No preview available
HomeMy WebLinkAbout2006 COSTA DEL MAR RD; ; AS05027510/6/2020 AS050275 Permit Data City of Carlsbad Sprinkler Permit 2006 COSTA DEL Job Address: MAR RD Permit Type: SPRINK Parcel No: 2166100201 Lot #: 0 Reference No.: PC #: Permit No: AS050275 Status: ISSUED Applied 12/30/2005 Approved: 1/6/2006 Issued: 1/6/2006 Inspector: Project Title: LA COSTA RESORT, BLDG. 2 FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA, -W1 El El I Fees ($) Add'I Fees ($) Total ($) Balance ($) 2,280 0 2,280 0 1/1 Asoeyo~~S_ c hydrauhc:calculations Page 1 '2dflbór'4hEàd unit Date 113005 HYDRAULIC DESIGN INFORMATION SHEET Name - La Costa Resort and Spa Date - Location - 2006 Costa Del Mar Rd Carlsbad Building - Building Two 2nd FLOOR LIVING UNIT System No. - 2ND floor UNIT Contractor - Cosco Fire Protection Inc Contract No. - 10CB-0206 Calculated By - PG Drawing No. - FP3 Construction: (xx) Combustible ( ) Non-Combustible Ceiling Height 9' OCCUPANCY - Residential S Type of Calculation: ( x)NFPA 13 Residential (x)NFPA 13R ( )NFPA 13D Y Number of Sprinklers Flowing: ( )1 ( )2 (x)4 S )Other T )Specific Ruling Made by Date E M Listed Flow at Start Point - 17 Gpm System Type Listed Pres. at Start Point - 12 Psi (x) Wet C ) Dry D MAXIMUM LISTED SPACING 18 x 18 Deluge C ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - 100 Gpm Make tyco Model LFII I Elevation at Highest Outlet - Feet Size K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 76.25 Psi Required 71.75 Summary C-Factor Used: Overhead 150 W Water Flow Test: Pump Data: A Date of Test - 10-11-04 Rated Cap. T Time of Test - @ Psi E Static (Psi) - 126 Elev. R Residual (Psi) - 109 Other Flow (Gpm) - 3000 S Elevation - 40 P Location: ESTRELLA DEL MAR P L Source of Information MDS CONSULTING Y At Test Underground 150 Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm VVdLI OUI4)Iy %.,Ul VC I.4 hydraulic calculations Page 2 2nd floor 4 head unit Date 113005 City Water Supply: Demand: Cl - Static Pressure : 126 Dl - Elevation : 10.827 C2 - Residual Pressure: 109 D2 - System Flow : 76.249 stem Pressure : 86.791 HoseAdj City) C2 - Residual Flow : 3000 D2 - S ~Demancf) Hose : 100 D3 - System Demand : 176.249 Safety Margin : 39.120 150 140 130 : !± p120_ R11° E10° S 90 S 80 U 70 R6° E5° 40 30 20 10 --1- -.--. 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (NA 1.85) C2 Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 ILLIIIb USU oUlluhidly hydraulic calculations Page 3 2nd floor 4 head unit • Date 113005 Fitting Legend Abbrev. Name ½ ~ 1 1% 1% 2 2% 3 3½ 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45' Elbow I I 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90' Flow lhruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zfa Febco 826YD Fitting generates a Fixed Loss Based on Flow Computer Proarams by Hvdratec Inc. Route 111 Windham N.H.. USA 03087 Pressure / Flow Summary - STANDARD hydraulic calculations Page 4 2nd floor 4 head unit Date 113005 Node No. Elevation K-Fact Pt Actual Pn Flow Density Area Press Actual Req. DIOI 25.5 4.9 12.05 na 17.01 0.0525 324 12.0 1 65.0 K= K @ EQOI 12.61 na 17.01 3 65.0 K= K @ EQOI 13.07 na 17.32 5 65.0 K= K @ EQ01 16.37 na 19.38 7 65.0 K = K @ EQOI 22.14 na 22.54 2 65.0 13.91 na 4 65.0 17.34 na 6 65.0 23.12 na 8 65.0 33.39 na 23 65.0 40.71 na TOR 65.0 60.54 na BOR 46.0 71.15 na Dl 42.5 72.77 na BI 42.0 73.13 na B2 42.0 73.18 na B3 42.0 85.87 na B4 42.0 85.9 na S 40.0 86.79 na 100.0 The maximum velocity is 18.1 and it occurs in the pipe between nodes 4 and 6 Final Calculations - Hazen-Williams hydraulic calculations Page 5 2nd floor 4 head unit Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn DIOI 17.01 1.101 IT 6.328 1.000 12.051 K Factor = 4.90 to 120 0.0 6.328 0.0 EQOI 17.01 0.0761 0.0 7.328 0.558 Vel = 5.73 0.0 17.01 12.609 K Factor = 4.79 1 17.01 1.101 2E 7.65 8.600 12.609 K Factor © node EQOI to 150 IT 9.563 17.213 0.0 2 17.01 0.0504 0.0 25.813 1.302 Vel = 5.73 0.0 17.01 13.911 K Factor = 4.56 3 17.32 1.101 IT 9.563 6.500 13.073 K Factor © node EQOI to 150 0.0 9.563 0.0 2 17.32 0.0522 0.0 16.063 0.838 Vel = 5.84 0.0 17.32 13.911 K Factor = 4.64 5 19.38 1.101 IT 9.563 5.600 16.369 K Factor © node EQOI to 150 0.0 9.563 0.0 4 19.38 0.0642 0.0 15.163 0.974 Vel = 6.53 0.0 19.38 17.343 K Factor = 4.65 7 22.54 1.101 IT 9.563 2.080 22.136 K Factor @ node EQOI to 150 0.0 9.563 0.0 6 22.54 0.0849 0.0 11.643 0.988 Vel = 7.60 0.0 22.54 23.124 KFactor= 4.69 2 34.33 1,101 IT 9.563 9.000 13.911 to 150 0.0 9.563 0.0 4 34.33 0.1849 0.0 18.563 3.432 Vel = 11.57 4 19.38 1.101 IT 9.563 4.100 17.343 to 150 0.0 9.563 0.0 6 53.71 0.4231 0.0 13.663 5.781 Vel = 18.10 6 22.54 1.394 21 19.046 21.000 23.124 to 150 0.0 19.046 0.0 8 76.25 0.2564 0.0 40.046 10.268 Vel = 16.03 8 0.0 1.394 2E 9.523 19.000 33.392 to 150 0.0 9.523 0.0 23 76.25 02564 0.0 28.523 7.314 Vel = 16.03 23 0.0 1.598 3E 17.484 98.000 40.706 to 150 31 34.968 52.452 0.0 TOR 76.25 0.1318 0.0 150.452 19.837 Vel = 12.20 Final Calculations - Standard hydraulic calculations Page 6 2nd floor 4 head unit Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ***** Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Pn TOR 0.0 2.157 0.0 19.000 60.543 to 120 0.0 0.0 9.729 * Fixed loss = 1.5 BOR 76.25 0.0462 0.0 19.000 0.878 Vet = 6.69 BOR 0.0 4.1 2E 29.067 40.000 71.150 to 140 0.0 29.067 1.516 Dl 76.25 0.0015 0.0 69.067 0.106 Vel = 1.85 Dl 0.0 4.07 IF 6.373 77.000 72.772 to 150 IE 15.932 22.305 0.217 61 76.25 0.0014 0.0 99.305 0.137 Vet = 1.88 BI 0.0 4.1 IT 29.067 5.500 73.126 to 140 0.0 29.067 0.0 B2 76.25 0.0015 0.0 34.567 0.053 Vet = 1.85 B2 0.0 4.1 IE 14.534 5.000 73.179 to 140 lZfa 0.0 14.534 12.661 83 76.25 0.0015 0.0 19.534 0.030 Vel = 1.85 B3 0.0 4.1 IE 14.534 5.500 85.870 to 140 0.0 14.534 0.0 B4 76.25 0.0015 0.0 20.034 0.030 Vet = 1.85 B4 0.0 5.86 IG 3.834 60.000 85.900 to 150 IT 38.342 42.177 0.866 S 76.25 0.0002 0.0 102.177 0.025 Vet = 0.91 100.00 Qa= 100.00 176.25 86.791 KFactor= 18.92 ~FA~ Tjt1=.1.M - - - Fire Protection by Computer Desig n COSCO FIRE PROTECTION 10695 TREENA STREET SUITE 105 CARLSBAD, CA 92131 858 444-2000 Job Name 2nd floor 4 Building : BLD 2 2nd FLOOR. Location : 2006 Costa Del Mai R d J C a r I s b I System : 2ndfIoorCORR Contract : IOCB-0206 Data File : LCRV 2wx2 F ; Z 44 Computer Programs by Hydratec Inc. R o u t e 111 Windham N.H. USA 03087 El Most Protection Design S Ccsung rith. Comments Date tOSCO FIRE PROTECTION Page 1 2nd floor 4 head CORRIDOR Date 113005 HYDRAULIC DESIGN INFORMAT I O N S H E E T Name - La Costa Resort and Spa Date - Location - 2006 Costa Del Mar Rd Carlsbad Building - BLD 2 2nd FLOOR CORRIDOR System No. - 2nd floor CORR Contractor - Cosco Fire Protection Inc Contract No. - IOCB-0206 Calculated By - PG Drawing No. - FP3 Construction: (xx) Combustible ( ) Non-Combustible Ceiling Height 9' OCCUPANCY - Residential S Type of Calculation: ( x)NFPA 13 Residential (x)NFPA 13R ( )NFPA 13D Y Number of Sprinklers Flowing : C )l ( )2 (x)4 S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 21 Gpm System Type Listed Pres. at Start Poin t - 25 Psi (x) Wet C ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - 100 Gpm Make tyco Model LFII HSW I Elevation at Highest Outlet - Feet Size K-Factor 4.2 G Note: Temperature Rating 155 N Calculation Gpm Required 86 . 6 5 Psi Required 74.12 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date, of Test - 5-17-05 Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 113 , Elev. R Residual (Psi) - 105 Other Well Flow (Gpm) - 1234 Proof Flow Gpm S Elevation - 56.33 P Location: ESTRELLA DE L MAR & COSTA DEL MAR P L Source of Information: CO S C O F I R E P R O T E C T I O N / CWD Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 0 3 0 8 7 COSCO FIRE PROTECTION Page 2 2nd floor 4 head CORRIDOR Date 113005 City Water Supply: Demand: Cl - Static Pressure : 113 Dl - Elevation : 3.755 C2 - Residual Pressure: 105 D2 - System Flow : 88.611 stm Pressure : 83.359 C2 - Residual Flow : 1234 D2 - SrAd' Hose j City) ________Hose Demand) : 100 D3 - System Demand : 188.611 Safety Margin : 29.394 150 140 130 p120 C1 R11° E 100 90 IO'odnl u 70 R6° E5° 40 30 20 10 200 400 600 800 1000 .1200 1400 1600 1800 FLOW (N"1.85) Comouter Procirams by Hvdratec Inc. Route 111 Windham N.H. USA 0 3 0 8 7 COSCO FIRE PROTECTION Page 3 - 2nd floor 4 head CORRIDOR Date 113005 Fitting Legend Abbrev. Name % % 1 1% 1V2 2 2'A 3 3V2 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45' Elbow I 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90' Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zfa Febco 826YD Fitting generates a Fixed Loss Based on Flow Comouter Proarams by Hvdratec Inc. Route 111 W i n d h a m N . H . U S A 0 3 0 8 7 I Ii-,Saulu I I Ill VV J UI I SI I Icil y - j I U u.ru LI OSCO FIRE PROTECTION Page 4 2nd floor 4 head CORRIDOR Date 113005 Node Elevation K-Fact Pt Pn Flow Density Area. Press No. Actual Actual Rea. D103 25.5 4.2 25.0 na 21.0 0.082 256 25.0 0105 25.5 4.2 25.0 na 21.0 0.082 256 25.0 EQ21 65.0 4.2 25.0 na 21.0 0.082 256 25.0 EQ20 65.0 4.2 25.22 na 21.09 0.082 256 25.0 20 65.0 26.69 na 21 65.0 31.29 na 8 65.0 31.48 na 22 65.0 K = K @ EQ22 31.53 na 22.18 23 65.0 K = K @ E023 37.05 na 24.34 TOR 65.0 63.24 na BOR 46.0 74.13 na Dl 42.5 75.78 na BI 42.0 76.18 na B2 42.0 76.25 na B3 42.0 89.19 na B4 42.0 89.23 na S 40.0 90.13 na 100.0 J 56.33 83.34 na TEST 56.33 83.36 na The maximum velocity is 14.18 and it occurs i n t h e p i p e b e t w e e n n o d e s 2 0 a n d 2 1 Computer Programs by Hydratec Inc. Route 1 1 1 L Windham N.H. USA 03087 I Ii•IcI .,aI.,UIaLnJI io i I0L.I i vv 111101110 COSCO FIRE PROTECTION Page 5 2nd floor 4 head CORRIDOR Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn D103 21.00 1.101 4E 10.126 12.500 26.000 K Factor = 4.20 to 120 IT 6.328 16.454 0.0 EQ22 21.0 0.1125 0.0 28.954 3.258 Vet = 7.08 0.0 21.00 28.258 K Factor = 3.95 0105 21.00 1.101 4E 10.126 6.500 25.000 K Factor =4.20 to 120 IT 6.328 16.454 0.0 EQ23 21.0 0.1125 0.0 22.954 2.583 Vet = 7.08 0.0 21.00 . 27.583 K Factor = 4.00 EQ2I 21.00 1.101 2E 7.65 5.500 25.000 K Factor = 4.20 to 150 IT 9.563 17.213 0.0 20 21.0 0.0745 0.0 .22.713 1.691 Vet = 7.08 0.0 21.00 26.691 K Factor = 4.06 EQ20 21.09 1.101 2E 7.65 2.400 25.219 K Factor =4.20 to 150 IT 9.563 17.213 0.0 20 21.09 0.0751 0.0 19.613 1.472 Vet = 7.11 20 21.00 1.101 IT 9.563 7.500 26.691 to 150 0.0 9.563 0.0 21 42.09 0.2695 0.0 17.063 4.599 Vet = 14.18 21 0.0 1.394 0.0 2.200 31.290 to 150 0.0 .0.0 0.0 8 42.09 0.0855 0.0 2.200 0.188 Vet = 8.85 8 0.0 1.394 0.0 0.580 31.478 to 150 0.0 0.0 . 0.0 22 42.09 0.0862 0.0 0.580 0.050 Vet = 8.85 22 22.18 1.394 2E 9.523 20.000 31.528 K Factor @ node EQ22 to 150 0.0 9.523 0.0 23 64.27 0.1869 0.0 . 29.523 5.519 Vet = 13.51 23 24.34 1.598 3E 17.484 98.000 37.047 K Factor © node EQ23 to 150 3T 34.968 52.452 0.0 TOR 88.61 0.1741 0.0 150.452 26.194 Vet = 14.17 TOR 0.0 2.157 0.0 19.000 63.241 to 120 0.0 0.0 9.729 * Fixed loss = 1.5 BOR 88.61 0.0610 0.0 19.000 1.159 Vet = 7.78 BOR 0.0 4.1 . 2E 29.067 40.000 74.129 to 140 0.0 29.067 1.516 DI 88.61 0.0020 0.0 69.067 0.139 Vet = 2.15 Dl 0.0 4.07 IF 6.373 77.000 75.784 o 150 IE 15.932 22.305 0.217 BI 88.61 0.0018 0.0 99.305 0.182 Vet = 2.19 Computer Programs by Hydratec Inc. Rout e 111 Windham N.H. USA 03087 i .i•o, .iait,uiouui ,o - ivai u 'COSCO FIRE PROTECTION Page 6 2nd floor 4 head CORRIDOR Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe PV ******* Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Pn Bi to B2 0.0 88.61 4.1 140 0.0020 IT 29.067 0.0 0.0 5.500 29.067 34.567 76.183 0.0 0.069 Vel = 2.15 B2 0.0 4.1 1 14.534 5.000 76.252 to 140 lZfa 0.0 14.534 12.898 B3 88.61 0.0020 0.0 19.534 0.040 Vet = 2.15 B3 0.0 4.1 1 14.534 5.500 89.190 V to 140 0.0 14.534 0.0 V B4 88.61 0.0020 0.0 20.034 0.040 Vet = 2.15 B4 0.0 5.86 to 150 S 88.61 0.0003 S 100.00 5.86 to 150 J 188.61 0.0013 J 0.0' 8.27 to 140 TEST 188.61 0.0003 0.0 188.61 1 3.834 60.000 89.230 IT 38.342 42.177 0.866 0.0 102.177 0.032 VeI= 1.05 2G 7.668 180.000 90.128 Qa = 100 IT 38.342 46.011 -7.073 0.0 226.011 0.285 Vel = 2.24 0.0 '70.000 83.340 0.0 0.0 0.0 V V 0.0 70.000 0.019 Vel = 1.13 83.359 K Factor = 20.66 Computer Programs by Hydratec Inc. R o u t e 1 1 1 W i n d h a m N . H . U S A 0 3 0 8 7 -. Fire Protection by Computer Design COSCO FIRE PROTECTION 10695 TREENA STREET SUITE 105 CARLSBAD, CA 92131 858 444-2000 Job Name : 2nd floor 4 head unit Building : Building Two 2nd FLOOR LIVING UNIT Location : 2006 Costa Del Mar Rd Carlsbad System : 2ND floor UNIT Contract : I OCB-0206 Data File : LCRV 2.wxl Computer Programs by Hydratec Inc. Route 111 Wi n d h a m N . H . U S A 0 3 0 8 7 COSCO FIRE PROTECTION Page 1 .2nd floor head unit Date 113005 HYDRAULIC DESIGN INFORMATION SHEE T Name - La Costa Resort and Spa Date - Location - 2006 Costa Del Mar Rd Carlsbad Building - Building Two 2nd FLOOR LIVING UNIT System No. - 2ND floor UNIT Contractor Cosco Fire Protection I n c Contract No. - 10CB-0206 Calculated By - PG Drawing No. - FP3 Construction: (xx) Combustible ( ) Non-Combustible Ceiling Height 91 OCCUPANCY - Residential Type of Calculation: ( x)NFPA 13 Residential (x)NFPA 13R )NFPA 13D Number of Srinklers Flowing: )1 ( )2 (x)4 )Other )Specific Ruling Made by Date Listed Flow at Start Point - 17 Gpm System Type Listed Pres. at Start Point - 12 Psi (x) Wet ( ) Dry MAXIMUM LISTED SPACING 18 x 18 ( ) Deluge ( ) PreAction Domestic Flow Added - 0 Gpm Sprinkler or Nozzle Additional Flow Added - 100 Gpm Make tyco Model LFII Elevation at Highest Outlet - Feet Size K-Factor 4.9 Note: Temperature Rating 155 Calculation Gpm Required 76.25 Psi Required 71.75 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 5-17-05 Rated. Cap. Cap. T Time of Test - Psi Elev. E Static (Psi) - 113 Elev. R Residual (Psi) - 105 Other Well Flow (Gpm) - 1234 ProofFlow Gpm S Elevation - 40 P Location: ESTRELLA DEL MAR & Costa Del Mar RD P L Source of Information: COSCO F I R E P R O T / CFD FLOW TEST Y S Y S T E M D E S I G N Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 City Water Supply: Cl - Static Pressure : 101.7 C2 - Residual Pressure: 94.5 C2 - Residual Flow :1234 Demand: Dl - Elevation : 3.755 D2 - System Flow : 71.81 : 92.177 D2 - SrAdj sem Pressure Hose City _______Hose Demand) : IQO D3 - System Demand : 171.81 Safety Margin : 9.336 COSCO FIRE PROTECTION Page 2 2nd floor 4 head unit . Date 113005. 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N" 1.851) Comouter Proarams by Hvdratec inc. Route 111 Windham N.H. USA 03087 COSCO FIRE PROTECTION 2nd floor 4 head unit Page 3 Date 113005. Fitting Legend Abbrev. Name 1% 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45' Elbow I 1 1 1 2 2 3 3 3 4 5 7 9 II 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90' Flow lhru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zfa Febco 826YD Fitting generates a Fixed Loss Based on Flow Computer Proorams by Hvdratec Inc. Route 111 Windham N.H. US A 0 3 0 8 7 i ou-,jouiv , i njvv ,u, iii. iai y - J i rud(Jru I.J COSCO FIRE PROTECTION Page 4 2nd floor 4head unit Date 113005 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. D101 64.0 4.9 12.05 na 17.01 1 65.0 K = K @ E001 29.28 na 17.01 3 65.0 K=K©EQ01 29.76 na 17.15 5 65.0 K = K @ EQOI 33.13 na 18.09 7 65.0 K = K c EQO1 38.72 na 19.56 2 65.0 30.59 na 4 65.0 33.99 na 6 65.0 39.48 na 8 65.0 48.67 na 23 65.0 55.21 na TOR 65.0 72.97 na BOR 46.0 83.48 na DI 42.5 85.09 na BI 42.0 85.43 na 82 42.0 85.48 na B3 42.0 98.08 na B4 42.0 98.11 na S 40.0 99.0 na 100.0 J 56.33 92.16 na TEST 56.33 92.18 na 0.0525 324 12.0 The maximum velocity is 17.61 and it occurs in th e p i p e b e t w e e n n o d e s 4 a n d 6 Computer Programs by Hydratec Inc. Route 111 W i n d h a m N . H . U S A 0 3 0 8 7 I IlICH 'JQIjUIQUJI I - I IQi..I IV V IIIIQII tO COSCO FIRE PROTECTION Page 5 2nd floor 4 head unit Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn DIOI 17.01 1.101 IT 6.328 1.000 12.051 K Factor = 4.90 to 120 0.0 6.328 16.674 EQOI 17.01 0.0763 0.0 7.328 0.559 Vel = 5.73 0.0 17.01 29.284 K Factor = 3.14 1 17.01 1.101 2E 7.65 8.600 29.284 K Factor @ node EQol to 150 IT 9.563 17.213 0.0 2 17.01 0.0504 0.0 25.813 1.301 Vel = 5.73 0.0 17.01 30.585 K Factor = 3.08 3 17.15 1.101 IT 9.563 6.500 29.763 K Factor @ node EQOI to 150 0.0 9.563 0.0 2 17.15 0.0512 0.0 16.063 0.822 Vel = 5.78 0.0 17.15 30.585 K Factor = 3.10 5 18.09 1.101 IT 9.563 5.600 33.128 K Factor @ node EQOI to 150 0.0 9.563 0.0 4 18.09 0.0565 0.0 15.163 0.857 Vel = 6.10 0.0 18.09 33.985 K Factor = 3.10 7 19.56 1.101 IT 9.563 2.080 38.719 K Factor @ node EQ01 to 150 0.0 9.563 0.0 6 19.56 0.0653 0.0 11.643 0.760 Vel = 6.59 0.0 19.56 39.479 K Factor = 3.11 2 34.16 1.101 IT 9.563 9.000 30.585 to 150 0.0 9.563 0.0 4 34.16 0.1832 0.0 18.563 3.400 Vel = 11.51 4 18.09 1.101 IT 9.563 4.100 33.985 to 150 0.0 9.563 0.0 6 52.25 0.4021 0.0 13.663 5.494 Vél = 17.61 6 19.56 1.394 2T 19.046 21.000 39.479 to 150 0.0 19.046 0.0 8 71.81 0.2295 0.0 40.046 9.190 Vel = 15.10 8 0.0 1.394 2E 9.523 19.000 48.669 to 150 0.0 9.523 0.0 23 71.81 0.2295 0.0 28.523 6.546 Vel = 15.10 23 0.0 1.598 3E 17.484 98.000 55.215 to 150 3T 34.968 52.452 0.0 TOR 71.81 0.1180 0.0 150.452 17.754 VeI= 11.49 Computer Programs by Hydratec Inc. Route 111 W i n d h a m N . H . U S A 0 3 0 8 7 I lila. %jai,ulaUJl to - %JLCII lual U COSCO FIRE PROTECTION Page 6 2nd flbor4 head unit Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. •'C11 or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn TOR 0.0 2.157 0.0 19.000 72.969 to 120 0.0 0.0 9.729 * Fixed loss = 1.5 BOR 71.81 0.0414 0.0 19.000 0.786 Vel = 6.30 BOR 0.0 4.1 2E 29.067 40.000 83.484 to 140 0.0 29.067 1.516 Dl 71.81 0.0014 0.0 69.067 0.094 Vel = 1.75 DI 0.0 4.07 IF 6.373 77.000 85.094 to 150 IE 15.932 22.305 0.217 B1 71.81 0.0012 0.0 99.305 0.123 Vel = 1.77 BI 0.0 4.1 IT 29.067 5.500 85.434 to 140 0.0 29.067 0.0 B2 71.81 0.0014 0.0 34.567 0.047 Vol = 1.75 B2 0.0 4.1 IE 14.534 5.000 85.481 to 140 lZfa 0.0 14.534 12.576 B3 71.81 0.0014 0.0 19.534 0.027 Vol = 1.75 B3 0.0 4.1 IE 14.534 5.500 98.084 to 140 0.0 14.534 0.0 B4 71.81 0.0013 0.0 20.034 0.027 Vol = 1.75 B4 0.0 5.86 1G 3.834 60.000 98.111 to 150 IT 38.342 42.177 0.866 S 71.81 0.0002 0.0 102.177 0.022 Vel = 0.85 S 100.00 5.89 2G 7.862 180.000 98.999 Qa = 100 to 150 IT 39.308 47.170 -7.073 J 171.81 0.0010 0.0 227.170 0.235 Vel = 2.02 J 0.0 8.27 0.0 70.000 92.161 to 140 0.0 0.0 TEST 171.81 0.0002 0.0 70.000 0.016 Vol = 1.03 0.0 171.81 92.177 K Factor = 17.90 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - Fire Protection by Computer Design COSCO FIRE PROTECTION 10695 TREENA STREET SUITE 105 CARLSBAD, CA 92131 858 444-2000 Job Name : 3RD floor 4 head unit Building : Building Two Location 2006 Costa Del Mar Rd Carlsbad System 3RD floor Contract : IOCB-0206 Data File : LCRV 3.wxl Computer Programs by Hydratec Inc. Route 111 Windham N.H. U S A 0 3 0 8 7 COSCO FIRE PROTECTION Page 1 3RD floor 4 head unit Date 113005 HYDRAULIC DESIGN INFORMATION SHEET Name - La Costa Resort and Spa • Date - Location - 2006 Costa Del Mar Rd Carlsbad Building - Building Two System No. - 3RD floor Contractor - Cosco Fire Protection Inc Contract No. - 10CB-0206 Calculated By - PG Drawing No. - FP4 Construction: (xx) Combustible Non-Combustible Ceiling Height 9' OCCUPANCY - Residential S Type of Calculation: ( x)NFPA 13 Residential (x)NFPA 13R ( )NFPA 13D Y Number of Sprinklers Flowing: ( )1 ( )2 (x)4 S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 17 Gpm System Type Listed Pres. at Start Point - 12 Psi (x) Wet ( ) Dry D MAXIMUM LISTED SPACING 18 x 18 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - 100 Gpm Make tyco Model LFII I Elevation at Highest Outlet - Feet Size K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 76.25 Psi Required 58.8 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 5-17-05 Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 113 Elev. R Residual (Psi) - 105 Other Well Flow (Gpm) - 1234 Proof Flow Gpm S Elevation - 56.33 P Location: ESTRELLA DEL MAR @ COSTA DEL MAR RD - P L Source of Information: COSCO FIRE PROTECTION / CWD FLOW TEST Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03 0 8 7 '-I COSCO FIRE PROTECTION Page 2 3RD floor 4 head unit Date 113005. City Water Supply: Cl - Static Pressure : 113 C2 - Residual Pressure: 105 C2 - Residual Flow :1234 Demand: Dl - Elevation : 8.458 D2 - System Flow : 76.249 stem Pressure : 67.699 F-lose D2 - Sr'Demand dj City). — ) : 100 TOT D3 D3 - System Demand : 176.249 Safety Margin : 45.083 15C 140 130 P 120 R 110 E 100 S90 On U 70 R601 E5° 40 30 20 10 I I I I ------ ---- -- ---- 1____________ I I I I 200 400 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 - ---.-..J COSCO FIRE PROTECTION Page 3 3RD floor 4 head unit Date 113005. Fitting Legend Abbrev. Name 1/2 % 1 11/4 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45 Elbow I I I 1 2 2 1 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90'FlowlhruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 SI 91 101 121 Zfa Febco 826YD Fitting generates a Fixed Loss Based on Flow ComDuter Proarams by Hydratec Inc. Route 111 Windham N.H. USA 03087 I iwoouivi I IJVV JUIIIIIIQI) COSCO FIRE PROTECTION Page 4 3RD floor 4 head unit Date 113005 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. DIOI 25.5 4.9 12.05 na 17.01 1 75.86 K = K @ EQ01 12.61 na 17.01 3 75.86 K= K© EQQ1 13.07 na 17.32 5 75.86 K=K©EQOI 16.37 na 19.38 7 75.86 K = K @ EQOI 22.14 na 22.54 2 75.86 13.91 na 4 75.86 17.34 na 6 75.86 23.12 na 8 75.86 34.16 na TOR 75.86 43.1 na BOR 46.0 58.88 na Dl 42.5 60.5 na BI 42.0 60.85 na 82 42.0 60.9 no B3 42.0 73.6 na B4 42.0 73.63 na S 40.0 74.52 na 100.0 J 56.33 67.68 na TEST 56.33 67.7 na 0.0525 324 12.0 The maximum velocity is 18.1 and it occurs in the pipe between node s 4 a n d 6 Computer Programs by Hydratec Inc. Route 111 Windham N.H . U S A 0 3 0 8 7 I Ij II %JcH%.,UIQLI%JI I - I IL.I IV V IIIIQI I I COSCO FIRE PROTECTION Page 5 3RD floor 4 head unit Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point . Qt Pf/UL Eqv. Ln. Total Pf Pn DIOI 17.01 1.101 IT 6.328 1.000 12.051 K Factor =4.90 to 120 0.0 6.328 0.0 EQOI 17.01 0.0761 0.0 7.328 0.558 Vel = 5.73 0.0 17.01 12.609 K Factor = 4.79 1 17.01 1.101 2E 7.65 8.600 12.609 K Factor © node EQOI to. 150 IT 9.563 17.213 0.0 2 17.01 0.0504 0.0 25.813 1.302 Vel = 5.73 0.0 17.01 13.911 K Factor = 4.56 3 17.32 1.101 IT 9.563 6.500 13.073 K Factor @ node EQ01 to 150 0.0 9.563 0.0 2 17.32 0O522 0.0 16.063 0.838 Vel = 5.84 0.0 17.32 13.911 K Factor = 4.64 5 19.38 1.101 IT 9.563 5.600 16.369 K Factor © node EQOI to 150 0.0 9.563 0.0 4 19.38 0.0642 0.0 15.163 0.974 Vel = 6.53 0.0 19.38, 17.343 K Factor = 4.65 7 22.54 1.101 IT 9.563 2.080 22.136 K Factor © node EQOI to . 150 0.0 9.563 0.0 6 22.54 0.0849 0.0 11.643 0.988 Vet = 760 0.0 22.54 23.124 K Factor = 4.69 2 34.33 1.101 IT 9.563 9.000 13.911 to 150 0.0 9.563 0.0 4 3433 0.1849 0.0 18.563 3.432 Vel = 11.57 4 19.38 1.101 IT 9.563 4.100 17.343 to 150 0.0 9563 0.0 6 53.71 0.4231 . 0.0 13.663 5.781 Vel = 18.10 6 22.54 1.394 2T 19.046 24.000 23.124 to .150 0.0 19.046 0.0 8 76.25 0.2564 0.0 43.046 11.038 Vel = 16.03 8 0.0 1.598 2E 11.656 44.500 34.162 to 150 IT 11.656 23.312 0.0 TOR 76.25 0.1318 0.0 67.812 8.941 Vel = 12.20 TOR 0.0 2.157 0.0 29.000 43.103 to 120 0.0 0.0 14.432 * Fixed loss = 1.5 BOR 76.25 0.0462 0.0 29.000 1.341 Vel = 6.69 Computer Programs by Hydratec Inc. Route 111 W i n d h a m N . H . U S A 0 3 0 8 7 I II 101 .,0I,UIQLIIJu 10 - %JLQ1 ivai U COSCO FIRE PROTECTION Page 6 3RD floor 4 head unit Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn BOR 0.0 4.1 2E 29.067 40.000 58.876 to 140 0.0 29.067 1.516 DI 76.25 0.0015 0.0 69.067 0.105 Vel = 1.85 Dl 0.0 4.07 IF 6.373 77.000 60.497 to 150 IE 15.932 22.305 0.217 BI 76.25 0.0014 0.0 99.305 0.137 Vel= 1.88 BI 0.0 4.1 IT 29.067 5.500 60.851 to 140 0.0 29.067 0.0 B2 76.25 0.0015 0.0 34.567 0.053 Vel = 1.85 B2 0.0 4.1 1 14.534 5.000 60.904 to 140 lZfa 0.0 14.534 12.661 B3 76.25 0.0015 . 0.0 19.534 0.030 Vel = 1.85 B3 0.0 4.1 IE 14.534 5.500 73.595 to 140 0.0 14.534 0.0 B4 76.25 0.0015 0.0 20.034 0.031 Vel = 1.85 B4 0.0 5.86 IG 3.834 60.000 73.626 to 150 IT 38.342 42.177 0.866 S 76.25 0.0002 0.0 102.177 0.024 Vel = 0.91 S 100.00 5.86 2G 8.148 180.000 74.516 Qa= 100 to 155 iT 40.74 48.888.. -7.073. J 176.25 0.0010 0.0 228.888 0.239 Vel= 2.10 J 0.0 8.27 0.0 70.000 67.682 to 140 0.0 0.0 0.0 TEST 176.25 0.0002 0.0 70.000 . 0.017 Vel = 1.05 0.0 176.25 67.699 K Factor = 21.42 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 030 8 7 --- Fire Protection by Computer Design COSCO FIRE PROTECTION 10695 TREENA STREET SUITE 105 CARLSBAD, CA 92131 858 444-2000 Job Name : 3RD floor 4 head CORRIDOR Building : Building Two 3rd FLOOR CORRIDOR Location : 2006 Costa Del Mar Rd Carlsbad System : 3RD floor CORR Contract : 1 OCB-0206 Data File : LCRV 3.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 COSCO FIRE PROTECTION• Page 1 3RD floor 4 head CORRIDOR Date 113005 HYDRAULIC DESIGN. INFORMATION SHEET Name - La Costa Resort and Spa Date - Location - 2006 Costa Del Mar Rd Carlsbad Building - Building Two 3rd FLOOR CORRIDOR System No. - 3RD floor CORR Contractor - Cosco Fire Protection Inc Contract No. - 10CB-0206 Calculated By - PG Drawing No. - FP4 Construction: (xx) Combustible ( ) Non-Combustible Ceiling Height 9' OCCUPANCY - Residential S Type of Calculation: ( x)NFPA 13 Residential (x)NFPA 13R ( )NFPA 13D Y Number of Sprinklers Flowing: ( )1 C )2 (x)4 S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 21 Gpm System Type Listed Pres. at Start Point - 25 Psi (x) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - 100 Gpm Make tyco Model LFII HSW I Elevation at Highest Outlet - Feet Size K-Factor 4.2 G Note: Temperature Rating 155 N Calculation Gpm Required 86.65 Psi Required 50.75 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 5-17-05 Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 113 Elev. R Residual (Psi) - 109 Other Well Flow (Gpm) - 1234 Proof Flow Gpm S Elevation - 56.33 P Location: ESTRELLA DEL MAR & COSTA DEL MAR RD P L Source of Information: COSCO FIRE PROTECTION / CWD FLOW TEST Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 VVdLI øUI4flY UIV IL) COSCO FIRE PROTECTION Page 2 3RD floor 4 head CORRIDOR Date 113005 City Water Supply: . Demand: Cl - Static Pressure : 113 Dl - Elevation : 8.458 C2 - Residual Pressure: 105 . D2 - System Flow : 86.654 stem Pressure : 59.948 C2 - Residual Flow : 1234 D2 - S rlDemand Hosedj City) ______ Hose ) : 100 D3 - System Demand : 186.654 Safety Margin : 52.809 150 140 130 In 120 . I-' : - ____ ______ -------------- ____ -.------.---.----- _________ C2 —e----_____________ ___________ _____________ ______________ E 100 S90 I 09w - ------- - U70 R6° E 50 40 30 20 10 l...........•........... ......... ........ ..... 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N'1.85) . . ComDuter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 - III I IA I 7 - COSCO FIRE PROTECTION. Page 3 3RD floor 4 head CORRIDOR Date 113005 Fitting Legend Abbrev. Name % % 1 11/4 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45' Elbow I 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 - 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I 90' Flow Thru Tee 3 4 5 6 8 10 - 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zfa Febco 826YD Fitting generates a Fixed Loss Based on Flow Comnuter Programs by Hvdratec Inc. Route 111 Windham N.H. USA 03087 I I quoQUIV I I fllVV ui III iiaiy - j I rutIJruL., COSCO FIRE PROTECTION Page 4 3RD floor 4 head CORRIDOR Date 113005 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. 0101 25.5 4.2 25.0 na 21.0 0.082 256 25.0 D102 25.5 4.2 25.0 na 21.0 0.082 256 25.0 D103 . 25.5 4.2 25.0 na 21.0 0.082 256 25.0 0105 25.5 4.2 25.0 na 21.0 0.082 256 25.0 12 75.86 K = K @ EQI2 28.2 na 21.0 13 75.86 K=K@EQ13 28.44 na 21.17. 8 75.86 . 29.73 na 14 75.86 K = K © E0I4 30.94 na 22.08 15 75.86 K = K @ EQI5 31.25 na 22.4 TOR 75.86 34.92 na BOR 46.0 50.79 na Dl 42.5 52.44 na BI 42.0 52.83 na B2 42.0 52.9 na B3 42.0 65.79 na B4 42.0 65.83 na S 40.0 66.73 na 100.0 J 56.33 59.93 na TEST 56.33 59.95 na The maximum velocity is 13.86 and it occurs in the pipe between no d e s 1 5 a n d T O R Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03 0 8 7 - I IlIQI jQIjUIQLIJI i - I IQ.I IV V 111101110 COSCO FIRE PROTECTION - Page 5 '3RD floor 4 head CORRIDOR Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. licit.or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn DIOI 21.00 1.101 4E 10.126 12.000 25.000 K Factor =4.20 to 120 IT 6.328 16.454 0.0 EQ12 21.0 0.1125 0.0 28.454 3.202 Vet = 7.08 0.0 21.00 28.202 K Factor = 3.95 0102 21.00 1.101 4E 10.126 10.000 25.000 K Factor =4.20 to 120 IT 6.328 16.454 0.0 EQ13 21.0 01125 0.0 26.454 2.977 Vet = 7.08 0.0 21.00 27.977 K Factor = 3.97 D103 21.00 1.101 4E 10.126 10.000 25.000 K Factor =4.20 to 120 IT 6.328 16.454 0.0 FQ14 21.0 0.1125 0.0 26.454 2.977 Vel = 7.08 0.0 21.00 27.977 K Factor = 3.97 D105 21.00 1.101 4E 10.126 5.500 25.000 K Factor =4.20 to 120 IT 6.328 16.454 0.0 EQ15 21.0 0.1125 0.0 21.954 2.470 Vel= 7.08 0.0 21.00 27.470 K Factor = 4.01 12 21.00 1.394 0.0 10.000 28.202 K Factor @ node EQ12 to 150 0.0 0.0 0.0 13 21.0 0.0236 0.0 10.000 0.236 Vel = 4.41 13 21.17 1.394 IT 9.523 5.600 28.438 K Factor © node EQ 13 to 150 V 0.0 9.523 0.0 8 42.17 0.0857 0.0 15.123 1.296 Vel = 8.86 8 0.0 1.598 IT 11.656 15.700 29.734 to 150 0.0 11.656 0.0 14 42.17 0.0441 0.0 27.356 1.206 Vel = 6.75 14 22.09 1.598 0.0 3.200 30.940 K Factor @ node EQI4 to 150 0.0 0.0 0.0 15 64.26 0.0962 0.0 3.200 0.308 V Vel = 10.28 15 22.39 1.598 2E 11.656 10.330 31.248 K Factor @ node EQI5 to 150 0.0 11.656 0.0 TOR 86.65 0.1670 0.0 21.986 3.672 Vet = 13.86 TOR 0.0 2.157 0.0 24.500 34.920 to 120 0.0 0.0 14.432 * Fixed loss = 1.5 BOR 86.65 0.0586 0.0 24.500 - 1.436 Vel = 7.61 BOR 0.0 4.1 2E 29.067 40.000 50.788 to 140 0.0 29.067 1.516 Dl 86.65 0.0019 0.0 69.067 0.133 Vol = 2.11 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1 - I luau jQlIjUI0UUI 10 - .JIQI IUOI U S COSCO FIRE PROTECTION Page 6 3RD floor 4 head CORRIDOR Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Fin DI 0.0 4.07 IF 6.373 77.000 52.437 to 150 1 15.932 22.305 0.217 BI 86.65 0.0018 0.0 99.305 0.174 VeI= 2.14 BI 0.0 4.1 IT 29.067 5.500 52.828 to 140 0.0 29.067 0.0 B2 86.65 0.0019 0.0 34.567 0.067 Vel = 2.11 B2 0.0 4.1 IE 14.534 5.000 52.895 to 140 IZfa 0.0 14.534 12.861 B3 86.65 0.0019 0.0 19.534 0.038 Vel = 2.11 B3 0.0 4.1 IE 14.534 5.500 65.794 to 140 0.0 14.534 0.0 B4 86.65 0.0019 0.0 20.034 0.038 Vel = 2.11 84 0.0 5.86 IG 3.834 60.000 65.832 to 150 IT 38.342 42.177 0.866 S 86.65 0.0003 0.0 102.177 0.031 Vel = 1.03 S 100.00 5.89 2G 7.862 180.000 66.729 Qa = 100 to 150 IT 39.308 47.170 -7.073 J 186.65 0.0012 0.0 227.170 0.274 Vel = 2.20 J 0.0 8.27 0.0 70.000 59.930 to 140 0.0 0.0 0.0 TEST 186.65 0.0003 0.0 70.000 0.018 Vel = 1.11 0.0 186.65 59.948 K Factor = 24.11 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 hydraulic calculations Page 1 3RD floor 4 head CORRIDOR Date 113005 HYDRAULIC DESIGN INFORMATION SHEET Name - La Costa Resort and Spa Date - Location - 2006 Costa Del Mar Rd Carlsbad Building - Building Two 3rd FLOOR CORRIDOR System No. - 3RD floor CORR Contractor - Cosco Fire Protection Inc Contract No. - 10CB-0206 Calculated By - PG Drawing No. - FP4 Construction: (xx) Combustible C ) Non-Combustible Ceiling Height 9' OCCUPANCY - Residential Type of Calculation: ( x)NFPA 13 Residential (x)NFPA 13R ( )NFPA 13D Number of Sprinklers Flowing: C )l C )2 (x)4 )Other )Specific Ruling Made by Date Gpm System Type Psi (x) Wet ( ) Dry Deluge ( ) PreAction Gpm Sprinkler or Nozzle Gpm Make tyco Model LFII HSW Feet Size K-Factor 4.2 Temperature Rating 155 Calculation Gpm Required 86.65 Psi Required 50.75 At Test Summary C-Factor Used: Overhead 150 Underground 150 S Y S T E M D E S I G N Listed Flow at Start Point - 21 Listed Pres. at Start Point - 25 MAXIMUM LISTED SPACING 16 x 16 Domestic Flow Added - 0 Additional Flow Added - 100 Elevation at Highest Outlet - Note: Water Flow Test: Date of Test - 10-11-04 Time of Test - Static (Psi) - 126 Residual (Psi) - 109 Flow (Gpm) - 3000 Elevation - 40 Location: ESTRELLA DEL MAR W A T E R S P P L Y Pump Data: Rated Cap. 8 Psi Elev. Other Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm Source of Information: MDS CONSULTING VVdLI ouppiy -Ul VU I#) hydraulic calculations Page 2 3RD floor 4 head CORRIDOR Date 113005 City Water Supply: Demand: Cl - Static Pressure : 126 Dl - Elevation : 15.531 C2 - Residual Pressure: 109 02 - System Flow : 86.654 tem Pressure : 66.729 C2 - Residual Flow : 3000 02- SrA5dj Hose City) ______ Hose Demand) : 100 D3 - System Demand : 186.654 Safety Margin : 59.171 150 140 130 p120 -- R 110 ____ _____ ______ - _________ --------------- E10° S90 S80 u70 ;02 R60D E5° 40 30 20 -- DJL 10 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (NA 1.85) C2 Corn outer Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 rILL1119b UbU OUIIIIIIdI hydraulic calculations Page 3 3RD floor 4 head CORRIDOR - Date 113005 Fitting Legend Abbrev. Name % % 1 1% 1% 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45' Elbow I I 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90' Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zfa Febco 826YD Fitting generates a Fixed Loss Based on Flow Corn outer Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD hydraulic calculations Page 4 3RD floor 4 head CORRIDOR Date 113005 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 0101 25.5 4.2 25.0 na 0102 25.5 4.2 25.0 na D103 25.5 4.2 25.0 na D105 25.5 4.2 25.0 na 12 75.86 K=K@EQI2 28.2 na 13 75.86 K=K@EQI3 28.44 na 8 75.86 29.73 na 14 75.86 K=K@EQI4 30.94 na 15 75.86 K=K@EQ1S 31.25 na TOR 75.86 34.92 na BOR 46.0 50.79 na Dl 42.5 52.44 na BI 42.0 52.83 na B2 42.0 52.9 na 83 42.0 65.79 na B4 42.0 65.83 na S 40.0 66.73 na 21.0 0.082 256 25.0 21.0 0.082 256 25.0 21.0 0.082 256 25.0 21.0 0.082 256 25.0 21.0 21.17 22.08 22.4 100.0 The maximum velocity is 13.86 and it occurs in the pipe between nodes 15 and TOR Final Calculations - Hazen-Williams hydraulic calculations Page 5 3RD floor 4 head CORRIDOR Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt PfIUL Eqv. Ln. Total Pf Pn 0101 21.00 1.101 4E 10.126 12.000 25.000 K Factor 4.20 to 120 IT 6.328 16.454 0.0 EQ12 21.0 01125 0.0 28.454 3.202 Vel = 7.08 0.0 21.00 28.202 K Factor = 3.95 0102 21.00 1.101 4E 10.126 16.000 25.000 K Factor = 4.20 to 120 IT 6.328 16.454 0.0 EQ13 21.0 0.1125 0.0 26.454 2.977 Vel = 7.08 0.0 21.00 27.977 K Factor= 3.97 D103 21.00 1.101 4E 10.126 10.000 25.000 K Factor = 4.20 to 120 IT 6.328 16.454 0.0 EQ14 21.0 0.1125 0.0 26.454 2.977 Vel = 7.08 0.0 21.00 27.977 K Factor = 3.97 0105 21.00 1.101 4E 10.126 5.500 25.000 K Factor = 4.20 to 120 IT 6.328 16.454 0.0 EQ15 21.0 0.1125 0.0 21.954 2.470 Vel = 7.08 0.0 21.00 27.470 K Factor = 4.01 12 21.00 1.394 0.0 10.000 28.202 K Factor @ node EQ 12 to 150 0.0 0.0 0.0 13 21.0 0.0236 0.0 10.000 0.236 Vel = 4.41 13 21.17 1.394 IT 9.523 5.600 28.438 K Factor © node EQI3 to 150 0.0 9.523 0.0 8 42.17 0.0857 0.0 15.123 1.296 Vel = 8.86 8 0.0 1.598 IT 11.656 15.700 29.734 to 150 0.0 11.656 0.0 14 42.17 0.0441 0.0 27.356 1.206 Vel = 6.75 14 22.09 1.598 0.0 3.200 30.940 K Factor @ node EQi4 to 150 0.0 0.0 0.0 15 64.26 0.0962 0.0 3.200 0.308 Vel = 10.28 15 22.39 1.598 2E 11.656 10.330 31.248 K Factor @ node EQ 15 to 150 0.0 11.656 0.0 TOR 86.65 0.1670 0.0 21.986 3.672 Vel = 13.86 TOR 0.0 2.157 0.0 24.500 34.920 to 120 0.0 0.0 14.432 * Fixed loss = 1.5 BOR 86.65 0.0586 0.0 24.500 1.436 Vel = 7.61 BOR, 0.0 4.1 2E 29.067 40.000 50.788 to 140 0.0 29.067 1.516 Dl 86.65 0.0019 0.0 69.067 0.133 Vel = 2.11 'FinI Calculations - Standard hydraulic calculations Page 6 3RD floor 4 head CORRIDOR Date 113005 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn DI 0.0 4.07 IF 6.373 77.000 52.437 to 150 1E 15.932 22.305 0.217 BI 86.65 0.0018 0.0 99.305 0.174 Vel = 2.14 81 0.0 4.1 IT 29.067 5.500 52.828 to 140 0.0 29.067 0.0 B2 86.65 0.0019 0.0 34.567 0.067 Vel = 2.11 B2 0.0 4.1 IE 14.534 5.000 52.895 to 140 IZfa 0.0 14.534 12.861 B3 86.65 0.0019 0.0 19.534 0.038 Vet = 2.11 B3 0.0 4.1 1 14.534 5.500 65.794 to 140 0.0 14.534 0.0 B4 86.65 0.0019 0.0 20.034 0.038 Vet = 2.11 B4 0.0 5.86 IG 3.834 60.000 65.832 to 150 IT 38.342 42.177 0.866 S 86.65 0.0003 0.0 102.177 0.031 Vel = 1.03 100.00 Qa= 100.00 186.65 66.729 K Factor= 22.85 San Diego Branch Office 10695 Treena Street., Suite #105 San Diego, CA 92131 (858) 444-2000 fax: 444-2056 State License No: C-16-577621 www.coscofire.com MATERIAL SUBMITTAL Date: 12/28/05 TO: CARLSBAD FIRE DEPT 1635 FARADAY AVE. CARLSBAD, CA.92008 LA COSTA BLDG 2 2006. COSTA DEL MAR RD. CARLSBAD, CA.92009 CB-050422 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: OFELIA RELLEGUE NFPA UR Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle San Diego Branch Office 10695 Treena Street., Suite #105 ,,lI San Diego, CA 92131 (858) 444-2000 fax: 444-2056 FIRE PROTECTION License No: C-16-577621 I www.coscofire.com TABLE OF CONTENTS Fire Sprinkler System Components Tyco LFIL Residential Pendent Sprinkler Tyco LFII Residential Sidewall Sprinkler Tyco TY-FRB Pendent Sprinkler Tyco TY-FRB Sidewall Sprinkler Tyco Grooved Butterfly Valve Wilkens Model 375 ADA RPDA Potter VSR-F Flow Switch Potter Electric Bell Pipe and Fittings Allied Schedule 10 & 40 pipe Tyco Grooved Coupling Tyco Blazemaster CPVC Pipe and Fittings Pipe Hangers/Miscellaneous Materials Tolco Fig. 28 Standoff Hanger Tolco Fig. 22 CPVC Hanger Tolco Fig. 23 Hanger Double Fastener Strap Type Tolco Fig. 24 Double Fastener Side Mount Tolco Fig. 4 Pipe Clamp tqCU /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series LFII Residential Concealed Pendent Sprinklers, Flat Plate 49 K-factor General Description The Series LFII (TY3596) Residential Concealed Pendent Sprinklers are decorative, fast response, fusible sol- der sprinklers designed for use in resi- dential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut to help assure a perfect fit installation. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 131); wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY3596) has a 4.9 (60,5) K-factor that provides the re- quired residential flow rates at reduced IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. pressures, enabling smaller pipe sizes and water supply requirements. The Series LFII (TY3596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII (TY3596) Residential Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. WARNINGS The Series LFII (TY3596) Residential Concealed Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY3596 Technical Data Approvals: UL and C-UL Listed. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.9 GPM/p5i112 (70,6 LPM/barl'2) Temperature Rating: 160°F/71 °C Sprinkler with 135017/570C Cover Plate Vertical Adjustment: 1/2 inch (12,7 mm) Finishes: Cover Plate: Flat White, Bright White, Chrome, or Custom Physical Characteristics: Body ..............Brass Cap ..............Bronze Saddle .............Brass Sealing Assembly .......... Beryllium Nickel w/ Teflont Soldered Link Halves .....Nickel Lever .............Bronze Compression Screw ......Brass Deflector ......Copper or Brass Guide Pin Housing .....Bronze Page 1 of 4 JULY, 2005 TFP442 Page 2 of 4 TFP442 Minimum Flow (b) and Minimum Flow (b) and Minimum Flow (b) and Maximum Maximum Residual Pressure Residual Pressure Residual Pressure Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Area (a) Ft. (Max. 2 Inch Rise (Greater Than 2 inch (Greater Than 4 inch Ft. x Ft. (m) for 12 Inch Run) Rise Up To Rise Up To (mx m) Max. 4 Inch Rise Max. 8 Inch Rise for 12 Inch Run) for 12 Inch Run) 160°FIT1"C 1600FF71°C 160°FTh"C Sprinkler Sprinkler Sprinkler 12 x 12 12 13 GPM (49.2 LPM) N/A N/A (3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 14x14 14 13 GPM (53,OLPM) N/A N/A (4,3 x 4,3) (4,3) 7.0 psi (0,48 bar) 16 x 16 16 13 GPM (60,6 LPM) N/A N/A (4,9x4,9) (4,9) 7.0 psi (0,48 bar) 18x18 18 17 GPM (64,3 LPM) N/A N/A (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) I 20 x 20 20 20 GPM (75,7 LPM) N/A N/A (6,1x6,1) (6,1) 16.7 psi (1,l5bar) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 130 AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY3596) RESIDENTIAL CONCEALED PENDENT SPRINKLER Guide Pins .......Stainless Steel Support Cup ..........Steel Cover Plate ..........Copper Retainer ............Brass Cover Plate Ejection Spring ..... thinIcc Qtgaal tDuPont Registered Trademark Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. At this point the Deflec- tor supported by the Arms drops down to its operated position. The fusible link of the Sprinkler Assembly is com- prised of two link halves that are sol- dered together with a thin layer of sol- der. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The Series LFII (TV3596) Residential Concealed Pendent Sprinklers are UL and C-UL Listed for installation in ac- cordance with the following criteria. When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the Authority Having Jurisdic- tion. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. A minimum discharge of 0.1gpmlsq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing. The minimum spacing between sprinklers is 9 feet (2,7 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Ta- ble A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The Series LFll (TY3596) must be in- stalled in accordance with the follow- ing instructions: NOTES Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible link Assembly). A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- I TFP442 BODY (1&NPT) CAP SADDLE SUPPORT CUP WITH - ROLL FORMED THREADS GUIDE PIN GUIDE PIN HOUSING DEFLECTOR - THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SOLDER TAB SEALING ASSEMBLY SPRINKLER WRENCHING AREA COMPRESSION SCREW LEVER SOLDER LINK ELEMENT DEFLECTOR - l (OPERATED POSITION) SPRINKLERISUPPORT CUP ASSEMBLY RETAINER F ITh ThREAD DIMPLES 0 EJEcT1ON N SPRING COVER PLATEIRETAINER ASSEMBLY COVER PLATE FIGURE 1 SERIES LFII(TY3596) RESIDENTIAL CONCEALED PENDENT SPRINKLER Page 3 of 4 mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Cover Plate/Retainer Assembly by under- or over-tightening the Sprinkler. Read- just the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, and using the W-Type 18 Wrench shown in Fig- ure 2, install and tighten the Sprink- ler/Support Cup Assembly into the fit- ting. The W-Type 18 Wrench will accept a 1/2 inch ratchet drive. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH 2-1/2" DIA. 1/2' 991 THREADED SPRINKLER (635 mm 12,7 mm) FACE OF yJ NPT STMENT FITTING 1-7/8"±1/8" - (47.6 mm /8" GAP *3,2 mm) 3,2mm) COVER- SPRINKLER- MOUNTING RETAINER SUPPORT CUP J SURFACE ASSEMBLY ASSEMBLY (4,8 mm) - 33/16"DIA. (81,0 MM) i-ip SPRINKLER- SUPPORT CUP ASSEMBLY OPERATED SPRINKLER. COVER PLATE RETAINER 7/8" (22,2 mm) 1-1/8"(28,6 mm) DISPOSABLE PROTECTIVE CAP DEFLECTOR IN OPERATED POSITION FIGURE 3 SERIES LFII (TY3596) RESIDENTIAL CONCEALED PENDENT SPRINKLER INSTALLATION DIMENSIONS / PROTECTIVE CAP/ACTIVATED DEFLECTOR Page 4 of 4 TFP442 Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceil- ing installation and/or during applica- tion of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently push- ing the ceiling material against the center point of the Cap. NOTE As long as the protective Cap remains in place, the system is considered to be "Out Of Service". Step 5. After the ceiling has been com- pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate As- sembly until its flange comes in con- tact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceil- ing panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be en- gaged sufficiently to contact the ceil- ing, the Sprinkler Fitting must be repo- sitioned. Care and Maintenance The Series LFII (TY3596) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of a Cover Plate may delay the sprinkler operation in a fire situ- ation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad-vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire & Building Products. No warranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire & Building Products or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applica- ble Standards of the National Fire Pro- tection Association, and/or the stand- ards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire & Building Products to be defec- tive shall be either repaired or re- placed, at Tyco Fire & Building Prod- ucts' sole option. Tyco Fire & Building Products neither assumes, nor author- izes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire & Building Products shall not be responsible for sprinkler system de- sign errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE & BUILDING PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LI- ABILITY OR UNDER ANY OTHER LE- GAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE & BUILDING PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE & BUILDING PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARR.4N- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR- POSE Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability.. Sprinkler Assembly: Series LFII (TY3596), K=4.9, Residen- tial Concealed Pendent Sprinkler with- out Cover Plate Assembly, P/N 51-112-1-160. Cover Plate Assembly: Cover Plate Assembly having a (spec- ify) finish for the Series LFII (TY3596), K=4.9, Residential Concealed Pen- dent Sprinkler, P/N (specify). Chrome ..................PIN 56-122-9-135 Off White .................PIN 56-122-0.135 Bright White ............... P/N 56-122-4-135 Flat White ................P/N 56-122-5-135 White (RAL9O1O) ........... P/N 56-122.3-135 Custom ..................PIN 56-122-X-135 "Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 18 Sprinkler Wrench, PIN 56-000-1-265. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCU Fire & Building liPro du c ts Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series LFII Residential Pendent Sprinklers 49 K-factor General Description The Series LFII (TY2234) Residential Pendent Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. When aesthet- ics and optimized flow characteristics are the major consideration, the Series LFII (TY2234) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 131); wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY2234) has a 4.9 (70,6) K-factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (1Y2234) is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Es- cutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. adjustment or up to 1/2 Inch (12,7 mm) of total adjustment from the flush ceil- ing position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY2234) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. WARNINGS The Series LFII (7Y2234) Residential Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The Installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY2234 Page 1 of 8 MARCH, 2005 TFP400 Page 2 of 8 TFP400 Minimum Flow (b) and Minimum Flow (b) and Minimum Flow ('a) and Maximum Maximum Residual Pressure Residual Pressure Residual Pressure Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Area (a) R. (Max. 2 inch Rise (Greater Than 2 inch Rise (Greater Than 4 inch Rise Ft. x Ft. (m) for 12 inch Run) Up To Max. 4 inch Rise for 12 inch Run) Up To Max. 8 inch Rise for 12 Inch Run) (m x m) 155°F168°C or 1550F/68"C 175°F179°C 155°F168"C 175°F!79"C 175°F/79"C 12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) (3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 14 x 14 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) (4,3 x 4,3) (4,3) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 16 x 16 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64.3 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) (4,9 x 4,9) (4,9) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0.48 bar) 12.0 psi (0,83 bar) 18x 18 18 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 20 x 20 20 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 21 GPM (79,5 LPM) 22 GPM (83,3 LPM) (6,1 x 6,1) (6,1) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 18.4 psi (1,27 bar) 20.2 psi (1,39 bar) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures ar e c a l c u l a t e d using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS Technical Data Approvals: UL and C-UL Listed. NYC Approved under MEA 44-03-E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: 1< = 4.9 GPM/psi'/2 (70,6 LPM/bari/2) Temperature Rating: 155°F1680C or 175017/790C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame ..............Brass Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Tefiont Bulb .........3 mm dia. Glass Compression Screw .....Bronze Deflector ...........Bronze Ejection Spring - . . . Stainless Steel tDuPont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFll (TY2234) Residential Pendent Sprinklers are UL and C-UL Listed for installation in accordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority havingJuris- diction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as speci- fied in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. A minimum discharge of 0.1 gpmlsq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. For "Horizontal Ceilings" (maximum 2 inch rise for 12 inch run), the sprin- klers are to be installed with a deflec- tor to ceiling distance of 1-3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2. NOTES The "Beam Ceiling Design Criteria" section starting on Page 4 permits de- flector to ceiling distances up to 15-3/4 inches. So as to help avoid obstructions to water distnbution, a maximum 12 inch deflector-to-ceiling distance is permit-ted forNFPA 130 andNFPA 13Rappli- cations where the sprinklers are located in closets. For "Sloped Ceilings" (greater than 2 inch rise up to 8 inch rise for 12 inch run), the sprinklers are to be installed with a deflector to ceiling TFP400 Page 3 of 8 7/16" (11,1 mm) 1/2" ESCUTCHEON ________ 2-7/8'DIA. 1 - Frame MAKE-IN SURFACE 2 - Button (73,0 mm) Bulb Compression 2 2-1/4" Screw Components: NOMINAL NPT PLATE SEATING H I 3 Sealing Assembly 1 6 - Deflector* ________ (57,2 mm) L _____ RENCI 1-5/8' I STYLE 20 (41,3 mm) I w RECESSED ESCUTCHEON * Temperature 5 .___.-..--I FLATS rating is indicated on 6* .__C=IJ_JIlZ= Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 SERIES LFII (TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS - 2-7/8" DIA. 7/16±1/8" (73,0 mm) I 1/2"(12,7 mm) r (11,1*3,2 mm) 2-1/4' DIA. I 1/4"(6.4 mm) I FACE OF I SPRINKLER (57,2 mm) [' MOUNTING FITTING PLATE I II' I _ T-7- MOUNTING 1/8" SURFACE/ (3,2 mm) CLOSURE / TY2234 1-8" (,9 mm) - 1-1/8"(28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY2234) RESIDENTIAL PENDENT SPRINKLER distance of 1-3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2 Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). WRENCH RECESS (END "A' USED FOR 1Y2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 4 of 8 TFP400 Beam Ceiling Design Criteria The Series LFII (TY2234) Residential Pendent Sprinklers are UL and C-UL Listed for installation in residential oc- cupancies with horizontal ceilings (i.e., slopes up to a 2 inch rise over a 12 inch run) with beams when installed in ac- cordance with the following criteria: General Information. The basic con- cept of this protection scheme is to locate the sprinklers on the underside of the beams, Ref. Figure 5, (not in the beam pockets); to identify the main beams that principally run in one direc- tion as "primary beams"; and, to iden- tify the beams that run principally per- pendicular to the main beams, as may be present (or in some cases may be necessary for proper sprinkler protec- tion), as "secondary beams". Primary and Secondary Beam Types. Solid surface, solid or hollow core, combustible or non-combustible. Primary and Secondary Beam Posi- tioning. Directly attached to the un- derside of a combustible or non-com- bustible smooth ceiling at any elevation. Primary Beam Cross-Section: Maxi- mum depth of 14 inches and the maxi- mum width is unlimited. The cross-sec- tional shape of the primary beam may be rectangular to circular. Secondary Beam Cross-Section. Maximum depth to be no greater than the primary beam and the maximum width is unlimited. The cross-sectional shape of the secondary beam may be rectangular to circular. Primary Beam Spacing. The primary beams (Fig. 6A) are to be 3 ft. -4 in. to 6 ft. from the compartment wall to cen- ter of the nearest beam and from cen- ter to center between beams. Secondary Beam Spacing. The sec- ondary beams principally run perpen- dicular to the primary beams. Secondary beams of a depth equal to the primary beam must be placed so that the beam pockets created by the primary beams do not exceed 20 feet in length (Fig. 6B). NOTE When the beam pockets created by the primal',' beams exceed 20 feet in length, the installation will require the use of secondary beams as described above. Otherwise, secondary beams need not be present. Secondary beams of a cross-sectional depth greater than one-quarter the depth of the primary beams are to be a minimum of 3 ft. - 4 in. from the compartment wall to center of the nearest beam and from center to cen- ter between beams (Fig. 6C). Secondary beams of a cross-sectional depth no greater than one-quarter the depth of the primary beams may be placed at any compartment wall to center of the nearest beam distance and from any center to center distance between beams (Fig. 6C). Lintels. Lintels over doorways exiting the compartment must be present. The minimum height for the lintels is 8 inches or no less than the depth of the Primary Beams, whichever is greater. Sprinkler Types. Series LFll (TY2234), 155F and 175F, Pendent and Recessed Pendent Residential Sprinklers. Sprinkler Coverage Area and Hy- draulic Design. The sprinkler cover- age areas and hydraulic design criteria as presented in the Table A for "Hori- zontal Ceilings" are to be applied. Sprinkler Position. The deflector to bottom of primary beams for the Series LFli (TY2234) Pendent Sprinklers or Series LFll (TY2234) Recessed Pen- dent Sprinklers is to be 1-1/4 to 1-314 inches (Fig. 5A). The vertical center- line of the Series LFll (TY2234) Pen- dent Sprinklers is to be no greater than half the primary beam cross-sectional width plus 2 inches from the centerline of the primary beam (Fig 513). NOTES Core drilllng of beams to allow the in- stallation of sprinkler drops requires consulting with a structural engineer. Where core drilling is not permitted, the previously stated sprinkler position criteria for the Series LFll (TY2234) Pendent Sprinklers allows for the sprinkler drop to be placed adjacent to the primaiy beam. Beam and Soffit Arrangements. A soffit is permitted to be placed around the perimeter of a compartment with the beam arrangement within the sof- fited area (Fig.7). The cross-section of the soffit may be any size as long as it does not create an obstruction to water distribution per the obstruction rules of NFPA 13 for residential sprinklers. When soffits are present, the pre- viously provided 3 ft. - 4 in. to 6 ft. "compartment wall to adjacent beam" distance for the primary and secon- dary beams is to be measured from the face of the soffit as opposed to the compartment wall. A__ 1Y2234 B : LE Ln MAXIMUM I ivni ONE-HALF BEAM WIDTH PLUS 2 (50,8 mm) FIGURE 5 SPRINKLER POSITIONING UNDER PRIMARY BEAMS (Refer to the "Beam Ceiling Design Criteria" section) NOTE Although the distance to the beams is measured from the face of the soffit, the sprinkler coverage area is to be measured from the compartment wall. I TFP400 Page 5 of 8 ALL FIGURES: I--A_-i. A_ -'. A-.—.j DISTANCES ARE I F IF F MEASURED TO 14 (356 mm) COMPARTMENT MAXIMUM WALL FACES .AND •Y TO CENTERLINES •. OFBEAMS A3to6'.O(1,OtO1,8m) FOR PRIMARY BEAMS HAy- MAXIMUM DEPTH PRIMARY MAXIMUM COWARTMENT WALLS FIGURE 6A PRIMARY BEAM SPANS UP TO 20'-O (6,1 m) h—A_.[. A_ -- A— k IF A=3'-4to6-0(1,0to1,8m) FOR PRIMARY BEAMS HAV- SECONDARY . B INGA 14'(356 mm) MAXIMUM BEAM DEPTH B =20'-0 (6,1 m) MAXIMUM FOR SECONDARY BEAMS THAT ARE TO BE EQUAL IN PRIMARY DEPTH TO PRIMARY BEAMS BEAM • AND THAT MUST BE IN PLACE . SO THAT PRIMARY BEAM POCKETS DO NOT EXCEED 20-0 (6,1 m) COMPARTMENT :. WALLS FIGURE 6B PRIMARY BEAM SPANS GREATER THAN 20-0' (6,1 m) h-A__-. A_ A —.-I I F ,I. . . C A3-4 t06-0 (1,0to1,8m) . \ FOR PRIMARY BEAMS HAy- 'I INGA14'(356 mm) MAXIMUM SECONDARY :. C DEPTH BEAM •.•.. ' C = Y-4"(1,0 m) MINIMUM FOR \ SECONDARY BEAMS HAVING DEPTHS GREATER THAN 25% OF PRIMARY BEAMS PRIMARY* —or— BEAM '•. C =ANY DISTANCE FOR SEC- ONDARY BEAMS HAVING DEPTHS UP TO 25% OF * REFER TO :.. . PRIMARY BEAMS FIGURE 6B COMPARTMENT FOR SPANS WALLS EXCEEDING 2(Y-O"(6,1 m) FIGURE 6C COMBINATIONS OF PRIMARY AND SECONDARY BEAMS FIGURE 6 BEAM ARRANGEMENTS (Refer to the "Beam Ceiling Design Criteria" section) Page 6 of 8 TFP400 Installation The Series LFII (TY2234) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6mm). A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Pendent sprinklers are to be installed in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series LFII Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. Recessed pendent sprinklers are to be installed in the pendent posi- tion with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series LFII (TY2234) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- TFP400 Page 7 of 8 age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad-vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac-côrdance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability.. Sprinkler Assembly: Series LFII (TY2234), K=4.9, Residen- tial Pendent Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155'F/68°C or Chrome Plated .........P/N 51-201-9-155 155°F/68°C White Polyester.........PIN 51.201-4-155 155°F/68°C White (RAL9O1O) ............. P/N 51-201-3-155 155°F168'C Natural Brass...........P/N 51-201-1-155 1751F/791C or Chrome Plated .........P/N 51-201-9-175 175'F179°C White Polyester.........P/N 51-201-4-175 175°F/79°C White (RAL9OIO) ............. P/N 51-201-3-175 175°F/79'C Natural Brass...........P/N 51-201-1-175 Eastern Hemisphere sales only. Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify) finish, P/N (specify). 1/2' (15 mm) Style 20 Chrome Plated .........P/N 56-705-9-010 1/2' (15 mm) Style 20 White Color Coated .................P/N 56-7054-010 1/2' (15 mm) Style 20 White (RALSO1O) ............. P/N 56-705-3-010 1/2' (15 mm) Style 20 Bright Brass Coated ................ PIN 56-705-2-010 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Page 8 of 8 TFP400 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, P e n n s y l v a n i a 1 9 4 4 6 tqCC Fire & Building liProducts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series LFII Residential Horizontal Sidewall Sprinklers 4,2 K-factor General Description The Series LFII (1Y1334) Residential Horizontal Sidewall Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII (TY1334) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 131); wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy pet NFPA 13. The Series LFII (TY1334) has a 4.2 (60,5) K-factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (1Y1334) is intended for use in areas with finished walls. It employs a two-piece Style 20 Recessed Escutch- eon. The Recessed Escutcheon pro- vides 1/4 inch (6,4 mm) of recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNINGS that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. adjustment or up to 1/2 inch (12,7 mm) of total. adjustment from the flush mounting surface position. The adjust- ment provided by the Recessed Es- cutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY1334) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. WARNINGS The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY1334 Page 1 of 8 APRIL, 2004 TFP4IO WRENCH RECESS ell (END 'A" USED FOR TY1334) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 2 of 8 TFP4IO 2 - Button Assembly FLATS Components: 5 3 2 1 3 - sealing Assembly 1 - Frame 7/16" mm) WRENCH Bulb Compression Screw Deflector * TOP-OF- 2-7/8" DIA. (73,0 mm) NOMINAL DEFLECTOR "1 MAKE-IN * Temperature rating is indicated on top CENTERLINE OF WATERWAY 7116" of Deflector. 1/2" NPT RECESSEDIJ (11,1 mm) STYLE 20 ESCUTCHEON END-OF- (41,3 mm) ESCUTCHEON DEFLECTOR 2-1/4" PLATE SEATING RECESSED (57,2 mm) SURFACE BOSS FIGURE 1 SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS 7/16±1/8" (11.1±3,2 mm) MOUNTING FACE OF SURFACE -.... - SPRINKLER FITTING TOP-OF- CLOSURE DEFLECTOR TY1334 2-7/8"DIA. (73,0 mm) 1/4"DIA. I 7/16" - (57,2 mm) I (11,1mm) MOUNTING PLATE 1/8" END-OF- DEFLECTOR - -_ BOSS (3,2 mm) 1-3/8" (34,9 mm) 1/2" (12,7 mm) 1-118'(28,6 mm) 1/4" (6,4 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER TFP4IO Page 3 of 8 Technical Data Approvals: UL and C-UL Listed. NYC Approved under MEA 44-03-E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.2 GPM/psi'/2 (60,5 LPM/barl/2) Temperature Rating: 155017/680C or 1750F/790C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame ..............Brass Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb .........3 mm dia. Glass Compression Screw .....Bronze Deflector ...........Copper tDupont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers are UL and C-UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority Having Ju- risdiction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A, B, C, and D as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A, B, C, and 0 for NFPA 130 and 13R as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpmlsq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed with an end-of- deflector-boss to wall distance of 1- 3/8 to 6 inches or in the recessed po- sition using only the Style 20 Re- cessed Escutcheon as shown in Figure 2. In addition the top-of-deflector-to-ceil- ing distance is to be within the range (Ref. Table A, B, C, or D) being hydrau- lically calculated. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the width of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 16 feet for a 16 ft. x 20 ft. coverage area). Installation The Series LFII (TY1334) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6mm). A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Horizontal Sidewall Sprinklers must be installed in ac- cordance with the following instruc- tions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling with the front edge of the De- flector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench fiats. The Series LFII Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the following in- structions. Step A. Recessed honzontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the wall has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. (Continued on Page 8) Page 4 of 8 TFP4IO ELEVATION Maximum Maximum Coverage Spacing Minimum Flow (c) and Residual Pressure Area (a) Width x Length (b) Ft. (m) Top-Of-Deflector- To- Ceiling: Top-Of-Deflector- To- Ceiling: R. x Ft. 4 to 6 Inches (100 to 150 mm) 6 t 12 inches (100 to 150 mm) (mxm) 155aFI68aC 175°F1790C 155F168°C 175aF/790C 12 x 12 12 12 GPM (45,4 LPM) 12 GPM (45,4 LPM) 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) (3,7 x 3,7) (3,7) 8.2 psi (0,57 bar) 82 psi (0,57 bar) 9.6 psi (0,66 bar) 9.6 psi (0,66 bar) 14 x 14 14 14 GPM (53,0 LPM) 16 GPM (60,6 LPM) 17 GPM (64,3 LPM) 18 GPM (68,1 LPM) (4,3 x 4,3) (4,3) 11.1 psi (0,77 bar) 14.5 psi (1,00 bar) 16.4 psi (1,13 bar) 18.4 psi (1,27 bar) 16 x 16 16 16 GPM (60,6 LPM) 16 GPM (60,6 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) 18.4 psi (1.27 bar) 18.4 psi (1.27 bar) 16x18 16 19 GPM (71,9 LPM) 19 GPM (71,9 LPM) 21 GPM (79,5LPM) 21 GPM (79,5LPM) (4,9 x 5,5) (4,9) 20.5 psi (1.41 bar) 20.5 psi (1,41 bar) 25.0 psi (1,72 bar) 25.0 psi (1,72 bar) 16 x 20 16 23 GPM (87,1 LPM) 23 GPM (87,1 LPM) 26 GPM (98,4 LPM) 26 GPM (98,4 LPM) (4,9 x 6,1) (4,9) 30.0 psi (2,07 bar) 1 30.0 psi (2,07 bar) 38.3 psi (2,64 bar) 38.3 psi (2,64 bar) For coverage area dimensions less than or between those indicated, it is necessary to use the min i m u m r e q u i r e d f l o w f o r t h e n e x t highest coverage area for which hydraulic design criteria are stated. Width (backwail where sprinkler is located) x Length (horizontal throw of sprinkler). Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressu r e s a r e c a l c u l a t e d u s i n g the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. Sidewall sprinklers, where installed under a ceiling with a slope greater than 0 inch rise for a 12 inch r u n t o a s l o p e u p t o 2 i n c h rise for 12 inch run, must be located per one of the following: a Locate the sprinklers at the high point of the slope and positioned to discharge down the slope. Locate the sprinklers along the slope and positioned to discharge across the slope. TABLE A NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR HORIZONTAL CEILING (Maximum 2 Inch Rise for 12 Inch Run) TFP4IO Page 5 of 8 12" ELEVATION Minimum Flow (c) and Residual Pressure (I) Two sprinkler design with the sprinklers at the high point of t h e s l o p e and positioned to discharge down the slope. Maximum Maximum Coverage Spacing Area (a) R. Widthx Length (b) (mx m) (m) Top-Of-Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top-Of-Deflector- To- Ceiling: 6 to 12 Inches (150 to 300 mm) 155°F168°C 175°F/790C 155F/68°C 175°F179°C 12 x 12 12 I 12 GPM (45,4 LPM) I 12 GPM (45,4 LPM) F 13 GPM (49,2 LPM) I 13 GPM (49,2 LPM) (3,7 x 3,7) (3,7) 82 psi (0,57 bar) - 8.2 psi (0,57 bar) - 9.6 psi (0,66 bar) - 9.6 psi (0,66 bar) 14 x 14 14 1 14 GPM (53,0 LPM) I 14 GPM (53,0 LPM) 1 17 GPM (64.3 LPM) 1 17 GPM (64.3 LPM) (4,3 x 4,3) (4,3) 11.1 psi (0,77 bar) - 11.1 psi (0,77 bar) 16.4 psi (1,13 bar) - 16.4 psi (1,13 bar) 16 x 16 16 1 16 GPM (60,6 LPM) I 16 GPM (60,6 LPM) 1 18 GPM (68,1 LPM) I 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 16 x 18 16 I 19 GPM (71,9 LPM) 1 19 GPM (71,9 LPM) F 21 GPM (79,5 LPM) I 21 GPM (79,5 LPM) (4,9 x 5,5) (4,9) 20.5 psi (1.41 bar) - 20.5 psi (1,41 bar). 25.0 psi (1,72 bar) 25.0 psi (1,72 bar) 16 x 20 16 I 24 GPM (90,8 LPM) I 24 GPM (90,8 LPM) 1 26 GPM (98,4 LPM) 1 26 GPM (98,4 LPM) (4,9 x 6,1) (4,9) - 32.7 psi (2,25 bar) - 32.7 psi (2,25 bar) - 38.3 psi (2,64 bar) - 38.3 psi (2,64 bar) For coverage area dimensions less than or between those indicated, it i s n e c e s s a r y t o u s e t h e m i n i m u m r e q u i r e d f l o w f o r t h e n e x t highest coverage area for which hydraulic design criteria are stat e d . Width (backwali where sprinkler Is located) x Length (horizontal t h r o w o f s p r i n k l e r ) . Requirement is based on minimum flow in GPM (LPM) from each s p r i n k l e r . T h e a s s o c i a t e d r e s i d u a l p r e s s u r e s a r e c a l c u l a t e d u s i n g the nominal K-factor. Refer to Hydraulic Design Criteria Section for detail s . . TABLE B NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HO R I Z O N T A L S I D E W A L L S P R I N K L E R S FOR SPRINKLERS AT THE HIGH POINT OF THE SLOPE AND DI S C H A R G I N G D O W N T H E S L O P E (Greater Than 2 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 1 2 I n c h R u n ) Page 6 of 8 TFP4IO 12" ELEVATION Minimum Flow (c) and Residual Pressure Two sprinkler design with the sprinklers located along the slope and positione d t o discharge across the slope. Maximum Maximum Three sprinkler design when there are more than two sprinklers In a compart m e n t a n d Coverage Spacing with the sprinklers located along the slopeand positioned to discharge across t h e s l o p e . Area (a) Ft. Wldthx Length (b) m (x in) (m) Top-Of-Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top-Of-Deflector- To- Ceiling: 6 to 12 inches (100 to 300 mm) 15FI6C 175°F/790C 155Fi68°C 175°FI79*C 12 x 12 12 II 16 GPM (60,6 LPM) 5 16 GPM (60,6 LPM) U 18 GPM (68,1 LPM) II 18 GPM (68,1 LPM) (3,7 x 3,7) (3,7) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 1 14 x 14 14 II 16 GPM (60,6 LPM) II 16 GPM (60,6 LPM) U 18 GPM (68,1 LPM) II 18 GPM (68,1 LPM) (4,3 x 4,3) (4,3) - 14.5 psi (1,00 bar) - 14.5 psi (1,00 bar) - 18.4 psi (1.27 bar) 18.4 psi (1,27 bar) 16 x 16 16 II 16 GPM (60,6 LPM) II 16 GPM (60,6 LPM) II 18 GPM (68,1 LPM) II 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 1 18.4 psi (1,27 bar) 16 x 18 16 iT 22 GPM (83,3 LPM) II 22 GPM (83,3 LPM) U 22 GPM (83,3 LPM) II 22 GPM (83,3 LPM) (4,9 x 5,5) (4,9) 27.4 psi (1,89 bar) 27.4 psi (1,89 bar) 27.4 psi (1,89 bar) 27.4 psi (1,89 bar) 16 x 20 16 In 23 GPM (87,1 LPM) In 23 GPM (87,1 LPM) Il 26 GPM (98,4 LPM) III 26 GPM (98,4 LPM) (4,9 x 6,1) (4,9) 30.0 psi (2,07 bar) - 30.0 psi (2,07 bar) - 38.3 psi (2,64 bar) - 38.3 psi (2,64 bar) For coverage area dimensions less than or between those indicated, it is necessary t o u s e t h e m i n i m u m r e q u i r e d f l o w f o r t h e n e x t highest coverage area for which hydraulic design criteria are stated. Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkle r ) . Requirement is based on minimum flow in GPM (LPM) from each sprinkler. Th e a s s o c i a t e d r e s i d u a l p r e s s u r e s a r e c a l c u l a t e d u s i n g the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.. TABLE C NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZ O N T A L S I D E W A L L S P R I N K L E R S FOR SPRINKLERS LOCATED ALONG A SLOPE AND DISCHARGING AC R O S S T H E S L O P E (Greater Than 2 Inch Rise for 12 Inch Run Up To 4 Inch Rise for 12 Inch Run) TFP4IO Page 7 of 8 12" ELEVATION Minimum Flow (c) and Reèiduai Pressure (LII) Three sprinkler design when there are more than two sprinklers in a c o m p a r t m e n t a n d with the sprinklers located along the slope and positioned to discharge across th e s l o p e . Maximum Maximum Coverage Spacing Area (a) Ft. Width x Length (b) R. x Ft. (mxm) (m) Top-Of-Deflector- To- Ceiling: 4to6 Inches (100to150mm) 155°F168°C 175°F/79C 12 x 12 12 111 16 GPM (60,6 LPM) ifi 16 GPM (60,6 LPM) (3,7 x 3,7) (3,7) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) 14 x 14 14 III 16 GPM (60,6 LPM) III 16 GPM (60,6 LPM) (4,3 x 4,3) (4,3) - 14.5 psi (1,00 bar) - 14.5 psi (1,00 bar) 16 x 16 16 III 16 GPM (60,6 LPM) III 16 GPM (60,6 LPM) (4,9 x 4,9) (4,9) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) 16x18 16 N/A N/A (4,9x5,5) (4,9) 16x20 16 N/A N/A (4,9x6,1) (4,9) For coverage area dimensions less than or between those indicated, it Is necessary t o u s e t h e m i n i m u m r e q u i r e d f l o w f o r t h e n e x t highest coverage area for which hydraulic design criteria are stated. Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). Requirement Is based on minimum flow in GPM (LPM) from each sprinkler. T h e a s s o c i a t e d r e s i d u a l p r e s s u r e s a r e c a l c u l a t e d u s i n g the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.. TABLED NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SI D E W A L L S P R I N K L E R S FOR SPRINKLERS LOCATED ALONG A SLOPE AND DISCHARGING AC R O S S T H E S L O P E (Greater Than 4 Inch Rise for 12 inch Run Up To 8 Inch Rise for 12 Inch R u n ) Page 8 of 8 TFP4IO Care and Maintenance The Series LFII (1Y1334) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability.. Sprinkler Assembly: Series LFIl (TY1334), K=4.2,Residen- tial Horizontal Sidewall Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155'F/68C or Chrome Plated .........P/N 51.211-9-155 155°F168'C White Polyester ......... P/N 51-211-4-155 155°F168'C White (RAL9O1O) ............. P/N 51-211-3-155 155°F/68°C Natural Brass...........P/N 51-211-1-155 175'F179'C or Chrome Plated .........P/N 51-211-9-175 175'F179'C White Polyester.........P/N 51-211-4-175 175'Ff79'C White (RAL9O1O) ............. P/N 51-211-3-175 175°F/79°C Natural Brass...........P/N 51-211-1-175 'Eastern Hemisphere sales only. Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify) finish, P/N (specify). 1/2' (15 mm) Style 20 Chrome Plated .........P/N 56-705-9-010 1/2' (15 mm) Style 20 White Color Coated ................P/N 56-705-4-010 1/2' (15 mm) Style 20 White (RAL9OIO) ............. P/N 56.705-3-010 112 (15 mm) Style 20 Bright Brass Coated................P/N 56-705-2-010 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqLL' /.fire & Buildflng / Th:.:ts Technical Services: Tel: (800) 381-9312/ Fax: ( 8 0 0 ) 7 9 1 - 5 5 0 0 Series TY-FRB - 2.8,4,2 .v 54, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Cove r a g e General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover-age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING" that provides cautions with respect to handling and Instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The. Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TVII31 - Upright 2.8K, 112"NPT TY1231 - Pendent 2.8K, 112"NPT TY2131 - Upright 4.2K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.6K, 1/2"NPT TY3231. Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 314"NPT 1Y4231 - Pendent 8.0K, 314"NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.6 GPM/ps1112 (40,3 LPM/barl12) K = 4.2 GPM/ps1112 (60,5 LPM/bar"Z) K = 5.6 GPM/ps11/2 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM1barl') Temperature Ratings Refer to Table A and B Page 1 of 8 JULY, 2004 ESCUTCHEON 7/16'(11,1 mm) PLATE SEATING • ** NOMINAL SURFACE ,. MAKE-IN Page 2of8 TFPI7I STYLE 10or20 RECESSED ssu ESCUTCHEON DEFLECTOR (11,1 mm) I NOMINAL MAKE-IN AL I 7/16" 1 IIF 'WRENCH 2-3/16" 7 FLATS (55,6 mm) 1/2UNPT** f SSP DEFLECTOR * h"— 2-7/8"(73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression 7- Bushing orifice seat on frame. Screw **pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (771131) AND PEND E N T ( T Y 1 2 3 1 ) S P R I N K L E R S 2,8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16' (11,1 mm) STYLE 10 or 20 PLATE SEAliNG ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR 7/16" 2-3/16' (11,1 mm) 1. J (55,6 mm) NOMINAL MAKE-IN 1-1/2' I I 1]! 3 I V 2- 3 / mm) WRENCH (55,6 mm) FLATS SSP DEFLECTOR* 2-7/8"(73,0 mm) DIA. —"-I 1/2" NPT** I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT ( T Y 2 2 3 1 ) S P R I N K L E R S 4.2K-FACTOR, 1/2 INCH NPT Finishes Bulb ..............Glass Sprinkler: Refer to Table A and B Compression Screw .....Bronze Recessed Escutcheon: White Coated, Deflector.......Copper/Bronze Chrome Plated, or Brass Plated Bushing (K=2.8) .......Bronze Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly ............ Beryllium Nickel w/Teflont Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. .4- SSP DEFLECTOR * h"— 2-7/8" (73,0mm) DIA. 7/16" (11,1 mm) ** NOMINAL NPT MAKE-IN STYLE 100r20 RECESSED ESCUTCHEON WRENCH FLATS ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1-112 (38,1 mm) TFPI7I Page 3 of 8 SSU* DEFLECTOR 7116" (11,1 mm) NOMINAL MAKE-IN - 2-3/16" (55,6 mm) 1/2" NPT** I 6* PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION -Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or a d j a c e n t t o 2- Button Assembly 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB U P R I G H T ( T Y 3 1 3 1 ) A N D P E N D E N T ( T Y 3 2 3 1 ) S P R I N K L E R S 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING ** NOMINAL RECESSED ssu SURFACE MAKE-IN ESCUTCHEON DEFLECTOR 112" 2-5/16" _ NPT (12,7 mm) (58,7 mm) NOMINAL MAKE-IN WRENCH __ 1 (57,2 mm) 3 1-9/16" FLATS (39,7 mm) SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. 3/4" NPT ** I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or a d j a c e n t t o 2- Button Assembly 5-Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provi d e d o n special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UP R I G H T ( T Y 4 1 3 1 ) A N D P E N D E N T ( T V 4 2 3 1 ) S P R I N K L E R S 8.0 K-FACTOR, 3/4 INCH NPT Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler TFPI7I Page 4 of 8 SPRINKLER FINISH (See Nate 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME I PLATED I WHITE POLYESTER 2.8 1/2" PENDENT (TY1231) and UPRIGHT (TY1131) 135"F/57°C Orange 1,2,3,5 155°F168°C Red 175"F/79°C Yellow 200"F/93"C Green 286°F/141 °C Blue NPT 135°F/57°C Orange 1,2,5 RECESSED PENDENT (TY1231)" FIgure 155°F/68"C Red 175°F/79°C Yellow 200°F/93"C Green 135"F157"C Orange RECESSED PENDENT (TY1231)" Figure 6 155°F/68"C Red 175°F/79"C Yellow 200°F/930C Green 42 1/2" NPT PENDENT (TY2231) and UPRIGHT TY2131) 1350F/57°C Orange 1,2 155°F/680C Red 175°F/79"C Yellow 200°F/930C Green 286°F/141"C Blue 135"F/57°C Orange RECESSED PENDENT (TY2231)* Figure 7 155"F/68°C Red 1750F/790C Yellow 200°F/93"C Green 135017/571C Orange RECESSED PENDENT (rv2231)** Figure 8 155°F/68°C Red 175"F/79"C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Resp o n s e Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response S p r i n - klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sp r i n - klers are UL and C.UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20(1/2" NPT) or Style 30(3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Ord e r ) . N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up-right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen-dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, 0r40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been In- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TV-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 2860F/1410C temperature ratings. A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 112 NPT connections. A leak tight 314 TFPI7I Page 5 of 8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME I PLATED I WHITE IPOLYESTER LEAD COATED 5.6 PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1,2,3,4,5,6,7 1,2,3,5 1550F/68°C Red 175°F1790C Yellow 200°F193°C Green 286017/1410C Blue 1/2" NPT 135°F/57°C Orange 1,2,4,5 N/A RECESSED PENDENT (TY3231)" Figure 155"F/68°C Red 175°F1790C Yellow 200"F/93°C Green 135°F/570C Orange 1, 2, 3. 4,5 ( 1,2,4,5 N/A RECESSED PENDENT (TY3231)"" Figure 10 155°F1680C Red 175"F/79"C Yellow 200"F193°C Green 8.0 PENDENT (1Y4231) and UPRIGHT (TY4131) 135°F/57°C I Orange 1.2.3, 4,5,6,7 1,2,5 155"F/68*C Red 1750171791C Yellow 200°F193°C Green 286°F/141°C Blue 3/4" NPT 135017/571C Green 1,2,4,5 N/A RECESSED PENDENT (TY4231)" FIgure 11 155°F/680C Orange 175"F179°C Red 200"F/93"C Yellow 135°F/570C Orange 1,2, 3, 4,5 Green N/A RECESSED PENDENT crv4231r Figure 12 155"F/68°C Red 175°F/79°C Yellow 200°F/930C NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers . Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Q u i c k R e s p o n s e S p r i n k l e r s . Approved by Factory Mutual Research Corporation (FM) as Quick Response S p r i n k l e r s . Approved by the Loss Prevention Certification Board (LPCB Ref. No. 0 0 7 1 4 0 4 ) a s Q u i c k R e s p o n s e S p r i n k l e r s ; h o w e v e r , t h e LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, N e t h e r l a n d s , T e l . 3 1 - 5 3 4 2 8 . 4 4 4 4 / F a x 3 1 . 5 3 . 4 2 8 - 3 3 7 7 ) . Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) a s Q u i c k R e s p o n s e S p r i n k l e r s . Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C - U L L i s t e d , t h e s p r i n k l e r s a r e U L a n d C - U L L i s t e d a s Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be F M A p p r o v e d , t h e s p r i n k l e r s a r e F M A p p r o v e d a s a Corrosion Resistant Sprinklers. * installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjust m e n t R e c e s s e d E s c u t c h e o n , a s a p p l i c a b l e . ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustm e n t R e c e s s e d E s c u t c h e o n , a s a p p l i c a b l e . Frame and Deflector only. Listings and approvals apply to color (Special Or d e r ) . N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 8 2-7/8' DIA. 518t1/4 (73,0 mm) I 314'(19,1 mm) FACE OF _57,2 MOUNTING SPRINKLER / PLATE I (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6.4 mm) I FITTING / I 1/8' L1 (3,2 mm) MOUNTING / L11ji SURFACE CLOSURE SERIES 1-5/16' (33,3 mm) TV-FRB 13/16' (20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT ,,_..2-7/8'DIA. (73,0 mm) I 3/4' (19,1 mm) _____________ (15,9±6.4mm) 2-1/4' DIA. I 1/4'(6,4 mm) I FACE OF MOUNTING (57,2 SPRINKLER PLATE FITTING I MOUNTING SURFACE CLOSURE SERIES 1-114"(31,8 mm) TV-FRB 3t4"(19.1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I 2-7/8' DIA. (73,0 mm) 1/2' (12,7 mm) r (12,7a.2 mm) 2-1/4' DIA. 1/4'(6,4 mm) I FACE OF mm) MOUNTING SPRINKLER PLATE FITTING 1/8' I (2mm) 4I/ SURFACE/ 1-5116".3(33,3 min) / CLOSURE SERIES TV-FRB 1-1/16'(27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. - (73,0 mm) 1/2±1/8' 1/2' (12,7 mm) r (12,7±39 mm) 2-1/4' DIA. 1/4'(6,4 mm) I I SPRINKLER PLATE I I FACE OF E (57,2 mm) -1 MOUNTING I I FITTING 1/8' I (32mm) MOUNTING/ 4 SURFACE SERIES 1-1/4"(311,111 mm) CLOSURE TY-FRB 1'(25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Moth- fled sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the Installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFPI7I 2-7/8' VIA. - 5/8±1/4' (73,0 mm) I 3(4' (19,1 mm) (15,9±6,4 mm) 2-1/4' VIA. 1 1/4' (6,4 mm) I MOUNTING I FACE OF (572 l SPRINKLER PLATE FITTING MOUNTING SURFACE SERIES 1-1/4'(31,8 mm) CLOSURE TY.FRS V'(19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8' VIA. ,u 5/8±1/4' (73,0 mm) 314' (19,1 mm) (15,9±6,4 mm) 2-1/4' VIA. 1/4' (6,4 mm) I FACE OF (57,2 MOUNTING PLATE SPRINKLER I / /_ RUING (3,2 mm) j MOUNTING I SURFACE CLOSURE SERIES 1-5/16' (333mm)1 TY-FRB 13/16' (.6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 7 of 8 - 2-718' VIA. - (73,0 mm) 1/2' (12,7 mm) r (12,7±3,2 mm) - 2-1/4' VIA. 1/4' (6,4 mm) I FACE OF MOUNTING (572mm) PLATE I SPRINKLER FITTING 1/8' #JT MOUNTING SURFACE SERIES 1-1/41(31.8 mm) CLOSURE TYFRB 1' (25.4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' VIA. 1/2±1/8' (73,0 mm) 1/2k (12.7 mm) 1 (12,7±3,2mm) - 2-1/4' VIA. 1/4' (6.4 mm) FACE OF SPRINKLER (57,2 mm) MOUNTING PLATE FITTING 1(8' SURFACE (3,2 mm) \ MOUNTING CLOSURE SERIES 1-5/16' (33,3 mm)] TYFRB 1-1116'(27.0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with WRENCH RECESS (END A USED FOR 1/2' NPT MODELS) WRENCH RECESS (END '8' USED FOR 314' NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH local requirements and/or national codes. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 8 of 8 TFPI7I PIN 57-XXX-X--- XXX L MODEL/SIN 330 2.8K UPRIGHT (1/2NP1) TV1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2NPT) TY2131 341 42K PENDENT (1/2NPT) TY2231 370 5.6K UPRIGHT (1/2NPT) TY3131 371 5.6K PENDENT (1/2NP1) 1Y3231 390 8.0K UPRIGHT (3/4NPT) TY4131 391 8.0K PENDENT (314NP1) TY4231 I I I 155 175 200 286 RATING L 135 SPRINKLER 1 NATURAL BRASS 1 55°F/68°C 4 WHITE POLYESTER 175°FI79C 3 WHITE (RAL9010)* 200°F/93°C 9 CHROME PLATED 286°F/141°C 7 LEAD COATED Eastern Hemisphere sates only. TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure @ontaIabus Local distributor for avail- abilftY.indicate the fuirproduct name. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler With (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2 (15 mm) Style 10 Chrome Plated ............P/N 56-701-9-010 White Coated .............P/N 56-701-4-010 White RALSO1O. ........... PIN 56-701-3-010 Brass Plated ..............P/N 56-701-2-010 1/2 (15 mm) Style 20 Chrome Plated ............P/N 56-705-9-010 White Coated .............P/N 56-705-4-010 White RAL9O1O. ........... PIN 56-705-3-010 Brass Plated ..............P/N 56-705-2-010 3/4' (20 mm) Style 30 Chrome Plated ............P/N 56-705-9-011 White Coated .............P/N 56-705-4-011 White RAL9010. ........... PIN 56-705-3-011 Brass Plated ..............P/N 56-705-2-011 314' (20 mm) Style 40 Chrome Plated ............P/N 56-700.9-010 White Coated .............P/N 56-700-4-010 White RAL9O1O. ........... P/N 56-700-3-010 Brass Plated ..............P/N 56-700.2-010 * Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. tqco Rt & Build ing g tc..icts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-FRB - 56 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 5.6 K-Factor, Hori- zontal and Vertical Sidewall Sprinklers described in this data sheet are quick response - standard coverage, deco-rative 3 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupan- cies such as banks, hotels, shopping malls, etc. They are designed for instal- lation along a wall or the side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desir- able. The recessed version of the Series TY-FRB Horizontal Sidewall Sprinkler is intended for use in areas with a finished wall. It uses a two-piece Style 10 Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjust- ment from the flush sidewall position, or a two-piece Style 20 Recessed Es- cutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush sidewall position. The adjustment IMPORTANT Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and In- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. Corrosion resistant coatings, where Applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any otherauthorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices In proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers 1Y3331 - Horizontal TY3431. Vertical Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 5.6 PM/psi1 (80,6 LPM/barl/2) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Page 1 of 6 JULY, 2004 TFPI76 Page 2 of 6 TFPI76 SPRINKLER FINISH (See Note 11) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED WHITEtm POLYESTER LEAD COATED 5.6 1/2" HORIZ . SIDEWALL (TY3331) 135"F/57°C Orange 1,2.3,4,9,10 1,2,3,9 Blue 1,2,3,9 155°F168°C Red 175°F/79°C Yellow 200°F193"C Green 286°F1141°C NPT RECESSED HORlZ. SIDEWALL (TY3331)" Figure 3 135°F/570C Orange _________ 1,2.4,9.10 1,2,9 N/A 155°F/68°C Red 175"F179°C Yellow 200°F193"C Green RECESSED HORIZ. SIDEWALL (TY3331)* Figure, 4 135"F/57°C Orange 1,2,3,4,9 N/A 155°F/68"C Red 175"F179°C Yellow 200"F/93"C Green 5.6 . NPT - VERTICAL SIDEWALL ",a,) Installed Pendent or Upright 135"F/57°C Orange 5, 6, 7, 8,9 5,6,7,9 155°F1680C Red 175°F179"C Yellow 2000F/93°C Green 286°F/141"C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers for use i n L i g h t a n d O r d i n a r y H a z a r d O c c u p a n c i e s a t a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Listed by Underwriters Laboratories Inc. for use in Canada (C-UI) as Quick Resp o n s e S p r i n k l e r s f o r u s e i n L i g h t a n d O r d i n a r y Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceilin g d i s t a n c e . Approved by Factory Mutual Research Corporation (FM) as Quick Response Spri n k l e r s f o r u s e i n L i g h t H a z a r d O c c u p a n c i e s a t a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04) at a 4 t o 6 i n c h ( 1 0 0 t o 1 5 0 m m ) t o p o f deflector to ceiling distance. The LPC does not rate the thermal sensitivity of ho r i z o n t a l s i d e w a l l s p r i n k l e r s . Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers for use in L i g h t a n d O r d i n a r y H a z a r d O c c u p a n c i e s . Listed by Underwriters Laboratories for use In Canada (C-UL) as Quick Response S p r i n k l e r s f o r u s e i n L i g h t a n d O r d i n a r y H a z a r d Occupancies. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers f o r u s e i n L i g h t H a z a r d O c c u p a n c i e s . Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06 & 0 0 7 a 1 0 4 ) a s Q u i c k R e s p o n s e S p r i n k l e r s . Approved by the City of New York under MEA 354-01 -E. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) a t a 4 t o 6 i n c h ( 1 0 0 t o 1 5 0 m m ) t o p o f deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horiz o n t a l s i d e w a l l s p r i n k l e r s . Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL L i s t e d , t h e s p r i n k l e r s a r e U L a n d C - U L L i s t e d as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM A p p r o v e d , t h e s p r i n k l e r s a r e F M A p p r o v e d a s Corrosion Resistant Sprinklers. * Installed with Style 10(1/2" NPT) 3/4" Total Adjustment Recessed Escutcheon. Installed with Style 20(1/2" NPT) 1/2" Total Adjustment Recessed Escutcheon. Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflonf Bulb ...............Glass Compression Screw .....Bronze HSW Deflector ........Bronze VSW Deflector ........Copper Patents U.S.A. 5,810,263 Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. TFPI 76 Page 3 of 6 DEFLECTOR '\ HAT --. 6* 4 2 3 1 9/16" WRENCH 1/2" ** (14,3 mm) FLATS NPT I 1-13/16' 1 mm 7/16' I r'(46,0 mm) (11 1 , _____ ) CENTERLINE NOMINAL OF SPRINKLER MAKE-IN I WATERWAY I - 1-1/2 (38.1 mm)""l 2-3/16" (55,6 mm) STYLE ESCUTCHEON 10 0r20 - PLATE SEATING L RECESSED SURFACE ESCUTCHEON 1 - Frame 2- Button 3-Sealing Assembly 4-Bulb 2-7/8" DIA. 5-Compression (73,0 mm) Screw 6- Deflector * Temperature rating Is indicated on deflector or adjacent to orifice seat on fr a m e . **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLER S Design Criteria The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers are in- tended for fire protection systems de- signed in accordance with the stand- ard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the re- quirements of NFPA 13, and FM Ap- proval is based on the requirements of FM's loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Es- cutcheon, as applicable, is to be used for recessed horizontal installations. installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 inch (2,4 mm) for the 286°F/1410C temperature ratings. A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. Higher levels of torque may distort the sprinkler and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Horizontal and Vertical SIdewall Sprinklers must be installed in accordance with the follow- ing instructions. Step 1. Horizontal sidewall sprinklers are to be Installed In the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright po- sition with the arrow on the Deflector pointing away from the wall. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 5), With reference to Figure 1 or 2, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series TY-FRB Recessed Hori- zontal Sidewall Sprinklers must be installed in accordance with the follow- ing instructions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 10 or 20 Mounting Plate over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 6). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- Page 4 of 6 TFPI76 plied, slide on the Style 10 or 20 Clo- sure over the Series TY-FRB Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling Care and Maintenance The Series TY-BFR Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, mustbe re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner Is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or compo- nents manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and compo- nents which have been subject to mis- use, improper installation, corrosion, or which have not been installed, main- tained, modified or repaired in accord- ance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL ARROW MUST POINT AWAY 7/16' FR BE ESCUTCHEON (11.1 mm) PERPENDICULAR OM AND PLATE SEATING 1/2' ** NOMINAL TO THE BACK SURFACE MAKE-IN WALL SURFACE j) 216' \ NPT IWRE _ 1I"11'1\ 2-3/16' jIlt 1-1/2' (55,6 mm) NCH mm): (38,1mm) FLATS LI SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION 1 - Frame 3-Sealing 4-Bulb 6- Deflector 2- Button Assembly 5-Compression 7- Election Spring Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB VERTICAL SIDEWALL (TY3431) SPRINKLERS TFPI7G Page 5 of 6 - 5/8±1/4" (15,9±6,4 mm) MOUNTING FACE OF SURFACE _ SPRINKLER FITTING CLOSURE 2-7/8" DIA. (73,0 mm) SERIES TY-FRB 2-1/4" DIA. m (57,2m) MOUNTING PLATE (3,2 mm) I 1-1/4"(31,8mm) . 314"(19,1 mm) 314'(19,1 mm) 1/4" (6,4 mm) FIGURE 3 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 1/2±1/8" I (12,7±3,2 mm) MOUNTING I I FACE OF SURFACE SPRINKLER - 1 FITTING CLOSURE 2-7/8" DIA. (73,0 mm) SERIES TY-FRB 2-1/4"DIA. (57,2 mm) MOUNTING PLATE (3,2 mm) 1-1/4'(31,8 mm) 1/2"(12,7mm) 1' (25,4 mm) 1/4'(6,4 mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRI N K L E R WITH 7W0-PIECE 1,2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON WRENCH RECESS (END 'A" USED FOR 1/2 NPT MODELS) FIGURE 5 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS V PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 W-TYPE 7 RECESSED SPRINKLER WRENCH DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. RATING 135 1 135017/570C 155 155F/68"C 175 175F/79"C 86 F uj 200°F193°C 286°F/141°C Page 6 of 6 TFPI76 P/N 57-XXX-X-XXX I SPRINKLER MODEL/SIN I. 378 HORIZONTAL SIDEWALL TV3331 1 NATURAL BRASS 375 VERTICAL SIDEWALL TY3431 4 WHITE POLYESTER 3 WHITE RAL9010) 9 CHROME PLATED 7 LEAD COATED TABLE B * Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TV-FRB (specify Horizontal Sidewall or Vertical Sidewall) Sprinkler with (specify type of finish or coating), P/N (specify from Table B). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2" (15 mm) Style 10 Chrome Plated.........P/N 56-701-9-010 1/2" (15 mm) Style 10 White Color Coated ...............P/N 56-701-4-010 1/2" (15 mm) Style 10 White RAL90I0" .......PIN 56-7013-1 1/2" (15 mm) Style 10 Brass Plated...........P/N 56-701-2-010 1/2" (15 mm) Style 20 Chrome Plated .........P/N 56-705-9-010 1/2" (15 mm) Style 20 White Color Coated ...............P/N 56-705-4-010 1/2" (15 mm) Style 20 White RAL90I0" .......P/N 58-705-3-010 1/2" (15 mm) Style 20 Brass Plated...........P/N 56-705-2-010 Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 'See Fire Protection Submittal Sheet for Pressure Rating and l..istinglApproval Information ttICU /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www:tyco-fire.com Tyco Fire Products Model BFV-1 Butterfly Valve General Description The Model BFV-1 Butterfly Valve is specifically designed to provide for ef- ficient control of fire protection water supplies. The Model BFV-1 is designed to meet the increasing pressure re- quirements of the Fire Protection In- dustry with a maximum operating pres- sure of 300 psi. Flow may be from either direction, and the valves may be positioned in any orientation. The valve is furnished with grooved ends for use with grooved couplings and can be easily adapted to flanged components utilizing Grinnell Figure 71 Class 150 flange adapters. The body and disc construction provides for increased strength and durability. The Model BFV-1 Butterfly Valve is provided with 2 sets of SPDT Supervisory Switches for use in outdoor and indoor applica- tions. A high strength stainless steel upper stem is provided for depend- ability. The surfaces at the upper stem and lower trunnion areas incorporate a reduced dynamic torque and anti- compression set design to ensure low operating torque and increased seal longevity. This unique Tyco design feature pre- vents elastomeric failure of the disc encapsulation that is commonly expe- rienced with other manufacturers. This is accomplished by providing uniform compression throughout the opening and closing operation of the disc. The Model BFV-1 Butterfly Valves are a redesignation for the Central Figure 570, Central Figure 580 and Grinnell Figure 580. WARNING The Model BFV-1 Butterfly Valve de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of this device. The owner is responsible for maintain- ing his fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Technical Data Model: BFV-1 Sizes: 2-1/2", 3", 4", 5", 6", 8" & 10" Maximum Working Pressure: 300 psi (2068 kPa) Factory Hydro Test: 100% at 600 psi (4137 kPa) in accordance with test requirements of MSS SP-67, UL, FM and ULC Approvals: UL, FM and ULC for both indoor and outdoor use. Note: 8" - 10" are FM approved only. See Fire Protection Submittal Sheet for exact Listing / Approval information. Materials of 'Construction: Body: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Epoxy Disc: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Disc Seal: Grade EPOM uEencapsu. lated rubber conforming to ASTM D-2000 Upper Stem: Type 440 Stainless Steel (2-1/2'-8") Type 17-4 Stainless Steel (10") Lower Plug and Stem: Type 17-4 Stainless Steel Operator: Gear operator with iron housing coated with Epoxy Bracket: Steel - Black Zinc Plated Ordering Information When placing an order, indicate the full product name. Please specify the quantity, valve model number, size, type of seal; EPDM "E", and part number from the follow- ing list. Valve Valve Size Part Number 2-1/2" 59-300-F-025 59-300-F-030 59-300-F-040 S. 59-300-F-050 6" 59-300-F-060 8" 59-300-F-080 10" 59-300-F-100 Tyco Fire Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in accordance with the applica- ble standards of the National Fire Pro- tection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Page 1 of 2 JANUARY, 2005 TFPI530 Supervisory Tamp Switch Circuits (Valve Fully Open) NC NO arm Switch Rating: Panel 1 O 125, 250 VAC isory I 0.25A 250 VDC 0.50A 125 VOC End of Line Resistance Or, Next Device NC 1K! R Voltage HASSIS 00M NO ( tORN Source T!ORN Auxiliary WIRINGj DIAGRAM =1 Utilization and Connection of Auxiliary Switch to be Reviewed and Approved by the Local Authority Having Jurisdiction Front view with valve Open Side view with valve open Nominal Dimensions Approx. Weight Size A B C D E F G Inches Inches Inches Inches Inches Inches Inches Inches lbs. MR? mm mm mm mm mm mm mm Kg. 21/2" 5.08 10.41 6.97 2.88 3.81 5.72 12.0 73.0 129.0 264.4 177.0 73.0 96.8 145.3 " 5.4 5.41 11.38 7.29 3.50 3.81 5.72 14.0 88.9 1 137.4 289.11 185.2 88.9 1 96.8 145.3 kuIA* " 6.4 6.37 12.70 825 4.75 1 4.56 5.72 22.0 114.3 161.8 322.6 209.6 120.7 115.8 145.31 "A' 10.0 5 7.33 14.56 10.41 6.25 5.81 6.18 141.3 1862 369.8 264.4 158.8 147,6 157.0 N/A 31.0 14.1 6' 7.62 15.23 10.70 6.75 5.81 6.18 36.0 168.3 193.5 386.8 271.8 171.5 147.6 157.0 '"A' " 16.3 an 9.24 17.50 13.37 10.00 5.25 6.43 1.22 52.0 219.1 234.7 444.5 339.6 254.0 133.4 163.3 31.0 23.6 10' 11.81 21.78 16.93 12.00 625 7.96 1.75 75.0 273.0 299.9 553.2 430.0 304.3 158.8 2022 44.5 34.1 Friction Resistance Size Equiv. Length in Feet 2W 6' 3' 7' 6' 10' 13' 8' 14' 10' 16' Note: Friction Resistance is specified in equivalent length of Std. weight (C-120) steel pipe. Page 2 of 2 TFPI53O Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Model BFV-1. Butterfly Valve * End of disc does not extend beyond valve body. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and underst a n d t h e S Installation instructions (IH-1000). Never remove any piping component or correct or modify any piping 001 deficiencies without first depressurizing and draining the system. Material and gasket sel e c t i o n s h o u l d b e verified to be compatible for the specific application. Ceflifled Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 NORYL, NSF Listed Stainless Steel, 300 Series EPDM (FDA approved) Buna Nitrile (FDA approved) NORYL, NSF Listed Stainless steel, braided hose QF C D Fasteners & Springs Elastomers Polymers Sensing line MODEL 375ADA MODEL 375ADAG [e] FEATURES Sizes: 0 4" 0 6" 0 8" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 OPTIONS (Suffixes can be combined) Class 125 O - with flanged end OS & Y gate valves (standard) O L - less shut-off valves (grooved body connections) 0 LM - less water meter O - with remote reading meter O - with gpm meter (standard) O - with cu ft1min meter O G - with grooved end OS&Ygate valves O FG - with flanged inlet gate connection and grooved outlet gate connection O MS - with Integral Relief Valve Monitor Switch OBGVIC - with grooved end butterfly valves (See document #BF-375ADABGVlCfordimensions and approval status) ACCESSORIES O Air gap (Model AG) O Repair kit (rubber only) O Thermal expansion tank (Model WXTP) O OS & Y Gate valve tamper switch (OSY-40) O QT-SET Quick Test Fitting Set DlMENSlONS& WEIGHTS (do not include MODEL wmiour I WITH os&y WITH os&v SIZE I GATES GATES (G)) I GATES (G)G) in. I mm I lbs. kg lbs. kg lbs. kg 4 100 98 45 252 114 226 103 6 150 151 69 387 176 357 162 MODE. B LESS E E S2E A GATE D OS&Y OS&Y VALVES OPEN CLOSED UBMI I IAL SHEET APPLICATION Designed for installation on potable water lines in fire pro- tection systems to protect against both backsiphonage and backpressure of contaminated water into the potable wa- ter supply. The Model 375A0A shall provide protection where a potential health hazard exists. Incorporates metered by- pass to detect leaks and unauthorized water use. STANDARDS COMPLIANCE (unless otherwise noted, applies to sizes 4" thru 8") ASS E® Listed 1047 CSA® Certified UL® Classified (size 4" & 6") C-UL® Classified (size 4" & 6") FM® Approved Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California MATERIALS Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Internals Stainless steel, 300 Series i. Inini in. I mm I in. in. Imml in. Inril E. l,yrnl. in. Inmi in. Inmi i. Inmi in. '' T- - ---- - 400 800 1200 1600 FLOW RATES (GPM) C, 15 ci) 0. U) ci) 9 Ui Ce co Ui 19 - 10 1u'I 0. C, a) U) 9 Ui a) IL FLOW CHARACTERISTICS MODEL 375ADA 4" & 6" (STANDARD & METRIC) FLOW RATES (Us) 25.2 50.5 75.7 101 20 15 10 5L 0 MODEL 375ADA 8" (STANDARD & METRIC) FLOW RATES (I/s) 63.1 126.2 189.3 252.4 - =.— 1000 2000 3000 4000 FLOW RATES (GPM) *Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instruc- tions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clear- ance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. I PROTECTIVE OUTDOOR INSTALLATION (MODEL 375ADAVIC) SPECIFICATIONS Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 1 450 675 1 900 1351 8" 1 780 1169 1 1559 - 2339 10" 1 1229 1843 2458 3687 DIRECTION OF FLOW c) INDOOR INSTALLATION (MODEL 375ADAG) The Reduced Pressure Detector Backflow Prevention Assembly shall be ASSE® Listed 1047, and sup p l i e d w i t h f u l l p o r t OS & V gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 5 3 6 G r a d e 4 ) , t h e s e a t ring and check valve shall be NORYL,the stem shall be stainless steel (ASTM A 276) and the seat d i s c e l a s t o m e r s s h a l l be EPDM. The checks and the relief valve shall be accessible for maintenance without removing t h e d e v i c e f r o m t h e l i n e . The Reduced Pressure Detector Backflow Prevention Assembly shall be a WILKINS Model 375ADA . Page 2 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zum.com (E)POTTER The Symbol of Protection U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50mm thru 200mm). LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die- cast housing. The cover is held in place with two tamper resis- tant screws which require a special key for removal. A field in- stallable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD UL,ULCandCSFMUsted,FMandLPCBApproved,NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI (31 BAR) Minimum Flow Rate forAlarm: IOGPM (38 LPM) Maximum Surge: 18 FPS (5,5 m/s) ContactRatings: Two sets of SPDT (Form C) 15.0 Amps at 1251250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA 4/I P54 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/1200F, 4,50C1490C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: SteelPipe schedules 10 thru 40, sizes 2"thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-1 3 One or two family dwelling NFPA-1 3D Residential occupancy up to four stories NFPA-1 3R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be in- stalled within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of.a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a dis- tance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the watertlow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8800001 - REV W PAGE 1 OF 2 MFG. #5400761 - 7/02 FIG. 4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. OW!. fi61-4 (E)POTTER The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME FIG. I SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL orG. 1923-5 CAUTION: An uninsulated section of a single conductor should not be looped around the termi- nal and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FlG.2 OPTIONAL TAMPER SWITCH RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS. A B SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO 8. TO INSTALL, DRILL HOLE AS INDICATED: PIPE SIZE HOLE SIZE to 2 1/2" I 1/4" +1/8" -1/16" (50mm to 65mm) (33mm ±2mm) to 8" 2 ±1/8" (80mm to 200mm) 50mm ±2mm) Cover Tamper (with cover in place) DIRECTION OF WATERFLOW C NO WC (*141) (9(0) COlA) W. fullawl DWG. 1761-30 TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL SOFI.-LBS (68 n-m) OF TORQUE MOUNT ON PIPE 50 ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) 0 0 1 A 10-25 B 20-40 C 1-15-01 DIE 50-70 FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: The Model VSR-F has two switches, one can be used to 2 01 operate a central station, pro- IMLV Cfl4Cl9 aos CU MAW ir z€ FROM prietary or remote signaling unit, while the other contact is used to operate a local audible __________ ____________ or visual arinunciator. J JiJ in A condition of LPC Approval of this product is that the electri- 1IC IC NC IC WBI*IGS WNW or 114! *11104 FOR OR ' '° cal entry must be sealed to NI MOBIl orOBICIl. nc COW AK CCAnC 0! or *1nBIi. oc exclude moisture. IC.II! . I CXV=C II "C ("-2 For supervised circuits see "Switch Terminal Connec- tions" drawing and caution note (Fig. 1). APPLICATION WARNING I Due to the possibility of unintended discharges caused by pressure surges, trapped air, or sho r t r e t a r d t i m e s , w a t e r f i o w s w i t c h e s that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device t o d i s c h a r g e A F F F , d e l u g e , o r chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitori n g s y s t e m s h o u l d b e in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch l i n e , s h o u l d a l w a y s b e u s e d f o r test purposes. If there are no provisions for testing the operation of the flow detection device on the sy s t e m , a p p l i c a t i o n o f t h e VSR-F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system t h a t t h i s s y s t e m m u s t b e tested in accordance with the testing instructions. PRINTED IN USA MKr. #8800001 -REV W PAGE 2 OF 2 MFG. #5400761 - 7/02 I 6" BELL SHOWN Notes: Minimum dB ratings are calculated from integrated sound pressure measurements m a d e a t U n d e r w r i t e r s L a b o r a t o r i e s a s specified in UL Standard 464. UL temperature range is -30° to 150°F (-340 to 660C). Typical dB ratings are calculated from measurements made with a conventional sound l e v e l m e t e r a n d a r e i n d i c a t i v e o f output levels in an actual installation. SUE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENT (MAX.) TYPICAL dB AT 10 FT. (3m)(2) MINIMUM dB AT 10 FT. (3m)(1) 8(180) 12VDC P8D126 1708012 .12A 85 76 8(200) 12VOC P00128 1108012 .12A 90 16 10(250) 12VOC PBD1210 1710012 .12A 92 76 6(150) 24V0C P00246 1706024 .06* 87 76 8 (200) 24VDC P8D248 1708024 .06* 91 79 10(250) 24V0C P802410 1710024 .06* 94 79 $ (150) 24VAC P8A246 1808024 - .17* 91 76 8(200) 24VAC PBA248 1808024 .17A 94 76 10(250) 24VAC P8A2410 1810024 .17A 94 76 6(150) 120VAC P0*1206 1806120 .05* 92 82 8(200) 12OVAC P0*1208 1808120 - .05* 99 82 10(250)_- 120VAC P8A12010 1810120 .05* .99 85 BELLS (E)POTTER PBA-AC & PBD-DC The Symbol of Protection UL Listed, FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurgiarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devic e s . T h e y h a v e l o w p o w e r c o n - sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square el e c t r i c a l b o x f o r i n d o o r u s e o r o n a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox mo d e l B B K - 1 , S t o c k N o . 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Electric Signal Company' 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8850001- REV Q - PAGE 1 OF 2 MFG. #5400776 -12101 FIG. I BELLS 2 11/16 (68) ORG. 1776-I FIG. 2 WEATHERPROOF BACKBOX BOXHASONEThREADED 1/2"CONDUITENTRANCE ORG. p776-2 LP3 3/8 (86) 4 1/4 (108) L r (250) BELLS - ®POTTER The Symbol of Protection DIMENSIONS INCHES (mm) FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (Ia.RM (OUT) WHITE (IN) WHITE (OUT) FROM CONTROL PANEL TO NEXT BEIj. FROM CONTROL PANEL OR OR END-W-4ME OR PRECEDING ecu.RESISTOR PRECEDING SELL 8LACK jcic (OUT) BLACK ON) BLACK (OUT) WHEN ELECTRICAL SUPERVISKIN IS REQUIRED USE IN AND OUT EUCS AS SHORN, NOTES: OBSERVE POLARITY TO RING D.C. BELLS. RED WIRES POSITIVE (+) BLACK WIRES NEGATIVE (-) WHEN ELECTRICAl. SUNERAISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2. END-OF-UNE RESISTOR IS NOT REQUIRED ON A.C. BELLS. DWG. #776-3 INSTALLATION The bell should be mounted a minimum of 8 ft. (2,4m) from the floor or as close to the ceiling a s p o s s i b l e . Removethegong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing d o w n ) . Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in th e h o l e i n t h e g o n g ) . Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 -REV Q PAGE 2 OF 2 MFG. #5400776-12/01 SchedulemlO"/Schedule w40" Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-1O/Schedule-40 sprinkler pipe you g e t a U L l i s t e d a n d F M a p p r o v e d p r o d u c t . A l t h o u g h t h e s e products do not require separate approvals, Schedule-10/Schedule - 4 0 g i v e s y o u t h e e x t r a q u a l i t y a s s u r a n c e y o u d e m a n d . Our Sch-10 (l"- 8") pipe and Sch40 (1"- 2l4) pipe have passed the same thorough lab testing as our other liste d p i p e products, and receive periodic mill inspections from both UL and F M a g e n t s t o e n s u r e c o n s i s t e n t q u a l i t y . E0I.1TEtT1r.ii. NPS Nominal I.D. WI. WI. (H20 Filled) Pal WVLift (21') WVUft (24') Wt&lft (25' In; mm In; mm Lbs/Ft; Kg/rn Lbs/fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1114, 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1W 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 763 30 1,043 1,192 1,242 2W 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10I.1TT NPS Nominal I.D. WI. M. (1120 Filled) Pcsf Wlllift (21') WtIUft (24') Will: (25' In; mm In; mm LbslFt; Kg/rn LbslFt; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 11 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1W 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1W 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2W 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 2095. 24.5 59.75 7 1,100 1,256 1,309 Schedule-I0/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications ofASTM A-123. Superior Coating Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American IMade T[ Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tilCo/Flow Control allied TUBE & CONDUIT Listed Approved Listed 16100 S. Lathrop. Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708439.1806 tt,cI3 re & Building. .1 Products : Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittin g s General Description See Fire U' Td] t°O' Pressure Rating and Listing/Approval YL L Information The grooved fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping grooved piping systems. Grooved fittings are available in durable ductile iron or fabricated steel as indicated. Note: Figure 510S and 519S fillings are special short radius fittings with smaller center to end dimensions than standard grooved fittings. Depending on the size and coupling used, there may be interferences at the bolt pads that require repositioning of the coupling orientation. The use of flange adapters is not recommended with Figures 510S and 5193 fittings. Contact Tyco Fire Products for details. WARNING The Fittings described herein must be installed andniaintainedlncompIiancewithtbisdocumen as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may Impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The instilling contractor or sprinkler manufacturershould be contacted with any questions. Technical Data Approvals: UL, FM, ULC, VdS, and LPCB; Note: See Fire Protection Submittal Sheet for exact Listing I Approval information. Material: Cast: FIgures: 201, 210,219,250,260,501,510, 519, 51 ODE. 501S, 510S and 519S - Ductile iron conforming to ASTM A-536, Grade 65-45-12 Fabricated Steel: Figures 391, 392, 393, 312, 313, 321, 327, 341 and 350 - Carbon Steel, (Sizes 11/4' -6' are Schedule 40); (Sizes 8'- 12' are Schedule 30), conforming to ASTM A-53 Grade B Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity,figure number, wall thickness, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughouttheU.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Are Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractororproductmanulacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid forand property installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwtthlyco Fire Products orfor productsand components which have been subject tomisuse,improperinstallation,corrosion,orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), andlorthestandanisofanyotherAuthorities Having Jurisdiction. Materials found bylyco Are Products to be defective shall be eitherrepaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit, anyotherobligation in connection with the sale of products or parts of products. Tyco Fire Productsshatnotberesponsibleforsprinldersystem designerTorsorinaccurBteorincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES,INCUJDINGBUTNOT LIMITED TO LABOR CHARGESi REGARDLESS OF WHETHER1YCOFIREPRODUC1SWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALL1YCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. )7IEFIYIEGOING WARRJNTf IS Mr1DE LV lIEU OF U1L Page 1 of 6 September 2004 TFPI8IO Figure 210 Figure 260 Figure 219 Friction Resistance* (Expressed as Equivalent Straight Pipe) Elbow The 900 450 Branch Run Size Feet Feet Feet Feet Inches MM Meters Meters Meters Meters 1¼ 1.9 1.0 4.8 1.9 42.4 0.6 0.3 1.5 0.6 1Y2 2.3 1.2 5.8 2.3 48.3 1 0.7 0.4 1 1.8 0.7 2 3.2 1.6 8.0 32 60.3 1.0 0.5 2.5 1.0 2V2 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 1.2 76.1mm 4.1 2.1 10.3 4.1 1.2 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1.5 108.0mm 6.5 3.3 16.3 6.5 2.0 1.0 5.0 2.0 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 133.0mm 8.0 4.0 20.0 8.0 2.4 1.2 6.1 2.4 8.0 4.1 20.0 8.0 139.7..l 2.4 1.3 6.1 2.4 5 8.2 4.1 20.5 8.2- 141.3 2.5 1.3 6.3 2.5 159.OMM 9.5 4.8 23. 9.5 2.9 1.4 7.2 2.9 165.1 mm 9.5 4.8 T --T5- 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 3.0 1.5 1 7.6 3.0 216.3mm 13.1 6.6 32.8 13.1 4.0 2.0 10.0 4.0 8 13.1 6.6 32.8 13.1 219.1 4.0 2.0 10.0 4.0 10 16.5 8.3 41.3 16.5 273.0 5.0 2.5 12.6 5.0 12 19.9 1 9.9 49.7 1 19.9 323.4 6.1 3.0 15.1 6.1 Figure 201 Figure 210 Figure 219 Figure 2601 45° Elbow 90° Elbow Tee End Cap APPX. Wt. 1T Appx. Wt. Appx. Wt. Wt. Nominal Inches Lbs. Inches Lbs. InchesLbs.Size Inches Lbs. rpx. mm Kg. mm Kg. mm Kg. mmKg. T7 0.9 17 1.0 i7 1.4 W. 0.4 44.5 0.4 69.9 0.5 69.9 0.6 22.4 0.2 V/a" 1.75 1.1 1.2 1.8 1W 0.6 44.5 0.5 69.9 0.5 69.9 0.8 22.4 0.3 2 • T 1.8 r 2.0 2.7 äW 0.9 50.8 0.8 82.6 0.9 82.6 12 22.4 0.4 2'I2" 2.2 äYr 3.0 5.8 -:a - 0.9 57.2 1.0 95.3 1.4 95.3 2.6 22.4 0.4 2.2 3.0 5.8 -u:- 1.1 76.1mm 57.2 1.0 95.3 1.4 95.3 2.6 23.9 0.5 • 3.5 4.5 7.0 ä i.i 63.5 1.6 108.0 2.0 108.0 3.2 22.4 0.5 108.0mm 2.88 5.5 8.5 11.5 - 730 2.5 120.7 3.9 120.7 5.2 - - • 5 5.2 8.5 11.8 T 2.6 76.2 2.4 1 127.0 3.9 127.0 5.4 25.4 1.2 3.25 7.7 5.25 11.3 5.25 10.6 - 1.0mm 82.6 3.5 133.4 5.1 133.4 4.8 - - 7.7 11.3 15.3 4.7 139.7mm ______ 82.6 3.5 139.7 1 5.1 139.7 69 23.4 2.1 • 8.5 5 13.5 17.0 1 - 5.0 82.6 3.9 139.7 6.1 139.7 7.7 25.4 2.3 159.0mm 3.50 12.0 6.00 14.6 6Z 13.9 - 88.9 5.4 152.4 6.6 152.4 6.3 - - 3,50 12.0 6.50 18.5 5 26.0 1.00 7.5 165.1mm 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 -: 12.0 18.5 26.0 1.00 7.5 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 4.25 23.0 r 36.5 45.0 - 216.3mm 108.0 10.4 196.9 16.6 196.9 20.4 - - 8. T 23.0 36.5 45.0 1.19 12.8 108.0 10.4 196.9 16.6 196.9 20.4 30.2 5.8 T 31.0 60.0 W 72.1 1.25 20.0 10 120.7 14.1 228.6 272 228.6 1 32.7 31.8 9.1 [_ 5.25 40.0 15 67.0 15 92.5 1.25 36.o 12, 2 1334 18.1 254.0 30.4 254.0 42.0 31.8 16.3 Available with tapped plugs, contact Tyco Fire & Building Products. 'o F2 Figure 201 Page 2 of 6 TFP1810 Figures 201,210, 219, and 260 For reducing tees and branches, use the value that is corresponding to the branch alse Example: for 8' x 8" x 2" tee, the blanch value 2. Is 8.0 feet Friction resistance for all elbows and tees except Figures 5108 and 5i9S. No Figure 51IS and 5195f1t jsarsspsclal itaitradlus tngswithsm Ii roenterto end dimensions than standard grooved flwngs. Depending on the size and coupling used, there may be Intertemnces itO,r bolt pads which requires repositioning of the coupling orientation. The use of l h a n g e a d a p t e r s I s not recommended with Figures 510$ and 519$ fittings. Contact Tyco Fire Products for dahlia. Figure 501S Figure 510S Figure 5198 450 Elbow 900 Elbow Tee Nominal C to E Appx Wt. C to E Appx. Wt. C to E Appx. Wt. size Inches Lbs. Inches Lbs. Inches Lbs. mm Kg. mm Kg. mm Kg. 2 • 1.8 1.5 2.75 2.1 50.8 0.8 69.9 0.7 69.9 1.0 2'!? 2.25 2.2 50 2.2 7 3.0 57.2 1.0 76.2 1.0 76.2 1.4 76 1 225 "°' 22 -:or 2.3 3.1 572 1.0 76.2 1.0 1.4 • 3.0 4.1 ' 63.5 1.6 85.9 1.3 t4.00 1.9 • 52 :o 5.6 7.7 76.2 2.4 101.6 2.6 3.5 1397 3.25 7.7 r 8.6 . 12.0 82.6 3.5 124.0 3.9 124.0 5.4 325 8.5 -r 8.8 4.88 12.0 82.6 3.9 124.0 3.9 124.0 5.4 165.1mm Tö 12.0 5.50 11.00 5.50 15.0 88.9 5.4 139.7 5.0 139.7 6.8 6 • 12.0 ö 11.2 5.50 152 88.9 5.4 139.7 5.1 139.7 6.9 8 • 23.0 iW 23.4 312 108.0 10.4 1748 10.6 1748 14.2 Page 3 of 6 TFP1S1O Figures 501,510,519 and 51 ODE .- CtoE Figure 510 !C to E_.j AE Figure 519 1ff'T'TL 'toE Figure 51 ODE Figure 501 Figure 501 Figure 510 Figure 519 1 Figure 51ODE 450 Elbow 90° Elbow Tee 90° Drain Elbow Nominal C to Appx. Wt. C to E Appx. Wt. Appx. Wt. C to E A B 1LppL Wt size Inches Lbs. Inches Lbs. Inches Lbs. Inches Inches Inches Lbs. mm Kg. mm Kg. mm Kg. mm mm mm Kg. • 11/44.5 4, 1.75 0.9 2.75 1.0 2.75 1.4 0.4 69.9 0.5 69.9 0.6 - - - 1 h 1.75 1.1 2.75 1.2 2.75 1.8 44.5 0.5 69.9 0.5 69.9 0.8 • 2.00 1.8 3.25 2.0 3.25 2.7 50.8 0.8 82.6 0.9 82.6 1.2 - - • 2,2 2.25 2.2 3.75 3.0 3.75 5.8 3.75 2.00 2.75 2.7 57.2 1.0 95.3 1.4 95.3 2.6 95.3 50.8 69.9 1.2 ,. .s r -r 7.0 4.25 2.34 3.7 63.5 1.6 108.0 2.0 108.0 3.2 108.0 59.4 69.9 1.7 • 3.00 5.2 5.00 8.5 5.00 11.8 5.00 2.85 2.75 7.0 ' 76.2 2.4 127.0 3.9 127.0 5.4 127.0 72.4 69.9 3.2 • 8.5 &r 13.5 17.0 & U T7 13.0 82.6 3.9 139.7 6.1 139.7 7.7 139.7 85.9 69.9 5.9 T5 12.0 55 18.5 T5 26.0 W -: 13.4 88.9 5.4 165.1 8.4 165.1 11.8 165.1 99.6 69.9 6.1 80 23.0 7 36.5 7 45.0 77 2.75 26.3 108.0 10.4 196.9 16.6 196.9 20.4 196.9 125.7 69.9 11.9 Figures 501S9 510S and 519S CE J!,NDE Figure 501S Figure 510S° Figure 519S° Friction Resistance 501S, 5108 & 519S (Expressed as Egulvale,t Straight Pipe) Elbow The Size .900 45* Brmanch Ru Feet Feet Feet Feet Inches MITI Meters Meters Meters Meters 2 3.2 1.6 8.0 32 60.3 1.0 0.5 2.5 1.0 2Y2 3.9 2.0 W 3.9 73.0 1.2 0.6 1 3.0 1.2 76.1.. -- -- r 4.1 12 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1.5 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 19 7 °°° 8.0 4.1 20.0 8.0 2.4 1.3 1 6.1 2.4 5 ir i:T- -r --- -8.2 141.3 2.5 1.3 6.3 2.5 9.5 4.8 23.8 9.5 165 1 °°° 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 3.0 1.5 8 6.6 itt 219.1 4.0 2.0 Figure 250 Cast EffB Figure 350 Fabricated Sizes 3" to 6" 1.-E to E-1 BE Figure 350 Fabricated Sizes 8" to 12" Page 4 of 6 TFP181O Figures 250 and 350 Figures 250 and 350 Concentric Reducer - Groove x Groove Nominal E to E Appx. Wt. Nominal E to E Appx. Wt. Nominal E to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Size Inches Lbs. Inches mm Kg. Inches mm Kg. Inches mm Kg. 2.50 1.0 3.50 4.2 4.00 5.8 "2 X 1¼ 63.5 0.5 "139.7mm X 3 88.9 1.9 " 6 X 101.6 2.6 "2 X 1½ 2.50 63.5 1.3 0.6 "139.7mm X 3.50 88.9 4.4 2.0 8 X 2 5.00 127.0 1 12.2 5.5 "2½ x 2 2.50 63.5 1.2 0.5 1 5 X /2 3.50 88.9 4.6 2.1 8 x 2½ 5.00 127.0 12.1 5.5 2.50 1.5 3.50 4.6 5.00 12.0 "76.1mm X 1½ 63.5 0.7 5 x 2 88.9 2.1 8 x 3 127.0 5.5 .76.1,m X 2 2.50 63.5 1.6 0.8 5 x 2½ 3.50 88.9 4.5 2.0 8 x 5.00 127.0 11.9 5.4 3 x 11/4 2.50 63.5 1.3 0.6 5x3 3.50 88.9 4.4 2.0 8x5 5.00 127.0 11.3 5.1 x V/ 2.50 63.5 1.3 0.6 " x 3.50 88.9 4.5 2.0 8 x 6 5.00 127.0 10.8 - 4.9 3 X 2 2.50 63.5 1.3 0.6 "1651 X 4.00 101.6 5.5 2.5 10 X 4 6.00 152.4 21.9 10.0 "3x2½ 3.00 76.2 1.5 0.7 "165.1mmX4 4.00 101.6 6.0 2.7 10x5 6.00 152.4 21.6 9.8 "3 X 76.1mm 3.00 76.2 2.0 0.9 4.00 101.6 5.6 2.5 lOx 6 6.00 152.4 21.1 9.6 4 x 1¼ 3.00 76.2 2.2 1.0 "6 x2 4.00 101.6 6.0 2.7 10 x8 6.00 152.4 19.5 8.9 4 x 1½ 3.00 76.2 2.3 1.0 6 x 2½ 4.00 101.6 6.0 2.7 12 x 7.00 177.8 28.0 11 12.7 3.00 2.3 4.00 6.0 7.00 30.0 *4 X 2 76.2 "6 X 76.1mm 101.6 2.7 12 x 6 177.8 13.6 "4 x 2½ 3.00 762 2.3 1.0 6 x 4.00 101.6 6.0 2.7 12 x 8 7.00 177.8 28.0 12.7 "4X76.lmm 3.00 76.2 3.2 1.5 *6 x 4 4.00 101.6 5.9 2.7 12x10 7.00 177.8 33.0 15.0 X 3.00 76.2 2.6 1.2 "6 X 139.7mm 4.00 101.6 6.3 2.9 Note: Sizes matted with an astetisk ) are only available In Figure 250 Cast Sizes without an asteilaic are only available in FIgure 350 Fabricated. U 07 Patented P1 e Nominal Dimensions Net O.D. Takeout Center to End Size Outlet Wt. A B C 0 Inches NPT Inches Inches Inches Inches Lbs. Inches mm mm mm mm Kg. 1/2 1.25 1.75 1.89 0.77 31.8 44.5 48.0 1 0.3 3/ 1.25 1.75 1.89 0.77 11h 1.900 48.3 31.8 44.5 48.0 0.3 1 1.37 2.00 2.02 0.88 34.8 50.8 51.3 0.4 1/2 125 1.75 1.89 0.92 31.8 44.5 48.0 0.4 3/ 1.25 1.75 1.89 0.92 2 2.375 60.3 31.8 44.5 48.0 0.4 1 1.37 2.00 2.02 1.06 34.8 50.8 51.3 0.5 1/2 1.47 1.97 1.89 1.28 37.3 50.0 48.0 0.6 3/ 1.47 1.97 1.89 1.28 2'/2 2.875 73.0 37.3 50.0 48.0 1 0.6 1 1.37 2.00 2.02 1.50 1 34.8 50.8 51.3 0.7 * ISO-i threaded outlets are available upon request Figures 391, Figure 312 Figure 313 392 and 393 221/2" Elbow 111/4 Elbow Adapter Nipples E to E Appx. Wt. C to E Appx. Wt. CtoE Appx. Wt. Nominal Inches Lbs. Inches Lbs. Inches Lbs. Size mm Kg. mm Kg. mm Kg. 11I4" 4.00 0.8 1.75 0.4 1.38 0.4 101.6 0.4 44.5 0.2 35.1 0.2 4.00 0.9 1.75 0.5 1.38 0.5 101.6 0.4 44.5 0.2 35.1 0.2 2• 4.00 1.2 1.88 0.6 1.38 0.6 101.6 0.5 47.8 0.3 35.1 0.3 2'I2" 4.00 1.9 2.00 0.7 1.50 1.1 101.6 1 0.9 50.8 1 0.3 38.1 0.5 • 4.00 2.5 2.25 1.4 1.50 1.2 101.6 1.1 57.2 0.6 38.1 0.5 • 6.00 5.5 2.63 2.4 1.75 2.2 152.4 2.5 66.8 1.1 44.5 1.0 • 6.00 7.4 2.88 4.1 2.00 3.3 152.4 3.4 73.2 1.9 50.8 1.5 6.00 9.5 3.13 5.6 2.00 4.6 61 152.4 4.3 79.5 2.5 50.8 2.1 8 • 6.00 14.2 3.88 11.1 2.00 8.7 152.4 6.4 98.6 5.0 50.8 3.9 8.00 27.0 4.38 14.0 2.13 9.1 203.2 12.2 11.3 6.4 54.1 4.1 12" 8.00 33.0 4.88 22.0 225 16.7 203.2 15.0 1 124.0 10.0 1 57.2 7.6 Figure 391 Figure 392. Figure 393 Figure 312 ME Figure 313 CtoE Figure 327 Figure 341 Cross 150 lbs. flange Adapter Nominal C to E Appx. Wt. E to E Appx. Wt. Size riches Lbs. Inches Lbs. mm kg, mm kg. 1'/4• 2.75 2.0 4.00 2.8 69.6 0.9 1 101.6 1.3 1 /2• 2.75 2.2 4.00 3.2 69.9 2.0 101.6 1.5 2• 3.25 2.7 4.0 5.2 82.6 1.2 101.6 2.4 21/? 3.75 5.0 4.00 8.0 95.3 2.3 101.6 3.6 4.25 7.1 4.00 10.2 108.0 3.2 101.6 4.6 • 5.00 11.9 6.00 17.2 127.0 5.4 152.4 7.8 5. 5.50 17.1 6.00 21.4 139.7 7.8 152.4 9.7 6 • 6.50 27.5 6.00 26.0 165.1 12.5 152.4 11.8 8 • 7.75 47.0 6.00 38.4 196.9 21.3 152.4 17.4 10• 9.00 68.0 8.00 65.0 228.6 30.8 203.2 29.5 12• 10.00 107.0 8.00 91.0 254.0 48.5 203.2 41.3 LiiI •ii1 I I EtoE i I ; I Figure 341 E Figure 327 CthE LIP Page 5 of 6 TFPIB1O Figures 391, 392, 393; 312 and 313 Figures 327 and 341 Page 6 of 6 TFP181O Figure 321 ..- CtoE-.1 1CIOE Figure 321 Figure 321 Reducing Tee Nominal C to E Appx. Wt. Nominal C to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Inches mm Kg. Inches mm Kg. 1½ x 1½ , 3.25 82.6 2.0 0.9 6 x 6 x 4 6.50 165.1 26.6 12.1 2x2x11h 3.25 82.6 2.7 1.2 6x6x5 6.50 165.1 27.0 12.2 21,4 x 21h x 1/4 3.75 95.3 42 1.9 8 x 8 x 2 196.9 7.75 36.2 16.4 21h x 21h x ½ 3.75 95.3 4.2 8 1.9 x 8 x 3 7.75 196.9 36.5 16.6 2½ x 2½ x 2 3.75 95.3 4.3 8 2.0 x 8 x 4 196.9 7.75 36.6 16.6 3x3x11h 4.25 108.0 5.3 2.4 8x8x5 7.75 196.9 36.8 16.7 3 x 3 x 2 4.25 108.0 5.5 2.5 8x8x6 7.75 196.9 37.0 16.8 3 x 3 x 2½ 425 108.0 5.8 2.6 lOx lOx 2 9.00 228.6 57.1 25.9 4x4x1¼ 5.00 127.0 9.8 4.4 10x10x3 9.00 228.6 57.4 26.0 4x4x1½ 5.00 127.0 9.9 4.5 10x 10x4 9.00 228.6 57.6 26.1 4x4x2 5.00 127.0 10.1 4.6 10x10x5 9.00 228.6 57.8 26.2 4x4x2½ 5.00 127.0 10.3 4.7 - 10x10x6 9.00 228.6 58.0 26.3 4x4x3 5.00 127.0 10.5 4.8 10x10x8 9.00 228.6 58.4 26.5 5x5x2 5.50 14.5 12x12x3 10.00 80.2 139.7 6.6 254.0 36.4 5x5x2½ 5.50 14.8 12x12x4 10.00 80.5 139.7 6.7 254.0 36.5 5x5x3 5.50 15.2 12x12x5 10.00 80.7 139.7 6.9 254.0 36.6 5x5x4 5.50 15.8 12x12x6 10.00 80.9 139.7 7.2 254.0 36.7 6x6x2 6.50 26.5 12x12x8 10.00 91A 165.1 11.9 254.0 41.5 6x6x2½ 6.50 26.5 12x12x10 10.00 91.8 165.1 12.0 254.0 41.6 6x6x3 6.50 26.5 165.1 1 12.0 General Notes: It is the Designers responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and perfomiance data is not exceeded. Always read and understand the installation instructions 9001 (11-1-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. tqCa Fire & Build/hg IlProducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 707 Flexible Coupling LY General Description a90 ;i See FureProtection ' Submittal Sheet for Pressure Rating and. Listing/Approval Information The Figure 707 Flexible Coupling is capable of pressures up to 500 psig (3447 kPa) depending on pipe size and wall thickness when used in fire protection services. It provides a dependable method of joining pipe and is suitable for use in a variety of applications. Rigid Couplings are recommended for dry pipe and freezer applications. WARNING The Figure 70717exible Coupling described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any otherauthoritieshavingjutisdiction. Failure todo so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturer should be contacted with any questions. Technical Data Figure: 707 Sizes: 1W - 12 Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing / Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Non-lead orange paint Are brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade "A" EPDMA, Prelubricated (Grade "A" EPDMA) or Grade "E" EPDM Td-Seal, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicablestandards of theNationaJ Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractoror product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid forand properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwithlyco Are Products orfor products and components which have been subject to misuse, improperinstallation,corrosion,orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/orthestandardsof any otherAuthodtiesHaving Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Are Products neither assumes, nor authorizes any person to assumeforit,anyotherobligationinconnectionwith the sale of products or pails of products. Tyco Fire Productsshalinotberesponsibleforsprinklersystem designenDrsorinaccurateorincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CCNSEQUEN11ALDAMAS,INCLUDINGBLJrNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHEIHERTYCOFIREPRODUCTSWASINFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALLTYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. IMPLIED, INCLUDING WARRANTIES OF MERCN4NTABILITY AND FITNESS FOR A PAR7K1ARP(V, Boll/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Mm. Tensile =Warranty 110,000 psi/758,422 kPa) Metric - conforming to ASTM F568M Gasket (specify when ordering) Grade "A" EPDMA violet color code ambientto+150°F(+66°C)forfire protection systems. Not recommended for hot water systems. Tri-seal (Grade "E"EPDM), green colorcode. Prelubricated (Grade "A" EPDMA) (See Data Sheet 1FP1895 for aid in selecting proper gasket) Page 1 of 2 July 2004 TFPI840 Page 2 of 2 TFP1S4O Figure 707 Grooved Coupling Pipe Max. End Gap Max.t Pressure Max.t End Load Nominal Dimensions Deflectiont Bolt Size * Net Wt. O.D. A B C "Per Inches! Size Inches Inches psi Lbs. Inches Inches Inches Couplin g Foot Dia. x Lg. Lbs. MM mm kPa N mm mm mm mm/rn Kg. 1.900 0.13 500 1,418 2.97 4.63 1.81 0.79 '/2°X3" 2.5 2 48.3 3.3 3,447 6,308 754 117.6 460 - • 65.8 M12x 76 1.1 2.375 0.13 500 2,215 3.54 5.25 1.88 , 0.63 /2" x 3" 3.0 2 60.3 3.3 3,447 9,853 899 133.4 47.8 3 - 1 52.5 M12x 76 1.4 2.875 0.13 500 3,246 4.06 5.75 1.88 0.52 '/2" x3" 3.5 2" 2 73.0 3.3 3,447 14,439 103.1 146.1 47.8 2° -2g 43.3 M12x76 16 3.000 0.13 300 2,121 4.19 5.75 1.88 0.50 3.7 76.1 76.1 3.3 2,068 9,435 106.4 146.1 47.8 2° -23 417 M12 x 76 1.7 3.500 0.13 500 4,811 4.69 6.38 1.88 0.43 /2" x3' 4.0 30 88.9 3.3 3,447 21,400 119.1 162.1 47.8 20 35.8 M12x 76 1.8 4.500 0.25 500 7,952 5.95 8.25 2.06 , 0.67 /e" x 31/" 7.0 4ff 114.3 6.4 3,447 35,372 151.1 209.6 52.3 55.8 M16x83 3.2 5.563 0.25 500 12,153 7.08 10.00 2.06 0.54 3/4" x 4W 10.5 5. 141.3 6.4 3,447 54,059 1798 254.0 52.3 2 35 45.0 M20x 121 4.8 6.500 0.25 300 9,955 8.19 11.25 2.06 2 - 12• 0.46 12.5 16 5.1 165.1 6.4 2,068 44,282 2080 285.8 523 38.3 M20 x 121 5.7 6.625 0.25 500 17,236 8.30 11.25 2.06 20 -0 1 • 0.45 W x 43/411 12.5 6" 168.3 6.4 3,447 76,670 2108 285.8 52.3 37.5 M20 x 121 57 8.625 025 500 29,213 10.68 14.00 2.47 0.35 /8" x 61/2 23.5 8" 219.1 6.4 3,447 129,946 271.3 355.6 62.7 10 -40 29.2 M22 x 165 10.7 10.750 025 500 45,381 13.06 16.44 2.63 , 028 1" X6V2" 33.0 100 273.0 6.4 3,447 201,864 331.7 417.6 66.8 1 -20 23.3 M24 x 165 150 12.750 025 500 63,838 15.39 18.84 2.63 , 023 1"x61/2" 37.0 12° 1 7 323.9 6.4 3,447 283,966 3909 478.5 66.8 19.2 M24 x 165 16.8 * Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based o n s t a n d a r d w e i g h t s t e e l p i p e . P r e s s u r e r a t i n g s a n d e n d l o a d s m a y differ on other pipe materials and/or wall thickness. Contact Tyco Ar e P r o d u c t s f o r d e t a i l s . S e e F i r e P r o t e c t i o n E q u i p m e n t Submittal Sheet for Listing and Approval pressure ratings. ** Gold color coded metric bolt sizes are available upon request f Max End Gap and Deflection is for cut grooved standard weight pipe. V a l u e s f o r r o l l g r o o v e d p i p e w i l l b e ½ t h a t o f c u t g r o o v e d . General Notes: It is the Designers responsibility to select products s u i t a b l e f o r t h e i n t e n d e d s e r v i c e a n d t o e n s u r e ISO that pressure ratings and performance data is not exceeded. Alway s r e a d a n d u n d e r s t a n d t h e i n s t a l l a t i o n 9001 instructions (II-1-1000). Never remove any piping component or correct o r m o d i f y a n y p i p i n g d e f i c i e n c i e s w i t h o u t first depressurizing and draining the system. Material and gasket selecti o n s h o u l d b e v e r i f i e d t o b e c o m p a t i b l e for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylva n i a 1 9 9 4 6 Description Submittal Sheet for Pressure Rating and Listing/Approval Information tqCV Fire & 8u11d1n9 IlProducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco4ire.com Grinnell Grooved Fire Protection Products Figure 772 Rigid Coupling - Patented t.. General TheFIguie772 Rigid Coupling providesarigidjointby firmly gripping along the circumference of the pipe grooves. Rigid couplings are preferred for dry pipe and freezerappflcalions. Figure 772 Rigid Couplings are a proven dependable method of joining pipe and are an economical alternative to welding, threading or using flanges. 1t1s capable 0fpessuresupt0500psig (3447 kPa) depending on pipe size and wall thickness when used in fire protection services. The Figure 772 Rizid Coupling described herein must be installedandmaintainedin compliance with thiadocumentasllasit4ththeappficebleslendards oftheNationalFireProtectionAssoc!alion,inaddition to the standards of any other authorities having jurisdiction. Failure to do so may impair the pesformance of this device. The owner is responsible for maintaining their fire protection stem and det'ices in proper operating condition. The installing contractor or sprinkler manufactarershouklbecontaotedvAffianyquesffon& Technical Data Figure: 772 Sizes: 11/4 - 12' Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact listing / Approval Information. Page 1 of 2 Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 ASTM A-183, Zinc Plated, (Mm. Tensile = 110,000 psi/758,422 kPa) Metric - conforming to ASTM F568M Gasket (specify when ordering) Grade "A" EPDMA violet color code ambientto+1500F(+66°C)forfireprotection systems. Not recommended for hot water systems. Tri-seal (Grade 'E"EPDM), green colorcode for use in dry pipe or freezer systems. Prelubricated (Grade "A" EPDMA) (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering When placing an order, indicate the full product name. Please specifythe quantity,figure number, type of gasket, Grade "A" EPUMA, Prelubricated (Grade "A" EPDMA) orGrade"E" EPDMTri-Seal, and size. GrinnellGroovedPipingPmducts,valves,accessories and other products are available throughout the U.S., Canada, and internationally, through anetwork of distribution centers. You maywilte directly orcall 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicablestandards of theNational Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractororproduct manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited UU7 Products manufactured by Tyco Am Products am warranted solelytotheoriginal BWerterten (10) years againstdefectsinmeterialandworinanshipwhenpaid forandproperlyinstalledandmakitainedundernormal useandserv. ThiswananlywIeqireten(10)yeazs from dale of shipment by Tyco Are Products. No warranty is given for products or components bynlesnotaffihiatedbyownership wthlycoRrePmdudsorforpmductsandcompOneflts whhvebeensubjecttomisuse,irnpzoperinsfaflation, cormsion,o beeninsfalled,makitained, modilled or repaired in accordance with applicable Standards of the National Am Protection Associon PRA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Are Products to be defective shall be either repaired or replaced, at TO Are Products' sole option. Tyco Are Products neither assumes, nor authorizes any person umefurit,anytherobligationinconnectionwmth the sale of products or parts of products. TycoRie Products shall not be responsible forspfinlder system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO BIB'lT SHALL TYCO ARE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIASIUTY OR UNDElM0MLEG&TffM,FORINCIDENTk INDIREI,SPLORCONSEQUENTIALDNtfIAGES, INIJJDING BUTNOTUMIIEDTO LABOR cHAFGES, REGARDLESS 0FWHEIHER1'vtORREPRODUCTS WAS INFORMEDABOIJrThEPOSSIBIUTYOFSUCH DAMAGES, AND IN NO RW SHALL TYCO ARE PRODUCTS' LIABIUWEXCEE)ANAMOIJNtEQUPL 1O THE SALES PRICE jig Rigid Couplingsarererommendedfordrypipeand Procedure freezer applications. Bolt/Nuts: Track Head Bolts - conforming to M.viiIu July 2004 i'FPlaSO I Page 2 of 2 TFP185O Figure 772 Grooved Coupling Pipe Max."* End Gap Max.f Pressure Max.t End Load Nominal Dimensions Bolt Size** Net Wt. O.D. A B C Size Inches Inches psi Lbs. Inches Inches Inches Dia x Lg. Lbs. mm mm kPa N mm mm mm 1.660 0.06 300 649 2.75 4.38 1.81 %"X2Y4" 1.0 424 1.5 2,068 2,887 699 111.3 46.0 M10x57 0.5 1½" 1.900 0.08 500 1,417 3.00 4.62 1.81 Wx21/4' 1.0 48.3 2.0 3,447 6,303 76.2 1173 46.0 M10x57 0.5 2" 2.375 0.13 500 2,214 3.41 5.12 1.88 %'X2Y4" 1.5 60.3 3.3 3,447 9,848 86.6 130.0 47.8 M10x57 0.7 21h" 2.875 0.13 500 3,244 3.91 1 5.63 1.88 %"xVAN 2.5 73.0 3.3 3,447 14,430 99.3 1 143.0 47.8 M10x57 1.1 76.1mm 3.000 0.13 300 2,120 4.19 5.72 2.00 M10x57 2.6 76.1 3.3 2,068 9,430 106.4 1453 50.8 1.2 3.500 0.13 500 4,808 4.63 6.25 1.88 %"X2Y4" 2.6 88.9 3.3 3,447 21,387 117.6 158.8 47.8 M10x57 1.2 4.500 0.19 500 7,948 5.81 750 1.97 %" x 21/4" 3.5 114.3 4.8 3,447 35,353 147.6 190.5 50.0 M10x57 1.6 139.7mm 5.500 0.19 300 7,127 7.02 9.72 2.06 M16 x 83 7.5 139.7 4.8 2,068 31,701 178.3 2469 52.3 3.4 50 5.563 0.19 300 7,288 7.09 9.71 2.04 %" x 3W 7.5 141.3 4.8 2,068 32,417 180.1 246.6 51.8 M16x83 3.4 165.1 6.500 0.19 300 9,950 8.09 10.53 2.13 M16 x 83 7.6 165.1 4.8 2,068 44,258 205.5 267.5 54.1 3.4 - 6- 6.625 0.19 400 13,782 8.09 10.53 2.13 %" x 31/40 7.6 168.3 4.8 2,758 61,302 205.5 267.5 54.1 M16x83 3.4 8" 8.625 0.19 450 26,278 10.56 13.56 2.62 3/40 x 43/40 18.0 219.1 4.8 3,103 116,885 268.2 344.4 66.5 M20 x 121 8.2 10" 10. 750 0.13 250 22,679 12.84 16.41 2.62 1" X 61/20 24.6 273.0 3.3 1,724 100,876 326.1 416.8 66.5 M24 x 165 11.2 12" 12.750 1 323-913.3 0.13 250 31,903 1 15.41 18.84 2.62 1"x61h" 42.0 1,724 141,905 391.41478-5. 66.5 M24 x 165 19.1 Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weig h t s t e e l p i p e . P r e s s u r e r a t i n g s and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco F i r e P r o d u c t s f o r d e t a i l s . See Fire Protection Equipment Submittal Sheet for Listing and Approval pressu r e r a t i n g s . Gold color coded metric bolt sizes are available upon request. 1 Max End Gap is for cut grooved standard weight pipe. Values for roll grooved pipe wi l l b e ½ t h a t o f c u t g r o o v e d . Figure 772 Rigid Couplings have an Anti-Rotation Feature of "gripping teeth" along the c o u p l i n g k e y s i n s i z e s 11/4' -4", which make the Figure 772 perfectly suited for "arm over" installations where the likelihood of rot a t i o n i s g r e a t e s t . T h i s f e a t u r e m a y e l i m i n a t e t h e n e e d o f extra hangers to support the arm over due to increased rigidity and gripping for c e s a v i n g t i m e a n d c o s t . General Notes: It Is the Designer's responsibility to select products suitable for t h e i n t e n d e d s e r v i c e a n d t o e n s u r e ISO that pressure ratings and performance data is not exceeded. Always read and u n d e r s t a n d t h e i n s t a l l a t i o n 9001 instructions (I1-1-1000). Never remove any piping component or corrector modify a n y p i p i n g d e f i c i e n c i e s w i t h o u t first depressurizing and draining the system. Material and gasket selection should be v e r i f i e d t o b e c o m p a t i b l e for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19 9 4 6 Printed U.S.A. t11CG /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 BlazeMaster ® CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Tyco Fire and Building (TFBP) Blaze- Master CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially devel- oped thermoplastic compound com- posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, In addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Ange- les. (Refer to IH-1900, Rev. 0, January 2005 installation instruction & Techni- cal Handbook" for exact listing/ap- proval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange BlazeMaslert is a registered trademark of Noveon IP Holding Corp. Paae I of 6 Page 2 of 6 TFPI9I5 NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT Ft OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. Ibsflt. IbsJft. PER LIFT lbs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1418 1.315" 1.101' 0.26 0.67 5040 1320 1-1/4" 1.660 1.394" 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1186 2.375" 2.003" 0.84 2.20 1260 1063 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3.500 2.952" 1.87 483 720 1344 FIGURE 1—PIPE DIMENSIONS Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- ance with I1-1-1900, Rev. 0, January 2005 "Installation Instruction & Techni- cal Handbook'". Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire. protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFPI9I5 Page 3of6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT $ CHD WEIGHT TYPE NUMBER (I/O) (lb.) TEE 80000 3/4• FA. 40 0.11 1/0 80001 1 11/16 40 0.19 I 80002 80003 1-1/4 1-1/2 7/8 1-11W 40 80 0.26 0.51 Th ___ 80004 2 1-3/8 80 0.90 80005 2-1/2 1-9/16'80 1.59 T/O 1/0 80006 3 1-13/16 80 2.41 XxYxZ X Y Z 3141 x 3t4'x V 3/4 3/4 5/8" 80132 40 0.14 80133 1"x3/4"x3/4" 9/16" 9/16" 3/4" 40 0.14 80134 x 3/4" x 3/4" 11I16 3/4" 40 0.17 80260 1"x?x3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4x1"x3/4" 5/8 5/8" 15116" 40 021 80136 1-1/4"x Vx V 3/4" 3/4" 15/16 40 0.22 80137 1-1/4"x1"x1-1/4" 15/16" 15/16" 7/8" 40 026 REDUCING TEE 80261 1-1/4" x 1-1/4" x 2/4" 5/8" 5/8" 7/8" 40 0.23 80262 1-1/4"x1-1/4xV 314• 3/4" 71W 40 026 80138 1-1/4"xl-1/4x1-112" V 1" 1" 80 0.43 1/0 80140 1.1/2"x1-1/4"x3/4" 9/16" 9/16 1" 80 0.36 80141 1-1/2"x1-1/4"x? 9/16" 9/16" 1.1/16" 80 0.38 80263 80264 1-1/2" x 1-1/2" x 3/4" 1-1/2"xl-1/2"xl" 9/16" 9116" 9/16" 9116" 1" 1-1/16" 80 80 0.36 0.38 X Ln VI 80275 1-lIZ" x 1.1/2" x 1-1/4" 7/8" 7/8" 1 80 0.45 T/O 80265 x 2" x 3/4" 3/4" 3/4" 1-318" 80 0.61 Page 4 of 6 TFPI9I5 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHO. WEIGHT TYPE NUMBER (170) (lb.) 45 ELBOW 80050 3/4 318 40 0.08 80051 1 3/8 40 0.11 80052 1-114 3/4 40 0.20 80053 1.1/2 T/0, 112 80 0.31 80054 2 314 80 0.56 80055 2.1/2 13/16 80 0.89 80056 3 80 1.19 80075 3/4 1/8 40 0.07 COUPUNO & 80076 1. 118 40 0.11 REDUCING COUPLING 80077 1-1/4 3/16 40 0.12 80078 1-112 3/16 80 0.25 80079 2 3/16 80 0.38 IFT/O 80080 2-1I2 1/4 80 0.67 80081 3 3/16 80 0.91 80220 rx3/4 118 40 0.08 80200 ? x 3/4 7116 40 0.04 80201 1-114x314 . Ir2l 40 0.11 80202 1-1/,r x V 5/W 40 0.12 80203 1-1/2x34 5/8 80 0.16 80204 1-112x1 80 0.14 REDUCER BUSHING 80205 1-1/2x1-1/4 3/8 80 0.17 80206 2 x 3/4 13/16 80 0.27 80207 2"x V 11/16 80 026 TFPI9I5 Page 5of6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT HD WEIGHT TYPE NUMBER sO) C / (lb.) SPRINKLER HEAD ADAPTER 0175E 3/4 x 1PZNPT 7/16 80 0.20 0176E rx 1/2 NPT 7116 80 022 1;T/0 80175WL 3/4 x 112 NPT 7/16 40 0.16 80179 1x3/4NPT 13f16 40 0.43 SPRINKLER HEAD ADAPTER 80175W 3/4x1I2NPT 1/2 40 0.19 q; T10 80176W 1"x 1/2 NPT 12 40 0.18 SPRINKLER HEAD ADAPTER (SPIGOT) 80177L 3/4x1/2NPT 1/2 40 0.16 80178 V x 1/2 NPT smill 40 0.20 4-4vo 80180 1 x 3/4' NPT 7/8' 40 0.40 FEMALE ADAPTER r 80142 3/4'x 3/4' NPT 13/16' 0.4180 40 m M VxVNPT 7/8' 40 0.63 80146 1-1/4'x1-1/4NPT 1-1/8' 40 1.03 Page 6 of 6 TFPI 915 l 80199 3/4'xl/2'NPT 9/16' V 40 0.20 80189 1' x 1/2' PIPT 3/4' 1.1/4' 40 0.26 _____ X T/O 80196 1'x314'NPT 1-1/16' 1-7/16' 40 0.28 FIGURE 2— F17TING DIMENSIONS (Part 4 of 4) Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. TYCO FIRE PRODUCTS. 451 North Csannnn A I-a1-fl tLICO Flo w / Tyco Fire lControl I Products ARE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET TYCO ARE PRODUCTS 451 North Cannon Avenue Lansdale, Pennsylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TEL: (800) 381-9312 FAX: (800) 791-5500 E-i,,.. techserv@tycofp.com .. Introduction Tyco Fire Products (TFP) BlazeMasters CPVC pipe and fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at Technical Data the same time, they provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. Sizes: 3/411_31 Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM, CUL, NSF, Dade County, LPCBI Pipe: ASTM F442, SDR 13.5 MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and Note: See curmntTFP BlazeMaster Installation Insiniclions and ASTM F439 (Sch. 80) Technical Manual, for exact llsting(appioval infoimation Colon Orange Pipe Nom.Plpe Size Avg. O.D. Inches Avg. I.D. Inches WI. LbsJFt. Wt. ILO filled Pipe thsjFt. R. of Pipe per Lift WL per Uft Lbs. 3/U 1.050 0.874 0.17 0.43 7875 1413 in 1.315 1.101 0.26 0.67 5040 1320 1114, 1.660 1.394 0.42 1.07 2835 1191 1720 1.900 1.598 0.55 1.40 2205 1136 21 2.375 2.003 0.86 1 2.20 1 1260 1063 21/2- 2.875 2.423 1.26 3.22 1215 1531 3" 3.500 2.952 1.87 1 4.79 720 1344 Fittings TO 450 Elbow Reducing 900 Elbow 900 Elbow Part No. Size Sch. T/O I Wt. 80050 3/Il 40 3/1 0.08 lb. 80051 1" 40 /e" 0.11 lb. 80052 11/411 40 3/411 0.20 lb. 80053 1 11/21 80 1 71.' 0.31 lb. 80054 2 80 3/4" 0.56 lb. 80055 2¼" 80 3/4U 0.89 lb. 80056 3" 80 1" 1.19 lb. IPart No. Size I lSch. I I Tb t I. Ilb.l Ii i I 2 180032 Ii" x/4"l 40 I 1I/U /ie" 10.161 Part No. Size Sch. TO I Wt. 80025 3/I 40 9/is" 0.09 lb. 80026 40 3/0 0.14 lb. 80027 11/4" 40 7411 0.21 lb. 80028 1W' 1 80 iVie" 0.40 lb. 80029 80 11/4" 0.79 lb. 80030 21h" 80 11/2" 1.14 lb. 1 80031 311 80 113/ie" 1.82 1b. Tee Reducing Cross Cross Part No. Size Sch. T/O Wt. 80000 3/41 40 5/i" 0.11 lb. 80001 111 40 80002 1 74" 7/EU 80003 40 1¼" 80 1" WE26 80004 80 1/e" 80005 21/2" 80 19/is" 1.59 lb. 80006 80 1"/ie" 2.41 lb. IPart 1No. i I Size I I Sch. I I 1/0 Wt. I I llb.l 1112 180015 Ii" XI4"I 40]14- I1V1s1 10.281 Part No. Size Sch. T/O Wt. 80009 3/411 40 /Ie" 0.13 lb. 80010 10 40 /" 023 lb. 80011 1'/4" 40 l5/,U 0.34 lb. 80012 1 11/2" 80 1 1'/ie" 0.67 lb. 80013 80 1/e" 1.00 lb. 80014 1 21/2" 80 19/is" 1.91 lb. 80008 80 P3/te" 2.89 lb. 1 Tb0 Reducer - -. Bushing Part No. Size ISch. TIO I Wt. 80200 1' X 3/U 40 Vie" 0.04 lb. 80201 11/40 X314" 40 '/ie' 0.11 lb. 80202 11/4' x 1" 40 5/is" 0.12 lb. 80203 1'/2"X 3/4" 80 %" 0.16 lb. 80204 11/2" X 1" 80 Va" 0.14 lb. 80205 11/2" x 11/4M 80 3/s" 0.17 lb. 80206 2" x 3/" 80 3/4k 0.27 lb. 80207 2" x 1' 80 "lie" 0.26 lb. 80208 2" x 11/4" 80 C/ia" 0.24 lb. 80209 x 11/2" 80 'lie" 10.19 lb. 80215 21/2" x 1" 80 1/ie" 0.42 lb. 80214 21/2' X V/c" 80 V/i" 0.45 lb. 80213 21/2" x P/a" 80 1/." 0.46 lb. 80211 21h" x 2" 80 1/,." 0.29 lb. 80210 3"x 2' I 80 2/ue" 0.72 lb. 80212 x 21/2" 80 1/,e 0.47 lb. I. Reducing -i Tb' Tee TaO' TO. iTIO Coupling fEF Cap Part No Size Sch. 1/0 WI. 80100 3/" 40she" 0.04 lb. 80101 1" 40 3/s" 0.06 lb. 80102 1114" 40 Va" 0.10 lb. 80103 11/2' 1 80 le" 0.20 lb. 80 5/s" 0.31 lb. 80104±3~' 80105 80 'I." 0.58 lb. 80106 80 Is 0.88 lb. 170 Grooved Coupling - -- Pipjo.D. Adapter Part No. Size Sch. 1/0 WI. Pipe OD 80160 11/4" x 11/40 Grooved 40 2 /ie" 0.78 lb. 1 i/II (1.660") 80161 11/2" x Via' Grooved 80 2 '/is' 0.95 lb. We (1.900') 80162 2" x 2" Grooved 80 2 /ie" 1.42 lb. 2'(2375') 80163 2'Ia" x 2/2" Grooved 80 2 /e" 2.28 lb. 2¼" (2.875') 80164 3' x 3" Grooved 80 21/41 3.00 lb. 3" (3.500") 80168 3" x 76.1 mm Grooved 80 2¼" 2.72 lb. 76.1 mm (3.000") Part No Size Sch. 1/0 Wt. 80075 Y-N 40 '/." 0.07 lb. 80076 In 401 Va' 0.11 lb. 80077 1114" 40 /ie' 0.12 lb. 80078 17? 80 3/is" 0.25 lb. 80079 80 /ie" 0.38 lb. 80080 21/21 80 lie" 0.67 lb. 80081 1 80 /,e" 0.91 lb. 170 Female -.- Adapter Part No. Size Sch. 1/0 M. 80142 3/40 x 3/" NPTM-/-NOlb.80145 x 1" NPT b.80146 114w x 11141NP lb.80147 1¼" x 1Va' NP lb.80148 x 2" NPT lb. TO Male Adapter Part No. Size I Sch. 110 I Wt. 80157 3/41 x /" NPT 40 1 1./,e" 0.33 lb. 80158 1" x In NPT 40 1 13/0 1 0.56 lb. TIO Reducing Coupling t:Ld I PadNo.1 Size ISch.1 TIO Wt. 80220 11" x3/.N 40 1 'Ia" 0.08 lb. Part No. Size Sch. 1/0 Wt. lb. - 1 2 1 - 3 80132 3/4'X 3/4'x 1" 40 3.6" 6" 5/1 0.14 80133 1"X 3/4'X3/4" 40 ¼" "/ie" W 0.14 80134 1" X3 /4" x 1" 40 W W l4" 0.17 80260 1" x 1" x 3/I 40 3/4w 3/" /ie 0.16 80135 1¼" x 1" x 3/" 40 " tie 3 14 lie" 0.21 80136 V/c" xl" x 1" 40 11/1 0 3/4" '5/ie" 0.22 80137 11/41 x 1" x 11/4" 40 Wee" /a" /,e" 0.26 80261 11/4"x 11/4" x /" 40 %" /e" '/a" 0.23 80262 1114" x 11140 x 1" 40 3/" 3/" 7/U 0.26 1 80138 1'/4" x 11/4" X 11/2" 80 IN 1" Is 043 80140 11/2" x 11/4" x /" 80 1/2" shm iN 0.36 80141 11/20 X11/40 X1" 80 Va" 5/s" lYe' 0.38 80263 1¼" x 11/20 X 3/41 80 s/ia" -p ito7 1" 1 0.36 80264 11/28 X 1¼" xl" 80 -/,.a Oheo 1" 0.38 80275 11/2' x 1'/a" X 11/4" 80 7/i" 7/e1 lii 0.45 80265 1 20 x2'x314" _!_ 21 80266 2' x 2" x 1' 80 la" 'I." 1%" 0.66 802741 2" x 2" x 11/4" 80 In 1" 1/." 0.74 802671 2" x 2"x P/a" 80 lYe" V/a" 1/." 10.78 80271 21/2" x 2/2" x 1" 80 1"/te' 1"/,e"' 1°lie" 1.43 80272 21/2'x 21/2" X V/i" 80 1"/ie" 1"/ie" V/ia" 1.46 80273 21/2" X 21l? X V/a" 80 1"/te' 111/ta" 19/16" 1.48 80276 21/a" x 21/2" x 2" 80 1"/a" III/is" V/ia" 1.50 80270 3" x Tx V/a" 80 V/i" 1/4" 11 3/i." 228 80268 3" x 3" x 2" 80 1/4" 1/e" 13/4" 2.25 80269 3" x 3"x 21/2' 80 1/4" P/c" 1'/,e" 2.44 Part No. Size Sch. 110 Wt. I 80175E I4 X 1/21 NPT 80 7b.' 0.20 lb. I 80176E 1" x Va" NPT 80 7/e1 0.22 lb. f80177WL /i x 'k' NPT 40 /.' 0.16 lb. E80179 1 x NPT 40 2/4' 0.43 lb. Sprinkler Head Adapter (Spigot) with Brass Threaded Insert Part No. Size Sch. 80175W 3/4' x 'Ia" NPT I I 40 7/1" 1 0.19 lb. 80176W 1" x 'Ia" NPT 40 1/a" 1 0.18 lb. Back-to-Back Cross with Brass Threaded Insert ' TI Sprinkler Head Adapter with Brass Threaded Insert Et Sprinkler Head Adapter with Brass Threaded Insert Part No. Size Sch. TIO Wt. 80177L I Ia" X 1/2" NPT 40 Va" 0.16 lb. 80178 lox /2" NPT 40 1/2" 0.20 lb. I Part I No.1 l Size I I Sch. i I I TIO Iwt. lb. I 0.471 1 1 1 21 I 80462 1' x 1" x 121 NPT X /2" NPT 40 /" 1 'Ia' 0.46 I_80463 1" x 1" x V2" NPT x 'ía " NPT I 40 I 5/I U 15/, Sprinkler Head Adapter 900 Elbow with Brass Threaded Insert Back-to-Back Tee with Brass Threaded Insert I Part I No. No. 1 I Size Si I I Sch. ch. i I T/0 Wt. lb. I I 1 I 2 1 I 80199 I Ia" x 1h" NPT I 40 I i' I Isheo 0.20 I I 80189 i' x 'I? NPT I 40 13/,0 1/u' 0.26 I Part No. Size Sch. T/0 Wt lb. 1 2 80459 X'Ia'NPT 0.48 80460 _1"X '/2"NPT _1"X'/2" NPT X'/a'NPT _40 _40 _1'/ie" _"/e" _1'/." 0.46 Part No. Size - Sch. 1/0 Wt. lb. 2 3 80250 3/41x 1148 x /a NPT 40 "Ia' 5/SI 1" 0.22 80251 x1' x 'Ia' NPT 40 "1,.' /e" '/ie" 029 80249 1"x1"x1'NPT 40 'shs* '/,e' V/i." 0.73 802561 11l." x 1 X '/2"NPT 40 7," '1.' 1'I.' 0.30 80252 1I4_X _V14'X'Ia'NPT 40. 7I e' 1/el VI." 0.31 80257 11/20 x 11140 x Ile NPT 80 /t.' a,,. 1/,.' 0.43 80254 1'/a"x 1'/a"X1/NPT 80 'lie" 'lie" 11/.' 0.46 80258 x1'/a"x'/2'NPT 80 /a 'I.' 1'/,' 0.56 80253 2"X 2_X 1120 NPT 80 'Ia" 'Ia" 15I." 0.62 Sprinkler Head Adapter Tee with Brass Threaded Insert I gum MIMI ill limited Warranty Products manufactured by Tyco Fire Products are w a r r a n t e d solely to the original Buyer for ten (10) years against defects In material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty Is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse. improper installation, corrosion, or which have not been Installed, maintained, modified or repaired In accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective skull be either repa i r e d o r r e p l a c e d . a t T y c o F i r e P r o d u c t s s o l e option. Tyco Fire Products neither assumes, nor authorizes any person to assume for It, any other obligation In connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or Incomplete Information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONT R A C T , T O R T , S T R I C T L I A B I L I T Y OR UNDER ANY OTHER LEGAL THEORY. FOR INCIDENTAL INDIRECT. SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING B U T N O T LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIE U O F A N Y A N D A L L O T H E R W A R R A N T I E S E X P R E S S O R I M P L I E D , INCLUDING WARRANTIES OF MERCHANTABILITY AND FI T N E S S F O R A P A R T I C U L A R P U R P O S E . tqcu/iow control/ Tyco Fire 7 Dimensions -Weights Approx. A B C wt. 3/4 3'/a 2 .180 1 3/a 21!. .210 11/4 35/s 2/. .225 112 41/6 2'/2 .310 2 4'/2 2/4 .340 HAMGAFPUCATION KANGI&RESIRAINT APPLICATION It ; Fig. 28 "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range —W through 2" Material - Carbon Steel, Pre-Galvanized Function - Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for w o o d blocking. Features: Flared edge design protects CPVC pipe from any rough or abrasive surfaces. Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. The "Stand-Off" design eliminates the need for wood block extension. Can be installed on horizontal or vertical piping regardless of mounting sur- face orientation. Attached easily to wood structure with two hex head self-threading screws furnished with product. Installs easily using rechargeable electrical driver with 5116" extension socke t eliminating impact tool damage to pipe. U.L. Listed as a hanger and a restrainer for fire sprinkler piping. Approvals - Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. Meets and exceeds the requirements o f NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirem e n t w h e r e needed. UL Listed as a hanger and vertical restraint when installed on 3/8" c o m p o s i t e wood material. Use two Fig. 27B Speed Nuts when used as a hanger and r e s t r a i n t . Use one Fig. 27B Speed Nut on the upper installed screw when used as a han g e r o n l y . Order by - Figure number and pipe size. US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. OFFICEIMANUFACTURING FACILITY • 1315 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • SM 7ffi c, & >1 Fig. 22 - Hanger for CPVC Plastic Pipe Single Fastener Strap Type Size Range - 3/4" thru 2" CPVC pipe Material - Carbon Steel, Pre-Galvanized Function - Intended to perform as a hanger to support only CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. For this type of installation, use the TOLCOTm Fig. 23, Double Fastener Strap for CPVC Piping. Fig. 22, when inverted, with the hanger tab downward, can function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13,1311 and 13D. Features - Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design* pro- tects CPVC pipe from any rough surface. It is easily attached to the building structure using the s p e c i a l U L L i s t e d h e x head self threading screw furnished with the product, this is the minimum size fastener acceptable. It is rec o m m e n d e d that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No im p a c t t o o l s (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has bee n k n o w t o r e s u l t from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Note - Fastener into light gauge metal may be ordered separately. Minimum acceptable: #10 x 1" Harde n e d S e l f Threading Screw with 5116" hex washer head. Order By - Figure number and CPVC pipe size. * Patent Pending Dimensions 'Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt.I100 3/4 2/ 1/16 1 /16 5/ 5/16 9 I 2"! 17/16 1I1e 6 5/16 9 11I4 The 1°/s 13/I0 61h 5/16 11 1/2 31I 13/4 13/16 7 5/16 12 2 35/4 2V5 13/ 8 5/16 15 OfficelManulaciwlng Facility .1315 Sançsm Ave. • Corona, CA 92819 • Ph. 909.131.5599 • Fax 909.137.0330 _Customer SeMce • 800.1865256 Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type Size Range - 3/4" thru 2" CPVC pipe Material - Carbon Steel, Pre-Galvanized Function - Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 23 can also be installed on the side of a beam. The Fig. 23 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features - Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design' protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allow- ing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws' furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installa- tion tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and pipe size * Patent Pending "Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions 'Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size W000 3/4 314 19/I6 1/I6 51/2 5/16 9 I 3I8 I/ie 6 5/16 9 11/4 43/ 1/ 61I 5/16 11 1 /2 4I16 2I 1/1 7 5/16 12 2 4I 8 5/16 15 OfficelManufacturing Facility .1375 Sampson Ave. • Corona. CA 92879 • Ph: 909.731.5599 • Fax: 909.737.0330 Customer Seivice • 800.186.5266 Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount Size Range - 3/4" thru 2" CPVC pipe Material - Carbon Steel, Pre-Galvanized Function - Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13,13R and 13D. Features - Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and pipe size * Patent Pending -- Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size W000 3/4 2I 1/ I'l'. 51/2 5/16 9 I 2% 15/16 13/te 6 5/16 9 1 /4 3 11I2 61/ 5/16 11 112 3114 1/. 7 5/16 12 2 31 / - - 1 V/32 1/1 8 5/16 15 D Main 011lc&Manulacluring Facility .1375 Sampson Ave. • Corona. CA 92879 • Ph: 909.131.5599 • Fax: 909.137.0330 Customer Service • 800.186.5266 Fig. 4 - Standard Pipe Clamp Fig. 4F - Standard Pipe Clamp Felt Lined Fig. 4PVC - Standard Pipe Clamp PVC Coated Size Range — (Fig. 4) Size 1/2" thru 30" pipe. Size Range — (Fig. 4F) Size 1/2" thru 2112" copper tubing Material — Carbon Steel Function — Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shields. (Use Fig. 330 Weldless Eye Nut, Fig. 102 Eye Rod or .Fig. 101 Welded Eye Rod.) Also recommended for attachment of sway bracing up to 3'/2" pipe size, for larger pipe sizes use Fig. 4A. Fig. 4F and Fig. 4PVC are designed to reduce noise and vibration and/or prevent electrolysis. Approvals — Underwriters' Laboratories Listed in the USA (UL), Canada (cUL) 314" - 8", and approved by Factory Mutual Engineering, 3/4" - 8". Federal Specification WW-H-171 E, Type 4, 11/2" thru 24" and Manufacturers Standardization Society SP-69, Type 4. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Note — When the Fig. 4 is used as a sway brace, to ensure performance, the UL Listing requires that it must be used 7 with other TOLCOThI brace products. Maximum Temperature — 750°F / Finish — Plain 1-1g. 4 Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. 'N Order By — Figure number, pipe size and finish. Fig. 4F Fig. 4PVC Order Note — When ordering Fig. 4F allow for 3/16" felt on each half of clamp. Dimensions -Weights Pipe Max. Design Load Lbs. Size A B C D For Service Temp. Approx. Bolt Size 6500 750°F WtJ100 1/2 37/i, 1/4 11!8 11!, 5/16 500 445 29 3/4 311h€ 1/4 1'I4 11/4 5/16 500 445 31 I The 1/4 114 15!16 5/16 500 445 35 114 43/1e 1/2 13/, 11!,, 5/16 500 445 40 1112 49/,, 5/16 1"!, 1/, 5/16 800 715 42 2* 50/,, 1/2 2 21/4 39 1040 930 93 21/2* 6/,6 9/16 2112 2/4 1/2 1040 930 - 126 3* 7 5/8 2/4 The 1/2 1040 930 141 3'/2 711/,, 3/8 31!, 334 1/2 1040 930 154 4 8'/ 5/8 The 311!,, 5/8 1040 930 229 5 93 /4 3/4 3/, 411!. 5/8 1040 930 261 6 11'4 3/4 4'7s 5% 3/4 1615 1440 537 8 131!,. 1 5'!. 6 -- 3/4 1615 1440 625 10 16'/2 1 7'1. 71/4 7/8 2490 2220 1378 12 18'!, 1 8'/4 81/4 7/8 2490 . 2220 1574 14 20 11!. 9 9 7/8 2490 2220 2103 16 23 11!, 10'/4 101/4 7/8 2490 2220 2314 18 25/, 11/4 11'/2 11'/2 1 3060 2730 3276 20 28 j3/, 12'/2 12'I2 11!, 3060 2730 3863 24 331!. 1'!. 15'4 104 11/4 3060 2730 5222 30 41/, 2 19 19 1'/4 . 3500 3360 10511 fl Main OfficelMamifactwlng Facility. 1315 Sampson Ave. • Corona, CA 92879 • Ph: 909.131.5599 • Fax: 909737.0330