.0 - - - - 10.4 - - - 12 32.0 - - - - 7.7 - - - 13 32.0 K= 4.90 7.2 13.2 14 32.0 - - - - 7.5 - - - 15 32.0 K= 4.90 7.0 13.0 SPRINKLER SYSTEM HYDRAULIC ANALY S I S Page 2 DATE: 2/15/2019 C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.2 0.995 PL 20.00 PF 6.8 1 0.0 SRCE 52.2 (N/A) 12.9 150 FTG TG PE -1.3 2 3.0 0.0 44.0 0.0 0.253 TL 27.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 3.0 0.0 44.0 0.0 4.0 psi, 31.2 gpm 3 3.0 0.0 40.0 0.0 Pipe: 3 31.2 1.101 PL 50.00 PF 7.9 3 3.0 0.0 40.0 0.0 10.5 150 FTG 1.0 PE -2.6 4 9.0 0.0 29.5 0.0 0.155 TL 51.00 PV Pipe: 4 31.2 1.025 PL 5.00 PF 5.3 4 9.0 0.0 29.5 0.0 12.1 150 FTC 19.0 PE -1.7 5 13.0 H.S. 22.5 5.0 0.219 TL 24.00 PV Pipe: 5 26.2 1.101 PL 6.00 PF 1.5 5 13.0 H.S. 22.5 5.0 8.8 150 FTG 7.0 PE -2.6 6 19.0 0.0 18.5 0.0 0.112 TL 13.00 PV Pipe: 6 26.2 1.101 PL 4.00 PF 1.8 6 19.0 0.0 18.5 0.0 8.8 150 FTG 12.0 PE 0.0 7 19.0 0.0 16.7 0.0 0.112 TL 16.00 PV Pipe: 7 17.8 1.101 PL 9.00 PP 1.3 7 19.0 0.0 16.7 0.0 6.0 150 FTG 15.0 PE 0.0 8 19.0 0.0 15.4 0.0 0.055 TL 24.00 PV Pipe: 8 4.7 1.101 PL 67.00 PF 0.4 8 19.0 0.0 15.4 0.0 1.6 150 FTC 28.0 PE 0.0 9 19.0 0.0 14.9 0.0 0.005 TL 95.00 PV Pipe: 9 8.4 1.101 PL 94.00 PF 1.8 7 19.0 0.0 16.7 0.0 2.8 150 FTG 35.0 PE 0.0 9 19.0 0.0 14.9 0.0 0.014 TL 129.00 PV Pipe: 10 13.0 1.101 PL 10.00 PF 0.6 8 19.0 0.0 15.4 00 4.4 150 FTG 10.0 PE -4.3 11 29.0 0.0 10.4 0.0 0.031 TL 20.00 PV Pipe: 11 13.1 1.101 PL 11.00 PF 0.9 9 19.0 0.0 14.9 0.0 4.4 150 FTC 17.0 PE -4.3 10 29.0 0.0 9.7 0.0 0.031 TL 28.00 PV Pipe: 12 5.2 1.101 PL 79.00 PF 0.7 11 29.0 0.0 10.4 0.0 1.8 150 FTG 46.0 PE 0.0 10 29.0 0.0 9.7 0.0 0.006 TL 125.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 2/15/2019 C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 7.8 1.101 PL 68.00 PF 1.7 11 29.0 0.0 10.4 0.0 2.6 150 FTG 71.0 PE -1.3 14 32.0 0.0 7.5 0.0 0.012 TL 139.00 PV Pipe: 14 18.4 1.101 PL 3.00 PF 0.8 10 29.0 0.0 9.7 0.0 6.2 150 FTG 10.0 PE -1.3 12 32.0 0.0 7.7 0.0 0.058 TL 13.00 PV Pipe: 15 13.2 1.101 PL 2.00 PF 0.4 12 32.0 0.0 7.7 0.0 4.4 150 FTG 12.0 PE 0.0 13 32.0 4.9 7.2 13.2 0.031 TL 14.00 PV Pipe: 16 13.0 1.101 PL 2.00 PF 0.4 14 32.0 0.0 7.5 0.0 4.4 150 FTG 12.0 PE 0.0 15 32.0 4.9 7.0 1.3.0 0.031 TL 14.00 PV Pipe: 17 5.2 1.101 PL 11.00 PF 0.2 12 32.0 0.0 7.7 0.0 1.7 150 FTG 25.0 PE 0.0 14 32.0 0.0 7.5 0.0 0.006 TL 36.00 PV NOTES (HASS): Calculations were performed by the HASS 8. 8 D c o m p u t e r p r o g r a m in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provi d e a n a v e r a g e imbalance at each node of 0.001 gpm and a m a x i m u m imbalance at any node of 0.010 gpm. Total pressure at each node is used in ba l a n c i n g t h e s y s t e m . Maximum water velocity is 12.9 ft/sec at p i p e 1 . Items listed in bold print on the cove r s h e e t are automatically transferred from the c a l c u l a t i o n r e p o r t . Available pressure at source node 1 un d e r f u l l f l o w c o n d i t i o n s i s 60.99 psi with a flow of 34.91 gpm. PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 2/15/2019 C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 MD CALC PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyViv GatViv AimChk D P V l v N P T e e 1.025 1.79 4.47 1.79 4.47 5.36 0.89 8.93 1.79 4.47 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Eli Tee RunT Kpig ChkVlv Gate 1.101 1.40 2.50 6.00 1.70 1.00 8.00 0.40 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Eli Tee 45-Eli TeeRun Koupig ChkVlv GatVlv N P T e e 0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYS I S Page 5 DATE: 2/15/2019 C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC WATER SUPPLY ANALYSIS Static: 61.00 psi Resid: 60.00 psi F l o w : 5 0 0 . 0 g p x n 80.0 70.0 60.1) G A U 50?) G E 40.0 LEGEND Available pressure 60.99 psi @ 31.2 gpm Required pressure 52.16 psi @ 31.2 gpm Source Supply Curve System Demand Curve P R 30.0 E 20.0 S U 10.0 R E mm p -14 .7 10(150 200 250 300 350 400 450 500 FLOW (GPM) Dte: (1) Dashed Lines indicate ext r a p o l a t e d v a l u e s f r o m T e s t R e s u l t s SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 2/15/2019 C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC WATER SUPPLY CURVE 72+ 66+ 0\\\\\\\\\\\\\\\\\ 60+ <-60.0 psi @ 500 gpxn Flow Test Point 54+ x P 48+ RI El S 42+ UI RI Ef 36+ 24+ 18+ 12+ LEGEND I U I X = Required Water Supply 52.16 psi 8 31.2 gpin U 6+ I 0 = Available Water Supply 60.99 psi @ 31.2 gpm 'I II +------+ --------+--------+--- - - - - - - + - - - - - - - - - - - + 200 300 400 500 600 700 800 900 1000 FLOW (GPM) tqco Fire Protection Products Worldwide www.tyco-flre.com Contacts RAPID RESPONSE Series LFII Residential 49 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are decorative, fast response, fusible solder sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers (1Y3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 130 wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 The Series LFII Residential Concealed Pendant Sprinklers (TY3596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFil Residential Con- cealed Pendent Sprinklers (1Y3596) are shipped with a Disposable Pro- tective Cap. The Protective Cap Is temporarily removed for Installation, and then it can be replaced to help protect the sprinkler while the ceiling Is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, It has been determined that the number of design sprinklers (hydraulic design area) for the Series LFll Residential Concealed Pendant Sprinklers (TY3596) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to not having to increase-the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. FEBRUARY 2015 NOTICEI The Series LFII ResidentIal Concealed Pendent Sprinklers (TY3596) described herein must be installed and main- taThed in compliance with this docu- ment and with the applicable standards of the National Fire Protection Associa- tion INFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3596 TFP442 TFP442 Page 2 of 6 BODY (1/2' NFl) ----.•...•..._-••.. CAP SADDLE SUPPORT CUP WITH ROLL FORMED THREADS GUIDE PIN GUIDE PIN HOUSING DEFLECTOR THREAD INTO SUPPORT CUP UNTIL MOUN11NG SURFACE IS FLUSH WITH CEILING SOLDER TAB ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) / SOLDER LINK H H ELEMENT I I II I I II I I II I I I I 'I DEFLECTOR (OPERATED POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY RETAINER I WITH THREAD ii - DIMPLES COMPRESSION SCREW SPRINKLER WRENCHING AREA SEALING ASSEMBLY EJECTION SPRING COVER PLATE LEVER WRENCH RECESS 0 t PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH 2-1/2' DIA. SPRINKLER- (63,5 mm] 1/2 (12,7 mm) FACE OF SUPPORT CUP 1121 \ THREADED SPRINKLER \ ASSEMBLY NPT ADJUSTMENT FUTING OPERATED I 'Ik / I .----- V , "SPRINKLER J 11 PLATE I- (47.6 mm RETAINER Jf (3,2 mm) I 1-7/8'±1/4' COVER I 1/8' GAP t6,4 mm) 311f61 J \ I 7/88 (22.2 COVER- SPRINKLER- MOUNTING RETAINER SUPPORT CUP SURFACE __________________ __ ASSEMBLY ASSEMBLY (4,8 mm \1 1-1,8' (28,6 mm) 3-3/16' DIA. DI SPOSABLE DEFLECTOR IN (81.0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEA L E D P E N D E N T S P R I N K L E R ( T Y 3 5 9 6 ) INSTALLATION DIMENSIONS/PROTECTIVE CAP/AC T I V A T E D D E F L E C T O R TFP442 Page 3 of 6 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFll Residential Concealed Pendent Sprinklers are only Listed with the Series LFII Con- cealed Cover Plates having a factory-ap- plied finish. Cover Plates can be ordered by following the instructions in the Ordering Procedure section. Maximum Working Pressure 175 psi (12,1 bar) Discharge Cpfflcient K=4.9 gpm/psl (70,6 1pm1bar112) Temperature Rating 160°F (71°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 112 Inch (12,7 mm) Finishes Refer to Ordering Procedure section. Physical Characteristics Body.........................Brass Cap.........................Bronze Saddle .......................Brass Sealing Assembly ....... Beryllium Nickel w/TEFLON Soldered Link Halves............Nickel Lever........................Bronze Compression Screw.............Brass Deflector ................... Copper or Brass Guide Pin Housing.............Bronze Guide Pins .............Stainless Steel or Bronze Support Cup ...................Steel Cover Plate ..................Copper Retainer......................Brass Cover Plate Ejection Spring..........Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Support Cup at three points, tails away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin-kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprinkler to activate and flow water. Design Criteria TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (1Y3596) are UL and C-UL Usted for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cr1- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Usting, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given In Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems Is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: the flow rates given in Tables A and B as a function of temperature rat- ing and the maximum allowable cov- erage area a minimum discharge of 0.1 gpm/ft.2 over the design area comprised of the four (4) most hydraulically demanding sprinklers for actual coverage areas protected by the four (4) sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems Is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFll Residen- tial Concealed Pendent Sprinklers (1Y3596) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds forthe most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational SensItivity The sprinklers are to be installed rela-tive to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFll must not be used In applications where the air pres- sure above the ceiling Is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure2 ' Coverage Max imum Maximum Spacing Ordinary Temp. Rating Minimum Area 160°F (71°C) Ft x Ft Ft. (m) Deflector to Installation Spacing Flow Pressure (mx m) Ceiling Type Ft. gpm psi (m) (1pm) (bar) 12 X 12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D Concealed 16x16 16 13 7.0 (4,9x4,9) (4,9) (49.2) (0148) 13R, or 13. Installed in (2,4) 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64.3) (0,83) 7/8to1-1/8 inches below 20x20 20 20 16.7 bottom of (6,1) (75,7) (1,15) beam Notser For coverage area dimensions less than or between than Indicated. u s e t h e m i n i m u m r e q u i r e d S o w f o r t h e r , e x t h i g h est coverage area for which hydraulic deaign whavilai are stated. Requirement Is based on minimum flow in gem Opm) from each aprinlder. The associated resid u a l p r e e a u r e e a r e c a l c u l a t e d u s i n g the nominal K-factor. Refella Hydraulic Design under the D e s i g n C r i t e r i a s e c t i o n . For NFPA 13 residential applications, the greater 010.1 gprnflL' over the design area or the 110w In accordance with the c r i t e r i a I n this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLA T P L A T E C O N C E A L E D P E N D E N T S P R I N K L E R ( T Y 3 5 9 6 ) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN C R I T E R I A DRY PIPE SYSTEM Minimum Flow and Residual Pressure 2-2 Maximum a Covere Maximum Spacing Ordinary Temp. Rating Minimum Area Ft. x Ft . Ft. 160°F (71°C) Deflector to Installation Spacing Flow Pressure (mx m) (m) Ceiling Type Ft. gpm psi (m) (1pm) (bar) 12 X 12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed gs per NFPA Calling or Concealed 8 (2,4) 16 IC 16 (4,9x4,9) 16 (4,9) 15 (56,8) (0,65) 13R, or 13. Installed in 18x18 18 18 13.5 beam (5,5x5,5) (515) (6811) (0193) 7/8to1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam Notes: I. For coverage area dimensions less than or between those Indi c a t e d , u s e t h e m i n i m u m r e q u i r e d f l o w f o r t h e n e x t highest coverage area for which hydraulic design crIterIa are stated. 2. Requirement Is based on minimum 110w In gpm flpm) from each sprinider. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. 8. For NFPA 13 residential applications, the greater 010.1 gpmflt' over the design area or the flow In accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFI1 RESIDENTIAL 4. 9 K - F A C T O R F L A T P L A T E C O N C E A L E D P E N D E N T ( T Y 3 5 9 6 ) NFPA 130, 13R, AND 13 HYDRAULIC DESIGN C R I T E R I A TFP442 Page 5 of 6 Installation TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (I.e., do not apply pressure to the fusible Link Assembly). A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lbs.-ft. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler Inlet with consequent leakage or Impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment In the Cover Plate I Retainer Assembly by under- or over-tightening the Sprinkler. Read- just the position of the sprinkler fitting to suit Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler / Support Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step 5. After the ceiling has been completed with the 2-1/2 inch (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Pro- tective Cap, and verify that the Deflec- tor moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step S. Screw on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that It lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance TYCO RAPID RESPONSE Series LFll Residential Concealed Pendent Sprin- klers (1Y3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper opera- tion of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, If necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), In addition to the standards of any other authorities having jurisdiction. Contact the Install- ing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster, otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP442 Page 6 of 6 Limited Warranty For warranty terms and conditions, visit www.tycotire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFll (TY3596) 4.9K Residential Concealed Pendent Sprin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assemblies Specify: Cover Plate Assembly with (specify) finish for the Series LFIl (TY359 4.9K Residential Concealed Pendent Sprinkler, P/N (specify): ivory (RAL1015) ...........P/N 56-202-0435 Beige AL1001) ........... P/N 56-202-2-135 Pure White * (RAL9010) .....P/N 56-202-3435 Signal White ** (RAL9003) ... P/N 56-202-4435 Grey White (RAL9002) ...... P/N 56-202-5-135 Brown (RAL.8028) .......... P/N 56-202-6-135 Black (RAL9005) ..........P/N 56-202-7-135 Brushed Brass ............ P/N 56-202-8435 Brushed Chrome ..........P/N 56-202-9435 Custom Paint ............. P/N 56-202-X-135 Eastern llemlspiere sales only PrevIously known as Bilght White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-2154162-0700 Copyright 02015 Tyco Fire Products, I.P. MI rights reserved. TEFLON lsb-ademwlc of The DuPont Corporation. tqco Ffre Protection Products Worldwide wco-fire.com Contacts RAPID RESPONSE Series LFII Residential 49 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangi- ble bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch 02,7 mm) of total adjustment from the flush ceiling position. The IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com-ponents. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFll Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, It has been determined that the number of design sprinklers (hydraulic design are for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi- dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. NOTICE The Series LFII Residential Pendent and Recessed Pendent Sprinklers (Y2234) described herein must be Installed and maintained in compliance with this document and the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having Jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. MARCH 2015 Sprinkler Identification Number (SIN) 1V2234 Technical Data Approvals UL Listed (for use with wet pipe and dry pipe sys- tems) C-UL Listed (for use only with wet pipe systems) Certified to all requirements of NSF/ANSI 61 (Refer to the Design Criteria section fords- tails on these approvals.) Maximum Working Pressure 175 psi 02,1 bar) Discharge Coefficient K=4.9 gpm/3si112 (70,6 Ipm/bar'/2) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White, Signal White, or Chrome Plated Physical Characteristics Frame........................Brass Button ......................Copper Sealing Assembly......Beryllium Nickel w1rEFLON Bulb (3 mm)...................Glass Compression Screw............Bronze Deflector .....................Bronze TFP400 TFP400 Page 2 of 6 7/16' (11.1 mm) 1/2' ESCUTCHEON Components: 2-7/8' () NOMINAL NPT PLATE SEATING 1 - Frame MAKE-IN SURFACE (73,0 mm) 2 - Button 3 - Sealing Assembly 1 4 - Bulb 5 - Compression 2 Screw 2-1/4' (/1 6 - Deflector* : (57,2 mm) iiiii!! 1.5/8' (41,3 mm) WRENCH STYLE 20 RECESSED 5 FLATS *Temperature -. ESCUTCHEON rating is Indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLER S ( T Y 2 2 3 4 ) - 2-7/8' DIA. 7/16±1/8' (73,0 mm) 1/2' (12,7 mm) (11,1*3,2mm) 2-1/4' DIA. I 1/4' (6,4 mm) FACE OF mm) 21 SPRINKLER r-57'2 MOUNTING FITTING f - PLATE - MOUNTING SURFACE m) _ 2(3 1Y' 9 mm) CLOSURE 1-1/8' (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT S P R I N K L E R Design Criteria The TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers are UL and C-UL Listed for Installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. tWRENCH RECESS (END 'A' USED FOR TY2234) FIGURE 3 V/-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 6 t PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH System Typos Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. TFP400 Page 3 of 6 Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 130 or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 130 or NFPA 13R. The number of "design sprinklers specified in NFPA 130 and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design spnnklerê is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design aree comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems Is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (TY2234) In dry pipe sprin- kler systems, the time for water deliv- ery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located In accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 14/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically cal- culated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be Installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there Is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 Inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min imum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment In an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFii Residential Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions: Step I Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFli Residential Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following Instructions: Step A. Install recessed pendant sprin- klers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been Installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2113) Maximum Coveraee Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C) Minimum Area Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (mxm) gpm ps i gpm i (m) I/min) (bar) (I/mm) 12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/410 4 Inches 14x14 13 7.0 13 7.0 (4,3x4,3) (49,2) (0,48) (49,2) (0,48) Beamed Ceilings per Recessed using Style 20 Escutcheon or 8 16 x 16 13 7.0 13 7.0 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18x18 17 12.0 17 12.0 (5,5x5,5) (64,3) (0.83) (64,3) (0,83) 1-1/4to1-3/4 inches below bottom of 20x20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1.15) (75,7) (1,15) beam. Notes: For coverage area dimensions less than or between those Indicated, use the minimum required flow for the next highest coverage area for which hydraulic design c,ftada are stated. Rerement Is based on minimum flow in gpm (1pm) from each epilnider. The a s s o c i a t e d r e s i d u a l p r e s s u r e s a r e c a l c u l a t e d u e k l g t h e n o m i n a l K-factor. Refer to Hydraulic Design under the Design Cittedaeecticn. For NFPA 13 residential applications, the greater 010.1 gpmMt2 over the design ares or the flow In accordance with the ctfteda in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENTAND RECESSED PENDENT SPRINK L E R S (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum ______________________ Coveraae Ordinary Temperature Rating Intermediate Temperature Rating Area () 155°F (68°C) 175°F (79°C) Minimum Ft. x Ft. IDeflector to Installation Spacing (mxm) Flow Pressure Flow Pressure Ceiling Type pm psi gpm Al(llmJn) (bar) (I/mm) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4104 Inches 14 X 14 14 8.2 14 8.2 (4,3 x 4,3) (53,0) (0,57) (53,0) (0,57) Beamed Recessed using Style 20 Escutcheon or 8 16 x 16 15 9.4 15 9.4 (4,9 x 4,9) (5618) (0,65) (56,8) (0,65)CNFPA eIl ings 1 per3D or 13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18 x 18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 21 18.4 21 18.4 Al x 6,1) (79,5) (1,27) (79,5) (1,27) beam. Notes: For coverage area dimensions less than or between those Indicated, use the minimum req u i r e d f l o w f o r t h e n e x t h i g h e s t c o v e r a g e a r e a f o r w h i c h h y d r a u l i c d e s i g n criteria are stated. Requirement Is based on minimum flow in gpm (1pm) from each spitnider. The asso c i a t e d r e s i d u a l p r e s s u r e s a r e c a l c u l a t e d u s i n g t h e n o m i n a l I(-factor. Refer to Hydraulic Design under the Design Ciltefla section. For NFPA 13 residential applications, the greater of 0.1 gprn/fL2 overthe design area or the flow In accordance with the criteria In this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4,9K PENDENTAND RECESSED PENDENT SPRINK L E R S ( T Y 2 2 3 4 ) - - NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 5 of 6 Care and Maintenance TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that It controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster, otherwise, non- operation In the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but. have not operated, should be replaced If they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices In compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), In addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-flre.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFll 4.9K Residential Pendent Sprinkler (TY2234), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68C) Natural Brass..............P/N 51-2014-155 Pure White (RAt. 9010)° ......P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4455 Chrome Plated ............. P/N 51-201-9455 175°F (79°C) Natural Brass .............. PIN 51-201-1-175 Pure White (RAt. 9010)° ......P/N 51-201-3475 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated ............. PIN 51-201-9-175 Eastern Hemisphere sales only Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TPP77O. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright 02015 Tyco Fire Products, I.P. All rights reserved. tqco TEF wlc LON Is of the DuPont Corporation. Ffr. Protection Products Page 1 N41KjW4j 0 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K56) The Viking Corporation, 210 N Industrial Park Dr i v e , H a s t i n g s M I 4 9 0 5 8 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsviklngco r p . c o DESCRIPTION The Viking Microfasts Quick Response Pendent Spri n k l e r V K 3 0 2 I s a s m a l l thermosensitive glass bulb spray sprinkler availa b l e w i t h v a r i o u s f i n i s h e s and temperature ratings to meet design requireme n t s . T h e s p e c i a l P o l y e s t e r , Poiytetrafiuoroethelyne (PTFE), and Electroless Nickel P T F E ( E N T ) c o a t i n g s can be used in decorative applications where colors a r e d e s i r e d . I n a d d i t i o n , these coatings have been investigated for installatio n i n c o r r o s i v e a t m o s p h e r e s and are listed/approved as corrosion resistant as indi c a t e d i n t h e A p p r o v a l Charts. (Note: FM Global approves ENT finish as c o r r o s i o n r e s i s t a n t . F M Global has no approval classification for PTFE and P o l y e s t e r c o a t i n g s a s c o r r o - sion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNlV FM Approved: Class Series 2000 VdS Approved: Certificates G414009 and G414010 LPCB Approved CE CE Certified: Standard EN 12259-I, EC-certificate of co n f o r m i t y 0 8 3 2 - C P D - 2 0 0 1 CCCF Approved: Approved by the China Certification C e n t e r f o r F i r e P r o d u c t s ( C C C F ) Refer to Approval Chart I and Design Criteria cULus L i s t i n g r e q u i r e m e n t s , a n d r e f e r t o A p p r o v a l C h a r t 2 a n d D e s i g n C r i t e r i E for FM Approval requirements that must be followed. Viking Technical Data may be found on The Viking Corporation's Web site at Specifications: http:llwww.vlkinggroupinc.com. Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure The Web site may include a more recent Factory tested hydrostatically to 500 psi (34.5 bar) edition of this Technical Data Page. Thread size: 1/2 NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric') Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: 2-1/4 (58 mm) *cULus Listing, FM Approval, and NFPA 13 Installs require a minimu m o f 7 p s i ( 0 . 5 b a r ) . T h e m i n i m u m o p e r a t i n g p r e s s u r e f o r L P C B a n d C E Approvals ONLY 185 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper U N S - C 1 9 5 0 0 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated o n b o t h s i d e s w i t h P T F E T a p e Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11 000 and S t a i n l e s s S t e e l U N S - S 3 0 4 0 0 For PTFE Coated Sprinklers: Belleville Spring-Expose d , S c r e w - N i c k e l P l a t e d , P i p C a p - P T F E C o a t e d For Polyester Coated Sorinklers: Belleville Spring-Expose d For ENT Coated Sorinklers: Belleville Spring-Exposed, S c r e w a n d P l p c a p - ENT plated. Ordering Information: (Also refer to the current Vikin g p r i c e l i s t . ) Order Quick Response Pendent Sprinklers by first add i n g t h e a p p r o p r i a t e s u f f i x f o r t h e s p r i n k l e r f i n i s h a n d t h e n t h e a p p r o p r i a t e suffix for the temperature rating to the sprinkler base part n u m b e r . Finish Suffix: Brass = A, Chrome = F, White Polyester = M - M , B l a c k P o l y e s t e r = M - / B , B l a c k P T F E = N , a n d E N T = J N Temperature Suffix: 135 OF (68 °C) = A, 155 OF (68 °C) = B , 1 7 5 O F ( 7 9 ° C ) = D , 2 0 0 O F ( 9 3 ° C ) = E , 2 8 6 O F ( 1 4 1 ° C ) = G For example, sprinkler VK302 with a Brass finish and a 15 5 O F ( 6 8 ° C ) t e m p e r a t u r e r a t i n g = P a r t N o . 1 2 9 7 9 A B Form No. F033314 Rev 15.1 (Added CCCF Approval) TECHNICAL DATA Protective Sprinkler Clip Wrench Flat Protective Sprinkler Cap Page 2 N41KjW4j 0 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial P a r k D r i v e , H a s t i n g s M I 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikin g c o r p . c c Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/13 (available s i n c e 2 0 0 0 ) . Wrench for Recessed Pendant Sprinklers: Part No. 1 6 0 3 6 W / B ( a v a i l a b l e s i n c e 2 0 1 1 ) Optional Protective Sprinkler Cap Remover/Escutcheon Install e r T o o l * P a r t No. 15915 (available since 2010) **A W ratchet is required (not available from Viking). Allows use from the floor by attaching a length off diamete r C P V C t u b i n g t o t h e t o o l . I d e a l f o r s p r i n k l e r c a b i n e t s . R e f e r t o B u l l e t i n F 0 5 1 8 0 ; Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available sin c e 1971) Twelve-head capacity: Part No. 01725A (available si n c e 1 9 7 1 ) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in th e g l a s s b u l b e x p a n d s , c a u s i n g t h e g l a s s t o s h a t t e r , r e l e a s i n g t h e p i p c a p a n sealing spring assembly. Water flowing through th e s p r i n k l e r o r i f i c e s t r i k e s t h e s p r i n k l e r d e f l e c t o r , f o r m i n g a u n i f o r m s p r a y p a t t e r to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Main t e n a n c e r e q u i r e m e n t s . AVAILABILITY The Viking Microfasts Quick Response Pendent S p r i n k l e r V K 3 0 2 i s a v a i l a b l e t h r o u g h a n e t w o r k of domestic and international dis tributors. See The Viking Corporation web site for t h e c l o s e s t d i s t r i b u t o r o r c o n t a c t T h e V i k i n g C o r p o r a t i o n . GUARANTEE For details of warranty, refer to Viking's current list pric e s c h e d u l e o r c o n t a c t V i k i n g d i r e c t l y . ME 0 Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 Rev 15.1 Page 3 C NlKjw4j® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, H a s t i n g s M l 4 9 0 5 8 Telephone: 269-945-9501 Technical Services: 877- 3 8 4 - 5 4 6 4 F a x : 2 6 9 - 8 1 8 - 1 6 8 0 E m a i l : t e c h s v c s @ v i k i n g c o r p . c o TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 OF (57 °C) 100 OF (38 °C) ' Orange Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Po l y e s t e r , B l a c k P T F E , a n d E N T Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all t e m p e r a t u r e r a t i n g s e x c e p t 1 3 5 OF (57 °C) Footnotes The sprinkler temperature rating Is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sp r i n k l e r l o c a t i o n , a n d o t h e r r e q u i r e m e n t s o f t h e A u t h o r i t y H a v i n g J u r i s d i c t i o n . Refer to specific installation standards. 3 The corrosIon-resistant coatings have passed the standard corrosion test r e q u i r e d b y t h e a p p r o v i n g a g e n c i e s I n d i c a t e d i n t h e A p p r o v a l C h a r t s . T h e s e tests cannot and do not represent all possible corrosive environments. P r i o r t o i n s t a l l a t i o n , v e r i f y t h r o u g h t h e e n d - u s e r t h a t t h e c o a t i n g s a r e c o m - patible with or suitable for the proposed environment For automatic s p r i n k l e r s , t h e c o a t i n g s I n d i c a t e d a r e a p p l i e d t o t h e e x p o s e d e x t e r i o r s u r f a c e s only. Note that the spring Is exposed on sprinklers with Polyester, P T F E , a n d E N T c o a t i n g s . For ENT coated automatic sprinklers, the waterway is coated Sprinkler wrench 11 for recessed pe sprinklers -- A 1/2" ratchet Is (not available fron Carefully slide the wrench sideways around the protective cap, ensuring engagement wltP -01111111— the sprinkler wrench flats Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers Form No. F033314 Rev 15.1 Page 401 NIKING® MICROFASTO QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hasting s M l 49058 Telephone: 269-9454501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.co, I Base Thread Sprinkler Slz Nominal Overall Listings and Approvals' Part SIN K.Factor Length (Refer also to Design Criteria.) style Number' U.S. I metrIc' Inches mm cULus4 J VdS I LPCB I CJE7 I 12979 VK302 Pendent 1/2' 15mm 5.6 80.6 2-1/4 58 Al AIZ, BIV, D2. CZ X AIZ, SlY DIZ. CIV — D3Z - E - Product :rn1 Availability (ContactViking Office) 06662B VK302 Pendent 1/2 15mm 5.6 80.6 2-1/4 58 AIZ, B1Y. D2, C2X I — I — I — I — - 18021 VK302 Pendant 1/2' 15 mm 1 5.6 80.6 2-1/4 58 AIX, B1Y Al I AIX, BIY I DIX, CIV' I DIX, CIV' — Approved Temperature Ratings Approved Finishes Approved Escutcheons A -135 'F (57 'C), 155 'F (68 'C), 175 'F I - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 'C), 200 'F (93 'C). 286 'F (141 'C) Polyester", Black Polyes- Viking Micromatic Model E-I Recessed Escutcheon B -135 'F (57 'C). 155 'F (68 'C), 175 'F te,'.' V-Standard surface-mounted escutcheon or the (79 'C), and 200 'F (93 'C) 2- ENT' Viking Microfast Model F-I Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 'F (68 'C). 175 'F (79 'C), and 3-Chrome matic' Model E-1, E-2, or E-3 Recessed Escutcheon 200 'F (93 'C) 2- Standard surface-mounted escutcheon or the D -155 'F (68 'C). 175 'F (79 'C), 200 'F Viking Microfast' Model F-I Adjustable Escutcheon (93'C),286'F (141 'C) 1 Footnotes tBase part number shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor measurement shown Is when pressure Is measured in Bar. When pressure is measured in kPe, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 'Listed by Underwriters Laboratories Inc. for use In the U.S. and Canada. 'cULus Listed as corrosion-resistant 'Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-I. EC-certificate of conformity 0832-CPD-2001. 'CE Certified, Standard EN 12259-1, EC-certlficates of conformity 0832-CPD-2001 and 0832-CPD-2003. 'MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-I 008. cLJLus Listing Recuirements: The Viking Microfast' Quick Response Pendent Sprinkler VK302 i s c U L u s L i s t e d a s i n d i c a t e d I n t h e A p p r o v a l C h a r t f o r i n s t a l l a t i o n in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. 'The sprinkler installation rules contained in NFPA 13 for stan d a r d s p r a y p e n d e n t s p r i n k l e r s m u s t b e f o l l o w e d . IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, Installation, and maintenance inform a t i o n . V i k i n g s p r i n k l e r s a r e t o b e i n s t a l l e d i n a c c o r - dance with the latest edition of Viking technical data, the ap p r o p r i a t e s t a n d a r d s o f N F P A , L P C B , A P S A D , V d S or other similar organizations, and also with the provisions of g o v e r n m e n t a l c o d e s , o r d i n a n c e s , a n d s t a n d a r d s , whenever applicable. Form No. F_033314 Rev 15.1 Page 5 N41KJW4J 8 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hasti n g s M I 4 9 0 5 8 Telephone: 269-9454501 Technical Services: 877-3844464 Fax: 2694184680 Email: techsvcsviklngcorp.coi Base Pad SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' Style ii1• BSP U.S. metrIc2 Inches mm (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2' I 15mm 5.6 80.6 2-1/4 58 AIZ, Bly, 02X, C2 !L.1t1' I:fYM!'l Limited Availability (Contact Local Viking Office) 06662B VK302 Pendant 1/2' 15 mm 5.6 80.6 2-1/4 58 AIZ, BIY, D2X, C2 18021 VK302 Pendent 1/2' 1 15 mm 5.6 80.6 2-1/4 1 58 AIZ, BIY Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A - 135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), 200 'F Viking Micromatict Model E-1 Recessed (93 'C), 286 'F (141 'C) Approved Finishes Escutcheon B - 135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), and I -Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 'F (93 'C) and Black Polyester' Viking Microfast' Model F-I Adjustable Escutcheon, C - 155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C), 286 2- EN15 or recessed with the Viking Micromatic' Model E-1 'F (141 'C) or E-2 Recessed Escutcheon D - 155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C) Z - Standard surface-mounted escutcheon or the Viking Microfast" Model F-I Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking' s c u r r e n t p r i c e s c h e d u l e . 2 Metric k-factor measurement shown Is when pressure is measured I n B a r . W h e n p r e s s u r e I s m e a s u r e d I n k P a , d i v i d e t h e m e t r i c K - f a c t o r s h o w n b y 10.0. 'This table shows the FM Approvals available at the time of printing. O t h e r a p p r o v a l s m a y b e I n p r o c e s s . 4 0ther colors are available on request with the same Approvals as the st a n d a r d c o l o r s . 'FM approved as corrosion resistant. FM Anoroval ReeuIrements The Viking Microfast' Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-stora9e upright and pende n t sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). F M G l o b a l L o s s P r e v e n t i o n D a t a S h e e t s c o n t a i n g u i d e l i n e s r e l a t i n g t o , b u t not limited to: minimum water supply requirements, hydrauli c d e s i g n , c e i l i n g s l o p e a n d o b s t r u c t i o n s , m i n i m u m a n d m a x i m u m a l l o w a b l e spacing, and deflector distance below the ceiling. NOTE: The FM installation auldeilnes may differ from cULus an d / o r N F P A c r i t e r i a . IMPORTANT: Always refer to Bulletin Form No. F_09169 9 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance I n f o r m a t i o n . V i k i n g s p r i n k l e r s a r e t o b e I n s t a l l e d i n a c - cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also wit h t h e p r o v i s i o n s o f g o v e r n m e n t a l c o d e s , o r d i n a n c e s , a n d standards, whenever applicable. Form No. F_033314 Rev 15.1 Page 6 N41KJW4j® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hasti n g s M l 4 9 0 5 8 Telephone: 269-945-9501 Technical Services: 877-384- 5 4 6 4 F a x : 2 6 9 4 1 8 - 1 6 8 0 E m a i l : t e c h s v c s @ v i k i n g c o r p . c o 112" (15 mm) NPT. 2-114" (57 (TIlT - ' M f 1-3/4" (44.5 mm) Installed with a standard 1/8" surface-mounted escutcheon Ceiling Opening Size: 2-511611(58.7 mm) minimum 2-112" (63.5 mm) maximum 2-118" f(54mm) 2" (38 mm) (51 mm) Mm. Installed with a Microfast Note: At maximum, adapter I Model F-I Adjustable exposed 112" (12.7 mm) Iron Escutcheon fees of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: It 2-546" (58.7 mm) minimum IN 2.1/2" (63.5 mm) maximum 2418" -2-118" - 94 (54 i 1418" 141811 1-31411 (44.5 mm) (28.6 mm) (51 Min) (28.6 mm)Max. Max. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed E s c u t c h e o n s Form No. F_033314 Rev 15.1 (Added CCCF Approval)