Loading...
HomeMy WebLinkAbout6200 AVENIDA ENCINAS; ; FA100060City of Carlsbad Fire Alarm Permit Permit No: FAI00060 6200 AVENIDA Job Address: ENCINAS Permit Type: FALARM Parcel No: Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 9/29/2010. Approved: 9/29/2010 Issued: 9/29/2010 Inspector: Project Title: ENCINA WASTEWATER TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: Owner: SIMPLEX GRINNELL 3568 RUFFIN ROAD SAN DIEGO CA 858-633-9100 Fees ($) Add'I Fees ($) Total ($) . Balance ($) 130 • 0 . 130 0 Encina Wastewater Authority Encina Fire Protection System Expansion Upgrade Dryer Building Submittal Package FILE COPY Fire Alarm 16721-001 Prime Contractor Southern Contracting Company 559 N. Twin Oaks Valley Rd. San Marcos, CA 92069 Ph: 760-744-0760 Fax: 760-744-6475 Submitting Contractor Southern Contracting Co. 559 N. Twin Oaks Valley Rd. San Marcos, CA 92069 Attn: Joe Teti Ph: 760-744-0760 Fx: 760-744-6475 SCC PREPARER'S COMMENTS Fire Alarm Submittal No. 16721 - 001 This submittal includes manufacturers catalog data sheets for materials specified in the products section. To facilitate the submittal process, one (1) manufacturers data sheet is submitted herewith for approval of the specified grade of product. Where multiple manufacturers (or equal) are specified, the specified and approved grade of product will be provided. Installation of the materials submitted herewith will be in compliance with the applicable sections, Part 3 - Execution. e Tyco Fire & SimplexGrinnell Security SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www. Sirnplexgrinnell. corn FIRE ALARM SYSTEM ITEM MODEL NO. DESCRIPTION C.S.F.M. NO. A B C IC E F G H J K 4010-9101 4010 FACP (EXISTING) 2081-9272 BATTERY 6.2AH (EXISTING) 4906-9101 STROBE, MULTI-CD WALL 4906-9104 STROBE, MULTI-CD CEILING 4906-9127 HORN-STROBE, MULTI-CD WALL 4906-9130 HORN-STROBE, MULTI-CD CEILING 4099-9003 PULL STATION, DOUBLE ACTION 4098-9792 SSD SENSOR BASE 4098-9714 SMOKE SENSOR 4098-9733 HEAT SENSOR 4905-9815 SYNC ADAPTOR HRK OUTDOOR HORN ELECTRICAL MATERIAL PVC COATED CONDUIT, ELBOWS, COUPLINGS, ,. CONDUIT FS/FD/FSD(GANG BOXES), PRT27 (CONDUIT BODIES), LB FORM 8 (CONDUIT BODIES), STRAPS AND CLAMPS, (PLASTIBOND-OCAL) STAINLESS STRUT SYSTEM, CLAMPS AND STEEL - FASTENERS (COOPER B-LINE) STRUT SYSTEM ANCHORING ANCHOR BOLTS (HILTI) 7170-0026:226 N/A 7125-0026:316 7125-0026:316 7125-0026:317 7125-0026:317 7150-0026:224 7300-0026:217 7272-0026:218 7270-0026:216 7300-0026:315 7135-1653:189 . Simplex T rueAlarm® Fire Alarm Controls UL, ULC Listed; FM, CSFM, Model 4010 Fire Alarm Control Panel for TrueAlarm and MEA (NYC) Approved* Analog Sensors and IDNetTm Addressable Devices Ilutt* Standard features include: Up to 250 addressable TrueAlarm sensor or addressable device points using mNet communications that operate with either shielded or unshielded twisted pair wiring** Four, 2 A notification appliance circuits (NACs) with solid state current protection Internal event reporting DACT module (standard on models 4010-9101, 4010-9102, & 4010-9150) UL listed to Standard 884 Installation convenience features: Power-limited design with electronic modules contained on one-piece chassis Up-front terminal blocks for wiring access Compact NBMA I rated cabinet is available in beige or red and can be pre-shipped for early installation Setup, programming, and maintenance features: Device level ground fault search, locate and isolate Auto Program for general alarm operation TrueAlarm individual analog sensing with front panel information and selection access "Dirty' TrucAlarm sensor maintenance alerts, service and status reports including "almost dirty" Default TrueAlarm sensor device type operation Duplicate address error detection Front panel or PC programming TrueAlarm sensor peak value performance report WALKTESTTM silent or audible system testt Software verification simulation mode Supports the following IDNot devices: Addressable manual stations Quad-state zone adapter modules (ZAMs) for initiating device monitoring iDNet ground fault/short circuit isolator base for TrueAlarm sensors Quad-state line powered individual addressable modules (lAMs) for initiating device monitoring and relay control Available option modules include: Door mounted 24 LED annunciator (std. on ULC models) Network, or Point Reporting DAd' Class A NAC adapter module RS-232 ports for printer and maintenance PC Additional power supply; Auxiliary Relay Module or City interface Equipment for Suppression Release Applications (refer to data sheet S4010-0003) Compatible with Simplex5 auxiliary panels: TrucAlcria Addressable Controllers and NAC power extenders (IDNet controlled and conventional) 4003 Voice Control Panel 4081 Battery Cabinet with charger for 50 Ab batteries 4010 Fire Alarm Control Panel (with standard door) Dscrintic TrueAlarm fire alarm control panels have the ability to provide location accuracy for monitoring and control. When equipped with TrueAlarm analog sensing for smoke and heat detection, the processing power of the control panel also has the ability to analyze conditions at each location to provide accurate detection with significantly reduced maintenance costs. The 4010 TrucAlarm Fire Alarm Control Panel has been specifically designed to provide addressable operation and analog detection in a cost-effective package for application sizes that previously were considered only appropriate for conventional zoned monitoring. Installation and Service Ease. The 4010 mounts on a single chassis for quick installation and removal. Terminal blocks arc large and Lip-front for easy access and inspection. Optional modules are easily and quickly installed and programmed as required. The 4010 cabinet provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting. Smooth cabinet surfaces are provided for locally cutting conduit entrance holes exactly where required. 4010 cabinets and electronics can be ordered separately, allowing early cabinet installation. Ground Fault Assistance. Ground fault problems often occur during installation. The 4010 provides isolating circuitry and software-controlled sequencing to isolate ground faults to specific identi fled locations. This assistance helps the installer to accurately locate the wiring problem for quicker repair. Rellor to page 6 for Heling details. We produd has bean approved by the Callimnle Stole Fire Marshal (CSFM) preounnt to Section 13144.1 of the California Health and $afety Coda See CSFM Usllng7170O02&228 for albe values anWor conditions concernirg materiel presented in this docuaenL It is sahecl to m-emniaotion, revision, and possible cancellation. Accepted for use -Cityof Now York oepajtnrent eleoItengs-MEA35.93E Additional Itsthgs may be applicable; contact your local Simplex product supplier for tire latest status. Listings and approvals under Simplex Time RecoiclerCo. are the property of Tyca Safety Products Westminster. Rallomonelcg smoke detection and IDNet addressable devices are protected by one OF more of the fotiovtng U.S. Patents: 5,155,468; 5.173.683; M777.6,400.0114; 5.552755 5,552,783; DES. 377.460. t WAI.KFEST system testis protected under U.S. patentS 4,725,818. S4010-0001-9 10/2004 ITEM A LIk [111Th .1Z' 11 i'm 'ci Extensive Feature List. The 4010 Fire Alarm Control Panel provides access to an extensive feature list that includes: Providing easy and powerful operator information with a logical, menu-driven display Extensive and automatic diagnostics for maintenance reduction History Logs available from the LCD or capable of (optionally) being printed Software Verification, allowing detailed logic programming simulation to be conducted without activating connected outputs Control Panel (or service PC) label editing Password access control Auto Program Quick Configuration (Quick-CFIG) of conncctcd modules and IDNet devices for general alarm operation to quickly get the system up and running Convenient Status Information. With the locking door closed, a window allows viewing of the status display. The 4010 status panel provides a two line by 40 character, super-twist LCD information display and eight status LED indicators as shown in the illustration below. From this display, the LED indicators will describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door will provide access to the control switches and allow further inquiry by scrolling the display for additional detail. (Refer to control panel functional illustration below.) WALKTEST Diagnostic Operation Mode. The patented WALKTEST process allows a single person to perform system test. The system records test inputs such as intentional alarms or trouble and either logs the response (silent WALKTEST operation) or outputs a brief, recognizable audible notification signal (audible WALKTEST operation). Extended Operator Control Panel Functions - FIVE STATUS INDICATOR LEDs provide system status Indications in athlion to LCD information. LEDs flash to indicate the condition and than when acknowledged, remain on until reset 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 40 characters for custom label information FIRST ALARM DISPLAY: Operation can be selected for maintained display of first simm until actinowledoed THREE PROGRAMMABLE LEDs provide custom labeling (labels insert into a podcet), the top two LEDs are selectable as red or yellow, the bottom LED is selectable as green or yellow Man 1 SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge and silences the operator panel and all annunciator tone-alerts SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, and silences the operator panel and all annunctetortone.a?erts \ 1NINE EXTENDED FUNCTION KEYS (accessible with \ door open) select and scroll through display prompts for \ locating additional system information, performing \ maintenance functions, or for front panel programming ALARM SILENCE causes audible notification appliances lobe silenced, used after evacuation is complete and while alarm source is being investigated TROUBLE ACK acknowledges system inoubles, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts S4010-0001-9 1012004 ITEM A Overview. The 4010 provides IDNet addressable device communications. Using a two wire circuit, individual devices such as manual fire alarm stations, TrueAlarm sensors, and sprinkler waterfiow switches can be directly connected (or interfaced) to the IDNet controller to communicate their identity and status. This addrcssability, allows the location and condition of the connected device to be displayed on the 40 10 panel LCD and on system annunciators. Additionally, control circuits (fans, dampers, etc.) may be individually controlled by using a relay ]AM (individual addressable module). The 4009 IDNet NAC Extender or the TrueAlert Addressable controller can be controlled for local or remote notification appliance expansion. (Refer to individual device documentation for further details.) Capacity. A total of 250 addressable monitor and control points may be intermixed on the same pair of wires. By using Zone Adaptor Modules (ZAMs) or Individual Addressable Modules (lAMs), conventional initiating devices can be connected to the IDNet circuit. IDNet Addressable Operation. The IDNet controller continuously interrogates each addressable device on the communication channel for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Sophisticated poll and response communication techniques ensure supervision integrity and allow lbr "T-tapping" of the circuit for Clasi B (Style 4) operation. Wiring Requirements. Refer to the specifications chart below. Distances are for shielded or unshielded wire. Shielded wire may provide protection from unexpected sources of interference and may be required for some applications. Wiring Specifications Size 18 AWG minimum Preferred Wire Shielded twisted pair (SIP) Unshielded twisted pair (UTP) Acceptable Farthest Distance turn Control Up to 2500 feet (762 m) Panel to Device Total Wire Length Allmed With Up to 10,000k (3 km). T Taps for Class B Wiring TrueAlarm System Operation. IDNet communications are used for TrueAlami smoke and temperature sensors. Every four seconds, smoke sensors transmit an output value based on their smoke chamber condition. The 4010 CPU maintains a current value, peak value, and an average value of each sensor's output. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Programmable Sensitivity. The sensitivity of each sensor can be field programmed at the 4010 Control Panel for different levels of smoke obscuration (in percent) or for specific heat detection levels, in order to evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read and compared to the alarm threshold directly in percent. .3 10 r1 KunvIrIrrrs]iwtIiiThWJ11r'DI TrueAlarm heat sensors can be selected for rate-of-rise detection as either 15° F (8.3° C) or 200 F (11.10 C) per minute with an independent fixed limit of 135° F (57° C) or 155° F (68° C). TrueAlarm heat sensors can also be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155 F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. To additional IDNet devices, up to 250 total ModularTrueAlann TrueAlert Addressable Coniroler sensor with base Supervised PAM Modular TrueAlarm sensor i- will, I)t4et Isolator base Addressable station I.. 4009 IDNel MAC Extender Quick-Connect Monitor ZAte and TrueAlerm sensor Relay tAMe 4010 Fire Nanii Control Panel with . annunciator door •. :.. 4010 Control Panel with Typical IDNet Devices iir.:il[si.'wtiirtI .nEmIarw1ribtJ TrueAlarm operation gives the 4010 system the ability to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 (National Fire Alarm Code) requirement for a test of the sensitivity range of the sensors is fulfilled by the TrueAlarm ability to maintain the sensitivity level of each sensor. Modular TrueAlarm sensors use the same base and different sensor types (photoelectric smoke sensor, or heat sensor) can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. 84010-0001-9 10/2004 ITEM A TrueAlarrn Information Details True Alarm sensor data can be displayed on the system LCD, on a remote maintenance PC, or printed on a remote printer. With the proper operator access, a TrueAlarm Service Report can be generated to list the specific details of each TrueAlarm device. This report, as well as the Status Report can either be displayed on the remote maintenance PC or captured permanently by using a remote 80 character printer. The report samples below illustrate the format provided on either the remote maintenance PC or a printer. This information is available at the system LCD by identifying the specific point of interest and reading one point at a time. Model 4190-9013 is a UL Standard 864 listed 80 column, 24 pin dot matrix printer (refer to data sheet S4190-001 I). (Model 2190-9039, a 24 VDC, 40 column printer, is compatible with the 4010 for event printing only. Refer to data sheet S2190-0014.) Printer (Simplex model 4190-9013) Local computer .t. 4010 Fire Alarm \ One connection type per 4010. Control Panel selected by module choice; max. t-&i wiring distance Is 300 ft (91 m) @9600baud - ' Remote authorized maintenance computer connected via dial-up Service Modem Connection RS-232 connection Options (refer to module selection on page 6) TrueAlarm Status and Service Report Samples Simplex 4010 Fire Alarm System Page 1 REPORT 3 TrueAlarm Status Report 2:43:03 pm Mon 18-Oct-04 Zone Sensi- Almost Name Custom Label tivity Device Status Dirty Ml-1 ANALOG PHOTO CLEAN ROOM 0.5 % NORMAL M1-2 ANALOG ION CLEAN ROOM 1.3 % NORMAL M1-3 ANALOG PHOTO MAIN LOBBY 2.5 % NORMAL M1-4 ANALOG PHOTO CONFERENCE ROOM 1 2.5 % NORMAL M1-10 HEAT DETECTOR GARAGE 135 F NORMAL MI-11 ANALOG PHOTO KITCHEN 3.7 % NORMAL *YES* END OF REPORT Typical TrueAlarm Status Report Information Printout and/or Maintenance PC Screen Simplex 4010 Fire Alarm System Page 1 REPORT 4 : TrueAlarm Service Report 2:56:09 pm Mon 18-Oct-04 0ev Alarm Avg Current! Peak/ State Hum Custom Label at: val % alarm % alarm 1 ANALOG PHOTO - CLEAN ROOM 0.5/ 83 67 68/ 1% 72/ 10% NOR 2 ANALOG ION - CLEAN ROOM 1.3/209 94 97/ 2% 101/ 1% NOR 3 ANALOG PHOTO - MAIN LOBBY 2.5/185 117 117/ 0% 125/ 42% NOR 4 ANALOG PHOTO - CONFERENCE ROOM 1 2.5/161 93 93/ 0% 93/ 0% NOR 10 HEAT DETECTOR - GARAGE 135F/253 -- 631-671 66/ 69F NOR ii ANALOG PHOTO - KITCHEN 3.7/216 116 116! 1% 110/ 36% NOR END OF REPORT Typical TrueAlarm Service Report Information Printout and/or Maintenance PC Screen 4 - 84010-0001-9 10/2004 ITEM A N2 Communications for Serial Annunciator Control. Control for up to 6 remote Simplex Annunciator products including 24 Point 110 Module, and LCD Annunciator. Includes extensive troubleshooting diagnostics. Access Port. RS-232 service port for connecting PC tools for service diagnostics and for programming the CPU Flash EPROM memory. iDNet Addressable Communications Channel. Addressable channel provides communications for up to 250 remote addressable devices, including TrueAlarm analog sensors and isolator bases (see descriptions on page 3). Four NACs. Class B output is standard, rated for 2 A® 24 VDC nominal, with solid state current protection. Class A operation is optional with the addition of an adapter module. NAC operation can be selected for "on-until-Silence" or "on-until-Reset," and can be Temporal pattern, 20 or 120 bpm March Time pattern, or continuous. Each NAC is also individually selectable to control Simplex synchronized visible notification appliances and to control audible notification appliances using SmartSyncTM control, allowing separate audible and visible appliance operation using a common 2-wire circuit. (Class A, Style Z, SinartSync circuits require SmartSync Control Module 4905-9938, refer to data sheet S4903-0010 for details.) Two Auxiliary Output Circuits. Operation is programmable for trouble, alann, supervisory, or other fire response functions. Output is one Form "C" dry contact each, rated 2 A® 24 VDC. An optional relay kit is available for switching up to 1/2 A at 120 VAC. Power Supply. Standard output is 4 A @28 VDC, filtered, non-regulated. Internal system power is provided separately, allowing the 4 A to be available for NAC and auxiliary power tap functions. Over-current protection is solid state and self-resetting. Auxiliary Power Tap. Provides up to 1(2 A of the standard power supply voltage, over-current protected. Battery Charger. Capable of charging up to 25 Ah sealed lead-acid batteries (40 10 cabinet mounted). A recharge time of 24 hours is typical with stable 120 VAC input. For applications requiring larger batteries, external charger/cabinet assemblies are available. A depleted battery cutout feature is programmable to advise and/or to reduce current when battery voltage is low. (The 4010 is available with a Simplex Network interface. 4010 points can be declared "public.") Network Interface, Fixed Media. Available for wired applications. Network Interface, Modular Media. Available for wired connections or fiber optic. Require separate media modules. May be both wired, both fiber optic, or one of each. DACT, Point Reporting Module. Provides serial output information that can send location details to a remote receiving station. DAd, Event Reporting Module. For applications where simple event status information is required (Alarm, Trouble, Supervisory, and AC power failure). Dual RS-232 Module. Available for interfacing to a printer and a maintenance PC. Single RS-232 Module with Service Modem Connection. Provides one port dedicated for connection to a printer, and a second port dedicated for dial-in from a service computer, typically located off-site. With an off-site computer, programming changes and system diagnostics can be performed remotely, reducing service time for repair or reprogram. Security is maintained by password protection. Standard 4 A Expansion Module provides two taps of 2 A each, 28 VDC, filtered, non-regulated, similar to the standard power supply capacity. Suppression Release Power Supply provides two taps of 2 A each, regulated at 24 VDC* 10%. May also be used for other applications requiring regulated voltage. Use for suppression release requires a front panel mounted release appliqud that is provided with this power supply and also may be ordered separately. Battery Meter Module provides panel mounted ammeter and voltmeter for power supply monitoring. Dual Circuit Class A NAC Adapter Module mounts on the main 4010 printed circuit assembly and provides the additional circuitry needed for Class A operation. Dual Circuit City Connect Module provides the interface required for direct wired reporting to conventional city connection circuits. (Available with or without disconnect switches.) Expansion Power Distribution Module provides two additional termination points for the 1/2 A auxiliary power output, or for one tap of the expansion power supply. Relay Option Module. Provides three relays, one each for Alarm, Supervisory, and Trouble. Relay contacts are selectable for normally open or normally closed and arc rated 2 A @32 VDC maximum. IKLs!.JDIflhIIjJrIIrillxri!mr Up to six of the following modules may be connected to the Simplex N2 serial communications bus. 4606-9101 LCD Annunciators provide remote acknowledge, reset, and alphanumeric status display. (Refer to data sheet S4606-0001.) 24 LED Annunciator Doors are standard on ULC listed models and are available as door-only assemblies for electronics only packages or other aftermarket applications. This option uses the 24 Point I/O module with all points pre-assembled as LED outputs, with individual labels and each LED is selectable as red or yellow. 4605 Series 24 Point hO Modules are available for remote mounting and provide 24 points that can be programmed as either general purpose switch inputs or system controlled outputs. Typical applications are for remote annunciators and monitoring and control of other related processes. (Refer to data sheet S4010-0002.) 84010-0001-9 10/2004 ITEM A 6sttfpiton WAldr 000, 4010-9101 UL Listed 4010 Fire Alarm Control Panel with: door, cabinet, power 120 VAC Beige 4010-9102 supply/battery charger, IDNet interface, 4 MACs. 2 auxiliary relays, and Red 4010-9201 external N2 communications interlace; 4010-9101 and 4010-9102 Beige Control Panel 4010-9202 include Internal common event reporting DACT 240 VAC Red Assembly 4010-9101C English] ULC Listed 4010 FIre Alarm Control Panel; same as above (select one) 4010-9IDICF 120 VAC French except: with 24 LED Annunciator door; and without DACT Beige 4010-9150 UL Listed 4010 Fire Alarm Control Panel electronics only, 4010-9150C ULC I Engfor pre-shipped cabinets, requires door and cabinet 120 VAC j NA 4010-9150CF Listed ordered separately; -9150 has event reporting DACT Optional Expansion Slot Features (two slots are available, select modules as required) Category -ModCl 1Pesr:lPt!n 4010-9810 DACT Module (Common Event Reporting) I Reporting and 4010-9816 Includes two, 7 ft (2.1 m) long RJ45 DACT Module (Point Reporting) I cables Network Modules (select one) 4010-9821 Network Interface Module with fixed, wired connections 4010-9817 Network Interface Module, Modular; requires 2 (In/Out) media modules (see below) RS-232 4010-9811 Dual RS-232 Interface Module Communications 4010-9812 Single RS-232 Interface Module with Service Modem connection (select one) Media Modules 4010-9818 Network Wired Media Module Media modules mount on the 4010-9817 module 4010-9819 Network Fiber Optic Media Module I without impact to slot allocation space. Chassis Mounted Expansion Modules (select as required) tegØ Additional Power Supply (select one) .l: 4010-9813 .. 120 VAC Input 4 A Expansion Power Supply 240 VAC input 4010-9823 4010-9814(CF) Suppression Release Power Supply; 4 A @24 VDC, regulated ± 10%; Includes front panel suppression appliqué; CF suffix selects French 120 VAC Input 4010-9824 240 VAC Input Optional Features (select one) 4010-9820 Battery Meter Module (ammeter and voltmeter) 4010-9625 24 VDC Expansion Power Distribution Module, provides two additional termination points for an expansion power supply tap or the auxiliary power output 4010-9806 Dual Circuit Class A (Stde Z) NAC Adapter Module, two maximum Optional Features (select as indicated) 4010-9809 Dual Circuit City Connect Module Select one maximum 1 4010-9829 Dual Circuit City Connect Module wlo disconnect switches 4010-9803 1 Relay Option Module Accessories Optional Features 4010-9826 120 VAC Auxiliary Relay Kit, allows one auxiliary relay to control up to 1/2 A @120 VAC, select as required; 2 maximum 4010-9830 (CAF) Suppression Release Appliqué, required for suppression release applications; suffix CAF selects a French appliqué 2975-9801 Semi-flush trim, beige, 1-7116° (37 mm) wide 2975-9802 Semi-flush trim, red, 1-7/16° (37 mm) wide Batteries (required II batteries are internal; select one size; two batteries are required) 2081-9272 8.2 Ah Battery, 12 VDC 2081-9274 10.0 Ah Battery, .12 VDC 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC; NOTE: This battery size will not allow bottom entry conduit 2081-9287 25 Ah Battery, 12 VDC Cabinets (select one if pre-shipped) 2975-9215 Red Cabinet Dimensions: 22' H x 18° W x 5-3/8° D (559 mm x 457 min x 137 mm) 2975-9214(CF) Beige Cabinet; CF suffix has French labels Doors (select one If pre-shipped or for use with 4010-9150) 4010-9858 Red Door with dress panel Dimensions: 22" H x 18' W x 5/13" D (559 mm x 457 mm x 16 mm) 4010-9857(CF) Beige Door with dress panel; CF has French labels 4010-9860 (CAF) Beige Door with 24 LED Annunciator and dress panel; CAF suffix selects French for ULC applications Dimensions: 22' H x 18"W x 1-23132"D (559 mm x 457 mm x 44 mm) (see also S4010-0002] 4010-9861° Red Door with 24 LED Annunciator and dress panel As or document revision date: 4010.9829 Is not ULC listed; 4010-9860 and 4010-9861 are listed by UL and ULC and approved by CSFM and FM; 4010-9860CAF is ULC listed and FM approved Only. 6 84010-0001-9 10/2004 ITEM A 4010 Operating Specifications Input Power Requirements AC input. 120 VAC base models ViteRarige 102 to 132 VAC 80 Hz 10 4axmtim Current 2 A AC Input, 240 VAC base models 204 to 264 VAC 50/60 Hz I A AC input with 120 VAC expansion power supply 102 to 132 VAC 60 Hz 4 A AC Input with 240 VAC expansion power supply 204 to 264 VAC 50/80 Hz 2 A EnvirOnmental Operating Temperature Range 32 to 120S17 (0 to 49 C) Operating Humidity Range up to 93% RH. non-condensing @ 100.4 F (38 C) maximum Output Ratings Standard Power Supply Output 4 A total @ nominal 28 VDC 1/2 A maximum of standard power Output switches to battery Auxiliary Power Tap supply voltage backup during mains failure or vnninn Pnr , ,nnk, 0. tn, .1* Arfr1tinr,I A A iTh nominal 28 vnr brownout conditions 'rr', Suppression Release Power Supply Output * Additional 4 A @24 VDC *10% * Each power supply provides two output taps of 2 A each. Current Ratings for Optional Modules and Remote LCD Annunciator dl Mdl - SUpenaSory M oe cue - ' 4010-9810 DACT (Common Event Reporting) 40 mA 4010-9816 DACT (Point Reporting) 40 mA 4010-9821 Network, wired communications 125 mA 4010-9617 Network Modular, add media cards separately 24 mA 4010-9818 Network Wired Media 47 mA 4010-9819 Network Fiber Optic Media 36 mA 4010-9811 Dual RS-232 75 mA 4010-9812 Single RS-232 with Service Modem 100 mA 4010-9806 Dual Class A NAG Adapter 0 mA 4010-9609 Dual Circuit City Connect 20 mA 4010-9829 Dual Circuit City Connect w/o disconnect switches 20 mA 4010-9803 Relay Option Module 10 mA 4010-9860 4010-9861 24 LED Annunciator door 60 mA &ULC4O1Os 4606-9101 Remote LCD Annunciator (refer to data sheet $4606-0001) 65 mA System Current (supplied separate from power supply output) Current 40 MA 40 MA 125 mA 24 mA 47 mA 36 mA 75 mA 100 mA 0 mA 36 mA 36 mA 37 mA 83 MA (all LEDs on) 140 mA Base Sys tern with. no IDNet devices SVISQi!• 195 mA Jarm 50 IDNet devices 230 mA 330 mA 100 IDNet devices 265 mA 365 mA 150 IDNet devices 300 mA 400 mA 200 IDNet devices 335 mA 435 mA 250 IDNet devices 370 mA 470 mA - Current Calculation Information: To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. 7 84010-0001-9 10/2004 ITEM A 4010 Module Layout Reference EM io o: o 0 I IDi 4010-9808 4010-9806 4010-9809 Meter Module' r -9829 or City Module 4010-9825 EsnaIon ' Class A Class A I Module • Module : Skits 1 82 Of : 24 VDC Power, 4010-9808 Disirthulian Relay Module Block - I - ,-" o 4010-9813, 0 : 4098-9914 TV — - - 4010-9823. ' ar4olo-9824 : Expanston Power Supply © © 10movaull's 1111111 a IF Mounting Information / - - - - -. — — TYPIOSI Cal dull entry area (cut holes as required) 1&(457mm) 01 HE Z. 21 OO8 (533 nsa) - luuIIIl([ - - - s-2 -s_14-ll2" (368mm) -w Battery Area No conduit entry or wiring in this area 6' Li Shaded area Is for non-power limited wiring' 14102" 7-3132" (180 mm) __-•-,- Standard door profile (40 mm) _ 6-1 14 _ (159 mm) 314- 5-117 Annunciator (19 mm) (140 mm) door prolile — Wall Ihldcnoss guides for I i ' 1/2" (13 mm) wall board Standard Door—. III 5/8" (16 mm) thick "'WaD thickness guides for I 5/8" (16 mm) wallboard) Annunciator Door, ii internal straps are 1-23132" (44 mm) thick i provided for wiring management i (2 each Side) Door and exposed 11 19 cabinet dimenalon_, foraemreh mount 2-1513Z'(03 mm) Knockout serew/nall holes (for semi-flush mount) Wall board position reference for semi-flush mounl 7)u. Siri9,Iex the S(np1ex logo. Th,eA (we,. WALX707 WA'ui. Siu€aiSvu and TrueAlcri are i,-adeiuoi*s of Two In,en,atio,,aIAG w- its afluliao.s in rim U.1 wrd/or other coamo-jes. NFPA 72 and Na,Io,ral Fire Atom, Code are ,egixiered trademarks ofthe Notio,iol Fire Prolectie,, Assoclai ton (NFPA). 3SirnpIex Tyco Safety Products Westminster" Westminster, MA • 01441-0001 • USA 84010-0001-9 1012004 www.tycosafetyproduc(s-use-wm.com 2OO4 7)aiSoft Proi*ex, Wweiiiisle, All ,ighis issensd. A1Ispe6 Pcafiwacmdotherii0nirliwisktnwi icerecurrea, as of.bzumeni revtrkm daW mid rim srrbjfri to diange n4ihoulnotice, ITEM A CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 9 LISTING No. 7165-0026:0226 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Simplex, 50 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (918) 731-8881 Email: pmatterntycoinLcom DESIGN: Models 4010-9101, -9102, -9201, and -9202 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station (protected premises), proprietary (protected premise), waterflow, and sprinkler supervisory service. Suitable for releasing device service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 4010-9101,-9102,-9201-9202Control Unit 4010-9150 Standard Function I/O 4010-9809-9829 City Circuit Card 4010-9810 Event Report DACT 4010-9816 Point Report DACT 4010-9817 Modular Network Interface 4010-9821 RS-485 Net Interface 4010-9806 Class A Adapter 4010-9811 Dual RS-232 Interface 4010-9812 RS-232 Service Modem 4010-9813 Expansion Power Supply 4010-9814 Suppression Release Kit 4010-9818 Wired Media Module 4010-9819 Fiber Optic Media 4010-9820 Battery Meter Module 4010-9823 Expansion Supply 4010-9824 Suppression Release Kit 2081-9046 Coil Supervision Module 4010-9860,-9861 Replacement Door with Annunciator 4010-9803 Relay Module RATING: 120, 220, 240 VAC primary; 24 VDC secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and Indicating devices. Also suitable for high-rise application when installed with Model 4003 Series Voice Evacuation System (CSFM Listing No. 6911-0026:195). Refer to listee's Installation Instructions Manual for details. Rev. 01-15.09 bh This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 20'I1 Authorized By: FRANCIS MA TEQ, Program Coordinator Fire Engineering Division ITEM A Listing No. 7165-0026:0226 Page 2 of 2 This control Unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly from 7170-0026:226 Rev. 01-15-09 bh It This fisting is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing Is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation Instructions and/or other suitable Information sources. Data Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division ITEM A Specification Summary - Nominal Voltage Rating 12 V!battery Discharge Rating 20 Hour Rate Typical Chart/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90° F (15.6°C to 32.2° C) These baltetles meet the requiements at UL. ULC, and Factely Mutual for use with respective epmenl baftery chargers as listed on page 3. Contact yesriocal Simplex product suppterTar proper baiteenled per smreqàemen fSimpIex Rechargeable, sealed lead-acid design: Lead-calcium grid structure Immobilized electrolyte in absorbent separator High reliability dual seal construction Low maintenance, no need to add water Low self-discharge characteristics One-piece, high impact polystyrene ccli cover UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size For applications requiring 110 Ah batteries: Refer to data sheet 54081-0002 for 4100U systems Refer to data sheet S2081-0012 for 4100/4120 series System Simplexe rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the buttery wiring distances are both minimized. Fire Alarm Control Panel Accessories Cabinet Mounted System Batteries; 2081 Series, Sealed Lead-Acid; 6.2 Ah to 50 Ah Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing fhcility for proper disposal. 30 Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) S2081-0006.16 9/2004 ITEM B Listing No. 7165-0026:0226 Page 2 of 2 This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly from 71700026:226e *Rev. 01-15-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other stitable information sources. ( Date issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Inner cover Absorbent sal used to imrr elei Lead-calciu, C Typical Construction Details Actual appearance will vary with battery size. ni tn.. -- Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator Cell case (high Impact polystyrene) S2081-0006-16 9/2004 ITEM B Battery Specifications c,ac1@2O Hour :Dl sdhrge Rate 'Width, -! llelghtwlth ThñtiiS. ApprDxlmate Weight' 2081-9272 6.2 Mi 6-118" (156 mm) 2-5/8" (67 rnni) 4' (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah 6" (153 mm) 4-1116" (103 mm) 4"(102 nan) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6" (153 mm) 4' (102 mm) 4"(102 mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-&&'(168 mm) 5 (127 mm) 7' (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular case. 33 Ah 12-112" (318 mm) 3-3/8' (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ("square" case, 33 Ah 7-3/4' (197 mm) 5-1/4"(133 mm) 6-314"(171 mm) 26.5 lbs (12 kg) use for new) ________________ _______________ 2081-9296 1 50 Ah I 9-1/2" (241 mm) I 5-1/2" (140 mm) I 8-7/8" (225 mm) 1 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When installed In a fire alarm control panel, they are to be of Identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information * - I Simplex Control Panel Model Series (see legend and notes below) A 06A 4( 4005. 4006 & 4009 - 4bW$ 41D0 &410 402% Model - 400P .—Z - --,- s3ba g 4or 6-Unit) (4ot6-Unit) 20819272 6.2 Ah It It 2081-9274 10 Ah 2081-9288 12.7Ah / 1 1 1 If If f I If 2081-9275 18 Ah Note 3 1 Ext Ext Note 2 1 1 1 2081-9287 25Ah Note Ext "=... if I Ext 2081-9271 33 Ah E- Note 3 Ext ç.. Note 3 1 Ext Note 4 (rectangular) MINHER 2081-9276 33 Ah Note Ext Note It 1 Ext ('square) 2081-9296 50 Ah Note 3- Note 1 Ext Ext / = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 Shaded areas = Not applicable NOTES: These batteries meet the requirements of UI, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. S2081-0006-16 9/2004 11 ITEM B External Battery Cabinet Compatibility Reference Z Externally Mounted Battery Battery Cabinets without Chargers • H Cabinets with Chargers (connects to charger in panel) dei 2Offi4 1J -•:' ! : 2081.9270** *u8 O8-82 Q9O4 1Q09!92 2081-9275 18 Ah I 1 1 1 ,f 1 If 2081-9287 25 Ah 2081-9271 (rectangular) 33 Ah 2081-9276 ('square") 20819296 50 Ah / f if f Batteries smaller than those listed are normally mounted in the product cabinet. Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional Information. 1= Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specification Reference NO ARR 2081-9281 2-Unit. 4100 style cabinet without charger, with solid door and battery shelI primarily intended for 50 Ah batteries Beige 25-3/4' W *20-3/4' H x 643/4° 0 (654 mm x 527 mm x 171 mm) 2081-9282 Red 2081-9270- External battery cabinet without charger Red 26-1/2° W x 12" H xl 2" D (673 mm x 305 mm x 305 mm) 2081-9301' External battery cabinet with charger 2081-9302* External battery cabinet without charger and with meters for voltage 2081-9303' External battery cabinet with charger and with meters for voltage and current 4009-9801 For up 1018 Ah External battery cabinet without charger, 161/4' W 13-1/2" H x4-1/8° 0 batteries with solid door and battery harness, for close-nippled mounting to fire alarm control panel cabinet Beige (413 mm x 343 mm x 105 mm) 4009-9802 For up to 33 25-3/4'W *20-3/4" H *4-1/8" D - batteries (654 mm x 527 mm x 105 mm) 4081 For up to 50 Ah Companion cabinet with charger for the Beige or 22-1/2° W xl 6-3/4° H *8-3/8" 0 Series°° batteries 4010 and 4004R fire alarm control panel Red (672 mm *425 mm x 213 mm) * Refer to Simplex data sheet S2081-0002 for additional information. Refer to Simplex data sheet 84081-0001 for additional information. Tya,. 5wq,Is and thaSirnpIeIoo we iradenigs,b of Tyco In lernalisuscil Ses-vlcrs AG or in qflillak's in the U.S and/or . oihsrcoun,rlei. 13Sirnplex TYCO Safely Products Westminster' Westminster, MA •01441-0001• USA S20981-0006-16 9/2004 wN.ycosafeypmducts-usa-wm.com ©2OO Tjnv(eyPnxtire lVesTh.instes 4ua1. A# ac/icvIonswxlatherfta,mukjnxIjonn ianm uusaf*scunsuesava*rn ekise ansi wsp athjecl to drwsgnwWwzii natk. ITEM B ,Simplex TrueAlerl® Multi-Candela Notification Appliances UL, ULC, CSFM Listed;. FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSyncTM Operation Compatible Iikutt*s Visible only (VJO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Listed to UL 1971 and ULC S526 Strobes provide synchronized flash for use with: 4006,4008, 4010, and 410013 Series fire alarm control panels with NACs selected to provide strobe Synchronization or SmartSync two-wire control** 4009 lDNetTh NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* * Refer b pap 2 for WordNstIi This product hasbeen approved by the CorniaState Fire M,nhal SFM) pursuant toSection 13144i of the Catifernia Heath and Satety Code. See CSfMListhig 71254102&316 for at me values andier cenneerning material presented ar this daciarienLflisel -exajn,ialion, revision, and posathie canestallea Refer page 2 for tdn5 status otre guards. Additional lislhrgs may be ap your lucid simpiex prcdnel mWler forthe latest status. LiSings and approvals wider Simplex Time Recorder Co. am the pmolTyco Safety Product Westminster. Wall Mount Strobes FIRE fi Ceiling Mount Strobes II1 Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings area one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number, r-IL.1'Lx iil(1t}1ikDUfl6UJsll. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Ml 1TiY It! Ut Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI Al 17,1; the appropriate model building code: BOCA, ICBO. or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). "Simplex muili.cande!a SmartSync tm-vke hornlslrobe apptance operation Is protected larder one ormore of the 1000wligiLs. Patent Pianbera 5,559,49Z 5,622,427; 5,865,527; 5.886,620 6,281,789; 6.954,137:7,006.911; and 7,006,003. Em C U'1TiI7;m 117iT1 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. fl7TsirnTI Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). Product Selection III Multi-Candela Visible Notification Appliances (Strobes) Mp,eI Mournln Color 'FIRE" Lettering 4906-9101 Red White Hausln 4906-9103 Wall White Red 4906-9102 I I Red I White 4906-9104 I Ceiling I White I Red SmartSync two-wire control Is available from: 4006,4008,4100U, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Dosc4tlofl Multi-candela strobe with intensity selectable as: 15.30. 75. or 110 candela; synchronized flash rate; SmartSync two-wire control compatible Wall Mount Strobe Adapters Otto : Dlñénslrns 4905-8937 Red I Surface Mount Adapter Skirt; use to cover 1-1/2' (38 mm) 5-318"H x 5-1/4"W x 14/6' D 4905-9940 White deep surface mounted boxes (136 mmx133 mmx4l mm) Total depth with strobe = 4-318' (111 mm) 49059931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16' x 5-3/4° x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box. requires 7-7/8"x Adapter Plate 4905-9931 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter :Moel. :1 jition :DimepsIns Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8° x 3-118" x 0.060' 0 4905-9910 handy box; not needed when using 4905-9926 guard (124 min x 79 mm x 1.5) Synchronization Modules (refer to data sheet 54905-0003 for additional information) soriPon•• : flimenslons 4905-9914 Class B I Synchronized Flash Module; epoxy encapsulated with I inlout 18 AWG (0.82 mm) wire leads, rated for 2 A NAC. 1-3/8' x 2-7/16° x 13/16' (35 mm x 62mm x 20mm) 4905-9922 Class A requires 5 mA for power 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4' x 4-118' x 11-10 0 4' (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model DImensions 4905-9992 Red cover with white 'FIRE' lettering For Wall mount strobes 5-119'H x 5' W x 1-1/2' D 4905-9993 White cover with red "FIRE' lettering • (130 mm x 127 mm x 38 mm) 4905-9961' Wall mount I 6-1116" H x 6-1/16' W x 3-1/8" 0 Red wire guard with mounting plate, compatible with I semi-flush or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905_9926* Ceiling mount 6-1/8"x 4-316'x 2-7/8° deep (156 mmxIll mm x 73 mm) * UL listed by Space Age Electronics Inc. S4906-0001-4 9/2009 ITEM C IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly Electrical above bottom iT'ioxoutline of compatible boxes NFPA 72 requires 80"(2.03 m) that the entire lens minimum be not less than 80° and not greater than 96° above the finished floor S4906-00014 912009 ITEM C nhe Snecificatic Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); No wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8"H x 5"W x 2-3/4° D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 76 cd itO Cd - Wall Strobe Setting (see Note 2 below) eo mA 94 mA 186 mA 252 mA Reference RM Currents 18VD 53 mA 84 mA 165 mA 24 mA ______ atothervoltage.. •: 4Qj• 03- mA 1-1-24 mA Housing Dimensions(with lens) 4-L-011bx -o,o u r,izrmm k rU mm x Dr àii Maximum RMS Current Rating per 't cd 30 Cd 75 adCoiling '110 Cd Strobe Setting (see Note 2 below) 75 mA 125 mA 233 mA 316 mA ReferenceRMSCurrenta 1.8VC 6mA - 111 mA 27 mA 1.9111-m at other voltages 50 mA 23 mA 155 mA t513 NOTES: "Regulated 24 VDC' refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1. 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAG under worst case conditions. The maximum RMS current fisted Is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) /m LTh m/) Mounting is compatible with ( •% 0 ___________ single gang, double gang, and A l _________________ ___________ 4" (102 mm) square boxes, __ ______1-1/2°(38 mm) deep, by others LfL.LfCJL/jZfLJë5LJ1u1 'full Wiring access hole Wiring terminals '° Nil Transparent housing and lens assembly Intensity selection ___ plug, accessible only [ I] [ factory setting Is 15 cd from rear of housing; Removable cover Strobe intensity (tool required) viewing slot Mounting Holes: 4" square (4) Single gang (2) Double gang (3) 3 4905-9931 Adapter Plate 4905-9931 Adapter Plate nal Wire Guard reference only, can be used on other mounting options) Ceiling Mount Strobe Installation Reference Single gang box (Wiremold I V5744S) 2-1/4' (57 mm) deep, supplied by others Handy box, 11-11&(38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T.bar with clips (ERICO No. 512 or equal) II 0.00 4905-9910 Adapter Plate, required for surface mount with handy box unless using the 4905-9926 wire guard [UL1IIELII 1Celllng mount strobe ,Optional 4905-9926 wire guard /with mounting plate Strobe Intensity 'I viewing slot Intensity selection plug, accessible only from rear of Ions housing: factory setting is 15 Cd I. --------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4' (102 mm) square box profile, 1-1/2' (38 mm) deep Optional 4905-9961 Wire Guard Strobe Optional Surface Mount Adapter Skirt. 1-1/2' deep: 4905-9937, Red; 4905-9940, While (conduit knockouts are provided on all four sides) Tyco Lye registered frademerk of rycoinirnwtfwmlsen'ices GiiibH mid is us ed u,uler license. Sbnpk,. the Simpkvlogo. IDNeI. Th.e4leii mad SmeriSyaw are trademarks of 7)'coln:eraiatioqnl 14,1. and us q/flhimes and are used wider license. NFPA 72 mid Nodaim! Fire Alnnii Code air registered mulenuarks ofMe National Fire Protection Assneloflo,, (NFP,U. Tyco Safety Products Westminster' Westminster, MA • 01441-0001 • USA S4906-0001-4 9/2009 .Simplex wwNt'Jcosafetyproducts-usa-wm.com 0201w afei Products ffestWmder.All,ighisjssaiwui All sp colionswufotheru,tfon,wuionslani,w irorecunentasofducwnentrerisfon datea,,dweuthj.rt to ciwege withoag,,o,ire. ITEM C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0316 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplex, 50 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattem@tycoint.com DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and -9103 are for wall mount Models 4906-9102 and -9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide MAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 od INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 06-23-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ITEM C fiSimplex TrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSyncTM Operation Audible/Visible Notification MEA (NYC) Acceptance with Horn and Synchronized Flash, Non-Addressable Ikuug*i Audible/visible (AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount: Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair SmartSync horn activation of Temporal pattern, March Time pattern (at 60 BPM), or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Operation requires connection to a compatible SmartSync operation NAC or to SmartSync Control Module (SCM) 4905-9938 Wall mount ANs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional UL/LJLC listed sound damper for locations requiring attenuation of 5 to 6 dBA (stairwells) small rooms, highly reverberant areas, etc.) Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall of- ceiling mount A/Vs* Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 caudela with visible selection jumper secured behind strobe housing Regulated circuit design ensures consistent flash output and provides controlled inrush current Listed to UL 1971 and ULC S526 Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich sound output suitable for either steady or coded operation (Temporal or 60 BPM March Time pattern) Listed to UT.. 464 and ULC S525 Wall and Ceiling Mount ANs Dscrinti Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each modcl can be selected for strobe intensity output, on-sitc model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount A/Vs install using standard 4" electrical boxes. Color choice is determined by model number. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Refer tapage 2trguard Using.This product. has been approved by the CaitornlaSt* Fin Moralist (CSFM) pursuant to Section 13144.101 the Ca&oniia Health and Safety Code. See CSFM Listing 7125.061a317 for allowable values andfer conditions concerning material presented in this document It is subject to re-exisninafon. revision, and poetide cancelafon. Accepted for use —C of New York Department of Buildings —MEA3S-93E. Refer b page 2 for Isting stales of vdre guards. Additional tislings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Fine Recorder Co. ore the properly of Tyco Safety Products Wesbuinstur. ' Simplex multi-candela SmaiSync heo-vke bomistrobe applIance operation is protected under aria or more of the following U.S. Patent Woburn: 5,559;492 5.622,427; 5,865,527; 5,886.620; 6,281,786,6,954,137; 7.005,971; and 7,006.003. S4906.0002-5 9/2009 ITEM D Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the 1'fallonal Fire Alarm Code (NFPA 72), ANSI Al 17.1; the appropriate model building code: I3OCA, ]CBO, or SBCCJ; and the application guidelines of the Americans with Disabilities Act (ADA). Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. SmartSync operation mode allows a Iwo-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." 4006,4008, 4100U, and 4010 Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. I'1r, Multi-Candela A/Vs Model unting -Housing-Color-'.'FIR" l.et(e,ng teserlpftbn >Mo 4906-9127 wall Red White 4906-9129 white Red Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire 4906-9130 4OflQlOR RedCeiling White control White Red Wall Mount NV Accessories 'Model :pQlptiQn' -• : •- - :. fimO!1slOns 4905-9937 Red I Surface Mount Adapter Skirt use to cover 1-112' (38 mm) deep 5-3/8' H x 5-1/4" W x 1-5/8' D (136 mmxl33 mmx4l mm) White surface mounted boxes depth with strobe = 4-3/8' (111 mm) 4905-9940 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4' x 0.060' Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 min x 1.5 mm) 2915-9145 Red Mounting Box. requires Adapter Plate 4905-9931 ' 7-716' x 5-1/8 x 2-3/4" D (200 mm x 130 min x 70 mm) Optional Sound Damper; package of 20; field installed adhesive backed horn output attenuator; reduces output to 6 ciBA 1-314' Diameter (44.5 mm) 4905-9838 NOTE: After Sound Damper installation, measure sound level to ensure with 0.31"(8 mm) sound opening compliance with applicable code requirements SmartSync Control Module Model Description. Milmenslons SmartSync Control Module with Class B or Class A output; mounts in 4" 4'x4-1!8'x 1-1/4'D 4905-9938 (102 mm) square box; refer to data sheet S4905-0003 for details J (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description Dimensions 4905-9994 Red cover with white 'FIRE' lettering 5-1/8' H x VW x 1-1/2" D 4905-9995 White cover with red "FIRE' lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimnsions Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16' H x 6-1/16"W x 3-1/8' D 4905-9961" or surface, mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927" Ceiling Red Wire Guard for mounting to flush mounted electrical box 8-112'x6-118'x3' (216 mm x 156 mm x 76 mm) 4905-9928' Red Adapter Plate, required to mount guard to surface 9" x 7' Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover I 1-1/2' deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 min x 38 mm) 4905-9916 Red * UL listed by Space Age Electronics Inc. 2 S4906-0002-5 9/2009 ITEM D Mounting Hales: 4° square (4) Single gang (2) Double gang (3) l Transparent housing and lens assembly Intensity selection .110 is plug, accessible only I I from rear of housing; ( I Is Notary setting is 15 Cd V j Strobe intensity viewing slat 3 Removable cover ON E (tool required) MPRITUREV ?, M, Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Rash Rate and Synchronized NAC Loading Environmental; Temperature and Humidity Connections Horn Output Characteristics Model Type Horn Output Sound Type (see Note 2) Ratings (see Note 2 for Reverberant Chamber Test, polar dispersion per UL 464 @10 ft (-3m) reference) Anechoic Chamber Test, per ULC S525 © 3 m (-10 ft) Housing Dimensions (with lens) Maximum RMS Current Rating per Wall Mount Strobe Setting (see Note 3 below) tRMS.urrents 1.VDC I Housing Dimensions (with lens) Maximum RMS Current Rating per Ceiling Mount Strobe Setting (see Note 3 below) Regulated 24 DC; see Note 1 below 1 Hz; with up to 35 synchronized strobes maximum 32° to 122° F (0° to 50° C); 10% to 93%, non-condi Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 terminal for in/out wiring 2400 to 3700 Hz sweep, modulated at 120 Hz rate Wall Mount Steady Coded - 86dBA 82dBA 88dBA 94dBA 90dBA 5-118°H x5° Wx 2-3/,V 'D (130 mm x 127 mmx70 mm) 15cd 75 mA 116 mA 221 mA S7 41A . X S-(IW W x 2-5mT1(TrrmlwrT, . mm x of mm 1 cd 86 mA 132 MA 250 mA 76mA t11mA 98d8A 111.0. 285 mA 23:OIA :io 320 mA per NAC mslng at 100° F (38° C) to 3.31 mm?,); two wires per Steady Coded 87dBA 83dBA NOTES: 'Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, SignalIng Devices fort/ic Hearing impaired, changes effective May 11 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VOC Is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Polar dispersion per ULC S525 testing = -3 dBA at +1-40° off-axis; -6 dRA at +1- 50° off-axis. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) /LTh L m7Th Mounting Is compatible with .- - single gang, double gang, and 0 4" (102 mm) square boxa%1W. " ° 1-112" (38 rein) deep, by " y others - . Optional 4905-9838 ° ° Sound Damper, field attached to attenuate sound5toBdBA - Wiring terminals for &nartSync operation IMPORTANTI WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r ...,—Electrtcal above bottom : r box outline of compatible boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80° and not greater than 96" above the finished Door S4906-0002-5 9/2009 ITEM D Ceiling Mount AN and Guard Installation Reference ( Ceiling reference. 4 (102 mm) square box, surface mounted box / 1-112"(38 mm) minimum depth f.: Ceiling reference, flush mounted bo, Optional 4905-99151-9916 Adapter, recommended for surface mounted box Wiring terminals are located behind the housing Optional 4905-9928 Adapter Plate. required for surface mounted electrical box Four mounting clamps included, two each side - Optional 4905-9927 Red Wire Guard 4 Strobe intensity viewing slot lntensityselecticm plug. accessible only from rear of lens housIng; factoly selling is 15 cd --------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt I Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard r Surface mount conduit and box shown for reference 4 '1 (102 mm) square box profile, 1-1/2 (38 mm) deep ] O J 4905-9961 Optional Wire Guard 4905-9931 Adapter Plate 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Optional Surface Mount Adapter Skirt, 1-112" deep: 4905-9937. Red; 4905-9940. White (conduit knockouts are provided on all four sides) Tyco is a registered tnrdemark of 7)'eo l,,rernalionol Services CmbH and is used wider lkeiise. Si,, oles the Shikx logo. 10Net. TnteA lee,. and SmariSyne are rrade,nwlss of Tyco luren,aiianal Ltd. and Its affiliates and we used render license. NFPA 72 and National Fire Alarm Code are rrenfenini*s oftire National Fire Protection Association (NPPA). O Tyco Safety Products Westminster • Westminster. MA • 01441-0001 • USA 54906-0002-5 912009 .Simplex 02009 TyroSofeyPsxthrcIs Wcs,inInsrer.A1l,ih,sreserred. All specjikations and other l,,firnnaslon show, rreixcnnxntasofdarometexvisloniaitdare.wbjettadgewiileauinoilce. ITEM D CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0317 Page 1 of I CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED L1STEE: Simplex, 50 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-6542 Fax (978) 731-8881 Email: pmaftem@tycoint.com DESIGN: Models 4906-9127, 4906-9129 wall mount and Models 4906-9128 and 4906-9130 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 16-33 Vdc Candela: 15, 30,75. 110cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation Instruction Manual for details. NOTE: 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and!or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verily correct operational requirements or installation criteria. Refer to listee's data shed, installation instructions and/or other suitable Information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEQ, Program Coordinator Fire Engineering Division ITEM D B$implex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET Il® or lDNetTM Communicating Devices and MEA (NYC) Approved* Addressable Manual Stations Individually addressable manual fire alarm stations with: Power and data supplied via MAPNET I€et addressable communications using a singi pair** Operation that complies with ADA requirements Pull lever that protrudes when alarmed Break-rod.supplicd (use is optional) Models are available with single or double action (breakglass or push) operation UL listed to Standard 38 Compatible with Simplex: Model Series 4010/4100/4120/4020 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 communicating device transponders (CDTs) equipped with MAPNET IT communications Compact, sealed construction: NEMA 2 enclosure rating for minimal dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Plush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes )pr.rinfir The Simplex model 4099-9001 addressable station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (TAM) constantly monitors status and communicates changes to the connected control panel via MAPNET U or JDNet communications wiring. This FUM has been approved by the Chihloith State Fee Marshal (CSFM) pursuant to Section 131441 of the Calliorida Finale and sarety Code. See CSFM Listing 71SJ.0025221 for alowable values arePre conditions concening material presented in this docunuxi. S is subject to re.examburtion. revision, and possSile cancellation. Accepted for can- City NewYork Detrulmante(llieldmgs-MEA35-935. Add(ttonal listings may be applicable. contant Simplex for the latest status. 2000 Simplex Time Recorder Co. M rights reserved. 4099-9001 Addressable Manual Station (front and side view) 4099-9002 4099-9003 With 2098-9828 Breakglass Push Institutional Cover kit Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break-rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. MAPNET 11and iDNet addressable comnunicalions designs are protected by U.S. Patent No. 4.196,025. 84099-0001-5 8/00 ITEM E Addressable Manual Stations Model. . Descllptton. 4099-9001 Single action on Addressable manual station red housing with white 4099-9002 Double action, Breakglass operati letters and white pull lever 4099-9003 Double action. Push operation Accessories 2975-9178 Drlplion . Surface mount steel box, red Refetne Refer to page 3 for dimensions -- 2975-9022 Cast aluminum surface mount box, red 2099-9813 Serni-flusti him plate for double gang switch box, red Typically for retrofit, refer to page 4 2099-9814 Surface trim plate for Wiremold box V5744-2. red 2099-9819 Flush mount adapter kit, black Refer to page 4 for details 2099-9820 Flush mount adapter kit, beige 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 Specifications and Communications MAPNET II or IDNet, 1 address per station, up to 2500 ft oanel. uo to 10.000 ft (3048 m) total wirinu distance (inch T_: from fire Address Means - 131pswitch,8position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 930/o RH at 100° F (38° F) - Housing Color Red with white raised lettering Material Housing and pull lever are Lexan® polycarbonate Pull Lever Color White with red raised lettering Housina Dimensions 5" H x 33/4W x D (127 mm x 95 mm x 25 mm) Single Gang Box Mount 4" Square Box Mount Single gang box, 2 112" deep 4'('102 mm) square box, 2 11111"(54 mm) minimum (64 mm), RA00#500 or equal depth, RACO #231 or equal (supplied by others) (supplied by others) ° 0 Mount flush or with 1116"(2 mm) -i maximum extension -- _ 4" Square box TvAthwverplate I CICI 10 jl DO NOT RECESS __ __ U Station _ _ FIRE]()[ALARJ side view Single gang cover plate. 4' ----- (19 mm) extension, RACO #773 or equal (supplied by others) Single gang I Wall suace PULL DOWN box outline Semi-Flush Mount Side View Simplex Time Recorder Co. 2 S4099-0001-5 8/00 ITEM E Addressable Manual Stations Surface Mounting Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 29754178 Box 5 3116'H x 4"W x 2 3116"D (132 mm x 102 mm x 56 mm) (ordered separately) \ Knockouts located top and bottom 2975-9022 Cast Box 5Hx37l8°Wx23I16"D (127 mm x 98 mm x 66 mm) 1nrrImrr cnmtph,l I Access for 314° threaded 5" conduit located top and bottom (127 MM) -I 1° (25.4 mm) Ii-3 3W(95 mm) .f' 4099 Series Addressable Manual Station Surface Mount Side View with Internal Detail 1 1/4" Field wiring _ (32 ________ Simplex 2975-9178 box (shown for inference) mm), (shown for reference) 1l1riiit*i Refer to NFPA 72, the Mr€ional Fire Alarm Code (reference section 5-8), and all applicable local codes for complete requirements for manual stations. The following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. Mounting shall be with the operable part not Less than 3 1/2 ft (1.1 m) and not more than 4 1/2 ft (1.37 m) above floor level. At least one station shall be provided on each floor. Additional stations shall be provided to obtain a travel distance not more than 200 fl (61 in) to the nearest station from any point in the building. When manual station coverage appears limited in any way, additional stations should be installed. Address setting under resealable label (accessible with cover open) 2518° (67 mm) Station cover hinges open for installation access Switch wiring (prewired) Simplex Time Recorder Co. 3 S4099-0001-5 8/00 ITEM E Addressable Manual Station, Additional Mounting Information For retrofit and new installations, additional ___ Wuiemold compatible mounting boxes receptacle box and the required adapter plates 2099-9814 Surlace trim model V5744-2 are shown in the illustration to rWiremaid box 51/8' H x 5"W (supplied by others) the right. (130 min x 127 mm) Eq Please note that these addressable manual stations Two gang switch box, each will also install onto single 3 Ax 2" W x2 314" D gang Wiremold box model (76 mm a 51 mm a 70 mm) V5747 but will overlap the (supplied by others) box. Wiremold V5747 4099-9001 lONet ! 0wN J J 0 dimensions are. 4 5/8" H X addressable station 27/8"Wx13/8"D(117nim x73 inmx35mm). r\•Lz1v_J •1 2099-9813 Semi-Rush trim 10r2 gang switch box. 6"Hx41/2'W (152 mm a 114 mm) Flush mount adapter kit 2099-9819, Black 2099-9820, Beige ( S4099-0001-5 8100 Westminster, Massachusetts 01441-0001 USA OSiniplex visit us on the world wide web at www.slmplexnef.com All specifications and other inrmation shown were current as of printing and are subject to CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM ~Q~9 LISTING No. 7150-0026:0224 Page 1 of 1 CATEGORY: 7150 - FIRE ALARM PULL BOXES L1STEE: Simplex, 50 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: Models 099-9001,-9002,4003,4010, -90I0TSP, -9010TTP, -9011. -9012, -9O12TSP, -90I2TTP, and -9031C non-coded addressable manual pull stations. Models 4099-9001 and -9010 are single action stations. Models 4099-9002 and -9011 are breakglass stations. Models 4099-9003 and -9012 include a push bar which must be punched in before being able to grab and pull down the actuating handle. Model 4099-9031 C is a double action station. Refer to listee's data sheet for additional detailed product description and operational considerations. RA11NG; 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. Models are intended for use with listee's Models 4010, 4100,4100U and 4020 control units (CSFM Listing Nos. 7170-0026:226.7165-0026:160 or 7170-0026:187, 7170-0026:250 or 7185-0026:251 and 7165-0026:178). Model 4099-9013C is intended for use with Model 4010 control unit only. For indoor use only. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. Rev. 01-26-20010fm This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, Installation Instructions and/or other suitable Information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ITEM E B Simplex TrueAlarm? Analog Sensing UL, ULC Listed; FM, CSFM, TrueAlarm Analog Sensors - Photoelectric, and NYC, MEA Approved* Ionization, and Heat; Compatible Bases and Accessories Ikiii* TrueAlarm° analog sensing provides digital tTansmisslo nsor values via MAPNET I or lDNet, -wire communications** Fire alarm con provides: Individual sensitivity selection for each sensor Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allowing accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check that verifies sensor integrity Automatic environmental compensation Display of sensitivity directly in percent per foot Multi-stage alarm operation Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors: Seven levels of sensitivity from 0.2% to 3.7% Heat sensors: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Ionization smoke sensors*: Three levels of sensitivity; 0.5%, 0.9% and 13% For use with Simplexe: 4010, 4020,4100, and 4120 Series control panels Universal Transponders and 2120 TrueAlarm CDTs equipped for MAPNET II operation Magnetic test feature Functional and architecturally styled chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Optional accessories include remote LED alarm indicator and output relays UL listed to Standard 268 These products have been appseed by the Cfafnia Stale Fire Marshal (CSFM) pritteSection 131441 oltheCiforen Health and Safely Code. See CSFM Listings 7212-=:218.7271-6=231. 7M=6:216. and 73000026:217 for atfowdete vabes and or conditonu clsewning material presented in this document. it is subject to re-eomnfrmllon. resteka and ponathlecancelattea Accepted for use -Cifyol New York DI of dks—f&A35-nEReferta pap 4 (or ULC usIng status. Additiortal lislings may be aç0cable. carried your local Simplex product supplier kwthe lateutotatus. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement that is digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance a] arms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example. a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's T.ED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. ' TmeAlarm analogsensors and MPPtET Hand lDNetcceiimoutons amprotechad hyone or 52.784.794O2S DES. 377.480. S4098-0019-8 12)01 ITEM F TrueAlarm Sensor Bases and Accessories Base mounted address selection: Address remains with its programmed location Accessible from front (dipswitch tinder sensor) Automatic Identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design Magnetically operated functional test Mounts on standard outlet box 4098-9792, Standard sensor base 4098-9789, Sensor base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (unsupervised) 4098-9791, Sensor base with supervised relay driver 'si'rinfir TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionization, or heal sensors. Each sensor's output is digitized and transmitted to the system lire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. output (not compatible with 2120 CDT); Electrical Box Requirements: (boxes are by Others) Relay operation is programmable and can be manually Withoutrltet: 4' octagonal or 4 square. 1-112" deep; single gang. 2" deep operated from control panel MM nft: 4" octagonal or 4' square, 1-112" deep. Use with remote mount 2098-9737 relay with 1-1/7' extension ring Also includes wired connections for remote LED C[1102 mm) Square Box 4' (102 mm) Octagonal Box alarm indicator or 4098-9822 relay Surface mount reference 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A ® 120 VAC (requires external 24 VDC coil power) 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @28 VDC; non-power limited rating of 1/2 A 6j 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box ALAM (shown in illustration to right) S Simplex ( f 1-112 (38 mm) minimum box depth Flush mount reference, mount even with final surface, or with up to W (0.4 mm) maximum recess --------------------------------------------------- 2098.9737 Relay (mounts In 4098-9822 Relay (mounts base electrical box or remotely) In base electrical box) Relay Size: 2-117'X 1-112" X (3.75 cubic Inches) (64 mm X 38mm X 254 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. 'I I- e-31r(ls2mm) 4098-9832 Adapter Plate, recuired for 1I4 mounting to 8Il!f98 mounted boxes (6.4 mm) 14 4-718" (124 mm) 15/18" k (24 mm)L o TrueAJann Bases 4098.9789, -9791, & -9792 84098-0019-8 12/01 ITEM F TrueAlarm Sensors 1k. i* Sealed against rear air flow entry Interchangeable mounting EMIIRH shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Listed to UL Standard 521 for 60 ft (18.3 m) spacing for 135° F (57.2° C) alarm, and 40 ft (12.2 m) spacing for 155° F (68° C) alarm Smoke Sensors: Photoelectric or ionization technology sensing 3600 smoke entry for optimum response TrucAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without ratc-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F(68* Q. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. Ilowever, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. (Refer to specific panels for availability.) Ii_4-7/8"(124 mm)_-I 4098-9733 Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. A built-in screen keeps insects from entering the smoke chamber. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. I. 4-718" (124 mm) "I T CLED 2-1/8" (54 mm) L III I—• 4098-9714 Photoelectric Sensor with Base 361*I11Ft1flTh9rsia. TrueAlarm Ionization sensors use a single radioactive source with an outer sampling ionization chamber and an inner reference ionization chamber to provide stable operation under fluctuations in environmental conditions such as temperature and humidity. Smoke and invisible combustion gases can freely penetrate the outer chamber. With both chambers ionized by a small radioactive source [Am 241 (Americium)], a very small current flows in the circuit. The presence of particles of combustion will cause a change in the voltage ratio between chambers. This difference is measured by the electronics in the sensor base and digitally transmitted hack to the control panel for processing. Three levels of sensitivity are available for each ionization sensor: 0.5, 0.9, and 1.3% per foot of smoke obscuration. T LED sttus (54 min) I 4098-9717 Ionization Sensor with Base Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Afann Code. On smooth ceiling, smoke sensor spacing of 30 ft (9.1 m) maybe used as a guide. For detailed application information. refer to 4098 Detectors. Sensors. and Bases .4pplication Manual (574-709). S4098-001 9-8 12/01 ITEM F TrueAlarm Sensor Bases NOW. Description Compatibility. '•.otinthgRqulrem.er1!s 4098-9792 (C) Standard Sensor Base, no options Sensors 4098-9714. -9733, & -9717 4" octagonal or 4° square box,1-112' mUl. depth, with 3" 0-ring; or single gang box, 2" mm. depth Sensor Base with connections for Sensors 4098-9714, -9733, & -9717 4098-9789 (C) Remote LED Alarm indicator 01 2098-9808 remote LED alarm 4° octagonal or 4" square box with 3°C-ring, Unsupervised Relay Indicator or 4098-9822 relay li1a: Box depth requirements depend Sensor Base with connections for Sensors 4098-9714, -9733, & -9717 4098-9791 (C) Supervised Remote Relay and on total wire count and wire size, refer to accessories list below for reference. 2098-9737 remote relay (supervised) 2098-9808 remote alarm indicator or connections for Remote Alarm Indicator or Unsupervised Relay 4098-9822 relay (unsupervised) TrueAlarm Sensors _..> ModeL Description : Compatibility Mouatln.Reqttemeics. 4098-9714 (C) Photoelectric Smoke Sensor Bases 4098-9717 (C) Ionization Smoke Sensor 4098-9789, and 4098-9791 Refer to base requirements 4098-9733 (C) Heat Sensor TrueAlarm Sensor/Base Accessories Model Dscfiptton Compatibility MgunJigIequIrementa. Remote Mounting requires 4" octagonal or 2098-9737 Supervised Relay, mounts remote For use with 4098-9791 base 4" square box, 1-112" minimum depth - or In base electrical box ° U Base Mounting requires 4° octagonal box, 2-1/8" deep with 1-112" extension ring 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Single gang box, 1-112" minimum depth Relay, tracks base LED status Bases 4098-9789 and 4098-9791 4098-9822 (C) (unsupervised, mounts only in base 4" octagonal box, 2-118" deep with 1-112" electrical box) extension ring Required for surface or semi-flush 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 mounted 4" square box without 3" 0-ring, and for surface mounted 4° octagonal box Refer to publication 4098 Detectors, Sensors; and Bases Application Manuel (574-709) for additional information. ULC listed model numbers are designated by (C) and require a "C" suffix such as 4098-9794C. 0111511 W.?W.M :mr Gäi.OpatiflgS.pe MAPNETIlor cifiCatiW1s nicatIons and Sensor Supervisory Power Communications Connections Screw terminals for lnlout wiring, 18 to 14AW( Remote LED Alarm indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG UL Listed Temperature Range 32° to 100° F (0° to 38" C) Operating with 4098-9717 or 4098 -9733 Temperature Range with 4098-9714 32° to 122" F (0" to 50" C) 15° to 122" F (-9° to 50° C) Humidity Range 10 to 95% RH Smoke Sensor 4098-9714 Photoelectric Sensor Ambient Ratings 4098-9717, Ionization Sensor Air velocity is 0-2000 ft/mm (0-610 rn/mm) Air velocity Is 0-100 if/mm (0-30 rn/mm); Altitude Is up to 8000 ft Housing Color 4098-9791 Base With SupeMsed: Remote. Relay 2098-9737 (sqepage2 Externally Supplied Relay Coil Voltage Frost White for contamttd(ing$) 18-32 VDC (nominal 24 VDC) Supervisory Current 270 isA. from 24 VDC supply Alarm Current with 2098-9737 Relay 4098-9B22;il19uperv1sod Rfay, Rquirementsfor Bases 40t9iB9. Externally Supplied Relay Coil Voltage 28 mA, from 24 VOC supply and 4O9891cseea2for6ofltaCtrr8tlhgo) 18-32 VDC (nominal 24 VOC) Supervisory Current Supplied from communications 1 Alarm Current 13 mA from separate 24 VDC supply 7)ca, Sbuplex 11w 5impke Iego, TiveAbmu, M,1PNIITII, tvullDNe? are lrwkusartc of Tja hzs.'r,w,lonal Sen'kcn AG or Its affiliates ij, Ike US a,ubor other com,Iaks. ( NFPA 72130 registered Iraviensark of11w National Fire 1',ole cliPs Association (flFPA). SinipIex WestmInster, Massachusetts 01441-0001 USA wwws9np1exfletCOm S4098-0019-8 12101 I 21)0! 5IIJ1p(ec 1mw Kacon1'r( a. LIDII MM-US rc lyco conçanjy, .1,, lOIS rescswa. All .peciJrco1ionc and oilier u,foraitailoir shoirti were cnrnrnl re oJthiciimeiil revision dale imdwa subject to c1wm5e withuat no!!ce. ITEM F CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of I CATEGORY: 7300 --MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: Simplex, 50 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattem@tycoint.com DESIGN: Models 4098-9789,-9789E. 9789T5P, -9789T1P, -9791,-9791E, -9791TSP, 9791T1P,-9792, -9792E, -9792TSP, 9792TTP, -9793,-9793E, -9793TSP, -979311P, -9794, -9794TSP, -9794TTP, -9795, -9795TSP, -9795T1P, -9796, -9796TSP, -9796TTP; tGSA4098-9792, 9793, *..9795 and *.9796 smoke detector bases. These bases act as an Interface between the sensor and the MAPNET controller. Bases are intended for use with the following units: Models 4098-9714 and GSA4098-9714 series photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:231): and Models 4098-9733 and GSA4098-9733 heat detector (CSFM Listing No. 7270-0026:216). Models 4098-9795, -9795TSP. -9795TrP, -9796, -9796TSP, -9796TTP; *GSA4098_9795, and *_9795 are only intended for use with Models 4098-9754 or *GsA4098..9754 photoelectric smoke detector *(CSFM Listing No.7272-0026:218). Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, -9794TSP, -9794TTP, -9795, -97OSTSP, -9795TTP; and G8A4098-9795 employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control Unit that can produce the temporal pattern. NOTE: Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This fisting is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, Installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division ITEM F CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272— PHOTOELECTRIC SMOKE DETECTOR LISTEE: Simplex, 50 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mettem (978) 731-8542 Fax (978) 731-8881 Email: pmattern©tycolnt.com DESIGN: Models 4098-9714, -9714T5P, -971411P, -9754 -9754TSP, -975411P; GSA4098-9714, and -9754 analog photoelectric type smoke detectors. Units are intended for use with smoke detector bases Models 4098-9789 97891SP. -9789TTP, -9791, -9791 TSP. -9791 TTP, -9792, -97921SP, 9792TTP, -9793; 9793T5P, -9793TTP, -9794, -9794TSP,-9794TTP; *GSA4098..9792, and ••9793 (CSFM Listing No. 7300-0026:217). Models 4098-9714, -9714TSP and -9714TTP are listed for use with Models 4098-9750,-9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755. -9755TSP and -9755TTP duct detector units (CSFM Listing No. 3240-0026:241). Models 4098-9754, -9754TSP, -9754TTP; *G8A4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed Models 4100, 4010, 4020, 4120 and *4008 series fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Rev. 03-03-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not an 'L endorsement or recommendation of the Item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation Instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MA rEQ. Program Coordinator Fire Engineering Division ITEM F CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0026:0216 Page 1 of I CATEGORY: 7270— HEAT DETECTOR LISTEE: Simplex, 50 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattem@tycoint.com DESIGN: Models 4098-9733 or GSA4098-9733 electric combination rate compensated, fixed temperature, and rate of rise heat detector. Intended for use with models 4098-9789, -9791. -9792, *..9793; 4GSA4098-9792 or *9793 detector base (CSFM Listing No. 7300-0026:217). Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 135oF and 155oF INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/temperature ratings and UL label. APPROVAL: Listed as heat detector for use with listee's separately listed 4100, 4010, 4020.4120 and *4008 series fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Rev. 03-03-2005 This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an 4: endorsement or recommendation of the item listed. This listing Should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable Information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ITEM F Simplex UL Listed; FM and CSFM Approved* TrueAlert® Notification Appliances SmartSyncm Adapter Module for Non-Addressable Notification Appliance Circuits (NACs) Model 4905-9815 Iakuii.i Converts a SmartSync NAC into separate 24 VDC audible and visible appliance outputs: Power and communications are supplied by the SmartSync operation NAC Up to two SmartSync Adapter Modules can be connected to a SmartSync NAC Operation is compatible with: Simplexe fire alarm control panels providing SmartSync two-wire horn/strobe control SmartSync Control Module (SCM) model 4905-9938 (refer to data sheet S4905-0003 for additional information) Appliance control output features: Operation modes are: visible and audible appliances both on; or visible appliance only - with activation determined by the connected control panel An on-board DC-DC regulator ensures proper appliance voltage and provides self-resetting overcurrent protection Audible output rated for up to 50 mA Visible output rated for up to 250 mA Wiring to audible and visible appliances is supervised with conventional reverse polarity operation; opens or shorts are reported to the control panel Status diagnostics: A visible status LED will light if a wiring fault is detected by either of the on-board output notification appliance supervision circuits General mechanical features: Mounts in standard 4-11/16" (119 mm) square electrical box Cover plates (required) are available for surface or flush mount, ordered separately in Covers provide status LED viewing Screw terminals for wiring connections UL listed to Standard 864 'Tha readuot has been appreemi by lie Califoinia Stale Fire Marshal (CSFM) pursuant to Section 131441 of the Carmia health ant Sately Code. Sea CSFM Listing 7OOOO2th315 for aSawableyaluas andha coidlkins conoenhing unatenal presented In thin dommedL la aublect to mexamination, reveten, and possible ca,ceilatlon. This productwen not ULC Sated orappoved by MEA (NYC) asoldocimeni roVisba data Adiltlonal Isiligs maybe applicable; contact auw tecal SImplex product supplerfor the latest stable. Listiogs mid approvals tmderskaplex Tene ReosuderCo. are the property of T cdectsWestmèieJer Conventional -. audible appliance arMymc japtar I! Conventional / - visible appliance - AC with SmartSync 2-wire operation Fire alarm control panel providing SmartSync operation NACs (41001.11 style shown for reference) SmartSync Adapter Module, Typical One-Line Wiring Reference Irnuiirni Special Notification Requirements. Standard SmartSync operation notification appliances activate horns and/or strobes in response to commands received from the SmartSync operation control source using a two-wire connection. For applications where appliances other than the standard SmartSync appliances are required, the SmartSync Adapter Module provides a separate audible and visible output controlled by the SmartSync operation control source. Typical applications are for connection to special weather-proof appliances, appliances with particular sound output characteristics (special bells or chimes), or for connection to appliances that arc required to satisfy specific aesthetic requirements. Maintains SmartSync operation System Advantages. With the SmartSync Adapter Module, non-SmartSync appliances can be controlled while still benefiting from the SmartSync operation ability to provide separate audible and visible control using a two-wire connection (U.S. Patent No. 6,281,789). 54905-000571 6/2003 ITEM G non- aj Compatibility with circuit protectors. When connected to remote appliances (up to 200 ft from the adapter) that exit the building and may be exposed to harsh electrical environments, the notification appliance wiring is compatible with Simplex circuit protectors. Compatible protectors are listed on page 3 and should be connected both where the wiring leaves the building and where it connects to the appliances. Provisions for shielded wire. For applications where ( notification appliance wiring may be exposed to electrical noise, twisted, shielded wiring is recommended. The adapter wiring terminal block has provisions for connecting the shield(s). I a rN WE R-111--re 11111 M. p. 4905-9815 SmartSync Adapter Module; requires surface or flush mount cover plate 4905-9817 Surface Mount Cover Plate Select one for each 4905-9815; painted beige 4905-9818 Flush Mount Cover Plate TrueAlert Adapter Installation Reference Cover plate depth: 4-11116' (119 mm) square box. ?(51 mm) 0.24' (6 mm) for flush mounted box 0.35' (9 mm) for surface mounted box (54 mm) deep], or equal (supplied by others) minimum depth; ref. RACO 257 [2-1/8 Status .. 1 indicating LCD F[M -j-4— Module Assembly SmertSync Adapter Light pipe For LED viewing I 0 SmartSync Adapter Module Detail , c IJf 5-114' (133 m) square ________________________ Mounting holes 4-11/16' for cover plate (4) (119 mm) Depth into box = Terminal block For __- 1-9/32" (33 mm) wiring connections Appliance mode selection switch Holes for connecting to mounting box (4) - 5'(127mm) 2 S4905-0005-1 6/2003 ITEM G Specifications Electrical Input Voltage Range to 33 VDC; see notes below Input Current Supervisory al :12mA I audible and visible appliance loads (see NAG loading below) S. Alarm Output Voltage Range 2 VDC on-board regulator limits inrush current to appliances at 550 mA Audible Appliance Output Rating 50 mA @24 VDC Visible Appliance Output Rating 250 mA @24 VDC On-board regulator is in effect when NAG voltage drops below 20 V. Increase appliance current rating by 10% to determine NAG current requirements for NAG Loading Impact worst case line voltage. Example: Assume audible appliance is rated 40 mA Visible appliance (strobe) is rated 180 mA @20 VDC (150 mA @24 VDC) Alarm Current = 12 mA+ (1.1)(180 mnA+40 mnA)= 254 mA Wiring Reference Appliance Distance from SmartSync Adapter 200 ft maximum (61 m) Supervision Resistor 10 ka. 112 W; two required, one located at each remote appliance W'nlng Connections Screw terminals for 18 to 12 AWG (0.82 mm2 to 3.31 mm2) Compatible Circuit Protection (required when wiring leaves the building for outdoor appliances, mount one at each end of wiring) 2081-9044, Overvoltage Protector, 200 mA maximum 2081-9028, Isolated Loop Circuit Protector, 5 A maximum 2081-9027, Isolated Loop Circuit Protector. 200 mA maximum Mechanical and Environmental Dimensions (adapter mounted in bracket, see page _2 for reference drawing) 4-11/16 H x 5' W x 1-9132"D (119 mm x 127 mm x 33 mm) Mounting Plate Material Sheet metal, galvanized Temperature Range 32 to 120 F (0 to 49 C) intended for indoor operation Humidity Range 10% to 90% RH non-condensing at 90 F (32 C) - NOTES: The SmartSync adapter Is required to be connected to a NAG that provides SmartSync two-wire operation. The rated voltage range listed is the absolute operating range. Operation outside of this range may cause permanent damage to the SmartSync adapter. S4905-0005-1 6/2003 ITEM G CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 13 LISTING No. 7300-0026:0315 Page 1 of I CATEGORY: 7300— MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: Simplex. 50 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 Email: pmattern@tycoint.com DESIGN: *Models 4905-9815 SmartSync Adapter Module and 4905-9816 TrueAlert Adapter Module. Units allow conventional notification appliances to be operated on a SmartSync notification appliance circuit or TrueAlert signal line circuit. The adapters can employ either one audible and one visual appliance or one combination audible/visual unit. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: The 4905-9815 is listed as control unit accessory for use on any listed control unit's NAC output, when used with the 4905-9938 Sync Control Module (CSFM Listing No. 7125-026:235); or on a NAC output of Simplex's 4010 or 4100U control units (CSFM Listings 7165-026:226 and 7166-026:251) or on a NAG output of Simplex's 4009-9201 or 4009-9301 NAC Extenders (CSFM Listing No. 7300-0026:214) The 4905-9816 is listed as a control Unit accessory for use on Simplex's 4009-9401 NAC extender (CSFM Listing No. 7300-0026:214) or 4100U control unit when provided with Models 4100-5120, 5121, or 5122 True Alert Power Supply (CSFM Listing 7165-0026:251). Refer to listee's installation instruction manual for details Rev. 10-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an it endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ITEM G ;- SYSTEM $ SENSOR Outdoor Selectable- Output Horns, Strobes, and Horn Strobes SpectrA leif Advance outdoor selectable-output horns, strobes, and horn strobes are rich with features that cut installation times and maximize profits. Features Automatic selection of 17-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15,15n5, 30, 75,95,110,115,135,150.177, and 185 Plug-in design with minimal intrusion into the back box Tamper-resistant construction Universal mounting plate for wall- and ceiling-mount units Mounting plate shorting spring tests wiring continuity before devices are installed 'Weatherproof per NEMA4X. IP56 Usted to UL 1638 (strobe) and UI 464 (horn) -Rated from -40°Fto 151'F Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Agency Listings SItINALItID 0- @LM <> IVIEA ED .1 7I64IR'O,n 4nU %,w,,cmIe, lim9 AO appron The SpectrAlert Advance series offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor horns, strobes, and horn strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40F to 15 IT Like the entire SpectrAlert Advance prod:jct line, these devices include a variety of features that increase tneir application versatility while simplifying installation. All devices cature plug-in designs with minimal irtrusion into the back boy, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faiIts. All horns, strobes, and horn strobes use a universal mounting plate with an onboard shorting spring that tess wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12-or 24- volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. ITEM H SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpecLrAleit Advance outdoor horns strobes and horn strobes shall mount to a weatlierprool back box A uriiveial rriuunsiiig plate shall be used loi mounting ceiling and wall prorJucts.11ie notification appliance circuit wiring shall terminate at the universal mounting plate. Also. SpectrAlert Advance pirrith icts, when used with the Sync-Urct&7 Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9and 173 volts 21-volt-rated notification appliance circuit outputs shall operate between 11 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15. 15/75,30.75,95. 110,115,135.1S0. 177.and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______listed to UI. 1971 and shah be approved for lint protective service-The strobe shall be Wired as a primary-signaling notification appliance and comply with the Americans with l)isabilitiesAct requirements for visible signaling appliances flashing at 1 Hz over the strobes enike operating voltage range.The strobe light shall consist of xenon flash tube and associated lens/reflector system.l he strobe muss be installed with its weatherproof back box in order to remain outdoor approved per UL The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall lx'a System Sensor SpectrAlert Advance Model ______listed to UL 1971 and UI 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobes entire operating voltage range The strobe light shall consist of a xenon (lash tube and associated lens/reflector system. The horn shah have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the soundcr.Thc horn or horn strobe models shall operate on a coded or non-coded power supply.] he horn strobe must be installed with its weatherproof back box in order to remain outdoor approved pci UL The hurn strobe shall be suitable for use in wcL environments. Operating Temperature -40F to 151'F (-40't to 66Q Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 OC/FWR or regulated 24 DC/FWR' Operating Voltage Range5 8 t 17.5 V(12VnominaD or 16t0 33V94Vnom&ial) lnputTerm1naJ Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (Including lens) 6.8diameterx 2.5h4h (173 mm, diameter x 64mm high) Wall-Mount Dimensions (Including lens) 5.6% x4 YWx 2Sl) (142 trirri I x 19mmWx64 mm D) Horn Dimensions 5.61. x 4.7Wx 13D (142 119 19nimWX 33 mm 0) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1 Wx 20(1.15 mm Lxi 30 mmW x 51 mm 0) Ceiling-Mount Weatherproof Back Box Dimensions (SA-WBBC) 7.1 diameter x Z0 high (180mm diameter x Si mm high) Notes: I. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panti outputs. 2. P. S.PC.and SC products will operate at i2Vnominal only for is and 15/75 Cd. ITEM H UL Current Draw Data Candela 8-17.5 Volts DC FWR 16-33 Volts DC FWR Standard 15 123 128 66 /1 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range ISO NA NA 246 220 177 NA NA 281 251 UL Max. HornCurreit0raw(mRM5) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR lempoial High 57 55 69 15 Temporal Medium 44 49 58 69 Temporal Low 38 44 L44 48 Non-Temporal High 57 56 60 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 --- 56 69 Coded Low 40 46 52 50 185 UI-Max. Curr—ent braw (.A RMS), DClnput NA NA 2-Vfire Horn Strobe, 8-17.5 Volts 15 15/75 286 258 Standaed Candela 16-33Volts 15 Range 15/75 (15-11~ cd) 30 75 95 110 115 Tempoial High 131 14/ 19 90 107 1/6 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 TcmporalLow 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 113 145 75 85 107 163 187 707 716 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 /8 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 112 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporallow DC Input 137 154 16-33 Volts 135 150 80 177 185 90 105 161 FWR Input 184 16-33 Volts 135 150 707 177 711 185 Temporal high 245 259 290 291 Temporal High 215 231 758 265 Temporal Medium 235 753 288 29/ Temporal Medium 209 774 250 259 Temporal Low 732 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 2/0 303 309 Non-Temporal High 233 2111 275 281 Non-Temporal Medium 747 259 293 299 Non-Temporal Medium 719 732 767 767 Non-Temporal Low 238 254 791 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduted In accordance with this table. U5ted Candela Candela rating at -40F 15 Do riot use bc1ow32'F 15/75 30 75 44 95 /0 110 110 115 115 135 135 150 150 177 177 185 1185 Horn Tones and Sound Output Data - 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC PAIR 1 leinporal High /8 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Icinporal Low 71 73 75 75 83 80 94 89 4 t'1onlèmporai High 87 82 119 88 93 92 1(10 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 71 Coded High 82 82 88 88 93 92 101 101 81 Coded Medium /8 /8 85 115 90 90 9/ 98 9' Coded Low 75 /5 81 81 88 85 96 97 Settings 7. 8 and 9 are not available on 7-wire horn strobe. ITEM H SpectrAlert Advance Dimensions Wall-mount horn strobes Ceiling-mount horn strobes 'çoy Wall weatherproof back box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK' 2-Wire Horn Strobe, Standard cci, Red, Outdoor 137RHO 2-Wee Horn Strobe, High cd, Red, Outdoor P2WKIe 2-Wire Horn Strobe, Standard at White. Outdoor P2WHK 1 2-Wire Horn Srrobe,i ugh Cd, White, Outdoor P4RKt 4-Wire Horn Strobe. Standard cci. Red, Outdoor P4WI( 4-W1re I lorn Strobe, Standard cd, White, Outdoor P2RHK-120 2-Wire Hot Stiobe, High cd, Red, Outdoor, 120V Wail Strobes 5RK' Strobe, Standard act Red, Outdoor SRHK.t Strobe, High cd, Red, Outdoor SVWt Strobe, Standard cd, White. Outdoor SWHK" Strobe, High cd, white, Outdoor Ceiling weatherproof back box Ceiling Horn Strobes PORK 2-Wire Horn Strobe. Standard c4 Red, Outdoor PC?RI 1K 2-Wire Horn Strobe. High cd, Red, Outdoor PC2WK 2-Wire,l iorn Strobe, Standard cd, White. Outdoor PC2WHK 2-Wire, Horn Strobe High cd, White, Outdoor PC4WK 4-Wire, Horn Strobe. Standard cd, White, Outdoor PC4WHK 4-Wire, Horn Strobe. High Cd, White. Outdoor Ceiling Strobes SCRK Strobe, Standard Cd, Ik4 Outdoor SCRIik Strobe, I ugh cd, Red, Outdoor SCWK Strobe. Standard Cd, White, Outdoor SCWHK Strobe, High cci, White, Outdoor Horns lIRK HoFr% Red, Outdoor Notes: Add'-P'tonuodoi icumber ro plain housing (no'Fiie.'nssridng an wver),egj'2ieC4! t Add-rto model number for weatherproof replacement device (no back box inchidecU, especially for use with weatherproof outdoor hush mounting plate,WrP and WIPW 'Standard cd"refers to strobes that include IS. 15/75,30.75,95.1 10, and 115 candela settings, 'High af refers to strobes that Include 135, 150,177, and la5candela settings. "\ SYSTEM 3825 Ohio Avenue. St. Charles IL 60174 $ SENSOR- Phone 8W-SENSOR2 - Fatc 630-377-6495 aeronei.clae9.,2 se ITEM H CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING- BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0189 Page 1 of 1 CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc., 3825 Ohio Ave,, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Ext: 1185 Email: trish.linhart©systemsensor.com DESIGN: Models HR, HW Horns and CHR, CHW chimes. Intended for indoor use only unless otherwise indicated. Models may be followed by the suffix 1( indicating indoor or outdoor use. W suffice models are suitable for outdoor applications at temperatures from -40 Degrees F to +151 Degrees F (-40 Degrees C to +66 Degrees C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Models CHR and CHW are intended for private mode use only. Suitable for wall or ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VdcNFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. Rev 12-01-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results andlor other data but does not make an independent verification of any claims. This listing is not an 1L endorsement or recommendation of the item listed. This listing should not be used to verify correct operational , requirements or installation criteria. Refer to listee's data sheet, installation instructions andlor other suitable Information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Pmgram Coordinator Fire Engineering Division ITEM H SimplexGrinnell BE SAFE. A Tyco International Company SimplexGr!nnell LP 3568 Ruffin Road. South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simolexorinnell.com License Number: 802591 SIMPLEX GRINNELL L P Business Information: Classifications: Bonding: P0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number: (918) 283-0300 Partnership 12/28/2001 12131/2009 This license is current and active. All information below should be reviewed. I.]*!slt1li1I00 CIO ELECTRICAL C16 FIRE PROTECTION CONTRACTOR CONTRACTOR'S BOND This license flied Contractors Band number 81880913 in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2007 This license filed Bond of Qualifying individual number 81880915 for RONALD (3ILBERT MAYLE in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01101/2007 This license tiled Bond of Qualifying Individual number 82165933 for DEAN RAYMOND ENGEL In the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Entity: Issue Date: Expire Date: License Status: Effective Date: 04/03/2009 This license has workers compensation insurance with the NATIONAL UNION FIRE INSURANCE COMPANY OF PITTSBURGH, PA Workers' Policy Number: WC 060-18-8740 Compensation: Effective Date: 10/01/2009 Expire Date: 10/01/2010 Miscellaneous I!]*L*Aifl[•I Information: 10128/2005 ASO CERTIFICATION REMOVED 9/29/2009 REV.#: 0 PROJECT #: 480-XXXXXX-XX1L1XfXXXX SimplexGrinnefl BE SAFE. A Tyco International Company SimplexOrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tela: (858) 633-9100 Fax: (858) 633-9101 w!w'.simDIexarinneIL corn SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty-is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell In this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. 912912009 REV.#: 0 PROJECT #: 480-XXXXXX-XI4OP2fXXXX Ia's1L'8ran:dIE4IIfJJ1 Buyer !s Guide Complete Product Information Installation Instructions Value Added Features & Benefits Technical Information Return To index ' Print This Page NOT ALL PVC-COATED GALVANIZED RIGID CONDUIT IS CREATED EQUAL ONLY ETL-LABELED CONDUIT CAN PROVE ITS PERFORMANCE PLASTI-BOND REDH20T.. 10 TIMES LONGER PRODUCT LIFE AT NO ADDITONAL COST NO EQUAL! Wr ETL THE MARK cm (eT ) OF PROVEN PERFORMANCE! IF FACT ONE, Plasti-Bond PVC-coated galvanized rigid conduit is authorized to carry both the ETL-verif led mark of performance and a UL-rated label. Ocal is not. FACT TWO: In independent ETL product performance evaluation, Plasti-Bond was consistently maintained successful bonding of protective PVC coating during extended hot water immersion. In fact.. over the course of 200 hours, Plasti-Bond performed ten times more reliably than Ocal. Ocal's bonding adhesion failed quickly during the identical test. In real life applications failure of PVC to bond with the conduit's metal substrate leads to corrosion destruction and costly product failure. FACT THREE: ETL-verified heat and humidity tests showed equally dramatic performance superiority of Plasti-Bond when compared in identical testing to Ocal. Eli Verified PVC-001 The PVC coating adhesion (EI) performance of this product has been ETL verified to the liflertek ETL SEMKO High Temperature H20 PVC Coating Adhesion Test Procedure for 200 hours. 1llFl Certificate Number: 3072346-004 PROVE if TO YOURSELF HERE'S WHY Plasti-Bond HAS BEEN APPROVED TO CARRY ETL PERFORMANCE VERIFICATION - AND OTHER CONDUIT BRANDS HAVE NOT. PVC External Coating Adhesion Plastl-Bond REDH20T vs. Ocal Blue COsei WHO" of hot water Immersion I - Hot Wft' W*n Time a - ICur PVC External Coating Adhesion Plasti-Bond REOH20T vs. ON Blue Cmapsoson Hrsm MUM nv 1551. ir0 cc I I... • ktYponu Fe Time DEMAND THAT YOUR SUPPLIER OF PVC-COATED METAL CONDUIT PROVE IT TO YOU... WITH THE ETL-VERIFIED LABEL OF PERFORMANCEI 1100 US Highway 271 South • Gilmer, TX 75644 Phone: 903/843-5591 • T 152 MEL1=1 7- :Mzi In repeated, independently confirmed ASTM accelerated tests, the exterior and interior coatings of Plasti-Bond REDH20T consistently performed successfully where as other products consistently failed. Plasti-Bond REDH20rs bond stays strong after immersion testing. The PVC coating protects conduit from corrosion by remaining reliably adhered to the metal. After Identical Immersion testing this Is what bonding failure looks like. When a test tab is pulled on this competing product it strips away completely, exposing metal substrate. What does that mean? Faure. When a test tab is pulled with pliers it breaks away cleanly proving that the adhesive bond is actually stronger than the plastic itself. What does this mean for the user? IIaximani Comaon Protection. Plasti-Bond REDH20T has a stated performance level of 200 hours in boiling water and 30 days in a heat and humidity test with no loss of adhesion. Our word is our bond, and our bond Is your assuronce of the best available con osion protection ) Y ir• js crick eweyadr 4Tfä iioo us Highway 271 South • Gilmer, TX 75644 Phone: 903/843-5591 • Return To Index Print This Page AEPTM... Adhesion Enhancement Process ... is a proprietary treatment system developed to provide an unequaled bond between our PVC and the hot-dipped galvanized conduit it protects. Two Realities About Bonding 1.Surface preparation is the key to a good bond. 2.The quality of the bond determines the quality of the corrosion protection. AEP,,.Plastl-Bond REDH2OT'S Answer To The Challenge Of Bonding Our AEP process for Plasti-Bond REDH20T conduit and fittings prepares and controls the zinc coating so it will receive, and hold, the PVC coating. This is accomplished with proprietary mechanical and chemical methods, as well a special primer coating that only Plasti-Bond REDH20T has. The end result is superior PVC bonding to the metal and the additional backup corrosion protection of zinc. Plasti-Bond REDH20T outperforms other coated conduit brands because it was prepared right.., right from the start. PrnTECHNothbig Can Tch Oir Tnrd! Pr0TECHTM is a system that provides our conduit threads with unsurpassed corrosion protection. The ProTECH system represents an investment of almost $2 million with a single goal of delivering to you the highest quality coated conduit thread possible. After PVC coating of the conduit, the automated, computer controlled ProTECH process starts with a laser trimming operation to remove excess PVC from the conduit ends. Next is mechanical surface preparation of the previously chemically cleaned conduit threads. This is critical because surface preparation is the key to a good bond. Next, the clean pipe threads are hot-galvanized using specially designed equipment, including 3-axis robotic arms. After hot-galvanizing, the threads are coated with a clear polyurethane spray, protecting the galvanized thread from corrosive attack. Nothing has touched the zinc coating of our threads! 1100 US Highway 271 South • Gilmer, TX 75644 Phone: 9031843.5591 •www1ajçf.1om :elurn To Index PVC Coated Galvanized Rigid Conduit Specifications PVC coated galvanized rigid conduit with red urethane interior coating protects conductors from mechanical damage and corrosive attack. Electrical continuity is maintained across assembled joints. 40 mil grey PVC exterior coating 2 mill red urethane interior coating PROTECH threads - A clear urethane coating over hot galvanized threads 12 trade sizes from 1/2" through 6' Shipped in 10' lengths Plastic thread protector caps are color coded for quick identification of conduit size. Thread Protector Cap Caters: Black- for 1/2" sizes, 1/2", 1-1/2, 2-1/211, 3-1/2" Red- for 1/4" sizes, 3/4", 1-1/4" Blue- for even sizes, 1", 2". 3,4", 5", 6" as UL Listed, (Standard 6) with PVC as the primary corrosion protection for the steel conduit The underlying zinc coating is a supplemental corrosion protection coating. Restricted for use with threaded fittings only. Corrosion protection properties of exterior zinc coating were not investigated. Er evc- has ii EK YWANA-4- a 2 F7 frit2n -i- .,r4__Jj PistI4 tnd REDIi2OT, Th Extra Ditarsc I,, og ProtectIo,i fro on CrrtisIon As aclosed system, a coated conduit installation is only as good as its threaded joints. Plasti-Bond offers you ProlechW' a unique technology of hot galvanizing our conduit threads. This new system provides two important benefits to the user. First, the zinc coating coverage is consistently uniform. Second, the threads are hot galvanized after the conduit is PVC coated. This means that nothing in the PVC coating process can damage the zinc coating on the threads, delivering a "virgin thread" to the user. These features offer much improved corrosion protection for the new threads. After hot galvanizing, we apply a clear urethane topcoat to ensure the threads remain corrosion free before and after installation. APPROVAL STAMP 1100 US Highway 211 South • Gilmer, 1)( 75644 Phone: 903/843-5591 9 :eturn To index Print This Page F Simple Steps To Ordering To order the PLASTI-BOND coated elbows follow these simple steps to creating a catalog number 1' Determine Proper Prefix. For steel conduit elbow use the prefix: PRHEL- For aluminum conduit elbow use the prefix: PRELB-AL- Add the conduit trade size needed to your catalog prefix. Example - 112" steel conduit elbow: PRHELB-112 Enter an "X" to represent "by" as in "2X4°. Example - PRHELB-1/2X 41r Enter the desired elbow degree of bend. Example - 450: PRHELB-112X45 For a coated steel, 1/2" elbow with a 450 bend, the catalog number would be: PRHELB 1/2X45 STEP 5 AND 6 FOR CONFIGURING CATALOG NUMBERS FOR LARGE RADIUS ELBOWS 5 Enter an "X" to represent "by" as in "2X4. Example - PRHELB-112X45X & Enter the desired elbow radius. Example - 30: PRHELB-112X45X20 For a coated steel, 1/2° elbow with a 45° bend, and a special radius of 301 the catalog number would be: PRHELB-1/2X45X30 This number can then be looked up in the listing of pricing to determine price and availability. Call 903-843-5591 for custom orders, customer service and more Information on Plasti-Bond REDH20T. APPROVAL STAMP Coated Elbow Specifications PLAS11-BOND REDH20T factory bent standard radius elbows are available and ready to ship. Factory bent elbows are more accurate, quicker to install and more economical, because they save field bending time and do not waste materials. Electrical continuity is maintained across assembled joints. 40 mil Gray PVC exterior coating 2 mil Red urethane interior and thread coating 12 trade sizes from 1/2" through 6" Available in 90, 60, 45, and 30° bends Plastic thread protector caps are color coded for quick Identification of conduit size. Thread Protector Cap Colors: Black- for 1/2" sizes, 1/2°, 1-1/2", 2-1/2", 3-1/2" Red- for 1/4" sizes. 3/4°, 1-1/4" Blue- for even sizes, 1", 2",3".4",511,611 UL Usted, (Standard 6) with the PVC as the primary corrosion protection for the steel conduit The underlying zinc coating IS a supplemental corrosion protection coating. Restricted for use with threaded fittings only. Corrosion protection properties of exterior zinc coating were not investigated. Et WNIF— i-d 1100 US Highway 271 South • Gilmer, TX 75644 Phone: 903/843-5591 • mUtird.com Return To Index Print This Page Dimensions APPROVAL STAMP Diagrai LegeiU A = Radius at inside of bend. B = Radius at center line of bend. C = Radius at outside of bend. D = Offset at inside of bend. E = Offset at center of bend. F = Offset at outside of bend. STANDARD RADWS ELBOWS DlAMEW$ Ml]l OIFT Metric Nominal Nipple (standard) Size Size External hflamSi Lengths A 3 0 8 F Tangent Designators inches Inches Inches Inches Inches inches Inches inches inches inches Inches 16 1/2" 0.920" 0.632" 11-1/4" 3.70" 4.25" 4.71' 6.040" 6.500' 6.960' 2.250" El 21 3/4" 1.130" 0.836" 12-1/2" 3.94" 450" 5.07' 6.685" 7.250" 7.815' 2.750" 27 1" 1.395" 1.063' 14-314" 5.05" 5.75" 6.45 7.928' 8.625 9.323' 2.875" IJ 35 1-1/4" 1.740' 1.394' 17-3/4" 6.38" 7.25' 8.12" 9.567' 10.437" 11.307 3.187" 41 1-1/2" 1.980" 1.624' 19-3/4' 7.26" 8.25' 9.24 10.635" 11.625" 12.615" 3.375" 53 2" 2.455" . 2.083" 22-1f2 8.27" 9.50" 10.73" 12.086" 13.313" 14.541" 3.813" 63 2-1/2" 2.955" 2.489" 28" 9.02" 10.50" 11.98" 14.776" 16.253" 17.731" 5.753" El 78 3" 3.580" 3.080" 32" 11.21" 13.00" 14.70" 17.000 18.790" 20.580" 5.790" 91 3-1/2" 4.080" 3.570" 39-1/2" 12.96" 15.00" 17.04" 20.920" 22.960' 25.000" 7.960" 103 4 4.580" 4.050' 39-1/2" 13.71 16.00" 18.29" 20.890' 23.180" 25.470" 7.180" 129 51 5.643" 5.073" 59-1/2' 21.18' 24.00" 26.82' 32.079" 34.900" 37.722" 10.9lX? 171 155 6" 6.705" 6.093" 76" 26.65" 30.00" 33.35" 41.088" 44.440' 47.793" 14.440" PLASTI-BOND REDH20T factory bent elbows are also available in later than standard radii to accommodate your special needs. Simply follow the four steps for standard radius elbows on the previous page, then continue with Steps 5 and 6 for large radius elbows. Refer to the table below to determine which radius is available for the size of conduit you need. To use the Large Radius Elbow table, find the elbow radius required in the first row. Then look down the column to determine which conduit sizes are available in that radius. Use this information in Steps 5 and 6 on the previous page to build a catalog number. LARGE RADIUS ELBOWS Radius B in 1 1 1 Inches 12" 15" ir 18" 24' 24" 30" 30" 36" 36" 36" 42" 42" 42" 48" 48" 48- E Offset 1'5-1/2'" 1149-1/4" 2'S" 2'10' 3'4" 3'S" 3'll" 311-1/4" 43-1/4" 4'5" 46" 4"9-1/2' 5114" 5'1-114" 5'3-1/4" Nipple Length 26" 3'O" 12'1N'23" 3"10" 46" 41911 55 5'9' 6"7" 6'7" 7'S"7'4" 7'6" 8'l"' 8'4" B'S" 8'lO" Tangent 5-W' 6-1/4" 9" 8" 10" 10" 11" 11" 11-1/4" 15-1/4" 11" 12" 15-1/2' 12-1/4" 13-114" 1"Pipe 1" 2-1/2" 15-1/4" 2-1/2" Sizes In 2" to 3" 2" to 4" to 2" to 4" to 4" 5" only to 4" 5" only 6" only to 4"' 5" only 6" only to 4" 5" only 6" only 1100 US Highway 271 South • Gilmer, IX 75644 4 Phone: 903/843-5591 0 wwwf1.jom PVC coated rigid metal conduit couplings with red urethane interior coating connects coated conduit sections. Electrical continuity is maintained across assembled joints. PVC sleeves on couplings seal off on conduit PVC coating when assembled to prevent corrosive liquids and vapors from attacking threaded joints. PVC Coating on Coupling Pvc Sleeve .'.I .. Conduit _VLEo See "Thmad and Coupling- Technical DelaO for reVenerim ,4 40 mil gray PVC exterior coating 2 mil red urethane interior coating over galvanized threads a 12 trade sizes from 1/2" through 6" Sealing sleeves on both ends Molded external ribs on 1/2 - 4" to prevent tool damage during assembly Couplings are straight tapped e UL Usted Standard 6 All female pipe openings are provided with a PVC sleeve sized to fit tlghtiy over the PVC coated conduit when assembled. This prevents corrosives from contacting Threaded joints. Thread and Coupling Technical Data COUPLING J7IREADS Total Pitch Outside Length At End Diameter of Threads of Thread Metric Pipe Nominal With Threads Effective to Vanish 3/4 in. Size We Steel Weight Per 100 Ribs Per Length Point Taper Aluminum Designators Inches Catalog # (POUndS) Inches Inch Catalog # D 16 1/2" PRCPLG-112 19 1.344' 14 .5337' .7815' .7584' PRCPLG-AI.-1/2 El 21 3/4" PRCPLG-314 32 1.531' 14 .5457' .7935• .9677' PRCPLG-AL.3/4 27 1" PRCPLG-1 40 1381' 11-1/2 .6828' .9845' 1.2136' PRCPLG-AL-1 35 1-1/4" PRCPLG-1-1/4 50 2.156' 11-1/2 .7068' 1.0085' 1.5571' PRCPLG-AL-1-1/4 41 1-1/2' PRCPLG-1-1/2 69 2.469' 11-1/2 .7235" 1.0252' 1.7961' PRCPLG-AL-1-112 53 2' PRCPLG-2 93 2.969' 11-1/2 .7565' 1.0582' 2.2690' PRCPLG-AL-2 63 2-1/2' PRCPLG-2-1/2 123 3.594" 8 1.1375' 1.5712" 2.7195' PRCPLG-AL-2-112 O 78 3" PRCPLG-3 217 4.250' 8 1.2000' 1.6337' 3.3406' PRCPLG-AL-3 91 3-1/2" PRCPLG-3-1/2 422 4.875' 8 1.2500' 1.6837' 3.8375' PRCPLG-AL-3-1/2 D 103 4' PRCPLG4 391 5.250' 8 1.3000" 1.7337' 4.3344' PRCPLG-A-4 129 5 PRCPLG-5 550 6.080' 8 1.4063" 1.8400' 5.3907' PRCPLG-AL-5 0155 6' PRCPLG-6 884 7.280' 8 1.5125' 1.9462' 6.4461' PRCPLG-AL-6 Couplings are straight lapped. APPROVAL STAMP Tolerance, thread length =±1 thread. Plus or minus I turn is the maximum variation permitted from the gauging face of the working thread gauges. This Is equivalent to plus or minus 1 and 1-1/2 turns from the basic dimensions, since the variation of plus or mInus 1/2 turn from basic dimension is permitted In working gauges. 1100 Us Highway 271 South • Gilmer, TX 75644 6 Phone: 903/843-5591 • wwwff.om Return To Index BOND EDH2OT CAST DEVICE BOXES PrintThis Page PLAST FS/FD Series Dimensions FS/FD Single Gang Dimensional Drawings FSIFD 2 Gang Dimensional Drawings t a a--a. T015 Of I ill mounting ledge Top of mounting APPROVAL STAMP ledge 7. FSIFD Series Configurations All configurations offered In both PS or P0 lax depths. FS pratix: Shallow configuration. FD pretho Deep configuration 0 0 0 0 0 .0 __ EI 0 ID FS1FD FSR/FDR FSL/FDL FSCJFDG (Single gang) 0 FSCTIFDCT LIJR FSCC/FDCC UH FS/Fl) (Two Gang) 1100 us Highway 271 South • Gilmer, TX 75644 15 Phone: 903/843-5591 • www.stibojd.com a Return To Index PLASTBO11D REDH20T CAST DEVICE BOXES Print This Page FS/FD Series Technical Data --------------- FS SERIES (SHAUOWBOX) -SINGLE GANG DEAD END Pipe FERROUS Nominal ALUMINUM Size CAThIOG # Weight A B C U CATALOG # 01/2' PRFS1 3.2 1.38 1.92 1.69 0.67 PRFSISA 03/4' PRFS2 3.3 1.63 1.92 1.69 0.79 PRFS2SA Dl' PRFS3 3.5 2.00 1.92 1.69 0.92 - FS SERIES (SHALLOWBOX) - TWO GANG DEAD END Pipe FERROUS Nominal ALUMINUM Size CATALOG H Weight A B C D CATALOGH £11/2' PRFS12 3.3 1.38 1.92 1.69 0.67 PRFS12SA [13/4' PRFS22 3.4 1.63 1.92 1.69 0.79 PRFS22SA Dr PRFS32 3.6 2.00 1.92 1.69 0.92 - FD SERIES (MW BW() - SINGLE GANG DEAD END Pipe FERROUS Nominal ALUMINUM Size CATALOG H Weight A B C I) CATALOG H 01,2' PRFD1 2.7 1.38 1.92 2.69 .67 PRF01SA 03/4' PRFD2 2.8 1.63 1.92 2.69 0.79 PRFD2SA Di- PRFD3 3.1 2.00 1.92 2.69 0.92 PRF03SA FDL SERIES Pipe Nominal Size CATALOG H Weight A B C I) 01/2' PRFDL1 3.1 1.38 1.92 2.69 0.67 03/4' PRFDL2 3.3 1.63 1.92 2.69 0.79 FDR SERIES Pipe Nominal Size CATALOG U Weight A B C I) R1/2' PRFDR1 3.2 1.38 1.92 2.69 0.67 3/4' PRFDR2 3.3 1.63 1.92 2.69 0.79 FSCA SERIES Pipe Nominal Size CATALOG U Weight A B C I) 01/2' PRFSCA1 2.5 1.38 1.92 1.69 0.67. 0314 PRFSCA2 3.5 1.63 1.92 1.69 0.79 FSCT SERIES Pipe Nominal Size CATALOG# Weight A B C U D1/2" PRFSCT1 2.2 1.38 1.92 1.69 0.67 i' PRFSCT2 2.5 1.63 1.92 1.69 0.79 Di PRFSCT3 2.8 2.00 1.92 1.69 0.79 MCC SERIES Pipe Nominal Size CATALOGH Weight A B C D 01/2' PRFSCC1 2.0 1.38 1.92 1.69 0.67 03/4' PRFSCC2 2.2 1.63 1.92 1.69 0.79 FSC SERIES (SHALLOW BOX) - SINGLE GANG THROUGH FEED Pipe FERROUS Nominal ALUMINUM Size CATALOG # Weight A B C D CATALOG H 01/2' PRFSCI 2.2 1.38 1.92 1.69 0.67 PRFSC1SA 03(4' PRFSC2 2.4 1.63 1.92 1.69 0.79 PRFSC2SA O 1' PRFSc3 2.7 2.00 1.92 1.69 0.92 - FSC SERIES (SHALLOW BOX) - TWO GANG THROUGH FEED PIpe FERROUS Nominal ALUMINUM Size CATALOG H Weight A B C D CATALOG H fl1/2' PRFSC12 3.3 1.38 1.92 1.69 0.67 - 03/4' PRFSC222 3.6 1.63 1.92 1.69 0.79 - Dr PRFSC32 4.0 2.00 1.92 1.69 0.92 - PVC SERIES (DEEP BOX) - SINGLE GANG THROUGH FEED Pine FERROUS St CATALOG H Nominal ALUMINUM Weight A B C B CATALOG H D1/2 PRFDC1 2.7 1.38 1.92 2.69 0.67 PRFDC1SA 03/4' PRFDC2 2.8 1.63 1.92 2.69 0.79 PRFDC2SA Dr PRFDC3 3.1 2.00 1.92 2.69 0.92 PRFDC3SA FSD SERIES Pipe Nominal Size CATA1.OG# Weight A B C D PRFSD212 2.5 1.63 1.92 1.69 .79 FSL SERIES Pipe Nominal Size CATALOG H Weight A B C 0 01/2' PRFSL1 2.5 1.38 1.92 1.69 0.67 03/4 PRFSL2 2.7 1.63 1.92 1.69 0.79 FSR SERIES PIne Nominal She CATALOG If Weight A B C Ii 01/7 PRFSR1 2.0 1.38 1.92 1.69 0.67 03/4 PRFSR2 2.2 1.63 1.92 1.69 0.79 FDCT SERIES Pipe Nominal Size CATALOG H Weight A B C D 01/2' PRFDCT1 3.1 1.38 1.92 2.69 0.67 03/4 PRFDCT2 3.4 1.63 1.92 2.69 0.79 Di' PRFDCT3 3.9 2.00 1.92 2.69 0.92 APPROVAL STAMP 1100 us Highway 271 South • Gilmer, TX 75644 16 Phone: 903/843-5591 9 www.rjIgQn.cm LR FORM 8 Pipe FERROUS Nominal ALUMINUM size CATALOG #Weight A BCD E CATALOG # [:1117 PRHLR18 1.4 5.48 1.48 2.20 1.00 3.31 PRLR19 [13/4* PRHLR28 2.1 6.35 1.73 2.35 1.19 3.94 PRLR29 El i" PRHLR38 2.8 7.51 1.98 2.67 1.38 4.56 PRLR39 1-1/4" PRHLR448 4.5 8.82 2.42 3.20 1.75 5.31 PRLR49 1-1/2 PRHIR58 6.2 10.67 2.82 4.04 2.13 6.50 PRLR59 2" PRHLR68 10.7 13.04 3.60 5.04 3.00 8.56 PRLR69 2-1/2" PRLR78 17.7 15.98 4.48 6.73 4.25 10.88 PRLR789 O 3" PRLRB88 18.0 15.98 4.85 6.73 4.25 10.88 PRLRS89 3-1/2" PRLR989 21.0 14.73 4.92 6.98 4.50 10.25 PRLR989 U 4 PRLR1089 24.0 14.73 5.42 6.98 4.50 10.25 PRLRIO89 LR FORM 7 Pipe FERROUS Nominal ALUMINUM SizeCATALOG # Weight ABCDECATALOG # El 1/2" PRLR17 1.2 5.10 1.42 2.29 0.94 3.19 PRLR17SA i" PRLR27 1.6 5.98 1.67 2.48 1.13 3.81 PRLR27SA i" PRLR37 2.1 7.04 1.92 2.79 1.38 4.50 PRLR37SA El 1-1/4" PRLR47 3.0 7.79 2.35 3.23 1.75 5.00 PRLR47SA El 1-1/2" PRLR57 4.1 8.67 2.60 3.60 1.94 5.44 PRLR57SA 2' PRLR67 5.7 10.17 3.17 4.17 2.44 6.38 PRLR67SA 2-1/2' PRLR777 10.0 12.54 3.67 5.79 3.56 8.38 PRLR777SA Q ' PRLR87 12.7 12.54 4.42 5.79 3.56 8.38 PRLR87SA U 3-1/2' PRLR97 19.0 14.73 4.92 6.98 4.50 10.25 PRLR97SA o PRLRI07 19.0 14.73 5.42 6.98 4.50 10.25 PRLR107SA APPROVAL STAMP Return To Index Print This Page PLASThIOND REDH2OT CONDUIT BODIES Conduit Bodies Technical Data - PRT27 Form & Form 7 Covers I' a D - TBFORM8 MARK9 lB FORM 7 Pipe FERROUS Nominal ALUMINUM Pipe FERROUS Nominal ALUMINUM Size _CATAL0G#ht AD E CATALOG fl Size CATALOG# Weight A .B O 1/2' PRF11B18 2.0 6.69 3.57 1.46 1.00 3.31 PRTB19 fl 1/2" PRTB17 1.6 6.63 2.67 1.64 0.94 3.19 PRTB19 i' PRUTB28 .2.3 7.78 3.79 1.64 1.19 3.94 PRTB29 171 3/4' PRTB27 2.1 7.75 2.92 1.83 1.13 3.81 PRTB29 r PRHTB3S 3.1 9.31 4.17 1.83 1.38 4.56 PRTB39 9 1" PRTB37 2.7 9.25 3.29 2.05 1.38 4.50 PRT839 1-114" PRHT8448 5.2 11.00 4.38 2.27 1.75 5.31 - 0 1-1/4" PRTB47 3.7 9.94 3.35 2.27 1.75 5.00 - 1-1/2' PRHT858 7.0 13.38 5.07 2.83 2.13 6.50 - 0 1-1/2" PRT057 4.7 11.19 5.04 2.52 1.94 5.44 - 2' PRHTB68 no 16.25 5.85 3.83 3.00 8.56 - 0 2" PRTB67 7.0 13.19 6.17 3.08 2.44 6.38 - 1100 us Highway 271 South • Gilmer, TX 75644 9 Phone: 903/843-5591 • www.plastibond.com ITEM I LLFORM8 MARK9 Pipe FERROUS Nominal ALUMINUM Size CATALOG U Weight A B C D F CATALOGS 0112° PRHLL18 1.4 5.46 1.48 2.20 1.00 3.31 PRLL19 O We PRHLL28 2.1 6.35 1.73 2.35 1.19 3.94 PRLL29 Or PRHLL38 2.6 7.51 1.98 2.67 1.38 4.56 PRLL39 9 1-1/4' PRHLL448 4.2 8.82 2.42 3.20 1.75 5.31 PRLL49 01-1/2° PRHLL58 6.2 10.67 2.82 4.04 2.13 6.50 PRLL59 PRHLL68 10.5 13.04 3.60 5.04 3.00 8.56 PRLL69 02-1/2° PRLL78 19.0 15.98 4.48 6.73 4.25 10.88 PRLL789 PRLL888 21.5 15.98 4.85 6.73 4.25 10.88 PRLL889 03-1/2° PRLL98 21.5 14.73 4.92 6.98 4.50 10.25 PRLL989 94' PRLL1089 24.5 14.73 5.42 6.98 4.50 10.25 PRLL1089 LL FORM 7 Pipe FERROUS Nominal ALUMINUM Size CATALOGS Weight A B C B F CATALOGS 01/2° PRLL17 1.2 5.1 1.42 2.29 0.94 3.19 PRLL17SA 0314° PRLL27 1.6 5.98 1.67 2.48 1.13 3.81 PRLL27SA Di' PRLL37 2.1 7.04 1.92 2.79 1.38 4.50 PRLL37SA Ell-1/4, PRLL47 3.0 7.79 2.35 3.23 1.75 5.00 PRLL47SA O 1-1/2° PRLL57 4.1 8.67 2.60 3.60 1.94 5.44 PRLL57SA 02' PRLL67 5.7 10.17 3.17 4.17 2.44 6.38 PRLL67SA 2-112° PR1L777 10.0 12.54 3.67 5.79 3.56 8.38 PRLL777SA 03° PRLL87 12.7 12.54 4.42 5.79 3.56 8.38 PRLL87SA 3-1/2' PRIL97 19.0 14.73 4.92 6.98 4.50 10.25 PRLL97SA 94' PRLLI07 19.0 14.73 5.42 6.98 4.50 10.25 PRLLI07SA APPROVAL STAMP Return To index Print This Page Conduit Bodies Technical Data LB FORM 8 MARK 9 Pipe FERROUS Nominal ALUMINUM Size CATALOG S Weight A B C D E CATALOG S 9 1I2 PRHLB18 1.5 5.48 2.26 1.42 1.00 3.31 PRL819 3/4° PRHLB28 2.0 6.35 2.48 1.60 1.19 3.94 PRLB29 Dr PRHLB38 2.9 7.51 2.85 1.79 1.38 4.56 PRLB39 D1-1/4 PRHLB448 4.1 8.82 3.38 2.23 1.75 5.31 PRLB49 D1-112° PRHLB58 6.5 10.67 4.07 2.79 2.13 6.50 PRI.B59 D 02° PRHLBGS 8.2 13.04 4.85 3.79 3.00 8.56 PRLU69 02-1/2° PRLB78 18.2 15.98 6.17 5.04 4.25 10.88 PRL8789 03 PRLB888 21.2 15.98 6.54 5.04 4.25 10.88 PRL8889 03-1,2° PRLB98 31.2 18.92 7.60 6.29 5.44 13.44 PRLB989 94 PRLB108 32.0 18.92 7.85 6.29 5.44 13.44 PR181089 LBFORM7 - Pipe FERROUS Nominal ALUMINUM Size CATALOG U Weight. A_ _j C D E CATALOG S 01/7 PRLB17 1.1 5.10 2.29 1.42 0.94 3.19 PRLB17SA 3/4° PRLB27 1.7 5.98 2.54 1.6 1.13 3.81 PRL827SA 01° PRLB37 2.2 7.04 2.92 1.79 1.38 4.50 PRLB37SA 01-1/4° PRLB47 3.1 7.79 3.35 2.23 1.75 5.00 PRLB47SA O 1-12° PRLB57 3.8 0.67 3.73 2.48 1.94 5.44 PRL857SA 02° PR1667 5.2 10.17 4.29 3.04 2.44 6.38 PRLB678A 02-112° PR18777 10.0 12.54 5.17 4.29 3.56 8.38 PRL8777SA 93 PR1887 13.0 12.54 5.92 4.29 3.56 8.38 PRLB87SA 03-11z PRLB97 19.0 14.73 6.60 5.29 4.50 10.25 PRLB97SA 04' PRL8107 18.5 14.73 7.10 5.29 4.50 10.25 PRLB107SA 1100 US Highway 271 South 'Gilnier, TX 75644 Phone: 903/843-5591 a 20 roil gray PVC exterior coating 10 trade sizes from 1/2" through 4". CONDUIT CLAMP BACKSPACER Pipe FERROUS Nominal WL Size - Catalog I Each 0 1/2' PBCLB-M50 0.1 III 3/4" PBCLB-M75 0.1 D v PBCLB-M100 0.1 1-1/4' PBCLB-M125 02 1-1/2" PBCLB-M150 0.2 D 2' PBCLB-M200 0.3 2-1/2" PBCLB-M250 1.0 " PBCLB-M300 1.7 " PBCLB-M400 2.0 4j% - CONDUiT PIPE STRAP 2 HOLE Pipe FERROUS Nominal Wt. Size Catalog U For 100 o 1/2" PBPS11S-2 2.0 o i" PBPS22S-2 3.0 o i" PBPS33S-2 4.0 El 1-1/4' PBPS44S-2 4.5 El 1-1/2" PBPS55S-2 5.0 o P8PS66S-2 10.0 O 2-1/7 PBPS776-2 13.0 El PBPS88S2 17.0 0 3-1/7 PBPS99S-2 20.0 LI PBP8100S-2 25.0 PBGHS Style Return To Index PLASTIBOND REDH2OT SUPPORT PRODUCTS - Print This Page Pipe Straps and Clamp Back Spacers Specifications PP F PLASThBOND PVC coated pipe straps are used to securely mount conduit to a wall or other structure for support. They are available In two styles: a one-hole malleable iron strap or a two-hole stamped steel strap. Mounting hardware not provided. PI.ASTIBOND PVC coated clamp back spacers are used with malleable or stamped pipe straps to provide a mounting stand-off for a conduit from a wail or other structure. Flivi K-,9= CONDUIT PIPE STRAP 1 HOLE SETS Pipe FERROUS Nominal WL Size Catalog I FarlOO 1/2 PBPS11M 11 J 3/4" PBPS22M 14 1' PBPS33M 12 U 1-1/4' PBPS44M 25 O 1-1/2" PBPS55M 36 2" PBP866M 71 2-1/2" PBPS77M 111 3" PRPS88M 134 3-1/2" P8PS99M 166 4 PBPS100M 256 IONDOff HAi'IGER Pipe Nominal SIze -. Catalog # Weight - 1/2' PB6HOB 0.1 i" PB6H1B 0.1 D i" PB6H2B 0.1 D 1-1/4" PB6H313 0.1 D 1-1/7 PB6H413 0.2 D 2" P1361-1513 0.3 2-1/2' PB6H6B 0.4 El PB61-1713 0.5 113-1/7 PB61-1811 0.6 4" P86H9B 0.7 PLASTI-BOND PVC coated conduit clamp hangers are used with threaded rod to securely suspend conduit runs supported from above. They are provided with stainless steel hardware. FEATURES 20 mill gray PVC exterior coating 10 trade sizes from 1/2" through 4". 1JI[i%IIl1t II THREW RODS PLASTI-BOND PVC coated all thread rod is used with coated conduit hangers and coated size ....................Catalog # strut to securely suspend conduit runs supported from above. It is provided in 3/8" and 0 3/8'X 3' PBH193-318X3 1/2" sizes and three standard lengths, 3,6' and 10'. . 0 3/8'X 6' PBH193-3/8X6 _____________________ • - 0 3/5 X 10' P1311193-3/8X10 FEATURES .0 117X3' PBH193-1/2X3 0 1/2" X 6' PB14193-1/2X6 20 mil gray PVC exterior coating PBH193 0 1/2' X 10' PBH193-1/2X10 2 trade sizes and 3 standard lengths APPROVAL STAMP 1100 US Highway 271 South • Gilmer, TX 75644 34 Phone: 903/843-5591 • wwwflI4jom \ \\ L \ \\ TN - a StrutSystems - Qhnne1s, Hardware Fittings, Mechanica' & Electrical Accessories, - SpecaLMaterial(Alurninum, Stainless Steel, TOPrglass), Mini Chanr,eLO6hcrete lnserts, Slotted Arigle, KwikWiréTM, -SS-O9 Dura-BlokT-Suppprts, Oura GleanTM Waslidown Supports : ci - •'5_ - •--- .z__ - - -r- - - - - k 3 ,--- • -, -- - -L-i: - -- - - -_; - -:' Channel B-Line's metal framing channel is cold formed on our modem rolling mills from 12 Ga. (2.6mm), 14 Ga. (1.9mm), and 16 Ga. (13mm) low carbon steel strips. A continuous slot with intumed lips provides the ability to make attachments at any point. Lengths Standard lengths are 10' (3.05m) and 20' (6.09m) with length tolerance of ±1/8" (+3.2mm). Custom lengths are available upon request. Slots B-Line's slotted series of channels offer full flexibility. A variety of pre-punched slot patterns eliminate the need for precise field measuring for hole locations. Slots offer wide adjustments in the alignment and bolt sizing. Holes A variety of pre-punched /I6" (14.3 mm) diameter hole patterns are available in B-Line channels. These hole patterns provide an economical alternative to costly field drilling required for many applications. Knockouts When used with series B217-20 Closure Strips, B-Line's knockout channels can be used to provide an economical U.L. listed surface raceway. Channels are furnished with 7/8" (22.2 mm) knockouts on 6" (152 mm) centers, allowing for perfect fixture alignment on spans up to 20' (6.09 in). Materials & Finishes (Unless otherwise noted) Steel: Plain 12 Ga. (2.6), 14 Ga. (1.9) and 16 Ga. (1.5) Steel: Pre-galvanized 12 Ga. (2.6), 14 Ga. (1.9) and 16 Ga. (1.5) Finish Code Finish Specification PLN Plain ASTMA10I1, 33,009 PSI min. yield GRN Dura-Green GAIN Pre-Galvanized ASTMA6S3 33,000 PSI min. yield KDG Hat-Dipped Galvanized ASTMA123 YZN Yellow Zinc Chromate ASTM 8633 SO Type II SS4 Stainless Steel Type 304 ASTMA240 SS6 Stainless Steel Type 316 ASTM A240 AL Aluminum Aluminum 6063-T6 Note: A minimum order may apply on special material and finishes. Design Load The design loads given for strut beam loads are based on a simple beam condition using an allowable stress of 25,000 psi. This allowable stress results in a safety factor of 1.68. This is based upon virgin steel minimum yield strength o133,000 psi cold worked during rolling to an average yield stress of 42,000 psi. Welding Weld spacing is maintained between 21h inches (63.5 mm) and 4 inches (101.6 mm) on center. Through high quality control testing of welded channels and continuous monitoring of welding equipment, B-Line provides the most consistent combination channels available today. Metric Metric dimensions are shown in parentheses. Unless noted, all metric dimensions are in millimeters. ITEM J SELECTION CHART for Channels, Materials and Hole Patterns EMU AW U. B22 1/s" (41.3) lIs" (41.3) 12 Ga. .105 12 Ga. 120a. 124 13 121 1. 12 ainz M mom B26 1I" (41.3) iir (41.3) 16 Ga. B42 1" (25.4) P/a" (41.3) 1 12 Ga. - 12 Ga. ; 1154 131W (20.6) 151C 413) 14 Ga. .080 14 Ga. 14 Ga. 1214 1 1214 - 12 B62 13/16" (20.6) 13,16" (20.6) ffi9 E7016 3/4" (19.0) 5/g" (15.9) 16 Ga. - - - - - - - - The selection has been prepared to provide a reference for available channel, materials and hole patterns. Material types available for various hole patterns are defined by numbers I thru 4. Some stainless steel channels with hole patterns arc available on special order only. *Metric equivalent for thicknesses shown in chart. I- Steel 12 Ga. =2.6mm 18 Ga. =1.2nim 2-Ahuninum 14 Ca. = 1.9 nun .105 =2.6mm 3-Type 304 Stainless Steel 16 Ga. = 1.5 nun .080=2.0mm 4 -Type 316 Stainless Steel Properties may vary due to commercial tolerances of the material Channel Part Numbering Example: Channel Type Hole Patterns Material(Finisli Length Bil SH(pg40) GRN 120 B12 S(pg.40) GALV 240 B22 H178tpg.40) HDG B24 TH(p&41) YZN B26 K06(pg.41) SS4 B32 SHA(p&41) SS6 B42 S58 (pg. 42) AL 1152 t M (pg.42) 1154t H25pg.43) B56 H112t(pg.42) B62 * Leave blank for no hole pattern B72 137016 t BK style channel available in four (4) channel sizes and one (1) hole pattern only. (Example BK22H 112) Reference page 14 for general fitting and standard finish specifications. COOPER B-Line ITEM J / Hex Bolt Size as Listed Bolt Size F lole )iarneter E Notes: Hanger Rod Suspended Plastic Coated hanger is available ('N" Suffix). Please contact factoryfor additional Information. Maximum operating temperature is 300°F Minimum safety faster of We (5) on ultimate land. PIPE & CONDUIT CLAMPS Finish: Eleciro.galvanized Order By: No., and Finish POWER-STRUT" I iik;L. Note: For EMT larger than Design Load 2' use PS 1100 EIl Size Stock Thickness Hanging Load Rating/lbs. WtJ100 pCS W .060 400 11 12 .075 600 15 18 1W .106 800 29 33 Nominal Size Fits OS]. Stock Thickness Hanging Load Rating/lbs. Wt./100 poe W 0.708-0.840 .060 250 10 :Ve 0.922-1.050 .060 1.163-1.315 400 11 1' 12 11/4' 1.510-1.660 .075 400 18 11& 1.740-1.900 .075 500 20 2' 2.197-2.375 '-'- - .. I •. Design Load Material and finish are specified as: --•.-_L 1100 AL Alum, clamp, [6 fasteners 1100 HG Clamp, Stainless Steel fasteners 1116 Alum. clamp and fasteners . 1117 Alum. clamp, Stainless Steel fasteners IlOUSS Stainless Steel clamp and fasteners.—' Pipe Size Stock Stock Thickness Hanging Load Rating/lbs. Wt4100 pcs w .060 400 10 w 11 Ile ___ .075 600 15 17 1~' 19 1W .105 800 29 34 2W 40 47 3W .125 1.000 62 67 80 IF .135 . 102 8. 130 ., 143 12' i 174 Conduit Size I A Rod Size B C D E F I Load Rating/lbs. Wt./100 PCs 1h A 25A 1 2 2%_ 1/4 x 214 400 20 A 2A 21 1 3 2% 1/32 '/ix2 24 114 3'A r24 Vix2% 27 1% 3% '/ix3 29 2 35/4 1¼ 25A '/ x 3% 33 21h 41A 1¼ 3% 146 3Ax414 800 71 I" 47A 4 %x5 78 3¼ 51A 4% %x6 85 4 % ______ 6% 5% 178 5 6% 53/4 %x7¼ 199 _5_ V4 714 114 61A %x8% 1,000 231 _8_ % 9% 114 8 %xlo 1.200 449 Power Struta Engineering Catalog 43,5 Kwik Bolt 3 Expansion Anchor 4.35.1 Product Description The Kwik Bolt 3 (KB3) is a torque Product Features 4.3.5.1 Product Description 4.3.5.2 Material Specifications 4.3.5.3 Technical Data 4.35.4 Installation Instructions 4.33.5 Ordering Information Impact Section (Dog Point) A Nut— Washer-4-. AnchoL' Thread Anchor Body 4 Expansion Sleeve— .. (Wedges) Expansion Cone Ustinos/ADnrovals lCC-.ES (International Code Council) ESR-1385 Seismically recognized under ACO1 dated April 2002 City of Los Angeles (COLA) Underwriters Laboratories (UL) UL (Underwriters Laboratories) UL 203 Pipe Hanger Equipment for Fire Protection Services (3/6' -314') Factory Mutual (F Pipe Hanger Components for Automatic Sprinkler (3/8' - 3/4) -- Miami-Dade County NOA No. 06-0810.13 Qualified under an NQA-1 Nuclea'a1( Program 'Please icier to the reports to vecify that the type and dlmnetaz saccilied is Included controlled expansion anchor, which provides consistent performance for a wide range of mechanical anchor applications. This anchor series is available in carbon steel with zinc electroplated coating, carbon steel with hot-dip galvanized coating, 304 stainless steel and 316 stainless steel versions.The threaded stud version of the anchor is available In a variety of diameters ranging from 1/4 in. to 1 in. depending on the steel and coating type. Applicable base materials include normalweight concrete, structural lightweight concrete, lightweight concrete over metal deck, and grout filled concrete masonry. Guide Specifications Torque controlled expansion anchors shall be Kwik Bolt 3 supplied by Huh meeting the description in Federal specification A-A 1023A, Type 4. The anchor bears a length identification mark embossed into the impact section (dog point) of the anchor identifying the anchor as a Hilti Kwik Bolt 3 in the installed condition. Anchors are manufactured to meet one of the following conditions: The carbon steel anchor body, nut and washer have an electro- plated zinc coating conforming to ASTM B 633 to a minimum thickness of 5 tim. The carbon steel hot-dip galva- nized anchor body, nut, and washer conform to ASTM A 153, The stainless steel expansion elements conform to either AISI 304 or AISI 316. The stainless steel anchor body. nut, and washer conform to AISI 304. The stainless steel expansion elements coni to either AISI 304or S13 The stainless steel anchor body, nut, and washer conform to AISI 316, The stainless steel expansion elements conform to AISI 316. Length identification code facili- tates quality control and inspection after installation. Through fixture installation and variable thread lengths Improve productivity and accommodate various base plate thicknesses. Raised impact section (Dog Point) prevents thread damage during installation. Anchor size Is same as drill bit size for easy installation. For temporary applications anchors may be driven into drilled holes after usage. Mechanical expansion allows Immediate load application. Installation Drill hole in concrete, structural lightweight concrete, or grout filled concrete masonry using a Hull carbide tipped drill bit and a Hilti rotary hammer drill. Remove dust from the hole with oil free compressed air or vacuum. Alternately for 1/2, 5/8, 314, and 1 inch diameter Kwik Bolt 3 anchors, the hole may be drilled using a matched tolerance Hilti DD-C wet diamond core bit for anchoring applications. The slurry must be flushed from the diamond cored hole prior to anchor installation. The minimum hole depth must exceed the anchor embedment prior to torquing by one hole, diameter. Drive the anchor into the hole using a hammer. A minimum of six threads must be below the surface of the fixture, lighten the nut to the recommended installation torque. 224 Hilt. Inc. (US 1-5OO879-81OU 1 wwwuei.illLcom I en snp.lm 1-FM-8-9-.T"* I lift. 'cau4 Corp. 1-5o.383-458 I www.ca.hilti.com I Kwik Bolt 3 Expansion Anchor 4.3.5 4.3.5.2 Material Specifications Carbon steel with electroplated zinc All Carbon Steel Kwik Bolt 3, Long Thread Kwik Bolt 3 and Rod Coupling Anchors, excluding the 3/4 x 12 and 1 inch diameter sizes, have the minimum tensile bolt fracture loads shown in Table 1. All carbon steel 3/4 x 12 and 1 inch diameter sizes and carbon steel countersunk Kwik Bolt 3 anchor bodies have mechanical properties as listed in Table 1. Carbon steel anchor components plated in accordance with ASTM B 633 to a minimum thickness of 5 pm. - Nuts conform to the requirements of ASTM A 563, Grade A, Hex. Washers meet the requirements of ASTM F 844. Expansion elements (wedges) are manufactured from carbon steel, except the following anchors have stainless steel wedges: All 1/4 Inch diameter anchors K83 314x12 All 1 inch diameter anchors All countersunk Kwik Bolt 3 Carbon steel with hot-dip galvanized coating Anchor bodies manufactured from carbon steel have the minimum tensile bolt fracture loads shown In Table 1. Carbon steel anchor components hot-dip galvanized according to ASTM A 153, Class C (43 pm mm.). -- Nuts conform to the requirements of ASTM A 563, Grade A, Hex. - Washers meet the requirements of ASTM F 844. Stainless steel expansion elements (wedges) are manufactured from either AISl 304 or AlSI 316. Stainless steel 4- Anchor bodies smaller than 314 inch, excluding all Countersunk Kwik Bolt 3 anchors, are produced from AlSl 304 00 stainless steel having the minimum bolt fracture loads shown In Table 1. Anchor bodies 3/4 inch and larger, and all stainless steel Countersunk Kwik Bolt 3 anchor bodies, are produced from AISi 304 or 316 stainless steel have the minimum mechanical properties shown in Tablet Nuts meet the dimensional requirements of ASTM F 594. Washers meet the dimensional reqi.thements of ANSI B18.22.1, Type A. plain. Stainless steel expansion elements for AlSI 304 anchors are made from either AlSl 304 or AlSI 318. Stainless steel expansion elements For AISl 316 anchors are made from AlSI 316. All stainless steel nuts and washers for AlSl 304 and 316 anchors are manufactured from AISl 304 and 316, respectively. Combined Shear and Tension Loading Nd 5.4 \. (. \' 1.0 (Ref. Section 4.1.8.3) N,,) 'rc' HJ',.Ia (US, %-8OQ-89-000 1 www.us.biltLcørn I en epaoI -5C?-879-SOO I I10 Ca.Co!p. '-8 -383-4•5e I www.ca.hllti.com I Prcd..v 2