Loading...
HomeMy WebLinkAbout1933 DOVE LN; ; AS03022510/8/2020 AS030225 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS030225 Job Address: 1933 DOVE LN Status: ISSUED Permit Type: SPRINK Applied 10/29/2003 Parcel No:. 2150521500 Approved: . 1/14/2004 Lot #: 0 Reference No.: Issued: 1/14/2004 PC #: Inspector: Project Title: LA COSTA GREENS BLDG.6 OH AS PLAN CHECK & INSPECTIONS Applicant: Owner: REAL ESTATE COLLATERAL MANAGEMENT CO C/O LIZ LAYMAN/ MORROW DEV 1903 WRIGHT PL #180 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 472.25 0 472.25 0 at 1/1 LIFEGUARD FIRE PROTECTION,N .C. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, 4P 92056 (760)806-9997 .FAX(760)806-4813 Hydraulic Design Information Sheet çØ Name: La Costa Greens Date: 03/24/04 Location: -1933 Dove Lane" Building: 46 System No. Carport Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP7 Construction: Z Combustible 0 Non-Combustible Ceiling Height 8'-0" Ft. DQ NFPAJ3: El NFPA 231 o Other (Specify) OSpecific Ruling SYSTEM L)IS1UN 0 Light Hazard Ordinary Hazard Group 0 NFPA 231C: Figure: Area reduced ocr NFPA 13 Section 7-2.3.2.4 Made By 1 LI 2 II 3 II Extra Hazard Curve: Date Area of Sprinlder Operation 900 sq ft System Tvoe Density .15 . . Wet 0 Dry 0 Deluge 0 Pre-Action Area Per Sprinkler 125 sq ft . Sprinider or Nozzle Hose Allowance GPM: Inside. 0 Make Tyco Model LFII Hose Allowance GPM: Outside 250 . Sze 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 158.10 PSI Required 65.69 At City Connection "C" Factor Used:. . Overhead 120 Underground 150 Water Flow Test Pump Data Tank or Reservoir 'Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department COMMODITY STORAGE Commodity Class. Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack El Single Row 0 Conventional Pallet 0 Automatic Storage 0 Encapsulated O Double Row []Slave Pallet 0 Solid Shelving 0 Non-Encapsulated O Multiple Row [J Open Flue Spacing In Inches Clearance From Top of Storage to Ceiling Longitudinal ' Transverse , . ' Ft. In Horizontal Barriers Provided I. La Costa Greens Bldg 06 Carport .151900 Sigma Dynamlo. Corporation TTOO Supply I Demand Graph iuiu• • : iiiu uuu• Ii--- iuus ; iiiu• - -€--- - iiii• iui••• iiii•• I iiu•• ii• iuu••____________ iii•• Watar Flow (GPM) System Demand... Sprinkler Deland 61.95 PSI 1 158.10 GPM Additional Flows 250.00 GPM Hose at Source 0.00 GPM Total Demand 62.28 PSI 0 408.10 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00 PSI S 1480.00 GPM )0 SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #6 Carport .15/900 FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 408.1 GPM 0-08-2002 PAGE 1 64.14 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 101 22.13 18.25 5.60 15.62 102 20.24 18.25 5.60 13.06 103 19.31 18.25 5.60 11.89 104 19.05 18.25 5.60 11.57 105 21.22 18.25 5.60 14.36 106 19.39 18.25 5.60 11.99 107 18.50 18.25 5.60 10.92 108 18.25 18.25 5.60 10.62 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 4 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 15 TO 16 158.10 GPM 250.00 GPM 408.10 GPM 62.28 PSI 0.00 PSI 21.63 FPS SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 2 La Costa Greens Building #6 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 104 108 1.080 L 10.00 C=120 PT 10.62 (108) Q 18.25 F=0 F 0.00 PE 0.00 BN T 10.00 0.0953 PF 0.95 23 104DQ 19.05 1.080 L 5.25 C=120 PT 11.57 (104) Q 37.30 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3577 PF 4.78 PT 16.67 ( 23) 103 ------------------ 107 1.080 L 10.00 C=120 PT 10.92 (107) Q 18.50 F=0 F 0.00 PE 0.00 BN T 10.00 0.0978 PF 0.98 22 103DQ 19.31 1.080 L 5.25 C=120 PT 11.90 (103) Q 37.81 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3669 PF 4.90 ------------------ PT 17.12 ( 22) 102106 1.080 L 10.00 C=120 PT 11.99 (106) Q 19.39 F=0 F 0.00 PE 0.00 BN T 10.00 0.1067 PF 1.07 21 102DQ 20.24 1.080 L 5.25 C=120 PT 13.06 (102) Q 39.63 F=T,E F 8.10 PE 0.32 BN T 13.35 0.4002 .PF 5.34 PT 18.72 ( 21) ----------------- 101 105 1.080 L 10.00 C=120 PT 14.36 (105) Q 21.22 F=0 F 0.00 PE 0.00 BN T 10.00 0.1260 PF 1.26 20 101DQ 22.13 1.080 L 5.25 C=120 PT 15.62 (101) Q 43.36 F=T,E F 8.10 PE 0.32 BN T 13.35 0.4725 PF 6.31 PT 22.25 ( 20) 5 4 7.758 L 174.00 C=150 PT 61.88 ( 4) Q 156.14 F=0 F 0.00 PE 0.00 LU T 174.00 0.0002 PF 0.03 6 7.758 L 415.00 C=150 PT 61.91 ( 5) Q 156.14 F=GV,2EE/2BB F 60.40 PE 0.00 LU T 475.40 0.0002 PF 0.10 7 6 7.758 L 623.00 C=150 PT 62.01 ( 6) Q 156.14 F=EE,GV/EB,GV,2BE F 66.44 PE 0.00 LU T 689.44 0.0002 PF 0.14 SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 3 La Costa Greens Building #6 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 8 7 . 7.758 L 220.00 C=150 PT 62.15 ( 7) Q 156.14 F=GV F 6.04 PE 0.00. LU T 226.04 0.0002 PF 0.05 3 8 7.758 L 158.00 C=150 •PT 62.20 ( 8) Q 156.14 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0002 PF 0,05 1 3 7.758 L 1.00 C=150 PT 62.25 ( 3) Q 156.14 F=0 F 0.00 PE 0.00 • LU T 1.00 0.0002 PF 0.00 PT. 62.25 (. 1) 2 ------------------ 4 7.758 L 596.00 C=150 PT 61.88 ( 4) Q 251.96 F=T,GV,4EE/GV.,2EE F 146.52 PE 0.00 • LU T 742.52 0.0005 PF 0.37 1 2 7.758 L 1.00 C=150 PT 62.25 ( 2) Q 251.96 F=0 F 0.00 PE 0.00 LU • T 1.00 0.0005 PF 0.00 PT 62.25 ( 1) 22 ------------------ 23 1.728 L 12.17 C=120 PT 16.67 ( 23) Q 37.30 F=0 F 0.00 PE 0.00 FM T 12.17 0.0363 PF 0.44 21 22DQ 37.81 1.728 L 12.17 C=120 PT 17.11 ( 22) Q 75.12 F=0 F 0.00 PE 0.00 FM T 12.17 0.1324 PF 1.61 20 21DQ 39.63 1.728 • L 12.17 C=120 PT 18.72 ( 21) Q 114.75 F=0 F 0.00 PE .0.00 FM T 12.17 0.2900 PF 3.53 16 20DQ 43.36 1.728 L 41.50 C=120 PT 22.25 ( 20) Q 158.10 F=T F 9.00 PE 0.00 FM T 50.50 0.5246 PF 26.49 15 16 1.728 L 11.50 C=120 PT 48.74 ( 16) Q 158.1.0 F=2E F 7.40 PE 0.00 FM T 18.90 0.5246 PF 9.91 11 15 .2.203 L 7.58 C=120 PT 58.65 ( 15) • Q 158.10 F=CV,E F 15.80 PE 3.28 FR T 23.38 0.1608 PF 3.76 SUBMITTAL SERIAL NO: 2932HY4 03-08-2002-PAGE 4 La Costa Greens Building #6 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 10 11 4.280 L 7.00 C=140 PT 65.69 ( 11) Q 158.10 F=E F 17.92 PE 0.00 UN T 24.92 0.0048 PF 0.12 9 10 4.266 L 118.00 C=150 PT 65.81 ( 10) Q 158.10 F=T/3E F 96.05 PE 0.00 UN T 214.05 0.0043 PF 0.92 ___ 4266 - - -L---7900- C=150 PT -6673-( 9.)- Q 158.10 F=T,cV,DDC/3E F. 99.89 PE -20.37 UN T 178.89 0.0043 PF 0.77 4" Watts 909 RPDA 14.74 PT 47.13 ( 4) 0. 1 ------------------ 7.758 . L 1.00 C=150 PT 62.28 ( 1) Q 408.10 F=0 F 0.00 PE 0.00 UN T 1.00 0.0013 PF 0.00 PT 62.28 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92056 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1933 Dove Lane Building: #6 System No. 2-head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP7 Construction: Z Combustible El Non-Combustible Ceiling Height 8'-0" Ft. SYSTEM DESIGN IZI NFPA 13: El Light Hazard Ordinary Hazard Group 0 1 0 2 D 3 0 Extra Hazard O NFPA 231 0 NFPA 231C: Figure: Curve: O Other (Specify) Specific Ruling Residential Made By Date Area of Sprinkler Operation 2-head . System Type Density .10 Z Wet 0 Dry 0. Deluge 0 Pre-Action Area Per Sprinlder 20' x 20' Sprinider or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinkler Allowance n/a Temperature R1ing 155. - CALCULATION SUMMARY GPM Required 40.21 PSI Requited 55.49 At City Connection "C" Factor Used: Overhead 120 Underground 150 I Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am. Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a . Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 jj Elevation 190' . Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department uivnvivuii x i viutur Commodity Class Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Rack 0 Single Row 0 Conventional Pallet O Double Row 0 Slave Pallet O multiple, Row 0 Open Flue Spacing In Inches Longitudinal - Transverse Horizontal Bathers Provided 0 Automatic Storage. 0 Encapsulated O Solid Shelving 0 Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. La Costa Greens Bldg 06 2-head cab Sigma Dyn•mlua Corporation 7100 8uDDlv I Demand Grah I II.... Margin_________ Pressure 15.50 PSI Flo 2199.63 GP;r= : i.... • 'iuiu ___________ ___________ ;• I iu•u ------ - -€--- - iui• iuuu• 1111• Water Flow (GPM) System Demand.. Sprinkler Demand Additional Flows Hose at Source Total Demand 49.29 PSI 49.29 PSI 40.21 GPM 0.00 GPM 0.00 GPM 0 40.21 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI Elevation 0.00-PSI 1 1480.00 GPM SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 1 La Costa Greens Building #6 second floor 2-head calculation 20' x 20' spacing FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 40.2 GPM 64.79 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 162 20.21 20.00 4.90 17.02 163 20.00 20.00 .4.90 16.66 TOTAL WATER REQUIRED FOR SYSTEM 40.21 GPM TOTAL WATER REQUIREMENT 40.21 GPM PRESSURE REQUIRED AT 0 49.29 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.00 PSI MAXIMUM VELOCITY FROM 150 TO 151 13.55 FPS SUBMITTAL SERIAL NO:2932HY4 03-08-2002. PAGE 2 La Costa Greens Building #6 second floor 2-head calculation 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 161 163 1.101 L 13.00 C=150 PT 16.66'(163) Q 20.00 F=DPV,E F 6.00 PE 0.00 AO T 19.00 0.0680 PF 1.29 PT 17.95 161 162 ------------------ 1.101 L 7.50 C=150 PT . 17.02 Q 20.21 F=DPV,E F 6.00 PE 0.00 AO T 13.50 0.0694 PF 0.94 160 161DQ 20.00 1.101 L 2.50 C=150 PT 17.96 (161) Q 40.21 F=T/E F 10.00 PE. 0.22 BN1 T 12.50 0.2477 PF 3.10 152 160 1.101 L 33.00 C=150 PT 21.28 (160) Q 40.21 F=E,DPV,4E/2DPV,E F 33.00 PE 0.00 BN1 T 66.00 0.2477 PF 16.35 PT 37.63 (152) 150 151 ------------------- -1.101 L 1.75 C=150 PT 44.67 (151) Q 40.21 F=T/E F 10.00 PE 0.32 BN T 11.75 0.2477 PF 2.91 PT 47.90 (150) 5 4 - - 7.758 L 174.00 C=150 PT 49.29 ( 4) Q 15.23 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 6 5 7.758 L 415.00 C=150 PT 49.29 ( 5) Q 15.23 F=GV,2EE/2EE .F 60.40 . PE 0.00 LU T 475.40 0.0000 PF 0.00 7 6 7.758 L 623.00 C=150 PT 49.29 C 6) Q 15.23 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 8 7 7.758 L 220.00 C=150 PT 49.29 ( 7) Q .15.23 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 C=150 PT 49.29 ( 8) Q 15.23 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0000 PF 0.00 1 3 7.758 . L 1.00 C=150 PT 49.29 ( 3) Q 15.23 F=0 F 0.00 PE 0.00 LU T 1.00 0.000.0 PF 0.00 PT 49.29 ( 1) SUBMITTAL SERIAL NO:2932HY4 . 03-08-2002 PAGE 3 La Costa Greens Building #6 second floor 2-head calculation 20' x 20' spacing Location Flow Pipe. Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI ------------------- 2 4 7.758 L 596.00 C=150 PT 49.29 ( 4) Q 24.98 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 49.29 ( 2) Q 24.98 F=0 F 0.00 .PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 49.29 ( 1) 151 152 -- - . 1.101 . L 10.00 C=150 PT 37.61 (152) Q 40.21 F=DPV F 1.00 PE .433 FR]. T 11.00 0.2477 PF 2.72 ------------------ PT 44.66 (151) 16 150 1.728 L 68.00 C=120 PT 47.91 (150) Q 40.21 . F=T F 9.00 PE 0.00 FM T 77.00 0.0417 PF 3.21 15 16 1.728 L 11.50 C=120 PT 51.12 ( 16) Q 40.21 F=2E F 7.40 . PE 0.00 FM T 18.90 0.0417 PF 0.79 11 15 . 2.203 . L 7.58 C=120 PT 51.91 ( 15) Q 40.21 . F=CV,E F 15.80 PE 3.28 FR T 23.38 0.0128 PF 0.30 10 11 4.280 L 7.00 C=140 PT 55.49 ( 11) Q 40.21 F=E F 17.92 PE 0.00 UN T 24..92 0.0004 PF 0.01 9 10 4.266 L 118.00 C=150 PT 55.50 ( 10) Q 40.21 F=T/3E F 96.05 PE 0.00 UN T 214.05 0.0003 PF 0.06 4 9 4.266 L 79.00 C=150 PT 55..56 ( 9) Q 40.21 F=T,GV,DDC/3E F 9.9.89 PE -20.37 UN T 178.89 0.0003 PF. 0.05 4" Watts 909 RPDA 14.02 PT 35.24 ( 4) 0 1 .7.758 L 1.00 C=150 PT 49.29 ( 1) .. Q 40.21 F=0 F 0.00 PE 0.00 UN . T 1.00 0.0000 PF 0.00 PT 49.29 ( 0) LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 920:56 (760) 806-9997 • FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1933 Dove Lane Building: #6 System No. 1-head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP7 Construction: . Combustible El Non-Combustible Ceiling Height 8'-0" Ft. IJ NFPA 13: NFPA 231 Other (Specify) ZSpecific Ruling SYSTEM DESIGN 0 Light Hazard Ordinary Hazard Group 0 NFPA 231C: Figure: Residential . . Made By 1 LI 2 U 3 U Extra Hazard Curve: Date Area of Sprinlder Operation 1-head . System Type Density .10 . Wet 0 Dry 0 Deluge 0 Pre-Action Area Per Sprinlder 18'x 18' . . SprinlderorNozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinider Allowance n/a. Temperature Rating 155 LOP i S]L1SJM!' GPM Required 1768 PSI Required 28.22 At City Connection "C" Factor Used: . Overhead 120 Underground 150 WAT1R SI TPPI V Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department Commodity Class Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack Rack O Single Row 0 Conventional Pallet El Double Row 0 Slave Pallet O Multiple Row 0 Open Flue Spacing In Inches Longltodinal Transverse Horizontal Bathers Provided El Automatic Storage 0 Encapsulated O Solid Shelving . 0 Non-Encapsulated Clearance From TOD of Storage to Ceiling Ft. In. La Costa Greens Bldg 06 1-head cab Sigma Dynamic. Corporation 7700 Supply I Demand Graph —. ____________________________ iLIr)L.Ll,:i PSI i. w 3970. 5L!tK- I_..____ 'iuiu• I. .1 iuiu• • uuiu• 1uu• II.... - - - -- 'iii uiva• 'ii•u• i• ; 'I'I'~Iim I' [K' 14J Water Flaw (CPU) System Demand.. Sprinkler Demand 19.66 PSI 117.69 GPM Additional Flows 0.00 GPM Hose at Source 0.00 GPM Total Demand 19.66 PSI S 17.68 GPM Water Supply.. Static 64.80 PSI Residual 57.60 PSI 1 1480.00 GPM Elevation 0.00 PSI SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 1 La Costa Greens Building #6 second floor 1-head calculation FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 17.7 GPM 64.80 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 164 17.68 17.00 4.90 13.02 TOTAL WATER REQUIRED FOR SYSTEM TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 150 TO 151 17.68 GPM 17.68 GPM 19.66 PSI 0.00 PSI 5.96 FPS 'I SUBMITTAL SERIAL NO:2932HY4 03-08-2002 PAGE 2 La Costa Greens Building #6 second floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 160 164 1.101 L 13.00 C=150 PT 13.02 (164) Q 17.68 F=DPV,2E F 11.00 PE 0.22 AO T 24.00 0.0542 PF 1.30 152 160 1.101 L 33.00 C=150 PT 14.54 (160) Q 17.68 F=E,DPV,4E/2DPV,E F 33.00 PE 0.00 BN1 T. 66.00 0.0542 PF 3.58 PT 18.12 (152) 150 151 ------------------ 1.101 L 1.75 C=150 PT 23.04 (151) Q 17.68 F=T/E F 10.00 PE 0.32 BN T 11.75 0.0542 PF 0.64 PT 24.00 (150) 5 4 ------------------ 7.758 L 174.00 C=150 PT 19.66 ( 4) Q 6.06 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 6 5 7.758 L 415.00 C150 PT 19.66 ( 5) Q 6.06 F=GV,2EE/2EE F 60.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 7 6 7.758 L 623.00 C=150 PT 19.66 ( 6) Q 6.06 F=EE,GV/EE,GV2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 8 7 7.758 L 220.00 C=150 PT 19.66 ( 7) Q 6.06 FGV F 6.04 PE ' 0.00 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 ' C=150 PT 19.66 ( 8) Q 6.06 F=GV,EE/GV,T F 78.57 PE 0.00 LU T 236.57 0.0000 PF 0.00 1 3 7.758 L 1.00 C=150 PT 19.66 ( 3) 6.06 F=0 F 0.00 PE 0.00 LU T 1.00 '0.0000 PF 0.00 ------------------ PT , 19.66 ( 1) 2 4 7.758 L 596.00 C=150 PT 19.66 ( 4) Q 11.62 .F=T,GV,4EE/Gv,2BE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.00 C=150 PT 19.66 ( 2) Q 11.62 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 19.66 ( 1) SUBMITTAL SERIAL NO:2932HY4 03-08-2002. PAGE 3 La Costa Greens Building #6 second floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & . Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI -------------- 151 152 .. 1.101 L 10.00 C=150 PT 18.11 (152) Q 17.68 F=DPV F 1.00 PE 4.33 FRi T 11.00 0.0542 PF 0.60 PT 23.04 (151) 16 150 ------------------ 1.728 L 68.00 C=120 PT 24.00 (150) Q 17.68 F=T . F 9.00 PE 0.00 FM T 77.00 0.0091 PF 0.70 15 16 1.728 L 11.50 C=120 PT 24.70 ( 16) Q 17.68 . F=2E F 7.40 PE 0.00 FM T 18.90 0.0091 PF 0.17 11 15 2.203 L 7.58 C=120 PT 2.4.87 ( 15) Q 17.68 F=CV,E F 15.80 PE 3.28 FR T 23.38 0.0028 PF 0.07 10 11 4.280 L 7.00 C=140 PT 28.22 ( 11) Q 17.68 F=E F 17.92 PE 0.00 UN . T 24.92 0.0001 PF 0.00 9 10 4.266 L 118.00 C=150 PT 28.22 ( 10) o 17.68 F=T/3E F 96.05 PE 0.00 UN T 214.05 0.0001 PF 0.02 4 9 4.266 L 79.00 C=150 PT 28.24 ( 9) Q 17.68 F=T,GV,DDC/3E F 99.89 PE -20.37 UN T 178.89 0.0001 PF 0.02 4" Watts 909 RPDA 11.77 PT . 7.89 ( 4) 0 1 . 7.758 L 1.00 C=150 PT 19.66 ( 1) Q 17.68 F=0 F 0.00 PE 0.00 UN . T 1.00 0.0000 PF 0.00 PT 19.66 ( 0) B LIFEGUARD FIRE PROTECTION, INC. 20505 TEMPLE HEIGHTS DRIVE, STE. F OCEANSIDE,_CA9205S 700-80-9997 • 7080g-4813 FIAX Protection Design & Consulting - Db ith.. Comment. Dae 'ga . %~ A6o3o7.!~5~ /1 tCop,. M,ATERAL DATA SUBMITTAL La Cosfo Greens Building i*3 1933 cove Lane Carlsbad, CA. DOUBLE CHECK DETECTOR ASSEMBLY BACKFL.OW PREVENTION Physical Properties U.S. Patent No. 4.M.635 • U.S. Patent No. 5.107888 U.S. Patent No. 5.385,166 • U.S. Patent No. 5.22M41 Size of Mainline 2-1/2", 3 4" 80, 8", & 10" U.S. Patent No. 5.392.803 • U.S. Patent No, 5.5W,176 Max. Working Pressure 175 PSI (1200 KPa) Hydrostatic Test Press. 350 PSI (2400 KPa) Temperature Range 320 F to 1400 F (00 C to 600 C) End Connections Flanged ANSI B16.1 Class 125 0 Materials Main Valve Body Coating Shut Off Valves Trim Elastomer Discs Spring Installation Views - 18" min Ductile iron Grade 65-45-12 Fusion epoxy coated internal and external AWWA C550-90 OS & Y resilient wedge gate valves AWWA C509 Bronze EPDM Stainless steel MODEL 876V DOUBLE CHECK DETECTOR (Shown In vertical posItion) MODEL 8760876V DOUBLE CHECK DETECTOR (Shown In standard orientation) Suppod iilied by customer) sJv. weIght 01*/. FLOW Standard orientation (Model 876'I876V) * Note-Model 876 does not include grooved end coupling. Recommended minimum clearances from permanent structures for ease of testing and maintenance. Vertical orientation (Model 876V) , A ~~ ,q !I 876/876V Materials of Construction ITEM DESCRIPTION MATERIALS ITEM DESCRIPTION MATERIALS ITEM DESCRIPTION MATERIALS I Body A536 GR 6545-12 8 Lower Spring RetaIner 8584 Alloy C83600 26 Gasket EPDM ASTM 02000 2 Cover A536 GR 6545-12 9 Spring Stem 30488 35 0-ring EPDM ASTM 01999 2.1 0-ring EPDM ASTM 02000 9.1 mastic Stop Jam Nut 18-8 $$ 35.1 Back Up Ring Metal Resin 2.2 Cap Screw Plated Steel 10 Spring A313 Type 631 SS 36 Cover 8584 Alloy C83600 2.3 Hex Nut Plated Steel 10.2 Spring Shim Acetal Resin 40 Ball Val* 8584 Alloy C83600 2.5 Cover (w/o holes) A536 GR 65-45-12 10.3 Spring Shim Acetal Resin 41 Nipple Brass 3 Seat Ring 8524 Alloy C83600 ii Spring Guide B130 Alloy C22000 42 Gate Valve (OS&Y) AWWA C509 3.1 Gasket EPDM ASTM D2000 12 Upper Spring Retainer 8584 Alloy C83600 43 Bulkhead Filling 8584 Alloy C83600 4 Arm B584 Alloy C83600 12.1 Bushing Spring Stem Acetal Resin 43.1 Bulkhead Filling 0584 Alloy C83600 4.1 4.2 Bushing-Swing Pin Metal Resin 13 Pivot Bearing - 8585 Alloy C83600 44 Bulkhead rifling B584 Alloy C83600 Swing Pin 30488 14 Flange Gasket RubberlFabrlc 45 Gasket EPDM ASTM 02000 5 5.1 Retaining Clip 302 SS 15 Bearing Socket Metal Resin 45.1 Gasket EPDM ASTM 02001 6 Retaining Clip Check Disk (2-112 - 8) 302 SS EPDM Coated GR. 45 16 Hex Jam Nut 18-8 SS 46 Washer 836 Alloy 260 Ductile Iron Capsaaw, (l(r Only) 18-8 SS 46.1 Washer 836 Alloy 280 WI type 304 SS 17 18 Washer 302 SS 47 Nut 8584 Alloy C83601 Seat Disc (10Only) Silicone ASTM 02000 18.1 Flange Nut Plated Steel 47.1 Nut 8584 Alloy C83602 6. Disc Holder (10 Only) ASTM A743 304 SS Flange Nut Plated Steel 60 Identification Plate B36 Alloy C26000 6.2 Disc Retainer (10k Only) ASTM A743 304 SS 19 24 Cover Bolt A36 511. Epoxy Coated 61 Identification Plate B36 Alloy C26000 6.3 Plated Steel 62 Drive Screw Stainless Steel 7 Capscrew(l(Only) Load Pin 118-8 SS 30458 24.1 25 Washer Bolt Plated Steel Plated Steel 10 Clamp 876VOnly AWWAC6O6 08 &Y Side View arooved end CE Model 876V Model 876V Standard Orientation Vertl Oritaticn Note: The Model 876V is shipped in the standard (N-Shape) orientation as shown Dimensions Approximate El Net oS&Y Osay Size A B C OPEN F G. H J K M (Lbs.) 2112" 12' 2914 24'1 1634 1661. 61k 11 112 3'I2 1361. 271!. 230 65 317.50 654.05 615.95 415.93 42228 158.75 292.10 88.90 348.08 692.15 104.33 3" 1211 2534 24314 2214 1611h 61!4 111h 3314 141I6 2811, 300 80 317.50 654.05 628.65 565.15 422.28 158.75 292.10 95.25 35818 717.55 136.08 4 14 27!6 2914 231/4 1l'14 7 13 4' 15'12 31 330 100 355.80 708.03 679.45 590.55 450.85 177.80 330.20 114.30 393.70 787.40 149.69 on 16 32'1 3211 3011e 214!? 8 13 5112 1851e 37114 520 150 406.40 819.15 819.15 765.18 547.9 203.20 330.20 139.70 473.08 946.15 235.87 8" 18112 37112 363/8 37314 24116 911. 1411 6 3 14 20!4 4111a 860 200 469.90 952.50 923.93 958.85 631.80 234.95 368.30 171.45 527.05 1054.10 390.09 10" 21 421!2 4031 48 27'!. 10 15 8 24 48 1480 250 533.40 1079.50 1035.05 1219.20 698.50 254.00 381.00 203.20 609.60 1219.20 682.24 Weights do not include risers or optional valve setter. Note: Dimensions shown are nominal. Allowances must be made for normal manufacturing tolerances. Refer to Specification Sheet SS VS for details on valve setter. Application Non-Health Hazard Fire Sprinkler Systems Flow Orientation Standard orientation Is inlet flow vertical up, outlet flow vertical down. Vertical orientation is inlet and outlet flow vertical up. Options 0 Valve Setter with MJ x FL, MJ x MJ or FLxFL ends Agency Compliance Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California. ASSE (Ste. 1048) ANSI/AWWA (C510-89) CAN/CSA (B64.5) FM* UL* cUL Less gate not FM approved. Less gate not UL Hated unless Installed with UL lIsted gated valves. Model 8761876V Flow Curves I- ,,- - — -- --- - - - - I I It I II I II I II II .11 II III It II - _ I II III II III 'It III 10" 18 16 .14 12 10 2 BI 16 14 ,12 10 38 2 B 0 100 200 30) 40) GPM A-Vertical orientation (model 876V) B-Standard orientation (model 876) 500 600 70) 0 1000 2000 3000 4000 5000 GPM The W and 10" flow curves in the standard orientation include the FEBCO valve setter model 611. FEBCO Bacictiow Prevention P.O. Box 8070• Fresno, CA 93747-8070 559 252-0791 Far 559453-9030- www.cmb-Ind.com NOW OliOl vIW901 cus kIthEUee. Inc. 7-]CM InmstrIs, Inc. A ON-6 a COWAN/ ISO 9001 Certified Scheduleml0q/Schedulem406 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (l"- 8") pipe and Sch-40 (1"- 2'4") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. [iISpecifications NPS Nominal I.D. WI. Wt. (1120 Filled) Pcs/ WI/Lift (21) WI/Lift (24) WI/Un (25) In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.049 1.680 2.05 70 21470 2.822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1W 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1'/2 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2W 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 UTT1i'iii. NPS Nominal I.D. M. WI. (1120 Filled) PCs/ WI/LIft (21) WI/LIft (24) WI/LIft (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1W 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1W 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 20 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5° 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6' 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 80 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 11309 Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tqcu/Fiow Control allied TUBE & CONDUIT @ <S> 0 1 Listed Approved Listed 16100 S. Lathrop Harvey, IL 60426 Customer Service: 11350 Norcom Rd.. Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. 'Phoenix, AZ 85009 Fax 708-339-1806 S5-3 $1 per Flog/DynawFlowe Aigh Strength Steel Pipe— The original high-strength IightwaIl sprinkler pipe with hydraulics superior to Schedule-10, Super Flo/Dyna-Flow pipe is the "original1' high-strength lightwall sprinkler pipe. Super Flo/Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Super Flo/Dyna-Flow is a valuable addition to any fire protection system. 4 Superior Hydraulics _ With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, SuperFlo/ Dyna-Flow pipe hydraulics are exceptional. er I.D.s enable Super Flo/Dyna-Flow, .uid related components, to be down- sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to "Super Flo/Dyna-Flow Hydraulic Data Tables." Coatings & Fabrication Super Flo/Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is painrable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No .'-"cial process or equipment are needed fabrication and installation. -n allied TUBE & CONDUIT Ill, Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Lift Wt/ Lift Wt/Llft NPS 1. D. H20 Filled Lift 21' 24' 25' X 1" 1.191 0.830 1.31 91 1586 1.81.2 1888 *25 30.3 1.2 1.95 91 719 822 856 x 1 1/4" 1.536 1.059 1,87 61 1356 1550 1615 *32 39.0 1.6 2.78 61 615 703 733 xl 1/2" 1.728 1.667 2.71 61 2135 2440 2542 *40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1634 1868 1946 *50 56.0 - 3.1 5.64 37 741 847 883 x21/2" 2.703 264 5.10 30 1615 1846 1923 *65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1351 1544 1608 *80 84.2 5.0 10.69 1.9 613 700 729 x 4" 4.310 4.473 10.86 19 1784 2039 2124 *90 109.5 6.7 16.16 19 809 925 963 x6" 6.403 7.714 21.70 10 1620 1.851. 1928 *150 162.6 11.5 32.29 10 735 840 875 Specifications & Approvals Super Flo/Dyna-Flow pipe is manufactured to meet ASTM A- 795 pe E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/SuperFlo are UL Listed, FM Approved and ULC Listed. (@ 0 t0c Listed Approved Listed Super Flo/Dyna-Flow is UL/ULC Listed for use with roil grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information, Super Flo/Dyna-Flow is now available "hot-dip"galvanjzed and has been specifically approved by FM for dry systems uses, Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. - Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. 1.6100 S. Lathrop 11350 Norcom Rd. 2525 N. 271h Ave. Customer Service: Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 1•800-797-6210 Fax 70,9-339-1806 ubmttaI Data Sheet Super 40®/Dyna-Thread" Slamp Here Full Line Sch-40 Replacement Super -lWDvna.Thread sprinkler pipe represents an engineering advancement for the. sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantes. Comparison to Schedule 40 Super 40/Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe. down sizing often occurs. Super 40/Dyna-Thread is Fully listed and approved UL. ULC, and FM for lire sprinkler applications. The life expectancy of Super 40/Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL (see CRR), The consistent qualify of steel u-ed to make Super 40/Dna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Super 40/Dyna-Thread is protected by a clean, durable mill coating for extended Ii life and easy paint application. With its increased strength and lighter weight. Super40/ 0.. tin-Thread reduces installation ln igue and is ideal for retro-fit applications. Corrosion lciiance Ratio ICRRt is a UL. (Underwriters Laboratory) term for the estimated life expecuiney ot a pipe joint. This is based on the calculated wall thickness at the base of the First exposed thread, n.timed to be the weakest point of the pipe length. Super 40/Dyna-Thread and Sch-40 have the .ttne calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.K.T. Pipe More wall thickness at the thread (CRR1.00) gives Super 40/Dma-Thread better life expectancy than hightwall threadable pipe joints. Unlike lighiwall threaduble pipe. Super 40/Dyna-Thread has no thread gauge warning. Super 40/ Dyna-Thread is approved for standard hanger spacing( 15 ft. O.C.. can be used as earthquake sway lracing. and is safe to use as drops. Super 401 Dyna-Thread is safer to weld on than many zinc-coated light wall threadable pipe products. Super 40/Dyna-Thread is more widely accepted than lighiwall threadable where Sch-40 is specified. Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Lilt Wt/Litt Wt/Lift NPS 1. D. H20 Filled Lift 21 24' 25' X 1 1.080 1.330 1.75 70 1955 2234 2327 *25 27.4 2.0 2.60 70 887 - 1013 1056 1 1/4 1.408 1.870 2.54 51 2002 2288 2384 *32 35.8 2.8 3.78 51 908 1038 1081 1 1/2 1.639 2.290 3.22 44 2115 2418 2519 *40 416 3.4 4.79 44 959 1097 1143 x2 2.104 3.050 4.57 30 1921 2196 2287 *50 53.4 4.5 6.80 30 871 996 1037 American Tube and Pipe was acquired by Allied Thbe and Conduit on February 1, 1997. The engineered lighiwall and standard wall family or products although they have different names are the same in all respects with regard to strength weight, bundle count listings and approvals. For example, Dyna.Flow and Super Plo are the same product as are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is manufactured ivith Black lacquer catlng. Project: Sprinkler Contractor: Date: Engineer: Specification Reterence: System Type: Locations: Comments: Spèifications & Approvals Siiper4O/Dyna-Thread pipe is mnnttliucrttred to meet: ASTM A 135. Grade A and is in compliance u ith NFPA- 13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dma-Thread is UL and ULC Listed for wet, dry atid pre-action sprinkler systems and FM Approved fur use in wet systems. Super 40/Dyna-Thread can be hot-dip' galvanized to meet FM requirement ku dry NY.Uems. Super 40/Elyria-Thread is approved fur all threaded couplings and celded outlets and is suttable for all roll-grooved, and plain-end fittings. (See listing information). (9-L 0 @ Listed Approved LtIed Flow Data Friction Resistance The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed cnn be estimated from the data given, for example, a 221/20 elbow is appluidmately one-halt the resistance of a 450 elbow. Values of rind-sizes can be interpolated. IFIS CARBON' ISTE Grooved IPS Fittings Victaulic fittings are designed specifically for use in grooved piping systems. Victaulic offers a broad line of fittings in sizes through 24' (600 mm) in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are 'supplied with grooves or shoulders to permit last installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to page 55 for fittings available for plain end applications). Fittings are provided in various materials including malleable iron, ductile iron, steel or segmentally welded steel depending on styles and size. Fittings pre painted orange enamel with galvanized optionally available, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or with shoulders conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange adapters, check disc clearance dimensions with I.D. dimension of fitting. Request 07.01. Alternate Materials Stainless Steel - Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 optionally available) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Request 17.04 for details. Aluminum - Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 - 8' (25 - 200 mm). Request 21.03 or contact Victaulic for details, Alternate Styles EndSeal "ES" Fittings - EndSeal fittings are available in 2 - 12' (50 300 mm) for use with "ES" grooved pipe and HP-70ES EndSeal or FiroRT1 couplings. "ES" fittings are painted green for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EudSeal fittings" when ordering. Request 07.04 for information on EndSeal fittings, Fittings Machined for Rubber or Urethane Lining (MRL) -' For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Request 25.03 or contact Victaulic for specific details: Pipe Pipe Inches/mm Equivalent Feel/meters ofStraight Pipe Inches/mm Equivalent Feel/meters of Straight Pipe - - 900 Elbows 450 Elbows Tees 900 Elbows . 451 Elbows Tees No. 100 No. 110 No. No. 110 No.10 1½0 No. 1 1 1½D No.10 1½0 No. 11 1½0 Nom. Actual SId, Long Std. Long Nom. Actual SId. Long Sid. Long Size Size Radius Radius Radius Radius Branch Run Size Size Radius Radius Radius Radius Branch Run 1 1.315 1.7 - 0.8 - 4.2 1.7 6 6.625 10.0 7.5 5.0 3.0 20 10.0 25 311 (L5 0.2 . 13 0.5 150 1683 30 2.3 1.5 0.9 76 10 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 6.500 9.6 -. 5.0 - 25.0 10.0 50 60.3 1.1 08 05 03 26 ii 64 1851 2.9 - 15 7.6 30 3.000 4.3 -. 2.1 -. 10.8 4.3 8 8.625 13.0 9.8 6.5 4.0 33.0 iao 76.1 1.3 ... 07 .. 33 1.3 200 2191 4.0 3.0 2.0 1.2 101 40 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 80 88.9 15 12 08 0.5 40 1.5 250 273.0 52 3.7 2.5 1.5 1 12.5 5.2 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 12 12.750 20.0 14.5 10.0 6.0 50.0 200 100 1143 21 15 10 06 49 2.1 300 3239 6.1 4.4 30 1.8 15.2 61 04t 4.250 6.4 3.2 15.3 6.4 14 14.000 41 23.0 If 18.0 60.0 17.0 ioao 1 1.8 09 . 47 20 350 3556 4 7.0 it 5.5 1113 5.2 5 5.563 8.5 - 4.2 - 21.0 8.5 16 16.000 41 26.0 Il 20.0 70.0 20.0 125141.32.6 1.3 -. 6.4 26 111)0 40134 it 79 II ill 213 (31 5.250 8.1 - 4.1 - 20.0 8.1 18 18.000 41 29.0 41 23,0 80.0 2,0 25 1.6 6.7.2.5 450 457.0 41 5.6 if O 24470 5.500 8.5 - 4.2 - 21.0 8.5 20 20.000 If 33,0 II 26.0 90.0 25.0 2.6 - 1.3 6.4 2.8 1 500 508.0 5 10.1 Ii 7.9 27.4 7.6 6.250 9.6 - 5.0 -. 25.0 10.0 24 24.000 If 40.0 41 30.0 30.5 34.0 159.0 2.9 .- 15 . 76 30 600 '100 U 12.2 U 91 93 10.4 It '...UIIidLI Viciauliu IOF details. O.D. Dimension. 14 The unique angle-pad design of ZeroFlex® Style 07 adjusts to standard pipe and roll or cut groove tolerances, positively clamping the pipe to resist flexural and torsional loads. Wider key section fills more of the groove area. Request 06.02. Style 77 Standard Flexible Coupling Style 77 couplings are designed with cross-ribbed construction to provide a strong component for pressure piping systems. Sizes 3/4 -12(20-300 mm) are two-piece housings. Sizes 14 - 22 (350 - 550 mm) are cast in four identical segments, With larger sizes cast in six segmelflS. Request 06.04. I P :AM OU 114 GROOVED' COUPUNGS' ....... ...... Style 07 ZeroFlex® Rigid Coupling 0 x 2- 12" Sizes c J O 14-16 Sizes 18- 24" Sizes ICV' WO :V.- 12° Sizes 14-22 Sizes 1zr. iZr. 10 24" Size Nom, Size Max. Work Press. Dimensions - Inches/mm WgIEach X Y Z Inches/mm PSI'/kPa LbsAg 750 2.45 4.13 1.88 1.6 132 105 -Ill it 11/4 750 2.60 4.00 1.88 1.6 :3.' :,I'5 06 10? -.43 07 11/2 750 2.94 4.81 1.88 1.6 :i 22 119 07 2 750 3.19 - 5.44 1.88 2.3 10 2½ 750 3.68 6.13 1.88 2.8 750 4.25 5.75 1.86 3.6 31: )17 'mill 146 113 3 750 4.56 6.81 1.88 3.1 130 17!1 lid 173 4111 1.1 4 750 5.81 8.25 2.06 4.8 103) :,1 1.111 2113 52 22 750 5.56 7.44 2.06 5.2 41/4 1 :',i7, 1.11 11,9 1;:' 5 750 7.06 9.75 2.06 7.1 '15 170 248 5.1 .3 700 6.36 9.18 2.06 7.4 :11121. 74 33 700 6.94 9.42 2.06 7.6 5½t i6 .'33 .4-I 6 700 8.00 10.75 2.06 8.7 I. '11325 203 : 52 3 700 7.85 10.18 2.06 9.2 6¼ .I 331:•'lm 99 259 5? -i 700 6.00 10.75 2.06 7.2 4625 "03 .52 3 2 600 10.25 13.50 2.50 14.9 71(1) .1 130 No 3.13 94 (41; 10§ 500 12.88 16.75 2.56 25.0 J 'U 3453) .37 32,3 61, 1 '.3 12§ 400 14.88 18.50 2.56 28.2 :400 .'7,t) .4713 I'ii 95 '23' 14 300 16.19 19.75 2.94 32.8 411 '('2 75 1'10 16 300 18.38 21.75 2.94 411.2 .1(13) 1((155 467 ,:33 71, ii3 18 300 20.69 23.88 3.06 54.2 iso :'o, 571, 9044 75 24 0 20 300 23.00 27.38 3.06 67.2 7,361, 34 319:, 78 .13) 5 24 250 27.13 31.50 3.13 76.2 31,13) i7':, '1339 3043 70 3.10 O.D. Dimension. Refer to notes on page 7. § Available to J.I.S. dimension '? Woi 'ess. Dimensions - Inches/mm Wgi. Each X V Z Inches/min PSI/lPa Lbs./kg 3/4 1,000 2.13 3.63 1.75 - 1.1 03)3)9 ;14 04' .1_I it I' 1 1,000 2.38 3.88 1.75 - 1.3 'A 6900 140 0143 .1.1 01; 1'/, 1,000 2.63 4.63 1.75 2.0 13900 i' 1144 4.1 9)) 11/2 1.000 3.00 5.00 1.75 2.1 £9 049933 16 i? 1.1 It) 2 1,000 3.63 5.63 1.75 2.6 ml 9)1330 9? 143 II 2½ 1,000 4.25 6.25 1.75 3.1 '35 3000 Wlt iso .1.1 1.1 31: 1,000 4.31 6.31 1.75 3.6 119 1339 1.1 113 3 1,000 5.00 7.00 1.75 3.5 130 11900 12.' 1 .i .34 1,1 3½ 1,000 5.63 8.00 1.75 5.6 90 0900 143 21).; 1.1 ' 1' it 1.000 6.38 8.50 2.00 - 6.6 3111)33 111' .110 1,1 iii 4/1: 1,000 5.88 8.06 2.06 - 7.0 i'lL) 5 1,000 7.63 10.25 2.00 - 10.6 (19130 19.3 .'00 SI .l t) 1: 1.000 7.34 9.20 2.06 10.0 (3900 190 234 112 .1 5%.f 1,000 7.60 9.44 2.06 11.0 61)X01 1043 'Ii) :,? 1.1) 6 1,000 9.00 11.50 2.00 11.8 439(13) 229 ji.' 51 :' -I 6/4 1: 1000 8.50 10.38 2.06 13.2 330430 21(1 '6.1 :':' 130 6 * 1,000 9.19 11.50 2.06 - 13.2 ooc .'a :'2 ill' 8 § 800 11.38 14.50 2.38 - 20.1 203) :,(100 9th) .4043 90 111 10 § 800 13.50 16.75 2.50 - 28.3 '500 :143 .l75 0.1 12 § 800 16.50 19.00 2.50 34.2 3110 SSJO .39.1 193 9.1 15:. 14 300 16.63 20.00 2.88 - 35.6 3065 413 s3) ill I 15 300 17.88 21.25 2.88 - 48.8 16 300 19.00 22.36 2.68 - 51.1 :.13.11 .1133 11613 :3 ;' 18 300 21.25 24.38 3.13 - 64.4 -'lit) 2961' tlO 3310 70 20 J 300 23.50 27.50 3.13 - 91.2 21131:, sO' 1)03) ..9 4 1 22 300 25.83 30.00 3.13 - 92.0 510 2'S ilDi '02 79 41 7 24 250 27.63 31.38 3.13 - 94.0 1)00 172:4 'Oi' 9' 1: O.D. Dimension. . Refer 10 notes on page 7. § Available to J.I.S. dimension. Size Range - 1/4 thru 1-1/2 inch rod in 10'-0" lengths. Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain, Electro-Galvanized, and Stainless Steel. Order By - Figure number, rod diameter, and finish. MAX. REC. LOAD LBS, APPROX. ROD FOR SERVICE TEMPS WEIGHT SIZE 650'F 750'F PER 100 FT. 1/4 240 215 12 1/2 1130 1010 .53 3/4 2710 2420 123 J79 ki 4960 4420 222 1-1/2 11630 10370 510 I PAM To C.- . U INCORPORATED CORONA. CA • (909) 737-5599 53 FIG. 99 ALL THREAD ROD CUT TO LENGTH Size Range 3/8 thru 7/8 inch rod in 1 inch increments. Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain, Electro-Galvanized, and Stainless Steel. Order By - Figure number, rod diameter, rod length, and finish. MAX. REC. LOAD LBS. ROD FOR SERVICE TEMPS. SIZE 650F 750F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 FIG. 100 ALL THREAD ROD FULL. LENGTHS TOL o INCOPO1ATD CORONA. CA • (909) 737.5599 15 FIG. 2 ADJUSTABLE RING HANGER FIG, 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range - 1/2 thru 6 inch pipe. Material - Carbon Steel, Mu. Galvanized to G-90 specification. Function - For general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed. Approvals - Underwriters' Laboratories listed and Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature .650'F Finish - Mil. Galvanized and Stainless Steel. Order By - Figure number and pipe size. PIPE ROD STOCK MAX. REC. APPROX. WEIGHT PER 100 FIG. 2 SIZE SIZE A B C SIZE LOAD LBS. FLG.2 NFPA 1/2 3/8 3.1/8 2-5/8 1.3/8 16gax1 400 17 17 ..i;:.•. ......... •.. . .... - /4 1 3/8 3-3/8 2-5/8 1-1/8 169ax1 400 18 18 j 1-1/2 3/8 3-7/8 2.7/8 1 169ax1 400 21 21 t. 4 a6a1 400 1/2 2-1/2 * 5-3/4 4-1/4 1.5/8 149ax1-3/16 600 41 40 3 /2' 4 1/8 jt-14 ,. J4j1 23,'6 600 3-1/2 112* 7.3/8 5-1/4 2.1/8 14a>1-3/16 600 52 50 ';•.1 ., .. .... ....... u .. . 'Lt 1/4 . . .. . . ....... ... . .,; . 1000 5 5/8 9 6-1/8 2.1/4 l2gaxl.1/4 1250 L! - 97 95 3/8 nut is used when NFPA rod sizing is requested. 1I2" nut is used when NFPA rod sizing is requested. /\ 1I I I 1' _. TOLCO - INCORPORATED 1.20 CORONA, CA • (909) 737-5599 FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT Size Range - Pipe size to be braced: 1" through 8" Sch. 10 and 40. Pipe size used for bracing: 1" and 1-1/4" Sch. 40 IPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment com- ponent of a sway brace system: Fig. 1000 is used in conjunction with a Tolco 900 Series Fitting and joined together with bracing pipe per NFPA H3*, forming a complete sway brace assembly. Features - Can be used to brace Schedules 10 and 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector that necessary minimum torque (5 lb/It) has been achieved. Application Note - Fast Clamp need not be field assembled. Position Fast Clamp and tighten two hex nuts until leaf spring flattens. *Length of bracing pipe per National Fire Protection Association, Pamphlet #13, paragraph A-3-10.3.5: 1" Schedule 40 bracing pipe maximum 7'-2". 1-114" Schedule 40 bracing pipe maximum 9'-2". Approvals - Underwriters' Laboratories listed. Note - Must be used with Tolco U.L. Listed 900 Series attachment. Finish - Plain, Electro-Galvanized, HDG, and Stainless Steel. Order By - Order first by pipe size to be braced followed by pipe size used for bracing, figure number, and finish. / D TOLCO INCORPORATED 118 CORONA. CA • (909) 737.5599 FIG. 910 SWIVEL SWAY BRACE FITTING Size Range - 1 & 1.1/4 inch bracing pipe. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbances. The building attachment component of a sway brace system; The Fig. 910 is used in conjunction with the Fig. 1000 "Fast Clamp" (or with a Fig. 4A Pipe Clamp), and joined together with a brace pipe per NFPA #13*. Features - Universal swivel design allows Fig. 910 to be attached at any surface angle. All steel construction eliminates deficiencies associated with casting type attachments. Application Note - *Length of bracing pipe per National Fire Protection Association Pamphlet #13, paragraph A-3-10.3.5: 1" Schedule 40 bracing pipe maximum 7-2". 1-1/4" Schedule 40 bracing pipe maximum 9'.2" Approvals - Underwriters' Laboratories listed. Note -The Fig. 910 Swivel Attachment and the Fig. 1000 "Fast Clamp" (or Fig. 4A Pipe Clamp), make up a sway brace system of U.L. Listed attachments and bracing materials which satisfies the requirements of- Underwriters' Laboratories and the National Fire Protection Association (NFPA). Finish - Plain, EleotrQ-3alvanized, and Stainless Steel. Order By - Figure number, pipe size, and finish. Note - Specific weight load conditions may require more than one fastener to the building structure. Swau brace attachments may be ordered with D A? ME r10L WI SIZE A B C SIZE E F PER 100 2 1-1/2 3 9/16 2-5/16 2 88 . ..9/:16 2-5/16 ..2..5/16 1. BRECCO Brecco Corporation - - >GAUGES( GAUGES FOR USE WITH WET OR DRY SYSTEMS. GAUGES HAVE A BRONZE BURBON TUBE MOVEMENT IN A STAINLESS STEEL PLATED CASE (UNLESS OTHERWISE NOTED). 3-1/2" DIAMETER. U.L. AND F.M. APPROVED (UNLESS OTHERWISE NOTED). Pan No. Description Bo*cajj aly - GAAWSS350 AIR / WATER 0.300 PSI 60 - Wi STAINLESS STEEL CASE GMSS250 AIR W/ RETARD 250 PSI 3-Wo DIA, W/ STAINLESS STEEL 60 CASE GAWP200 2" RESIDENTIAL GAUGE 300 PSI 1 00 (NOT UI. OR F.M. APPROVED) GMWP350 AIR I WATER WI PLASTIC CASE 60 1-800543-4194 Paz: 1-877474-9248 AR AS REQUIRED bwccocorp@earthiink.net 02000 FIG. 51 FIG. 51 for NFPA Rod and Fastener Sizing Q:9 Mh INCORPORATED CORONA. CA • (909) 737-5599 41 FIG. 51 AND FIG. 52 SIDE BEAM BRACKETS (CONT.) APPROX. PIPE ROD HOLE SIZE STOCK WEIGHT SIZE - SIZE A B C H-i H-2 SIZE PER 100 1/2 -2 3/8 2 3/4 2 7/16 7/16 3/16x2 35 T4r, , - 3/4 9/6 7/16 /16x2 5-6 1/2 2.1/2 3/4 2.1/2 9/16 L 9/16 3/8x2.1/2x2.1/2 , 71 3/8.x2 1/2x2 1/2 7Q I FIG. 52 - 6 Hole Bracket APPROX. ROD HOLE SIZE STOCK WEIGHT SIZE A B C H-i H-2 H.3 SIZE PER 100 3/8x1/2 2 1-1/16 29/16 7/16 9/32 3/16x2 35 FIG. 56 TAPPED SIDE BEAM CONNECTOR Size Range - 1/2 thru 4 inch pipe (3/8 inch rod). Material - Carbon Steel Function - Practical and economical bracket used to support hangers from steel or wood beams. Can G be used with concrete shot-type inserts. Tapped hole allows easy adjustment of hanger rod. Approvals - Underwriters' Laboratories listed and E Factory Mutual Engineering approved for 1/2 . 4" A H pipe. 4( Finish - Plain, Electro-Galvanized, HDG, and F Stainless Steel. Order By - Figure number and finish. I '0 Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8 inch fastener; 2.1/2 thru 4 inch pipe use 1/2 inch lastener. ROD APPROX, PIPE SIZE HOLE SIZE STOCK WEIGHT SIZE A B C D E F G H J SIZE PER 100 1/2 -4 2-5/83/8 1 3/8 1.1/16 1-1/8 7/16 9/16 1-1/4 1/4x1 20 Schedule-1O/Schedule-40 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule4() sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (l"- 8") pipe and Sch-40.(l"-- 214") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule- 10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF'. In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. American Made Meets "Buy American" requirement and is available through distributors in the USA Canada and Mexico. Sch-40 Specifications NPS Nominal I.D. WI. WI. (1120 Fitted) Pcs/ WtlLlft (21') WIILIft (24') WVUft (25') In; mm In; mm Lbsfft; Kg/rn Lbs/Pt; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.049 1.680 2.05 70 21470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1W 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 1W 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2' 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2W 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 3[sI Specifications NPS Nomlnall.D. WI. Wt. (H20Riled) No/ WVLift(21') WIND (24') WI/Uft(25') In; mm In; mm LbslFt; Kg/rn Lbs/Pt; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1¼' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1i12" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2W 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4' 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6' 6.357 9.290 23.03 10 1,951 2,230 2:322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tqctl/F/ow Control Qr allied TUBE & coiourr @ <~> 9 Listed Approved Listed 16100 S. Lathrop • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. - Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. • Phoenix, AZ 85009 FaX 708-339-1806 S5-3 tqcci /Fire & Building I Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series LFII Residential Pendent Sprinklers 49 K-factor Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-50101(800) 877-1295 General Description The Series LFII (1Y2234) Residential Pendent Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. When aesthet- ics and optimized flow characteristics are the major consideration, the Series LFII (TY2234) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (1Y2234) has a 4.9 (70,6) K-factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (TY2234) is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Es- cutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceil- ing position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (1Y2234) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. WARNINGS The Series LFII (TY2234) Residential Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with The applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities haying jurisdic- tion. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Sprinkler/Model Identification Number SIN TY2234 Technical Data Approvals: UL and C-UL Listed. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.9 GPM/ps11'2 (70,6 LPMIbarl/2) Temperature Rating: 155°F/68°C or 175°F/79°C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame .............Brass Button .............Bronze Sealing Assembly . .......... Beryllium Nickel w/Teflont Bulb .........3 mm dia. Glass Compression Screw .....Bronze Deflector ...........Bronze Ejection Spring . . . Stainless Steel tDuPont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Page 1 of 8 JANUARY, 2003 TFP400 Page 2 of 8 TFP400 Minimum Flow (b) and Minimum Flow (b) and Minimum Flow (b) and Maximum Maximum Residual Pressure Residual Pressure Residual Pressure Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Area (a) Ft. (Max. 2 inch Rise (Greater Than 2 Inch Rise (Greater Than 4 inch Rise Ft. x Ft. (m) for 12 Inch Run) Up To Max. 4 Inch Rise for 12 Inch Run) Up To Max. 8 Inch Rise for 12 inch Run) (m x m) 155"F168°C or 155°F/68°C 175"F179°C 155°FI68C 175°F179"C 175°F179°C 12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (643 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) (3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar) 14 x 14 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) (4,3 x 43) (4,3) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar) 16 x 16 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar) 18 x 18 18 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 23 GPM (87,1 LPM) (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 22.0 psi (1,52 bar) 20 x 20 20 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 21 GPM (79,5 LPM) N/A (6,1 x 6,1) (6,1) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 18.4 psi (1,27 bar) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS Design Criteria The Series LFII (TY2234) Residential Pendent Sprinklers are UL and C-UL Listed for installation in accordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the localAuthority having Juris- diction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as speci- fied in NFPA 130 or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 130 and 13R as a function of temperature rating and the maxi- mum allowable coverage area. A minimum dischargeofo.1 gpm/sq. ft over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed with a deflector to ceiling distance of 1-3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2. NOTE So as to help avoid obstructions to water distribution, a maximum 12 inch deflector-to-ceiling distance is permit- ted for NFPA 13D and NFPA 13Rap- plications where the sprinklers are lo- cated in closets. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Beam Ceiling Design Criteria The Series LFll (TY2234) Residential Pendent Sprinklers are UL and C-UL Listed for installation in residential oc- cupancies with horizontal ceilings (i.e., slopes up to a 2 inch rise over a 12 inch run) with beams when installed in ac- cordance with the following criteria: General Information. The basic con- cept of this protection scheme is to locate the sprinklers on the underside of the beams, Ref. Figure 5, (not in the beam pockets); to identify the main beams that principally run in one direc- tion as "primary beams"; and, to iden- tify the beams that run principally per- pendicular to the main beams, as may be present (or in some cases may be necessary for proper sprinkler protec- tion), as "secondary beams". Primary and Secondary Beam Types. Solid surface, solid or hollow core, combustible or non-combustible. Primary and Secondary Beam Posi- tioning. Directly attached to the un- derside of a combustible or non-com- bustible smooth ceiling at any elevation. Primary Beam Cross-Section: Maxi- mum depth of 14 inches and the maxi- mum width is unlimited. The cross-sec- tional shape of the primary beam may be rectangular to circular. - 2-7/8" DIA. - 7/16±1/8' (73,0 mm) I 1/2"(12,7mm) (11,1±3,2 mm) 2-1/4" DIA. I 1/4(64mm) I I FACE OF mm) I SPRINKLER 1572 MOUNTING I FITTING PLATE j •3 MOUNTING SURFACE ////#//\7j (3.2 mm) 1-3/8(34,9 mm) ! CLOSURE TY2234 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY2234) RESIDENTIAL PENDENT SPRINKLER TFP400 Page 3 of 8 7/16(11,1 mm) 1/2 ESCUTCHEON _________ 2-7/8' DIA. I- Frame MAKE-IN SURFACE 2 - Button (73.0 mm) 4-Bulb -1/4" 6 - Compression 2 2 Screw Components: NOMINAL NPT PLATE SEATING _T 3 - Sealing Assembly Deflector * ' ' _________ (57,2 mm) \J Ejection Spring (41,3 mm) WRENCH STYLE 20 RECESSED I Temperature FLATS ESCUTCHEON * rating is indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 SERIES LFII (TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS Secondary Beam Cross-Section. Maximum depth to be no greater than the primary beam and the maximum width is unlimited. The cross-sectional shape of the secondary beam may be rectangular to circular. Primary Beam Spacing. The primary beams (Fig. 6A) are to be 3 ft. - 4 in. to 6 ft. from the compartment wall to cen- ter of the nearest beam and from cen- ter to center between beams. Secondary Beam Spacing. The sec- ondary beams principally run perpen- dicular to the primary beams. Secondary beams of a depth equal to the primary beam must be placed so that the beam pockets created by the primary beams do not exceed 20 feet in length (Fig. 613). NOTE When the beam pockets created by the primary beams exceed 20 feet in length, the installation will require the use of secondary beams as described above. Otherwise, secondary beams need not be present. Secondary beams of a cross-sectional depth greater than one-quarter the depth of the primary beams are to be a minimum of 3 ft. - 4 in. from the WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W- TYPE 7 RECESSED SPRINKLER WRENCH compartment wall to center of the nearest beam and from center to cen- ter between beams (Fig. 6C). Secondary beams of a cross-sectional depth no greater than one-quarter the depth of the primary beams may be placed at any compartment wall to center of the nearest beam distance / > NCH RECESS (END A" USED FOR TY2234) FIGURE 3 W- TYPE 6 SPRINKLER WRENCH Page 4 of 8 TFP400 and from any center to center distance between beams (Fig. 6C). Lintels. Lintels over doorways exiting the compartment must be present. The minimum height for the lintels is B inches or no less than the depth of the Primary Beams, whichever is greater. Sprinkler Types. Series LFll (1Y2234), 155F and 175F, Pendent and Recessed Pendent Residential Sprinklers. Sprinkler Coverage Area and Hy- draulic Design. The sprinkler cover- age areas and hydraulic design criteria as presented in the Table A for Hori- zontal Ceilings" are to be applied. Sprinkler Position. The deflector to bottom of primary beams for the Series LFII (TY2234) Pendent Sprinklers or Series LFll (TY2234) Recessed Pen- dent Sprinklers is to be 1-1/4 to 1-3/4 inches (Fig. 5A). The vertical center- line of the Series LFII (TY2234) Pen- dent Sprinklers is to be no greater than half the primary beam cross-sectional width plus 2 inches from the centerline of the primary beam (Fig 5B). NOTES Core drilllng of beams to allow the in- stallation of sprinkler drops requires consulting with a structural engineer. Where core drilling is not permitted, the previously stated sprinkler position criteria for the Series LFII (TY2234) Pendent Sprinklers allows for the sprinkler drop to be placed adjacent to the primary beam. Beam and Soffit Arrangements. A soffit is permitted to be placed around the perimeter of a compartment with the beam arrangement within the sof- fited area (Fig.7). The cross-section of the soffit may be any size as long as it does not create an obstruction to water distribution per the obstruction rules of NFPA 13 for residential sprinklers. When soffits are present, the pre- viously provided 3 ft. - 4 in. to 6 ft. "compartment wall to adjacent beam" distance for the primary and secon- dary beams is to be measured from the face of the soffit as opposed to the compartment wall. NOTE Although the distance to the beams is measured from the face of the soffit, the sprinkler coverage area is to be measured from the compartment wall. Installation The Series LFll (1Y2234) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6mm). A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Pendent sprinklers are to be installed in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series LFII Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. Recessed pendent sprinklers are to be installed in the pendent posi- tion with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- aqR 1Y2234 LO MAXIMUM TY2234 ONE-HALF BEAM WIDTH PLUS 2' (50.8 mm) FIGURES SPRINKLER POSITIONING UNDER PRIMARY BEAMS (Refer to the "Beam Ceiling Design Criteria" section) plied, slide on the Style 20 Closure over the Series LFll Sprinkler, and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 . Page 5 of 8 ALL FIGURES: -.--A A_-. A—.- DISTANCES ARE MEASURED TO COMPARTMENT 14(356mm) MAXIMUM WALL FACES AND TO CENTERLINES FOR PRIMARY BEAMS HAV- ING A 14" (356 mm) MAXIMUM DEPTH PRIMARY MAXIMUM COMPARTMENT WALLS FIGURE 6A PRIMARY BEAM SPANS UP TO 20-0 (6.1 m) A_JA -IA k A=3-4to6'-O"(1.Oto1.8m) FOR PRIMARY BEAMS HAV- SECONDARY B INC A 14(356mm) MAXIMUM BEAM DEPTH B = 204 (6.1 m) MAXIMUM FOR SECONDARY BEAMS THAT ARE TO BE EQUAL IN PRIMARY DEPTH TO PRIMARY BEAMS BEAM AND THAT MUST BE IN PLACE . SO THAT PRIMARY BEAM POCKETS DO NOT EXCEED 20'-0"(6.1 m) COMPARTMENT WALLS . FIGURE 68 PRIMARY BEAM SPANS GREATER THAN 29-0"(6.1 m) H—A - AI A— C A = 3-4 to 6-0 (1.0101.8 m) FOR PRIMARY BEAMS HAV- ING A 14" (356 mm) MAXIMUM SECONDARY . C DEPTH BEAM C = 3-4(1.0 m) MINIMUM FOR \ SECONDARY BEAMS HAVING DEPTHS GREATER THAN 25116 OF PRIMARY BEAMS PRIMARY* . —or— BEAM C = ANY DISTANCE FOR SEC- ONDARY BEAMS HAVING DEPTHS UP TO 25% OF * REFER TO PRIMARY BEAMS FIGURE 6B COMPARTMENT FOR SPANS WALLS EXCEEDING ..... , -•.•.-• -.: -... 20'-0"(6,1 m) FIGURE 6C COMBINATIONS OF PRIMARY AND SECONDARY BEAMS FIGURE 6 BEAM ARRANGEMENTS (Refer to the 'Beam Ceiling Design Criteria" section) Page 6of8 TFP400 Care and Maintenance The Series LFII (TY2234) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be,inspected, tested, and maintained by a qualified Inspection Service. TFP400 Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability.. Sprinkler Assembly: Series LFII (TY2234), K=4.9, Residen- tial Pendent Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155F/68'C or Chrome Plated .........P/N 51-201-9-155 155°F/68'C White Polyester ........P/N 51-201-4.155 155'F/68C Natural Brass ..........P/N 51-201.1-155 175Ff79'C or Chrome Plated .........P/N 51-201-9-175 175°F/79C White Polyester ........P/N 51-201-4-175 175'F/79'C Natural Brass ..........P/N 51-201-1-175 Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify) finish, P/N (specify). 1/2 (15 mm) Style 20 Chrome Plated .........P/N 56-705-9-010 1/2' (15 mm) Style 20 White Color Coated ...............P/N 56-705-4-010 1/2' (15 mm) Style 20 Bright Brass Coated ...............PIN 56-705-2-010 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Page 8 of 8 TFP400 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCO /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 A® Oem Customer Service/Sales: Tel: (414) 570-5000/(800) 558-5236 Fax: (414) 570-5010/(800) 877-1295 Series TYFRB - 2,8,4.2,5.6, and 80 K-factor Upright, Pendent, and Recessed Pend ent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping mails, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TV-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TV-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any otherauthorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.81K, 1/2NPT TY1231 - Pendent 2.81K, 1/2'NPT TY2131 - Upright 4.21K, 1/2'NPT TY2231 - Pendent 4.2K, 1/2 'NPT TY3131 - Upright 5.61K, 1/2NPT TY3231 - Pendent 5.61K, 112"NPT TY4131 - Upright 8.01K, 3/4'NPT TY4231 - Pendent 8.01K, 3/4'NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) -, . ....-, r •r ;.....:-' Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/p5i1/2 (40,3 LPM/bari12) K = 4.2 GPM/psi1/2 (60,5 LPM/bar1/2) K = 5.6 GPM/psi112 (80,6 LPM/barl'2) K = 8.0 GPM/psi1'2 (115,2 LPM/bar112) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflonf Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .........Bronze to E E 0 a. Page 1 of 8 APRIL, 2003 TFPI7I ESCUTCHEON 7/16"(11,1 mm) STYLE 10or20 PLATE SEATING NOMINAL RECESSED SURFACE kiflY MAKE-IN ESCUTCHEON 1..— W FLATS RENCH 2-7/8 (73,0 mm) DIA. RECESSED PENDENT SSP DEFLECTOR * PENDENT SSU* DEFLECTOR 6* I 7/16° I NOMINAL I : MAKE-IN 11,1mm 1 2-3/16° $ (55,6 mm) 1/2° NPT** I UPRIGHT CROSS SECTION ESCUTCHEON PLATE SEATING SURFACE T_ 2-3/16° \- (55,6 mm) 1-1/2° (38,1 mm) 7/16"(11,1 mm) STYLE 10or20 NOMINAL RECESSED MAKE-IN ESCUTCHEON 1/2° ** NPT SSP DEFLECTOR* PENDENT \[WRENCH -- FLATS 27/80 (73,0 mm) DIA. -I RECESSED PENDENT Page 2 of 8 TFPI 71 SSU* I DEFLECTOR I 61 7/160 1 5I (11,1 mm) I NOMINAL I MAKE-IN I 2-3/16 (55,6 mm) 1 1/2° NPT** t 7 UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT 7/160 (11,1 mm) 1/2 ** NOMINAL NPT MAKE-IN 6* 1 2-7/8 (73,0 mm) DIA ESCUTCHEON PLATE SEATING SURFACE 2-3/16° \T (55,6 mm) 1-1/2° (38,1 mm) SSP DEFLECTOR * STYLE 100r20 RECESSED ESCUTCHEON Ut-LUIUH mm) I NAL ;rN( ° IN 2-3/16° WRENCH (55,6 mm) FLATS 1/2' NPT STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR ..* 1/2° I (12,7 mm) I NOMINAL I MAKE-IN _4 : 2-1/4° (57,2 mm) / 3 3/4k NPT I UPRIGHT CROSS SECTION 1E I WRENCH FLATS -7/8"(73,0 mm) DIA. ESSED PENDENT TFPI7I Page 3 of 8 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 - Sealing 4 - Bulb 6 - Deflector - Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT(TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2° (12,7 mm) PLATE SEATING 3/4fl ** NOMINAL SURFACE MAKE-IN 2-5/16° NPT (58,7mm) 1-9/16° I (39,7 mm) SSP DEFLECTOR * L 2 e PENDENT REC 1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Page 4 of 8 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE IPOLYESTER 2.8 1/2 PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/57°C Orange 12,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY2231)° Figure 5 135°F/57°C Orange 1, 2, 5 155°F/681C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231)" Figure 6 135°F/57°C Orange 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 4.2 1/2° NPT PENDENT (TY2231) and UPRIGHT (TY3131) 135°F/57°C Orange 1,2 155°F/681C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PEN DENT (TY2231)° Figure 7 135°F/57°C Orange 155°F/68° C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231)°° Figure 8 135°F/57°C Orange 155°F168°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10 (1/2U NPT) or Style 40 (3/4 NPT) 3/4° Total Adjustment Re- cessed Escutcheon, as applicable. ** Installed with Style 20(1/2° NPT) or Style 30 (3/4° NPT) 1/2° Total Adjustment Re- cessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 inch (2,4 mm) for the 286°F/141 °C temperature ratings. A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ftibs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft. lbs. (13,4 to 26,8 Nm). A maximum of 30 ft lbs. (40, 7Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the TFPI7I Page 5 of 8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE 1POLYESTER LEAD COATED 5.6 1/2° PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1. 2.3,4,5.6 12,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286F/141°C Blue NPT RECESSED PENDENT (TY3231)° Figure 9 135°F/571C Orange 1,2,4,5 N/A 155°F/68°C Red 175°F/791C Yellow 200°F193°C Green RECESSED PENDENT (TY3231)** Figure 10 135°F/57°C Orange 1,2,3,4,5 I I I 1,2,4,5 I Green N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C 8.0 3/4', PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange / 1,2, 3,4,5, 6 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY4231)° Figure 11 135°F/57°C Green 1,2,4,5 N/A 155°F/68°C Orange 1751F/79°C Red 200°F/93°C Yellow RECESSED PENDENT (1Y4231)" Figure 12 135°F/57°C Orange 1,2,3,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB) as Quick Response Sprinklers; however, the LPC does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2 NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Page 6 of 8 - 2-7/8" DIA. 5/8±1/4" (73.0 mm) I 314"(19,1 mm) (15.9±6.4 mm) 2-1/4" DIA. I 1/4" (6.4 mm) I FACE OF MOUNTING I PLATE I FITTING 1/8" SPRINKLER I fm) MOUNTING SURFACE/ CLOSURE SERIES 1-5/16" (33.3 mm) TY-FRB 13/16"(20.6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8 DIA. - 5/8±1/4" (73.0 mm) 3/4(19.1 mm) (15.9±6.4 mm) 2-1/4 DIA. I 1/4(6.4mm) I FACE OF MOUNTING I SPRINKLER PLATE I FITTING _ MOUNTING SURFACE CLOSURE / .i. SERIES 1-1/4" (31.8 mm) TY-FRB 3/4" (19.1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I - 2-7/8 DIA. 1/2±1/8" I (73,0 mm) 1/2"(12,7 mm) r (12,7±3.2 mm) 2-1/4" DIA. 1/4" (6,4 mm) SPRINKLER PLATE I FACE OF 157.2 mm) -1 MOUNTING I FITTING (3.2mm) I ______ I CLOSURE SERIES 1-5/16'. _______ 1/8" I ftMOUNTING SURFACE (33,3 mm)l TY-FRB 1-1/16"(27.0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - (73.0 mm) 1/2±1/8" I 1/2(12,7mm) r (12.7±3.2 mm) 2-1/4" DIA. 1/4'(6.4 mm) I I FACE OF MOUNTING _ I SPRINKLER PLATE I FITTING 1/8" (3.2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4(31,8 mm) 1 TYFRB 1"(25.4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFPI7I - 2-7/8" DIA. - 5/8±1/4" (73.0 mm) 3/4(19.1 mm) (15.9±6.4mm) - 2-1/4" DIA. 1/4(6,4 mm) ] FACE OF MOUNTING SPRINKLER PLATE FITTING (3.21 MOUNTING SURFACE/ SERIES 1-1/4(31.8mm) CLOSURE TY-FRB iv (19.1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4" (73.0 mm) I 314"(19.1 mm) - (15.9±6.4 mm) 2-1/4 DIA. 1/4"(6.4 mm) I I I (57.2 MOUNTING FACE OF SPRINKLER PLATE FITTING 1(8" _ __________ (3.2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16"(333 mm) TYFRB 13116"(20.6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 7 of 8 2-7/8 DIA. (73.0 mm) I 1/2±1/8" I 1/2"(12,7 mm) r (12.7±32 mm) 2-1/4" DIA. I 1/4'(6.4 mm) I I SPRINKLEqR PLATE I FACE OF mm) MOUNTING FITTING 1/8 __________ I \ MOUNTIN SURFACESERIES 1-1/4(31.8mm) CLOSURE TYFRB 1'(25.4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73.0 mm) I 1/2(12.7mm) I r (12.7±3.2 mm) 2-1/4" DIA. I 1/4" (6.4 mm) I I I (57.2 I FACE OF MOUNTING I SPRINKLER I PLATE I I FITTING (3.2 " __ 1/8 mm) //#_ 4 I \ MOUNTING SURFACE CLOSURE SERIES 1-5/16"(33,3 mm TY-FRB 1-1/16"(27.0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4' NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH - - WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH P/N 57- XXX MODEL/SIN IPERATU RATING I l Page 8 of 8 TFPI7I 330 2.8K UPRIGHT (1/2NPT) TY1131 331 2.8K PENDENT (1/2NPT) 1Y1231 340 4.2K UPRIGHT (1/2'NPT) 1Y2131 341 4.2K PENDENT (1/2NPT) 1Y2231 370 5.61K UPRIGHT (1/2"NPT) 1Y3131 371 5.6K PENDENT (1/2°NPT) TY3231 390 8.0K UPRIGHT (3/4'NPT) TY4131 391 8.0K PENDENT (3/4'NPT) TY4231 SPRINKLER 1 NATURAL BRASS 4 WHITE POLYESTER 9 CHROME PLATED 7 LEAD COATED 135 1 135"F/57°C 155 155°F/68°C 175 175°F/79"C 200 200°F/93"C 286 286°F/141"C TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2' (15 mm) Style 10 Chrome Plated .........P/N 56-701-9-010 1/2' (15 mm) Style 10 White Color Coated ................PIN 56-701-4.010 1/2' (15 mm) Style 10 Brass Plated ...........P/N 56-701-2-010 1/2' (15 mm) Style 20 Chrome Plated .........P/N 56-705-9-010 1/2' (15 mm) Style 20 White Color Coated ................P/N 56-705-4-010 1/2' (15 mm) Style 20 Brass Plated ...........P/N 56-705-2-010 3/4'P(20 mm) Style 30 Chrome Plated .........P/N 56-705-9-011 3/4' (20 mm) Style 30 White Color Coated ................P/N 56-705-4-011 3/4 (20 mm) Style 30 Brass Plated ...........P/N 56-705-2-011 3/4" (20 mm) Style 40 Chrome Plated .........P/N 56-700.9-010 3/4 (20 mm) Style 40 White Color Coated ................P/N 56-700-4-010 3/4' (20 mm) Style 40 Brass Plated ...........PIN 56-700-2-010 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqcol Flow I Tyco Fire Control I Products BlazeMaster',? FIRE SPRINKLER PIPE & F:rnNGs SUBMITTAL SHEET Tyco ARE PRODUCTS 451 North Cannon Avenue Lansdale Pennsylvania 19446 wwwtyco-flr.com TECHNICAL SEH&%S5 Tn.. (800) 381-9312' FAX (800) 7914500 E-MAIL: techseWtycofp.Cam NO. 19-1.5 TD9IS 4-1.1.20 9/2001 Tee Part No. Size Sch. 1/0 I Wt. 80000 3/0 40 /° 1 0.11 lb. 80001 1° 40 3/40 0.19 lb. 80002 11/4' 40 'I" 0.26 lb. 80003 11/20 80 1° 0.51 lb. 80004 20 80 1/." 0.90 lb. 80005 21!2" 80 V/,6" 1.59 lb. 80006 3° 80 1"/ie1. 2.41 lb. 'Part' I -No. I Size I Sch. I I 1/0 iWtl lb. I 1112 F 80015 I 1 " X/4° I 40 I "/ie" 1 "/,.' 10.28 Cross Part No.1 Size Sch. 1/0 I Wt. 80009 3/lI 40 6/0 0.13 lb. 80010 1" 40 0.23 lb. 80011 1V4° 40 16/,iU 0.34 lb. 80012 VI? 1 801 V/Is" 0.67 lb. 80013 2° 80 1/.° 1.00 lb. 80014 22 80 1ne" 1.91 lb. 80008 3°1 80 - 11 'Sh-a 2.89 lb. _ Reducing Cross 1. --if r91 41 Qfl $ £0c4yco ie Pructs (TFP) BlazeMastet CPVC pipe and 90 fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at Technical Data SIZeR: 3/40 - 3 Maximum Working Pressure: 175 psi Approvaim UL, FM, CUL, NSF, Dade County, LPCB, MM, and the City of Los Angeles Note., See aanw,tTFP BzeMeeter histallalion Indftaons and Tethnl Manual, for exact ltinglappiova1 infoimalion Pine arr1I1ey prb heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass Inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. Mare Sourcei U.S.A. Material: Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80) Golan Orange Nom.Pipe Size Avg. 0.D. inches Avg. LD. Inches Wt. Llis,/Ft. Wt. No filled Pipe Lbs fft. Ft. of Pipe per Lift Wt. per LIft Lbs. 3/40 1.050 0.874 0.17 0.43 7875 1413 1" 1.315 1.101 0.26 0.67 5040 1320 V/4° 1.660 1.394 0.42 1.07 2835 1191 10/20 1.900 1.598 0.55 1.40 2205 1136 2' 2.375 2.003 _0.86 2.20 1260 1063 2 1/20 2.875 -2.421-_1.26 3.22 1215 1531 3" 3.500 2.952 - .87 4.79 72b 1 1344 Fittings 450 Elbow - 1L!TO 5 i~ 90- Elbow i:4 lBl' __7 Part Part No. Size Sch. T/O Wt. 80050 /4 3/4" 40 /" 0.08 lb. 80051 10 40 3/11 0.11 lb. 80052 1114° 40 3/0 0.20 lb. 80053 1 Will 80 1 'lie" 0.31 lb. 80054 80 5/ 4 1 0.56 lb. 80055 21!2" 80 3/40 0.89 lb. 80056 80 1" 1.19 lb. 'Part I No. l Siz I e I I' h. I I 1/0 lwt.I u I I lb.l 1112 180032 1° x 3/401 40 1 '%.' 1 0.16 Part No. Size Sch. T/O Wt. 80025 3/41 40 /is" 0.09 lb. 80026 1' 40 3/41' 0.14 lb. 80027 11/4' 40 7/60 0.21 lb. 80028 1'/2" 1 80 1V,e' 0.40 lb. 80029 2° 80 11!4" lb. 80030 2Vs° 80 11/20 !*79 3° .14 lb. 80031 80 1/,?.82 lb. : : . ...• . ... .... .. . .. . .. . Coupling -EEF-- Cap LII Part No Size Sch. TIC Wt. 80100 3/4" 40 'I." 0.04 lb. 80101 40 3/s" 0.06 lb. 80102 11/4° 40 I/al 0.10 lb. 80103 11/2" 80 6/ 0.20 lb. 80104 80 5/i" 0.31 lb. 80105 2'I2" 80 7/6" 0.58 lb. 80106 3° 80 1'TO 8-8 lb. Tb Grooved _____ Coupling -..-.. PIpO.D. Adapter Part No. Size Sch. T/O Wt. Pipe CD 80160 11I4" x 11/4" Grooved 40 0.78 lb. 11/4" (1.660') 80161 1'/a" x 11Ia" Grooved 80 2/i." 0.95 lb. 11/2" (1.900") 80162 2° x 2" Grooved 80 2/,e" 1.42 lb. 2" (2.375") 80163 21/2" x 2'/a" Grooved 80 2'I,e" 2.28 lb. 2'/2" (2.875") 80164 3" x 3° Grooved 80 2'/4" 3.00 lb. 3'(3.500') 80168 3" x 76.1 mm Grooved 80 21/4" 2.72 lb. 76.1mm (3.000") Part No. Size Sch. 1/0 Wt. 80200 1" x '/'." 40 Vise 0.04 lb. 80201 116" x /" 40 0.11 lb. 80202 11I4° x 1" 40 5/,11 0.12 lb. 80203 11/2" x 3/4"80 °k" 0.16 lb. 80204 11/2" X 1" 80 the 0.14 lb. 80205 11/2" X 11/4" 80 3/11 0.17 lb. 80206 2" x 3/4" 80 3/4" 0.27 lb. 80207 2' x 1° 80 "/." 0.26 lb. 80208 2° x V/4" 80 /t." 0.24 lb. 80209 2" x 11/2" 80 7/," 0.19 lb. 80215 The x 1" 80 Vohs" 0.42 lb. 80214 21/2" x 1',." 80 1/4" 0.45 lb. 80213 21l2" X 11/2" 80 1/." 046 lb 80211 2'/z° x 2° 80 1°!,." 0.29 lb. 80210 3" X 2° 80 2 0.72 lb. 80212 3" X 21/2° 80 116/i," 0.47 lb. ,-J Reducing Td Tee Tb' Part No Size Sch. T/O Wt. 80075 3/4° 40 V." 0.07 lb. 80076 1" 40 'I." 0.11 lb. 80077 1'/4" 40 3/,11 0.12 lb. 80078 V/2" 80 3he° 0.25 lb. 80079 2° 80 3/," 0.38 lb. 80080 2'I2° 80 3/,11 0.67 1b. 80081 3" 80 3/" 0.91 lb. Reducer Bushing T/O Female Adapter Part No. Size Sch. 1/0 I Wt. 80142 3/411 X 3/4' NPT 40 0.41 lb. 80145 x 1" NPT 40 W' 0.63 lb. 80146 11/4" X 11/4" NPT 40 7/i" 1.03 lb. 80147 1'/a" x V/a" NPT 80 1" 1.42 lb. 80148 x 2" NPT 80 1/.' 2.68 lb. ldo Male Adapter Part No. Size I Sch. 1/0 wJ 80157 /" X 3/40 NPT 40 1/'e" 0.33 lb. 80158 1" x 1° NPT 40 1/." 1 0.56 Ibi Reducing . ..- Coupling I PartNo.1 Size lSch.IT/01 Wt. 80220 1" x 3/4" 40 I 'I." 1 0.08 lb. Part No. Size - Sch. T/O Wt. lb. 1 2 3 80132 1 3/4" X 3/I' x 1" 40 3/4" 3/411 6/i" 0.14 80133 1" x 3/4 X 3/4" 40 ¼" "lie" 3/ 0.14 80134 1"x 3/4"x 1" /U xl" 40 6/," 3/ 4 11 3/4' 0.17 80260 x 1" x 3/4"40 3/4w I/4 "I,." 0.16 80135 11/4" X 1" x 3/4" 40 'I,." 3/4" '/." 0.21 80136 11/4"x 1" x 1" 40 "I,." 3/4" "/." 0.22 80137 11/4" x 1" x 11/4° 40 i3/,° I I5/," 3/ieuu 0.26 80261 11/4"x 11/4" X 3/4 40 6/," /," ?/" 0.23 80262 11/4" X 11/411 x 1" 40 l4" 3/4 'I." 0.26 80138 11/4" X 11/4" X 11/2" 80 1" 1" 1" 0.43 80140 11/2" X 11/4" X 3/4" 80 /a 6/' 1" 0.36 80141 1 '/2" X 11/4" X 1" 80 'Ia" '/." 1 the 0.38 80263 11/2" X 11/2" x l4" 80 1i." 'I,." 1" 0.36 80264 11/a" X 11/2" x 1" 80 5/,, °/,." 1" 0.38 80275 11/2" X V/a" X 11/4" 80 'I." 'I," 1" 0.45 802661 x 2" x she 80 3/4fl '14' /4 1/e" 0.61 80266 2" x 2" X 1" 80 'I." 'I," 1 she 0.66 80274 2" x 2" X 11/4" 80 - 1° - 1" - 1/." - 0.74 - 80267 2° x 2" X 1'la" 80 1'/e" VI." 1/." 0.78 80271 21/2" x 21/2" x 1" 80 1 '!,.'1 1"iie"" 1'!,." 1.43 80272 21/2"x 21/2" X 1114' 80 1"!16" 1"/,e" 1/i." 1 1.46 80273 21/2" x 21/" X 11/2" 80 1 "1,0° 1 "Ii." 1 'li." 1.48 80276 21l2" X 2¼" x 2" 80 1"!,.' 111!,." 1/,e" 1.50 80270 3" X 3" X V/a" 80 1/4" 1/4" 1'/,." 2.28 80268 3" x 3"x 2" 80 1/" 1/4" 1/4" 2.25 80269 3" x 3" x 21I2" 80 1/4" 1/4" r 1 'eli." 2.44 T/O Sprinkler Head Adapter - with Brass Threaded Insert _______ Fart No. I Size i75 wt. 80175E 1 is" X 1/2" NPT 80 7/,," 0.20 lb. 80176E 1"x ½" NPT 80 0:22 lb. 80177L 3/4" X /2'• NPT 40 'I'." 0.16 lb. 80179 1 x 3/4" NPT 1 40 3/' 0.43 lb. roe!I Part No. Size I Sch. I T/O Wt. 80177L 3/4" x '/2" NPT 40 1/2 0.16 lb. 80178 1" x 1/2" NPT 40 ½" 0.20 lb. Sprinkler Head Adapter _.... with Brass Threaded Insert I Part No. Size Sch. T/O I Wt. I 80175W 3/4"X /2" NPT 40 T/,,n 1 0.19 lb. [80176W 1" x '/" NPT 40 1/,,' 1 0.18 lb. Part No. Size Sch. I/O Wt. lb. 1 2 80462 1" x 1" x 1/2" NPT x 'Ia" NPT 40 6/," 1'!." 0.46 80463 1" X 1° X 'Ia" NPT x t/fl NPT 40 'I." 1'/,." 0.47 Sprinkler Head Adapter (Spigot) with Brass Threaded Insert Back-to-Back Cross with Brass Threaded Insert Sprinkler Head Adapter 90° Elbow with Brass Threaded Insert Back-to-Back Tee with Brass Threaded Insert Part • No. Size Sch. T/O Wt. I lbj 1 1 2 80199 3/4 x /2" NPT .40 '/," "I,." 1 0.20 80189 1"x /2" NPT 40 I3/,, 0.26 Sprinkler Head Adapter T!ct Tee -..--. with Brass Threaded Insert I - I.. LImited Warranty Part No. Size Sch. I/O I Wt. lb. 1 T-2-1 80459 1" x 1/2" NPT x 'Ia" NPT 40 "/." 15/is° 0.48 80460 1" x 'Ia" NPT x 1/2° NPT 40 ii/,,n 1'/." i 0.46 Part No. Size Sch. I/O . Wt. lb. T 1 2 3 80250 3/4fl x 3/4" x 'Ia" NPT 40 '/." '/.' 0.22 80251 1"x 1" x 'Ia" NPT 40 "/." "I,," I3/,,n 0.29 80249 1"x 1" x 1" NPT - 40 "It." "/,." 17I,." 0.73 80256 1'/4" X 1" X ½" NPT . 40 7/,," '/." 1'!." 0.30 80252 11/" X 11/4' X Va" NPT 40 1/,, 7/,,' 1'!." 0.31 80257 1'/a"xi'/"x'/"NPT T 80254 11/2 X 11/2" X 1/2 NPT 80 'I,." 'I,." . VI,." 0.46 80258 Ia 2" x i'Ia" x '" NPT 80 'Ia" 'I." 1'!." 0.56 80253 2" x 2" x '/" NPT 80 '/2" 'Ia" 1'/." Q6 Products manufactured by Tyco Fir. Products are warranted solely to the original Buyer for ten (10) years against defects In material and workmanship when paid for and properly Installed and maintained under normal use and service. This warranty will expire top (10) years from date of ih1pnont by Tyco Fire Products. No warranty is given for products or components manufactured by compact., not affiliated by ownership with Tyco Fire Product, or for products and components which have been subject to misuse. Improper installation, corrosion, or which have not been Installed, maintained, modified or repaired In accordance with applicable Standards of the National Fire Protection Association (NFPA). and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products mole option. Tyco Fire Products neither asiumes. nor authorizes any person to assume for It any other obligation In connection with the sal, of products or parts of product.. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or Incomplete Information supplied by Buyer or Buyer's representatives. UI NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT. TORT. STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY. FOR INCIDENTAL. iNDIRECT. SPECIAL OR CONSEQUENTIAL DAMAGES. INCLUDING BUT NOT LIMITED TO LABOR CHARGES. REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES. AND UI NO EVENT SNAIL TYCO FIRE PRODUCVS LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABilITY AND FITNESS FOR A PARTICULAR PURPOSE. tqco/Rowconzro// ?y0o8Mo#4 1mi.3 VVE xd I"MtMO od M0M0? c5