Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2003 COSTA DEL MAR RD; ; FA100011
10/6/2020 FAI 00011 Permit Data City of Carlsbad Fire Alarm Permit 2003 COSTA DEL Job Address: MAR RD Permit Type: FALARM Parcel No: 2162100301 Lot #: 0 Reference No.: Permit No: FAI 00011 Status: ISSUED Applied 3/16/2010 Approved: 3/16/2010 Issued: 3/16/2010 PC #: Inspector: Project Title: FORTH @ LA COATA TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: EMCOM ELECTRONIC SYSTEMS, INC. SUITE H 256 WITHERSPOON WY EL CAJON, CA 619-667-1200 Owner: MURPHY EDWARD A&JOY M REVOCABLE 2000 TRUST 7758 ANILLO WAY CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 1/1 EMCOM ELECTRONIC SYSTEMS, INC. CALIC.820216 SEC. L1CAC03838 256 WITHERSPOON WAY, SUITE H ' ELCAJON, CA 92020 • PH. (619)667-1200. FAX (619) 667-1222 Fire Alarm Equipment Submittals FILE COPY for Forth La Costa 203 02 Costa Del Mar La Costa, CA CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspetdon and required tests, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of these plans shall not be eld to ermit q IS By lb,,w plans have been reviewed for aØparent compliance oit the current applicable codet. andsiandards !PfOrce thu uiutlictuOfl. The owner or contractor niaviitiluie I Ins ret j, %% iii support of an application for a building pullout a uh the express understanding that this review 11,no way rlu,,xes the owner or contractor or their puOtessiotial engineer or arehiiecttor tote responsibility for full compliance with said codes and standirds. iticitu. iii; the building code or for any responsihihy for deficiencies. errors. omissions or iksligetwe in ttcse plans whether or not noted in this review. l)atc: y//,,//o Reviewer:' 13 RECOMMEND APPROVAL RECOMMEND APPROVAL. AS NOTED f k~ o oo~ ~ ,I?fAiT O,x1 Optional Adder Modules OCAC-304 Four Indicating Circuit Class "A" Converter Module The OCAC-304 converts four Class "B" (Style "Y") output circuits on the FX-350 to Class A" (Style "Z") circuits. The OCAC-304 is equipped with wire leads to connect to the FX- 350 main board. Remote Annunciators PR-300 Polarity ReversaUCity Tie Module The PR-300 provides outputs for city box and polarity reversal applications. As a city be module the PR-300 provides an interface between the control panel indicating circuits and a master box. As a polarity reversal module the PR-300 provides an interface between the control panel and a reverse polarity receiver. RAM-300LCDR Remote LCD Annunciator The RAM-300LCDR provides LCD remote annunciation through a 2 line by 20 character LCD display. The RAM-300LCDR provides control switches for System Reset, Signal Silence, Fire Drill and Acknowledge as well as a numeric keypad to access the menu functions. The common control functions can be disabled on a per function basis. The RAM-300LCDR has LED indicators forA.C. On, Alarm, Supervisory, Trouble and CPU Fail. The RAM-300LCD comes complete with a red enclosure and a CAT-30 Lock and key. RAM40I6IRAM4032 Remote LED Annunciators The RAM-1016 and RAM-1032 Remote LEDAnnunciator provide 16 or 32 points respectively of LED annunciation. Both models come standard with bi-coloured LEDs which are automatically configured for either Alarm (Red) or Supervisory (Amber). The annunciators have indicators forA.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. In addition both models allow for the control switches to be disabled on a per function basis. Both models mount in a BB-1001R enclosure. RAM-208RIRAM-216R Remote LED Annunciators The RAM-208R and RAM-216R provide 8 or 16 points respectively of LED annunciation. Both models feature bi-coloured LEDs which are auto-configurable for eitherAlarm (red) or Supervisory (amber). The LED annunciators have indicators forA.C. On, Common Trouble and Signal Silence and control switches for System Reset, Signal Silence, Lamp Test and Buzzer Silence. The RAM-208R and RAM-216R are equipped with a keyswitch which allows for enabling and disabling of the Common Control functions. Both models are available in a red finish and mount in a 4-gang electrical box. Ordering Information Model Description FX-350 Series Intelligent Fire Alarm Control Panels FX-350-60-DR Single Loop 60 Point Intelligent Fire Alarm Control Panel with built-in UDACT/Diital Communicator FX-350-126-DR Single Loop 126 Point Intelligent Fire Alarm Control Panel with built-in UDACT/Digital Communicator FA-300TRB Black semi-flush trim ring for FX-350 Series enclosures Optional Adder Modules OCAC-304 Four Indicating Circuit Class 'A' Converter Module PR-300 Polarity Reversal/City Tie Module Remote Annunciators RAM-300LCDR Remote LCD Annunciator RAM-1016 16 Zone Remote LED Annunciator RAM-1 032 32 Zone Remote LED Annunciator BB-1001R Enclosure for RAM-1 016 & RAM-1 032 Annunciators RAM-208R 8 Zone Remote LED Annunciator RAM-216R 16 Zone Remote LED Annunciator NOT TO BE USED FOR INSTALLATION PURPOSES. /////// 'k. Distributed by: Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates Vaughan, Ontario L41< 5W3 Niagara Falls, NY 14305 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://w.mircom.com Email: mail@mircom.com ISO 9001:2000 It REGISTERED CAT. 5670 Rev. 1 INTELLIGENT FIRE ALARM CONTROL PANELS FX-350 SERIES Description The FX-350 Series Intelligent Fire Alarm Control Panels are single loop addressable panels with support for up to 60 or 126 addressable points. The FX-350 Series panels are equipped with a two line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/ Digital Communicator. The FX-350 Series ftmily also includes remote LED and LCD annunciators. The FX-350 Series panels are ideal for both new and retrofit applications. Designed for small to medium commercial, institutional and industrial occupancies, these panels are powerful enough to meet today's installation demands. The FX-350 Series panels are configurable by the keypad for onsite programming or by a PC for both onsite and remote programming. Easy to install and simple to operate and configure, the FX-350 Series panels enable the installer to configure the system to meet their specific requirements. The FX-350 Series panels are equipped with a 5.5 Amp power supply, auxiliary resettable smoke power supply (300mA max.), an interface for a Remote Trouble Indicator (RTI-1) and an RS-485 interface for remote LCD and LED annunciators. All FX-350 Series panels come complete with a red door, black enclosure, durable CAT-30 lock and key and space to mount up to 12 AH batteries. Optional trim rings are available for semi-flush mounting. Features Listed to UL 864, 9th edition Single Addressable SLC Loop that supports 60 or 126 addressable points Points can be any combination of Addressable Sensors or Modules Supports Ionization Sensors, Photoelectric Sensors, Variable Heat Sensors and Multi—Sensor (Heat/Photo) Equipped with a 2 line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/ Digital Communicator Digital Communicator can be configured for DACT or UDACT mode of operation Configurable via the front panel, PC Configurator, or remote dial up through the built-in modem Sensors can be configured asAlarm, VerifiedAlarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only Modules can be configured as Alarm, Latching Supervisory, Non-Latching Supervisory, Water Flow, Monitor, Trouble, Fire Drill Switch, Signal Silence Switch, Aux Disconnect Switch and Buzzer Silence Switch Base panel is equipped with Four Class "B" (Style "B' indicating circuits which may be configured as Class "A" (Style "Z') using a Class "A" signal converter module Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test Subsequent,AJarm, Supervisory, and Trouble operation RS-485 Interface for Remote LED and LCD Annunciators, Interface for a Remote Trouble Indicator (RTI-1) Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events 5.5 Amp Power Supply Optional modules for additional internal relay circuits and City Tie/Polarity Reversal Optional trim rings for semi-flush mounting ®$MEA approved S7010 7165-1477:156 313-97-E CATALOG NUMBER NOT IC BE USED FOR INSTALLATION PURPOSES. 30(U Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontin u e m o d e l s . FX-350 Series Installation and Operation Manual Appendix C: Specifications FX-3501351 Series Fire Control Panel Digital signal processor based design, fully configurable from front panel with password protection Electrical ratings AC line voltage 120VAC 60Hz/240VAC 50Hz, iDA slow blow fuse on secondary of transformer Power supply rating 5.5 Amp maximum (secondary of transformer) Battery Type 24VDC Gel Cell/Sealed lead acid - 10AH to 24AH Charging capability 10AH to 24AH Protection IOA on board (Fl) slow blow micro fuse Addressable loop One analog loop capable of addressing 126 Mircom addressable devices. Power Limited 37VDC/400mA, maximum loop resistance depends on number of devices and device type. Indicating Circuits 4 supervised style V (Class B) indicating circuits, configured as strobes or audibles. Terminals are labelled as "SIG 1", "SIG 2", "SIG 3" and "SIG 4" Rating Power limited / Regulated 24VDC FWR / 1.7A © 49C per circuit Max power allowed 5A 17A (aux power unfiltered if used) 0.5A (aux power fiItered if used) 0.3A (resettable auxiliary power if used) If no auxiliaries are used the max power is 5A for the indicating circuits Aux supply resettable power limited / 21.1 Vdc regulated / 500mA max Resettable Auxiliary Power (Aux 2) Power limited/21. 1 VDC regulated / 300mA max Unfiltered supply Power limited / Regulated 24VDC FWR / 1 .7A max at 49C Auxiliary relays Common Alarm/Supv.ffrouble/Auxiliary Alarm Must be connected to a listed power limited source of supply Form C/28VDC/1A max RS-485 port For remote annunciators. Terminals are labelled "RS-485". OCAC-304 Output Class A Converter Module Standby OmA I alarm OmA RAM-2081216 Zone Remote Annunciator Standby 35mA / alarm 9OmA RAM-300LCD LCD Remote Annunciator Standby 16mA /alarm 40mA RTI - Remote Trouble Indicator Standby 35mA /alarm 35mA PR-300 - Polarity Reversal and City Tie Module City Tie power limited/ 24VDC unfiltered / 25OmA max /140hms trip coil Polarity Reversal power limited/24VDC open / I2VDC at 3.5mA /8.5mA max (shorted) Polarity Reversal Supv. Terminal 24VDC (normal) /-24VDC (supervisory) /OV (trouble) Polarity Reversal Alarm Terminal 24VDC (normal) / -24VDC (alarm) / OV (trouble) Current Consumption standby 5OmA / alarm 300mA (city tie in use) / alarm 70mA (city tie not in use) 41 Appendix 0: Power Supply and Battery Calculations Appendix D: Power Supply and Battery Calculations POWER REQUIREMENTS (ALL CURRENTS ARE IN AMPERES) Model Number Description Qty STANDBY TOTAL 1 ALARM TOTAL STANDBY ALARM FX-350-60-R/ Main Panel X 0.200 = 0.370 = FX-350-1 26-R FX-350-60-DR/ Main Panel clw Dialer X 0.220 = 0.380 = FX-350-1 26-DR FX-351-LW Main Panel c/wl RAX- X 0.210 = 0.390 (Note 1) = 332 LED Displays - Main Panel, c/wj. RAX- - FX-351-LDW 332 LED Displays and X 0.230 = 0.400 (Note 1) = Dialer RAX-332 32 LED Display - X 0.005 0.010 PR-300 Polarity Reversal and x 0.050 = 0.300 = City Tie Module RAM-300- Remote LCD X 0.016 = 0.040 = LCDW/R Annunciator 11 RAM-208/216 Remote Annunciator, 8 - x 0.0350 = 0.090 = Zone LED RTI-1 Remote Trouble x 0.035 = 0.035 = Indicator MIX-3000 Ionization Detector X 0.00028 = 0.00028 = MIX-3100 Photoelectric Detector X 0.00034 = 0.00034 = MIX-3200 Multi-sensor Detector X 0.00047 = 0.00047 MIX-3300 Heat Detector X 0.00025 = 0.00025 = MIX-lOOP Priority Monitor Module x 0.00060 = 0.00060 = MIX-1O1P Mini Priority Monitor x 0.00060 = 0.00060 = Module 55000-820 Relay Output Module X 0.00085 = 0.00085 = MIX-100S Supervised Control x 0.00100 = 0.00100 = Module MIX-i OOX (Kit) 100XH (Isolator) Isolator c/wMounting x 0.000035 = 0.000035 = Base IOOXB (Base) MIX-2001R Relay Base X 0002 = 0.000040 = Device & Remote LEDs (Maximum 30) x I 0.0040 = Signal Load (bells, horns, strobes, and etc.) - x OS = Auxiliary Power Supply for Annunciators, etc. (See Note 2) I = Total currents (Add above currents) TANDB ALARM (B) continued on next page 42 MS-7lolDu lnteligent Addressable Dual Action Manual Station ALPHA INTELLIGENT ADDRESSABLE MANUAL STATIONS MS-700IDU SERIES MS-701IDU Intelligent Addressable Single Action Manual Staticji Description Mircom's MS-7001DU Series provide manua fire reporting. These, high quality, die-cast meta intelligent Fire Alarm Manual Stations are available In either single or dual action configurations with a permanently attached addressable module. The MS-7001DU Series stations are available a single or dual-action devices with key resets anc a permanently attached addressable module The addressable manual station has DIP switches which allow for address settrg. Pulling the handle initiates the operation of the acdressable module. All models are available with CAT-30 keys and mount on a standard single gang backbox, Mircom model BB-700 interior surface metal backbox, or BB-700WF weather proof backbox. Operation The MS-7011DU Single Action Intelligent Manual Station is operated by pulling down the handle markec. 'PULL HANDLE" on the front of the station. The MS-71 OIDU Dual Actior Intelligent Manual Station is perated by pushing the bar labelled "PUSH BAR' nd tnen pulling down the handle marked "PULL :-IANDLE" The MS-flJlDU Series Manual Stations are reset by opening ti9 station with the key, placing the handle in the normal upright position and re- locking the station. Features Single or Dual Action Key resettable Permanently Attached Intelligent Addressable Module High-gloss red enamel finish Plastic breakrod Meets ADA 5 lb. maximum manual-force Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox Specifications The manual station shall be Mircom's MS-7001DU Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the intelligent addressable module. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. 0 @ @ 7150-1477:128 S7005 S7005 CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any me without notice in prices, colours, ma:erials, components, equipment, specifications and models and also to discontinue models. Specifications Switch Rating: Manual Station Dimensions: Color: I Amp @ 30 VDC 0.1 Amp @ 125 VAC 4.9" H x 3.5W x 2.0" D Red with raised white letters, white Manual bar with raised red letters. Surface Mount Backboxes BB-700 Surface Mount Backbox Dimensions: 5' H x 3.6"W x 2.0" D BB-700WP Weatherproof Surface Mount Backbox Dimensions: 5"H x 3.6W x2.2"D Typical Wiring Diagram MS-7011DU and MS-7101DU r SE__ FROM PREVIOUS DEVICE h __________________________________________ } TO NEXT DEVICE BLACK 181K "•— BLK '"—Lot I lirli i1 RED1 ______ RED L J I> I 0 IL..JI LJ l ADDRESSABLE MODULE + RED PUll Pue WHI z N.O. KEY SWITCH SWITCH - - Ordering Information jiQrL, :- lv-: - MS-701lDU Alpha Intelligent Addressable Key Resettable Single Action Manual Station MS-7101DU Alpha Intelligent Addressable Key Resettable Dual Action Manual Station BB-700 Series 700 Interior Surface Mount Backbox, Red Finish BB-700WP I Series 700 Weatherproof Surface Mount Backbox, Red Finish NOT TO BE USED FOR INSTALLATION PURPOSES. M1RcQr!r Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Distributed by: Web page: http://www.mircom.com Email: mail@mircom.com ISO 9001:2000 REGISTERED CAT. 5879 Rev. 0 ALPHA INTELLIGENT ADDRESSABLE DETECTORS MIX-3000 SERIES MIX-3000 MIX-3100 Ionization Smoke Detector Photoelectric Smoke Detector Features Low profile design For use with the FX-350 Series Fire Alarm Control Panels Fast response time Automatic addressing with the MIX-ADD card Variety of mounting bases Ease of installation Elegant, unobtrusive design Digital communications MIX-3200 MIX-3300 Multi-Sensor Detector Thermal Detector Description Mircom's Alpha Series Intelligent Addressable Detectors are designed to meet a wide range of applications. The detectors address is set in its base providing a convenient and trouble free maintenance procedure. The detectors mount into a selection of base styles to accommodate installation requirements. Intelligent Ionization Smoke Detector (MIX-3000) The Ionization smoke detector incorporates a unique dual chamber design to respond quickly and dependably to a broad range of fires. The ionization detector is equipped with a red LED which flashes when the detector is polled and turns on steady when the detector goes into alarm. (UL Listed) Intelligent Multi-Sensor Detector (MIX-3200) The Intelligent Multi-Sensor Detector is a photoelectric smoke detector with a supplementary thermal sensor. The Multi-Sensor detector combines photoelectric smoke and thermal sensor values to provide enhanced detection performance and reduction of false alarms. Information from each sensing element is processed and conditioned by an on-board advanced technology ASIC and digitally transmitted to the FACP as a single analog value comprised of the combined responses from both the photoelectric smoke and thermal detection elements. Intelligent Thermal Detector (MIX-3300) The Intelligent Thermal Detector utilizes state of the art electronic temperature sense to provide fast and accurate temperature monitoring. The thermal detector features an adjustable termperature range that is configured from the FX-350 Series fire alarm control panel. Intelligent Photoelectric Smoke Detector (MIX-3100) The Intelligent photoelectric smoke sensor utilizes a unique optical sensing chamber that is designed to sense smoke produced by a wide range of combustion sources. The photoelectric detector is equipped with a clear LED which flashes when S6295 S6965 the detector is polled and turns on steady when the 7271-1477138 (MIX-3000 MIX-3100 (MIX-3100 M.3J & detector goes into alarm. 72,2 !X -1477 O) 131 MIX-3200) & MIX-3200) AIX.3100) S6299 S7498 .1477:142 (MIX-3300) (MIX-3300) (MIX.3 200) (MIX-3300) 7270-1477:139 CATALOG NUMBER 5676 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. MIX-ADD Address Card A unique, patented addressing method provides simple, user friendly and accurate identification of the detector location. A coded MIX-ADD card is inserted in the base. This can then be read by any Alpha Series detector once it is plugged in. Using this method, all the electronic components are in the detector but the location information is held in the base. The MIX-ADD card simplifies and speeds up installation and commissioning. Addressing errors during maintenance and service are eliminated. Specifications General Specifications 16-28 VDC Class A (Style 0) or Class B (Style B) i Communcaton. switch selectable LRe 0% to 95% (No condensation or icing) MIX-3000 Ionization Detector 280 pA 4 mA MIX-3100 Photoelectic Detector 340 pA PU 4 mA Ordering Information 0°F to +155°F (-20°C to +70°C) jemperature White Polycarbonate MIX-3200 Multi-Sensor Detector 470 pA 4 mA MIX-3300 Thermal Detector 250 pA TAD Current 4 mA Operating 131 F to 194'F (55 *C to 90'C) Temperature _Range escr MIX-3000 Intelligent Addressable Ionization Smoke Detector (UL Listed) MIX-3100 Intelligent Addressable Photoelectric Smoke Detector MIX-3200 Intelligent Addressable Multi-Sensor Detector MIX-3300 Intelligent Addressable Thermal Detector MIX-ADD Address Card for MIX-3000 Series Intelligent Detectors NOT TO BE USED FOR INSTALLATION PURPOSES. 11111k, RIK O.M Distributed by: Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates Vaughan, Ontario L4K 5W3 Niagara Falls, NY 14305 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mailimircom.com ISO 9001:2000 REGISTERED ¶$7 CAT. 5676 Rev. 0 ALPHA INTELLIGENT ADDRESSABLE MODULES MIX-100 SERIES MIX-101P MIX-1 OOP MIX-100S MIX-1 OOX Description Mircom's Alpha Series Intelligent Addressable Modules are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterflow switches, conventional smoke detectors and more. An eight position dip switch allows for the address setting of fie device and the wiring class/style of the devices that are connected to the medule. All modules mount in a standard 4" x 4" x 2 118" junction box. Intelligent Addressable Priority Monitor Module (MIX-lOOP) The Intelligent Addressable Priority Monitor Module (MIX-lOOP) provides an address for a group of UL/ ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4- wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-100P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-100P has an activated red LED. Features Designed to meet a wide range of applications For use with the FX-350 Series Fire Alarm Control Panels Fast response time Priority Interrupt feature on monitor modules Monitor modules can be wired as a Class A (Style D) or Class B (Style B) Each module can be addressed from 1 t 126 Eight position dip switch for address setting Red light indicator Modules mount in standard 4" junction box Intelligent Addressable Priority Mini-Monitor Module (MIX-101P) The Intelligent Addressable Priority Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style 0) or Class B (Style B) initiating circuit. The MIX-1 01 P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-101P has an activated red LED. Intelligent Addressable Single Relay Output Module (55000-820) The Intelligent Addressable Single Relay Output Module connects to the same loop as the initiating devices and provides one Form-C contact to control a variety of normally open or normally closed contact applications cuch as fan operation and door closures. 0 & @ S5434 S5434 7150-1477:156 CATALOG NUMBER 5675 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at aiy time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Intelligent Addressable Supervised Control Module (MIX-100S) The MIX-100S Control module provides supervised monitoring of wiring to signal devices that require an external power supply to operate, such as horns, strobes, bells or speaker isolators. Conventional signals will require a 24 VDC power source and speakers will require an audio input. The red LED will illuminate when the module is activated. The module is capable of Class A (Style Z) or Class B (Style Y) supervision. Specifications General Specifications OportingVoftag 16-28 VDC - Class A (Style D) or Class B (Style B) switch selectable tR!ve Humlaity 0% to 95% (No condensation or icing) MIX-100P and MIX-101P Ctirren?inhiirnptwn . 600 pA Aiarmçurrent. . 4 mA (LED on MIX-100P 4.0" W x 4.0" H x 1.3" D ns ions" RMI MIX-101P 3.0"Wx2.0"Hx0.75"D MIX-1 OOP 3.0 oz. (85.8g) Wolght - ......... MIX-101P 1 1.5 02. (42.6g.) -L Fault Isolator Module (MIX-100X) The MIX-i OOX Fault Isolator Module is used to protect the system against wire-to-wire short circuits on the analog loop. The modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop. In the event of a short circuit between any two fault isolator modules, both modules immediately switch to an open circuit condition and isolate any group of sensors between them. The remaining units on the circuit will continue to operate in a normal fashion (must be wired in Class A or Style 6). [ p.ratlng 0"F to +155°F (-20°C to +70°C) .Te'prturo. --_v ---. HousIngiCovór ih White Polycarbonate MIX-100X Cu'eiit,çoiiumption 35pA at 24V -. - . lAmp UncRcscstance -- 0.2 ohm bimensioiis . 4.0W x 4.0" H x 1.3" D 3.0 oz. (85.89) MIX-100S Cur'reipnsumption 1 mA - Signals 24 VDC regulated ce Speakers 70.7 V RMS atI,ig's. 2A@ 30VDC. 0.6A@ I25VAC Iiohs. " 4.0"Wx4.0'Hx1.3"D 3.0 oz. (85.8g) Ordering Information del4LAescriptIon -7 , MIX-loop Intelligent Addressable Priority Monitor Module MIX-i 01 P Intelligent Addressable Priority Mini Monitor Module MIX-lOGS Intelligent Addressable Supervised Control Module MIX-i OOX Fault Isolator Module 55000-820 Intelligent Addressable Single Relay Output Module NOT TO BE USED FOR INSTALLATION PURPOSES. Distributed by: Canada 25 Interchange Way Vaughan, Ontario L41< 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 Web page: http://www.mircom.com U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Email: mail@mircom.com ISO 9001:2000 REGISTERED WE CAT. 5675 Rev, 0 UL Max. Current 115cd 177cd Nigh (95) dBA 0.350 0.477 Low (90) dBA 0.306 0.429 UL Max. Current Audible 24 VDC I2 VDC High (95) dBA 0.044 0.021 Low (90) dBA 0.018 0.01T- Wall Mount Strobes UL Max. Current 15cd 30cd 75cd llocd ZRS-MCW-FR Red 4085 24 VDC 0.060 0.092 0.165 0.220 ZRS-MCW-FW White 0302 ZRS-MCWH-FR Red 5242 ZRS-MCWH-FW White 0303 UL Max. Current 135cd 185cd Ceiling Mount Strobes 24VD6o.300 20 ZRS-MCC-FW White 0309 ZRS-MCC-FR Red 0308 UL Max. Current 15cd 30cd 75cd 95cd ZRS-MCCH-FW White 0314 24 VDC 0.065 0.105 0.189 0.249 ZRS-MCCH-FR Red 5240 - ULMax. Current 115cd 177cd 24 VDC 0.300 0.420 Horns and Horn Strobes Wail or Ceiling Mount Horn ZNH-R Red 0300 ZNH-W White 0301 Wail Mount Horn Strobe ZNS-MCW-FR Red 0304 ZNS-MCW-FW White 0305 ZNS-MCWH-FR Red 0306 ZNS-MCWH-FW White 0307 Ceiling Mount Horn Strobe ZNS-MCC-FW White 0311 ZNS-MCC-FR Red 0310 ZNS-MCCH-FW White 0313 ZNS-MCCH-FR Red 0312 uL Max. Current 15cd 30cd 75cd llocd High(95)dBA 24 VDC 0.074 0.107 0.184 0.244 Low(90)dBA 24 VDC 0.066 0.101 0.177 0.232 UL Max. Current 115cd 30cd 75cd 95cd High (95) dBA 24 VDC 0.082 0.124 0.209 0.275 Low (90) dBA 24 VDC 0.071 0.114 0.201 0.261 (800) 631-2148 vmw.cooperwheelock.com Features an easy snap on base to simplify the installation and strobes horns and horn strobes designed es testing of CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No 7165-1477:156 Page 1 of 2 CATEGORY: Control Unit (Non High-Rise) LISTEE: Mircom Technologies Ltd., 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Models FX-350-60-R, FX-350-60-DR, FX-350-126-R, FX-350-126-DR, FX-35 1-LW and FX-351-LDW fire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU), waterflow and sprinkler supervisory services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: MO-815 FX-350/FX-351 Mainboard - with Dialer MD-837 FX-350/FX-351 Mainboard - No Dialer MD-749 DSP Core Board MD-819 Power Supply Board PR-300 City Tie/Polarity Reversal TR-061 120/240 VAC Transformer CH-613 FX-350 Backbox CH-641 FX-350 Door CH-642 FX-350 Deadfront CH-643 FX-351 Deadfront CH-644 FX-351 Door CH-645 FX-351 Backbox MD-825 RAX 232 RAM-300-LCD Remote LCD Annunciator MIX-3000 Addressable Ion Smoke Detector (CSFM# 7271-1477:138) MIX-3100 Addressable Photoelectric Smoke Detector (CSFM# 7272-1477:131) MIX-3200 Addressable Photo/Heat Detector (CSFM# 7272-1477:142) MIX-3300 Addressable Heat Detector (CSFM# 7270-1477:139) MIX-2000-2001 Standard Base (CSFM# 7300-1477:145) MIX-2001R Standard Base with Relay (CSFM# 7300-1477:145) MIX-lOOP Priority Monitor Module MIX-101P Mini Priority Monitory Module MIX-100S Supervised Control Module MIX-bOX Isolator Kit RATING: 120 VAC, 60Hz 240 VAC, 50 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Page 2 of 2 7165-1477:156 APPROVAL: Listed as fire alarm control units for use with listee's separately listed electrically and functionally compatible initiating and indicating devices as indicated in design. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. This control panel meets the requirements of UL-864, 90' Edition. 05-23-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results l IJJ and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation LL..JJ criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 24, 2009 Listing Expires June 30, 2010 Authorized By., FRANCIS MATEQ, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS lISTING PROGRAM LISTING SERVICE LISTING No. 7150-1477:128 Page 1 of I CATEGORY: LISTEE: Fire Alarm Pull Boxes Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 mcherubin@mircom. com* DESIGN: Models MS-701 U, -703U, 704U, -71 OU, -713U, -714U, 701ADU, -71OADU, -702U, -702ADU, -701UP, -710UP, -703U(C), -704U(C), -713U(C), -714U(C), -705U, -715U,-706U(C), - 716U(C), -707U(C), -717U(C) and -708 fire alarm boxes. These devices are manually actuated, single or dual action non-coded, fire alarm boxes. Units are to be mounted on standard outlet boxes or listee's Model BB-700 backbox for indoor use only and BB-700WP backbox for indoor and outdoor use. Models MS- 701 ID(U), -7021D(U) and -7101D(U) non-coded, indoor use only, fire alarm boxes. To be mounted on three-inch deep outlet boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC, 1A, 125 VAC, 1A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm control units. Refer to listee's Installation instruction Manual for details. * This manual pull box does not meet the requirements of UL Standard 38, 1999 Edition with California amendments. *updated 01-28-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JANUARY 28, 2010 Listing Expires June 30, 2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIAlS LISTING PROGRAM LTSTTNG SERVICE CAL 1 FIRE LISTING No. 7272-1477:131 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Model MIX-31 00 photoelectric smoke detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 17 to 28 VDC, 5 to 9V protocol INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with listee's separately listed compatable fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. 7300-1477:145). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen XLF: 7272-1394:104 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 1 recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No 7270-1477:139 Page 1 of I CATEGORY: Heat Detector LISTEE DESIGN: RATING: INSTALLATION MARKING: APPROVAL: XLF: Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 Model MIX-3300 combination electronic/fixed temperature heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. Fixed Temperature: 1310 -194°F Electrical: 17 to 28 VDC, 5 to 9 V protocol In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as a heat detector for use with listee's separately listed compatible fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. 7300-1477:145). Refer to listee's Installation Instruction Manual for details. 7270-1394:105 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ";'+ recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1394:108 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Apollo Fire Detectors Ltd, 36 Brookside Road, Havant, Hampshire, P09 1JR, England Contact: Gordon Ash +44(0)23 9249 2412 FAX +44(0)23 9249 2754 DESIGN: XP95A analog addressable signaling/contact monitoring modules. Model 55000-805 switch monitor module, Model 55000-806 priority switch monitor module, Model 55000- 820 switch monitor input-output module, Model 55000-825 sounder control module, Model 55000-830 mini priority switch monitor module and Model 55000-831 mini switch monitor module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 17 to 28 VDC, 5 to 9 V protocol INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as monitoring modules for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 06-20-03KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or '• recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2009 Listing Expires June 30, 2010 Authorized By. FRANCIS MA TEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:142 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 deborah.piserchia©coopeiwhcelock.com DESIGN: Models NH-12124, NH-12124R, and ZNH horns and Models NS-1215W, NS-121575W, NS-2415W, NS-241575W, NS-2430W, NS-2475W and NS-24110W; NS4-1215W, NS4- 121575W, NS4-24 15W, NS4-24 1575W, NS4-2430W, NS4-2475W and NS4-24 110W, NS-24MCW, NS4-24MCW, NS-24MCC, NS-24MCCH, ZNS-MCW, ZNS-MCC, ZNS- MCWH and ZNS-MCCH horn strobes. Model number may be followed by any two- alpha/numeric characters indicating lens, lettering and color. Units are synchronized or non-synchronized strobes. Models NH-12/24R, NS-24MCC, NS-24MCCH, ZNS-MCC and ZNS-MCCH are ceiling mount only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical-Strobe Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Candela: 15=15cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=llocd (Wall) NS-24MCW, NS4-24MCW, ZNS-MCW: Selectable 15cd, 30cd, 75cd, 110cd NS-24MCC, ZNS-MCC: Selectable 15cd, 30cd, 75cd, 95cd NS-24MCCH, ZNS-MCCH: Selectable llscd, 177cd ZNS-MCWH: Selectable 135cd, 185cd Flash rate: 60 Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. All units are for wall mount except for *Models NH.-12/24R, NS-24MCC, NS-24MCCH, ZNS-MCC and ZNS-MCCH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only except for model NH-12/24 horn. All synchronization strobes shall be used with Models SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132). Refer to manufacturer's installation manual for details. NOTE: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Correed 07-25-08 bh Lt: This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By. FRANCIS MA TEO, Program Coordinator Fire Engineering Division