HomeMy WebLinkAbout234 DATE AVE; ; FA100039City of Carlsbad
Fire Alarm Permit
Permit No: FAI 00039
Job Address: 234 DATE AV Status: PENDING
Permit Type: FALARM Applied 7/7/2010
Parcel No: 2060802500 Approved: 7/7/2010
Lot #: 0
Reference No.: Issued: 7/7/2010
PC #: Inspector:
Project Title: CRESCENT DEL SOL ESTATES
Applicant: Owner:
LAGOON BREEZE DEVELOPMENT CORP
7237 SANDERLING CT
CARLSBAD CA
Fees ($) Add'l Fees ($) Total ($) Balance ($)
125 0 125 0
Crescent Del Sol Estates
Fire Sprinkler Monitoring System'
234 Date Ave Carlsbad Ca 92008
>1
C)
Plan Submittal Date 7/L/7ofC)
Spec Book
A7Q1,EO AS SUBMITTED
Zola AR BAD FIRE DEPART1ENT
1.4
FILE COPY
Honeywell
5IIOXM
FIRE ALARM CONTROL/COMMUNICATOR
Now ETL Listed to UL864 9th Edition
The 511OXM is a fire alarm control/communicator that supports five hardwired zones. It may be used as a fire detection system or a
slave Digital Alarm Communicator Transmitter (DACT), providing central or remote station service for a central or remote station listed
Fire Alarm Control Panel (FACP). It may also be used as a standalone non-coded local, central station or remote station control.
The model 511 OXM is fully supervised and supports one two-wire smoke detection circuit and four-wire smoke detectors on all five
circuits. Its microprocessor continuously monitors and reports system status of AC, standby battery, zone inputs and telephone line
connections. In the event of a fault condition, a local audible sound is activated and a report is sent directly to the central station.
FEATURES
Optional panel door mounted silence/ • Programmable via 6160 alpha Five supervised style B zones
One master code
Five user codes
Seven built-in LED indicators
One notification appliance circuit
Temporal code compliant
Supervised digital dialer
reset switch when AHJ approved
Supports two-wire compatible
smoke detector
Supports up to four keypads
Backup digital dialer built in
Auxiliary form "C' relay
Built-in warning buzzer
keypad or downloader
Supports major
communication formats
ETL Listed to UL864 9th Edition
NFPA 72 compliant
MEA Approved
Upload/download capable
APPLICATIONS
The 511OXM Fire Alarm Control/Communicator is well suited for a variety of applications as a standalone fire control or slave DACT.
A diverse line of Honeywell alarm notification appliances as well as initiating devices support this powerful control panel. Some of
the applications supported are monitoring of sprinkler supervisory or watertlow switches in factory or warehouse environments, fast
food chains, department stores, retail stores, libraries and museums as well as professional and office buildings.
INSTALLATION
The 511OXM Fire Alarm Communicator (DACT) has been designed to mount both quickly and easily. It meets all applicable
requirements for Commercial Fire installations. Remotely program and troubleshoot this panel via Honeywell's WindowsTM
based Compass Downloader.
5IIOXM
FIRE ALARM CONTROL/COMMUNICATOR
SPECIFICATIONS
Electrical
Primary power
20VAC, 60 Hz, 600mA max
Secondary rated 18VAC, 40VA
Quiescent panel current draw
155mA
Backup battery
12VDC, 7AH min to 14AH max
Lead acid battery (gel type)
Charging voltage
1 3.7VDC, nominal
Alarm power
12VDC, 1 .OA max for notification
(bell) output
Aux. standby power
12VDC, 350mA max
Total power
1 .OA from all sources
Product specifications subject to change.
AGENCY LISTINGS
The 511OXM has been listed and
approved for use in commercial fire
applications. It has been listed under the
following agency approvals:
COMPATIBLE DEVICES
Aux. relay output
Type: Form C
Standby time
24 hours with 1A standby load or 60
hours with 21QmA max standby load
using 14AH battery
Fusing
Battery input, aux. and notification (bell)
appliance circuits are protected using
PTC circuit protectors. All outputs are
power limited.
Dialers
Line seize
Double Pole
Fire
ETL listed to UL864/NFPA72 Central
and Remote Station DACT and Local,
Central Station and Remote Station
Control
Formats
Honeywell Low Speed, Honeywell 4+2
Express, Honeywell High Speed,
Honeywell Contact ID, Sescoa and
Radionics
Mechanical
Cabinet dimensions-
14.5"H X12.5"WX3"D
Environmental
.14° Fto 158° F(-10° Cto 70° C)
Operating temp
32° F to 122° F (0° C to 50° C)
Humidity
85% RH
Factory Mutual
California State Fire Marshall
MEA
Ringer equiv. EMI
0.713 • Meets or exceeds the following
requirements:
—FCC Part 15, Class B Device
—FCC Part 68
—lEC EMC Directive
See the control panel's Installation & Setup Guide for a list of compatible accessories.
ORDERING
5I10XM-9 Fire Alarm Control/Communicator
For more information: www.honeywell.com/security/hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
Melville, NY 11747 115110XM10 1.800.467.5875 September 2009 www.honeywell.com 0 2009 Honeywell International Inc.
Honeywell
~ ~ -Z zavlex-
W~,- , *-ZO rje- -12~
o5
'yAMt4
-
6160
ALPHA DISPLAY KEYPAD
WITH DOOR ATTACHED
The 6160 Deluxe Keypad is easy to install and simple to
use. The attractive white console blends with any decor and
features a contoured, removable door that conceals
illuminated soft-touch keys. The 6160 also features a new
larger and brighter 32-character display with easy-to-read
plain-English status messages.
FEATURES
I -i 1L i:•
Fs
*10 IU
- WITHOUT DOOR
The oversized function keys are easily accessed even when
the keypad door is closed, and can be programmed for fire,
burglary, personal emergencies and other operations. Colored
self-adhesive labels are included.
Large, easy-to-use keypad
Keys continuously backlit for greater
visibility
Speaker with audible beeps
to indicate:
- System status
- Entry/exit delay
- Other alarm situations
SPECIFICATIONS
Physical
5-5/16H x 7-3/8W x 1-3/16'D
(135mm x 190mm x 30mm)
Current
Standby-40mA
Activated Transmission- 160mA
Zones and system events displayed
in plain English
No confusing blinking lights
Four programmable function keys
Wiring
- (Black): Ground
+ (Red): +12 VDC (Aux. Power)
Dl (Green): "Data in" to control panel
DO (Yellow): "Data out" from
control panel
System functions clearly labeled
Functions performed by just entering
security code plus command
White with removable door blends
with any decor
Compatibility
Fully compatible with all
VISTA controls.
ORDERING
6160 Alpha Display Keypad
Honeywell Security & Custom Electronics
Honeywell International Inc.
P0 Box 9035
Syosset, NY 11791
www.honeywell.com
C006010
L/61 60/D
September 2006
0 2006 Honeywell International Inc.
Honeywell
DF-52004:A1 • F-050
BG-1 2 Series Fre.LrreALarrru
Manual Fire Alarm Pull Stations by Honeywell
ConventionalIInitiating DT!
General -
The Fire-Lite BG-12 Series is a cost-effective, feature-packed
series of non-coded manual fire alarm pull stations. It was
designed to meet multiple applications with the installer and
end-user in mind. The BG-12 Series features a variety of mod-
els including single- and dual-action versions.
The BG-12 Series provides Fire-Lite Alarm Control Panels
(FACP5), as well as other manufacturers' controls, with a man-
ual alarm initiating input signal. Its innovative design, durable
construction, and multiple mounting options make the BG-12
Series simple to install, maintain, and operate.
Features
Aesthetically pleasing, highly visible design and color.
Attractive contoured shape and light textured finish.
Meets ADA 5 lb. maximum pull-force.
Meets UL 38, Standard for Manually Actuated Signaling Boxes.
Easily operated(single- or dual-action), yet designed to pre-
vent false alarms when bumped, shaken, or jarred.
PUSH IN/PULL DOWN handle latches in the down position to
clearly indicate the station has been operated.
The word "ACTIVATED" appears on top of the handle in
bright yellow, further indicating operation of the station.
Operation handle features white arrows showing basic opera-
tion direction for non-English-speaking persons.
Braille text included on finger-hold area of operation handle
and across top of handle.
Multiple hex- and key-lock models available.
U.S. patented hex-lock needs only a quarter-turn to lock!
unlock.
Station can be opened for inspection and maintenance with-
out initiating an alarm.
Product ID label viewable by simply opening the cover; label
is made of a durable long-life material.
The words "NORMAL" and "ACTIVATED" are molded into the
plastic adjacent to the alarm switch (located inside).
Four-position terminal strip molded into backplate.
Terminal strip includes Phillips combination-head captive 8/32
screws for easy connection to Initiating Device Circuit (IDC).
Terminal screws backed-out at factory and shipped ready to
accept field wiring (up to 12 AWG/3.1 mm2).
Terminal numbers are molded into the backplate, eliminating
the need for labels.
Switch contacts are normally open.
Can be surface-mounted (with SB-10 or SB-I/O) or semi-
flush mounted. Semi-flush mount to a standard single-gang,
double-gang, or 4" (10.16 cm) square electrical box.
Backplate is large enough to overlap a single-gang backbox
cutout by 1/2' (1.27 cm).
Optional trim ring (BG12TR).
Spanish versions (FUEGO) available (BG-12LSR BG.12LPSP).
Designed to replace the Fire-Lite legacy BG-10 Series.
Models packaged in attractive, clear plastic (PVC), clam-
shell-style, Point-of-Purchase packages. Packaging includes
a cutaway dust/paint cover in shape of pull station.
Construction
Cover, backplate and operation handle are all molded of
durable polycarbonate material.
•Cover features white lettering and trim.
Red color matches System Sensor's popular SpectrAlert®
Advance horn/strobe series.
Operation
The BG-1 2 manual pull stations provide a textured finger-hold
area that includes Braille text. In addition to PUSH IN and PULL
DOWN text, there are arrows indicating how to operate the sta-
tion, provided for non-English-speaking people.
Pushing in and then pulling down on the handle activates the
normally-open alarm switch. Once latched in the down position,
the word "ACTIVATED" appears at the top in bright yellow, with a
portion of the handle protruding at the bottom as a visible flag.
Resetting the station is simple: insert the key, twist one quarter-
turn, then open the station's front cover, causing the spring-
loaded operation handle to return to its original position. The
alarm switch can then be reset to its normal (non-alarm) position
manually (by hand) or by closing the station's front cover, which
automatically resets the switch.
DF-52004:A1 • 042f08 - Page 1 of 2
Specifications
PHYSICAL SPECIFICATIONS:
pull station SB-lb SB-10
Height 5.5 inches 5.601 inches 5.5 inches
(13.97 cm) (14.23 cm) (13.97 cm)
Width 4.121 inches 4.222 inches 4.121 inches
(10.47 cm) (10.72 cm) (10.47 cm)
Depth 1.39 inches 1.439 inches 1.375 inches
(3.53 cm) (3.66 cm) (3.49 cm)
ELECTRICAL SPECIFICATIONS:
Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or
VDC.
ENGINEERING/ARCHITECTURAL SPECIFICATIONS
Manual Fire Alarm Stations shall be non-code, with a key- or
hex-operated reset lock in order that they may be tested, and so
designed that after actual Emergency Operation, they cannot be
restored to normal except by use of a key or hex. An operated
station shall automatically condition itself so as to be visually
detected as activated. Manual stations shall be constructed of
red colored LEXAN (or polycarbonate equivalent) with clearly
visible operating instructions provided on the cover. The word
FIRE shall appear on the front of the stations in white letters,
1.00 inches (2.54 cm) or larger. Stations shall be suitable for
surface mounting on matching backbox SB-10 or SB-I/O; or
semi-flush mounting on a standard single-gang, double-gang, or
4(10.16cm) square electrical box, and shall be installed within
the limits defined by the Americans with Disabilities Act (ADA) or
per national/local requirements. Manual Stations shall be Under-
writers Laboratories listed.
NOTE: *The words FIRE/FUEGO" on the BG-12LSP shall appear
on the front of the station in white letters, approximately 3/4
(1.905 cm) high.
Agency Listings and Approvals
The listings and approvals below apply to the BG-1 2 Series pull
stations. In some cases, certain modules may not be listed by
certain approval agencies, or listing may be in process. Consult
factory for latest listing status.
C(UL)US:5711
FM Approved
CSFM: 7150-0075:184
MEA: 67-02-E
Patented: U.S. Patent No. 0428,351; 6,380,846; 6,314,772;
6,632,108.
Product Line Information
BG-12S: Single-action pull station with pigtail connections, hex
lock.
BG-125L: Same as BG-12 with key lock.
BG-12: Dual-action pull station with SPST N/O switch, screw
terminal connections, hex lock
BG-12L: Same as BG-12 with key lock.
BG-12LSP: Same as BG-12L with English/Spanish (FIREI
FUEGO) labeling.
BG-12LOB: Same as BG-12L with "outdoor use" listing.
Includes outdoor listed backbox, and sealing gasket.
BG-12L0: Same as BG-12L with "outdoor use" listing. Does
not include backbox.
BG-12LA: Same as BG-12L with auxiliary contacts.
BG-12LPS: Dual-action pull station with pre-signal option.
BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE/
FUEGO) labeling.
SB-lU: Surface-mount backbox, metal.
SB-I/O: Surface-mount backbox, plastic. (Included with BG-
I2LOB.)
BG12TR: Optional trim ring for semi-flush mounting.
17003: Keys, set of two. (Included with key-lock pull stations.)
17007: Hex lock, 9/64". (Included with hex-lock pull stations.)
NOTE: For addressable BG-I2LX models, see data sheet OF-
52013.
Fire-Lite® Alarms, SpectrAlert® Advance, and System Sensor® are
registered trademarks of Honeywell International Inc.
l2008 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
Iso 9001
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
93IM1=11=1 We cannot cover all specific applications or anticipate all requirements.
IIIIIIINEE1111111 & MRIIMCURING
QUALITY SYSTEMS
All specifications are subject to change without notice. Made in the U.S. A.
For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com
Page 2 of 2— OF-52004:A1 • 04122108
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7150-0075:184 Page 1 of 1
CATEGORY: Fire Alarm Boxes
LISTEE: Fire-Lite Alarm Inc., One Fire-Lite Place, Northford CT 06472-1653
Contact: Brian Reynolds (203) 484-7161 FAX (203) 484-7309
DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-12LW, BG-I2WP, BG-I2LWP, BG-12L,
BG-I2LX, BG-12LA, BG-I2PS, BG-12LSP, BG-12SP, BG-I2LR, BG-I2LRA, BG-12LAO,
BG-I2LAOB, BG-12-LO, BG-I2LOB, BG-I2LPS, BG-I2LPSP, BG-I2SL, UT-PSI and UT-
PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally
open switch contacts. Refer to listee's data sheet for detailed product description and
operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number and UL label.
APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units.
Models BG-I2WP, BG-12W, BG-12LW and BG-I2LWP are intended for outdoor use when
installed with Model WP-I0 back box. Models BG-LAOB and BG-I2LOB are intended for
outdoor use when installed with Model WBB or WP-10 back box.
* These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and
California amendments.
.XLF: 7150-0028:199
Updated 08-17-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results
and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or
*"+ recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation
criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources.
Date Issued: AUGUST 17, 2009 Listing Expires June 30, 2010
Authorized By: FRANCIS MATEO, Program Coordinator
Fire Engineering Division
F-500
1151 and2T5?i
FireuTe® iarrns Low-Profile Plug-In Photoelectric 8
and Ionization Smoke Detectors
Section: Conventional Initiating Devices
I,.nfl lOOP
GENERAL
The System Sensor 1151 and 2151 are low-profile ionization
and photoelectric, plug-in type smoke detector heads. They
offer superb performance and reliability, meeting the stringent
performance criteria designated by UL 268 and ULC, in a pro-
file of just 1.66° (42 mm). Aesthetically pleasing to engineers,
architects, building owners and homeowners, the 1151 and
2151 can be used with four different adapter bases in a variety
of wiring configurations and voltages. Model 1151 (ionization
sensor) and 2151 (photoelectronic sensor) share the same
sleek low-profile design.
FEATURES
Sleek, low-profile design - only 1.66' (42 mm).
Same aesthetically pleasing housing design for ion and photo
models.
Two LEDs blink in standby mode, providing 3600 visibility.
Low standby current.
Field sensitivity metering of detector to meet NFPA 72 re-
quirement.
Broad range of adapter bases available - four different volt-
ages/wiring configurations.
Removable cover for field cleaning.
Sealed against back pressure air flow, dirt and insects.
Builtin tamper resistant feature.
Built-in magnetic test switch.
Head easily plugs into adapter mounting base.
Remote LED option.
Listed to UL 268.
Auxiliary relay contacts (optional).
CONSTRUCTION AND OPERATION
The 1151 Ionization smoke detector contains a unique
single-source dual-chamber design which will sense the pres-
ence of smoke particles produced by fast combustion as well
as slow smoldering fires. This chamber exhibits increased
stability, significantly reduces nuisance alarms, and provides
better performance at higher velocities.
Th2j1Phot?Iectnmoke detector contains a
unique optical 'snsingcIiâither designed to sense the pres-
ence of smoke particles produced by a wide range of combus-
tion sources. A custom integrated circuit incorporates signal
processing to help reduce false alarms.
The sensing chambers of both models are sealed from back
pressure air flow, dirt, and insects. The chambers are pro-
tected by a fine mesh screen which can be cleaned or replaced.
Additional key features include interchangeable ion and photo
heads, a variety of mounting bases, and a full line of accesso-
ries.
GENERAL SPECIFICATIONS
Operating voltage/alarm current: mounting base dependent
(see chart on page 2).
®MEA € 205-94-
0X5A4.AY LISTED
California S911 State Fire
Marshal
7271-1209:157 (1151)
7272-1209:159 (2151)
1 1151 shown with
flange-style base.
—' 2151 shown with
- flangeless baseS
Standby current: Ion (1151): 40 iA. Photo (2151): 85 iA.
Sensitivity: 1151:1.9%:t:0.62%/ft. 2151:3%:t 0.7%/ft.
Weight: 3.6 oz. (102 g).
Size: 1.66" (42.164 mm) high; 4.1' (104.14 mm) diameter for
unflangedbase; 6.1' (154.94 mm) diameter for flanged
base.
Construction: Flame-retardant thermoplastic.
Temperature: 32°F to 120°F (0°C to 49°C).
Humidity range: 10 - 93% RH non-condensing.
Air velocity: 1151 Ion: 0 - 1,200 ft. (365.76 m)/min. 2151
Photo: 0-3,000 ft. (914.4 m)/min.
A MOUNTING BASE SELECTION GUIDE is included on page
2 of this document.
JUNCTION BOX SELECTION GUIDE: Box depth is contin-
gent on base and wire size. Refer to National Electrical Code
or local applicable codes for appropriate recommendations.
Base 8401 can utilize a 50 min or 60 mm junction box. Bases
BI1OLP/RLP can utilize a single-gang, 3-1/2° (88.9 mm) oc-
tagonal, 4° (101.6 mm) octagonal, or 4' square junction box.
Bases BII2LP and B1I6LP can utilize a single-gang, 3-1/2°
octagonal, 4° octagonal, 4" square, 50 mm, 60 mm, or 75 mm
junction box. Base B114LP can utilize a 4' octagonal or 4"
square junction box.
This document is not intended to be used for installation purposes. We try to keep our product
information up-to-date and accurate. We cannot cover all specific applications or anticipate all IS09001 requirements. All specifications are subject to change without notice. For more information, ________________
contact Flre•Llte Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (BOO) 627- Sb I I
3473, Toil Free FAX: (677) 699-4105. FAX Back:(688) 3883299 1NC1NE811N1 & MANOMC1lIRIF
WEB: www.firelite.com
DF-51463 - 1'age 1 Of
RA400Z
PRODUCT LINE INFORMATION
Model Description
1151 Low-profile ionization detector (requires
B100LP Series base).
2151 Low-profile photoelectronic detector (re-
quires B100LP Series base).
1311OLP Base, 2-wire, low-profile flangeless, 12/24
VDC.
B112LP Base, 4-wire, low-profile, Form-A & -C, 24
VDC.
B114LP Base, 4-wire, low-profile, Form-A & -C + A
Supervisory, 120 VAC.
B116LP Base, 2-wire, low-profile, Form-C, 24 VDC.
RA400Z Remote annunciator for two- or four-wire sys-
tems, 3 - 32 V. Use with ion and photo plug-
in detectors. Fits standard single-gang elec-
trical box.
B401 BK Sounder base. Requires an external 24 VDC
power supply. Mounts to a 4" (101.6 mm)
square electrical box (1-1/2 [38.1 mm] mini-
mum depth, 2-1/8" [53.975 mm] recom-
mended).
MOD400R Detector sensitivity test tool. Use with most
analog or digital multimeters. Satisfies NFPA
72 requirement for sensitivity testing.
SMK400 Surface-mounting kit provides for entry of
surface wiring conduit. Use with B401 or
B401 R mounting bases only.
A77-716B End-of-line relay for power supervision, 12/
24 VDC systems.
M02-04-01 Test magnet.
XR-2 Detector removal tool. Allows installation and/or re-
moval of 100 Series detector heads from base in high
ceiling installations when used with the XP-4.
XP-4 Extension pole for XR-2. Comes in three five-foot
sections.
UrIIUI'IAL IAULI IULI1PJ'lI vvur,,i'i,
A B11OLP/RLP or B401 EOLPOWER
(+)
Wiring Diagram RELAY, iA7771o8
rii
PTIONAL.) (OPTIONAL)
() ()
COM
AUXILIARY AUXILIARY CONTACTS CONTACTS
CONTROL
LNEL r I ALARM CIRCUIT
ALARM CIRCUIT
A B112LP Wiring Diagram
(+)
_j
EOL
RESISTOR
2
10 14
1
13
NO)
10 14 COM
CONTACTS CON-
TACTS 1
-------------------------------------------------------------------------------------
OPTIONAL NFPA CLASS A WIRING
A Ell 16LP Wiring Diagram
120 VAC 120 VAC
RA400Z
O ONAL)
10 30 q
10 / 301
LJ 20 - 20 4
13
067 1
AUXILIARY FOAM C CONTACTS
AUXILIARY
FORM C
CONTACTS
-j OS
W Ix
A 131 14L Wiring Diagram
MOUNTING BASE
SELECTION GUIDE
*Functionality contingent on panel compatibility.
**Must be limited by control panel.
**Flangeless base.
RELAY CONTACT RATINGS: resistive or Inductive
(60% power factor) load. Form-A: 2.0 A at 30 VAC/
DC. Form-C: 0.6Aat 110 VDC; 2.0Aat30VDC;
1.0 A at 125 VAC; 2.0 A at 30 VAC.
Page 2of 2 - DF-51483
Base
Model
Number
Loop Current
Limit
Resistor
Alarm
Contact
Type
Nominal
Voltage
Current Draw
on Alarm (mA)
121111101.12 2wire* No — 12/24 VDC 10 to 100
BIIORLP 2wire* Yes - 24 VDC 22 to 62
9II2LP 4-wire Yes Form-A & -C 24 VDC 14 to 39
BII4LP 4-wire Yes Form-A &
+ A Supervisory 120 VAC 75 mA AC
maximum
BII6LP 2wire* No Form-C 24 VDC 12 to 100')
B4O1 2-wire' I No - 12/24 VDC 10 to 100
SYSTEM
SENSOR
WFD Series
Waterfiow Detector
The System Sensor WFD series is compatible
with schedule 10 through 40 steel pipe, sizes
2 "through 8 and can be mounted in a vertical
or horizontal position.
Features
Two-inch mounting hole provided in new WFD30-2 models
UL-listed models are NEMA 4 rated
Sealed retard mechanism immune to dust and other contaminants
Visual switch activation
Field-replaceable retard mechanism and SPDT switches
Rugged, dual SPDT switches enclosed in a durable terminal block
Accommodates up to 12 AWG wire
Designed for both indoor and outdoor use
100 percent synchronization activates both alarm panel and
local bell
Tamper-resistant cover screws
Agency Listings
@ @ 0 MEA <~>
LISTED approved APPMED
5/39 (5169 7770.1653114 167-93-E 3006195
Robust Construction. The WFD series consists of a rugged,
NEMA 4-rated enclosure. Designed for both indoor and outdoor
use, the WFD series operates across a wide temperature range, from
32°F to 120°F
Reliable Performance. UL-listed models are equipped with
tamper-resistant cover screws to prevent unauthorized entry. Inside,
two sets of SPDT (Form C) synchronized switches are enclosed in a
durable terminal block to assure reliable performance.
False Alarm Immunity. The WFD series incorporates a mechanical
retard feature, which minimizes the risk of false alarm due to
pressure surges or air trapped in the sprinkler system. In addition,
the mechanical retard's unique sealed design is immune to dust and
other contaminants.
Simplified Operation. The WFD series is designed to simplify
installation. Two conduit openings permit easy attachment to the
local alarm system. The retard mechanism and dual SPDT switches
are field-replaceable.
Waterf low Detector
Vane-type waterfiow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any
clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6 from any fittings that may change water direction,
flow iate, or pipe diameter or no closer than 24 from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a
static pressure rating of 450 psiA for 2-- 8 pipes. The detector shall respond to waterfiow in the specified direction after a preset time delay that is field
adjustable.The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation.The actuation mechanism shall include
a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual
SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors.
A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by
Underwriters Laboratories Inc. for indoor or outdoor use.
Static Pressure Rating 450 PSI Operating Temperature Range 32AF to 1207 (ODC to 49DC)
Maximum Surge 18 Feet Per Second (FPS) Enclosure Rating* NEMA 4—suitable for indoor/outdoor use
Triggering Threshold 4-10 GPM Cover Tamper Switch Standard with ULC models, optional for UL
Bandwidth (Flow Rate) models, part no. 546-7000
Conduit Entrances Two openings for Wconduit. Service Use Automatic Sprinkler: NFPA-13
One open, one knock-out type One or Two Family Dwelling: NFPA 13D
Residential Occupancies up to 4 Stories: NFPA 13R
National Fire Alarm Code: NFPA-72
Contact Ratings Two sets of SPDT (Form C) U.S. Patent Numbers 5,213,205
10.0 A,½HP@ 125/250 VAC
2.5 A @ 6/12/24VDC
Compatible Pipe Steel water pipe, schedule 10 through 40 Warranty 3 Years
WFD Field Wirina Diaqram
NOTE: COMMON AND BAYS
UL.LISTED SSVI2o.X CONNECTIONS WELCLOSE
WHEN VANE IS DEFLECTED, LE.. COMPATIBLE CONTROL PARR. WHEN WATER IS FI.SWWGMUAJ. SWITCHES PERMIT POWEN 240CC ON
APPLICATIONS 10 BE COMBINED DNA SINGLE DETECTOR.
1200CC -
I CDNTACTRAI1NGS I
INITIATING. • SUGGESTED CCL lOMB'S I LOOP - RES TON I 04000 i 2.SAMPS I
SCHEMATIC OF AAAI INDPIIDUAL SWITCH IN YISWATORFLOW CONDITION iA___,,I
BREUXWIREAS SHOWN FOR SUPERVISION OF CON NECTION.DO NOT. STRIPPED WIRE I:} 1••;;I;;p
LEASSTO EXTEND
BEYOND SWITCH HOOD BID. DO NOT LOOP WIRES.
Delay Adjustment Dial
DELAY olAl. ID
WIOEE001ESUEE000BSCUDWN NUMBER ON DIAL I! U,PRUNMSTE YUlE DELAY U BEGOSOB WIIHMIACSUDAGY OF .1- DUN.
Overall Dimensions, Installed
1- 3.711 -----
IN
PIP. ."d].
L.-WIdlIoMATMI. '
OrderingIfl1ATiiTh4LA1,
UL Model ULC Model Pipe Size Hole Size Shipping Weight
WFD20 WFD20A 2 1W 4.2 lbs.
WFD25 WFD25A 21/2- 1144" 4.3 lbs.
WFD30-2 WFD30-2A 3 2 4.5 lbs.
WFD35 WFD35A 3W 1Y4 4.7 lbs.
WFD40 WFD40A 4 2 5.2 lbs.
WFDSO WFD50A 5 2 6.3 lbs.
WFD605 WFD60A 6 2 6.8 lbs.
WFDBO' WFDSOA 8 2 7.5 lbs.
Accessories
A3008-00 Retard mechanism
A77-01-02 Terminal block
546-7000 Tamper-proof switch kit
WFDW Tamper-proof wrench for cover
WFDN4 Gasket kit
'Maximum pressure rating 400 psi as approved by Factory Mutual.
$ SENSORY F" SYSTEM C2009SysIeroSensot
3825 Ohio Avenue• St. Charles, IL 60174
Phone: 800-SENSOR2 . Fax: 630-377-6495
PRLXO dSPFCSCASURSAUbJSCTTOCITAngeW1TIISUIISTKV.AA:TSYSTeIYDeRSOTCOnYIOI
A05.0180013. W-9,1922