HomeMy WebLinkAbout1945 DOVE LN; ; AS03022010/8/2020 AS030220 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS030220
Job Address: 1945 DOVE LN Status: ISSUED
Permit Type: -SPRINK Applied 10/28/2003
Parcel No: 2150521500 . Approved: 1/14/2004
Lot#: 0
Reference No.: Issued: 1/14/2004
PC #: . Inspector:
Project Title: LA COSTA GREENS BLDG. 3 THREE FIRE INSPECTIONS
Applicant: Owner:
REAL ESTATE COLLATERAL MANAGEMENT
CO
C/O LIZ LAYMAN! MORROW DEV
1903 WRIGHT PL #180
CARLSBAD CA
Fees ($) Add'l Fees ($) Total ($) Balance ($)
165 0 165
. 0.
(.
- dq•
' LIFEGUARD FIRE PROTECTION,JC.
2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, c/J056
(760) 806-9997 • FAX (760) 806-4813
Hydraulic Design Information Sheet .
Name: La Costa Greens Date: 03/24/04 .
LocationT 1945 Dove LaneL.
Building: New System No. Carport
Contractor: Lifeguard Fire Protection, Inc. Contract No.
Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP4
Construction: Z Combustible 0 Non-Combustible Ceiling Height 8'-0" Ft.
SYSTEM DESKIN
Z NFPA 13: 0 Light Hazard Ordinary Hazard Group C
O NFPA 231 0 NFPA 23 10 Figure: o Other (Specify) Area reduced per NFPA 13 Section 7-2.3.2.4
DSpecific Ruling ____ Made By
1 II 2 II 3 U Extra Hazard
Curve:
Date
Area of Sprinkler Operation 900 sq ft System Type
Density .15 Jg Wet 0 Dry 0 Deluge 0 Pre-Action
Area Per Sprinkler 125 sq ft Sprinkler or Nozzle
Hose Allowance GPM: Inside 0 Make Tyco Model LFII
Hose Allowance GPM: Outside 250 Size 1/2" K-Factor: 4.9
Rack Sprinkler Allowance n/a Temperature Rating 155
CALCULATION SUMMARY
GPM Required 156.21 PSI Required 65.83 At City Connection
"C" Factor Used: . Overhead 120 Underground 150
WATER SUPPLY
Water Flow Test Pump Data Tank or Reservoir
Date & Time . 10/17/03 10:45am. Rated Capacity n/a Capacity n/a
Static PSI 72 At PSI n/a Elevation n/a
Residual PSI 64 Elevation n/a
GPM Flowing 1480 Well
Elevation 190' Proof Flow n/a GPM
Location Point of connection at existing main in Dove Lane
Source of Information Carlsbad Fire Department
COMMODITY STORAGE
Commodity ... Class Location
- Storage Height Area Aisle Width
Storage Method: Solid Piled % Palletized % Rack
-
Rack
O Single Row 0 Conventional Pallet
O Double Row 0 Slave Pallet
0 Multiple Row 0 Open
Flue Spacing In Inches
Longitudinal
______ Transverse
- Horizontal Barriers Provided
O Automatic Storage 0 Encapsulated O Solid Shelving El Non-Encapsulated
Clearance From Top of Storage to Ceiling
Ft. . In.
1
d
La Costa Greens Bldg #3 carport .15/900 Sigma Dynamics Corporation 7700 Supply! Demand Graph
iiiu•Margin
Pressure
-. ui• 9.57 PSI _________
I:!
• - :: .u•i••
I, • II_._ iui••
: .1 - -- --
---- -
--____
iii.u•
iimu•
iiuu -- iuu•• 1 11 7
Water Flow (GPM)
System Demand..
Sprinkler Demand 54.31 PSI 1 156.21 GPM
Additional Flows 250.00 GPM
Hose at Source 0.00 GPM
Total Demand 54.57 PSI 0 406.21 GPM
Water Supply..
Static 64.80 PSI
Residual 57.60 PSI 5 1480.00 GPM
Elevation 0.00 PSI
03-09-2002 PAGE 1 SUBMITTAL SERIAL NO:2932HY4
La Costa Greens
Building #3 Carport .15/900
FLOW TEST RESULTS
Water Supply
STATIC 64.80 PSI
RESIDUAL 57.60 PSI @ 1480.00 GPM
CITY PRESSURE AVAILABLE AT 406.2 GPM
SUMMARY OF SPRINKLER OUTFLOWS
ACTUAL MINIMUM
SPR FLOW FLOW K-FACTOR PRESSURE
101 20.59 18.75 5.60 13.52
102 19.96 18.75 5.60 12.70
103 19.65 18.75. 5.60 12.32
104 19.57 18.75 5.60 12.21
105 19.74 18.75 5.60 12.42
106 19.12 18.75 5.60 11.66
107 18.83 18.75 5.60 11.31
108 18.75 18.75 5.60 11.21
64.14 PSI
TOTAL WATER REQUIRED FOR SYSTEM
OUTFLOWS AT 7
TOTAL WATER REQUIREMENT
PRESSURE REQUIRED AT 0
MAXIMUM PRESSURE UNBALANCE IN LOOPS
MAXIMUM VELOCITY FROM 20 TO 101
156.21 GPM
250.00 GPM
406.21 GPM
54.57 PSI
0.00 PSI
14.12 FPS
I •1
SUBMITTAL SERIAL NO:2932HY4 03"09-2002--PAGE 2
La Costa Greens
Building #3 Carport .15/900
Location Flow Pipe Fittings Equiv Friction Pressure • in Size & Length Loss Summary
From To GPM IN Devices Ft PSI/Ft PSI
104 10.8 . 1.080 .L 10.00 C=120 PT 11.21 (108)
Q 18.75 F=0 F 0.00 PE 0.00
BN T 10.00 0.1002 PF 1.00
23 104DQ 19.57 1.080 L . 5.25 C=120 PT 12.21 (104)
Q 38.32 F=T,E F 8.10, PE 0.32
• BN T 13.35 0.3760 PF 5.02
PT 17.55 ( 23)
103 107 1.080 L 10.00 C=120 PT 11.31 (107)
Q 18.83 F=0 F 0.00 PE 0.00
BN T 10.00 0.1010 PF 1.01
22 103bQ. 19.65 1.080 . L 5.25 C=120 PT 12.32 (103)
Q 38.49 F=T,E F 8.10 PE 0.32
BN T 13.35 0.3790 PF 5.06
PT 17.70 ( 22)
102
------------------
106 1.080 L 10.00 C=120 PT 11.66 (106)
Q 19.12 F=0 F 0.00 PE 0.00
BN • T 10.00 0.1039 PF 1.04
21 102DQ 19.96 1.080 L 5.25 C=120 PT 12.70 (102)
Q 39.08 F=T,E F 8.10 PE 0.32
.
• BN T 13.35 0.3900 PF 5.21
PT 18.23 ( 21)
101 105 • 1.080 L 10.00 C=120 PT 12.42 (105)
Q 19.74 F=0 F 0.00 PE 0.00
BN
•
T 10.00 0.1102 PF 1.10
20 101DQ 20.59 1.080 L 5.25 C=120 • PT 13.52 (101)
Q 40.33 F=T,E F 8.10 PE 0.32
BN . T 13.35 0.4133 PF 5.52
------------ PT 19.36 ( 20)
8 7 7.758 L 220.00 C=150 PT 54.26 ( 7)
Q 281.37 F=GV F 6.04 PE 0.00
LU T 226.04 0.0007 PF 0.16
3 8 • 7.758 L 158.00 C=150 PT 54.42 ( 8)
Q 281.37 . F=GV,EE/GV,T F 78.57 PE 0.00
LU T 236.57 0.0007 PF 0.17
1 3 . • 7.758 . L 1.00 C=150 . PT 54.59 ( 3)
Q 281.37 F=0 F 0.00 PE 0.00
LU . T 1.00 0.0007 PF 0.00
PT 54.59 ( 1)
SUBMITTAL SERIAL NO:2932HY4
La Costa Greens
Building #3 Carport .15/900
Location Flow Pipe Fittings
in Size &
From To GPM IN Devices
03-09-2002 PAGE 3
Equiv Friction Pressure
Length Loss Summary
Ft PSI/Ft PSI
6 7 7.758 L 623.00 C=150 PT 54.26 ( 7)
Q 124.84 F=EE,GV/EE,GV,2EE F 66.44 PB 0.00
LU T 689.44 0.0001 PF 0.07
5 6 7.758 L 415.00 C=150 PT 54.33 ( 6)
• Q 124.84 F=GV,2EE/2EE F 60.40 PE 0.00
LU T 475.40 0.0001. .PF . 0.05
4 5 7.758 . L 174.00 C=150 PT 54.38( .5)
• Q 124.84 F=0 F 0.00 PE 0.00.
LU T 174.00 0.0001 PF 0.02
2 4 7.758 L 596.00 C=150 PT 54.40 ( 4)
Q 124.84 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00
LU. T 742.52 0.0001 PF 0.07
1 2 • 7.758 L 1.00 C=].50 PT 54.47 ( 2)
Q 124.84 F=0 F 0.00 PE 0.00
LU T 1.00 0.0001 PF 0.00
PT 54.47 ( 1)
22 23
------------------
2.203 L 12.50 C120 PT 17.56 ( 23)
Q 38.32 F=0 F 0.00 . PH 0.00
FM • T 12.50 0.0117 PF 0.15
21 22DQ 38.49 2.203 L 12.50 C=120 PT 17.71 ( 22)
Q 76.81 . F=0 F 0.00 . PE 0.00
FM T 12.50 0.0423 PF 0.53
20 21DQ 39.08 2.203 • L 12.50 C=120 PT 18.24 ( 21)
Q 115.89 F=0 F 0.00 PE 0.00
FM T 12.50 0.0905 PF, 1.13
18 20DQ 40.33 2.203 L 90.00 C=120 PT 19.37 ( 20)
Q 156.21 F=T.,8E/T F 61.60 'E -0.87
FM T 151.60 0.1572 PF : 23.83.
17 18 . 2.203 . L 63.00 C=120 PT 42.33 ( 18)
Q 156.21 F=T/T F 23.20 PE 0.00 FM T 86.20 0.1572 -PF 13.55
16 17 .3.314 L 20.00 C=120 PT • 55.88 C 17)
Q 156.21 . F=8E F 58.40 PE 0.87, FM T 78.40 0.0215 PF 1.69
- .1
SUBMITTAL SERIAL NO:2932HY4 03-09-20'02-PAGE 4
. La Costa Greens
Building #3 Carport .15/00
Location Flow Pipe Fittings Equiy Friction Pressure
• . in in Size & Length Loss Summary From To. . IN Devices Ft- PSI/Ft PSI
15 16 3.314 L 116.00 C=120 . PT 58.44 ( 16)
Q. 156.21 • F=2E/T F 33.50 PE 0.00
FM T 149.50 0.0215 PF 3.21
11 15 • • 3314 . L . 7.58 C=120 PT 61.65 ( 15)
. Q 156.21 F=cV,E F 28.85 PE 3.28
FR T 36.43 0.0215 PF. 0.78.
10 11 . 4.280 • L 7.00 C=140 PT 65.71 ( 11)
Q .156.21 F=E F 17.92 PE . 0.00
UN •• T 24.92 0.0047 PF 0.12
9 10 4.266 •
• L 37.00 C=150 PT 65.83 ( 10)
Q. 156.21 • F=T F 38.42 PE 0.00
UN
•
T. 75.42 0.0042 PF 0.32
4.266 L 71.00 C=150 PT 66.15 ( 9)
Q 156.21 F=T,GV,DDC/3E F 99.89 PE -27.30
UN T 170.89 0.0042 PF 0.72
4" Watts 909 RPDA 14.69
------------- PT 39.57 ( 7)
0 .1 7.758 L 1.00 C=150 PT 54.57 ( 1)
Q 406.21 .F=0 F 0.00 • PE 0.00 UN T 1.00 0.0013 PF 0.00
-. . . • PT 54.57 ( 0)
LIFEGUARD FIRE PROTECTION, INC.
2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056
(760) 806-9997 • FAX (760) 806-4813
Hydraulic Design Information Sheet
Name: La Costa Greens Date: 03/24/04
Location: 1945 Dove Lane
Building: New System No. 2-head
Contractor: Lifeguard Fire Protection, Inc. Contract No. ________ Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP4
Construction: Z Combustible D Non-Combustible Ceiling Height 81-0" Ft.
NFPA13:
U NFPA231
0 Other (Specify)
Specific Ruling
U Light Ha
0 NFPA231C:
Residential
SYSIbM UIS1UN
Ordinary Hazard Group 1 112113 U Extra Hazard
Figure: Curve:
Made By Date
Area of Sprinkler Operation 2-head System Type
Density .10 Z Wet 0 Dry 0 Deluge 0 Pre-Action
Area Per Sprinkler 20' x 20' Sprinkler or Nozzle
Hose Allowance GPM: Inside 0 Make Tyco Model LFII
Hose Allowance GPM: Outside Size .1/2" K-Factor. 4.9
Rack Sprinider Allowance n/a Temperature Rating 155
CALCULATION SUMMARY
GPM Required 40.21 PSI Required 56.22 At City Connection "C" Factor Used: Overhead 120 Underground 150
L'IIJ WI
Water Flow Test Pump Data Tank or Reservoir Date &, Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a
GPM Flowing 1480 well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane
Source of Information Carlsbad Fire Department
COMMODITY STORAGE
Commodity
Storage Height
Storage Method: Solid Piled
Rack
O Single Row 0 Conventional Pallet F_1 Double Row 0 Slave Pallet
0 Multiple Row 0 Open
Flue Spacing In Inches
Longitudinal Transverse
Horizontal Barriers Provided
Class Location
- Area Aisle Width
% Palletized % Rack
O Automatic Storage 0 Encapsulated O Solid Shelving 0 Non-Encapsulated
Clearance From Top of Storage to Ceiling
Ft. In.
La Costa Greens Bldg #3 2-head cab Sigma Dynamics Corporation 7700 8ueelu,I Demand GraDh
-. Margin
Pressure 21.73 PSI—
Flow 2647.72_?N
--
- -
---- - -- iiuiu -- ----€-- -
q1m U11N
15 RON
IsII 1000 12DO 1400 •ii
Water Flow (GPM) System Demand..
Sprinkler Demand
Additional Flows
Hole at Source
Total Demand
43.06 PSI
43.06 PSI
S 40.21 GPM
0.00 GPM
0.00 GPM
5 40.21 GPM
Water Supply..
Static, 64.80 PSI
Residual 57.60 PSI
Elevation 0.00 PSI
5 1480.00 GPM
03-09-2002 PAGE 1 SUBMITTAL SERIAL NO:2932HY4
La Costa Greens
Building #3 third floor 2-head calculation
20' x 20' spacing
FLOW TEST RESULTS
Water Supply
STATIC 64.80 PSI
RESIDUAL. 57.60 PSI @ 1480.00 GPM
CITY PRESSURE AVAILABLE AT 40.2 GPM
SUMMARY OF SPRINKLER OUTFLOWS
ACTUAL MINIMUM
SPR FLOW FLOW K-FACTOR PRESSURE
162 20.00 20.00 4.90 16.66
163 20.21 20.00 4.90 17.02
64.79 PSI
TOTAL WATER REQUIRED FOR SYSTEM 40.21 GPM
TOTAL WATER REQUIREMENT . . 40.21 GPM
PRESSIJRE.REQUIRED AT 0 43.06 PSI
MAXIMUM PRESSURE UNBALANCE IN LOOPS 0-00 PSI
MAXIMUM VELOCITY FROM 150 TO 151 13.55 FPS
20' x 20' spacing
Location Flow Pipe Fittings Equiv Friction Pressure
in Size & Length Loss Summary.
From To GPM IN Devices Ft PSI/Ft PSI
161 162 1.101 L 13.00 C=150 *PT 16.66 (162)
Q 20:00 F=DPV,E F 6.00 PE 0.00
AO T 19.00 0.0680 PF 1.29
PT 17.95 (161) ------------------
161 163 1.101 L 7.50 C=150 PT 17.02 (163)
Q 20.21 F=DPV,E F 6.00 PE 0.00
AO T 13.50 0.0694 PF 0.94
160 161DQ 20.00 1.101 L 2.00 C=150 PT 17.96 (161)
Q 40.21 F=E F 5.00 PE 0.22
BN1 T . 7.00 0.2477 PF 1.73
153 160 1.101 L 32.00 C=150 PT 19.91 (160)
. • Q 40.21 F=E,DPV,2E/DPV,E F 22.00 PE 0.00
BN1 T 54.00 0.2477 PF 13.38
PT 33.29 (153) ----------------
150 151 1.101 • L 1.75 C=150 PT 46.72 (151)
Q 40.21 • F=T/E F 10.00 PE 0.32
•• BN • • T 11.75 0.2477 PF 2.91
PT 49.95 (150) ------------------
8 7 7.758 L 220.00 C=150 PT 43.06 ( 7)
Q 28.25 F=GV. F 6.04 • PE 0.00
LU T 226.04 0.0000 PF 0.00
3 . 8 7.758 . L 158.00 C=150 PT 43.06 ( 8)
Q 28.25 F=GV,EE/GV,T F 78.57 PE 0.00
LU P 236.57 0.0000 PF 0.00
1 3 • 7.758 • • L 1.00 C=150 PT 43.06 ( 3)
Q 28.25 F=0 F 0.00 PE 0.00
LU T 1.00 0.0000 PF 0.00
PT 43!06 ( 1) -----------------
6 7 7.758 • L 623.00 C=150 PT 43.06 ( 7)
Q 11.97 F=EE,GV/BE,GV,2EE F 66.44 PE . 0.00
LU P 689.44 0.0000 PF 0.00
5 6 • 7.758 • L 415.00 C=150 PT 43.06 ( 6) Q 11.97 F=GV,2EE/2EE F 60.40 • PE 0.00
• LU T 475.40 0.0000 PF 0.00
4 5 . 7.758 L 174.00 C=150 PT 43.06 ( 5)
. Q 11.97 F=0 F 0.00 PE 0.00
LU T 174.00 00000 PF 0.00
SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 3
La Costa Greens
Building #3 third floor 2-head calculation
20' x 20' spacing
Location Flow Pipe Fittings Equiv Friction Pressure
in Size & Length Loss Summary
From To . GPM IN Devices Ft PSI/Ft PSI
2. 4 7.758 L 596.00 C=150 PT 43.06 ( 4)
Q 11.97 F=T,GV,4EE/GV2EE F 146:52 PE 0.00
LU T 742.52 0.0000 PF 0.00
1 2 7.758 L 1.00 C=150 PT 43.06 ( 2)
Q 11.97 F=0 F 0.00 .PE 0.00
LU T 1.00 0.0000.PF .0.00
------------------ PT 43.06 C 1)
152 153 1.101 L 10.00 C=150 PT 33.28 (153)
Q 40.21 F=DPV F 1.00 PE 4.33
FRi T 11.00 0.2477 PF 2.72
151 152 1.101 L 9.00 C=150 PT 4033 (152)
Q 40.21 F=DPV F 1.00 PE 3.90
FRi T 10.00 0.2477 PF 2.48
---------------- PT .46.71 (151)
18 150 2.203 • L 63.00 C=120 PT 49.95 (150)
Q 40.21 F=T,8E F 50.00 PE -0.87
FM T 113.00 0.0128 PF 1.45
17 18 2.203 L 63.00 C=120 PT 50.53 C 18)
Q 40.21 F=T/T F . 23.20 PE 0.00
FM T 86.20 0.0128 PF 1.10
16 17 3.314 L 20.00 C=120 PT 51.63 .( 17.)
Q 40.21 F=8E F 58.40 PE 0.87
FM T 78.40 0.0017 PF 0.13
15 16 • 3.314 L 116.00 C=120 PT 52.63 ( 16)
Q 40.21 F=2E/T F 33.50 PE 0.00 FM T 149.50 0.0017 PF 0.25
ii 15 3.314 L 7.58 C=120 PT 52.88 C 15) Q 40.21 . F=V,E F 28.85 • PE 3.28
FR T 36.43 0.0017 PF . 0.06
10 11 . 4.280 . L 7.00 C=140 PT 56.22 ( 11)
Q 40.21 F=E F 17.92 -PE 0.00 • UN T 24.92 0.0004 PF 0.01
9 10 4.266 L 37.00 C=150 PT 56.23 C 10) Q 40.21 F=T F 38.42 PE 0.00 UN T 75.42, 0.0003 PF 0.02
SUBMITTAL SERIAL NO:2932HY4 . . . 03-09-2002-PAGE 4
La Costa .Greens . .
Building #3 third floor 2-head calculation
20' x. 20' spacing .
Location Flow Pipe Fittings Equiv Friction Pressure
in Size & Length Loss Summary
From To GPM IN
•
Devices Ft PSI/Ft PSI
7 9 . 4.266 L 71.00 C=150 PT. 56.25 ( 9)
Q 40.21 F=T,GV,DDC/3E F 99.89 PE -27.30
UN T i70.89 0.00:03 PF 0.05
4" Watts 909 RPDA 14 .. 02
PT 29.00 ( 7) ------------------
0 1 7.758 . L. 1..,0:0C=15.0 PT 43.06 1)
Q . 40.21 F=0 F 0.00 PE 0.00
UN T 1.00 0.0000 PF 0.00
PT 43.06( 0)
LL = = = =
I1
IIIIit r 3
IIçf II
—SCK/BCK \
CH UNV
IT TO s-rRucTuRE GOts x 2" RED COUPUNG
- - - Ei = -9 - = = --Ii -
1' SUPPLY TO 2ND FLOOR I I
TYPICAL AT EACH urr I ii
•
• /
LP CôirP ruL1
Lb •4
BDRM 4
=
ENTI
C-
LIFEGUARD FIRE PROTECTION, INC.
2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056.
(760) 806-9997 • FAX (760) 806-4813
Hydraulic Design Information Sheet
Name: La Costa Greens Date: 03/24/04
Location: 1945 Dove Lane
Building: New •. . System No. 1-head
Contractor: Lifeguard Fire Protection, Inc. . Contract No.
Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP4
Construction: 0 Combustible [] Non-Combustible Ceiling Height 8'-0" Ft.
Z NFPA13:
NFPA 231
Other (Specify)
Specific Ruling
SYSTEM DESIGN
O Light Hazard Ordinary Hazard Group
[I NFPA 231C: Figure:
Residential Made By
10203 D Extra Hazard
Curve:
Date
Area of Sprinkler Operation 1-head Svsteni Tvne
Density .10 Z Wet 0 Dry 0 Deluge 0 Pre-Action
Area Per Sprinkler 18'x 18' SpriniderorNozzle
Hose Allowance GPM: Inside 0 . Make Tyco Model LFII
Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9.
Rack Sprinkler Allowance n/a Temperature Rating 155
CALCULATION SUMMARY
GPM Required 17.68 PSI Required 31.73 At City Connection
"C" Factor Used: Overhead 120 Underground 150
WATER SUPPLY
Water Flow Test Pump Data Tank or Reservoir
Date & Time 10/17/03 10:45am . Rated Capacity n/a Capacity n/a
Static PSI 72 At PSI n/a Elevation n/a
Residual PSI 64 Elevation n/a
GPM Flowing 1480 Well
Elevation 190' . Proof Flow n/a GPM
Location Point of connection at existing main in Dove Lane
Source of Information Carlsbad Fire Department
:.I,)&,) i i'TItl
Commodity Class
- Location
-
Storage Height Area - Aisle Width
Storage Method: Solid Piled % Palletized % Rack
I
Rack
O Single Row 0 Conventional Pallet
0 Double Row 0 Slave Pallet
O Multiple Row 0 Open
Flue Spacing In Inches
Longitudinal Transverse -
Horizontal Barriers Provided
[J Automatic Storage 0 Encapsulated
0 Solid Shelving 0 Non-Encapsulated
Clearance From Top of Storage to Ceiling
Ft. In.
-
La Costa Greens Bldg 03 1-head Caic Sigma Dynamics Corporation 7700 8uelvI Demand Graph
I
Mergin
Pressure 48.57 Psi
c,4131.610 GPM__=
--
". U1R_
- -
-
-=---------- -- -
__ - iii• --
- iu•au
I iiiu
F
-- I...
Water Flow (I3FM)
System Demand..
Sprinkler Demand
Additional Flows
Hose at Source
Total Demand
16.22 PSI
16.22 PSI
5 17.88 GPM
0.00 GPM
0.00 GPM
5 17.68 GPM
Water Supply..
Static 64.80 PSI
Residual 57.60 PSI
Elevation 0.00 PSI
5 1480.00 GPM
SUBMITTAL SERIAL NO.: 2932HY4 . 03-09-2002 PAGE 1
La Costa Greens
Building #8 thirdfloor 1-head calculation
FLOW TEST RESULTS.
Water Supply
STATIC 64.80 PSI
RESIDUAL 57.60 PSI @ 1480.00 GPM
CITY PRESSURE AVAILABLE AT 17.7 GPM 64.80 PSI
SUMMARY OF SPRINKLER OUTFLOWS
ACTUAL MINIMUM .
SPR FLOW FLOW KFACTOR PRESSURE
164 17.68 17.00. 4.90 13.02
T OTAL WATER. REQUIRED FOR SYSTEM 17.6:8: GPM
TOTAL WATER REQUIREMENT 17.68 GPM
PRESSURE REQUIRED AT 0 . 16.22 PSI
MAXIMUM PRESSURE UNBALANCE IN LOOPS 0 . 00 PSI
MAXIMUM VELOCITY FROM 150 TO 151. 5.96 FPS
SUBMITTAL SERIAL NO:2932HY4 03-09-2002-PAGE 2
La Costa Greens
Building #8 third floor 1-head calculation
Location Flow Pipe Fittings Equiv Friction Pressure
in Size & Length Loss Summary
From To GPM IN Devices: Ft PSI/Ft PSI
160 1.4 1.101 L 13.00 C=150 PT 13.02(164)
Q . 17.68 F=DPV/2E F 11.00 PE 0.22
AO . T 24.00 0.0542 PP 1.30
153 160 1.101 L .32.00 C=150 PT 14.54 (160)
Q 17.68 F=E,DPV,2E/DPV,E F 22.00 PE 0.00
BNi T 54.00 0.054.2 PF 2.93
PT 17.47 (153) ------------------
150 151 1.101 L 1.75 C=150 PT 26.83 (151)
Q 17.68'. F=T/E: F 10.00. PE 0:..32
BN T 11.75 0.0542 PP 0.64.
PT 27.79 (150) ------------------
8 7 7.758 L 22:0.00 C:=:150 PT 16.2:2 C, 7)
Q 13.36 F=GV F' 6.04 PE 0.00
LU T 226.04 0.0.000 PP 0.00
3 8. 7.758 . L 158.0:0: C=.150: PT 16.22( 8)
Q 1.3.36: F=GV,EE/GV,T F 78.57 PE 0.00
LU T 236.57 0.0000 PF 0.00
1 3. 7.758 L 1.00 C=150 PT 16.2.2 C 3.)
Q. 13.3.6 F=O F 0.00 PE: 0.00.
LU T 1.00 0.0000 PF 0.00
PT 16.22 ( 1) ------------------
67 7.758 L 623.0.0 C=150. PT 16.22(7)
Q 4.32 F=EE,GV/EE,GV,2EE. F 66.44 PE 0.00
LU T 689.44 0.0000 PP 0.00
5 6 • 7.758 L 415.00 C=150 PT 16.22 C 6)
Q 4.32 F=GV,2EE./2BE: F 60.40 PE 0.00
LU • T 475.40 0.0000 PF 0.00
7-.758 L 174.00 C=150 PT 16.22 C 5.)
Q 4.32 F=O.. P 0.00 PE: 0.00
LU T 174.00 0.0000 PP 0.00
2 4 . 7.758 L 596.00 C=15•0 PT 16.22 '('.4.)
Q. 4.32 F=T,GV,4EE/Gv,2E'E, F 146.52 PE: 0.00
LU T 742.52 0.0000 PP 000
1 2 • 7.758 L 1.00 C=150 PT 16.22 C 2) Q 4.3.2 • . F=0 F 0.00 PE' 0.00 LU T 1.00 0.0000 PF 0.00
PT 16.22 ( 1)
99Oe0O'p
L 10.00 C=150 PT 17.46 (153)
F=DPV F 1. Dolt PE 4.33
T 11.00 0.0542 PP 0.60
L 9.00 C=150 •PT 22.39 (152)
F=DPV F 1.00 PE 3.90
T' 10.00 0.0542' .PF .0.54
PT 2-6..83 (151)
L 63.00 C=120 PT 27.79 (150) F=T,. SE F 50., 00 PE, -0..87
T 113.00 0.0028 PP 0.32
L 63.00 C=120 PT 27.24. ( 18) F=T/T F 23.20 PE 0.00
T 86.20: 0.0028PF 0.24
152 153 1.101
Q 17.6:8.
FRI.
151 152 1.101
Q 17.68
FRI
------------------
18 150
Q 17.6,8
17 18
Q 17.68
2.203
FM:
2.203
FM
SUBMITTAL SERIAL NO:2932HY4
La Costa Greens
Building #8 third floor 1-head calculation
Location Flow Pipe Fittings Equiv
in Size & Length
From To GPM IN Devices Ft
03-09-2002 PAGE 3
Friction Pressure
Loss 'Sununary
PSI/Ft PSI
16 17
Q 17.68
15 16
Q 17.68
11 15
Q 17.68
10 11
Q 17.68
9 10
Q 17.68
7 9
Q 17.68
------------------
0 1'
Q 17.68
3.314 L 20.00 C=I20 PT 27.48 ( 17) F=8E F 58.40 PE 0.87 FM T 78.40 0.0004 PP 0.03
3.314 L 116.00 C=120 PT 28.38 ( 16) F=2E/T F 33.50 PE 0.00
FM 'T 149.50 0.0004 PF 0.06
3.314 L 7.58 C=120 PT 28.44 ( 15)
F=V,E F 28.85 PR 3.28 FR
,
T 36.43; 0.0004 PP 0.01
4.280 L 7.00 ' C=140 PT 31.73 ( 11) F=E F 17.92 . PE. -.0.00 UN T 24.92 0.0001 pp 0.00
4.266 L ' 37.00 C=150 PT 31.73 ( 10) F=T F 38.42 PE 0.00 UN T 751.4.2 0.0001 PP 0.01
4.266 L 71.00 C=150 PT :31.74 ( 9) F=T,GVDDC/3E F 99.89 ' PE -27.30 UN T 17.0. 89 0.0001 PP 0.02
411 Watts 909 RPDA '11.77
PT 4.46 ( 7)
7.758 ' L 1.00 C=1.50 PT 1.6.22 (' 1). F=0 F 0.00 PR 0.0.0 UN , T 1.00 0.0000 PP 0.00
PT 16. 22 0)
A60~02-2o
hIATERIAL LDATA.5UE3r""1177AL
Lo Cos-ro Greens
Building #3 1945 EOve Lone
Carlsbad, CA.
LIFEGUARD FIRE PROTECTION, INC.
205 TEMPLE HEIGHTS DRIVE, STE. F
OCEANSIDE, CA 92056
70-800-9997 • 70-800-4813 FAX
El 11
DOUBLE CHECK DETECTOR ASSEMBLY
BACKFLOW PREVENTION
U.S Patent No. 4,989,635 • U.S Patent No 5.101.888 Physical Properties U.S. Patent No, 5,365,166 • UA Patent Na 50%0,441
U.S. Patent No.5.392.803 • U.S Patent No.5.503,176 Size of Mainline 2-1/2",3,4",6',8', & 10"
Max. Working Pressure 175 PSI (1200 KPa)
Hydrostatic Test Press. 350 PSI (2400 KPa)
Temperature Range 320 F to 1400 F
(0° C to 600 C)
End Connections Flanged ANSI B16.1
Class 125 a,
as
Materials
Main Valve Body Ductile iron Grade 65-45-12
Coating Fusion epoxy coated
internal and external
AWWA C550-90
MODEL 876V DOUBLE CHECK DETECTOR
(Shown In vertical position)
Shut Off Valves OS & V resilient wedge
gate valves AWWA C509
Trim Bronze
Elastomer Discs EPDM
Spring Stainless steel !d I
MODEL 876187ev DOUBLE CHECK DETECTOR
Installation Views (Shown In standard orientation)
t
18" I ndn 18ndn
Suppoit ilshudby cultomer) ,alvewclgtd only.
FLOW
Standard orientation (Model 876"/876V)
* Note-Model 876 does not include grooved end coupling.
Recommended minimum clearances from permanent structures for
ease of testing and maintenance.
Vertical orientation (Model 876V)
LSu1ER
8761876V Materials of Construction
ITEM DESCRIPTION MATERIALS ITEM DESCRIPTION MATERIALS ITEM DESCRIPTION MATERIALS
1 Body A536 GR 6545-12 8 Lower Spring Retainer 8584 Alloy C83800 26 Gasket EPDM ASTM D2000
2 Cover A536 GR 6545-12 9 Spring Stem 30455 35 0-ring EPDM ASTM 131999
2.1 0-ring EPDM ASTM D2000 9.1 Elastic Stop Jam Nut 18-8SS 35.1 Back UpRing AcetatResin
2.2 • Cap Screw Plated Steel 10 Spring A313 Type 631 SS 36 Cover 6584 Alloy C83600
2.3 Hex Nut Plated Steel 10.2 Spring Shim Metal Resin 40 Bell Valve B584 Alloy C83600
2.5 Cover (w/o holes) A536 GR 65-45-12 10.3 Spring Shim Metal Resin 41 Nipple Brass
3 Seat Ring 0524 Alloy C83600 11 Spring Guide B130 Alloy C22000 42 Gate Valve (OSSY) AWWA C509
3.1 Gasket EPDM ASTM D2000 12 Upper Spring Retainer 8584 Alloy C83600 43 Bulkhead Fitting B584 Alloy C83600
4 Arm B584 Alloy C83600 12.1 Bushing Spring Stem Acetal Resin 43.1 Bulkhead Fitting 6584 Alloy C83600
4.1 Bushing-Swing Pin Acetal Resin 13 Pivot Bearing - B585 Alloy C83600 44 Bulkhead Filling B584 Alloy C83600
4.2 Swing Pin 304 SS 14 Flange Gasket Rubber/Fabric 45 Gasket EPDM ASTM 02000 5 Retaining Clip 302 SS 15 Bearing Socket Metal Resin 45.1 Gasket EPDM ASTM 02001 5.1 Retaining Clip 302 SS 16 Hex Jam Nut Is-ass 46 Washer 836 Alloy 260 6 Check Disk (2-1I2 - 8) EPDM Coated GR. 45 Capsuew (10 Only) 18-8 SS 46.1 Washer 636 Alloy 260 Ductile Iron wi type 17 Washer 3028S 47 Nut 6584 Allay C83601 304 SS 18 Flange Nut Plated Steel 471 Nut 6584 Aliloy C83602 Seat Disc (10 Only) Silicone ASTM D2000 18.1 flange Nut Plated Steal 60 Identification Plate 836 Alloy C26000 6.1 • Disc Holder (10 Only) ASTM A743 304 SS 19 Cover A36 Sti. Epoxy Coated 61 Identification Plate 836 Alloy C26000 6.2 Disc Retainer (I(r Only) ASTM A743 304 SS 24 Bolt Plated Steal 62 Drive Screw Stainless Steal 6.3 Capscrew (10 Only) 18-8 SS 24.1 Washer Plated Steel 70 Clamp 876V Only AWWA C608 7 Load Pin 3045S 25 Boll Plated Steel
Not Shown
2
Note: The Model 876V is shipped in the
standard (N-Shape) orientation as shown
below.
arooved and
CIS &Y
Side View
Model 876V Model 876V
Standard Orientation Vertil Odataticn
Dimensions Approximate
El Net.
Os&Y OS&y
Size A B C OPEN F G H J K M (Lbs.)
2112" 121h 25l4 24'14 1618 166!. 6'I' 111h 312 1351a 271!. 230
65 317.50 654.05 615.95 415.93 422.28 158.75 292.10 88.90 346.08 692.15 104.33
12112 254 2414 2214 1618 6114 11'12 3114 1411. 2814 300
80 317.50 654.05 628.65 565.15 422.28 158.75 292.10 95.25 358.78 717.55 136.08
14 27"!. 261 231I4 17½ 7 13 4'la 15112 31 330
100 355.60 708.03 679.45 590.55 450.85 177.80 330.20 114.30 393.70 787.40 149.69
6" 16 32'I4 32½ 3011. 214h 8 13 5112 163!. 37114 520
150 406.40 819.15 819.15 765.18 547.9 203.20 330.20 139.70 473.08 946.15 235.87
8" 18'12 371I2 36216 373/4 2411. 9114 141/2 6314 2014 41112 860
200 469.90 952.50 923.93 958.85 631.80 234.95 368.30 171.45 527.05 '1054.10 390.09
10" 21 42112 40!. 48 271!. 10 15 8 24 48 1460
250 533.40 1079.50 1035.05 1219.20 698.50 254.00 381.00 203.20 609.60 1219.20 662.24
Weights do not include risers or optional valve setter.
Note: Dimensions shown are nominal. Allowances must be made for normal manufacturing tolerances.
Refer to Specification Sheet SS VS for details on valve setter.
MTAST1EJRJ -J t L.
Application
Non-Health Hazard Fire Sprinkler Systems
Flow Orientation
Standard orientation is inlet flow vertical up, outlet flow
vertical down. Vertical orientation is inlet and outlet flow
vertical up.
Options
D Valve Setter with MJ x FL, MJ x MJ
or FLxFL ends
Agency Compliance
Approved by the Foundation for Cross
Connection Control and Hydraulic Research
at the University of Southern California.
ASSE (Std. 1048)
ANSI/AWWA (C510-89)
CAN/CSA (B64.5)
FM
UL
cUL
Less gate not FM approved.
Less gate not UL listed unless installed wIth UL listed
gated valves.
Model 87€/876V Flow Curves
I
I I II I II I II II II .11 .11 III lI II
. ____________________
I Ij. I 500 1000 1500 2000 2500 3000
GPM
4', 10"
18
16 ca .14
, 12
510 -J
56
2
Bi
16
14
12
g 10
6
I 2
B
0 100 200 300 400 500 600 700 0 1000 2000 3000 4000 5000 GPM GPM
A-Vertical orientation (model 876V) The 6" and 100 flow curves in the standard orientation
B-Standard orientation (model 876) include the FEBCO valve setter model 611.
FEBCO Backif ow Prevention
P.O. Box 8070. Fresno, CA 93747-8070
559 252-0791 Fax 559453-9030• www.cmb-Ind.com
55876V 01101 vIttO1 MBIndiVa blc.
CNN Industries, Inc.
AL -lit
ISO 9001 Certified
Super Floe/DynamFlow@
.Aigh Strength Steel Pipe-,
The original high-strength IightwalI sprinkler pipe with hydraulics superior to Schedule-10.
Super Flo/Dyna-Flow pipe is the "original"
high-strength lightwall sprinkler pipe.
Super Flo/Dyna-Flow has outstanding
hydraulic capabilities and is recognized
as the most popular alternative to
Schedule- 10 pipe. Lightweight, easy to
cut and easy to handle for installation.
Super Flo/Dyna-Flow is a valuable
addition to any fire protection system.
Superior Hydraulics
With an inside diameter of up to 11%
larger than Schedule-40 and up to 7%
larger than Schedule-10, Super FbI
Dyna-Flow pipe hydraulics are exceptional.
' get I.D.s enable SuperFlo/Dyna-Flow,
id related components, to be down-
sized within the system, thus increasing
the potential for job cost savings. For
complete Hazen-Williams charts, refer to
"Super Flo/Dyna-Flow Hydraulic Data
Tables."
Coatings & Fabrication'
Super Flo/Dyna-Flow products are coated
with an environmentally approved and
specialty formulated modified-acrylic or
water-based coating. This durable coating
is paintable. The black coating acts as
an exceUent primer and is resistant to
weathering and U.V. degradation from
outdoor storage.
Metallurgical properties provide excellent
fabrication characteristics for end prep
finishes, welding and roll grooving. No
.-'tcial process or equipment are needed
fabrication and installation.
.5
' allied
njaa & CONDUIT
Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Litt Wt/Lift Wt/Lift
NPS I.D. H20 Filled Lift 21' 24' 25'
1.191 0.830 1.31 91 1586 1812 1888
*25 30.3 1.2 1.95 91 719 822 856
1 1/4" 1.536 1.059 1.87 61 1356 1550 1615
32 39.0 1.6 2.78 61 615 703 733
x 1 1/2" 1.728 1.667 2.71 61 2135 2440 2542
40 43.9 2.5 4.03 61 968 1107 1153
2.203 2.104 3.79 37 1634 18681946
*50 56.0 3.1 5.64 37 741 847 883
x 2 1/2" 2.703 2.564 5.10 30 1615 1846 1923
*65 68.7 3.8 7.59 30 733 837 872
3.314 3.387 7.18 19 1351 1544 1608
*80 84.2 5.0 10.69 19 613 700 729
4.310 4.473 10.86 19 1784 2039 2124
*90 109.5 6.7 16.16 19 809 925 963
X 6" 6.403 7.714 21.70 10 1620 1851 1928
*150 162.6 11.5 32.29 10 735 840 875
Super Flo/Dyna-Flow pipe is
manufactured to meet ASTM A-
795 '1pe E, Grade A and is in
compliance with NFPA-13 and
NFPA-14. All sizes of Dyna
Flow/Super Flo are UL Listed,
FM Approved and ULC Listed.
(@ 0 @
Listed Approved Listed
SuperFlo/Dyna-Flow is UL/ULC
Listed for use with roll grooved,
plain-end couplings, and welded
joints for wet, dry, preaction and
deluge systems. h is FM Approved
for roll grooved, plain-end, and
welded joints for wet systems.
Refer to appropriate documeruation
for up-to-date listing and approval
information. Super Fbo/.Dyna-Flow
is now available "hot-dip"galvanized
and has been specifically approved
by FM for dry systems uses.
Lightweight and easy to install,
resulting in more efficient use of
your freight and labor dollars.
Provides stability needed to
comply with standard hanger
spacing (15 ft O.C.) per NFPA.
Available in Standard lengths
for your convenience, or can be
ordered in custom lengths
upon approval.
Fast cutting and-welding, as well
as easy roll grooving and end
preparation.
Available in Factory roll grooved
form for quicker shop turnaround.
Clean, durable mill coating
provides longer "shelf life" and
acts as an excellent primer for
custom paint applications.
16100 S. Lathrop 11350 Norcorn Rd. 2525 N. 271h Ave. Customer Srv!:
Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 1-800-797-6210
Fax 70,9-339-1806
I Submittal Data Sheet
Super 4O7Dyna-Thread'
Full Line Sch-40 Replacement
Super .lWDyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler
pipe industry. It combines the safety and longevity of traditional Sch.40 pipe with quality and
superior hydraulic advantages.
Comparison to Schedule 40 Super 40/Dyna-Threads inside diameter is up to 3.6%
larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow
pipe. down sizing often occurs. Super 40/Dyna-Thread is fully listed and approved UL. ULC, and
FM for lire sprinkler applicadons. The lire expectancy of Super 40/Dyna-Thre3d and Sch-40 are.
equal based on the calculated wall thicknesses per UL (see CRR). The Consistent quality of steel
used to make Super 40/Dyna-Thread facilitates smooth threading and lower maintenance costs.
'f Ile etenot' ut Super 4O/D'nu-Thread is protected by a clean, durable mill coating for extended
i.lt' life and CI5V paint application. With its increased strength and lighter weight. Super40/
D na-Thread reduces installation fiuiiiie and is ideal t'or retro-tit applications. Corrosion
R.iiance Ratio tCRRt is a UI. (Underwriters Laboratory) term for the estimated life expectancy
01 a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread,
asumed to be the weakest point of the pipe length. Super 40/Dyna-Threact and Sch-40 have the
calculated wall thicknesses it this point and are both assigned the same CRR oft .00.
Comparison to L.W.T. Pipe More wall thickness at the thread (CRR1.00) gives
Super 40/Dyna-Thread better life expectancy than lighiwall threadable pipe joints. Unlike
lighiwall threadalile pipe. Super 40/Dyna-Thread has no thread sauge warning. Super 40/
D vna-Thread is approved for standard hanger spacing (15 ft. 0.6. can be used as earthquake
sway Iracing. and is safe to use as drops. Super 40/Dyna-Thread is safer to weld on than many
zinc-coated lighiwall threadable pipe products. Super 40/Dyna-Thread is more widely accepted
than lighl%%'all threadable where Sch-40 is specified.
Spèçifications & Approvals
Super4O/Dyna-Thread pipe is manufactured to
meet: ASTM A 135. Grade A and is in compliance
ith NFPA- 13. All sizes of Super 40/Dyna-Thread
are rated at 300 psi working pressure. Super 40!
Dma-Thread is UL Lind ULC Listed for wet, dry
aitd pre-action sprinkler systems and FM Approved
fur use in wei systems. Super 40/Dyno-Thread can
he "hot-dip" galvanized to meet FM requirement
fur dry ysterns. Super 40/121yna-Thread is approved
fur all threaded couplings and selded outlets and is
suitable for all roll-grooved, and plain-end fittings.
(See listine information).
Stamp Here
Product
NPS
Nominal
1. D.
Wt/Ft Wt/Ft
H20 Fitted
PCs/
Lift
Wt/Lift
21'
Wt/Lift
24'
Wt/Litt
2 ,
1" 1.080'1,330 1.75 70 1955 2234 2327
*25 27.4 2.02.60 70 887 , 1013 1056
1 1/4" 1.408 1.870 2.54 51 2002 2288 2384
*32 35.8
-
2,8 3.78 51 908 1038 1083.
Lluod
L
Approyod LIsWd
x 1 1/2"
*40
1.639
4L6
2.290
3.4
3.22
4.79
44
44
2115
959
2418
1097
2519
:1143
x2" 2.104 3.050 4.57 30 1921 2196
*50 53.4 4.5 6.80 30 871 996
2287
1037
Aincricn Tube and Pipe was acquired by Allied 'flibe and Conduit on February 1, 1997. The engineered lightwall and standard wall i'amily of prodticts although they
have dilTerem names are the same in all respects with regard to strength, Weight, bundle count, listings and approvals. For example, Dyna.Flou' atid Super Flo are the
same product as are Dyna 'Fhread and Super 40. XL is manufactured with Exterior galvanized coating. I3LT is manufactured with Black lacquer coming.
Project: Prolect: Sprinkler Conti-actor Date:
Engineer: Specification Reference: System Type:
Locations: Comments:
Flow Data
Friction Resistance
The chart expresses the frictional
resistance of various Victaulic
filtings as equivalent Feet of
straight pipe. Fittings not listed
can be estimated from the data
given, for example, a 221/2" elbow
is appluldmately one-half the
resistance of a 450 elbow. Values of
mid-sizes can be interpolated.
TIPS ECIIf
I OOVED FITTINGS I4
Grooved IPS Fittings
Victaulic fittings are designed specifically for use
in grooved piping systems.
Victaulic offers a broad line of
fittings in sizes through 24'
(600 mm) in a variety of straight
and reducing styles. Most standard
Fittings are cast of durable ductile
iron to precise tolerances. Victauhc
standard fittings pressure ratings
conform to the ratings of Vicraulic
Style 77 couplings.
All fittings are 'supplied with
grooves or shoulders to permit last
installation without field
preparation. The grooved design
permits flexibility for easy
alignment. These fittings are not
intended far use with Victaulic
couplings far plain end pipe (refer
to page 55 for fittings available for
plain end applications).
Fittings are provided in various
materials including malleable iron,
ductile iron, steel or segmentally
welded steel depending on styles
and size. Fittings re painted
orange enamel with galvanized
optionally available, contact
Victaulic for details.
Victaulic fittings are designed
specifically for use in grooved
piping systems. Fittings are
provided grooved or with
shoulders conforming to standard
steel pipe outside diameters. When
connecting wafer or lug-type
butterfly valves directly to
Victaulic fittings with 741 or 743
Vic-Flange6 adapters, check disc
clearance dimensions with I.D.
dimension of fitting.
Request 07.01.
Alternate Materials
Stainless Steel - Grooved end
fittings are available in Schedule 10
Type 316 stainless steel (Schedule
5, 40 and Type 304 optionally
available) in various sizes. Fitting
cencer-to-end dimensions will vary
depending upon r',qe and
schedule.
Request 17.04 for details.
Aluminum -Grooved end fittings
are available in aluminum alloy 356
T6, in sizes from 1 -
50 (25 - 200
mm). Request 21.03 or contact
Vicraulic for details.
Alternate Styles
EndSeal "ES" Fittings -
EndSeal fittings are available in 2 -
12(50- 300 mm) for use with "ES"
grooved pipe and HP-70ES
EndSeal or FireRTM couplings.
"ES" fittings are painted green for
easy identification. EndSeal (and
standard) fittings may be easily
internally coated (by others) for
severe service requirements.
Always specify "ES EndSeal
fittings" when ordering.
Request 07.04 for information on
EndSeal fittings.
Fittings Machined for Rubber
or Urethane Lining (MEL) --For
severe abrasive services, Vicraulic
fittings may be rubber or urethane
lined (by others). Lining may be
inside diameter/end (abrasion
resistance) or wrap-around
(corrosion and/or abrasion)
machined.
Request 25.03 or contact Victaulic
for specific details.
Pipe Pipe -
Inches/min Equivalent Feel/meters of Straight Pipe Inches/mm Equivalent Feel/melers of Straight Pipe
- 900 Elbows 45° Elbows Tees 90° Elbows . 45° Elbows Tees
No. 100 No. 110 No. 100 No. 110
No.10 1'/20 No. 11 1½0 No.10 1½D No.11 1½0
Nom. Actual Sid. Long Sid. Long Worn. Actual Sid. Long Sid. Long
Size Size Radius Radius Radius Radius Branch Run Size Size Radius Radius Radius Radius Branch Run
1 1.315 1.7 - 0.8 - 4.2 1.7 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0
25 33.7 0.5 0.2 . 13 0.5 150 1683 30 2.3 15 0.9 76 30
2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 6.500 9.6 -. 5.0 - 25.0 60.3 1.1 08 OS 03 26 ii
10.050 151 2.9 - 15 7.6 30
31: 3.000 4.3 -. 2.1 -. 10.9 4.3 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0
76.1 1.3 .. 07 . 33 13 200 2191 4.0 3.0 2.0 1.2 101 40
3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0
80 88.9 15 12 08 05 40 1.5 P50 273.0 52 37 2.5 1.5 12.5 5.2
4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 100 1143 21 15 10 06 49 2.1 300 3239 6.1 4.4 30 18 15.2 61
1 4 /4 1: 4.250 6.4 - 3.2 - 15.3 6.4 14 14.000 It 23.0 ft 18.0 60.0 17.0 106.0 1.11 09 47 20 350 3556 ii 7.0 0 5.5 1113 5.2
5 5.563 8.5 - 4.2 -. 21.0 8.5 16 16.000 ft 26.0 If 20.0 70.0 20.0
125 14 1. 3, 26 . 1.3 -. 6.4 2 400 4064 is 79 a 6.1 213 61
5.250 8.1 - 4.1 - 20.0 8.1 18 18.000 41 29.0 ft 23,0 80.0 2.0 51A4 133025_1 .. 6.2 a5 450 457.0 fr 8.6 5 70 24470
5.500 8.5 - 4.2 - 21.0 13.5 20 20.000 It 33.0 It 26.0 90.0 25.0 2.6 - 1.3 64 2.6 500 508.0 is 10.1 is 7.9 27.4 7.8
61: 6.250 9.6 - 5.0 -. 25.0 10.0 24 24.000 II 40.0 It 30.0 30.5 34.0 159.0 1 2.9 .- 15 . 76 30 600 6100 6 12.2 a cii 93 10.4
H Contact Victaulic for clelails.
0.0. Dimension.
14
Style 77
Standard
Flexible Coupling
Style 77 couplings are designed
with cross-ribbed construction to
provide a strong component for
pressure piping systems. Sizes
% -12" (20-300 mm) are two-piece
housings. Sizes 14 - 22"
(350 - 550 mm) are cast in four
identical segments, with larger
sizes cast in six segments.
Request 06.04.
vzcso
V.-12" Sizes 14-22" Sizes
1zI4. zr
1 01
Mr.,"OOVE..,6" PLINGS
Style 07 The unique angle-pad design of
Zero_Flex® Rigid Coupling ZeroFlex® Style 07 adjusts to
standard pipe and roll or cut
Q groove tolerances, positively
clamping the pipe to resist flexural
and torsional loads. Wider key
section (ills more of the groove
area.
Request 06.02.
Z I
X/
--11 Z r
M ()X/
2- 12' Sizes 14- 16" Sizes 18- 24" Sizes
mom*
Size
Max.
Work Press. Dimensions - Inches/mm WgIEach
X V Z Inches/inni PSI'/RPa Lbsikg
750 2.45 4.13 1.88 1.6
62 411 it
11/1 750 2.60 4.00 1.88 1.6
3.' :,I,i tti 10? 411 1 I) 7
114. 750 2.94 4.61 1.88 1.6
413 ,•i -'
2 750 3.19 5.44 1.86 2.3
!10 V!i :11 I'll .15 I (1
2½ 750 3.68 6.13 1.88 2.3
%is :1j ¶15 1:6 .i( 1
750 4.25 5.75 1.86 3.6 31: !)1 '011 146 .0 1. 6
3 750 4.56 6.81 1.88 3.1
I 1,3 (73 4131
4 750 5.81 8.25 2.06 4.8
101)
750 5.56 7.44 2.06 5.2 4 1: :;i, i-i
5 750 7.06 9.75 2.06 7.1 1.':. -1:5 IN 24i 5' .1.'
700 6.36 9.18 2.06 7.4 51/4 1: "II.'! 174 5;1
700 6.94 9.42 06 7.6
5 /2 , , 1 --
6 700 8.00 10.75 r2.06 8.7
'11125 2(1:1 :'
700 7.85 10.1806 9.2 61' U.' '99 .' MI ? 4
700 8.00 10.75 2.06 7.2 61/2.. .1. .16/5 "o:i '3
8 600 10.25 13.50 2.50 14.9 .11:10 ';iO ..I3 Ii
10§ 500 12.88 16.75 2.56 25.0 65 1' 3
12§ 400 14.88 18.50 2.56 28.2
ii
14 300 16.19 19.75 2.94 32.8
.1St) .'t),,:, 4 1 51'.' 7b ('13)
16 300 18.38 21.75 2.94 41.2
.10(1 :'UtlS .lt' :':5 75 16 7
18 300 20.69 23.88 3.06 54.2 titlt; 79 :14 6
20 300 23.00 27.38 3.06 67.2 :'ot;s :,114 01k, 713 J) 5
24 250 27.13 31.50 3.13 76.2 0,11) 172:, )tXI 79 34 13
u.0 Dimension. - lierer to notes on page t 9 PvaiIaDle to J.I.S. dimension
Size woi'ess. Dimensions - Inches/innt Wch
X V Z Inches/nim PSr/IIPa Lbs/kg
V4 1,000 2.13 3.63 1.75 - 1.1
:.4 9.' 1.1 ii'
1 - 1,000 2.36 3.88 1.75 - 1.3
6900 60 :15 .11 11 (1
116, 1.000 2.63 4.63 1.75 - 2.0
L1It10 67 115 .11 119
1½ 1,000 3.00 5.00 1.75 - 2.1
10 i: I-i 'I')
2 1,000 3.63 5.63 1.75 - 2.6
143 II
21A 1,000 4.25 6.25 1.75 - 3.1
31. 6900 IM i 5,1 .14 1 .1
31: 1,000 4.31 6.31 1.75 - 3.6
to ic,, 14 1 (1
3 1,000 5.00 7.00 1.75 - 3.5
110 IIIIX.) i: i:;; .14 1 I
31/2 1,000 5.63 8.00 1.75 5.6 So 6900 113 :o.; .1.1 ' S
4 1,000 6.38 8.50 2.00 6.6 S I :111
1.000 5.88 8.06 2.06 - 7.0 41/i 1: 1ILt '0:,
5 1,000 7.63 10.25 2.00 - 10.6
5½ 1: 1,000 7.34 9.20 2.06
i3'Jfl(, 15,3 .!J'l
5/21- 1,000 7.60 9.44 2.06 - 11.0
,uixi 193 .'.iO :6'
6 1.000 9.00 13.50 2.00 - 11.8
(10(11) :'?9 21' 10 :' -I
1.000 8.50 10.38 2.06 - 13.2 1 61/4 1:- 2)(j
6/21: 1,000 9.19 11.50 2.06 - 13.2
11900 23:3 .-'t)2 :'2 6 11
800 11.38 14.50 2.38 - 20.1
Ivi 3!,tit) .365 60 51
10§ 800 13.50 16.75 2.50 - 28.3
143 -125 64 I? (I
12 § 800 15.50 19.00 2.50 - - 34.2 30,', 35-JO .194 ((U 6.1 Ill:.
14 300 16.63 20.00 2.88 - 35.6
:bo 'OtIS 4.':l SOil ::3 it; I
.15 300 17.88 21.25 2.88 48.8
-(fl-I .-lO
16 300 19.00 22.36 2.88 51.1
.111:4 i(Iz; :3 23
18 300 21.25 24.38 3.13 - 64.4
-'59 2Ot35 :,4(1 611 '5
20 300 23.50 27.50 3.13 - 91.2
- 09() 9 411
22 300 25.63 30.00 3.13 - 92.0
631 79 417
24 250 27.63 31.38 3.13 - 94.0 130t) 1725 70;' :9'
O.D. Dimension. Rater to notes on page 7. § Available to J.I.S. dimension.
Size Range - 1/4 thru 1-1/2 inch rod in 10,-0"
lengths.
Material - Carbon Steel
Maximum Temperature- 750°F
Finish - Plain, Electro-Galvanized, and Stainless
Steel.
Order By - Figure number, rod diameter, and
finish.
MAX. REC. LOAD LBS. APPROX.
ROD FOR SERVICE TEMPS WEIGHT
SIZE 650°F 750°F PER 100 FT.
1/4 240 215 12
1/2 1130 1010 .53
3/4 2710 2420 123
JJ37799(
4960 4420 222
J3
1-1/2 11630 10370 510
ILC
INCORPORATED
CORONA. CA • (909) 737-5599 53
FIG. 99
ALL THREAD ROD CUT TO LENGTH
Size Range - 3/8 thru 7/8 inch rod in 1 inch
increments.
Material - Carbon Steel
Maximum Temperature- 750°F
Finish - Plain, Electro-Galvanized, and Stainless
Steel.
Order By - Figure number, rod diameter, rod
length, and finish.
MAX. REC. LOAD LBS.
ROD FOR SERVICE TEMPS.
SIZE 650°F 750°F
3/8 610 540-
V2 1130 1010
5/8 1810 1610
3/4 2710 2420
7/8 3770 3360
FIG. 100
ALL THREAD ROD FULL. LENGTHS
Irico Ii P Ofl A
CORONA. CA • (909) 737.5599 15
FIG. 2 ADJUSTABLE RING HANGER
FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE
Size Range - 1/2 thru 6 inch pipe.
Material - Carbon Steel, Mu. Galvanized to G-90
specification.
Function - For general piping purposes. Knurled
swivel nut design permits hanger adjustment after
installation. Spring tension on swivel nut holds it
securely in hanger before installation. Swivel nut
easily removed.
Approvals - Underwriters' Laboratories listed and
Factory Mutual Engineering approved. Conforms
to Federal Specification WW-H-171E, type 10, and
Manufacturers Standardization Society SP-69,
type 10.
Maximum Temperature - 650°F
Finish - Mil. Galvanized and Stainless Steel.
Order By- Figure number and pipe size.
PIPE ROD STOCK
MAX.
REC.
APPROX. WEIGHT PER 100
FIG. 2
SIZE SIZE A B C SIZE LOAD LBS. FIG. 2 NFPA
1/2 3/8 3-1/8 2.5/8 1-3/8 16gax I 400 17 17
-W
3/8 1 3/8 3-3/8 2-5/8 1-1/8 16gax1 400 18 18
...........r )j ,'f•.. it 4Ov . ... .
1-1/2 3/8 3-7/8 2-7/6 . 1 169ax1 400 21 21
2 ., J1J4 J.i6a 1 400 -. 2i
2-1/2 1/2* 5-3/4 4-1/4 1-5/8 149ax1.3/16 600 41 40
3-1/2 1/2* 7.3/8 5-1/4 2-1/8 14ga1-3/16 600 52 50
5 5/8' 9 6-1/8 2-1/4 l2gaxl.1/4 1250 97 95
'9 3/8 1/ , 1. '/8 12g 14/4 125Q 13;
3/8" nut (s used when NFPA rod sizin9 s requested.
I/2' nut is used when NFPA rod sizing is requested.
fig 1\l
/'
TO LTC 0
- INCORPORATED
1.20 CORONA. CA • (909) 737-9509
...
.
FIG. 1000
"FAST CLAMP" SWAY BRACE ATTACHMENT
Size Range - Pipe size to be braced: 1" through 8"
Sch. 10 and 40. Pipe size used for bracing: 1" and
1-1/4k Sch. 40 IPS.
Material - Carbon Steel
Function - For bracing pipe against sway and
seismic disturbance. The pipe attachment com-
ponent of a sway brace system: Fig. 1000 is used
in conjunction with a Tolco 900 Series Fitting and
joined together with bracing pipe per NFPA #13*,
forming a complete sway brace assembly.
Features - Can be used to brace Schedules 10 and
40 IPS.
Field adjustable, making critical pre-engineering of
bracing pipe unnecessary.
Unique design requires no threading of bracing
pipe.
Can be used as 4-way riser brace.
Can be used as longitudinal brace.
All steel construction eliminates structural
deficiencies associated with casting type sway
brace fittings.
Comes individually packaged with illustrated
installation instructions - sizes are clearly marked.
Steel leaf spring insert provided to assure installer
and inspector that necessary minimum torque
(5 lb/It) has been achieved.
Application Note - Fast Clamp need not be field
assembled. Position Fast Clamp and tighten two
hex nuts until leaf spring flattens.
*Length of bracing pipe per National Fire
Protection Association, Pamphlet #13, paragraph
A-3-10.3.5: 1" Schedule 40 bracing pipe maximum
7'-2". 1-1/4" Schedule 40 bracing pipe maximum
9'-2".
Approvals - Underwriters' Laboratories listed.
Note - Must be used with Tolco U.L. Listed 900
Series attachment.
Finish - Plain, Electro-Galvanized, HDG, and
Stainless Steel.
Order By - Order first by pipe size to be braced
followed by pipe size used for bracing, figure
number, and finish.
/-D
D-
INCOR P0 RAT 0
118 CORONA. CA • (909) 737.5599
FIG. 910
SWIVEL SWAY BRACE FITTING
Size Range 1 & 1.1/4 inch bracing pipe,
Material - Carbon Steel
Function - For bracing pipe against sway and
seismic disturbances. The building attachment
component of a sway brace system; The Fig. 910 is
used in conjunction with the Fig. 1000 "Fast
Clamp" (or with a Fig. 4A Pipe Clamp), and joined
together with a brace pipe per NFPA #13*.
Features - Universal swivel design allows Fig. 910
to be attached at any surface angle. All steel
construction eliminates deficiencies associated
with casting type attachments.
Application Note - *Length of bracing pipe per
National Fire Protection Association Pamphlet
#13, paragraph A-3-10.3.5: 1" Schedule 40 bracing
pipe maximum 7'-2". 1-1/4" Schedule 40 bracing
pipe maximum 9'-2".
Approvals - Underwriters' Laboratories listed.
Note -The Fig. 910 Swivel Attachment and the Fig.
1000 "Fast Clamp" (or Fig. 4A Pipe Clamp), make
up a sway brace system of U.L. Listed attachments
and bracing materials which satisfies the
requirements of- Underwriters' Laboratories and
the National Fire Protection Association (NFPA).
Finish - Plain, Elec.t.rp-Oalvanized, and Stainless
Steel.
Order By - Figure number, pipe size, and finish.
Note - Specific weight load conditions may require
more than one fastener to the building structure.
hrre attpkrhmpntq mu hp ordered with
D A? nOLE WI - SIZE A B C SIZE E F PER 100
2 1-1/2 3 9/16 2-5/16 2 88
.: 30.6....
V .............
BRECCO Brecco Corporation
) GAUGES
-. GAUGES
FOR USE WITH WET OR DRY
SYSTEMS. GAUGES HAVE A
BRONZE BURBON TUBE
MOVEMENT IN A STAINLESS
STEEL PLATED CASE
(UNLESS OTHERWISE
NOTED). 3-1/2" DIAMETER.
U.L. AND F.M. APPROVED
(UNLESS OTHERWISE
NOTED).
Pefl No. Description - Boxasi
GAAWSS350 AIR / WATER 0. 300 PSI
-60 WI STAINLESS STEEL CASE
GMSS250 AIR W/ RETARD 250 PSI
3-1/2" DIA, WI STAINLESS STEEL 60 CASE
GAWP200 2" RESIDENTIAL GAUGE 300 PSI
100 (NOT U.L. OR F.M. APPROVED)
GMWP360 AIR I WATER W/ PLASTIC CASE 6D
i.8OO543.4194 Fax: 1877.4749248 AR AS REQUIRED breccocorp@earthhnk.net
082000
Told
INCORPORATED
CORONA. CA • (9091737-5599 41
FIG. 51 AND FIG. 52
SIDE.BEAM BRACKETS (CONT.)
H-3(4)
-,L A
-4 B AS A —r ~—iC
FIG. 51 FIG. 52
FIG. 51 for NFPA Rod and Fastener Sizing
- APPROX.
PIPE ROD HOLE SIZE STOCK WEIGHT
SIZE SIZE A B C H-i H-2 SIZE PER 100
1/2 -2 3/8 2 3/4 2 7/16 7/16 3/16x2 35
, 9/6, p7/16 3/3,6x2 84
5-6 1/2 2.1/2 3/4 2-1/2 9/16 9/16 3/8x2-1/2x2.1/2 71
8 2 1/2 3/4 24/2' 11/16 9/i6 3/8x2 1/x 1/2 7Q I
FIG. 52 - 6 Hole Bracket
APPROX.
ROD HOLE SIZE STOCK WEIGHT
SIZE A B C H-i H-2 H-3 SIZE PER 500
3/8x1/2 2 1-1/16 2 9/16 7/16 9/32 3/16x2 35
FIG. 56
TAPPED SIDE BEAM CONNECTOR
Size Range - 1/2 thru 4 inch pipe (3/8 inch rod).
Material - Carbon Steel
Function - Practical and economical bracket used
to support hangers from steel or wood beams. Can
be used with concrete shot-type inserts. Tapped
hole allows easy adjustment of hanger rod.
Approvals - Underwriters' Laboratories listed and
Factory Mutual Engineering approved for 1/2 - 4"
pipe. -
Finish - Plain, Electro-Galvanized, HDG, and
Stainless Steel,
Order By - Figure number and finish.
Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8
inch fastener; 2-1/2 thru 4 inch pipe use 1/2 inch
fastener.
G
E H
IF
DI
~ C,
ROD APPROX, PIPE SIZE HOLE SIZE STOCK WEIGHT SIZE A B C D E F G H J SIZE PER 100
1/2 -4 2.5/8 3/8 1
--
3/8 1-1/16 1-1/8 7/16 9/16 1-1/4 1/4x1 20
tqco /Fire & Building
I Products
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
Series LFII Residential
Pendent Sprinklers
49 K-factor
Customer Service/Sales:
Tel: (414) 570-5000 / (800) 558-5236
Fax: (414) 570-5010/(800) 877-1295
General
Description
The Series LFII (1Y2234) Residential
Pendent Sprinklers are decorative,
fast response, frangible bulb sprinklers
designed for use in residential occu-
pancies such as homes, apartments,
dormitories, and hotels. When aesthet-
ics and optimized flow characteristics
are the major consideration, the Series
LFII (TY2234) should be the first
choice.
The Series LFII are to be used in wet
pipe residential sprinkler systems for
one- and two-family dwellings and mo-
bile homes per NFPA 13D; wet pipe
residential sprinkler systems for resi-
dential occupancies up to and includ-
ing four stories in height per NFPA
13R; or, wet pipe sprinkler systems for
the residential portions of any occu-
pancy per NFPA 13.
The Series LFII (TY2234) has a 4.9
(70,6) K-factor that provides the re-
quired residential flow rates at reduced
pressures, enabling smaller pipe sizes
and water supply requirements.
The recessed version of the Series
LFII (1Y2234) is intended for use in
areas with finished ceilings. It employs
a two-piece Style 20 Recessed Es-
cutcheon. The Recessed Escutcheon
provides 1/4 inch (6,4 mm) of recessed
adjustment or up to 1/2 inch (12,7 mm)
of total adjustment from the flush ceil-
ing position. The adjustment provided
by the Recessed Escutcheon reduces
the accuracy to which the pipe nipples
to the sprinklers must be cut.
The Series LFII (1Y2234) has been
designed with heat sensitivity and
water distribution characteristics
proven to help in the control of residen-
tial fires and to improve the chance for
occupants to escape or be evacuated.
WARNINGS
The Series LFII (TY2234) Residential
Pendent Sprinklers described herein
must be installed and maintained in
compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation, in addition to the standards of
any other authorities having jurisdic-
tion. Failure to do so may impair the
integrity of these devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
relative to any questions.
Sprinkler/Model
Identification
Number
SIN TY2234
Technical
Data
Approvals:
UL and C-UL Listed.
Maximum Working Pressure:
175 psi (12,1 bar)
Discharge Coefficient:
K = 4.9 GPM/p5i112 (70,6 LPMIbarl'2)
Temperature Rating:
155°F/68°C or 175°F/790C
Finishes:
White Polyester Coated,
Chrome Plated, or Natural Brass
Physical Characteristics:
Frame .............Brass
Button .............Bronze
Sealing Assembly . ..........
Beryllium Nickel w/leflont
Bulb .........3 mm dia. Glass
Compression Screw .....Bronze
Deflector ...........Bronze
Ejection Spring . . . Stainless Steel
tDuPont Registered Trademark
Operation
The glass Bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass Bulb allowing the sprinkler to
activate and flow water.
Page 1 of 8 JANUARY, 2003 TFP400
Page 2 of 8 TFP400
Minimum Flow (b) and Minimum Flow (b) and Minimum Flow (b) and
Maximum Maximum Residual Pressure Residual Pressure Residual Pressure
Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling
Area (a) Ft. (Max. 2 Inch Rise (Greater Than 2 inch Rise (Greater Than 4 inch Rise
Ft. x Ft. (m) for 12 inch Run) Up To Max. 4 inch Rise for 12 inch Run) Up To Max. 8 inch Rise for 12 inch Run)
(m x m) 155°F168C or 155FI68*C 175Fl79°C 155F/68C 175Fl79°C
175°F179°C
12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) (3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar)
14 x 14 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) (4,3 x 4,3) (4,3) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar)
16x 16 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM)
(4,9 x 4,9) (4,9) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar)
18 x 18 18 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 23 GPM (87,1 LPM) (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 22.0 psi (1,52 bar)
20 x 20 20 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 21 GPM (79,5 LPM) N/A (6,1 x 6,1) (6,1) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 18.4 psi (1,27 bar)
For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next
highest coverage area for which hydraulic design criteria are stated.
Requirement is based on minimum 110w in GPM (LPM) from each sprinkler. The associated residual pressures are calculated
using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.
TABLE A
NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2234)
RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS
Design
Criteria
The Series LFII (TV2234) Residential
Pendent Sprinklers are UL and C-UL
Listed for installation in accordance
with the following criteria.
NOTE
When conditions exist that are outside
the scope of the provided criteria, refer
to the Residential Sprinkler Design
Guide TFP490 for the manufacturer's
recommendations that maybe accept-
able to the localAuthority having Juris-
diction.
System Type. Only wet pipe systems
may be utilized.
Hydraulic Design. The minimum re-
quired sprinkler flow rate for systems
designed to NFPA 130 or NFPA 13R
are given in Table A as a function of
temperature rating and the maximum
allowable coverage areas. The sprin-
kler flow rate is the minimum required
discharge from each of the total
number of "design sprinklers" as speci-
fied in NFPA 130 or NFPA 13R.
For systems designed to NFPA 13, the
number of design sprinklers is to be
the four most hydraulically demanding
sprinklers. The minimum required dis-
charge from each of the four sprinklers
is to be the greater of the following:
The flow rates given in Table A for
NFPA 13D and 13R as a function of
temperature rating and the maxi-
mum allowable coverage area.
A minimum discharge of 0.1 gpm/sq.
ft. over the "design area" comprised
of the four most hydraulically de-
manding sprinklers for the actual
coverage areas being protected by
the four sprinklers.
Obstruction To Water Distribution.
Locations of sprinklers are to be in
accordance with the obstruction rules
of NFPA 13 for residential sprinklers.
Operational Sensitivity. The sprin-
klers are to be installed with a deflector
to ceiling distance of 1-3/8 to 4 inches
or in the recessed position using only
the Style 20 Recessed Escutcheon as
shown in Figure 2.
NOTE
So as to help avoid obstructions to
water distribution, a maximum 12 inch
deflector-to-ceiling distance is permit-
ted for NFPA 13D and NFPA 13Rap-
plications where the sprinklers are lo-
cated in closets.
Sprinkler Spacing. The minimum
spacing between sprinklers is 8 feet
(2,4 m). The maximum spacing be-
tween sprinklers cannot exceed the
length of the coverage area (Ref. Table
A) being hydraulically calculated (e.g.,
maximum 12 feet for a 12 ft. x 12 ft.
coverage area, or 20 feet for a 20 ft. x
20 ft. coverage area).
Beam Ceiling
Design Criteria
The Series LFII (1Y2234) Residential
Pendent Sprinklers are UL and C-UL
Listed for installation in residential oc-
cupancies with horizontal ceilings (i.e.,
slopes up to a 2 inch rise over a 12 inch
run) with beams when installed in ac-
cordance with the following criteria:
General Information. The basic con-
cept of this protection scheme is to
locate the sprinklers on the underside
of the beams, Ref. Figure 5, (not in the
beam pockets); to identify the main
beams that principally run in one direc-
tion as "primary beams"; and, to iden-
tify the beams that run principally per-
pendicular to the main beams, as may
be present (or in some cases may be
necessary for proper sprinkler protec-
tion), as "secondary beams".
Primary and Secondary Beam
Types. Solid surface, solid or hollow
core, combustible or non-combustible.
Primary and Secondary Beam Posi-
tioning. Directly attached to the un-
derside of a combustible or non-com-
bustible smooth ceiling at any
elevation.
Primary Beam Cross-Section: Maxi-
mum depth of 14 inches and the maxi-
mum width is unlimited. The cross-sec-
tional shape of the primary beam may
be rectangular to circular.
TFP400 Page 3 of 8
Components:
1 - Frame
2 - Button
Seating Assembly
Bulb
Compression
Screw
Deflector *
Ejection Spring
* Temperature
rating is
indicated on 6
Deflector.
7/16(11,1 mm) ,, ESCUTCHEON
NOMINAL NP T PLATE SEATING
MAKE-IN SURFACE
7
2-1/4 '
______ (57,2 mm)
-S....
1-5/8'
(41.3 mm) I
11
2-7/8 DIA.
(73.0 mm)
WRENCH STYLE 20
FLATS RECESSED
ESCUTCHEON
CROSS SECTION PENDENT RECESSED PENDENT
FIGURE 1
SERIES LFII (TY2234) RESIDENTIAL
PENDENT AND RECESSED PENDENT SPRINKLERS
- 2-7/8"DIA. -
7/16*1/8" (73.0 mm) I 1/2(12,7mm) r (11.1:t3,2 mm) 2-1/4DIA. I 1/4(6,4mm) I
FACE OF mm)
I SPRINKLER 157.2 MOUNTING I FITTING PLATE I
t MOUNTING 1/8 I SURFACE/
(3.2 mm) I
CLOSURE
/ - TY2234 1-3/8(34.9 mm) j
1-1/8 (28,6 mm)
FIGURE 2
STYLE 20 RECESSED ESCUTCHEON
FOR USE WITH THE SERIES LFII (TY2234)
RESIDENTIAL PENDENT SPRINKLER
Secondary Beam Cross-Section.
Maximum depth to be no greater than
the primary beam and the maximum
width is unlimited. The cross-sectional
shape of the secondary beam may be
rectangular to circular.
,~W(RENCH RECESS
ENDA USED
FOR 1Y2234)
FIGURE 3
W- TYPE 6
SPRINKLER WRENCH
WRENCH
RECESS
PUSH WRENCH
INTO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 4
W- TYPE 7 RECESSED
SPRINKLER WRENCH
the primary beam must be placed so
that the beam pockets created by the
primary beams do not exceed 20 feet
in length (Fig. 6B).
NOTE
Primary Beam Spacing. The primary
beams (Fig. 6A) are to be 3 ft. -4 in. to
6 ft. from the compartment wall to cen-
ter of the nearest beam and from cen-
ter to center between beams.
Secondary Beam Spacing. The sec-
ondary beams principally run perpen-
dicular to the primary beams.
Secondary beams of a depth equal to
When the beam pockets created by
the primary beams exceed 20 feet in
length, the installation will require the
use of secondary beams as described
above. Otherwise, secondary beams
need not be present.
Secondary beams of a cross-sectional
depth greater than one-quarter the
depth of the primary beams are to be
a minimum of 3 ft. - 4 in. from the
compartment wall to center of the
nearest beam and from center to Cen-
ter between beams (Fig. 6C).
Secondary beams of a cross-sectional
depth no greater than one-quarter the
depth of the primary beams may be
placed at any compartment wall to
center of the nearest beam distance
Page 4 of 8 TFP400
and from any center to center distance
between beams (Fig. 6C).
Lintels. Lintels over doorways exiting
the compartment must be present. The
minimum height for the lintels is 8
inches or no less than the depth of the
Primary Beams, whichever is greater.
Sprinkler Types. Series LFll
(TY2234), 155F and 175F, Pendent
and Recessed Pendent Residential
Sprinklers.
Sprinkler Coverage Area and Hy-
draulic Design. The sprinkler cover-
age areas and hydraulic design criteria
as presented in the Table A for Hori-
zontal Ceilings" are to be applied.
Sprinkler Position. The deflector to
bottom of primary beams for the Series
LFll (1Y2234) Pendent Sprinklers or
Series LFII (TY2234) Recessed Pen-
dent Sprinklers is to be 1-1/4 to 1-3/4
inches (Fig. 5A). The vertical center-
line of the Series LFll (TY2234) Pen-
dent Sprinklers is to be no greater than
half the primary beam cross-sectional
width plus 2 inches from the centerline
of the primary beam (Fig 5B).
NOTES
Core drilling of beams to allow the in-
stallation of sprinkler drops requires
consulting with a structural engineer.
Where core drilling is not permitted,
the previously stated sprinkler position
criteria for the Series LFll (TY2234)
Pendant Sprinklers allows for the
sprinkler drop to be placed adjacent to
the primary beam.
Beam and Soffit Arrangements. A
soffit is permitted to be placed around
the perimeter of a compartment with
the beam arrangement within the sot-
filed area (Fig.7).
The cross-section of the soft it may be
any size as long as it does not create
an obstruction to water distribution per
the obstruction rules of NFPA 13 for
residential sprinklers.
When soffits are present, the pre-
viously provided 3 ft. - 4 in. to 6 ft.
"compartment wall to adjacent beam"
distance for the primary and secon-
dary beams is to be measured from the
face of the soffit as opposed to the
compartment wall.
NOTE
Although the distance to the beams is
measured from the face of the soffit,
the sprinkler coverage area is to be
measured from the compartment wall.
Installation
The Series LFII (TY2234) must be in-
stalled in accordance with the follow-
ing instructions:
NOTES
Do not install any bulb type Sprinkler if
the bulb is cracked or there is a loss of
liquid from the bulb. With the sprinkler
held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6mm).
A leak tight 1/2 inch NPT sprinklerjoint
should be obtained with a torque of 7
to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi-
mum of 21 ft.lbs. (28,5 Nm) of torque
is to be used to install sprinklers.
Higher levels of torque may distort the
sprinkler inlet with consequent leak-
age or impairment of the sprinkler.
Do not attempt to compensate for in-
sufficient adjustment in an Escutcheon
Plate by under- or over-tightening the
Sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series LFll Pendent Sprinklers
must be installed in accordance with
the following instructions.
Step 1. Pendent sprinklers are to be
installed in the pendent position with
the deflector parallel to the ceiling.
Step 2. With pipe thread sealant ap-
plied to the pipe threads, hand tighten
the sprinkler into the sprinkler fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 3).
With reference to Figure 1, the W-Type
6 Sprinkler Wrench is to be applied to
the wrench flats.
The Series LFII Recessed Pendent
Sprinklers must be installed in ac-
cordance with the following instruc-
tions.
Step A. Recessed pendent sprinklers
are to be installed in the pendent posi-
tion with the deflector parallel to the
ceiling.
Step B. After installing the Style 20
Mounting Plate over the sprinkler
threads and with pipe thread sealant
applied to the pipe threads, hand
tighten the sprinkler into the sprinkler
fitting.
Step C. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 4). With reference to Figure 1,
the W-Type 7 Recessed Sprinkler
Wrench is to be applied to the sprinkler
wrench flats.
Step D. After the ceiling has been in-
stalled or the finish coat has been ap-
TY2234
B
MAXIMUM TY2234 ONE-HALF BEAM
WIDTH PLUS
2" (50.8 mm)
FIGURE 5
SPRINKLER POSITIONING
UNDER PRIMARY BEAMS
(Refer to the "Beam Ceiling
Design Criteria" section)
plied, slide on the Style 20 Closure
over the Series LFII Sprinkler and
push the Closure over the Mounting
Plate until its flange comes in contact
with the ceiling.
PRIMP
BEAI
COMPARTMENT
WALLS
PRIMP
BEAI
* REFER TO
FIGURE 6B COMPARTMENT
FOR SPANS WALLS
EXCEEDING
20'-0'(6.1 m)
TFP400
ALLFIGURES:
DISTANCES ARE
MEASURED TO
COMPARTMENT
WALL FACES AND
TO CENTERLINES
OF BEAMS
ra
NIA
PRIMARY
BEAM
COMPARTMENT
WALLS
A_H A—.I
Page 5 of 8
14'(356 mm)
MAXIMUM
A= 3.4' to 6-0" (1.0 to 1.8 m)
FOR PRIMARY BEAMS HAV-
ING A 14" (356 mm) MAXIMUM
DEPTH
20'-0"(6.1 m)
MAXIMUM
FIGURE 6k
PRIMARY BEAM SPANS UP TO 20-0" (6.1 m)
A A_
•.. A_—_I
IF
FOR PRIMARY BEAMS HAV.
BEAM DEPTH
FIGURE 6B
PRIMARY BEAM SPANS GREATER THAN 2&-0"(6.1 m)
B = 20'-0'(6.1 m) MAXIMUM
FOR SECONDARY BEAMS
THAT ARE TO BE EQUAL IN
DEPTH TO PRIMARY BEAMS
AND THAT MUST BE IN PLACE
SO THAT PRIMARY BEAM
POCKETS DO NOT EXCEED
20'-0"(6.1 m)
h_A -j- A -i"._A—_I
1 C
SECONDAR4J ____ 1C
. FOR PRIMARY BEAMS HAV-
DEPTH
GA1456mm)MAMUM
BEAM
SECONDARY BEAMS HAVING
DEPTHS GREATER THAN 2596
OF PRIMARY BEAMS
—or—
C = ANY DISTANCE FOR SEC.
ONDARY BEAMS HAVING
DEPTHS UP TO 25% OF
PRIMARY BEAMS
FIGURE 6C
COMBINATIONS OF PRIMARY AND SECONDARY BEAMS
FIGURE 6
BEAM ARRANGEMENTS
(Refer to the "Beam Ceiling Design Criteria" section)
Page 6 of 8 TFP400
SECONDARY
BEAM
P IM
* USE DISTANCES SHOWN R ARY IN FIGURES 6A. 6B & 6C. BEAM EXCEPT MEASUREMENTS
ARE TAKEN FROM FACES
OF SOFFITS INSTEAD OF
FROM COMPARTMENT
WALL SURFACES FACE OF -
SOFFIT
COMPARTMENT
WALLS 7-7277,7
FIGURE 7
BEAM AND SOFFIT ARRANGEMENTS
(Refer to the "Beam Ceiling Design Criteria" section)
Care and
Maintenance
The Series LFIl (TY2234) must be
maintained and serviced in accord-
ance with the following instructions:
NOTES
Absence of an Escutcheon Plate may
delay the sprinkler operation in a fire
situation.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
which it controls, permission to shut
down the affected fire protection sys-
tem must be obtained from the proper
authorities and all personnel who may
be affected by this action must be no-
tified.
Sprinklers which are found to be leak-
ing or exhibiting visible signs of corro-
sion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a Cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler that
has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturer should be contacted relative to
any questions.
NOTE
The owner must assure that the sprin-
klers are not used for hanging of any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster; otherwise, non-
operation in the event of a fire or inad-
vertent operation may result.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service.
TFP400 Page 7 of 8
Limited
Warranty
Products manufactured by Tyco Fire
Products are warranted solely to the
original Buyer for ten (10) years
against defects in material and work-
manship when paid for and properly
installed and maintained under normal
use and service. This warranty will ex-
pire ten (10) years from date of ship-
ment by Tyco Fire Products. No war-
ranty is given for products or
components manufactured by compa-
nies not affiliated by ownership with
Tyco Fire Products or for products and
components which have been subject
to misuse, improper installation, corro-
sion, or which have not been installed,
maintained, modified or repaired in ac-
cordance with applicable Standards of
the National Fire Protection Associa-
tion, and/or the standards of any other
Authorities Having Jurisdiction. Mate-
rials found by Tyco Fire Products to be
defective shall be either repaired or
replaced, at Tyco Fire Products' sole
option. Tyco Fire Products neither as-
sumes, nor authorizes any person to
assume for it, any other obligation in
connection with the sale of products or
parts of products. Tyco Fire Products
shall not be responsible for sprinkler
system design errors or inaccurate or
incomplete information supplied by
Buyer or Buyer's representatives.
IN NO EVENT SHALL TYCO FIRE
PRODUCTS BE LIABLE, IN CON-
TRACT, TORT, STRICT LIABILITY OR
UNDER ANY OTHER LEGAL THE-
ORY, FOR INCIDENTAL, INDIRECT,
SPECIAL OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT
LIMITED TO LABOR CHARGES, RE-
GARDLESS OF WHETHER TYCO
FIRE PRODUCTS WAS INFORMED
ABOUT THE POSSIBILITY OF SUCH
DAMAGES, AND IN NO EVENT
SHALL TYCO FIRE PRODUCTS' LI-
ABILITY EXCEED AN AMOUNT
EQUAL TO THE SALES PRICE.
Ordering
Procedure
When placing an order, indicate the full
product name. Contact youi local dis-
tributor for availability..
Sprinkler Assembly:
Series LFII (1Y2234), K=4.9, Residen-
tial Pendent Sprinkler with (specify)
temperature rating and (specify) finish,
P/N (specify).
155'F/68°C or Chrome Plated .........P/N 51-201-9-155 155°F/68'C White Polyester ........P/N 51-201.4-155 155°F/68'C Natural Brass ..........P/N 51-201.1-155 175'F/79"C or Chrome Plated .........P/N 51-2019-175 175'F179°C
White Polyester ........PIN 51-201.4-175 175°F179'C
Natural Brass ..........P/N 51-201.1.175
Recessed Escutcheon:
Specify: Style 20 Recessed Escutch-
eon with (specify) finish, P/N (specify).
1/2' (15 mm) Style 20
Chrome Plated .........P/N 56-705.9.010
1/2" (15 mm)
Style 20
White Color Coated ...............P/N 56-705.4-010
1/2 (15 mm) Style 20
Bright Brass
Coated ...............P/N 56-705-2-010
Sprinkler Wrench:
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387.
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001.
Page 8 of 8 TFP400
TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446
tqCO Fire & Building
liProducts
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
A
Customer Service/Sales:
Tel: (414) 570-5000 / (800) 558-5236
Fax: (414) 570-5010/(800) 877-1295
Series TYIFRB - 2.89 42,5.6, and 80 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General
Description
The Series TY-FAB, 2.8, 4.2, 5.6, and
8.0 K-factor, Upright and Pendent
Sprinklers described in this data sheet
are quick response - standard cover-
age, decorative 3 mm glass bulb type
spray sprinklers designed for use in
light or ordinary hazard, commercial
occupancies such as banks, hotels,
shopping malls, etc.
The recessed version of the Series
TY-FRB Pendent Sprinkler, where ap-
plicable, is intended for use in areas
with a finished ceiling. It uses either a
two-piece Style 10 (1/2 inch NPT) or
Style 40 (3/4 inch NPT) Recessed Es-
cutcheon with 1/2 inch (12,7 mm) of
recessed adjustment or up to 3/4 inch
(19,1 mm) of total adjustment from the
flush pendent position, or a two-piece
Style 20(1/2 inch NPT) or Style 30 (3/4
inch NPT) Recessed Escutcheon with
1/4 inch (6,4 mm) of recessed adjust-
ment or up to 1/2 inch (12,7 mm) of
total adjustment from the flush pen-
dent position. The adjustment provided
by the Recessed Escutcheon reduces
the accuracy to which the fixed pipe
drops to the sprinklers must be cut.
Corrosion resistant coatings, where
applicable, are utilized to extend the
life of copper alloy sprinklers beyond
that which would otherwise be ob-
tained when exposed to corrosive at-
mospheres. Although corrosion resis-
tant coated sprinklers have passed the
standard corrosion tests of the appli-
cable approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently, it
is recommended that the end user be
consulted with respect to the suitability
of these coatings for any given corro-
sive environment. The effects of ambi-
ent temperature, concentration of
chemicals, and gas/chemical velocity,
should be considered, as a minimum,
along with the corrosive nature of the
chemical to which the sprinklers will be
exposed.
An intermediate level versions of the
Series TY-FRB Pendent Sprinklers are
detailed in Technical Data Sheet
TFP356, and Sprinkler Guards are de-
tailed in Technical Data Sheet TFP780
WARNINGS
The Series TY-FRB Sprinklers de-
scribed herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the integrity of these devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
relative to any questions.
Model/Sprinkler
Identification
Numbers
TY1131 - Upright 2.81K, 1/2'NPT
TY1231 - Pendent 2.81K, 1/2'NPT
TY2131 - Upright 4.21K, 112'NPT
TY2231 - Pendent 4.21K, 112'NPT
TY3131 - Upright 5.61K, 1/2'NPT
TY3231 - Pendent 5.61K, 1/2"NPT
TY4131 - Upright 8.01K, 3/4"NPT
1Y4231 - Pendent 8.01K, 3/4'NPT
Technical
Data
Approvals
UL and C-UL Listed.
FM, LPCB, and NYC Approved.
(Refer to Table A for complete approval
information including corrosion resis-
tant status.)
-
,
r
r\ A
Maximum Working Pressure
175 psi (12,1 bar)
Discharge Coefficient
K = 2.8 GPM/psil'2 (40,3 LPM/bar112)
K = 4.2 GPM/psi l/2 (60,5 LPM/barl'2)
K = 5.6 GPM/p5i112 (80,6 LPM/bar112)
K = 8.0 GPM/psill2 (115,2 LPM/bar1/2)
Temperature Ratings
Refer to Table A and B
Finishes
Sprinkler: Refer to Table A and B
Recessed Escutcheon: White Coated,
Chrome Plated, or Brass Plated
Physical Characteristics
Frame ............Bronze
Button ........Brass/Copper
Sealing Assembly ..........
Beryllium Nickel w/Teflonf
Bulb ..............Glass
Compression Screw .....Bronze
Deflector .......Copper/Bronze
Bushing (K=2.8) .......Bronze
I-
Page 1 of 8 APRIL, 2003 TFPI7I
ESCUTCHEON
PLATE SEATING
SURFACE
7/16(11,1 mm)
1/2" ** NOMINAL.
.Ini - MAKE-IN -
STYLE 10or20
RECESSED
ESCUTCHEON
L
FLATS
WRENCH
2-7/8° (73,0 mm) DIA.
RECESSED PENDENT
SSP DEFLECTOR *
PENDENT
7/16"(11,1 mm)
NOMINAL
MAKE-IN 1/2° **
NPT
Page 2 of 8 TFPI7I
SSU* I
DEFLECTOR I
SI
1T1i'
7/16°
(11,1 mm) I II III NOMINAL I
I MAKE-IN
2-3/16° "
556mm)
I 7'
1/2' NPT**
UPRIGHT CROSS SECTION
1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame.
Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 1
QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY1I31) AND PENDENT (TY1231) SPRINKLERS
2.8 K-FACTOR, 1/2 INCH NPT
ESCUTCHEON
PLATE SEATING
SURFACE
T_
2-3/16° \—
(55,6 mm)
(38,1 mm)
STYLE 100r20
RECESSED SSU*
ESCUTCHEON DEFLECTOR
/ 7/16° /
IT
(11,1 mm) I NOMINAL
AAI# lid
I 2-3/16°
WRENCH (55,6 mm)
FLATS
-W
2-7 /8° (73,0 mm) DIA. 1/2" NPT** I SSP DEFLECTOR*
PENDENT
11
RECESSED PENDENT UPRIGHT CROSS SECTION
1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 2
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV2131) AND PENDENT(TY2231) SPRINKLERS
4.2 K-FACTOR, 1/2 INCH NPT
6*
TFPI7I Page 3 of 8
ESCUTCHEON
PLATE SEATING
SURFACE
T_
23/1& 6
MM)
(55,6 mm)
1
(38,
7/16 (11,1 mm)
1/2 ** NOMINAL
MAKE-IN NPT
STYLE 10or20
RECESSED SSU* ESCUTCHEON DEFLECTOR
I
7/16 iIk11'1i\ (11,1 mm) 1 Ill II NOMINAL
MAKE-IN
AL I
1iJWREN1H
2-3/16
-.1
(55,6mm
FLATS
)
1/2ONPT** t SSP DEFLECTOR* I---- 2-7/8 (73,0 mm) DIA.
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
1 - Frme 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 3
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT(TY3231) SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT
ESCUTCHEON 1/2 (12,7 mm)
PLATE SEATING 3/4" ** NOMINAL
SURFACE MAKE-IN
2-5/
T_
16
_
NPT
(58,7 mm)
1-9/16" I (39,7 mm)
______
SSPDEFLECTOR* L 2 ...
PENDENT REC
STYLE 30 or 40
RECESSED SSU*
ESCUTCHEON DEFLECTOR
6*
1/2k I 5
(12,7 mm) I
NOMINAL
MAKE-IN
I 2-1/4"
(57,2 mm)
3
3/4 NPT I
UPRIGHT CROSS SECTION
WRENCH
FLATS
-7/8' (73,0 mm) DIA.
ESSED PENDENT
1 - Frame 3- Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 4
QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS
8.0 K-FACTOR, 3/4 INCH NPT
Operation
The glass Bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass Bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The Series TY-FRB Pendent and Up-
right Sprinklers are intended for fire
protection systems designed in ac-
cordance with the standard installation
rules recognized by the applicable
Listing or Approval agency (e.g., UL
Listing is based on the requirements of
NFPA 13, and FM Approval is based
on the requirements of FM's Loss Pre-
vention Data Sheets ). Only the Style
10, 20, 30, or 40 Recessed Escutch-
eon, as applicable, is to be used for
recessed pendent installations.
I It
Page 4 of 8 TFPI7I
SPRINKLER FINISH (See Note 7)
K TYPE TEMP. BULB
LIQUID
NATURAL
BRASS
I CHROME
PLATED
I WHITE"
IPOLVESTER
2.8
1/2°
PENDENT
(TY1231)
and
UPRIGHT
(TY1131)
135°F/57°C Orange
12,3,5
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
286°F/141°C Blue
NPT RECESSED
PENDENT
(TY2231)°
Figure 5
135°F/57°C Orange
1, 2,5
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
RECESSED
PENDENT
(TY2231)"
Figure 6
135°F/57°C Orange
155°F168°C Red
175°F/79°C Yellow
200°F/93°C Green
4.2
1/20
NPT
PENDENT
(TY2231)
and
UPRIGHT
(TY3131)
135°F/57°C Orange
1,2
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
286°F/141'C Blue
135°F/57°C Orange
RECESSED
PENDENT
(TY2231)
Figure 7
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
RECESSED
PENDENT
(TY2231)'°
Figure 8
1350F/57°C Orange
155°F/68°C Red
175°F179°C Yellow
200°F/93°C Green
NOTES:
Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response
Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin-
klers.
5. Approved by the City of New York under MEA 354-01-E.
7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin-
klers are UL and C-UL Listed as Corrosion Resistant Sprinklers.
Installed with Style 10 (1/2 NPT) or Style 40 (3/40 NPT) 3/4° Total Adjustment Re-
cessed Escutcheon, as applicable.
Installed with Style 20 (1/2° NPT) or Style 30 (3/4° NPT) 1/2° Total Adjustment Re-
cessed Escutcheon, as applicable.
Frame and Deflector only. Listings and approvals apply to all colors (Special Order).
N/A: Not Available
TABLE A
LABORATORY LISTINGS AND APPROVALS
2.8 AND 4.2 K-FACTOR SPRINKLERS
Installation
The Series TY-FRB Sprinklers must be
installed in accordance with the follow-
ing instructions:
NOTES
Do not install any bulb type sprinkler if
the bulb is cracked or there is loss of
liquid from the bulb. With the sprinkler
held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F/570C to 3/32
inch (2,4 mm) for the 286°F/1410C
temperature ratings.
A leak tight 1/2 inch NPTsprinkler joint
should be obtained with a torque of 7
to 14 Albs. (9,5 to 19,0 Nm). A maxi-
mum of 21 ft. lbs. (28,5 Nm) of torque
may be used to install sprinklers with
1/2 NPT connections. A leak tight 3/4
inch NPT sprinkler joint should be ob-
tained with a torque of 10 to 20 Albs.
(13,4 to 26,8 Nm). A maximum of 30
ft.!bs. (40,7 Nm) of torque is to be used
to install sprinklers with 3/4 NPT con-
nections. Higher levels of torque may
distort the sprinkler inlet and cause
leakage or impairment of the sprinkler.
Do not attempt to make-up for insuffi-
cient adjustment in the escutcheon
plate by under- or over-tightening the
sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series TY-FRB Pendent and Up-
right Sprinklers must be installed in
accordance with the following instruc-
tions.
Step 1. Pendent sprinklers are to be
installed in the pendent position, and
upright sprinklers are to be installed in
the upright position.
Step 2. With pipe thread sealant ap-
plied to the pipe threads, hand tighten
the sprinkler into the sprinkler fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 13).
With reference to Figures 1, 2, 3, and
4, the W-Type 6 Sprinkler Wrench is to
be applied to the sprinkler wrench
flats.
The Series TY-FRB Recessed Pen-
dent Sprinklers must be installed in
accordance with the following instruc-
tions.
Step A. After installing the Style 10.
20, 30, or 40 Mounting Plate, as appli-
cable, over the sprinkler threads and
with pipe thread sealant applied to the
pipe threads, hand tighten the sprin-
kler into the sprinkler fitting.
Step B. Tighten the sprinkler into the
TFPI7I Page 5 of 8
SPRINKLER FINISH (See Note 7)
K TYPE TEMP. BULB
LIQUID
NATURAL
BRASS
I CHROME
PLATED
I WHITE-
IPOLYESTER
LEAD
COATED
5.6
PENDENT
(TY3231)
and
UPRIGHT
(TY3131)
135°F/57°C Orange
1. 2,3.4.5,6 1,23,5
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
286°F/141°C Blue
1/2°
NPT RECESSED
PENDENT
(TY3231)°
Figure 9
135°F/57°C Orange
1,2.4.5 N/A 155F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
RECESSED
PENDENT
(TY3231)0*
Figure 10
135°F/57°C Orange
1, 2, 3,4,5
I I I I 1, 2,4, 5
I
Green
N/A
155°F/68°C Red
1750F/79°C Yellow
200°F/93°C
8.0
3/4.
PENDENT
(TY4231)
and
UPRIGHT
(TY4131)
135°F/57°C Orange
1,2,3,4,5,6'
1,2,5
155°F/68°C Red
175°F/79°C Yellow
200°F/93°C Green
286°F/141°C Blue
NPT RECESSED
PENDENT
(TY4231)°
Figure 11
135°F/57°C Green
1,2,4,5 N/A
155F/68°C Orange
175°F/79°C Red
200°F/93°C Yellow
RECESSED
PENDENT
(1Y4231)"
Figure 12
135°F/57°C Orange
1,2,3,4,5 N/A
155°F/66°C Red
175°F/79°C Yellow
200°F/93°C Green
NOTES:
Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the Loss Prevention Certification Board (LPCB) as Quick Response Sprinklers; however, the LPC does not rate the thermal
sensitivity of recessed sprinklers.
Approved by the City 01 New York under MEA 354-01-E.
VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377).
Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C.UL Listed as
Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a
Corrosion Resistant Sprinklers.
Installed with Style 10 (1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20 (1/2° NPT) or Style 30 (3/4' NPT) 1/2° Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only. Listings and approvals apply to all colors (Special Order).
N/A: Not Available
TABLE B
LABORATORY LISTINGS AND APPROVALS
5.6 AND 8.0 K-FACTOR SPRINKLERS
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 14). With reference to Figure 1,
2, 3, and 4, the W-Type 7 Recessed
Sprinkler Wrench is to be applied to
the sprinkler wrench flats.
Step C. After the ceiling has been in-
stalled orthe finish coat has been ap-
plied, slide on the Style 10, 20, 30, or
40 Closure over the Series TY-FRB
Sprinkler and push the Closure over
the Mounting Plate until its flange
comes in contact with the ceiling.
Page 6 of 8
- 2-7/8" DIA. -
518±1/4"
(73.0 mm) I 3/4"(19.1 mm)
(15.9±6.4 mm) - 2-1/4" DIA. I 1/4" (6.4 mm) I
I
FACE OF %_57.2 mm) MOUNTING
SPRINKLER PLATE
I
FITTING
1/8"
MOUNTING /
SURFACE
1-5/16" (33 CLOSURE SERIES (33.3 mm)
TY-FRB 13/16"(20.6 mm)
FIGURE 5
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT
2-7/8" DIA. -
5/8±1/4"
(73.0 mm) I 3/4"(19.1 mm)
(15.9±6.4 mm) 2-1/4" DIA. I 1/4"(6.4 mm) I
I MOU I FACE OF NTING
SPRINKLER I PLATE I
FITTING
1/8"
j
\
MOUNTING/
.T SURFACE
CLOSURE SERIES 1-1/4"(318 mm)
TYFRB 3/4" (19.1 mm)
FIGURE 7
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT
TFPI7I
- 2-7/8" DIA.
(73.0 mm) 1/2±1/8" 1/2" (12.7 mm) r (12.7±3.2 mm) 2-1/4" DIA. I 1/4'(6,4 mm) I
I SPRINKLER lei j....- PLATE
FACE OF
F57-2
mm) MOUNTING
FITTING
1/8" I __
MOUNTING
M(3.2 mm)
SURFACE
CLOSURE SE 1-5/16"(33.3 mm)
TY-FRB 11/16" (27.0 mm)
FIGURE 6
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT
2-7/8" DIA. -
1/2±1/8" I (73.0 mm) 1/2"(12.7 mm)
1 (12.7±3.2 mm) 2-1/4" DIA. I 1/4" (6.4 mm) I I FACE OFq
R
(572 mm) MOUNTING I
1/8"
SPRINKLE
F,j
PLATEFITTING
(3.2mm)
MOUNTIN
SURFACE
CLOSURE SERIES 1-1/4"(31.8 mm)
TY-FRB 1" (25.4 mm)
FIGURE 8
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT
Care and
Maintenance
The Series TY-FRB Sprinklers must be
maintained and serviced in accord-
ance with the following instructions:
NOTES
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shutdown the
affected fire protection system must be
obtained from the proper authorities
and all personnel who may be affected
by this action must be notified.
Absence of an escutcheon, which is
used to cover a clearance hole, may
delay the time to sprinkler operation in
a fire situation.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
Automatic sprinklers must never be
painted, plated, coated or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler that
has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
Frequent visual inspections are rec-
ommended to be initially performed for
corrosion resistant coated sprinklers,
after the installation has been com-
pleted, to verify the integrity of the cor-
rosion resistant coating. Thereafter,
annual inspections per NFPA 25
should suffice; however, instead of in-
specting from the floor level, a random
sampling of close-up visual inspec-
tions should be made, so as to better
determine the exact sprinkler condi-
TFPI7I
- 2-7/8" DIA. -
5/8±1/4"
(73.0 mm) 314"(19.1 mm)
(15.9±6.4 mm) 2-1/4" DIA. 1/4" (6.4 mm) I
FACE OF MOUNTING SPRINKLER PLATE
FITTING
1/8"
(3.2 mm)
UL'
MOUNTING,,//"
SURFACE
SERIES 1.1/4'(31.8mm) CLOSURE TYFRB 3/4'(19.1 mm)
FIGURE 9
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
- 2-7/8" DIA.
5/8±1/4" (73.0 mm) - I 3/4' (19.1 mm)
(15.9±6.4 mm) 2-1/4" DIA. I 1/4" (6.4 mm) I
I (57.2 MOUNTING FACE OF I PLATE SPRINKLER
FITTING 1/8" I _____________ I
MOUNTING
/1'..••'
_
SURFACE
CLOSURE SERIES 1-5/16" (33.3 mm)
TYFRB 13/16'(20,6 mm)
FIGURE 11
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
Page 7 of 8
- 2-7/8" DIA. -
(73.0 mm) 1/2±1/8" 1/2"(12,7 mm) r (12.7±32 mm) 2.1/4" DIA. 1/4" (6,4 mm) I
I SPRINKLEqR PLATE
FACE OF 572 mm) MOUNTING
I FITTING
/ 1/8"
32mm)
t MOUNTIN
SURFACESERIES
1-1/4" (31.8 mm) CLOSURE TYFRB 1"(25.4 mm)
FIGURE 10
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
- 2-7/8' DIA.
1/2±1/8' (73.0 mm) 1/2"(12.7 mm)
r (12.7±32 mm) 2-1/4" DIA. 1/4"(6.4 mm)
FACE OF (57.2 mm) MOUNTING I
PLATE I FITTING 1/8" I (3.2 mm)
I SPRINKLER
t \
MOUNTING
SURFACE/
CLOSURE SERIES 1-5/16" (33.3 mm)I
TYFRB 1.1/16" (27.0 mm)
FIGURE 12
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
tion and the long term integrity of the
corrosion resistant coating, as it may
be affected by the corrosive conditions
present.
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturer should be contacted relative to
any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service.
WRENCH RECESS
(END 'A" USED FOR
1/2" NPT MODELS)
WRENCH RECESS
(END "B" USED FOR
3/4' NPT MODELS)
FIGURE 13
W- TYPE 6 SPRINKLER
WRENCH
WRENCH
RECESS
PUSH WRENCH
INTO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 14
W-TYPE 7 RECESSED
SPRINKLER WRENCH
Page 8 of 8 TFPI7I
P/N 57-XXX-X-XXX
I L
MODEUSIN
330 2.8K UPRIGHT (1/2'NPT) TY1131
331 2.8K PENDENT (1/2'NPT) TY1231
340 4.2K UPRIGHT (1/2'NPT) . TY2131
341 4.2K PENDENT (1/2'NPT) TY2231
370 5.6K UPRIGHT (1/2'NPT) TY3131
371 5.6K PENDENT (1/2'NPT) TY3231.
390 8.0K UPRIGHT (3/4'NPT) 1Y4131
391 8.0K PENDENT (3I4"NPT) 1Y4231
I I
I SPRINKLER
L 135
1 NATURAL BRASS
4 WHITE POLYESTER
9 CHROME PLATED
7 LEAD COATED
I
155
175
200
286
TEMPERATUF
RATING
155°F168°C
175'F179'C
200°F/93°C
286'F/141°C
TABLE C
PART NUMBER SELECTION
SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS
Limited
Warranty
Products manufactured by Tyco Fire
Products are warranted solely to the
original Buyer for ten (10) years
against defects in material and work-
manship when paid for and properly
installed and maintained under normal
use and service. This warranty will ex-
pire ten (10) years from date of ship-
ment by Tyco Fire Products. No war-
ranty is given for products or
components manufactured by compa-
nies not affiliated by ownership with
Tyco Fire Products or for products and
components which have been subject
to misuse, improper installation, corro-
sion, or which have not been installed,
maintained, modified or repaired in ac-
cordance with applicable Standards of
the National Fire Protection Associa-
tion, and/or the standards of any other
Authorities Having Jurisdiction. Mate-
rials found by Tyco Fire Products to be
defective shall be either repaired or
replaced, at Tyco Fire Products' sole
option. Tyco Fire Products neither as-
sumes, nor authorizes any person to
assume for it, any other obligation in
connection with the sale of products or
parts of products. Tyco Fire Products
shall not be responsible for sprinkler
system design errors or inaccurate or
incomplete information supplied by
Buyer or Buyer's representatives.
IN NO EVENT SHALL TYCO FIRE
PRODUCTS BE LIABLE, IN CON-
TRACT, TORT, STRICT LIABILITY OR
UNDER ANY OTHER LEGAL THE-
ORY, FOR INCIDENTAL, INDIRECT,
SPECIAL OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT
LIMITED TO LABOR CHARGES, RE-
GARDLESS OF WHETHER TYCO
FIRE PRODUCTS WAS INFORMED
ABOUT THE POSSIBILITY OF SUCH
DAMAGES, AND IN NO EVENT
SHALL TYCO FIRE PRODUCTS' LI-
ABILITY EXCEED AN AMOUNT
EQUAL TO THE SALES PRICE.
THE FOREGOING WARRANTY IS
MADE IN LIEU OF ANY AND ALL
OTHER WARRANTIES EXPRESS OR
IMPLIED. INCLUDING WARRANTiES
OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PUR-
POSE.
Ordering
Procedure
When placing an order, indicate the full
product name. Refer to the Price List
for complete listing of Part Numbers.
Contact your local distributor for avail-
ability.
Sprinkler Assemblies with NPT
Thread Connections:
Specify: (Specify Model/SIN), Quick
Response, (specify K-factor), (specify
temperature rating), Series TY-FRB
(specify Pendent or Upright) Sprinkler
with (specify type of finish or coating),
P/N (specify from Table C).
Recessed Escutcheon:
Specify: Style (specify) Recessed Es-
cutcheon with (specify finish), P/N
(specify).
1/2' (15 mm)
Style 10
Chrome Plated .........P/N 56.701.9.010
1/2' (15 mm) Style 10
White color
Coated ................P/N 56-701-4.010
1/2' (15 mm)
Style 10
Brass Plated ...........P/N 56.701.2-010
1/2' (15 mm)
Style 20
Chrome Plated ..........P/N 56-705.9.010
1/2 (15 mm)
Style 20
White color
Coated ................P/N 56-705-4-010
1/2' (15 mm)
Style 20
Brass Plated ...........P/N 56-705-2-010
314' (20 mm)
Style 30
Chrome Plated .........P/N 56-705-9-011
3/4 (20 mm) Style 30
White color
Coated ................P/N 56-705-4-011 314' (20 mm)
Style 30
Brass Plated ...........P/N 56-705.2-011
3/4' (20 mm)
Style 40
Chrome Plated .........P/N 56.700-9.010
3/4' (20 mm)
Style 40
White Color
Coated ................P/N 56-700-4.010
3/4' (20 mm)
Style 40
Brass Plated ...........P/N 56-700.2-010
Sprinkler Wrench:
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387.
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001.
TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446
-
.
tqcoiF;ow 1 Tyco Fire
I Control I Products
FIRE SPRINKLER Pii & FITTINGS SuIMITTAL SHEET
Tico FIRE PRODUCTS
451 North Cannon Avenue *
Lansdale, Pennsylvania 19446.
wwwtyco-firq.com
lkmlcu Smwvzs
Tw (800) 381-9312' FAx (800) 7914500
E.nuj techsen@tycofp.com
...No.19-1.3. :
• . 'Tb9i5 4-1.1.20
9/2001
9
90° Elbow
TOO Fittings
Reducing 450 Elbow
900 Elbow
Tee Cross Reducing
Cross
;co$itePrducts (TFP) BlazeMaster CPVC pipe and arney pr&ft $e4 heat resistance and
fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping
automatic fire sprinkler systems. They are made from a materials used in the plumbing trade. Various adapters are
specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping. All female
post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability.
the art additives. TFP BlazeMaster' CPVC products are Grooved adapters connect directly to grooved end valves
easier to install than traditional steel pipe systems, and at and metallic pipe, with flexible grooved end couplings.
Technical Data
Sizes: /' -3' Manufacture Source: U.S.A.
Maximum Working Pressure: 175 psi Material:
Approvals: UL, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5
MEA, and the City of Los Angeles Fittings: ASTM F436 (Sch. 40) and
Notm See arnentlFP BiazeMeeter Installation Instrudions and ASTM F439 (Sch. 80)
Technical Manual, for exact ltir(app,,al information Color: Orange
Pine
Nom.Pipe Size Avg. O.D. Inches Avg. I.D. Inches Wt. Lbs./Ft. Wt. $0 filled Pipe ft)Ft. Ft. of Pipe per Lift Wt. per Lift Lbs.
3/4 1.050 0.874 0.17 0.43 7875 1413
1.315 1.101 0.26 0.67 5040 1320
11/41'1.660 1.394 0.42 1.07 2835 1191
11/2"1.900 1.598 0.55 1.40 2205 1136
21375 2.003 0.86 2.20 1 1260 106
2'/2" 2.875 2.423 1.26 3.22 1215 1531
3.500 2.952 1.87 4.79 720 1 1344
Part No. Size Sch. T/O Wt.
80050 3/4" 40 3/i" 0.08 lb.
80051 40 3/ 0.11 lb.
80052 11/4" 40 3/4U 0.20 lb.
80053 1'/2" 80 '/15" 0.31 lb.
80054 80 8/4" 0.56 lb.
80055 21/2" 80 3/41 0.89 lb.
80056 80 1" 1.19 lb.
I Part I
I Size I
I 1/0 IWtI
I2llb.l Sch.I Ii No.1
180032 1" x /"I 40 I 13/ 10.161
Part No. Size Sch. T/O Wt
80025 3/4"40 °/is" 0.09 lb.
80026 40 3/li 0.14 lb.
80027 Vi." - 40 'Is" 0.21 lb.
80028 11/2"
-
80 V/is" 0.40 lb.
80029 80 Vi." 0.79 lb.
1.80030L 21/2" 80 1'k" 1.14 lb.
80031 80 1/is" 1.82 lb.
Part No. Size Sch. T/O I Wt.
80000 3/4fl 40 5/i" 0.11 lb.
80001 1' 40 3/4 0.19 lb.
80002 Vi." 40 '/" 0.26 lb.
80003 1 1V2" -. 80 1" 0.51 lb.
80004 80 13/" 0.90 lb.
80005 21/2" 80 1°/is" 1.59 lb.
80006 80 in/is 2.41 lb.
I Part
I No.
I
I Size .Sch.I I I
I T/0 IWt.l I I lb. I 1 I 2 I
180015 1, x /4"I 40 I Ii/'I In/isn I 0.281
Part No. Size Sch. 1/0 Wt.
80009 3/4"40 °/,s" 0.13 lb.
80010 40 0.23 lb.
80011 11/4 40 °/is" 0.34 lb.
80012 11/2" 1 80 1 i'/is" 0.67 lb.
80013 80 1/s" 1.00 lb.
80014 2'/2" 80 1°/is" 1.91 lb.
80008 80 V3116" 9.89 1b.
TIO
Reducer
Bushing
Part No. Size Sch. 1/0 I Wt.
80200 10 x 40 i/i," 0.04 lb.
80201 11/4" x 36" 40 7/,, 0.11 lb.
80202 11/4" x 1" 40 '/i " 0.12 lb.
80203 11/2" x 36" 80 'Is" 0.16 lb.
80204 V/i" x 1" 80 14" 0.14 lb.
80205 11/2" X 11/40 80 s/S' 0.17 lb.
80206 2" x 3/4' 80 3/40 0.27 lb.
80207 20 x 10 80 "I,," 0.26 lb.
80208 2" x 11/4" 80 '/i " 0.24 lb.
80209 x 11/50 80 7/0 0.19 1b.
80215 21/2" x 1" 80 V'/ie" 0.42 lb.
80214 21/2" X 11/4 ' 80 1'k" 0.45 lb.
80213 21/2" x 11I" 80 1'/e" 0.461
80211 2½" x 2" 80 1'/,," 0.29 lb.
80210 x 20 80 2'/ie" 0.72 lb.
80212 3" x 2'/s" 80 IIBiU 0.47 lb.
JrrL1
Reducing
E
+-
jT/O
Tee i_LLJ r
T10'J..LI-T/O'
It
-T/O TO
Coupling
--EiE-- Cap --E---
Part No Size Sch. T/O Wt.
80075 3/40 40 IA" 0.07 lb.
80076 1' 40 '4" 0.11 lb.
80077 1'/4" 40 '/i " 0.12 lb.
80078 V/2" 80 she" 0.25 lb.
80079 2" 1 80 3/,," 1 0.38 lb.
80080 21/a" 80 3/,," 0.67 lb.
80081 30 80 1 'lie" 1 0.91 lb.
TIC
Grooved -
Coupling Pipe O.D.
Adapter
Part No. Size Sch. 1/0 Wt. Pipe OD
80160 11/4" x 11/4" Grooved 40 2-h.- 0.78 lb. 1-h- (1.660")
80161 11/2" x 11/2" Grooved 80 2 /,e" 0.95 lb. 11b" (1.900")
80162 20 x 20 Grooved 80 2 -h." 1.42 lb. 2" (2.375")
80163 21/2" X 21/2 ' Grooved 80 2 Vie" 2.28 lb. 21h- 2.8750)
80164 3" x 30 Grooved 80 2'I4" 3.00 lb. 30 (3.500")
80168 3" x 76.1 mm Grooved 1 80 21/4" 2.72 lb. 76.1mm (3.000")
Part No Size Sch. T/O Wt.
80100 '/4" 40 e/,lI 0.04 lb
80101 1° 40 'I," 0.06 lb.
80102 11/4" 40 1/2" 0.10 lb.
80103 11/2" 80 '4" 0.20 lb.
80104 801 '/." 0.31 lb.
80105 2V2"1 50 /e" 0.58 lb.
80106 1 80 1" 1 0.88 lb.
1/0
Female
Adapter
Part No. Size Sch. 1/0 Wt
80142 2/40 X 3/4" NPT 40 '/0" 0.41 lb.
80145 x 1" NPT 40 36" 0.63 lb.
80146 11/4" x 1114" NPT 40 W' 1.03 lb.
80147 11/" x 11/2" NPT
R800-
10 1.42 lb.
80148 x 20 NPT 1'!," .66 lb.
110
Male
Adapter E;;j
Part No. Size Sch. I 1/0 I Wt
80157 1/4" X 5/40 NPT 40 1 1'!,," 0.33 lb.
80158 10 x 1" NPT 40 1%"I 0.561b.
Reducing -
Coupling
Part No.1 Size I Sch. T/0 Wt.
[80220 1 1" x 5/40 401 1/en 0.08 lb.
Part
No. Size - Sch. 1/0 Wt
1 lb. -:;- - 3
80132 /4" X '/4" x 10 40 /4" 5/40 /,0 0.14
80133 1" x 'I." x /." 40 '/" /i6" '/" 0.14
80134 10x 3/40 xl" 40 '/4" 'I." 0.17
80260 10 x 10 x 3/40 40 3/40 5/4" "I,," 0.16
80135 11/4" X 1" X 5/4" 40 '/,," '/" /15" 0.21
80136 11/4" x 1" x 1" 40 - /ie° 3/4" i/,," 0.22
80137 11/4° X 1" x 1114" 40 3/,,,' "/is" 13/4" 0.26
80261 11/4" X 11/40 X 3/40 40 'I," C/i" 7/," 0.23
80262 11/4" X 11/4" x 1" 40 3/40 3/40 7/0 0.26
80138 11/40 X 11/40 x 1 ½" 80 10 1" 1" 0.43
80140 11/2" X 11/40 5/0 80 '/z" 'I," 1" 0.36
80141 11/2" X 11/4" x 10 80 '/" 'I." i'l" 0.38
80263 11/2" x 11/2" x 3/40 80 '/t " she" 1" 0.36
80264 11/2" X 11/2" x 1" 80 /,," 'Ii," 10 0.38
80275 11/2"x 11/2" X 11/4" 80 7/," 7/," 1" 0.45
80265 2"X2"X 3I4" 80 3/40 2/40 1'/" 0.61
80266 2" x 2" x 1" 80 7/0 7/5" 1/6" 0.66
80274 2"x 2"x 11/40 80 1" 1" 1 3/," 0.74
80267 2" x 2" x 11/2" 80 VI." 1'!." VI." 0.78
80271 21/2" x 21/2"x 1" 80 1"!,.' ll,,"" 11!,," 1.43
80272 21/2"x 21/2" X 11/4"
-. 80 -
- la/i." -
- "hell - 1°/i," -
1.46
80273 21I2" x 2112" x V/a" 80 i"lie" -
1"/ie"
-.
V/ is" 1 .48
80276 2'/" x 2'/a" x 2" 80 1"/,e" 1"!,," 11s',," 1.50
80270 3" x 3"x 1'l? 80 - 1 1"/,," 2.28
80268 3" x 3" x 2" 80
i
t"
"
-
j3/40 2.25
-
80269 30 x 30 x 2'I" 80 " 116/e" 0.44
Sprinkler Head Adapter
with Brass Threaded Insert J
Part No. Size Sch. TIC Wt.
80175E 3/40 X /2" NPT 80 1/0 0.20 lb.
80176E X 1/2" NPT 80 7 022 lb.
80177WL 3/4" x 1/20 NPT 40 she 0.16 lb.
80179 1 x 3/40 NPT 1 40 3k' 0.43 lb.
Sprinkler Head Adapter
(Spigot)
with Brass Threaded Insert L!!I
I Part No. Size Sch. T/O Wt.
I 80177L 2/4' x 1/20 NPT 40 1/2 0.16 lb.
80178 1"x 1/30 NPT 40 /a 0.20 lb.
Sprinkler Head Adapter
fi6
.
with Brass Threaded Insert
Part No. Size Sch. I/O Wt.
80175W 3/0 X /2' NPT 40 1 T/,0 0.19 lb.
80176W lx 1/20 NPT 40 1 "/is" 0.18 lb.
Part
No. Size Sch. I/O Wt.
lb. 1 2
80462 10 X 10 X 1/20 NPT X W' NPT 40 6/50 1'/s" 0.46
80463 1 x 10 x W' NPT x 1/0 NPT 40 'Ian 16/isO 1 0.47
Back-to-Back Cross
with Brass Threaded Insert
Sprinkler Head Adapter
90° Elbow
with Brass Threaded Insert Back-to-Back Tee
with Brass Threaded Insert
Part •
No. Size Sch. T/O Wt.
lb. 1 2
80199 3/4*X V2" NPT 40 5/50 15/l 0.20
80189 1" X 1/20 NPT 40 13/50 11 3/50 1/,s' 0.26
Sprinkler Head Adapter
4TO-i
f'"J, Tee
with Brass Threaded Insert
Part
No.
Size Sch. I/O wt.
lb. 1 1 2
80459 1 x 1/2' NPT x 1/20 NPT 40 Ii/0 1/i." 0.48
80460 1"x /2' NPT x /2° NPT 40 Ii/1 V/e° 0.46
Part
No. Size Sch. TIC Wt.
lb. -r r -r
80250 3/lI x 3/0 x 1/20 NPT 40 6/ill 5/0 10 0.22
80251 1"x 1' x 1/20 NPT 40 11/0 11/fl' i3/0 0.29
80249 1"x 10 x 10 NPT 40 16/150 16/a" l'/is" 0.73
80256 11/411 x 1' x 1/20 NPT 40 7he 9/0 1 1'/s' 0.30
80252 1I/411 x 11/4" x 1/20 NPT 40 7/0 1/0 I/' 0.31
80257 11/2' X 11/40 x 1/5° NPT 80 Via" '/s" 17/isO 043
80254 11/2"x 11/2' X /2 NPT 80 6/is' /t6" 17/isO 0.46
80258 2' x 11/2" x 1/? NPT 80 1/20 5/0 1/." 0.56
80253 20 x 2"x 1/20 NPT 80 1/5' 1/50 li/s" 062
LImited Warranty
Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defect. In material and workmanship when paid for and properly Installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Product.. No warranty I. given for products or compon.nts manufactured by compact.s not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse. Improper InstallatIon, corrosion, or which have not been Installed. malntaln.d, modified or repaired In accordance with applicable Standards of the National Fire Protection Association (NFPA). and/or th. standards of any other Authorities Having
~ajs`
tion.l found byTycoFire Products Tycduct, neither assumes,nor aut
of products or parts of product.. Tyce Fire Products shall not be responsibi. for sprinkler system design errors or Inaccurate or Incomplete Information supplied by Buyer or Buyer's representative..
IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY. FOR INCIDENTAL. INDIRECt SPECIAL OR CONSEQUENTIAL DAMAGES. INCLUDING BUT NOT LIMITED TO LABOR CHARGES. REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES. AND UI NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILiTY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE.
THE FOREGOING WARRANTY IS MADE IN LIE OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPT1EI. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
tqco/Rowconvi/
?Yof&OE raqAtM0#41 A0 VW8 xd .LiXd.l8t©jt..4.
od AQt4O?