Loading...
HomeMy WebLinkAbout6339 DI VITA DR; ; AS05004210/8/2020 AS050042 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS050042 Job .Address: 6339 DI VITA DR Status: ISSUED Permit Type: SPRINK Applied 3/15/2005 Parcel No: 2131610400 Approved: 4/1/2005 Lot #: 0 Reference No.: Issued: 4/1/2005 PC #: Inspector: Project Title: LOT 288, BRESSI RANCH PA9 FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: WESTERN STATES FIRE PROTECTION GREYSTONE HOMES INC Balance ($) 0 1/1 WESTERN STATES FIRE PROTECTION 9550 CHESAPEAKE DR. SUITE201 SAN DIEGO, CA. 92123 HYDRAULIC CALCULATIONS - FOR I. BRESSI RANCH ?-9 PLAN TYPE 1 "FILE NUMBER: BRESSI9TYP1.sdf "DATE: 12-6-04 -DESIGN DATA- OCCUPANCY CLASSIFICATION: Residential DENSITY: 0.05 GPM PER SQUARE FOOT AREA OF APPLICATION: 2 HYDRALICALLY MOST REMOTE SPRINKLER S COVERAGE PER SPRINKLER: 18' X 18' NUMBER OF SPRINKLERS CALCULATED: 2 TOTAL SPRINKLER WATER FLOW REQUIRED: 370 GPM TOTAL WATER REQUIRED (including hose): 42.0 GPM FLOW AND PRESSURE (@ SOURCE): 42.0 GPM @ 77.6 PSI SPRINKLER ORIFICE SIZE: 1/2" 4.9 K FACTOR CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 5004004430) MRS SYSTEMS, INC. TUCKER, GA 30084 Asob~co I,&- / Asdc04(, Aacs4 /\SOSOOl CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions In correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit -It, aviolatnn of any law. DATE: 3/14/2005 JOB TITLE: WATER SUPPLY DATA SOURCE STATIC NODE PRESS. TAG (PSI) SOURCE 111.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 C:\HASS76\BRESS19TYPl.SDF RESID. FLOW AVAIL. TOTAL REQ'D PRESS. @ PRESS. 0 DEMAND PRESS. (PSI) (GPM) (PSI) (GPM) (PSI) 110.0 50.0 110.3 42.0 77.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 42.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 5.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 37.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 9.6 K= 4.90 13.5 18.0 2 9.6 K=,4.90 14.9 18.9 TOR 9.6 - - - - 37.8 - - - U 3.5 - - - - 47.8 - - - A -3.0 - * - - 53.2 - - - Ml 0.0 - - - - 64.6 M2 0.0 - - - - 69.6 - - - SOURCE -3.0 SOURCE 77.6 37.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/14/2005 C:\HASS76\BRESSI9TYP1.SDF JOB TITLE: PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -18.0 1.101 PL 12.30 PF 1.4 1 9.6 4.9 13.5 18.0 6.1 150 FTG ET PE 0.0 2 9.6 4.9 14.9 18.9 0.056 TL 25.69 PV Pipe: 2 -36.9 1.101 PL 85.00 PF 22.9 2 9.6 4.9 14.9 18.9 12.4 150 FTG E2T FE 0.0 TOR 9.6 0.0 37.8 0.0 0.212 TL 107.95 PV Pipe: 3 -36.9 1.101 PL 6.08 PF 7.4 TOR 9.6 0.0 37.8 0.0 12.4 150 FTG TA FE 2.6 U 3.5 0.0 47.8 0.0 0.212 TL 34.77 PV Pipe: 4 -36.9 1.245 PL 10.00 ?F 2.6 U 3.5 0.0 47.8 0.0 9.7 150 FTG 4EG PE 2.8 A -3.0 0.0 53.2 0.0 0.116 TL 22.50 PV Pipe: 5 -36.9 1.245 PL 100.00 PF 12.7 A -3,0 0.0 53.2 0.0 9.7 150 FTG 3E PE -1.3 Ml 0.0 0.0 64.6 0.0 0.116 TL 109.00 PV Pipe: 6 FIXED PRESSURE LOSS DEVICE M2 0.0 0.0 69.6 0.0 5.0 psi, 36.9 gpm Ml 0.0 0.0 64.6 0.0 Pipe: 7 -37.0 1.245 FL 45.00 PF 6.7 M2 0.0 0.0 69.6 0.0 9.7 150 FTG 4EG FE 1.3 SOURCE -3.0 SRCE 77.6 (N/A) 0.116 TL 57.50 PV NOTES: Calculations were performed by the HASS 7.6 computer program under license no. 5004004430 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.011 gpm and a maximum imbalance at any node of 0.078 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.4 ft/sec at pipe 2. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE.: 3/14/2005 C:\HASS76\BRESSI9TYP1.SDF JOB TITLE: PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B C A D N Eli Tee LngEli ChkVlv BfyViv GatViv AlmChk DPV].v NPTee 1.101 2.53 6.33 2.53 6.33 7.59 1.27 12.66 12.66 6.33 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Eli TeeRun Coupig SwgChk GatVlv NPTee 1.245 3.00 5.50 1.00 0.50 0.50 5.50 0.50 5.50 E 1. E4 9L) L) a, ) ow ) u,c40 •-I r. a, Q) Q. 4)CIQ D WU) •dwE - -1 Q.0 (0 C) D C) .c 4)0..14J 'a U) p-4C4-d00>1 U) V) :o -r.i I0oC/. WN ZZA 7A C/) F I 0 0 U) I DATE: 3/14/2005 JOB TITLE: SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 C:\HASS76\BRESSI9TYPl.SDF 0 0 0 0 LI) 0 0 lw IN o 0 0 0 0 0 0 p-I 0 C) 0 0 0 0 0 0 U) ko ('.1 p-I 00r) aj9wmwDgw —am -H— DATE: 3/14/2005 JOB TITLE: p WATER SUPPLY CURVE SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 C:\HASS76\BRESSI9TYP1.SDF 120+ 1100 <-110.0 psi @ 50 gpm I Flow Test Point 100+ 90+ P 80+ 1k X E I S I S 70+ U I 1k I E I 60+ ( I P I S I I 50+ ) I• 40+ 30+ 20+ LEGEND I I, I X = Required Water Supply I 77.60psi @ 42.0 gpm 10+ VI I 0 = Available Water Supply " 110.28 psi @ 42.0 gpm :: +------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) WESTERN STATES FIRE PROTECTION 9550 CHESAPEAKE DR. SUITE201 SAN DIEGO, CA. 92123 F HYDRAULIC CALCULATIONS V 4q FOR BRESSI RANCH PA-9 PLAN TYPE 2 AFILE NUMBER: BRESSI9TYP2.sdf ADATE: 12-6-04 -DESIGN DATA- OCCUPANCY CLASSIFICATION: Residential DENSITY: 0.05 GPM PER SQUARE FOOT AREA OF APPLICATION: 2 HYDRALICALLY MOST REMOTE SPRINKLER S COVERAGE PER SPRINKLER: 18' X 18' NUMBER OF SPRINKLERS CALCULATED: 2 TOTAL SPRINKLER WATER FLOW REQUIRED: 36.2 GPM TOTAL WATER REQUIRED (including hose): 41.2 GPM FLOW AND PRESSURE (@ SOURCE); 41.2 GPM 8 84.6 PSI SPRINKLER ORIFICE SIZE: 1/2" 4.9 K FACTOR CALCULATIONS BY MASS COMPUTER PROGRAM (LICENSE # 5004004430) MRS SYSTEMS, INC. TUCKER, GA 30084 CITY OF CARLSBAb FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions in Correspondence and conformce with applicable regulaticns. The stamping of these plans shall not be held to permit or ap?ae violation of any awl I Av (.'I'4.-.- DATE: 3/14/2005 JOB TITLE: WATER SUPPLY DATA SOURCE STATIC NODE PRESS. TAG (PSI) SOURCE 111.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 C:\HASS76\BRESSI9TYP2.SDF RESID. FLOW AVAIL. TOTAL REQ'D PRESS. 8 PRESS. 8 DEMAND PRESS. (PSI) (GPM) (PSI) (GPM) (PSI) 110.0 50.0 110.3 41.2 84.6 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 41.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 5.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 36.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 22.2 K= 4.90 13.5 18.0 2 22.2 K= 4.90 13.8 18.2 3 22.2 - - - - 15.4 - - - 4 22.2 - - - - 24.9 - - - 5 9.6 - - - - 33.7 TOR 9.6 - - - - 46.3 - - - U 3.5 - -- - 56.1 - - - A -3.0 - - - - 61.4 Ml 0.0 - - - - 72.4 - - - M2 0.0 - - - - 77.4 - - - SOURCE -3.0 SOURCE 84.6 36.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/14/2005 C:\HASS76\BRESSI9TYP2.SDF JOB TITLE: PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -18.0 1.101 PL 16.83 PF 1.9 1 22.2 4.9 13.5 18.0 6.1 150 FTG 2ET PE 0.0 3 22.2 0.0 15.4 0.0 0.056 TL 34.04 PV Pipe: 2 -18.2 1.101 FL 11.42 PF 1.6 2 22.2 4.9 13.8 18.2 6.1 150 FTG 2ET FE 0.0 3 22.2 0.0 15.4 0.0 0.057 TL 28.63 PV Pipe: 2A -36.2 1.101 FL 33.25 PF 9.5 3 22.2 0.0 15.4 0.0 12.2 150 FTG ET PE 0.0 4 222 0.0 24.9 0.0 0.204 TL 46.64 PV Pipe: 2B -36.2 1.101 FL 12.58 PF 3.3 4 22.2 0.0 24.9 0.0 12.2 150 FTC E FE 5.5 5 9.6 0.0 33.7 0.0 0.204 TL 16.41 PV Pipe: 2C -36.2 1.101 FL 39.08 PF 12.6 5 9.6 0.0 33.7 0.0 12.2 150 FTG E2T PE 0.0 TOR 9.6 0.0 46.3 0.0 0.204 TL 62.03 PV Pipe: 3 -36.2 1.101 FL 6.08 PF 7.1 TOR 9.6 0.0 46.3 0.0 12.2 150 FTC TA PE 2.6 U 3.5 0.0 56.1 0.0 0.204 TL 34.77 PV Pipe: 4 -36.2 1.245 FL 10.00 PF 2.5 U 3.5 0.0 56.1 0.0 9.5 150 FTG 4EG FE 2.8 A -3.0 0.0 61.4 0.0 0.112 TL 22.50 PV Pipe: 5 -36.2 1.245 FL 101.00 PF 12.3 A -3.0 0.0 61.4 0.0 9.5 150 FTG 35 FE -1.3 Ml 0.0 0.0 72.4 0.0 0.112 TL 110.00 PV Pipe: 6 FIXED PRESSURE LOSS DEVICE M2 0.0 0.0 77.4 0.0 5.0 psi, 36.2 gpm Ml 0.0 0.0 72.4 0.0 Pipe: 7 -36.2 1.245 FL 40.00 PF 5.9 M2 0.0 0.0 77.4 0.0 9.5 150 FTG 4EG FE 1.3 SOURCE -3.0 SRCE 84.6 (N/A) 0.112 TL 52.50 PV NOTES: (1) Calculations were performed by the HASS 7.6 computer program under license no. 5004004430 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/14/2005 C:\HASS76\BRESSI9TYP2.SDF JOB TITLE: The system has been calculated to provide an average imbalance at each node of 0.008 gpm and a maximum imbalance at any node of 0.080 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.2 ft/sec at pipe 3. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.101 2.53 6.33 2.53 6.33 7.59 1.27 12.66 12.66 6.33 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Eli Tee 45-Eli TeeRun Couplg SwgChk GatVlv NPTee 1.245 3.00 5.50 1.00 0.50 0.50 5.50 0.50 5.50 d) 0) E 0. Ei b D a) b'OO • WCJtD D O-1 •H 0 U )-la))U W 0. )a))cI)c o wu -dUE -4 Q - {OOU ZIZ .0 WQ.-I4-) (UO m 0cn ra r- Cfl -drlO>i ri , ' -4 •WCOtfl fliOb• U) 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 3/14/2005 C:\HASS76\BRESSI9TYP2.SDF JOB TITLE: 0 0 0 ri CSJ r- 0 0 0 0 0 -4 0 0 0 0 0 C) 0 C\1 0OD 'O -4 -4 ((rI C4 W U)U)1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/14/2005 C:\HASS76\BRESS19TYP2 .SDF JOB TITLE: WATER SUPPLY CURVE 120+ 1100 <-110.0 psi @ 50 gpm I Flow Test Point 100+ 90+ x P80+ R I E I S I S 70+ U I R I E I 60+ ( I P I S I I 50+ ) I 40+ 30+ 20+ LEGEND if I X = Required Water Supply IF I 84.61 psi @ 41.2 gpm IT 10+ of I 0 = Available Water Supply " 110.30 psi @ 41.2 gpm +------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) S WESTERN STATES FIRE PROTECTION 9550 CHESAPEAKE DR. SUITE201 SAN DIEGO, CA. 92123 HYDRAULIC CALCULATIONS FOR BRESSI RANCH PA-9 PLAN TYPE 3 "FILE NUMBER: BRESSI9TYP3.Sdf "DATE: 12-6-04 -DESIGN DATA- OCCUPANCY CLASSIFICATION: Residential DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@ SOURCE): SPRINKLER ORIFICE SIZE: 0.05 GPM PER SQUARE FOOT 2 HYDRALICALLY MOST REMOTE SPRINKLER 18' X 18' 2 36.7 GPM 41.7 GPM 41.7 GPM @ 74.0 PSI 1/2" 4.9 K FACTOR S CALCULATIONS BY MASS COMPUTER PROGRAM (LICENSE # 5004004430) MRS SYSTEMS, INC. TUCKER, GA 30084 CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions in Correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit or agROV118 violation of any lav DATE.: 3/14/2005 JOB TITLE: WATER SUPPLY DATA SOURCE STATIC NODE PRESS. TAG (PSI) SOURCE 111.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 C:\HASS76\BRESSI9TYP3.SDF RESID. FLOW AVAIL. TOTAL REQ'D PRESS. @ PRESS. @ DEMAND PRESS. (PSI) (GPM) (PSI) (GPM) (PSI) 110.0 50.0 110.3 41.7 74.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 41.7 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 5.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 36.7 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 4 22.2 K= 4.90 13.5 18.0 3 22.2 K= 4.90 14.5 18.6 2 22.2 - - - - 18.1 - - - 1 9.6 - - - - 27.0 - - - TOR 9.6 - - - - 41.0 - - - U 3.5 - - - - 50.9 A -3.0 - - - - 56.3 - - - Ml 0.0 - - - - 61.7 - - - M2 0.0 - - - - 66.7 - - - SOURCE -3.0 SOURCE 74.0 36.7 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/14/2005 C:\HASS76\BRESSI9TYP3.SDF JOB TITLE: PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -18.0 1.101 PL 61.33 PF 4.6 4 22.2 4.9 13.5 18.0 6.1 150 FTG 3ET PE 0.0 2 22.2 0.0 18.1 0.0 0.056 TL 82.37 PV Pipe: 2 -18.6 1.101 PL 43.58 PF 3.6 3 22.2 4.9 14.5 18.6 6.3 150 FTG 2ET PE 0.0 2 22.2 0.0 18.1 0.0 0.060 TL 60.79 PV Pipe: 2B -36.6 1.101 PL 12.58 PF 3.4 2 22.2 0.0 18.1 0.0 12.3 150 FTG E PE 5.5 1 9.6 0.0 27.0 0.0 0.209 TL 16.41 PV Pipe: 2C -36.6 1.101 PL 36.50 PF 14.0 1 9.6 0.0 27.0 0.0 12.3 150 FTG 3E2T PE 0.0 TOR 9.6 0.0 41.0 0.0 0.209 TL 67.10 PV Pipe: 3 -36.6 1.101 PL 6.08 PF 7.3 TOR 9.6 0.0 41.0 0.0 12.3 150 FTG TA PE 2.6 U 3.5 0.0 50.9 0.0 0.209 TL 34.77 PV Pipe: 4 -36.6 1.245 PL 10.00 PF 2.6 U 3.5 0.0 50.9 0.0 9.7 150 FTG 4EG PE 2.8 A -3.0 0.0 56.3 0.0 0.115 TL 22.50 PV Pipe: 5 -36.6 1.245 P1. 50.00 PF 6.8 A -3.0 0.0 56.3 0.0 9.7 150 FTG 3E PE -1.3 Ml 0.0 0.0 61.7 0.0 0.115 TL 59.00 PV Pipe: 6 FIXED PRESSURE LOSS DEVICE M2 0.0 0.0 66.7 0.0 5.0 psi, 36.6 gpm Ml 0.0 0.0 61.7 0.0 Pipe: 7 -36.7 1.245 PL 40.00 PF 6.0 M2 0.0 0.0 66.7 0.0 9.7 150 FTG 4EG PE 1.3 SOURCE -3.0 SRCE 74.0 (N/A) 0.115 TL 52.50 PV NOTES: Calculations were performed by the HASS 7.6 computer program under license no. 5004004430 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.009 gpm and a maximum imbalance at any node of 0.082 gpm. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/14/2005 C:\HASS76\BRESSI9TYP3.SDF JOB TITLE: Total pressure at each node is used in balancing the system. Maximum water velocity is 12.3 ft/sec at pipe 2B. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngE1l ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.101 2.53 6.33 2.53 6.33 7.59 1.27 12.66 12.66 6.33 PAGE: K MATERIAL: CT-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T F R C S G N Ell Tee 45-Eli TeeRurt Coupig SwgChk Gatvlv NPTee 1.245 3.00 5.50 1.00 0.50 0.50 5.50 0.50 5.50 31 Q. E4I-I ON 0) OOO ) O)-I •rI r) Wr-4QI IL) U)'iQE Q 0 D IL)U) dWE 0 -I ua, .Q WQ.LI4-) UZ U) r.i IC'4-dLflOi - h d •OtICI') IL0b. D Tw V SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 3/14/2005 C:\HASS76\BRESSI9TYP3.SDF JOB TITLE: 1 0 II t0 0 Lf t0 . 10 +0 tC) +0 IC4 I—I -. o 0 0 0 0 0 0 H 0 0 0 0 0 0 0 (%4 0CD W H H r] —04tfl-d--- AP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/14/2005 C:\HASS76\BRESSI9TYP3.SDF JOB TITLE: I WATER SUPPLY CURVE 120+ 1100.<-110.0 psi @ 50 gpm I Flow Test Point 100+ 90+ P 80+ R I E X S I S 70+ U I R I E I .60+ P I S I I 50+ ) I 40+ 30+ 20+ LEGEND I 'I I X = Required Water Supply 74.05 psi @ 41.7 gpm 10+ I 0 = Available Water Supply " I 110.29 psi @ 41.7 gpm +------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) Models Available UL/FM Models SSM24-6 SSM24-8 SSM24-1O SSVI2O-6 SSV12O-8 SSV12O-1O ULC/Canadian Models SSM246A SSM24SA SSM24-IOA SSVI2O-6A SSVI2O-8A SSV12O-10A Weatherproof Back Box WBB Product Overview SSV12O-6 Approved for for indoor and outdoor use System Sensor's SSM and SSV series bells are low current, high decibel notifi- Low current draw cation appliances for use in fire and burglary systems or other signaling appli- cations. High dB output Reliable Performance. The SSM and SSV series provide loud resonant tones. Three sizes available 6", 8", 10" The SSM series operate on 24VDC and are motor driven, while the SSV AC and DC models series operate on 120VAC utilizing a vibrating mechanism. DC models are polarized for use with Simplified Installation. For indoor use, the SSM and SSV series mount to a supervision circuitry standard 4 inch square electrical box. For outdoor applications, weather- proof back box, model number WBB, is used. Mount directly to standard 4" square electrical box The SSM and SSV series come pre-wired, to reduce installation time. The SSM series mcorporate a polarized electrical design for use with supervision circuitry. Englneedng Specifications Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 6"/8"/10" (specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi- flush mounting. Outdoor surface mounted installations shall be weather- proof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4" square electrical box having a maximum pro- jection of 211". Bells shall be located as shown on the drawings or as deter- mined by the Authority Having Jurisdiction. Bells shall be listed for Vi IC <> iVE IP!1V indoor/outdoor use by Underwriters Laboratories and the California State LTED WmVed Fire Marshal, and approved by Factory Mutual and MEA Standard Specifications Operating Temperature Range —31°F to 140°F Operating Voltage SSM series 24VDC SSV series 120VAC Termination Service Use Provided with 2 sets of leads for Fire Alarm in/out wiring. General Signaling Burglar Alarm Warranty 3 years Model Gong Diameter (inches) Nominal Voltage Operating Voltage Range Maximum Current (at Rated Voltage) Sound Output (dB) SSM24-6 6 85 SSM24-8 8 24VDC 19.2 to 26.4VDC 0.024A 85 SSM24-10 10 86 SSV120-6 6 83 SSV120-8 8 120VAC 96 to 132VAC 0.032A + 10% 78 SSVI20-10 10 85 * Sound output measured at Underwriter Laboratories, as specified In UL464 Ordering Information UL/FM Model Numbers ULC/Canadian Models Description SSM24-6 SSM24-6A Bell, 6°, 24VDC, Polarized, 85dba SSM24-8 SSM24-8A Bell, 80, 24VDC, Polarized, 85dba SSM24-10 SSM24-IOA Bell, 10°, 24VDC, Polarized, 86dba SSVI2O-6 SSVI20-6A Bell, 68, 12OVAC, 83dba SSV120-8 SSV120-8A Bell, 80, 12OVAC, 78dba SSV120-10 SSVI20-I0A Bell, 10°, 12OVAC, 85dba WBB Weatherproof Back Box for SSM and SSV series, when installed outdoors System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Ac: 630/377.6495 Documents-on-Demand 800/736-7672 x3 www.systemsensor.com System Sensor Canada Ph: 905.8120767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sensor In China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor In Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor - Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor - Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor - India Ph: 91124.637.1770 x.2700 Fx: 91.124.637.3118 'WWJ Th. 4. 4.. ......_.., ..,..• ......, F1 Res 49&58 Recessed Pendent/ F1 Fl Res 49 CCP Pendent Bulletin 135 Rev.D neolmin Model Fl Residential Sprinklers Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpmat Types: F1 Res 49Pendent Fl Res 49 Recessed Pendent/171 Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Pendent/Fl Fl Res 49 CCP Pendent Fl Res 44 HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSW Recessed HSW/F2 11, F1 Res 44SWC Fl Res 40 HSW Fl Res 40 Recessed HSW/F2 Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1,2,3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and tow profile decorative design. The Fl Res Horizontal Sidewall sprinklers (Figs. 5,6 & 7) are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers, with a K-Factor of 4.9, permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow El Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard *) Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Fl Res 49 Recessed Pendent / FP Fl Res 44&58 Recessed HSW/F2 Fl Res 44 SWC Fl Res 40 Recessed HSW/F2 Technical Data: Thermal Sensor: Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: /2" NPT ® ½) K-Facr: 4.9 (Actual) - Fl Res 49 Pendent Spunkier 5.8 (Actual) - Fl Res 58Pendent&HSpñnkIer 4.4 (Actual) - Fl Res 44 HSW Spnkler 4.0 (Actual) - Fl Res 40 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Application Model Fl Res Sprinklers are used for Residential Fire Protection according to UL 1626 Standard*. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. * Effective date 7/12/02 The Reliable Automatic nrinkIr Cn. 1nr_.!;?5 North M'Oiiaqtn Prkwv Mount VArnon Ne.w Ynrk1flF52 Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pendent sprinklers use only the Model 0 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR1 sprinkler wrench; for installing Model Fl Res Recessed HSW sprinklers use only the Model GFR1 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 and 40 HSW with a ceiling to deflector distance of 4"- 12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling. Model F1 Res 49 & 58 Model Fl Res 49 & 58 Pendent Recessed Pendent / Fl Fl escutcheon, (19mm) adjustment Fig 1 Fig.2 2. Technical Data: Fl Res 49 Pendent and Recessed Pendant Thread Sprinkler Temp. Max. Max. Arnbjent Actual Sprinkler Size Rating Pressure Temp. K Length psi (bar) Factor Inch (mm) OFIOC __ F___ y'NPT (R}) 1551 175 68 I 79 175(12) OF 100 150 i 38 I 66 4.9 2.25(57) Escutcheon*. Fl or F2, Data: AdJuslmerd "A" Faceofllthngto Type inch (MM) Inch (MM) inch (nm) Fl % (19.0) Min.= %" (19.1) Max.=1W (38.1) 1 ,, -15,f6 (4.7-24.0) tF2 )'2 (12.7) Min.= % (23.8) Max.=1" (38.1) 3X6 -,)(6(4.7-17.4) * Note: Escutcheons Fl or F2 may be used with Model Fl Res 49 & 58 Recessed Pendent Sprinkler Ddlector - to - ceiling Maximum 1" (ITm) to 4" (100iim) Max. Sprinkler Spacing ft _(m) Row gpm (Lpm Pure psi (bar) ______ Sprinkler Identification) Number (SIN) 12 x 12 (3.6x3.6) 13(49) 7.0(0.48) R3516 16.7(1.14) 14 x 14 (4.3x4.3) 13(49) 7.0(0.48) 16 x 16 (4.9x4.9) 13(49) 7.0(0.48) 18 x 18 (5.5x5.5) 17(64.3) 12.0(0.83) 20x20(6.14.1) 20(75.7) Maximum Cr (1Om) to 8" (mm) Max. Sprin ng kler Spaci ft (m) Row 9J)fll (Lpm) Pressure psi (bar) Sprinkler Identifion Num cati ber (SIN) 12 x 12 (3.6x3.6) 15(57) 9.4 (0.65) R3516 20.2(1.4) 14 x 14 (4.3x4.3) 16(60.5) 10.6(0.73) 16x 16(4.9x4.9) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5x5.5) 19(72) 15.0(1.0) 20x20(6.1x6.1) 22(832) *Note The Fl Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: Maximum beam depth = 7 (178mm) Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: Fl Res 58 Pendent and Recessed Pendent Thread Spfwft Temp. Max. Max. Ambient K SpiWiler Size Rating Pressure Temp. Factor LerKA psi (baa OF inch (nm) OFI OC IOC ½NPT (R½) 1551 1751 68 79 175(12) iool 150 38 I 66 58 2.25(57) Max. Sprinkler Spacing ft (m) Flow n(Lpm) Pressure psl(ba) CeIling -ID- De kich (mm) Sprinkler kl entification 12 x 12 (3.6x3.6) 16(61) 7.6(0.53) 1-4 (25-100) 14.4(1.0) 113 14 x 14 (4.3x4.3) 16(61) 7.6(0.53) 16 x 16 (4.9x4.9) 16(61) 7.6(0.53) 18 x 18 (5.5x5.5) 19(72) 10.8(0.75) 20x20(6.1x6.1) 22(83.3) 3. UA "B" Cover Adjustment CCP Height Inch (mm) Inch (mm) 3(12.7) 1!4r, (24) 3(6(4.7) %(19) FP Data "A": FP Position Inch (mm) I Max. Recessed I via (11) Mm. Recessed I % (24) I Note: Sprinklers shown in Fig. 3 and 19g. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Model Fl Res 49 CCP • Model F1 Res 49 Recessed Penaent SI.:, -: FP push-on/thread-off escutcheon 2 5/16 DL'.. • 2 5/8 [5&7-1DJA. 15&7--] - ___________ HOLE IN aILING CUP 1TEi tW/2RaI1cER CUP Hwjir \ \ cam OK FACE OF RTMG W FACE OF CMW coRSWEff S 5/I6 DL( (84.1mm) UAWS Fl RES 49 CCP PEND. Li Fig. 3 Technical Data: Fl Res 49 CCP and FP CCP Options Data: Sprinkler CCP Max. Thread Size Temp. Rating Assen"PJieIL Temp. Rating P,essuie Ambient ip. K Factor Sprinkler Length pal (bar) bich(m) OFI OC 0F10C OFI OC WNPT 155 68 135 57 175(12) 100 1 38 F __ .... _ 2.25(57) Max. Sprinkler Spacing ft (m) Raw Pressure pQu) Sprinkler Idertficalkm 12 x 12 (3.6x3.6) 13(49) 7.0(0.48) R3516 16.7(1.14) 14 x 14 (4.3x4.3) 13(49) 7.0(0.48) 16 x 16 (4.9x4.9) 14(53) 82(0.56) 18x 18(5.5x5.5) 18(68.1) 13.5(0.93) 20x20(6.1x6.1) 20(75.7) 4. Model F1 Res 44 & 58 HSW Model F1 Res 44 & 58 Recessed HSWIF2 F2 escutcheon, Technical Data: Fl Res 44 HSW & HSW/F2 Escutcheon. F2. Data: Adment' FaeofMeS A I Type kich (m n) I to won I kich Mn) I F2 X(13 l% (4.7-17.4)1 - MeL mrai Tnp. MeL Ambient K Spiinklei' Sim Rath Presswe Ten. FIor Les4h psi (bat) bich (m) ¶ 1 CC ¶ CC Y2"NPT (R½) 155168 175 I 79 175 (12) 100138 iso 66 4.4 2.45(62) der ft(m) UAU ceilkg4o- ri kich(imi) Sp iinIderTen RON Flow () Spñikler 12 x 12 (3.6x3.6) 4-6 (101-152) 155(68) 175(79) 12(45.4) 7.5(0.52) R3531 14 x 14 (4.3x4.3) 155(68) 175 (79) 14(53.0) 10.2(0.71) 16 x 16 (4.9x4.9) 155(68) 175(79) 16(60.6) 13.3(0.92) 16x 18(4.9x5.5) 155(68) 175(79) 18(68.1) 16.8(1.16) 18 x 18 (5.5x5.5) 155(68) 175(79) 19(72.0) 18.7(1.29) 16 x 20 (4.9x6.1) 155(68) 175(79) 23(87.1) 27.4(1.89) 12 x 12 (3.6x3.6) 6-12 (152-305) 155(68) 175(79) 14(3.0) 10.2(0.71) 14 x 14 (4.3x4.3) 155(68) 175(79) 16(60.6) 13.3(0.92) 16 x 16 (4.9x4.9) 155(68) 175(79) 17(64.4) 15.0 (1.04) 16 x 18 (4.9x5.5) 155(68) 175(79) 20(75.7) 20.7(1.43) 16x20(4.9x6.1) 155 (68) 175(79) 23(87.1) 27.4(1.89) 5. Escutcheon. F2. Data:. I T I ype iAcrjushiieil Faeo(FIthng I towI I kids (m) I. (nm) I F2 I 3(13) 3f1X6 (47 17.4) Technical Data: Fl Res 58 HSW & HSW/F2 M. Temp. MaL Ambient ic Si Ralinq Preemie Tei.Factor Owjoc 611ac W'NPT (R½) 155168 175 175(12) 100138 iso I 66 5.8 2.45(62) MaLSpdnlder ft(m) "A" Deflector Inc h(nmi) SpclnklerTenip. "(,q I-.- m(Lpm) psbre Spdnkier 12 x 12 (3.6x3.6) (101-152) 175(79) 16(60.6) 7.6(0.53) R3533 14 x 14 (4.3x4.3) W15568 175(79) 18(68.2) x 16 (4.9x4.9) 9.7(0.674-616 175(79) 21(79.5) 13.2(0.91) 16 x 18 (4.9x5.5) 155 (6B) 175(79) 25(94.7) 18.6(1.28) 16 x 20 (4.9x6.1) 155(68) 175(79) 29(109.8) 25(1.73) 12x12(3.6x3.6) 6-12 (152-305) 155(68) 175(79) 22(83.3) 14.4(1.0) 28.6(1.97) 14 x 14 (4.3x4.3) 155(68) 175(79) 22(83.3) 14.4(1.0) 16 x 16 (4.9x4.9) 155(68) 175(79) 26(98.4) 20.1(1.39) 16x 18(4.9x5.5) 155(68) 175(79) 31(117.4) .1 5/I5 (8&Un'mj Lw.. "M COUM im -, T lTAG4A5T9.LRwamw . '.1 121J2 IAPW —4 v2g, AM— Fl RES 44 SWC Fig.5 Technical Data: Fl Res 44 SWC m.ac size Spdnkler Ten. Raliriq cover Ten. Baling Press= MaL MtlentTen Length F Inch (mm) 0F 10C OF I°c OF cc :11/12"N~ PT 155 68 1 135 57 175 (12) 100 , 38 4.4 245(62) Ma ft(m) "A" celng4 kich(mm) Rm gpfln) Pieenue p _______________ Id5flblibOfl 12 x 12 (36x3.6) 4-6 (101152) 13(49.2) 8.7(0.60) R3531 20.7(1.43) 14 x 14 (4.3x4.3) 14(53.0) 10.2(0.71) 16x16(4.9x4.9) 17(64.3) 15.0(1.1) 16x 18(4.9x5.5) 19 (71.8) 18.7(l.13) 16 x 20 (4.9x6.1) 23(87.1) 27.4(1.89) 12x 12(3.6x3.6) 6-12 (152305) 14(52.9) 10.2 (0.71) 14 x 14 (4.3x4.3) 15(56.7) 11.7(0.81) 16 x 16 (4.9x4.9) 18(68.1) 16.8(1.16) 16 x 18 (4.94.5) 20(75.6) 7. Model F1 Res 4OHSW 135FG05 Model F1 Res 4ORecessed HSW/F2 F2 escutcheon, r"4 FACE OF FPTh?K 10ML AIVOW 2 114- ac 10 (31.8mm) I' X 112" RERCM --7 DANNOW W ,Z4. (57.8mnJ (2mm I I5/I60it1 -- (49.2mm) - 2 27/32 L( I I (72mm) 1W4 OMM UNIM. — ir .igrwRom am swwqgu '. -.4 f Fl RES 58. 44 & 40 HSW/F2 Fig. 6 Fig. 7 Technical Data: Fl Res 40 HSW & HSW/F2 Escutcheon. F2 Data: Tlnad WNW Temp. MaL Alex K Spliflkiel She —Raft Presswe Ten. Factor Length psi (ba) 1 ___ ich(niu) 01: cc ¶1cc Y2"NPT (R Y2) 155168 1 175 I 79 1 175(12) 100138 150 I 66 1 4.0 2.45(62) Mjusbnent' FaoeOfFltthg I Type km I (mm) to wall I k th (mm) I F2 X(13) I3( -%(4.7-17.4)I MaLSpdnkler Iwo 4b- SpdnkIerTemp Raw --- ft(m) Deftector Rathig °F(°c) 9pm (Lpm) psi (bsi I m imber(Stt hich(nin) 12 x 12 (3.6x3.6) 4- 6 (101-152) 155(68) 175(79) 13(49.0) 10.6(0.73) R3538 14x 14(4.3x4.3) 155(68) 175(79) 16(60.5) 16.0(1.10) 16x 16(4.9x4.9) 155 (68) ______ 17(64.3) 18.1(1.24) 16x 16(4.9x4.9) 175 (79) 18 (68.1) 20.2(1.39) 16 x 18 (4.9x5.5) 155(68) 175 (M 20(75.7) 25.0(1.72) 18 x 18 (5.5x5.5) 155(68) 175(79) 22(83.3) 30.2(2.08) 16 x 20 (4.9x6.1) 155(68) 175(79) 23(87.0) 33.1 (2.28) 12 x 12 (3.6x3.6) - 6 12 (152-305) 155(68) 175(79) 13(49.0) 10.6(0.73) 14 x 14 (4.3x4.3) 5(68) 175(79) 17(64.3) 18.1(1.24) L15 16 x 16 (4.9x4.9) 155(68) 175(79) 20(75.7) 25.0(1.72) Finiihes" Standard Finishes Sprinkler Fl, FZ FP Escutcheons Bronze Brass Chrome Plated Bright Chrome Plated White Polyester Coated White Painted Special Application Finishes Sprinkler Fl, F2, Escutcheons Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome W Other finishes and colors are available on special order. Consult factory for details. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Maintenance Model Fl Res 49, Fl Res 58, Fl Res 44 and Fl Res 40 Sprinklers should be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl RES 49 Residential Sprinkler Specifications Model Fl Res 49 Pendent Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gprrVft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be l"to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish.- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 49, SIN R3516 (Bulletin 135). Model Fl Res 49 Recessed Pendent/Fi, Model Fl Res 49 Recessed Pendent/F2, Model Fl Res 49 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)1 low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gprrilff over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2' NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.9(70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model 172)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with 1/2" adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 49 Recessed Pendent/F1] [Model Fl Res 49 Recessed Pendent/172] [Model Fl Res 49 Recessed Pendent/FP] SIN R3516 (Bulletin 135). Model Fl Res 49 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as Specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1/2" cover plate adjustment. Cover plate temperature rating shall be 135°F (571C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 49 CCP, SIN R3516 (Bulletin 135). Model F1RES4Oand Fl Res 44 Horizontal Sidewall Residential Sprinkler Specifications Model Fl Res 40 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineere,ç to provide a minimum design density of 0.05 gpm/ff over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.0 (57.1). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 40, SIN R3538 (Bulletin 135). Model Fl Res 40 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 40 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model 172). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 40/F2, SIN R3538 (Bulletin 135). Model Fl Res 44 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93E)] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ff over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.4(62.8). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, SIN R3531 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by REUASLE have been protecting file and property foro er8D years, and are installedand serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Spunkier Co., Inc. (800) 431-1588 Sales Offices Recycled (800) 848-6051 Sales Fax is Paper (914) 668-3470 Corporate Offices Revision lines indicate updated or new data. wwi.mlishlesorin)der.cnm Internet Address EG. Printed in U.S.A. 8104 PIN 9999970235