HomeMy WebLinkAbout2290 COSMOS CT; ; AS040074City of Carlsbad Sprinkler Permit Permit No: AS040074 Job Address: 2290 COSMOS CT Permit Type: SPRINK Parcel No: 2130504400 Lot #: 0 Status: ISSUED Applied 5/20/2004 Approved: 6/10/2004 Reference No.: • Issued: 6/10/2004. PC #: Inspector: Project Title: SIERRA WIRELESS FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: GRANDONA INVESTMENT ASSOCIATES L P 2610 HARRISBURG AVE FREMONTCA Fees ($) Add'I Fees ($) Total ($) Balance ($) 506.75 0 506.75 .. 0 Model BV-20 QR 8.0 K-factor Quick Response Extended Coverage Light Hazard Pendent & Rec. Pendent Glass Bulb Automatic Sprinkler Tyco Fire Products - www.centralsprinkler.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446— USA Customer Service/Sales: Tel: (215) 362-0700/ Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 CENTRAL 111141111111w, U.! Description The Central Model BV-20 OR, 8.0 K-factor Quick Response, Extended Coverage Light Hazard (ECLH) Pendent and Recessed Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies such as churches, hospitals, offices, and restaurants. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules (e.g., NFPA 13) for the protection of light hazards up to a maximum cover- age area of 400 ft2 (37,2 in2), as compared to the maximum coverage area of 225 112 (20,9 nf) for standard coverage sprinklers. The recessed version of the Central Model BV-20 OR ECLH, intended for use in areas with a finished ceiling, uses a two-piece Model ELO Recessed Escutcheon. The Model ELO Recessed Escutcheon provides up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by these Recessed Escutch- eons reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut Operation: The glass bulb contains a fluid which expands when exposed to heat When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate & flow water. WARNING The Model BV-20 OR ECLH Pendent Rec. Pendent Sprinkleis descnbed herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Technical Data Sprinkler Identification Number SIN C4232 Approvals UL & ULC Listed. (The approvals apply only to the service conditions indicated in the Design Criteria Section) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 4 inch NPT Discharge Coefficient K = 8.0 GPM4si112 (115,2 LPM/bar) Temperature Ratings 135°F1570C or 155°F/68°C Finishes Sprinkler White Polyester, Chrome Plated, or Natural Brass Rec Escutcheon White Coated, Chrome Plated, or Brass Plated Physical Characteristics The Model BV-20 OR ECLH Pendent & Rec. Pendent Sprinklers utilize a dedndfI- cation resistant (DZR) bronze frame and a 3mm bulb. The two.piece button assembly is brass and copper. The sprinkler frame orifice is sealed with a gasketed spring plate (Belleville Sea!) consisting of a beryllium nickel disc spring that is seated on both its inside and outside edges with a Teflon' gasket The compression screw is bronze, & the deflector is brass. *1 Extended Coverage Light Hazard Pendent & Rec. Pendent Me s Figure 1- Cross Section Model BV-20 QR ECLH, Pendent Sprinkler GASKETED SPRING BU1TON PLATE ASSEMBLY (BELLEVILLE SEAL) F SPRINKLER GLASS BULB (lt-JJ FRAME OPERATING ELEMENT / DEFLECTOR COMPRESSION SCREW General do so may impair the integrity of these devices. No. 2-10.0 Figure 2- Model BV-20 OR ECLH, Pendent & Recessed Pendent Sprinklers ELEVATION VIEW I / I FACE OF I I REDUCING I _________ / COUPLING I rL 1VH1N3 3/4" NPT 3/8" (9,5 mm) _________ 1 Mm. -1/8"(28,43 mm) \CEILING LINE Max. I FINISHED 21/8 OUTER ' (54:O LT FLAT RING/ ._.-; L1-3116"J SUPPORT CUP RENCH ESCUTCHEON WRENCH FLAT MODEL ELO RECESSED ___________ RECESSED 2-114"(57,2 mm) Mm. ESCUTCHEON (30,2 mm) .114" (82,6 mm) Figure 3- W-Type 3 Sprinkler Wrench (Part #1073) Figure 4- ELO Offset Wrench (Part #1093) Table 1- UL and ULC Listing Criteria for the Installation of Model BV-20 OR Extended Coverage Light Hazard Pendent Sprinklers Minimum Spacing Flow/Pressure Style Temperature Rating LH (0.1 gpm/sq. ft.) 16' x 16' 26.0 gpm /10.6 psi Pendent 135°F/570C 155°F1680C (4,9 m 4,9 m) 98,4 Lpm / 0,73 bar Recessed Pendent 1350FI570C 155°F/680C 18' x 18' 33.0 gpm 117.0 psi Pendent 135°F1570C 155°F/680C (5,5mx5,5m) 124,9 Lpm /1,l7bar Recessed Pendent 135°F/570C - 20' x 20 40.0 gpm /25.0 psi Pendent 135°F/570C - Al m 6,1 m) 151,4 Lpm /1,72 bar Recessed Pendent 1350F/570C - 3Design Criteria The Model BV-20 OR, Extended Coverage Ught Hazard (ECLH) Pendent and Recessed Pendent Sprinklers are UL and ULC listed for use in light hazard occupancies, using the design criteria in Table I as well as any additional requirements specified in current NFPA 13 Standards for Extended Coverage Pendent Sprinklers. The minimum lateral spacing between the BV-20 OR ECLH Pendent and Recessed Pendent Sprinkers to prevent cold soldering, is 8 feet (2,4 m). The Model BV-20 OR Sprinklers can be used with any metalic flush or extended escutcheon, provided the maximum calling to top of sprinkler deflector dimension specified in NFPA 13 is maintained. For recessed applications, only the Model ELO Recessed Escutcheon Assemblies may be used. 13 Installation The Model BV-20 OR ELCH Sprinklers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble with an approximate diameter of 1/16 inch should be present. A leak tight 3/4 inch NPTspnnklerjoint should be obtained with a torque of 10 to 20 ft ft. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install 3/4 Inch NPT sprinklers. Higherlevels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit Step 1. Pendent sprinklers must be installed only in the pendent position. The deflector is to be parallel to the ceiling, roof, or mounting surface, as applicable. Step 2. After installing the ELO support cup (or other escutch- eon, as applicable) over the sprinkler pipe threads & with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the sprinkler using only the following wrenches: BV-20 OR Pend - W-Type 3 (Ref. Fig. 3) BV-20 OR Rec. Pend - ELO Offset (Ref. Fig. 4) Wrenches are to be applied to the sprinkler wrench flats (Ref. Fig. 2) only. a Care & Maintenance The Model BV-20 OR ECLH Sprinklers must be main- tained and serviced in accordance with the following instructions. NOTES Absence of an escutcheon which is used to cover a clearance hole, may delay the time to operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system it controls, permission to shut down the affected fire protec- tion systems must be obtained from the proper authorities. All personnel who may be affected by this action must be notified. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be shipped or stored where their temperatures will exceed 1000171380C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Sec- tion). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited V-i Ordering Warranty I±l Information Products manufactured by Tyco Fire Ordering Information: When placing an Products are warranted solely to the order, indicate the full product name. original Buyer for ten (10) years Please S ecify the quantity, model, style, against defects in material and orifice size, temperature rating, type of workmanship when paid for and finish or coating, and sprinkler wiench. properly installed and maintained Refer to price list for complete listhgof under normal use and service. This Part Numbers. warranty will expire ten (10) years Teflon isatrademark of the DuPont Cop from date of shipment by Tyco Fire Products. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, im- proper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Are Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Are Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's repre- sentatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. tqco/Flowcontroi/Tyco Fir. , Products Printed in U.S.A. 2-01 Model KI I ECOH Amih Model K14 ECOW, Extended Coverage EENTRAL Ordinary Hazard Sprinklers Tyco Fire Products - www.centralsprinkler.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Customer Services/Sales: Tel: (215) 362-0700/ Fax: (215) 362-5385 Technical Services: Tel. (800) 381-9312/ Fax: (800) 791-5500 General Description The Central Models K1 1 & K14 ECOH, 11.2 and 14.0 K-Factor, Standard Response, Extended Cov- erage Ordinary Hazard (ECOH) Pen- dent, Recessed Pendent, and Up- right Sprinklers are decorative glass bulb sprinklers designed for use in ordinary hazard occupancies such as showrooms, retail stores, and light manufacturing. They are intended for use in automat- ic sprinkler systems designed in ac- cordance with standard installation rules (e.g., NFPA 13) for the protec- tion of ordinary hazards up to a maxi- mum coverage area of 256 ft2 (23,8 M2) for the Ki 1 and 400 ft2 (37,2 m2) for the K14, as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers. The Models Ku 1 & K14 ECOH Sprin- klers feature a UL and C-UL Listing that permits their use with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13. The Models Ku 1 & K14 ECOH Sprin- klers have been fire tested to com- pare their performance to that of standard spray sprinklers installed at standard spacings (i.e. 15 feet maxi- mum on center spacing and 130 sq. ft. maximum coverage area for ordi- nary hazard). These tests have shown that the protection provided by these ECOH Sprinklers is equal to or more effective than standard spray sprinklers. The recessed version of the Models Ki 1 & K14 ECOH Sprinklers using a two-piece Series 4211 Recessed Es- cutcheon provides up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The ad- justment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Operation. The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands suffi- ciently to shatter the glass bulb, which then allows the sprinkler to ac- tivate and flow water. WARNINGS The Models Ku I & K14 ECOH Sprin- klers described herein must be in- stalled and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integ- rity of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Technical Data Sprinkler Identification Numbers SIN C5137 K=11.2 Upright SIN C5237 K=1 1.2 Pendent SIN C6137 K=14.0 Upright SIN C6237 K=14.0 Pendent Approvals UL and C-UL Listed. FM Approved. (Refer to Table A. The approvals ap- ply only to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT K11 & K14 ECOH Pendent, Recessed & Upright Sprinklers No. 2-1.1 K=11.2 ORDINARY HAZARD GROUP 1 ORDINARY HAZARD GROUP2 0.15 gpm1ft2 Density 0.20 gpmlft2 Density Coverage Area Maximum Distance From wall Ft Minimum Flow, GPM Minimum Pressure, PSI Minimum Flow, GPM Minimum Pressure, PSI Ft. x Ft. Sq. Ft 14x14 196 7 29.6 7.0 39.2 12.3 16x16 256 8 38.4 11.8 51.2 120.9 K=14.0 ORDINARY HAZARD GROUP 1 ORDINARY HAZARD GROUP 2 0.15 gpm/ft2 Density 0.20 gpm/112 Density Coverage Area Maximum Distance From Wall Ft. Minimum Flow, GPM Minimum Pressure, PSI Minimum Flow, GPM Minimum Pressure, PSI Ft. x Ft. Sq. R. 16x16 256 8 38.4 7.5 51.2 13.4 18x18 324 9 48.6 12.1 64.8 21.4 20x20 400 10 1 60.0 1 18.4 1 80.0 32.7 Table B UL and C-UL Listing Criteria For The Installation Of Model Ku 1 & K14 ECOH Sprinklers Nominal Discharge Coefficients K= 11.2 GPM/psi 2 (161,3 LPMIbari'2) K = 14.0 GPM/psi112 (201,6 LPM/bar"2) Temperature Ratings Pendent and Upright: 135°F/57°C to 2860F/1 82°C Recessed Pendent: 135°F/570C to 200°F/930C Finishes Sprinkler: White Polyester, Chrome Plated, Natural Brass, Lead Coated Recessed Escutcheon: White Coated or Chrome Plated (Other finishes are available on re- quest.) Physical Characteristics The Ku I & K14 ECOH utilize a 3 m diameter glass bulb and a dezincifi- cation resistant bronze alloy frame. The frame orifice is sealed with gas- keted spring plate (Belleville Seal) consisting of a beryllium nickel disc spring that is sealed on both its in- side and outside edges with a Tef- lon? gasket. Design Criteria The Models Ku 1 & K14 ECOH Sprin- klers must only be installed in ac- cordance with the applicable UL and C-UL Listing or FM Approval require- ments as indicated below. Only the Series 4211 Recessed Escutcheon is to be used for recessed installa- tion. UI and C-UL Listing Requirements The Models Ku I & K14 ECOH Sprinklers may be used for the coverage areas shown in Table B, based on maintaining the mini- mum specified flow rate as a func- tion of coverage area and hazard group for all of the sprinklers in the design area. With respect to heat sensitivity, the Models Ku 1 & 1(14 ECOH Sprinklers are permitted to be used with unobstructed or non- combustible obstructed ceiling con- struction as defined and permitted by NFPA 13. For example: Unobstructed, combustible or non- combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 t 12 inches (25 to 300 mm). Obstructed, noncombustible, ceil- ing construction with a deflector lo- cation below structural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceil- ing/roof deck distance of 22 inches (550 mm). The minimum allowable spacing between the Models Ku 1 & K14 ECOH Sprinklers, to prevent cold soldering, is 8 feet (2,4 m) for upright sprinklers and 9 feet (2,7 m) for pendent sprinklers. The Models Ki 1 & K14 ECOH Sprinklers are to be installed in ac- cordance with all other require- ments of NFPA 13 for extended coverage upright and pendent sprinklers. FM Approval Requirements The Models Ku 1 & K14 ECOH Sprin- klers are to be installed in accord- ance with the applicable Factory Mu- tual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protec- tion of certain specific ordinary haz- ard (non-storage and/or non-flamma- ble or combustible liquid) occupancies. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hy- draulic design, ceiling slope and ob- structions, minimum and maximum allowable spacing, and deflector-to ceiling distance. r3 Installation The Models Ku I & K14 ECOH Sprin- klers must be installed in accord- ance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The di- ameter of the air bubble is approxi- mately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141 °C temperature ratings. A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ftlbs. (40.7 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutch- eon Plate by under- or over-tighten- ing the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be in- 1/2" (12.7 mm) NOMINAL MAKE-IN 2-7/16" (61.9 mm) 1-11/16" (42.7 mm) ESCUTCHEON PLATE SEATING SURFACE WRENCH FLAT (BOTH SIDES) 2-7/8" DIA. (73.0 mm) FLUSH - (19.1*9.5 mm) - 2-1/4" DIA. 3/4"(19.1 mm) FACE OF (57.2 mm) SPRINKLER 1/8" FITTING (3.2 mm) MOUNTING /MOUNTING SURFACE/ SjJ( PLATE CLOSURE 5/8"(15.9 mm) 1-3(8" (34.9 mm) Figure 2 Figure 1 Models Ku I ECOH or K14 ECOH Models Ku 1 ECOH or K14 ECOH Pendent Sprinklers Pendent and Upright Sprinklers With Series 4211 Recessed Escutcheon SPRINKLER FINISH Pendent (C5237 or C6237) Upright (C5137 or C6137) Recessed (C5237 or C6237) wlSenes 4211 Escutcheon Temperature Rating Bulb Color Code Natural Brass Chrome Plated Polyester Coated (All Colors) Lead Coated Natural Brass I Chrome Plated Polyester Coated I (All Colors) 135°F/570C Orange 1,2,3 1,2 155°F1680C Red 1,2,3 1,2 1750F/790C Yellow 1,2,3 1,2 200°F/93°C Green 1,2,3 1.2 286°F/930C Blue 1,2, 3 N/A Notes: Listed by Underwriters Laboratories, Inc. Listed by Underwriters Laboratories for use in Canada (i.e., C-UL Listed) Approved by Factory Mutual Research Corporation. N/A: Not Available. Table A Laboratory Listings and Approvals (The laboratory listings and approvals only apply to the service conditions indicated in the Design Criteria section.) "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS Figure 3 W-Type 3 Upright and Pendent Sprinkler Wrench Figure 4 W-Type 4 Recessed Pendent Sprinkler Wrench stalled with the deflector parallel to the mounting surface. Pendent sprin- klers must be installed in the pen- dent position, and upright sprinklers must be installed in the upright posi- tion. Step 2. After installing the Series 4211 mounting plate (or other es- cutcheon, as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten upright or pendent sprinklers using only the W- Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pen- dent sprinklers using only the W- Type 4 Sprinkler Wrench. The wrench recess of the applicable sprinkler wrench (Ref. Figure 3 and 4) is to be applied to the sprinkler wrench flats (Ref. Figure 1). ]Maintenance Care& The Model Ki 1 & K14 ECOH Sprin- klers must be maintained and serv- iced in accordance with the following instructions: NOTES Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to operation in a fire situation. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem which it controls, permission to shut down the affected fire protec- tion systems must be obtained from the proper authorities and all person- nel who may be affected by this ac- tion must be notified. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be shipped or stored where their tem- perature will exceed 100°F/38°C and they must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprin- klers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slip- page, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Sec- tion). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer. for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under nor- mal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by com- panies not affiliated by ownership with Tyco Fire Products or for prod- ucts and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authori- ties Having Jurisdiction. Materials found by Tyco Fire Products to be de- fective shall be either repaired or re- placed, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Prod- ucts shall not be responsible for sprinkler system design errors or in- accurate or incomplete information supplied by Buyer or Buyer's repre- sentatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDI- RECT, SPECIAL OR CONSEQUEN- TIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POS- SIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EX- CEED AN AMOUNT EQUAL TO THE SALES PRICE. flOrdering infonnation Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, model, style, and size, as applicable. Refer to Price List for complete list- ing of Part Numbers. Please Specify: Model Ku 1 ECOH Upright Sprinkler. Model Ki 1 ECOH Pendent Sprinkler. Model K14 ECOH Upright Sprinkler. Model 1(14 ECOH Pendent Sprinkler. W-Type 3 Sprinkler Wrench. W-Type 4 Sprinkler Wrench. Series 4211 Recessed Escutcheon. Patents: U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256 are ap- plicable to the Models K1 & K1 ECOH Sprinklers. Other patents are pending with regard to other design features. Conversion Factors: lft.= 0.3048m 1 sq. ft.= 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpm/ft2 = 40.74 mm/mm tqca/Rowcontrol/ Tyco Fire Products Printed in U.S.A. 2-01