Loading...
HomeMy WebLinkAbout5935 DARWIN CT; ; FA070037City of Carlsbad Fire Alarm Permit Permit No: FA070037 Job Address: 5935 DARWIN CT Permit Type: FALARM Parcel No: 2121201500 Lot #: 0 Reference No.: Status: ISSUED Applied 3/13/2007 Approved: 3/14/2007 Issued: 3/14/2007 PC #: Inspector: Project Title:' REEF MONITORING SYSTEM PLAN CHECK & INSPECTION Applicant: SONITROL 8921 COMPLEX DR SDCA 858-505-3000 Owner: 5935 DARWIN COURT LLC 12770 HIGH BLUFF DR #270 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 117 0 117 0 REEF SAN94066 5935 DARWIN COURT CARLSBAD, CALIFORNIA 92008 FIRE SPRINKLER MONITORING SYSTEM SUBMITTAL CONTENTS System Description NAC Power Supply Requirements Circuit & Device Schedule Battery Calculations NAC Voltage Drop Calculations Wire Chart List of Material Catalog Sheets/CSFM Sheets Drawings APPROVED AS$UBMITTED hl XV&l IRLP CARLSBAD RRE EPARTMEN1 -T- ILL COPY Sonitrol of San Diego 8921 Complex Drive San Diego, CA 92123 Phone: (858) 505-3000 Fax: (858) 688-4410 FA0 4m3l- REEF CARLSBAD, CALIFORNIA FIRE SPRINKLER MONITORING SYSTEM SYSTEM DESCRIPTION An addressable fire alarm system will be provided at the above referenced location. The fire alarm control panel will be a (Fire-Lite MS-9200UD). The fire alarm control panel will be located in the open office area by the riser, with a remote annunciator located at the main entrance to the building. A smoke detector will be located above the FACP, with a double action manual pull station located at the main enterance, the panel will also monitor 13 duct smoke detectors on 13 A/C units provided by others. A horn/strobe will be provided at a constantly attended location. Each initiating device is assigned a discrete address and custom message, identifying each device for an alarm, trouble, or supervisory condition. System indications are generally as follows: A. Activation of any alarm initiating device shall cause the following; Activate horn/strobe at main entrance. Annunciate audibly and visually at the fire alarm control panel and remote annunciator the device initiating the alarm condition. Activate an alarm condition via the internal dialer to the remote station monitoring service. If alarm activation is from a waterfiow switch, the system shall send a separate and distinct waterflow signal to the remote station monitoring service. B. A system trouble condition shall cause the following; Annunciate audibly and visually at the fire alarm control panel as a trouble condition. Activate a trouble condition via the internal dialer to the remote station monitoring service. C. A supervisory condition, such as a tamper switch alarm, shall cause the following; Annunciate audibly and visually at the fire alarm control panel as a supervisory condition. Activate a supervisory condition via the internal dialer to the remote station monitoring service. D. Activation of a duct smoke detector shall cause the following; Will not activate the horn/strobe at the main entrance (unless otherwise directed by the FD). Annunciate audibly and visually at the fire alarm control panel and remote annunciator the device initiating the supervisory condition. Activate an supervisory condition via the internal dialer to the remote station monitoring service (unless otherwise directed by the FD). AHU shutdown and duct smoke detector by others. REEF CARLSBAD, CALIFORNIA FIRE SPRINKLER MONITORING SYSTEM LIST OF MATERIAL February 20, 2007 QUANTITY MODEL # DESCRIPTION Fire Alarm Control Panel - Firelite I MS-9200UD Addressable FACP with Walibox and Door and Built-In Digital Communicator(Holds up to 18AH) 2 PS-12250 Batteries, 12V, 25AH 1 BB-26 Battery Box 1 CHG-75 Battery Charger Remote Annunciator -Sonitrol/Firelite 1 SON-LCD-80F Remote LCD Annunciator (Replaces the LCD-40) Multi-Candela Wall Mount Horn/Strobes - Wheelock 1 NS-24-MCW-FR Horn/Strobe, selected to ll0cd, Red Manual Pull Stations -Sonitrol/Firelite 1 SON-BG-12LX Double Action Manual Pull Station Photoelectric Smoke Detectors - Firelite 1 AD-355 Addressable Smoke Detector (Includes B350LP Base) Monitor Modules - Firelite 15 MMF-300 Addressable Monitor Module Wire 1 Lot per NEC#760 REEF CARLSBAD, CALIFORNIA FIRE SPRINKLER MONITORING SYSTEM POWER SUPPLY REQUIREMENTS - HORN/STROBES FACP: NOTE: MAXIMUM CURRENT AVAILABLE FROM A MS9200UD IS 6.OA. HORN/STROBE CIRCUIT 1 SPARE SPARE SPARE O.244A O.000A O.000A O.000A O.244A NAC CIRCUITS HORN/STROBE CIRCUITS: 1 - Maint Entrance 2— spare 3 - spare 4 - spare REEF CARLSBAD, CALIFORNIA FIRE SPRiNKLER MONITORING SYSTEM CIRCUIT & DEVICE SCHEDULE - PAGE 1 ADDRESS DEVICE MESSAGE ACTION DETECTORS: up to 20 P01 AD-355 Above FACP A REEF CARLSBAD, CALIFORNIA FIRE SPRINKLER MONITORING SYSTEM CIRCUIT & DEVICE SCHEDULE - PAGE 2 ADDRESS DEVICE MESSAGE ACTION MODULES: up to 20 MO1 MIvIF-300 MON Waterfiow Switch 11T FLR A M02 MMF-300 MON Tamper Switch 1ST FLR C M03 MMF-300 MON Duct Smoke Detector HPi 1ST FLR D M04 MMF-300 MON Duct Smoke Detector 1HP-2 1ST FLR D M05 MMF-300 MON Duct Smoke Detector 1HP3 1ST FLR D M06 MMF-300 MON Duct Smoke Detector 1HP-5 1ST FLR D M07 MW-300 MON Duct Smoke Detector HP-22 1ST FLR D M08 MMF-300 MON Duct Smoke Detector HP-12 1ST FLR D M09 MMF-300 MON Duct Smoke Detector HP-il 1ST FLR D MO 10 MMF-300 MON Duct Smoke Detector HP- 10 1ST FLR D moil MMF-300 MON Duct Smoke Detector HP-20 1ST FLR D M012 SON-BG12LX Pull at main entrance 1ST FLR A M06 MIvIF-300 MON Duct Smoke Detector HP-31 2m FLR D M07 MMF-300 MON Duct Smoke Detector HP-32 2ND FLR D M08 MW-300 MON Duct Smoke Detector FIP-29 2' FLR D M09 MMF-300 MON Duct Smoke Detector HP-27 2ND FLR D Note: The letter under the "action" refers to items that are implemented should that device go into an alarm condition. Any additional set points that are not uniform for that action are listed after the letter. All letter actions listed here correspond to the actions listed with the system description at the beginning of this submittal. QUANTIT MODEL# I MS9200 I NS24 NS24 NS24 NS24 ASWP RSS RSS RSS 75/180 I SON-LCD80F I SON-BG12LX SD355 D350P H355 CRF300 CMF300 15 MMF300 B5OIBH I AD355 Maximum Alarm I Current (See Table 7.3) DSM SM BATTERY CALCULATIONS FACP PROJECT: REEF STANDBY STANDBY ALARM ALARM CURRENT EXTENSION CURRENT EXTENSION 0.255 0.255 0.325 0.325 110 0 0 0.244 0.244 75 0 0 0.184 0 30 0 0 0.107 0 15 0 0 0.074 0 0 0 0.128 0 75 0 0 0.109 0 30 0 0 0.063 0 15 0 0 0.041. 0 0 0 0.025 0.025 0.064 0.064 0 0 0.00023 0.00023 0 0.0003 0 0 0.0003 0 0 0.0003 0 0 0.00027 0 0 0.00039 0 0 0.0004 0.006 0 0.001 0 0 0.00036 0.00036 0 0 0 0 0 0 0 0 0.4 0.4 0 0 0 0 0 0 0.035 0 0.035 0 0.028 0 0.028 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HOURLY STANDBY CURRENT 0.28659 ALARM DRAW 1.033 HOURS STANDBY 60 HOURS ALARM 0.084 TOTAL STANDBY CURRENT 17.1954 TOTAL ALARM 0.086772 25AH BATTERY PROVIDED TOTAL STANDBY 17.1954 TOTAL CURRENT 17.28217 20% DERATING 3.456434 BATTERY NEEDED 20.73861 A kA NAC Voltaç p Calculator for Audio I Visual devices This calculator provided voltage drop calculations in three formats (Point to Point, End of Line, and Load Centering). Make sure that you know what method is accepted by, and the results do not exceed the limits set by the respective jurisdiction I I I I Point to Point Method End of Line Method Load Centering Method Project Name REEF CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS Date I Circuit Number 1 Totals Voltage Totals Voltage Totals Voltage Area Covered Main Entrance Current Distance Drop Current Distance Drop Current Distance Drop Nominal System Voltagel 24 0.244 1 525 1.25 0.244 525 1.253 0.244 525 0.626 Minimum Device Voltage 16 End of Line Voltage 22.75 End of Line Voltage 22.75 End of Line Voltage 23.37 Total Circuit Current 0.244 Wire Ohm's Percent Dropj 5.22% Percent Dropj 5.22% Percent Dropj 2.61% I Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source Distance from source to 1st device 525 16 4.89 Standard Wire Resistance in Ohms per 1000 feet. Wire Gauge for balance of circuit 16 4.89 I 18=7.771 16=4.891 14=3.071 12=1.981 10=1.241 Enter current in amps. Distance _ ________ 18-14 Awg = Solid Conductors 12-10 Awg = Stranded Conductors .150 = 150 ma from Voltage Notes: I I I I I I Device Device previous At Drop from Percent Wire resistance is doubled in the calculations for two wires (Positive and Negative) Number Current device Device source Drop The voltage calculated to the last device in any method must not be lower then I Device 1 0.244 525 22.75 1.253 5.22% the manufactures listed minimum operating voltage (IE: rated operating voltage 20-32 VDC. END 22.75 1.253 5.22% I T- 22.75 .253 _1 5.22% END Device Manufacturer Wheelock Device Manufacturer Wheelock ND 22.75 .253 _1 5.22% I Current @Rated Voltage I Current ©Rated Voltage ND 22.75 1.253 5.22% Horn Strobes Strobe Only ND 22.75 1.253 5.22% Model # Candela Model # Candela ND 22.75 1.253 5.22% NS-24MCW-FR 110 0.244 ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% _______ ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% ND 22.75 1.253 5.22% END - 22.75 1.253 5.22% END 22.75 1.253 5.22% Totals 0.244 525 End of Line Voltage 22.75 40% CONDUIT FILL CALCULATION: 1" Riser into FACP = 1" EMT Maximum number of 16/2 conductors that can be used in 1" EMT with 40% fill (16/2 is worst case scenario): 1" EMT = .346 square inches per Table 4 Chapter 9 16/2 FPLP =.02461 square inches per manufacturer (Part #4511) 346 square inches /.02461 square inches per conductor = 14 conductors maximum Our 1" riser into the FACP shall have 4 conductors (one 18/2 SLC, one 16/2 NAC, one 18/2 annunciator network, and one 18/2 annunciator power). 3/4" stub up to device(s) = 3/4" EMT Maximum number of 16/2 conductors that can be used in 3/4" EMT with 40% fill (16/2 is worst case): 3/4" EMT =.213 square inches per Table 4 Chapter 9 16/2 FPLP =.02461 square inches per manufacturer (Part #4511) .213 square inches /.02461 square inches per conductor = 8 conductors maximum Our 3/4" stub up's will have a maximum of 4 conductors at the main entrance (one 18/2 SLC, one 16/2 NAC, one 18/2 annunciator network, and one 18/2 annunciator power). (2) Fire tlTeeAtarms by Honeywell GENERAL The Flre•Lite MS-9200UD is a compact, cost-effective, intelli- gent addressable fire alarm control panel with a capacity of 198 addressable Fire-Lite devices on one Signaling Line Circuit (SLC) and a built-in modem for remote site upload/download or remote monitoring. The Signaling Line Circuit (SLC) loop supports up to 99 address- able detectors including photoelectric, photoelectric with heat, ionization, photoelectric duct, fixed heat, fixed heat with rate-of- rise, and fixed high-heat detectors. It also supports up to 99 ad- dressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), control (for Notification Appli- ance Circuits), and relay (two Form-C) modules. The panel uses surface-mount technology and is designed for ease of installa- tion, programming, and maintenance. It features the latest in ad- vanced fire protection technology, including maintenance alert and automatic detector test functions. SPECIAL FEA TURES: Built-in modem. Selectable strobe synchronization per NA C. Remote site upload/download. Four Class B or two Class A NAC circuits. FEATURES SLC Loop: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices (99 detectors and 99 monitor, control, or relay modules), including the new ad- dressable dual-monitor module, heat detectors, and duct de- tector. SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG (3.25 mm2). Requires twisted, shielded wire (3,000 ft./914.4 m un- twisted, unshielded wire). Notification Appliance Circuits (NACs): Four onboard NACs with additional NAG capability using output control modules (CMF-300 or CMF-300-6). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 6.0 amps total NAC power with optional XRM-24. Advanced Fire Technology: Sensitivity testing with printable results, onsite or offsite. Automatic drift compensation. Programming and Software: Autoprogram (learn mode) reduces installation time. Fully programmable from local keypad, local PS-2 keyboard or PC via PK-Plus Windows® utility. Remote site upload/download capability. Two-level user-programmable passwords. September 29, 2005 DF-52293 • Al -250 MS-9200UD Intelligent Addressable FACP with Built-In Modem Section: Addressable ® E M EA 7165-0075:208 341-03-E LISTED APPROVED Custom English labels (per point) maybe manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. User Interface: Built-in modem (DACT). Remote Acknowledge, Silence, Reset and Drill via addressable monitor modules, ACS Series annunciators or LCD-80F remote annunciator. EIA-232 printer/PC interface (variable baud rate) on main cir- cuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings ad- justments. History file with 1,000-event capacity. ElA-485 supporting up to 32 ACS Series annunciators. EIA-485 supporting up to 32 LCD-80F annunciators. Maintenance alert warns when smoke detector dust accumu- lation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. cont'd pg. 3 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific IS09 applications or anticipate all requirements. All specifications are subject to - change without notice. 1=11=11 i u=6 For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, INGINFERING I MANOFAC1UBING Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS Made in the U.S.A. DF-52293 • 09/29/05 - Page 1 of 4 24 VOC EIA -485 INTERFACE (four wires and optional fifth Earth Ground wire) LCD-80F Up to 6,000 ft. (1825.8 ni) between each LCD-80F in the EIA-485 loop, and between each LCD-80F and the FACP 24 VDC __ ri ri -in ACS mode wires) _I i: _ MCI ci _l LJ MCA lam i _________ I I3 MCI IJ ANNUNCIATORS' AFM-LED, LDM, ACS/ACM EIA -232 INTERFACE (PlM-24) built into the motherboard 41 - ftl 4RI l* I MS-9200L1D ADDRESSABII flRE AlARM COPlOL PANEL U... .— U... - Optional REVERSE POLARITY! CITY BOX - - - OUTPUT 444444 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8RF) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES - L) SMOKE DETECTORS S0355, SD355T, CP355 HEAT DETECTORS H355, H355R [c*i DUCT DETECTORS 0350PL, D35ORPL MONITOR MMF-300, MDF-300, MMF-302, CMF-300. CRF-300. 1300 NOTE: System can use either the printer OR the LCD-80F. They cannot be used simultaneously. WIRING REQUIREMENTS The SLC requires use of a specific wire type to ensure proper circuit opera- tion. It is recommended that all SLC wiring be twisted-pair shielded to mini- mize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. Wire Requirements Distance in Feet (m) Typical Wire Size Twisted-pair, shielded 10,000 feet 12 AWG (3.1 mm2): Belden 9583, Genesis 4410, (3,048 m) Signal 98230, WPW 0999. Twisted-pair, shielded 8,000 feet 14 AWG (2.00 mm2): Belden 9581, Genesis 4408, (2,438 m) Signal 98430, WPW D995. Twisted-pair, shielded 4,875 feet 16 AWG (1.3 mm2): Belden 9575, Genesis 4406 (1,486 m) and 4606, Signal 98630, WPW D991. Twisted-pair, shielded 3,225 feet 18 AWG (0.78 mm2): Belden 9574, Genesis 4402 (983 m) and 4602, Signal 98300, WPW D975. Unwisted, unshielded 3,000 feet (915 12— 18 AWG (3.1 - 0.78 mm2). l'1''4'1'llWi Page 2 of 4 - DF-52293 • 09/29/05 MINI MONITOR MMF-301 ADDRESSABLE MULTI-MODULES MMF-300-10, MMF-302-6, CMF-300-6, CRF-300-6 PULL STATION BG-12LX 52293dE ,vnf Point trouble identification. Local piezo sounder. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). Optional 4XTMF module (conventional reverse polarity/city box transmitter). CONTROLS AND INDICATORS LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE/PRESIGNAL (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) MEMBRANE SWITCH CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 5-16. 12-key pad with full alphabet 17-20. 4 cursor keys 21. ENTER FIELD-PROGRAMMING FEATURES OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order pro- gramming kit PK-CD, containing PK-Plus, separately. Requires PRT/PK cable). Upload/download system programming locally to the MS-9200UD in less than one minute. AUTOPROGRAMMING: Command the MS-9200UD to pràgram itself (takes less than 30 seconds). In the Auto-Program mode, the MS.9200UD scans for all possible devices at all addresses, stores the device types, and addresses found, and then loads default values for all options (General Alarm). It also checks for two or more devices set to the same address. ONLINE EDIT., While still providing fire protection, the MS-9200UD may be programmed from the front panel. Simple menu trees dis- played on the LCD allow the trained user to perform all functions without referring back to the programming manual. ENGLISH LABEL LIBRARY: Quickly select labels from a stan- dard library of more than 50 adjectives/nouns, such as "FLR 3 HALLWAY," or enter custom labels letter-by-letter. Use recall function to repeat previously used label. PROGRAM CHECK: Automatically catch common errors, such as control modules not linked to any zone or input point. MAINTENANCE ALERT The MS-9200UD continuously monitors each smoke detector and is capable of reporting maintenance conditions. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more information. AUTOMATIC TEST OPERATION The MS-9200UD performs an automatic test of each detector every two hours. Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trouble. NFPA STANDARDS The MS-9200UD complies with the following NFPA 72 Fire Alarm Systems requirements: LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). REMOTE STATION (Automatic, Manual and Waterflow) (re- quires 4XTMF). PROPRIETARY (Automatic, Manual and Waterflow). CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). SPECIFICATIONS AC Power-TB1: 120 VAC, 60 Hz, 3.0 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery (lead-acid only) - TB2: Maximum charging circuit: Normal flat charge 27.6 VDC @ 0.80 A. Maximum battery charger capacity: 18 AH. MS-9200UD cabinet holds maximum of two 18 AH batteries. For 25-120 AH batteries, use the CHG-1 20F or CHG-75 Battery Charger and BB-55F Battery Box. NOTE:. Jumper JP3, on the FACP main circuit board, must be cut to disable the FACP battery charger when using the CHG- 120F. Remote Synchronization Output - TB2: A 24 VDC, 40 mA signal that mimics the sync signal of NAC 1 and can be utilized by remote power supplies such as the FCPS-24FS6/8. This allows NAC devices attached to the power supply to synchronize with the devices connected to NAG 1 of the FACP. Communication Loop - (standard) TBS: 24 VDC nominal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, shielded pair length. Maximum loop current 400 mA (short cir- cuit) or 100 mA (normal). Maximum loop resistance: 40 ohms. Supervised and power-limited. Notification Appliance Circuits - TB4: Power-limited circuitry. Maximum voltage drop in wiring: 2.0 VDC. Nominal operating voltage: 24 VDC. Current limit: fuseless, electronic, power-lim- ited circuitry. Maximum signaling current per circuit: 2.50 A. End- of-line resistor: 4.71K ohm, 1/2 watt (P/N 71252 UL listed) for NAGs. Refer to Fire-Lite Device Compatibility Document for listed com- patible devices. Programmable and Trouble Output Relays - TBS, TB6, TB7: Contact rating: 2.0 A © 30 VDC (resistive), 0.5 A © 30 VAC (re- sistive). Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) - TB1, Terminals 3 (+) & 4 (-): Maximum ripple volt- age: 10 mVRMS. Up to 0.5 A for powering four-wire smoke detec- tors. Power-limited circuit. Refer to Fire'Lite Device Compatibil- ity Document for listed compatible devices. Nonresettable Power #1(24 VDC Nominal) -TB1, Termi- nals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMs. Up to 0.5 A total DC current available from each output. Power-limited cir- cuit. TB1, Terminals 1 (+) & 2 (-) can be configured as resettable 24 V or non-resettable via JP4. NOTE: If using optional XRM-24, total NAC and auxiliary cur- rent draw cannot exceed 6 A. EIA-485 (ACS) - TB6: ACS annunciator connector, Terminal 1 (+) and Terminal 2 (-). EIA-485 (TERM) - TB7: Terminal mode annunciator connector, Terminal 1 (Out +), 2 (In i-), 3 (Out -), 4 (In -). EIA-232-T88: PC/printer connector, Terminal 1 (Transmit), 2 (Receive), 3 (DTR), 4 (Ground). CABINET SPECIFICATIONS Door: 18.67" (47.43 cm) high x 15.78" (40.08 cm) wide x 1.08" (2.74 cm) deep. Backbox: 18.50" (47.0 cm) high x 15.50' (39.37 cm) wide x 4.37" (11.1 cm) deep. Trim Ring (FC-TR): 21.62" (54.92 cm) high x 18.62" (47.3 cm) wide. DF-52293 • 09/29/05 - Page 3 of 4 PRODUCT LINE INFORMATION MS-9200UD: 198-point addressable Fire Alarm Control Panel. Includes 80-character LCD display, single printed circuit board, and cabinet. ACM-BRF: Optional plug-in relay module provides 8 Form-C 5.0 amp relays. PK-CD: Contains PK-Plus programming software for Windows®- based PC computer (cable not included). DP-9200UD: Dress panel forMS-9200UD. FC-TR: Trim Ring for semi-flush mounting. BB-55F: Battery box, required to house two BAT-1 2260 batteries and one CHG-1 20F battery charger. Forbatteries greater than 26 Al-I, consult factory for housing/mounting arrangements. BB-26: Battery backbox, holds upto two BAT-1 2260 batteries. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 25 to 120 AH. CHG- 120ForCHG-75 required for charging greater than 25AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG- 120ForCHG-75 required forcharging greater than 25 AH batteries. BAT-11 2180: Battery, 12 volt, 18.0 AH, (two required) BAT-1 2260: Battery, 12 volt, 26 AH, (two required; requires CHG- 75). BAT-1 2550: Battery, 12 volt, 55 AH, (two required; requires CHG- 75). PRT/PK-CABLE: Cable printer/personal computer interface cable. Windows® is a registered trademark of Microsoft Corporation. COMPATIBLE ADDRESSABLE DEVICES Al! feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- riseoption. AD355: Low-profile, intelligent, "Adapt" multisensor detector (B350LP base included). D350PL: Photoelectric low-flow duct smoke detector. D350RPL: Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0(10.16 cm) box. Includes plastic coverplate and end-of-line resistor. Module maybe configured for either a Style B (Class B) or Style D (Class A) lOG MDF-300: Dual Monitor Module. Same as MMF-300except it provides two Style B (Class B) onlylDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similarto MMF-300, but may monitor upto20conventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. CM F-300: Addressable Control Moduleforone Style Y/Z (Class B/ A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16cm) electrical box. Notification Appliance Circuit option requiresextemal 24 VDC to powernotif cation appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDlswitch. Mounts directly to a 4.0(10.16cm) box, surface mount using the SMBSOO. BG-i 2LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 7 operation). SMB500: Used to mount all modules exceptthe MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one ortwo modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS- 6 chassis in a BB-6F. MMF-302-6: Six-zone interface module. Mount one ortwo modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS- 6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a 1313-217 cabinet (optional). Mount upto six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. NOTES: 1) Compatible with legacy Fire-Lite 300 Series devices. Please consult factory for further information on all the previous 300 series devices: CP300/CP350, 5D300(T)/SD350(T), D350P/ D350RP, M300, M301, M302, C304, and BG- IOLX. 2)'A " suffix should be included only when ordering ULC listed units (e.g., SD350A, MMF-300A). 3) For more information on Compatible Addressable Devices for use with the MS-9200UD, see the fol- lowing data sheets (document numbers): AD355 (DF-52386), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF- 52374), CMF/CRF Series (DF-52 130), CP355 (DF-52383), D350PUD35ORPL (DF-52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 Series/MDF-300 (DF-52 121), MMF- 300-10 (DF-52347), MMF-302-6 (DF-52356), 5D355/SD355T (DF-52384). COMPATIBLE ANNUNCIATORS EIA-485 interface: Built into the motherboard. ACS/ACM Annunciator Series: Allows annunciation of loop modules and detectors. ACM-BRF: provides eight Form-C mappable relays with relay-by- zone capability for elevator recall, HVAC control, etc. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-char- acter, backlit LCD-type fire annunciators capable of displaying English-language text. Up to 32 LCD-80F annunciators may be connected to the EIA-485 terminal mode serial interface on the MS-9200UD motherboard. AFM-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. 16 or 32 with expandable (AFM-X Series) and non-expandable (AFM Series) configurations. NOTE: For more information on Compatible Annunciators for use with the MS-9200UD, see the following data sheets (docu- ment numbers), ACM-BRF (DF-5 1555), A CS/A CM Series (DF- 523 78), LDM Series (DF-51384), LCD-80F (DF-52 185). AGENCY LISTINGS AND APPROVALS See the first page of this data sheet for listing agencies and file numbers. These listings and approvals apply to the basic MS9200UD control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. Page 4 of 4 - DF-52293 • 09/29/05 (2) FIre•LITe arms www.firelite.com GENERAL The CHG-75 battery charger is designed to charge lead- acid batteries that provide emergency standby power for a Fire Alarm Control Panel (FACP) and related equipment. Two 12-volt batteries are used in series to supply a nomi- nal 24 VDC. The battery charger is compatible with any FACP that uses lead-acid batteries with a rating of 25 AH (amp-hours) to 75 AH. The FACP must have a feature that allows the disabling of the control panel battery charger. FEATURES 120 VAC or 220/240 VAC operation. Rated for batteries 25 to 75 AH. Charger can connect to the Signaling Line Circuit (SLC) of a Fire-Lite intelligent control panel (e.g., MS-9200, MS- 9600, and MS-9200UD) for trouble monitoring. Mounts in a BB-26, BB-55F, MS-9600 or MS-9200 en- closure. Screw terminal connections for battery, battery backup to other equipment and SLC loop. 6.25 A fuse (Fl) for AC overload protection. 15.0 A replaceable fuse (F2) provides battery with cur- rent-limiting, short circuit, and overload protection. 15.0 A replaceable fuse (F3) provides battery with cur- rent-limiting and overload protection for output to con- nected equipment. Form-C trouble relay rated for 2.0 A @ 30 VDC (resis- tive). Ground fault detection circuit (can be disabled). Battery, charger, and AC voltage supervision. AC loss reporting delay option for 8- or 16-hour delay. Connectors for trouble input and output - direct CHG- 75 troubles to FACP and allow daisy-chaining of exter- nal troubles through the charger without affecting charger operation. Master trouble input allows monitoring of another de- vice or zone. Connectors for optional AM-11 .ammeter and VM-1 volt- meter. Diagnostic LEDs for monitoring: Primary AC On, Charger Trouble, Ground Fault, Charging, SLC Communication, Low Battery. CONSTRUCTION AND OPERATION The CHG-75 consists of a PC board and mounting chas- sis. Aside from mounting options (see Installation), the only options involved in ordering the CHG-75 are the choice of an AM-1 Ammeter or a VM-1 Voltmeter. September 20, 2004 DF-52220 0-250 CHG-75 Battery Charger Section: Power Supplies/Accessories - czj California U1 M EA (d) State Fire Marshal 297-01-E 7315-0075:201 LISTED S1287 .. - lt : ":-' .••'' ;, 0 ••' :r CHG-75 fW S Charging current is provided automatically when the bat- tery voltage falls below the charger's output voltage. While charging the batteries, the CHGING (charging) LED will turn on. When batteries are fully charged, the charger maintains a float charge of 27.6 VDC. The SLC LED and AC LED are the only other LEDs that should be on during normal operation if SLC communication is programmed at the FACP and the SLC enable switch is On. APPLICATIONS Use the CHG-75 with Fire-Lite MS-9200 or MS-9600 when batteries required for standby are rated equal to or greater than 25 AH. AVYiON! When installing the batteries, make certain that proper polarity is observed between the power leads and the battery terminal posts. Fire-Lite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep IS09001 our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, ENGINEERING & MANUFACTURING Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS Made in the U.S.A. DF-52220 09/20/04 - Page 1 at 3 + CHG-75 SPECIFICATIONS Primary AC power in (TBI): 120 VAC, 60 Hz, 2.0 A; or 220/ 240 VAC, 50 Hz, 1.0 A. Wire size: minimum 14 AWG (2.0 mm') with 600-volt insulation. Form-C relay (T134): 2.0 A at 30 VDC (resistive). Float charge voltage: 27.6 VDC. Maximum charging current: 4.5, A (peak). Battery sizes: 25 AH to 75 AH. INSTALLATION The CHG-75 has a variety of mounting options. It can be mounted in either the FACP (MS-9200, MS-9600), or re- motely in the BB-26 or BB-55F battery backbox. Install the CHG-75 within 20 feet (6.096 m) of the main FACP. When mounting in a FACP: The CHG-75 can be mounted in the bottom of the MS-9600 backbox, using the self-tap- ping screws included with the charger. In a similar fash- ion, the supplied nuts can be used to mount the charger to pem studs located in the bottom of the MS-9200 backbox. A separate battery box must be used to house the batter- ies when employing these configurations. When mounting remotely in the BB-55F: The CHG-75 mounts to the right of the AM-1/VM-1 mounting holes posi- tioned at the top of the cabinet. Use the supplied self-tap- ping screws to secure the charger to the backbox. When mounting remotely in the BB-26: The CHG-75 mounts just below the AM-1/VM-1 mounting holes posi- tioned at the top center of the cabinet. Use the supplied nuts to mount the charger to pem studs located in the backbox. Meter configurations/installation: Order the AM-1 (amme- ter) and/or the VM-1 (voltmeter) when either option is re- quired and the charger is mounted in the BB-26 or BB-55F battery backbox. PANEL BATTERY CHG-75 BOARD CONNECTION nt.. VM-i voltmeter can be installed on the CHG-75 to provide a visual indication of the battery/charger voltage. When the battery is disconnected, the voltmeter mea- sures charger voltage only. The VM-1 can mount into a mounting slot on the front of the BB-26 or BB-55F battery box. AM-1 ammeter can be installed on the CHG-75 to provide a visual indication of the charger current. The AM-1 can mount into a mounting slot on the front of the BB-26 or BB-55F battery box. AGENCY LISTINGS AND APPROVALS The CHG-75 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 1481 Power Supplies for Fire Alarm Systems. See the first page of this data sheet for listing agencies and file numbers. These listings and approvals apply to the CHG-75. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. PRODUCT LINE INFORMATION CHG-75: battery charger circuit board and mounting chas- sis. Includes mounting hardware and installation instruc- tions. BAT-12260: 26 AH, 12-volt, sealed lead-acid battery. BB-26: battery backbox - holds up to two BAT-12260 26 AH batteries. Box dimensions: 15.6" (39.62 cm) wide x 15.5" (39.37 cm) high x 5.125" (13.02 cm) deep. Door dimensions: same dimensions as backbox. BB-55F: battery backbox - holds up to two BAT-12550 55 AH batteries. Box dimensions: 24.0" (61.0 cm) wide x 14.0" (35.6 cm) high x 7.75" (19.7 cm) deep. Door dimensions: 24.125" (61.3 cm) wide x 14.25" (36.2 cm) high x (door adds 0.063" [approx. 0.16 cm] to depth). AM-I: ammeter, 0-10 amps, for CHG-75 mounted in BB-26 or BB-55F. VM-I: voltmeter, 0-50 volts, for CHG-75 mounted in BB-26 Page 2 of 2 - DF-52220 • 09120/04 UNDERWRITERS LABORATORIES INC. MULTIPLE LISTING CORRELATION SHEET ML File No. S6662 Issued: 1 2003-04-02 Revised: MULTIPLE LISTING of CONTROL UNIT ACCESSORIES, SYSTEM (UROXX) for 712230002 1 Sonitrol Corp. Basically Listed for 1 407739002 1 Notifier Basically listed products covered by Procedure and/or Reports under File No. S635_______ Basic Applicant's Products (Supplier's) Multiple Listee's Covered Vol. Product Designation Product Designation Remote 18 FDU-80 Son-LCD-80F annunciator Marking: Same as that described in Follow-Up Service Procedure and/or Report except for Multiple Listee's name, ML tradenaine, when applicable, and product designation. IC: 850 BRITAIN, 025 W NEW ENGLAND April 15, 2003 SON-52185 4W _SONITROL GENERAL The SON-LCD80F is a compact, cost-effective, 80-char- acter, backlit LCD remote Fire Annunciator for use with the Sonitrol 198 and Sonitrol 636 FACPs (Fire Alarm Control Panels). The SON-LCD80F displays complete system point status information and includes control switches for remote control of critical system functions. Up to 32 SON-LCD80Fs may be connected onto the EIA- 485 terminal port (T1317) of each control panel. The SON- LCD80F requires no programming, which saves time dur- ing system commissioning. FEATURES 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Si- lence, Drill, and Reset with enable key. System status LEDs for Power, Alarm, Trouble Supervi- sory, and Alarm Silenced. No programming necessary - SON-LCD80F connects to the terminal port (T1317) on the FACP. Displays device-type identifiers; individual point alarm, trouble, or supervisory; zone and custom alpha labels. Time-and-date display field. Aesthetically pleasing design. May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). Up to 32 SON-LCD80F annunciators per FACP. Plug-in terminal blocks for ease of installation and ser- vice. Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. Local piezo sounder with alarm and trouble resound. Semi-flush mounts to 2.188" (5.556 cm) minimum deep, three-gang electrical box (Fire-Lite P/N 10103) or three- gangable electrical switchbox. Surface-mounts to Fire-Lite SBB-3 surface backbox. OPERATION The SON-LCD80F annunciator provides the FACP with point annunciation with full display text on an 80-character LCD display. The SON-LCD80F also provides an array of LEDs to indicate system status, and includes control switches for remote control of critical system functions. The SON-LCD80F provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations SON-LCD8OF 80-Character Liquid Crystal Display Remote Fire Annunciator for use with the Sonitrol 198 and Sonitrol 636 LISTED S6662 FIRE:ALARM ANNUNCIATOR.. , • :. SOHITROL CORPORATION &i SYSTEMS ALL NORMAL 11:06P e32003 teni Ce) 1H - SON-LCDBOF S52185C1.mI sofldrolbw.jpg on the SON-LCD80F use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communications (two in and two return); and two for the 24 VDC regulated power. Dip switches control local functions such as: piezo disable, control switches/key-switch disable, transmit/receive mode. INSTALLATION The SON-LCD80F can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box (Fire-Lite P/N 10103) or three-gangable electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ___________ All specifications are subject to change without notice. Sonitrol Corporation wwwsonitrol.com — Made in the PRODUCT LINE INFORMATION MOUNTING TO BACKBOX(ES) SON-LCD80F 80-character, backlit, LCD Fire Annunciator SON-LCD80F annunciators can be semi-flush mounted in with control switches for remote control of system a three-gang electrical box with a minimum depth of 2.188" functions, and key-switch lock. (5.556 cm) (Fire-Lite PIN 10103). 10103 Three-gang electrical box, minimum 2.188' (5.556 SON-LCD80F annunciators can be mounted in three- cm) deep, for semi-flush-mount applications. gangable electrical switchboxes connected together. SBB-3 Three-gang surface backbox for surface-mount NOTE: Alternately, SON-LCD80F annunciators can be applications, mounted to the SBB-3 surface backbox for surface-mount applications. Electrical Installer's Note: This annunciator may not fit easily into a standard 3-gang electrical box if locking clamps are used to secure wiring entering the rear or side knock- outs. Only use the TOP or BOTTOM knockouts to bring wiring into a standard 3-gang electrical box. Page 2 of 2 - SON-51285 . 04/15/03 W SONITROL GENERAL The SON-BGI2LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for the addressable Sonitrol 198 and Sonitrol 636 fire alarm control panels. Because the SON-BG12LX is ad- dressable, the control panel can display the exact loca- tion of the activated manual pull station. This leads fire service personnel quickly to the location of the alarm. FEATURES Aesthetically pleasing, highly visible, dual-action design. Meets ADA 5 lb. maximum pull force. Easily operated (dual-action). Attractive shape and textured finish. Mounts, semi-flush, to a standard single-gang (2.125' [5.398 cm] minimum depth), double-gang, or 4.0" (10.16 cm) square electrical box. When the handle latches in down position, the word "ACTIVATED" appears at the top of the handle in bright yellow to clearly indicate the station has been operated. Key/lock reset; needs only a 1/4-turn to lock/unlock. Includes Braille text on station handle. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm' wire). Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. . Maintenance personnel can open station (for inspection and testing) without causing an alarm condition. Built-in LED, which is visible through the handle of the station, flashes red in normal operation and latches on steady red when in alarm. CONSTRUCTION Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automatically resets the switch. April 15, 2003 SON-52013 SON-BG1 2LX Addressable Manual Pull Station Patented, U.S. Patent No. D428,351; 6,380,846 U.S. Patent Pending: 091686,286 LISTED S6662 Manual stations connect with two wires to one of the con- trol panel SLC loops. Each manual station, on command from the control panel, sends data to the panel represent- ing the state of the pull station switch. Two rotary decimal switches allow address settings (01-99). PRODUCT LINE INFORMATION SON-BG12LX Dual-action addressable pull station. Includes key lock/reset feature, and screw terminal connections. SB-10 Surface backbox. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Sonitrol Corporation www.sonitrol.com SON-52013 . 04/15/03 - Page 1 of 2 INSTALLATION The SON-BG12LX can be semi-flush mounted into a single-gang, double-gang, or standard 4.0" (10.16 cm) square electrical outlet box, or surface mounted to the Model SB-10 surface backbox. lithe SON-BG12LX is semi- flush mounted, then the Optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mount- ing with 4.0" (10.16 cm) or double-gang boxes. (not with single-gang boxes). ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Average operating current (LED flash): 300 mA. Temperature range: 32°F - 120°F (0°C to 49°C). Relative humidity range: 10% - 93% non-condensing. Maximum SLC loop current: 300 pA. ARCHITECTURAL! ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- operated reset lock in order that they may be tested and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions pro- vided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10; or semi-flush mounting on a standard single-gang, double-gang, or 4.0" (10.16 cm) square electrical box, and shall be installed within the lim- its defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. 0 ADDRESS 0 02 0 v0o 87 87 .4 TERMINAL CONNECTIONS 1 SLC (—) 2 SLC (+) Back of station without door. I rL ELD ROTARY DECIMAL SWITCHES Cover open to show easy access to monitor module, rotary switch, and UL label. Page 2012 — 5011-52013 . 04/15/03 July 14, 2004 DF-52386 . E-810 Fire-LIWALarms www.firelite.com The Fire-Lite Alarms AD355 Adapt detector is an intelli- gent, addressable, multi-sensing, low-profile detector de- signed for use with the Fire-Lite MS-9200, MS-9200U0 and MS-9600 Fire Alarm Control Panels (FACPs). The Adapt detector combines photoelectric and thermal sensing technologies designed to increase immunity to false alarms. Unlike traditional intelligent detectors, the Adapt detector has a microprocessor in the detector head that processes alarm data. As a result, the Adapt detector can adjust its sensitivity automatically without operator inter- vention. The Adapt detector is ideal in office complexes, schools, college campuses, manufacturing and industrial facilities, or anywhere else the use of a particular area may change. One day a conference room, tomorrow a kitchen, the next a copy machine room - the Adapt detector automatically adjusts its sensitivity to its environment! FEATURES Automatically adjusts sensitivity levels without the need for operator intervention or programming. Sensitivity in- creases with heat. Combination photo and thermal technology. Microprocessor-based technology. MS-9200, MS-9200U0 and MS-9600 compatible. Sleek, low-profile design. Rotary, decimal addressing (01 - 159 on MS-9600, 01 - 99 on MS-9200 and MS-9200UD). Addresses can be viewed and changed without the need for electronic programmers. Dual LED design provides 360° viewing angle. Several base options, including relay, isolator, and sounder. Built-in functional test switch activated by external mag- net. Listed to UL 268. SPECIFICATIONS Operating voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 250 pA @ 24 VDC (without communication); 360 pA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24 VDC ('ON'). AD355 (A) 'Adopt" Multi-Sensor Low-Profile Intelligent Detectors Section: Addressable Devices - California State Fire Marshal 7272-0075.203 LISTED MEA FM 243-02-E APPROVED 8937pho1Jpg AD355 ADAPT Loop resistance: 40 ohms maximum; varies according to control panel used. Refer to manuals (document numbers) for the MS-9600 (51335), MS-9200UD (51906), and MS- 9200 (51003). Operating humidity range: 10% - 93% non-condensing. Operating temperature range: 0°C to 38°C (32°F to 100°F). Air velocity rating: 0 to 4,000 ft/mm (20.32 m/sec). Height: 2.1" (5.33 cm). Diameter: 6.1" in B35OLP base. Weight: 5.2 oz. (147 g). Thermal sensor: 135°F (57° C) fixed. INSTALLATION The Adapt plug-in detector uses a separate base to sim- plify installation, service and maintenance. A special tool (XR-2) allows maintenance personnel to plug in and re- move detectors without using a ladder. Mount base on a box at least 1.5' (3.81 cm) deep. Suitable mounting base boxes include: 4.0" (10.16 cm) square box. 3.5' (8.89 cm) or 4.0" (10.16 cm) octagonal box. ° Single-gang box (except relay or isolator base). Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product IS09001 information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. I I For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northferd, Connecticut 06472. FNNIE1If I MANUMCWII? Phone: (800) 627-3473, Toll-Free FAX: (577) 699-4105. QUALITY SYSTEMS DF-52386 •07/14/04 - Page 1 of 2 PRODUCT LINE INFORMATION NOTE: suffix indicates ULC-Listed model. A0355 Low-profile, intelligent, multi-sensor detec- tor (B350LP base included. A0355A Same as above with ULC Listing (B350LPA base included). Available Bases: 8350LP(A) Plug-in detector base (included). Dimen- sions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plastic ring, 4.0" (10.16 cm) octagonal box, 3.5(8.89cm) octagonal box, or single-gang box. All mount- ing boxes have a minimum depth of 1.5 (3.81 cm). 8501 BH(A) Standard European 4.0" (10.16 cm)flangeless base, with sounder. B5O1BHT(A)Same as B50113H(A), but includes temporal sounder. B224RB(A) Plug-in System Sensor relay detector base. Diameter: 6.2° (15.75 cm). Mounting: 4.0' (10.16 cm) square box with or without plastic ring. 4.0° (10.16 cm) octagonal box, or 3.5' (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5' (3.81 cm). B22481(A) Intelligent isolator base. Isolates SLC from shorts on the loop. Accessories: RA400Z(A) Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. For use with B501(A) and B35OLP(A) bases only. SMK400 Surface mounting kit provides for entry of surface wiring conduit. For use with 8501(A) base only. RMK400 Recessed mounting kit. Foruse with B501(A) base only. M02-04-00 Test magnet. XR-2 Detector removal tool. Allows installation and/ or removal of detector heads from bases in high ceiling applications. XP-4 Extension pole for XR-2. Comes in three 5-ft. (1.524 m) sections. Pao 2 of 2 - DF-52386 07114/04 July 14, 2004 DF-52121 E-325 FIreLlTe ALarms www.firelife.com GENERAL Four different monitor modules are available for Fire-Lite Alarms MS-9200, MS-9200UD and MS-9600 intelligent fire alarm control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 (Replaces M300) -The MMF-300 Moni- tor Module is a standard-sized module (typically mounts to a 4" [101.6 mm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input de- vices. MMF-301 (Replaces M301)—The MMF-301 is a Min- iature Monitor Module (a mere 1.3" (33.02 mm) H x 2.75" (69.85 mm) W x 0.5' (12.70 mm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the MMF-301 to be mounted in a single-gang box behind the device it is monitoring. MMF-302 (Replaces M302) - The MMF-302 Inter- face Module is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 (New) - The MDF-300 Dual Monitor Module is a standard-sized module (typically mounts to a 4" [101.6 mm] square box) that supervises two Class B (Style B) cir- cuits of dry-contact input devices. MMF-300 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No' additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade 01 - 99 (MS-9200 and MS-9200U0) and 01-159 (MS-9600) entry of address. LED flashes red during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire Class A or Class B fault-tolerant Initiating Device Circuit (IDC) for normally- open-contact fire alarm and supervisory devices. The MMF- 300 can be used to replace M300 modules in existing sys- tems. MMF-300 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class D) Initiating MMF-300(A) Series/MDF-300 Addressable Monitor Modules Section: Addressable Devices California State Fire .a~~ Marshal ì!OV i 7300-0075:185,, LC APPROVED LISTED CSXO'X 0 ~ A. 31 1p MDF-300 Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style 0 circuit. Maximum IDC resistance is 1,500 ohms. MMF-300 Operation - Each MMF-300 uses one of 99 (MS-9200 and MS-9200UD) or 159 (MS-9600) avail- able module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 400 pA (LED flashing). EOL resistance: 47K ohms.. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (1016 mm) square x 2.125" (53.975 mm) deep box. FireLite® Alarms is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product IS09001 information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. I 1=1.1 For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. 110110110 & MANUMMIING Phone: (800) 627-3473. Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS - Paae 1 0f3 MML301 MINI MONITOR MODULE Built-in type identification automatically identifies this device as a monitor module to the MS-9200. MS- 9200UD or MS-9600. Powered directly by two-wire SLC Loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address (01-99 for MS-92001MS- 9200UD, 01-159 for MS-9600). The MMF-301 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301 is intended for use in intelli- gent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-con- tact fire alarm and security devices. The MMF-301 can be used to replace M301 module in existing systems. 14i.k,Q1 I_ADDRESS 01 13/,- \\2 II 1O65 cam 11 v/-))) PA 4 LOOP I 76 TENS ONES MMF.301 Applications - Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterilow devices, or other normally-open dry-contact devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301 Operation - Each MMF-301 uses one of 159 available module addresses on an SLC loop MS- 9600. It uses one of 99 on a MS-9200 or MS-9200UD. It responds to regular polls from the control panel and re- ports its type and the status (open/normal/short) of its Ini- tiating Device Circuit (IDC). MMF-301 Specifications Nominal operating voltage: 15 to 32 VDC. Average operating current: 375 pA maximum. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C) Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (33.02 mm) high x 2.75" (69.85 mm) wide x 0.5" (12.70 mm) deep. Wire length: 6" (152.4 mm) minimum. MMF-302 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source (resettable). High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01-99 for MS-9200/MS- 9200UD, 01-159 for MS-9600). LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intel- ligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and moni- tor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conven- tional detectors back to the control panel. All two-wire de- tectors being monitored must be UL compatible with the module. MMF-302 Applications - Use the MMF-302 to moni- tor a zone of two-wire smoke detectors. The monitored cir- cuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 Operation - Each MMF-302 uses one of 159 available module addresses on a MS-9600 SLC loop. It uses one of 99 on a MS-9200 or MS-9200UD. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Requires regulated, resettable 24 VDC power. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. MDF-300 DUAL MONITOR MODULE Built-in type identification automatically identifies this de- vice as two monitor modules to the control panel. Powered directly by the two-wire SLC loop. No addi- tional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01 - 159 on the MS-9600, 01-99 for MS-9200/MS-9200UD). LED flashes red during normal operation and latches on steady red to indicate alarm. Page 2 of 3 - DF-52121 .07(14/04 The M[)F-300 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independant two-wire fault-toler- ant Initiating Device Circuits (lDCs) at two separate, con- secutive addresses. It is capable of monitoring normally open-contact fire alarm and supervisory devices, or either normally open or normally closed devices for non-fire ap- plications. MOF-300 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull sta- tions, waterflow devices, or other normally-open dry-con- tact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms. MDF-300 Operation - Each MDF-300 uses two of 99 (MS-9200 or MS-9200UD) or 159 (MS-9600) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in com- munication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MDF-300 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (114.3 mm) high x4' (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125' (53.975 mm) deep box. Accessories: SM8500 electrical box. INSTALLATION MMF-300, MMF-302 and MDF-300 modules mount di- rectly to a standard 4". (101.6 mm) square, 2.125" (53.975 mm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordi- nances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard elec- trical box. All wiring must conform to applicable local codes, ordinances and regulation. ARCHITETS'/ENGI NEERS' SPECIFICATIONS Specifications of these and all Fire-Lite Alarms products are available from Fire-Lite Alarms. PRODUCT LINE INFORMATION MMF-300 Monitor Module. MMF-300(A) Monitor Module (Canada). MMF-301 Mini Monitor Module. MMF-301(A) Mini Monitor Module (Canada). MMF-302 Two-Wire Detector Monitor Module. MMF-302(A) Two-Wire Detector Monitor Module (Canada). MDF-300 Dual Monitor Module. SM BSOO Optional Surface-Mount Backbox. MOUNTING DIAGRAM for standard-sized modules DF-52121 07114/04 - Page 30(3 00 COOPER Wheelock Series NS Horn Strobes and Series NH Horns Series NS Description: The Series NS Horn Strobe Appliances are designed for indoor, wall and ceiling mount applications. The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA. Strobe options include 1575cd or the Wheelock patented Multi-Candela strobe with field selectable candela settings of 15/30/75/110cd for wall mount and 15/30175195cd and 115/177cd for ceiling mount. These versatile Horn Strobe Appliances can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supply with the Wheelock patented Sync Protocol. Additionally, the audible may be silenced while maintaining strobe activation. All models of the Series NS and NH are designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA72/ANSI 117.1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements concerning photosensitive epilepsy. The Wheelock patented 2-Wire Series NS Horn Strobes and Series NH Horns offer more features with lower current draw than competitors. NS and NH Ceiling Mount Appliances will be available July 2006. MA . APPROVED E5946 151-92-E 7125-0785:142 55391 Series NH Features: Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model number in Specifications and Ordering Information ADA/NFPAIUFC/ANSI compliant Complies with OSHA 29, Part 1910.165 Wall mount model Field Selectable Candela Setting 15/30/75/110cd (24 VDC Multi-Candela models) or 1575cd in 12 or 24 VDC Ceiling mount model Field Selectable Candela Setting 15/30/75195cd and 115/177cd (24 VDC Multi-Candela models) Selectable Continuous Horn or Temporal (Code 3) 2 Selectable dBA settings of 90 and 95 dBA in both tones Patented Universal Mounting Plate 12 and 24 VDC models with UL 'Regulated Voltage" using filtered DC or unfiltered VRMS input voltage Wall and Ceiling Mount Ceiling models with same look as Wheelock round ceiling strobes and speakers NH horn is selectable 12 or 24 VDC in 1 appliance The strobes can be synchronized using the Wheelock sync modules or power supplies with built in Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #I8AWG wires NOTE: All CAUTIONS and WARNINGS are Identified by the symbol A. All warnings are printed In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Sees NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to Identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL Standard 1971 Model Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (CD) NS-24MCW 24 16.0-33.0 15/30/75/110 NS-241575W 24 16.0--33.0 15 (75 On Axis) NS-121575W 12 8.0-17.5 15 (75 on Axis) NS-24MCC 24 16.0-33.0 15/30/75/95 NS-24MCCH 24 16.0-33;0 115/177 Table 2: dBA Ratings for Series NSINH Horn Reverberant dBA Anechoic dBA @1 Oft per UL464 @lOft Description Volume 12 24 12 24 VDC VDC VDC VDC Continuous High 83 87 89 95 Low 76 81 84 90 Horn Code 3 High 79 82 89 95 Horn Low 72 76 84 90 Table 3: UL Max Current* Series NSINH Audible Wall Mount Strobe Models Ceiling Mount Strobe Models NH-12124 NS-241575W 24 VDC NS-24MCW NS-24MCC NS-24MCCH @24VDC 15175cd 15cdI30cd75cdk10cd 15cd30cdl75cd95cd 115cdk77cd High (95) dBA 24VDC 0.044 0.104 0.074 0.107 0.184 0.244 0.082 0.124 0.209 0.275 0.350 0.477 Low (90) dBA 24VDC 0.018 0.096 0.0660.1010.177 0.232 0.071 0.1140.201I 0.261 0.306 0.429 Series NSINH I2VDC Audible Wall Mount * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NH-12124 AudlStrobe @12V NS-121575W High (89) dBA 12 VDC 0.021 0.220 Low (84) dBA I2VDC 0.012 0.210 Wiring Diagrams' I NS/NH APPLIANCE FROM ___ _______ TO NEXT PRECEDING _____ APPLIANCE APPLIANCE, SM/DSM OR EOLR PS-1 2124-8MP, PS-1 2124-8CP OR --tJ'-12i FACP - SIGNAL NS AND NH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE FEATURE SM F + STROBE Strobe - STROBE A NAC NH C crcu LI3D +A NS udible EOLR - Audible Audible NAG Circuit NS AND NH APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE DUAL SYNC MODULE ØSYNC OSYNC OUTI -1 AIN1 MINUSI F AUDIBLE A IDNAL ' C P IIII IT AN - AUDIBLE P .-OUT2 JN2 APPLIANCE ALIAE MINUS2 BIG lIAL CIRCUIT RETURN NOTE: NS!NH must be set on Code 3 horn tone to achieve synchronized temporal (Code 3) tone. Refer to installation instruction (P83983, P83600 respectively). For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for P5.12/24.8MP SPECIFICATION & ORDERING INFORMATION Model Number Order Code Strobe Candela Sync WI SM, DSM or PS-24-8MC 24 VDC 12 VDC Mounting Options# Agency Approvals UL MEA CSFM FM BFP NS-24MCW-FR 9404 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-24MCW-FW 9405 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-241575W-FR 7806 15(75onAxis) X X - B,D,EF,G,H,J,N,O,R,X X X X X X NS-241575W-FW 7811 15(75 (in Axis) X X - B,D,EF,G,H,J,NO,R,X X X X X X NS-121575W-FR 7816 15(75onAxis) X - X B,D,E,F,G,H,J,N,O,R,X X X X X X NS-121575W-FW 7818 15(75onAxis) X - X BD,EF,G,H,J,N,OR,X X X X X X NH-12/24-R 7449 - X X X B,DE,F,G,HJN,O,R,X X X X X X NH-12/24-W 7500 - X X X B,DE,F,GH,J,NO,R,X X X X X X NS.24MCC.FR 3754 15/30/75/95 X X - E X * * )( * NS-24MCC-FW 3753 15/30/75/95 X X - £ X * * X * NS-24MCCH-FR 3756 115/177 X X - E X * X * NS-24MCCI-1-FW 3755 115/177 X X - E X * * X * NH-12/24R-R 3752 - X - X B,D,E,F,G,H,J,N,O,R,X X * * X * NH-12/24R-W 3751 - X - X B,D,E,F,GH,J,NOR,X X * * X * NS and NH Ceiling Mount Appliances will be available July 2006. *pending Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance With Wheelock Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS The audible/visual notification appliances shall be Wheelock Series NS Horn Strobe appliances and Series NH Horn appliances or approved equals. The Series NS appliances shall meet and be listed for UL Standard 1971(Emergency Devices for the Hearing- rnpaired for Indoor Fire Protection Service). The Series NH Horn shall be UL Listed under Standard 464 (Fire Protective Signaling). 'he horn strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible 'ith standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels (90 and 95 dBA) and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series NS shall be of low current design. Where wall mount, Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/110 candela. Where ceiling mount, Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/95 candela or 115/177 candela. The selector switch for selecting the candela setting shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with the Wheelock SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobes shall revert to a non-synchronized flash- rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS Horn Strobes and NH horn shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. 3 Branchport Avenue ng Branch, NJ 07740 me: (800) 631-2148 (732) 222-2588 Www.cooperwheelock.com WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S2100 NS/NH 09/06 September 29, 1999 D-500 FirelfferAL.arams PS Series Batteries Section: Power Supplies/Accessories GENERAL Power-Sonic PS Series batteries provide secondary power for the Swhole series of Flre'Lite fire alarm control panels. FEATURES MH14328 (S) Provide secondary power for control panels. Gelled electrolyte. Sealed and maintenance-free. Overcharge protected. Extended shelf life. Easy handling with leakproof construction. Ruggedly constructed, high-impact ABS plastic case. Long service life. Compact design. CAPACITY Battery capacity, expressed in ampere-hours (AH), is the product of a discharge current and the length of time that the current is dis- charged. Batteries are rated according to their performance during 20 hours of discharge at a constant current. The rated capacity of a battery is determined by subjecting it to a constant discharge current for 20 hours at 68°F (200C). After 20 hours the voltage across the terminals is measured. The discharge current which causes a reading of 1.72 volts per cell (5.16 V on a 6 V battery and 10.32 V on a 12 V battery) is called the rated current. This current multiplied by 20 is the rated capacity of the battery. APPLICATIONS Use the PS Series batteries to provide backup power for control panels. Select batteries based on current requirements for your system and the capacity of its charger. These batteries can be used over a temperature range of -76°F to +140°F (-60°C to +600C). CONSTRUCTION The sealed construction of the Power-Sonic battery allows trouble- free, safe operation in any position. There is no need to add elec- trolyte, as gases generated during overcharge are recombined in a unique "Oxygen Cycle." The battery is sealed, leakproof, and main- tenance-free. The case is made of ABS, a high-impact plastic resin (acrylonitrile butadiene styrene copolymer) with high resistance to chemicals and flammability. INSTALLATION Al! panels have space reserved for batteries. See the appropriate panel installation manual for battery size restrictions. Typical inter- connection diagrams are shown in the literature accompanying each control panel. SEALED RECHARGEABLE BATTERY aT1DN1ILI &!5sONIr Model P5.695 6 Volt 9.5 AH Power-Sonic Corporation The PS-695 Battery This document is not intended to be used for installation purposes. We try to keep our prod- uct information up-to-date and accurate. We cannot cover all specific applications or antici. ISO9001 pate all requirements. All specifications are subject to change without notice. For more Engineering and Manufacturing information, contact Fire Lite. Phone: (203) 484-7161 FAX: (203) 484.7118 Qualify System Certified to Flre•LITe'ALarrns One Fire-Lite Place, Northford, Connecticut 06472 International Standard ISO-9001 DF-50970 - Page 1 013 TOP VIEW E C HEIGHT 1 BELOW 3.70 ± 0.08 inches (94 ± 2 mm) HEIGHT 2 BELOW 3.86 10.08 inches (96 ± 2 mm) II I BB-17F: Optional Battery Backbox 14-1/2° W x 8-1/4° H x 4-3/4° D 2 (mm: 368.3 W x 209.55 H x 120.65 D) For remote mounting of two 12-volt P5-12180 batteries. 11 2.56 ± 0.04 inches (65 ± 1 mm) llogdirnljif BB-55F: Optional Battery Backbox See CHG-120F catalog sheet for details. ENGINEERING SPECIFICATIONS The fire control panel shall be equipped with secondary power provided by gelled-electrolyte batteries. The batteries shall be maintenance-free and shall be capable of powering the system in a manner and for a length of time determined by the governing regulations and the authority having jurisdiction. MODEL Nominal Voltage V Nominal Capacity @ 20 hr. rate A.H. Discharge Current 0 20 hr. rate mA DIMENSIONS Width Depth Height Height over terminal Weight In. mm. in. mm. in. mm. in. mm. lbs. kg. PS-695 6 9.5 475 4.26 108 2.75 70 5.54 141 5.54 141 4.9 2.2 PS-1250 12 5.0 250 3.54 90 2.76 70 4.02 102 1 4.21 107 4.1 1.9 PS-1270 12 7.0 325 5.94 151 2.56 65 3.70 94 3.86 98 5.7 2.6 PS42120 12 12 600 5.94 151 3.86 98 3.70 94 3.86 98 8.8 4.0 PS42180 12 18 875 7.13 181 2.99 76 6.57 167 6.57 167 12.8 58 PS-12250 12 25 1300 6.89 175 6.54 166 4.92 125 4.92 125 18.7 8.5 PS42600 12 60 3000 10.25 260 6.60 168 8.20 208 9.45 240 39.7 18.0 PS-121000 12 100 5000 12.00 305 6.60 168 8.20 208 9.45 240 65.7 29.8 S I uuiu,iIiIw. IIII1IIII1I!ii1 III1uI'IuuIuII ': •u i iu•rn 0% -20° -10° 0° 10° 20° 30° 40° 50° 60° I109grf2.wsd Temperature (Degrees C.) I- SEALED RECHARGEABLE BATTERY MODEL PS-1270 12 VOLT 7.0 AMP. HOUR 5.94 ± 0.04 inches (151±1mm) 100% 80% ii of 60% 40% 20% 1 2 3 5 10 2030 60 2 3 5 10 20 30 IO9f1.uf minutes hours Discharge Time 0 20°C (68°F) Page 2 of 3 - DF-50970 120% Effect of Temperature on Capacity NONE N P5-121000 RECHARGEABLE BATTERY: APPLICATIONS AND CHARGING CYCLE APPLICATIONS: Limit initial current to 20A. Charge until battery voltage (undercharge) reaches 14.40 to 14.70 volts at 68°F (200C). Hold at 14.40 to 14.70 volts until current drops to approximately 1000 mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "FLOAT" OR "STAND-BY" SERVICE: Hold battery across constant voltage source or 13.50 to 13.80 volts continu- ously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged position. NOTE: Due to the self-discharge characteristics of this type of battery, it is imperative that the battery be charged after six to nine months of storage, otherwise permanent loss of capacity might result from sulfation. 100% 90% 0 80% ly 60% Gn C.) Ca roi .JJIO Co C-) 40% 0% Charging is NOT II necessary unless II 100% of capacity is required. Charging before 1 r - use is necessary to help recover - full capacity. A Charge may 11 fail to restore II full capacity. 40°C 30°C - 20°C (104°F) (86°F) - (68°F) II DO NOT JL let batteries - reach this state. 14.0 V 13.0 V 12.0 V CO 11.0 V Ca C 10.0 V 9.0V 8.OV 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) - ___ I • _____ _oft - on 01 111 0 1oilIIiI'!! __IIIIU20111L!i1uI__I ___•li1h1YNII Ull U 12 2.4 6 12 24 36481 2 4 6 810 20 40 MINUTES X HOURS Discharge Time PS-121000 Shelf-Life and Storage PS-121000 Discharge Characteristics DF-50970 - Page 3ol3 (ienesis Cable Systems Iage I ot 2 Honeywell HoneywII.co.it - ACS - HOME ABOUT US PRODUCTS RESOURCES FEEDBACK LITERATURE CENTER TRAINING CONTACT US FAQ ARTICLE 760 Fire Alarm Systenis Jacketed Cables Unshielded, Plenum Rated Applications: Wiring of Fire protective signalling circuits. Code Restrictions: 01< for use with all power limited circuits. Features: Available in 5001t or 1000ft Tangle-Free Boxes or Spools. Sequential Footage Markings. Construction: Copper Conductors, Genelene Insulation, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red, Conductor Color: Chart 4. Fire Alarm Jacketed Unshielded, Plenum Rated 75CC Im To view an Adobe Acrobat PDF specification, click on the PDF symbol beside the part number. AWG No. Sol Diameter Nom. Cap. Listings Avg. Wt. / Mft Part No Cond. pt/Ft 22 4 Solid .122 22 UL, FPLP/CL2P, C(UL), F16 15 (Lbs.) 4501 22 6 Solid .144 22 UL, FPLP/CL2P, C(UL), FT6 21 (Lbs.) 4502 22 8 Solid .156 22 UL, FPLP/CL2P, C(UL), FT6 28 (Lbs.) 4503 22 1.0 Solid .182 22 UL, FPLP/CL2P, C(UL), FT6 33 (Lbs.) 4504 22 12 Solid .188 22 UL, FPLP/CL2P, C(UL), FT6 38 (Lbs.) 4505 18 2 Solid .134 24 UL, FPLP/CL2P, C(UL), FT6 19 (Lbs.) 4506 :18 4 Solid .156 24 UL, FPLP/CL2P, C(UL), F16 32 (Lbs.) 4507 18 6 Solid .192 24 UL, FPLP/CL2P, C(UL), FT6 45 (Lbs.) 4508 18 8 Solid .208 24 UL, FPLP/CL2P, C(UL), FT6 58 (Lbs.) 4509 18 10 Solid .244 24 UL, FPLP/CL2P, C(UL), FT6 74 (Lbs.) 4510 16 2 Solid .154 27 UL, FPLP/CL2P, C(UL), FT6 26 (Lbs.) 4511 16 4 Solid .180 27 UL, FPLP/CL2P, C(UL), FT6 47 (Lbs.) 4512 14 2 Solid .182 27 UL, FPLP/CL2P, C(UL), FT6 38 (Lbs.) 4513 .14 4 Solid .214 27 UL, FPLP/CL2P, C(UL), FT6 68 (Lbs.) 4514 :12 2 Solid .214 30 UL, FPLP/CL2P, C(UL), FT6 55 (Lbs.) 4515 Spools Only "Consult Factory for Availability h+,..I/mw cl'l p,m/rrrrliipttpii,n1atp 9 ppr71fl iSli 1 7I7fl1?flfl Genesis Cable Systems Page 1 of 2 Honeywell 4I-1cjiwi1' 4A:.T - HOME ABOUT US PRODUCTS RESOURCES FEEDI3ACK LITERATURE CENTER TRAINING CONTACT US FAQ ARTICLE 760 Fire Alarm Systems Jacketed Cables Shielded, Plenum Rated Applications: Wiring of Fire protective signalling circuits. Code Restrictions: OK for use with all power limited circuits Features: Available in 5001t or 1000ft Tangle-Free Boxes or Spools. Sequential Footage Markings. Construction: Copper Conductors, Low Smoke PVC Insulation, Alu Mill um/Mylar Shield with Drain Wire. Low Smoke PVC Jacket. Standard Jacket Color: Red. Conductor Color: Chart 4. Fire Alarm Jacketed Shielded (overall shield) Plenum Rated 75°C To view an Adobe Acrobat PDF specification, click on the PDF symbol beside the part number. AWG No. Sol Diameter Nom. Cap. Listings Avg. Wt. / Mft Part No Cond. pf/Ft 22 4 Solid .126 47 UL, FPLP/CL2P, C(UL), FT6 18 (Lbs.) 4601 18 2 Solid .134 51 UL, FPLP/CL2P, C(UL), FT6 22 (Lbs.) 4602 18 4 Solid .160 51 UL, FPLP/CL2P, C(UL), FT6 35 (Lbs.) 4603 18 6 Solid .196 51 UL, FPLP/CL2P, C(UL), FT6 50 (Lbs.) 4604 18 8 Solid .212 51 UL, FPLP/CL2P, C(UL), FT6 62 (Lbs.) 4605 16 2 Solid .158 59 UL,. FPLP/CL2P, C(UL), FT6 35 (Lbs.) 4606 16 4 Solid .186 59 UL, FPLP/CL2P, C(UL), FT6 52 (Lbs.) 4607 14 2 Solid .186 60 UL, FPLP/CL2P, C(UL), FT6 44 (Lbs.) 4608 14 4 Solid. .218 60 UL, FPLP/CL2P, C(UL), FT6 75 (Lbs.) 4609 12 2 Solid .218 67 UL, FPLP/CL2P, C(UL), FT6 63 (Lbs.) 4610 -I- Spools Only - - For Tec:hnical assistance call: Toll Free 800.222.0060 ,,,, /ri.r,-li ir.tbr,,ri1 '?P n,.=1Afl '7 1 ')/')fll')flfl