HomeMy WebLinkAbout2290 COSMOS CT; ; FS050006City of Carlsbad Fixed Systems Permit Permit No: FS050006 Job Address: 2290 COSMOS CT Permit Type: FIXSYS Parcel.No: 2130504400 Lot, #: 0 Reference No.: Status: ISSUED Applied 3/28/2005 Approved: 4/11/2005 Issued: 4/11/2005 PC #: Inspector: Project Title: SIERRA WIRELESS SPECIAL CHEMICAL PLAN CHECK & INSPECTION Applicant: SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 Owner: GRANDONA INVESTMENT ASSOCIATES L P 2610 HARRISBURG AVE FREMONTCA Fees ($) Add'I Fees ($) Total ($) Balance ($) 115 0 115 0 FSoSOa 'tSchmi,Jt Fire PrOtBEHNI Ca., Inc. 11 4760 MURPHY CANYON RD • SAN DIEGO, CA 92123 • (858) 279-6122 • FAx (858) 279-3583 S SIERRA WIRELESS 2290 COSMOS CT. CARLSBAD, CA 92009 (1) FM-200 FIRE SUPPRESSION SYSTEM ANECHOIC CHAMBER CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Bublect to field inspection and required tests, notations hereon, conditions in correspondence and conformance with appiicabiejqgulatiOflS. The stamping of tØe ps shall not be held to f enT ritbwoIation of any law I eao/a/zb,z • 4k2 c fr Kidde Fire Systems JAMES MOORE SCHMIDT FIRE PROTECTION CO. 4760 MURPHY CANYON RD. SAN DIEGO, CA Phone: PH: 858-279-6122 FAX: 858-279-3583 ECS Series - KID3.03 UL: EX4674 Project Sierra Wireless File Name: Sierra Wireless-262.FLC Consolidated Report Customer Information Company Name: Sierra Wireless Address: 2290 Cosmos Ct Carlsbad, CA 92009 Phone: Contact: Title: Project Data Project Name: Sierra Wireless Designer: Chandra O'Neal. Number: Account: Location: Anechoic Chamber Description: Kidde Total Flooding FM-200 Fire Suppression System Designer Notes Preliminary Design Documents Page: lof5 Calculation Date/Time: Thursday, March 17, 2005, 7:36:47 AM Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal AV Kidde Fire Systems Consolidated Report Enclosure Information Elevation: 0 ft (relative to sea level) Atmospheric Correction Factor: I Enclosure Number: I Name: Anechoic Chamber Enclosure Temperature... Minimum: 70F Maximum: 72 F Maximum Concentration: 6.285% Design Concentration... Adjusted: 6.260% Minimum: 6.250% Minimum Agent Required: 91.9 lbs Width: 0.0 ft Length: 0.0 ft Height: 0.0 ft Volume: 0.0 cubic ft Non-permeable: 0.0 cubic ft Total Volume: 3040.0 cubic ft Adjusted Agent Required: 92.0 lbs Number of Nozzles: I Page: 2 of 5 Calculation Date/Time: Thursday, March 17, 2005, 7:36:47 AM Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal lKidde Fire Systems Consolidated Report Agent Information Agent: FM-200 I Propellant N2 (FM-200 is a Trademark of Great Lakes Chemical Corp.) Adjusted Agent Required: 92.0 lbs Container Name: 125 lb Cylinder Container Part Number: 90-100125-001 Number of Main Containers: I Number of Reserve Containers: 0 Manifold: No Manifold Pipe Take Off Direction: Horizontal Agent Per Container: 92.0 lbs Fill Density: 51.5 lbs I cubic ft Container Empty Weight 96.0 lbs Weight, All Containers + Agent 188.0 lbs Floor Area Per Container: 0.89 square ft Floor Loading Per Container: 211 lbs /square ft Pipe Network Part I - Pipe Pipe Description Start End Type Diameter Length Elevation Main Cyl. X 1 0 1 1-1/2 in 2.99 ft 2.99 ft Pipe 1 2 40T 1-1/2 in 1.00 ft 0.00 ft Pipe . 2 3 40T 1-1/4 in 11.34 ft 11.34 ft Pipe 3 4 40T 1-1/4 in 8.25 ft 0.00 ft Pipe 4 5 40T 1-1/4 in 7.50 ft 0.00 ft Pipe/El-NI 5 6 40T 1-1/4 in 2.00 ft -2.00 ft Part 2- Equivalent Length Start End 90 45 Thru Side Union Other Added Total 0 . 1 0 0 0 0 0 ---------------- 0.00 ft 50.0 ft 1 2 0 0 0 0 0 0.00 ft 1.0 ft Page: 3 of 5 Calculation Date/Time: Thursday, March 17, 2005, 7:36:47 AM Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Kidde Fire Systems Consolidated Report Part 2- Equivalent Length Start End 90 45 Thru Side Union Other Added Total 2 3 1 0 0 0 0 0.00 ft 15.0 ft 3 4 1 0 0 0 0 0.00 ft 12.0 ft 4 5 1 0 0 0 0 0.00 ft 11.2 ft 5 6 1 0 0 0 0 0.00 ft 5.7 ft Part 3- Nozzles Start End Flow Name Size Type Nozzle Area 0 1 92.01bs ------------ I 2 92.0lbs 2 3 92.01bs 3 4 92.01bs 4 5 92.01bs 5 6 92.0 lbs El-NI 1-1/4 in 3600 0.6765 square in Parts Information Total Agent Required: 92.0 lbs Container Name: 125 lb Cylinder (Part: 90-100125-001) Number Of Containers: I Nozzle Type Nozzle Area Part Number El-NI 3600 0.6765 square in 90-194026-328 Pipe: Type Diameter Length 40T 40T 1-1/4 in 1-1/2 in 29.09 ft 1.00 ft List of 90 degree elbows: 4- 1-1/4 in System Acceptance Page: 4of5 Calculation Date/Time: Thursday, March 17, 2005, 7:36:47 AM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal fKidde Fire Systems Consolidated Report System Discharge Time: 8.9 seconds Percent Agent In Pipe: 33.1% Percent Agent Before First Tee: 0.0% Enclosure Number: I Enclosure Name: Anechoic Chamber Minimum Design Concentration: 6.250% Adjusted Design Concentration: 6.260% Predicted Concentration: 6.261% Maximum Expected Agent Concentration: 6.285% (At 72 F) Minimum Adjusted Predicted Nozzle Agent Agent Agent Pressure Nozzle Required Required Delivered (Average) El-NI 91.9 lbs 92.0 lbs 92.0 lbs 134 psig Standard Isometric View Page: 5 of 5 Calculation Date/Time: Thursday, March 17, 2005, 7:36:47 AM Copyright (C) Hughes Associates, Inc. Licensed to Kidde-Fenwal ® 174 X 1/4 x 8'-3" PIPE 1,4II x 1A" PIPE ELECTRIC ACTUATOR 125 LB. CYLINDER w/2 LBS. FM-200 NOZZLE PART NUMBERS: El-NI: 0-194026-328 (0.75 SQ.IN.) 1/4 360 PIPING ISOMETRIC 125 LB. CYLINDER N.15. rNOTE: 3 ERDf / ALL PIPES ARE SCHEDULE 40 L MEASUREMENTS SHOWN ARE CENTER T ALL FITTINGS To BE 300 LB. MINIMUM FM20011 Fire Suppression Agent EFFECTIVE JAN 1999 P/N 90-1 90000-OOX 90.1900.1 Features Non-Ozone Depleting • Safe for Total Flooding of Occupied Spaces Clean-No Residue to Clean Up • Non-Damaging to Hazard Contents Fast Acting • Active Fire Suppression Agent UL Component Recognized • FMRC Approved EXTINGUISHING AGENT FM-200 (1,1,1 ,2,3,3,3-heptaflUoropropane) is a compound of carbon, fluorine and hydrogen (CF3CHFCF3). It is color- less, odorless and electrically non-conductive. It suppresses fire by a combination of chemical and physical mechanisms without affecting the available oxygen. This allows personnel to see and breathe, permitting them to leave the fire area safely. FM-200 has acceptable toxicity for use in occupied spaces when used as specified in the United States Environmental Protection Agency (EPA) Significant New Alternative Policy (SNAP) program rules. Although FM-200 is considered non-toxic to humans in concentrations neces- sary to extinguish most fires, certain safety considerations should be observed when applying and handling the agent. The discharge of FM-200 may create a hazard to personnel from the undecomposed agent itself and from the decompo- sition products which result when the agent is exposed to fire and other hot surfaces. Exposure to the agent is gener- ally of less concern than is exposure to the decomposition products. Unnecessary exposure to the agent or the decom- position products should be avoided. Toxicity: In tests, the acute toxicity of FM-200 was shown to be equivalent to that of Halon 1301. FM-200 has been evaluated for cardiac sensitization through test protocols approved by the US EPA. The EPA's SNAP Program classi- fies FM-200 as acceptable for use as a total flooding agent in occupied spaces. Refer to the SNAP program rules for more information. Cleanliness: FM-200 is clean, leaves no residue, thereby eliminating costly after-fire clean-up, and keeping expensive "down-time" to a minimum. Most materials such as steel, stainless steel, aluminum, brass, and other metals as well as plastics, rubber and electronic components are unaffect- ed by exposure to FM-200. This literature is provided for informational purposes only. KIODE-FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The product must be properly applied to perform as described herein. It you need more information on this product, or if you have a question, contact Kidde- FENWAL INC., Ashland, MA 01721. (SOB) 881.2000. 90.1900.1 2199 5M 01995 KIDDE-FENWAL, INC. Printed in U.S.A. CP 6-MMEG KIDDE.FENWAL, INC. 400 MAIN STREET ASHLAND, MA 01721 Fire Systems (508) 881-2000 FAX: (508) 881-8920 FM-200 Physical Properties Chemical Formula CF3CHFCF3 Molecular weight 170.03 Freezing point -204F (-131 C) Boiling point at 1 atm. 2.6F (-16.4C) Critical temperature 215.1-F (101.7-C) Critical density 38.76 lb/ft' (621 kg/m3) Critical pressure 422 PSIA (29.0 bar absolute) Critical volume 0.0258 cu.ft./lb. (1.61 1/kg) Ozone Depletion Potential 0 FM-200 Fire Protection Properties Cup burner concentration (n-heptane) 6.7% v/v Use concentration for n-Heptane 8.0% v/v Use concentration for Acetone 8.3% v/v Use concentration for Isopropanol 9.0% v/v Use concentration for Toluene 7.0% v/v Use concentration for Class A (Surface Fires) 7.0% v/v FM-200 Toxicity Properties NOAEL 9% (No Observable Adverse Effect Level) LOAEL 10.5% (Lowest Observable Adverse Effect Level) Approvals: FM-200 agent complies with the NFPA Standard 2001, Standard for Clean Agent Fire Extinguishing Systems, EPA SNAP Program, (Significant New Alternate Policy), Underwriters Laboratories, Inc. (UL) Factory Mutual Research Corporation (FMRC). Use: FM-200 is used in total flooding fire suppression sys- tems. It is stored in steel containers, and is super-pressur- ized with nitrogen to aid in expelling the agent. The dis- charge time is 10 seconds or less. The maximum fill density of the agent storage is 70 lb/ft3. FM-200 is a Registered Trademark of Great Lakes Chemical Corporation ORDERING INFORMATION P/N DESCRIPTION 90-100121-001 W/LLI 90-100125-001 STD P/N: 90-10012X.001 01101CM6 Fire Systems I000EFErMM.. W- 400 1M54 STREET 4314t4140, MA 01121 TEL (SOS) u14000 FAX (SOS) elt.ISOO .FM-200 Component Description Effective: April 1999 Cylinder and Valve Assembly 125 LB (56.7 KG) Capacity Features For use with UL listed. ULC listed & FMRC approved systems VALVE OUTLET PLAN VIEW SAFETY CAP CYLINDER VALVE 35.93• 31.9 itO LEVEL INDICATOR IFTING LUGS CYLINDER CYLINDER NAJilEPtATE 12jr DIA NOTES: THE SAFETY CAP MUST BE INSTALLED ON THE VALVE OUTLET AT ALL TIMES EXCEPT WHEN THE CYLINDERS ARE CONNECTED TO THE SYSTEM PIPING OR BEING FILLED. THE SAFETY CAP MUST NOT BE REMOVED FROM ITS CHAIN. SEE K-90-2020 FOR ADDITIONAL INFORMATION. MATERIALS VALVE BOCY: BRASS CYLINDER: STEEL, PAINTED RED This Iiwature is provided fOr inblnabonal paposss cid KIDOE.FENWAL. INC. assurss no responsibility for the produ, suitability for. pWitadv spØbon The produd nwst be propsity applied to psifonO as dswtbsd hired. If you v.sd mare infannedon on this plOdud. or Wyai have a qusslian. canlad KIDDE. FENWAL. INC.. AsNand, MA 01721. (508) 881.2000. K-90-2030 4199 01999 Ktddi.Fsnwal, Inc. P.tnt.d In USA FM-200 Component Description Effective: AprIl 1999 • 360 Degree Pendant Nozzle K-90-2140 Features For use with UL listed, ULC listed & FMRC approved systems • See KIDDE Manual 90FM200M421 for USCG approval IN .093.031 HIGH CHARACTERS ON ANY FLAT 360 DEGREE NOZZLE Pipe Sin A B C D 112' (12.20mm) 1.250' (31.75mm) 1.468' (37.26mm) 1.937' (49.19mm) 1.250' (31.75mm) 314' (19.05nvuI 1.500' (36.10mm) 1.578' (40.08mm) 2.125' (53.97mm) 1.500' (38.10mm) V (25.40mm) 1.750' (44.45mm) i.iir (43.63nwn) 2.378' (60.32mm) 1.750' (44.45mm) I-114 (31.75mm) 2.250' (57.15mm) 1.950' (49.53mm) 2.750' (69.85mm) 2.250' (57.15mm) 1-112' (38.10mm) 2.250' (53.S0mn) 2.000' (50.80mm) 2.937' (14.59mm) 2.500' (63.50mm) 2' (50.80mm) 3.000' (76.20mm) 2.062' (52.37mm) 3.128' (79.37mm) I 3.000' (18.20mm) A SELECTION OF ORIFICES ARE AVAILABLE FOR EACH NOZZLE SIZE. CONSULT YOUR KIDDE DE- SIGN AND INSTALLATION MANUAL FOR DETAILS P/N: 90-19402X-XXX. I This Ilterstum is provided for tefonnatlonat purposes only. KIODE.FENWAL INC. i mia DDE° assumes no responsibility for the products suitability for a pamitcular application. The product must be properly applied to perform as described herein. I If you need more Information On this Product or If you have a question, canted KIDDE. Fire Systems FENWAL INC.. Ashland. MA 01121. (508)881-2000. I KI00E.ENWAil, INC. 400 MAIN STREET. *5111)140. MA01721 K-SO- 4199 01999 Kldde-fenwsl. Inc Printed in USA TEL (508)81-2000 F*5 (508)881.8690 FM-200 Component Description Effective: April 1999 Electric Control Head, Stackable Explosion Proof K-90-8017 Features 'For use with UL listed, ULC listed & FMRC approved systems ELECTRIC CONTROL HEAD, PART NO. 486500-01 IS RATED FOR USE IN HAZARDOUS (CLASSIFIED) LOCATIONS CLASS 1, DIV. I, GROUPS C, D AND CLASS II, DIV. II, GROUPS E, F, G BETWEEN -40F AND 140F. USE CONDUIT SEAL WITHIN 18 IN. (45cm) OF THIS DEVICE. -F-2A 1/2"-14 NPT CONDUIT CONNECTION MG-LEADS IG SRI A WARNING ELECTRIC CONTROL HEAD, PIN: 486500-01, IS DE- SIGNED FOR INSTALLATION DIRECTLY ON 487 AND KNC SERIES HALON AND ECS SERIES FM-200 VALVES ONLY. THIS CONTROL HEAD MUST NOT BE INSTALLED ON ANY OTHER TYPE OF HALON OR FM- 200 CYLINDER VALVE, NITROGEN VALVE, CARBON DIOXIDE CYLINDER VALVE, FE-13 CYLINDER VALVE OR STOP (DIRECTIONAL) VALVE. INSTALLATION OF THIS CONTROL HEAD TO ANY OTHER DEVICE (E.G., PRESSURE OPERATED CONTROL HEAD) WILL RE- SULT IN FAILURE OF DEVICE TO OPERATE. YVIVL. riu I 1.25-18 UNEF-213 CONNECTION VOLTAGE: 24VDC CURRENT: 0.2A CONTINUOUS DRAW PIN: 486500-01 assumes no responsibility for the product's suitability for a particular application. The I This literature is provided for informational purposes only. KIDDE-FENWAL. INC.MMDM I product must be properly applied to perform as described herein. I If you need more Information on this product, or If you have a question, contact KIDDE. Fire Systems FENWAL, INC., Ashland, MA 01721. (508) 881-2000. i I KIDDE-FENWAL, INC. I(-90-8017 4/99 01999 Kidde.Fenwal, Inc. Printed In U.S.A. 400 MAIN STREET. ASHLAND, MA0I72ITEL: (508) 881-2000 FAX: (508) 881.8920 FM-200 Component. Description EffectIve April 1999 100 Valve Outlet Adapters Features . For use with UL listed, UIC listed 8 FMRC approved systems • See KIDDE Manual 90-FM200M-021 for USCG approval B (VALVE OUTLET CONNECTION) C A (SYSTEM PIPE CONNECTION) ORDERING INFORMATION PART NO. SIZE A D 283904 . 1-1/2 1-1/2 11-II2NPT 1.874 12UNJ 2.69 2.50 HEX 283905 2 2 2.500 12 UK)3.12 3.00 HEX 11-1/2 NPT 283906 2-112 2-1/2 3.00 300 3.75 HEX 8NPT I2UMJ * DIMENSIONS ARE IN INCHES MATERIAL: BRASS NOTE: FOR DIRECT CONNECTION OF CYLINDER VALVE TO DISTRIBUTION PIPING. PIN: 28390X This literature Is provided for Infomiatlonal purposes ci4 KIODE-FENWAt. INC. J assumes no responsibThty for the ~a suitability for a particular application. The I I'JDDE product must be property applied to perfonnas described hereto. I If you need more Information on this product, or If you have a question, canted KIODE- i Fire Systems . FENWAL, INC.. Ashland, MA 01721. (508) 881-2000. I KIODE-FENWAI,, INC. K-90-2100 4599 01999 Kldde-Fenwal, Inc. Printed In USA 400 MAIN STREET.ASHLANC. MA0I2I EL (508)181-2000 FAX TEL:(501)881.1920 Effective: Apr11 1999 FM-200 Component Description Warning Nameplate (FM-200) K9o9O3o Features For use with UL listed, ULC listed & FMRC approved systems • USCG approved 10.000 .063 .340 —s 9.360 .340 WARNING THIS AREA IS PROTECTED BY A .062 FM-200EXTINGUISHING 5.000 SYSTEM. DO NOT ENTER WITHOUT AUTHORIZATION DURING OR AFTER DISCHARGE _ ( 4.360 .281 .005 DIA. TYP. 4 HOLES MATERIAL: ALUMINUM TYPE 1100-H14 OR 3003- H14, .032 ±.003 THICK. ALL LETTERS TO BE 48 PT. ALTERNATE GOTHIC 02. ETCHED .003 -.005 & FILLED IN WITH RED CHIP PROOF ENAMEL COLOR NO. 21105 PER FED. STC. 595 PIN: 06-231885-739 FINISH: ONE COAT CLEAR LACQUER BOTH SIDES IThillbookS bpowide ur neNonsI pwpøsis only. l000E-pEPIWAL INC. i • IJ DDE stmno no mpone5Iy for the prodis uulb5Iy s porSMr 1i41&.&.... The iroist be popily 1ppi.db porfonn Jefod herebi. I I N you need more WUm&.flon INS FOO.4 or 9 VW low a qnsihn. KIDDE. Fire Systems FEPMM., INC.. AsN.n6, VA 01721. (505) 131.2000. KIDDE-FEWA4L. INC 400 MAIN STREET. ASHLAND. Me 01P21 K4"=4159 01059 I0dd..ferv. . Sc Pfl'5sGI U.S.A TELL INS) 131.2000 MX(M) 5814220 Gemini II Multi Hazard Effective: December 2001 Conventional Suppression Control System 84-003 I P/N 84-32200X-XOX FEATURES Microprocessor based Programmable • Remote Hazard Control UI. & ULC Listed, FM Approved • Remote Display Units for Local or Global Repeat CSFM & MEA Approvals pending Annunciation Listed for FM200, FEI3, CO and HALON Clean • Completely and easily field programmable Agent Suppression System2s. Also for Sprinkler • 80 character alphanumeric LCD Display Supervisory, Deluge and Preaction Systems. • 270 evenI!sto,y buffer Suitable for KiddéIND Dry Chemical and WHDR Wet Chemical Systems. DESCRIPTION The Kidde Gemini II is a microprocessor based program- mable Suppression Control System designed for operation with Conventional Fenwal Ionization and Photoelectric Smoke Detectors. In its simplest configuration, the Kidde® Gemini II Main Control Panel (MCP) is a single hazard Con- trol Panel that can be field-expanded to be a large 8 hazard Control System with multiple Remote Display Units. Sys- tem expansion is achieved by adding up to 7 Remote Haz- ard Units (1 RHU per added Hazard) and up to 16 Remote Display Units (RDU). The MCP communicates with the RHUs and RDUs on a dual path Style 7 RS-485 network, monitors their status and displays system wide messages. SYSTEM COMPONENTS MAIN CONTROL PANEL (MCP) MCP Power Supply: The MCP operates on 120/240 Vac 50/60 Hz Power Sup- ply. The Power Supply Unit is rated 4 Amps at 24 Vdc and is provided a Battery Charger to charge a 24 Vdc backup Bat- tery. The Battery may be sized for 24 hour Standby with 5 minutes Alarm or for 90 hour Standby with 10 minutes Alarm depending on the Suppression System. The Power Supply causes an immediate changeover to battery in case of loss of AC input or drop in input voltage. MCP Display Panel: The MCP Display Panel is provided with an LCD Display, five status LEDs and a local buzzer. It also includes four system control buttons and four menu control buttons (see Figure 1). MCPVtO SYSTEM STATUS NOt —. '250 02.50-01 L pd.M SUPO TILOO K1DDE -1 .:;TS. Figure 1. MCP Display Panel MCP Hazard Block: The MCP controls one Hazard Block and is provided tt following Input Circuits: 2 Style B or Style D Initiating Circuits, each of whic can support 40 Fenwal Smoke Detectors 1 Style B Manual Release Circuit for N.O. devices 1 Style B Abort Circuit for N.O. devices 1 Style B Supervisory Circuit for N.O. devices I Style B or Style 0 Waterflow Circuit for N.O. devicu The MCP is provided the following Output Circuits: 2 Style Y or Style Z Indicating Appliance Circuits ratu 2.5 Amps total at 24 Vdc for polarized A-V signals. 1 Style V Agent Release Circuit rated 3.4 Amps max 24 Vdc. The circuit can be configured for Kidde Cont Head Solenoids for Clean Agent Systems or for F Group A, B, D. E or G Solenoids for Deluge and Pt Action Systems. RDU #5 for RDU #4 for RHU #2 RDU #3 for RHU #2 Main Control Panel RDU #1 for MCP 24 Vdc 17. I I iWo independent Style 7 ED RS-485 Data Pairs. Max. ED length 4,000 ft. each. 1° - I RHU #2 11100011L %F C I w/o Display t201240 f RHU #1 1201240 It Vac WI Display I Vac 24 Vdc I 1i111 24 Vdc RDU #2 for RHU #1 Not.: The system must comprise I MCP. To expand, add up to 7 ROWs and up to 16 ROUs to the network. Figure 2. Typcial System Block Diagram The MCP also provides the following Relay Outputs: SYSTEM COMPONENTS 1 Form C System Alarm Relay REMOTE HAZARD UNIT (RHU) 1 Form C System Trouble Relay 1 Form C Programmable Relay 5 Form C Programmable Relays (on socket mounted Optional Relay Board) MCP Programming: All programming is done via the MCP keypad. When the System is initialized, the MCP downloads the Operating Con- figuration to the RHUs and RDUs. MCP Enclosure: The MCP enclosure is rated NEMA 1 for indoor use. It is constructed of 18 gauge steel, painted red and kept closed by a steel door with a key-lock. All operator interface switches and indicators are located behind the locked cover. The enclosure is large enough to house two 12 Ah 12 Vdc bat- teries for backup supply. Battery Enclosures are available for larger capacity batteries. Optional dead-front enclosures are also available for use in Canada. 12Ah12Vdc 12Ah12Vdc Battery Battery Figure 3. Internal View RHU Power Supply: The RHU Power Supply Unit is exactly the same as that of the MCP. RHU Display Panel: The optional RHU Display (see Figure 4) can operate ei- ther in local or global mode. It is provided the same fea- tures as the MCP with the exception of the Menu Controls. © © RHU vo I LOCAL STAT AL 12:00 af 0-67 A&MOO SUPO TBLOO PSTEM CIT.2 FEMOTE WNW MIGMEWNT LJ o 0 0 0 0 rm -- .a .a, 'n © Figure 4. Remote Hazard Unit Display Panel RHU Hazard Block: Each RHU also controls one Hazard Block and is provided the same Input and Output Circuits as the MCP with the exception of the three System Relays. The Optional Relay Board (ORB) can also be mounted to the RHU. RHU Enclosure: The RHU Enclosure when using the Optional Display Panel is similar to that of the MCP. In the case that this option is not selected, the RHU Enclosure has no viewing window. Main Control Panel and Remote Hazard Units Inputs from. I field devices Detection Circuit # 1 I I RS485 2'StvieBoro I. I Port I I tt ''• 't'-iiL Detection Circuit #2 Smoke and I Style B or 0 Heal Detectors I .Waterfiow Input W —r Style B or D 1 Supervisory Signal Sprinkler System Style B !I _r Manual Release le 13 Pull Station Indicating Circuit # 1 Style V or Z Indicating Circuit #2 Style V or Z Release Circuit Style V Form C Alarm Relay - Form C Trouble Relay - Farm C Prog. Relay - 5 Form C Prog. Relays on Option Relay Board To and from other System Units Outputs Audible and Visual Indicating Devices Clean Agent Control Head Deluge System Solenoid Auxiliary Functions Equipment Shutdown - Repeat Annunciation - DACT (MCP only) IflflU *101 Abort Station 24 Vdc Auxiliary Power I (Not rsettabie) 24 Vdc Auxiliary Power 2 All relays except those on ORB are applicable to the MCP only. To Remote Display Units - Figure 5. Hazard Block Inputs and Outputs is SYSTEM COMPONENTS REMOTE DISPLAY UNIT (RDU) RDU Power Supply: The RDU operates on 24 Vdc Power received either from the MCP, its associated RHU or any other UL Listed source. RDU Display Panel: The RDU is a Display only unit and can be programmed to operate either in local or global mode. In local mode, it mim- ics the Display of the MCP or the RHU to which it is as- signed whereas in global mode, it mimics the display of the MCP. The RDU Display Panel provides an LCD Display, one Status LED and System Controls as shown in Figure 6. o 0 RDU V1.O SYSTEM STATUS NO.tAl. I r 12:00 0206-01 I ALMOO SUPO TBLOO ] !I1!U I IaDoE.I ' 0I*1IE DISPLAV U*1_J o 0 Figure 6. Remote Display Unit Display Panel RDU Hazard Block: RDUs may be used to accept one Manual Release and one Abort input from the local protected zone to which its asso- ciated MCP/RHU is assigned. RDU Backbox: The RDU Backbox is constructed of 18 gauge steel, painted red and kept closed by the Display Panel front plate. SYSTEM LOGS The Kidde Gemini II Control System is provided an Event Log and Configuration Log, both of which reside in the Main Control Panel. The Event Log is a compilation of all Alarm, Trouble, Supervisory and Event messages stored in non- volatile memory. Up.to a maximum of 270 events can be stored at any given time. The occurrence of a new event beyond the maximum capacity erases the earliest event. MENU STRUCTURE The Main Menu of the Kidde®Gemini II Control System con- sists of the following items as shown on the tree structure in Figure 7. Specific functions are password protected to limit access to authorized personnel only. Figure 7. Menu Structure ,urrent Draw: 3.0 Amps © 120 Vac or 1.4 Amps @ 240 Vac Output Rating: 4.0 Amps @ 24 Vdc Battery Charger Output: 3.5 Amps max © 27.3 Vdc Aux. Power Output: 0.5 Amp max © 24 Vdc âui QutRyper System: 1 Enclosure Rating: NEMA 1 Enclosure Material: 18 aauae steel. Dainted red Dimensions (WxDxH): 15.5" x 5.0" x 15.5" (393.7mm x 127mm x 393.7mm) Ambient Temperature: 32°F to 120°F (0°C to 49°C) max. Relative Humidity: 93% non-condensing max. TECHNICAL INFORMATION REMOTE HAZARD UNITS (RHU) Input Supply: 120/240 Vac 50/60 Hz Current Draw: 3.0 Amps © 120 Vac or 1.4 Amps © 240 Vac Output Rating: 4.0 Amps © 24 Vdc Battery Charger Output: 3.5 Amps max © 27.3 Vdc Aux. Power Output: 0.5 Amp max © 24 Vdc Quantity per System: Enclosure Rating: Enclosure Material: Dimensions (WxDxH): Ambient Temperature: Relative Humidity: Maximum 7 NEMA1 18 gauge steel, painted red 15.5" x 5.0" x 5.5" (393.7mm x 127mm x 393.7mm) 32°F to 120°F (0°C to 49°C) max. 93% non-condensing max. TECHNICAL INFORMATION ORDERING INFORMATION MAIN CONTROL PANEL (MCP) nput Supply: 120/240 Vac 50/60 Hz Part No. Description 84-322001-001 Gemini II Main Control Panel (MCP-ULI) 84-322001-003 Gemini II Main Control Panel (MCP-ULC) 84-322002-001 Gemini II Remote Hazard Unit with Display (RHU-ULI) 84-322002-002 Gemini II Remote Hazard Unit. vvithotl Display (RHU-ULI) 84-322002-005 Gemini II Remote Hazard Unit with Display (RHU-UL.C) 84-322003-001 Gemini II Remote Display Unit (RDU) 84-322001.009 Gemini II Optional Relay Board (ORB) 06-115915-047 12 Vdc, 12 Ah Seated Lead Acid Battery (2 required) 06-115915-046 12 Vdc, 17 All Sealed Lead Acid Battery (2 required) 89-100052-001 12 Vdc, 33 All Sealed Lead Acid Battery (2 required) 84-322004-001 Gemini 11 Battery Cabinet (for up to two 33 AH Seated Lead Acid Batteries) 06-129923-001 Resistor Kit (EOLs & Release Circuit Dummy). For design, installation, configuration and additional or- dering information, refer the Kidde° Gemini II Engineer- ing Manual P/N 06-235975-001. TECHNICAL INFORMATION REMOTE DISPLAY UNITS (RDU) Input Supply: 24 Vdc (nominal) Quantity per System: Maximum 16 Backbox Rating: NEMA I Backbox Material: 18 gauge steel, painted red Dimensions (WxDxH): 8.0" x 2.25 x 4.45" (203.2mm x 57.15mm x 113.03mm) Ambient Temperature: 32°F to 120°F (0°C to 49°C) max. Relative Humidity: 93% non-condensing max. IThus uteralure is provided for informational purposes only. KIDDE.FENWAIJNC. assumes nol IcIDDE responsibility to, the products suitability for a particular application. The product must be prop- erly applied to work correctly. . II you need more information on this product, or if you have a particular problem or question.1 1c0n1ac1 KIDDE-FENWAL INC. Ashland, MA 01121. Telephone: 500) 881.2000 Fire Systems 54-003 12/01 Kidde-Fenwal Inc. Printed in USA Kidde-Fenwal Inc. 400 Main Street, Ashland, MA 01721 Tel: (508) 881-2000 Fax: (508) 881.8920 is rx A$tYLEZ *. OCT. 1 aA&31nEa) 4.) E NOTE II drimm Nowsw am OP11CnALRtWNONO1Th1FONOC PROGRAMMASUE RELAYS TONOfl OT TO NEXT OEVS "M ISOL Lit MW VOL VIK Lit' S RrsaPdn ri twYr 4t — — — mom INSOMW MIWSS*I J.5 U I IM U - Kidde Gemini It Systeni APPENDIX E WIRING DIAGRAMS Sff NOTE 4) ISM NOTE a it ATA L__ rahm 1NOWRE5ETT4TIU MANG L. syvaai.c I$FbJ F wi 11 COWACTS ri C MENVEjamawnplawmVINEW C0HNVCNW*6V0OCj0jWC0lNVWLVANdL v=svwwUpw0vfi9ws oNOU$ 0 J 1H11 ' Vi'LOWaAA wc \ ST$LEO '5 g III ___ T9rf POCWO1II) mEt 0n, SO A&$TftEO WA. $EENaIE II smsm I.LTHOU614 WTI. o€i'a.mo W.R.OW ORCIJITSM( AmES ,o,sassg STYLE: 0 P SOtRIDER I HID STVES) S"OSIt2ClRCUIMARE9CNMASCLAS8A9MEZ THESE OCR RE WI AS ClASS B STYLE Cl E BMW CLAWS STYLEV $PECTiVBY. BRE FIGURE E-2 FOR OETM.S. L THE W4LU641P TM RELEASE cm DUMMY RESISTOR 3. FOR LTOF COMSET1ULE DEWICE, REF10APP94OIX S.. RECOMMENDED COLOR CODE FOR 4. STOP WLVES AM ONLY REOURES FOR COS SYSTEMS WITHCLUSTERIMCWHOERL Iwomscamc= ACVDWMWM I RG&WWA I - — FOR SUPERASWOACl2VTS scimwt I , Foot POWER LI CIRCU ROUTED - GIQ SEPARA1ftY FROM NCN.POWERUMITED —WIRES BY MORE ThAN % RICH. REFER TO FIGURE S-IS. 6.FORCOHFIOIJRAUCH OF SKORTRIG UNICS.. REFER TO FIGURE SE. 7. FOR DETAU OF RELEASE CROWTS. REFER TO AGUREE-7. 6. FOR DETAILS OF R5455 WRING. REFER TO FIGURE E-9. Figure E-1. MCP Wiring Diagram February 2002 E-1 06-235975-001 I I I I I I I Kidde Gemini H Systen, APPENDIX B LIST OF COMPATIBLE DEVICES B-I UL LISTED DEVICES A. Smoke Detectors, Bases and Accessories 10 Device suppler, Manufacturer Part Part No. Data File CID bri4on Smoke Osler CPD-7051 Kdde.Feqwmt 70610000.001 S1064. VoL 14. Sec, I 15IFEI PtuicelectIc Smoke Octecler PSD-7155 Cidde-fereml 71650000001 51064, Val. 13. Sec. 1 P55FEI PliscOic Smoke Detector for PSD-7155P I0dde-F.vv*el 715500004302 31064. Val. 13, S.c. 1 PSOFEI pkeloolscOlc Smoke Detector 35'F PSD-7156 Kidde-Fenavi 71560000001 S1064, "M. 13. Sec 1 P56FE1 2 Wie Der Base 2W6 OddeFaruol 70.501000.001 S1064. Vok 12. Sec. I FESIA WI 2 's Base vNRsnde LED ww Tom 2WRLT KIdde-Fel 70601000002 51064, VbL 12, Semi FE52A 2 WI's Detector or Base wf Remote LED wd Tait ZWRB Kidde-Feiwml 70601000.005 51064. VoL 12. Sec. I FE53A 06. Spare 2 WII. Riley Module 2WRM Kidde-Fesisel 704000004104 $1064. VIA 12, Sec I - Remote Alarm teceter R911 Kdde-Fesswal 70.200000.511 82438, VoL 1, Sec. 2 - Remote A1seWfëd h5calor RA914 ICIdde-Fe,,asl 70400000-914 S2438, VaL 1, S.c. 2 - $eltyder S1DO1 11(ldde-Fe,ya1 704000004)02 S2438, M. 2, Sec. 1 - Test Magret - Kidde-Fet7d,at 06.117883.001 - -. B. Duct Smoke Detectors and Accessories ID Device Model No. Supplied _ Part No. UUDab File CIO 01.1 Ocr v^*gral Usual 169 014-60(2W) lQdd.-Fenael 70-600000-200 S1064. Vol.8. Sec. 2 FE52A 02 2-Wre Did Hosasri W PSD-7 1550 01440(2W) IGdde-Feswal 70.600000-255 S1064, Vol. a Sec. 2 FE52A 03 1 2 -Wire OLd Hoiming Vd CPD-70510 014-60(2W) Kidde-Fenwal 70-600000-251 S104, Vol.8, Sec 2 FE52A 04. Did PtcteeIeIc Smoke Detector PSD-7155D Kidde-FUwial 71-550000.060 S 1064. Vat 13 Sec. 1 PSSFEI 05 Did keiaslion Smoke Detector CPD-70510 lOdde-Fenwal 70-510000-060 S 1064, vol. 14, Sec. I 1511FEI 06 12 Long Air Samping Tube - Kidde-fenal 06-129500.001 S 1064, Val. 14. Sec. 1 07. 24 Long Air saniplrg Tube - Kidde-Feiw,al 06-129500-002 31064. VoL 14. Sec. I - 06 48 Long Air Sampir0 Tube - Kldde-Fenwal 06-129500-003 S1064. Vol.14. Sec. I - 09. 72' Long Air Sãmp9rq Tt.be - Kldde-Fenwat 06-125900404 S1064. Vol. 14. Sec. I - 10..96' Long Air Sampling the - Kidde-Far,.val 06-129500.005 S1064. Vol. 14. Sec. 1 - 11 i 2W Long Air Sampling Tube - Kidde-Feiw,al 06-129500.006 S 1064. Vol. 14, Sec. 1 - 12. Opko'sI Etiet Tube Assembly - Kidde-Fenwal 06429554.001 S 1064, Vol. 14. Sec. I - February 2002 6-1 06-235975-001 KIDDE Welcome to go wow m' L!FBIIMAL FhiPrntectién! KIDDE-FENWAL Gemini II Fire ContrOl Panel (Ites Calculation Form is taken from Appendix W of the GEMINI It InstaIIation, Operation and Maint Manual) Data: 24-Mar-05 Project: Sierra Wireless 2290 Cosmos Ct. Carlsbad, CA 92009 ANECHOIC CHAMBER BATTERY CALCULATIONS QUANTITY Standby Current Load Total Standby Current Load Alarm Current Load Total frJann Current Load 1 0.1 amp 0.1 amp 0.28 amp 0.28 amp 0 0.5 amp 0 amp 0.5 amp 0 amp 0 0 amp 0 amp 0.03 amp 0 amp 1 0 amp 0 amp 0.03 amp 0.03 amp 0 0 amp 0 amp 0.04 amp 0 amp 2 0 amp 0 amp 0.13 amp 0.26 amp 0 0 amp 0 amp 0.171 amp 0 amp O 0.000045 amp 0 amp 0.038 amp 0 amp 2 0.000055 amp 0.00011 amp 0 amp 0 amp 2 0 amp 0 amp 0.07 amp 0.14 amp 0 0amp 0amp 0amp Oamp 0 0.00007 amp 0 amp 0 amp 0 amp 1 0 amp 0 amp 0.2 amp 0.2 amp 0 0amp 0amp 0.7 amp 0amp 0 0.025 amp 0 amp 0.035 amp 0 amp DEVICE Main Control Panel Auxiliary Power Output MCP Programmable Relay ORB Relays LED Display Module FIELD DEVICES: 15175 cd Ham/Strobe 75 cd Ham/Strobe 2-Wire Ionization Smoke Detector 2-Wire Photoelectric Smoke Detector Detection Circuits 1 & 2 Contact Type Heat Detectors DH-60 (21N) Duct Detectors Agent Release Solenoid Deluge Release Solenoid Remote Display Units Gemini II Control Panel Capacity (Amperage rating of Power Supply): 4 amp I Total System Current Demand: 0.91 am Total amps used in Standby: 0.10011 am Tot Syst.m Cu,rsnt Dsniand must not sxcs.d Control Panul C.paclty Total amps required for 60 Hours Standby: 6.0066 AH Total Amps required for 5 min. of alarm: 0.07583 AH Total Backup Battery Required: 6.08243 AH Total Backup Battery Provided 12 AH 20% Deraling Factoc 9.6 AH Total Backup Battery Reserved: 351757 AH Includes relays activated during pu-alarm conditions. WIRING END CONNECTION FOR THESE FUNCTIONS BY OTHERS I—INDICATES (1) PAIR 14 A6 THHN SOLID COPPER CONDUCTOR (TYPICAL) NOTIFICATION ALARM CIRCUIT NO, 1 3. 9K EOL 3, 9K EOL 3. 9K EOL I 3.9K EOL A-IND-1 ED E1-H 3, 9K ACTU- EOL fl io, I FM-200 SYSTEM CONTROL PANEL 25' (GEMINI II) PROTECTS 10' ANECHOIC CHAMBER 20' ALARM SIGNAL TO IRE ALARM CONTRO PANEL TROUBLE SIGNAL TO IRE ALARM CONTROL PANEL SIGNAL FOR IR HANDLER/DAMPER SHUTDOWN POINT TO POINT WIRING LAYOUT , NOSCAft CHAMBER DIMEN6ION5 VOWM= Lx W x ti = 16-2"x 16-2" x 13'-2 I/2 = 3039.G Cr FM-200 PROTECTED AREA -- i NOTE: p (.) PIPING ftNTRATION BEING SUFFUED BY OTHM. ANChOIC CHAMBER LPEOL SURFAC-MOUNTED PIPING - HT: II/?J I [RELA54 ABORT 5TA HORN 5TROBE L \ ] F bl EOL 5 FACE MOUNTED rJ E GEMINI II CONTROL F I 25 LE3.FM-200 CYLINDER REFLECTED CEILING PLAN. 5CALE: I/4'= I.0 Sierra Wireless 2290 Cosmos Ct. Reference Vct Ames Ames Feet Size Foot ACTU-1 24 0.2000000 0.2000000 20 14 0.0052 0.0210219 0.0876% Total Percentage Amps Conductor Voltage Drop Voltage Drop I Totals 0.200 20 0.02102 0.0876% I 31241059:23 AM Page 1 of I Sierra Wireless 2290 Cosmos Ct. A-IND-1 24 0 1030000 0 b30(0 10 14 : 0 0052 00054131 0.0226% Yui -. Percentage Amps Conductor Voltage Drop Voltage Drop 3124/059:24 AM Page lofi Sierra Wireless 2290 Cosmos Ct. P-A 24 0.0000550 0.O0005& 10 14 Ob05%i 0.0000029 0.0000% Total Percentage Amps Conductor Voltage Drop. Voltage Drop .0.00005, 31241059:25 AM Page 1 of I Sierra Wireless 2290 Cosmos Ct. • P-B • 24 0.0000550 bOOOO55p 25 14 0.0000072 0.0000% Total Percentage : • Arnps Conductor Voltage Drop Voltage Drop 31241059:25 AM Suppression System Abort EFFECTIVE FEBRUARY 1996 1-152 FEATURES UL Listed, File # S3743 Flush or Surface Mount Sized for Double Gang Box Large Yellow Push Button Switch One Normally Open Contact DESCRIPTION The KIDDE Abort Station features a large, easy-to-operate abort push button. The momentary type switch is very easy to see due to its highly visible yellow color. The abort station stainless steel faceplate is clearly labelled with operation procedures - eliminating indecision and hesitation. The Backbox .is painted with red enamel and comes equipped with four 1/2" knockouts. The pre-drilled and tapped mounting tabs allow for easy attachment of the abort station. TECHNICAL SPECIFICATIONS Electrical Ratings & Specifications: 1.1 amps © 120 VDC Ambient Temperature: 70°C (158°F) to -20°C (-4°F) Terminals: Captive screws and saddle clamps accept 14 awg to 20 awg wire Includes: Four 6-32 x 1/2" mounting screws ORDERING INFORMATION Diagrams with Dimensions S S PUSH/HOLD 4.5 Q SUPPRESSION SYSTEM ABORT KIDOE5 PIN Description Approx. Shipping Wt. 878752-01 Abort Station without Backbox 2 lbs. 878752-02 Abort Station with Backbox 3 lbs. 296105 Backbox 1 lb. This literature is provided for informational purposes Only. KIDDE-FENWAL, INC. assumes no responsibility for the products suitability for a particular application. This product must be properly applied to perform as described herein. It you need more information on this product, or if you have a question, contact KIDDE- FENWAL. INC.. Ashland, MA 01721. (508) 881-2000. 1-152 2/96 2.5M 01996 Kidde-Fenwal, Inc. Printed in U.S.A. CP KIMM. Fire Systems KIDDE-FENWAL, INC. 400 MAIN STREET, ASHLAND, MA 01721 TEL: (508) 881-2000 FAX: (508) 881-8920 Manual Stations Series Bi 0 & Bi 1 EFFECTIVE January 1997 84.05 FEATURES Exclusive KIDDE® Design Unique Field Labeling for either Fire Alarm or Suppression Applications Dual Action Operation Single Pole or Double Pole Keylock for Reset and Test• UL Listed and FM Approved cUL Listed for Canada ADA Compliant CSFM Listing (pending) MEA Approval (pending) Optional Weatherproof Box DESCRIPTION The Kidde B10 and Bli Manual Pull Stations are high quality, reliable non-coded alarm initiating devices based upon a proven design. They are con- structed of heavy die-cast aluminum for long life and reliability. These manual stations have the exclusive Kidde look, with gloss red paint with raised white let- tering, and black sides with a white trim border. The B10 station has a standard single pole single throw switch, while the Bil has a double pole single throw switch for local annunciation or remote signal- ing. Switches are gold plated for reliability when used in low current initiating circuits. These manual stations are designed for quick, effi- cient response by personnel in an emergency, while the standard double action PUSH/PULL levers pre- vent accidental operation. The keylock allows the unit to be easily reset and tested, and the stations are keyed to match the Kidde ScorpioTM, PEGAsysTM, and Orion TM control panels. Optional surface backboxes are available, which are painted red and sized to match the manual stations. The SGB-32S is UL Listed for indoor use, and the SGB-32C cast aluminum weatherproof box is UL Listed for outdoor use. The weatherproof box comes with a gasket kit which allows either the B10 or Bil to be mounted outdoors. B 1 or 0 1 shown with Fire Alarm Label Installed FIRE ALARM OR SUPPRESSION RELEASE LABELING The Kidde 1310 and Bli Manual Pull Stations have a unique labeling method which provides the installer the greatest amount of flexibility. Six labels are shipped with each station: FIRE ALARM FIRE SYSTEM RELEASE FM-200 RELEASE FE-13 RELEASE CO2 RELEASE HALON 1301 RELEASE These permanent, heavy-duty Lexan self-adhesive labels are die-cut with raised lettering. During instal- lation, the installer simply chooses the appropriate label, removes the protective backing, and places the label into the space on the top of the station. This flexibility allows installations to be customized for each customer, without the expense of having to carry extra inventory. OPERATION The dual action B10 and Bil manual stations are operated by simply pushing the PUSH bar inwards, allowing the PULL handle to be grasped in a one- handed motion. The handle is then pulled down as far as it will go. If the optional breakrod is installed, it would break at this point. The handle is now locked in place, and is easily visible from up to 50 feet away. The handle is reset by opening the sta- tion with the key, placing the handle in the normal upright position, and re-locking the station. SPECIFICATIONS B10 & Bil Manual Pull Stations Style: Double Action, non-coded. Dimensions: 4.75"H x 3.25W x 1 °D Contact: B10: Single Pole, Single Throw B1 1: Double Pole, Single Throw Contact rating: 1 amp @ 125VAC or 30VDC Gold plated contacts. Wiring: Terminal block connections with clamping plate for in & out wiring. Suitable for up to 12AWG wiring. Mounting: Mounts to a standard single gang box, or the SGB-32S or SGB-32C surface boxes. Two 6/32 screws ship with each unit. Keylock: Keyed to match Kidde ScorpioTM, PEGAsysTM, and OrionTM control panels. One key ships with each unit. Breakrod: Optional, order separately. Constructed of clear acrylic tubing. Visible from front of unit if broken. Temperature: -12F to 132F (-25C to 56C) SGB-32S Interior Surface Backbox Dimensions: 4.75"H x 3.25"W x 2.25"D Construction: Steel sheet metal. Conduit Two knockouts for 1/2" conduit connectors, one on top and bottom. Mounting: B10 or 611 mounts to the box with (4) 8/32 screws, which ship with each box. Range of labels supplied with BIO.and B1 SGB-32C Weatherproof Surface Backbox Dimensions: 4.75"H x 3.25W x 2.250 Construction: Cast aluminum. Conduit One threaded opening for 1/2" conduit connector. Mounting: 610 or Bil mounts to the box with (4) 8/32 screws and a foam gasket, which ship with each box. ORDERING INFORMATION Part Number Description Shipping Weight 84-100007-001 B10 Pull Station SPST Includes six labels. 1.2 lb 84-100007-002 Bli Pull Station DPST Includes six labels. 1.3 lb 84-100009-001 SGB-32S Indoor Box .8 lb 84-100009-002 SGB-32C Outdoor Box 84-100008-002 Pkg. of (12) Breakrods Must order separately. >25 lb 06-118013-001 Spare Key for 610/611 >25 lb DIMENSIONS (shown with Fire System Release Label installed) SEW This literature is provided for informational purposes only. KtDDE-FENWAL, INC. assumes no responsibility for the pmducfs suitability for a particular application. The product must be properly applied to perform as described herein. If you need more information on this product, or if you have a question, contact Kidde- FENWAL INC.. Ashland, MA 01721. (508) 881.2000. 8405 2197 5M 01997 KIDDE-FENWAL INC. Printed in U.S.A. CP M H3MX9 Fire Systems KIDDE-FENWAL, INC. 400 MAIN STREET ASHLAND, MA 01721 (508) 881.2000 FAX: (508) 881-8920 Series MT Multitone Horns & . . Effective: March 2002 Mauro R__I.t.I____ uI_____ ___U I - FEATURES Approvals include: UL 1971 & UL 464. Factory Mutual (FM), California State Fire Marshal (CSFM) and New York City (MEA) Pending. Designed to meet or exceed ADA/NFPA/UFC/ANSI Standards and Accessibility Guidelines. Meets OSHA 29 Part 1910, 165. One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels. Audible and strobe can operate from a single signaling circuit with any of the (8) eight audible signals. Code-3 Horn and Tone meet ANSI!NFPA temporal pattern for standard emergency evacuation signaling. MT Strobe models available with 15/75 and 75 candela ratings for independent or single input activations.. Strobe markings for fire and suppression applications. Wide listed voltage range, filtered (DC) and FWR. Polarized inputs for compatibility with standard reverse polarity type supervision of circuit wiring by an alarm panel. Weatherproof Models available. Low cost installation via standard electrical boxes. Attractive flush or surface mounting options. No additional trimplate required for flush mounting. IN and OUT wiring terminations that accept two #12 to #18 AWG wires at each terminal. DESCRIPTION Fenwal Series MT and MT Strobe Multitone electronic sig- nals offer a choice of (8) nationally and internationally rec- ognized alerting sounds: Horn, Bell, March Time Horn, Code-3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. Our Code-3 horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe Signals, one alarm appliance meets most of your signaling heeds. The MT Strobes are designed for ADA applications with maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72(1999),ANSI 117. 1, UFC (2000) and UL Standard 1971 as well as meeting ADA requirements concerning photo- sensitive epilepsy. Series MTWP Horn-Strobe Each MT and MT Strobe appliance has two user selective sound output levels: STANDARD dBA and HIGH dBA. The MT-12114 provides dual voltage capability in one unit, 12 Vdc or 24 Vdc operation, filtered or FWR. The MT Strobe Electronic Signals operate with 24 Vdc and may be used with filtered or unfiltered (full-wave-rectified) input voltages. Separate input terminals are available and shunt wires are provided to enable both tone and strobe to operate simul- taneously from a single input. The Multitone Strobe Signals are UL Listed for indoor wall mount applications, under Standard 1971 for Devices for the Hearing Impaired and under Standard 464 for Audible Signal Appliances. MT Strobe models are listed for indoor use with a tenperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ±2%. The MT-12/24 and MTWP models for outdoor use, are Listed for -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95%. The strobe devices use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® (or equivalent) lens to pro- vide maximum reliability for effective visible signaling. Strobe lens markings available for "Fire". and "Agent" labeled ap- plications. The Series MT Signals have IN and OUT wiring termina- tions that accept two #12 to #18 AWG wires at each termi- nal. Inputs are polarized for compatibility with standard reverse polarity type supervision. Table 1. Alarm Tones GENERAL NOTES Tone Alarm Tones Pattern Description Horn Broadband Horn (Continuous) Bell 1560 Hz Modulated (0.07 sec. ON/Repeat) March Time Horn Horn (025 sec. ON/0.25 sec. OFF/Repeat) Code-3 Horn Horn (ANSI S3.41 Temporal Pattern) Code-3 Tone 500 Hz (ANSI S3.41 Temporal Pattern) Slow Whoop . 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) Siren 600-1200 HZ SWEEP (1.0 sec. ON/Repeat) Hi/Lo 1000/800 (0.25-sec. ON/Alternate) Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range." Note that NFPA-72 (1999) specifies, a flash rate of 1' to 2 flashes per second and ADA Guidelines specifies a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Multi- ton Strobe intensity based on UL 1971. The MT Audible is UL 464 Listed. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change. UL used the terminology "Listed Voltage Range." SPECIFICATIONS Table 2. dBA and Current Ratings for Series MT Audible Portion Tone . Average Current Ratings (Amps) ' dBA Reverberant Ratings per UL 464 dBA Anechoic Ratings @12 and 24Vdc @24Vdc @12Vdc tg24Vdc @12Vde HI STD HI STD Hi STD HI STD HI STD Horn 0.024 0.095 0.019 92 87 90 77 99 93 Beg 1 0.019 0.012 0.030 0.010 86 80 85 69* 92 87 March Time Horn 0.038 0.024 0.095 0.019 89 84 89 74* 99 93 Code-3 Horn 0.038 0.024 0.095 0019 88 83 88 73* 99 93 Code-3 Tone 0.027 0.016 0.057 0.014 ' 85 , 80 84 70* 95 90 Slow Whoop 0.047 0.025 0.095 0.024 90 89 89 75 99 94 Siren 0.034 0.022 0.078 0.019 89 84 89 75 98 93 HIILO 0.020 0.013 0.042 0.011 86 81 86 71* . 93 88 (see below fbrt note) A WARNING 12V Multitone strobe models set on standard dBA do not meet the 75 dBA minimum UL reverberant sound level required for public mode fire protection service (noted by * in Table 2). Models with settings which produce less than 75 dBA may not be heard. This setting is acceptable only for general signaling (non-fire alarm) use. Use the "high" dBA for public Mode Service. , Table 3. Current Ratings for Series MT Strobe Portion 24 We Voltage Range Average Current Ratings (Amps) MT-241575W MT-2475W MTWP2475W 16.0 Vdc .094 .205 .150 24.0 Vdc .102 33.0 Vdc .053 .109 .086 WIRING DIAGRAMS MT SIGNAL FROM PRECEDING TO NEXT + F APPLIANCE APPLIANCE. SMIOSM OR EOLR OR FACP - SIGNAL AUDIBLE SIGNAL AND STROBE OPERATE INDEPENDENTLY FROM PRECEDING + + TO NEXT AUDIBLE OR - APPLIANCE FACP OR EOLR FROM PRECEDING ________________________ TO NEXT APPLIANCE. __________________ SF&VSM STROBE OR EOLR - :Jl.____u OR FACP + H0 H + H STROBE AUDIBLE AUDIBLE SIGNAL AND STROBE OPERATE IN UNISON, RED AND BLACK SHUNT-WIRES ARE SUPPLIED. FROM RED PRECEDING + + TONEX1 - APPLIANCE. - I12J B OR EOLR APPLIANCE OR FACP HI+ H STROBE AUDIBLE INSTALLATION NOTES If the strobe and audible operate on the same circuit, add the strobe current from Table 3 to the audible cur- rent from Table 2. For Peak and Inrush current across the listed voltage range, refer to Installation Instructions. The average current indicated is per actual Production Testing at listed Vdc. For rated average and Peak cur- rent across the UL listed voltage range for both filtered DC and unfiltered VRMS, see Installation Instructions. A WARNING Failure to comply with the installation instruction sheets could result in improper installation, application, and/or operation of these products in an emergency situation, which could result in property damage and serious injury or death. 3. Contact Fenwal forinstallation Instructions" sheets on these products. These materials contain important in- formation that should be read prior to specifying or in- stalling these products, including: Total current required by all devices connected to system primary and secondary power sources. Fuse ratings on signaling circuits to handle maxi- mum inrush or peak currents from all devices on those circuits. Composite flash rate from multiple strobes within a person's field of view. Installation in office areas and other specification and installation issues. Use strobes only on circuits with continuously ap- plied operating voltage Do not use Strobes on coded or interrupted circuits in which the applied voltage is cycled on and off, as the strobe may not flash. The voltage applied to these products must be within their rated input voltage range. Conductor size (AWG), length and ampacity should be taken into consideration prior to design and in- stallation of these products, particularly in retrofit installations. 4. Fenwal notification appliances must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installa- tion instructions at the time of installation and at least twice a year or more often and in accordance with lo- cal, state and federal codes, regulations and laws. Specification, application, installation, operation, main- tenance and testing must be. performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Elec- trical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes in- cluding, but not limited to, all appendices and amend- ments and the requirements of the local authority having jurisdiction (AHJ). ARCHITECTS AND ENGINEERS SPECIFICATIONS *he notification appliance shall be a Fenwal MT Series au- lible/visual device or equivalent. Notification appliance shall ue electronic and use solid state components. Electrome- chanical alternatives are not approved. Each electronic sig- nal shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN AND HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. The Multitone Audible appliance shall be UL Listed under Standard 464 for Au- dible Signal Appliances. The audible and the strobe shall be able. to operate from a single notification circuit while producing any of these tones. The device shall provide two output sound levels: STANDARD and HIGH dBA. The HIGH dBA setting shall provide a minimum 5 dBA increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 101 dBA minimum for MT and 92 dBA minimum for MT Strobes, at nominal voltage. Operating voltages shall be 24 Vdc using filtered power or unfiltered power supply (full- wave-rectified). All models shall have provisions for stan- dard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens or quivalent with solid state circuitry. Strobe shall produce a ash rate of one (1) flash per second minimum over the voltage range. .The strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for 15/75 or 75 candela. The 15/75 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Fenwal SM and/or DSM Sync Modules. The strobes shall -not drift out of synchroni- zation at any time during operation. If the module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. All Listed strobe appliances shall incorporate low tempera- ture compensation to insure the lowest possible current con- sumption. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances may be installed indoors and surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installa- Fenwal is a registered trademark of Kidde-Fenwal Inc. Lexan is a registered trademark of the General Electric Company FENWAL Protection Systems KIDDE-FENWAL, INC. 400 MAIN STREET, ASHLAND. MA 01721 TEL: (508)881-2000 FAX: (508) 881-8920 www.fsnwalfire.com tion is completed. The appliance shall be finished in a tex- tured red color. The audible device may be installed indoors or outdoors with the proper backbox. For weatherproof applications where specifications require 75 cd at -31 OF (-35°C) and full temperature range of -31°F to 150°F, the Fenwal Model. MTWP-2475W FR shall be used. ORDERING INFORMATION Model Number Part Number Input Voltage Rated Candela Strobe Label Mounting Options MT.12024-11 75.000010-001 12/24 - - B,H,I,J,K ffT.241575W-FR 75-000015-001 24 15 (75 on AXIS) FIRE B,H,I,J.K MT-241575W-AR 75-000015-002 24 15(75onAXIS) AGENT B,HAJ,K MT-2475-FR 75-000016-001 24 75 FIRE B,H,W,K MT-2475-AR 75.000016-002 24 75 AGENT B,H,I,J,K MIWP-2475W-FR 75-000017-001 24 75 FIRE H Notes: MT-1 2/24 Audible can be used with Fenwal's RSSP Multi-Candela for applications requiring 15,30,75, 110 cd Wall Strobes. S MTWP-2475W is weatherproof and rated for 75 cd @ -31°F (-35°C). SM Sync Modules are rated for 3.0 amperes at 12/24 Vdc; DSM Dual Circuit Modules are rated for 3.0 am- peres per circuit. Maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet 75- 12. Use MT-241575W when 15 cd is specified. 15/75 is UL Listed for 15 cd with 75 cd on AXIS. MOUNTING OPTIONS Model Number Part Number Mounting Options DBB-R 75-000000-009 A ISP-R 75-000000-002 B WBB-R 75-000000-008 E lOB-R 75-000000-001 H RP-R 75-000000-003 J For complets installation options, refer to the Alarm Sig- nals Installation Data Sheet 75-008.A. This literature is provided for Informational purposes only. KIDDE-FENWAL,INC. assumes no responsibility for the products suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question. Contact KIDDE-FENWAL INC.. Ashland, MA 01721. Telephone: (508) 881-2000 75-001 03/02 02002 Kidde-Fenwal, Inc. Printed in U.S.A. CID Photoelectric Smoke Detect Ors PSD7155 AND 7156 Series Data Sheet 71.55.2 FEATURES UL 268 AND 268A Listed FM Approved CSFM Listed #7272-1076-117 MEA Accepted # 346-92-E ULC Listed # 3810 D19 Inpiace Sensitivity measurement in percent (%) per foot obscuration Optional thermistor heat detector Remote functional test capability Local functional test capability (magnet test) Wide range input voltage 10.2 to 36.8 VDC Low Profile Appearance SMT - Surface mount technology Electrically and Mechanically compatible with all Fenwal. detectors and bases 3-year warranty Optional 2- and 4-wire relay bases Universal relay modules Nonpolarized High air velocity rating 2- and 4-wire, low-current design Interchangeable bases Flashing LED for visual supervision Locking feature for tamper resistance EMI!RFI resistant Improved fine mesh Insect screen Nominal sensitivity 3.25°/dft. DESCRIPTION Models PSD 7155 and 7156 series photoelectronic Smoke de- tectors respond to a broad spectrum of both flaming and smol- dering fire conditions. They incorporate state-of-the-art, solid- state, low-voltage circuitry featuring SMT (Surface Mount Tech- nology) and are designed for 2-wire and 4-wire installation with the proper base. The detectors are designed for open area protection (UL Standard 268) and for duct applications (UL Stan- dard 268A). They may be installed in fire protection systems and systems intended for releasing device service with com- mercially available fire suppression or detection control units, provided compatibility has been established. Model PSD 7156 includes a 135°F thermistor heat detector. These models operate over a 10.2 to 36.8 VDC range (2WB base only, 24V nominal) with compatible control units. EMI/ RFI noise immunity up to 20 volts/meter assures virtual elimi- nation of false alarms from electrical interference. Effective: September 1996. A 0-300 fpm and the 7155P is rated for 0-4000 fpm open area detection. Sensitivity ranges can be measured in place using a commercially available voltmeter and a special Fenwal meter (ST-001) that allows direct % per foot obscuration measure- ment. Readings found to be within specified limits are accept- able for normal field applications. Model PSD 7156 includes a thermistor heat detector with 135°F set point. Operation of the thermistor detector is independent of smoke detector circuitry. Functional testing is accomplished by means of a magnet which causes an alarm condition. This magnet test meets the require- ment of the U.L. Sensitivity Test Feature. Under alarm condi- tion, the pulsing LED will switch to a steady red illumination. Base installation is both simple and fast because of screw- type connections. The detector is fitted to the base by a twist- to-lock action. A removable locking tab secures the head to base to provide a high degree of vandal resistance. An extra fine mesh insect screen protecting the chamber area reduces potential nuisance alarms. Photoelectric detectors may be interchanged with Fenwal ion- ization detectors when using multifunction base configurations. Optional bases are shown in Table Ill. High signal-to-noise ratio permits a significant reduction in light ELECTRICAL SPECIFICATIONS baffling, thereby improving smoke entry characteristics while reducing nuisance alarms. The Fenwal photoelectric smoke These detectors are designed for operation with control units detectors are, therefore, ideal for fire alarm and and suppres- and releasing devices having specific voltage and current char- sion systems service. acteristics that are compatible with the detector circuitry. The PSD 7155 and 7156 are set at a nominal sensitivity of 3.25% information provided under the headings CONTROL UNIT and per foot smoke obscuration. The PSD 7155P has a nominal Table Ii are intended to assist in proper application of the de- sensitivity of 1.45% per foot. The 7155 and 7156 are rated for tector in a system. Reference the UL compatibility listing for other panels listed. PHOTOELECTRIC SMOKE DETECTOR MODEL 7155 PIN 71-550000-001 10.2 to 36.8 VDC 16.8 to 36.8 VDC 50% of DC input 55pA (typical) 100iA peak at 24 VDC 0.1 mA max. lOOmAmax. LED Internal 32°F (0°C) to 100°F (38°C) as per U1268 0 to 93% (noncondensing) 3V (typical) mm. 1.0 sec. max. 20 sec. max. 5.5V (typical) OR white 2.8202. (80 g) w/o base UL (SW. 268) FM Approved CSFM Listed #7272-0176-117 MEA Accepted #346-92-E Contact Kidde-Fenwal for information on other approvals 1.47- 3.75%/ft. P55FE1 35mm, 1.38" 99mm, 3.90" (without base) PHOTO WHEAT SMOKE DETECTOR MODEL 7156 PIN 71.560000.001 102 to 36.8 VDC 16.8 to 36.8 VDC 50% of DC input 55pA (typical) 1O0iA peak peak at 24 VDC 0.1 mA max. 100 mA max. LED internal 32°F (0°C) to 100°F (38°C) as per UL268 0 to 93% (noncOndensing) 3V (typical) mm. 1.0 sec. max. 20 sec. max. 5.5V (typical) Off white 2.82 oz. (80 g) w/o base UL (Std. 268) FM Approved CSFM Listed #7272-0176-117 MEA Accepted #346-92-E Contact Kidde-Fenwal for Information on other approvals 1.47- 3.75%/ft. P56FEI 48mm, 1.89" 99mm, 3.94" (without base) UJI Standby Maximum ripple Standby Current Start-up current Alarm current Alarm Indicator Normal operating temperature range Operating relative humidity range Reset voltage Reset time Start-up time Alarm voltage (detector voltage in alarm condition) Finish Weight Approvals UL sensitivity Window Compatibility ID DIMENSIONS Height Diameter PHOTOELECTRIC SMOKE DETECTOR MODEL 7155P PIN 71.550000-002 10.2 to 36.8 VDC 16.8 to 36.8 VDC 50% of DC input 55iiA (typical) IOOMA peak 0.1 mA max. 100 mA max. LED internal 32°F (0°C) to 100°F (38°C) as per UL268 0 to 93% (noncondensing) 3V (typical) mm. 1.0 sec. max. 20 sec. max. 5.5V (typical) ON white 2.82 02. (80 g) w/o base UL (Std. 288A) FM Approved CSFM Listed #7272-0176-117 MEAAccepted #348-92-E Contact Kidde-Fenwal for information on other approvals .83 - 2tL P55FEI 35mm, 1.38° 99mm, 3.90° (without base) PHOTOELECTRIC SMOKE DETECTOR MODEL 7155C PIN 71-550000.011 102 to 36.8 VDC 16.8 to 36.8 VDC 50% of DC input. 5511A (typical) lOOjiA peak 0.1 mA max. 100 mA max. LED internal 32°F (0°C) to 100°F (38°C) as per UL268 0 to 93% (noncondensing) 3V (typical) mm. 1.0 sec. max. 20 sec. max. 5.5V (typical) Off white 2.82 oz. (80 g) w/o base ULC(Std. 3810 D19) Contact Kidde-Fenwal for Information on other approvals 1.47- 3.75%/ft. P55FE1 35mm, 1.38° 99mm, 3.90° (without base) PHOTOELECTRIC SMOKE DETECTOR MODEL 7156C PIN 71460000-011 102 to 36.8 VDC 16.8 to 36.8 VDC 50% of DC input 55iA (typical) 100iA peak 0.1 mA max. 100 mA max. LED internal 32°F (0°C) to 100°F (38°C) as per UI268 0 to 93% (noncondensing) 3V (typical) mm. 1.0 sec. max. 20 sec. max. 5.5V (typical) Off white 2.82 oz. (80 g) w/o base ULC (Std. 3810 D19) Contact Kidde-Fenwal for information on other approvals I dI 3.75%/ft. I PS6FE1 48mm, 1.89° 99mm, 3.94° (without base) ENVIRONMENTAL SPECIFICATIONS TECHNICAL SPECIFICATIONS EMI immunity: 20-volts/meter to 1GHZ 10 volts/meter from 1GHZ to 2GHZ Spikes to 2400 volts or 1 joule Smooth ceiling spacing: 30 ft. center (900 sq. ft.) max. Storage temperature: -20° to .180°F (- 290 to 82°C) Alarm Ratings: Current: 10 to lOOmA max. Alarm currents below 19mA result in diminished brilliance of LED alarm indicator and precludes the use of the au- xiliary relay option. Optional Thermistor Head Detector For releasing service applications, thermistor actuation 31ectrica11y shorts the detector circuit and may be used to release suppressant. Models PSD 715X have been tested by Underwriters Laborato- ries for environmental stability. Some of the basic conditions that must be met for compliance are listed below and are presented to help serve as application guidelines: 1. Temperature: 320 to 120°F - Installation in ambient above 120°F is not recommended. UL Rated temperature range is 320 to 100°F. 2. Corrosive Atmosphere: An atmosphere containing 0.1% hydrogen sulfide by vol- ume in air saturated with water vapor at room tempera- ture for 10 days. An atmosphere containing 1% carbon dioxide by volume and 0.5% sulphur dioxide by volume in air saturated with water vapor at room temperature for 10 days. In all cases, a Fenwal technical representative should be con- sulted if the detectors are to be operated under adverse environ- mental conditions. 3. Air Velocity: 0- 300 ftimin. for open area detection (7155, 7156) 0- 4000 ft./min. for open area protection (7155P) 500 -4000 ft./min. for duct applications (7155P) 2 CONTROL UNIT These detectors are compatible with the Fenwal control units and interface modules listed below. Consult Fenwal for.informa- tion regarding other manufacturer's control units for which com- patibility has been established. BASE CONTROL UNIT SELECTION Control units in Table II can be used with the detector base op- tions in Table lii. TABLE II MAXIMUM COMPATIBILITY NUMBER OF CONTROL UNIT IDENTIFIER DETECTORS MODEL NUMBER NUMBER PER LOOP 2210 C10FE1 40 2212 C12FE1 40 2220 C20FE1 5 3210 ZDM01, ZDMD01, 25 VZM01 2320 C30FE1 15 Contact Fenwal for information on compatibility for other manufactur-ers' panels or refer to the compatibility cross reference list (Docu- ment # 70.63) BASE Various base options are available to provide auxiliary relay and/ or remote indication and remote test feature. MODEL Auxiliary Relay: 2WRB 2-wire SPOT 1A @30 VDC. 0.5A @ 125 VAC 4WRB 4-wire SPDT 2A @ 30 VDC 1A@125VAC_ SPACING (OPEN AREA LOCATION) The PSD715X Series detectors are intended for use on 30 foot centers, smooth ceilings up to 15 feet high with mini- mum air circulation. Resultant 900 square foot spacing may be used as a reasonable guide for comparable applications. Where special conditions exist (ceiling obstruction, high air exchange rates, etc.), reduced square footage spacing must be used to achieve adequate protection. Computer rooms and other such installations may require spacing with a maximum of 200 square feet due to high air exchange rates. For additional information, consult National Fire Protection Association Standard .2E and the Fenwal Automatic Fire Detector Application Engineering Manual. SPECIAL APPLICATIONS For further assistance in the application of the PSD715X Series detectors, consult your Fenwal technical representa- tive. DETECTOR BASE OPTIONS TABLE Ill PART COMPATIBILITY NUMBER! IDENTIFIER MODEL NUMBER DESCRIPTION 70-501000-001 FE51A Connects to 2-wire 2 Wire detection circuit via (ULC-011). screw terminals 70-501000-002 FE52A Same as above plus 2 WRLT provision for remote LED (ULC-0.12) indicator and remote functional test. Observe polarity when using remote test feature. See Fig. 3. Min. alarm current: 15mA, 24 VDC. 70-501000-005 FE55A Connects to 2-wire 2 WRB detection circuit via (ULC-015) pigtail leads. Equipped with SPDT supplementary relay. Mm. alarm current: 19mA, 24 VDC. Remote LED and test capable. 70-501000-101 N/A Connects to 4-wire 4 WRB detection circuit via (ULC-111) pigtail leads. Equipped with SPDT supplementary relay. Mm. alarm current: 35mA, 24 VDC. 70-500000-004 N/A 2-wire relay module 2 WRM component of 70-501000-005 above. 70-50000Q-102 N/A 4-wire relay module 4 WRM component of 70-501000-101 above. 70-501000-003 MAFE1 Mechanical retrofit MA-001 adapter allows PSD 7155 and 7156 to physically connect to all Fenwal Series 70 (-001) bases. TYPICAL WIRING DIAGRAMS Figures 1,2,3, and 4 are typical wiring diagrams of 2-wire detector system, and Fig. 5 is a wiring diagram of 4-wire detector system. FIRST DETECTOR BASE LAST DETECTOR BASE TO CONTROL PANEL LINEINITIATING :O]ENDOF DEVICE CIRCUIT Fig. 1 Using 2-Wire Base (Less Options) P/N 70-501000-001 3 FIRST DETECTOR BASE LAST DETECTOR BASE 700 PANE INrrIi cIRCI END OF LINE DEVICE REMOTE LED REMOTE LED Fig. 2 Using 2WRLT Base with Remote Indicator Option P/N 70-501000-002 Fig. 3 Using 2WRLT Base with Remote Indicator and Remote Test Switch Options P/N 70-501000-002 FIRST DETECTOR BASE AUX. RELAY RA-914 CONTACTS RA-914 REMOTE LED/ FORM C REMOTE LEOJ TEST SWITCI( -' TEST SWITCI{ 1 ()---r, E HIc 4LV\\ INITIATING L -9jj Ja)EOj L - - CIRCUIT OF F DRY WIRED. CONTROL PANEL BlACK 00 NOT REMOVE L ----------41-BLACJ C-)-- LAST DETECTOR BASE AUX. RELAY CONTACTS FORM C IBLACK OF END .r LJNnlEFACtORY WIRED DEVICE NOT REMOVk I I I L------------ Fig. 4 Using 2WRB Base with Relay Module P/N 71-501000-005 Note: 1. All relays shown in normal position (Power-On). FIRST DETECTOR BASE LAST DETECTOR BASE AUX. RELAY AUX. RELAY CONTACTS RA-914 CONTACTS FORM C REMOW I rn/ FORM C A.- - NOTES 1.. To insure proper installation of the detector head to the base, be sure wires are properly dressed at installation: Position all wires flat against the base. Take up all slack in the outlet box. Route-wires away from the connector terminals. Remove jumper between terminals 6 and 7 before installing detector head. CAUTION - Do not use looped wire under terminal 2. Break wire runt to provide supervision of connections. Observe uniform polarity of detector circuit connections when using direct return wire for LED connections. When utilizing common retum.for remote LED indica- tors, test detector circuit for supervisory continuity. Removing detector circuit terminal connections must ml date control panel trouble sequence. Observe polarity (Fig. 3 and 4) when using remote test option. When detectors employ relay or remote indicator optior all detectors on a loop must be equipped with this optic and all must be interconnected to perform a common function. 2-wire detectors must be UL Listed compatible with cor trol panels. NOTES (4WRB Base) All relays shown in normal position (power ON standby). Alarm current @ 24VDC = 53mA with remote LED. Auxiliary contacts rated 2A, 24VDC for Canadian applicati The end-of-line supervisory relay utilized shall be listed e of.-line power supervisory relay rated for the DC supply v age used. The Fenwal end-of-line. relay (P/N 29-116788-0 is rated for 24 VDC operation. The end-of-line supervisory device shall be compatible the control unit used. INSTALLATION BASE Detector bases are directly mounted on the electrical junc- tion boxes (3, 3.5, and 4 inch octagonal; 3 inch round; 4 inch square) without any type of mechanical adaptor required. GENERAL Route all leads outward from the junction box. For bases equipped with pigtail leads, make all pigtail cc nections using approved connection means. Be sure to in late any unused pigtails and the end-of-line resistor. Refer Typical Wiring Diagrams for color code and interconnect c tails. Position wires and connectors in the junction box so as leave the center of the box as clear as possible. Dress wires terminating at detector base terminals. After all detector bases are installed, including the end- line relay and resistor, check loop continuity. To make I continuity check, jumper must be installed. An open circ condition exists unless jumper or detector is installed in base (See Fig. 6). If loop continuity is acceptable, remove the jumper wire o necting base terminals 6 and 7 at each detector location. Proceed to detector head installation. FIRST DETECTOR BASE LAST DETECTOR BASE TO CONTROL IEND PANEL II OF INIllATiNG 'I' LINE CIRCUIT - I- i - I DEVICE REMOTE LEO/ :911 - - aoREMOTELEW RA-914 1 RA-1114 TESTSWFICH SWITCH 24 VOC -r ••tIJ 4WRM 3 FAC CRY WIRED. DO NOT REMOVE (-.)--------------.. . . TO INITIATING I--------J II L--CIRCUIT OF -----II-------------- CONTROL PNAEL1- --------- ii----------------.11--------- Fig. 5. Using 4WRB 4-Wire Base with Relay Module PIN 70-501000-101 4 BODY 5. JUMPER WIRE (remove before installation CONTACT ARM of detector head) CONTACT SPRING 6. TERMINAL SCREW TERMINAL PLATE 7. Ri: RESISTOR (with cover) Fig.6 To check loop continuity without detector head in place, install jumper wire by inserting ends into holes in terminals 6 and 7. REMOVE JUMPER BEFORE INSTALLING DETECTOR HEAD DETECTOR HEAD INSTALLATION WARNING TO PREVENT DETECTOR CONTAMINATION AND SUBSEQUENT WARRANTY CANCELLATION, SMOKE DETECTORS MUST RE- MAIN COVERED UNTIL AREA IS CLEAN AND DUST FREE. 1. Push the detector head into the base and rotate until the de- tector key tabs drop into place. Rotate clockwise about 1/2" travel to engage electrical connections. The head will auto- matically lock into place due to locking feature included on the base. 2 To remove detector, insert a maximum 1/4" wide screwdriver blade into the lock access slot and push with moderate pres- sure while rotating the detector head counterclockwise. Once rotation starts, remove the screwdriver. Continue to rotate the detector head counterclockwise until a stop is reached. Then pull downward to disengage from base. (See Figure 713) NOTE: The locking feature may be removed by breaking away the locking tab. See Fig. 7A.. LOCKING FEATURE These detector bases also include a locking feature that pre- vents removal of the detector without use of a tool. Refer to "De- tector Head Installation" for details. Use sineM bladed saswdriver todcmgtab Fig. 7A Fig. 7B Eliminating locking feature. Removing detector head from Break plastic tab by twisting base. toward center of base. Testing: General The following test shall be performed upon installation of the de- tector and once a year thereafter as stated in NFPA-72 (1993). All alarm signal devices, releasing devices, and extinguishing sys- tems should be disengaged while the test is being performed and reengaged at the conclusion of testing. After powering the detector head for approximately 1 minute, check to see that the alarm indicator LED flashes. Failure to flash indicates a nonfunctioning detector or faulty wiring. Re- check wiring and replace detector head it necessary. Position a test magnet* against the detector housing marked "TEST '(see Fig. 7B) for at least 15 seconds. The detector should alarm as indicated by steady illumination of the alarm indicator. To return each detector to normal operation, reset the control unit. Fenwal P/N 06-117883-001 or equal. *Use extreme caution when using magnet in EDP Facilities. To be safe, notify EDP management of intent to use magnet in their facilities. The long axis of the magnet should be positioned against the side of the detector housing marked "TEST" (See Fig. 7B). OR Allow smoke to enter the detector sensing chamber and ob- serve the red alarm indicator. When sufficient smoke has en- tered the chamber, an alarm will be indicated by continuous illumination of the LED. Reset each detector and/or control unit after it alarms before attempting to test additional detectors in the same zone. Failure to alarm in tests 2 or 3 indicated a defective detector requir- ing service. SENSITIVITY METERING TEST To conduct sensitivity testing for the PSD7155 and 7156, you will need the following test equipment. 1 megohm (minimum) input impedance voltmeter (FLUKE, Model No. 8024 or equivalent) Sensitivity tester Model ST-001 P/N 70-500000-002 Disengage alarm signal devices, releasing devices, and extin- guishing systems while test is being performed. Remove the detector head from the base as described under Detector Head Installation. Note the % per foot obscuration range marked on the detector label Under nominal sensitivity. Reinstall the detector head to the base. Allow 1 minute for stabi- lization. The alarm indicator should flash approximately once every 4 seconds. No flash indicates a nonfunctioning detector or faulty wiring. Steady illumination indicates an alarm state. Follow the detailed operating and sensitivity measurement in- structions provided with the Fenwal Sensitivity Tester (ST-001) P/N 70-500000-002. This sensitivity tester will perform the con- version to % per foot obscuration. Ref. Fig. 8. Sensitivity readings outside the given ranges indicate a shift in sensitivity and need for corrective action. a. Clean the detector as outlined under MAINTENANCE and repeat Steps 2 through 5. p 5 b. If readings are still out of the allowable range, replace the-detector. Except in cases of suspected terminal or cable problems. 7. After all the tests are complete, be certain that complete system is returned to normal. Fig. 8 General Equipment Connection Notes: 1) Digital voltmeter not supplied. 2) For more information, see instructions supplied with Sensitivity Tester. Data Sheet No. 70.50.A. Note: Detector sensitivity shall be checked within one year of installatior and every alternative year thereafter as stated in NFPA 72, dated 1993 MAINTENANCE The recommended requirement for detector maintenance consists of an annual cleaning of dust from the detector head by using the suction of a vacuum cleaner. Cleaning programs should be geared to the individual environ- ment in conformance with NFPA 72E Standard. CAUTION: DO NOT ATTEMPT DISASSEMBLY OF THE FACTORY SEALED SMOKE DETECTOR. THIS ASSEMLY IS SEALED FOR YOUR PROTECTION AND IS NOT INTENDED TO BE OPENED FOR SER- VICING. OPENING OF THE DETECTOR WILL VOID THE WARRENTY. Perform the Sensitivity Metering Test as outlined in this document. Confirm that the sensitivity readings are within specified limits on detector label. If sensitivity readings are out of limits specified-on detec- tor label, contact the factory customer service depart- ment for details concerning the detector EXCHANGE PROGRAM. The detector EXCHANGE PROGRAM offers the customer new product of the latest design as direct replacement for existirig detectors. The EXCHANGE PROGRAM is available to all end users for a nominal fee, regardless of the age of the detector. SPARE PARTS None. Unit is factory repairable only. No field repair should be attempted. ARCHITECT/ENGINEER SPECIFICATIONS The contractor shall furnish and install photoelectric smoke detectors, Fenwal Series PSD 7155 or 7156 where indicated on the plans. The-combination detector head and twist-lock base shall be UL Listed compatible with a UL Listed tire alarm control unit. PSD 715X series photoelectric detectors and CPD 705X series ionization detectors shall share an interchangable base. The Fenwal smoke detector shall have a flashing status indicating LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant security locking feature shall be used in those areas as indicated on the drawings.The locking feature shall be field removable when not required. It shall be possible to measure the sensitivity level of the detector without removal from the base. Measurement shall be accomplished with a commercially available volt- meter and a Fenwal Sensitivity Tester (ST-001) allowing direct measurement in percent per foot obscuration. It shall also be possible to perform a functional test of the detector without the need for generating smoke. The test method must simulate effects of products of combustion in the optical chamber to ensure testing of all detector cir- cuits. This test can be performed locally and/or remotely. By using a furnished wire jumper, it shall be possible to check circuit loop continuity prior to installing the detector head. The detector shall be listed and approved for wall and ceiling mounting. Models PSD 7155 and 7156 shall operate over an input voltage range from 10.2 to 36.8VDC. Voltage and RF transient suppression techniques to with- stand up 1020 volt/meter to be employed to minimize susceptibility to false alarms. The smoke detector may contain an optional 135°F ther- mistor temperature, self-restoring heat detector. Actuation of this device shall activate an alarm and function inde- pendent of the smoke detector electronic circuit. Supplementary SPDT relays, remote test, and/or remote LED alarm indicators may be installed where indicated. 0 I This literature is provided for Informational purposes o* KIDDE-FENWAL, INC. I I assumes no responsibility for the products suitability for a particular application. The I product must be properly applied to perform as described herein. E.I1IqAII.. j If you need more information on this product, or if you have a question. contact KIDDE. I KIDDE-FENWAL. INC. FENWAL, INC., Ashland, MA 01721. (508) 881.2000. I 400 MAIN STREET ASHLAND, MA 01721 (508) 881-2000 FAX: (508) 881-8920 71.55.2 5/99 5M 01995 KIDDE-FENWAL, INC. Printed in U.S.A. CP Protection Systems CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1076:160 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Kidde-Fenwal, Inc., 400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 *FAX (508) 881-1773 DESIGN: Model GEMINI II AND FENWAL 3220 fire alarm control units. Power limited, automatic, manual, noncoded, local, central station, waterfiow and sprinkler supervisory service. Also suitable for releasing device service and deluge or Pre-Action sprinkler systems. Refer to listee's data sheet for additional detailed system description and operational considerations. System components: MCP RHU RHU w/o display ORB MCP/RHU Pwr. Supply MCP, MCP ULC Enclosure RHU, RHU ULC Enclosure RDU RHU Enclosure w/o Display Main Control Panel Remote Hazard Unit Remote Hazard Unit Optional Relay Board Power Supply Enclosure Endosure Remote Display Unit Enclosure w/o window Primary: 120/240 VAC, Standby: 24 VDC In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating and UL label. Listed as fire alarm control unit for use with listee's separately listed electrically and functionally compatible initiating and indicating devices. This control unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. *Rev. 06-21-2003 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: 7300-1076:116 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Kidde-Fenwal Inc., 400 Main St., Ashland MA 01721 Contact: Terrill Garland (508) 881-2000 FAX (508) 881-1773 DESIGN: Models 2-WIRE, 2WRLT, 2WRB, 4WRB, 4SB, 6SB smoke detector bases, Model *ASMSB (70-200200-002) addressable signal sounder module with base and Models MA-001 and MA- 002 smoke detector adapters. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10.2 - 36.8 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Models 2-WIRE, 2WRLT, 2WRB, 4WR13 are listed as smoke detector bases and Model MA- 001 is listed as a smoke detector adapter for use with Models CPD-7051 (CSFM Listing No. 7271-1076:115), PSD-71 55 or PSD-7 156 (CSFM Listing No. 7272-1076:117) smoke detector heads and separately listed compatible fire alarm control units. Models 2WRLT, 2WRB, 4WRB, 4SB and 6SB are also suitable for duct applications when used with Model RCM500 remote test/LED. Models 2WRB and 4WRB are suitable for releasing device service. Models 4SB, 6SB are listed as smoke detector bases and Model MA-002 is listed as a smoke detector adapter for use with listee's separately listed Model Fenwalnet 1000 (CSFM Listing No. 7165-1076:114), Fenwalnet 2000 (CSFM Listing No. 7165-1076:141), Fenwalnet 4000 (CSFM Listing No. 7165-1076:111) or Pegasys (CSFM Listing No. 7165-1076:146) fire alarm control units. *Model ASM-68B is listed as a smoke detector base with addressable signal sounder module for use with detector Models PSD-7152 (CSFM Listing No. 7272-1076:142), CPD-7052 (CSFM Listing No. 7271-1076:145) and THD-7252 (CSFM Listing No. 7270-1076:143) smoke detector heads and separately listed compatible fire alarm control units. *Rev. 08-05-03 .0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy • Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: 7272-1076:117 Page 1 of I CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: Photoelectric Smoke Detector Kidde-Fenwal, Inc., 400 Main St., Ashland MA 01721 Contact Terrill Garland (508) 881-2000 * FAX (508) 881-1773 Models PSD-7 155 and PSD-7 156 photoelectric type smoke detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with 2-WIRE, 2WRLT, 2WRB, 4WRB or MA- 001 bases (CSFM Listing No. 7300-1076:116) and separately listed compatible control units. Suitable for duct applications having air velocity of 500-4000 fpm when using Models 2WRLT, 2WRB or 4WRB bases. Suitable for releasing device service when using Models 2WRB or 4WRB bases. NOTE: Formerly 7257-1076:117 Rev. 06-21-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This-listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING . BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0785:118 Page 1 of I CATEGORY: Audible Devices LISTEE: Wheelock Inc.. 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Model MT-1 2/24, MT-1 15 and MT4-1 2/24, and MT4-I 15 multi-tone audible devices followed by R, W, S, or X to indicate package color. Models MT-I2, MT4-I2, MT-24, MT4-24 multi-tone audible/strobe signals followed by A. B, G, R or W to indicate lens color, followed by S (15 Cd), H (15 Cd) or M (117 Cd) to indicate strobe intensity, and other suffixes to designate orientation, lens lettering and plate color. Models MT-1 15-WH and MT4-1 15-WH multi-tone audible/visual devices (Rated 15 Cd). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Suffix -12: *175 VDC -24: *I33 VDC -115: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models MT series are surface mount and suitable for outdoor with Model lOB back box. Models MT4 series are flush mount and suitable for outdoor with model WBB back box. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Not suitable for the hearing impaired application. These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. Rev. 12-22-2002KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1076:147 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Kidde-Fenwal, Inc., 400 Main Street, Ashland, MA 01721 Contact: Temll Garland (508) 881-2000 *FAX (508) 881-1773 DESIGN: Models BIO and BII, 30-195000-002 and 30-195000-004 key lock, push bar, noncoded manual pull stations; Models 30-195000-001 and 30-195000-003 key lock, no push bar, noncoded manual pull stations. Suitable for outdoor use when installed with Model SGB 32C back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. Listed as manual pull stations for use with separately listed and compatible fire alarm control units. XLF: 7150-1408:107 *Rev. 06-21-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. ARENR Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING.MATERIALS• LISTING PROGRAM LISTINGS SERVICE LISTING No: 7300-1076:120 Page 1 of I CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: Misc. Devices/Control Unit Accessories Kidde-Fènwal, Inc., 400 Main Street, Ashland MA 01721-2150 Contact: Terrill Garland (508) 881-2000 *FA)( (508).881-1773 Models P/N 30-232001-001 front panel wlcutout for audible and P/N 30-232001-002 front panel •w/o cutout for audible. These units have a manual release switch and abort switch. Models 878752-01/-02, 30-193000-001/-002 abort stations. Models 296105, 30-193000-003 back boxes. Models 30-322003-003, 84-322003-003 Remote Display Unit Backbox. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only. Listee's name, model number, and UL label. Models 30-232001-001 and 30-232001-002 are listed as control unit accessories when used in conjunction with listees' separately listed fire alarm control units. Models 878752-01/-02,30-193000-001/-002 abort stations and Models 296105,30- 193000-003 back boxeè are intended for use with listed releasing device control units. *Rev. 06-21-2003 RH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager