HomeMy WebLinkAbout2290 COSMOS CT; ; FA040066)N ESLP City of Carlsbad Fire Alarm Permit Permit No: FA040066 Job Address: 2290 COSMOS CT Permit Type: FALARM Parcel No: 2130504400 Lot #: 0 Reference No.: Status: ISSUED Applied 8/12/2004 Approved: 9/27/2004 Issued: 9/27/2004 CARLSBAD FIRE PREVENTION DIVISION Permit Application For /e~ Check or fill in pertinent information for e of permit you . r bmittmg. AS -Automatic Sprinklers (Check off type ofplans being submitted) New System - How many risers/levels? r4jao Tenant Improvement Residential - How many systems and/or buildings? Underground for approval Underground included for reference only FA - Fire Alarm 25 Devices or less V Over 26 devices # of devices FS -Fixed Systems (Circle One) Hood & Duct, Special Chemical Agent Suppression System, Standpipe, Spray Booth or Appliance. Failed Inspection fee is $65.00. Name of Project: Total Fees Total Fees /S Total Fees Address ofjob site: go dpSsu2- e4- Suite # Building Permit # CB,t'Y Contractor Information Name Address S,3~7 36 City, State, Zip Phone FAX ( hO) '157-iS' I Kind of License and Exp. Date Do you currently have Certificate of Insurance on file with the Fire Dept? es r No Do you currently have a business license on file with the City of Carlsbad? r No Signature ____ Date'd/i QL1o'i Please estimate at least 10 business days for plan review comments and/or approval. We will contact you by telephone when the plans are approved/disapproved. Thank you! Permit Application Forin.doc 08/06/2004 Carlsbad Fire D rtment N)') Y-51--15-61 040698 1635 FardSyAve. 114 Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Alarm System Plan Date of Report: 08/31/2004 Reviewed by: C. Name: ADT Security Address: 3830 Calle Fortunada City, State: San Diego CA 92123 Plan Checker: Job !T!sMsIJeJ: - Job Name: Sierra Wireless Bldg #: CB040698 Job Address: 2290 Cosmos Ct. Ste. or Bldg. No., Approved The, item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions inthis report can result in suspension of permit to construct or install improvements. O Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and I or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this - - office for review and approval. Review 1st __________ 2nd _________ 3rd __________ Other Agency ID FD Job # 040698 FD File # Requirements Category: Alarm System Plan Requirement: Pending 13.25 Additional Requirements Remove duct detection from monitoring plan. Page 1 08/31/04 FAo4ôo SIERRA WIRELESS 2290 COSMOS COURT CARLSBAD, CA. 92009 FIRE ALARM SUBMITTAL Submitted By: mAi 3830 CaMe Forhnmda San Diego, CA 92123 (858) 654-3173 Contact: Stacey Tescier SIERRA WIRELESS FIRE ALARM SUBMITTAL MODEL # MAN1?. CSFM# FIRE ALARM CONTROL PANEL FOCUS 200 ADT 7165-0085:171 FIRE ALARM ANNUNCIATOR 471210 ADT 7165-0085:171 SMOKE DETECTORS 429CAD ESL/SENTROL 7272-0447:128 CONNECTION TO EXISTING WATERFLOW AND PW LOT 14/2 FIRE CABLE ADT/PAIGE/GENISIS 7161-1487:100 LOT 18/4 FIRE CABLE ADT/PAIGE/GENISIS 7161-1487:100 LOT 18/6 FIRE CABLE ADT/PAIGE/GENISIS 7161-1487:100 FOCUS 200 A , i The Next Geneiation Security Systems INTRODUCTION The FOCUS* 200 is a UL Listed burglar and tire alarm system which provides individual point annunciation and customization features. The system monitors 255 points of protection including burglar alarm, fire alarm, holdup alarm, supervisory and other types of points. Burglar alarm protection, can be divided into eight separate groups, each with multiple opening and closing schedules. The system is controlled by entering a User ID Code on an English language interactive keypad. FOCUS 200 provides 99 individual User I]) Codes to maintain a high degree of security and an audit trail of the most recent 500 events. The 500 event buffer can be viewed on the keypad or output to a local printer. Unique to the FOCUS 200 is ADVs exclusive Sensor Interface Module (SIM) technology which utilizes a microchip manufactured inside security and fire alarm devices. Each of the 255 devices reports as a unique point. Each device has a factory generated identification number on a microchip hermetically sealed inside the device. The FOCUS 200 polls each device and only accepts those devices answering with the proper Identification number. Because the* 11) is sealed inside the device and known only to the FOCUS 200, an extremely high degree of interoal line security is afforded, and device substitution prohibited. MAJOR ..FEA 7 VES 255 Points Of Protection High Security SIM Chip Devices DES Encrypted Communication 99 Passcodes l6Keypeds 8BAGroups 255 User Privilege Levels 500 Event Buffer Universal ConumWicator 4,000' RS-485 Bus Listed for Life Safety Meets ADA Requirements UL Listed FM Listed CSFM Listed ULC Listed NP?A71,NFPA72 UL609, UL61 1, UL636, UL864, UL1610, UL16 BY DESIGN Specifically designed to meet the requirements of Commercial, Banking, Retail and Industrial customers, the FOCUS 200 provides unparalleled features at a reasonable price. Modular in nature, the FOCUS 200 can cost- effectively meet the needs of a small branch bank with fewer than 20 points of protection or expand to cover a 255-point factory or large retail facility. TECHNICAL SPECIFICATIONS Control Unit Cabinet Dimensions 13-3/4" W x 16-3/8" H x 3-7/8" D Color: Warm Brown (34.9cm'x 41.6 cm x 9.8 cm) Control Unit Weight 12 lbs. (5.45 kg) Control Unit Electrical Power 120V, 60Hz, Class II (Primary) 16.5V, 60Hz, 50VA or 82VA (Secondary) Backup Battery 12VDC,7AH Sealed lead-acid (1 or 2-6 ired in parallel for rating up to 42AH) Charge Voltage to Battery (Fuse P3) Fuse: 3.75A, Solid-State Resettable Standby Battery Requirements 4 Hour ( 7 A.H Battery) 24 Hour (28 AN Battery) ___ 80 Hour (42 AN Battery) CommunicationOpti6ns With FOCUS 200 DES Encryption via AC, RS-232, SNA/SDLC. Universal Communicator Single or Dual Line FSK - Control Unit Power Output to RS-485 Bus 13.9V nominal. Maximum Current: l000mA RS-485 Bus Fuses: (Fuse Fl & F2) Fuses each: 1.85A, Solid-State ResettabLe Maximum Cable Runs Total RS485 Bus: 4,000' Per Gateway Trunk: 1,000' - Per Device to Trunk: 100' Sensor Interface Mddule (SIM) Maximum Line Resistance: 3K ohms Supervisory current: 0.2rnA End-of-Line Resistor: 33K ohms, 5%,1/2W Loop off-normal Retard: 800 mSec Point Interface Device (PID) Maximum Line Resistance: 900 ohms Supervisory current: 3mA End-of-Line Resistor: 3,010 ohms, 1%, 1/2 \V Loop off-normal Retard: 800 mSec. Environmental Operating Temperature Range: 32° F (0° C) to 120° F (490 C) - Auxiliary Relays RL-1 & RL-2 SPDT, Contacts rated 2A @24 VAC or 24 VDC Relay RL-3 (Voltage output) Jumper selectable 12 VDC @ 200mA -- or -- __________________________________ 22VDC ® 0mA rated 2A @ 24 VAC or 24 VDC Keypad - 16 Maximum Operating Panel Dimensions 8"W x 3"H x 1-1/2" D Color: Off white body, gray front (20.4cm x 7.7cm x 3.54 cm) Keypad Weight 14 oz (40 g) Keypad Operating Current - 32mA (inactive) 64mA (active) pprovals Underwriters Laboratories Inc. (UL) Federal Communications Commission (FCC) Factory Mutual (FM) California State Fire Marshall (CSFM) Underwriters Laboratories of Canada (ULC) OCUS 200 Complies with 1JL609, tJL611, tJL636, tJL864, 1.1tl61 0. UL1635, NFPA71 and NFPA72 Call ADT Security Systems: IC I94 ADr suricy syccrns USA: 1-800-ADT-4636 300 Incerpae Prkwa I.365.00(I2.94:20M) svotems Canada: 1-416.226-9221 Parsippany, N.J 07C54- - - FOCUS 200 PLUS Installation and Setup Guide Installation Criteria Control Unit Current Draw Standby 300mA Alarm 440mA - - Temperature Range 32°F (0°C) to 120°F (49°C) Dimensions 18" H x 14.1/2" W x 4.3" D Maximum Cable Runs RS-485 Bus #1 4000 Feet RS-485 Bus #2 4000 Feet SIM Gateway Trunk 1000 Feet PID Gateway Trunk (FB2 plus TB3) 1000 Feet Branch Cable for PID and SIM Sensors 100 Feet SIM Loop Trunk 2000 Feet Note: RS-485 bus and gateway trunk cable lengths may be 1e88, depending on current loading and voltage drop considerations. SIM Gateway Dimensions with Micro PID Housing - - 3.1/2" H x 3-1/2" W x 1.5/8" D (8.6cm x 8.6cm x 4cm) Temperature Range 32°F (0°C) to 120°F (49°C) Length of SIM Gateway Trunk 1000 feet (max.) Gateway Circuit Power Requirement 50ma Woist Case Voltage @ SIM Gateway 12.1VDC (End of Standby Period) (8.4VDC) Worst Case Voltage @ SIM Sensor 12.OVDC (End of Standby Period) (8.3VDC) SIM Resistor 33k 5% 1/2w PID Gateway Dimensions with Standard PID Housing 9-1/4"H x 5"W x 1.5/8" D (23.5cm x 12.7cm x 4.1cm) Temperature Range 32°F (0°C) to 120°F (49°C) Length of PID Gateway Trunk (TB2 plus TB3) 1000 Feet (max.) Gateway Circuit Power Requirement 50uiA Minimum Voltage to PID Gateway 12.1VDC (End of Standby Period) • 8.5VDC Voltage to Farthest P1]) on Gateway Trunk 12.1VDC (minimum) (End of Standby Period) 8.5VDC Worst Case Voltage to Sensor 11.6VDC (End of Standby Period) 8.OVDC Sensor Current from P1]) Standard PID 85mA maximum (current limited) Maximum PID Loop Resistance 900 ohms PID Supervisory Current 3mA PID End-of-Line Resistor 3,010 ohms, 1%, 1/2W PID Loop Off Normal Retard 500mSec. Note: With AC power off and the battery fully charged the voltage to a sensor being powered by the system must be greater than the rated minimal voltage of the sensor. 22-2 - Section 13— Power Requirements Table 2: SIM Gateway Standby and Alarm Loads Gateway Unit No. ________ (Maximum 72 Points) A B .AxB C AxC Standby Total Alarm Total Alarm Device Quantity Current (mA) Standby Current Current Current (mA) (mA) (mA) SIM Door Contact 1 1 SIM PIR Motion 1 5 SIM Dual Motion 5 . 5 SIM Smoke Detector . -. 3 5 SIM Holdup Button -. 1 SIM FA Pull Station 1 1 SIMs. Total Loads Of SIM Sensors Standby Alarm (Total alarm load must not exceed 128inA) Horn/Strobe Sounder 472307 10 . • . 10 Powered Sensors 4 Relay Total Standby and Alarm Loads Standby Alarm on Gateway Trunk SIM Gateway f 1 50 50 50 50 Total Gateway Standby and Standby Alarm Alarm Current SIM connected to external contact, powered sensor, self-powered sensor, output SIM, or horn/strobe . 190inA for bell mode with strobe, 260inA for horn/strobe 13-3 BATTERY TABS Ccnneot lo 12V. ?AN n1104.4A14 max EO IeS4 ebstIefl,a tlig cables ulBplsd. See k,ekulsa.n be mqatmd cepadlv. fast dlalolla vallsgs 13.7VOC. B.flsly SLIT need not be mpieced for t=- 3pm. Bssesy calvisotlan is POWER SEVEN 04 am am N2' 1" ALARM CURRENT Pins 112 ellallod • 2.3* Meat INS malI 47204 pallda.me,. Pkis 213 elIcited - ISA MtI INS WIll 443215*15157 Asid. 4724005 00154111 5.44. Ic5Ma Val.M0C1telNQDIR,IJl) I is3 j°T'r, 41 0PTI0tIAL4724O2A SAcic.UP DIALER MODULE L TYPES Of 001 SIONAU.ING SIRMOL ULUmled ILthisdissNcaMibNAcode. Mi 05N $laleflpi4Ied5dRUvisSS ills edan tend VAN bsdetv dsle.flujs. babillellon SNA Mill at lied Neily. sf.zriE I liii 9 2 sacu. .,iasatjscx BSTELGO 0015 cedlsesiapce 2 i.RNIB ,Miaed.eeei milsiseelsit X X isemedislil seated eel THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL. FIRE PROTECTION ASSOCIATIONS STANDARD 72. CHAPTERS (NATIONAL FIRE PROTECTION ASSOC.. BATTERYMARCH PARK. OUINCY. MA. 03259). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION. OPERATION. TESTING. MAINTENANCE. AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEAD. QUARTERS OR A CENTRAL STATION SHALL BE PERMITTED ONLY WITH THE APPROVAL 06 THE LOCAL AUTHORITY HAVING JURISDICTION. THE BURGLARY ALARM SIGNAL I1 I SHALL NOT BE CONNECTED TO A (J POLICE EMERGENCY NUMBER. JUMPER P3 Mm Relay Setting R111 112 shaded - Wet P. 23 Shorted• ely mntinsd2kn Illr@rn.ux p.. 12. sux p., 53 00 telsy tlnhlleul 10 (.hen Iafl IlOtaxoSud Msd alum ajn.nI 4,5.0 sex p., 52. sex p.. 53. IV! NOTE E U= 211 EOLR is. SeMi N. (_ NOTES: Sao beI,una for inca. I at f,,. feel no length FTATSINL9 OUTPUT: ISVAC. 75VA UCJ 472404 .led.ln Veratommowith enclosm FIPUT: I29VFC. 1.0*. S0HZcalme0iss 72VA = OUTPUT: IBYAC. 504* I AC WIRING IS SUPERVISED MeSa BS M4t2cab4 j . TIlhi5St bw 1'MAINDIALER — C©US Bablip Hsed.fI72I0204 I The Focus Built-In Dialer I a, AC cciilMm0n mealds 472491 Jedi Compiles wIth FCC Rules Part 68 FCC Reg. No.: AC398R-6192-AL-EI Ringer Equivalence: O.7B THIS DEVICE COMPLIES WITH PART IS OF FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (I) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE. AND (2) THIS DEVICE MUST ACCEPT ANY APPROVED INTERFERENCE RECEIVED. INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. ROIX p.- nNS I WARNING: OWNERS INSTRUCTION NOTICE NOT TO BE REMOVED TEST BURGLARY SYSTEM WEEKLY REFER TO INSTRUCTIONS 1(3471 FOR ACOmONAL INFORMATION NOTE: I IoIII+ 1. /II1I. I- (M '" Ls is .d is Shost pIn. 213 on P4. 0c1b.ueedloeate4000.ns.d&lr. —I---- 1// =-47244 " II I AUX RELAY (FORM C) eWe Tel Red Be. Mn Yet Red eli may be used fatal Sated conhmetdsl (SIng. Total burgilbe) InstaIIsiIans. Total Stan.. cult.nt Is I , Iln4t.d102.3A. IS 001.1. Sho.1 pins ll2on P4. FTA7SISULC II I 1.7* tees.. see not. I AUXILIARY POWER 12412 WNEN 0 NO esSege on isI 10. .lb.. jNZ— may be ud IC, tt Sst.d commeflisl 12 (burg, 2k(naie 2) CaMeORating:2eV.2Amu.. Rsi.1g life. burgitlru) instsllstlans. Total Stalin 0010501 is looted to2.3*.... flats I. Shalt I 1200 P4. 5115 AI.ARM POLARITY SHOWN POINT 1.1 NOTES I. • NC NC N C NC Dolts AIpak1ade St4. B sisieWIslan teeFIRE CICTS Supehaxe UsIng 211 ECIR. Ol115 1,2: 1000141.5 max Us. polansed 5C(Ildng 05511.5. . 0111sf paM!: 30001555 11155 EOLRe not r.qd. May ese non • Raisige tat • • BURG CKTS: Supervision not ,eq'4 • Pals reepama: 250-5004.5 lee s) 25515142) 2k Ilk devises. RetJne: 12V0C, 1.7A palaslud aWa. 'V••••' Ses loIs 1.3.. V.lttuelani to etleblajatssble . 2mA max for wickS del. (up loll 4.1400,5 SI Folds $14 may 'D be 5t Iota StI. supervision and for caireatible devIce.. 011115 type epedeed ee issttuotlons coedlgte*tlan. I A oo not mis 5.. end bu.g. seesa.. an ale loop. N.C. wle04 Ia, burg. esags FOCUS 200 PLUS SUMMARY OF CONNECTIONS (472442*) N.C. WARNING: TO PREVENT RISK OF ELECTRICAL SHOCK, DISCONNECT TELCO JACK * + . • • BEFORE SERVICING This PANEL N.C. . NC. ALL CIRCUITS ARE POWER I LIMITED EXCEPT THE OUTPUT I N.O. NO. NO. 06 THE 472404 TRANSFORMER 2! 2k 2! so Box Loop ThuDs, CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1574:157 Page I of I CATEGORY: Control Unit (Non High-Rise) LISTEE: ADT Security Services, Inc., 695 Route 46 West, Suite 200, Fairfield, NJ, 07004-1561 Contact Ron Dalton (310)725-2972 FAX (310)725-2942 DESIGN: Models "Focus 200" 472362 and 472363; wFocus 200B" 472362B fire alarm control units. Power-limited; local, manual, automatic, proprietary, remote station and central station and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 472362, 472362B, 472363 472368 248239 471715 248259 472398, 472399 471210 472372 472366 472381 472364,443219 471877 471941 471943 472388 Control Unit SIM Gateway PID Gateway Printer Interface Battery Cutoff Module Communication Module Keypad Power Supply Interface Module Auxiliary Power Supply Transformer Quad PID Module Micro PID Module Micro PID Housing Horn/Strobe SIM INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Inc. Label APPROVAL: Listed as a fire alarm control unit for use with separately listed electrically compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72,1999 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal Refer to manufacturer's Installation Manual for details. NOTE: 1. Model Focus 200 control units are a revision of and operate similar to listed Model Focus 100 (CSFM Listing No. 7165-1574:149). For additional accessories, refer to the Focus 100 listing. 2. Formerly 7165.0085:171 05-20-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation cnterla. Refer to listee's data sheet, installation instructions andlor other suitable information sottces. Date Issued: JUNE 23, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager ES PRODUCT INFORMATION.BULLETIN 429 SERIES Self-Diagnostic, Two-Wire, Photoelectric Smoke Detectors Model numbers: 429AT, 429C, 429CT, 429CRT and 429CST nul USTED California State Fire Marshal Approved MEA (New York City) Intelligent, self-diagnostics Field-replaceable optical chamber Low-profile design Plug-in terminal block Advanced false alarm immunity The ESL 429 Series self-diagnostic, two-wire smoke detectors continually monitor their own sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitiv- ity range or fail internal diagnostics. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detector's integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. The 429 Series is easily cleaned by simply replacing ESL's proprietary field-replaceable optical chamber. All models are designed to reduce false alarms from dust, insects, RFI and external light. An integral combination rate-of-rise and fixed 135°F (570C), 50-foot rated, heat sensor is available with all 1" model detectors (see selection guide). An inte- grated silicon heat sensor and a dedicated micropro- cessor are used to detect heat and perform the rate of rise calculations, for earlier heat detection. continued ESL 429 Series Smoke Detectors Architectural and Engineering Specifications The ESL 429 Series low-profile, self-diagnostic, two-wire smoke detectors work on the light scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high-speed photo-diode as the sensing element. When the amount of light reflected onto the photodiode reaches the sensitivity setting, the smoke sampling rate increases. Three (3) successive smoke sensings above the sensitivity setting are required to sound an alarm. This design has superior protection against false alarms caused by dust, insects, RF and ambient-light. A confirmed alarm causes the normally flashing power indicator LED to light continuously and the optional alarm relay (available in °R models) to operate. A trouble indica- tion is automatically displayed by flashing the LED every second. This meets NFPA 72 field sensitivity testing require- ments. An internal 85 dB horn (available in °S models) emits a steady tone when the detector alarms and a pulsed tone when power polarity is reversed. Product Data Sensitivity .........................................max.......3.1 - 1.00/o/ft. mm 3.1 + 0.50%/ft. Operating temperature range ......................... 32°F to 120°F 0°C to 50°C Operating humidity range.................................0 to 95% RH Minimum voltage - C, CT, CRT, CST............................8.5V -AT ....................................................6.5V Maximum voltage - C. CT, CRT, CST...........................33V -AT .....................................................20V Maximum ripple (peak to peak)......................................10% Typical average standby current .................................. 70tA Field wiring size................................................14 -24 AWG Alarm current.....draws max of 60 mA if not limited by panel The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Models with auxiliary relays are approved for releasing service. The very low profile 429 Series detectors are equipped with a hinged cover, a concealed tamper-resistant latch, and insect screens. All wiring terminates in plug-in, clamp-type screw terminals. The detectors mount to a standard single-gang electrical box, a four-inch octagonal, four-inch square electrical box, or WIREMOLD No. 5739 fixture box. Smoke Detector Spacing On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (9.1 meters) may be used as a guide. Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. Max. avg. polarity reverse current - CST ....................lOmA Sounder specifications....................................85dB at 10 ft. Heat detector specifications: Fixed temp . .......................... 135°F ± 5°F (57.2°C ± 2.8°C) Rate of rise .........15°F/mm.,> 105°F (8.30C/mm., > 40.6°C) Relay specifications .......................2A@28V0C or 1 2OVAC Packaging ....................10 detectors are packed in a carton Color.................................................white cover/white base with UV inhibitor to prevent yellowing 2-wire compatibility..................see ESL Compatibility index Listings ........UL 268, FM, CSFM and MEA (New York City) for Canadian ULC listed products use 428 series Selection Guide 1.85° 470 an Designator Feature Description Isolated Fixed Temp. Isolated fixed 135°F (57°C) and rate of rise heat detector. independently trips the LED and alarm H and Rate of Rise Heat relay output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but Detector does not latch. Approved as both single station smoke alarm and system heat detector. Ideal for hotel, motel and dormitory rooms where smoking Is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall, door holders, strobes, etc. Listed for releasing service. S Built-in Sounder 85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. Integrated Fixed Integrated fixed 135°F (57°C) temperature and rate of rise heat detector oilers double protection. T Temp. and Rate of Either heat detector or smoke detector can trip and latch LED and alarm relay outputs. Rise Heat Detector interlogict c...slu& IGIC I" lu&.i. Is.'.. Pr 503692.4052 05*&CaM 0.5472S56 T.SW* 9006417424 F.da I0Lt4S324 w.MsflDdces ww selogiác.com mt9 caw Is,cm ad sawd M. PIdaa w, p'aada E4079ST2• OOC CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0447:128 Page 1 of I CATEGORY: Photoelectric Smoke Detector L1STEE: ESL/Sentrol Inc., 12345 SW Leveton Dr., Tualatin, OR 97062 Contact Gene Hukkanen (503) 691-7369 FAX (503) 691-7575 DESIGN: Model 429-AT, -C, -CAD, -CT, -CTAD, -CRT, -CST or -CSST; and Model 449-AT, -C, - CT, -CRT, -CSRH, -CSRT, -.CS(S)T, -CSSTE, -CSTE, -CTE, -CLT or -CSLT photoelectric type smoke detectors. Units may employ an integral heat sensor (1350 F fixed temperature and 15° F per minimum rate of rise) and sounding device. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with Iistee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Ustee's name, model number, electrical/temperature rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed electrically compatible fire alarm control units except *Models 429CAD and 429CTAD are intended for use only with ADT Model Focus 200 (CSFM Listing No. 7165-0085:171). NOTE: Integral heat sensor and sounder are supplemental to smoke detector. *Rev. 07-17-96 This listing is based upon technical data submitted by the applicant. CSFM Are Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information soma. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager SECTION 2 FIRE ALARM CABLE I PA9TNUSER I I0RI SMM I WML I 2.20 SEC i? CALL I 8&A%-423-c947 I ucrn I '' I Eff] cam Icom Raw wmmm SI.OI.HIfl. eIT( 300v 180 . ' . IMONM us 12224WG SRN &(. IvfpLv cw 0RNflUL P991. T 1000 BL.. o 16.0 OT wc LOS 21eAWG 909 TYP( IPLPI cmp NO 8.0 40T 493490 LOS AWG 1 ON TYPE fW cmp ('*J LH1 Owl.. 16.0 AUT 49340 60.c 1000 VEUOW LOS ZOC19 NAIG __ TP( FI'tPV cw 8.0 4W 493493 LBS 218A __ TYPE PLPI cmp (IL) ORDERS I'ION[ 138-423-8947. FAX 847-797-3853 I 2.21 SECTION 2 FIRE ALARM CABLE movilom 0*TPML' F I IuRI 1b0. I ei*tnu4 I COtOUCT0R I JT I VOLTAC I I w.os I It0t I ' I I I mr I IRS 14 SMIG PED 300v 50.0 *m 494472 2 7s.c 5 LI 14 2 IS rm Is UGHT BURl TYPE IPLPI s.-. L0w 5( qD 35.0 SOT 493491 low LBS 2R1IAVG PEa TY tPLPIcm 0*3 19.0 SOT 493491 sm LBS 211G fm IMF" xxv 0*3 mAQI. RED 72.0 lPtP.3P eWE LBS 14PG ('*3 2.26 DON'T sti IT? CALl. 1-8884238947 ORDERS: PHONE I-88 4238947. FAX 841 2.27 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1487:100 Page 1 of 1 CATEGORY: Cables-Fire Protective Signaling LISTEE: Genesis Cable System, 7701 95th Street, Pleasant Prairie, WI 53158-2716 Contact: Orville Allen *(262) 947-0720 Fax (262) 947-0724 DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-1 50, Foam PP, HDPE or LDPE Assembly: 2 to 12 Insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT-45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. MARKING: Ustee's name, Type "FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data subntitted by the appkcanL CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, Installation instructions and/or other suitable information sources. Date Issued: JUNE 23, 2004 Usting Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager