HomeMy WebLinkAbout234 DATE AVE; ; AS070303City of Carlsbad Sprinkler Permit Permit No: A8070303 Job Address: 234 DATE AV Status: ISSUED Permit Type: SPRINK Applied 12/27/2007 Parcel No: 2060802500 Approved: 12/27/2007 Lot #: 0 Reference No.: Issued: 12/27/2007 PC #: Inspector: Project Title: CRESCENT DEL SQL ESTATES 3 FIRE SPRINKLER INSPECTIONS @$65/EA Applicant: VANGUARD FIRE PROTECTION 1604 LA MIRADA DR #105 SAN MARCOS CA 760-727-8540 Owner: .• LAGOON BREEZE DEVELOPMENT CORP 7237 SANDERLING CT CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($). 195 0 195 0 CRESCENT DEL SQL ESTATES Drawing Date:11-16-07 12/ 7/07 14:13 HYDRAULIC DESIGN INFORMATION SHEET Job Name: CRESCENT DEL SOL ESTATES Location: 234/236 DATE AVENUE CARLSBAD, CA Drawing Date: 11-16-07 Contractor: VANGUARD FIRE PROTECTION 925 POINSETTIA SUITE 11 VISTA, CA 92081 Designer: S.B. Calculated By: SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: S-3 Reviewing Authorities : CFD Remote Area Number: 1 Telephone :760-727-8540 APPROVED A1 BMITTED CARLOAD ENT Occupancy: SYSTEM DESIGN Code:NFPA 13 Hazard:ORD 1 System Type:WET Area of Sprinkler Oper. 911 sq ftl Sprinkler or Nozzle Density (gpm/sq ft) 0.150 I Make: TYCO Area per Sprinkler 113.0 sq ftl Model: TY-FRB Hose Allowance Inside 0 gpm I K-Factor: 5.60 Hose Allowance Outside 250 gpm I Temperature Rating: 200 CALCULATION SUMMARY 10 Flowing Outlets gpm Required: 437.5 psi Required: 79.2 @ Source WATER SUPPLY Water Flow Test I Pump Data I Date of Test 11-29-07 I Rated Capacity 0 gpm I Static Pressure 100.0 p5i I Rated Pressure 0.0 psi I Residual Pres 95.0 si I Elevation 0 At a Flow of 1405 gpm I Make: I Elevation 0" I Mol: I Location: SITE Source of Information: VANGUARD FLOW TEST SYSTEM VOLUME 236 Gallons Notes: These plaits have been reviewed for apparent cotiipllance with the current applicable codes and siandard in lbrce in the jurisdiction The owner or contractor iiia uiilii this ievless in uppot t of an application for a hit ildiii&i perunti with the express understanding that this res iew Ili no way relies en the owner or contractor or their proiensional enguteer or aivhiiect for sole responsihilits for full compliance with said codes and standards; including the building code or 11w any responsihilty for deficiencies. errom omissions or negligence in these plans whether or not noted in this review. Date: A00,7 Rcviewer) RECOMMEND APPROVAL 0 RECOMMEND APPROVAL. AS NOTED A60 CRESCENT DEL SQL ESTATES Drawing Date:11-16-07 12/ 7/07 14:13 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpni psi TOTALS Hydr Ref W Required at Hyd Area 1 188 68.5 psi 1 Pipe 2" DFx21 18' 120 2.703 188 1.5 4 2-1/2" Grvd 90 Eli 120 2.469 188 2.9 Hydr Ref BOR Required at BASE OF RISER 188 72.8 psi 1 Pipe 4" DIx18 Cl 350 20' 140 4.238 188 0.1 4 4" Flngd 90 Eli 40' 120 4.026 188 0.5 1 4" Flngd Back Flow Valve FEBCO "876 CHART LOSS 188 5.3 1 Pipe 4" DIx18 Cl 350 140 4.238 188 0.2 1 4" Flngd Gate Valve 11722tJ" 2' 120 4.026 188 0.0 1 4" •Flngd Tee 20' 120 4.026 188 0.2 Fixed Flow Flow Loss 250 gpm Hydr Ref SC Required at Source 438 79.2 psi Water Source100.0 psi static, 95.0 psi residual @ 1405 gpm 438 gpm 99.4 psi SAFETY PRESSURE 20.2 psi Available Pressure of 99.4 psi Exceeds Required Pressure of 79.2 psi This is a safety margin of 20.2 psi or 20 % of Supply Maximum Water Velocity is 16.5 fps CRESCENT DEL SOL ESTATES Drawing Date:11-16-07 12/ 7/07 14:13 Page 3 FITTING NAME TABLE ABBREV. NAME C - Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x -\/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf/ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)'l.85 / ID"4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q"2/ID"4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations CRESCENT DEL SQL ESTATES Drawing Date:11-16-07 12/ 7/07 14:13 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K-FACTOR FLOW FLOW DENSITY (FT) (GPM/(PSI-&i)) (PSI) _____________ (GPM) (GPM) (GPM/SQ.FT) 1 10.17 5.60 10.0 p 17.7 u.rriup -• cr.rr.- 17.0 - in- 0.16 2 10.17 5.60 9.2 16.9 17.0 0.15 3 10.17 5.60 10.4 18.0 17.0 0.16 4 10.17 5.60 11.7 19.2 17.0 0.17 5 10.17 5.60 14.1 21.1 17.0 0.19 6 10.17 5.60 9.9 17.6 17.0 0.16 7 10.17 5.60 10.1 17.8 17.0 0.16 8 10.17 5.60 10.7 18.3 17.0 0.16 9 10.17 5.60 12.1 19.5 17.0 0.17 10 10.17 5.60 14.6 21.4 17.0 0.19 20 10.17 10.1 Al 10.17 18.0 A2 10.17 18.6 Bi 10.17 63.1 W 10.17 68.5 Max velocity of 16.54 occurs in the pipe from A2 TO 10 L CRESCENT DEL SOL ESTATES Drawing Date:11-16-07 12/ 7/07 14:13 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 2 TO W (PRIMARY PATH) 16.95 1.080 iT 6.09 9.2 9.2 K = 5.60 2 C=120 5.76 0.0 0.0 16.95 0.083 11.85 1.0 9.2 Vel = 5.99 17.73 1.536 3.71 10.1 10.1 20 C=120 0.00 0.0 0.0 See PATH 3 34.68 0.056 3.71 0.2 10.1 Vel = 6.06 18.02 1.536 11.20 10.4 10.4 K = 5.60 3 C=120 0.00 0.0 0.0 52.70 0.122 11.20 1.4 10.4 Vel = 9.21 19.17 1.536 11.20 11.7 11.7 K = 5.60 4 C=120 0.00 0.0 0.0 71.87 0.217 11.20 2.4 11.7 Vel = 12.57 21.06 1.536 iT 1.00 14.1 14.1 K = 5.60 5 C=120 10.11 0.0 0.0 92.94 0.348 11.11 3.9 14.1 Vel = 16.25 2.203 10.12 18.0 18.0 Al C=120 0.00 0.0 0.0 92.94 0.060 10.12 0.6 18.0 Vel = 7.90 94.59 2.203 5E 137.53 18.6 18.6 A2 C=120 2T 64.10 0.0 0.0 See PATH 2 187.53 0.220 iF 201.63 44.5 18.6 Vel = 15.94 2.703 1E 57.43 63.1 63.1 Bi C=120 9.33 0.0 0.0 187.53 0.081 66.76 5.4 63.1 Vel = 10.59 W 187.53 68.5 K = 22.66 PATH 2 FROM HYDRAULIC REFERENCE 6 TO A2 17.60 1.536 11.20 9.9 9.9 K = 5.60 6 C=120 0.00 0.0 0.0 17.60 0.016 11.20 0.2 9.9 Vel = 3.08 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) CRESCENT DEL SQL ESTATES Drawing Date:11-16-07 12/ 7/07 14:13 Tyco Fire Products Page 6 1-IYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv NOTES ******* POINT Qt Pf/ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 6 TO A2 CONTINUED 17.76 1.536 11.20 10.1 10.1 K = 5.60 7 C=120 0.00 0.0 0.0 35.35 0.058 11.20 0.7 10.1 Vel = 6.18 18.32 1.536 11.20 10.7 10.7 K = 5.60 8 C=120 0.00 0.0 0.0 53.68 0.126 11.20 1.4 10.7 Vel = 9.39 19.50 1.536 11.20 12.1 12.1 K = 5.60 9 C=120 0.00 0.0 0.0 73.17 0.224 11.20 2.5 12.1 Vel = 12.79 21.42 1.536 iT 1.00 14.6 14.6 K = 5.60 10 C=120 10.11 0.0 0.0 94.59 0.360 11.11 4.0 14.6 Vel = 16.54 A2 94.59 18.6 K = 21.92 PATH 3 FROM HYDRAULIC REFERENCE 1 TO 20 17.73 1.536 7.49 .10.0 10.0 K = 5.60 1 C=120 0.00 0.0 0.0 17.73 0.016 7.49 0.1 10.0 Vel = 3.10 20 17.73 10.1 K = 5.57 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance CRESCENT DEL SOL ESTATES Static Pressure: 100.0 psi Pressure: 79.2 psi Inside: 0 gpm 234/236 DATE AVENUE Residual Pressure: 95.0 psi System Flow: 188 gpm Outside: 250 gpm CARLSBAD, CA Flow: 1405 gpm System+Hose: 438 gpm Remote Area: I Date: 11-29-07 Safety Pres: 20.2 psi Loc: SITE Head Elev Pres: 68.5 psi 140-- I I I I I I I I 120 - 1001 Su P 80 hose S I 68.5 60 - 40 - 20 100 150 200 250 300 350 400 450 500 Flow (anm tqCC /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-FRB - Upright, Pendent, Quick Response, General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TV-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in afire situation or cause if to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The-owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 1l2"NPT TV1231 - Pendent 2.8K, 1I2"NPT TY2131 - Upright 4.2K, 112"NPT TY2231 - Pendent 4.2K, 1I2"NPT TY3131 - Upright 5.6K, 1!2"NPT TY3231 - Pendent 5.6K, 1l2"NPT TY4131 - Upright 8.0K, 3I4"NPT TY4231 - Pendent 8.0K, 314"NPT TY4831- Upright 8.0K, 112"NPT TY4931- Pendent-8.0K, 1I2"NPT 28,4.2,5.6, and 8.0 K-factor and Recessed Pendent Sprinklers Standard Coverage Page 20f 10 TFPI7I ESCUTCHEON PLATE SEATING SURFACE I \2-1/4" (57,2 mm) 1-9/16" (39,7 mm) SSP DEFLECTOR * 2-7/8"(73,0 mm) DIA. SSU* DEFLECTOR iL 7/16" 1 (11,1 mm) I NOMINAL I MAKE-IN I 2-3/16" WRENCH t (55,6 mm) FLATS 1/2"NPT 7/16"(11,1 mm) STYLE 10or20 NOMINAL RECESSED NPT MAKE-IN ESCUTCHEON PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5-Compression 7-Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT ESCUTCHEON 7/116"(1111,11 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE 1/2" MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR 2-3116" (N( mm) (55,6 mm) -* NAL _______ " 6* 1-1/2" III ii il/ -IN 2 3/ WRENCH ____ FLATS (55,6mm)(38,1mm) I SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. -""I 1/2" NPT t PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFPI7I Page 3of 10 ESCUTCHEON 7/16"(11.1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED * SURFACE NPT MAKE-IN ESCUTCHEON SSU DEFLECTOR (55,6 mm) J NOMINAL FLATS 3 * SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw FIGURE 3 - QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT STYLE 30 or 40 RECESSED ssu ESCUTCHEON DEFLECTOR 6* ESCUTCHEON 1/2"(12,7 mm) PLATE SEATING NOMINAL SURFACE MAKE-IN NPT *-T 2_J16" (58,7 mm) 1-9/16" (39,7 mm) WRENCH FLATS SSP DEFLECTOR * l 2-7/8"(73,0 mm) D. 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT 1/2" (12,7 mm) NOMINAL MAKE-IN I 2-1/4" (57,2 mm) 5 il r CROSS SECTION I - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES 7Y-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3M INCH NPT 7/16"(11,1 mm) NOMINAL SSU MAKE-IN DEFLECTOR 1/2" NPT 2 (57, sSP* DEFLECTOR PENDENT UPRIGHT CROSS SECTION Page 40110 TFPI7I - Frame 3-Sealing 4- Bulb 6- Deflector * Temperature rating is Indicated on deflector or adjacent to 2- Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS LO K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approve( information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psill2 (40,3 LPM/barl'2) K = 4.2 GPM/psi112 (60,5 LPM/bar1'2) K = 5.6 GPM/psi112 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPMIbarl12) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. 4.- TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED I WHITE'"" JPOLYESTER 2.8 1/2" PENDENT (TY1231) and UPRIGHT (TYII3I) 135°F157°C Orange 1,2,3,5 155°F/680C Red 175°F179°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT 135°F/57°C Orange 1,2,5 RECESSED PENDENT (rv1231)' Figure 6 155°17/680C Red 175°F/79°C Yellow 200°F/93°C Green 135°F157°C Orange RECESSED (rY1231)"" Figure 7 PENDENT 155'F168"C Red 175°F179°C Yellow 200°F193"C Green 4.2 1/2' NPT PENDENT (M231) and UPRIGHT (TY2131) 135°F/57°C Orange 1,2 155°F/680C Red 1756F1790C Yellow 200°F/93"C Green 286"F/141°C Blue 135°F157°C Orange RECESSED PENDENT (TY2231)* Figure 8 155"F/68°C Red 1750F/790C Yellow 200°F/93°C Green 135°F157°C Orange RECESSED PENDENT (Y2231 Figure 9 1556F/680C Red 175"F/79'C Yellow 200°F193°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use In Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10(112" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 5 of 10 Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. I BULB LIQUID NATURAL BRASS VCHROME PLATED WHffE POLYESTER I LEAD COATED - 5.6 1/2" PENDENT and UPRIGHT M131) 135°F/57°C Orange "M31)1,2,3"M31)1,2,3,4,5,6,7 1550F/680C Red 175°F179°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT 1350F157°C Orange 1,2,4,5 N/A RECESSED PENDENT (Y3231)* Figure 10 1550171680C Red 175°F/79°C Yellow 193°C E Green /57"C Orange 1, 2, 3,4,5 N/A RECESSED PENDENT (TY3231) Figure 11 155°F/68°C Red 175°F/79"C Yellow 200"F/93°C Green - 8.0 3,4" PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1,2, 3,4,5, 6,7 1,2,5 155°F/68°C Red 175017/790C Yellow 200017/93"C Green 286°F/141°C Blue NPT 135°F/57°C Green 1,2,4,5 N/A RECESSED PENDENT (TY4231)* Figure 12 155"F/68'C Orange 175°F179°C Red 2000171930C Yellow 135017/570C Orange 1,2,3,4,5 N/A RECESSED PENDENT (rv4231)- Figure 13 155617/680C Red 175°17/796C Yellow 200°F/93°C Green - 8.0 1/2" NPT PENDENT (T'V'4931) and UPRIGHT (TY4831) ff 1350F/570C Orange 1, 2,4,5, 6 1, 2, 5 155°F/68°C Red 1750F1790C Yellow 200"F/93°C Green 286'F/141-Cl Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k104) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA354-01-E. VdS Approved (For details contact Tyco Mre & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * installed with Style 10(1/2" NPT) or Style 40(314" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** installed with Style 20 (1/2" NP or Style 30 (314" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12.1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (1Y4131) 175 PSI (12.1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12.1 BAR) 5.6 UPRIGHT (TY3131) OR 10 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE NIA PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12.1 BAR) 8.0 UPRIGHT (TY4131) RECESSED PENDENT NPT (1Y4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (1Y4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 inch (2,4 mm) for the 286°F/14 1°C temperature ratings. A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tamed with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series 1Y-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be Installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler Into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 - 2-7/8" DIA. 5/8±1/4" (73.0 mm) I 3/4"(19,11 mm) - (15,90,4 mm) - 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF (57 2 mm) -;::;i I MOUNTING I SPRINKLER / PLATE I FITTING 1/8" MOUNTING CLOSURE SERIES 11-5/116"(33.1 mm)1 SURFACE//' TY-FRB 13116"(20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 34"(194 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (572 MOUNTING SPRINKLER 7J1 PLATE FITTING iLiJ 4 MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(119,11 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I 2-7/8" DIA. (73,0mm) 1/2±1/8" I 1/2"(12,7 mm) r (12,70.2 mm) 2-1/4" DIA. I 114" (6.4 mm) I I FACE OF PLATE I SPRINKLER (57.2 mm) MOUNTING I FITTING / ____ (3,2mm) j/;- 1/8" I MOUNTING f t SURFACE CLOSURE SERIES 1-5/16" (33.3 mm)f TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-718* DIA. - 1/2±1/8" (73,0 mm) I 1/2" (12,7 mm) 1 (12,7±3.2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I I FACE OF (57,2 mm) I MOUNTING I I SPRINKLER I I PLATE I FITTING 01/ 4 T \ MOUNTING SURFACE CLOSURE SERIES I- 1/4" (31 8mm) TYFRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from The proper authorities and all personnel who maybe affected by this action must be notified. The owner must assure that The sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- TFPI7I 2-7/8" DIA. • 5/8±1/4" (73,0 mm) I 3/4'(19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. I 1/4" (6,4 mm) I I FACE OF 57,2 MOUNTING SPRINKLER PLATE FITTING 1/8" Au MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TV-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - 5/8±1/4" (73,0 mm) 3/4.(19.1 mm) - (15,9±8,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF I (57,2 mm) TJ MOUNTING SPRINKLER 'c - PLATE FITTING (3,2 mm) _____ _____ MOUNTING SURFACE I . 4 CLOSURE SERIES 1-5/16"f33 mm) TYFRB 13/16"(20.6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT Page 9 011''10 - 2-7/8" DIA (73.0 mm) I 1/2±1/8" j 1/2" (12,7 mm) r (12,70.2 mm) 2-1/4" DIA. I 1/4"(6,4 mm) I I SPRINKLER I PLATE I FACE OF 157.2 mm) MOUNTING I FITTING 1/8" t \ MOUNTING SURFACE 7W1 SERIES 1-1/4' (31,8 mm) CLOSURE 1YFRB 1"(25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7I8 DIA. (73,0 mm) I 1/2"(12,7mm) (12.7±3,2 mm) f 24/4" DIA. I 1/4" (6,4 mm) I FACE OF MOUNTING SPRINKLER FITTING (57,2mm) PLATE 13 2 I 'I t \ — MOUNTING SURFACE CLOSURE SERIES 1-&16"(33,3 mm) TY-FRB 1-1/16"(27.0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHINGAREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Page 10 of 10 TFPI7I PIN 57-XXX-X--XXX I MODELJSIN I 1 I 4 3 9 7 TY4131 SPRINKLER NATURAL BRASS WHITE POLYESTER WHITE (RAL95IO)* CHROME PLATED LEAD COATED I RATING ..L... 135 1356171570C 155 155F/68°C 175 175Ffl9eC 200 2000F193°C 286 286°F11418C * Eastern Hemisphere sales only. 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (112"NPT) TY1231 340 4.2K UPRIGHT (112"NPT) 1Y2131 341 4.2K PENDENT (112"NPT) TY2231 370 5.6K UPRIGHT (112"NPT) TY3131 371 5.6K PENDENT (112"NPT) TY3231 390 8.0K UPRIGHT (314"NPT) 391 8.0K PENDENT (3/4 N PT) TY4231 360 8.0K UPRIGHT (1/2*NPT) TY4831* 361 8.01< PENDENT (10NPT) 1Y4931* TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper Installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN) Quick Response, (specify K-factor), (specify temperature rating), Series TV-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin-ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. MODEL 876V DOUBLE CHECK DETECTOR ASSEMBLY (Shown in vertical orientation) U.S. Patent No. 4,989,635 • U.S. Patent No. 5,107,888 U.S. Patent No. 5,385,166 • U.S. Patent No. 5,226,441 U.S. Patent No. 5,392,803 • U.S. Patent No. 5,503,176 MODEL 876V DOUBLE CHECK DETECTOR ASSEMBLY (Shown in standard orientation) ES-F-876V MasterSeries® 876V Double Check Detector Assemblies Size: 2½" - 10" (65mm - 250mm) The FEBCO MasterSeriesO 876V Double Check Detector Assemblies are designed for use in non-health hazard fire sprinkler systems. Standard orientation is inlet flow vertical up, outlet flow vertical down. Vertical orientation is inlet and outlet flow vertical up. Materials Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AWtAJA C550-90 Shutoff Valves: OS&Y resilient wedge gate valves AWWA C509 Trim: Bronze Elastomer Discs: EPDM Spring: Stainless steel Models Valve Setter with MJ x MJ, MJ x FL or FL x FL ends End Connections - Flanged ANSI B16.1 Class 125 Pressure - Temperature Maximum Working Pressure: 175psi (12.1 bar) Hydrostatic Test Press: 350psi (24.1 bar) Temperature Range: 32°F to 140°F (0°C to 60°C) Approvals - Standards ANSI/A\MNA (C510) Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. ® * Approved C®US 1048 864.5 * Less gate not FM approved. Less gate not UL Classified unless installed with UL Listed gate valves Job Name Contractor Job Location Approval Engineer Contractor's RO. No. Approval Representative FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise mea- Model 876V / Materials of Construction U DESCRIPTION MATERIAL U DESCRIPTION MATERIAL # DESCRIPTION MATERIAL 1 Body A536 GR 65.4502 8 Lower Sprg. Retainer B584 Alloy C836O0 350-ring EPDM ASTM D1999 2 Cover A536 GR 6545-12 Spring Stem 304SS 35.1 Back UpRing Acetal Resin 2.1 0-ring EPDMASTMD2000 9.1 Elastic Stop Jam Nut 188SS 36 Cover B584AllC83600 2.2 Cap Screw Plated Steel 10 Spnng A31131ype 631 SS 40 BailVake 8584 Alloy C83600 23 Hex Nut Plated Steel 102 Spring Shim Acetal Resin 41 Nipple Brass 2.5 Cover (wibholes) A536 GR 6545-12 103 Spring Shim Acetal Resin 42 GateVave(0S&) AWrNAC509 3 Seat Ring 8524Alloy C83600 11 Spring Guide B130AflrC22000 43 Bulkhead Frtting B584Aff,C83600 31 Gasket EPDMASTMD2000 12 Upper Sprg. Retainer B584AlloyC83600 43.1 Bulkhead Fitting B584 Alloy C83600 4 Arm B584Albt, C83600 12.1 Bushing Sprg. Stem Acetal Resin 44 Bulkhead Fitting B584ftJ1oy C83600 4.1 Bushing-Swing Pin Metal Resin 13 Pivot Bearing B5B5 Alloy C83600 45 Gasket EPDMASTM D2000 4.2 Swing Pin 304S5 14 Flange Gasket Rubber/Fabric 45.1 Gasket EPDMASTMD2001 5 Retaining Clip 3025S 15 Bearing Socket AcetaiResin 46 Washer B36 Alloy 260 5.1 Retaining Clip 30255 16 Hex Jam Nut 188SS 46.1 Washer B36 Alloy 260 6 Check Disk (2W-81 EPDM Coated GR, 45 Capscrew(1(1) 188SS 47 Nut 8584AlloyC83601 Ductile Iron w/type 17 Washer 302S5 471 Nut B584 Alloy C63602 3045S 18 Flange Nut PlatedSteel 60 Identification Plate B36 Alloy C26000 Seat Disc MY) Silicone ASTMD2000 18.1 Range Nut Plated Steel 61 Identification Plate B36ftJkC26000 6.1* Disc Holder (101 ASIM A743 304 ss 19 Cover 436 Stt Epoxy Coated 62 Drive Screw Stainless Steel 6.2* Disc Retainer (10) ASTM A43 304 SS 24 Bolt Plated Steel 70 Clamp 8?BV Only AWNAC6O6 6.3 Capsorew iioi ss 24.1 Washer Plated Steel 7 1 .I 25 Nut Plated Steel Model 876V Model 876V Standard Orientation Vertical Orientation Note: The Series 876V is shipped in the standard (N-Shape) orientation as shown above. OS&Y Side V Dimensions - Weights Size: 21/a" - 10" (65 - 250mm) SIZE(DN) DIMENSIONS WEIGHT EL - A in. I mm B in. I mm C in. I mm El OS&Y in. I mm F in. mm G in. I mm H I in. I mm J in. I mm K in. I mm M in. I mm OS&Y tbs. kgs. 2½ 65 12% 318 25/4 654 241A 616 16% 416 16% 422 61/4 159 111h 292 3½ 89 13% 346 271/4 692 230 104 3 80 12½ 318 253/4 654 24/4 629 22¼ 565 16% 422 6¼ 159 11½ 292 3~ 95 141A 359 281/4 718 300 136 4 100 14 356 27% 708 26~ 680 23'/4 591 13 330 4½ 114 15½ 394 31 787 330 150 6 150 16 406 32¼ 819 32¼ 819 30', 765 21,4 203 13 330 5½ 140 18% 473 37¼ 946 520 236 8 200 18½ 470 37½ 953 36% 924 37% 959 17/4C4517178 24% 235 14½ 368 6% 172 20% 527 41½ 1054 860 390 10 250 21 533 42½ 1080 40~ 1035 48 1219 27½254 1 15 381 8 203 24 610 48 1219 1460 662 'OS&Y OPEN Weights do not include risers or optional valve seller. Note: Dimensions shown are nominal. Allowances must be made for normal manufacturing tolerances. Flow 9 C min ? Flow ir mm r mm mm 0mm) _____________ i - All 11 "1 -.1 97 14 83 12 69 10 41 6 284 14 2 00 IcPa psi 110 16 97 14 83 12 69 10 D550 41 6 204 14 2 00 0 msi 1mm imm 4553 1355 $J gpm 1960 3880 5600 7560 3480 11350Ipm r(200mm) TvDical Installation Standard orientation (Series 816V) Verticaf orientation (Series 876V) 18°min (450mm) ir mm IIh.n.% I (100mm) _______ - "- Pipe Support -01~ IF (100mm °r valve weight only. NAM *Aft 4fl min (furnished by customer) Optional Valve Recommended Seter minimum clearances from permanent structures for ease of testing and maintenance are shown on above drawings. Capacity kPa pi 2t1f(65mm) kPa pd 61150mm) 110 97 0093 69 55 41 28 14 W lixi iu zmi ax axgpm 190 380 570 760 950 1140 km kPa psi 4 (100mm) 124 It - - - - - - - 110 it — 97 I - 41 ' - 83 it —A 69 W -- = 56 8 — — — — 28 4 142_— I 4 - 0 380 160 1140 1520 1902 2200 2660 A-Vertical orientation B-Standard orientation 110 16 97 14 83 12 69 10 55 = 41 8 284 14 2 00 ir (250mm) B 0 1060 2800 2450 4080 6000gpm 0 3860 7560 11350 15140 18000 1pm The 6 and 10 flow curves (B-standard orientation) include the FEBCO Valve Setter Series 611. A Division of Watts Water Technologies, Inc. USA: 4381 N. Brawley • Ste. 102 • Fresno, CA • 93722 • Tel. (559) 441-5300 • Fax: (559) 441-5301 • www.FE8C0online.com Canada: 5435 North ServIce Rd. • Burlington, ONT. • 1-71- 51-17 9 Tel. (905) 332-4090 • Fax: (905) 332-7068 9 www.FEBC0online.ca Tol-Brace Seismic Calculations Project CRESCENT DEL SOL it VANGUARD FIRE PROTECrlON Address. . 925 POINSETTIA AVE SUITE'?I . .• 234/236 DATE .... VISTA, .1 •';..'I.'.;.. V , I 487475 CARLSBAD, CA 760-727-8540 Job # Calculations based on 2002 NFPA Pamphlet #13 with TIA 02-1 Brace Information Tolco Brace Components Tolco Component Fig. Number Adjusted Load Maximum Spacing 10'-0" (3.08m) Fig. 1000 Clamp 567 lbs. (257 Kg.) Length of Brace 7 '- 0 "(2.2m) Fig. 980 Universal Swivel 2395 lbs. (1086 Kg.) Bracing Material 1" Sch.40 *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for Tolco components only. A Angle from Vertical W Ifl. Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11mm) Assembly Detail LIR Value 200 Maximum Horizontal Load 3061 lbs. (1388Kg.) VNI'VERS'AL $'-WAY BRACE FITflNG TC•LC: FIG. 1000 FAST CLAMP- -.. Fastener Information STEEL PIPE _. . Fastener Orientation NFPA Type C LATERAL 4? BR-ACE Type Wedge Anchor Diameter 3/8in. (10mm) 600 Mm. From vertical Length 3m. (76mm) Brace Identification on Plans A Maximum Load 615 lbs. (279Kg.) Orientation of Brace Lateral Load Information Size and Type of Pipe Total Length Total Calculated Load 2W(63mm) Schedule 7 Pipe 10 ft. (3m) 26 lbs. (12Kg.) Percentage added for Fittings and Sprinklers 15% 4 lbs. (1.74Kg.) Total Adjusted Load of all pipe within Zone of Influence 29 lbs.(14Kg.) (Tol-Brace Version 5.1.67) Tol-Brace Seismic Calculations For CRESCENT DEL SQL 234/236 DATE Job # Brace Identification Brace Type (Per NFPA#13) Spacing of Brace Orientation of Brace Bracing Material Length of Brace Slenderness Ratio used for Load Calculation True Angle of Brace for Calculation Type of Fastener Length of Fastener A NFPA Type C 10 Ft.(3m) Lateral 1" Sch.40 7Ft. (2m) 200 60° 318in. (10mm) In. Wedge Anchor 3m. (76mm) In. Summary of Pipe within Zone of Influence 2% inch Sch. 7 10 Feet (3m) Allowance for Heads and Fittings 0.15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 29 Ibs.(13Kg.) Material Capacity 3060.5991574859 lbs.(1388Kg.) Fastener Capacity 615 lbs.(279Kg.) Fig. 1000 Clamp 567 Ibs.(257K9.) Fig.980 Universal Swivel 2395 Ibs.(1086Kg.) Structural Member: CONC DECK* Calculations prepared by SB *The description of the Structural Member is for informational purposes only. Toi.Brace software calculates the brace assembly only, not the structure it is attached to. Calculated with 101-Brace 5.1 vtsft us atvus.tolco.com Tol-Brace Seismic Calculations Project CRESCENT DEL SOL Address. VANGUARD FIRE PROTECTION 925 POINSETTIA AVE SUITE ti •. ... 234/236 DATE VISTA, CA 92081 ?.I 487475 CARLSBAD, CA 760-727-8540 Job # Calculations based on 2002 NFPA Pamphlet #13 with TIA 02-1 Brace Information Tolco Brace Components Tolco Component Fig. Number Adjusted Load Maximum Spacing 1O'-O" (3.O 8m) Fig.4 Clamp 342 lbs. (155 Kg.) Length of Brace 7 - 0 "(2.2m) Fig. 980 Universal Swivel 2395 lbs. (1086 Kg.) Bracing Material 1" Sch.40 *Calculation Based on CONCENTRIC Loading *Please Note: These calculations are for Tolco components only. ng.e from Angle I Vertical . 60° Mm Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11mm) Assembly Detail LiR Value 200 TOLCO FIG. 'sc' Maximum Horizontal Load 3061 lbs. (1388Kg.) UNIVERSAL SWAY .. BRACE FITTING TYP. STEEL FIFE LATERAL -- • /' BRACE - Fastener Information TOLCO FIG. 4.4 FIFE CLAMP FOR SWAY BRACING Fastener Orientation NFPA Type C Type Wedge Anchor Diameter 3/81n. (10mm) 600 Mm. From Vertical Detail 01241 Length 3m. (76mm) Brace Identification on Plans B Maximum Load 615 lbs. (279Kg.) Orientation of Brace Longitudinal Load Information Size and Type of Pipe Total Length Total Calculated Load 2Y2"(63mm) Schedule 7 Pipe 10 ft. (3m) 26 lbs. (12Kg.) Percentage added for Fittings and Sprinklers 15% 4 lbs. (1.74Kg.) Total Adjusted Load of all pipe within Zone of Influence 29 lbs.(14Kg.) (Tol-Brace Version 5. 1.67) Tol-Brace Seismic Calculations For CRESCENT DEL SQL 234/236 DATE Job # Brace Identification Brace Type (Per NFPA#13) Spacing of Brace Orientation of Brace Bracing Material Length of Brace Slenderness Ratio used for Load Calculation True Angle of Brace for Calculation Type of Fastener Length of Fastener B NFPA Type C 10 Ft.(3m) Longitudinal Sch.40 7Ft. (2m) 200 60° 3181n. (10mm) In. Wedge Anchor 3m. (76mm) In. Summary of Pipe within Zone of Influence 2% inch Sch. 7 10 Feet (3m) Allowance for Heads and Fittings 0.15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 29 lbs.(13Kg.) Material Capacity 3060.5991574859 Ibs.(1388Kg.) Fastener Capacity . 615 Ibs.(279Kg.) Fig.4 Clamp 342 lbs.(155Kg.) Fig.980 Universal Swivel 2395 lbs.(1086Kg.) Structural Member: CONC DECK* Calculations prepared by SB The description of the Structural Member Is for informational purposes only. Tol-Brace software calculates the brace assembly only, not the structure it is attached to. Calculated with Tot-Brace 5.1 vtslt us at wvm.tot.cOm Tol-Brace Seismic Calculations Project CRESCENT DEL SOL Address. ....................... VANGUARD FIRE PROTECTION 925 POINSETTIA AVE SUITEII •..,.......,.......' 234/236 DATE VISTA, CA 92081 ..........•. 487475 CARLSBAD, CA 760-727-8540 Job # Calculations based on 2002 NFPA Pamphlet #13 with hA 02-1 Brace Information Tolco Brace Components Tolco Component Fig. Number Adjusted Load Maximum Spacing 80'-0" (24.64m) Fig.4 Clamp 342 lbs. (155 Kg.) Length of Brace 7'- 0 "(2.2m) Fig. 980 Universal Swivel 2395 lbs. (1086 Kg.) Bracing Material 1" Sch.40 *Calculation Based on CONCENTRIC Loading *please Note: These calculations are for Tolco components only. A Angle from Vertical RO O Use of any other components voids these calculations and the listing of the assembly. Least Rad. of Gyration 0.42" (11mm) Assembly Detail LIR Value 200 TOLCO FIG. 80 Maximum Horizontal Load 3061 lbs. (1388Kg.) UNIVERSAL SWAY - BRACE FITTING TYP. STEEL PIPE LATERAL - BRACE Fastener Information TOLCO FIG. 4A PIPE CLAMP FOR Fastener Orientation NFPA Type C SWAY BRACING Type Wedge Anchor . ) Diameter 3/81n. (10mm) 60 Mm. From Vertical Length 3m. (76mm) Brace Identification on Plans D Maximum Load 615 lbs. (279K0.) Orientation of Brace Longitudinal Load Information Size and Type of Pipe Total Length Total Calculated Load 2W(63mm) Schedule 7 Pipe 80 ft. (24.4m) . 204 lbs. (93Kg.) Percentage added for Fittings and Sprinklers 15% 31 lbs.(13.88Kg.) Total Adjusted Load of all pipe within Zone of Influence 235 Ibs.(107Kg.) (ToI.Brace Version 5.1.671 Tol-Brace Seismic Calculations For CRESCENT DEL SOL 234/236 DATE Job # £. UI e- Brace Identification Brace Type (Per NFPA#13) Spacing of Brace Orientation of Brace Bracing Material Length of Brace Slenderness Ratio used for Load Calculation True Angle of Brace for Calculation Type of Fastener Length of Fastener 0 NFPA Type C 80 Ft.(24m) Longitudinal 1" Sch.40 7Ft. (2m) 200 600 3/8in. (10mm) In. Wedge Anchor 3m. (76mm) In. Summary of Pipe within Zone of Influence 21,4 inch Sch. 7 80 Feet (24m) Allowance for Heads and Fittings 0.15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 235 Ibs.(107Kg.) Material Capacity 3060.5991574859 lbs.(1388Kg.) Fastener Capacity 615 lbs.(279Kg.) Fig.4 Clamp 342 Ibs.(155Kg.) Fig.980 Universal Swivel 2395 lbs. (1 086Kg.) Structural Member: CONG DECK* Calculations prepared by SB *The description of the Structural Member is for informational purposes only. Tot-Brace softare calculates the brace assembly only, not the structure it is attached to. Calculated with Tot-Brace 5.1 visit us at .tolco.com