Loading...
HomeMy WebLinkAbout6106 AVENIDA ENCINAS; ; FA050007City of Carlsbad Fire Alarm Permit Permit No: FA050007 6106 AVENIDA Job Address: Status: ISSUED ENCINAS Permit Type: FALARM Applied 2122/2005 Parcel No: 2110302500 Approved: 3/2/2005 Lot #: 0 Reference No.: Issued: 3/2/2005 PC #: Inspector: Project Title: MC WIN CORP. FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: Owner: MCWIN CORP 6102 AVENIDA ENCINAS #B CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 105 0 105 0 ~Apls-vq Mc WIN CORP. 6106 AVENIDA ENCINAS CARLSBAD, CA. FIRE ALARM SUBMITTAL CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions In correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to or a the violation of any law. fly________________ Date Submitted By: AM 3830 Calle Fortunada San Diego, CA 92123 (858) 654-3173 C-10 # 707408 Contact: STACEY TESCIER Mc WIN CORP. FIRE ALARM SUBMITTAL OTY DESCRIPTION MODEL # MANF. CSFM# 1 FIRE ALARM CONTROL PANEL FOCUS CADET ADT/ADEMCO 7165-0078:197 I FIRE ALARM ANNUNCIATOR 741210 ADT/ADEMCO 7165-0078:197 3 INPUT (SIM) MODULES 472366 ADT/ADEMCO 7165-0078:197 I SMOKE DETECTOR 429CAD ESL 7272-0447:128 I MANUAL PULL STATION ADT-BG-12L ADT 7150-7150:178 HORN/STROBE ISCD P1224-MCW SYS SENSOR 7135-1209:223 CONNECTION TO EXISTING WATERFLOW SWITCH CONNECTION TO EXISTING BACKFLOW SWITCH LOT 18/2 FIRE CABLE 740132 ADTIPAIGE/GENISIS 7161-1487:100 LOT 14/2 FIRE CABLE 740133 ADT/PAIGE/GENISIS 7161-1487:100 LOT 18/4 FIRE CABLE 740134 ADTIPAIGE/GENISIS 7161-1487:100 S789 (FOCUSCADET) Operating Panel At y, II 6io1II Ifr ! 00 ölli __ OOOjII FOCUS® CADET A UL Listed Commercial Fire/Burglar and Access Control Security System GENERAL The ADT FOCUS CADET is an economical, user-friendly, programmable, electronic security system that links a facilities detectors with a single microprocessor-based control unit. The FOCUS CADET allows you to control hundreds of critical fire and security functions from one menu-driven interface as simple to use as the automated teller machine (ATM) at your local bank. FEATURES Control of up to 64 input/output protection points in as many as four independent groups from one central location. 1 built-in supervised bell outputs for compliance with local FA requirements as well as for use with BA applications. Up to 32 2-wire smoke detectors. Built in 4-wire smoke detector power reset. Up to 4 BA partitions. 8 built-in points including two 2-wire smoke detector loops. An RS485 bus employed for communicating and powering the gateways, operation panels, printer interface units, and sensors via gateways. The R5485 bus can handle a 4000ft wire run (which can be extended to 8000ft max. with a repeater). Built—in SIM gateway that serves as interfaces for sensors, output devices and wired expansion modules. A built-in communicator and support for an optional backup dialer for monitoring purposes to a Customer Monitoring Center. Ability to download the programming from a remote location using the ADEMCO Compass Downloader. Programmable scheduling of events to automatically occur at a specific time of day. Manual activation and deactivation of any function. Ability to bypass points for maintenance or service. Up to 99 individual operating panel users, each having unique security privileges. Up to 255 individual card/key reader users, each having unique levels of access. Up to 4 door access control readers. Continuous supervision and identification of faults associated with low battery voltage, AC power and internal or external communication. Capability of employing up to 8 operating panels, with a single operating panel controlling all BA groups. Ability to program automatic activation/deactivation of security groups. A real-time clock for keeping track of time, day of week and date. Control and recording of employee access to workplace areas along with time and date. History file with 512-event capacity. Supports a hard-copy printer to be connected via printer interface units. 2 built-in output triggers. Provisions for customer to remotely test motion detection sensors vault sensors, BA groups and connected bells, eliminating the need for walk tests. Built-in low battery cut-off. Capable of wireless expansion for quick keys, panic buttons and money clips. Self-test of control unit upon power up. Built-in auxiliary relay interface, which can be set for 4-wire smoke detector reset operation. Agency Listings The FOCUS CADET system complies with UL609, UL611, UL864, UL985, UL1023, UL1610, UL1635, NFPA71 and NFPA72. This document is not intended to be used for installation purposes. We try to keep our product information up to date and accurate. We cannot cover all specific application or anticipate all requirements. AU specifications are subject to change without notice. For more information, contact: ADT Security Services Inc. P.O. Box 5035, Boca Raton, FL 33431 Toll Free: 1-877-962-5208 "Demand the Best, Prevent the Worst"sm /=&, Mi I - SPECIFICATIONS Input power: 120VAC,. 50/60Hz Output power: 18V, 60Hz, 50VA (1.5A) or 72VA (1.5A) Standby Battery: 12VDC Sealed Lead-acid battery Float Charging Voltage to battery: 13.65VDC Battery charger range: 7 AH - 24 AH with 50VA transformer / 7 AH - 34.4 AH with 72VA transformer Low battery Signal: 12VDC Low battery Cutoff: 9.8VDC Aux. Power #2: 12VDC, 1 0Amp max. (PTC protected) Notification Circuits (BELL 1): 12VDC, 1.7 AMP Max. (Style Y)(PTC Protected) AUX Relay output: Dry contact rating: 28V, 2 AMP max. resistive load Wet:12VDC, 1.7AMP max. Current Draw: Standby 300mA Alarm 440mA Temperature Range: 32F (OC) to 120F (49C) COMMUNICATION FORMAT Contact ID CABINET SPECIFICATIONS 18" H x 14-1/2" W x 4.3" D SYSTEM CAPACITY Total programmable input/output points: 64 Operating Panels: 8 Notification Bell Circuits: 1 Number of users: 255 First 99 may be ID codes and/or card keys Remaining are card/key users only Partitions: 4 History Log: 512 events COMPATIBLE DEVICES, RS-485 BUS 471210: Operating Panel (Interactive Keypad) 472490: RF Gateway 471715: Printer Interface Unit 472270: Access Control Interface Unit 472430: RS-485 Repeater PRODUCT LINE INFORMATION 472511: Main Control Unit. Consists of: A steel cabinet with key locked front cover Plug in transformer (18VAC/50VA) 472514: Main Control Unit. Consists of: A UL steel cabinet with key locked front cover Plug in transformer (ISVAC/5OVA) 472450: Assault Sensor /Required if the control unit is mounted outside of a protected area. 472404: 18VAC/72VA wired in transformer /May be required for some commercial installations. 248222: Wire Lead Kit for Batteries. 472402A: Backup Dialer 477967: Battery, 12-:Volt 7.OAH Sealed Lead-Acid SIM TRUNK DEVICES 472366: Sensor Interface Module (SIM) /Used for interfacing sensors not already equipped with a SIM. 472370: SIM FA Pull Station I Manual Fire-Alarm Pull Box. 472374: SIM Holdup Alarm Switch / A finger-operated holdup device. 472488: Supervised Horn/Strobe. SIM for interfacing various types of horn/strobes that are not already equipped with a SIM (use with P1215 Horn Strobe or any other ADT approved indicating device). 633SlM: SIM Long Range. PIR (80'x80' 200ft long range) 45051M: SIM PIR (35'x35' w/50ft curtain range) 669S1M: SIM PIR (601t DlA. 18 curtain ceiling mount) 472452: Embedded SIM Door Contact. 472418: Steel Door adapter for embedded contact. 429CTAD: SIM Smoke Detector / An ESL Model Smoke Detector. 472367: SIM Door Contact! surface-mount white magnetic door contact. 472392: Door Contact Spacer / surface-mount white magnetic door contact spacer. 472417: SIM Door Contact / surface-mount brown manetic door contact. 472423: Door Contact Spacer I surface-mount brown magnetic door contact spacer. 472371S: SIM Overhead Door Contact/ surface-mount waterproof overhead magnetic door contact. 248302: Fuse Holder Kit / For preventing "pulling down" of power from a SIM gateway due to a short circuit. DV1201: FOCUS-VVS Vault and Safe Vibration Sensor I Used in reverberant or non-reverberant vaults. 472372: Power Supply Module: The module comes With terminals for connecting an input transformer, for connecting a battery, for 12VDC power connections, and for connecting a SIM or PID to supervise the application of AC power. SIM TRUNK MODULES 4208U: Universal 8-Point Expansion Module - Provides 8 EOLR supervised points. 4208SNF: Universal Class A Module - Provides 6 Class B supervised points and 2 Class A supervised points. 4209U: Universal Group Zoning Multiplex Module - Provides 4 additional Two-Wire Smoke Detector Loops (Up to 16 Two-Wire smoke detectors for each loop). 4297: Polling Loop Extender Module - Used to extend the polling loop an additional 4000ft (total). Can also be used to extend the SIM Loop. . VIE This document is not intended to be used for installation purposes. We try to keep our product information up to date and accurate. We cannot cover all specific application or anticipate all requirements. All specifications are subject to change without notice. For more information, contact: ADT Security Services Inc. P.O. Box 5035, Boca Raton, FL 33431 Toll Free: 1477-962-5205 "Demand the Best, Prevent the Worst"sm tqco/sftvft M-ij SECTION 22 Equipment 4 ' 4 . C .....- In This Section Basic Systetn Equipment S1J1 Sensors 4 4 43 4 144.4. 944.4.44 4.'• 4,4 '. 44 44 4 44, 4 34 44444 4 Basic System Equipment The ordering information presented below is for basic items such as the control unit, gateways, operating panels, etc., as well as replacement parts. For ordering information for all other system equipment such as, sensors, etc., see the equipment's installation instructions. Where applicable, each item states its current draw in alarm and standby (normal) as follows: ef Al = Alarm current and SI = Standby current. Control Unit (4725111472514) This is the main control and primary power supply for the FOCUS CADET System. Consists of a steel cabinet, finished in beige, with a key-locked front cover that is hinged. Cabinet houses a control board/power supply and has space for two separately ordered 12-volt sealed lead-acid batteries (up to two 17.2AH max.). Control board has facilities for connecting the following separately ordered items: Up to eight 471210 Operating Panels. One 471715 (7187.119) Printer Interface Unit (supervised). One 472490 RF Gateway. Up to four 472270 Access Control Interface Units (ACIU) with card/key readers. The combined total number of operating panels, printers, ACIUs, and gateways must not exceed 31. jr Control unit nominal output voltage on quad trunk is 12VDC. See the Power Requirements section to determine the need for auxiliary power. AI=440mA, Sl300mA 5422-W Assault Sensor Assault Sensor is required if control unit is mounted outside of protected area. Sensor is installed inside of control unit housing and serves same function as a lining. Must be wired to tamper terminals of control unit. 471210 Operating Panel Controls all operations of the FOCUS CADET System; can be used to control all or any combination of the four BA groups. Panel is interactive and features a four-line LCD screen and an alphanumeric keypad. Panel measures 8"w x 4-1/2" H x 1-1/2" D and is normally surface mounted. The keypad can optionally be mounted on a desk, with a 472382 Desk Stand; or angle wall-mounted, using a 148248 Angle Bracket. The unit may be protected from damage using an STI Model 6550 Widebody Keypad Protector. Up to 8 keypads may be used with the FOCUS CADET system. AI65mA, SI32mA 22-1 FOCUS CADET Installation and Setup Guide 472366 Sensor Interface Module (SUM) For interfacing any sensor (that is not already equipped with a SIM) to the SIM Loop. Also used for controlling an output function (via + 12V output). Comes with 6" flying leads for marking connections and a 869706 End-of-Line Resistor (33K ohm, 5%, 1/2W). If SIM cannot be installed in associated device, it must be installed in a separately ordered 370320 (7032) Junction Box. ISI=1mA For information on sensors with built-in SIM, see SIM Sensors later in this section. 477967 Battery, 12-Volt, 7.OAH Sealed Lead-Acid A 12V, 7.OAH rechargeable battery with male tab terminals. Connects to control or power supply via a separately ordered 248222 Battery Wire Lead. Two to four batteries may be connected in parallel to make up a 12V, 14, 21, or 28AH battery. Battery weighs 6.17 pounds (28kg). One 248222 Battery Wire Lead is required to connect each battery. Refer to the installation section of control unit bulletin for instruction in calculating battery standby requirements. 248222 Battery Wire Leads Consists of a set of two wire leads, one red and one black. Used for connection to a FOCUS CADET control board or Remote Power Supply. Two sets of the battery wire leads are needed for installing two batteries in parallel to provide a 12V, 14A11 battery configuration. Each wire lead is 13-1/2" long; wire size is 18 AWG. 471715 Printer Interface Unit Used to interface a FOCUS Type printer into the system. Consists of a printed wiring board that is housed in a separately ordered 472352 Housing Unit. Board has screw terminals for making connections to the RS-485 bus and for connecting 12VAC power, and a header for making connections to a 471958 (7187-058) Printer Kit or a 472369 Secure Printer Kit. A jumper plug serves to connect a user bus-terminating resistor where required. A 443241 Transformer must be ordered separately. A separately ordered 248116 Tamper Kit is available. AI=SI=OniA 472381 Power Unit and Battery Housing A cabinet for housing the components needed to provide additional power for the FOCUS CADET System. Cabinet comes with a key lock and two keys. Power can be introduced directly to the RS-485 Bus (via the red and black wires). Cabinet comes with hardware for mounting internal components, assembly instructions, and basic battery leads. Facilities are provided for housing the following items, all of which must. be ordered separately, as needed: 472372 Power Supply Module (for providing 12VDC power). Module comes with terminals for connecting an input transformer, making battery connections, connecting the 12V output power, and for connecting a SIM to supervise the application of AC power. Power supply output rating is 1.5A if using a 50VA input transformer, and 2.5A if using an 82VA input transformer. One required. 472404 Transformer (72VA), or 443216 or N8167 Transformer (SOyA), or 443218 Transformer (50VA), or 472391 Transformer (82VA), or 443219 Transformer (50VA, hardwire), as required. One required. 477967 Battery (up to 4), as required. One set of 248222 Battery Leads with slip-on terminals are provided. Order another set of leads for each additional battery. 4. 472366 SIM (for supervision of AC power). One required. 866682 Power Unit This power unit comes with a built-in supervisory circuit that monitors the loss of AC and low battery 472404 18V, 72VA Transformer 18VAC/72VA wired-in transformer, which may be required for some commercial fire installation. VISTA-ULAP Attack-Proof Kit Hardware kit required for UL-certified burglary service. 22-2 Section 22- Equipment 472374 Holdup Alarm Switch (W/SIM) A finger-operated holdup device similar to a 441494 (6913-002) Holdup Alarm Switch, except it has a built-in SIM. It is a dual-action latching device that requires user to insert a finger and then pull to activate a holdup alarm. Includes 441495 Reset Tool, which must be used to restore switch to normal condition. Also includes mounting hardware and a 11' (3.4m) captive cable. Communicates with a 472368 SIM loop via two-wire connection. AJ= SI=1mA 472488 Supervised HbrnlStrobe SIM A stand-alone SIM for interfacing various types of horn/strobes (that are not already equipped with a SIM) to the SIM Loop. Current of horn or strobe must be less than 300mA each. Also used for controlling an output function where the +12V output must be supervised. Comes with 6" flying leads for making horn/strobe connections. Horn/Strobe SIM can be installed in the horn backbox or in a separately ordered 370320 (7032) Junction Box. AFSI=3iuA 450S1M PIR (w/SIM') A Sentrol model AP450 Passive Infrared Detector that includes a built-in SIM. It provides 9 curtains of detection of motion in two jumper selectable ranges, 33 ft. and 50 ft. Recommended mounting height is 6 to 10 ft. Communicates with the 472368 SIM Loop via a two-wire connection. Refer to the manufacturer's installation instructions for further details. AI=5mA, S11.78inA 663S1M PIR (wI472366SlM) A Sentrol model AP633 Passive infrared Detector that includes a standalone SIM (472366) housed in the same enclosure. When using this device Option 3 MUST be set to NO. It provides the detection of motion in selectable ranges extending 40 ft.; 80 ft. (wide); and 200 ft. (long range) in 12 selectable patterns. Features Step Focus Curtain technology. Communicates with the 472368 SIM Loop via a two- wire connection. Refer to the manufacturer's installation instructions for further details. AI=25mA, S113mA 669S1M Dual Optic Technology Ceiling Mount PIR (w/SIM) A Sentrol model AP669 Passive Infrared Detector that includes a built-in SIM. The unit provides two independent 1800 fields of view, enabling the detector to cover a single 180° area or two 180° areas (3600). Features 60 ft. diameter 360° coverage, 18 full curtains and can be mounted from a height of 8 to 16 ft. without changing lenses. Communicates with the 472368 SIM Loop via a two-wire connection. Refer to the manufacturer's installation instructions for further details. AI11mA, SI=6mA 429CTAD Smoke Detector (w!SIM) An ESL Model 429CTAD Smoke Detector that includes a built-in SIM. Includes a pulse/alarm LED indicator and a self-test feature that is under program control. Utilizes self-diagnostics that provide complete verification, and CMC annunciation of drifts beyond its sensitivity range. When detector needs servicing, replace optical block cover (ESL Model 211). Communicates with a 472368 SIM Loop via two-wire connection. Refer to manufacturer's instructions for further details. AI=3mA, Sl1mA 472367 Door Contact (w!SIM) An ADEMCO or C&K surface-mount white magnetic door contact with built-in SIM. Unit measures 2- 1/2" Lx 1/2" W x 1/2" H and is furnished with an 11-foot (3.4m) cable. Communicates with a 472368 SIM Loop via two-wire connection. Refer to manufacturer's instructions for further details. A1, SI=1mA 472392 Door Contact Spacer An ADEMCO or C&K surface-mount white magnetic door contact spacer. (2.1/2" L x 1/2" W x 1/8" H). 472371S Overhead Door Contact (w/SIM) An ADEMCO or C&K surface-mount waterproof overhead door magnetic contact with built-in SIM. Unit measures 4-5/16" Lx 1-11/16" W x 3/8" H and is furnished with a 24" armored metal cable. Communicates with a 472368 SIM Loop via two-wire connection. Refer to manufacturer's instructions for further details. Al=, SI=lznA 22-5 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0078:197 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: ADEMCO, 165 Eileen Way, Syosset NY 11791 Contact: David Kalmus (516) 921-6704 Ext 1910 Fax (516) 364-6953 DESIGN: Models 472462, 472462A, 472511 and 472514 * Focus 200 Plus. Focus Cadet combination fire and burglary alarm control unit. Automatic, manual, local, remote station (PPU), central station (PPU), proprietary station (PPU), waterflow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 472462, 472462A, 472511. 472514 Control unit SAFOC200, SAELITE, SAELITEA, Sub-assembly Circuit Board *SAFOC200P SAFOC200PA *SAF()(200.1 *SAF200PA, *SAF200PI COM-UL, 472516, RES-UL Enclosure 443216 or 472404 Transformer RATING: 120 VAC, 18 VAC, Transformer and 12 VOC battery back-up INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings and UL label. APPROVAL: Listed as a combination fire and burglary alarm control units for use with the separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. 'Rev. 05-27-2002 TR This listing is based upon technical data submitted by the applicant. CSFM Fire Engineeilng staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Smoke Detector Placement and Spacing In general ceiling mounted smoke detectors should be located near me center of the room or hall whenever possible, or more than 4 inches (100 mm) from any wall. When the detector is wall mounted, the top of the detector should be 4 to 12 Inches (100-300 mm) from the ceiling (see Diagram 3). Refer to NFPA 72 for further mounting instructions. When more than one detector Is required, spacing of 30 feet (9.1 meters) may be used as a guide on smooth ceilings (as defined in NFPA 72). Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. Diagram 3 - 4 in.-' (100 mm) ceiling 4 in. acceptable here / M 1100 mm) minimum near hire \I 12in. (300 mmi top of detector J maximum acceptable here s,ae wall Where NOT To Place Detectors One of the major causes of nuisance alarms is improper placement of detectors. Avoid locating detectors too close to kitchens or wood stoves. where smoke can be generated. Garages and furnace rooms are poor locations, due to exhaust fumes. Placing detectors too close to bath- rooms can cause problems from steamy baths or showers. Do not install detectors where normal ambient temperature can be over 100°F (37.8C), such as attics. Refer to NFPA 72 for more information. In all cases. detectors should be cleaned once a year, to prevent dust and dirt build- up. See cleaning instructions. Testing the Installation After all connections are complete and the wiring is checked for errors. apply power to the system. There should be no alarm. It an alarm is reported, determine if a detector is in alarm or if there is a problem with the wiring. All smoke detectors shall be tested at least annually in accordance with NFPA 72. Smoke detectors may be tested with UL. Listed canned smoke, a smoldering punk stick or a cotton wick. If UL Listed canned smoke is used, carefully follow manufacturer's directions to prevent damage to the detector. SL 4 /4 *,Mu dflU , iuii Addressable Self-Diagnostic Photoelectric Smoke Detectors (9 I - allation Instructions LISTED 429 0 428 GENERAL DESCRIPTION The ESL 429/428CAD & CTAD low-profile, self-diagnostic, address- able smoke detectors work on the light scattering principle. These models are to be used with the ADT Focus 200 Fire Alarm Control Panel. A pulsed infrared light-emitting diode serves as the light source, and a high-speed photo-diode as the sensing element. This design has superior protection against false alarms caused by dust, insects, RF and ambient-light. Sell-Diagnostics Includes Automatic Sensitivity Testing The 429/428CAD & CTAD continually monitors its own sensitivity and operational status. Upon power-up and once every 24 hours the detector performs a full diagnostic test that includes dynamically testing me sensing chamber and internal electronics. If a detector fails internal diagnostics, the alarm LED will flash once every second, the detector will continue to operate, and the Fire Alarm Control Panel will be sent a trouble signal indicating that the detector needs immediate servicing. If the detector is outside its UL Listed sensitivity range, the alarm LED will flash once every second and the Fire Alarm Control Panel will be sent a diagnostic signal indicating that the detector needs to be cleaned. INSTALLATION The 4291428CA0 & CTAD detectors mount to standard single-gang electrical boxes, four-inch octagonal or four-inch square electrical boxes, or on WIREMOLD No. 5739 fixture boxes. pull wire through the electrical box and connect to the plug-in al block supplied, one wire per terminal (see Diagrams I and 2). Second, dress wiring neatly and snap the terminal block into the back of the detector. Note: The detector cover must be closed comoletely. to su000rl the circuit board. while installing the terminal block. Now, open the cover and mount the detector, using the mounting holes provided (see Diagram 4). All ESL smoke detectors are shipped with a plastic dust cover for use in areas where construction is on-going. Smoke detectors will not operate with the dust cover in place. Remove the dust cover when installation is completed, prior to testing. Diagram 1 ( Plug-in terminal block 429/428CA0 & CTAD Wiring Diagram Diagram 2 First Detector mod / ed: 429/428 7 CTAD / I op L Detector I YLYL Ill. 51. - ++ LISTED O CONTRL J142model 011) 9 Last UNIT BL. YL. Tne detector samples for smoke about every 9 seconds, while flashing :s LED. If smoke is detected, the sampling increases to every 4.5 c.c'nds. Excessive smoke must be detected in three consecutive samples for the alarm to sound. Therefore, when testing the detector .vith smoldering punks or cotton wicks, hold the smoke source near the smoke entry and gently direct smoke into the detector for 20 seconds or alarm is indicated. BE SURE TO PROPERLY EXTINGUISH TH OKE SOURCE AFTER TESTING! This is a go/no-go test and s r.,... . atiable indication of the detectors sensitivity. Control unit alarm and all auxiliary functions should be verified for a complete test of each ietector. The 429/428CTAD samples for heat every 4.5 seconds. Test the heat sensor by using a hot air gun. Aim the hot air gun at the heat sensor from 5-10' away. The detector should go into alarm in less than 30 seconds. Be careful not to melt the plastics. MAINTENANCE, CLEANING and SENSITIVITY TESTING This series of self-diagnostic smoke detectors is designed for easy field service and maintenance. If a detector drifts beyond its approved sensitivity range for more than 24 hours, or fails internal diagnostic tests, :ne unit automatically indicates trouble. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. In accordance with NFPA 72, smoke detector sensitivity should be checked within one .year. after installation and every alternate year thereafter. The replaceable sensing chamber of the 400 series photoelectric jeiector unsnaps for easy field cleaning and service. Whenever the s:atus LED indicates cleaning is necessary, open the detector cover, .Jnsnap and throw away optical block chamber. Then thoroughly blow efl trie optical base and snap a new optical block chamber (part #211) jack in place. NOTE: Be sure new optical block chamber is seated all :ne way down. Close detector cover and verify sensitivity with the sensitivity level test (below). Diagram 5 5w Sensitivity Level Test Mode To activate the sensitivity test mode hold a magnet near the integral reed switch on the hinge side of the detector for more than one second (see Diagram 6). The sensitivity test mode may also be activated from the control panel (see control panel installation manual for details). Diagram 6 To activate sensitivity level test mode, hold magnet on hinge side of detector for more than I second. *v má9 net (for best results -. position magnet slightly off center) The alarm LED provides the following information: Approximate obscuration (%m.) Blinks Indication 429 428 Unserviceable hardware fault is detected 1 2.69 3.05 2 The detector is not sensitive enough __________________________________ 2.46 2.75 3 tyumb tIVi "A. L -477 ?..185'i 1.54 1.50 7 Detector is too sensitive 9 1.31 1.25 8 1.08 0.90 After the sequence of blinks, If the sensitivity is found to be within limits and if all other tests pass, the detector will go into alarm. If the detector is outside its UL listed sensitivity range, the detector will not go into alarm, the alarm LED will flash once every second, and the Fire Alarm Control Panel will be sent a diagnostic signal that the detector needs to be cleaned. If the detector fails internal diagnostics, the alarm LED will flash once every second the detector will continue to operate, and the Fire Alarm Control Panel will be sent a trouble signal indicating that the detector needs immediate servicing. Product Data Sensitivity 429 -minimum ...........................................................2.0 + 0.37%/Ft. - maximum ............................................................ 2.0 - 0.390/./Ft 428 -minimum ...........................................................2.0 + 0.50%/Ft. - maximum ........................................................... 2.0 - 0.500/ofFt. Heat detector specifications ............fixed temp. -135°F, 50 ft. spacing rate of rise- 150F/mm. &> 105°F (8.30C/mm. & > 40.6°C) Operating temperature range ..................32°F to 120°F (0°C to 50°C) Operating humidity range .................................................0 to 95% RH Field wiring size ..................................................................14-24 AWG Color .................................................................white cover/white base Detector size ................................. 6.1"(15.5 cm) D; 1.85' (4.69 cm) H Detector weight...........................................................8.8 oz. (0.25 kg) Packaging ...............................10 detectors are packaged in a carton. Listing .................................................................. 429 - UL, 428- ULC For Instructions on removal of terminal block and circuit board call ecnnucai 5eFVI5 UI OULO1. Diagram 4 - Installation Diagram FLUSH MOUNTING ON 4" OCTAGON BOX 4 square or NOTE: Positive air pressure from wire See Note lest switch WIREMOLD mounting openings, conduit, mounting mounting (No boxes, irregular mounting an 595 surfaces, or plenums causing air movement through and away Alit 1 6.1 (15.5 cm) Shp gam 4' octagon from the detector may prevent mounting proper operation. Seal all '470Crn1 55 = openings causing unwanted air flow using UL Listed expanding ret foam or Duxseal. alarm ed Statue LEO SENTROL Sentrol reserves the ngfll 12345 SW Leveton Dr., Tualatin, OR 97062 to change specifications without notice. Tel.: 503.692.4052 Fax: 503.691.7566 E S L http//www.sentrol.com U.S. & Canada: 800.547.2556 01999 Sentrol Technical Service: 800.648.7424 A r R C) C) L C 0 F SE N T p.o i. FaxBack: 1.800.483.2495 12839B- 1009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0447:128 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: ESI/Sentrol Inc., 12345 SW Leveton Dr., Tualatin, OR 97062 Contact: Gene Hukkanen (503) 691-7369 FAX (503) 691-7575 DESIGN: Model 429-AT, -C. -CAD, -CT, -CTAD, -CRT, -CST or -CSST; and Model 449-AT, -C, - CT, -CRT, -CSRH, -CSRT, -CS(S)T, -CSSTE, -CSTE, -CTE, -CLT or -CSLT photoelectric type smoke detectors. Units may employ an integral heat sensor (135° F fixed temperature and 15° F per minimum rate of rise) and sounding device. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electricaVtemperature rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed electrically compatible fire alarm control units except *Models 429CAD and 429CTAD are intended for use only with ADT Model Focus 200 (CSFM Listing No. 7165-0085:171). NOTE: Integral heat sensor and sounder are supplemental to smoke detector. 'Rev. 07-17-96 .0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 21, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K.. AREND, Senior Deputy Program Manager \)] . ADT-BG12L Manual Fire Alarm Pull Station Section: Conventional Initiating Devices DA.487T8 • F-050 October 24. 2000 GENERAL The ADT-BG-12L Is a cost-effective, feature-packed, non-coded, dual-action manual fire alarm pull station. It was designed to most multiple applications with the Installer and end-user In mind. The ADT-BG-12L provides ADT Fire Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating Input signal. Its Innovative design, du- rable construction, and multiple mounting options make the ADT-BG-12L simple to Install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (dual-action), yet designed to prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down position to dearly indicate the station has been operated. The word "ACTIVATEDO appears on the top of the handle in bright yellow, further Indicating operation of the station. Operation handle features white arrows showing basic op- eration direction, for non-English-speaking persons. Braille text Included in finger-hold area of operation handle and across top of handle. Key-lock model available. Station can be opened for Inspection and maintenance with- out initiating an alarm. Product ID label viewable by simply opening the cover, label is made of a durable tong-life material. The words ONORMAV and *ACTIVATED0 are molded into the plastic adjacent to the alarm switch (located inside). - Four-position terminal strip molded Into backplate. - Terminal strip includes Phillips combination-head captive 8/ 32 screws for easy connection to Initiating Device Circuit (IDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWGI3.25 mm. Terminal numbers are molded Into the backplate, eliminating the need for labels. Switch contacts are normally open. Can be surface (with SB-b) or semi-flush mounted. Semi- flush mount to a standard single-gang, double-gang, or 4 (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by up to 1/2* (12.7 mm). PATENTED, U.S. PATENT NO. D428,351 OTHER U.S. PATENTS PENDING Sta Fire California (2)Marshal 7150 te -0085:194 Approved LISTED $285 I I Optional trim ring (BG-TR). Designed to replace the popular ADT-BG-10 Series. Packaged in attractive, dear plastic (PVC), clamshell-style. Point-of-Purchase packages. Packaging indudes a cutaway, dust/paint cover In shape of pull station. CONSTRUCTION Cover, backplate and operation handle are all molded of du- rable poiycarbonate material. Cover features white lettering and trim. Red color matches System Sensot's popular SpectrAW01 horn/strobe series. This document is not Intended to be us.d.for Installation purposes. We try to keep our product kifoimsdon up4oda1. and accurate. We cannot cover .0 specific applications or anticipated requirements. All specifications an subject to dwl. dihout notice. I For more information, I On. Town Canter Road. Boo. Raton. FL. 33431 \)J I Security Services, Inc. Phone: (561) 988-3600 FAX: (561)988-3875 I OPERATION The ADT-BG-1 2L manual pull station provides a textured fin- ger-hold area that Includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows Indicating how to oper- ate the station, provided for non-English-speaking persons. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched In the down posi- tion, the word "ACTIVATEDO appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible Rag. Resetting the station Is simple: insert the key, twist one quarter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to Its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: BG-12 SB-b Height: 5.500 inches (13.97 cm) 5.500 Inches (13.97 cm) Width: 4.121 inches 4.125 inches (10.4673 cm) (10.4775 cm) [Depth: 1.390 Inches 1.375 inches (3.5306 cm) (3.4925 cm) Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A © 30 VAC orVDC. PRODUCT LINE INFORMATION Model Description ADT-B042L Dual-action pull station with SPST N/O switch, screw terminal connections, key lock. SS-10 Surface backbox. BG-TR Optional trim ring. 1.390 (35.306) Wire Length Strip Gauge 7 1.000 (25.40) —L ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually de- tected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations In white letters, 1.00 inches (25.4 mm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-b; or semi-flush mounting on a standard single-gang, double-gang, or 4' (10.16 cm) square electrical box, and shall be installed within the lim- its defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. 0.750N (19.05) 5.500 (139.70) Page 2*12 - OA-46778 • 10124100 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1574:178 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: ADT Security Services, Inc., 695 Route 46 West, Suite 200, Fairfield, NJ, 07004-1561 Contact Ron Dalton (310) 725-2972 FAX (310)725-2942 DESIGN: Models ADT-BG-12, ADT-BG-12L, ADT-BG-121X and ADT-NBG-I2LX fire alarm pull boxes. The series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Ustee's name, model number and UL label APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible lire alarm control units. For indoor use only. NOTE: Formerly 7150-0085:194 XLF: 7150-0028:199 05-20-2004 2j~ This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to Iiste&s data sheet installation instructions and/or other suitable information sources. Date Issued: JUNE 23, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Models Available Red White S1224MC S1224MCW S1224MCP S1224MCPW S 1224M C S1224MCSP Red White P1224MC P1224MCW P1224MCP P1224MCPW P1224MCK P1224MCSP Homsi Red White H12/24 H12/24W H 12/24K Product Overview ):crttr or.t:the? 2V or 24V tvtt' ettasae uu3ad KWi:'s. ttnu o ,ue ooui ecio red- rea that.ntut the what rng of frela e,pknti ts ilrsbk and "he catiahiltt' ' % (ct'f - i' cares. t . o-3 tu -ust or r 24 ot etaten. With no cvea!; iSV: S ot .'10 candela roc'ogn-n ;3114 se that Combines o€j5ormcrn e. 'tøt esse flexibility.and os .4t!: . t5,Yh, J) .:.1()tr.th:la ts{ peg race, the ScvtrA t Setetitis Ottt .ttoide t)Mh t3 i v'.ti($ti ktnc syiou wtts the S t4test nnns. 4/I strobe and horn/strobe models incorporate a new patent-pending voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device. .owet cttent thaw :.sy Valp sfct .;tk f(;? ctn I? tir.tiag with Qc<Click Synd3ztL' wiU; MDI Syoc oi.iirit: nehe MC U.,i97 I'd ADA btcO LISTED c;s549v602uM964 csrgvzo,ii 1751 X $5512 14011 approved 12202t '14' id02'i3 5)16150 12602) Perortr.nce. SpectrAlert selectable output wall-mcunt horns, strobes, and horn/strobe offer key performance features long associated with the SpecnAlert name. The select- able candela strobes and horn/stiobes offer average current draws tha are not only lower than conventional fixed-candela SpectrAlert products, but also lower than similar selectable candela products. B) consuming less current, the ability to connect even more devices per loop is possible, remting in a lower installed cost. ltoo. SpectrAlert selectable output horns, strbes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operatioa; the ability to use standard size hackhoxes with no encroachment into the box; and universal mounting. incorporating the labor-saving Q uickClick' feature. Such labor-savings features make wire connections simple and fast. further reducing installed cost. FI11t. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24", with no setting required; the devicel recognizes and self-adjuts to the correct current automatically. 1errporal 3 or Continuous tone options Continue to be available, in either an Elecornechan.cal or 3kHz pattern. AesUeths. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a con- sistent and aesthetically pleasing appearance across the entire product line. Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4' x 4' x 11/2" back box or a single gang 2' x 4' x 1/s' back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert prod- ucts, when used in conjunction with the accessory Sync•Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall con- sist of a xenon flash tube and associated lens/reflector system. Hon/Strobe Cblnatfon Horn/Strobe shall be a System Sensor SpectrAlert Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/ strobe models shall operate on a coded or non-coded power sup- ply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor Sync.Circuit _____listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/ strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/1' x 411/16 x 21/Il back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Specifications Wnw 1è5t SpectrAlert horn/strobe and horn only work on "walk tests' with time dura- tions of 4 seconds or greater Input Terrr!:as 1.2 to 18 AWG Strobe and horn/strobe with universal plate 5' x 5/" x 215/16 Strobe and horn/strobe with small footprint plate 3/8' x 5/8° x 2/i' Horn with universal mounting plate 5' x 5/8' x 1/it' Horn without mounting plate 2I5/1 x 5/i? X 1/16' W:gnt, !iorn on'y 7.2 oz. Weight, strobe and honVstrc.be 8.8 oz. Mounting 4' x 4' X 11/2' or 2' x 4' x 1/' standard boxes indoor Operating Temperature 32°F to 120°F (0°C to 49°C) Maximum hum:dity 95% as tested per UL464 Qterai irig Tempostue Weatherproof (horn and horn/strobes) 32°F to 150°F (0°C to 66°C) (outdoor strobe only) -40°F to 158°F (-40°C to 70°C) ULC Canadian Models -40°C to 66°C Voligec 12 or 24VDC and FWR unfiltered 0c.nrathg voltage runge 12V: 8-17.5V; 24V: 16-33V 0peuitig voltage range* (with 5y!1c.Circui !rio.:ul, MI).) 12V: 947.5V; 24V: 17-33V *Note for Strobes: Do not exceed: 1) 16-33 or 8-17.5 voltage range limit; 2) maximum number of 70 strobe lights when connecting the MDI. Sync module with a maximum line impedance of 4 ohms per loop and; 3) maximum line impedance as required by the lire alarm control manufacturer U.S. Fn'er.t. Numbers 5,593,569 5,914,665 6,049,4.46 SpectrAlert Current Draw cO \5pA•Gb-1fV\Nb SeAes Candela FWR Operating Cuneat-Stiebe (rA WMS) / flc(operatlng Curreni Strobe rnA RMS) FWR eatin Cunent-Ihin (mA RMS)'\ OC Operathtg Currant-Hon (mA ElMS) Hon Aucretifty zs' 12V zv 12V 24v\ 12V 24V S1224MC Strobes 15 112 I 4 127 59 11111 III 11111 IJIII!flI 90 ' I !IIIIIIIIIIIIII IllIllIllIllIllIl III! I 1111111 15/75 30 1. 135 I ," 74 /93 127 69 75 158 ' 160 1, , , 110 208 , 209 P1224MC om ro S 15 112 64 127 59 45.7 57.5 44.4 57 75 1.5/75 135 74 127 69 45.7 57.5 44.4 57 75 30 93 90 575 57 75 75 158 11111(111 ii I 160 III liii 575 iiiiiIi I III 57 75 110 208 209 575 57 75 H12/24 Horns III liii I 45.7 57.5 44.4 57 75 SpectrAlert Mounting and Operation Candela Selections Selectthle Horn Tones For strobe candela selection, adjust slide switch located on the Tmspw&f Low Volume rear of the product while watching the viewing window on the I side of the reflector. I I High Volume Moo.Tetnperal I Low Volume High Volume DIP Switch Operation Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Electromechanical 3000 Hz Interrupted Fadoty OFF ON Defauk 1DPSwtch Low Towel ?krt.Temporal J Eledromedi. I 300" Base (rear) LJ PI1QO Ceadate Gpeitieg Vatkge i2V 24V 15 OK OK 15/75 OK OK 30 OK 75 OK 110 OK Viewing V Typical weatherproof mounting with universal plate ,—Plate ,—#8-36x 1& Flat Head V Screw (4 total) A0120OO Entrance \ —sici \—Paper Liner For Plate Gasket SpectrAlert Ordering Information Model DescrIption P1224MC Selectable Output Horn/Strobe, 12/24 volt, red PI224MCW Selectable Output Horn/Strobe, 12/24 volt, white PI224MCP Selectable Output Horn/Strobe, 12/24 volt, red, plain housing PI224MCPW Selectable Output Horn/Strobe, 12/24 volt, white, plain housing P1224MCK Selectable Output Horn/Strobe, 12/24 volt, red, weatherproof PI224MCSP Selectable Output Horn/Strobe, 12/24 volt, red, FIJEGO housing S1224MC Selectable Output Strobe, 12/24 volt, red S1224MCW Selectable Output Strobe, 12/24 volt, white S1224MCP Selectable Output Strobe, 12/24 volt, red, plain housing S1224MCPW Selectable Output Strobe, 12/24 volt, white, plain housing S1224MCK Selectable Output Strobe, 12/24 volt, red, weatherproof SI224MCSP Selectable Output Strobe, 12/24 volt, red, 'FUEGO housing Notes Model DescrIptIon 1-112/24 Horn, 12/24 volt, red H12/24W Horn, 12/24 volt, white H12/24K Horn, 12/24 volt, red, weatherproof Ac:essor'ts MDL Sync.Circuit Module, red MDLW Sync.Circuft Module, white MDLA Sync.Circuit Module, red, Canadian model MDLWA Sync.Circuit Module, white, Canadian model SMP Small Footprint Mounting Plate, red, for single- gang back box S-MPW Small Footprint Mounting Plate, white, for single. gang back box BBS Surface Mount Back Box Skirt, red BBSW Surface Mount Beck Box Skirt, white D-MP Universal Mounting Plate (replacement), red D-MPW Universal Mounting Plate (replacement), white WBB Weatherproof Back Box Agency Listings - Indoor models: UL, ULC, FM, CSFM, MEA. Weatherproof modehe UL, CSFM (strobe only), MEA, ULC. All of these SpcctrMezt products are designed for wall mount only. All weatherproof models swat use weatherproof back box modelWBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of lees than 75 candela strobes. AU 15175 candela strobes or horn/ strobes are recommended for 20' x 20' rooms or less. System Sensor Sales and Service System Ssnscc Headquarters System S.nsos Cmisda System Suns., In ChIna System Season - Fe, East System Sense, - IndIa 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles. IL 60174 Fx: 905.812.0771 Fx: 86.29.524.6259 Fx: 85.22.736.6580 Fa: 91.124.237.3118 Ph: 800/SENSOR2 System Sessor Eutop. System Sense, In Slage,. System Sensor -Austaft System Sans., - Itassla Fx: 630/3774495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 Documents.on-Demand Fa: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Fa: 70.95.937.7983 800/736-7672 x3 www.systemsensor.com 02004 Systan Snisun. The company isserve, the ,tht to change product specAc8tiom without notice. A050325603.5/04.41200 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE ARE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1209:223 Page 1 of I CATEGORY: Audible Devices LISTEE: System Sensor, 3825 Ohio Ave, St Charles IL 60174 Contact Trish Linhart (630) 377-6674 FAX (630) 377-7245 DESIGN: Models P1224MC, PI224MCW, PI224MCSP, PI224MCSPW, *PI224MCP PI224MCK, and PI224MCWK combination horn/strobes with selectable candela. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 8-33 VDC/FWR 12124 VDC/FWR Selectable :l5cd, 15/75cd 24 VDC/FWR Selectable : 30cd, 75cd, hOod INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. These sounder/strobe combination units are not intended for flèkl assembly. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as horn strobes for use with separately listed compatible fire alarm control units. Suitable for the hearing impaired application. For wall mount and indoor use only. Models with suffix suitable for extended indoor operation temperatures 32t0150° F(010 66 °C) and have NEMA type 3R enclosure rating for outdoor use. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. 'Rev. 02-24-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to varify consct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager SLPO.IIT. 16.0 7,1 %VMGW rims" GVAX 0 D 16.0 La OT 4fl4SO 7SC 1000 2 IS SG __ lwcI cw 1 $.O ACTS3O 500 16$ ZC IS G ow 1WIIPI.M 0*J uo.t out. 16.0 CT 34 rc icoo luww =up" 1mG __ flP(ILM om saJ SO 0T 3l63 500 in IS lfr(IP1M cw SV 1 flG 1 12 luaw=l .0 AN, SECTION2 FIRE ALARM CABLE I I -_ IcosoucToQi I I I Fa"O'"'m I MT I OLT I wcs I I I I I 1 I I 2.20 OONT sa ii-' CALL. I 6tI-423-C94 7 ORDERS- PiioeiC 1.38.43.0947. FX 847.797.3853 m-i 2.21 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS USTING PROGRAM LISTING SERVICE USTING No. 7161-1487:100 Pagel on CATEGORY: USTEE: DESIGN: Cables-Fire Protective Signaling Genesis Cable System, 7701 95th Street, Pleasant Prairie, WI 53158-2716 Contact: Orville Allen '(262) 947-0720 Fax (262) 947.0724 Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP. HDPE or LDPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp.. Grade GA-91-84, GPT-45. GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed Installation instructions, applicable codes & ordinances, NEC Article 760. and In a manner acceptable to the authority having Jurisdiction. MARKING: Ustee's name, Type FPV and UL label. APPROVAL Listed as power-limited fire protective signaling cables. Rsv. 06.18.2003 This NOV Is based upon technical data submitted by the appicent. CSFM Fire Bneedag staff has reviewed to test results and/or other data but does not make an Independent veelflcaUon of any dons. This listing Is not an endorsement o r recommendation of the Item listed, This listing Should not be used to vedlr correct operational requirements or Inslellation atterta. Refer to llste&s dale sheet, Installation Inabuclions andlor other suitable lnfcnnallon soitcss. Date Issued: JUNE 23, 2004 IJstThg Expkes June 30, 2005 AUThOIIZed By DIANE K. AREND, Senior Deputy Program Manager