Loading...
HomeMy WebLinkAbout2101 COSTA DEL MAR RD; ; AS07003010/6/2020 AS070030 Permit Data City of Carlsbad Sprinkler Permit 2101 COSTA DEL Job Address: MAR RD Permit Type: SPRINK Parcel No: 2165900100 Lot #: 0 Reference No.: Permit No: AS070030 Status: ISSUED Applied 2/5/2007 Approved: 2/5/2007 Issued: 2/5/2007 PC #: Inspector: Project Title: FAMILY POOL/LA COSTA RESORT TWO FIRE SPRINBKLER INSPECTIONS @ $62/EA Applicant: Owner: COSCO FIRE PROTECTION K S L LA COSTA RESORT CORP 10695 TREENA ST SAN DIEGO, CA 50-905 AVENIDA BERMUDA• LAQUINTACA 858-444-2000 Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 1/1 THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT FILE Copy p tire i-roieciion oy uomptxer ue.yn COSCO FIRE PROTECTION 10695 TREENA STREET STE 105 SAN DIEGO, CA. 92131 858-444-2000 Job Name : la costa family pool Building : Location : REMOTE AREA I System Contract Data File : LA-COSTA.wxl Mo-q-oo-3c> Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 COSCO FIRE PROTECTION Page la costa family pool Date 120906 Hydraulic Design Information Sheet Name - LA COSTA FAMILY POOL Location - REMOTE AREA 1 Building - Contractor - Calculated By - JUSTIN SHELTON Construction: ( ) Combustible Occupancy - (X) Non-Combustible Date - 12/11/06 System No. - Contract No. - Drawing No. - Ceiling Height - 81 -0" (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 (.) 3 ( ) Ex.Haz. NFPA 231 NFPA 231C ( ) Figure Curve Other Specific Ruling Made By Date Area of Sprinkler Operation - ENTIRE System Type Sprinkler/Nozzle Density - .10 (X) Wet Make VIKING Area Per Sprinkler - 225 ( ) Dry Model MIRAGE Elevation at Highest Outlet - 8.00 ( ) Deluge Size 1/2" Hose Allowance - Inside - ( ) Preaction K-Factor =EQ01 Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 Hose Allowance - Outside - Note Calculation Flow Required - 216.20 Press Required - 42.011 AT BOR Summary C-Factor Used: 120 Overhead 120 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 130 @ Press - R Residual Press - 91.8 Elev. - Well Flow - 614 Proof Flow S Elevation - 0 U P Location - P L Source of Information - EXISTING CALC CARD INFO Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M C ) Single Row C ) Conven. Pallet C ) Auto. Storage C ) Encap. S R C ) Double Row C ) Slave Pallet C ) Solid Shelf • ( ) Non T A ( ) Mult. Row ( ) Open Shelf 0 R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 S Y S T E M D E S I G N Water Supply Curve (C) COSCO FIRE PROTECTION Page 2 la costa family pool Date 120906 City Water Supply: Demand: Cl - Static Pressure : 130 Dl - Elevation : 3.465 C2 - Residual Pressure: 91.8 - D2 - System Flow : 216.202 C2 - Residual Flow : 614 02- System Pressure : 45.683 Hose (Adj City) Hose ( Demand) 03- System Demand : 216.202 Safety Margin : 78.778 150 Cl 140 130 T p120 R11° E10° -- C2 S90 S80 U 70 R60:. 02 E 50 40 30 20 10 i. - .Q4... . 100 200 300 400 500 600 700 800 900 FLOW (Ntt 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 120906 14 16 18 20 24 35 40 45 50 61 71 81 91 101 121 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ptessure / Flow Summary - STANDARD COSCO FIRE PROTECTION Page 4 la Costa family pool Date 120906 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Ran DOOI 8.0 5.6 7.0 na 14.82 D002 8.0 5.6 7.0 na 14.82 21 8.0 K = K @ EQ02 23.34 na 26.63 20 8.0 K = K @ E002 30.93 na 30.66 19 8.0 K = K @ EQ01 7.22 na 14.82. 18 8.0 K = K © EQ02 8.03 na 15.62 17 8.0 K=K@EQO2 9.7 na 17.17 16 8.0 KK@EQO2 11.17 na 18.42 15 8.0 K = K © EQ02 20.92 na 25.21 14 8.0 K = K © EQ02 22.06 na 25.89 11 8.0 K= K @ EQ02 23.26 na 26.58 12 8.0 24.56 na 13 8.0 32.52 na 1 - 8.0 K = K © EQ02 7.61 - na 15.2 2 8.0 7.97 na 3 8.0 8.85 na 4 8.0 10.67 na 5 8.0 . 11.97 na 6 8.0 22.9 na 7 8.0 24.17 . na 8 8.0 38.56 na 9 8.0 39.07 na 10 8.0 42.01 na TEST 0.0 45.68 na The maximum velocity is 30.15 and it occurs in the pipe between nodes 5 and 6 0.1 130 7.0 0.1 130 7.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fihal Calculations Hazen-Williams COSCO FIRE PROTECTION la costa family pool Page 5 Date 120906 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn DOOI 14.82 1.049 1E 2.0 1.000 7.000 K Factor= 5.60 to 120 0.0 2.000 0.0 EQOI 14.82 0.0747 0.0 3.000 0.224 Vet = 5.50 0.0 14.82 7.224 K Factor = 5.51 0002 14.82 1.049 1 2.0 1.000 7.000 K Factor= 5.60 to 120 0.0 2.000 0.0 EQ02 14.82 0.0747 0.0 3.000 0.224 Vet = 5.50 0.0 14.82 7.224 KFactor= 5.51 21 26.63 1.049 IT 5.0 0.550 23.337 K Factor © node EQ02 to 120 0.0 5.000 0.0 12 26.63 0.2211 0.0 5.550 1.227 Vet = 9.89 0.0 26.63 . 24.564 K Factor = 5.37 20 30.66 1.049 IT 5.0 0.550 30.926 . K Factor © node EQ02 to 120 0.0 5.000 0.0 13 30.66 0.2868 0.0 5.550 1.592 Vel = 11.38 0.0 30.66 . . 32.518 K Factor = 5.38 19 14.82 1.049 IT 5.0 4.920 7.224 K Factor © node EQOI to 120 0.0 5.000 0.0 2 14.82 0.0747 0.0 9.920 0.741 Vel = 5.50 0.0 14.82 7.965 K Factor = 5.25 18 15.62 1.049 IT 5.0 4.920 8.031 K Factor@ node EQ02 to 120 0.0 5.000 0.0 3 15.62 0.0824 0.0 9.920 0.817 Vet = 5.80 0.0 15.62 8.848 K Factor = 5.25 17 17.17 1.049 . IT 5.0 4.920 9.701 K Factor @ node EQ02 to 120 0.0 5.000 . 0.0 .4 17.17 0.0981 0.0 9.920 0.973 Vel = 6.37 0.0 17.17. 10.674 K Factor= 5.26 16 18.42 1.049 iT 5.0 2.170 11.170 K Factor@ node EQ02 to 120 . 0.0 5.000 0.0 5 18.42 0.1117 0.0 . 7.170 0.801 Vet = 6.84 0.0 18.42 11.971 K Factor= 5.32 15 25.21 1.049 IT 5.0 4.890 20.921 . K Factor@ node EQ02 to 120 0.0 5.000 0.0 6 25.21 0.1998 0.0 9.890 1.976 Vel = 9.36 .0.0 25.21 22.897 K Factor = 5.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FnaI Calcul'ations L Standard COSCO FIRE PROTECTION Page 6. la costa family pool . . Date 120906 Hyd.. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt . Pf/Ft Eqv. Ln. Total Pf Pn 14 25.89 1.049 IT 5.0 5.090 22.055 K Factor @ node EQ02 to 120 0.0 5.000 0.0 7 25.89 0.2098 0.0 10.090 2.117 Vel = 9.61 0.0 25.89 24.172 KFactor 5.27 11 26.58 1.049 0.0 5.940 23.255 K Factor @ node EQ02 to 120 0.0 0.0 0.0 12 26.58 0.2204 0.0 5.940 1.309 Vel = 9.87 12 26.63 1.049 0.0 10.000 24.564 to . 120 0.0 0.0 0.0 13 53.21 0.7954 0.0 10.000 .7.954 Vel = 19.75 13 30.66 1.38 1 3.0 4.490 32.518 to 120 iT 6.0 9.000 0.0 9 83.87 0.4854 0.0 13.490 6.548 Vel = 17.99 0.0 83.87 . 39.066 K Factor= 13.42 1 15.20. 1.049 1 E 2.0 2.590 7.606 K Factor @ node EQ02 to . 120 0.0 2.000 0.0 2 15.2 0.0782 0.0 4.590 0.359 . Vel = 5.64 2 14.82 1.049 0.0 3.200 7.965 to . 120 . 0.0 0.0 0.0 3 . 30.02 0.2759 0.0 3.200 0.883 Vel = 11.14 3 15.62 1.049 0.0 3.050 8.848 to 120 0.0 0.0 0.0 4 . 45.64 0.5987 0.0 3.050 1.826 Vel = 16.94 4 17.17 1.049 0..0 1.200 10.674 to 120 0.0 0.0 0.0 5 62.81 1.0808 0.0 1.200 1.297 . Vel = 23.32 5 18.42 1.049 0.0 6.280 11.971 to 120 0.0 0.0 0.0 6 81.23 1.7398 0.0 6.280 10.926 Vel = 30.15 6 25.22 1.38 0.0 1.690 22.897 to . 120 0.0 0.0 0.0 7. 106.45 0.7544 0.0 . 1.690 1.275 Vel = 22.83 7 25.88 1.38 1E 3.0 3.750 24.172 to 120 IT 6.0 9.000 0.0 8 132.33 1.1285 0.0 12.750 14.389 Vel = 28.39 8 0.0 3.26 2E 18.815 10.620 38.561 to 120 0.0 . 18.815 0.0 9 132.33 0.0172 0.0 29.435 0.505. Vel = 5.09 9 83.87 3.26 4E 37.631 11.450 39.066 to 120 IT 20.159 57.790 0.0 10 216.2 0.0425 0.0 69.240 2.945. Vel = 8.31 10 0.0 4.26 0.0 17.870 42.011 to 120 0.0 0.0 3.465 TEST 216.2 0.0116 0.0 17.870 0.207 Vel = 4.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Frnal Calculations Standard COSCO FIRE PROTECTION Page 7 la Costa family pool Date 120906 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 216.20 45.683 K Factor= 31.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Fire Protection by Computer Design COSCO FIRE PROTECTION 10695 TREENA STREET STE 105 SAN DIEGO, CA. 92131 858-444-2000 Job Name : la costa family pool area 2 Building Location : REMOTE AREA 2 System Contract Data File : LA-COSTA.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 COSCO FIRE PROTECTION Page la costa family pool area 2 Date 121106 Hydraulic Design Information Sheet Name - LA COSTA FAMILY POOL Location - REMOTE AREA 2 Building - Contractor - Calculated By - JUSTIN SHELTON Construction: ( ) Combustible Occupancy - (X) Non-Combustible Date - 12/11/06 System No. - Contract No. - Drawing No. - Ceiling Height - 81 -0" (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 C ) 3 C ) Ex.Haz. NFPA 231 NFPA 231C ( ) Figure Curve Other Specific Ruling Made By Date Area of Sprinkler Operation - 901 System Type Sprinkler/Nozzle Density - .15 (X) Wet Make VIKING Area Per Sprinkler - 130 ( ) Dry Model MOCROFAST Elevation at Highest Outlet - 8.00 ( ) Deluge Size 1/2" Hose Allowance - Inside - ( ) Preaction K-Factor =EQ01 Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 Hose Allowance - Outside - Note Calculation Flow Required - 269.00 Press Required - 77.964 AT BOR Summary C-Factor Used: 120° Overhead 120 Underground Water Flow Test: Date of Test - Time of Test - Static Press - 130 Residual Press - 91.8 Flow - 614 Elevation - 0 cation - Source of Information - EXISTING CALC CARD INFO Commodity Class Location Storage Ht. Area Aisle W. Storage Method: Solid Piled Palletized % Rack Single Row C ) Conven. Pallet C ) Auto. Storage ( ) Encap. R C ) Double Row ( ) Slave Pallet C ) Solid Shelf C ) Non A ( ) Mult. Row C ) Open Shelf C K Flue Spacing Clearance:Storage to Ceiling Longitudinal ° Transverse Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 S Y S T E M D E S I G N W A T E R S U P P L Y C 0 M M S T 0 R A G E Pump Data: Rated Cap.- @ Press - Elev. - Tank or Reservoir: Cap. - Elev.- Well Proof Flow Water Supply Curve (C) COSCO FIRE PROTECTION Page 2 la costa family pool area 2 Date 121106 City Water Suppjy: Demand: Cl - Static -'ressure : 130 Dl - Elevation : 3.465 C2 - Residual Pressure: 91.8 D2 - System Flow : 268.997 C2 - Residual Flow : 614 D2 - System Pressure : 81.739 Hose (Adj City) Hose ( Demand) 03- System Demand : 268.997 - Safety Margin : 39.963 150 140 Cl 130 z P 120 R•110 E'00 C2 S 90 D2 U 70 R60 / E 50 40 30 10 100 200 300 400 500 600 700 800 900 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary COSCO FIRE PROTECTION Page 3 la costa family pool area 2 Date 121106 Fitting Legend Abbrev.. Name 1/2 % 1 1% 1'/2 2 21A 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T 90 Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 PrQssure I IIow Simmary - STANDARD COSCO FIRE PROTECTION Page 4 la Costa family pool area 2 Date 121106 Node No. Elevation K-Fact Pt Actual Pn Flow Actual • Density Area Press Req. 56 8.0 5.6 35.73 na 33.47 0.15 130 7.0 55 8.0 5.6 12.95 na 20.15 0.15 130 7.0 53 8.0 5.6 17.36 na 23.33 0.15 130 7.0 54 8.0 5.6 19.65 na 24.82 0.15 130 7.0 51 8.0 5.6 22.88 na 26.78 0.15 130 7.0 52 8.0 5.6 25.11 na 28.06 0.15 130 7.0 49 8.0 5.6 28.48 na 29.89 0.15 130 7.0 50 8.0 5.6 31.22 na. 31.29 0.15 130 7.0 47 8.0 5.6 32.03 na 31.69 0.15 130 7.0 48 8.0 37.71 na 40 8.0 5.6 12.13 na 19.5 0.15 130 7.0 41 8.0 13.72 na 42 8.0 23.53 na 43 8.0 30.05 na 44 8.0 37.26 na 45 8.0 41.78 na 46 8.0 70.3 na 8 8.0 74.16 na 9 8.0 74.84 na 10 8.0 77.96 na TEST 0.0 81.74 na The maximum velocity is 25.72 and it occurs in the pipe between nodes 45 and 46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations'- Hazen-Williams COSCO FIRE PROTECTION Page 5 la costa family pool area 2 Date 121106 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total .Pf Pn 56 33.47 1.049 IT 5.0 0.870 35.729 K Factor = 5.60 to 120 6.0 5.000 0.0 48 33.47 0.3375 0.0 5.870 1.981 Vel = 12.42 0.0 33.47 37.710 K Factor = 5.45 55 20.15 1.049 IT 5.0 0.870 12.949 K Factor= 5.60 to 120 0.0 5.000 0.0 41 20.15 0.1320 0.0 5.870 0.775 Vel = 7.48 0.0 20.15 13.724 K Factor = 5.44 53 23.33 1.049 2E 4.0 9.250 17.358 K Factor = 5.60 to 120 0.0 4.000 0.0 54 23.33 0.1731 0.0 13.250 2.293 Vel = 8.66 54 24.83 1.049 IT 5.0 0.870 19.651 K Factor = 5.60 to 120 0.0 5.000 0.0 42 48.16 0.6612 0.0 5.870 3.881 Vel = 17.88 0.0 48.16 23.532 K Factor = 9.93 51 26.78 1.049 2E 4.0 6.000 22.876 K Factor = 5.60 to 120 0.0 4.000 0.0 52 26.78 0.2234 0.0 10.000 2.234 Vet = 9.94 52 28.07 1049 IT 5.0 0.870 25.110 K Factor= 5.60 to 120 0.0 5.000 0.0 43 54.85 0.8412 0.0 5.870 4.938 Vel = 20.36 0.0 54.85 30.048 KFactor= 10.01 49 29.89 1.049 2E 4.0 6.000 28.484 K Factor = 5.60 to 120 0.0 4.000 0.0 50 29.89 0.2736 0.0 10.000 2.736 VeI= 11.10 50 31.29 1.049 IT 5.0 0.870 31.220 K Factor = 5.60 to 120 0.0 5.000 0.0 44 61.18 1.0296 0.0 5.870 6.044 Vel = 22.71 0.0 61.18 37.264 KFactor= 10.02 47 31.69 1.049 4E 8.0 10.620 32.031 K Factor= 5.60 to 120 0.0 8.000 0.0 48 31.69 0.3050 0.0 18.620 5.679 Vel= 11.76 48 33.48 1.38 . IT 6.0 7.370 37.710 to 120 0.0 6.000 0.0 .45 65.17 0.3043 0.0 13.370 4.069 . Vel = 13.98 0.0 65.17 41.779 . KFactor= 10.08 40 19.50 1.049 IE 2.0 10.870 12.125 K Factor =5.60 to 120 0.0 2.000 0.0 41 19.5 0.1242 0.0 12.870 1.599 Vel = 7.24 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard COSCO FIRE PROTECTION Page 6 la costa family pool area 2 Date 121106 Hyd. Qa Diá. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 41 20.15 1.049 IE 2.0 19.250 13.724 to 120 0.0 2.000 0.0 42 39.65 0.4616 0.0 21.250 9.808 Vel = 14.72 42 48.16 1.38 0.0 12.330 23.532 to 120 0.0 0.0 0.0 43 87.81 0.5285 0.0 12.330 6.516 Vel = 18.84 43 54.84 1.61 0.0 11.790 30.048 to 120 0.0 0.0 0.0 44 142.65 0.6120 0.0 11.790 7.216 Vet = 22.48 44 61.18 2.067 IT 10.0 2.870 37.264 to 120 0.0 10.000 0.0 45 203.83 0.3508 0.0 12.870 4.515 Vet = 19.49 45 65.17 2.067 4E 20.0 18.660 41.779 to 120 IT 10.0 30.000 0.0 46 269.0 0.5861 0.0 48.660 28.520 Vet = 25.72 46 0.0 3.26 4E 37.631 22.950 70.299 to 120 0.0 37.631 0.0 8 269.0 0.0637 0.0 60.581 3.861 Vet = 10.34 8 0.0 3.26 0.0 10.620 74.160 to 120 0.0 0.0 0.0 9 269.0 0.0637 0.0 10.620 0.677 Vet = 10.34 9 0.0 3.26 4E 37.631 11.450 74.837 to 120 0.0 37.631 0.0 10 269.0 0.0637 0.0 49.081 3.127 Vet = 10.34 10 0.0 4.26 0.0 17.870 77.964 to 120 0.0 0.0 3.465 TEST 269.0 0.0173 0.0 17.870 0.310 Vet = 6.06 0.0 269.00 81.739 K Factor= 29.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 October 6, 2006 Sprinkler 54a The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com DESCRIPTION Viking Mirage® Quick Response Concealed Pendent Sprinkler SIN VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinkler designed for installa- tion on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to Y2" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The 'push-on', 'thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. LISTINGS AND APPROVALS cULus Listed: Category VNIV NYC Approved: MEA 89-92-E, Volume 32 Refer to the Approval Chart on page 54c and Design Criteria on page 54d for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to Viking Technical Data may be found on 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) The Viking Corporation's Web site at sprinklers can be identified by locating "250" stamped on the deflec- http:llwww.vikingcorp.com. tor. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp The Web site may Include a more recent Factory tested hydrostatically to 500 psi (34.5 bar) I edition of this Technical Data Page. Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2"(15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 OF (-55 'C) Patents Pending Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30300 Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-GI 0080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover Copper UNS-C1 1000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Form No. F_103005 Replaces page 54a-b, dated April 10, 2006 (reformatted and added MEA/NYC Approval). Sprinkler 54b October 6, 2006 IrCONCEALED AGE® QUICK RESPONSE 1 PENDENT 4I I W*jl:II[.ru.7M PRINKLER VK463 (K5.6) RINKLER VK462 AND HP The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 289-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Sprinkler: Base Part No. 13503A or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number Temperature Suffix (°F/°C): 1550/68" = B, 175779° = D, 200°/93° = E For example, sprinkler VK462 with a 155 017168 "C temperature rating = 13503AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter) or Base Part No. 13642 (3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number Finish Suffix: Polished Chrome = F, Painted White = M-/SWI 004, Painted Ivory = M-/SW1634, Painted Black = M-/SWI 007 Temperature Suffix (°F/°C): 135°/57° =A. 165774° = C For example, cover 13504 with a Polished Chrome finish and a 165 "Ff74 "C temperature rating = 13504FC. Available Finishes And Temperature Ratings: Refer to Table I Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches": Heavy Duty Part No. 14047W/B (available since 2006), or Light Duty Part No. 14031*** (available since 2006) **Requires a W ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: live (5) sprinklers (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers SIN VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. 2-1/4" (57.2 mm)diameter opening Is required in the ceiling. Sprinkler and Adapter Assembly (Protective Cap Is removed for installation--use Wrench 14031ww) Sprinkler Wrench (Part No. .4047W/Bee Is shown) Step It Carefully slid wrench sideways or the deflector and Step 2' Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrench, Viking Part Number 14047W/B or 14031. DO NOT apply more than 25 ft. tbs. of torquie. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond Finger tight. October 6, 2006 Sprinker 54c MIRAGE® QUICK RESPONSE CONCEALED PENDENT JIF(II*1G lsi:II[u.7MA SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com kler NPT Thread Nominal Maximum Overall Length Listings and Approval84 FBasePart SIN Size K-Factor Water Working (Sprinkler Body) (Refer also to Design Criteria on page 54d.) ber1 Inch I mm i Pressure U.S. I met Inches i mm cULus5 I FM I NYC6 I VdS I LPCB 13503A VK462 1/2" 15 5.6 I 80.6 175 psi (12 bar) 2-3/16" 56 AWl, BXI I -- AWl, BXI -- - 13667A VK463 1/2" 1 15 5.6 80.6 250 psi (17.2 bar)3 2-3/16" J 56 AWl, BXI - AWl, BXI -- - Sprinkler Temperature Ratings cover Plate Assembly Temp. Ratings Finishes of the Cover Plate Assembly7 I A - 155 "F (68 °C) W - 135 °F (57 "C) cover 135041 or 136421 (Jarge diameter) - Polished Chrome, Painted6 White (No. B - 175 "F (79"C) and 200 "F (93 "C) X - 165 °F (74 °C) cover 13504' or 13642' (large diameter) 1004)9, Painted" Ivory (No. 1634)9, or Painted8 Black (No. 1007) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, dMde the metric K-factor shown by 10.0. 3 The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. The 135 "F cover has an orange label. The 165 °F cover has a white label. B Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. 9 Sherwin-Williams* Color AnswersTm Interior Color Number. seA 1/2" ratchet is required (not available from Viking). Figure 1: Sprinkler Installation and Correct Use of Wrenches 2-1/4' (57.2 mm) diameter opening Is required in the ceiling. Sprinkler and Adapter Assembly (Protective Cap Is removed for installation--use Wrench 14O31ww) Sprinkler Wrench (Part No. 4047W/Be' Is shown) Step It Carefully slid wrench sideways or the deflector and Step 2' Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the Sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrench, Viking Part Number 14047W/B or 14031. DO NOT apply more than 25 ft. tbs. of torquie. A teak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler 54d October 6, 2006 MIRAGE® QUICK RESPONSE CONCEALED PENDENT 'sI IF(.I I1G SPRINKLER VK463 (K5.6) SPRINKLER VK462 AND HP The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Mirage® Quick Response Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below: Must be installed in neutral or negative pressure plenums only. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. "A 1/2' ratchet is required (not available from Viking). Figure 2: Sprinkler Dimensions and Cover Installation Form No. F_I 03005 Replaces page 54a-b, dated April 10, 2006 (reformatted and added MENNYC Approval). August 4, 2006 . Sprinkler 41 a PRODUCT NAME MICROFAST® AND MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS tThe Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 Technical Services: (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs©vikingcorp.com PRODUCT DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small themiosensitive glass bulb spray sprinklers available in various finishes, temperature ratings, and orifice sizes to meet design requirements. The special Poly finishes and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these finishes have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Poly finishes as corrosion resistant.) The pip cap and sealing assembly of the sprinkler are held in place by the glass bulb operating element. During fire con- ditions, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. TECHNICAL DATA LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 Refer the Approval Chart on page 41 c and Design Criteria on page 41 d for cULus and FM approval requirements that must be followed. CHARACTERISTICS Minimum Operating Pressure: 7 psi (0,5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0,5 bar) up to 250 psi (17,2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested, hydrostatically to 500 psi (34,5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 F (-55 °C) Overall Length: Refer to the Approval Chart MATERIALS Frame Casting: Brass UNS-C84400 Deflector Brass UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Note: Units of measure in parentheses may be approximations. Replaces page 41 a-b, dated November 18, 2005 (Reformatted, added Form No. F_081296 135 T temperature rating, and added CE approval for sprinkler 06666B.) Sprinkler 41 b August 4, 2006 TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 7(57 -C) 100 °F (38 °C) Orange Ordinary 155 100 "F (38 "C) Red Intermediate 175 "F (79 "C) 150 °F (65 "C) Yellow Intermediate 200 ¶ (93 "C) 150 °F (65 °C) Green High 286 °F (141 "C) 225 °F (107 "C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester (White Poly finish for Sprinkler 06662B), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® Corrosion-Resistant Coatings3: White Polyester (White Poly finish for Sprinkler 06662B only), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on page 41 c. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Poly finishes and Teflon® coatings. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Poly Coated Sprinklers', Belleville Spring-Exposed AVAILABLE FINISHES AND TEMPERATURE RATINGS: Refer to Table I above. 5. ORDERING INSTRUCTIONS (Also refer to the current Viking price list.) Order Microfast® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Poly Finish = M-/W, Black Poly Finish = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 1350I680 =A, 1550I68° = B, 175°/79° = 0, 2000/930 = E, and 266°I141° = G For example, Sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06662BAB. ACCESSORIES (Also refer to the "Sprinkler Accessories" section of the 'liking data book) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: Recessed pendent sprinklers with protective caps must use wrench 12144W1B. ""A ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) August 4, 2006 Sprinkler 41 c Nominal Listings and Approvals3 Base Part Thread Size Overall Lengtii SIN K-Factor (Refer also to Design Criteria on page 41 d.) Number NPT I BSP u.s. I metric2 Inches mm cULus4 I FM5 NYC' I VdS I LPCB I CE I Standard Orifice 06662B I VK302 1 1/2" 115 mm 1 5.6 I 80,6 I 2-1/4 1 58 JAIX, B1YIA4X, B4YIAIX, B1YI F2 I A4X IC4X, D4Y121 C4X, D4Y14 Large Orifice 066666 VK352 3/4" 20 mm 8.0 115,2 2-3/8 60 A3X, B3Y A2X, B 2Y A3X, B3YJ I - E412 I - 12104 1 VK352 3/4" 120mm 1 8.0 115,2 1 2-1/4 58 1 - -- - F2 I - - 06765B I VK352 1/2" 115mm I 8.0 115,2 1 2-3/8 60 IA3X,B3YI A3X, B3Y - - - Small Orifice8 06718B9 VK329 1/2" 115 mm 1 2.8 40,3 3X,B3YJ A2X A3X, B3Y - - - 06720B9 VK331 1/2" 15 mm 1 4.2 60,5 2-1/4 58 1 A3X, 133Y - A3X, B3Y - - - 069326 VK331 - 10 mm 1 4.2 60,5 2-3/8 60 1 - -- -- F2 - F213 - Maximum 250 PSI (17,2 bar) WWP Standard Orifice Base Part Thread Size Nominal Overall Listings and Approvals3 Number SIN K-Factor g58A'3X,B3YJ (Refer also to Design Criteria on page 41 d.) NPT BSP U.S. metrIc2 Inches ULus4 FM NYC' ° VdS LPCB CE 12282 VK317 1/2" 15mm 5.6 80,6 2-1/4 - A3X - - - - Maximum 250 PSI (17,2 bar) WWP Small Orifice8 122909 I VK342 11/2" 115 mm I 2.8 I 40,3 1 2-3/16 I 56 IA3X, B3YI - I A3X I Approved Temperature Ratings A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), Approved Escutcheons 200 OF (93 "C), and 286 OF (141°C) Approved Finishes X - Standard surface-mounted escutcheon B -135°F (57 °C), 155°F (68 °C), 175°F (79 °C), I - Brass, Chrome-Enloy®, White Poly Finish?, or the Viking Microfast® Model F-I and 200 OF (93 °C) Black Poly Finish7, and Black Teflon67 Adjustable Escutcheon" C -155°F (68 °C), 175°F (79 "C), 200°F (93 °C), 2 - Brass and Chrome-Enloy® Y - Standard surface-mounted escutch- and 286 OF (141°C) 3 - Brass, Chrome-Enloy®, White Polyester7, eon or the Viking Microfast® Model D - 155 OF (68 °C), 175 OF (79 °C), and 200 OF Black Polyester7, and Black Teflon87 F-I Adjustable Escutcheon" or re- (93 °C) 4 - Brass, Chrome-Enloy®, White Poly Finish, cessed with the Viking Micro- E - 155 OF (68 °C), 175 OF (79 °C), and 286 OF and Black Poly Finish matic® Model E-1 or E-2 Recessed (141°C) Escutcheon F - 155°F (68 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. ' Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 6Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 7cULus Listed as corrosion resistant. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. The sprinkler orifice is bushed. '°Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol XVI. "The Viking Microfast® Model F-I Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 12 CE Certified, Standard EN 12259-I, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130. 14.® MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. - Wrench 12144W/B for installing coated and/or recessed sprinklers with protective caps. Carefully slide the wrench sideways around the protective A 1/2" ratchet is required cap, ensuring engagement (not available from Viking). with the sprinkler wrench flats. Wench Flat Protective Sprinkler Cap Sprinkler 41 d August 4, 2006 cULus Listing Quick Response Pendent Sprinklers are cU!s Listed as indicated in the Approval Part for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM ADoroval Requirements: Quick Response Pendent Sprinklers are FM Approved as indicated in the Approval Chart for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems). For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-2 for general care, installation, and maintenance Information. Viking sprinklers are to be Installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Pleniere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 1: Standard Sprinkler Wrench I089BWIB Figure 2: Wrench 12144W/B for Installing Coated and/or and Recessed Pendent Sprinklers August 4, 2006 Sprinkler 41 e Ceiling Opening Size: 2-5/16" (59 mm) Minimum, I 2-1/8" 1 2-1/2"(64 mm) Maximum. (54 mm) 1/2' t (15m NPT 2-1/4" 1-3/4'(58 mm) Pendent Sprinkler 06662B 1-3/4" (44,5 mm) Pendent Sprinkler 06662B Installed with a Standard 1/8' (3,1 mm) Surface-Mounted Escutcheon F(38,1 2' (50,8mm) mm) Maximum irum Pendent Sprinkler 06662B Installed with the Microfast® Model F-I Adjustable Escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: I 2-1/8' I 2-5/16" (59 mm) Minimum, I 2-1/8" I [a (54 mm) 2-112"(64 mm) Maximum. (54mm) 13/4" Minimum I \ 1-1/8"(28,6 mm) (44,5 mm) Maximum Pendent Sprinkler 06662B Installed with the Micromatic® Model E-1 Recessed Escutcheon 2' I 1-118' (28,6 mm) (50,8 mm) Minimum Maximum ____________ Pendent Sprinkler 06662B Installed with the MicromatkP Model E-2 Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons THIS PAGE INTENTIONALLY LEFT BLANK Replaces page 41 a-b, dated November 18, 2005 (Reformatted, added Form No. F_081296 135 F temperature rating, and added CE approval for sprinkler 0666613.) PRODUCT NAME MICROFAST®AND MicrofastHPe QUICK RESPONSE UPRIGHT AND CONVEN- TIONAL SPRINKLERS tThe Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 Technical Services: (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcs@vikingcorp.com August 4, 2006 Sprinkler 51 a PRODUCT DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional (Old Style) Sprinklers are small thermosensitive glass bulb spray sprinklers available in various finishes, temperature ratings, and orifice sizes to meet design requirements. The special Poly finishes and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these finishes have been investigated for in- stallation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Poly finishes as corrosion resistant.) The pip cap and sealing assembly of the sprinkler are held in place by the glass bulb operating element. During fire con- ditions, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. TECHNICAL DATA LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 Refer the Approval Chart on page 51 c and Design Criteria on page 51 d for cULus and FM approval requirements that must be followed. Minimum Operating Pressure: 7 psi (0,5 bar) Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for use with water working pressures ranging from the minimum 7 psi (0,5 bar) up to 250 psi (17,2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating 11250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34,5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 OF (-55 °C) Overall Length: Refer to the Approval Chart MATERIALS Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-CI 9500 for Sprinklers 06661 B, 06665B, 06764B, 07060, and 12281. Brass UNS-C26000 for all other Sprinklers. Note: UnitS of measure in parentheses may be approximations. Replaces page 51 a-b, dated November 18, 2005 Form No. F080488 (Reformatted, added 135 OF temperature rating, and - added CE approval for sprinklers 06665B and 06768B.) L Sprinkler 51 b August 4, 2006 MICROFAST® AND Microfasti-1129 QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS TABLE 1: AVAILABLE SPRINKLER•l!aI1jrIuI:4lhlI RATINGS 4I'I * IL Ordinary 135 F (57 C) 100 F (38 C) Orange Ordinary 155 °F (68 °C) 100 F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 C) 150 ¶ (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester (White Poly finish for Sprinklers 06661 B, 06665B, 06764B, 07060, and 12281), Black Polyester (Black Poly finish for Sprinkler 06661 B), and Black Teflon® Corrosion-Resistant Coating83: White Polyester (White Poly finish for Sprinklers 06661B, 06665B, 06764B, 07060, and 12281), Black Polyester (Black Poly finish for Sprinkler 06661 B), and Black Teflon® The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on page 51 C. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Poly finishes and Teflon® coatings. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Poly Coated Sorinklers: Belleville Spring-Exposed AVAILABLE FINISHES AND TEMPERATURE RATINGS: Refer to Table I above. 5. ORDERING INSTRUCTIONS (Also refer to the current Viking price list) Order Microfast® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Poly Finish = M-/W, Black Poly Finish = M-/B, and Black Teflon® = N Temperature Suffix (OF/0C): 1350/680 =A, 1550/680 = B, 175779° = 0, 200°I93° = E, and 286°/141° = C For example, Sprinkler VK300 with a 1/2" thread, Brass finish and a 155 "F/68 °C temperature rating = Part No. 06661 BAB. ACCESSORIES (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: A. Standard Wrench: Part No. 10896W/B (available since 2000). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 197 1) Twelve-head capacity: Part No. 01725A (available since 1971) August 4, 2006 Sprinkler 51 c ominal Overall Listings and Approvals3 MSIN : Threa I~K-Factor Size Length (Refer also to Design Criteria on page 51 d.) NPTI BSImetric8 Inches Imm I cULus4 I FM6 I NYC7 IVdSI LPCB I CE I Upright-Standard Orifice 06661B VK300 1/2' 15 m 5.6 1 80,6 12-3/161 56 1 A6 I A7 I A6 I - - - - 07060 IVK3451 -- 115mmi 5.6 1 80,6 2-3/16 1 56 1 A3 I - Dl I A7" I B177111 B713 Conventional-Standard Orifice 06766B IVK316I 1/2115 mml 5.6 I 80,6 1 2-3/16 1 56 I A5 I - I A5 I -- I A511 1135111 B515 Upright-Large Orifice 06665B IVK35013/4"1 15 mm 1 8.0 1 115,2 12-5/161 59 1 A4 I A3 I A4 I Dl I 06764B VK35011/2- 115 mm 8.0 1 115,2 12-5/161 59 1 A4 I -- A4 I - - - - Conventional-Large Orifice 06768B IVK354I3/4°I20mmI 8.0 I 115,2 12-5/161 59 I A5 I - I A5 I - I - I c5 1I - t'prlght-Small Orifices 1 VK32511/2"1 15 mm 1 2.8 1 40,3 2-3/16 56 11 2 1 Al A2 I - - - - 1 067171310 06719B'° IVK32711/2"1 15 mm 4.2 1 60,5 12-3/161 56 1 A2 I -- A2 I - - - - 06931B'uIVK3271 -- 110mml 4.2 1 60,5 12-3/161 56 1 -- - Dl Maximum 250 PSI (17,2 bar) WWP Upright-Standard Orifice Base Part Thread Nominal Overall Listings and Approval83 Number SIN Size K-Factor Lenqth (Refer also to Design Criteria on page 51 d.) NPT BSP U.S. metric2 inches mm cULus4 FM NYC8 VdS LPCB CE • 12281 VK315 1/2" 15mm 5.6 80,6 2-3/16 56 A2 - A2 - - - -- ______________________________________ Upright-Small Orifice' 1228610 IVK340I 1/2"I15 mml 2.8 I 40,3 1 2-3/16 56 1 A2 I - I A2 Approved Temperature Ratings Approved Finishes A - 135 (57 °C), 155 °F (68 °C), 175 °F (79 °C), ..Chrome-EnloyO, White Polyesters, Black Polyesters, and Black Teflon®5 200 F (93 C), and 286 F (141 C) 3 - Brass, Chrome-Enloy®, and White Poly Finish B -155°F (68 °C), 175 °F (79 °C), 200°F (93 °C), and Brass, Chrome-Enloy®, White Poly Finish5, Black Polyesters, and Black Teflon65 286 °F (141°C) Brass, Chrome-Enloy®, White Polyesters, and Black Polyesters C - 155 °F (68 °C), 175 °F (79 °C), and 286 °F (141°C) 6 - Brass, Chrome-Enloy®, White Poly Finish5, Black Poly Finish5, and Black Teflon®5 D - 155 °F (68 °C) 7 - Brass, Chrome-EnIoy®, White Poly Finish, and Black Poly Finish Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Mefric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. "Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion resistant. FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins 7 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 8 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. 10The sprinkler orifice is bushed. "CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 13 0 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1 008. Sprinkler 51 d August 4, 2006 CROFAST® AND NIKJNG* RESPONSE UPRIGHT AND ECONVEN TIONALL SPRINKLERS cULus Listina Reauirements: Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers.. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For con- ventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. FM Aooroval Reauirements: Quick Response Upright Sprinklers are FM Approved as indicated in the Approval Chart for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems). For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed In ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Plenlere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. - Sprinkler Wrench Cap Flat Protective ko~Dlw' 7MMMMI M Figure 1: Standard Sprinkler Wrench 10896W1B Replaces page 51 a-b, dated November 18, 2005 (Reformatted, added 135 ¶ Form No. F_080488 temperature rating, and added CE approval for sprinklers 06665B and 06768B.) C.I. THREADED FITTINGS FITTINGS DI,Ltiirn f,fStarpijw Prc.ducf. LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI 1316.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME /4. ....1• A 1316.14. THREADS ARE NPT PER ANSIIASME BI.20.1. tCAST lIRON 'r DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIM IONS WEIGHT - A - B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 CB900441 300 1.75 1.75 1.34 11/2 CB900551 300 1 1.94 1.94 1.80 2 CB900661 300 1 225 1 2.25 2.90 21/2 CB900771 300 1 2.70 1 2.70 14.75 L- L-- -, " ~~- - - - ~~ CAST1IRON :1 D. COUPLING NOMINAL SIZE (INCH) ITEM CODE * MAX. WORKING P.S.I. DIMENSION WEIGHT EACH A PIECE 1X1/2 CRC031 300 1.70 0.62 1X3/4 CRC032 300 1.70 0.80 9........ I NOMINAL SIZE (INCH) CAST :.]URED. 1 I ITEM CODE * 90 DEG. MAX. WORKING P.S.I. ELBOW DIM IONS WeGIrr' EACH A B PIECE 1X1!2 CB90031 300 1.26 1.36 0.64 1X314 C990032 300 1.37 1.45 0.87 1 1/4X1/2 CB90041 300 1.34 1.53 0.96 1 1/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 1 112x1 1/2 CB90051 300 1.41 1.66 1.17 1 112x3/4 C990052 300 1.52 1.75 1.28 1 112X1 C990053 300 1.65 1.80 1.51 1 112X1 1/4 C990054 300 1.82 1.88 1.62 2X1/2 C990061 300 1.49 1.88 2.00 2X314 C890062 300 1.60 1.97 2.05 2X1 CB90063 300 1.73 2.02 2.10 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 202 2.16 2.60 Page 38 CAST IRON STRAIGHT NOMINAL SIZE (INCH) ITEM CODE * MAX. WORKING P.S.I. IDIMENSIONS1 A B WEIGHT I EACH PIECE 1 CT333 300 1.50 1.50 1.21 11/4 CT444 300 1.75 1.75 1.87 11/2 CT555 1 300 1 1.94 1.94 1 2.51 2 CT666 300 225 225 3.96 21/2 CT777 1 300 1 2.70 2.70 6.45 CAST IRON 45 DEGREE I:I.1!q NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT I EACH PIECE A B 1 C945033 300 1.12 1 1.12 0.84 11/4 CB45044 300 1.29 1.29 1.40 11/2 I CB45055 300 1.43 1 1.43 1 1.80 2 1 CB450661 300 1.68 1 1.68 1 2.79 Li CASTlIRON IJPLUGS NOMINAL SIZE (INCH) I ITEM CODE * MAX. WORKING P.S.I. DIMBISION WEIGHT EACH PIECE A 1/2 CPL001 300 0.94 0.10 3/4 CPLOO2 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPLOO4 300 1.36 0.44 1 1/2 CPLOOS 300 1.45 0.62 2 CPLOO6 300 1.56 0.91 C.I. THREADED FITTINGS FITTINGS C (9 (~~ <*> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON ICROSS NOMINAL SIZE (INCH) I1TEk1I CODE MAX. WORKING P.S.I.A DIM B4SIONS WEGHT EACH PIECE - - B 1 CX033 300 1.50 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 112X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 CAST IRON REDUCING NOMINAL ITEM MAX. SIZE CODE WORKING (INCH) P.S.I. _______ DIMB1SIONS WDGFIT EACH PIECE A B C 1X1X112 CT331 300 -tw -tw -tsr 0.95 1X1X3/4 CT332 300 tT 13T 1.10 1X112X1 CT313 300 TS0 -T T30 1.08 1 X3/4X1 CT323 300 T3 Tr 1.18 1X1X1 114 CT334 300 TT iT tSF 1.52 1X1X1 1/2 CT335 300 TW TS 1.73 U. 1 114X1X112 CT431 300 t4 -Tr 1sr 1.17 1 114X1)W4 CT432 300 T4W TT T1 1.38 1 1I4X1X1 CT433 300 tsr iT 1.47 1 1/4XIX1 1/4 CT434 300 1.7 ir T75 1.80 1 114X1X1 1/2 CT435 300 1F• T T2 2.05 1 1/4X1 1/4X1/2 CT441 300 T4 T34 -ir 1.37 1 1/4X1 114X3/4 CT442 300 T45 T45 T2 1.54 1 1I4X1 1/4X1 CT443 300 T35 8- 735 8- iT 1.65 1 1/4X1 1/4X1 1/2 CT445 300 tF tRU tT 2.21 1 114X1 1I4X2 CT446 300 nr 115 Tö 2.55 1 172X1X1 CT531 300 141 14 T6F 1.41 f 1/2X1X3/4 CT532 300 13T 13T T7 1.65 1 1I2X1X1 - CT533 300 -130 TF 1.65 T 112X1X1 1/4 CT534 300 12 TT 1F 2.00 1 112X1X1 1/2 CT535 300 tr ti -tr 2.30 1 112X1 114X112 CT541 300 r4r tr TU 1.58 1 1!ZX1 1I4X314 CT542 300 t5T 1 43 T71 1.72 1 112X1 1/4X1 CT543 300 tr IF 1 1/2x1 1/4x1 1/4 CT544 300 Tä T7 TW 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 tW 1.94 2.45 1 1/2X1 1!4X2 CT546 300 2.16 2.10 2.02 2.80 1 112X1 1/2X1/2 CT551 300 1.41 1.41 -1r 1.76 1 112X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1 1.94 1 112X1 1/2X1 1/4 CT554 300 TY 11 TäW 229 1 112X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 1 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 1 2.80 2X1 112X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 112X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 1 2.54 2X1 112X1 1/4 CT654 300 1.90 1.82 2.10 1 2.85 2X1 112X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 225 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 2.02 2.97 2X2X1 1/4 CT664 300 2.10 3.32 2X2X1 1/2 CT665 300 n9-Rn 2.16 3.72 2x2x2 1/2 CT667 300 Page 39 I SCHEDULE- 10/40 Schedule-1O®/Schedule-40 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (l"- 8") pipe and Sch-40 (1"- 2'4") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-I0/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Sch-40 Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pcs/ WtiLift (21') WtlLift (24') WtlLift (25' In; mm In, mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg 1' 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11/4' 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1½" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21h' 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications NPS Nominal I.D. Wt. Wt. (1120 Filled) Pcs/ 01.1111 (21') Wtllift (24') WIIUft (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Us; Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 25 279 2.1 2.70 91 1,213 1,385 1,445 11/4' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1½' 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21h' 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tqCo/Flow Control Qr allied TUBE & CONDUIT (9 <~> @ Listed Approved Listed 16100 S. Lathrop Harvey, IL 60426 Customer Service: 11350 Norcom Rd. 'Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5-3 11.02 VICTAULICO IS AN ISO 0001 CERTIFIED COMPANY Styles 920 and 920N Mechanical-T® Bolted Branch Outlets PRODUCT DESCRIPTION Victaulic Mechanical-Ts Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder' locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized housings are available, supplied with plated bolts. Styles 920 and 920N All sizes of Style 920 and 920N are rated at 500 psi (3450 kPa) working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or polybutylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Style 920 Cross See Victaulic publication 10.01 for details. See chan' on page 4 for pressure ra!'ngs. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-395, grade 65-45-15, and ASTM A-536, grade 65-45-12, with orange enamel coating. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade °'E" EPDM EPDM (Green color code). Temperature range -30°F to +230°F (-34°C to +110°C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F (+30°C) and hot +180°F (+82°C) NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range -20°F to +180°F (-29°C to +82°C). Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F (+66°C) or for hot dry air over +140°F (+60°C). Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: (Styles 920 and 920N) Heat treated carbon steel zinc plated to ASTM B-633, track-head conforming to physical properties of ASTM A-i 83 minimum tensile 110,000 psi (758340 kPa). S REGISTEREOTRADEMuRK OFVICTAUUC - S COPYRIGHT 2003 VICTAULIC - PRINTED IN U.S.A. Victaulic Company ot America ' Phone: 1-800-PlCK-VlC (1-800-142-5842). Fax: 610-250-8817' e-mail:pickvic@victaulic.com Victaulic Company of Canada' Phone: 905-884-7444' Fax: 905-884-9774' e-mail: viccanada@viclaulic.com Victaulic Europe' Phone:32-9-381-1500' Fax: 32-9-380-4438' e-mail: viceuro@victaulic.be Victaulic America Latina' Phone: 610-559-3300• Fax: 610-559-3608' e-mail: vical@victaulic.com Victaulic Asia PaciIic• Phone: 65-6235-3035' Fax: 65-6235-0535• e-mail: vicap@victaulic.com 1480 REV F \,LtaUI iC DIMENSIONS ___Y -9J r-r_ Z :11 Styles 920 and 920N w/Grooved Outlet Styles 920 and 920N w!Female Threaded Outlet NOTE: Style 920 and Style 920N housings cannot be mated to achieve cross connections. These new size Style NEW 920N products require a HOLE SIZE different hole size than the Style 920 it replaces, for proper installation. Use caution to assure the proper size hole is prepared for the specific size and style used. Failure to use the proper hole size could result in joint leakage and property damage. Max. Dimensions - Inches/millimeters - - - - - Aprx. SIZE Work. Will. Each Hole Fern. Run X Branch Press. DIa. Thd. Gm - LbsJkg Fern. Nominal Inches Style PSI +0.13 V V mm No. kPa -0.00 1 W Y Z mci. Grv. 2 X /2 (a) 920N 500 1.50 200 2.53 - 1.63 4.91 250 3.1 - 50 X 15 3450 38,1 51 64 - 41 125 64 115 - X 3/4 (a) 920N 500 1.50 1.97 2.53 - 1.63 4.91 2.75 3.1 - X 20 3450 38,1 1 50 64 1 - 41 125 70 1.5 - 1(a) 500 150 1.81 253 - 1.63 491 275 30 - X 25 3450 38.1 46 64 - 41 125 70 1.4 - 920N 500 1.75 2.04 2.75 3.00 1.63 4.91 3.00 3.5 3.2 X 11/4 (a) t X 32 3450 44,5 52 70 76 41 125 76 13 1,5 X 11/2 (a) t 920N 500 1.75 2.03 2.75 3.12 1.63 4.91 3.25 3.6 3.2 X 40 3450 44,5 52 70 79 41 125 83 1,7 1.5 21/2 X 1/2 (a) 920N 500 1.50 2.21 2.74 - 1.82 5.14 2.75 3.0 - 65 X 15 3450 38.1 56 70 - 46 131 70 1.4 - 920N 500 1.50 2.18 2.74 - 1.82 5.14 2.75 3.0 - X 3/4 (8) X 20 3450 38.1 55 70 - 46 131 70 1.4 - X 1(a) 92 500 1.50 206 274 - 1.82 5.14 2.75 2 - X 25 3450 38,1 52 70 - 46 131 70 1.4 - X 11/4 t (a) 920N 3450 500 1.75 2.29 3.00 3.25 1.82 5.14 3.00 3.5 3.2 X 32 44,5 58 76 83 46 131 76 13 1.5 X 11/2 t (a) 920N 500 2.00 2.27 3.00 3.25 1.82 5.14 3.25 3.6 3.3 X 40 3450 50,8 58 76 83 46 131 83 1.7 1,6 76,1 mm X 1/2 (a) 920 300 1.50 2.22 2.75 2.25 6.50 3.18 3.9 - X 15 2065 38.1 56 70 - 57 165 81 1,8 - X 3/4 (a) 920 300 1.50 2.19 2.15 - 2.25 6.50 3.18 3.9 - X 20 2065 38,1 56 70 - 57 165 81 1.8 - X 1(a) 920 300 1.50 2.07 275 - 225 650 318 38 - X 25 2065 38,1 53 70 - 57 165 81 13 - X 11/4 (a) t 920N 500 1.75 2.25 3.00 3.25 1.92 5.67 3.00 3.5 3.2 X 32 3450 44,5 57 76 83 49 144 76 1,6 1,5 X 11/2 (a) 920N 500 2.00 2.25 3.00 3.25 1.92 5.67 3.25 3.5 3.3 X 40 3450 50.8 57 76 83 49 144 83 1,6 1.5 3 X 1/2 (a) 920N 500 1.50 2.53 3.06 - 2.29 5.15 2.75 3.4 - 80 X 15 3450 38,1 64 78 - 58 146 70 1.6 - X 3/4 (a) 920N 500 1.50 2.50 3.06 - 2.29 5.75 2.75 3.4 - X 20 3450 38,1 64 78 - 58 146 70 1,6 - X 1(a) 920N °° X 25 3450 38,1 60 78 - 58 146 70 1,6 - 11/4 (a) t 500 LTh 2.54 3.25 356 2.29 575 3.00 38 3.7 X 32(b) 3450 44.5 65 83 90 58 146 76 1.8 1.8 X 1'/2 (a) t 920N 500 2.00 2.77 350 3.56 229 5.75 325 4.1 3.8 X 40(b) 3450 50,8 70 89 90 58 146 83 1,9 1,8 2(a) 920N X 50 3450 63,5 70 89 90 58 146 99 2,3 2.1 33/2 X 2 920N 500 2.50 - - 3.75 2.44 6.30 3.88 - 3.8 90 X 50 3450 63.5 - - 95 62 160 99 - 1.8 4 X 1/2 (a) 920N 500 1.50 3.03 3.56 - 2.69 6.69 2.75 3.7 - 100 X 15 3450 38,1 77 90 - 68 170 70 1,8 - X 3/4 (a) 920N 500 1.50 300 3.56 - 2.69 6.69 2.75 3.7 - X 20 3450 38,1 76 90 - 68 170 70 1,8 - 1(a) 500 1.50 2.88 3.56 2.69 69 215 3.6 - X 25 3450 38,1 73 90 - 68 170 70 1.8 - X 11/4 (a) t 920N 500 1.75 3.01 3.78 4.00 2.69 6.69 3.00 4.0 3.6 X 32(b) - 3450 44;5 78 96 102 68 170 76 1,9 1.8 X 11/2 (a) t 920N 500 2.00 328 400 400 29 6.69 325 4.2 3.9 X 40(b) - 3450 50.8 83 102 102 68 170 83 2.0 1,9 X 2(a) t 920N 500 250 324 400 400 269 6.69 388 5.0 4.6 X 50 3450 63.5 82 102 102 68 170 99 2,3 2.1 X 21/2 (a) t 920 500 2.75 3.06 4.00 4.00 2.69 7.25 4.63 5.8 5.0 X 65 3450 69,9 78 102 102 68 184 118 2,6 23 X 76,1 mm 920 -500 2.75 - 4.00 2.69 7.25 463 -64 3450 69,9 - - 102 68 184 118 - 2,9 X 3(a) t 920500 -- 4.50 269T 8.4 64 X 80 3450 88,9 89 114 105 68 1 184 133 3.8 2.9 108.0mm X 11/4 (a) 920N 500 1.75 306 318 - 263 125 3.13 5.0 - X 32 3450 44.5 78 96 - 67 184 80 2.3 - X 1/ (a) 920N 500 2.00 328 4.00 1 263 7.25 38 X 40 3450 50,8 83 102 - 67 184 86 aoie contlnuea on page i. see notes on page 3. Styles 920 and 920N Mechanical-T® Bolted Branch Outlets DIMENSIONS _iwi Styles 920 and 920N w!Grooved Outlet Styles 920 and 920N w/Female Threaded Outlet Max. Dimensions- Inches/millimeters - - Aprx. SIZE Work. Wgt. Each Hole Fern. Run X Branch Press. Dia. Thd. Grv. LbsJk_L........ Fern. Nominal Inches Style PSI +0.13 V V Actual mm No. kPa -0.00 T $ # 4 W Y Z Thd. Grv. 108.0 mm X 2(a) 500 2.50 324 400 - 263 7.25 1 400 5 - X 50 3450 63,5 82 102 - 67 184 102 2,5 - X 21/2 (a) 920 500 2.75 3.06 4.00 - 2.63 7.25 4.41 5.6 - X 65 3450 1 69,9 78 1 102 1 - 67 1 184 112 2,5 - X 3 (a) 920 500 -4.00 63 725 00 65 X 80 3450 8819 - - 1027 184 127 - 3,0 5 X 1V2 (8) t 920 500 2.00 4.06 4.75 4.75 8.38 3.75 7.4 7.6 125 X 40 3450 50,8 103 121 1213 [3.25 213 95 3.4 3.4 X 2(a) t 920 500 50 06 435 47525 838 4.38 8.2 80 X 50 3450 63,5 103 121 1213 213 111 3,7 3,6 X 21/2 (a) t 920 500 2.75 3.81 4.75 4.75 .25 8.38 4.63 8.3 7.9 X 65 3450 69.9 97 121 121 83 213 118 3.8 3.6 X 76,1 mm (a)(b) 920 3450 69,9 97 121 - 83 213 137 - - X 3 (a) t 920 500 3.50 4,00 5.00 4.63 3.25 8.38 5.38 8.4 8.8 X 80 3450 88,9 102 127 118 83 213 137 3.8 4,0 1393mm X 11/2 t 920 500 2.00 4.06 4.75 - 3.25 8.38 3.75 7.4 - X 40 3450 1 50,8 1 103 121 - 83 213 95 3,4 - 2 t 920 500 2.50 4.06 4.75 - 25 838 4.38 83 - X 50 3450 63.5 103 121 1 - 83 213 111 3,7 - X 76,1 mm (a)(b) 920 500 3.50 - - 4.63 325 838 5.38 - 8.8 3450 88,9 - - 118 83 213 137 - 4.0 X 3 920 500 3.50 - - 4.63 325 838 5.38 - 8.8 X 80 3450 8819 - - 118 83 213 137 - 4,0 6 X 11/4 920N 500 1.75 - - 5.13 3.79 9.13 3.25 - 4.8 150 X 32(b) 3450 44.5 - - 130 96 232 83 - 2,2 11/2 (a)t 920N 3450 500 aoo 440 513 5.13 379 913 3.25 5.4 5.1 X 40(b) 50,8 112 130 130 96 232 83 2,4 2,3 X 2(a) t 920N 500 50 &37 3 3 379 913 88 60 56 X 50 3450 63.5 111 130 130 96 232 99 2,7 2,5 X 21/2 (a) t 920 500 2.75 4.19 5.13 5.13 3.69 9.38 4.63 8.3 7.6 X 65 3450 69,9 106 130 130 94 238 118 3.8 3.4 X 76,1 mm (a)(b) 920 500 275 - - 521 69 938 5.38 - 8A 3450 69,9 - - 132 94 238 137 - 3,8 X 3(a) 1 920 - 500 3.50 - 4.50 5.50 3 -3.69 938 X 80 3450 88,9 114 140 130 94 238 137 4,5 3,8 X 4 (a) 1 920 500 4.50 4.50 5.75 5.38 3.69 9.38 6.25 10.1 10.1 X 100 3450 114,3 114 146 137 94 238 159 4,6 4,6 159,0 mm X 11/2 (a) 920N 500 2.00 4.41 513 - 3.63 9.25 3.38 7.8 - X 40 3450 50,8 112 130 - 92 235 86 3,5 - X 2(a) 500 2.50 431 513 - 363 9.25 4.00 8.0 - X 50 3450 63,5 111 130 92 235 102 3,6 - X 21/2 (a) 920 500 275 4.56 5.50 - 3.63 9.25 475 8.6 - X 65 3450 69,9 116 140 92 235 121 3,9 - X 108,0 mm 500 4.50 - - 5.38 363 925 6.25 - 10.0 3450 114,3 - - 137 92 235 159 - 4.5 165,1 mm X 11/2 (a) t 920 500 2.00 4.44 5.13 5.13 3.69 9.38 3.75 7,9 6.9 X 40 3450 50,8 113 130 130 94 238 95 1 3,6 1 3,1 X 2(a) t 920 500 50 4 3 5.13 363 938 4.38 80 7.0 X 50 3450 63,5 113 130 130 92 238 111 3,6 3.2 X 21/2 t 920 500 2.75 4.19 5.13 5.13 3.69 9.38 4.63 8.6 7.6 X 65 3450 69,9 106 130 130 94 238 118 3.9 3,4 X 76.1 mm (a)(b) 920 - 500 T 4.08 T 369 938 538 86 76 3450 69,9 104 130 132 94 238 137 3,9 3,4 X 3(a) t 920 500 3.50 4.50 5.50 5.13 3.69 938 538 10.2 8.4 X 80 3450 88.9 114 140 130 94 238 1 137 4,6 1 3,8 X 4(a) t 920 500 - 9.38 625 84 X 100 3450 114,3 114 146 137 92 238 159 4.8 3,8 8 X 2 (a) 920 500 2.75 5.19 625 - 4.88 12.00 450 11.6 - 200 X 50 3450 69.9 132 159 - 124 305 114 5.3 - X 21/2 (a) t 920 500 2.75 5.19 6.25 6.25 4.88 12.25 4.50 11.6 11.6 X 65 3450 69.9 132 159 159 124 311 114 5,3 5,3 920 500 275 519 625 - 88 0 38 - - X 76.1 mm (a)(b) 3450 69.9 132 159 - 124 305 137 - - X 3(a) t 920 500 3.50 5.50 650 625 4.88 12.001 538 12.6 116 X 80 3450 88.9 140 165 159 124 305 137 5.7 5,3 X 4(a) t 920 500 4.50 531 675 638 488 625 3 5 X 100 3450 114,3 135 171 162 124 305 159 6.9 5,7 bee notes at tell. NOTE: Style 920 and Style 920N housings cannot be mated to achieve cross connections. These new size Style NEW 920N products require a HOLE SIZE different hole size than the Style 920 it replaces, for proper installation. Use caution to assure the proper size hole is prepared for the specific size and style used. Failure to use the proper hole size could result in joint leakage and property damage. NOTES "Center of run to engaged pipe end, female threaded outlet only (Dimen- sions approximate). t Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. # Female threaded outlets are avail- able to NPT and BSPT specifications. British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. For 76,1 mm threaded outlet, spec- ify 2W BSPT clearly on order. Styles 920 and 920N Mechanical-T® Bolted Branch Outlets 11 .02. FLOW DATA Exaggerated for Clarity Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 900N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. OUTLET SIZE Equivalent Length Feet/meter of Pipe Nominal Actual Diameter Out. Dia. Female lnimm In/mm Grooved Threaded 1/2 0.840 - 2.0 15 21,3 - 0,6 3/4 1.050 - 4.0 20 26,7 - 1,2 1 1.315 - 5.0 25 33,7 - 1.5 11/4 1.660 5.5 6.0 32 42.4 1,1 1.8 11/2 1.900 7.0 8.0 40 48.3 2.1 2,4 2 2.375 9.0 10.5 50 60.3 2.7 3,2 21/2 2.875 11.0 12.5 65 73,0 3,4 3,8 3 3.500 13.5 15.5 80 88,9 4,1 4,7 4 4.500 20.0 22.0 100 114,3 6.1 6,7 Cv Values Values for flow of water at +60°F (+16°C) are shown in the table at right. Formulas for CV Values: p=2. cv2 Q = Where: Q = Flow (GPM) /P = Pressure Drop (PSI) Cv = Flow Coefficient Pipe Size Pipe Size Pipe Size Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside Diameter Diameter CV Diameter Diameter CV Diameter Diameter Cv Inches/mm inches/mm Values Inches/mm Inches/mm Values Inches/mm Inches/mm Values 1/2 0.840 17 11/4 1.660 45 2'/2 2.875 135 15 21,3 32 42,4 65 73,0 3/4 1.050 21 11/2 1.900 60 3 3.500 200 20 26,7 40 48.3 80 88,9 1 1.315 25 2 2.375 100 4 4.500 400 25 33,7 50 60,3 100 114.3 APPROVED PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated Working Pressures Run Size PSlIkPa Actual Nominal Outside Diameter Diameter Pipe Inches/mm inches/mm Schedule UL ULC FM 21/2 .6 2.875 - 6.625 1 4 400 400 400 65-150 73,0-168,3 , 2755 2755 2755 21/2 -4 2.875 - 4.500 OF 300 300 300 65-100 73,0-114.3 2065 2065 2065 21/2 .4 2.875 - 4.500 SF 300 300 300 65-100 73.0-114.3 2065 2065 2065 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and conduit corporation. This product shall be manufactured by Victaulic company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Styles 920 and 920N Mechanical-T® Bolted Branch Outlets Attached are page(s) from the 2006 Hilti North American Product Technical Guide. For complete details on this product, including data development, product specifications, general suitability, installation, corrosion, and spacing & edge distance guidelines, please refer to the Technical Guide, or contact Hilti. Hiltl, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com 4.3.9.1 Product Description 4.3.9.2 Material Specifications 4.3.9.3 Technical Data 4.3.9.4 Installation Instructions 4.3.9.5 Ordering Information Listincis/ArDrovals ICC-ES (International Code Council) ESR-1 291 COLA (City of Los Angeles) Research Report No. 25350 Factory Mutual (FM) Pipe Hanger Components for Automatic Sprinkler Systems Mechanical Anchoring Systems :i.i i • rYT "r 4.3.9.1 Product Description The Hilti HDI-P Drop-In anchor is an Guide Specifications internally threaded, flush mounted Expansion Anchor Expansion anchors expansion anchor for solid and shall be flush or shell type and zinc hollow concrete. plated in accordance with ASTM B 633, Product Features Optimized 3/4" anchor length to allow reliable fastenings in hollow core panels, precast plank & post tensioned slabs Shallow drilling enables fast installation Lip provides flush installation, consistent anchor depth and easy rod alignment Setting tool leaves mark on flange when anchor is set properly to enable inspection & verification of proper expansion 4.3.9.2 Material Specifications The HDI-P is manufactured from mild carbon steel, which is zinc plated for corrosion protection in accordance with ASTM B 633, SC 1, Type III SC 1, Type Ill. Anchors shall be Hilti HDI-P anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled with Hilti carbide tipped drill bits. Install anchors in accordance with manufacturer's recommendations. 4.3.9.3 Technical Data HDI-P Specification Table Desc. Length in. (mm) Bit Size' in. Average Ultimate Loads, lb (k Allowable Loads, lb (k 4000 psi Concrete (27.6 MPa) Hollow Core (Spancrete) 4000 psi Concrete (27.6 MPa) Hollow Core (Spancrete) Tension I Shear Tension I Shear Tension I Shear Tension I Shear HDI-P 3/8 3/4(19.1) 1/2 1900(8.5) 3000(13.3) 2100(9.3) 4000 07.8: 380 (1.7) 600(2.7) 420(1.9) 800(3.6) 1 For Hiti matched tolerance carbide tipped drill bits, see section 8.4.1. 4.3.7.4 Installation Instructions T 1. Set depth 2. Hammer-drill 3. Clean hole. 4. Insert anchor. 5. Insert setting 6. Collar of set- gauge on drill, hole, tool and strike ting tool will with hammer leave an until anchor is indentation fully set. on flange of 4.3.9.5 Ordering Information anchor when HOP Anchor properly expanded. wi,, IIU. uwqiuuui DII Uid DOA U15' 283611 HDI-P 3/8 1/2' 100 Setting Tools for HDI-P Anchors Item No. Description 283611 HSD-G 3/8" - 3/4" Setting Tool WI hand guard 253784 HST-P 3/8" - 3/4" Setting Tool 256 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hiltLcom I on espaflol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.ca.hlltl.com I Product Technical Guide 2006 PROFIS: The World's Most Powerful Anchor Design Software Easy to Learn - Start working in just minutes Fast and Powerful - Produce detailed designs quickly Specify with Confidence - The largest number of approvals and latest design codes No charge. Download now 0 www.us.hilti.com Hilti Online Technical Library Design Centers Interactive Product Advisors Full-line Product Catalog Online Ordering Maps to Hilti locations "Contact Us" program to answer your questions Firestop Systems When it comes to Life Safety and building code compliance, Hilti provides complete solutions with a wide range of products and unmatched technical support. Firestop Systems Guides - Through Penetrations - Joint Penetrations FACT Program FS 411 BASIC Training Engineering Judgements Firestop Design Center online © www.us.hilti.com Ml - Industrial Pipe Support Technical Guide A guide to specifying the Hilti modular pipe support system for medium to heavy loads without welding. Ml System is the ideal solution for pipes up to 24 in. diameter Reliable fastenings without welds Easily installed Hilti Diaphragm Deck Design The Hilti Diaphragm Deck Design Program allows designers to quickly and accurately design roof deck and composite floor deck diaphragms. Ability to design with innovative Hilti fasteners for frame and sidelap connection Creates easy to use load tables with span ranges based on user input Allows for different safety factors depending on load type, building code and field quality control Direct link to Hilti website Steel Decking Technical Guide For complete information on Hilti fastening systems for the attachment of steel roof and floor deck, refer to the Hilti Steel Decking Technical Manual. 4 Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I Product Technical Guide 2006 1 Hilti (Canada) Corporation 1-800-3634458 1 www.ca.hilti.com PAYMENT 'TERMS: Net 30 days from date of invoice. Customer agrees to pay all costs incurred by Hilti In collecting delinquent amounts, If any, Including reasonable attorney's fees. FREIGHT: Sales are F.O.B. Destination Point with transportation allowed via Hilt designated mode. Additional charges may apply for expedited delivery, special handling requirements, and order under certain limits. A fuel surcharge may apply depending on market conditions. CREDIT: All orders sold on credit are subject to Credit Department approval. RETURN POLICY: Product may be returned prepaid (unless otherwise authorized) to Hitt! provided: I) it is returned by the original purchaser 10 it is not dated product returned more than 30 days after the original delivery date It is not discontinued, clearance or special order product it is unused, in original packaging and in unbroken quantities. Hilt will inspect product and, if the above requirements are satisfied, will credit to customer the original purchase price. A 15% restocking fee may apply. WARRANTY: Other than the manufacturer's published warranty, no warranties or conditions, express or implied, written or oral, statutory or otherwise are implied. Any and all conditions and warranties implied by law or by the Sale of Goods Act or any similar statutes of any Province are hereby expressly waived, TITLE TO PRODUCT: Title to product remains with Hilt until the total purchase price of product Is paid. PRICES: Customer agrees to pay Hilt prices set out on Invoice. Customer agrees to pay taxes as Indicated on Invoice unless Hilt receives acceptable exemption certificates. INDEMNIFICATION: Customer agrees to use product at own risk and to indemnify Hlitl against all liabilities, including legal fees, to third parties arising out of the use or possession thereof. Hilti shall in no event be liable for special, incidental or consequential damages. CHANGES: Hilt sales personnel are not authorized to modify these Terms and Conditions or modify Customer's credit terms. Terms are subject to change by Hilt with reasonable notice to Customer. CASH SALES: Payment in full is due prior to goods being released. QUOTATIONS: All terms and conditions apply once customer agrees to purchase product. Quotations on special promotion products are only valid until end of promotion period. In The United Sates PAYMENT TERMS: Net 30 days from date of invoice. Customer agrees to pay all costs Incurred by Hilti in collecting delinquent amounts, if any, Including reasonable attorney's fees. FREIGHT: All sales are F.O.B. Destination with transportation allowed via Hilti designated mode. Additional charges may apply for expedited shipments, special handling requirements, and orders below certain dollar amounts. A fuel surcharge may apply depending on market conditions. CREDIT: All orders sold on credit are subject to Credit Department approval RETURN POLICY: Products must be in saleable condition to qualify for return. Saleable condition is defined as those unused Items in original packaging and in unbroken quantities. All returns are subject to Hilti Inspection and acceptance, and a 15% restocking charge. Proof of purchase Is required for all returned materials. Special orders and discontinued Items are not eligible for return credit. Dated materials are not returnable 30 days beyond date of invoice. WARRANTY: Hilt warrants that for a period of 12 months from the date it sails a product it will, at its sole option and discretion, refund the purchase price of, repair, or replace such product If it contains a defect in material or workmanship. Absence of Hilti's receipt of a written notification of such a defect within this 12-month period shall constitute a waiver of all claims with regard to such product. The warranty time periods for certain products are limited by the warranty period in the literature that accompanies these products. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hilti shall In no event be liable for, and Customer hereby agrees to indemnify Hilt[ against all claims related to, special, direct, indirect, consequential, or any damages arising out of or related to the sale, use, or inability to use the product. ACCEPTANCE OF ORDER: Acceptance Is limited to the express terms contained herein, and terms are subject to change by Hilti with reasonable notice to Customer. Additional or different terms proposed by Customer are deemed material and are objected to and rejected, but such rejections shall not operate as a rejection of the offer unless it contains variances in the terms of the description, quantity, price or delivery schedule of the goods. DOMESTIC ORIGIN: Any non-domestic Hilt product will be so identified on shipping documents and Invoices for federal government customers. All other customers may obtain such information by written request for Hilt, Inc., Contract Compliance. P.O. Box 21148, Tulsa, Oklahoma 74121. Hilt sales personnel are not authorized to warrant the country of origin of Hilt products. BUSINESS SIZE: Hlitl Is large business. PRICES: Prices are those stated on the order. Hlitl does not maintain most favored customer records, makes no representation with respect to some, and rejects any price warranty terms proposed by Customer. Hit l's published net price list Is subject to change without notice. CONSENT TO JURISDICTION: All transactions made pursuant hereto shall be deemed to have been made and entered into In Tulsa, Oklahoma. Any and all disputes arising directly or indirectly from such transactions shall be resolved in the courts of the County of Tulsa, State of Oklahoma, to the exclusion of any other court, and any resulting judgment may be enforced by any court having jurisdiction of such an action. All transactions shall be governed by and construed in accordance with the laws of the State of Oklahoma. INDEMNIFICATION: Customer hereby agrees to indemnify Hilt for any coats, including attorney's fees, incurred by Hilti as a result, in whole or in part, of any violation by Customer of any Federal, State or Local statute or regulation, or of any nationally accepted standard. It shall be Customers sole responsibility to comply with all applicable laws and regulations regarding the handling, use, transportation, or disposal of products upon taking possession of same. AUTHORIZATION: HiLTI SALES REPRESENTATIVES ARE NOT AUTHORIZED TO MODIFY THESE TERMS AND CONDITIONS, WARRANT SPECIFIC APPLICATIONS, OR EXECUTE CUSTOMER DOCUMENTS. Hilti, Inc. (US) 1-800-879-8000 j www.us.hilti.com I Product Technical Guide 2006 1 Hilti (Canada) Corporation 1-800-363-4458 1 www.ca.hilti.com 5 Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number H'111 Fig. 99 - All Thread Rod Cut to Length Fig. 100 -All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1'/4 8000 7140 360 11/2 11630 10370 510 OflicelManufactunng Facility .1315 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.toIcocom 61 Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/211 thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4° thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mu. Galvanized. For Stainless Steel materi- als, order TOLCOTm Fig. 200WON. Order By - Figure number and pipe size 2 .112.:ThRU 8 INCH PIPE Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/ 2/ 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 3/ 2/ 400 12 1/4 3/8 8mm or 10mm 32/4 21/8 400 13 1/2 3/8 8mm or 10mm 31/a 2 /a 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/s 414 600 27 3 3/8 10mm Vs 4 600 29 31/2 3/8 10mm 7/ 51/4 600 34 4 3/8 10mm 73/s 5 1000 35 5 1/2 12mm 9'4 6'i4 1250 66 6 1/2 12mm 101/9 6/4 1250 73 8 1/2 12mm 131/8 8/4 1250 136 OlficelManufacturing Facility .1315 Sampson Ave.. Corona, CA 92879 • Ph: 951.731.5599 • Fax: 951.731.0330 Customer Service • 800.786.5266 www.folco.com