HomeMy WebLinkAbout7315 ESTRELLA DE MAR RD; ; FPC2019-0055Co of PERMIT REPORT Carlsbad Print Date: 11/09/2023 Permit No: FPC2019-0055 Job Address: 7315 ESTRELLA DE MAR RD, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2165900500 Track #: Valuation: $116,275.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Fixed Extinguishing Syste Applied: 03/08/2019 Issued: 04/11/2019 0EV02092 Finaled Close Out: 04/13/2021 Final Inspection: INSPECTOR: Salcedo, Felix Fieri, Dominic Project Title: OMNI LA COSTA BALLROOM Description: OMNI LA COSTA RESORT - ANSUL FIRE SYSTEM FOR KITCHEN HOOD Applicant: FPContractor: EDISON FIRE EXTINGUISHER COMPANY INC EDISON FIRE EXTINGUISHER COMPANY INC STEVE VARGAS 3621 EAGLE ROCK BLVD 3621 EAGLE ROCK BLVD LOS ANGELES, CA 90065-3622 LOS ANGELES, CA 90065-3622 (323) 259-9999 (323) 259-9999 FEE AMOUNT FIRE Hood & Duct Extinguishing System Initial Sys $417.00 Total Fees: $417.00 Total Payments To Date: $417.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov R- 102 Restaurant Fire Suppression Manual SYSTEM DESIGN The ANSUL R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary AUTOMAN Release can be either an R-102 or a PIRANHA AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. Both systems must actuate simultaneously. Each system must be designed and installed per its appropri- ate manual. Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center-to-center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 in. (914 mm). When appliances are protectéd with R-102 nozzles, the hood and connecting duct above those appliances cannot be protected with PIRANHA nozzles. Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into 10 sub-sections: Nozzle Placement Requirements, Tank Quantity Requirements, Actuation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Station Requirements, Mechanical Gas Valve Requirements, Electrical Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quan- tity and piping requirements. Duct Protection - Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. SECTION 4— SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-1 GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (51-203 mm) into the center of the duct opening, discharging up. See Figure 4-1. 2-8 IN. (51 - 203 mm) FIGURE 4-1 000173 In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (203 mm) maximum, to a point just beyond the damper assembly that will not interfere with the damper. Exceeding the maximum of 8 in. (203 mm) in this way will not void the UL listing of the system. Previously listed three flow number and five flow number duct protection detailed in earlier published manual (Part No. 418087-06) can also still be utilized. DUCT SIZES UP 1050 IN. (1270 mm) PERIMETER! 16 IN. (406 mm) DIAMETER One 1W nozzle = one flow number 50 in. (1270 mm) perimeter maximum 16 in. (406 mm) diameter maximum [tC4SIZESUO 100 IN. (25ii)L I(ElMEEW13211N. (83m)IDLME) The chart below shows the maximum protection available from each duct nozzle. 3.0 Gallon 1.5 Gallon Description System System 2W Nozzle Maximum Maximum 100 in. (2540 mm) 100 in. (2540 mm) Perimeter Perimeter i Note: Ducts from multiple hoods connected to a common 1W Nozzle Maximum Maximum ductwork must be protected in compliance with NFPA 96 and 50 in. (1270 mm) 50 in. (1270 mm) all local codes. Perimeter Perimeter The A-i 02 system uses different duct nozzles depending on the size of duct being protected. FIGURE 4-9 R- 102 Restaurant Fire Suppression Manual Plenum Protection The R-102 system uses the 1W nozzle or the 1N nozzle for plenum protection. The 1W nozzle is stamped with 1W and the 1 N nozzle is stamped with iN, indicating they are one-flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. VERTICAL PROTECTION - GENERAL 1W NOZZLE - SINGLE AND 'V BANK PROTECTION One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft (0.6 m). After the first nozzle, any additional nozzles must be positioned at a maximum of 4 ft (1.2 m) apart down the entire length of the plenum. The plenum width must not exceed 4 ft (1.2 m). (The 1W nozzle can be used on single or V-bank filter arrangements.) See Figure 4-6. FIGURE 4-6 When protecting plenums with the 1W nozzle, two options of coverage are available: Option 1: The 1W nozzle must be on the center line of the single or V" bank filter and positioned within 1-20 in. (26-508 mm) above the top edge of the filter. See Figure 4-7. 20 IN. (508 mm) MAXIMUM 1 IN. (28 mm) MINIMUM 20 IN. (508 mm) MAXIMUM 1 IN. (26 mm) MINIMUM FIGURE 4-7 000199 SECTION 4— SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-5 Option 2: The 1W nozzle must be placed perpendicular, 8-12 in. (203-304 mm) from the face of the filter and angled to the center of the filter. The nozzle tip must be within 2 in. (50 mm) from the perpendicular center line of the filter. See Figure 4-8. MM) 4 IN (101 204 mm) IUM NOZZLE TIP MUST BE W THIS AREA FIGURE 4-8 000202 'HORIZONTAL PROTECTION - OPTION 1' )1N NOZZLE SINGLE BANK PROTECTION' One 1 N nozzle will protect 10 linear feet (3.0 m) of single filter bank, plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (50 to 102 mm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle (must be positioned 0-6 in. (0-152 mm) from the end of the hood to, the tip of the nozzle. See Figure 4-9. - 000201 R-102 Restaurant Fire Suppression Manual SECTION 4— SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-9 Fryer — Single Nozzle Protection (Continued) Maximum Area Dimensions — Single Nozzle Fryer Protection (Continued) Max. Size Max. Size Overall Type of Nozzle Height Frypot Only With Dnpboard Nozzle Above Top of Fryer 14.5 in. x 16.5 in. 14.5 in. x 26.5 in. 290 16 in. to 21 in. p (368 mm x 419 mm) (368 mm x 673 mm) (406 to 533 mm) 19.5 in. xl9in. 19.5 in. x25 3/8 in. 290 l3 in. tol6in. p (495 mm x 482 mm) (495 mm x 644 mm) (330 to 406 mm) 19.5 in. x 19 in. 19.5 in. x 25 3/8 in. 3N See Figure 4-18 ' (495 mm x 482 mm) (495 mm x 644 mm) S "18 18in.x18in: f l8 in. x273/4in. I ' 3N / 25 in. to35in. \ p457 mm x 457 mm), (457 mm x 704 mm), (635 mm to 889 mm Nozzle Location See Figure 4-17 See Figure 4-17 See Figure 4-18 See Figure 4-19 FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA ± 3 IN. (76 mm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND * 1 IN. (25 mm) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND AIMED AT THE MIDPOINT OF THE COOKING AREA. FIGURE 4-17 oum 34 IN. (863 mm) MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA 21 in. (534 mm) MINIMUM VERTICAL NOZZLE HEIGHT FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD SN NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 4-18 oomw mmio FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOTE: SN NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER. FIGURE 4-19 245 NOZZLE TIP LOCATION CENTER OF I COOKING SURFACE OR 11318 IN. (288 mm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY BURNER GRATE AREA 245 NOZZLE TIP LOCATION CENTER OF COOKING SURFACE OR 11 318 IN. (280 mm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY BURNER GRATE )+011 COOKING #1. AREA FIGURE 4-30 SECTION 4— SYSTEM DESIGN R- 102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-14 REV. 11 2014-SEP-01 'Range Protection 245 (2-Flow) Nozzle - High Proximity )Application No Obstructions '40 in. to 50 in. (1016 mm to 1270 mm) above the cooking surface. This high proximity application uses the 245 nozzle. The nozzle is stamped with 245 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 245 nozzle will protect a maximum cooking area of 672 in.2 (43354 mm2) with a maximum longest dimension of 28 in.) (711 mm). When using this nozzle for range protection, the nozzle must be pointed vertically down and positioned as shown in Figures 4-29 and 4-30. 245 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE 50 IN. (1270mm) MAXIMUM HEIGHT OF 245 NOZZLE TIP 40 IN. (1016 mm) MINIMUM HEIGHT OF 245 NOZZLE TIP FIGURE 4-29 NOTICE Four burner grates shown in Figure 4-30. For single or double burner grates, locate nozzle at center of cooking surface or 11 3/8 in. (288 mm) maximum from nozzle centerline to center of any burner grate. SECTION 4— SYSTEM DESIGN UL EX3470 ULC EX3470 PAGE 4-24 REV. 11 2014-SEP-01 Upright Broiler/Salamander Protection (Continued) UPRIGHT BROILER BROILER CHAMBER FRONT SIDE VIEW VIEW FIGURE 4-58 000252 'Gas-Radiant/Electric Char-Broiler Protections ) S The R-1 02 system uses the 1 N nozzle for gas-radianUe1ectric \char broiler protection. . The nozzle is stamped with a 1N, indicating that this is a one-flow nozzle and must be counted as one flow number. ,One 1 N nozzle will protect a hazard with a maximum length of 36 in. (914 mm) and a total cooking area which does not exceed 864 in.2 (55741 mm2). The nozzle tip must be located 15 in. to 40 in. (381 mm to 1016 mm) above the hazard surface. When using this nozzle for gas-radiant/electric char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at" the center of the cooking surface. See Figure 4-59a. 40 IN. (1016 mm) ' ' I MAXIMUM __ I 15 IN. (381 mm) MINIMUM FIGURE 4-59a R- 102 Restaurant Fire Suppression Manual Electric Char-Broiler Protection (Optional) The R-102 system uses the 1 N nozzle for electric char-broiler protection. The nozzle is stamped with a 1 N, indicating that this is a one-flow nozzle and must be counted as one flow number. One IN nozzle will protect a hazard with a maximum length of 34 in. (863 mm) and a total cooking area which does not exceed 680 in.2 (43870 mm2). The nozzle tip must be located 20 in. to 50 in. (508 mm to 1270 mm) above the hazard surface. When using this nozzle for electric char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking surface. See Figure 4-59b. 50 IN. (1270 mm) I ' I MAXIMUM N. (5 I , 20 IN. (508 I' II., !MINIMUM FIGURE 4-59b SECTION 4— SYSTEM DESIGN UL EX3470 ULC EX3470 PAGE 4-18 REV. 11 2014-SEP-01 NOTICE When using this type of griddle protection, only five flow numbers are allowed on a 1.5 gal (5.7 L) system and only 11 flow numbers are allowed on a 3 gal (11.4 L) system. fl ------ MIDPOINT OF 1 I I l III COOKING SURFACE + I Ill Ill I ill J I I 1 NOZZLE LOCATED ALONG COOKING ANY SIDE OF GRIDDLE SURFACE WITHIN SURFACE 0-2 IN. (0-50 mm) OFCOOKING EDGE SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. FIGURE 4-39 000241 I 1 NOZZLE LOCATION I' 0-2 IN. (0-50mm) f I INSIDE PERIMETER 40 IN. ....I 10- OF COOKING SURFACE I I (1016 mm) I I MAXIMUM /) HEIGHT OF 1N I NOZZLE TIP I / ,' I 35 IN. (889 mm) / / 1IMINIMUM HEIGHT EDGE 0F 04 COOKING II SURFACE i_j I, I II OF 1N I I NOZZLE TIP ' FIGURE 4-40 000243 R-102 Restaurant Fire Suppression Manual Griddle Protection 290 (2-Flow) Nozzle - High Proximity Application Option I - Nozzle Center Located 30 in. to 50 in. (762 mm to 1270 mm) above the cooking surface. This high proximity application uses the 290 nozzle. The nozzle is stamped with 290 indicating this is a 24low nozzle and must be counted as two flow numbers. One 290 nozzle will protect a maximum cooking area of 720 in.2 (46451 mm2) with a maximum dimension of 30 in. (762 mm). When using this nozzle for high proximity applications, the nozzle must be positioned within 1 in. (25 mm) of the center of the cooking surface and pointed vertically down. See Figure 4-41 and 4-42. CENTER LINE OF GRIDDLE SURFACE* 1 IN. (25 mm) IN ANY DIRECTION 50 IN. (1270 Mm) MAXIMUM HEIGHT 0F290 f N TIP 30 IN. (762 mm) MINIMUM HEIGHT OF 290 NOZZLE TIP FIGURE 4-41 AREA NOZZLE I IN. 25 mm) LCN - ::[r MAXIMUM )KING + 1 IN. (25 mm) MAXIMUM CENTER OF GRIDDLE SURFACE OR A MAXIMUM DIMENSION OF 20.6 IN. (523 mm) FROM NOZZLE CENTERLINE TO FURTHEST CORNER OF GRIDDLE FIGURE 4-42 000773 I AIM POINT (DIAGONAL CENTER OF MODULE I COOKING AREA) RIGHT-TO-LEFT CENTERLINE AIM POINT ( DIAGONAL CENTER OF MODULE COOKING AREA) RIGHT- TO-LEFT CENTER- LINE R- 102 Restaurant Fire Suppression Manual SECTION 4— SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-11 (Continued) Maximum Area Dimension - Multiple Nozzle Fryer Protection Max. Size Module Max. Size Module Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location Full or Split Vat Full or Split Vat 21 in. x 210 in.2 21 in. x 294 in.2 230 27 in. to 47 in. See Figure 4-21 (533 mm x 0.14 m2) (533 mm x 0.19 m2) (686 mm to 1194 mm) Full or Split Vat Full or Split Vat 21 in. x 210 in.2 21 in. x 294 in.2 245 20 in. to 27 in. See Figure 4-21 (533 mm x 0.14 m2) (533 Mm x 0.19 m2) (508 mm to 686 mm) Full or Split Vat Full or Split Vat 21 in. x 210 in.2 21 in. x 294 in.2 290 13 in. to 16 in. See Figure 4-22 (533 mm x 0.14 m2) (533 Min x 0.19 m2) (330 mm to 406 mm) 25 3/8 x 370.5 in2 253/8 x 495 in2 290 13 in. to 16 in. See Figure 4-22 (644 mm x 0.24 m2) (644 mm x 0.32 m2) (330 mm to 406 mm) Full or Split Vat Full or Split Vat 26 1/2 in. x 203 in.2 26 1/2 in. x 384 1I4 in.2 290 16 in. to 27 in. See Figure 4-22 (673 mm x 0.13 m2) (673 mm x 0.25 m2) (406 mm to 686 mm) 25318 x 370.5 in2 253/8 x 495 in2 3N See Figure 4-23 See Figure 4-23 (644 mm x 0.24 m2) (644 mm x 0.32 m2) 273/4 x 324 in.2 374T49I See Figure 4-24 (704 mm x 0.21 m2) (704 mm x 0.32 m2) 635 mm to 889 mm) 34 IN. (864 mm) MAXIMUM DIAGONAL BETWEEN NOZZLE CENTER I RD AREA FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD POSITION NOZZLE TIP ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE MODULE IT IS PROTECTING AND AIM AT THE MIDPOINT OF THAT MODULAR AREA. FIGURE 4-21 FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE MODULAR if IS PROTECTING AND AIMED AT THE MIDPOINT OF THAT RESPECTIVE MODULE AREA. FIGURE 4-23 21 In. (533 MINIMUM VERTICAL NOZZLE HEIGHT FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE RESPECTIVE MODULAR AREA ± 3 IN. (76 mm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE MODULE AND * 1 IN. (25 mm) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE MODULE AND AIMED AT THE MIDPOINT OF THE MODULE. FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD THE 3N NOZZLE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE PERIMETER AND FORWARD OF THE RIGHT-TO-LEFT CENTERLINE OF THE COOKING AREA. THE AIMING POINT OF THE NOZZLE MUST BE AT THE DIAGONAL CENTER OF THE MODULAR COOKING AREA. FIGURE 4-22 FIGURE 4-24 SECTION 4— SYSTEM DESIGN R- 102 Restaurant Fire Suppression Manual UL EX3470 ULC EX3470 PAGE 4-12 REV. 11 2014-SEP-01 Multiple Nozzle Fryer Protection — Tilt Skillet I Braising Pan Protection for tilt skillets or braising pans is to be based upon the coverage limitations provided for deep fat fryer protection. Refer to Section IV, DESIGN, starting on Page 4-10, for maximum fryer nozzle coverages and maximum fryer nozzle height limitations. Although the maximum 864 in.2 (55741 mm2) total surface cooking area requirement applies to fryer protection, it does not apply to tilt skillets or braising pans. Each tilt skillet/braising pan protected module must not exceed the fryer limitations for "MAXIMUM SIZE MODULE OVERALL WITH DRIPBOARD" coverage per nozzle as described in Table on Page 4-11. Tilt skillets and braising pans generally utilize a hinged cover. Fryer protection nozzles are to be placed toward the front of the appliance to minimize the potential for the tilt skillet or braising pan cover to interfere with the nozzle discharge. See Figures 4-25 and 4-26. COVER MUST NOT INTERFERE WITH NOZZLE DISCHARGE COVER MUST NOT INTERFERE WITH EDGE OF DISCHARGE PATTERN FOR MINIMUM AND MAXIMUM NOZZLE HEIGHTS, REFER TO FRYER NOZZLE FRYER NOZZLE USED FOR TILT SKILLET OR BRAISING PAN PROTECTION MUST BE POSITIONED NEAR THE FRONT EDGE OF THE PAN AND AIMED AT ThE FRONT TO BACK CENTERLINE OF THE PAN. THE DISCHARGE FROM THE NOZZLE(S) MUST COMPLETELY CLEAR THE PAN COVER WITH AN UNOBSTRUCTED VIEW TO THE BACK OF THE PAN. FIGURE 4-26 / >' oo1I THE NOZZLE IS TO BE PLACED TOWARD THE FRONT OF THE APPLIANCE TO MINIMIZE THE POTENTIAL FOR THE SKILLET OR BRAISING PAN COVER TO INTERFERE WITH THE NOZZLE DISCHARGE. FIGURE 4-25 R- 102 Restaurant Fire Suppression Manual TANK AND CARTRIDGE REQUIREMENTS Once the hazard analysis is completed and the total nozzle flow numbers are established, the quantity and size of agent tanks and cartridges needed to supply the nozzles with the proper volumes of agent at the proper flow rates can be determined. For cartridges used in the regulated release mechanism, flow capacities, tank quantities and sizes, and regulated release cartridge options are given in the table below. Total Quantity and Regulated Release Flow Size of Cartridge Options Numbers* Tank(s) Nitrogen Carbon Dioxide 1- 5 (1) 1.5 Gallon LT-20-R 101-10 6-11 (1) 3.0 Gallon LT-30-R 101-20 11-16 (1) 1.5 Gallon Double 101-30 (1) 3.0 Gallon 16-22 (2) 3.0 Gallon Double 10130** 16-22 (2) 3.0 Gallon Double - (Manifold) [2233J ((3)l3TolGallon tDIëi - When one or more regulated actuators are used, the following tank and cartridge combinations apply for each regulated actu- ator: Regulated Actuator Regulated Actuator Tank(s) Cartridge (1)1.5 Gallon LT-20-R or 101-10 (1) 3.0 Gallon LT-30-R or 101-20 (1)1.5 Gallon and LT-A-101-30 or 101-30** or 3.0 Gallon double tank 3.0 Gallon LT-A-101-30 or 101-3V or double tank (2) 3.0 Gallon (Manifold) LT-A-101-30 or Double (3) 3.0 Gallon LT-A-101-30 or Double * For exceptions to maximum flow numbers, we Distribution Piping Requirements for 1.5 gallon and 3.0 gallon systems In this Section. The 101-30 cartridge can not be used when two 3.0 gallon tanks are manifolded together. SECTION 4— SYSTEM DESIGN UL EX3470 ULC EX3470 2014-SEP-01 REV. 11 PAGE 4-61 For higher total flow numbers (23 to 110), multiple cartridges and regulated actuators are required as shown in the System Selection Guide in "Appendix7 Section ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS This section contains the guidelines for installing the actuation and expellant gas lines between the regulated release mech- anism regulator, each regulated actuator regulator, and each agent tank. These limitations should be considered when select- ing the component mounting locations. The actuation gas line is the length of pipe and/or hose that is run from either the AUTOMAN Regulated Release Assembly or the Remote Release Assembly that directs high pressure from the cartridge in the release to actuate one or more additional Regulated Actuator Assemblies. The actuation gas line can consist of 1/4 in. Schedule 40 black iron, chrome-plated, stain- less steel, or galvanized steel pipe and fittings, and/or factory supplied stainless steel braided actuation hose. The expellant gas line is the length of pipe that is run from the regulator in either the AUTOMAN Regulated Release Assembly or a Regulated Actuator Assembly that directs regulated pres- sure to the agent storage tanks to pressurize the tank and discharge the agent. The expellant gas line shall consist of 1/4 in. Schedule 40 black iron, chrome-plated, stainless steel, or galvanized steel pipe and fittings. Actuation Gas Line —6 to 8* Tanks Maximum * 8 Tank maximum reflects the utilization of 3 tank regulated actuators. Use only 1/4 in. Schedule 40 black iron, hot-dipped galva- nized, chrome-plated, or stainless steel pipe and fittings. The actuation gas line piping is installed from the regulated release mechanism to each regulated actuator connected within the system. The total length of the actuation gas line from the regulated release assembly to the regulated actua- tor assembly(ies) must not exceed 20 It (6.0 m) when using an LT-20-R, an LT-30-R nitrogen cartridge, or a 101-10 or a 101-20 carbon dioxide cartridge. See Figure 4-121. REGULATED ACTUATOR ASSEI EXPELLANT GAS LINES NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS ACTUATION GAS LINE WITH AN LT-20-R, LT-30-R, 101-10 OR 101-20 CARTRIDGE MAXIMUM LENGTH OF 20 FT (6.0 m): MAXIMUM NO. OF FITTINGS 9 AUTOMAN REGULATED RELEASE ASSEMBLY FIGURE 4-121 000fl5 U ANSULS 9 1 It is hereby certified that Steve Vargas of /Certificate of / Training Edison Fire Extinguisher Company Los Angeles has successfully completed the training course R-102 Restaurant Fire Suppression System- Design, Installation, Recharge & Maintenance Training Hrs: 16 Training Date: November 16, 2016 Expiry Date: November 16, 2019 Mark E. Fessenden Director, Services -Americas Tyco Fire Protection Products tqc17 Flie Protection Products Copyright 0 2016Tyco Fire Protection Products LR All rights reserved.