HomeMy WebLinkAbout2525 EL CAMINO REAL; ; FA13004011/9/23, 1:28 PM FA130040 Permit Data City of Carlsbad Fire Alarm Permit 2525 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 1563020900 Lot #: 0 Permit No: FA130040 Status: PENDING Applied 6/6/2013 Approved: Reference No.: Issued: PC #: Inspector: Project Title: AUDEO CHARTER SCHOOL TI INSTALL NEW 4006 FIRE ALARM PANEL, SMOKE DETECTOR, PULL STATION, & NOTIFICATION. SPRINKLER SYSTEM IS MONITORED BY THE MALL FIRE ALARM SYSTEM. Applicant: SIMPLEX GRINNELL 3568 RUFFIN ROAD SAN DIEGO CA 858-633-9100 Owner: PLAZA CAM INO REAL C/O WESTFIELD PROPERTY TAX DEPT P.O BOX 130940, DEPT WFLD CARLSBAD, CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 286 0 .286 0 about:blank 1/1 tqco /Fire & / SimplexGrinnell Security July 31, 2013 SimplexGrinnell 3568 Ruffin Road Audeo Charter School— Plan Review San Diego, CA 92123 Cindy Wong Phone (858) 633-9100 City of Carlsbad Fire Department Fax (858) 633-9101 1635 Faraday Ave Carlsbad, CA 92008 Re: Response to Comments on 07-19-2013 Smoke detection added to entire tenant space with exception to small storage rooms. The water flow is tied in. Fully automatic system with smoke detection and sprinkler detection, monitored, activated, and reset from the main FACP in the security office. Fully automatic system with smoke detection and sprinkler detection, monitored, activated, and reset from the main FACP in the security office. Note added to Operations Matrix. Plans and products have all changed part numbers and quantities have increased. Calculations have been altered. The highlighted Revi product copy has the current draws highlighted. Sincerely, Douglas Daniels Design Engineer SimplexGrinnell San Diego RE CEJ%9 AU Ol 2OI Pmj bEPAfd FILE COpy tyco / Fire & / SimplexGrinnell I Security I SirnplexGrinnell LP 3568 Ruffin Road San Diego, CA 92123 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com PROJECT: FIRE ALARM PRODUCT SUBMITTAL I Mui3 0 12013 CAftLsi. FIRE DEPARTMENT Westfie I AUDEO Charter School 2525 El Camino Real Space 252 Carlsbad, CA 92008 8/1/2013 PROJECT #: rA 13 o ô - tqcci /Fire & / SimplexGrrnnell Security SimplexGrinnell LP 3568 Ruffin Road San Diego, CA 92123 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com ITEM MODEL NO. DESCRIPTION A 4010-9402 4010ES FACP B 2081-9288 12.7 Amp/Hour Batteries C 4098-9792 Addressable Detector Base 4098-9714 Photo sensor D 4099-9001 Pull Station E 4906-9101 Strobe Multi-cd F 4906-9140 Horn/Strobe Hi-cd G 4090-9001 Supervised lAM 4090-9002 Relay lAM 4090-9101 Monitor lAM H 2190-9163 Control ZAM C.S.F.M. NO. 7165-0026:369 N/A 7300-0026:217 7272-0026:218 7150-0026:224 7125-0026:316 7125-0026:333 7300-0026:223 7300-0026:223 7300-0026:223 7300-0026:182 8/1/2013 REV.#: 1 PROJECT#: !3Sim plEx UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Basic system includes: Capacity for up to 248 addressable devices, up to 127 VESDA SLI points, up to 2000 points of Annunciation and up to 20 internal and external card addresses Color-coded operator interface with membrane keypad includes 2 x 40 Super-twist LCD display, 3 programmable control keys and 6 programmable LEDs CPU assembly includes dedicated compact flash memory for on-site system information storage and convenient Ethernet service port access 8 A power supply with up to 2 A of Auxiliary power and battery charger capacity for up to 110 Ah batteries (UL) or up to 50 Ah batteries (ULC) (33 Ah max in control panel cabinet) 4 on-board Class A or B, 3 A NACs and one programmable auxiliary relay output rated for 2 A @ 32 VDC Class A or B Two-loop Isolated IDNet Communications (lDNet+) supports up to 248 addressable and analog sensing devices on non-twisted, non-shielded wiring Remote annunciator module support via RUI (remote unit interface) communications port, supports either Class B (Style 4) or X (Style 7) Pathway operation 48 LED panel mount annunciation provides 40 Red and 8 Yellow pluggable LEDs (select models, meets ULC requirements), optional LED kits are available for custom LED configurations Optional Main System Supply and door mounted modules include: City Connect (with or without disconnect switches) Alarm Relay Module Truelnsight Remote Gateway Optional block space modules include: Fire Alarm Network Interface Card for 4120/4100 Peer-to-Peer network communications, supports either Class B or X (Style 7) Pathway operation Ethernet connectivity options include Building Network Interface Module (BNIC) and SafeLINC Internet Interface Dual RS-232 Module (for printer, PC annunciator or third party interface) VESDA Air Aspiration High Level Interface Serial DACT 8 Zone IDC Modules Class A or B 4 Point Auxiliary Relay Module 40I0 Fire Control Panels Addressable Fire Detection and Control Basic Panel Modules and Accessories 401OES Fire Alarm Control Panel with or without LED Annunciation Compatible with Simplex® remotely located: 4098-9757 QuickConnect 2 and legacy 4098-9710 QuickConnect lrueAlarm smoke sensors 4003EC Small Voice Panels 4009 IDNet NAC Extenders 4009 TrueAlert Addressable Controllers and TrueAlert Power Supplies (TPS) 4081 Series, II 0Ah Battery Chargers 4100-7400 Series Graphic Annunciators 4190 PC Annunciator 4190 Fiber Modems and Physical Bridges 4606-9102 Remote LCD Annunciator and 4100-9400 Series Remote InfoAlarm Command Centers IP communicator compatibility 40I0ES Agency listings: UL Std. 864, Fire Detection and Control (UOJZ), and Smoke Control Service (UUKL), and Releasing Service (SYZV) UL Std. 2017, Process Management Equipment (QVAX) UL Std. 1076, Proprietary Alarm Units-Burglar (APOU) UL Std. 1730, Smoke Detector Monitor (UULH) ULC Std. S527-99, Fire Detection and Control (UOJZC) ULC Std. S559-04, Supervising Station (DAYRC) * See pages 5 and 6 for add/tonal listing information. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:0369 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. NYC Fire Dept COA #6095. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4010-0004-4 4/2012 di i rt Ic 401 OES Series Fire Detection and Control Panels provide leading edge installation, operator, and service features for customer applications in the mid-range addressable fire alarm systems market. An on-board Ethernet port provides fast external system communications to expedite installation and service activity. Dedicated compact flash memory archiving provides secure on-site system information storage of electronic job configuration files to meet NFPA 72 (National Fire Alarm and Signaling Code) requirements. Modular design. A variety of functional modules are available to meet specific system requirements. Selections allow panels to be configured for either Stand-Alone or Networked fire control operation. I I I L1 • . r.i 1• i'er.i i The Master Controller and Main System Supply are mounted in the upper section of the 4100ES cabinet. 40I0ES Block Space Option Cards mount to the left of the 4010ES Main System Supply. There are 3 available 4" x 5" blocks for mounting 40I0ES hardware options. Other 40IOES Options: The 4010E5 City Connect module or the optional Alarm Relay module mount directly to the Main System Supply. These options are mutually exclusive. Network Media modules mount directly to the 401OES Network Interface Card. The Truelnsight Remote Gateway mounts on the back side of the 401OES User Interface Panel. The Battery Compartment located in the bottom of the 4010ES cabinet accepts two batteries, up to 33 Ah, without interfering with expansion module space. The illustrations below identify mounting locations available for optional 40IOES modules. 3 available 4" x 5' block spaces for additional option cards Mai Spy-, Block A Supply Bb0B Block Truelnsight Remote Gateway mounts on the back of the 4010ES User Interface Panel Mounting Locations for Optional Modules nii rii.i*irPt1 Mounting box provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required The hinged User Interface panel easily opens for internal access Modules are power-limited (except as noted, such as relay modules) Doors include tempered glass inserts, boxes and doors are available in platinum or red Box and door/retainer assemblies are included with Basic Panel assemblies Software Feature Summary TrueAlarm individual analog sensing with front panel information and selection access "Dirty" TrueAlarm sensor maintenance alerts, service and status reports including "almost dirty" TrueAlarm magnet test indication appears as distinct "test abnormal" message on display when in test mode TrueAlarm sensor peak value performance report "Install Mode" allows grouping of multiple troubles for uninstalled modules and devices into a single trouble condition (typical with future phased expansion); with future equipment and devices grouped into a single trouble, operators can more clearly identify events from the commissioned and occupied areas Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring "Recurring Trouble Filtering" allows the panel to recognize, process, and log recurring intermittent troubles (such as external wiring ground faults), but only sends a single outbound system trouble to avoid nuisance communications WALKTEST silent or audible system test performs an automatic self-resetting test cycle S4010-0004-4 4/2012 Convenient and extensive operator information is provided using a logical, menu-driven display Multiple automatic and manual diagnostics for maintenance reduction Convenient PC programmer label editing Password access control Alarm and Trouble History Logs (up to 2000 total events) are available for viewing from the LCD, or capable of being printed to a connected printer, or downloaded to a service computer Convenient Status Information. With the locking door closed, the glass window allows viewing of the display, status LEDs, and available operator switches. Features include a two-line by 40-character, wide viewing angle (super-twist) LCD with status LEDs and switches as shown in the illustration below. LED indicators describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to the control switches and allows further inquiry by scrolling the display for additional detail. The following illustration identifies the primary functions of the operator interface. ULC SYSTEMS 6 SYSTEM STATUS INDICATOR LEDs provide require designating system status indications, LEDs flash to indicate a Ground Fault a change in status and remain on-steady after indicator I acknowledged until reset FIRE ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts PRIORITY 2 ACK acknowledges a Priedty 2 Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts TROUBLE ACK acknowledges system trouble conditions, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts ALARM SILENCE causes audible notification appliances to be silenced (depending on panel programming) typically after evacuation is complete and while alarm source is being investigated: may allow visible notification to continue (strobes still flashing) SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal 3 PROGRAMMABLE LEDs two selectable as Red or Yellow, one selectable as Green or Yellow (Custom label insertj 2 X 40 LCD READOUT, LCD is backlighted during normal conditions, provides up to 40 characters for custom label information FIRST ALARM DISPLAY operation can be selected for maintained display of first alarm until acknowledged 'T' IU9A'_ rin WaterfiowEastil 12: 25:l5 ALARMS WARNINGS IRE PRIORITY 2 SUPERVISORY TROUBLE ALARM AC SILENCED POWER i='~~JL~7] ry~ L8 J L~qj O.Simplex RrE Control 40101~ 3 PROGRAMMABLE POINT STATUS ADDITIONAL FUNCTION LCD NAVIGATION INUMERIC KEYPAD for FUNCTION SWITCHES CONTROL KEYS: KEYS: CONTROL: point category and point with yellow LED Point Enable and Event Time Request Menu selection selection (alphabet indicators Disable More Information Request Vertical and I characters are not used at Force On or Arm Lamp Test Horizontal position this time) Force Off or Disarm selection buttons Return On/Off or Arm/Disarm to Auto Mode S4010-0004-4 4/2012 The 4010ES is compatible with an extensive list of remote peripheral devices including printers, PC Annunciators and both conventional and addressable devices including TrueAlarm analog sensors. Overview. The 4010ES provides standard addressable device communications for IDNet compatible devices. Using a two wire communications circuit, individual devices such as manual fire alarm stations, TrueAlarm sensors, conventional IDC zones, and sprinkler waterfiow switches can be interfaced to the addressable controller to communicate their identity and status. Addressability allows the location and condition of the connected device to be displayed on the operator interface LCD and on remote system annunciators. Additionally, control circuits (fans, dampers, etc.) may be individually controlled and monitored with addressable devices. Addressable Operation. Each addressable device on the communication channel is continuously interrogated for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Both Class B and Class A pathway operation are available. Sophisticated poll and response communication techniques ensure supervision integrity and allow for "T-tapping" of the circuit for Class B operation. Devices with LEDs pulse the LED to indicate receipt of a communications poll and can be turned on steady from the panel. lDNet+ Channel Capacity. The Main System Supply provides an lDNet+ signaling line circuit (SLC) that supports up to 248 addressable monitor and control devices intermixed on the same pair of wires. lDNet+ Communications wiring specifications. lDNet+ circuits may be run on NEC 760 untwisted pair, twisted pair, or shielded twisted pair conductors. lDNet+ Wiring Specifications Size 18 AWG (0.82mm2 ) T Type NEC 760 Wire (untwisted, twisted, or shielded twisted pair) Farthest Distance 126-248 Up to 2500 feet (762 m) from Control Panel Upto4000ft(1219m) per Device load up to 125 Up to 12,500 ft (3.8 km) Total Wire length Allowed Class Note: The sum of line-to-line A or Class B, including'T-taps" capacitance plus the capacitance for Class B wiring (total for both of either line-to-shield (if shield is isolated circuits combined) present) = 0.6 UF maximum (total for both isolated circuits combined) * Other circuits may reauire shielded winna. Review your system with your local Simplex product supplier. TrueAlarm System Operation Addressable device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke obscuration (shown directly in percent) or for specific heat detection levels. To evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read and compared to the alarm threshold directly in percent. CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address. The CO sensor can be enabled/disabled, used in LED/Switch modes and custom control, and can be made public for communication across a fire alarm Network. (refer to data sheet S4098-0041 for details) TrueAlarm heat sensors can be selected for fixed temperature detection, with or without rate-of-rise detection. Utility temperature sensing is also available, typically to provide freeze warnings or alert to HVAC system problems. Readings can be selected as either Fahrenheit or Celsius. TrueSense Early Fire Detection. Multi-sensor 4098-9754 provides photoelectric and heat sensor data using a single 40IOES lDNet address. The panel evaluates smoke activity, heat activity, and their combination, to provide TrueSense early detection. For more details on this operation, refer to data sheet S4098-0024. Diamnostics and Detault Device I vne Sensor Status. TrueAlarm operation allows the control panel to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor. CO Sensors track their 5 year active life status providing indicators to assist with service planning. Indicators occur at: 1 year, 6 months, and when end of life is reached. Modular TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific location requirements. This allows intentional sensor substitution during building construction when conditions are temporarily dusty. Instead of covering smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. The control panel will indicate an incorrect sensor type, but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. S4010-0004-4 4/2012 Irn'T',lnh(ui&I1I The 40I0ES Master Controller includes dedicated 2GB compact flash Mass Storage memory for on-site system information storage and convenient Ethernet service port access Convenient front panel accessed Ethernet port for quick and easy download of site-specific programming AND, firmware enhancements are made via software downloads to the on-board flash memory Every downloaded job is automatically stored to Compact flash without overwriting earlier versions providing a means for recovering previous configurations Downtime is reduced because the system stays running during download I:flr1ITIIi*i.iiF4lrITU 4010ES panels include: an Operator Interface, Master Controller with 2GB Compact Flash, Class A or B Two- loop Isolated IDNet Communications (1DNet+) supporting up to 248 addressable and analog sensing devices, 8 A power supply with up to 2 A of auxiliary power, 110 Ah (UL)/ 50 Ah (ULC) battery charger (33 Ah maximum in the control panel cabinet), 4 Class A or Class B NACs rated @ 3 A each for Special Application and 2 A for Regulated 24 DC operation, I programmable auxiliary relay rated for 2 A @ 32 VDC, I RUI Class B or X communications port for remote annunciation devices, cabinet, and door. Support is for up to 20 internal and external card addresses. Other standard options may be provided depending on model (see basic panel model selection below for additional details on specific models). Modifications can be uploaded as well as downloaded for greater service flexibility I'iIIli(IlI1hIejfj1' Mass Storage allows job specific files to be store in The Main System Supply provides the power source and the control panel such as test and inspection reports, the Input/Output connections for the basic 40IOES panel. record drawings, specifications, and more... The main features are listed in the Basic Panel description Ethernet connectivity options include Building below. Network Interface Module (BNIC) and SafeLINC Internet Interface RUI (remote unit interface) communications port supports either Class B or X Pathway operation for remote annunciation equipment and for 4009 lrueAlert Controllers and TrueAlert Power Supplies Basic Panel Model Selection Note: Supervisory and Alarm current specifications are for determining battery standby requirements. Current specifications consider no load on addressable channels (see addressable device load specifications for device load battery standby), RUI channel active, and 24 of 48 LEDs active (for 48 LED models) Model Panel Language Listings gs Features Supv. Alarm Available Option Color & Voltage Current Current Blocks 4010-9401 Red Basic panel with 2x40 LCD Operator English UL, CSFM, FM, Interface and (1) Two-loop Isolated lDNet+ 39 120 VAC NYC Fire Dept Channel, Class A or B, with support for up to 40 iPlatinum 248 addressable devices 4010-9403 Red English UL, ULC, CSFM, FM, 3 4x5" 4010-9404 Platinum 120 VAC NYC Fire Dept blocks Same features as above with 48 LED 336 mA 455 mA 4010-9405 Red annunciation French 120 VAC FM ULC, CSFM, 4010-9406 Platinum S4010-0004-4 4/2012 VTi* *11F1 '1 IF I Ib11IT1 Mill 1:flW11III T I1 Addressable Supervisory Alarm Channel De 0C V I e Load'. Current Current With 248 Devices Add 199 mA 288 mA Main System SUPPlY With 125 Devices Add 100 mA 165 mA With 50 Devices Add 40 mA 90 mA Block Space Option Card Selection Note: Refer to diagram on page 2 for Option Module availability. Supervisory and Alarm current specifications are for determining battery standby requirements. Current specifications consider no load on addressable channels (see addressable device load specifications for device load battery standby), RUl channel active, and 24 of 48 LEDs active (for 48 LED models) Single Block Option Modules, Select Three (3) Maximum if No Dual Block Module is Selected; Select One (1) Maximum if a Dual Block Module is Selected Model Features Option Block Usage Supervisory Current Current 1 Block 071ö92I Serial DACT (must mount in block D under main system supply) 4010-9908 4 Point Aux Relay Module I Block 15 mA 60 mA Voltage Regulator Module, 22.8 to 26.4 VDC 4.9A 4010-9916 (25 VDC nominal); isolated and resettable output; 1 Block 3 A maximum maximum includes earth detection circuit and trouble relay for with 2.5 A load with 4 A load status monitoring 4010-9918 Dual RS232 Module 1 Block 60 mA 60 mA 4010-9901 VESDA HLI I Block 60 mA 60 mA Dual Vertical Block (Flat) Modules, Select One (except for Media Cards) Model Features Option Block Usage Supervisory Alarm Current Current 4010-9922 Modular Network Interface Card 2 Vertical Blocks 30 mA 30 mA (requires two media modules, see below) 4010-9818 Network Media Card Wired N/A (mounts to 4010-9922) 55 mA 55 mA 4010-9819 Network Media Card Fiber Optic 25 mA 25 mA 4010-9914 Building Network Interface Card 2 Vertical Blocks 236 mA 236 mA 40109913* SafeLINC Internet Interface 2 Vertical Blocks 115 mA 115 mA Dual Vertical Block (Slot) Modules, Select One if no Dual Vertical (Flat) Modules from Above are Selected Model Features J I Option Block Usage supervisory Alarm Current Current 4010-9920 I 8 Zone Initiating Device Circuit- Class B I 2 Vertical Blocks 75 mA 195 mA 4010-9921 8 Zone Initiating Device Circuit - Class A (mother/daughter card) * UL/ULC Listed only Additional Panel Option Selection (block space is not used) Model Features Supervisory Current Alarm Current Mounting Requirements 4010-9909 City Connect Module w/ disconnect switches 20 mA 36 mA Select one maximum, mounts 4010-9910 City Connect Module 20 mA 36 mA on Main System Supply 4010-9911 Alarm Relay Module 15 mA 37 mA 40109919* Truelnsight Remote Gateway 62 mA 62 mA Mounts on Front Door 4100-5128 Battery Distribution Terminal Block, mounts to side of box, required when battery connection leaves the 401OES box (also used in the 4100ES fire alarm control panel) * Refer to data sheet S4100-0063 and contact your local Simplex product representative for more details 6 S4010-0004-4 4/2012 Cabinet Dimension Reference Front view, cabinet outline without door Side view with door attached Il 16" (406 mm) Pip! Total depth, _ box and door 11-11/16' _____ (296 mm) = 4- Box depth, - 6-29/32 _______ (175 mm) / - - Exposed cabinet for Use 4 holes to semi-flush mounting - - - Secure box to wall j 1-3/8" (35 mm) minimum 22" (559 mm) Stud alignment Exposed door and cabinet., markers, each side for semi-flush mounting 6-1/8" (156 mm) minimum 6"stiJ ----------------------------------- Reserved for Batteries Door thickness 4-3/4(121 mm) - \ 4" stud 4_24" (610 mm) Miscellaneous Accessories LED Kits Model Description 4100-98 1 8 Yellow LED Kit 4100-9844 8 Green LED Kit 4100-9845 8 Red LED Kit 4100-9855 8 Blue LED Kit End User Programming Tools Model 4100-8802 Description End User Programming Unit Software 4100-0292 Custom Label Editing (USB Dongle) 4100-0295 Port Vectoring Setup and Control (USB Dongle) 4100-0296 User Group / Passcode Editing (USB Dongle) 4100-0298 WalkTest Configuration Setup and Control (USB Dongle) 401 OES Factory Programming Model Description 4010-8810 4010ES Factory Programming 4010-0831 Custom Label and Panel Programming 7 S4010-0004-4 4/2012 40I0ES Card Address Allocation The 40I0ES has a maximum Internal and External Card Address Limit of 20 Card Addresses. Use the Table below to calculate 40I0ES card address allocation. INSTRUCTIONS: Below is a list of 401OES equipment and the quantity of card addresses they consume For the applicable control panel, write in the Card Address Consumption value in the Card Address Allocation column. (Note: Only select 1 control panel) For the option cards to be installed on the 4010ES, write in the Card Address Consumption value in the Card Address Allocation column. Total the Card Address Allocation column (total must not exceed 20). PID Description: :. •. =.Card Addres5es Consumption Card Address Notes Allocation Control Panels (Select One) 4010-9401.-9402 IWO Display. Single lDNet Channel. Single Bay Box 2 4010-9403,-9404, 9405. or -9406 2x40 Display. Single IDNet Channel, 48 Pluggable LED Module 4010-9405 & -9406 Canada only Panel Option Cards (Select As Required) 4010-9901 Flat Vesda HLI 1 4010-9922 Flat Network Card 1 4010-9908 4 Point Flat Aux Relay Module 1 4010-9912 Serial DACT 1 4010-9913 SafeLinc Internet Interface 1 4010-9914 Building Network Interface Card 1 4010-9918 Dual R5232 Module 1 4010-9920 8 Zone Initiating Device Circuit - Class B 1 4010-9921 8 Zone Initiating Device Circuit - Class A 1 Remote Power! Notification (Select As Required) 4009-9401 40091 lrueAlert Controller 120V 1 4009-9402CA 40091 lrueAlert Controller 120V WI Low Battery Cutout 1 Canada Only 4009-9813 Transponder Interface Card 1 4100-5120 120V Domestic TrueAlert Power Supply 1 4100-5121 120V Canadian lrueAlert Power Supply 1 Canada Only Remote Annuncition (Select As Required) 4100 -9401 Remote Unit Interface Panel wIFUI - Red - Domestic & Canadian English 2 4100-9403 Remote Unit Interface Panel wIFUl - Platinum - Domestic & Canadian English 2 4100-9421 Remote Unit Interface Panel wIFUl - Red - Canadian French 2 4100-9423 Remote Unit Interface Panel wIFUI - Platinum - Canadian French 2 Canada Only 4100-9441 Remote Unit Interface Panel wIFUI - Red - International 2 4100-9443 Remote Unit Interface Panel wIFUI - Platinum - International 2 4606-9102 401OES RUI LCD Annunciator (English) 1 4606-9102BA 401OES RUI LCD Annunciator (English) 1 4606-9102CF 401OES RUI LCD Annunciator (French) 1 Canada Only 4100-7401 24 Point 10 Graphic Module (requires mounting cabinet) 1 4100-7402 64 Switch and 64 LED Driver Module with 32 on-board LED drivers (requires mounting cabinet) Ilotal Card Addresses - Not to Exceed 20 1 'Ui S4010-0004-4 412012 General Specifications AC Input Current 4 A maximum, 120 VAC @ 60 Hz nominal Including module currents and auxiliary power Output switches to Power Supply Output Total Power Supply outputs; 8 A total for "Special Application" battery backup Ratings (nominal 28 VDC Output Rating appliances; 4 A total for "Regulated 24 DC" power during mains AC on AC, 24 VDC on (see below for details) failure or brownout battery backup) conditions Auxiliary Power Tap 2 A maximum, rated 19.1 to 31.1 VDC Special Application Appliances, maximum of Simplex 4901, 4903, 4904, and 4906 Series horns, strobes, and combination horn/strobes and 70 appliances per NAC speaker/strobes (contact your Simplex product representative for compatible appliances) Regulated 24 DC Power for other UL listed appliances; use associated external synchronization modules where Appliances required UL listed for battery charging of 6.2 Ah up to 110 Ah; ULC listed for Battery capacity range charging up to 50 Ah batteries; batteries above 33 Ah require separate Battery Charger Rating cabinet (sealed lead acid batteries) Charger characteristics Temperature compensated, dual rate, recharges depleted batteries within and performance 48 hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Operating Temperature 32" to 120"F (0" to 49" C) Environmental Operating Humidity Up to 93% RH, non-condensing © 90" F (32" C) maximum Additional Technical Installation Instructions 579-989 579-969 Reference Operating Instructions Additional Data Sheet References for 40I0ES Compatible Equipment 4010ES Releasing Panels and Accessories, 4606 LCD Annunciator, Remote InfoAlarm Displays, Remote Graphic Annunciators, 110Ah Batt Chargers and Cabinets, BNIC, SafeLINC Internet Interface, SDACT, lDNet+ Communications Module, Network Interface Card (NIC), Fiber Modem Expansion Cabinets, 4009 IDNet NAC Extender, TrueAlert Addressable Controller (4009T) and 4009TPS (Remote TrueAlert Supply), Printer, PC Annunciator, IDNet Communication Sensors and Devices Subject Agent Release Applications Data Sheet S4010-0005 Subject Addr. Device Compatibility Data Sheet S4090-0011 Subject 4009 TrueAlert Controller & PS Data Sheet S4009-0003 Building Network Interface S4100-0061 Remote LCD Annunciator S4606-0002 4009 IDNet NAC Extender S4009-0002 SafeLINC Internet Interface S4100-0028 Graphic I/O Modules S4100-0005 4003EC Voice Control Panel S4003-0002 VESDA HLI S4100-0026 Remote InfoAlarm Command Center S4010-0008 Remote Battery Charger S4081-0002 SDACT S2080-0009 Network Communications S4100-0056 Remote Printer S4190-0011 Fire Alarm Network Overview S4100-0055 Multi-Signal Fiber Optics S4100-0049 PC Annunciator S4190-0013 Truelnsight Remote Service S4100-0063 S4010-0004-4 4/2012 T}( i).SIAII'l.lfX and the prmlucl ,,w,w.% lisii.'il in I/us ,,,wcriul are ,narks (Ilk/or rr/i.clL'rccI ,,,arks. (inin,11,ori:ed use i., sirieih'proliibiwd. I IfSI)A is a iradciuuark oJxiralis Pir I.ie./. V/PA 72 and Xtnionul lire A/ar,,, mud Sig,uu/inu,' Code are Irade,,,arks of 11w Valium,! lire Prowelion .4ssoe,aiwn (NIP.4)..4 S//RI/f and BAt ,wl arc IradeinlirkI of .•I./lk.41. .IiiiL'llCWI .oc,eI, ()I Healing. Refiigeialium. utnu/Ail ( ondilioning /:igilueem. B®S i rn p1 EX Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4010-0004-4 4/2012 www.simplexgrinnell.com © 2012 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:0369 Page 1 of 1 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact Pauj,,Mattern (978) 731-8542 Fax (978) 731-8881 Email: 9tfiattet©tycoint.com DESIGN: Modelf4010ES persenting the following: ModeLs4 10- 5 1, -9502, -9503, -9504, -9521, -9522, -9523, -9524, -9525, -9526, -9527, -9528 , nd -9530. Models 4010-9401, -9402,-9403,-9404,-9405,-9406,-9421, -9422, -9425, and -9426. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 120 V, 60 Hz, 4A; 220/230/240 V, 50 Hz, 2A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's Installation Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2007 Edition and meets the requirements of UL-864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Alarm verification feature shall not be implemented on initiation-device circuits that have the option of releasing an extinguishing agent or water unless these circuits release independently of the Alarm Verification feature. 08-80-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be,u'id to\verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions'and/or other Date Issued: July 01, 2013 Listing Expires ,- J ne 30, 2014 / Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division !®Simplex Rechargeable, sealed lead-acid design: Lead-calcium grid structure Immobilized electrolyte in absorbent separator High reliability dual seal construction Low maintenance, no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size For applications requiring 110 Ah batteries: Refer to data sheet S4081-0002 for 4100U systems Refer to data sheet S2081-0012 for 4100/4120 series system IIi*sttiFi1T1 Simplex K rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarni and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of systeni cabinets and the battery wiring distances are both minimized. Fire Alarm Control Panel Accessories Cabinet Mounted System Batteries; 2081 Series, Sealed Lead-Acid; 6.2 Ah to 50 Ah Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets I Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Specification Summary Nominal Voltage Rating 12 V/battery Discharge Rating 20 Hour Rate Typical Chart/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 1 60° F to 90° F (15.6°C to 32.2° C) These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. S2081-0006-16 9/2004 Inner cover Absorbent ser used to imrr ele Lead-calciur C 'Typical Construction Details Actual appearance will vary with battery size. Qaohnrl ri .tr Cell case (high impact polystyrene) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator S2081-0006-16 9/2004 Battery Specifications Battery Model Capacity @20 Hour Width* Depth* Height with Approximate Discharge Rate Terminals Weight* 2081-9272 6.2 Ah 6-1/8" (156 mm) 2-5/8" (67 mm) 4"(102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah 6" (153 mm) 4-1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) ,-2O8i?9288 -41 12.7 Ah 6" (153 mm) 4(102mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) 5" (127 mm) 7(178mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ("square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4" (171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9-1/2" (241 mm) 1 5-1/2" (140 mm) 1 8-7/8" (225 mm) 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. I Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Simplex Control Panel Model Series (see legend and notes below) _______ Model Capacity p 4006& 4009 4100U 4100&4120 4020 4003 4004 4004R 4005 4008 (all models) 4010 (2 or 3 bay) (2, 4 or 6-Unit) (2, 4 or 6-Unit) 2081-9272 6.2 Ah 1f I / I 1 1 1 1 / 2081-9274 10 Ah / / / I / / / / / I 2081-9288 12.7 Ah / / / / 2081-9275 18 Ah / Note 3 / Ext Ext Note 2 2081-9287 25 Ah Note 3 Ext / / / Ext 2081-9271 33 Ah Note 3 Ext 4 Note 3 / Ext Note 4 (rectangular) 2081-9276 33 Ah Note 3 Ext Note 3 / / Ext 2081-9296 50 Ah - - Note 3 - ZI Note 3 1 Ext Ext 1 = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 Shaded areas = Not applicable NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. S2081-0006-16 9/2004 External Battery Cabinet Compatibility Reference Externally Mounted Battery Battery Cabinets without Chargers Battery Cabinets !!! Chargers (connects to charger in panel) Model * .a Capacity 4081 2081 9301 2081-9303 Series t 2081 9270 208179281 2081-928Z. 4009-9801 4009-9802 2081-9275 18 Ah 2081-9287 25 Ah 2081-9271 (rectangular) 33 Ah 2081-9276 / I ('square") 2081-9296 50 Ah * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. /= Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specification Reference Model Description Color Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 2081-9270* External battery cabinet without charger Red 26-1/2" W x 12" H x 12" D 2081-9301 External battery cabinet with charger External battery cabinet without charger and with meters for 20819302* voltage and current (673 mm x 305 mm x 305 mm) 2081-9303' External battery cabinet with charger and with meters for voltage and current 4009-9801 For up to 18 Ah External battery cabinet without charger, 16-1/4" W x 13-1/2" H x 4-1/8" D batteries with solid door and battery harness, for close-nippled mounting to fire alarm control Beige (413 mm x 343 mm x 105 mm) For up to 33 Ah 25-3/4" W x 20-3/4" H x 4-1/8" D 4009-9802 batteries panel cabinet (654 mm x 527 mm x 105 mm) 4081 For up to 50 Ah Companion cabinet with charger for the Beige or 22-1/2" W 06-3/4" H x 8-3/8" 0 Series** batteries 4010 and 4004R fire alarm control panel Red (572 mm x 425 mm x 213 mm) * Refer to Simplex data sheet S2081-0002 for additional information. Refer to Simplex data sheet 54081-0001 for additional information. Tito. Sonji/v. am! I/IL' Simp/cr !iigo are i,atk',,zc,,kc u//rca I,,ie,,iaiio,,a/ .Sertkes .'lG or us a/li/kilt's in i/it' U.S. am/.1or ui/icr cow,iries. -MpjeX Tyco Safety Products Westminster• Westminster, MA • 0144 1-0001• USA S20981-0006-16 9/2004 www.tycosafetyproducts-usa-wm.com 2I04 lico Sa/i',r Pivthicis li'eslmi,isie, .411 rights reserved. A/I vpecf/icalions and oilier in!ormalie,, liottn were cur,t',u as o/dociiii,eni revision c/alt' aiu/ are utilymi Ia change it il/loll! 11011CC. £LSimpIEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors - Photoelectric, MEA (NYC) Acceptance* Ionization, and Heat; Standard Bases and Accessories IDi(*I TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products: 4100ES, 4100U, 4010ES, and 4010 Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% Heat sensors provide: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Ionization smoke sensors provide: Three levels of sensitivity; 0.5%, 0.9%, and 1.3% General features: UL listed to Standard 268 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMI compatibility Magnetic test feature is provided Optional accessories include remote. LED alarm indicator and output relays Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272.0026:218, 7271.0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35.93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. S4098-0019-13 10/2011 TrueAlarm Sensor Bases and Accessories 0911M. MWERIM Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test 4098-9792, Standard sensor base 4098-9789, Sensor base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (unsupervised) 4098-9791, Sensor base with supervised relay driver output (not compatible with 2120 CDT): Relay operation is programmable and can be manually operated from control panel Use with remote mount 2098-9737 relay Also includes wired connections for remote LED alarm indicator or 4098-9822 relay :ç s] 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box ALARM (shown in illustration to right) 0 S Simplex srrinti TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionization, or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. IVIOUFiLIFly rseiererlue Electrical Box Requirements: (boxes are by others) Without 4" octagonal or 4" square, 1-1/2" deep; single gang, 20 deep With i: 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference' 60 0 1-1/2"(38 mm) minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4(6.4 mm) maximum recess ------------------------------------------------- 2098-9737 Relay (mounts in 4098-9822 Relay (mounts base electrical box or remotely) in base electrical box) Relay Size: 2-1/2° X 1-1/2" X 1(3.75 cubic inches) (64 mm X 38 mm X 25.4 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. Ll 6-3/8" (162 mm) RI 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) uare flush box I' 4-7/8" (124 mm) Ml 15/16" I (24 mm) 0 lrueAlarm Bases 4098-9789,-9791, & -9792 S4098-0019-13 10/2011 TrueAlarm Sensors I1(IIt*I Sealed against rear air flow entry Interchangeable mounting EMl/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed TemperatureSetting 135"F 60ftx60ft 20ftx20ft(6.1 m) for fixed (57.2' C) (18.3 m) temperature only; RTI = Quick 50 ft x 50 ft(15.2 m)for fixed 155' F 40 ft X 40 ft temperature with either rate-of-rise (68' C) I (12-2m) I selection; RTI =Ultra Fast Smoke Sensors: Photoelectric or ionization technology sensing 3600 smoke entry for optimum response Built-in insect screens TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.10 C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° Q. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. Refer to specifIc panels/6r availability. 14 4-7/8 (124 mm) Pl LED status indicator 2-3/8' (60 mm) 4098-9733 Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 4-718' (124 mm) LED status indicator /11 2-1/8" (54 MM) 4098-9714 Photoelectric Sensor with Base TrueAlarm Ionization sensors use a single radioactive source with an outer sampling ionization chamber and an inner reference ionization chamber to provide stable operation under fluctuations in environmental conditions such as temperature and humidity. Smoke and invisible combustion gases can freely penetrate the outer chamber. With both chambers ionized by a small radioactive source [Am 241 (Americium)], a very small current flows in the circuit. The presence of particles of combustion vill cause a change in the voltage ratio between chambers. This difference is measured by the electronics in the sensor base and digitally transmitted back to the control panel for processing. Three levels of sensitivity are available for each ionization sensor: 0.5, 0.9, and 1.3% per foot of smoke obscuration. Is_4-7/8' (124 T LED status indicator 2-1/8" (54 mm) 4098-9717 Ionization Sensor with Base T1 Fr1rn11 ;lit 1iTI Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 in) may be used as a guide. For detailed application information, refer to 4098 Detectors, Sensors, and Bases Application Manual (574-709). S4098-0019-13 10/2011 TrueAlarm Sensor Bases (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description Compatibility MounhjigReqtements U4098,- —A ) Standard Sensor Base, no options Sensors 4098-9714, -9733, & -9717 I dep't; or single gang box, 4oCtoflalor4SqUareb9,X,i-i/2mlfl. min. depth Sensor Base with connections for 4098-9789 Remote LED Alarm Indicator or Unsupervised Relay Sensor Base with connections for 4098-9791 Supervised Remote Relay and connections for Remote Alarm Indicator or Unsupervised Relay TrueAlarm Sensors Model Description Photoelectric Smoke Sensor 4098-9717 Ionization Smoke Sensor 4098-9733 Heat Sensor TrueAlarm Sensor/Base Accessories Model Dscrintion Sensors 4098-9714, -9733, & -9717 2098-9808 remote LED alarm indicator or 4098-9822 relay Sensors 4098-9714, -9733, & -9717 2098-9737 remote relay (supervised) 2098-9808 remote alarm indicator or 4098-9822 relay (unsuoervised Compatibility Bases 4098-9792, 4098-9789, and 4098-9791 Comoatibilltv 4" octagonal or 4° square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. NOTE: 4098-9791 is NOT compatible with the 2120 CDT Mounting Requirements Refer to base requirements Mounting Requirements Remote Mounting requires 4" octagonal or 2098-9737 Supervised Relay, mounts remote For use with 4098-9791 base 4" square box, 1-1/2" minimum depth or in base electrical box Base Mounting requires 4" octagonal box, 2-1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator Single gang box, 1-1/2" minimum depth on single gang stainless steel plate Bases 4098-9789 and 4098-9791 Relay, tracks base LED status 4" octagonal box, 2-1/8" deep with 1-1/2" 4098-9822 (unsupervised, mounts only in base extension ring electrical box) Required for surface or semi-flush 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 mounted 4" square box and for surface mounted 4" octagonal box Specifications General Ooeratina Specifications C6ñitiOns an Sensor SupeniiPé1 PNEEH orjD auto-select, 24-40 VDC w/data, 400 tA typical, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Temperature Range 32° to 100° F (0° to 38° C) Operating with 4098-9717 or 4098 -9733 Temperature Range with 4098-9714 32" to 122" F (0° to 50° C) 15° to 122° F (-9° to 50° C) Humidity Range 10 to 95% RH Smoke Sensor 4098-9714, Photoelectric Sensor Ambient Ratings 4098-9717, Ionization Sensor Air velocity = 0-4000 ft/min (0-1220 m/min) Air velocity = 0-200 ft/mm (0-61 m/mmn); Altitude is up to 8000 ft (2.4 km) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally SuoDlied Relay Coil Voltaae 1 18-32 VDC (nominal 24 VDC) Supervisory Current 1 270 tA, from 24 VDC supply Alarm Current with 2098-9737 Relay 1 28 mA, from 24 VDC supply 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TYCO. SIMPLEX. and the product names listed in this ,n@terial are marks and or registered marks. Unauthorized use is s,ric,!r prohibited. ,v/PI 72 and National Fire Alarm and Signali,ii Code are trademarks v/the National Fire Protection Association INF!'l). iin p1 EX Tyco Fire Protection Products" Westminster, MA • 01441-0001 • USA S4098-0019-13 10/2011 © 20/! Trco Fire Protection Products. Al/rights reserved. All specifications and oilier information shoa,i it erecnnent as v/document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of I CATEGORY: 7300 — FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern©tycoint.com DESIGN: Models 4098-9789,-9789E, 9789T5P, -9789TTP, -9791,-9791E, -9791T5P, 9791TTP,-9792, -9792E, -9792T5P, 979211P, -9793,-9793E, -9793TSP, -9793TTP, -9794, -9794T5P, -9794TTP, -9795, -9795TSP, -979511P, -9796, -9796TSP, -9796TTP; *GsA4098..9792 *9793 *..9795 and *-9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Bases are intended for use with the following units: Models 4098-9714 and *GsA4098..9714 series photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:231); and Models 4098-9733 and *GSA4098-9733 heat detector (CSFM Listing No. 7270-0026:216). Models 4098-9795, -9795TSP, -9795TTP, -9796, -9796T5P, -9796TTP; *GSA4098..9795 and *..9796 are only intended for use with Models 4098-9754 or *GSA4098..9754 photoelectric smoke detector *(CSFM Listing No.7272-0026:218). Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, -9794TSP, -9794TTP, -9795, -9795T5P, -979511P; and *GSA4098-9795 employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 4098-9714, -9714T5P, -971411P, -9754 -9754TSP, -9754TTP; *GSA40989714 and -9754 analog photoelectric type smoke detectors. Units are intended for use with smoke detector bases Models 4098-9789 9789TSP, -9789TTP, -9791, -9791TSP, -9791 TIP, -9792, -9792TSP, 9792TTP, -9793, 9793TSP, -9793TTP, -9794, -9794T5P,-9794TTP; *GSA4098..9792 and *9793 (CSFM Listing No. 7300-0026:217). Models 4098-9714, -9714TSP and -971411P are listed for use with Models 4098-9750,-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755, -975515P and -9755TTP duct detector units (CSFM Listing No. 3240-0026:241). Models 4098-9754, -9754TSP -975411P; *GSA4098.9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed Models 4100, 4010, 4020, 4120 and *4008 series fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I?V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division BSim plEx UL, UL C, CSFM Listed; FM Approved; MEA (NYC) Acceptance* I1tuit*i Individually addressable manual fire alarm stations with: Power and data supplied via IDNet or MAPNET II addressable communications using a single wire pair Operation that complies with ADA requirements The NO GRIP Single Action Station and Retrofit Kit are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate Pull lever that protrudes when alarmed Break-rod supplied (use is optional) Models are available with single or double action (breakglass or push) operation UL listed to Standard 38 Compatible with the following Simplex® control panels: Model Series 4IOOES, 4100U, 4010ES, 4010,4008, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Compact construction: Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes I'i*si .rurni The Simplex addressable manual station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (lAM) constantly monitors status and communicates changes to the connected control panel via IDNet or MAPNET II communications wiring. * Refer to page 2 for specific model listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document. it is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet or MAPNET II Communicating Devices Addressable Manual Stations 4099-9020 4099-9805 4099-9001 NO GRIP NO GRIP Single action Single action Retrofit kit 4099-9002 4099-9003 With 2099-9828 Breakg!ass Push Institutional Cover kit Activation of the 4099-9001 single action manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Single Action NO GRIP Station 4099-9020. For applications such as California Building Code, Title 24, which requires "Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist" the model 4099-9020 station provides a more easily operated pull lever compared to standard stations. Retrofit of existing stations is available using the 4099-9805 Retrofit kit. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break- rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. S4099-0001-8 11/2011 Addressable Manual Station Product Selection Addressable Manual Stations. Red Housing with White Letters and White Pull Lever Model r4099900i?i Description Single action, English Housing FIRE ALARM Pull Lever PULL DOWN Ustings UL, ULC, FM, CSFM, MEA 4099-900ICB Single action, Bilingual English and French FEU FIRE TIREZ PULL ULC FM ABAISSEZ 4099-9001 CF Single action, French ALARME FEU 4099-9002 Double action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM, MEA 4099-9003 Double action, Push operation, English 4099-9020 Single action NO GRIP operation, English I FIRE ALARM PULL DOWN UL, ULC, FM, CSFM Accessories Model 2975-9178 Description Surface mount steel box, red Refer to page 3 for dimensions Cast aluminum surface mount box, red 2975-9022 2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 Surface trim plate for Wiremold box V5744-2, red 2099-9814 2099-9819 Flush mount adapter kit, black Refer to page 4 for details Flush mount adapter kit, beige 2099-9820 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 4099-9805 Retrofit Kit for field conversion of a single action station to a NO GRIP station; refer to Installation Instructions 579-1007 for details Powertind'ComunicabdPis IDNêfFMAPNET II cöiiiiiunications 1 address per station Address Means DIP switch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 3-3/4W x 1" D (127 mm x 95 mm x 25 mm) Single Gang Box Mount 4" Square Box Mount Single gang box, 2-1I2 deep 4" (102 mm) square box, 2-1/8° (54 mm) minimum (64 mm), RACO #500 or equal depth, RACO #231 or equal (supplied by others) (supplied by others) / Mount flush or with 1/16" (2 mm) -1.- .;f;;i r 0 SS maximum extension 4 Square box DO NOT RECE_ ?thrPlate1 -w _ Station II FIRE side view Single gang cover plate, 3/4" (19 mm) extension, RACO #773 PULL DOWN I or equal (supplied by others) ingie gang box outline Wail surface Semi-Flush Mount Side View 5 Simplex 2 S4099-0001-8 11/2011 Addressable Manual Stations Surface Mounting Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 2975-9178 Box 2975-9022 Cast Box 5-3/16" H x 4"W x 2-3/16" D 5" H x 3-7/8" W x 2-3/16" 0 (132 mm x 102 mm x 56 mm) (127 mm x 98 mm x 56 mm) (ordered separately) \ (ordered separately) Knockouts located top and bottom 0 FIRE 1FALAR 0 I PULL DOWN I Access for 3/4" threaded conduit located top and bottom (127 M) [Simplex] ) 1 __________________ 1"(25.4 mm) i -- 3-3/4"(95 mm) I' 4099 Series Addressable Manual Station Aim TflhI1flhI 1-1/4 (32 mm) Simplex 2975-9178 box (shown for reference) 40 2-5/8 (67 mm) 1 Switch wiring (prewired) Field wiring (shown for reference) \ = Address setting under resealable label (accessible with cover open) Station cover hinges open for installation access ; 11trur1uiii*i Refer to NFPA 72, the National Fire A larni and Signaling Code, and all applicable local codes for complete requirements for manual stations. The following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. Mounting shall be with the operable part not less than 3-1/2 ft (1.1 m) and not more than 4-1/2 ft (1.37 m) above floor level. At least one station shall be provided on each floor. Additional stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. When manual station coverage appears limited in any way, additional stations should be installed. 3 S4099-0001-8 11/2011 Addressable Manual Station, Additional Mounting Information For retrofit and new i _ I nstallations, additional Wiremold compatible mounting boxes Sc Cmv receptacle box and the required adapter plates 2099-9814 Surface trim j model V5744-2 for Wuremold box I I (supplied by are shown in the illustration to 5-1/8° H x 5" W I I others) the right. (130 min x127mm) Two gang switch box. each 3" H x 2" W x 2-3/4° D (76mrnx51 mmx70mm) add IDNet ressable station !00! %\ (supplied by others) 1 FIF-I 2099-9813 Semi-flush trim for 2 gang switch box, 6" H x 4-1/2" W (152 mm 114 mm) Flush mount adapter kit 2099-9819, Black 2099-9820, Beige \ Law 8" 3rm) Hole cutout must be a PULL minimum of 6" H by 5" W Front View Box must be recessed into wall 1" to 1-1/8.'(25.4 mm to 29 mm) 0 :0 0 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum depth (by others) Side View TYCO. SIMPLEX. and the product na,,ues listed i,, this ,na,erial are marks and'or registered marks. L'nauthori:ed use is siricthprol:ibited. AWN 72 and National Fire Alarm and Signalnig Code are trademarks oft/ic National Fire Protection Association (NFPeI). Le.va,, is a trademark oft/ic General Electric Co. JYire,nold is a trademark of the ll',re,nold C'ompanr. f3,,SjMpjIEX Tyco Fire Protection Products• Westminster, MA • 01441-0001 USA S4099-0001-8 11/2011 www.simplexgrinnell.com 201l lieu Fire Protection /iJ,./u,c,s All rights reserred. All specifications and other information s/lois: irere current as ofdoctonew revision date and are subject to change :rithou,,,o,jce. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0026:0224 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Pa attern (978) 731-8542 Fax (978) 731-8881 Email: p attrn tycoint.com DESIGN: Model 4 99-900 , -9002, -9003, -9010, -9O1OTSP, -90bhP, -9011, -9012, -9O12TSP, -9012TT , , and -9031C non-coded addressable manual pull stations. *Model 4099-9805 Conversion Kit, Models 4099-9001, -9010, and *..9020 are single action stations. Models 4099-9002 and -9011 are breakglass stations. Models 4099-9003 and -9012 include a push bar which must be punched in before being able to grab and pull down the actuating handle. Model 4099-9031C is a double action station. *Model 4099-9805 is a retrofit Kit handle for field conversion of a single action station to a NO GRIP station. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. Models are intended for use with listee's Models 4010, 4100,4100U and 4020 control units (CSFM Listing Nos. 7170-0026:226, 7165-0026:160 or 7170-0026:187, 7170-0026:250 or 7165-0026:251 and 7165-0026:178). Model 4099-9013C is intended for use with Model 4010 control unit only. For indoor use only. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *Rev. 08-03-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct IV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division fiSimplex TrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSyncTM Operation Compatible I1ui*i Visible only (V/O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Listed to UL 1971 and ULC S526 Strobes provide synchronized flash for use with: 4006, 4008, 4010, and 4100U Series fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control** 4009 IDNetTM NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang. or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex",2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* * Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Refer to page 2 for listing slates of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Wall Mount Strobes Wl!IUãE \\ FIRE fi Ceiling Mount Strobes rintm Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. t1I ('I 'i - jL9110 During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117. 1: the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). Simplex multi-candela SmartSync two-wire horn/strobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5,559492; 5,622,427; 5,865,527; 5,886.620: 6,281,789; 6,954,137: 7,005,971; and 7,006,003. S4906-0001-4 9/2009 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). SmartSync two-wire control is available from: 4006,4008,4100U, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. ritliict Scic.fk Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description O69 1011 Red White Wall Multi-candela strobe with intensity selectable as: 4906-9103 White Red 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Red White Ceiling SmartSync two-wire control compatible 4906-9104 White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" D 4905-9940 White deep surface mounted boxes (136 mmx133 mmx4l mm) Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" 0 handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-3/8" x 2-7/16" x 13/16"2) in/out 18 AWG (0.82 mm wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 5 mA for power 4905.9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8" x 1-1/4" D 4(102mm) square box (102 mm x 105 min x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white "FIRE" lettering I 5-1/8" H x 5" W x 1-1/2" D I For Wall mount strobes 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) 4905-9961" Wall mount I 6-1/16' H x 6-1/16" W x 3-1/8" D I Red wire guard with mounting plate, compatible with I semi-flush or surface mounted boxes (154 mm x 154 mm x 79 mm) 6-1/8" x 4-3/8" x 2-7/8" deep 49059926* Ceiling mount (156 mmxlii mm x 73 mm) * UL listed by Space Age Electronics Inc 2 S4906-0001-4 9/2009 Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections e Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8' H x 5" W x 2-3/4" 0 (130 mm x 127 mm x 70 mm) Wall nt Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 Cd 75 cd 110 cd 6OAT - 94 mA 186 mA 252 mA Mou Reference RMS Currents 18 VDC at other voltages 24 VDC 53 mA 84 mA 165 mA 224 mA 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4" L x 2-5/16" W x 2-5/8" D (121 mm x75 mm x 67 mm) Ceiling Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 11106d. 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 67 mA 111 mA 207 mA 281 mA 50 mA 83 mA 155 mA 211 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting çTh çjTh çTh/ 0 0 Mounting is compatible with ( ( single gang, double gang, and _________________ 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others t 0 _ 0 0 w:-t Q Wiring access hole Wiring terminals Mounting Holes. J\\4"suare(4) Single gang (2) Double gang (3) Transparent housing and lens assembly Intensity selection 110 plug, accessible only j factory from rear of housing; setting is 15 cd 15 I Removable cover Strobe intensity (tool required) viewing slot 3 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly Electrical above bottom\ boxoutline of compatible NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0001-4 9/2009 4905-9931 Adapter Plate 4905-9931 Adapter Plate nat Wire Guard - eference only, can be used on other mounting options) Ceiling Mount Strobe Installation Reference ( Single gang box (Wiremold V57445) 2-1/4" (57 mm) deep, supplied by others 141 Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) (..) C.) (..) Id' 4905-9910 Adapter Plate, required for surface mount with handy box unless la, cf j using the 4905-9926 wire guard mount strobe Optional 4905-9926 wire guard with mounting plate - - - Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens' housing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4(102mm) square box profile. 1-1/2" , (38 mm) deep Optional 4905-9961 Wire Guard Strobe ' 7 Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) 7'co is it ,'ertisa'reel trademark of Ti-co International Serrices GmbH and is used under license. Simplex, the Simplex logo. IDNe,. T,'i,cAle,t. and SmartSrnc are trademarks of 7:i'co /nte,',,atjwu,/ Ltd. and its afjiluues and are used under license. NFPA 72 and National Fire Alarm (ode are registered trademarks oft/ic National Fire l','otectio,, .tssaciatiw, (XI-TA). 13 - mplex Tyco Safety Products Westminster• Westminster, MA • 0144 1-0001 USA S4906-0001-4 9/2009 www.tycosafetyproducts-usa-wm.com 2ll119 71'coSa/eii Products JVesimi,,ster. Ailtig/its rese,,'ed. All specifications and at/Icr u,formauon s/loan Here curie, it as ofdocument ,'erisio,, <late and are subject to change i,'itl,ou, notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0316 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: SimplexlO0 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern©tycoint.com DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and -9103 are for wall mount. Models 4906-9102 and -9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VOC Candela: 15, 30, 75, and 110 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division iSimpIex lrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed* Multi-Candela, High Intensity (non-addressable) Strobe (V/O) and Horn/Strobe (NV) Ik'it*i 24 VDC high intensity notification appliance common features: Xenon strobe with intensity selectable as 135, 177, or 185 candela; visible selection jumper is secured behind strobe housing Regulated circuit design ensures consistent flash output and provides controlled inrush current Control is compatible with Simplex SmartSyncTM two-wire operation Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings available in red or white with clear lens Models are available for wall or ceiling mount Strobe operation is UL listed to Standard 1971 Appliances with audible notification (horn): Low current electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) Horn operation is UL listed to Standard 464 Strobes provide synchronized flash for use with: Simplex fire alarm control panels and NAC Extenders when selected to provide strobe synchronization or SrnartSyncTM two-wire control** Separate strobe Synchronization Modules or SmartSync Control Modules (SCMs) that convert conventional NAC inputs to a Smartsync output SmartSync two-wire operation provides: Horns controlled separately from strobes on the same two-wire circuit, activated as Temporal pattern, March Time pattern (at 60 BPM), or on continuously Wall mount appliance features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color A/V models have an available UL listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells, small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount A/V adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs ** Simplex multi-candela SmartSync two-wire hornistrobe appliance operation is protected under one or more of the following U.S. Patent Numbers: 5,559492; 5622427; 5865527; 5,886620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. Wall and Ceiling Mount High Intensity Strobes (top) and Horn/Strobes (bottom) Convenient Selection and Installation. TrueAlert multi-candela high intensity appliances provide convenient installation to standard electrical boxes. They are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall Mount. Housings are a one-piece assembly (including lens) that mounts to a single or double gang. or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling Mount. Strobe appliances install using standard single gang electrical boxes. Horn/strobe appliances install using standard 4" electrical boxes. Color choice is determined by model number. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:333 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. This product was not approved by FM or MEA (NYC) as of document revision date. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4906-0011-1 6/2009 TWA'flTUTi1I SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." SmartSync two-wire control is available from: 4006,4008,4100U, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003) Product Selection Strobe (V/O) Model Housing Lettering Mounting Description 4906-9109 Red White Wall strobe with intensity selectable as: 135, 177, or 185 candela; synchronized flash rate; SmartSync two-wire control 185 compatible 4906-9111 White Red 4906-9110 Red White Ceiling 4906-9112 White Red Horn/Strobe (NV) Model Housing Lettering Mounting Description 4906-9139 Red White Wall Horn and multi-candela strobe with intensity selectable as: 135, 177, or 185 candela; synchronized flash rate; operates with SmartSync two- 4906-9141 - White Red L4906 -9140 Red White Ceiling wire control 4906-9142 White Red Wall Mount Common Accessories Model Description Dimensions - 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep White surface mounted boxes depth w/strobe = 4-3/8" (111 mm) 4905-9940 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for retrofit, may be mounted vertical or horizontal) AN only; Optional Sound Damper; package of 20; field installed adhesive 4905-9838 backed horn output attenuator; reduces output 5 to 6 dBA NOTE: After Sound Damper installation, measure sound level to ensure compliance with applicable code requirements V/O Model AN Model Description 4905-9992 4905-9994 Red Wall Mount Replacement cover with white "FIRE" lettering 4905-9993 1 4905-9995 White Wall Mount Reolacement cover with red "FIRE" letterina 8-5/16" x 5-3/4" x 0.060' Thick (211 mm x 146 mm x 1.5 mm) 1-3/4" Diameter (44.5 mm) with 0.31" (8 mm) sound opening Dimensions 5-1/8" H x 5" W x 1-1/2" D (130 min x 127 mm x 38 mm) Synchronization Module Reference (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, requires 10 mA 1-3/8" x 2-7/16' x 13/16" 4905-9922 Class A for power; for use with V/O only when not supplied from panel (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Wire Guards and Adapters (see page 4 for reference diagrams) Model Description Dimensions 49059961* AN or V/0 Wall Mount Red Wire Guard with Mounting Plate, for semi-flush or 6-1/16" H x 6-1/16" W x 3-1/8" D surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9926 VIO Ceiling Mount Red Wire Guard with Mounting Plate, for semi-flush or 6-1/8" x 4-3/8" x 2-7/8" deep surface mounted boxes (156 min xIll mm x 73 mm) 49059927* AN Ceiling Mount Red Wire Guard for mounting to fhiti mounted electrical 8-1/2" x 6-1/8" x 3" box (216 mm x 156 mm x 76 mm) 49059928* Red Adapter Plate, required to mount 4905-9927 guard to surface mounted 9" x 7" (229 mm x 178 mm) electrical box 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to handy 4-7/8" x 3-1/8" x 0.060" D box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) 4905-9915 White I Ceiling Mount NV Surface Mount Adapter Box Extension, use to cover 1-1/2" deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) 4905-9916 Red * UL listed by Space Age Electronics Inc. 2 S4906-0011-1 6/2009 Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes. 1-1/2" (38 mm) deep, by others ref Sound sour Wiring access hole Removable cover, AN Shown for Reference viewing slot (tool is required to remove cover) Specifications (refer to Instructions 579-859 for additional information) Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 DC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAG Loading 1 Hz; with up to 35 synchronized strobes maximum per NAG Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 9311/6, non-condensing at 100° F (38° C) Screw Terminal Connections 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring AN and V/O Wall Mount Dimensions (with lens) V/O Ceiling Mount AN Ceiling Mount 5-1/8" H x 5" W 2-3/4" D(130 mm x 127 mm x 70 mm) 4-3/4° Lx 2-5/16" W 2-5/8" D (121 mm x 75 mm x 67 mm) 4-3/4 L° x 6-7/8" W x 2-5/8" 0 (121 mm x 175 mm x 67 mm) Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 '-lz rate AN Horn Ratings, UL 464 Reverberant dBA @ 10 ft (3 m); at Chamber 24 VDC (see Note 2) Anechoic Chamber Angular Dispersion Steady Sound Output Coded Sound Output (see Note 2) Wall Mount Ceiling Mount Wall Mount Ceiling Mount 86 dBA 87 dBA 82 dBA 83 dBA 92 dBA 93 dBA 92 dBA 93 dBA Per ULC S525; -3 dB at 45° off-axis for both wall and ceiling mount models Maximum RMS Current Rating per Wall Mou nt Strobe Setting (see Note 3 below) Visible Only (VIO) AudibleNisible(AN) 135 Cd 177 Cd 185 Cd 135 Cd 177 Cd 185 Cd 314 mA 390 mA 409 mA 333 mA 418 mA 433 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 279 mA 347 mA 364 mA 296 mA 372 mA 385 mA 209 mA 260 mA 273 mA 222 mA 279 mA 289 mA Maximum RMS Current Rating per Ceiling Strobe Setting (see Note 3 below) Mount Visible Only (V 0) AudibleNisible(NV) 135 Cd 177 Cd 185 Cd 135 Cd 177 Cd 185 Cd 356 mA 431 mA 447 mA 389 mA 456 mA 63A74 Reference RMS Currents 18 VDC at other voltages 24 VDC 316 mA 383 mA 397 mA 346 mA 405 mA 412 mA 237 mA 287 mA 298 mA 259 mA 304 mA 309 mA NOTES: "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal pattern or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r ....,—Electrical above bottoms ii r box outline of compatible boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor S4906-0011-1 6/2009 145 Box ite 4905-9931 Adapter Plate can be used on other mounting options) Ceiling Mount High Candela Appliances Installation Reference Ceiling reference, 4 (102 mm) square box, surface mounted box / 1-1/7'(38 mm) minimum depth Single gang box (remd V5744S) 2-1l4 (57 mm) deep, supplied by others Handy box. 1-112"(38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2 (64 mm) deep (RACO 519 or equal) supplied by others Optional 4905-99151-9916 Adapter. Ceiling reference. recommended for surface mounted box flush mounted box Optional 4905-9928 Adapter Plate, required for surface mounted electrical box Four mounting clamps included, two each side ... Also can be attached to boxes mounted to drop ceiling T-bar with 000 clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, ç) required for surface mount with handy box unless using /T ,J the 4905-9926 wire guard [ VIO Reference] Optional 4905-9927 Red Wire Guard Wiring terminals are located behind the housing'\ Ceiling mount AN Ceiling mount strobe Optional 4905-9926 wire guard with mounting plate Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 177 cd [AN Reference ] AN End View Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for re 4" (1 02 mm) square" box profile, 1-1/2 (38 mm) deep Optional 4905-9961 Wire Guard A/V -T Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) NOTE: V/O is shown for reference, AN mounts the same Tiro is a registered trademark of'/'rco lnte,nmjo,,al Seriices Ginbll and is used inider license. Simpler. the Simplex logo. IDNel. TineAle,,. and S,nar,Sr,,c (lie iradeiiiarks q/ Ti-to In,e,,,aiional Ltd. and its affiliates (111(1 (lie itsei/ ,,,,de, license. ,VFI'.l 72 and National Fi,e il/a,,,, Code are n-aeletneu-Ics oil/ic National Fire Protection elssociaiio,, (N/PA). Simplex Tyco Safety Products Westminster• Westminster, MA 01441-0001 • USA S4906-0011-1 6/2009 a www.tycosafetyproduCtS-Lisa-wm.com 02IH)9 71cu So/mi Products JVest,,,i,,sier. All ,i/,,s ,eserted. All specifications and ozlueriutfonnatio,u .cl,ouu,, ,,erec,,rrent as ofdocu,nent revision date and are subject to change without 1,011cc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 1I7 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0333 Page 1 of 2 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern©tycoint.com DESIGN: Models 4906-9109(Red Housing)/4906-91 11 (White Housing) strobe lights, 1 Hz, non-addressable, synchronizable, having selectable candela ratings of 135cd, 177cd, and 185cd. Intended for indoor use wall mounting only. Models 4906-9110(Red Housing)/4906-9112( White Housing) strobe lights 1 Hz, non-addressable, synchronizable, having selectable candela ratings of 135cd, 177cd and 185cd intended for indoor use ceiling mounting only. Models 4906-9139(Red Housing)/4906-9141 (White Housing) audible signal appliance for the hearing impaired non-addressable, synchronizable, having selectable candela ratings of 135cd, 177cd, and 185cd. Intended for indoor use wall mounting only. 4906-9140(Red Housing)/4906-9142 (White Housing) audible signal appliance for the hearing impaired non-addressable, synchronizable, having selectable candela ratings of 135cd, 177cd and 185cd intended for indoor use ceiling mounting only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 24 VDC Flash Rate: 1 Hz Candela: 4906-9109, -9110, -9111, -9112, -9139, -9140, -9141, -9142: 135cd, 177cd, 185cd, INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models 4906-9109/4906- 9111 and Models 4906-9139/4906-9141 are for wall mount only. Models 4906-9110(Red Housing)/4906-9112 and Models 4906-9139(Red Housing)/4906-9141 are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as High Candela Strobes and Horn/Strobes models 4906, -9109, -9111, -9139, -9141, -9110, -9112, -9140, -9142 suitable for the hearing impaired when used with separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. Refer to Listee's Installation Instruction Manual for details. 05-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing No. 7125-0026:0333 Page 2 of 2 05-22-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division £Simplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; lDNetTM and MAPNET Il® Communicating Devices, MEA (NYC) Acceptance* Individual Addressable Modules (lAMs) IDNet or MAPNET II addressable communications supply both data and power over a single wire pair to provide: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from lAM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex® 2081-9044 Overvoltage Protectors for outdoor wiring or electrically noisy applications For use with following Simplex control panels: Model Series 4008, 4010, and 4100U fire alarm control panels for IDNet communications Model Series 4100/4100U, 4120,4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Model 4090-9001: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Model 4090-9051: Encapsulated design for extended exposure to high humidity (LED is not present on this model) Color coded 18 AWG leads for wiring IDNet communications provides current limited monitoring: Provides monitoring of tamper switch (supervisory) and waterfiow switch (alarm) on same circuit using one point Available with IDNet communications only Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to be latched or tracked (not available with the 2120 CDT) UL listed to Standard 864 4090.900 ORDER co 1 SJUJ lJq IIIDATE COOL. 3 I DD 4090-9001 Supervised lAM (shown approximately 3/4 size) 4090-9051 Supervised lAM (shown approximately 3/4 size) Dusurintir Individual addressable modules (lAMs) receive both power and communications from a two-wire MAPNET II or IDNet circuit. They provide location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Model 4090-9001 is packaged in a thermoplastic housing and provides screw terminal connections and a status indicating LED. Model 4090-9051 is all encapsulated package with wire leads. It does not provide a status indicating LED. * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300.0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for IDNet and MAPNET II addressable communications are protected under U.S. Patent use - City of New York Department of Buildings - MEA35-93E. Additional listings may be Nos. 4796,025; 5,966,002; and 6.034,601. applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4090-0001-8 2/2006 n t r t i Contact Closure. Closure of the monitored contact(s) initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Panel Selections. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not available with the 2120 CDT). lAM Product Selection For use with IDNet communications only, these lAMs can provide quad-state sensing of normal, open circuit, short circuit, and current limited conditions. (Program type is "T-sense.") With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. Model Description Supervised lAM, mounted in thermoplastic housing with screw terminals; see applicable options below 4090-9051 Supervised lAM, encapsulated with wire leads Optional Trim Plates and Mounting Bracket for Model 4090-9001 Model Description 4090-9806 For semi-flush mounted box Trim plate with LED viewing window, requires 4090-9810 mounting bracket, 4090-9807 For surface mounted box includes mounting screws; galvanized steel 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9004 733-886 6.8 kcl, 1/2W; Standard end-of-line resistor harness for N.O. contact supervision 4081-9003 1 733-896 4.7 kO, 1/2 W 4081-9005 1 733-984 1 1.8 kQ, 1/2W Use for current limited monitoring applications Specifications Electrical dndCóthiiUnibätibns M'A.FsHflL Jëtäüt selected, 1 address per lAM Input Requirements Normally open, dry contacts Wire Connections - 4090-9001 4090-9051 Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm') Color coded wire leads, 18 AWG (0.82 mm2), 8" long (203 mm) Reference Documents Installation Instructions Field Wiring Diagrams 574-331 for 4090-9001; 579-572 for 4090-9151 842-073 for IDNet operation; 841-804 for MAPNET II operation Wiring Distances Distance from lAM to Contacts 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance Reference per channel, MAPNET II or 2500 ft (762 m) maximum from fire alarm control panel IDNet Communications 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical 4090-9001 Dimensions 4090-9051 1-9/16" W x 1-3/4" H x 1-1/4" D (40 mm x 44 mm x 32 mm) 1-9/16"W x 1-9/16" H x 9/16" D(40 mm x 40 mm x 14 mm) Housing Material, 4090-9001 Black thermoplastic Encapsulation Material, 4090-9051 Epoxy, beige Temperature Range 32° to 120° F (0° to 49 C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) 2 S4090-0001-8 2/2006 Mounting Information 4090-9001 IDNet Field wiring shown supervised lAM for reference CODE LED viewing port Fii- Single gang electrical box 2-1/2" (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate Light pipe for © LED viewing (108 mm) 1 1 14 mm) 3iSCCEC POIER I DsCOAECT FO'/ER I [eEFCRESEIciG © © 2-1/2 2-13/16" (64 mm) I (72 mm) 4090-9806, Trim plate for 4090-9807, Trim plate for 4090-9810 Mounting semi-flush mounted box surface mounted box bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED 3 S4090-0001-8 2/2006 4090-9051 Mounting Information ig electrical (64mm) depth y others) ' Single gang blank cover plate and mounting screws (supplied by others) 7ico. Simplex. the Simplex logo. MAPNETII. and lD\ei are trademarks o.ri:iii Iniernaijonal Seriices ,I(i or us a(/iliaies in the VS. and or oilier couniries. .Simplex O Tyco Safety Products Westminster• Westminster, MA •01441-0001 • USA S4090-0001-8 2/2006 www. tycosafetyproducts-usa-wm. corn 2000 'I:lco Stjfe(v Producis Westminster. All rights reserved. All specifications and other i,i/brmation shown ivere current as qfdocument revision (late and are sutjeci 10 change without notice. Simplex UL, ULC Listed; FM, CSFM, and MEA (NYC) Approved* IDNet addressable interface modules** for use with Simplex® models 4010 and 4100U fire alarm control panels 4090-9002, Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of a Form "C" contact Low power latching relay design allows IDNet communications to supply both data and module power Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4" square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 crintii IDNet Relay IAMs allow fire alarm control panels to control a remotely, located Form "C" contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. I FTtL !1T1 Model Description 4,2P:9QO2 elay IAM Optional Trim Plates Model Description 4090-9801 Trim plate with LED For semi-flush viewing window, includes i mounted box mounting screws; painted For surface 4090-9802 beige mounted box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Multi-Application Peripherals lDNetw Communicating Devices Model 4090-9002 Relay lAM 4090 Series IDNet Relay lAM Package (shown approximately 1/2 size) piifitit (Refer to Installation Instructions 574-184 for additional information.) Communications 4010 or4100U IDNet, 1 address per I device RyjAM.Poe!3 ICSupptiid tiDNétcommuniäâtiôns Relay lAM Contacts (Form "C", SPDT) 2 A @ 24 VDC, for transient Power-Limited Rating suppressed loads 1 A @24 VDC for inductive loads Nonpower-Limited Rating 1/2 A @ 120 VAC, for transient suppressed loads Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2 ) Up to 2500 ft (762 m) from fire alarm control panel Up to 10,000 ft (3048 m) total wiring IDNet Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4-1/8" H x 4-1/8' W x 1-3/8" D (105 mm x 105 mm x 35 mm) Housing Material Black thermoplastic Mounting Plate Material Sheet metal, galvanized Temperature Range 32° to 120° F (0° to 49° C), intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) IDNet addressable communications are protected by U.S. Patent No. 4,796,025. S4090-0002-5 4/02 Relay lAM Mounting Information Address setting under resealable label 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © 4-9/16' 4-5/16" (116 mm) Light pipe for LED viewing (109 mm) © © © © I 4-9/16" (116 mm) P' II 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED Si,,,p/cv. /he Simplex Ioto. and /I)A'e, are ,rwle,narks of Tern /niernaljonc,/ AG or its ci/Ii/iates in the U.S. am//or oilwr countries. fjjSirnplex TEPG-US• 91 Technology Drive" Westminster, Massachusetts• 01441-0001 USA S4090-0002-5 4/02 2002 TEPG-US (it Item, coi;q,oiiy). AII rights readied. All sj,ecj/kcilioii.c am/other information wtwif.fepg.com shown were current as o/doctmuzent revision date and c,,e subject In change without I101iCe. £®Simplex Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; lDNetTM or MAPNET Il® Communicating Devices MEA (NYC) Acceptance* 4090-9101 and 4090-9106, Zone Adapter Modules IDNet or MAPNET II communications** compatible Monitor ZAMs (Zone Adapter Modules) provide an addressable interface to a conventional initiating device circuit (lDC) Available for Class B or Class A lDCs: 4090-9101, Class B (Style B) monitoring for 2-wire or 4-wire initiating devices, with power reset connections for 4-wire devices 4090-9106, Class A (Style D) monitoring for 2-wire initiating devices Zone device power is supplied separately (typically from fire alarm control panel) Refer to device compatibility list on page 2 For use with following Simplex control panels: Model Series 4008, 4010, and 4100U fire alarm control panels for IDNet communications Model Series 4100/4100U, 4120, 4020, and 2120 Communicating Device Transponders (CDTs) equipped with MAPNET Ii communications Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4" square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 I IDNet/MAPNET II Monitor ZAMs allow a single addressable point to monitor a conventional initiating device circuit (I DC) populated with 2-wire or 4-wire initiating devices. Refer to page two for compatible devices. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300.0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. * IDNet and MAPNET It addressable communications are protected under U.S. Patent Nos. 4,796,025; 5,966,002; and 6,034,601. 0 4090 Series ZAM Package (shown approximately 1/2 size) Specifications Communications IDNet or MAPNET II, 1 address per device ZAM Input Voltage 18.9 to 32 VDC (nominal 24 VDC) 0-1 Suprrv -V. iryM6 mA maximum Aiar72mArna,dmumJ M Currei@ (actual current is determined by total device requirements) 4090-9101 ZAM, Zone Q 3.3 k, 1 W Supervision Resistor Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2 ) Up to 2500 ft ( 762 m) from fire alarm control panel Up to 10,000 ft (3048 m) total wiring IDNet or MAPNET Il Wiring distance (including 1-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4-1/8' H x 4-1/8' W x 1-3/8" D (105 mm x 105 min x 35 mm) Housing Matenal Black thermoplastic Mounting Plate Material Sheet metal, galvanized Temperature Range 32° to 120' F (0° to 490 C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) S4090-0003-2 2/2006 Product Selection ZAM Modules Model Number Description 40-91O1 Zone Adapter Module for Class B monitoring of 2-wire or 4-wire initiating devices; with power reset connections for 4-wire devices 4090-9106 1 Zone Adapter Module for Class A monitoring of 2-wire initiating devices Optional Trim Plates Model Number Description 4090-9801 For semi-flush mounted box Trim plate with LED viewing window, includes mounting screws; 4090-9802 For surface mounted box galvanized steel End-of-Line Resistor Harness Model Number Reference No. Description 4081-9002 733-893 3.3 W, 1 End-of-Line Resistor Harness for 4090-9101 Class B zone monitoring r1t,p,.1'. Description Model Number Compatible Maximum Bases Quantity Direct connect photoelectric smoke detector 2098-9209 No base 4098-9401 4098-9402 required 20 4098-9403 4098-9404 Electronic heat detectors 4098-9612 4098-9788 4098-9613 20 4098-9614 4098-9684 4098-9683 1 4098-9615 4098-9601 4098-9788 20 Photoelectric smoke detectors 4098-9602 4098-9683 1 4098-9605 4098-9788 20 Ionization smoke detector 4098-9603 4098-9683 1 Duct detector housing with 4098-9601 detector 4098-9685 N.A. 20 Reference for Existing Equipment 2098-9201 2098-9211 20 2098-9202 Smoke detectors 2098-9203 2098-9576 2098-9637 1 4098-9407 Electronic heat detectors 4098-9408 4098-9409 2098-9211 20 4098-9410 NOTES: Four-wire detector operation is compatible with conventional listed contact closure initiating devices. Four-wire detectors require detector voltage to be connected to resettable power terminals. Refer to installation instructions 574-183, and field wiring diagram 842-073 for additional information. Contact your local Simplex product supplier for additional compatible devices. 2 S4090-0003-2 2/2006 ZAM Mounting Information Address setting under " resealable label - - 4" (102 mm) square box, 2-1/8° (54 mm) minimum depth, RACO 232 or equal (supplied by others) 4090-9101/9106 ZAM Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © m) Light pipe for LED viewing (116 m 4-9/16" (116 mm) ii 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED 3 S4090-0003-2 2/2006 '\'co. Simpler. i/u. Simpler logo. ADIAVETH. and IDNel are i,ode,,ic,,kc /lie.o l,,ier,,uiio,u,l Services AG or ill tiffiliules in ilw U.S. ciiul/or oilier countries. - mplex Tyco Safety Products Westminster• Westminster, MA • 0144 1-0001 USA S4090-0003-2 2/2006 www.tycosafetyproducts-usa-wm.com © 20110 Trw Sa/i,ir I',vdiwis Wesi,niwiie,: All rig/u.s iere,ed 411sj,eci/iraiionc am/other in/ornuiliwi chum; wen, carrel,/ as o/doc,,,,,eai revision dale cinclairsabjeci to change iiithoat ,wiice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300— FIRE ALARM CONTROL UNITACCESSORIESIMISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models* 4090-9001, -9001TSP, -900111P, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106T5P, and-910611P Class "A" ZAM Initiating Module; 4090-9101, -9101TSP, and -910111P Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: "Recert. 03-29-2006 jw r, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 . Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division £Simplex UL Listed; FM and CSFM Approved* I71uii* MAPNET II ZAMs provide an addressable interface to conventional fire alarm zone circuit devices** including: Initiating devices (Monitor ZAM) Notification appliance circuits (Signal ZAM) Control relays (Control ZAM) These ZAMs are compatible with the following Simplex® fire alarm control panels when equipped with MAPNET II communications: 4100/4100U Series fire alarm control panels 4100 Series Universal Transponders 4120 Series Network node fire alarm control panels 4020 Series fire alarm control panels 2120 Communicating Device Transponders MAPNET II communications can be wired: NFPA Style 4/Class B or Style 6/Class A Style 4/Class B communications may be wired either "T" tapped or In/Out Convenient DIP switch address selection UL listed to Standard 864 lIi*iF1ti1 MAPNET II zone adapter modules (ZAMs) provide an addressable interface between conventional zone devices and the host fire alarm control panel. Monitor ZAMs provide status monitoring and supervision ofan initiating device circuit (IDC) zone and are used for circuits with non-addressable detectors and for other contact closures such as watertlow and tamper switches or non-addressable manual stations. Diflerent models of Monitor ZAMs are available for two-wire IDCs Class B. or Class A, and for four-wire IDCs with Class B IDC input. Each type required a separate 24 VDC input power from a listed fire alarm power supply. Signal ZAMs supervise and operate 24 VDC notification appliances, speakers, and telephone circuits. Output capacity is up to 2 A @ 24 VDC, or 50 W of 25 VRMS speakers, or up to three simultaneously activated firefighter phones. The signal ZAM is available for either Style Y/Class B or Style Z/Class A operation for notification appliance circuits. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:182 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. This product was not tIC listed or approved by MEA (NYC) as of document revision date. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. MAPNET Il® Communicating Devices Zone Adapter Modules (ZAMs) Addressable Interface to Conventional Circuits Signal/Control ZAM C N L i Monitor ZAM Control ZAMs provide addressable control functions such as elevator capture, HVAC control, pressurization fan control, and damper control. The control relay provides a DPDT contact (contact ratings are shown on page 4). General _Specifications Communications Supplied by MAPNET II, 24 to 40 VDC with data Power Separate 24 VDC required from listed fire alarm power supply Wiring Information Refer to reference diagrams on pages 3 and 4 Wire Connections Screw terminals for in/out wiring, 181012 AWG wire Address Means DIP switch, 8 position Temperature Range 32° F to 120° F (0° C to 490 C) intended for indoor operation Humidity Range Up to 85% RH at 86° F (30° C) MAPNET II addressable communications are protected by U.S. Patent No. 4,796,025. S2190-0012-14 12/01 Product Selection Zone Adapter Modules, Monitor ZAMs (separate 24 VDC power is required) Model Cover Type Description SupervTsory Cu rent Alarm Current 2190-9153 Surface Monitor ZAM, Class A (Style 0) 2190-9154 Flush 2190-9155 Surface Monitor ZAM, Class B (Style B) 20 mA @24 VDC 90 mA @ 24 VDC 2190-9156 Flush 2190-9157 Surface I 4-Wire Detector ZAM, Class B lDC input I 2190-9158 Flush Zone Adapter Modules, Signal and Control ZAMs (separate 24 VDC power is required) Model Description SUpervisory Current Alarm Current 2190-9159 Surface Signal ZAM, Class A (Style Z) Flush 15 mA @24 VDC 65 mA @ 24 VDC 2190-9160 2190-9161 . . .Cover Type .... Surface Signal ZAM, Class B (Style Y) 15 mA @24 VDC 40 mA @ 24 VDC 2190-9162 Flush 2190-9163 Surface Control Relay ZAM, DPDT Contacts 10 mA @ 24 VDC 2190-9164 Flush Typical ZAM Mounting 4-11/16" (119 mm) Square box, 2-1/8" (54 mm) deep / çTh çTh /Th(Th/ Typical ZAM assembly ( o ( 'y (5 r r ____ 4-11/16" (119 mm) Square extension ring, 1-1/2" (54 mm) deep _ I Flush cover, 5-7/16" l IDSimP ° 1) square (138 mm) Surface cover, 4-15/16" square (125 mm) 2 S2190-0012-14 12/01 4- Wire detector ZAM wiring 2-Wire monitor circuit + Class B, Style B 2-Wire monitor circuit 'T'Tapped + or IN/OUT wiring - Monitor circuit Resettable Detector power End of line o relay Monitor ZAM Reference Wiring Diagram Signal ZAM Wiring Reference + + Tapped or lN/OUlwinng - Class B/Style V notification appliance circuit (speakers shown for reference) r phone Class A/Style Z notification appliance circuit 3r phone 3 S2190-0012-14 12/01 Control ZAM Reference Wiring Diagram Control ZAM + - 0 0— - N. C. 1 24 VDC - Common 1 A 0— —NO.1 ~ "T" Tapped or MAPNET II IN/OUT wiring communications _______________ - Shield ~Cmmo'n'2 0— —NC Controlled device Control Power Control ZAM Relay Ratings (DPDT Contacts) Application Resistive Rating Inductive Rating** Power Limited* 2 A @ 28 VDC 1 A @ 28 VDC 2A@28VDC 1A@28VDC Non-Power Limited 1/2 A @ 120 VAC 1/2 A @ 120 VAC * DC Voltage must be from a listed Fire Alarm power supply ** Inductive loads must be properly suppressed. Tico..i,I,p/e.v. the Simpler Inca. nail .I.II'XI:7 I/arc iradeiiiarks iifiicii l,,i,.,•,,aiin,ia/ .Scr,ices A(; allis a//iliaicx in i/ic 1.S. aizil in al/ic, caunir,cx. SirnpIex Westminster, Massachusetts 01441-0001 USA wwwsimplexnet.com S2190-0012-14 12/01 r 200/ Si,,,ple.v /in,L' Recorder Co. 1)/IA 7K1'(;(iX (a 7'i,co cmnpanu).A/I mlgl,is reserved. .1/I .cped/kau,n,s and ni/Icr i,ifiir,?iathni s/loll,, ,rcre carmen, as a/d,icu,,ic,n rerisin,, i/ale and arc cu/i/eel in el,a),ge iu/Inul nniicc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0182 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNlTACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 2190-9146, -9147, -9159, *9160 Class A Signal ZAMs; 2190-9140, -9141, *..9161 *..9162 Class B Signal ZAMs; 2190-9138, -9139, *9157 *9158 4-Wire Detector ZAMs; 2190-9144, -9145, *9153 *..9154 Class A Monitor ZAMs; 2190-9136, -9137, *..9155 *9156 Class B Monitor ZAMs; 2190-9142, -9143, *9163 *..9164 Control ZAMs; Models *4190..9050 *9051 4.20mA *monitor ZAMs; Models *21909169 and *21909170 line-powered MAPNET isolators. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as line-powered devices for use with MAPNET circuits of the following control units: Model 4100 series (CSFM Listing No. 7165-0026.160), Model 2120-8018 (CSFM Listing No. 7165-0026.126) or Model 4020-8001 (CSFM Listing No. 7165-0026.178). All devices are intended for indoor use only. *Rece 10-17-2006 jw To This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct eRV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division SimplexGrinnell LP S:mplexGrinnell BE SAFE. 3568 Ruffin Road, South San Diego, CA 92123-2597 A Tyco International Company Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com License Number 968851 SIMPLEXGRINNELL LP Business 12728 SHOEMAKER AVENUE Information SANTA FE SPRINGS, CA 90670 Business Phone Number: 714) 870-1010 Ent!ty: ........P.. ........ ... ..... ............. . ....... . Issue Date 12/29/2011 Expire Date 12/31/2013 License Status This license is current and active. All information below should be reviewed. Additional Status: Classifications: CIO ELECTRICAL C16 FIRE PROTECTION CONTRACTOR This license filed Contractor's Bond number 82293120 in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/12/2011 This license filed Bond of Qualifying Individual number 82293121 for MAYLE RONALD GILBERT in the amount of $12,500 with the bonding company FEDERAL INSURANCE Bonding: COMPANY. Effective Date: 12/12/2011 BQI's Bonding History This license filed Bond of Qualifying Individual number 82293122 for ROSTEN TIMOTHY PAUL in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/12/2011 OQIs Bonding History This license has workers compensation insurance with the NATIONAL UNION FIRE INSURANCE COMPANY OF PITTSBURGH _PA Workers' Compensation: Policy Number: WC043464662 Effective Date: 09/28/2012 Expire Date: 10/01/2013 Personnel listed on this license (current or disassociated) are listed on other licenses. 1/3/2013 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XXXXXXXXX SimplexGrinnell BE SAFE. A Tyco International Company SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST 1/3/2013 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XXXXXXXXX