Loading...
HomeMy WebLinkAbout1925 DOVE LN; ; AS03021910/8/2020 AS030219 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS030219 Job Address: 1925 DOVE LN Status: ISSUED Permit Type: SPRINK Applied 10/28/2003 Parcel No: 2150521500 Approved: 1/14/2004 Lot #: 0 Reference No.: Issued: 1/14/2004 PC #: Inspector: Project Title: LA COSTA GREENS OH AS PLAN CHECK & INSPECTIONS Applicant: Owner: REAL ESTATE COLLATERAL MANAGEMENT Co C/O LIZ LAYMAN/ MORROW DEV 1903 WRIGHT PL #180 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 650.75 0 650.75 0 Ill LIFEGUARD FIRE PROTECTION, I*J. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA (760) 806-9997 •. FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: '1925 Dove Lane Building: #8 System No. Carport Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP8 Construction: J9 Combustible LI Non-Combustible Ceiling Height 8'-0" Ft. II NFPA13: o NFPA 231 o Other (Specify) DSpecific Ruling 5YS1tM DIS1UN [I Light Hazard Ordinary Hazard Group 0 NFPA23IC: Figure: Area reduced per NFPA 13 Section 7-2.3.2.4 Made By 1 U 2 II 3 ll Extra Hazard Curve: Date Area of Sprinkler Operation 900 sq ft System Type Density .15 Z Wet 0 Dry 0 Deluge 0 Pre-Action Area Per Sprinkler 125 sq ft . Sprinider or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model LFII. Hose Allowance GPM: Outside 250 Size .1/2" K-Factor: 4.9 Rack Sprinider Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 156.21 PSI Required 65.71 At City Connection "C" Factor Used: Overhead 120 Underground 150 I :i !'1 II A Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a . Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 Well Elevation 190' . Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department WMMUL)IiY SIOI(AUE Commodity . Class Storage Height Area Storage Method: Solid Piled % Palletized Location - Aisle Width % Rack Rack O Single Row 0 Conventional Pallet 0 Automatic Storage 0 Encapsulated O Double Row 0 Slave Pallet 0 Solid Shelving 0 Non-Encapsulated Multiple Row El Open Flue Spacing In Inches Clearance From Top of Storage to Ceiling Longitudinal . • Transverse Ft. In. Horizontal Bathers Provided 1 • Costa Greens Carport.15/900 Sigma Dynamlos Corporation 7700 Supply I Demand Graph 1. : :B l dg Margin Pressure 1.70 PSI '1F1ow 404.69 GPM -- ___ -- ..-.. .. .. ..- - -.___ ___ ___ ___ ____. _ ___ ____ _ 2)0 400 600 800 1000 1200 1400 1600 - 10O . 2000 Wator Flow (GPM) System Demand.. . . . . . Water Supply.. Sprinkler Demand 82.10 PSI e 156.21 GPM Static 64.80 PSI Additional Flour 250.00 GPM . Residual 57.60 PSI S 1480.00 GPM Hose at Source 0.00 GPM . Elevation 0.00 PSI . Total Demand 62.44 PSI 5 406.21 GPM 03-09-2002 PAGE 1 SUBMITTAL SERIAL NO: 2932HY4 La Costa Greens Building #8 Carport .15/900 FLOW TEST RESULTS Water Supply STATIC 64 ,80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE AVAILABLE AT 406.2 GPM SUMMARY OF SPRINKLER OUTFLOWS ACTUAL. MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 101 20.59 18.75 5.60 13.52 102 19.96 18.75 5.60 12.70 103 19.65 18.75 5.60 12.32 104 19.57 18.75 5.60 12.21 105 19.74 18.75 5.60 12.42 106 19.12 18.75. 5.60 11.66 107 1.8.83 1.8. 7-5 5.60 11.31 108 18.75 18.75 5.60 .11.21 64.14 PSI TOTAL WATER REQUIRED FOR:.. SYSTEM OUTFLCWS AT 4 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE. UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 20 TO 101 1:56.2:1, GPM 250.00 GPM 406.21 GPM 62.44 PSI 0.0•0 PSI 14.12 FPS SUBMITTAL SERIAL NO:2932HY4 .03-09-2002 PAGE 2 La Costa Greens Building: #8 Carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & .Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 104 108 1.080 L 10.00 C=120 PT 11.21 (108) Q 18.75 F=0 F 0.00 PE 0.00 BN T 10.00 0.1002 PF 1.00 23 104DQ 19.57 1.080 L 5.25 C=120 -PT 12.21 (104) Q 38.32 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3760 PP 5.02 ------------------ PT 17.55 ( 23) 103 107 1.080 . L 10.00 C=120 PT 11.31 (107) Q 18.83 F=0 F 0.00 PH 0.00 BN . T 10.00 0.1010 PP.. 1.01 22 103DQ 19.65 1.080 L 5.25 C=120 PT 12.32 (103) Q 38.49 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3790 PF 5.06 PT 17.70 ( 2.2) 102 106 1.080 L 10.00 C=120 PT 11.66 (106) Q 19.12 F=0 F 0.00 PE 0.00 BN T 10.00 0.1039 PP 1.04 21 102DQ 19.96 1.080 L 5.25 C=120 PT 12.70 (102). Q 39.08 F=T,E F 8.10 PE 0.32 BN T 13.35 0.3900 PP 5.21 ------------------ PT 18.23 ( 21) 10]. 105 1.080. L 10.00 C=120 PT 12.42 (105) Q 19.74 F=0 F 0.00 PE 0.00 BN T 10.00 0.1102 PF 1.10 20 101DQ 20.59 1.080 L 5.25 C=120 PT 13.52 (101) Q 40.33 F=T,E F 8.10 PE 0.32 BN T 13.35 0.4133 PF 5.52 PT 19.36 C 20) 5 4 7.758 L 174.00 C=150 PT 62.03 C 4) Q 155.42 F=0 F 0.00 PE 0.00 LU T 174.00 0.0002 PF 0.03 6 5 7.758 L 415.00 C=150 PT 62.06 ( 5) Q 155.42 F=GV,2EE./2EE F 60.40 PE 0.00 LU T 475.40 0.0002 PF 0.10 7 6 7.758 L 623.00 C=150 PT 62.16 1 6) Q 155.42 F=EE,GV/EE,Gv,2.EE F 66.44 PE 0.00 LU T 689.44 0.0002 PF 0.14 SUBMITTAL SERIAL NO:2932HY4 03-09-2002-PAGE 3 La Costa Greens - Building #8 carport .15/900 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 8 7 7.758 L 220.00 C150 PT 62.30 ( 7) Q 155.42 F=GV F 6.04 PR 0.00 LU T 226.04 0.0002 PF 0.05 3 8 7.758 L 158.00 C=150 PT 62.35 ( 8) Q 155.42 F=GV,EE/GV,T F 78.57 PR 0.00 LU T 236.57 0.0002 PF 0.05 1 3 7.758 L 1.00 C=150 PT 62.40 ( 3) Q 155.42 F=0 F 0.00 PE 0.00 LU T 1.00 0.0002 PF 0.00 PT 62.40 ( 1) 2 ------------------ 4 7.758 L 596.00 C=150 PT 62.03 ( 4) Q 250.79 FT,GV,4EE/GV,2EE F 146.52 PR 0.00 LU T 742.52 0.0005 PF 0.37 1 2 7.758 . L 1.00 C=150 PT 62.40 1 2) Q 250.79 F=0 F 0.00 PR 0.00 LU T 1.00 0.0005 PF 0.00 • . . PT 62.40 ( 1) 22 ------------------ 23 2.203 L 12.50 C=120 PT 17.56 ( 23) Q 38.32 .F=0 F 0.00 PR 0.00 FM T 12.50 0.0117 PF 0.15 21 22DQ 38.49 2.203 L 12.50 C=120 PT 17.71 ( 22) Q 76.81 F=0 F 0.00 PR 0.00 • P14 T 12.50 0.0423 PF 0.53 20 21DQ 39.08 2.203 L 12.50 C=120 PT .18.24 C 21) Q 11589 F=0 F 0.00 PR 0.00 FM T 12.50 0.0905 PF 1.13 18 20DQ 40.33 2.203 L 90.00 C=120 PT 19.37 1 20) • Q 156.21 F=T,8E/T F 61.60 PR -0.87 FM T 151.60 0.1572 PF 23.83 17 18 2.203 L 63.00 C=120 PT 42.33 1 18) Q 156.21 F=T/T F 23.20 PR 0.00 • • FM T 86.20 0.1572 PF 13.55 16 17 3.314 L 20.00 C=120 PT 55.88 1 17) Q 156.21 F=8E F 58.40 PR 0.87 FM • T 78.40 0.0215 PF 1.69 I I SUBMITTAL SERIAL NO: 2932HY4 03-09-2002 PAGE 4 La Costa Greens Building *8 carport .15/900 Location Flow Pipe Fittings Eqüiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 15 16 3.314 L 116.00 C=120 PT 58.44 (.16) Q 156.21 F=2E/T F 33.50 PE 0.00 FM T 149.50 0.0215 PF 3.21 11 15 3.314 L 7.58 C=120 PT 61.65 ( 15) 0 156.21 F=cV,E F 28.85 PE 3.28 FR T 36.43 0.0215 PP 0.78 10 11 4.280 L 7.00 C=140 PT 65.71 ( 11) Q 156.21 F=E F 17.92 PE 0.00 UN T 24.92 0.0047 PF 0.12 9 10 4.266 L 23.00 C=15.0 PT 65.83 ( 101 Q 156.21 F=T F 38.42 PE 0.00 UN T 61.42 0.0042 PP 0.26 4 9 4.266 L 79.00 C150 PT 66.09 ( 91 Q 156.21 F=T,GV,DDC/3E F 99.89 PE -.19.50 1.fl1 r . • OCI ' U U fl V • flVfV t' 4) T 1.' ( •1 V 4" Watts 909 RPDA 14.69 • PT 47.34 ( 4) 0 1 . 7.758 L 1.00 C=150 PT 62.44 ( 11 Q 406.21 F=0 F 0.00 PE 0.00 UN T 1.00 0.0013 PF 0.00 PT 62.44 ( 0) I. LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92.056 (760) 806-9997 . FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens Date: 03/24/04 Location: 1925 Dove Lane Building: #8 System No. 2-head Contractor: Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP8 Construction: 0 Combustible . Li Non-Combustible Ceiling Height 8'-0" Ft. SYSTEM DESIUN NFPA 13: Li Light Hazard Ordinary Hazard Group II 1 II 2 U 3 LI Extra Hazard O NFPA 231 0 NFPA 231C: Figure: Curve: O Other (Specify) Specific Ruling Residential tsia1e By .. Date Area of Sprinkler Operation 2-head System Type Density .10 . . Wet 0 Dry 0 Deluge 0 Pre-Action Area Per Sprinlder 20' x 20' .. Sprinider or Nozzle Hose Allowance GPM: Inside 0 Make Tyco Model . LFII Hose Allowance GPM: Outside Size 1/2" K-Factor: 4.9 Rack Sprinider Allowance n/a Temperature Rating 155 CALCULATION SUMMARY GPM Required 40.21, PSI Required 56.22 At City Connection "C" Factor Used: Overhead 120 . Underground 150 Water Flow Test Pump Data . Tank or Reservoir Date & Time 10/17/03 10:45am Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual-PSI 64 Elevation n/a GPM flowing 1480 . . fl Elevation 190' Proof Flow n/a GPM Location . Point of connection at existing main in Dove Lane Source of Information Carlsbad Fire Department COMMODITY STORAUE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized % Rack - Rack 0 Single Row 0 Conventional Pallet 0 Double Row 0 Slave Pallet 0 Multiple Row 0 Open Flue Spacing In Inches Longitudinal . Transverse Horizontal Bathers Provided O Automatic Storage Li Encapsulated O Solid Shelving 0 Non-Encapsulated Clearance From Top of Storage to Ceiling Ft. In. La Costa Greens Bldg #8 2-head caic Sigma Dynamics Corporation rroo supply I Demand Graph 12,1 .1 ..4iAargln Pressure 13.93 PSI IIJ LFlow 2074.218 GPM .Ic -.-----------. --.----. __ -----.- ,-.-.---- ---.-- -.--- . - ...-.-....-.-.. ..-...-.-..- -..----..-.-... — .----.------..--------.-.-..---.---.------.. -- —.-- -- - .---.- -- - -..- ..----.- ...------- -.-- . - - N1J5 200400 600 800 1000 12O0 400 low--- 1000 . 2000 1.y Stern Demand... SPrr*iew' Demand AddRIcn1 Flows Hose at Source Total Demand 50.86 PSI e 40.21 GPM 0.00 GPM 0.00 GPM 50.86 PSI 0 40.21 GPM Water Flow (GPM) Water Supply.. Static 64.80 PSI Residual 57.60 PSI S 1480.00 GPM Elevation 0.00 PSI SUBMITTAL SERIAL NO:2932HY4 La Costa Greens Building #8 third floor 2.-head caiculaton 20.1 x 20' spacing FLOW TEST RESULTS Water Supply STATIC 64.80 PSI RESIDUAL 57.60 PSI @ 1480.00 GPM CITY PRESSURE. AVAILABLE AT 40.. 2 GPM. SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW . FLOW: K-FACTOR PRESSURE 162 20.00 20.00 4.90 16.66 163 20.21 20.00 4.90. 17.02 03-09-2002 PAGE 1 64.7 9 PSI TOTAL WATER REQUIRED FOR SYSTEM TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 150 TO 151 40.21 GPM 40.21 GPM 5:0.86, PSI 0.00 PSI 13.55 FPS SUBMITTAL SERIAL NO:2932RY4 03-09-2002 PAGE 2 La Costa Greens Building #8 third floor 2-head caiculaton 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 161 162 1.101 L 13.00 C=150 PT 16.66 Q 20.00 F=DPV,E F 6.00 PE 0.00 AO T 19.00 0.0680 PF 1.29 ------------------ PT 17.95 (161) 161 163 1.101 L 7.50 C=150 PT 17.02 Q 20.21 F=DPV,E F 6.00 .PE 0.00 AO T 13.50 0.0694 PF 0.94 160 161DQ 20.00 1.101 L 2.00 C=150 PT 17.96 (161) Q 40.21 F=E F 5.00 PE 0.22 EN1 T 7.00 0.2477 PF 1.73 153 160 1.101 .L 32.00 C=150 PT 19.91 (160) Q 40.21 F=E,DPV,2E/DPV,E F 22.00 PE 0.00 • D'L.. ' i. r • - " r1- rr ' - -, c ------------------ PT 33.29 (153) 150 151 1.101 L 1.75 C=150 PT 46.72 (151) Q 40.21 F=T/F- F 10.00 PE 0.32 BN T 11.75 0.2477 PF 2.91 ------------------ PT 49.95 (150) 5 4 7.758 L 174.00 C150 PT 50.85 ( 4) Q 15.23 F=0 F 0.00 PE 0.00 LU T 174.00 0.0000 PF 0.00 6 5 7.758 L 415.00 C=150 PT 50.85 ( 5) Q 15.23 F=GV,2EE/2EE F 6.0.40 PE 0.00 LU T 475.40 0.0000 PF 0.00 7 6 7.758 L 623.00 C=150 PT 50.85 ( 61) Q 15.23 F=EE,GV/EE,GV,2EE F 66.44 PE 0.00 LU T 689.44 0.0000 PF 0.00 8 7 7.758 L 220.00 C=150 PT 50.85 ( 7) Q 15.23 F=GV F 6.04 PE 0.00 LU T 226.04 0.0000 PF 0.00 3 8 7.758 L 158.00 C=150 PT 50.85 ( 8) Q 15.23 F=GV,EE/Gv,T F 78.57 PE 0.00 LU T 236.57 0.0000 PF 0.00 1 3 7.758 L 1.00 C=150 PT 50.85 ( 3) Q 15.23 F=0 F 0.00 PE. 0.00 LU T 1.00 0.0000 PF 0.00 PT 50.85 1 1) SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 3 La Costa Greens Building #8 third floor 2-head calculaton 201 x 2.0.' spacing Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss . Summary From To GPM IN Devices Ft PSI/Ft PSI 2 4 ------------- 7.758 L 596.00 C=150 PT 5085 1 4) Q 24.98 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PF 0.00 1 2 7.758 L 1.09 C=150 PT 50.85 1 21 0 .24.98 . F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF• 0.00 PT 50.85 ( 1) 152 153 1.101 L 10.00 C=150 PT 33.28 (153) Q 40.21 F=DPV F 1.00 PE 4.33 FRi T 11.00 0.2477 PF 2.72 151,152 . 1.101 L 9.00 C=150 PT 40.33 1152.) 0 40.21 F=DPV F 1.00 PE 3.90 FRI . T 10.00 0.2477 PF 2.48- PT 46.71 (151) 18 150 - -- 2.203 L 63.00 C=120 PT 49.95 (150) Q 40.21 . F=T,8E F 58.00 PE -0.87 FM T 113.00 0.0128 PF 1.45 17 18 2.203 L 53.80 C=120 PT 5.0.53 1 18) 0 40.21 F=T/T F 23.20 FE 0.00 FM T 86.20 0.0128 PF 1.10 -16 17 3.314 L 20.00 C=120 PT 51.63 1 17) O 40.21 F=8E F 58.40 FE 0.87 FM T 78.40 0.0017 PF 0.13 15 16 3.314 L 114.00 C=120 PT 52.63 1 16) O 40.21 F=2E/T F 33.50 FE 0.00 FM T 149.50 0.0017 PF 0.25 11 15 3.314 L 7.58 C=120 PT 52.88 1 15) Q . 40.21 F=cV,E F 28.85 FE 3.28 FR T 36.43 0.0017 PF 0.06 10 11 . 4.280 . L 7.00 C=140 PT 56.22. ( 11) o 40.21 F=E F 17.92 FE 0.00 UN T 24.92 0.0004 PF 0.01 9 10 4.266 L 23.00 C150 PT 56.23 1 10) O 40.21 F=T F 38.42 FE 0.00 UN T 61.42 0.0003 PF 0.02 SUBMITTAL SERIAL NO:2932HY4 03-09-2002 PAGE 4 La Costa Greens Building #8 third floor 2-head calculaton 20' x 20' spacing Location Flow Pipe Fittings Equiv Friction - Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 4 9 4.266 L 79.00 C=150 PT 56.25 1 9) Q 40.21 F=T,GV,DDC/3E F 99.89 PE -19.50 UN. T 178.89 0.0003 PF• 0.05 4" Watts 909 RPDA 14.02 PT 16.80 C OA F A -------------------- 0 1 7758 L 1.00 C=150 PT 50.86 1 1) Q 40.21 F=0 F 0.00 PE 0.00 UN T 1.00 0.0000 PF 0.00 PT 50.86 ( 0) a I LIFEGUARD FIRE PROTECTION, INC. 2605 TEMPLE HEIGHTS DR. STE: F, OCEANSIDE, CA 92.056 (760) 806-9997 .. FAX (760) 806-4813 Hydraulic Design Information Sheet Name: La Costa Greens . . Date: 03/24/04 Location: 1925 Dove Lane Building: #8 . System No. 1-head Contractor. Lifeguard Fire Protection, Inc. Contract No. Calculated By: Lifeguard Fire Protection, Inc Drawing No. FP8 Construction: 0 Combustible 0 Non-Combustible Ceiling Height 8'-0" Ft. II NFPA 13: U Light Hazard Ordinary Hazard Group II 1 U 2 U 3 II Extra Hazard O NFPA 231 0 •NFPA 231C: Figure: Curve: O Other(Specify) Specific Ruling Residential Made By Date Area of Sprinkler Operation 1-head System.Type Density .10 0 Wet 0 Dry 0 Deluge 0 Pre-Action Area Per Sprinider 18'x 18' Sprinkler orNozzle Hose Allowance GPM: Inside 0 . Make Tyco Model LFII Hose Allowance GPM: Outside . Size 1/2" . K-Factor: 4.9 Rack Surinkler Allowance n/a Temnerature Ratum 155 SUMMARY GPM Required 17.68 PSI Required 31.73 At City Connection "C" Factor Used: Overhead 120 . Underground 150 WATER SUPPLY Water Flow Test Pump Data Tank or Reservoir Date & Time 10/17/03 10;45am, Rated Capacity n/a Capacity n/a Static PSI 72 At PSI n/a Elevation n/a Residual PSI 64 Elevation n/a GPM Flowing 1480 . Well Elevation 190' Proof Flow n/a GPM Location Point of connection at existing main in Dove Lane Source of Infonnatioti Carlsbad Fire Department COMMODITY STORAGE Commodity Class Location - Storage Height Area Aisle Width Storage Method: Solid Piled . % Palletized % Rack - Rack 0-Single Row 0 Conventional Pallet [J Double Row 0 Slave Pallet O Multiple Row 0 Open Flue Spacing In Inches Longitudinal . Transverse Horizontal Barriers Provided O Automatic Storage 0 Encapsulated O Solid Shelving 0 Non-Encapsulated Clearance From To of Storage to Ceiling Ft. In. Sigma Dynamic* Corporation 7700 Supply I Demand Graph V La Costa Greens Bldg #8 1-head cab SUBMITTAL SERIAL NO: 2932HY4 03-09-2002 PAGE 2 La Costa Greens Building #8 third floor 1-head calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Suttunary From To GPM IN Devices Ft PSI/Ft PSI 160 164 1.101 L 13.00 C=150 PT 13.02 (164) Q 17.68 F=DPV/2E F 11.00 PE 0.22 AO T 24.00 0.0542 PF 1.30 153 160 1.101 L 32.00 C=150 PT 14.54 (160) Q 17.68 F=E,DPV,2E/DPV,E F 22.00 PE 0.00 BNI T 54.00 0.0542 PP 2.93 PT 17.47 (153) ------------------ 150 151 1.101 L 1.75 C=150 PT 26.83 (151) Q 1.7.68 F=T/E: F 10.00 PR. 0.32 BN . T 11.75 0.0542 PF 0.64 PT 27.79 (150) ------------------- 5 4 . 7.758 L 174.00 C=:150 PT 24.02 ( 4) Q 6.06: F=0 F 0.00 PR 0.00 LU T 174.00 0.0000 PF 0.00 6 5 7.758. L 415.00 C=150 PT 24..02( 5.) Q 6. 06 F=GV, 2EE:/2EE F 60.40: PE: 0.00 LU T 475.40 0.0000 PP 0.00 7 •6 7.758 L 623.00 C=150 PT 24.02 C 6) Q 6.06 F=EE',GV/RE,GV,.2RE F 66.44. PE. 0.00 LU T 689.44 0.0000 PP 0.00 8 7 7.758 L; 22.0.00 C=150 PT 24.02 C 7) Q 6.06 F=GV F 6.04. PR 0.00 LU T 226.04 0.0000 PP 0.00 3. 8 7.758 L. 158.00 C=150: PT 24.02 ( 8) 6.06 F=GV,EEIGV,T F 78.57 PR 0.00 LU T 236.57 0.0000 PP 0.00 1 3 •7.758 . L 1.00 C=150 PT 24.02 C 3} Q 6.06 F=0 F 0.00 PR 0.00 LU T 1.00 0.0000 PF 0.00 PT 24.02 ( 1) 2 4 7.758 L 596.00 C=150 PT 24.0:2 ( 4) Q 11.62 F=T,GV,4EE/GV,2EE F 146.52 PE 0.00 LU T 742.52 0.0000 PP 0.00 1 2 . 7.758 L 1.00 C=150 PT 24.02 ( 2) Q 11.62 F=0 F 0.00 PE 0.00 LU T 1.00 0.0000 PF 0.00 PT 24.02 ( 1) SUBMITTAL SERIAL NO:2932HY4 . . 03-09-2002 PAGE 3 La Costa Greens - Building #8 third floor 1-head. calculation Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN . Devices Ft PSI/Ft PSI 152 153 ------------------ 1.101 L 10.00 C=150 PT 17.46 (153) Q 17.68 F=DPV F 1.00 PR 4.33 FRi T 11.00 0.0542 PP 0.60 151 152 1.101 L 9.00 C=150 PT 22.39 (152) Q 17.68 F=DPV F. 1.00 PR 3.90 • FRi T 10.00 0.0542 PF 0.54 PT 26.83 (151) 18 150 ------------------ 2.203 L 63.00 C=120 PT 27.79 (150) Q 17.68 F=T8E F 50.00 PR -0.87 FM T 113.00 0.0028 PF 0.32 17 18 2.203 L 63.00 C=120 PT 27.24 ( 18) Q 17.68 F=T/T F 23.20 PR 0.00 FM T 86.20 0.0028 PF 0.24 16 17 3.314 L 20.00 C=120 PT 27.48 C 17) Q 17.68 F=8E F 58.40 PR 0.87 FM T 78.40 0.0004 PF. 0.03 15 16 3.314 L 116.00 C=120 PT 28.38 C 16) Q 17.68 F=2EJT F 33.50 PR 0.00 FM . T 149.50 0.0004 PF 0.06 11 15 3.314 L 7.58 C=120 PT 28.44 1 15) Q 17.68 F=cV,E F 28.85 PE 3.28 FR T 36.43 0.0004 PF 0.01 10 11 4.280 L 7.00 C140 PT 31.73 ( 11) Q 17.68 F=E F 17.92 PR . 0.00 UN T 24.92 0.0001 PF 0.00 9 10 4.266 L 23.00 C=150 PT 31.73 C 10) Q 17.68 F=T F 38.42 PR 0.00 UN T 61.42 0.0001 PF 0.01 4 9 4.266 L 79.00 C=150 PT .31.74 ( 9) Q 17.68 F=T,GV,DDC/3E F 99.89 'PE -19.50 UN T 178.89 0.0001. PF 0.02 4" Watts 909 RPDA 11.77 ------------------ PT 12.26 ( 4) 0 1 7.758 L 1.00 Cr150 PT 24.02 ( V. Q 17.68 F=0 F 0.00 PE 0.00 UN T 1.00 0.0000 PP 0.00 PT 24.02 ( 0) r"-*1A7ER1,AL [DATA SUBMITTAL Lo Costa Greens Building iS - 125 Dove Lone Carlsbad, CA. LIFEGUARD FIRE PROTECTION, INC. 2(305 TEMPLE HEIGHTS DRIVE, STE. F OCEANSIDE, CA 92056 760-806-9997 • 760-806-413 FAX Protection Design & Consulting 2 D ' . W-'- M I. D.-D 4,o Exceptions LI With. Contm*nta -- N -J'.- A.) I Dite As o--5o2- ( 9 DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTION ua Patent No. 4,989.635 • U.S. Patent No.5,107,888 Physical Properties UA Patent Na 5,385,166 • U.S, Patent Na 56441 U.S. Fltont No. 5392803 • U.S Patent No.5503,178 Size of Mainline 2-1!?, 3, 6u, 8, & 10 Max. Working Pressure 175 PSI (1200 KPa) Hydrostatic Test Press. 350 PSI (2400 KPa) Temperature Range 32° F to 1400 F (00 C to 600 C) End Connections Flanged ANSI B16.1 Class 125 Materials Main Valve Body Ductile iron Grade 65-45-12 Coating Fusion epoxy coated Internal and external AWWA C550-90 MODEL 87eV DOUBLE CHECK DETECTOR (Shown In vertical position) Shut Off Valves OS & V resilient wedge gate valves AWWA C509 Trim Bronze Elastomer Discs EPDM Spring Stainless steel MODEL 876187ev DOUBLE CHECK DETECTOR Installation Views (Shown In standard orientation) Ir mn Suppoil ibhedbycu.tomei ulvewelgte . FLOW Standard orientation (Model 8760I876V) * Note-Model 876 does not include grooved end coupling. Recommended minimum clearances from permanent Structures br ease of testing and maintenance. Vertical orientation (Model 876V) 08 &Y Side View arnoved and Model 876V Model 876V Standard Orientation v&til Od.ataticn Note: The Model 876V is shipped in the standard (N-Shape) orientation as shown Dimensions Approximate El Net. OS&Y Os&Y Size A B C OPEN F G H J K M (Lbs.) 2'!? 12½ 204 241 I4 161e 16Io 611. 111!. 3'I 131. 271A 230 65 317.50 654.05 615.95 415.93 42228 158.75 292.10 88.90 346.08 692.15 104.33 12112 2514 241. 221k 161. 614 11½ 33/4 1411. 28½ 300 80 317.50 654.05 828.65 565.15 422.28 158.75 292.10 95.25 358.78 717.55 136.08 14 27716 26I. 23½ in. 7 13 41/2 102 31 330 100 355.60 708.03 679.45 590.55 450.85 177.80 330.20 114.30 393.70 787.40 149.69 6" 16 32'1. 321!. 301 1. 214ft 8 13 5112 181. 371/4 520 150 406.40 819.15 819.15 765.18 547.9 203.20 330.20 139.70 473.08 946.15 235.87 8" 18'I2 3711. 36318 373/4 2471. 9'!. 14'!. 6!. 2014 411 1. 860 200 469.90 952.50 923.93 958.85 631.80 234.95 368.30 171.45 527.05 1054.10 390.09 10" 21 42'!. 40/4 48 271!2 10 15 8 24 48 1460 250 533.40 1079.50 1035.05 1219.20 698.50 254.00 381.00 203.20 609.60 1219.20 662.24 Weights do not include risers or optional valve setter. Note: Dimensions shown are nominal. Allowances must be made for normal manufacturing tolerances. Refer to Specification Sheet SS VS for details on valve setter. FMSITEI Agency Compliance Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California. ASSE (Std. 1048) ANSI/AWWA (C510-89) CAN/CSA (B64.5) FM UL cUL * Less gate not FM approved. Less gate not UL listed unless Installed with UL listed gated valves. Application Non-Health Hazard Fire Sprinkler Systems Flow Orientation Standard orientation Is inlet flow vertical up, outlet flow vertical down. Vertical orientation is inlet and outlet flow vertical up. Options o Valve Setter with MJ x FL, MJ x MJ or FLxFL ends Model 876/876V Flow Curves -- _____ - I I II I II I II I II II .11 II I II II U 16 14 _____ .12 ____ 810 B 38 A 3,' 16 14 ,l2 10 A A 8" 0 25 75 125 175 225 275 325 GPM 0 500 1000 1500 2000 2500 3000 GPM 18 16 14 12 810 -j 88 2 4" 16 E'14 12 910 28 '86 24 2 - 10" Bi B 0 100 20) 300 400 500 600 700 GPM A-Vertical orientation (model 876V) B-Standard orientation (model 876) FEBCO Bacicflow Prevention P.O. Box 8070• From, CA 93747-8070 559 252-0791 Fax: 559 453-9030• www.cnpb4nd.com 8917SV 0141 oQ1MBIM0fleaInc. 0 1000 2000 3000 4000 5000 GPM The 6" and 10" flow curves in the standard orientation include the FEBCO valve setter model 611. CM lnitr1es, Inc. ISO 9001 Certified SchedulemlW/Schedulem400 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-1 0/Schedule-40 sprinkler pipe you get a UL listed and FM approved product Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (l"- 8") pipe and Sch-40 (1"- 2'4") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule- 10/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Sch-40 Specifications NPS Nominal I.D. Wt. Wt. (1120 Filled) PcsI WtJLlft (21') WtILIft (24') WI/Uft (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1W 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11/2" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 2W 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 3(iISpecifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ WVLlft (21') WI/lift (24') WI/lift (25') In; mm In; mm Lbs/Fl; Kg/m LbsIFt; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 1W 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 1W 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3' 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4° 4.260 5.610 11.18 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5' 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6 6.357 9.290 23.03 10 11951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets Hydrostatic Pressure Side Wall Rupture Vibration Test tqCo/Flow Control allied TUBE & CONDUIT @ <S> * 9 Listed Approved listed 16100 S. Lathrop. Harvey, IL 60426 Customer Service: 11350 Norcom Rd. Philadelphia, PA 19154 (800) 882-5543 2525 N. 27th Ave. Phoenix, AZ 85009 Fax 708-339-1806 S5-3 Super Flo/Dyna-Flow pipe is manufactured to meet ASTM A- 795 Type B, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/SuperFlo are UL Listed, FM Approved and TJLC Listed. (@ 0 CS Listed Approved Listed Super Flo/Dyna-Flow is UL/tJLC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Super Flo/Dyna-Flow is now available "hot-dip"galvanized and has been specifically approved by FM for dry systems uses. Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths Upon approval. - Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. 'Super Flo®/Dyna-Flow® .Aigh Strength Steel Pipe— The original high-strength Iightwa11 sprinkler pipe with hydraulics superior to Schedule-10. Product Nominal Wt/Ft 1Tnl-ri1[hl-- Wt,/Ft PCs/ Wt/Llft Wt/Lltt Wt/Lift NPS I.D. H20 Filled Lift 21' 24' 25' X i.' 1.191 0.830 1.31 91 1586 1812 1888 *25 30.3 1.2 1.95 91 719 822 856 11/4" 1.536 1.059 1.87 61 1356 1550 1615 32 39.0 1,6 2,78 61 615 703 733 x11/2" 1.728 1.667 2.71 61 2135 2440 2542 *40 43.9 2.5 4.03 61 968 1107 1153 X 2" 2.203 2.104 3.79 37 1634 1868 1946 *50 56.0 3.1 5.64 37 741 847 883 x 2 1/2" 2.703 2.564 5.10 30 1615 1846 1923 *65 68.7 3.8 7.59 30 733 837 872 x3" 3.314 3.387 7.18 19 1351 1544 1608 *80 84.2 5.0 10.69 19 613 700 729 x 4" 4.310 4.473 10.86 19 1784 2039 2124 *90 109.5 6.7 16.16 19 809 925 963 x6" 6.403 7.714 21.70 10 1620 1851 1928 *150 162.6 11.5 32,29 10 735 840 875 Super Flo/Dyna-Flow pipe is the "original" high-sLrength lightwall sprinkler pipe. Super Flo/Dyna-Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Super Flo/Dyna-Flow is a valuable addition to any fire protection system. Superior Hydraulics With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, SuperFlo/ Dyna-Flow pipe hydraulics are exceptional ' ger I.D.s enable SuperFlo/Dyna-Flow, Lid related components, to be down- sized within the system, thus increasing the potential for job cost savings. For complete Hazen-Williams charts, refer to "Super Flo/Dyna-Flow Hydraulic Data Tables." SuperPlo/Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is painrable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No .-'cial process or equipment are needed fabrication and installation. () allied TUBE & CONDUIT a p1.rnnue.az (DCAuMnr 16100 S. Lathrop 11350 Norcom Rd. 2525 N. 271h Ave. Customer Service: Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 1•800-797-6210 Fax 70S-339-1806 'Submittal Data Sheet Super 407Dyna-Thread Full Line Sch-40 Replacement Super .iO/Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Super 40/Dyna-Threads inside diameter is up to 3.6% larter than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe. down sizing often occurs. Super 40/Dyna-Thread IS hilly listed and approved UL. ULC, and FM for fire sprinkler applications. The life expectancy of Super 40/Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL (see CRR). The consistelu quality of steel to make Super 40/Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior Of Super 40/Dyna-Thread is protected by a clean, durable mill coating for extended iel1 life and easy paint application. With its increased strength and lighter weight, Super40I D iia-Tluaad reduces installation fat iue and is ideal for retro- flu applications. Corrosion Re'oMance Ratio CRRt is a UI. (Underwriters L:iboratory) term for the estimated life expectancy ol a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, a'sttmed to be the weakest point of the pipe length. Super 40/Dyna-Thread and Sch-40 have the .ame calculated wall thicknesses at this point and are both assigned the same CPR of 1.00. Comparison to L.W.T.Pipe More wall thickness at the thread (CRR= 1.00) gives Super 40/Dna-Thread better tire expectancy than lighuwall chreadable pipe joints. Unlike lithtwall tht'eiudiuble pipe. Super 40/Dyrta-Thread has no thread gauge warning. Super 40/ Dvna-Thread is approved for standard hanger spacing (15 ft. O.C), can be used as earthquake sway lracing. and is safe to use as drops. Super 40/Dyna-Thread is safer to weld on than many y,une-coaued lighiwall threadable pipe products. Super 40/Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Spèifications & Approvals Supei'4011)yna-Tht'ead pipe is mauLilacrured to meet: ASTM A 135. Grade A and is in compliance ith NFPA- 13. All sixes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dma-Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved fur use in wet sstems. Super 40/Dyna-Thread can tie "hot-dip" galvanized to meet FM requirement fur dry ysuems. Super 40/Dynu-Thread is approved (or all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). QDIL 0 @ UIod Approved Listed Stamp Here Product Nominal Wt/Ft Wt/Ft PCs/ Wt/Litt Wt/Lift Wt/Litt NPS 1. D. H20 Filled Lift 21' 24' 26' 1' 1.080 1.330 1.75 70 1955 2234 2327 *25 27.4 2.0 2.60 70 887 . 1013 1056 1 1/4" 1.408 1.870 2.54 51 2002 2288 2384 *3235.8 2.8 3.78 5190810381081 1 1/2" 1.639 2.290 3.22 44 2115 2418 2519 *4041.6 3.44.79 449591097 1143 2" 2.104 3.050 4.57 30 1921 2196 2287 *50 53.4 4.5 6.80 30 871 996 1037 Ainericin Thbe and Pipe was acquired by Allied Thbe and Conduit on February 1, 1997. The engineered lighrwall and standard wall family of prodttcls although they Wive dill'ereni names are the same in all respects with regard 10 strength, weight, bundle count, listings and approvals. For example, Dyna-Flow ail d Super Flu are hue same product as are Dynn Thread and Super 40. XL is mauiufncttured with Exterior galvanized coaling. BLT is manufactured with Black lacquer c'oatlng. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: Flow Data Friction Resistance The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221/2° elbow is approximately one-hall the resistance of a 450 elbow. Values of mid-sizes can be interpolated. Grooved IPS Fittings Victaulic fittings are designed specifically for use in grooved piping systems. Victaulic offers a broad line of fittings in sizes through 24 (600 mm) in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings ate 'supplied with grooves or shoulders to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to page 55 for fittings available for plain and applications). Fittings are provided in various materials including malleable iron, ductile iron, steel or segmentally welded steel depending on styles and size. Fittings re painted orange enamel with galvanized optionally available, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or with shoulders conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-FlangeO adapters, check disc clearance dimensions with I.D. dimension of fitting. Request 07.01. Alternate Materials Stainless Steel - Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 optionally available) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Request 17.04 for details Aluminum -Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 - 8" (25 - 200 mm). Request 21.03 or contact Victaulic for derails. Alternate Styles EndSeal® "ES" Fittings - EndSeal fittings are available in 2 - 12(50- 300 mm) for use with 'ES" grooved pipe and HP-70ES EndSeal or FiroRTh couplings. "ES" fittings are painted green for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fittings' when ordering. Request 07.04 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MEL) -For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may br inside diameter/end (abrasion resistance) or wrap-around (Corrosion and/or abrasion) machined. Request 25.03 or contact Victaulic for specific details. Pipe Pipe Inches/mm Equivalent Feet/meters 01 Straight Pipe Inches/mm Equivalent Feel/meters 01 Straight Pipe - - 90° Elbows 1 45° Elbows Tees 90° Elbows 451 Elbows Toes No.100 No. 110 No.100 No. 110 950 No.11 950 No. 10 No.10 950 No. 11 950 Noun. Actual Sid. Long Sid. Long Nom, Actual Std. Long Std. Long Size Size Radius Radius Radius Radius Branch Run Size Size Radius Radius Radius Radius Branch Run 1 1.315 1.7 - 0.8 - 4.2 1.7 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0 25 3 3. 7 0.5 . 0.7. . 13 0.5 150 1683 30 2.3 1.5 0.9 76 30 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 6.500 9.6 -. 5.0 - 25.0 10.0 50 60.3 1.1 08 05 0.3 26 11 6'1z* 1651 2.9 - 15 1.6 30 3t 3.000 4.3 -. 2.1 -. 10.8 4.3 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 76.1 1.3 - 07 .. 33 1.3 200 2191 4.0 3.0 2.0 1.2 101 40 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 80 68.9 15 12 08 0.5 40 1.5 250 273.0 52 3.7 2.5 1.5 i5 5.2 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 100 1143 21 16 tO 06 49 2.1 300 3239 6.1 4.4 30 18 15.2 61 4/4 4.250 6.4 - 3.2 - 15.3 6.4 14 14.000 # 23.0 #18.0 60.0 17.0 106.0 1.8 . 09 . 47 20 350 3556 ii 7.0 U 5.5 1113 5.2 5 125 5.563 ui1.3 8.5 2.6 - 4.2 -. 21.0 8.5 16 16.000 # 26.0 II 20.0 70.0 20.0 .. 1.3 -. 6.4 26 'iOU 4064 4 79 ii 6.1 213 61 51A.t 5.250 33.025 8.1 - 4.1 - 20.0 8.1 18 18.000 1 29.0 # 23.0 80,0 23.0 - - 1.5 6.2 2. 450 457.0 1 iF 8.6 1 1 0 24470 5½* 5.500 1397 8.5 2.6 - 4.2 -- 21.0 8.5 20 20.000 II 33.0 41 26.0 90.0 25.0 - 1.3 6.4 2.6 500 508.0 41 10.1 4 7.9 27.4 7.6 6 6.250 1 169.0 9.6 2.9 - - 5.0 15 -. 25.0 10.0 24 24.000 41 40.0 41 30.0 30.5 34.0 ft flnnIo,I Ii.'I'. ,Ih.. 5,,. .. . 76 20 600 6100 5 12.2 St 91 93 10.4 oe t 0.0, Dimension. 14 IFS GROOVED' CO.UPUNG'S Style 07 Zero-Flex® Rigid Coupling The unique angle-pad design of Zero-Flex® Style 07 adjusts to standard pipe and roll or cut groove tolerances, positively clamping the pipe to resist flexural and torsional loads. Wider key section tills more of the groove area. Request 06.02. Style 77 Standard Flexible Coupling Style 77 couplings are designed with cross-ribbed construction to provide a strong component for pressure piping systems. Sizes 3/4 -12° (20-300 nun) are two-piece housings. Sizes 14 - 22° (350 - 550 mm) are cast in four identical segments, with larger sizes cast in six segments. Request 06.04. 2- 12' Sizes Y-.------ .Z. 9 14- 16' Sizes 18- 24" Sizes ,0 0,7" I W. -12" Sizes 14- 22' Sizes worcss. Size W91Ech Dimensions - Inches/mm X V Z Inches/mm PSI/kPa Lbs./I,g '1 750 2.45 4.13 1.88 1.6 .41) Il 11/4 750 2.60 4.00 1.88 1.6 tili it)2 49 1½ 750 2.94 4.81 1.88 1.6 0 :,i,.m 2 'lii 750 3.19 5.44 1.88 2.3 m0 ,IN 11 .1)3 I 0 2½ 750 3.08 6.13 1.88 2.8 ;,i ,, 933 1543 49 1, 750 4.25 5.75 1.86 3.6 3 * 18 146 .&: 13 3 750 4.56 6.81 1.88 3.1 111 173 .40 1.1 4 750 5.81 8.25 2.06 4.6 1(0 :,I 1IL1 :'lI) 52 2 2 750 5.56 7.44 2.06 5.2 I-Il IltY 5 750 7.06 9.75 2.06 7.1 :' 700 6.36 9.18 2.06 7.4 74 '33 52 700 6.94 9.42 2.06 7.6 5½* 36 .39 6 700 8.00 10.75 2,06 8.7 1:,t) 203 52 614 1 700 7.85 10.18 2.06 9.2 4825 199 :1:9 5? 6%1: 700 8.00 oa 10.75 2.06 7.2 Z.:; ', 3'. 8 § 600 10.25 13.50 2.50 14.9 -1130 :'tio .3.15 10§ 500 12.86 16.75 2.56 25.0 2:14) .3410 .3" 'ti 6 12 § 400 14.88 18.50 2.56 28.2 .14)41 27'.0 _.4) I:') m3:3 14 300 16.19 19.75 2.94 32.8 .Ini .'Lk;I 411 NY 75 14 16 300 19.38 21.75 2.94 41.2 .1(11) 2(I(371 .lt :1:3.3 .I 14) 7 18 300 20.69 23.88 3.06 54.2 ie :.'oot ,?ti doS 75 24 20 300 23.00 27.38 3.06 67.2 tltl ?0435 :194 (33):, 78 JO 5 24 250 27.13 31.50 3.13 76.2 NO 172:1 0133) 2130 79 34 C. U.U. Dimension. • Hater to notes on page 7. § Available to J.I.S. dimension. Nom* Si Max. Wotkpess. Dimensions - Inches/morn WgIEflch X V Z Inches/mm PSI'/kPa Lbs/kg 3/4 1,000 2.13 3.63 1.75 - 1.1 1 - 1.000 2.38 3.88 1.75 -. 1.3 69U11 lit.) 09 'II 419 1¼ 1,000 2.63 4.63 1.75 - 2.0 32 4391)1) d' 118 -1.4 09 1½ 1.000 3.00 5.00 1.75 - 2.1 41 6WO 1. I-I 1 2 1,000 3.63 5.63 1.75 - 2.6 69Oi 92 143 (I I 21/2 1.000 4.25 6.25 1.75 3.1 3900 109 1541 3 * 1.000 4.31 6.31 1.75 3.6 11900 10 Ii,t) I-I 1 43 3 1,000 5.00 7.00 1.75 3.5 Lit) tillilO 123 1 .14 1 t 31h 1,000 5.63 8.00 1.75 5.6 01) t3900 143 21i.3 1.1 '3' 4 1.000 6.38 8.50 2.00 - 6.6 90 4(143(1 1132 .31t1 NI :t ii 1 1.000 5.88 6.06 2.06 - 7.0 09431) 1.49 5 1.000 7.63 10.25 2.00 10.6 2:1 (i90 1) 13)4 _'tiO hl -1 U 1,000 7.34 9.20 2.06 - 100 14313 .73.4 .1'I 1 1,000 7.60 9.44 2.06 - 11.0 ,191)31 1433 'Ii) :2 m) 6 1,000 9.00 11.50 2.00 - '11.8 61)390 1?9 29.1 91 :. -1 51,4 6900 1,000 8.50 10.38 2.06 - 13.2 2 Ili 143.1 :'' (1 (1 61/2 1,000 9.19 11.50 2.06 13.2 )04) 2:13 .92 :'2 d 11 8 § 800 11.38 14.50 2.38 20.1 1100 1;)w 23311 3439 (30 )I I 10§ 800 13.50 16.75 2.50 - 28.3 :s1'431) 34.1 4115 43.4 11' 11 12 § 800 15.50 19.00 2.50 34.2 .1434 1113 i;) IN : 14 300 16.63 20.00 2.88 35.6 3:10 oLi5 4.1:1 SIM .3 itt I 15 300 17.88 21.25 2.88 - 48.8 3:343:; 1 .154 16 300 19.00 22.38 2.88 - 51.1 .1434' .'(n3' .133 18 300 21.25 24.38 3.13 - 64.4 -453 304)3; z,44' Sill 20 300 23.50 27.50 3.13 - 91.2 3'04) 706:i ,3) - (it))) i) 1 11 I 22 300 25.63 30.00 3.13 - 92.0 5,110 _106 43:11 73) 417 24 - 250 27.63 31.38 3.13 - 94.0 hOt) 172'1 703' O.D. Dimension. lløler to notes on page 7. § Available to JJ.S. dimension. N. Size Range - 1/4 thru 1-1/2 inch rod in 10'-0" lengths. Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain, Electro-Galvanized, and Stainless Steel. Order By - Figure number, rod diameter, and finish. MAX. REC. LOAD LBS. APPROX. ROD FOR SERVICE TEMPS WEIGHT SIZE 650°F 750°F PER 100 FT. 1/4 240 215 12 3I 1/2 1130 1010 .53 3/4 2710 2420 123 1 4960 4420 222 'tL 1.1/2 11630 10370 510 T 1110L OTC 0 INCORPORATED CORONA. CA • (909) 737-6599 53 FIG. 99 ALL THREAD ROD CUT TO LENGTH Size Range - 3/8 thru 7/8 inch rod in 1 inch increments. Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain, Electro-Galvanized, and Stainless Steel, Order By - Figure number, rod diameter, rod length, and finish. ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMPS. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 FIG. 100 ALL THREAD ROD FULL. LENGTHS C A OL O•____ INCOflPOtiATP CORONA. CA • (909) 737.5599 15 FIG. 2 ADJUSTABLE RING HANGER FIG. 2 NFPA ADJUSTABLE RING HANGER WITH REDUCED ROD SIZE Size Range - 1/2 thru 6 inch pipe. Material - Carbon Steel, Mu. Galvanized to G-90 specification. Function - For general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Spring tension on swivel nut holds it securely in hanger before installation. Swivel nut easily removed. Approvals - Underwriters' Laboratories tisted and Factory Mutual Engineering approved. Conforms to Federal Specification WW.H.171E, type 10, and Manufacturers Standardization Society SP-69, type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized and Stainless Steel. Order By - Figure number and pipe size. PIPE ROD STOCK MAX, REC. APPROX. WEIGHT PER 100 FIG. 2 SIZE SIZE A B C SIZE LOAD LBS. FIG. 2 NFPA 1/2 3/8 3-1/8 2.5/8 1.3/8 169axi , 400 17 17 1 3/8 3-3/8 2-5/8 1-1/8 16gax1 400 18 18 1-1/2 3/8 3-7/8 2.7/8 1 169ax1 400 21 21 2-1/2 1/2* 5-3/4 4-1/4 1-5/8 149ax1-3/16 600 41 40 3 600 Q UX 3-1/2 1/2* 7-3/8 5-1/4 2-1/8 14a>1-3/16 600 52 50 4 5/* 1000 X-1-1/4 1250 97 95 8/4 .9 3/8 1/ , l2a 14/4 1250 139 '.\h, 3/8" nut is used when NFPA rod 5i2in9 is requested. 6 1/2" nut is used when NFPA rod sizing is requested, To LTC D INCORPORATED 1.20 CORONA. CA • (909) 7-5599 FIG. 1000 "FAST CLAMP" SWAY BRACE ATTACHMENT Size Range - Pipe size to be braced: 1" through 8" Sch. 10 and 40. Pipe size used for bracing: 1" and 1-1/4" Sch. 40 IPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment com- ponent of a sway brace system: Fig. 1000 is used in conjunction with a Tolco 900 Series Fitting and joined together with bracing pipe per NFPA #13*, forming a complete sway brace assembly. Features - Can be used to brace Schedules 10 and 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector that necessary minimum torque (5 lb/ft) has been achieved. Application Note - Fast Clamp need not be field assembled. Position Fast Clamp and tighten two hex nuts until leaf spring flattens, *Length of bracing pipe per National Fire Protection Association, Pamphlet #13, paragraph A-3-10.3.5: 1" Schedule 40 bracing pipe maximum 7'-2". 1-314" Schedule 40 bracing pipe maximum 9'-2". Approvals - Underwriters' Laboratories listed. Note - Must be used with Tolco U.L. Listed 900 Series attachment. Finish - Plain, Electro-Galvanized, HDG, and Stainless Steel. Order By - Order first by pipe size to be braced followed by pipe size used for bracing, figure number, and finish. - I, ------ ------- I C UID To &LC 0 INCORPORATED 118 CORONA. CA • (909) 7375599 FIG. 910 SWIVEL SWAY BRACE FITTING Size Range 1 & 1.1/4 inch bracing pipe, Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbances. The building attachment component of a sway brace system; The Fig. 910 is used in conjunction with the Fig. 1000 "Fast Clamp" (or with a Fig. 4A Pipe Clamp), and joined together with a brace pipe per NFPA #13*. Features - Universal swivel design allows Fig. 910 to be attached at any surface angle. All steel construction eliminates deficiencies associated with casting type attachments. Application Note - *Length of bracing pipe per National Fire Protection Association Pamphlet #13, paragraph A-3-10.3,5: 1" Schedule 40 bracing pipe maximum 7-2". 1-1/4" Schedule 40 bracing pipe maximum 9'-2". Approvals - Underwriters' Laboratories listed. Note -The Fig, 910 Swivel Attachment and the Fig. 1000 "Fast Clamp" (or Fig. 4A Pipe Clamp), make up a sway brace system of U.L. Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA). Finish - Plain, EleotrQ-a1vanized, and Stainless Steel. Order By - Figure number, pipe size, and finish. Note - Specific weight load conditions may require more than one fastener to the building structure. Sway brace attachments may be ordered with D ii' gas tt~li D A? r1oL SIZE A B WiC SIZE E F PER 100 1 2 1-1/2 3 9/16 2-5/16 2 88 /4Ls/16..•:..i5/l4'...3•..9/16.25/l....2.5/161 :. ••.• V BRECCO Brecco Corporation GAUGES GAUGES -r p FOR USE WITH WET OR DRY SYSTEMS. GAUGES HAVE A BRONZE BURBON TUBE MOVEMENT IN A STAINLESS STEEL PLATED CASE (UNLESS OTHERWISE NOTED). 3-1/2" DIAMETER. U.L. AND F.M. APPROVED (UNLESS OTHERWISE NOTED). Pan No. Description BO*CaéI GAAWSS350 AIR / WATER 0 - 300 psi -60 - WI STAINLESS STEEL CASE GMSS250 AIR W/ RETARD 250 PSI 3-1/2" DIA. WI STAINLESS STEEL 60 CASE GAWP200 2" RESIDENTIAL GAUGE 300 PSI (NOT UI. OR F.M. APPROVED) 100 GMWP350 AIR (WATER W/ PLASTIC CASE 60 i.8OO543.4 194 Fax: 1.8774749248 AR" = AS REQUIRED breccocarp@earthiink.net 082000 TOLCO INCORPORATED CORONA. CA • (909) 737-5599 4]. FIG. 51 AND FIG. 52 SIDE BEAM BRACKETS (CONT.) I E FIG. 51 FIG. 52 FIG. 51 for NFPA Rod and Fastener Sizing APPROX. PIPE ROD HOLE SIZE STOCK WEIGHT SIZE SIZE A B C H-I H-2 SIZE PER 100 1/2-2 3/8 2 3/4 2 7/16 7/16 3/16x2 35 l/4 qj 2 3/4 9/6 7/16 3/16x2 I 5-6 1/2 2-1/2 3/4 2-1/2 9/16 9/16 3/8x2-1/2x2.1/2 , • 71 g4/2.9Ji6 3/x2 /x2 1/21 7Q I FIG. 52 - 6 Hole Bracket ROD HOLE SIZE STOCK H-3 SIZE 3/8x1/2 2 1-1/16 2 9/16 7/16 9/32 3/16x2 35 FIG. 56 TAPPED SIDE BEAM CONNECTOR Size Range - 1/2 thru 4 inch pipe (3/8 inch rod). Material- Carbon Steel Function - Practical and economical bracket used 11 to support hangers from steel or wood beams. Can be used with concrete shot-type inserts. Tapped hole allows easy adjustment of hanger rod. Approvals - Underwriters' Laboratories listed and Factory Mutual Engineering approved for 1/2 - 4" pipe. Finish - Plain, Electro-Galvanized, HDG, and Stainless Steel. Order By - Figure number and finish. Note -Per NFPA #13: 1/2 thru 2 inch pipe use 3/8 inch fastener; 2-1/2 thru 4 inch pipe use 1/2 inch fastener. G A H F !D ~ C, ROD APPROX. PIPE SIZE HOLE SIZE STOCK WEIGHT SIZE A B C D E F G H J SIZE PER 100 1/2 -4 2-5/8 3/8 1 3/8 1-1/16 1-1/8 7/16 9/16 1-1/4 1/4x1 20 tqco /Fire & Building I Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series LFII Residential Pendent Sprinklers 49 K-factor Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010/(800) 877-1295 General Description The Series LFII (TY2234) Residential Pendent Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. When aesthet- ics and optimized flow characteristics are the major consideration, the Series LFII (TY2234) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY2234) has a 4.9 (70,6) K-factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (TY2234) is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Es- cutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceil- ing position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY2234) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. WARNINGS The Series LF!l (TY2234) Residential Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Sprinkler/Model Identification Number SIN TY2234 Technical Data Approvals: UL and C-UL Listed. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.9 GPM/ps11'2 (70,6 LPM/barl/2) Temperature Rating: 155°F/680C or 1750F1790C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame .............Brass Button .............Bronze Sealing Assembly . .......... Beryllium Nickel w/Teflont Bulb .........3 mm dia. Glass Compression Screw .....Bronze Deflector ...........Bronze Ejection Spring . . . Stainless Steel fDuPont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Page 1 of 8 JANUARY, 2003 TFP400 Page 2 of 8 TFP400 Minimum Flow (b) and Minimum Flow (b) and Minimum Flow (b) and Maximum Maximum Residual Pressure Residual Pressure Residual Pressure Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Area (a) Ft. (Max. 2 inch Rise (Greater Than 2 Inch Rise (Greater Than 4 inch Rise Ft. x Ft. (m) for 12 Inch Run) Up To Max. 4 Inch Rise for 12 inch Run) Up To Max. 8 inch Rise for 12 inch Run) (m x m) 155"F168°C or 155°F168°C 175'F179°C 155°F168°C 175'F179°C 175°F1790C 12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 16 GPM (66,1 LPM) (3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.6 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar) 14 x 14 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) (4,3 x 4,3) (4,3) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar) 16 x 16 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0,48 bar) 13.5 psi (0,93 bar) 18 x 18 18 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 23 GPM (87,1 LPM) (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 22.0 psi (1,52 bar) 20 x 20 20 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 21 GPM (79,5 LPM) N/A (6,1 x 6,1) (6,1) 16.7 psi (1,15 bar) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-tactor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS Design Criteria The Series LFII (TY2234) Residential Pendent Sprinklers are UL and C-UL Listed for installation in accordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the localAuthority having Juris- diction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as speci- fied in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. A minimum discharge ofo.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed with a deflector to ceiling distance of 1-3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2. NOTE So as to help avoid obstructions to water distribution, a maximum 12 inch deflector-to-ceiling distance is permit- ted for NFPA 130 and NFPA 13R ap- plications where the sprinklers are lo- cated in closets. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Beam Ceiling Design Criteria The Series LFll (1Y2234) Residential Pendent Sprinklers are UL and C-UL Listed for installation in residential oc- cupancies with horizontal ceilings (i.e., slopes up to a 2 inch rise over a 12 inch run) with beams when installed in ac- cordance with the following criteria: General Information. The basic con- cept of this protection scheme is to locate the sprinklers on the underside of the beams, Ref. Figure 5, (not in the beam pockets); to identify the main beams that principally run in one direc- tion as "primary beams"; and, to iden- tify the beams that run principally per- pendicular to the main beams, as may be present (or in some cases may be necessary for proper sprinkler protec- tion), as "secondary beams". Primary and Secondary Beam Types. Solid surface, solid or hollow core, combustible or non-combustible. Primary and Secondary Beam Posi- tioning. Directly attached to the un- derside of a combustible or non-com- bustible smooth ceiling at any elevation. Primary Beam Cross-Section: Maxi- mum depth of 14 inches and the maxi- mum width is unlimited.The cross-sec- tional shape of the primary beam may be rectangular to circular. 2-7/8 DIA. - (73,0 mm) 7/16±1/8' 1/2(12,7mm) r (11.1±3.2mm) 2-1/4'DIA. I 1/4(6.4mm) FACE OF mm) I SPRINKLER [57.2 MOUNTING I FITTING PLATE t \ MOUNTING 1/8' SURFACE/ (3,2 mm) / 1-3/8' (34,9 mm)f CLOSURE TY2234 1-1/8' (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY2234) RESIDENTIAL PENDENT SPRINKLER TFP400 Page 3 of 8 Components: 1 - Frame Button Sealing Assembly Bulb 5 - Compression Screw Deflector * Ejection Spring * Temperature rating is indicated on 6 Deflector. 7/16(11,1 mm) 1/2 ESCUTCHEON NOMINAL N PT PLATE SEATING MAKE-IN SURFACE 2-1/4 , 7/t f (57,2 mm) 7 1-5/8 (41.3 mm) e I WRENCH - \\W) STYLE 20 FLATS RECESSED E SC UTC H EO N CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 SERIES LFII (TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS Secondary Beam Cross-Section. Maximum depth to be no greater than the primary beam and the maximum width is unlimited. The cross-sectional shape of the secondary beam may be rectangular to circular. Primary Beam Spacing. The primary beams (Fig. 6A) are to be 3 ft. -4 in. to 6 ft. from the compartment wall to cen- ter of the nearest beam and from cen- ter to center between beams. Secondary Beam Spacing. The sec- ondary beams principally run perpen- dicular to the primary beams. Secondary beams of a depth equal to the primary beam must be placed so that the beam pockets created by the primary beams do not exceed 20 feet in length (Fig. 613). NOTE When the beam pockets created by the primary beams exceed 20 feet in I ength, the installation will require the use of secondary beams as described above. Otherwise, secondary beams need not be present. Secondary beams of a cross-sectional depth greater than one-quarter the depth of the primary beams are to be a minimum of 3 ft. - 4 in. from the - WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH compartment wall to center of the nearest beam and from center to cen- ter between beams (Fig. 6C). Secondary beams of a cross-sectional depth no greater than one-quarter the depth of the primary beams may be placed at any compartment wall to center of the nearest beam distance iii/// WRENCH RECESS (END A USED FOR 1Y2234) FIGURE 3 W- TYPE 6 SPRINKLER WRENCH Page 4 of 8 TFP400 and from any center to center distance between beams (Fig. 6C). Lintels. Lintels over doorways exiting the compartment must be present. The minimum height for the lintels is 8 inches or no less than the depth of the Primary Beams, whichever is greater. Sprinkler Types. Series LFII (TY2234), 155F and 175F, Pendent and Recessed Pendent Residential Sprinklers. Sprinkler Coverage Area and Hy- draulic Design. The sprinkler cover- age areas and hydraulic design criteria as presented in the Table A for "Hori- zontal Ceilings" are to be applied. Sprinkler Position. The deflector to bottom of primary beams for the Series LFll (TY2234) Pendent Sprinklers or Series LFII (TY2234) Recessed Pen- dent Sprinklers is to be 1-1/4 to 1-3/4 inches (Fig. 5A). The vertical center- line of the Series LFII (TY2234) Pen- dent Sprinklers is to be no greater than half the primary beam cross-sectional width plus 2 inches from the centerline of the primary beam (Fig 5B). NOTES Core drilling of beams to allow the in- stallation of sprinkler drops requires consulting with a structural engineer. Where core drilling is not permitted, the previously stated sprinkler position criteria for the Series LFll (TY2234) Pendent Sprinklers allows for the sprinkler drop to be placed adjacent to the primary beam. Beam and Soffit Arrangements. A soffit is permitted to be placed around the perimeter of a compartment with the beam arrangement within the sot- fited area (Fig.7). The cross-section of the soffit may be any size as long as it does not create an obstruction to water distribution per the obstruction rules of NFPA 13 for residential sprinklers. When soffits are present, the pre- viously provided 3 ft. - 4 in. to 6 ft. "compartment wall to adjacent beam" distance for the primary and secon- dary beams is to be measured from the face of the soffit as opposed to the compartment wall. NOTE Although the distance to the beams is measured from the face of the soffit, the sprinkler coverage area is to be measured from the compartment wall. Installation The Series LFll (1Y2234) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6mm). A leak tight 1/2 inch NPTsprink!er joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Pendent sprinklers are to be installed in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series LFII Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. Recessed pendent sprinklers are to be installed in the pendent posi- tion with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- A Lq 1Y2234 B Lq MAXIMUM 1Y2234 ONE-HALF BEAM - WIDTH PLUS 2' (50,8 mm) FIGURE 5 SPRINKLER POSITIONING UNDER PRIMARY BEAMS (Refer to the "Beam Ceiling Design Criteria" section) plied, slide on the Style 20 Closure over the Series LFll Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 ALLFIGURES: I"—A - - A - - A DISTANCES ARE MEASURED TO COMPARTMENT WALL FACES AND TO CENTERLINES OF BEAMS PRIMARY BEAM Page 5 of 8 14" (356 mm) MAXIMUM A= 3-4" to 6-0" (LO to 1.8 m) FOR PRIMARY BEAMS HAy- INGA 14" (356 mm) MAXIMUM DEPTH 20'-0"(6.1 m) MAXIMUM COMPARTMENT WALLS SECONDARY BEAM PRIMARY BEAM FIGURE 6A PRIMARY BEAM SPANS UP TO 20-0 (6.1 m) AIAI.A — k ) B A3'-4" to 6-0" (1.0 to 1,8 m) FOR PRIMARY BEAMS HAV- ING A 14' (356 mm) MAXIMUM DEPTH B = 20-0" (6.1 m) MAXIMUM FOR SECONDARY BEAMS THAT ARE TO BE EQUAL IN DEPTH TO PRIMARY BEAMS AND THAT MUST BE IN PLACE SO THAT PRIMARY BEAM POCKETS DO NOT EXCEED 20'-0"(6.1 m) COMPARTMENT WALLS FIGURE 6B PRIMARY BEAM SPANS GREATER THAN 20-0" (6.1 m) SECONDARY BEAM * PRIMARY BEAM *REFER TO FIGURE 6B COMPARTMENT FOR SPANS WALLS EXCEEDING 20'-0"(6.1 m) A_ -. A IF F —_I 3-4' to 6-0' (1.0 to 1.8 m) FOR PRIMARY BEAMS HAV- ING A 14" (356mm) MAXIMUM DEPTH C = 3-4"(1.0 m) MINIMUM FOR SECONDARY BEAMS HAVING DEPTHS GREATER THAN 25% OF PRIMARY BEAMS —or— C =ANY DISTANCE FOR SEC- ONDARY BEAMS HAVING DEPTHS UP TO 25% OF PRIMARY BEAMS FIGURE 6C COMBINATIONS OF PRIMARY AND SECONDARY BEAMS FIGURE 6 BEAM ARRANGEMENTS (Refer to the "Beam Ceiling Design Criteria" section) Page 6of8 TFP400 Care and Maintenance The Series LFII (TY2234) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. TFP400 Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability.. Sprinkler Assembly: Series LFll (1Y2234), K=4.9, Residen- tial Pendent Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155°F/68'C or Chrome Plated .........P/N 51-201-9-155 155'F168°C White Polyester ........P/N 51-201-4-155 155'F168°C Natural Brass ..........P/N 51-201-1-155 175'F/79°C or Chrome Plated .........P/N 51-201-9-175 175°F/79C White Polyester ........P/N 51-201-4-175 175F/79'C Natural Brass ----------P/N 51-201-1-175 Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify) finish, P/N (specify). 1/2' (15 mm) Style 20 Chrome Plated ---------P/N 56-705-9-010 1/2' (15 mm) Style 20 White Color Coated ---------------P/N 56-705-4-010 1/2' (15 mm) Style 20 Bright Brass Coated ---------------P/N 56-705-2-010 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Page 8 of 8 TFP400 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCO /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 oem Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010/(800) 877-1295 Series TYFRB - 28, 42, 56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of The National Fire Pro- tection Association, in addition to The standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.8K, 1/2"NPT TY2131 - Upright 4.2K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 3/4NPT 1Y4231 - Pendent 8.0K, 314'NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Ij L A. :• Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi1/2 (40,3 LPM/barl'2) K = 4.2 GPM/psi1/2 (60,5 LPM/barll2) K = 5.6 GPM/p5i112 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/bar1/) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflonf Bulb ..............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze 1- Page 1 of 8 APRIL, 2003 TFPI7I STYLE 10or20 RECESSED ESCUTCHEON SSP DEFLECTOR * PENDENT Page 2 of 8 ESCUTCHEON 7116'(11,1 mm) PLATE SEATING 1/2 ** NOMINAL SURFACE N MAKE-IN PT T_ T 2-1/4 (57,2 mm) L 'WRENCH FLATS 2-7/8" (73,0 mm) DIA. RECESSED PENDENT TFPI7I SSU * DEFLECTOR 6 I 7/l& (11,1mm) I 4 NOMINAL I MAKE-IN 2 2-3/16" 3 (55,6 mm) 1/2' NPT** 1 7 UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYI131) AND PENDENT(TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 100r20 PLATE SEATING 1/2" ** NOMINAL RECESSED SSU* SURFACE MAKE-IN ESCUTCHEON NPT DEFLECTOR 7/16" 2-3/16" 1,1 mm) _______ NOMINAL (55,6 mm) _____ 6* MAKE-IN 1-1 2-3 WREN( 1 (55,6 mm) SSP DEFLECTOR* L 2-7/8" (73,0 mm) DIA. 1/2 NPT** FLATS (38,1 mm) - PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT 77 7/16 (11,1 mm) 1/2' ** NOMINAL NPT MAKE-IN -j--_ Ii I TFPI7I ESCUTCHEON PLATE SEATING SURFACE T_ - 2-3/16" \ (55,6 mm) 1-1/2" (38,1 mm) SSP DEFLECTOR * Page 3 of 8 STYLE 10or20 RECESSED ESCUTCHEON DEFLECTOR 1 MAKE-IN 2-3/16 : WRENCH - ( " FLATS ; 7/16' NOMINAL I (11,1 mm) I 55,6 mm) 6* 1/2' NPT** 2-7/8' (73,0 mm) DIA PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **pp thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES. TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2(12,7 mm) PLATE SEATING NOMINAL SURFACE NPT MAKE-IN 2-5/16" (58,7 mm) I I SSPDEFLECTOR* 2 PENDENT REC STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR _I 6* 1/2' 1 (12,7 mm) I NOMINAL I : 4 MAKE-IN 2-1/4' 57,2 mm) ( -, 3/4 NPT" t UPRIGHT CROSS SECTION WRENCH FLATS -7/8" (73,0 mm) DIA. ESSED PENDENT 1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Page 4 of 8 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE""" IPOLYESTER 2.8 1/2' PENDENT (TY1231) and UPRIGHT (TY1131) 135"F/57°C Orange 1, 2, 3, 5 155"F/68"C Red 175°F/79°C Yellow 200"F/93°C Green 286"F/141°C Blue NPT RECESSED PENDENT (TY2231)" Figure 5 1350F/57°C Orange 1, 2, 5 155°F/68°C Red 175" F/79°C Yellow 200°F/93°C Green RECESSED PENDENT (TY2231)'" Figure 6 135°F/57°C Orange 155"F/68"C Red 175"F179"C Yellow 200°F193°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY3131) 135"F/57"C Orange 1,2 155"F/68"C Red 175"F/79"C Yellow 200"F/93°C Green 286"F/141°C Blue RECESSED PENDENT (TY2231)" Figure 7 135°F/57°C Orange 155"F/68"C Red 175"F/79"C Yellow 200"F/93"C Green RECESSED PENDENT (TY2231)"" Figure 8 135"F/57"C Orange 155°F168°C Red 175"F/79"C Yellow 200°F/93"C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10 (1/2' NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Re- cessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2' Total Adjustment Re- cessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or There is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 inch (2,4 mm) for the 286°F/141 °C temperature ratings. A leak tight 1/2 inch NPTsprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40, 7Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TV-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the TFPI7I Page 5 of 8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED WHITE" I POLYESTER LEAD COATED 5.6 1/2° PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1, 2,3,4,5,6 1,2,3,5 155°F/681C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY3231)° Figure 9 135°F/57°C Orange 1,2,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED PENDENT PENDENT Figure 10 135°F/57°C Orange 1,2,3,4,5 1,2,4,5 N/A 155°F/68°C — Red 175°F/79°C Yellow 200°F/93°C Green 8.0 3/4° PEN DENT and UPRIGHT (TY4131) 135°F/57°C Orange 1, 2,3,4, 5,6 1,2,5 155°F/68°C (TY4231)' Red 175°17/791C Yellow 200°F193°C Green 286°F/141°C Blue NPT 135°F/570C Green 1,2, 4, 5 N/A RECESSED PENDENT (TY4231)° Figure 11 155°F/681C Orange 175°F/79°C Red 200°F/93°C Yellow RECESSED PENDENT (TY4231)°° Figure 12 135°F/57°C Orange 1,2,3,4,5 N/A 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB) as Quick Response Sprinklers; however, the LPC does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31.53-428-3377). Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2' NPT) or Style 40 (3/4' NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4° NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND &O K-FACTOR SPRINKLERS sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Page 6 of 8 2-7/8 DIA. - 5/8±1/4" (73.0 mm) I 314"(19.1 mm) (15.9±6.4 mm) - 2-1/4" DIA. I 1/4(6.4mm) I FACE OF MOUNTING PLATE I FITTING 1/8" %\mm I SPRINKLER I frn) MOUNTING SURFACE/ CLOSURE SERIES 1-5/16" (33.3 mm) TY-FRB 13/16" (20.6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 5/6±1/4" (73.0mm) I 3/4"(19.1 mm) (15.9±6.4 mm) 2-1/4" DIA. I 1/4"(6.4 mm) I MOU FACE OF NTING I PLAT SPRINKLER E FITTING 1/8 MOUNTING SURFACE/ CLOSURE SERIES 1-1/4(31.8mm) TY-FRB 3/4" (19.1 mm) FIGURE 7 SERIES TV-MB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I - 2-7/8" DIA. - ( 1/2±1/8 73.0 mm) I 1/2'(12.7 mm) r (12.7±3.2 mm) 2-1/4" DIA. 1/4(6.4mm) I FACE OF MOUNTING PLATE I FITTING I 1/8" f mm) SPRINKLER I (3.2 mm) MOUNTING/ 1-5/16 (33.3 mm) CLOSURE SERIES TY-FRB 1-1/16(27.0mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. (73.0 mm) I 1/2±1/8" 1/2'(12.7 mm) r (12.7±3.2 mm) 2-1/4 DIA. J 1/4(6.4mm) I I FACE OF MOUNTING I (572mm) PLATE I I SPRINKLER 17-11 I FITTING 1/8__ j 3jmm) I \ MOUNTING SURFACE SERIES 1-1/4 (31.8 mm) I CLOSURE TY-FRB 1 (25.4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFPI7I 2-7/8' DIA. - 5/8±1/4 (73.0 mm) I 3/4(19.1 mm) (15.9±6.4 mm) - 2-1/4' DIA. 1/4(6.4mm) I FACE OF I MOUNTING (572 SPRINKLER PLATE FITTING MOUNTING SURFACE/ I SERIES 1-1/4(31.8mm) I CLOSURE TY-FRB 314"(19.1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. - 5/8±1/4' (73.0 mm) I 314!'(19.1 mm) I (15.9±6.4 mm) - 2-1/4' DIA. I 1/4(6.4mm) I (57.2 MOUNTING FACE OF SPRINKLE4R1 PLATE FITTING 32mm) MOUNTN SURFACE CLOSURE SERIES . 1-5/16'(33.3mm) TY-FRB 13116'(20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 7 of 8 2-7/8" DIA. 1/2±1/8' I (73.0 mm) 1/2"(12,7 mm) r (12.7±32 mm) 2-1/4' DIA. I 1/4' (6.4 mm) I FACE OF I MOUNTING I SPRINKLER I PLATE I FITTING 1/8' (3.2 mm) f \ MOUNTING SURFACE SERIES 1-1/4(31.8mm) CLOSURE TYFRB 1"(25.4mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. 1/2±1/8' (73,0 mm) 1/2"(12.7 mm) r (12.7±32 mm) 2-1/4" DIA. 1/4(6.4mm) FACE OF (57.2 mm) MOUNTING I SPRINKLER PLATE I FITTING 1/8' (3.2 mm) MOUNTING t \ SURFACE / CLOSURE SERIES 1-5/16" (33.3 mm)f I TYFRB 1-1/16" (27.0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON &0 K-FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. WRENCH RECESS (END "A' USED FOR 1/2' NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4' NPT MODELS) FIGURE 13 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH Page 8 of 8 TFPI7I P/N 57 - XXX - X - XXX I L I MODEL/SIN 330 2.8K UPRIGHT (1/2°NPT) TY1131 331 2.8K PENDENT (1/2°NPT) TY1231 340 4,2K UPRIGHT (1/2°NPT) TY2131 341 4.2K PENDENT (1/2°NPT) 1Y2231 370 5.6K UPRIGHT (1/2NPT) 1Y3131 371 5.6K PENDENT (1/2°NPT) 1Y3231 390 8.0K UPRIGHT (3/4NPT) TY4131 391 8.0K PENDENT (314°NPT) TY4231 I I 155 175 200 286 RATING L 135 SPRINKLER 1 NATURAL BRASS 155°F/68°C 4 WHITE POLYESTER 175°F179°C 9 CHROME PLATED 200°F/93°C 7 LEAD COATED 1 286F/141°C TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY-IS 013, 747,317- 1:17-L-11MAE TMAN Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/20 (15 mm) Style 10 Chrome Plated .........P/N 56.701-9-010 1/2° (15 mm) Style 10 White Color Coated ................P/N 56-701-4-010 1/2° (15 mm) Style 10 Brass Plated ...........P/N 56-701-2-010 1/2 (15 mm) Style 20 Chrome Plated .........P/N 56-705-9-010 1/2° (15 mm) Style 20 White Color Coated ----------------P/N 56-705-4-010 1/2 (15 mm) Style 20 Brass Plated ...........PIN 56-705-2-010 3/4'P(20 mm) Style 30 Chrome Plated .........P/N 56-705-9-011 3/4° (20 mm) Style 30 White Color Coated ................P/N 56-705-4-011 3/4° (20 mm) Style 30 Brass Plated -----------P/N 56-705-2-011 3/4° (20 mm) Style 40 Chrome Plated .........P/N 56-700-9-010 3/40 (20 mm) Style 40 White Color Coated ----------------P/N 56-700-4-010 3/4° (20 mm) Style 40 Brass Plated -----------P/N 56-700-2-010 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqco Flow' / lControl I Products BlazeMaster' FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET Two FIRE PRODUCTS 451 North Cannon Avenue Lansdale Pennsylvania 19446 wwwtyco-fir.com TEChNICaL SERVICES TEL (800) 381-9312' FAX (800) 791-5500 E.nw tachsene@tycofp.com I No. 19-1.5 TDU5 4-1.1.20 9/2001 Tee Part No. Size Sch. 1/0 Wt. 80000 3/40 40 '/" 0.11 lb. 80001 40 3/Il 0.19 lb. 80002 1'/4" 40 '/." 0.26 lb. 80003 1 1'/2 80 1" 0.51 lb. 80004 80 1/," 0.90 lb. 80005 21/211 80 1'/ 1.59 lb. 80006 80 lu/i, 2.41 lb. 'Part' 'No. I Size Sch. T/O ______ I Wt. lb. I 1 In/i," I 2 1 [80015 1"x 3/0 1 1 40 If/I," 10.281 Cross Part No. Size Sch. 1/0 Wt. 80009 3/411 40 '/" 0.13 lb. 80010 40 "I,," 0.23 lb. 80011 1'I4" 40 "/n" 0.34 lb. 80012 11/2" 80 1',,," 0.67 lb. 80013 80 1/," 1.00 lb. 80014 21/2" 80 ,11 1.91 lb. 80008 80 V 3Iis" 2.89 lb. Reducing Cross '' f se ceo e . Qfl $ £$ç4yco$i e Prtducts (TFP) BlazeMaster CPVC pipe and pn.*e filterf heat resistance and fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping automatic fire sprinkler systems. They are made from a materials used in the plumbing trade. Various adapters are specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping. All female post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability. the art additives. TFP BiazeMaster CPVC products are Grooved adapters connect directly to grooved end valves easier to install than traditional steel pipe systems, and at and metallic pipe, with flexible grooved end couplings. Technical Data Sizes: 3/44 - 3 /41-3 Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDFt 135 MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and Note: See wnentTFP BlazeMester Installation lnstnicllons and ASTM F439 (Sch. 80) Tediniral Manual, brext lislirig/appiwal information Colon Orange Pipe Nom.Pipo Size Avg. O.D. liches Avg. I.D. inches WI. ths./Ft. WI. 110 hUed Pipe Us.fft. R. of Pipe per Lilt Wt. per LIft Lbs. 3/0 1.050 0.874 0.17 0.43 7875 1413 V. 1.315 1.101 0.26 0.67 5040 1320 1.660 1.394 0.42 1.07 2835 1191 1.900 1.598 0.55 1.40 2205 1136 2.375 2.003 1 0.86 220 1 1260 1063 2 '/2' 2.875 12.423 1.26 3.22 1215 1531 3.500 1 2.952 1.87 4.79 720 1344 Fillings 450 Elbow TsO -. Reducing ._. . 900 Elbow 90° Elbow Part No. Size Sch. 1/0 Wt. 80050 3/41 40 3/,1 0.08 lb. 80051 40 W 0.11 lb. 80052 -- 1114" 40 - 3/4" 0.20 lb. 80053 1'/2" 80 7/,," 0.31 lb. 80054 80 3/i" 0.56 lb. 80055 2/21 80 3/" 0.89 lb. 80056 1 80 1" 11.19 lb. I Part1 I No. I Size I ISch.l I I 1/0 l Wt.I I I l lb.I Ii 12 180032 1" x 3/411 40 I it/ 13/ 0.161 Part No. Size Sch. I 1/0 Wt. 80025 3/41 40 '/i " 0.09 lb. 80026 40. 340 0.14 lb. 80027 11/41 40 '/" 0.21 lb. 80028 11/2" 80 V/i," 0:40 lb. 80029 80 11/4° 0.79 lb. 80030 21/2" 80 11/211 1.14 lb. 80031 311 80 1W,, 1.82 lb. Coupling Part No. Size 5th. 1/0 I Wt. 80200 x 3/0 40 'lie" 10.04 lb. 80201 11/4" x 3/0 40 'Ii." 0.11 lb. 80202 Pl" x 1" 40 '/,," 0.12 lb. 80203 11/2" x 3/40 80 '/." 0.16 lb. 80204 11/2"x 1" 80 1/211 0.14 1b. 80205 11/20 X 1'I4" 80 3/0 0.17 1b. 80206 x 3/4" 80 3/411 0.27 1b. 80207 2"x 1" 80 "Vi." 0.26 lb. 80208 2" x 1'/4" 80 9/,," 0.24 lb. 80209 2"x 11/2" 80 1 '/16" 0.19 lb. 80215 The x 1" 80 1"/i." 0.42 lb. 80214 21/2" x 1/" 80 1/4" 0.45 lb. 80213 21I" X 11/" 80 161611 0:46 1b. 80211 21/2".x 20 80 1'!,," 0.29 lb. 80210 311 x 2" 80 2/i," 0.72 lb. 80212 311 x 21/211 80 111/is" 0.47 lb. Reducing ,l Tee 4T,0L?T,v T/O T/O -fil rn_Ca b!'- Reducer -Bushing Part Nol Size Sch. T/O I Wt. 80075 3/40 40 1 /311 0.07 1b. 80076 1" 40 '4" 0.11 lb. 80077 11/40 40 3/30 0.12 1b. 80078 11/20 80 9M' 0.25 1b. 80079 20 80 3f'" 0.38 lb. 80080 21/20 80 /,e" 0.87 1b. 80081 30 80 3/," 0.91 1b. T/O Grooved Coupling -. _.-. PipiO.O. Adapter ___-_J I Part No. Size Sch. T/O Wt. Pipe CD 80160 11I4" x 11/4° Grooved 40 2 6/,," 0.78 lb. 11/4" (1.660') 80161 11/2" x 1'/2" Grooved 80 2 '/1 0.95 lb. 11/20 (1.900") 80162 20 x 2" Grooved 80 2 still" 1.42 lb. (2.375") 80163 21/20 x 2'/a" Grooved 80 2 /I6" 2.28 lb. 2½" (2.875") 80164 3 x 3" Grooved 80 2V4" 3.00 lb. 1 (3.500") 80168 3" x 76.1 mm Grooved 80 21/4" 2.72 lb. 76.1mm (3.000") Part No. Size Sch. T/O Wt. 80100 3/ 4 11 40 /,." 0.04 1b. 80101 1" 40 3/h1 0.06 1b. 80102 11/4" 40 1/2" 0.10 lb. 80103 11/20 80 she 0.20 1b. 80104 20 80 'I." 0.31 lb. 80105 21/" 80 7/0 0.58 lb. 80106 3" 80 1" 0.88 lb. It 1/0 Female -. Adapter Part No. Size Sch. 1/0 Wt. 80142 3/4 x 2/4' NPT 40 '4" 0.41 lb. 80145 x 1" NPT 40 3/4" 0.63 lb. 80146 11/4" X 11/4" NPT 40 W' 1.03 lb. 80147 11/a" X 11/2" NPT 80 1" 1.42 lb. 80148 x 2" NPT 80 1/e" 2.66 lb. I/O Male -- Adapter Part No. Size I Sch. 1/0 I Wt. 80157 x /" NPT 40 1'/ia" 0.33 lb. 80158 1" x 10 NPT 1 40 1 1I," 1 0.56 lb. T/O Reducing .....- Coupling Part No.1 Size I Sch. T/0 Wt. [ 80220 1" x 3/0 40 1 '/." 0.08 lb. Part No. Size - Sch. 1/0 Wt lb. 11 2 3 80132 3/0 x 3/40 x 1" 40 3/" 3/Il 3/0 0.14 80133 1 1, x /" x 3/ 4 11 40 /2" /16" /4" 0.14 80134 1" x 3/4"x 1" 40 3/0 I 5/1 3/0 0.17, 80260 1"x 111 X 8/4" 40 3/4" 3/40 /16 0.16 80135 11/4" x 1" x 3/4"40 1/16" 3/ 4 0 13/,,0 0.21 80136 11/4"x 1" X 1" 40 1/I6" 5/0 "ho"022 80137 11/4" x 1" x 11/4" 40 I3/," 13/1611 I3/30 0.26 80261 11/411 x 11/411 x 3/ 4 0 40 '/," 6/s" /." 0.23 80262 11/40 X 11/4" x 1" 40 3/411 3/411 7/," 0.26 80138 11/4" X 11/41 X 11/2" 80 10 1" 80 140 V/a" x 11/40 x 3/ 4 11 80 1/2ll 5/Il 1" 0.36 80141 V/a" x 11/40 x 10 80 1/2ll 3/lI 1 '/.1 0.38 80263 1'/2" X 1'/2" x she 80 '/16" /I6" 1" 0.36 80264 11/2" X 11/2" x 1" 80 6/160 /t." - 10 0.38 80275 11/2" x V/a' x 11/4" 80 7/60 'I." 1" 0.45 80265 2" x 2" x 3/0 80 3/0 5/Il 1/" 061 80266 2" x 2" x 1" 80 7/0 7/0 15/el 0.66 80274 2" x 2" x 11/40 80 1" 1" 13/sI 0.74 80267 2" x 2" X 11/2" 80 11/8" 11/so 1/," 0.78 80271 21I2" x 21I2" x 10 80 111/is" lhh/,,00 19/i. 1.43 80272 21/2" x 21/" X 11/411 80 lu/isO 111/,511 10/i." 1.46 80273 21I2" x 21/," x V/a" 80 111/is" 111/1.11 15/1611 148 802761 x The x 2" 80 1"/,s" 1'Vie" 16/1s 1.50 80270 3" x 3"x 11/2" 80 1/4 1/4" 1/,." 12.28 80268 3"x Tx 2" 80 1/4" 1/4" 1/4" 2.25 80269 3" x 3" x 21h" 80 1/4" 13/40 115/is 2.44 Sprinkler Head Adapter with Brass Threaded Insert Ej6 Part No. Size Sch. T/O Wt. 80175E 3/40 x 'I? NPT 80 7/,.° 0.20 lb. 80176E 1"x /2" NPT 80 0.22 lb. 80177WL 8/40 x 1/2" NPT 40 9/,0 0.16 lb. 80179 1 x 3/40 NPT 40 3/40 0.43 lb. Sprinkler Head Adapter (Spigot) with Brass Threaded Insert LJ!I Part No. Size Sch. I/O Wt. 80177L. 3/40 x 1/30 NPT 1 40 1/2 0.161b. 80178 1" x /2° NPT 40 1/2" 0.20 lb. Sprinkler Head Adapter with Brass Threaded Insert 4 Part No. Size Sch. T/O Wt. 80175W 3/40 X Va" NPT 40 7/,0 0.19 lb. 80176W 1"x 'Ia" NPT 40 7/,0 0.18 lb. Part No. Size Sch. I/O Wt. lb. 1 2 80462 1" x 1" x Va" NPT x 'k' NPT 40 6/0 1'/s" 1 0.46 80463 1"x 1"x '/° NPT X /2" NPT 40 WT 7/7.9 0.47 Back-to-Back Cross with Brass Threaded Insert Sprinkler Head Adapter 90° Elbow with Brass Threaded Insert Back-to-Back Tee with Brass Threaded Insert Part• No. Size Sch. I/O Wt. lb. 1 2 80199 3/40 X 'I? NPT 40 s/s" Is/is" 0.20 80189 1° x 'Ia" NPT 40 I3f 1/,s° 0.26 Sprinkler Head Adapter _± with Brass Threaded Insert I TIO' III Tic! Part No. Size Sch. I/O I Wt. lb. 1 T-2-1 80459 10 x 'Ia" NPT X 'Ia" NPT 40 hI/91 15h."I 0.48 80460 1" x 1/20 NPT x 'Ia" NPT 40 "Its' I 1'/.° 1 0.46 Part No. Size Sch. T/O Wt. lb. T 80250 3/4"X 3/4"X /2" NPT 40 i/a" 9/6" 1" 0.22 80251 x 1" x I/s" NPT 40 "1,." I3/" 0.29 80249 1"x 1° X 1" NPT 40 'Ii" I6/," 1I,," 0.73 80256 11/4" X 1" X 1/2" NPT 40 7/,," '/i." We" 0.30 80252 11/4" X 11/4 X /2 NPT 40 7/0 7/," VI," 0.31 80257 11/2" X 11/4 X 'Ia" NPT 80 'It," "I," 1/is" 0.43 80254 11/2" X VIa" x 'Ia" NPT 80 '/t " /,," l'I,," 0.46 80258 x 11I2° X /2 NPT 80 1/20 5/,0 16/9 0.56 80253 2° x 2° x I/an NPT 80 1/ Llmfted Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects In material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Product.. No warranty Is given for products or Components manufactured by companies not affiliated by ownership with Tyco Fire Product, or for products and components which have been subject to alms. improper installation, corrosion, or which have not been Installed, malntaln.d, modified or repaired In accordance with applicable Standards of the National Fir. Protection Association (NFPA). andlor the standard, of any other Authorities Having Jurisdiction. Material, found by Tyco Fir. Product, to be defective shall be either repaired or replaced, at Tyco Fire Products usia option. Tyce Fire Products neither assumes, nor authorizes any person to assume for It any other obligation in connection with the sale of producte or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design error. or Inaccurate or Incomplete Information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE. IN CONTRACT. TORT. STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL. INDIRECT. SPECIAL OR CONSEQUENTIAL DAMAGEL INCLUDING BUT NOT LIMITED TO LABOR CHARGES. REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREClOINCi WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. tqc0//70w C~ntwl Wft ?yoM0814?M0# 1ML5 VT8 xd x.tw'to ..LlX1.M8tOjt.. d MoMO? ç5 Oct 17 03 12:32p LIFEGUARDFIRE 7600064813 P. 1 AS0509A /Vfioi~ tie )- 1'x LIFEGUARD FIRE PROTECTION, INC. Fire Protection Design & Installation AAA October 17, 2003 Mr. Gregory Ryan Carlsbad Fire Department 1635 Faraday Avenue Carlsbad, CA 92008 Fax (760) 602-8561 Re: La Costa Greens Carlsbad, CA The following are results from a fire flow test perfonned for the proposed La Costa Greens Multi-Family Development in Carlsbad, CA. The test was conducted by Lifeguard Fire Protection, Inc. and witnessed by the Carlsbad Fire Department. The test was conducted on hydrants located on Dove Lane, between El Camino Real and B Street. The results are as follows: Date: October 17, 2003 Time: 10:15AM Static: 72 psi Residual: 64 psi Pitot: 78 psi Port: 2 /2" Flow: 1480 gpm Hydrant C: .90 Please call if you have any questions. Respectfully, M*Lll~ Darien Moran Lifeguard Fire Protection, Inc. 2605 TEMPLE HEIGHTS DRIVE A SUITE F A OCEANSIDE, CA 92056 A 760/806.9997 A FAX 760/806.4813