HomeMy WebLinkAbout5939 DARWIN CT; ; AS070049City of Carlsbad Sprinkler Permit Permit No: AS070049 Job Address: 5939 DARWIN CT Permit-Type: SPRINK Parcel No: 2121201600 Lot #: 0 Reference No.: Status: ISSUED Applied 3/5/2007 Approved: 3/14/2007 Issued:' 3/14/2007 PC #: Inspector: Project Title: SALIENT NETWORK T.I. FIRE SPRINKLER PLAN CHECK & INSPECTION Applicant: Owner: COSCO FIRE PROTECTION MORGAN-ALTON .LTD 10695 TREENA ST C/O JOHN SPENCER SAN DIEGO, CA 15375 BARRANCA PKWY #E102 IRVINE CA 858-444-2000 Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 San Diego Branch Office .00... 1 cosco 10695 Treena Street., Suite #105 "•I•• San Diego, CA 92131 '..• i Fire Protection (858) 444-2000 fax: 444-2056 Stale License No: C-16-577621 www.coscofire.com MATERIAL SUBMITTAL Date: 2-26-07 SALIENT NETWORK 5939 DARWIN CT STE A CARLSBAD, CA 92008 JOB# 1O•CD5079 All material submitted, maybe substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: H. VILLEGAS Los Angeles • San Francisco • Orange • Fresno • San Diego • Seattle A56qCo49 August 4, 2006 Sprinkler 41 a PRODUCT NAME MICROFAST5 AND MicrofastHP5 QUICK RESPONSE PENDENT SPRINKLERS tThe Sprinkler Identification Number (SIN) is stamped on the sprinkler deflector. MANUFACTURER THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (269) 945-9501 Technical Services: (877) 384-5464 Fax: (269) 945-9599 e-mail: techsvcsvikingcorp.com PRODUCT DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small thermosensitive glass bulb spray sprinklers available in various finishes, temperature ratings, and orifice sizes to meet design requirements. The special Poly finishes and Teflon® coatings can be used in decorative applications where colors are desired. In addition; these finishes have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Poly finishes as corrosion resistant.) The pip cap and sealing assembly of the sprinkler are held in place by the glass bulb operating element. During fire con- ditions, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. TECHNICAL DATA LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 Refer the Approval Chart on page 41 c and Design Criteria on page 41 d for cULus and FM approval requirements that must be followed. CHARACTERISTICS Minimum Operating Pressure: 7 psi (0,5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0,5 bar) up to 250 psi (17,2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 176 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34,5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-5 °C) Overall Length: Refer to the Approval Chart MATERIALS Frame Casting: Brass UNS-C84400 Deflector Brass UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Note: Units of measure in parentheses may be approximations. Replaces page 41 a-b, dated November 18, 2005 (Reformatted; added Form No. F_081296 135 °F temperature rating, and added CE approval for sprinkler 0666613.) ,Sprinkler 41 b . August 4, 2006 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 "F (57 "C) 100 "F (38 "C) Orange Ordinary 155 "F (68 "C) 100 "F (38 "C) Red. Intermediate 175 "F (79 "C) 150 ¶ (65 "C) Yellow Intermediate 200 "F (93 "C) 150 "F (65 "C) Green High 286 "F (141 "C) . 225 "F (107 "C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester (White Poly finish for Sprinkler 06662B), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® Corrosion-Resistant Coating83: White Polyester (White Poly finish for Sprinkler 06662B only), Black Polyester (Black Poly finish for Sprinkler 06662B), and Black Teflon® 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on page 41 c. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Poly finishes and Teflon® coatings.. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-Cil 000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Poly Coated Sprinklers: Belleville Spring-Exposed AVAILABLE FINISHES AND TEMPERATURE RATINGS: Refer to Table I above. 5. ORDERING INSTRUCTIONS (Also refer to the current Viking price list) Order Microfast® Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Poly Finish = M-M Black Poly Finish = M-/B, and Black Teflon® = N Temperature Suffix ("FrC): 1350I68" =A, 1550I68° = B, 175"179" = 0, 200°I93" = E, and 286"I141° = G For example, Sprinkler VK302 with a 1/2" thread, Brass finish and a 155 7168 'C temperature rating = Part No. 06662BAB. ACCESSORIES (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: Recessed pendent sprinklers with protective caps must use wrench 12144W1B. **A 1/2' ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) August 4, 2006 Sprinkler 41 c MEM Nominal Listings and ApprovaI93 Base Part Thread Size pOvemil Length" 'a SIN d.)q esig Cr 0 p Number NPT I BSP U.S. I metric2 Inches I mm cULu34 I FM 5 I NYC6 IVdSILPCBl CE I Standard Orifice 06662B I VK302 I 1/2' 115 mm I 5.6 I 80,6 I 2-1/4 I 58 JAIX, B1YIA4X, B4YIAIX, B1YI F2 I A4X 1C4X, D4Y121 C4X, D4Y14 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115,2 2-3/8 1 60 A3X, B3Y A2X, B2Y A3X, B3Y - - E412 - 12104 .VK352 3/4° 20 mm 8.0 115,2 2-1/4 1 58 1 - - - F2 - - - 06765B VK352 1/2" 115mm 8.0 115,2 1 2-3/8 1 60 IA3X,B3YI - A3X, 133Y - - -- ________ Small Orifice8 06718139 VK329 1/2" 15 mm 2.8 40,3 2-3/16 56 A3X, B3Y A2X JA3X,B3YJ - - - - 06720139 VK331. 1/2" 15 mm 110mmF4.2 4.2 60,5 1 2-1/4 58 IA3X,B3Y - A3X, B3Y - I - - 0.932B VK331 - 60,5 2-3/8 60 1 - -. - F2 - F213 - Maximum 250 PSI (17,2 bar) WWP __ Standard Orifice Base Part Thread Size Nominal Overall Length Listings and Approvals3 Number SIN K-Factor (Refer also to Design Criteria on page 41 d.) NPT I BSP U.S. I metric2l Inches I mm cULus4 FM I NYC1° VdS I LPCB I CE 12282 VK317 1/2". 15 mm 5.6 80,6 1 24/4 1 58 A3X, 133Y - A3X - - - - Maximum 250 PSI (17,2 bar) WWP Small Orifice8 122909 I VK342 I 1/2" 15 mm I 2.8 I 40,3 2-3/16 I 56 IA3X, B3YI - I A3X I Approved Temperature Ratings A -135 °F (57 °C), 155°F (68 °C), 175°F (79 "C), . Approved Escutcheons 200 °F (93 °C),.and 286 "F (141°C) Approved Finishes X - Standard surface-mounted escutcheon B -135°F (57 °C), 155°F (68 °C), 175°F (79 °C), I - Brass, Chrome-Enloy®, White Poly Finish7, or the Viking Microfast® Model F-i and 200 "F (93 °C) Black Poly Finish7, and Black Teflon57 Adjustable Escutcheon" C -155°F (68 °C), 175°F (79 °C), 200°F (93 °C), 2 - Brass and Chrome-Enloy® Y - Standard surface-mounted escutch- and 286 °F (141°C) 3 - Brass, Chrome-Enloy®, White Polyester7, eon or the Viking Microfast® Model D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F Black Polyester7, and Black Teflon®7 F-I Adjustable Esutcheon1' or re- (93 °C) 4 - Brass, Chrome-Enloy®, White Poly Finish, cessed with the Viking Micro- E - 155 °F (68 °C), 175 °F (79 "C), and 286 °F and Black Poly Finish matic® Model E-1 or E-2 Recessed (141°C) Escutcheon F 7 155°F (68 "C) Footnotes 1. Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 5Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. ° Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. The sprinkler orifice Is bushed. "Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol XVI. "The Viking Microfast® Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 12 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 C K Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130. 14 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-I 008. Wrench 12144W/B** for installing coated and/or recessed sprinklers with protective caps.. Carefully slide the wrench sideways around the protective A 1/2 ratchet is required cap, ensuring engagement (not available from Viking). with the sprinkler wrench flats. Sprinkler 41 d August 4, 2006 cULus Listing Requirements: Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklerimust be followed. FM ADoroval Requirements: Quick Response Pendent Sprinklers are FM Approved as indicated in the Approval chart for use only, in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems). For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-2 for general care, installation, and maintenance information. Viking sprinklers are to be installed In ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, Assemblee Pleniere, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Wrench Fiat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Figure 2: Wrench 12144W/B for Installing Coated and/or and Recessed Pendent Sprinklers 1-3/4' (44,5 mm) ,August 4, 2006 Sprinkler 41 e Ceiling Opening Size: 2-5/16"(59 mm) Minimum, 2-1/8' 2-1/2' (64 mm) Maximum. (54 mm) 1/2' NPT Ir (44,5 mm) Pendent Sprinkler 06662B Pendent Sprinkler 06662B Installed with a Standard 1/8' (3,1 mm) Surface-Mounted Escutcheon 2' (50,8 mm) (38,1 mm) Maximum Minirum Pendent Sprinkler 06662B Installed with the Microfast® Model F-i Adjustable Escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: I- I 2-1/8' I 2-5/16" (59 mm) Minimum, I 2-1/8' (54 mm) 2-1/2' (64 mm) Maximum. (54 mm) 1-3/4" Minimum I 1-1/8' (28,6 mm) (44,5 mm) Maximum Pendent Sprinkler 06662B Installed with the Micromatic5 Model E-1 Recessed Escutcheon 1-1/8' (28,6 mm) (50,8 mm) Minimum' Maximum 22 ____________ Pendent Sprinkler 06662B Installed with the Micromaffc' Model E-2 Recessed Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons THIS PAGE INTENTIONALLY LEFT BLANK Replaces page 41 a-b, dated November 18, 2005 (Reformatted, added Form No. F_081296 135 T temperature rating, and added CE approval for sprinkler 0666613.) tqCLP IF/re & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series EC-1 I & EC. 14 - 11.2 and 14.0 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Rec. Pendent Sprinklers General Description The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as com- pared to the maximum coverage area of 130 ft2 (12,1 m2) for standard cover- age Sprinklers used in ordinary haz- ard occupancies or 225 ft2 (20,6 m2) forstandard coverage sprinklers used in light hazard occupancies. The Series EC-11 and EC-14 Sprin- klers feature a UL and C-UL Listing that permits their use with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than stand- ard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNINGS that provides cautions with respect to handling and instal- latiön of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect.to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hay- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be. contacted with any questions. SEPTEMBER, 2004 Model/Sprinkler Identification Number 1Y5137-Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.0K TY6237 - Pendent,14.OK TY5137 is a redesignation for C5137, G1894, and S2510. TV5237 is a redesignation for C5237, G1893, and S2511. TV6137 is a redesignation for C6137, G1896, and S2610 TY6237 is a redesignation fOr C6237, G1895, and S2611. TFP22O WRENCH FLAT rim Page 2 of 8 TFP22O 3/4U ** NPT 2-7/16" (61,9 mm) UPRIGHT & PENDENT 1/2(12,7mm) J NOMINAL MAKE-IN UPRIGHT ESCUTCHEONII'I SEATING SURFACE CROSS PENDENT SECTION 1 - Frame 2 - Button 3- Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector" * Temperature rating Is indicated on deflector Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 SERIES EC-Il AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR (TY5137) UPRIGHTAND (TY5237) PENDENT 14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT SPRINKLER FINISH (See Note 5) HAZARD TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE POLYESTER I LEAD COATED LIGHT Refer to Table B for UL and C-UL Sensitivity Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K=1 1.2 (TY5137) PENDENT K=1 1.2 (TY5237) K=14.0 (TY6237) 135°F/57"C Orange 1,2,3",4 155"F/68°C Red 175"F179"C Yellow 1, 2, 4 1, 2, 4 200"F193"C Green 286°F/141"C Blue REC. PENDENT K= 11.2 (TY5237) K=14.0 (TY6237) With Style 30 Escutcheon 135°F/57"C Orange 1.2,3.4 1, 2,4 N/A 155°F/65"C Red 175°F170°C Yellow 2000F/930C Green 286°F/141 "C Blue ORDINARY Refer to Table B for UL and C-UL Sensitivity Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K=11.2 &Y51 37) K=14.0 (TY6137) and PENDENT K112 (TY5237) K14.0 (TY6237) 135"F/57"C Orange 1,2.3.4 1,2,3,4 155°F/68°C Red 175°F1790C Yellow 1,2,4 2000171930C Green 256°F/141"C Blue REC. PENDENT I11.2 (TY5237) K= (TY6237) With Style 40 Escutcheon 135017/570C Orange 1, 2, 4 N/A 155"F/680C Red14.0 175°F1790C Yellow 200017/930C Green NOTES: 1.Listed by Underwriters Laboratories, Inc. (UL). 211sted by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Approved by the City of New York under MEA 177-03-E. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. "Frame and Deflector only. Listings and approvals apply to color (Special Order). ** Pendent Only. N/A: Not Available TABLE A, LABORATORY LISTINGS AND APPROVALS TFP220 . Page 3ot8 LIGHT HAZARD 135°F 155°F 175°F 200°F .286°F ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - . - - SR SR SR SR 14 x 14 Style 30 Recessed - - - - - SR SR SR SR 14 x 14 Style 40 Recessed - - - - - SR SR SR SR 16 x 16 Up. or Pend. QR* QR* OR* OR* 0R SR SR SR SR 16 x 16 . Style 30 Recessed OR' OR* OR' OR* QR' SR SR SR SR 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 18 x 18 Up. or Pend. OR* QR* QR* QR* OR* SR SR SR SR 18 x 18 Style 30 Recessed QR* QR* OR* 0R OR* SR SR SR SR 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR 20 x 20 Up. or Pend. . QR* OR* OR* SR* SR SR. SR SR SR 20 x 20 Style 30 Recessed OR* SR* OR* SR* SR* SR SR SR . SR 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable * Does not apply to Upright K = 14.0 TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-1 I OR EC-14 SPRINKLERS (SEE TABLED FOR PERMITTED K-FACTOR/AREA COMBINATIONS) LIGHT HAZARD ORDINARY HAZARD 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F AREA STYLE 14 x 14 Up. or Pend. - - - - - SR SR SR SR SR 14 x 14 Style 30 Recessed - - - - - N/A N/A N/A N/A N/A 14 x 14 Style 40 Recessed - - - - - N/A N/A N/A N/A N/A 16 x 16 Up. or Pend. OR. OR* N/A N/A N/A SR SR SR SR SR 16 x 16 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Up. or Pend. OR* OR* N/A N/A N/A SR SR SR SR SR 18 x 18 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Up. or Pend. OR. OR* N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed OR OR N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A QR: Quick Response SR: Standard Response N/A: Not Applicable . Pendent Only TABLE SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-1 1 OR EC-I4 SPRINKLERS (SEE FM LOSS PREVENTION DATA SHEET 2-8N FOR PERMITTED K-FACTOR/AREA COMBINATIONS) SR N/A N/A SR N/A N/A SR N/A N/A SR N/A N/A Page 4 of 8 TFP220 Technical Data Approvals UL and C-UL Listed. FM Approved. (Referlo Table A for complete approval information including corrosion resis- tant status. The approvals apply to the service conditions indicated in the De- sign Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 11.2 GPM/ps11/2 (161,3 LPM/bar1/2) K = 14.0 GPM/psi112 (201,6 LPM/barl12) Temperature Ratings 1350F/570C to 286°F/141 °C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel wfreflonf Bulb ........Glass (3 mm dia.) Compression Screw .......... ......Bronze Deflector ............Brass Patents U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprin- kler to activate and flow water. Design Criteria The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers must only be installed in accordance with the ap- plicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Re-cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C).. UL and C-UL Listing Requirements The Series EC-1 1 and EC-14 Sprin- klers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all of the sprinklers in the design area. The Series EC-1 1 and EC-14 Sprin- klers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13. For example: Unobstructed, combustible or non-- combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 t 12 inches (25 to 300 mm). Obstructed, non-combustible, ceil- ing construction with a deflector lo- cation below structural members of ito 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). The Series EC-1 1 and EC-14 Sprin- klers having been specifically tested and listed for non-combustible ob- structed construction are permitted to be used within trusses or bar joists having non-combustible web mem- bers greater than 1 inch (25.4 mm) when applying the 4 times obstruc- tion criteria rule defined under "Ob- structions to Sprinkler Discharge Pattern Development". The minimum allowable spacing be- tween the Series EC-1 1 and EC-14 Sprinklers, to prevent cold solder- ing, is 8 feet (2,4 m) for upright sprin- klers and 9 feet (2,7 m) for pendent sprinklers. The Series EC-1 1 and EC-14 Sprin- klers are to be installed in accord- ance with all other requirements of NFPA 13 for extended coverage up- right and pendent sprinklers. For ex- ample: obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to stor- age, etc. UL and C-UL Specific Application Listing Requirements For Installation Under Concrete Tees The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers (FY51 37, TY5237, TV6137 & TY6237) have a UL and C-UL Spe- cific Application Listing for use under concrete tees when installed as fol- lows: The stems of the concrete tee con- struction must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length ex- ceeds 32 feet (9,8 m), non-combus- tible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (251,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage up- right sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers are to be installed in accordance with the appli- cable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non-storage and/or non-flam- mable or combustible liquid) occupan- cies. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector-to ceiling distance. These criteria may differ from UL and/or NFPA criteria, therefore the de- signer should review and become fa- miliar with Factory Mutual require- ments before proceeding with design. 2-7/8" DIA. (73,0 mm) 3/4"(19,11 mm 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) I 1/8" -4: I (3,2 mm) MO UNTING PLATE cm 1-3/8" (34,9 mm) 7/8" (22,2 mm) 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE TFP22O 2-7/8" DIA. - 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) SPRINKLER ..,.J 1/8" FITTING (3,2 mm) ____ _____ __ __ MOUNTING SURFACE MOUNTING PLATE T-T CLOSURE 1-3/8" (34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 SERIES EC-1 1 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON Page 5 of 8 "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS (END "A") FIGURE 4. W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS WRENCH HEX FIGURE 5 W- TYPE 22 RECESSED SPRINKLER WRENCH FIGURE 3 SERIES EC-1 1 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON Page 6 of 8 TFP22O GROUP I ORDINARY HAZARD 0.15 GPMIFT2 GPM PSI 30 7.2 39 12.1 49 19.1 60 28.7 30 7.2 39 12.1 49 19.1 60 28.7 39 7.8 49 12.3 60 18.4 39 7.8 49 12.3 0 18.4 GROUP II ORDINARY HAZARD 0.20 GPM/FT2 GPM PSI 39 12.1 51 20.7 65 33.7 80 51.0 39 12.1- 51 20.7 65 33.7 80 51.0 51 13.3 65 21.6 80 32.7 51 13.3 65 21.6 80, 32.7 UGHT HAZARD 0.10 GPMIFT2' DESCRIPTION AREA GPM PSI TY5137((=11.2) UPRIGHT 14x14 16 x 16 30 7.2 18x18 33 8.7 20 x 20 40 12.8 TY5237 (K=11.2) PENDENT 14x14 16x16 30 7.2 18x18 33 8.7 20 x 20 40 12.8 TY6137 (K=14.0) UPRIGHT 14 x 14 N/A N/A 16x16 N/A N/A 18x18 N/A N/A 20 x 20 N/A N/A TY6237 (K=14.0) PENDENT 14x14 16x16 37 7.0 18x18 37 7.0 20 x 20 40 8.2 1 ft. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3.785 1pm' 1 psi = 0.06895 bar 1 gpm/ft2 =40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-1 I AND EC-14 SPRINKLERS Step 1. The sprinkler must be installed Installation with the deflector parallel to the mount- ing surface. Pendent sprinklers must The Series EC-11 and EC-14 Sprin- be installed in the pendent position, klers must be installed'in accordance and upright sprinklers must be in- with the following instructions: stalled in the upright position. NOTES' Step 2. After installing the Style 30 or Do not install any bulb type sprinkler!! 40 mounting plate (or other escutch- the bulb is cracked or there is a loss of eon, as applicable) over the sprinkler liquid from the bulb. With the sprinkler pipe threads and with pipe thread held horizontally, a small air bubble sealant applied to the pipe threads, should be present. The diameter of the hand tighten the sprinkler into the air bubble is approximately 1/16 inch sprinkler fitting. (1,6 mm) for the 135°F/5rC to 3/32 Step 3. Wrench tighten upright or pen- inch (2,4 mm) for the 2860F/1410C dent sprinklers using only the W-Type temperature ratings. 3 (End A) Sprinkler Wrench. Wrench A leak tight-314 inch NPTsprink!er joint tighten the recessed pendent sprin- should be obtained with 'a torque of 10 klers using only the W-Type 22 Sprin- to 20 ft.lbs. (13,4 to 26,8 Nm). A max!- kler Wrench. The wrench recess of the mum of 30 ft.lbs. (40.7 Nm) of torque applicable sprinkler wrench (Ref. Fig- is to be used to install sprinklers. ure 4 and 5) is to be applied to the Higher levels of torque may distort the sprinkler wrench flats (Ref. Figure 1). sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. TFP22O Page 7 of 8 Care and Maintenance The Series .EC-11 and EC-14 Sprin- klers must be maintained and serviced in accordance with the following in- structions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after, leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, orthe like, must be re- placed. Also, replace any sprinkler that• has a cracked bUlb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead, of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is, recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRAN71ES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Page 8 of 8 Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), (specify K-Fac- tor), (specify temperature rating), (specify Pendent or Upright) Extended Coverage Sprinkler with (specify fin- ish), P/N (specify - from Table E, where app!icable). Recessed Escutcheon: Specify: Style (specify 30 or 40) Re- cessed Escutcheon with (specify fin- ish), P/N (specify). Style 30 Recessed Escutcheon Chrome Plated ............PSN. 56-705-9-011 White Color Coated ........PSN 56-705-4-011 White (RAL9O1O). ......... PSN 56-705-3.011 Brass Plated .............. PSN 56-705-2-011 Style 40 Recessed -Escutcheon Chrome Plated ............PSN 56-700.9-010 White Color Coated ........PSN 56-700-4-010 White (RAL9010) .........PSN 56-700-3-010 Brass Plated ..............PSN 56.700-2-010 Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, PIN 56-895.1-001 Specify: W-Type 22 Recessed Sprin- kler Wrench, P/N 56-665-7-001 TFP22O P/N 51 - AAA - B -CCC AAA = 893 (for TV5237 Ki 1.2 Pendent) AAA = 894 (for 1Y5137 K11.2 Upright) AAA = 895 (for TY6237 K14.0 Pendent) AM = 896 (for TV6137 K14.0 Upright) B = 1 (for Natural Brass) B = 3 (for White [RAL901OJ)* B = 4 (for White Polyester) B = 7 (for Lead Coated B = 9 (for Chrome Plated) CCC = 135 (for 135°F/570C) CCC = 155 (for 155017/680C) CCC = 175 (for 1750F/790C) CCC = 200 (for 200017/930C) *Eastern Hemisphere sales only. TABLE PART NUMBERS FOR EC-il AND EC-14 SPRINKLERS TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 scutcheonm4 Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product UIV Description The Central Two-Piece Adjustable Sprinkler Escutcheon is designed to enhance the appearance of pendent sprinklers when installed below ceilings. The escutcheon provides a decorative closure of the annular space between the sprinkler and the ceiling. The Two-Piece Adjustable Sprinkler Escutcheon is of a telescoping type design that provides for 2" of field adjustment, thereby assuring a good fit against the ceiling. It is available in two thread sizes and three standard finishes. Additional special finishes are available upon request which require additional ordering time and a special paint charge. Technical Data Model: 401 Style: Two-Piece Adjustable Escutcheon Size: 1/211 (12.7 mm) or 9/40 (19.1 mm) N.P.T. Standard Finishes: Brass, Chrome and White Depth: Minimum: 1/8" (4 7.6 mm) Maximum: 3%" (79.4mm) Diameter: Cup: 2W' dia. (57.15 mm Skirt: 3%" dia. (88.9 mm) Weight: 2.8 oz. (79.4 grams) Inst allation The Two-Piece Adjustable Sprinkler Escutcheon is held in the proper position by being sandwiched be- tween the face of the reducing coupling and the wrench boss on the sprinkler. Installation Sequence: Step 1. The face of the reducing coupling on the drop nipple should be a nominal 2W' (±W') below the finished ceiling surface. Step 2. Prior to installation of the sprinkler, turn the escutcheon cup onto the sprinkler threads. Step 3. Hand tighten the sprinkler and cup into the reducing coupling on the drop nipple. Step 4. Wrench tighten the sprinkler to the recommended torque using the proper Central Sprinkler Wrench. Step 5. After the ceiling is in place, align the escutcheon skirt with the sprinkler and press it up and over the escutcheon cup until the outer edge of the skirt meets the ceiling surface. Cross Section - Two-Piece Sprinkler Escutcheon - 401 fl Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the model, size and quantity. Availability and Service: Central sprinklers, valves, accessories, and other products are available throughout the U.S. and Canada; and internationally through a network of. Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company or call (215) 362- 0700 for the distributor nearest you. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from the date of shipment. Please refer to the current Price List for further details of the warranty. Conversion Table: I inch = 25.400 mm Conversions are approximate. CENTRAL Central Sprinkler Company 451 North Cannon Avenue, Lansdale, PA 19446 @ 1992 Central Sprinkler Company Phone (215) 362-0700 Printed in U.S.A. FAX (215) 362-5385 401.1 SCHEDULE- 10/40 Schedule-1O/Schedule-40 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-1O/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule- lO/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (11/4"-- 8") pipe and Sch-40 (1"- 2'4") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-1O/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for thy systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcsl• WtIlJft (21') WUUft (24') WtlLift (25' In; mm In," mm Lbs/Ft;Kg/m LbsiFt;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg. 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11/4' 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51. 1,103 1,260 1,313 1W 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2.067 3.650 5.13 .30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 . 1,242 21N 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197. 1,247 ttII.i!I1hI. NPS Nominal I.D. WI. WI. (1120 Filled) Peal Wt,tlft (21') WVLIft (24') Wt,Iift (25' In; mm In, mm Lbs/Ft;Kg/m LbsiFt;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg 1" 1.097 1.400 1.81 91 2,675 . 3,053 3,185 25 27.9 2.1 2.70 91 . 1,213 1,385 1,445 11/4' 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1W 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2.157 2.640 4.22 37 2,051 2,344 . 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 2W 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 . 784 896 933 4 4260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1;160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 . 59.75 7 1,100 1,256 1,309 Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tqco/Flow control 9 allied TUBE & CONDUIT @ -<~> 9 Listed . Approved Listed 16100 S. Lathrop' Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. - Phoenix, AZ 85009 Fax 708339.1806 S5-3 2112ThJ8 NC.H PiPe Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2' thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (2/2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTm Fig. 200WON. Order By - Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/, 2/, 400 . 11 3/4 3/8 8mm or 10mm 31/, 21/2 400 11 1 3/8 8mm or 10mm 33/5 2'/, 400 12 11/4 3/8 8mm or 10mm 33/4 2/, 400 13 11/2 3/8 8mm or 10mm 37/, 2/, 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21!2 3/8 10mm 5'!. 414 600 27 3 3/8 10mm 57/8 4 600 29 3'/ 3/8 10mm. NO 51/ 600 34 4 3/8 10mm 76 5 1000 35 5 1/2 12mm 914 61!, 1250. 66 6 1/2 12mm 1014 6/4 1250 73 8 1/2 12mm 131!, 8/4 1250 136 OfficeiManufacturing FacilIty. 1315 Sampson Ave. • Corona, CA 92819 • Ph: 951.731.5599 • Fax: 951,731.0330 Customer Service • 800386.5266 wwwloko.corn Size Range - Secures 3/8° thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note — Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By — Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range — Secures 3/8" thru 7/8° hanger rod Material — Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number j) NN Fig. 99 All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/80 rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note — Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt.J100 1/4 240 215 12 318 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1'/ 11630 10370 510 OfflcelManufatharing Facility. 1375 Sampson Ave. • Comm. CA 92879 • Ph: 951.137.5599. Fax 951.731.0330 Customer Service • 800.786.5266 Wwwtolco.cain Fig. 25 Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe. Material - Steel Function - Designed to be used in conjunction with TOLCOTh Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-61-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed 9mly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 0111ceMani1aUrIng Facility '1315 Sampson Ave. • Corona. CA 92879 • Ph: 951737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 w&wi.toko.com SWG - Wood SW Page 1 of All-thread Rod, Anchoring Systems WOOD • 1/4" Rod • Horizontal Mount EJ Use #14SW Nut Driver (Item #101) Item Model Rod Shank Shank Actual Size I Diameter I Length' Shear Pullout No l 4016 1 SWG 100 1 1/4-20 1/4 1 1 1 - #14SW Item #101 300 1 SWG 200 I 1/4-20 1 1/4 J 2 1 1725# - Fir WOOD • 3/8" Rod • Horizontal Mount Note: Screws Use #14SW Nut Driver (Item #101) less than 2" in 'length will be Actual Greater than 2" Item I I Rod hank Shank UL J plated yellow. Model I PipeNo Size Diameterl Length I 'rut I Shear/Pullout are clear zinc I Load I per file://J:\Material Submittals\Hangers\SWG - Wood SW.htm ' 1/19/2007 SWG - Wood SW Page 2 of 3 (Ib) ASTMB633III Item #101 ® 18 SWG 10 1 ® 19 SWG 20 2 1250# 3 1725#-Fir ® 26+ SWG 25-380 $-16 3/8 2'/2 1500# 4 2249# - Fir 25+ SWU 30 3 Click on & symbol to link direct to UL Online Certification. Legend UL-listed. § I Available in Stainless Steel. • Box quantity 25. Standard box quantity 125, except where L so indicated. HORIZONTAL MOUNT.pdf (753 Kb) Installation Diagrams I Composite Joist• $dhtths Tnh.lwkkh fl1o3Wpn*c Consult truss manufacturer for recommended installation point. See Special Notes Installation per NFPA 13 All installations must be performed with appropriate nut drivers to comply with warranty. Installation Instructions Wood Sammy (GST).. Wood Sidewinder (SWG) Self drilling & self-tapping into wood See Figures 1-4 (vertical) and il- 14 Step 3 file://J:\Material Subrnittals\Hangers\SWG - Wood SW.htm 1/19/2007 SWG - Wood SW Page 3 of 3 (horizontal) of detailed installation instructions for more diagrams and illustrations. Step 1 Insert the appropriate nut driver into a 3/8" or V2 it portable drill: use #14 Nut Driver for GST for 3/8" and V4" rod; use #14SW Nut Driver for SWG, and for GST for %" rod. Step 2 Insert the screw into the nut driver. Now you are ready to install the screw. Position drill and begin installation: a. for installing UST, drill should be in a vertical position; b.for ins tailing SWG drill should be in a horizontal position at a right angle to the structural member. Step 4 When the nut driver spins freely on the cap of the screw installation is complete. Step 5 Screw is now ready to receive 11411, 3/8", 1/211 or metric all thread rod or bolt stock. Must be installed with appropriate nut driver to comply with warranty. Eye protection should be worn at all times when installing this product. Download CAD Drawings Installation Instructions ) Safety Information - L Juniors iL Sheetrockj Hurcane Ceiling Screws :1 Pole Tool ,J f Sammy Assortment Sammy Saddle Sammy 'press J Sammy Swivel Heap] GST -_Wood Sammy] DST- Steel Sammy J SWOR -Steel SW [ST- Concrete Samnj I SWC -_Concrete swj L-S! Wa I L Information: submit a request or contact, dpinto@itwbuildex.com Last modified: September 29, 2004 - An independent non-profit content rating organization. Copyright © 2002: ITW Buildex. All trademarks or registered trademarks used are trademarks of Sammy Super Screw®, ITW Buildex and illinois Tool Work s , Inc. fl'W Buildex Privacy Policy ITW Buildex uses WebTrends Live to analyze traffic to this web site. WebTrends Live does not create individual profiles for visitors. Unlike some tracking services WebTrends Live does not have a database of individual profiles for each visitor. WebTrends Live only collects aggregate data. For more information about WebTrends Live privacy policy, please click here. Send mail to: kehnisQ itwbuildex.com MAil' with questions or comments about the webpage. fie://J:\Material Submittals\Hangers\SWG - Wood SW.htm 1/19/2007 GST - Wood Sammy Page 1 of Home j Up =rs Ltr0 I All-thread Rod Anchoring Systems Wood Sammy - Self drilling & self-tapping into wood WOOD' 1/4" Rod • Vertical Mount Use #14 Nut Driver (Item #100 Item No Model Rod Size Shank Diameter Shank .engtli LJ #14 Item #100 20 GST .750 1/4-20 1/4 3/4 21 GST 100 1/4-20 1/4 1 22 GST 200 1/4-20 1/4 2 23 UST 300 1/4-20 1/4 3 24 GST 600 1/4-20 1/4 6 I I file://J:\Material Submittals\Hangers\GST - Wood Sammy.htm 1/19/2007 GST - Wood Sammy Page 2 of 4 WOOD • 3/8" Rod • Vertical Mount Note: Screws less than 2" in Use #14 Nut Driver (Item #100) I FM UL ULIFM [tern Model Rod Shk Shk Test Test Pipe Actual length are No Size Diam Len Load Load Size Pullout Pullout plated yellow. Qb) Qb) than 2" are clear zinc, 10 GST .75 ¼ ~ 564# - 6 Ply per STMB63311 1. 210# '16 OSB 11 GST IT 16 '4 1 3/4I 670# - Ply ® 12 GST 20 16 2 Y4 850# 940# A-2'/2 1760# - Fir EX ® 27 GST 25-380 3/8 3/8 24 1500# 4 2113#-Fir 16 ® 13 GST 30 3/8- ¼ 3 1475# 1500# 344 2060#-Fir 16 #14 403 GST 40 2180#-Fir 16 Item #100 14 GST 60 ¼ 1 6 2230#-Fir 16 Click on Q. symbol to link direct to UL Online Certification WOOD • 1/2" Rod • Vertical Mount Note: #14SW must be used for screws with W' cap. Use #14SW Nut Driver (Item #101) Item No Model Rod Size Shank Diameter Shank Length Actual Pullout 8 GST 2 V2 - 13 ¼ 2. 1760# - Fir 06 GST 2.5-380 '/2-13 3/8 2Y2 2113#-Fir #14SW Item #101 15 GST 3 1/2 - 13 ¼ 3 2275# - Fir 16 GST4 /2-13 ¼ 4 2180#-Fir 17 GST 6 1/2 - 13 'A 6 2230# - Fir Legend UL-listed § Available in Stainless Steel. Box quantity 25. Standard box quantity 125, except where so indicated. VERTICAL MOUNT.pdf (594 Kb) file:/LJ:\Material Submittals\Bangers\GST - Wood Sanimy.htm 1/19/2007 Wwd st bay WO Shock .11 CiItng 14 Consult truss manufacturer for recommended installation point. GST - Wood Sammy Page 3 of 4 Installation Diagrams Composite Joist See Special Notes Installation per NFPA 13 All installations must be performed with appropriate out drivers to comply with warranty. Installation Instructions Wood Sammy (GST). Wood Sidewinder (SWG) Self drilling & self-tapping into wood See Figures 1-4 (vertical) and 11-14 (horizontal) of detailed installation instructions for more diagrams and Illustrations. Step 1 Insert the appropriate nut driver into a 3/8" or '/2" portable drill: a; use #14 Nut Driver for GST for 3/8" and 1/4I rod; b. use #14SW Nut Driver for SWG, and for GST for 1/2" rod. Step 2 Insert the screw into the nut driver. Now you are ready to install the screw. Step 3 Position drill and begin installation: a. for installing GST, drill should be in a vertical position; b.for ins tailing SWG drill should be in a horizontal position at a right angle to the structural member. Step 4 When the nut driver spins freely on the cap of the screw installation is complete. Step 5 it Screw is now ready to receive ti , 3/811, /2 11 or metric all thread rod or bolt stock. Must be installed with appropriate nut driver to comply with warranty. Eye protection should be worn at all times when installing this product. Download CAD Drawings Installation Instructions Safety Information file://J:\Material Submittals\Hangers\GST - Wood Sammy.htm 1/19/2007 GST - Wood Sammy Page 4 of 4 -.....................-.-- .........................................................--------------------.---................. ...-....-.----.-................................ -..... .... LHorneJ Juniors. J Sheetrock Hu—i rricane L cethngscrewsj P le oI Sammy Assortment jaddle Sammy (press Sammy SwivelHead I SWG - WoodSW steeisamrnj ISteel sJ Concrete Samrnj [wc Concrete S!] L~SE , Wood J SS Steel Information: submit a request or contact, dpirito@itwbuildex.com Last modified September 29, 2004 An independent, non-profit content rating organization Copyright © 2002: ITW Buildex. All trademarks or registered trademarks used are trademarks of Sammy Super Screw®, ITW Buildex and Illinois Tool Works Inc. ITW Buildex Privacy Policy ITW Buildex uses WebTrends Live to analyze traffic to this web site. WebTrends Live does not create individual profiles for visitors. Unlike some tracking services WebTrends Live does not have a database of individual profiles for each visitor. WebTrends Live only collects aggregate data. For more information about WebTrends Live privacy policy, please click here. Send mail to: kehnisztitwbuildex.com MAIl' with questions or comments about the webpage. file://J:\Material Submittals\Hangers\GST - Wood Sammy.htm 1/19/2007 CAST IRON 90 DEGREE ELBOW NOMINAL SIZE (INCH) ITEM CODE 4 MAX. WORKING P.5.1. DIMBJSIONS WBGIrr A - B EACH PIECE 1 CB90033 300 1.50 1.50 0.95 11/4 CR90044 300 1.75 1.75 1.34 11/2 C090055 300 1.94 1.94 1.80 2 CB90066 300 2.25 225 2.90 21/2 CR90077 300 2.70 270 1 .75 1 IRON --CAST RED. COUPLING NOMINAL SIZE (INCH) ITEM CODE 4 MAX. WORKING P.S.I. DIMENSION A WEIGHT EACH PIECE 1X112 CRC031 300 1.70 0.62 1X314 CRC032 300 1.70 0.80 CASTtl1tIRON STRAI GHT TEE NOMINAL SIZE (INCH) IT CODE 4 MAX. P.SI WORKING N11.994411.994- WBGHT EACH PIECE 1 CT333 300 1.21 11/4 CT444 300 1.87 11/2 CT555 300 2.51 2 CT666 300 225 2.25 3.96 21/2 CT777 300 2.70 2.70 6.45 CAST IRON 45 DEGREE ELBO NOMINAL SIZE (INCH) I rri CODE MAX. WORKING P.S.I. D(MB4SIONS A B WBGIff I EACH PIECE 1 [CB45033 300 1.12 1.12 0.84 1 1/4 J CR45044 300 1.29 1.29 1.40 1 1/2 JB45055 300 1.43 1.43 1.80 2 CR45066 300 1.68 1.68 2.79 C.I. THREADED FITTINGS FITTINGS 4 Div,M.ofSWrPip Pruducli LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON THREADED FITTINGS ARE UL, ULC LISTED AND FACTORY MUTUAL APPROVED FOR 300 PSI SERVICE. GRAY IRON PER ASTM A126 CLASS B. DIMEN- SIONS CONFORM TO ANSI B16.4 CLASS 125 EXCEPT PLUGS CONFORM TO ASME t A B16.14. THREADS ARE NPT PER ANSI/ASME 13I.20.1. '1 A CAST 1 NOMINAL SIZE (INCH) rtBJ• CODE 4 MAX. WORKING P.S.I.AF 1DIMENSIONS WEIGHT I EACH PIECE 1X1/2 CR90031 300 126 1.36 0.64 I X3/4 CR90032 300 1.37 1.45 0.87 I 1/4X1/2 CR90041 300 1.34 1.631 0.96 1 1/4X3/4 C890042 300 1.45 1.62 1.13 1 1/4X1 CR90043 300 1.58 1.67 1.16 1 112x1 1/2 CB90051 300 1.41 1 1.66 1.17 11/2414 C890052 300 1.52 1.75 1.28 1 1/2X1 C00053 300 1: -0 1.51 1 112X1 1/4 CR90054 300 1.82 1.88 1.62 2X1/2 C890061 300 1.49 1.88 2.00 -2X3/4 CR90062 300 1.60 1.97 2.05 2X1 CR90063 300 1.73 2.02 2.10 2X1 114 C890064 300 1.90 2.10 2.30 2X1 1/2 1 CR90065 300 2.02 1 2.16 1 2.60 Page 38 CASTNlI1IRON i IPLUGS NOMINAL SIZE (INCH) I ITEM MAX. CODE WORKING 4 P.S.I. lDIMENSION I WBGIff' EACH PIECE A 1/2 CPI-001 300 0.94 0.10 3/4 CPLOO2 300 1.07 0.17 1 CPL003 300 1.25 0.28 11/4 CPLOD4 300 1.36 0.44 1112 CPL005 300 1.45 0.62 2 CPLOOG 300 1.56 0.91 C.I. THREADED FITTINGS FITTINGS . 0 * (~o <*> - LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON CROSS I NOMINAL SIZE (INCH) I ITi CODE ' MAX. WORKING P.S.I. DIMB4SIONS( WBGKT EACH PIECE A B I CX033 300 1.50 1 1.50 1.54 11/4 CX044 300 1.75 1.75 2.40 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 I 114X1 CX043 300 1.58 1.57 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 202 2.75 CAST IRON REDUCING TEE NOMINAL SIZE (INClO ITEM CODE ___ I MAX. WORKING P.S.I.P.S.I.A ' DIMB4SIONS I WBGHT' EACH PIECE B C I2 11=111211=1112 _ CT331_ 300 1.26 1.26 1W 1 0.95 IX1X3/4 CT332 300 1.37 1.37 1.41 1.10 1X112X1 CT313 300 ,r 1.08 .1X314X1 CT323 300 1W TW iö 1.18 Will 114 CT334 300 17 iT tSi r.52 1X1X1 1/2 CT335 300 -T8--O- T5 1.65 1.73 I 114X1X112 C1431 300 tW rir 1.53 1.17 1 1/4X1 X3/4 CT432 300 A5 IIT 1.62 f38 1 1I4X1X1 CT433 300 1 1 /4X1X1 1/4 1W t55• 1.57 -T.47- C1434 300 i:7r 97 175 1.80 1 114X1X1 112 CF435 300 tsr iO 1.82 2.05 1 114X1 114X112 CT441 300 TW tW 153 t37 1 114X1 1I4X314 Cr442 300 tU ir 1.62 1.54 --T UM 114X1 CT 443 300 ir 11 167 1.65 1 1/4X1 1/4X1 112 CT445 300 9W- -tr- -1.82 2.21 1 114X1 1/4X2 CT446 300 -r 2.10 1.90 255 1 1i2X1X11Z CT531 300 tr 1:w 1.56 1.41 1 112X1X3/4 CT532 300 17 1.75 1.65 1 112X1X1 CT533 300 tW 151 1.80 1.65 1 112X1X1 1/4 CT534 300 9F 9T 1.88 2.00 1 112X1X1 112 CT535 300 1W tW 1.94 2.30 1 112X1 1I4X112 CT541 300 TZ TW iss 1.58 1 1/2X1 114X314 CT542 300 9 t1' 1.75 1.72 -- 1 112X1 1/4X1 Cr543 300 -r - ir 1.80 --T.73 I 1/2x1 1/4x1 1/4 CT544 300 tyr 1.88 2.22 1 1!2x1 1/4x1 1/2 Cr545 300 TW TF 1.94 2.45 1 1/2X1 114)2 CT546 300 ii 2i0 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 iT All 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 112X1 1/2X1 Cr553 300 1.65T 1.90 1.94 1 1/2X1 1/2X1 1/4 C1554 300 11 1.81 1.88 2.29 1 112X1 1/2X2 C1556 300 216 TW 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 1 300 JL J3 1 1.88 2.09 2X1 1/2X314 CT6 1 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 TW 1.65. 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.2 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2)12X1/2 CT661 300 TW Ti 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 1 2.02 2.97 2X2X1 114 CT664 300 JQ J 2.10 332 2X2X1 1/2 CT665 1 300 ...&QL 2.02 2.16 3.72 2x2x2 1/2 CT667 1 300 J 2.6 1 2.39 1 5.10 Page 39