HomeMy WebLinkAbout1937 DOVE LN; ; AS03022210/8/2020 AS030222 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS030222
Job Address: 1937 DOVE LN Status: ISSUED
Permit Type: SPRINK Applied 10/28/2003
Parcel No: 2150521500 Approved: 1/14/2004
Lot #: .0
Reference No.: Issued: 1/14/2004
PC #: Inspector:
Project Title: LA COSTA GREENS BLDG. #5 THREE FIRE INSPECTIONS
Applicant: Owner:
REAL ESTATE COLLATERAL MANAGEMENT
CO
C/O LIZ LAYMAN/ MORROW DEV
1903 WRIGHT PL #180
CARLSBAD CA
Fees ($) Add'l Fees ($) Total ($) Balance ($)
165 0 165 0
1/1
A3o3o2-22--
RIAL [DATA SUBN1177AL .
Lo Costa Greens
Building #5 1937 Dove Lone
Carlsbad,
LIFEGUARD FIRE PROTECTION, INC.
205 TEMPLE HEIGHTS DRIVE, STE. F
OCEANSIDE, CA 9205
700-80-9997 • 760-80S-4813 FAX
as
DOUBLE CHECK DETECTOR ASSEMBLY
BACKFLOW PREVEN11ON
Physical Properties U.S Patent No. 4.989.W5 • U.S Patent No.6.107,688
U.S. Patent No.5,385,166 • U.S. Patent No. 5226441
Size of Mainline U.S Patent No.5,392.803 • U.S Patent No, 6,5W,176 21I2M, 3 40, 80, 8, & 10"
Max. Working Pressure 175 PSI (1200 KPa)
Hydrostatic Test Press. 350 PSI (2400 KPa) dh
Temperature Range 32° F to 140° F
a,
(00 C to 600 C)
End Connections Flanged ANSI B16.1
Class 125
Materials
Main Valve Body Ductile Iron Grade 65-45-12
Coating Fusion epoxy coated
internal and external
AWWA C550-90
MODEL 876V DOUBLE CHECK DETECTOR
(Shown In vertical position)
Shut Off Valves OS & V resilient wedge
gate valves AWWA C509
Trim Bronze
Elastomer Discs EPDM
1( Spring Stainless steel
MODEL 8761876V DOUBLE CHECK DETECTOR
Installation Views (Shown In standard orIentation)
I I
18m1n 18mk rl
Suppcit uhedbycu,tomei) ialv.wdght only.
In
FLOW
Standard orientation (Model 8766/876V)
* Note-Model 876 does not include grooved end coupling.
Recommended minimum clearances from permanent structures for
ease of testing and maintenance.
Vertical orientation (Model 876V)
VASIT E I
LS
5TM D2000
3TM D1999
sin
)y C83800
y C83600
509
y C83600
)y C83600
C83600
SIM 02000
TM 02001
260
260
yC83601
Dy C83602
C26000
C26000
Steel
606
RIP
Model 876V Model 876V
Standard Orientation Vetticl Odatatiai
Note: The Model 876V is shipped in the
standard (N-Shape) orientation as shown
below.
arooved end
08 &Y
Side View
Dimensions Approximate
El Net.
Os&Y Os&y
Size A B C OPEN F G H J K M (Lbs.)
211211 12'Ia 253k 24'14 16Ia 1611e 61I4 111h 3112 131a 2714 230
65 317.50 654.05 615.95 415.93 422.28 158.75 292.10 88.90 348.08 692.15 104.33
3 1211a 25I4 2414 22½ 16!a 6114 11'12 3314 1411e 28½ 300
80 317.50 654.05 628.65 565.15 422.28 158.75 292.10 95.25 358.18 717.55 136.08
4 14 27 "Is 2614 2314 17/4 7 13 4112 15112 31 330
100 355.60 708.03 679.45 590.55 450.85 177.80 330.20 114.30 393.70 787.40 149.69
611 16 32114 32114 30110 2117 8 13 5112 1861e 3714 520
150 406.40 819.15 819.15 765.18 547.9 203.20 330.20 139.10 473.08 946.15 235.87
8" 18112 371I2 38318 37314 24½ 9½ 14'/2 6I4 204 41/2 860
200 469.90 952.50 923.93 958.85 631.80 234.95 368.30 171.45 527.05 1054.10 390.09
10" 21 42'I2 4014 48 27'I2 10 15 8 24 48 1460
250 533.40 1079.50 1035.05 1219.20 698.50 254.00 381.00 203.20 609.60 1219.20 662.24
Weights do not Include risers or optional valve setter.
Note; Dimensions shown are nominal. Allowances must be made for normal manufocturiog tolerances.
Refer to Specification Sheet SS VS for details on valve setter.
E, Iq
I
Application
Non-Health Hazard Fire Spnhkler Systems
Flow Orientation
Standard orientation is inlet flow Vertical up, outlet flow
vertical down. Vertical orientation is inlet and outlet flow
vertical up.
Options
0 Valve Setter with MJ x FL, MJ x MJ
or FLxFLends
Agency Compliance
Approved by the Foundation for Cross
Connection Control and Hydraulic Research
at the University of Southern California.
ASSE (Std. 1048)
ANSI/AWWA (C510-89)
CAN/CSA (B64.5)
FM
UL*
cUL
* Less gate not FM approved.
Less gate not UL listed unless Installed with UI. listed
gated valves.
Model 876/876V Flow Curves
f1- - - --
W - --- - / tA - -- - - ---- - ----- -
I I II S II I II
8"
-
16
14
12
10
0
A
0 500 1000 1500 2000 2500 3000
GPM
of 10" 18
16
14 12
810
-
86
2
Bi
16
14
12
10
38
2
B
0 100 200 30D 400 500 600 700
GPM
A-Vertical orientation (modal 878V)
B-Standard orientation (model 876)
FESCO Backflow Prevention
P.O. Box 8070• Fresno, CA 93747-8070
559 252-0791 Fax 559453-9030- Www.cmb-Ind.com
85876V OWl COMM MM ONSkidir(ee. MM
0 1000 2000 3000 4000 5000
GPM
The 6" and 10" flow curves in the standard orientation
include the FESCO valve setter model 611.
CM Imbtdas, Inc.
*dlnsn1sunm,
ISO 9001 Certified
Schedule-1O/Schedule-40
Fully Listed and FM Approved Sprinkler Pipe
When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these
products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand.
Our Sch-10 (1',"- 8") pipe and Sch-40 (1"- 2") pipe have passed the same thorough lab testing as our other listed pipe
products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality.
Schedule- 10/Schedule-40 product can be
"hot-dip" galvanized to meet FM
requirements for dry systems in
accordance with the zinc coating
specifications of ASTM A-123.
Our advanced formula mill coating of-
fers a clean, durable surface. It is also
paint-ready for custom color applications
without special preparation.
The internal surface of all black Allied
Tube & Conduit Fire Sprinkler pipe
products up to 4.5000" in diameter is
coated with our new Antibacterial For-
mula, "ABF". in scientific laboratory
test, ABS proved to have superior resis-
tance to microbial colonization of pipe
walls, thereby delaying or possibly pre-
venting the onset of Microbiologically
Influenced corrosion (MIC) when the
First Sprinkler System is first installed.
Meets "Buy American" requirement
and is available through distributors in
the USA. Canada and Mexico.
Speci fications
NPS Nominal I.D. WI. WI. (H20 Filled) PrJ WVLift (21) WIILIft (24) WI/LIft (25)
In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg
1' 1.049 1.680 2.05 70 2,470 2,822 2,940
25 26.6 25 3.05 70 1,120 1,280 1,334
1W 1.380 2.270 2.93 51 2,431 2,778 2,894
32 35.1 4.36 4.36 51 1,103 1,260 1,313
1W 1.610 2.720 3.61 44 2,513 2,872 2,992
40 40.9 4.0 5.37 44 1,140 1,303 1,357
2 2.067 3.650 5.13 30 2,300 2,628 2,738
50 52.5 5.4 7.63 30 1,043 1,192 1,242
21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750
65 62.7 8.6 11.73 19 1,048 1,197 1,247
r.m.
NPS Nominal I.D. WI. WI. (1120 Filled) Pci! WI/Lift (21') WI/LIlt (241) WtlIJft (25')
In; mm In; mm Lbs/Fl; Kgfm Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg
1 1.097 1.400 1.81 91 2,675 3,053 3,185
25 27.9 2.1 2.70 91 1,213 1,385 1,445
11/4' 1.442 1.810 2.52 61 2,319 2,664 2,760
32 36.6 2.7 3.75 61 1,052 1,208 1,252
1W 1.682 2.080 3.04 61 2,664 3,045 3,172
40 42.7 3.1 4.52 61 1,208 1,381 1,439
2.157 2.640 4.22 37 2,051 2,344 2,442
50 54.8 3.9 6.28 37 930 1,063 1,108
2W 2.635 3.530 5.89 30 2,224 2,542 2,648
65 66.9 5.3 8.77 30 1,009 1,153 1,201
3.260 4.330 7.94 19 1,728 1,975 2,057
80 82.8 6.4 11.82 19 784 896 933
4.260 5.610 11.78 19 2,238 2,558 2,665
90 108.2 8.3 17.53 19 1,015 1,160 1,209
5.295 7.77 17.33 10 1,632 1,865 1,943
125 134.5 11.56 25.80 10 740 846 881
6.357 9.290 23.03 10 1,951 2,230 2,322
150 161.5 13.8 34.27 10 885 1,012 1,053
8 8.249 16.490 40.15 7 2,424 2,770 2,885
200 209.5 24.5 59.75 7 1,100 1,256 1,309
Schedule-10/Schedule-40 pipe are in
compliance with the following:
ASTM A-135, and NFPA 13. Both pipe
products have a working pressure rating
of 300 psi maximum and also meet the
stringent requirement for the following
tests:
Welded Outlets
Hydrostatic Pressure
Side Wall Rupture
Vibration Test
tqCo/Flow Control allied
TUBE & CONDUIT
@ <~> 0
Listed Approved Listed
16100 S. Lathrop • Harvey, IL 60426 Customer Service:
11350 Norcom Rd.. Philadelphia, PA 19154 (800) 882-5543
2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806
S5-3
Super Flo(D/DynanFlowe
Aigh Strength Steel Pipe-,
The original high-strength !ightwall sprinkler pipe with hydraulics superior to Schedu!e-10.
Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Litt Wt/Lfft Wt/Lift
NPS 1. D. H20 Filled Lift 21' 24' 25'
X 1" 1.191 0.830 1.31 91 1586 '1812 1888
*25 30.3 1.2 1.95 91 719 822 856
'11/4" 1.536 1.059 1.87 61 1356 1550 1615
*32 39.0 1.6 2,78 61 615 703 733
x11/2" 1.728 1.667 2.71 61 2135 2440 2542
*40 43.9 2.5 4.03 61 968 1107 1153
2.203 2.104 3.79 - 37 1634 1868 1946
*50 56.0 3.1 5.64 37 741 847 883
2 1/2" 2.703 2.564 5.10 30 1615 1846 1923
*65 68.7 3.8 7.59 30 733 837 872
3.314 3.387 7.18 - 19 1351 1544 1608
*80 84.2 5.0 10.69 19 613 700 729
x 4" 4.310 4.473 10.86 19 1784 2039 2124
*90 109.5 6.7 16.16 19 809 925 963
X 6" 6.403 7.714 21.70 - 10 1620 1851 1928
*150 162.6 11.5 32.29 10 735 840 875
Specifications & Approvals
Super Flo/Dyna-Flow pipe is • Lightweight and easy to install,
manufactured to meet ASTM A- resulting in more efficient use of
795 97ype E, Grade A and is in your freight and labor dollars.
compliance with NFPA-13 and
NFPA-14. All sizes of Dyna. • Provides stability needed to
Plow/Super Flo are UL Listed, comply with standard hanger
FM Approved and ULC Listed. spacing (15 ft O.C.) per NFPA,
Super Flo/Dyna-Flow pipe is the "original"
high-strength lightwall sprinkler pipe.
Super Flo/Dyna-Flow has outstanding
hydraulic capabilities and is recognized
as the most popular alternative to
Schedule-10 pipe. Lightweight, easy to
cut and easy to handle for installation.
Super f?lo/DynaF1Ow is a valuable
addition to any fire protection system.
superior Hy r'1 t'-
With an inside diameter of up to 11%
larger than Schedule-40 and up to 7%
larger than Schedule-10, SuperFlo/
Dyna-Plow pipe hydraulics are exceptional.
get I.D.s enable SuperFlo/Dyna-Flow,
aid related components, to be down-
sized within the system, thus increasing
the potential for job cost savings. For
complete Hazen-Williams charts, refer to
"Super Flo/Dyna-Flow Hydraulic Data
Tables."
Super Plo/Dyna-Flow products are coated
with an environmentally approved and
specially formulated modified-acrylic or
water-based coating. This durable coating
is pa1nr4b1e. The black coating acts as
an excellent primer and is resistant to
weathering and U.V. degradation from
outdoor storage.
Metallurgical properties provide excellent
fabrication characteristics for end prep
finishes, welding and roll grooving. No
.-'cial process or equipment are needed
fabrication and installation.
-n allied
TUBE & CONDUIT
IlICAl.lr
(@ 0 L_L~c
Listed Approved Listed
Super Flo/Dyna-Fi ow is ULIULC
Listed for use with roll grooved,
plain-end couplings, and welded
joints for wet, dry, preaction and
deluge systems. It is FM Approved
for roll grooved, plain-end, and
welded joints for wet systems.
Refer to appropriate documentation
for up-to-date listing and approval
information. Super Flo/Dyna-Flow
is now available "hot-dip"galvanjzed
and has been specifically approved
by FM for dry systems uses.
Available in Standard lengths
for your convenience, or can be
ordered in custom lengths
upon approval. -
Fast cutting and-welding, as well
as easy roll grooving and end
preparation.
Available in Factory roll grooved
form for quicker shop turnaround.
Clean, durable mill coating
provides longer "shelf life" and
acts as an excellent primer for
custom paint applications.
16100 S. Lathrop 11350 Norcom Rd. 2525 N. 27th Ave. Customer Service:
Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 1-800-797-6210
Fax 70,9-339-1806
Submittal Data Sheet
Super 407Dyna-Thread
Full Line Sch-40 Replacement
Super -lWDyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler
pipe industry. U combines the safety and longevity of traditional Sch-40 pipe with quality and
superior hydraulic acl van taties.
Comparison to Schedule 40 Super 40IDyna-Threads inside diameter is UP to 3.6%
lartei than Sch--10 giving i superior hydraulics. Also, when used in combination with Dyna-Flow
pipe down sizing often occurs. Super 40/Dyna-Thread is fully listed and approved UL. ULC, and
FM for lire sprinkler applications. The life expectancy of Super 40/Dyna-Thread and Sch-40 are
equal based on the calculated wall thicknesses per UL (see CRR). The consistent quality of steel
ud to make Super 40/Dyna-Thread facilitates smooth threading and lower maintenance costs.
The exterior ui Super 40/Dna-Thread is protected by a clean durable mill coating for extended
iel1 life and easy paint application. With its increased strength and lighLer weight. Super40/
D na-Thread reduces installation fat iue and is ideal for reiro- fit applications. Corrosion
R'otance Ratio lCRRl is a UL. (Underwriters Laboratory) term for the estimated life expectancy
ot it pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread,
a'sttmed to be the weakest point of the pipe length. Super 40/Dyna-Thread and Sch-4() have the
une calculated wall thicknesses at this point and are both assigned the same CRR of 1.00.
Comparison to L.W.T.Pipe More wall thickness at the thread (C1ZR=1.00) gives
Super 40/Dynu-Thread better life expectancy than highiwall threadable pipe joints. Unlike
lighiwall threadable pipe. Super 40/Dyna-Thread has no thread gtiLige warning. Super 40/
Dyna-Thread is approved for standard hanger spacing (15 ft. 0.6, can be used as earthquake
sway lracing. and is safe to use as drops. Super 40/Dynu-Thread is safer to weld on than many
zinc-coated lighiwall threadable pipe products. Super 40/Dyna-Thread is more widely accepted
than ligluwall Lhreadable where Sch-40 is specified.
Spcifications & Approvals
Super4O/Dyna-Thread pipe is manulitctired to
meet: ASTMA 135. Grade A and is in compliance
tb NFPA- 13. All sizes of Super 40/Dyna-Thread
are rated at 300 psi working pressure. Super 40/
[)ma-Thread is UL and ULC Listed for wet, dry
and pre-action sprinkler systems and FM Approved
br use in wei systems. Super 40/Dyna-Thread can
be "hot-dip' galvanized io meet FM requirement
fur dry vsiems. Super 40/Dyna-Thread is approved
or all threaded couplings and Welded outleLs and is
suitable for all roll-grooved, and plain-end fittings.
(See listing information).
(9-L 0 0
Llwd Approv,,i LlIed
Slump Hero
Product Nominal Wt/Ft Wt/Ft Pcs/ Wt/Lilt Wt/Lift Wt/Lift
NPS 1.0. H20 Filled Lift 21' 24' 25'
1' 1.080 1.330 1.75 70 1955 2234 2327
*25 27.4 2.0 2.60 70 887 . 1013 1056
x 1 1/4" 1.408 1.870 2.54 51 2002 2288 2384
*32 35.8 2.8 3.78 51 908 1038 1081
x 1 1/2' 1.639 2.290 3.22 44 2115 2418 2519
*40 41.6 3.4 4.79 44 959 1097 1143
x 2" 2.104 3.050 4.57 30 1921 2196 2287
50 53.4 4.5 6.80 30 871 996 1037
Ainericn Tube and Pipe was acquired by Allied Thbe and Conduit on February 1, i99. The engineered lightwall and standard wall family of products although they
httre diflrent names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flu are the
same product as ate Dynn Thread and Super 40. XL is manufactured with Exterior galvanized coaling. BLT is manufactured with Black lacquer e0a1ng,
Project: Sprinkler Contractor: Date:
Engineer: Specification Reference: System Type:
Locations: Comments:
Flow Data
Friction Resistance
The chart expresses the frictional
resistance of various Victaulic
firings as equivalent feet of
straight pipe. Fittings not listed
can be estimated from the data
given, for example, a 221/2' elbow
is approximately one-half the
resistance of a 450 elbow. Values of
mid-sizes can be interpolated.
I
Grooved IPS Fittings
Victaulic fittings are designed specifically for use
in grooved piping systems.
Victaulic offers a broad line of
fittings in sizes through 24"
(600 mm) in a variety of straight
and reducing styles. Most standard
fittings are cast of durable ductile
iron to precise tolerances. Victaulic
standard fittings pressure ratings
conform to the ratings of Vicraulic
Style 77 couplings.
All fittings are 'supplied with
grooves or shoulders to permit fast
installation without field
preparation. The grooved design
permits flexibility for easy
alignment. These fittings are not
intended for use with Victaulic
couplings for plain end pipe (refer
to page 55 for fittings available for
plain end applications).
Fittings are provided in various
materials including malleable iron,
ductile iron, steel or segmentally
welded steel depending on styles
and size. Fittings pre painted
orange enamel with galvanized
optionally available, contact
Victaulic for details.
Vicmulic fittings are designed
specifically for use in grooved
piping systems. Fittings are
provided grooved or with
shoulders conforming to standard
steel pipe outside diameters. When
connecting wafer or lug-type
butterfly valves directly to
Victaulic fittings with 741 or 743
Vic-FlangeO adapters, check disc
clearance dimensions with I.D.
dimension of fitting.
Request 07.01.
Alternate Materials
Stainless Steel - Grooved end
fittings are available in Schedule 10
Type 316 stainless steel (Schedule
5, 40 and Type 304 optionally
available) in various sizes. Fitting
center-to-end dimensions will vary
depending upon r1q.e and
schedule.
Request 17.04 for details.
Aluminum - Grooved end fittings
are available in aluminum alloy 356
T6, in sizes from 1 - 8' (25 - 200
mm). Request 21.03 or contact
Victaulic for details.
Alternate Styles
EndSeal® "ES" Fittings -
EndSeal fittings are available in 2 -
12(50- 300 mm) for use with "ES"
grooved pipe and FJP-70ES
EndSeal or Fire-Em couplings.
"ES" fittings are painted green for
easy identification. EndSeal (an1
standard) fittings may be easily
internally coated (by others) for
severe service requirements.
Always specify "ES EndSeal
fittings' when ordering.
Request 07.04 for information on
EndSeal fittings.
Fittings Machined for Rubber
or Urethane Lining (MEL) --For
severe abrasive services, Victaulic
fittings may be rubber or urethane
lined (by others). Lining may be
inside diameter/end (abrasion:
resistance) or wrap-around
(corrosion and/or abrasion)
machined.
Request 26.03 or contact Victauuic
for specific details.
Pipe Pipe
Inches/mm Equivalent Feet/meters at Straight Pipe Inches/mm Equivalent Feel/meters 01 Straight Pipe
-
- 901 Elbows 45° Elbows Tees 90° Elbows . 45° Elbows lees
No.100 No. 110 No. 100 No. 110
No.10 1½0 No. 11 1½1) No.10 113tD No. 11 1½0
Nom. Actual Std. Long Sid. Long Nom. Actual Sid. Long Sid. Long
Size Size Radius Radius Radius Radius Branch Run Size Size Radius Radius Radius Radius Branch Run
1 1.315 1.7 - 0.8 - 4.2 1.7 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0
25 33.7 0.5 0.2 . 13 0.5 150 1683 30 2.3 1.5 0.9 76 30
2 2.375 3.5 2.5 1.6 1.1 8.5 3.5 6.500 9.6 -. 5.0 - 25.0 10.0
50 60.3 1.1 08 05 0.3 26 ii 6½1: 1651 2.9 - 15 7.630
3.000 4.3 -. 2.1 -- 10.8 4.3 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 31: 76.1 1.3 - 07 .. 33 1.3 200 2191 4.0 3.0 2.0 1.2 101 40
3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 10 10.750 17.0 12.0 8.3 5.0 41.0 170
80 86.9 15 12 08. 0.5 40 1.5 250 273.0 52 3.7 2.5 1.5 12.5 5.2
4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0
100 1143 21 iS 10 06 49 2.1 300 3239 6.1 4.4 30 1.8 15.2 61
4,250 6.4 - 3.2 - 15.3 6.4 14 14.000 # 23.0 II 18.0 60.0 17.0 4/41: 106.0 1.8 09 . 47 20 350 3556 ii 7.0 It 5.5 1113 5.2
5 5.563 8.5 - 4.2 -. 21.0 8.5 16 16.000 # 26.0 II 20.0 70.0 20.0
125 141.3 2.6 1.3 -. 6.4 26 400 79 II 61 213 61
5.250 8.1 - 4.1 - 20.0 8.1 18 18.29.0 Ii 23.0 80.0 23.0 5¼41330 25 - 1.6 -. 6.22.5450457 8.6 13 70 24.4 70
5.500 8.5 - 4.2 - 21.0 8.5 2E.5%1: 20
'106t4l
20.33.0 41 26.0 90.0 $39.72.6 - 1.3 .-. 6.4 2.6 500 50 10.1 Ii 7.9 27.4 7.6
6.250 9.6 - 5.0 -. 25.0 10.0 24 34.150.0 24.40.0 # 30.0 30.5 2.0 -- 15 . 76 30 600 61 12.2 13 iii 93 10.4
13 Contact Victaulic for details.
1: O.D. Dimension.
14
Style 77
Standard
Flexible Coupling
LAOQC~ ~S5
3/4 - 12" Sizes 14 - 22° Sizes
Style 77 couplings are designed
with cross-ribbed construction to
provide a strong component for
pressure piping systems. Sizes
V4 -12(20-300 mm) are two-piece
housings. Sizes 14 - 22°
(350 - 550 mm) are cast in tour
identical segments, with larger
sizes cast in six segments.
Request 06.04.
Y .*1zr
24' Size
Style 07 The unique angle-pad design of
ZeroFlex® Style 07 adjusts to
Zero-Flex Rigid Coupling standard pipe and roll or cut
(
groove tolerances, positively Q Clamping the pipe to resist flexural
and torsional loads. Wider key
L
section tills more of the groove
area.
Request 06.02.
- i 1 z
2- 12" Sizes 14- 16° Sizes 18- 24" Sizes
0 rG
PS
ROOVED' COUPLING'S:
Nom.
Size
Max.
Work Press. Dimensions - Inches/mm WgIEach
X Y Z Inches/mm PSr/kPa Lbs.atg
1 750 2.45 4.13 1.88 1.6
02 105 .413 0
11/4 750 2.60 4.00. 1.88 1.6
I .1i 01) 11)2 433 13;
1½ 750 2.94 4.81 1.88 1.6
III :11,.m :i 122 413
2 750 3.19 5.44 1.88 2.3
10 .'1713 3) iii 10
21h 750 3.88 6.13 1.88 2.8
933 151) 40 13
750 4.25 5.75 1.86 3.6 3:1: : 'tifl 1433 . 1.0
3 750 4.56 6.81 1.88 3.1
I IS 173 1) 1.1
4 750 5.81 8.25 2.06 4.8
iou -I" itI 211) 52 22
750 5.56 7.44 2.06 5.2 4!/4 1: 17, 1.11 HO 1):' .4
5 750 7.06 9.75 2.06 7.1 -) 2.18 .12
700 6.36 9.18 2.06 7.4 5¼t 'IlL'! 74 233 52 34
700 6.94 9.42 2.06 7.6
6 700 8.00 10.75 2.06 8.7
1:mt) 4825 203 :1.4 52 3
700 7.85 10.18 2.06 9.2 6¼ .1: .",
700 0.00 10.75 2.06 7.2 6%1: o3 23 52 3
B § 600 10.25 13.50 2.50 14.9
.1 IkI 7)30 I. 64
10§ 500 12.88 16.75 2.56 25.0
I.'t3 65
12 § 400 14.88 18.50 2.56 28.2 :100 :1) i:;, 66 I;? o
14 300 16.19 19.75 2.94 32.8
350 .'1k2m 411 'it' 75 41)
16 300 18.38 21.75 2.94 41.2
.10) '(53.5
18 300 20.69 23.88 3.06 54.2
150 20,13, 526 006 733 24 1)
20 300 23.00 27.38 3.06 67.2
nikl :•s;s ()
24 250 27.13 31.50 3.13 76.2
NO 17:':, .1)5) 31)0 79 40
U.U. ummension. here, to notes on page i. Avahlaoie to j.i.. almenslon
Noni.
Size
Max
Work Press. Dimensions - Inches/inni Aprx.
W9I. Each
X V Z Inches/mm PSI'/kPa Lbs./Ig
~ 1.000 2.13 3.63 1.75 - 1.1 0!-
1 1,000 2.38 3.88 1.75 1.3
LIOUO I,0 03 .1.1 (11)
11/1 1,000 2.63 4.63 1.75 - 2.0
.42 13IO1) 07 111; .14 1)1)
1½ 1.000 3.00 5.00 1.75 - 2.1
'ii 0'.kl1) '0 1:1..1.1 Ii)
2 1,000 3.63 5.63 1.75 - 2.6
6900 1)2 143 If
21A 1,000 4.25 6.25 1.75 - 3.1
05 1)900 IN; list 14 14
1,000 4.31 6.31 1.75 3.6 3 4 000 1 1 lu.) 14 16
3 1,000 5.00 7.00 1.75 3.5
Lit) 03100 12 1:6 .14 1 Ii
3½ 1.000 5.63 8.00 1.75 - 5.6
'30 1)900 1.13 20.3 .1.1 'S
4 1.000 6.38 8.50 2.00 - 6.6
.11100 lu$ .!id Si . :111
4/i 4 1.000 5.88 8.06 2.06 - 7.0
111)1)0 149 .111:1 :m.'
5 1.000 7.63 10.25 2.00 10.6
61)0t) 19.1 21)0
5h 4 1,000 7.34 9.20 2.06 - 10.0
isa j4 .1. 4 5
1,000 7.60 9.44 2.06 - 11.0 5½ 4 uoii 11)3 140 :0' 1.1) -
6 1.000 9.00 11.50 2.00 11.8
1.59 I33IH) 271) 5)' 31 :,4
1.000 8.50 10.38 2.06 - 13.2 61/4 t 01)0(3 211) 'i.I :':' dl)
1,000 9.19 11.50 2.06 - 13.2 61 4 booi) 2:3:1 MO :'O mitt
800 11.38 14.50 2.38 - 20.1
IL :61)0 2330 .41)1) 1)0 tIl
10§ 800 13.50 16.75 2.50 28.3 :1500 . 343 .i5 1W 211
12 § 800 15.50 19.00 2.50 34.2
.391) &11) .19.1 33.4 04 1.5:
14 300 16.63 20.00 2.88 - 35.6
:120 oss 47:1 s.0) ill I
15 300 17.88 21.25 2.88 - 48.8
16 300 19.00 22.38 2.86 - 51.1
18 300 21.25 24.38 3.13 64.4
'0335 241' al'% 70
20 300 23.50 27.50 3.13 - 91.2 1,01) 7ihi 21) 1131)) t) 41
22 300 25.83 30.00 3.13 - 92.0 510) 20c33 0;' 70 41:'
24 250 27.63 31.38 3.13 - 94.0
1725 '02 1' IT -
O.D. Dimension. . Refer 10 notes on page 7. § Available to J.i.S. aimeflsiOfl.
Size Range - 1/4 thru 1-1/2 inch rod in 10'-0"
lengths.
Material - Carbon Steel
Maximum Temperature - 750°F
Finish - Plain, Electro-Galvanized, and Stainless
Steel.
Order By - Figure number, rod diameter, and
finish.
MAX. REC. LOAD LBS, APPROX.
ROD FOR SERVICE TEMPS WEIGHT
SIZE 650°F 750°F PER 100 FT.
1/4 240 215 12
..t
1/2 1130 1010 .53
3/4 2710 2420 123
JLL?PL9
1 4960 4420 222
1-1/2 11630 10370 510
FIG. 99
ALL THREAD ROD CUT TO LENGTH
Size Range - 3/8 thru 7/8 inch rod in 1 inch
increments.
Material - Carbon Steel
Maximum Temperature - 750°F
Finish - Plain, Electro-Galvanized, and Stainless
Steel.
Order By - Figure number, rod diameter, rod
length, and finish.
MAX. REC. LOAD LBS.
ROD FOR SERVICE TEMPS.
SIZE 650°F 750°F
3/8 610 540
1/2 1130 1010
5/8 1810 1610
3/4 2710 2420
7/8 3770 3360
FIG. 100
ALL THREAD ROD FULL LENGTHS
____ TOL o ._____ INOOIPOIiATP
CORONA. CA • (909) 737.5599 15
FIG. 2 ADJUSTABLE RING HANGER
FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE
Size Range - 1/2 thru 6 inch pipe.
Material - Carbon Steel, Mu. Galvanized to G.90
specification.
Function - For general piping purposes. Knurled
swivel nut design permits hanger adjustment after
installation. Spring tension on swivel nut holds it
securely in hanger before installation. Swivel nut
easily removed.
Approvals - Underwriters' Laboratories listed and
Factory Mutual Engineering approved. Conforms
to Federal Specification WW-H-171E, type 10, and
Manufacturers Standardization Society SP-69,
type 10.
Maximum Temperature - 650°F
Finish - Mil. Galvanized and Stainless Steel.
Order By - Figure number and pipe size.
PIPE ROD STOCK
MAX.
REC.
APPROX. WEIGHT PER 100
FIG. 2
SIZE SIZE A 8 C SIZE LOAD LBS. FIG.2 NFPA
1/2 3/8 3.1/8 2.5/8 1.3/8 lôgaxi 400 17 17
-' $18 312 U/8. 1 x 40Q
1 3/8 3-3/8 2-5/8 1-1/8 169a x 400 18 18
$J &9/4 L7/ UY83 J6&i. 400
1-1/2 3/8 3-7/8 2-7/8 1 16gax1
-
400 21 21
2. Li6aaj1. 400 . --
2-1/2 1/2* 5-3/4 4-1/4 1-5/8 149a 1-3/16 600 41 40
LI 1Lt J4$?1 3/16 600 11 -a Lai
3-1/2 1/2* 7.3/8 5-1/4 2-1/8 14gax 1-3/16 600 52 50
1LLt?JLLJ :L8 U11JI4 1000 ;,
k.
L
5 5/8** 9 6-1/8 2-1/4 129ax1-1/4 1250 97 95
8/4 '.9 3/8 1/ ' 7/8i , 1gax 14/4 1250 139
3/8 nut Is used when NFPA rod sizing is requested.
801/2" nut is used when NFPA rod sizing is requested,
TD____
- INCORPORATED
120 CORONA. CA • (909) 737-5599
FIG. 1000
"FAST CLAMP" SWAY BRACE ATTACHMENT
Size Range - Pipe size to be braced: 1" through 8"
Sch. 10 and 40. Pipe size used for bracing: 1" and
1-1/4" Sch. 40 IPS.
Material - Carbon Steel
Function - For bracing pipe against sway and
seismic disturbance. The pipe attachment com-
ponent of a sway brace system: Fig. 1000 is used
in conjunction with a Tolco 900 Series Fitting and
joined together with bracing pipe per NFPA #13*,
forming a complete sway brace assembly.
Features - Can be used to brace Schedules 10 and
40 IPS.
Field adjustable, making critical pre-engineering of
bracing pipe unnecessary,
Unique design requires no threading of bracing
pipe.
Can be used as 4-way riser brace.
Can be used as longitudinal brace.
All steel construction eliminates structural
deficiencies associated with casting type sway
brace fittings.
Comes individually packaged with illustrated
installation instructions - sizes are clearly marked.
Steel leaf spring insert provided to assure installer
and inspector that necessary minimum torque
(5 lb/ft) has been achieved.
Application Note - Fast Clamp need not be field
assembled. Position Fast Clamp and tighten two
hex nuts until leaf spring flattens.
*Length of bracing pipe per National Fire
Protection Association, Pamphlet #13, paragraph
A-3-10.3.5: 1" Schedule 40 bracing pipe maximum
7'-2". 1-1/4" Schedule 40 bracing pipe maximum
9'-2".
Approvals - Underwriters' Laboratories listed.
Note - Must be used with Tolco U.L. Listed 900
Series attachment.
Finish - Plain, Electro-Galvanized, HDG, and
Stainless Steel.
Order By - Order first by pipe size to be braced
followed by pipe size used for bracing, figure
number, and finish.
-
IL(
118
0 T .00 &L
INCORPORATED
CORONA. CA • (909) 737.5599
FIG. 910
SWIVEL SWAY BRACE FITTING
Size Range - 1 & 1.1/4 inch bracing pipe.
Material - Carbon Steel
Function - For bracing pipe against sway and
seismic disturbances. The building attachment
component of a sway brace system; The Fig. 910 is
used in conjunction with the Fig. 1000 "Fast
Clamp" (or with a Fig. 4A Pipe Clamp), and joined
together with a brace pipe per NFPA #13*.
Features - Universal swivel design allows Fig. 910
to be attached at any surface angle. All steel
construction eliminates deficiencies associated
with casting type attachments.
Application Note - *Length of bracing pipe per
National Fire Protection Association Pamphlet
#13, paragraph A-3-10.3.5: 1" Schedule 40 bracing
pipe maximum 7-2". 1.1/4" Schedule 40 bracing
pipe maximum 9'..2".
Approvals - Underwriters' Laboratories listed.
Note -The Fig, 910 Swivel Attachment and the Fig.
1000 "Fast Clamp" (or Fig. 4A Pipe Clamp), make
up a sway brace system of U. L. Listed attachments
and bracing materials which satisfies the
requirements of Underwriters' Laboratories and
the National Fire Protection Association (NFPA).
Finish - Plain, EIet.rQ-&vanized, and Stainless
Steel.
Order By - Figure number, pipe size, and finish.
Note - Specific weight load conditions may require
more than one fastener to the building structure.
Swu hrarp attrhmnts mau be ordered with
/—D
I.'
ni
limp
0 AP I1I MOLE SIZE A B C SIZE E F PER 100
2 1-1/2 3 9/16 2.5/16 2 88
4.
BRECCO Brecco Corporation
>GAUGES
GAUGES
FOR USE WITH WET OR DRY
SYSTEMS. GAUGES HAVE A
BRONZE BURBON TUBE
MOVEMENT IN A STAINLESS
STEEL PLATED CASE
(UNLESS OTHERWISE
NOTED). 3-1/2" DIAMETER.
U.L. AND F.M. APPROVED
(UNLESS OTHERWISE
NOTED).
Part No. - Description BoxCasi
GAAWSS350 AIR / WATER 0- 300 PSI 60 - WI STAINLESS STEEL CASE
GM88250 AIR W/ RETARD 250 PSI
3-1/2" DIA, WI STAINLESS STEEL 80 CASE
GAWP200 2" RESIDENTIAL GAUGE 300 PSI
100 (NOT U. L. OR F. M. APPROVED)
GAAWP350 AIR (WATER WI PlASTIC CASE 60
11-866.543-4-1 ! 94 Fax: 1•877474-9248 AR = AS REQUIRED breccocam@eadhiink.net
082000
To @a U
INCORPORATED
CORONA. CA • (9091737 -5599 41
FIG. 51 AND FIG, 52
SIDE BEAM BRACKETS (CONT)
H-3(4)
LH
LH-2—
A LCJ
FIG. 51 FIG. 52
FIG. 51 for NFPA Rod and Fastener Sizing
APPROX.
PIPE ROD HOLE SIZE STOCK WEIGHT
SIZE SIZE A B C H-i H-2 SIZE PER 100
1/2 -2 3/8 2 3/4 2 7/16 7/16 3/16x2 35
9/J6 7/16 r i
5-6 1/2 2-1/2 3/4 2-1/2 9/16 9/16 3/8x2-1/2x2.1/2 71
9116 /8.x2 xg 1/2 7Q I
FIG. 52 - 6 Hole Bracket
APPROX.
ROD HOLE SIZE STOCK WEIGHT
SIZE A B C H-i H-2 H-3 SIZE PER 100
3/8x1/2 2 1-1/16 2 9/16 7/16 9/32 3/16x2 35
FIG. 56
TAPPED SIDE BEAM CONNECTOR
Size Range - 1/2 thru 4 inch pipe (3/8 inch rod).
Material - Carbon Steel
Function - Practical and economical bracket used
to support hangers from steel or wood beams. Can
be used with concrete shot-type inserts. Tapped
hole allows easy adjustment of hanger rod.
Approvals - Underwriters' Laboratories listed and
Factory Mutual Engineering approved for 1/2 - 4"
pipe.
Finish - Plain, Electro-Galvanized, HDG, and
Stainless Steel.
Order By - Figure number and finish.
Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8
inch fastener; 2-1/2 thru 4 inch pipe use 1/2 inch
fastener.
G
A H
F
L J ~ C,
ROD APPROX, PIPE SIZE HOLE SIZE STOCK WEIGHT SIZE A B C D E F G H J SIZE PER 100
1/2 - 4 2-5/8 3/8 1 3/8 1-1/16 1.1/8 7/16 9/16 1-1/4 1/4x1 20
tqC01Ffre & Building
Products
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
Series LFII Residential
Pendent Sprinklers
49 K-factor
Customer Service/Sales:
Tel: (414) 570-5000/(800) 558-5236
Fax: (414) 570-5010/(800) 877-1295
General
Description
The Series LFII (TY2234) Residential
Pendent Sprinklers are decorative,
fast response, frangible bulb sprinklers
designed for use in residential occu-
pancies such as homes, apartments,
dormitories, and hotels. When aesthet-
ics and optimized flow characteristics
are the major consideration, the Series
LFII (TY2234) should be the first
choice.
The Series LFII are to be used in wet
pipe residential sprinkler systems for
one- and two-family dwellings and mo-
bile homes per NFPA 131); wet pipe
residential sprinkler systems for resi-
dential occupancies up to and includ-
ing four stories in height per NFPA
13R; or, wet pipe sprinkler systems for
the residential portions of any occu-
pancy per NFPA 13.
The Series LFII (TY2234) has a 4.9
(70,6) K-factor that provides the re-
quired residential flow rates at reduced
pressures, enabling smaller pipe sizes
and water supply requirements.
The recessed version of the Series
LFII (TY2234) is intended for use in
areas with finished ceilings. It employs
a two-piece Style 20 Recessed Es-
cutcheon. The Recessed Escutcheon
provides 1/4 inch (6,4 mm) of recessed
adjustment or up to 1/2 inch (12,7 mm)
of total adjustment from the flush ceil-
ing position. The adjustment provided
by the Recessed Escutcheon reduces
the accuracy to which the pipe nipples
to the sprinklers must be cut.
The Series LFII (TY2234) has been
designed with heat sensitivity and
water distribution characteristics
proven to help in the control of residen-
tial fires and to improve the chance for
occupants to escape or be evacuated.
WARNINGS
The Series LF!l (TY2234) Residential
Pendent Sprinklers described herein
must be installed and maintained in
compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation, in addition to the standards of
any other authorities having jurisdic-
tion. Failure to do so may impair the
integrity of these devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
relative to any questions.
Sprinkler/Model
Identification
Number
SIN TY2234
Technical
Data
Approvals:
UL and C-UL Listed.
Maximum Working Pressure:
175 psi (12,1 bar)
Discharge Coefficient:
K = 4.9 GPM/psi112 (70,6 LPM/barll2)
Temperature Rating:
1550F168°C or 1750F/79°C
Finishes:
White Polyester Coated,
Chrome Plated, or Natural Brass
Physical Characteristics:
Frame .............Brass
Button .............Bronze
Sealing Assembly . ..........
Beryllium Nickel w/Teflont
Bulb .........3 mm dia. Glass
Compression Screw .....Bronze
Deflector ...........Bronze
Ejection Spring . . . Stainless Steel
fDuPont Registered Trademark
Operation
The glass Bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass Bulb allowing the sprinkler to
activate and flow water.
Page 1 of 8 JANUARY, 2003 TFP400
Page 20f8 TFP400
Minimum Flow (b) and Minimum Flow (b) and Minimum Flow (b) and
Maximum Maximum Residual Pressure Residual Pressure Residual Pressure
Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling
Area (a) Ft. (Max. 2 Inch Rise (Greater Than 2 Inch Rise (Greater Than 4 inch Rise
Ft. x Ft. (m) for 12 Inch Run) Up To Max. 4 inch Rise for 12 inch Run) Up To Max. 8 Inch Rise for 12 Inch Run)
(m x m) 155"F!68"C or 155°F168°C 175"F/79°C 155"F/68°C 175°F179"C
175°F179"C
12 x 12
(3,7 x 3,7)
12
(3,7)
13 GPM (49,2 LPM)
7.0 psi (0,48 bar)
13 GPM (49,2 LPM)
7.0 psi (0,48 bar)
17 GPM (64,3 LPM)
12.0 psi (0,83 bar)
13 GPM (49,2 LPM)
7.0 psi (0,48 bar)
16 6PM (68,1 LPM)
13.5 psi (0,93 bar)
14 x 14 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM)
(4,3 x 4,3) (4,3) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar)
16 x 16 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM)
(4,9 x 4,9) (4,9) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar)
18 x 18 18 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 23 GPM (87,1 LPM)
(5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 22.0 psi (1,52 bar)
20 x 20 20 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 21 GPM (79,5 LPM) N/A (6,1 x 6,1) (6,1) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 18.4 psi (1.27 bar) I
For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next
highest coverage area for which hydraulic design criteria are stated.
Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated
using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.
TABLE A
NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2234)
RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS
Design
Criteria
The Series LFII (TY2234) Residential
Pendent Sprinklers are UL and C-UL
Listed for installation in accordance
with the following criteria.
NOTE
When conditions exist that are outside
the scope of the provided criteria, refer
to the Residential Sprinkler Design
Guide TFP490 for the manufacturer's
recommendations that may be accept-
able to the localAuthority having Juris-
diction.
System Type. Only wet pipe systems
may be utilized.
Hydraulic Design. The minimum re-
quired sprinkler flow rate for systems
designed to NFPA 13D or NFPA 13R
are given in Table A as a function of
temperature rating and the maximum
allowable coverage areas. The sprin-
kler flow rate is the minimum required
discharge from each of the total
number of "design sprinklers" as speci-
fied in NFPA 13D or NFPA 13R.
For systems designed to NFPA 13, the
number of design sprinklers is to be
the four most hydraulically demanding
sprinklers. The minimum required dis-
charge from each of the four sprinklers
is to be the greater of the following:
The flow rates given in Table A for
NFPA 13D and 13R as a function of
temperature rating and the maxi-
mum allowable coverage area.
A minimum discharge of 0.1 gpm/sq.
ft. over the "design area" comprised
of the four most hydraulically de-
manding sprinklers for the actual
coverage areas being protected by
the four sprinklers.
Obstruction To Water Distribution.
Locations of sprinklers are to be in
accordance with the obstruction rules
of NFPA 13 for residential sprinklers.
Operational Sensitivity. The sprin-
klers are to be installed with a deflector
to ceiling distance of 1-3/8 to 4 inches
or in the recessed position using only
the Style 20 Recessed Escutcheon as
shown in Figure 2.
NOTE
So as to help avoid obstructions to
water distribution, a maximum 12 inch
deflector-to-ceiling distance is permit-
ted for NFPA 130 and NFPA 13Rap-
plications where the sprinklers are lo-
cated in closets.
Sprinkler Spacing. The minimum
spacing between sprinklers is 8 feet
(2,4 m). The maximum spacing be-
tween sprinklers cannot exceed the
length of the coverage area (Ref. Table
A) being hydraulically calculated (e.g.,
maximum 12 feet for a 12 ft. x 12 ft.
coverage area, or 20 feet for a 20 ft. x
20 ft. coverage area).
Beam Ceiling
Design Criteria
The Series LFll (TY2234) Residential
Pendent Sprinklers are UL and C-UL
Listed for installation in residential oc-
cupancies with horizontal ceilings (i.e.,
slopes up to a 2 inch rise over a 12 inch
run) with beams when installed in ac-
cordance with the following criteria:
General Information. The basic con-
cept of this protection scheme is to
locate the sprinklers on the underside
of the beams, Ref. Figure 5, (not in the
beam pockets); to identify the main
beams that principally run in one direc-
tion as "primary beams"; and, to iden-
tify the beams that run principally per-
pendicular to the main beams, as may
be present (or in some cases may be
necessary for proper sprinkler protec-
tion), as "secondary beams".
Primary and Secondary Beam
Types. Solid surface, solid or hollow
core, combustible or non-combustible.
Primary and Secondary Beam Posi-
tioning. Directly attached to the un-
derside of a combustible or non-com-
bustible smooth ceiling at any
elevation.
Primary Beam Cross-Section: Maxi-
mum depth of 14 inches and the maxi-
mum width is unlimited. The cross-sec-
tional shape of the primary beam may
be rectangular to circular.
TFP400 Page 3 of 8
Components:
1 - Frame
Button
Sealing Assembly
Bulb
5 - Compression
Screw
6 - Deflector *
7 - Ejection Spring
* Temperature D
rating is
indicated on 6
Deflector.
7/16(11,1 mm) ,, 1/2 ESCUTCHEON
NOMINAL NP PLATE SEATING
MAKE-IN SURFACE
4
_T. 2-1/4
(57,2 mm)
7
(41.3
1-5/8"
mm)
e
I
-. 2-7/8 DIA.
(73,0 mm)
E921-1
WRENCH STYLE 20
FLATS RECESSED
ESCUTCHEON1
CROSS SECTION PENDENT RECESSED PENDENT
FIGURE 1
SERIES LFII (TY2234) RESIDENTIAL
PENDENT AND RECESSED PENDENT SPRINKLERS
- 2-7/8" DIA. -
(73,0 mm) I 7/16:1/8 1/2(12,7mm) r (11,1:t3,2 mm) 2-1/4" DIA. I 1/4"(6.4mm) I
FACE OF mm)
I SPRINKLER 1572 MOUNTING I FITTING PLATE
_ 1 T_\__
MOUNTING 1/8" SURFACE/
(3.2 mm)
- 1-3/8' (34,9 mm) F CLOSURE 1Y2234 1-1/8(28,6mm)
FIGURE 2
STYLE 20 RECESSED ESCUTCHEON
FOR USE WITH THE SERIES LFII (TY2234)
RESIDENTIAL PENDENT SPRINKLER
Secondary Beam Cross-Section.
Maximum depth to be no greater than
the primary beam and the maximum
width is unlimited. The cross-sectional
shape of the secondary beam may be
rectangular to circular.
/
CH RECESS
(END 'A' USED
FOR 1Y2234)
FIGURE 3
W-TVPE 6
SPRINKLER WRENCH
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 4
V/-TYPE 7 RECESSED
SPRINKLER WRENCH
the primary beam must be placed so
that the beam pockets created by the
primary beams do not exceed 20 feet
in length (Fig. 6B).
NOTE
Primary Beam Spacing. The primary
beams (Fig. 6A) are to be 3 ft. -4 in. to
6 ft. from the compartment wall to cen-
ter of the nearest beam and from cen-
ter to center between beams.
Secondary Beam Spacing. The sec-
ondary beams principally run perpen-
dicular to the primary beams.
Secondary beams of a depth equal to
When the beam pockets created by
the primary beams exceed 20 feet in
length, the installation will require the
use of secondary beams as described
above. Otherwise, secondary beams
need not be present.
Secondary beams of a cross-sectional
depth greater than one-quarter the
depth of the primary beams are to be
a minimum of 3 ft. - 4 in. from the
compartment wall to center of the
nearest beam and from center to cen-
ter between beams (Fig. 6C).
Secondary beams of a cross-sectional
depth no greater than one-quarter the
depth of the primary beams may be
placed at any compartment wall to
center of the nearest beam distance
Page 4 of 8 TFP400
and from any center to center distance
between beams (Fig. 6C).
Lintels. Lintels over doorways exiting
the compartment must be present. The
minimum height for the lintels is 8
inches or no less than the depth of the
Primary Beams, whichever is greater.
Sprinkler Types. Series LFII
(TY2234), 155F and 175F, Pendent
and Recessed Pendent Residential
Sprinklers.
Sprinkler Coverage Area and Hy-
draulic Design. The sprinkler cover-
age areas and hydraulic design criteria
as presented in the Table A for "Hori-
zontal Ceilings" are to be applied.
Sprinkler Position. The deflector to
bottom of primary beams for the Series
LFll (TY2234) Pendent Sprinklers or
Series LFII (TY2234) Recessed Pen-
dent Sprinklers is to be 1-1/4 to 1-3/4
inches (Fig. 5A). The vertical center-
line of the Series LFII (TY2234) Pen-
dent Sprinklers is to be no greater than
half the primary beam cross-sectional
width plus 2 inches from the centerline
of the primary beam (Fig 5B).
NOTES
Core drilling of beams to allow The in-
stallation of sprinkler drops requires
consulting with a structural engineer.
Where core drilling is not permitted,
the previously stated sprinkler position
criteria for the Series LFII (TY2234)
Pendent Sprinklers allows for the
sprinkler drop to be placed adjacent to
The primary beam.
Beam and Soffit Arrangements. A
soffit is permitted to be placed around
the perimeter of a compartment with
the beam arrangement within the sot-
fited area (Fig.7).
The cross-section of the soffit may be
any size as long as it does not create
an obstruction to water distribution per
the obstruction rules of NFPA 13 for
residential sprinklers.
When soffits are present, the pre-
viously provided 3 ft. - 4 in. to 6 ft.
"compartment wall to adjacent beam"
distance for the primary and secon-
dary beams is to be measured from the
face of the soffit as opposed to the
compartment wall.
NOTE
Although the distance to the beams is
measured from The face of The soffit,
the sprinkler coverage area is to be
measured from The compartment wall.
Installation
The Series LFll (TY2234) must be in-
stalled in accordance with the follow-
ing instructions:
NOTES
Do not install any bulb type sprinkler if
The bulb is cracked or there is loss of
liquid from the bulb. With the sprinkler
held horizontally, a small air bubble
should be present. The diameter of The
air bubble is approximately 1/16 inch
(1,6 mm).
A leak tight 1/2 inch NPTsprinklerjoint
should be obtained with a torque of 7
to 14 ft.lbs. (9,5 to 19,0 Nm). A maid-
mum of 21 ft.Ibs. (28,5 Nm) of torque
is to be used to install sprinklers.
Higher levels of torque may distort the
sprinkler inlet with consequent leak-
age or impairment of the sprinkler.
Do not attempt to compensate for in-
sufficient adjustment in an Escutcheon
Plate by under- or over-tightening the
Sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series LFll Pendent Sprinklers
must be installed in accordance with
the following instructions.
Step 1. Pendent sprinklers are to be
installed in the pendent position with
the deflector parallel to the ceiling.
Step 2. With pipe thread sealant ap-
plied to the pipe threads, hand tighten
the sprinkler into the sprinkler fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 3).
With reference to Figure 1, the W-Type
6 Sprinkler Wrench is to be applied to
the wrench flats.
The Series LFlI Recessed Pendent
Sprinklers must be installed in ac-
cordance with the following instruc-
tions.
Step A. Recessed pendent sprinklers
are to be installed in the pendent posi-
tion with the deflector parallel to the
ceiling.
Step B. After installing the Style 20
Mounting Plate over the sprinkler
threads and with pipe thread sealant
applied to the pipe threads, hand
tighten the sprinkler into the sprinkler
fitting.
Step C. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 4). With reference to Figure 1,
the W-Type 7 Recessed Sprinkler
Wrench is to be applied to the sprinkler
wrench flats.
Step D. After the ceiling has been in-
stalled or the finish coat has been ap-
A
Lq 00
TY2234
B
LO W
MAXIMUM TY2234 ONE-HALF BEAM
WIDTH PLUS
2(50.8mm)
FIGURE 5
SPRINKLER POSITIONING
UNDER PRIMARY BEAMS
(Refer to the "Beam Calling
Design Criteria" section)
plied, slide on the Style 20 Closure
over the Series LFll Sprinkler anc
push the Closure over the Mounting
Plate until its flange comes in contact
with the ceiling.
TFP400 Page 5 of 8
ALL FIGURES:
DISTANCES ARE
MEASURED TO
COMPARTMENT
WALL FACES AND
TO CENTERLINES
OF BEAMS
A A A-.l
14" (356 mm)
MAXIMUM
A= 34' to 6-0" (LO to 1.8 m)
FOR PRIMARY BEAMS HAV-
ING A 14" (356 mm) MAXIMUM
DEPTH
PRIMARY
BEAM 20'-0"(6.1 m)
MAXIMUM
COMPARTMENT
WALLS
FIGURE 6A
PRIMARY BEAM SPANS UP TO 20-0" (6.1 m)
-i.. A_ A__-I
IF IF F
SECONDARY
BEAM
PRIMARY
BEAM
COMPARTMENT
WALLS
FIGURE 6B
PRIMARY BEAM SPANS GREATER THAN 20-0(6.1 m)
* PRIMARY
BEAM
*REFER TO
FIGURE 6B COMPARTMENT
FOR SPANS WALLS
EXCEEDING
20-0(6,1 m)
FIGURE 6C
COMBINATIONS OF PRIMARY AND SECONDARY BEAMS
A3-4 10 6-0" (1.0 to 18 m)
FOR PRIMARY BEAMS HAV-
ING A 14"(356 mm) MAXIMUM
DEPTH
B = 20-0 (6.1 m) MAXIMUM
FOR SECONDARY BEAMS
THAT ARE TO BE EQUAL IN
DEPTH TO PRIMARY BEAMS
AND THAT MUST BE IN PLACE
SO THAT PRIMARY BEAM
POCKETS DO NOT EXCEED
20-0(6.1 m)
A = 3-4" 106-0" (1.0101.8 m)
FOR PRIMARY BEAMS HAV-
ING A 14" (356 mm) MAXIMUM
DEPTH
C = Y-4"(1.0 m) MINIMUM FOR
SECONDARY BEAMS HAVING
DEPTHS GREATER THAN 251,16
OF PRIMARY BEAMS
- or—
C =ANY DISTANCE FOR SEC-
ONDARY BEAMS HAVING
DEPTHS UP TO 25% OF
PRIMARY BEAMS
FIGURE 6
BEAM ARRANGEMENTS
(Refer to the "Beam Ceiling Design Criteria" section)
Page 6of8 TFP400
Care and
Maintenance
The Series LFII (1Y2234) must be
maintained and serviced in accord-
ance with the following instructions:
NOTES
Absence of an Escutcheon Plate may
delay the sprinkler operation in a fire
situation.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
which it controls, permission to shut
down the affected fire protection sys-
tem must be obtained from the proper
authorities and all personnel who may
be affected by this action must be no-
tified.
Sprinklers which are found to be leak-
ing or exhibiting visible signs of corro-
sion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler that
has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturer should be contacted relative to
any questions.
NOTE
The owner must assure that the sprin-
klers are not used for hanging of any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster; otherwise, non-
operation in the event of a fire or inad-
vertent operation may result.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service.
TFP400 Page 7 of 8
Limited
Warranty
Products manufactured by Tyco Fire
Products are warranted solely to the
original Buyer for ten (10) years
against defects in material and work-
manship when paid for and properly
installed and maintained under normal
use and service. This warranty will ex-
pire ten (10) years from date of ship-
ment by Tyco Fire Products. No war-
ranty is given for products or
components manufactured by compa-
nies not affiliated by ownership with
Tyco Fire Products or for products and
components which have been subject
to misuse, improper installation, corro-
sion, or which have not been installed,
maintained, modified or repaired in ac-
cordance with applicable Standards of
the National Fire Protection Associa-
tion, and/or the standards of any other
Authorities Having Jurisdiction. Mate-
rials found by Tyco Fire Products to be
defective shall be either repaired or
replaced, at Tyco Fire Products' sole
option. Tyco Fire Products neither as-
sumes, nor authorizes any person to
assume for it, any other obligation in
connection with the sale of products or
parts of products. Tyco Fire Products
shall not be responsible for sprinkler
system design errors or inaccurate or
incomplete information supplied by
Buyer or Buyer's representatives.
IN NO EVENT SHALL TYCO FIRE
PRODUCTS BE LIABLE, IN CON-
TRACT, TORT, STRICT LIABILITY OR
UNDER ANY OTHER LEGAL THE-
ORY, FOR INCIDENTAL, INDIRECT,
SPECIAL OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT
LIMITED TO LABOR CHARGES, RE-
GARDLESS OF WHETHER TYCO
FIRE PRODUCTS WAS INFORMED
ABOUT THE POSSIBILITY OF SUCH
DAMAGES, AND IN NO EVENT
SHALL TYCO FIRE PRODUCTS' LI-
ABILITY EXCEED AN AMOUNT
EQUAL TO THE SALES PRICE.
Ordering
Procedure
When placing an order, indicate the full
product name. Contact your local dis-
tributor for availability..
Sprinkler Assembly:
Series LFII (TY2234), K=4.9, Residen-
tial Pendent Sprinkler with (specify)
temperature rating and (specify) finish,
P/N (specify).
155°F/68C or
Chrome Plated .........P/N 51-201-9-155
155F/68C
White Polyester ........P/N 51-201.4.155
155F/68°C
Natural Brass ..........P/N 51-201-1-155
175Ff79°C or
Chrome Plated .........P/N 51-201.9-175
175F/79C
White Polyester ........P/N 51-201-4-175
175F/79°C
Natural Brass ..........P/N 51-201-1-175
Recessed Escutcheon:
Specify: Style 20 Recessed Escutch-
eon with (specify) finish, P/N (specify).
1/2' (15 mm)
Style 20
Chrome Plated .........P/N 56.705-9-010
1/2' (15 mm)
Style 20
White Color
Coated ...............P/N 56-705-4-010
1/2' (15 mm)
Style 20
Bright Brass
Coated ...............P/N 56-705-2-010
Sprinkler Wrench:
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387.
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001.
Page 8 of 8
tqCO /Fire & Building
I Products
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
A
uxem
Customer Service/Sales:
Tel: (414) 570-5000 / (800) 558-5236
Fax: (414) 570-5010/(800) 877-1295
Series TYFRB - 28, 4.29 5.6,, and 80 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General
Description
The Series TY-FRB, 2.8, 4.2, 5.6, and
8.0 K-factor, Upright and Pendent
Sprinklers described in this data sheet
are quick response - standard cover-
age, decorative 3 mm glass bulb type
spray sprinklers designed for use in
light or ordinary hazard, commercial
occupancies such as banks, hotels,
shopping malls, etc.
The recessed version of the Series
TY-FRB Pendent Sprinkler, where ap-
plicable, is intended for use in areas
with a finished ceiling. It uses either a
two-piece Style 10 (1/2 inch NPT) or
Style 40 (3/4 inch NPT) Recessed Es-
cutcheon with 1/2 inch (12,7 mm) of
recessed adjustment or up to 3/4 inch
(19,1 mm) of total adjustment from the
flush pendent position, or a two-piece
Style 20 (1/2 inch NPT) or Style 30(3/4
inch NPT) Recessed Escutcheon with
1/4 inch (6,4 mm) of recessed adjust-
ment or up to 1/2 inch (12,7 mm) of
total adjustment from the flush pen-
dent position. The adjustment provided
by the Recessed Escutcheon reduces
the accuracy to which the fixed pipe
drops to the sprinklers must be cut.
Corrosion resistant coatings, where
applicable, are utilized to extend the
life of copper alloy sprinklers beyond
that which would otherwise be ob-
tained when exposed to corrosive at-
mospheres. Although corrosion resis-
tant coated sprinklers have passed the
standard corrosion tests of the appli-
cable approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently, it
is recommended that the end user be
consulted with respect to the suitability
of these coatings for any given corro-
sive environment. The effects of ambi-
ent temperature, concentration of
chemicals, and gas/chemical velocity,
should be considered, as a minimum,
along with the corrosive nature of the
Page 1 of 8
chemical to which the sprinklers will be
exposed.
An intermediate level versions of the
Series TY-FRB Pendent Sprinklers are
detailed in Technical Data Sheet
TFP356, and Sprinkler Guards are de-
tailed in Technical Data Sheet TFP780
WARNINGS
The Series TY-FRB Sprinklers de-
scribed herein must be installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the integrity of these devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
relative to any questions.
Model/Sprinkler
Identification
Numbers
TY1131 - Upright 2.8K, 1/2"NPT
TY1231 - Pendent 2.8K, 1/2"NPT
TY2131 - Upright 4.2K, 1/2"NPT
TY2231 - Pendent 4.2K, 1/2"NPT
TY3131 - Upright 5.6K, 1/2"NPT
TY3231 - Pendent 5.6K, 1/2"NPT
TY4131 - Upright 8.0K, 3/4'NPT
TY4231 - Pendent 8.0K, 3/4"NPT
Technical
Data
Approvals
UL and C-UL Listed.
FM, LPCB, and NYC Approved.
(Refer to Table A for complete approval
information including corrosion resis-
tant status.)
APRIL, 2003
...
Maximum Working Pressure
175 psi (12,1 bar)
Discharge Coefficient
K = 2.8 GPM/psil/2 (40,3 LPMlbar1I2)
K = 4.2 GPM/ps1112 (60,5 LPM/barl/2)
K = 5.6 GPM/psill2 (80,6 LPM/bar1/2)
K = 8.0 GPM/psi112 (115,2 LPM/bar112)
Temperature Ratings
Refer to Table A and B
Finishes
Sprinkler: Refer to Table A and B
Recessed Escutcheon: White Coated,
Chrome Plated, or Brass Plated
Physical Characteristics
Frame ............Bronze
Button ........Brass/Copper
Sealing Assembly ..........
Beryllium Nickel w/Teflont
Bulb ..............Glass
Compression Screw . . .. . Bronze
Deflector .......Copper/Bronze
Bushing (K=2.8) .......Bronze
TFPI7I
ESCUTCHEON
PLATE SEATING
SURFACE 1/2" **
NPT
T-
2-3/16"
(55,6 mm) 1
El I
Page 2 of 8
ESCUTCHEON 7/16(11,1 mm) STYLE 10or20
2-1/4, \—
PLATE SEATING 1/2 ** NOMINAL
SURFACE NPT MAKE-IN ESCUTCHEON
RECESSED
(57,2 mm)
"WRENCH
FLATS
2-7/8' (73,0 mm) DIA.
RECESSED PENDENT
TFPI7I
SSU *
DEFLECTOR
5 7/16"
(11,1mm) I 4
NOMINAL I
MAKE-IN 2
2-3/16" 3
(55,6 mm)
7
1/2" NPT** 1
UPRIGHT CROSS SECTION
SSP DEFLECTOR *
PENDENT
1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to
2- Button Assembly 5 - Compression 7- Bushing orifice seat on frame.
Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 1
QUICK RESPONSE SERIES 7Y-FRB UPRIGHT (TYI13I) AND PENDENT (TY1231) SPRINKLERS
2.8 K-FACTOR, 1/2 INCH NPT
7/16"(11,1 mm) STYLE 100r20
NOMINAL RECESSED SSU*
MAKE-IN ESCUTCHEON DEFLECTOR
49~
J1:rFLATS
J111T1\ (11.1 mm) I
NOMINAL I
/7/16
I
MAKE-IN
2-3/16"
(55,6 mm)
1/2" NPT**
UPRIGHT CROSS SECTION
SSP DEFLECTOR* H— 2-7/8"(73,0 mm) DIA. -
PENDENT RECESSED PENDENT
1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression orifice seat on frame.
Screw **Pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 2
QUICK RESPONSE SERIES TY-FRB UPRIGHT(TV2131) AND PENDENT(TY2231) SPRINKLERS
4.2 K-FACTOR, 1/2 INCH NPT
STYLE 30 or 40
RECESSED SSU* ESCUTCHEON DEFLECTOR
UPRIGHT
WRENCH
FLATS
_J
-7/8° (73,0 mm) DIA.
ESSED PENDENT
ESCUTCHEON 1/2(12,7mm)
PLATE SEATING 3/4fl ** NOMINAL
SURFACE NPT MAKE-IN
T
-
1
2-5/16'
(58,7 mm)
1-9/16' I (39,7 mm)
SSP DEFLECTOR *
PENDENT REC
6*
1/2"
(12,7 mm)
NOMINAL I
. : MAKE-IN
2-1/4°
____ 57,2 mm) ,, 3
____________
(
'•
1
3/4 NPT' t
CROSS SECTION
TFPI7I Page 3 of 8
ESCUTCHEON 7/16 (11,1 mm) STYLE 100r20
PLATE SEATING 1/2 ** NOMINAL RECESSED
SURFACE MAKE-IN ESCUTCHEON NPT DEFLECTOR
___
__
6*
7/16°
2-3/16° 1,1 mm)
_______ NOMINAL (55,6 mm)
______ __________
______
______
16" 2
MAKE-IN
(38,1 mm) _______
1.1/2u 2-3/
WRENC _______ mm) - 3 FLATS
SSP DEFLECTOR* 2-7/8 (73,0 mm) DIA. 1/2" NPT**
PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION
- Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression orifice seat on frame. Screw **pp thread connections per ISO 7/1 can be provided on
special request.
FIGURE 3
QUICK RESPONSE SERIES. TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT
1 - Frame 3- Sealing 4. Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to
2 - Button Assembly 5 - Compression orifice seat on frame. Screw **pipe thread connections per ISO 7/1 can be provided on
special request.
FIGURE 4
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TV4231) SPRINKLERS
8.0 K-FACTOR, 3/4 INCH NPT
Operation
The glass Bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass Bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The Series TY-FRB Pendent and Up-
right Sprinklers are intended for fire
protection systems designed in ac-
cordance with the standard installation
rules recognized by the applicable
Listing or Approval agency (e.g., UL
Listing is based on the requirements of
NFPA 13, and FM Approval is based
on the requirements of FM's Loss Pre-
vention Data Sheets ). Only the Style
10, 20, 30, or 40 Recessed Escutch-
eon, as applicable, is to be used for
recessed pendent installations.
Page 4 of 8
SPRINKLER FINISH (See Note 7)
K TYPE TEMP. BULB
LIQUID
NATURAL
BRASS
CHROME
PLATED
I WHITE...
IPOLYESTER
2.8
1/2
PENDENT
(TY1231)
and
UPRIGHT
(TY1131)
135°F/57°C Orange
123,5
155'F/68°C Red
175°F/79°C Yellow
200'F/93°C Green
286'F/141°C Blue
NPT
RECESSED
PENDENT
(TY2231)'
Figure 5
135'F/57°C Orange
1,21 5
155°F/68°C Red
175°F/79°C Yellow
200°F/93'C Green
RECESSED
PENDENT
(TY2231)"
Figure 6
135°F/57'C Orange
155'F/68°C Red
175°F/79°C Yellow
200°F193'C Green
4.2
1/2
NPT
PENDENT
(TY2231)
and
UPRIGHT
(1Y3131)
135°F/57°C Orange
1,2
155'F/68°C Red
175"F/79°C Yellow
200°F/93'C Green
286°F/141'C Blue
RECESSED
PENDENT
(TY2231)'
Figure 7
1351F/571C Orange
155°F/68'C Red
175°F179°C Yellow
200°F/93°C Green
RECESSED
PENDENT
(TY2231)"
Figure 8
135'F/57°C Orange
155°F/68'C Red
175°F/79°C Yellow
200'F193'C Green
NOTES:
Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response
Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin-
klers.
5. Approved by the City of New York under MEA 354-01 -E.
7. Where Polyester Coated Sprinklers are noted to be UL and C.UL Listed, the sprin-
klers are UL and C-UL Listed as Corrosion Resistant Sprinklers.
Installed with Style 10 (1/2' NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment Re-
cessed Escutcheon, as applicable.
Installed with Style 20(1/2" NPT) or Style 30 (3/4' NPT) 1/2' Total Adjustment Re-
cessed Escutcheon, as applicable. -
'"Frame and Deflector only. Listings and approvals apply to all colors (Special Order).
N/A: Not Available
TABLE A
LABORATORY LISTINGS AND APPROVALS
2.8 AND 4.2 K-FACTOR SPRINKLERS
TFPI7I
Installation
The Series TY-FRB Sprinklers must be
installed in accordance with the follow-
ing instructions:
NOTES
Do not install any bulb type sprinkler if
the bulb is cracked or There is a loss of
liquid from the bulb. With the sprinkler
held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F/570C to 3/32
inch (2,4 mm) for the 286°F/14 1°C
temperature ratings.
A leak tight 1/2 inch NPTsprinkler joint
should be obtained with a torque of 7
to 14 ft. lbs. (9,5 to 19,0 Nm). A maxi-
mum of 21 ft. lbs. (28,5 Nm) of torque
may be used to install sprinklers with
1/2 NPT connections. A leak tight 3/4
inch NPT sprinkler joint should be ob-
tained with a torque of 10 to 20 ft lbs.
(13,4 to 26,8 Nm). A maximum of 30
ft lbs. (40,7 Nm) of torque is to be used
to install sprinklers with 3/4 NPT con-
nections. Higher levels of torque may
distort the sprinkler inlet and cause
leakage or impairment of the sprinkler.
Do not attempt to make-up for insuffi-
cient adjustment in the escutcheon
plate by under- or over-tightening the
sprinkler. Readjust the position of the
sprinkler fitting to suit.
The Series TY-FRB Pendent and Up-
right Sprinklers must be installed in
accordance with the following instruc-
tions.
Step 1. Pendent sprinklers are to be
installed in the pendent position, and
upright sprinklers are to be installed in
the upright position.
Step 2. With pipe thread sealant ap-
plied to the pipe threads, hand tighten
the sprinkler into the sprinkler fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 13).
With reference to Figures 1, 2, 3, and
4, the W-Type 6 Sprinkler Wrench is to
be applied to the sprinkler wrench
flats.
The Series TY-FRB Recessed Pen-
dent Sprinklers must be installed in
accordance with the following instruc-
tions.
Step A. After installing the Style 10.
20, 30, or 40 Mounting Plate, as appli-
cable, over the sprinkler threads and
with pipe thread sealant applied to the
pipe threads, hand tighten the sprin-
kler into the sprinkler fitting.
Step B. Tighten the sprinkler into the
'I
TFPI7I Page 5 of 8
SPRINKLER FINISH (See Note 7)
K TYPE . TEMP. BULB NATURAL I CHROME I WHITE*** LEAD
LIQUID BRASS I PLATED IPOLYESTER COATED
135°F/57°C Orange
PENDENT
(TY3231)
and
12345,6 1,23,5 155°F/68°C Red
175°F/79°C Yellow
UPRIGHT 200°F/93°C Green
5.6 (TY3131) 286°F/141°C Blue
1/2°
NPT 135°F/57°C Orange
RECESSED
PENDENT 1, 2,4,5 N/A 155°F/68°C Red
175°F/79°C Yellow (TY3231)
Figure 9 200°F/93°C Green
135°F/57°C Orange I
RECESSED
PENDENT
(TY3231)°°
1, 2, 3,4,5
I I I 1, 2, 4, 5
I
N/A 155°F/68°C Red
175°F/79°C Yellow
Figure 10 200°F/93°C Green
135°F/57°C Orange
PENDENT
(TY4231) / 1,2,5 155°F/68°C Red
175°F/79°C Yellow and 1,2,3,4,5,6
200°F/93°C Green UPRIGHT
8.0
3/4°
(TY4131) 286°F/141°C Blue
NPT 135°F/57°C Green
RECESSED
PENDENT
(TY4231)°
1,2, 4, 5 N/A
155°F/68°C Orange
175°F/79°C Red
Figure 11 200°F/93°C Yellow
135°F/57°C Orange
RECESSED
PENDENT 1,2, 34,5 N/A
155°F/68°C Red
175°F/79°C Yellow (1Y4231)°°
Figure 12 200°F/93°C Green
NOTES:
Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the Loss Prevention Certification Board (LPCB) as Quick Response Sprinklers; however, the LPC does not rate the thermal
sensitivity of recessed sprinklers.
Approved by the City of New York under MEA 354-01-E.
VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428.3377).
Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as
Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a
Corrosion Resistant Sprinklers.
* Installed with Style 10 (1/2' NPT) or Style 40 (3/4° NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20 (1/2° NPT) or Style 30 (3/4° NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only. Listings and approvals apply to all colors (Special Order).
N/A: Not Available
TABLE B
LABORATORY LISTINGS AND APPROVALS
5.6 AND 8.0 K-FACTOR SPRINKLERS
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 14). With reference to Figure 1,
2, 3, and 4, the W-Type 7 Recessed
Sprinkler Wrench is to be applied to
the sprinkler wrench flats.
Step C. After the ceiling has been in-
stalled or the finish coat has been ap-
plied, slide on the Style 10, 20, 30, or
40 Closure over the Series TY-FRB
Sprinkler and push the Closure over
the Mounting Plate until its flange
comes in contact with the ceiling.
Page 6 of 8
- 2-7/8" DIA.
(73.0 mm) I 3/4' (19.1 mm) 5/8±1/4
(15.9±6.4 mm) - 2-1/4" DIA. I 1/4(6.4mm) I
FACE OF MOUNTING
PLATE I
FITTING
1/8' I
SPRINKLER
I
(3,2 mm)
MOUNTING
SURFACE/
CLOSURE SERIES 1-5/16' (33.3 mm)
TY-FRB 13/16"(20.6 mm)
FIGURE 5
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT
- 2-7/8' DIA. -
5/8±1/4
(73.0 mm) I 3/4'(19.1 mm)
(15.9±6.4mm) 2-1/4 DIA. I 1/4"(6.4mm)
I MOU I FACE OF WING I PLAT I SPRINKLER E
FITTING
1/8
Owl I MM)
MOUNTING/
SURFACE
SERIES 1-1/4__(31,8 mm) CLOSURE TY-FRB 3/4' (19.1 mm)
FIGURE 7
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT
TFPI7I
- 2-7/8' DIA. -
(73.0 mm) I 1/2±1/8' I 1/2'(12.7mm) r (12,7±3.2 mm) 2-1/4' DIA. 1/4' (6,4 mm) I
I SPRINKLER PLATE I
I FACE OF 'Z57.2 mm) MOUNTING I
I
FITTING
1/8'
MOUNTING
(2mm)
t \
SURFACE
1-5/16'(33,3 mm) CLOSURE SERIES ____________
TY-FRB 1-1/16"(27.0 mm)
FIGURE 6
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 INCH NPT
- 2-7/8' DIA. -
(73,0 mm) I 1/2"(12.7 mm r (12.7±3.2 mm) 2-1/4' DIA. 1/4' (6.4 mm) I
IFACE OF MOUNTING I (57.2 mm)
PLATE I SPRINKLER
FITTING
/ MOUNTING
SURFACE
/1 — I
CLOSURE SERIES 1-1/4"(31.8 mm)I
TY-FRB 1"(25,4 mm)
FIGURE 8
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 INCH NPT
i
Care and
Maintenance
The Series TY-FRB Sprinklers must be
maintained and serviced in accord-
ance with the following instructions:
NOTES
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shutdown the
affected fire protection system must be
obtained from the proper authorities
and all personnel who maybe affected
by this action must be notified.
Absence of an escutcheon, which is
used to cover a clearance hole, may
delay the time to sprinkler operation in
a fire situation.
Sprinklers that are found to be leaking
or exhibiting visible signs of corrosion
must be replaced.
Automatic sprinklers must never be
painted, plated, coated or otherwise
altered after leaving the factory. Modi-
fied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers - before, during,
and after installation. Sprinklers dam-
aged by dropping, striking, wrench
twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler that
has a cracked bulb or that has lost
liquid from its bulb. (Ref. Installation
Section).
Frequent visual inspections are rec-
ommended to be initially, performed for
corrosion resistant coated sprinklers,
after the installation has been com-
pleted, to verify the integrity of the cor-
rosion resistant coating. Thereafter,
annual inspections per NFPA 25
should suffice; however, instead of in-
specting from the floor level, a random
sampling of close-up visual inspec-
tions should be made, so as to better
determine the exact sprinkler condi-
TFPI7I
- 2-7/8" DIA. -
5/8±1/4 (73.0 mm) I 3/4(19.1 mm)
(15.9±6,4 mm) 2-1/4" DIA. I 1/4(6.4mm) I
I FACE OF MOUNTING I I SPRINKLER PLATE
FITTING
1/8"
1
MOUNTING,
,
,,/" - SURFACE
SERIES 1-1/4(31,8mm) CLOSURE TY.FRB 3/4(19.1 mm)
FIGURE 9
SERIES TY-FRB RECESSED PENDENT
WITH P4(0-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
- 2-7/8" DIA. -
5/8±1/4" (73.0 mm) I 3/4(19.1 mm)
(15.9±6.4 mm) 2.1/4" DIA. 1/4"(6.4 mm)
FACE OF (57.2 MOUNTING
PLATE
FITTING
SPRINKLER
(3.21 mm)
MOUNTING
SURFACE/
CLOSURE SERIES 1-5/16-o
TY-FRB 13/16" (20,6 mm)
FIGURE 11
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
Page 7 of 8
- 2-7/8" DIA. -
1/2±1/8" (73.0 mm) 1/2(12,7mm) r (12.7±3.2 mm) 2-1/4" DIA. J 1/4" (6.4 mm) I
I I FACE OF .2 57 mm) MOUNTING
SPRINKLER PLATE I
I FITTING
f \
MOUNTING
SURFACE
SERIES 1.1/4" (31.8 mm) CLOSURE TYFRB 1" (25.4 mm)
FIGURE 10
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 INCH NPT
- 2-7/8" DIA. -I
1/2±1/8" (73.0 mm) I 1/2(12.7mm)
r (12.7±32 mm) 2-1/4" DIA. 1/4"(6.4 mm)
I FACE OF (57.2 I MOUNTING I
I SPRINKLER PLATE I I FITTING 1/8" I I
____
__ _____________
(3.2 mm)
T-7- MOUNTING MOUNTING
SURFACE
CLOSURE SERIES 1.5/16" (33.3 mm)f
TYFRB 1-1/16" (27.0 mm)
FIGURE 12
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 INCH NPT
tion and the long term integrity of the
corrosion resistant coating, as it may
be affected by the corrosive conditions
present.
The owner is responsible for the in-
spection, testing, and maintenance of
their fire protection system and de-
vices in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Protec-
tion Association (e.g., NFPA 25), in
addition to the standards of any other
authorities having jurisdiction. The in-
stalling contractor or sprinkler manu-
facturer should be contacted relative to
any questions.
It is recommended that automatic
sprinkler systems be inspected,
tested, and maintained by a qualified
Inspection Service.
WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)
WRENCH RECESS
(END "5" USED FOR
3/4' NPT MODELS)
FIGURE 13
W- TYPE 6 SPRINKLER
WRENCH
WRENCH
RECESS
ft
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 14
W-TYPE 7 RECESSED
SPRINKLER WRENCH
Page 8 of 8 TFPI7I
P/N 57-XXX-X-XXX
I I
- MODEL/SIN -
330 2.8K UPRIGHT (1/2°NPT) TY1131
331 2.8K PENDENT (1/2'NPT) 1Y1231
340 4.2K UPRIGHT (1/2'NPT) TY2131
341 4.2K PENDENT (1/2"NPT) 1Y2231
370 5.6K UPRIGHT (1/2°NPT) TY3131
371 5.6K PENDENT (1/2°NPT) 1Y3231
390 8.0K UPRIGHT (3/4"NPT) TY4131
391 8.0K PENDENT (3/4'NPT) TY4231
I I
I SPRINKLER
L 135
1 NATURAL BRASS
4 WHITE POLYESTER
9 CHROME PLATED
7 LEAD COATED
I
155
175
200
286
RATING
TEMPERATUF
155°F168°C
175°FF79'C
200°F/93°C
286'F/141C
TABLE C
PART NUMBER SELECTION
SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS
Limited
Warranty
Products manufactured by Tyco Fire
Products are warranted solely to the
original Buyer for ten (10) years
against defects in material and work-
manship when paid for and properly
installed and maintained under normal
use and service. This warranty will ex-
pire ten (10) years from date of ship-
ment by Tyco Fire Products. No war-
ranty is given for products or
components manufactured by compa-
nies not affiliated by ownership with
Tyco Fire Products or for products and
components which have been subject
to misuse, improper installation, corro-
sion, or which have not been installed,
maintained, modified or repaired in ac-
cordance with applicable Standards of
the National Fire Protection Associa-
tion, and/or the standards of any other
Authorities Having Jurisdiction. Mate-
rials found by Tyco Fire Products to be
defective shall be either repaired or
replaced, at Tyco Fire Products' sole
option. Tyco Fire Products neither as-
sumes, nor authorizes any person to
assume for it, any other obligation in
connection with the sale of products or
parts of products. Tyco Fire Products
shall not be responsible for sprinkler
system design errors or inaccurate or
incomplete information supplied by
Buyer or Buyer's representatives.
IN NO EVENT SHALL TYCO FIRE
PRODUCTS BE LIABLE, IN CON-
TRACT, TORT, STRICT LIABILITY OR
UNDER ANY OTHER LEGAL THE-
ORY, FOR INCIDENTAL, INDIRECT,
SPECIAL OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT
LIMITED TO LABOR CHARGES, RE-
GARDLESS OF WHETHER TYCO
FIRE PRODUCTS WAS INFORMED
ABOUT THE POSSIBILITY OF SUCH
DAMAGES, AND IN NO EVENT
SHALL TYCO FIRE PRODUCTS' LI-
ABILITY EXCEED AN AMOUNT
EQUAL TO THE SALES PRICE.
THE FOREGOING WARRANTY IS
MADE IN LIEU OF ANY AND ALL
OTHER WARRANTIES EXPRESS-OR
Ordering
Procedure
When placing an order, indicate the full
product name. Refer to the Price List
for complete listing of Part Numbers.
Contact your local distributor for avail-
ability.
Sprinkler Assemblies with NPT
Thread Connections:
Specify: (Specify Model/SIN), Quick
Response, (specify K-factor), (specify
temperature rating), Series TY-FRB
(specify Pendent or Upright) Sprinkler
with (specify type of finish or coating),
P/N (specify from Table C).
Recessed Escutcheon:
Specify: Style (specify) Recessed Es-
cutcheon with (specify finish), P/N
(specify).
1/2 (15 mm)
Style 10
Chrome Plated .........P/N 56-701-9-010
1/2' (15 mm)
Style 10
White Color
Coated ................P/N 56.701.4.010
1/2' (15 mm)
Style 10
Brass Plated ...........P/N 56-701-2-010
1/2' (15 mm)
Style 20
Chrome Plated .........P/N 56-705-9-010
1/2' (15 mm)
Style 20
White Color
Coated ................P/N 56-705-4-010
1/2 (15 mm)
Style 20
Brass Plated ...........PIN 56-705-2-010
3/4' (20 mm)
Style 30
Chrome Plated .........P/N 56.705-9-011
3/4 (20 mm)
Style 30
White Color
Coated ................P/N 56-705-4-011
3/4" (20 mm)
Style 30
Brass Plated ...........P/N 56-705-2-011
3/4" (20 mm)
Style 40
Chrome Plated .........P/N 56-700-9-010
3/4" (20 mm)
Style 40
White Color
Coated ................P/N 56-700-4-010
3/4' (20 mm)
Style 40
Brass Plated ...........P/N 56-700-2-010
Sprinkler Wrench:
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387.
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001.
TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446
I I
tqCD Flo/w / Tyco Fire
I Control I Products
BlazeMaster'
FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET
TWO FIRE PRODUCTS
451 North Cannon Avenue
Lansdale, Pennsylvania 19446
wwwtyco-flrecom
TEcHNicaL SENWCNi
TEL. (800) 381-9312 FAx (800) 791-5500
E.dw4n: techsen4 tycofp.com
I
No. 19-1.5 tDu8
4-1.1.20
9/2001
90° Elbow
Fittings
45° Elbow
TO
TO Reducing
900 Elbow
Tee Cross Reducing
Cross
-if
r slntrethtctlone8xere .e ,o e
41Qn1 $fc4yco$i,e Products (TFP) BlazeMaster CPVC pipe and prAft fterf heat resistance and
fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping
automatic fire sprinkler systems. They are made from a materials used in the plumbing trade. Various adapters are
specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping. All female
post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability.
the art additives. TFP BIazeMaster CPVC products are Grooved adapters connect directly to grooved end valves
easier to install than traditional steel pipe systems, and at and metallic pipe, with flexible grooved end couplings.
Technical Data
Sizes: '6" - 3 Manufacture Source: U.S.A.
Maximum Working Pressure: 115 psi Material: Approvals UL, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5
MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and
Note: See aantTFP BlazeMeeter Installation bistnicbons and ASTM F439 (Sch. 80)
Tedinicml Manual, for exert lislinujappiwal infon'natlon Color: Orange
Plue
Nom.Pipe Size Avg. O.B. Inches Avg. I.D. Inches Wt. ths,/Ft. WI. HaD filled Pipe Lbsjlt. Ft. of Pipe per Lift WI. per LIft Lbs.
3/4' 1.050 0.874 0.17 0.43 7875 1413 V. 1.315 1.101 0.26 0.67 5040 1320
1.660 1.394 0.42 1.07 2835 1191
1'!2" 1.900 1.598 0.55 1.40 2205 1136
20 2.375 2.003 1 0.86 2.20 1260 1063
2 Y2" 2.875 2.423 1.26 3.22 1215 1531
3' 3.500 2.952 1.87 4.79 720 1344
Part No. Size Sch. T/O Wt.
80050 340 40 '/e" 0.08 lb.
80051 1" 40 '/e' 0.11 lb.
80052 1114" 40 3/40 0.20 lb.
80053 1 1V' 80 1 7/,," 0.31 lb.
80054 20 80 3/
4
0 0.56 lb.
80055 21/2' 80 3/40 0.89 lb.
80056 30 80 1" 1.19 lb.
iPart
I No.1
I
i Size I Sch. I
I T/O I Wt. l
I I 1112
180032 1' x 3/401 40 I i'' I i3/ I 0.161
Part No. -
Size
-
Sch. T/O Wt.
80025 '6" 40 '/i.' 0.09 lb.
80026 40 3/40 0.14 lb.
80027 - 1114" 40 - 6" 0.21 lb.
80028 1 i'i' 80 1 Vhel 0.40 lb.
80029 80 1'4' 0.79 lb.
80030 2½" 80 -
11/20 1.14 lb.
80031 80 V'/,,' i.82 lb.
Part No. Size - Sch.
- T/O Wt.
80000 14' 40 1 'I." 0.11 lb.
80001 1' 40 3/
4
0 0.19 lb.
80002 1'/4" 40 '/' 0.26 lb.
80003 1 VI,' 80 1" 1 0.51 lb.
80004 2" 80 1',,' 0.90 lb.
80005 2'!2' 80 i'/,e" 1.59 lb.
80006 3' 80 1 111/." 2.41 lb.
'Part'
I No. I Size l
I lSch.
I T/O Wt. I I lb. I I I 1 ' I 2
180015 10x '/'I 40 I "ii.' "/,e' 10.28
Part No. Size Sch. T/O Wt.
80009 /4" 40 °/." 0.13 lb.
80010 40 '/." 0.23 lb.
80011 11/4" 40 "I,,' 0.34 lb.
80012 1½' 80 1 1'/.' 0.67 lb.
80013 80 13!." 1.00 lb.
80014 21 I" 80 1°/is ' lb.
80008 3' 80 1"Ii.' E2.89 lb.
T
Reducer -.
Bushing
Part No. Size Sch. I 1/0 WI.
80200 1"x 3/4 " 40 '/.° 0.04 lb.
80201 11/40 x 34" 40 '/,e° 0.11 lb.
80202 11/4" x 1" 40'/is" 0.12 lb.
80203 1W X 36° 80 5W 0.16 lb.
80204 1 1/20 x 10 80 W 0.14 1b.
80205 11/2" X 11/40 80 '/e" 0.17 lb.
80206 2" x '/" 80 34" 0.27 lb.
80207 2"x 1" 80 "be° 0.26 lb.
80208 x V/i' 80 8/0 0.24 lb.
80209 20 x V/2" 80 7/ie 0.19 lb.
80215 21/20 x 10 80 V'/ie° 0.42 lb.
80214 21/" X 11/4" 80 16" 0.45 lb.
80213 21/2" X 1'/2" 80 16/. 0.46 lb.
80211 211? x 2" 80 V/ic0 0.29 lb.
80210 X 2° 80 2'/te" 0.72 lb.
80212 3" x 2'/2" 80 VVie" 0.47 lb.
tvow
Reducing '°
Tee
-r-°
Coupling
-'-E1E+- Cap
Part Nol Size Sch T/O Wt.
80075 3/4° 40 Von 0.07 lb.
80076 1° 40 I/fl 0.11 lb.
80077 11/4° 40 '/e° 0.12 lb.
80078 'P/° 80 3/0 0.25 lb.
80079 2° 80 '/e° 0.38 lb.
80080 2'/° 80 3/is 0.67 lb.
80081 1 3 80 '/." 0.91 lb.
Grooved
Coupling
-.CH IPipe 0.0.
Adapter
Part No. Size Sch. T/O Wt. Pipe CD
80160 11/4° x 11/4° Grooved 40 2 0.78 lb. 11/40 (1.660")
80161 11/20 x V/i' Grooved 80 2 /is" 0,95 lb. 11/2' (1.900")
80162 20 x 2° Grooved 80 2 V18° 1.42 lb. 2'(2.375')
80163 21/" x 21/" Grooved 80 2 '/° 2.28 lb. 21/2 (2.875")
80164 30 x 3" Grooved 80 2114° 3.00 lb. 3'(3.500')
80168 3° x 78.1 mm Grooved 80 2'I4" 2.72 lb. I 76.1mm (3.000")
Part No. Size Sch T/O Wt
80100 'I' 40 6/, 0.04 lb.
80101 1" 40 3/0 0.06 1b.
80102 11/4" 40 V° 0.10 lb.
80103 11/20 80 6/80 0.20 1b.
80104 2° 801 /° 0.31 lb.
80105 21/2° 80 '/e" 0.58 lb.
80106 3" 80 10 0.88 1b.
T/O
Female
Adapter
Part No. Size Sch. T/O Wt.
80142 3/4 x 3/40 NPT 40 Vi' 0.41 lb.
80145 1"x 1" NPT 40 '/i' 0.63 lb.
80146 V/i' X 11/4" NPT 1 40 7/co 1.03 lb.
80147 V/i' X V/a" NPT 80 10 1.42 lb.
80148 20 x 2" NPT 1 80 131.0 2.66 lb.
TiO
Male -.-
Adapter
Part No. Size Sch. I T/O I Wt
80157 36° x 340 NPT 40 1 V/i.° 0.33 lb.
I 80158 10x 10 NPT 40 1 11." 1 0.56 lb.
Tb
Reducing .-...-
Coupling
Part No. Size I Sch. 1/0 I WI.
80220 1°x 3/
4
0 40 1 1/80 1 0.08 lb.
Part
No. Size - Sch. T/O Wt
lb. '7 1 i 3
80132 3/40 x 3/40 X 10 40 I4° 1 '/° Ve" 0.14
80133 x Vi' x 360 40 '/,° 1 /ie° 'Ii' 0.14
80134 10 x 3/4's x 1" 40 '4" 3/4"3/4 0.17
80260 1° x 1° x 3/4 40 '1° 3/
4
0 hl/t60 0.16
80135 11/4" x 1" x 3/0 40 'lie" /4° e/i. 0.21
80136 11/4° x 1" x 1" 40 - "/is" 3/40
- 'he" - 0.22
80137 11/4" x 1" x V/i' 40 'Vi." i8/" 13/i3O
-
0.26
80261 11/4" X 11I4I X 3/4" 40 6/0 6/i" '/e° 0.23
80262 11/4° x 11/4° x 10 40 5/40 3/40 7/ 0.26
80138 11/4" x 11/4" x 11/20 80 - in - 1° - 1° - 0.43
80140 1V2° x 11/40 x 36" 80 1/2' 8/c" 1" 0,36
80141 11/° x 11/4" x 10 80 1/2" 64" 11/80 0.38
80263 1/2 X 11/20 X /4° 80 0/0 9/' 10 0.36
80264 11/2" x 11/2" x 1" 80 /° 6/0 10 038
80275 11/20 x 11/20 X 11/4° 80 '/e"
7/0 1" 0.45
80265 2"! 2" x 3/40 80 '/° 3/
4
0 i'/e° 0.61
80266 2"x2" x 1" 80 '/e° '1° 1'/° 066
80274 x 2° x 11/4° 80 10 1" 13/co 074
80267 2" x 2" x 11/2" 80 1½" i'I." 13/eu 0.78
80271 21/2" x 21/2" x 1° 80 i"It." 1"l.°" i!./ie° 1.43
80272 21/2° X 21/20 X V/i' 80 1 '!,.'1 V1/ie" 10/18" 1.46
80273 21/2" X 21/2" x 111" 80 111/leo 1 hI/,0 1/i.° 1.48
80276 21/2" x 21/2" x 2" 80 1"/,." 11'/i." 1 Vie" 1.50
80270 x 3°x V/i' 80 1'/4" i'14° 1"!,.' 2.28
80268 T x x 2° 80 13I4° 13/4° 13/4" 2.25
802691.30 x 3° x 21I2" 1 80 1'/4° 1'I4° V6/ie° 2.44
Part No. I Size Sch. T/O Wt.
80175E 3/40 x 1/2° NPT 80 7/,o" 0.20 lb.
80176E 1° x 1/2° NPT 80 '/'o° 0.22 lb.
80177WL 3/4" X 1/2"NPT 40 0 0/4 0.16 lb.
80179 1 x 3/4° NPT 40 3/40 0.43 lb.
Sprinkler Head Adapter
(Spigot)
with Brass Threaded Insert
Part No. Size Sch. T/O Wt.
80175W 3/4° x 'I? NPT 40 0.19 lb.
80176W 1° x '/° NPT 40 'Ito" 0.18 lb.
Back-to-Back Cross
with Brass Threaded Insert
Sprinkler Head Adapter
with Brass Threaded Insert _______
Sprinkler Head Adapter
with Brass Threaded Insert Ek
I Part No. Size Sch. T/O Wt.
I 80177L 3/4 x 1/2° NPT 40 /2° 0.16 lb.
80178 1" x 1/20 NPT 40 /2° 0.20 lb.
Part
No. Size 8th. T/O Wt.
lb. 1 1 2
80462 1" x 1° x '/° NPT x 'k" NPT 40 %IJ 1 '/" 0.46
80463 1" x 1" x 1/2" NPT x '/" NPT 40 W 1 1118' 0.47
Sprinkler Head Adapter
900 Elbow
with Brass Threaded Insert Back-to-Back Tee
with Brass Threaded Insert
I Part• I I No.
I I Size I I Sch.
I i/O Wt. I
I lb. I I 1 I 2
I 80199 I /.° X /2° NPT I I 6/' I 'i,.° I 0.20 I
I 80189 I 1" X /2° NPT 1 40 I V/io° I 0.26 I
Sprinkler Head Adapter —I
Tee —. .
_____
with Brass Threaded Insert
TIOLl -lu-ol TIC?
Part Size Wt.
No.
Sch.
lb. 1 j42
80459
80460
_1"x 1/2'NPTx '/°NPT
1° x 1/20 NPT x l/ NPT
_40
40
_"e°
/to
/_1°/i."_0.48
1 '/." 0.46
Part
No. Size Sch. T/O Wt
lb. 1 - 1 2 - 3
80250 3/4"x 3/4"x '/'NPT 40 /' 1" 0.22
80251 1"x1°x '/°NPT 40 "/.° "/,° 13/U 0.29
80249 1°x1°x1"NPT 40 to/lou 16/10,1 V/o° 0.73
80256 11/40 X1°X/2"NPT 40 '/io" V/° 030
80252 11/4"X11/4°X /2°NPT 40 'ho" Vie"V/s° 0.31
80257 V/a"X11/4__x 1/20 NPT 80 6/,u W,1'/,o" 0.43
80254 1'/a"X11/2"X /2°NPT 80 0 ?0.46
80258 2"x1 1/2"X V2°NPT 80 '/2° 5/0 1°/s' 0.56
80253 2°x2°x '/°NPT 180 '/2° 1/30 1°/s° 0.62
LImIted Warranty
Products manufactured by Tyco Fire Product, or. warranted solely to the original Buyer for ten (10) years against defect. In material and workmanship when paid for and Properly Installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Product.. No warranty I. given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Product, or for products and component. which have been subject to misuse Improper Installation. corrosion. or which have not been Installed, maintained, modified or repaired In accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standard, of any other Authorities Having lurisdiction. Material, found by Tyco Fir. Products to be defective shall he either repaired or replaced, at Tyco Fire Products .ol. option. Tyco Fire Products neither assumes, nor authorize, any person to assume for It, any other obligation In connection with the sale of products or parts of product.. Tyco Fire Products shall not be responsible for sprinkler system design error, or inaccurate or Incomplete Information supplied by Buyer or Buyer's representatives.
IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT. TORT. STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY. FOR INCIDENTAL. INDIRECT. SPECIAL OR CONSEQUENTIAL DAMAGESO INCLUDING BUT NOT LIMITED TO LABOR CHARGES REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE.
WngimmM*E.4,R,,C!RiIAINgTA!llilLmlrAYTIEAgiLFlipTrIlME99 FOR A PA W.
tqCo/Rowconv//7,
?yoMOE8MfMO#A xd I.MEbt0 •nxd.bt8 Tot ..
d MØMØ?