HomeMy WebLinkAbout5015 TIERRA DEL ORO ST; ; FPR2019-0025PERMIT REPORT k_lcity of
Carlsbad
Print Date: 11/09/2023
Job Address: 5015 TIERRA DEL ORO ST, CARLSBAD, CA 92008-4351
Permit Type: FIRE-Construction Residential Work Class:
Parcel #: 2100201500 Track #:
Valuation: $736,145.33 Lot #:
Occupancy Group: - Project #:
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #:
Plan Check #:
Permit No: FPR2019-0025
Status: Closed - Finaled
Single Family Fire Sprinkl
Applied: 02/21/2019
Issued: 07/08/2019
DEV05114 Finaled Close Out: 05/21/2020
Final Inspection:
INSPECTOR: Salcedo, Felix
Maldonado, Adalmira
Project Title: MOSS RESIDENCE
Description: MOSS RESIDENCE -NEW SPRINKLER SYSTEM
Applicant: FPContractor:
SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC
ANGELA ZUMAYA 9475 CHESAPEAKE DR
12155 PAINE PL SAN DIEGO, CA 92123-1336
P0 WAY, CA 92064-7154 (619) 588-6364
(619) 588-6364
FEE AMOUNT
FIRE NFPA 13D Single Family System (Insp/Bldg) $125.00
FIRE NFPA 13D Single Family System (Plan Review) $246.00
Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov
SYMONS FIRE PROTECTION, INC.
12155 PAINE PLACE
POWAY, CA 92064
LICENSE C16-682025
HYDRAULIC CALCULATIONS
FOR
MOSS RESIDENCE.
REMOTE AREA 2 HEAD CALC
TYCO LF II CONC/FLAT
FILE NUMBER: 18-0471
DATE: 2-15-19
-DESIGN DATA-
OCCUPANCY CLASSIFICATION:
R3
DENSITY:
AREA OF APPLICATION:
NUMBER OF SPRINKLERS CALCULATED:
TOTAL SPRINKLER WATER FLOW REQUIRED
:
TOTAL WATER REQUIRED (including hose
)
:
FLOW AND PRESSURE (@ NODE 5 BOR):
SPRINKLER K-FACTOR (ORIFICE SIZE):
DESIGN/LAYOUT BY:
AUTHORITY HAVING JURISDICTION:
.05 gpm/256 sq. ft.
512 sq. ft.
2 sprinklers
26.2 gpm
31.2 gpm
(5 gpm Hose STREAM)
26.2 gpm @ 22.5 psi
4.9
CHRISTIAN MENDOZA
CARLSBAD FIRE.
WATER FLOW AVAILABILITY DATA: STATIC
:
68 PSI (-10% 61 PSI)
RESIDUAL: 67 psi
FLOW: 500 gpm WATER DEPARTMENT: CARLSBAD WATER DIST
.
1-26-19
CALCULATIONS BY HASS COMPUTER PROGRA
M
HRS SYSTEMS, INC.
ATLANTA, GA
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 1 I5ATE: '2/15/2019
C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC
WATER SUPPLY DATA
SOURCE STATIC RESID. FLOW
A
V
A
I
L
.
T
O
T
A
L
R
E
Q
'
D
NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI)
1 61.0 60,0 500.0 61.0 31.2 52.2
AGGREGATE FLOW ANALYSIS:
TOTAL FLOW AT SOURCE 31.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE
0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM
NODE ANALYSIS DATA
NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM)
1 0.0 SOURCE 52.2 31.2 2 3.0 - - - - 44.0 - - - 3 3.0 - - - - 40.0 - - - 4 9.0 - - - - 29.5 - - 5 13.0 HOSE STREAM 22.5 5.0 6 19.0 - - - - 18.5 - - - 7 19.0
- - - 16.7 - - - 8 19.0 - - - - 15.4 - - - 9 19.0
- - - - 14.9 - - - 10 29.0 - - - - 9.7 - - - 11 29.0 - - - - 10.4 - - - 12 32.0 - - - - 7.7 - - - 13 32.0 K= 4.90 7.2 13.2 14 32.0 - - - - 7.5 - - - 15 32.0 K= 4.90 7.0 13.0
SPRINKLER SYSTEM HYDRAULIC ANALY
S
I
S
Page 2 DATE: 2/15/2019
C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC
PIPE DATA
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 1 31.2 0.995 PL 20.00 PF 6.8 1 0.0 SRCE 52.2 (N/A) 12.9 150 FTG TG PE -1.3 2 3.0 0.0 44.0 0.0 0.253 TL 27.00 PV
Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 3.0 0.0 44.0 0.0 4.0 psi, 31.2 gpm 3 3.0 0.0 40.0 0.0
Pipe: 3 31.2 1.101 PL 50.00 PF 7.9 3 3.0 0.0 40.0 0.0 10.5 150 FTG 1.0 PE -2.6 4 9.0 0.0 29.5 0.0 0.155 TL 51.00 PV
Pipe: 4 31.2 1.025 PL 5.00 PF 5.3 4 9.0 0.0 29.5 0.0 12.1 150 FTC 19.0 PE -1.7 5 13.0 H.S. 22.5 5.0 0.219 TL 24.00 PV
Pipe: 5 26.2 1.101 PL 6.00 PF 1.5 5 13.0 H.S. 22.5 5.0 8.8 150 FTG 7.0 PE -2.6 6 19.0 0.0 18.5 0.0 0.112 TL 13.00 PV
Pipe: 6 26.2 1.101 PL 4.00 PF 1.8 6 19.0 0.0 18.5 0.0 8.8 150 FTG 12.0 PE 0.0 7 19.0 0.0 16.7 0.0 0.112 TL 16.00 PV
Pipe: 7 17.8 1.101 PL 9.00 PP 1.3 7 19.0 0.0 16.7 0.0 6.0 150 FTG 15.0 PE 0.0 8 19.0 0.0 15.4 0.0 0.055 TL 24.00 PV
Pipe: 8 4.7 1.101 PL 67.00 PF 0.4 8 19.0 0.0 15.4 0.0 1.6 150 FTC 28.0 PE 0.0 9 19.0 0.0 14.9 0.0 0.005 TL 95.00 PV
Pipe: 9 8.4 1.101 PL 94.00 PF 1.8 7 19.0 0.0 16.7 0.0 2.8 150 FTG 35.0 PE 0.0 9 19.0 0.0 14.9 0.0 0.014 TL 129.00 PV Pipe: 10 13.0 1.101 PL 10.00 PF 0.6 8 19.0 0.0 15.4 00 4.4 150 FTG 10.0 PE -4.3 11 29.0 0.0 10.4 0.0 0.031 TL 20.00 PV
Pipe: 11 13.1 1.101 PL 11.00 PF 0.9 9 19.0 0.0 14.9 0.0 4.4 150 FTC 17.0 PE -4.3 10 29.0 0.0 9.7 0.0 0.031 TL 28.00 PV Pipe: 12 5.2 1.101 PL 79.00 PF 0.7 11 29.0 0.0 10.4 0.0 1.8 150 FTG 46.0 PE 0.0 10 29.0 0.0 9.7 0.0 0.006 TL 125.00 PV
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 3 DATE: 2/15/2019 C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC
PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI)
Pipe: 13 7.8 1.101 PL 68.00 PF 1.7 11 29.0 0.0 10.4 0.0 2.6 150 FTG 71.0 PE -1.3 14 32.0 0.0 7.5 0.0 0.012 TL 139.00 PV
Pipe: 14 18.4 1.101 PL 3.00 PF 0.8 10 29.0 0.0 9.7 0.0 6.2 150 FTG 10.0 PE -1.3 12 32.0 0.0 7.7 0.0 0.058 TL 13.00 PV
Pipe: 15 13.2 1.101 PL 2.00 PF 0.4 12 32.0 0.0 7.7 0.0 4.4 150 FTG 12.0 PE 0.0 13 32.0 4.9 7.2 13.2 0.031 TL 14.00 PV
Pipe: 16 13.0 1.101 PL 2.00 PF 0.4 14 32.0 0.0 7.5 0.0 4.4 150 FTG 12.0 PE 0.0 15 32.0 4.9 7.0 1.3.0 0.031 TL 14.00 PV
Pipe: 17 5.2 1.101 PL 11.00 PF 0.2 12 32.0 0.0 7.7 0.0 1.7 150 FTG 25.0 PE 0.0 14 32.0 0.0 7.5 0.0 0.006 TL 36.00 PV
NOTES (HASS):
Calculations were performed by the HASS 8.
8
D
c
o
m
p
u
t
e
r
p
r
o
g
r
a
m
in accordance with NFPA13 (2016)
under license no. 38071930 granted by
HRS Systems, Inc.
208 Southside Square
Petersburg, TN 37144
(931) 659-9760
The system has been calculated to provi
d
e
a
n
a
v
e
r
a
g
e
imbalance at each node of 0.001 gpm and
a
m
a
x
i
m
u
m
imbalance at any node of 0.010 gpm.
Total pressure at each node is used in ba
l
a
n
c
i
n
g
t
h
e
s
y
s
t
e
m
.
Maximum water velocity is 12.9 ft/sec at
p
i
p
e
1
.
Items listed in bold print on the cove
r
s
h
e
e
t
are automatically transferred from the
c
a
l
c
u
l
a
t
i
o
n
r
e
p
o
r
t
.
Available pressure at source node 1 un
d
e
r
f
u
l
l
f
l
o
w
c
o
n
d
i
t
i
o
n
s
i
s
60.99 psi with a flow of 34.91 gpm.
PIPE FITTINGS TABLE
HASS Pipe Table Name: standard.pip
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 4 DATE: 2/15/2019
C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 MD CALC
PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyViv GatViv AimChk
D
P
V
l
v
N
P
T
e
e
1.025 1.79 4.47 1.79 4.47 5.36 0.89 8.93 1.79 4.47 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet
(in) F E T R K C G F45 Eli Tee RunT Kpig ChkVlv Gate 1.101 1.40 2.50 6.00 1.70 1.00 8.00 0.40
PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R K C G N Eli Tee 45-Eli TeeRun Koupig ChkVlv GatVlv
N
P
T
e
e
0.995 2.00 6.00 1.00 2.00 0.00 6.00 0.00 6.00
SPRINKLER SYSTEM HYDRAULIC ANALYS
I
S
Page 5 DATE: 2/15/2019
C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC
WATER SUPPLY ANALYSIS
Static: 61.00 psi Resid: 60.00 psi
F
l
o
w
:
5
0
0
.
0
g
p
x
n
80.0
70.0
60.1) G
A
U 50?)
G
E 40.0
LEGEND
Available pressure
60.99 psi @ 31.2 gpm
Required pressure
52.16 psi @ 31.2 gpm
Source Supply Curve
System Demand Curve
P
R 30.0
E
20.0
S
U
10.0
R
E
mm
p
-14 .7
10(150 200 250 300 350 400 450 500
FLOW (GPM)
Dte: (1) Dashed Lines indicate ext
r
a
p
o
l
a
t
e
d
v
a
l
u
e
s
f
r
o
m
T
e
s
t
R
e
s
u
l
t
s
SPRINKLER SYSTEM HYDRAULIC ANALYSIS
Page 6 DATE: 2/15/2019
C:\HASS\DATA\18-0471FF.SDF JOB TITLE: OLIVER BARN 2 HD CALC
WATER SUPPLY CURVE
72+
66+
0\\\\\\\\\\\\\\\\\ 60+ <-60.0 psi @ 500 gpxn
Flow Test Point
54+
x
P 48+
RI
El
S 42+
UI
RI
Ef
36+
24+
18+
12+ LEGEND
I U
I X = Required Water Supply
52.16 psi 8 31.2 gpin U 6+
I 0 = Available Water Supply
60.99 psi @ 31.2 gpm 'I
II
+------+ --------+--------+---
-
-
-
-
-
-
+
-
-
-
-
-
-
-
-
-
-
-
+
200 300 400 500 600 700 800 900 1000 FLOW (GPM)
tqco
Fire Protection
Products
Worldwide www.tyco-flre.com Contacts
RAPID RESPONSE Series LFII Residential
49 K-factor Concealed Pendent Sprinkler
Flat Plate, Wet Pipe and Dry Pipe Systems
General
Description
TYCO RAPID RESPONSE Series LFII
Residential 4.9K Concealed Pendent
Sprinklers (TY3596) are decorative,
fast response, fusible solder sprinklers
designed for use in residential occu-
pancies such as homes, apartments,
dormitories, and hotels.
The cover plate assembly conceals
the sprinkler operating components
above the ceiling. The flat profile of the
cover plate provides the optimum aes-
thetically appealing sprinkler design.
In addition, the concealed design of
the Series LFII Residential Concealed
Pendent Sprinklers (1Y3596) provides
1/2 inch (12,7 mm) vertical adjustment.
This adjustment provides a measure of
flexibility when cutting fixed sprinkler
drops.
The Series LFII Residential Concealed
Sprinklers are intended for use in the
following scenarios:
wet and dry pipe residential sprin-
kler systems for one- and two-fam-
ily dwellings and mobile homes per
NFPA 130
wet and dry pipe residential sprinkler
systems for residential occupancies
up to and including four stories in
height per NFPA 13R
wet and dry pipe sprinkler systems
for the residential portions of any
occupancy per NFPA 13
IMPORTANT
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 6
The Series LFII Residential Concealed
Pendant Sprinklers (TY3596) has
been designed with heat sensitivity
and water distribution characteristics
proven to help in the control of residen-
tial fires and to improve the chance for
occupants to escape or be evacuated.
The Series LFil Residential Con-
cealed Pendent Sprinklers (1Y3596)
are shipped with a Disposable Pro-
tective Cap. The Protective Cap Is
temporarily removed for Installation,
and then it can be replaced to help
protect the sprinkler while the ceiling
Is being installed or finished. The tip of
the Protective Cap can also be used
to mark the center of the ceiling hole
into plaster board, ceiling tiles, etc.
by gently pushing the ceiling product
against the Protective Cap. When the
ceiling installation is complete the Pro-
tective Cap is removed and the Cover
Plate Assembly installed.
Dry Pipe System Application The Series LFII Residential Concealed
Pendent Sprinklers offers a laboratory
approved option for designing dry pipe
residential sprinkler systems, whereas,
most residential sprinklers are labora-
tory approved for wet systems only.
Through extensive testing, It has been
determined that the number of design
sprinklers (hydraulic design area) for
the Series LFll Residential Concealed
Pendant Sprinklers (TY3596) need
not be increased over the number of
design sprinklers (hydraulic design
area) as specified for wet pipe sprinkler
systems, as is accustomed for density/
area sprinkler systems designed per
NFPA 13.
Consequently, the Series LFII Residen-
tial Concealed Pendent Sprinklers offer
the features of non-water filled pipe in
addition to not having to increase-the number of design sprinklers (hydraulic
design area) for systems designed to
NFPA 13,13D, or 13R.
FEBRUARY 2015
NOTICEI
The Series LFII ResidentIal Concealed
Pendent Sprinklers (TY3596) described
herein must be installed and main-
taThed in compliance with this docu-
ment and with the applicable standards
of the National Fire Protection Associa-
tion INFPA), in addition to the standards
of any authorities having jurisdiction.
Failure to do so may impair the perfor-
mance of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Number (SIN)
TY3596
TFP442
TFP442
Page 2 of 6
BODY
(1/2' NFl) ----.•...•..._-••..
CAP
SADDLE
SUPPORT
CUP WITH ROLL FORMED
THREADS
GUIDE
PIN
GUIDE PIN
HOUSING
DEFLECTOR
THREAD INTO
SUPPORT
CUP UNTIL
MOUN11NG
SURFACE IS
FLUSH WITH
CEILING
SOLDER
TAB ASSEMBLY
FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL
CONCEALED PENDENT SPRINKLER (TY3596)
/ SOLDER LINK H H ELEMENT I I II I I II I I II I I I I
'I DEFLECTOR
(OPERATED
POSITION) SPRINKLER/SUPPORT CUP
ASSEMBLY
RETAINER
I WITH THREAD ii - DIMPLES
COMPRESSION
SCREW
SPRINKLER
WRENCHING
AREA
SEALING
ASSEMBLY
EJECTION
SPRING
COVER
PLATE
LEVER
WRENCH
RECESS
0 t
PUSH WRENCH
INTO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 2
W-TYPE 18
SPRINKLER WRENCH
2-1/2' DIA.
SPRINKLER- (63,5 mm] 1/2 (12,7 mm) FACE OF SUPPORT CUP 1121 \ THREADED SPRINKLER \ ASSEMBLY NPT ADJUSTMENT FUTING
OPERATED I 'Ik / I
.----- V
,
"SPRINKLER
J 11 PLATE I- (47.6 mm
RETAINER
Jf
(3,2 mm)
I 1-7/8'±1/4' COVER I
1/8' GAP t6,4 mm)
311f61 J
\
I 7/88 (22.2 COVER- SPRINKLER-
MOUNTING RETAINER SUPPORT CUP
SURFACE
__________________
__
ASSEMBLY ASSEMBLY (4,8 mm \1 1-1,8' (28,6 mm)
3-3/16' DIA.
DI SPOSABLE DEFLECTOR IN (81.0 mm)
TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEA
L
E
D
P
E
N
D
E
N
T
S
P
R
I
N
K
L
E
R
(
T
Y
3
5
9
6
)
INSTALLATION DIMENSIONS/PROTECTIVE CAP/AC
T
I
V
A
T
E
D
D
E
F
L
E
C
T
O
R
TFP442
Page 3 of 6
Technical
Data
Approvals
UL and C-UL Listed
NYC Approved under MEA 44-03-E-2NSF
Certified to NSF/ANSI 61
The TYCO RAPID RESPONSE Series LFll Residential Concealed Pendent Sprinklers
are only Listed with the Series LFII Con-
cealed Cover Plates having a factory-ap-
plied finish.
Cover Plates can be ordered by following
the instructions in the Ordering Procedure
section.
Maximum Working Pressure 175 psi (12,1 bar)
Discharge Cpfflcient
K=4.9 gpm/psl (70,6 1pm1bar112)
Temperature Rating
160°F (71°C) Sprinkler with
139°F (59°C) Cover Plate
Vertical Adjustment
112 Inch (12,7 mm)
Finishes
Refer to Ordering Procedure section.
Physical Characteristics
Body.........................Brass
Cap.........................Bronze
Saddle .......................Brass
Sealing Assembly ....... Beryllium Nickel
w/TEFLON Soldered Link Halves............Nickel
Lever........................Bronze
Compression Screw.............Brass
Deflector ................... Copper or
Brass Guide Pin Housing.............Bronze
Guide Pins .............Stainless Steel
or Bronze Support Cup ...................Steel
Cover Plate ..................Copper
Retainer......................Brass
Cover Plate
Ejection Spring..........Stainless Steel
Operation
When exposed to heat from a fire, the
Cover Plate, which is normally soldered
to the Support Cup at three points, tails
away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated
position. The fusible link of the sprin-kler assembly is comprised of two link halves that are soldered together with
a thin layer of solder. When the rated temperature is reached, the solder
melts and the two link halves separate
allowing the sprinkler to activate and
flow water.
Design Criteria
TYCO RAPID RESPONSE Series LFII
Residential Concealed Pendent Sprin-
klers (1Y3596) are UL and C-UL Usted
for installation in accordance with this
section.
Note: When conditions exist that are
outside the scope of the provided cr1-
teria, refer to the Residential Sprinkler
Design Guide TFP490 for the manu-
facturer's recommendations that may
be acceptable to the authority having jurisdiction.
System Types
Per the UL Usting, wet pipe and dry pipe systems may be utilized. Per the
C-UL Listing, only wet pipe systems may be utilized.
Refer to Technical Data Sheet TFP485
about the use of residential sprinklers in
residential dry pipe systems.
Ceiling Types
Smooth flat horizontal, or beamed, or
sloped, in accordance with the 2013
Edition of NFPA 13D, 13R, or 13 as
applicable.
Hydraulic Design
(NFPA 13D and 13R)
For systems designed to NFPA 13D
or NFPA 13R, the minimum required
sprinkler flow rates are given In
Tables A and B as a function of tem-
perature rating and the maximum
allowable coverage areas. The
sprinkler flow rate is the minimum
required discharge from each of the
total number of design sprinklers" as
specified in NFPA 13D or NFPA 13R.
The number of "design sprinklers"
specified in NFPA 13D and 13R for wet
pipe systems Is to be applied when
designing dry pipe systems.
Hydraulic Design
(NFPA 13)
For systems designed to NFPA 13, the
number of design sprinklers is to be
the four most hydraulically demanding
sprinklers. The minimum required dis-
charge from each of the four sprinklers
is to be the greater of the following:
the flow rates given in Tables A and
B as a function of temperature rat-
ing and the maximum allowable cov-
erage area
a minimum discharge of
0.1 gpm/ft.2 over the design area comprised of the four (4) most
hydraulically demanding sprinklers
for actual coverage areas protected
by the four (4) sprinklers
The number of design sprinklers speci-
fied in NFPA 13 for wet pipe systems Is
to be applied when designing dry pipe
systems.
Dry Pipe System Water Delivery
When using the Series LFll Residen-
tial Concealed Pendent Sprinklers
(1Y3596) in dry pipe sprinkler systems,
the time for water delivery must not
exceed 15 seconds forthe most remote
operating sprinkler.
Obstruction to
Water Distribution
Sprinklers are to be located in accor-
dance with the obstruction rules of
NFPA 13D, 13R, and 13 as applicable
for residential sprinklers as well as with
the obstruction criteria described within
the Technical Data Sheet TFP490.
Operational SensItivity
The sprinklers are to be installed rela-tive to the ceiling mounting surface as shown in Figure 3.
Sprinkler Spacing
The minimum spacing between sprin-
klers is 8 feet (2,4 m). The maximum
spacing between sprinklers cannot
exceed the length of the coverage area
(Ref. Table A or B) being hydraulically
calculated (e.g., maximum 12 feet for a
12 ft. x 12 ft. coverage area, or 20 feet
for a 20 ft. x 20 ft. coverage area).
The Series LFll must not be used
In applications where the air pres-
sure above the ceiling Is greater than
that below. Down drafts through the
Support Cup could delay sprinkler
operation in a fire situation.
TFP442
Page 4 of 6
WET PIPE SYSTEM Minimum Flow and Residual Pressure2 ' Coverage
Max imum Maximum
Spacing Ordinary Temp. Rating
Minimum
Area 160°F (71°C) Ft x Ft Ft.
(m) Deflector to Installation Spacing Flow Pressure (mx m) Ceiling Type Ft. gpm psi
(m) (1pm) (bar)
12 X 12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings
7/8 to 1-1/8 14x14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48)
Beamed
Ceilings per
NFPA 13D Concealed
16x16 16 13 7.0 (4,9x4,9) (4,9) (49.2) (0148) 13R, or 13.
Installed in
(2,4)
18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64.3) (0,83) 7/8to1-1/8
inches below 20x20 20 20 16.7 bottom of (6,1) (75,7) (1,15) beam
Notser
For coverage area dimensions less than or between than Indicated.
u
s
e
t
h
e
m
i
n
i
m
u
m
r
e
q
u
i
r
e
d
S
o
w
f
o
r
t
h
e
r
,
e
x
t
h
i
g
h
est coverage area for which hydraulic deaign whavilai are stated.
Requirement Is based on minimum flow in gem Opm) from each aprinlder. The associated resid
u
a
l
p
r
e
e
a
u
r
e
e
a
r
e
c
a
l
c
u
l
a
t
e
d
u
s
i
n
g
the nominal K-factor. Refella Hydraulic Design under the D
e
s
i
g
n
C
r
i
t
e
r
i
a
s
e
c
t
i
o
n
.
For NFPA 13 residential applications, the greater 010.1 gprnflL' over the design area or the 110w In accordance with the
c
r
i
t
e
r
i
a
I
n
this table must be used.
TABLE A
WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLA
T
P
L
A
T
E
C
O
N
C
E
A
L
E
D
P
E
N
D
E
N
T
S
P
R
I
N
K
L
E
R
(
T
Y
3
5
9
6
)
NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN C
R
I
T
E
R
I
A
DRY PIPE SYSTEM Minimum Flow and Residual Pressure 2-2 Maximum
a Covere Maximum
Spacing Ordinary Temp. Rating
Minimum
Area
Ft. x Ft . Ft. 160°F (71°C)
Deflector to Installation Spacing Flow Pressure (mx m) (m)
Ceiling Type Ft. gpm psi
(m) (1pm) (bar)
12 X 12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3 x 4,3) (4,3) (53,0) (0,57)
Beamed
gs per NFPA
Calling
or Concealed 8
(2,4)
16 IC 16
(4,9x4,9) 16
(4,9) 15
(56,8) (0,65) 13R, or 13.
Installed in 18x18 18 18 13.5 beam (5,5x5,5) (515) (6811) (0193) 7/8to1-1/8
inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam
Notes:
I. For coverage area dimensions less than or between those Indi
c
a
t
e
d
,
u
s
e
t
h
e
m
i
n
i
m
u
m
r
e
q
u
i
r
e
d
f
l
o
w
f
o
r
t
h
e
n
e
x
t
highest coverage
area for which hydraulic design crIterIa are stated. 2. Requirement Is based on minimum 110w In gpm flpm) from each sprinider. The associated residual pressures are calculated using
the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. 8. For NFPA 13 residential applications, the greater 010.1 gpmflt' over the design area or the flow In accordance with the criteria in
this table must be used.
TABLE B
DRY PIPE SYSTEM RAPID RESPONSE SERIES LFI1 RESIDENTIAL 4.
9
K
-
F
A
C
T
O
R
F
L
A
T
P
L
A
T
E
C
O
N
C
E
A
L
E
D
P
E
N
D
E
N
T
(
T
Y
3
5
9
6
)
NFPA 130, 13R, AND 13 HYDRAULIC DESIGN C
R
I
T
E
R
I
A
TFP442
Page 5 of 6
Installation
TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin-
klers (TY3596) must be installed in
accordance with this section.
General Instructions
Damage to the fusible Link Assembly
during installation can be avoided by
handling the sprinkler by the support
cup only (I.e., do not apply pressure to
the fusible Link Assembly).
A 1/2 inch NPT sprinkler joint should be
obtained with a minimum to maximum
torque of 7 to 14 lbs.-ft. (9,5 to 19,0 Nm).
Higher levels of torque may distort the
sprinkler Inlet with consequent leakage
or Impairment of the sprinkler.
Do not attempt to compensate for
insufficient adjustment In the Cover
Plate I Retainer Assembly by under-
or over-tightening the Sprinkler. Read-
just the position of the sprinkler fitting
to suit
Step 1. The sprinkler must only be
installed in the pendent position and
with the centerline of the sprinkler per-
pendicular to the mounting surface.
Step 2. Remove the Protective Cap.
Step 3. With pipe thread sealant
applied to the pipe threads, and using
the W-Type 18 Wrench shown in Figure
2, install and tighten the Sprinkler /
Support Cup Assembly into the fitting.
The W-Type 18 Wrench will accept a
1/2 inch ratchet drive.
Step 4. Replace the Protective Cap by
pushing it upwards until it bottoms out
against the Support Cup. The Protec-
tive Cap helps prevent damage to the
Deflector and Guide Pins during ceiling
installation and/or during application of
the finish coating of the ceiling. It may
also be used to locate the center of the
clearance hole by gently pushing the
ceiling material against the center point
of the Cap.
Note: As long as the protective Cap
remains in place, the system is consid-
ered to be "Out Of Service."
Step 5. After the ceiling has been completed with the 2-1/2 inch (63 mm)
diameter clearance hole and in prep-
aration for installing the Cover Plate
Assembly, remove and discard the Pro-
tective Cap, and verify that the Deflec-
tor moves up and down freely.
If the sprinkler has been damaged and
the Deflector does not move up and
down freely, replace the entire sprinkler
assembly. Do not attempt to modify or
repair a damaged sprinkler.
Step S. Screw on the Cover Plate
Assembly until its flange comes in
contact with the ceiling.
Do not continue to screw on the Cover
Plate Assembly such that It lifts a
ceiling panel out of its normal position.
If the Cover Plate Assembly cannot
be engaged with the Mounting Cup
or the Cover Plate Assembly cannot
be engaged sufficiently to contact the
ceiling, the Sprinkler Fitting must be
repositioned.
Care and
Maintenance
TYCO RAPID RESPONSE Series LFll
Residential Concealed Pendent Sprin-
klers (1Y3596) must be maintained
and serviced in accordance with this
section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
which it controls, permission to shut
down the affected fire protection
system must be obtained from the
proper authorities and all personnel
who may be affected by this action
must be notified.
Absence of a Cover Plate may delay the
sprinkler operation in a fire situation.
When properly installed, there is a
nominal 1/8 inch (3,2 mm) air gap
between the lip of the Cover Plate and
the ceiling, as shown in Figure 3. This
air gap is necessary for proper opera-
tion of the sprinkler by allowing heat
flow from a fire to pass below and
above the Cover Plate to help assure
appropriate release of the Cover Plate
in a fire situation. If the ceiling is to be
repainted after the installation of the
Sprinkler, care must be exercised to
ensure that the new paint does not seal
off any of the air gap.
Factory painted Cover Plates must not
be repainted. They should be replaced,
If necessary, by factory painted
units. Non-factory applied paint may
adversely delay or prevent sprinkler
operation in the event of a fire.
Do not pull the Cover Plate relative to
the Enclosure. Separation may result.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or otherwise
altered after leaving the factory. Modi-
fied or over heated sprinklers must be
replaced.
Care must be exercised to avoid
damage before, during, and after instal-
lation. Sprinklers damaged by drop-
ping, striking, wrench twist/slippage,
or the like, must be replaced.
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation (e.g., NFPA 25), In addition to
the standards of any other authorities
having jurisdiction. Contact the Install-
ing contractor or product manufacturer
with any questions.
The owner must assure that the sprin-
klers are not used for hanging any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster, otherwise, non-
operation in the event of a fire or inad-
vertent operation may result.
Automatic sprinkler systems should be
inspected, tested, and maintained by a
qualified Inspection Service in accor-
dance with local requirements and/or
national codes.
TFP442
Page 6 of 6
Limited
Warranty
For warranty terms and conditions, visit www.tycotire.com.
Ordering
Procedure
Contact your local distributor for
availability. When placing an order,
indicate the full product name and part number (P/N).
Sprinkler Assemblies
Specify: Series LFll (TY3596) 4.9K
Residential Concealed Pendent Sprin-
kler without Cover Plate Assembly,
P/N 51-112-1-160
Cover Plate Assemblies
Specify: Cover Plate Assembly with
(specify) finish for the Series LFIl
(TY359 4.9K Residential Concealed Pendent Sprinkler, P/N (specify):
ivory (RAL1015) ...........P/N 56-202-0435 Beige AL1001) ........... P/N 56-202-2-135 Pure White * (RAL9010) .....P/N 56-202-3435 Signal White ** (RAL9003) ... P/N 56-202-4435 Grey White (RAL9002) ...... P/N 56-202-5-135 Brown (RAL.8028) .......... P/N 56-202-6-135 Black (RAL9005) ..........P/N 56-202-7-135 Brushed Brass ............ P/N 56-202-8435 Brushed Chrome ..........P/N 56-202-9435
Custom Paint ............. P/N 56-202-X-135
Eastern llemlspiere sales only PrevIously known as Bilght White
Note: All Custom Cover Plates are
painted using Sherwin Williams Interior
Latex Paint. Contact Tyco Customer
Service with any questions related to
custom orders.
Sprinkler Wrench
Specify: W-Type 18 Sprinkler Wrench,
P/N 56-000-1-265
GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-2154162-0700 Copyright 02015 Tyco Fire Products, I.P. MI rights reserved. TEFLON lsb-ademwlc of The DuPont Corporation.
tqco
Ffre Protection
Products
Worldwide wco-fire.com Contacts
RAPID RESPONSE Series LFII Residential
49 K-factor Pendent Sprinkler
Wet Pipe and Dry Pipe Systems
General
Description
TYCO RAPID RESPONSE Series
LFII Residential 4.9K Pendent and
Recessed Pendent Sprinklers (TY2234)
are decorative, fast response, frangi-
ble bulb sprinklers designed for use
in residential occupancies such as
homes, apartments, dormitories, and
hotels. When aesthetics and optimized
flow characteristics are the major con-
sideration, the Series LFII Residential
Sprinklers (TY2234) should be the first
choice.
The Series LFII Residential Sprinklers
are intended for use in the following
scenarios:
wet and dry pipe residential sprin-
kler systems for one- and two-fam-
ily dwellings and mobile homes per
NFPA 13D
wet and dry pipe residential sprinkler
systems for residential occupancies
up to and including four stories in
height per NFPA 13R
wet and dry pipe sprinkler systems
for the residential portions of any
occupancy per NFPA 13
The recessed version of the Series
LFII Residential Sprinklers is intended
for use in areas with finished ceilings.
It employs a two-piece Style 20
Recessed Escutcheon. The Recessed
Escutcheon provides 1/4 inch
(6,4 mm) of recessed adjustment or up
to 1/2 inch 02,7 mm) of total adjustment
from the flush ceiling position. The
IMPORTANT Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-ponents. Improper handling and
installation can permanently damage
a sprinkler system or its components and cause the sprinkler to fail to
operate in a fire situation or cause it
to operate prematurely.
Page 1 of 6
adjustment provided by the Recessed
Escutcheon reduces the accuracy to
which the pipe drops to the sprinklers
must be cut.
The Series LFll Residential Sprinklers
have been designed with heat sensi-
tivity and water distribution charac-
teristics proven to help in the control
of residential fires and to improve the
chance for occupants to escape or be
evacuated.
Dry Pipe System Application
The Series LFII Residential Pendent and Recessed Pendent Sprinklers
offers a laboratory approved option
for designing dry pipe residential sprin-
kler systems, whereas, most residential
sprinklers are laboratory approved for
wet systems only.
Through extensive testing, It has been
determined that the number of design
sprinklers (hydraulic design are for
the Series LFII Residential Pendent and
Recessed Pendent Sprinklers (TY2234)
need not be increased over the number
of design sprinklers (hydraulic design
area) as specified for wet pipe sprinkler
systems, as is accustomed for density/
area sprinkler systems designed per
NFPA 13.
Consequently, the Series LFII Resi-
dential Sprinklers offer the features
of non-water filled pipe in addition
to not having to increase the number
of design sprinklers (hydraulic
design area) for systems designed to
NFPA 13,13D, or 13R.
NOTICE
The Series LFII Residential Pendent
and Recessed Pendent Sprinklers
(Y2234) described herein must be
Installed and maintained in compliance
with this document and the applicable
standards of the National Fire Protec-
tion Association (NFPA), in addition to
the standards of any authorities having
Jurisdiction. Failure to do so may impair
the performance of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
MARCH 2015
Sprinkler
Identification
Number (SIN)
1V2234
Technical
Data
Approvals
UL Listed
(for use with wet pipe and dry pipe sys-
tems)
C-UL Listed
(for use only with wet pipe systems)
Certified to all requirements of
NSF/ANSI 61
(Refer to the Design Criteria section fords-
tails on these approvals.)
Maximum Working Pressure 175 psi 02,1 bar)
Discharge Coefficient
K=4.9 gpm/3si112 (70,6 Ipm/bar'/2)
Temperature Rating
155°F (68°C) or 175°F (79°C)
Finishes
Natural Brass, Pure White, Signal White, or
Chrome Plated
Physical Characteristics Frame........................Brass
Button ......................Copper Sealing Assembly......Beryllium Nickel
w1rEFLON Bulb (3 mm)...................Glass
Compression Screw............Bronze
Deflector .....................Bronze
TFP400
TFP400
Page 2 of 6
7/16' (11.1 mm)
1/2' ESCUTCHEON Components:
2-7/8' ()
NOMINAL NPT PLATE SEATING
1 - Frame MAKE-IN SURFACE (73,0 mm) 2 - Button
3 - Sealing Assembly 1
4 - Bulb
5 - Compression 2
Screw
2-1/4'
(/1
6 - Deflector* : (57,2 mm) iiiii!!
1.5/8'
(41,3 mm) WRENCH STYLE 20
RECESSED 5
FLATS
*Temperature
-.
ESCUTCHEON rating is
Indicated on
Deflector.
CROSS SECTION PENDENT RECESSED PENDENT
FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL
4.9K PENDENT AND RECESSED PENDENT SPRINKLER
S
(
T
Y
2
2
3
4
)
-
2-7/8' DIA.
7/16±1/8' (73,0 mm) 1/2' (12,7 mm) (11,1*3,2mm) 2-1/4' DIA. I 1/4' (6,4 mm)
FACE OF mm) 21 SPRINKLER
r-57'2
MOUNTING FITTING f - PLATE
-
MOUNTING
SURFACE
m)
_
2(3
1Y' 9 mm) CLOSURE
1-1/8' (28,6 mm)
FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT
S
P
R
I
N
K
L
E
R
Design
Criteria
The TYCO RAPID RESPONSE Series
LFII Residential 4.9K Pendent and
Recessed Pendent Sprinklers are UL
and C-UL Listed for Installation in
accordance with this section.
Residential Sprinkler
Design Guide
When conditions exist that are outside
the scope of the provided criteria, refer
to the Residential Sprinkler Design
Guide TFP490 for the manufactur-
er's recommendations that may be
acceptable to the local authority having
jurisdiction.
Operation
The glass bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to
activate and flow water.
tWRENCH RECESS (END 'A' USED
FOR TY2234)
FIGURE 3
V/-TYPE 6
SPRINKLER WRENCH
WRENCH
RECESS
6
t
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 4
W-TYPE 7 RECESSED
SPRINKLER WRENCH
System Typos
Per the UL Listing, wet pipe and dry
pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems
may be utilized.
Refer to Technical Data Sheet TFP485
for the use of residential sprinklers in
residential dry pipe systems.
Ceiling Types
Smooth flat horizontal, or beamed, or
sloped, in accordance with the 2013
Edition of NFPA 13D, 13R, or 13, as
applicable.
TFP400
Page 3 of 6
Hydraulic Design
(NFPA 13D and 13R)
For systems designed to NFPA 130
or NFPA 13R, the minimum required
sprinkler flow rates are given in
Tables A and B as a function of tem-
perature rating and the maximum
allowable coverage areas. The
sprinkler flow rate is the minimum
required discharge from each of the
total number of "design sprinklers" as
specified in NFPA 130 or NFPA 13R.
The number of "design sprinklers
specified in NFPA 130 and 13R for wet
pipe systems is to be applied when
designing dry pipe systems.
Hydraulic Design (NFPA 13)
For systems designed to NFPA 13, the
number of design spnnklerê is to be the four most hydraulically demanding
sprinklers. The minimum required dis-
charge from each of the four sprinklers
is to be the greater of the following:
The flow rates given in Table A or
B as a function of temperature
rating and the maximum allowable
coverage area.
A minimum discharge of 0.1 gpm/ft2 over the "design aree comprised
of the four most hydraulically
demanding sprinklers for actual
coverage areas protected by the
four sprinklers.
The number of design sprinklers speci-
fied in NFPA 13 for wet pipe systems Is
to be applied when designing dry pipe
systems.
Dry Pipe System Water Delivery When using the Series LFII Residential
Sprinklers (TY2234) In dry pipe sprin-
kler systems, the time for water deliv-
ery must not exceed 15 seconds for the
most remote operating sprinkler.
Obstruction to
Water Distribution
Sprinklers are to be located In accor-
dance with the obstruction rules of
NFPA 13D, 13R, and 13 as applicable
for residential sprinklers as well as with
the obstruction criteria described within
the Technical Data Sheet TFP490.
Operational Sensitivity
Sprinklers are to be installed with a
deflector-to-ceiling distance of 14/4 to
4 inches.
Sprinkler Spacing
The minimum spacing between sprin-
klers is 8 feet (2,4 m). The maximum
spacing between sprinklers cannot
exceed the length of the coverage area
(Table A or B) being hydraulically cal-
culated (e.g., maximum 12 feet for a
12 ft. x 12 ft. coverage area, or 20 feet
for a 20 ft. x 20 ft. coverage area).
Installation
TYCO RAPID RESPONSE Series
LFII Residential 4.9K Pendent and
Recessed Pendent Sprinklers must
be Installed in accordance with this
section.
General Instructions
Do not install any bulb type sprinkler
if the bulb is cracked or there Is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 Inch
(1,6 mm).
A leak-tight 1/2 inch NPT sprinkler joint
should be obtained by applying a min
imum-to-maximum torque of 7 to 14
ft.-lbs. (9,5 to 19,0 Nm). Higher levels
of torque can distort the sprinkler Inlet
with consequent leakage or impairment
of the sprinkler.
Do not attempt to compensate for
insufficient adjustment In an Escutch-
eon Plate by under- or over- tightening
the sprinkler. Re-adjust the position of
the sprinkler fitting to suit.
Series LFii Residential
Pendent Sprinklers
The Series LFII Residential Pendent
Sprinklers must be installed in accor-
dance with the following instructions:
Step I Install pendent sprinklers in the
pendent position with the deflector par-
allel to the ceiling.
Step 2. With pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Figure 3). With ref-
erence to Figure 1, apply the W-Type 6
Sprinkler Wrench to the wrench flats.
Series LFli Residential
Recessed Pendent Sprinklers
The Series LFII Residential Recessed
Pendent Sprinklers must be installed
in accordance with the following
Instructions:
Step A. Install recessed pendant sprin-
klers in the pendent position with the
deflector parallel to the ceiling.
Step B. After installing the Style 20
Mounting Plate over the sprinkler
threads and with pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step C. Tighten the sprinkler into the
sprinkler fitting using only the W-Type 7
Recessed Sprinkler Wrench (Figure 4).
With reference to Figure 1, apply the
W-Type 7 Recessed Sprinkler Wrench
to the sprinkler wrench flats.
Step D. After the ceiling has been
Installed or the finish coat has been
applied, slide on the Style 20 Closure
over the Series LFII Residential Sprin-
kler and push the Closure over the
Mounting Plate until its flange comes in
contact with the ceiling.
TFP400
Page 4 of 6
WET PIPE SYSTEM Minimum Flow and Residual Pressure (2113) Maximum
Coveraee Ordinary Temperature Rating
155°F (68°C) Intermediate Temperature Rating
175°F (79°C) Minimum Area
Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft.
Ceiling Type Ft. (mxm) gpm ps i gpm i (m) I/min) (bar) (I/mm)
12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings
1-1/410
4 Inches
14x14 13 7.0 13 7.0 (4,3x4,3) (49,2) (0,48) (49,2) (0,48)
Beamed
Ceilings per
Recessed
using Style 20
Escutcheon or 8
16 x 16 13 7.0 13 7.0 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D
or 13R
non-recessed
per NFPA 13D,
13R, or 13
(2,4) 18x18 17 12.0 17 12.0 (5,5x5,5) (64,3) (0.83) (64,3) (0,83) 1-1/4to1-3/4 inches below bottom of 20x20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1.15) (75,7) (1,15) beam.
Notes:
For coverage area dimensions less than or between those Indicated, use the minimum required flow for the next highest coverage area for which hydraulic design c,ftada are stated.
Rerement Is based on minimum flow in gpm (1pm) from each epilnider. The
a
s
s
o
c
i
a
t
e
d
r
e
s
i
d
u
a
l
p
r
e
s
s
u
r
e
s
a
r
e
c
a
l
c
u
l
a
t
e
d
u
e
k
l
g
t
h
e
n
o
m
i
n
a
l
K-factor. Refer to Hydraulic Design under the Design Cittedaeecticn. For NFPA 13 residential applications, the greater 010.1 gpmMt2 over the design ares or the flow In accordance with the ctfteda in this table must be used.
TABLE A
WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENTAND RECESSED PENDENT SPRINK
L
E
R
S
(TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA
DRY PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum ______________________
Coveraae Ordinary Temperature Rating Intermediate Temperature Rating Area () 155°F (68°C) 175°F (79°C) Minimum Ft. x Ft. IDeflector to Installation Spacing (mxm) Flow Pressure Flow Pressure Ceiling Type pm psi gpm Al(llmJn) (bar) (I/mm) (bar)
12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings
1-1/4104
Inches
14 X 14 14 8.2 14 8.2 (4,3 x 4,3) (53,0) (0,57) (53,0) (0,57)
Beamed
Recessed
using Style 20
Escutcheon or 8
16 x 16 15 9.4 15 9.4 (4,9 x 4,9) (5618) (0,65) (56,8) (0,65)CNFPA
eIl ings
1 per3D
or 13R
non-recessed per NFPA 13D,
13R, or 13
(2,4) 18 x 18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4
inches below
bottom of
20 x 20 21 18.4 21 18.4 Al x 6,1) (79,5) (1,27) (79,5) (1,27) beam.
Notes:
For coverage area dimensions less than or between those Indicated, use the minimum req
u
i
r
e
d
f
l
o
w
f
o
r
t
h
e
n
e
x
t
h
i
g
h
e
s
t
c
o
v
e
r
a
g
e
a
r
e
a
f
o
r
w
h
i
c
h
h
y
d
r
a
u
l
i
c
d
e
s
i
g
n
criteria are stated.
Requirement Is based on minimum flow in gpm (1pm) from each spitnider. The asso
c
i
a
t
e
d
r
e
s
i
d
u
a
l
p
r
e
s
s
u
r
e
s
a
r
e
c
a
l
c
u
l
a
t
e
d
u
s
i
n
g
t
h
e
n
o
m
i
n
a
l
I(-factor. Refer to Hydraulic Design under the Design Ciltefla section.
For NFPA 13 residential applications, the greater of 0.1 gprn/fL2 overthe design area or the flow In accordance with the criteria In this table must be used.
TABLE B
DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4,9K PENDENTAND RECESSED PENDENT SPRINK
L
E
R
S
(
T
Y
2
2
3
4
)
- - NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA
TFP400
Page 5 of 6
Care and
Maintenance
TYCO RAPID RESPONSE Series
LFII Residential 4.9K Pendent and
Recessed Pendent Sprinklers must be
maintained and serviced in accordance
with this section:
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
It controls, permission to shut down the
affected fire protection system must be
obtained from the proper authorities
and notify all personnel who may be
affected by this action.
Absence of the outer piece of an
escutcheon, which is used to cover
a clearance hole, can delay sprinkler
operation in a fire situation.
The owner must assure that the sprin-
klers are not used for hanging any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster, otherwise, non-
operation In the event of a fire or inad-
vertent operation may result.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but.
have not operated, should be replaced
If they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing It with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb (Ref. Installa-
tion section).
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
In compliance with this document, as
well as with the applicable standards
of the National Fire Protection Associa-
tion (e.g., NFPA 25), In addition to the
standards of any authorities having
jurisdiction. Contact the installing con-
tractor or product manufacturer with
any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-flre.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and part number
(P/N).
Sprinkler Assemblies
Specify: Series LFll 4.9K Residential
Pendent Sprinkler (TY2234), (specify
temperature rating), with (specify) finish,
P/N (specify):
155°F (68C)
Natural Brass..............P/N 51-2014-155
Pure White (RAt. 9010)° ......P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4455 Chrome Plated ............. P/N 51-201-9455
175°F (79°C)
Natural Brass .............. PIN 51-201-1-175 Pure White (RAt. 9010)° ......P/N 51-201-3475 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated ............. PIN 51-201-9-175
Eastern Hemisphere sales only
Recessed Escutcheon
Specify: Style 20 Recessed Escutch-
eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TPP77O.
Sprinkler Wrenches
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
TFP400
Page 6 of 6
GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright 02015 Tyco Fire Products, I.P. All rights reserved. tqco TEF wlc LON Is of the DuPont Corporation.
Ffr. Protection Products
Page 1
N41KjW4j 0 MICROFAST® QUICK
RESPONSE PENDENT
SPRINKLER VK302 (K56)
The Viking Corporation, 210 N Industrial Park Dr
i
v
e
,
H
a
s
t
i
n
g
s
M
I
4
9
0
5
8
Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsviklngco
r
p
.
c
o
DESCRIPTION
The Viking Microfasts Quick Response Pendent Spri
n
k
l
e
r
V
K
3
0
2
I
s
a
s
m
a
l
l
thermosensitive glass bulb spray sprinkler availa
b
l
e
w
i
t
h
v
a
r
i
o
u
s
f
i
n
i
s
h
e
s
and temperature ratings to meet design requireme
n
t
s
.
T
h
e
s
p
e
c
i
a
l
P
o
l
y
e
s
t
e
r
,
Poiytetrafiuoroethelyne (PTFE), and Electroless Nickel
P
T
F
E
(
E
N
T
)
c
o
a
t
i
n
g
s
can be used in decorative applications where colors
a
r
e
d
e
s
i
r
e
d
.
I
n
a
d
d
i
t
i
o
n
,
these coatings have been investigated for installatio
n
i
n
c
o
r
r
o
s
i
v
e
a
t
m
o
s
p
h
e
r
e
s
and are listed/approved as corrosion resistant as indi
c
a
t
e
d
i
n
t
h
e
A
p
p
r
o
v
a
l
Charts. (Note: FM Global approves ENT finish as
c
o
r
r
o
s
i
o
n
r
e
s
i
s
t
a
n
t
.
F
M
Global has no approval classification for PTFE and
P
o
l
y
e
s
t
e
r
c
o
a
t
i
n
g
s
a
s
c
o
r
r
o
-
sion resistant.)
LISTINGS AND APPROVALS
cULus Listed: Category VNlV
FM Approved: Class Series 2000
VdS Approved: Certificates G414009 and G414010
LPCB Approved
CE CE Certified: Standard EN 12259-I, EC-certificate of co
n
f
o
r
m
i
t
y
0
8
3
2
-
C
P
D
-
2
0
0
1
CCCF Approved: Approved by the China Certification C
e
n
t
e
r
f
o
r
F
i
r
e
P
r
o
d
u
c
t
s
(
C
C
C
F
)
Refer to Approval Chart I and Design Criteria cULus L
i
s
t
i
n
g
r
e
q
u
i
r
e
m
e
n
t
s
,
a
n
d
r
e
f
e
r
t
o
A
p
p
r
o
v
a
l
C
h
a
r
t
2
a
n
d
D
e
s
i
g
n
C
r
i
t
e
r
i
E
for FM Approval requirements that must be followed.
Viking Technical Data may be found on
The Viking Corporation's Web site at
Specifications:
http:llwww.vlkinggroupinc.com.
Minimum Operating Pressure: 7 psi (0.5 bar)
Rated to 175 psi (12 bar) water working pressure The Web site may include a more recent Factory tested hydrostatically to 500 psi (34.5 bar)
edition of this Technical Data Page. Thread size: 1/2 NPT, 15 mm BSP
Nominal K-Factor: 5.6 U.S. (80.6 metric')
Glass-bulb fluid temperature rated to -65 OF (-55 °C)
Overall Length: 2-1/4 (58 mm)
*cULus Listing, FM Approval, and NFPA 13 Installs require a minimu
m
o
f
7
p
s
i
(
0
.
5
b
a
r
)
.
T
h
e
m
i
n
i
m
u
m
o
p
e
r
a
t
i
n
g
p
r
e
s
s
u
r
e
f
o
r
L
P
C
B
a
n
d
C
E
Approvals ONLY 185 psi (0.35 bar).
Material Standards:
Frame Casting: Brass UNS-C84400 or QM Brass
Deflector: Phosphor Bronze UNS-051000 or Copper U
N
S
-
C
1
9
5
0
0
Bulb: Glass, nominal 3 mm diameter
Belleville Spring Sealing Assembly: Nickel Alloy, coated
o
n
b
o
t
h
s
i
d
e
s
w
i
t
h
P
T
F
E
T
a
p
e
Screw: Brass UNS-C36000
Pip Cap and Insert Assembly: Copper UNS-C11 000 and S
t
a
i
n
l
e
s
s
S
t
e
e
l
U
N
S
-
S
3
0
4
0
0
For PTFE Coated Sprinklers: Belleville Spring-Expose
d
,
S
c
r
e
w
-
N
i
c
k
e
l
P
l
a
t
e
d
,
P
i
p
C
a
p
-
P
T
F
E
C
o
a
t
e
d
For Polyester Coated Sorinklers: Belleville Spring-Expose
d
For ENT Coated Sorinklers: Belleville Spring-Exposed,
S
c
r
e
w
a
n
d
P
l
p
c
a
p
- ENT plated. Ordering Information: (Also refer to the current Vikin
g
p
r
i
c
e
l
i
s
t
.
)
Order Quick Response Pendent Sprinklers by first add
i
n
g
t
h
e
a
p
p
r
o
p
r
i
a
t
e
s
u
f
f
i
x
f
o
r
t
h
e
s
p
r
i
n
k
l
e
r
f
i
n
i
s
h
a
n
d
t
h
e
n
t
h
e
a
p
p
r
o
p
r
i
a
t
e
suffix for the temperature rating to the sprinkler base part n
u
m
b
e
r
.
Finish Suffix: Brass = A, Chrome = F, White Polyester = M
-
M
,
B
l
a
c
k
P
o
l
y
e
s
t
e
r
=
M
-
/
B
,
B
l
a
c
k
P
T
F
E
=
N
,
a
n
d
E
N
T
=
J
N
Temperature Suffix: 135 OF (68 °C) = A, 155 OF (68 °C)
=
B
,
1
7
5
O
F
(
7
9
°
C
)
=
D
,
2
0
0
O
F
(
9
3
°
C
)
=
E
,
2
8
6
O
F
(
1
4
1
°
C
)
=
G
For example, sprinkler VK302 with a Brass finish and a 15
5
O
F
(
6
8
°
C
)
t
e
m
p
e
r
a
t
u
r
e
r
a
t
i
n
g
=
P
a
r
t
N
o
.
1
2
9
7
9
A
B
Form No. F033314 Rev 15.1
(Added CCCF Approval)
TECHNICAL DATA
Protective Sprinkler
Clip Wrench Flat
Protective Sprinkler
Cap
Page 2
N41KjW4j 0 MICROFAST® QUICK
RESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial P
a
r
k
D
r
i
v
e
,
H
a
s
t
i
n
g
s
M
I
49058 Telephone: 269-945-9501 Technical Services:
877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikin
g
c
o
r
p
.
c
c
Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches:
Standard Wrench: Part No. 10896W/13 (available s
i
n
c
e
2
0
0
0
)
.
Wrench for Recessed Pendant Sprinklers: Part No. 1
6
0
3
6
W
/
B
(
a
v
a
i
l
a
b
l
e
s
i
n
c
e
2
0
1
1
)
Optional Protective Sprinkler Cap Remover/Escutcheon Install
e
r
T
o
o
l
*
P
a
r
t
No. 15915 (available since 2010)
**A W ratchet is required (not available from Viking). Allows use from the floor by attaching a length off diamete
r
C
P
V
C
t
u
b
i
n
g
t
o
t
h
e
t
o
o
l
.
I
d
e
a
l
f
o
r
s
p
r
i
n
k
l
e
r
c
a
b
i
n
e
t
s
.
R
e
f
e
r
t
o
B
u
l
l
e
t
i
n
F
0
5
1
8
0
;
Sprinkler Cabinets:
Six-head capacity: Part No. 01724A (available sin
c
e
1971) Twelve-head capacity: Part No. 01725A (available si
n
c
e
1
9
7
1
)
INSTALLATION
Refer to appropriate NFPA Installation Standards.
OPERATION
During fire conditions, the heat-sensitive liquid in th
e
g
l
a
s
s
b
u
l
b
e
x
p
a
n
d
s
,
c
a
u
s
i
n
g
t
h
e
g
l
a
s
s
t
o
s
h
a
t
t
e
r
,
r
e
l
e
a
s
i
n
g
t
h
e
p
i
p
c
a
p
a
n
sealing spring assembly. Water flowing through th
e
s
p
r
i
n
k
l
e
r
o
r
i
f
i
c
e
s
t
r
i
k
e
s
t
h
e
s
p
r
i
n
k
l
e
r
d
e
f
l
e
c
t
o
r
,
f
o
r
m
i
n
g
a
u
n
i
f
o
r
m
s
p
r
a
y
p
a
t
t
e
r
to extinguish or control the fire.
INSPECTIONS, TESTS AND MAINTENANCE
Refer to NFPA 25 for Inspection, Testing and Main
t
e
n
a
n
c
e
r
e
q
u
i
r
e
m
e
n
t
s
.
AVAILABILITY
The Viking Microfasts Quick Response Pendent S
p
r
i
n
k
l
e
r
V
K
3
0
2
i
s
a
v
a
i
l
a
b
l
e
t
h
r
o
u
g
h
a
n
e
t
w
o
r
k
of domestic and international dis
tributors. See The Viking Corporation web site for
t
h
e
c
l
o
s
e
s
t
d
i
s
t
r
i
b
u
t
o
r
o
r
c
o
n
t
a
c
t
T
h
e
V
i
k
i
n
g
C
o
r
p
o
r
a
t
i
o
n
.
GUARANTEE
For details of warranty, refer to Viking's current list pric
e
s
c
h
e
d
u
l
e
o
r
c
o
n
t
a
c
t
V
i
k
i
n
g
d
i
r
e
c
t
l
y
.
ME 0
Figure 1: Standard Sprinkler Wrench 10896W/B
Form No. F_033314 Rev 15.1
Page 3 C
NlKjw4j® MICROFAST® QUICK
RESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive,
H
a
s
t
i
n
g
s
M
l
4
9
0
5
8
Telephone: 269-945-9501 Technical Services: 877-
3
8
4
-
5
4
6
4
F
a
x
:
2
6
9
-
8
1
8
-
1
6
8
0
E
m
a
i
l
:
t
e
c
h
s
v
c
s
@
v
i
k
i
n
g
c
o
r
p
.
c
o
TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES
Ordinary 135 OF (57 °C) 100 OF (38 °C) ' Orange Ordinary 155 OF (68 °C) 100 OF (38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 OF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Po
l
y
e
s
t
e
r
,
B
l
a
c
k
P
T
F
E
,
a
n
d
E
N
T
Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all
t
e
m
p
e
r
a
t
u
r
e
r
a
t
i
n
g
s
e
x
c
e
p
t
1
3
5
OF (57 °C)
Footnotes The sprinkler temperature rating Is stamped on the deflector.
2 Based on NFPA-13. Other limits may apply, depending on fire loading, sp
r
i
n
k
l
e
r
l
o
c
a
t
i
o
n
,
a
n
d
o
t
h
e
r
r
e
q
u
i
r
e
m
e
n
t
s
o
f
t
h
e
A
u
t
h
o
r
i
t
y
H
a
v
i
n
g
J
u
r
i
s
d
i
c
t
i
o
n
.
Refer to specific installation standards.
3 The corrosIon-resistant coatings have passed the standard corrosion test
r
e
q
u
i
r
e
d
b
y
t
h
e
a
p
p
r
o
v
i
n
g
a
g
e
n
c
i
e
s
I
n
d
i
c
a
t
e
d
i
n
t
h
e
A
p
p
r
o
v
a
l
C
h
a
r
t
s
.
T
h
e
s
e
tests cannot and do not represent all possible corrosive environments.
P
r
i
o
r
t
o
i
n
s
t
a
l
l
a
t
i
o
n
,
v
e
r
i
f
y
t
h
r
o
u
g
h
t
h
e
e
n
d
-
u
s
e
r
t
h
a
t
t
h
e
c
o
a
t
i
n
g
s
a
r
e
c
o
m
-
patible with or suitable for the proposed environment For automatic s
p
r
i
n
k
l
e
r
s
,
t
h
e
c
o
a
t
i
n
g
s
I
n
d
i
c
a
t
e
d
a
r
e
a
p
p
l
i
e
d
t
o
t
h
e
e
x
p
o
s
e
d
e
x
t
e
r
i
o
r
s
u
r
f
a
c
e
s
only. Note that the spring Is exposed on sprinklers with Polyester,
P
T
F
E
,
a
n
d
E
N
T
c
o
a
t
i
n
g
s
.
For ENT coated automatic sprinklers, the waterway is coated
Sprinkler wrench 11
for recessed pe
sprinklers
-- A 1/2" ratchet Is
(not available fron
Carefully slide the wrench sideways around the protective cap, ensuring engagement wltP -01111111— the sprinkler wrench flats Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers
Form No. F033314 Rev 15.1
Page 401
NIKING® MICROFASTO QUICK
RESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hasting
s
M
l
49058 Telephone: 269-9454501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.co,
I Base Thread Sprinkler Slz Nominal Overall Listings and Approvals' Part SIN K.Factor Length (Refer also to Design Criteria.)
style Number' U.S. I metrIc' Inches mm cULus4 J VdS I LPCB I CJE7 I 12979 VK302 Pendent 1/2' 15mm 5.6 80.6 2-1/4 58 Al AIZ, BIV, D2. CZ X AIZ, SlY DIZ. CIV — D3Z - E - Product :rn1 Availability (ContactViking Office) 06662B VK302 Pendent 1/2 15mm 5.6 80.6 2-1/4 58 AIZ, B1Y. D2, C2X I — I — I — I — -
18021 VK302 Pendant 1/2' 15 mm 1 5.6 80.6 2-1/4 58 AIX, B1Y Al I AIX, BIY I DIX, CIV' I DIX, CIV' — Approved Temperature Ratings Approved Finishes Approved Escutcheons A -135 'F (57 'C), 155 'F (68 'C), 175 'F I - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 'C), 200 'F (93 'C). 286 'F (141 'C) Polyester", Black Polyes- Viking Micromatic Model E-I Recessed Escutcheon B -135 'F (57 'C). 155 'F (68 'C), 175 'F te,'.' V-Standard surface-mounted escutcheon or the (79 'C), and 200 'F (93 'C) 2- ENT' Viking Microfast Model F-I Adjustable Escutcheon, or recessed with the Viking Micro-
C - 155 'F (68 'C). 175 'F (79 'C), and 3-Chrome matic' Model E-1, E-2, or E-3 Recessed Escutcheon 200 'F (93 'C)
2- Standard surface-mounted escutcheon or the D -155 'F (68 'C). 175 'F (79 'C), 200 'F
Viking Microfast' Model F-I Adjustable Escutcheon (93'C),286'F (141 'C) 1
Footnotes tBase part number shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor measurement shown Is when pressure Is measured in Bar. When pressure is measured in kPe, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 'Listed by Underwriters Laboratories Inc. for use In the U.S. and Canada. 'cULus Listed as corrosion-resistant
'Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-I. EC-certificate of conformity 0832-CPD-2001. 'CE Certified, Standard EN 12259-1, EC-certlficates of conformity 0832-CPD-2001 and 0832-CPD-2003. 'MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-I 008.
cLJLus Listing Recuirements:
The Viking Microfast' Quick Response Pendent Sprinkler VK302
i
s
c
U
L
u
s
L
i
s
t
e
d
a
s
i
n
d
i
c
a
t
e
d
I
n
t
h
e
A
p
p
r
o
v
a
l
C
h
a
r
t
f
o
r
i
n
s
t
a
l
l
a
t
i
o
n
in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies.
'The sprinkler installation rules contained in NFPA 13 for stan
d
a
r
d
s
p
r
a
y
p
e
n
d
e
n
t
s
p
r
i
n
k
l
e
r
s
m
u
s
t
b
e
f
o
l
l
o
w
e
d
.
IMPORTANT: Always refer to Bulletin Form No. F_091699
- Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, Installation, and maintenance inform
a
t
i
o
n
.
V
i
k
i
n
g
s
p
r
i
n
k
l
e
r
s
a
r
e
t
o
b
e
i
n
s
t
a
l
l
e
d
i
n
a
c
c
o
r
-
dance with the latest edition of Viking technical data, the ap
p
r
o
p
r
i
a
t
e
s
t
a
n
d
a
r
d
s
o
f
N
F
P
A
,
L
P
C
B
,
A
P
S
A
D
,
V
d
S
or other similar organizations, and also with the provisions of g
o
v
e
r
n
m
e
n
t
a
l
c
o
d
e
s
,
o
r
d
i
n
a
n
c
e
s
,
a
n
d
s
t
a
n
d
a
r
d
s
,
whenever applicable.
Form No. F_033314 Rev 15.1
Page 5
N41KJW4J 8 MICROFAST® QUICK
RESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hasti
n
g
s
M
I
4
9
0
5
8
Telephone: 269-9454501 Technical Services: 877-3844464 Fax: 2694184680 Email: techsvcsviklngcorp.coi
Base Pad SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' Style ii1• BSP U.S. metrIc2 Inches mm (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2' I 15mm 5.6 80.6 2-1/4 58 AIZ, Bly, 02X, C2 !L.1t1' I:fYM!'l Limited Availability (Contact Local Viking Office) 06662B VK302 Pendant 1/2' 15 mm 5.6 80.6 2-1/4 58 AIZ, BIY, D2X, C2 18021 VK302 Pendent 1/2' 1 15 mm 5.6 80.6 2-1/4 1 58 AIZ, BIY
Approved Escutcheons Approved Temperature Ratings
X - Standard surface-mounted escutcheon or the A - 135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), 200 'F
Viking Micromatict Model E-1 Recessed (93 'C), 286 'F (141 'C) Approved Finishes Escutcheon B - 135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), and I -Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 'F (93 'C) and Black Polyester' Viking Microfast' Model F-I Adjustable Escutcheon,
C - 155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C), 286 2- EN15 or recessed with the Viking Micromatic' Model E-1 'F (141 'C)
or E-2 Recessed Escutcheon D - 155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C)
Z - Standard surface-mounted escutcheon or the
Viking Microfast" Model F-I Adjustable Escutcheon
Footnotes Base part number shown. For complete part number, refer to Viking'
s
c
u
r
r
e
n
t
p
r
i
c
e
s
c
h
e
d
u
l
e
.
2 Metric k-factor measurement shown Is when pressure is measured I
n
B
a
r
.
W
h
e
n
p
r
e
s
s
u
r
e
I
s
m
e
a
s
u
r
e
d
I
n
k
P
a
,
d
i
v
i
d
e
t
h
e
m
e
t
r
i
c
K
-
f
a
c
t
o
r
s
h
o
w
n
b
y
10.0.
'This table shows the FM Approvals available at the time of printing.
O
t
h
e
r
a
p
p
r
o
v
a
l
s
m
a
y
b
e
I
n
p
r
o
c
e
s
s
.
4 0ther colors are available on request with the same Approvals as the st
a
n
d
a
r
d
c
o
l
o
r
s
.
'FM approved as corrosion resistant.
FM Anoroval ReeuIrements
The Viking Microfast' Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-stora9e upright and pende
n
t
sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0).
F
M
G
l
o
b
a
l
L
o
s
s
P
r
e
v
e
n
t
i
o
n
D
a
t
a
S
h
e
e
t
s
c
o
n
t
a
i
n
g
u
i
d
e
l
i
n
e
s
r
e
l
a
t
i
n
g
t
o
,
b
u
t
not limited to: minimum water supply requirements, hydrauli
c
d
e
s
i
g
n
,
c
e
i
l
i
n
g
s
l
o
p
e
a
n
d
o
b
s
t
r
u
c
t
i
o
n
s
,
m
i
n
i
m
u
m
a
n
d
m
a
x
i
m
u
m
a
l
l
o
w
a
b
l
e
spacing, and deflector distance below the ceiling.
NOTE: The FM installation auldeilnes may differ from cULus an
d
/
o
r
N
F
P
A
c
r
i
t
e
r
i
a
.
IMPORTANT: Always refer to Bulletin Form No. F_09169
9
- Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance I
n
f
o
r
m
a
t
i
o
n
.
V
i
k
i
n
g
s
p
r
i
n
k
l
e
r
s
a
r
e
t
o
b
e
I
n
s
t
a
l
l
e
d
i
n
a
c
-
cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also wit
h
t
h
e
p
r
o
v
i
s
i
o
n
s
o
f
g
o
v
e
r
n
m
e
n
t
a
l
c
o
d
e
s
,
o
r
d
i
n
a
n
c
e
s
,
a
n
d
standards, whenever applicable.
Form No. F_033314 Rev 15.1
Page 6
N41KJW4j® MICROFAST® QUICK
RESPONSE PENDENT
SPRINKLER VK302 (K5.6)
The Viking Corporation, 210 N Industrial Park Drive, Hasti
n
g
s
M
l
4
9
0
5
8
Telephone: 269-945-9501 Technical Services: 877-384-
5
4
6
4
F
a
x
:
2
6
9
4
1
8
-
1
6
8
0
E
m
a
i
l
:
t
e
c
h
s
v
c
s
@
v
i
k
i
n
g
c
o
r
p
.
c
o
112"
(15 mm)
NPT.
2-114"
(57 (TIlT
-
'
M f
1-3/4"
(44.5 mm)
Installed with a standard
1/8" surface-mounted
escutcheon
Ceiling Opening Size:
2-511611(58.7 mm) minimum
2-112" (63.5 mm) maximum
2-118"
f(54mm)
2" (38 mm) (51 mm) Mm.
Installed with a Microfast Note: At maximum, adapter I Model F-I Adjustable exposed 112" (12.7 mm) Iron Escutcheon fees of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon
Ceiling Opening Size:
It
2-546" (58.7 mm) minimum
IN
2.1/2" (63.5 mm) maximum
2418" -2-118" -
94
(54
i 1418" 141811 1-31411 (44.5 mm) (28.6 mm)
(51 Min) (28.6 mm)Max. Max.
Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon
Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed
E
s
c
u
t
c
h
e
o
n
s
Form No. F_033314 Rev 15.1
(Added CCCF Approval)