HomeMy WebLinkAbout6200 AVENIDA ENCINAS; ; FA080032City of Carlsbad Fire Alarm Permit Permit No: FA080032 6200 AVENIDA Job Address: Status: ISSUED ENCINAS Permit Type: FALARM Applied. 5/22/2008 Parcel No: Approved: 5/22/2008 Lot #: 0 Reference No.: Issued: 5/22/2008 PC #: Inspector: Project Title: ENCINA WASTEWATER TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: Owner: SIMPLEX GRINNELL 3568 RUFFIN ROAD SAN DIEGO CA 858-633-9100 Fees ($) . Add'I Fees ($) . Total ($) Balance ($) 130 0 130 0 tqcci / Fire & I Security / SimplexGrinnell SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com PRODUCT SUBMITTAL 16721 FIRE ALARM PROJECT: ENCINA WATER POLLUTION CONTROL FACILITY 6200 AVEN IDA ENCINAS CARLSBAD, CA 92009 REVISED FACP TO 4010 Cal APPROAVAS SUBMITTED bfAwvL CARLSAD9RE DEPARTMENT 12/9/2008 REV.#: 1 PROJECT #: 480- REV 1 Sb FAO~0092- tqco / Fire & I Security I Simplex6rinnell SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 TWO: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com TAB# SYSTEM I FIRE ALARM 2 APPENDIX 12/9/2008 REV.#: 1 PROJECT #: 480- tqcci /Fire & / SimplexGriAnell Security SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE ALARM SYSTEM ITEM MODEL NO. DESCRIPTION A 4010-9101 4010 FIRE ALARM CONTROL PANEL B 2081-9272 BATTERY 6.2AH C 4090-9001 SUPERVISED lAM C.S.F.M. NO. 7170-0026:226 N/A 7300-0026:223 12/9/2008 REV.#: 1 PROJECT #: 480- .Simplex TrueAlarm® Fire Alarm Controls UL, ULC Listed; FM, CSFM, Model 4010 Fire Alarm Control Panel for TrueAlarm and MEA (NYC) Approved* Analog Sensors and lDNetTM Addressable Devices I1ui* Standard features include: Up to 250 addressable TrueAlarm sensor or addressable device points using IDNet communications that operate with either shielded or unshielded twisted pair wiring** Four, 2 A notification appliance circuits (NACs) with solid state current protection Internal event reporting DACT module (standard on models 4010-9101, 4010-9102, & 4010-9150) UL listed to Standard 864 Installation convenience features: Power-limited design with electronic modules contained on one-piece chassis Up-front terminal blocks for wiring access Compact NEMA 1 rated cabinet is available in beige or red and can be pre-shipped for early installation Setup, programming, and maintenance features: Device level ground fault search, locate and isolate Auto Program for general alarm operation TrueAlarm, individual analog sensing with front panel information and selection access "Dirty" TrueAlarm sensor maintenance alerts, service and status reports including "almost dirty" Default TrueAlarm sensor device type operation Duplicate address error detection Front panel or PC programming TrueAlarm sensor peak value performance report WALKTESTM silent or audible system test' Software verification simulation mode Supports the following IDNet devices: Addressable manual stations Quad-state zone adapter modules (ZAMs) for initiating device monitoring IDNet ground fault/short circuit isolator base for TrueAlarm sensors Quad-state line powered individual addressable modules (lAMs) for initiating device monitoring and relay control Available option modules include: Door mounted 24 LED annunciator (std. on ULC models) Network, or Point Reporting DACT Class A NAC adapter module RS-232 ports for printer and maintenance PC Additional power supply; Auxiliary Relay Module or City Interface Equipment for Suppression Release Applications (refer to data sheet S4010-0003) Compatible with Simplex® auxiliary panels: lrueAlert® Addressable Controllers and NAC power extenders (IDNet controlled and conventional) 4003 Voice Control Panel 4081 Battery Cabinet with charger for 50 Ah batteries 4010 Fire Alarm control Panel (with standard door) DPsrintic TrueAlarm fire alarm control panels have the ability to provide location accuracy for monitoring and control. When equipped with TrueAlarm analog sensing for smoke and heat detection, the processing power of the control panel also has the ability to analyze conditions at each location to provide accurate detection with significantly reduced maintenance costs. The 4010 TrueAlarm Fire Alarm Control Panel has been specifically designed to provide addressable operation and analog detection in a cost-effective package for application sizes that previously were considered only appropriate for conventional zoned monitoring. Installation and Service Ease. The 4010 mounts on a single chassis for quick installation and removal. Terminal blocks are large and up-front for easy access and inspection. Optional modules are easily and quickly installed and programmed as required. The 4010 cabinet provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting. Smooth cabinet surfaces are provided for locally cutting conduit entrance holes exactly where required. 4010 cabinets and electronics can be ordered separately, allowing early cabinet installation. Ground Fault Assistance. Ground fault problems often occur during installation. The 4010 provides isolating circuitry and software-controlled sequencing to isolate ground faults to specific identified locations. This assistance helps the installer to accurately locate the wiring problem for quicker repair. Refer to page 6 for listing details. This product has been approved by the California State Fire Marshal (CSFM) puissant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 71700026:226 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. TrueAlarm analog smoke detection and IDNet addressable devices are protected by one or more of the following U.S. Patents: 5,155,468; 5,173683; 5,543,777; 5,400014; 5,552,765; 5,552,763; DES. 377,460. t WALKTEST system test is protected under U.S. patent #4,725,818. S4010-0001-9 10/2004 [IMhI•1I]rli1I1!lii1iit11vj Extensive Feature List. The 4010 Fire Alarm Control Panel provides access to an extensive feature list that includes: Providing easy and powerful operator information with a logical, menu-driven display Extensive and automatic diagnostics for maintenance reduction History Logs available from the LCD or capable of (optionally) being printed Software Verification, allowing detailed logic programming simulation to be conducted without activating connected outputs Control Panel (or service PC) label editing Password access control Auto Program Quick Configuration (Quick-CFIG) of connected modules and IDNet devices for general alarm operation to quickly get the system up and running rDMiI.1fl'JTh! rmT I Convenient Status Information. With the locking door closed, a window allows viewing of the status display. The 4010 status panel provides a two line by 40 character, super-twist LCD information display and eight status LED indicators as shown in the illustration below. From this display, the LED indicators will describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door will provide access to the control switches and allow further inquiry by scrolling the display for additional detail. (Refer to control panel functional illustration below.) WALKTEST Diagnostic Operation Mode. The patented WALKTEST process allows a single person to perform system test. The system records test inputs such as intentional alarms or trouble and either logs the response (silent WALKTEST operation) or outputs a brief, recognizable audible notification signal (audible WALKTEST operation). Extended Operator Control Panel Functions FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, remain on until reset 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 40 characters for custom label information FIRST ALARM DISPLAY: Operation can be selected for maintained display of first alarm until acknowledaed THREE PROGRAMMABLE LEDs provide custom labeling (labels insert into a pocket), the top two LEDs are selectable as red or yellow, the bottom LED is selectable as green or yellow ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge and silences the operator panel and all annunciator tone-alerts SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts Non 18—Oct SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal N I NINE EXTENDED FUNCTION KEYS (accessible with \ door open) select and scroll through display prompts for \ locating additional system information, performing \ maintenance functions, or for front panel programming ALARM SILENCE causes audible notification appliances to be silenced, used after evacuation is complete and while alarm source is being investigated I SYSTEM I 12:02: 15gm CONTROL I PANEL VIEW with j2oorded: I- TROUBLE ACK acknowledges system troubles, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts S4010-0001-9 10/2004 Overview. The 4010 provides IDNet addressable device communications. Using a two wire circuit, individual devices such as manual fire alarm stations, TrueAlarm sensors, and sprinkler waterfiow switches can be directly connected (or interfaced) to the IDNet controller to communicate their identity and status. This addressability, allows the location and condition of the connected device to be displayed on the 4010 panel LCD and on system annunciators. Additionally, control circuits (fans, dampers, etc.) may be individually controlled by using a relay 1AM (individual addressable module). The 4009 IDNet NAC Extender or the lrueAlert Addressable controller can be controlled for local or remote notification appliance expansion. (Refer to individual device documentation for further details.) Capacity. A total of 250 addressable monitor and control points may be intermixed on the same pair of wires. By using Zone Adaptor Modules (ZAMs) or Individual Addressable Modules (lAMs), conventional initiating devices can be connected to the IDNet circuit. IDNet Addressable Operation. The IDNet controller continuously interrogates each addressable device on the communication channel for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Sophisticated poll and response communication techniques ensure supervision integrity and allow for "T-tapping" of the circuit for Class B (Style 4) operation. Wiring Requirements. Refer to the specifications chart below. Distances are for shielded or unshielded wire. Shielded wire may provide protection from unexpected sources of interference and may be required for some applications. Wiring Specifications Size 18 AWG minimum Wire Preferred Shielded twisted pair (SIP) Unshielded twisted pair (UTP) Acceptable Farthest Distance from Control Up to 2500 feet (762 m) Panel to Device Total Wire Length Allowed With T Taps for Class B Wiring Up to 10,000 ft (3 km). immommmm TrueAlarm System Operation. IDNet communications are used for TrueAlarm smoke and temperature sensors. Every four seconds, smoke sensors transmit an output value based on their smoke chamber condition. The 4010 CPU maintains a current value, peak value, and an average value of each sensor's output. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Programmable Sensitivity. The sensitivity of each sensor can be field programmed at the 4010 Control Panel for different levels of smoke obscuration (in percent) or for specific heat detection levels. In order to evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read and compared to the alarm threshold directly in percent. S4010-0001-9 10/2004 TrueAlarm heat sensors can be selected for rate-of-rise detection as either 15° F (8.3° C) or 20° F (11.10 C) per minute with an independent fixed limit of 135° F (57° C) or 155° F (68° Q. TrueAlarrn heat sensors can also be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 1550 F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. To additional IDNet devices, up to 250 total TrueAlert Addressable Controller Supervised IAM Modular TrueAlann sensor With IDNet isolator base Quick-Connect TrueAlarm sensor 4010 Fire Alarm Control Panel with annunciator door 4010 Control Panel with Typical IDNet Devices 17Y1 TrueAlarm operation gives the 4010 system the ability to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 (National Fire Alarm Code) requirement for a test of the sensitivity range of the sensors is fulfilled by the TrueAlarm ability to maintain the sensitivity level of each sensor. Modular TrueAlarm sensors use the same base and different sensor types (photoelectric smoke sensor, or heat sensor) can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. Printer (Simplex model 4190-9013) True Alarm sensor data can be displayed on the system LCD, on a remote maintenance PC, or printed on a remote printer. With the proper operator access, a TrueAlarm Service Report can be generated to list the specific details of each TrueAlarm device. This report, as well as the Status Report can either be displayed on the remote maintenance PC or captured permanently by using a remote 80 character printer. The report samples below illustrate the format provided on either the remote maintenance PC or a printer. This information is available at the system LCD by identifying the specific point of interest and reading one point at a time. Model 4190-9013 is a UL Standard 864 listed 80 column, 24 pin dot matrix printer (refer to data sheet S4190-0011). (Model 2190-9039, a 24 VDC, 40 column printer, is compatible with the 4010 for event printing only. Refer to data sheet S2190-0014.) Local maintenance BEIM computer :. -- 4010 Fire Alarm " One connection type per 4010, Control Panel \ selected by module choice; max. '-..' wiring distance is 300 ft (91 m) @9600 baud Remote authorized maintenance computer connected via dial-up Service Modem Connection RS-232 Connection Options (refer to module selection on page 6) TrueAlarm Status and Service Report Samples 1 0- Simplex 4010 Fire Alarm System Page 1 REPORT 3 : TrueAlarm Status Report 2:43:03 pm Mon 18-Oct-04 Zone Sensi- Almost Name Custom Label tivity Device Status Dirty M1-1 ANALOG PHOTO CLEAN ROOM 0.5 % NORMAL M1-2 ANALOG ION CLEAN ROOM 1.3 % NORMAL M1-3 ANALOG PHOTO MAIN LOBBY 2.5 % NORMAL *YES* M1-4 ANALOG PHOTO CONFERENCE ROOM 1 2.5 % NORMAL Ml-10 HEAT DETECTOR GARAGE 135 F NORMAL Mi-11 ANALOG PHOTO KITCHEN 3.7 % NORMAL *YES* END OF REPORT Typical TrueAlarm Status Report Information Printout and/or Maintenance PC Screen Simplex 4010 Fire Alarm System Page 1 REPORT 4 : TrueAlarm Service Report 2:56:09 pm Mon 18-Oct-04 Dev Alarm Avg Current! Peak! State Num Custom Label at: val % alarm % alarm 1 ANALOG PHOTO - CLEAN ROOM 0.5! 83 67 68! 1% 72! 10% NOR 2 ANALOG ION - CLEAN ROOM 1.3!209 94 97! 2% 101! 1% NOR 3 ANALOG PHOTO - MAIN LOBBY 2.5!185 117 117! 0% 125! 42% NOR 4 ANALOG PHOTO - CONFERENCE ROOM 1 2.5!161 93 93! 0% 93! 0% NOR 10 HEAT DETECTOR - GARAGE 135F!253 --- 63!-67F 66! 69F NOR 11 ANALOG PHOTO - KITCHEN 3.7!216 116 116! 1% 110! 36% NOR END OF REPORT Typical TrueAlarm Service Report Information Printout and/or Maintenance PC Screen 4 S4010-0001-9 10/2004 MflTflVi ITI1tuit*i N2 Communications for Serial Annunciator Control. Control for up to 6 remote Simplex Annunciator products including 24 Point 1/0 Module, and LCD Annunciator. Includes extensive troubleshooting diagnostics. Access Port. RS-232 service port for connecting PC tools for service diagnostics and for programming the CPU Flash EPROM memory. IDNet Addressable Communications Channel. Addressable channel provides communications for up to 250 remote addressable devices, including TrueAlarm analog sensors and isolator bases (see descriptions on page 3). Four NACs. Class B output is standard, rated for 2 A @ 24 VDC nominal, with solid state current protection. Class A operation is optional with the addition of an adapter module. NAC operation can be selected for "on-until-Silence" or "on-until-Reset," and can be Temporal pattern, 20 or 120 bpm March Time pattern, or continuous. Each NAC is also individually selectable to control Simplex synchronized visible notification appliances and to control audible notification appliances using SmartSyncTM control, allowing separate audible and visible appliance operation using a common 2-wire circuit. (Class A, Style Z, SmartSync circuits require SmartSync Control Module 4905-9938, refer to data sheet S4903-0010 for details.) Two Auxiliary Output Circuits. Operation is programmable for trouble, alarm, supervisory, or other fire response functions. Output is one Form "C" dry contact each, rated 2 A @ 24 VDC. An optional relay kit is available for switching up to 1/2 A at 120 VAC. Power Supply. Standard output is 4 A @ 28 VDC, filtered, non-regulated. Internal system power is provided separately, allowing the 4 A to be available for NAC and auxiliary power tap functions. Over-current protection is solid state and self-resetting. Auxiliary Power Tap. Provides up to 1/2 A of the standard power supply voltage, over-current protected. Battery Charger. Capable of charging up to 25 Ali sealed lead-acid batteries (40 10 cabinet mounted). A recharge time of 24 hours is typical with stable 120 VAC input. For applications requiring larger batteries, external charger/cabinet assemblies are available. A depleted battery cutout feature is programmable to advise and/or to reduce current when battery voltage is low. (The 4010 is available with a Simplex Network Interface. 4010 points can be declared "public.") Network Interface, Fixed Media. Available for wired applications. Network Interface, Modular Media. Available for wired connections or fiber optic. Require separate media modules. May be both wired, both fiber optic, or one of each. DACT, Point Reporting Module. Provides serial output information that can send location details to a remote receiving station. DACT, Event Reporting Module. For applications where simple event status information is required (Alarm, Trouble, Supervisory, and AC power failure). Dual RS-232 Module. Available for interfacing to a printer and a maintenance PC. Single RS-232 Module with Service Modem Connection. Provides one port dedicated for connection to a printer, and a second port dedicated for dial-in from a service computer, typically located off-site. With an off-site computer, programming changes and system diagnostics can be performed remotely, reducing service time for repair or reprogram. Security is maintained by password protection. 19TITtre am. Standard 4 A Expansion Module provides two taps of 2 A each, 28 VDC, filtered, non-regulated, similar to the standard power supply capacity. Suppression Release Power Supply provides two taps of 2 A each, regulated at 24 VDC ± 10%. May also be used for other applications requiring regulated voltage. Use for suppression release requires a front panel mounted release appliqué that is provided with this power supply and also may be ordered separately. Battery Meter Module provides panel mounted ammeter and voltmeter for power supply monitoring. Dual Circuit Class A NAC Adapter Module mounts on the main 4010 printed circuit assembly and provides the additional circuitry needed for Class A operation. Dual Circuit City Connect Module provides the interface required for direct wired reporting to conventional city connection circuits. (Available with or without disconnect switches.) Expansion Power Distribution Module provides two additional termination points for the 1/2 A auxiliary power output, or for one tap of the expansion power supply. Relay Option Module. Provides three relays, one each for Alarm, Supervisory, and Trouble. Relay contacts are selectable for normally open or normally closed and are rated 2 A @ 32 VDC maximum. Up to six of the following modules may be connected to the Simplex N2 serial communications bus. 4606-9101 LCD Annunciators provide remote acknowledge, reset, and alphanumeric status display. (Refer to data sheet S4606-0001.) 24 LED Annunciator Doors are standard on ULC listed models and are available as door-only assemblies for electronics only packages or other aftennarket applications. This option uses the 24 Point I/O module with all points pre-assembled as LED outputs, with individual labels and each LED is selectable as red or yellow. 4605 Series 24 Point 110 Modules are available for remote mounting and provide 24 points that can be programmed as either general purpose switch inputs or system controlled outputs. Typical applications are for remote annunciators and monitoring and control of other related processes. (Refer to data sheet S4010-0002.) S4010-0001-9 10/2004 Category "I Control Panel Assembly (select one) Model 4010-9101 Description UL Listed 4010 Fire Alarm Control Panel with: door, cabinet, power supply/battery charger, IDNet interface, 4 NAGs, 2 auxiliary relays, and external N2 communications interface; 4010-9101 and 4010-9102 include internal common event reporting DACT Voltage 120 VAC Color Beige 4010-9102 Red 4010-9201 240 VAC Beige 4010-9202 Red 4010-9101C English French I ULC Listed 4010 Fire Alarm Control Panel; same as above except: with 24 LED Annunciator door; and without DACT 120 VAC Beige 4010-9101 CF 4010-9150 UL Listed ULC I English Listed French I 4010 Fire Alarm Control Panel electronics only, I for pre-shipped cabinets, requires door and cabinet ordered separately; -9150 has event reporting DACT 120 VAC NA 4010-9150C 4010-9150CF Optional Expansion Slot Features (two slots are available, select modules as required) Category Model Description Reporting and 4010-9810 4010-9816 DACT Module (Common Event Reporting) DACT Module (Point Reporting) Includes two, 7 ft (2.1 m) long RJ45 cables Network Modules (select one) 4010-9821 Network Interface Module with fixed, wired connections 4010-9817 Network Interface Module, Modular; requires 2 (In/Out) media modules (see below) RS-232 4010-9811 Dual RS-232 Interface Module Communications 4010-9812 Single RS-232 Interface Module with Service Modem connection (select one) Media Modules 4010-9818 Network Wired Media Module I Media modules mount on the 4010-9817 module I without impact to slot allocation space. 4010-9819 Network Fiber Optic Media Module Chassis Mounted Expansion Modules (select as required) Category Model Description Additional Power Supply (select one) 4010-9813 120 VAC input 4 A Expansion Power Supply 240 VAC input 4010-9823 4010-9814(CF) Suppression Release Power Supply; 4 A @24 VDC, regulated ± 10%; 120 VAC input 4010-9824 240 VAC input includes front panel suppression appliqué; CF suffix selects French Optional Features (select one) 4010-9820 4010 -9825 Battery Meter Module (ammeter and voltmeter) 24 VDC Expansion Power Distribution Module, provides two additional termination points for an expansion power supply tap or the auxiliary power output 4010-9806 Dual Circuit Class A (Style Z) NAC Adapter Module, two maximum Optional Features (select as indicated) 4010-9809 Dual Circuit City Connect Module Dual Circuit City Connect Module w/o disconnect switches Relay Option Module Select one maximum 4010-9829 4010-9803 Accessories Category Optional Features Model 4010-9826 Description - 120 VAC Auxiliary Relay Kit, allows one auxiliary relay to control up to 1/2 A @120 VAC, select as required; 2 maximum 4010-9830 (CAF) Suppression Release Appliqué, required for suppression release applications; suffix CAF selects a French appliqué 2975-9801 Semi-flush trim, beige, 1-7/16" (37 mm) wide 2975-9802 Semi-flush trim, red, 1-7/16" (37 mm) wide Batteries (required if batteries are internal; select one size; two batteries are required) 2081-9272 6.2 Ah Battery, 12 VDC 2081-9274 10.0 Ah Battery, 12 VDC 2081-9288 12.7 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC; NOTE: This battery size will not allow bottom entry conduit 2081-9287 25 Ah Battery, 12 VDC Cabinets (select one if pre-shipped) 2975-9215 Red Cabinet Dimensions: 22" H x 18" W x 5-3/8" 0 (559 mm x 457 mm x 137 mm) 2975-9214(CF) Beige Cabinet; CF suffix has French labels Doors (select one if pre-shipped or for use with 4010-9150) 4010-9858 Red Door with dress panel Dimensions: 22" H x 18" W x 5/8" D (559 mm x 457 mm x 16 mm) 4010-9857(CF) Beige Door with dress panel; CF has French labels 4010-9860 (CAF)* Beige Door with 24 LED Annunciator and dress panel; CAF suffix selects French for ULC applications Dimensions: 22" H x 18" W x 1-23/32"D (559 mm x 457 mm x i 44 mm) [see also S4010-0002] 40109861* 1 Red Door with 24 LED Annunciator and dress panel * As of document revision date: 4010-9829 is not ULC listed; 4010-9860 and 4010-9861 are listed by UL and ULC and approved by CSFM and FM; 4010-9860CAF is ULC listed and FM approved only. 6 54010-0001-9 10/2004 4010 Operating Specifications Input Power Requirements AC Input, 120 VAC base models Voltage Range 102 to 132 VAC Frequency 60 Hz Maximum Current 2 A AC Input, 240 VAC base models 204 to 264 VAC 50/60 Hz 1 A AC Input with 120 VAC expansion power supply 102 to 132 VAC 60 Hz 4 A AC Input with 240 VAC expansion power supply 204 to 264 VAC 50/60 Hz 2 A Environmental Operating Temperature Range 32° to 120°F (0° to 49° C) Operating Humidity Range up to 93% RH, non-condensing @ 100.4° F (38° C) maximum Output Ratings Standard Power Supply Output 4 A total @ nominal 28 VDC 1/2 A maximum of standard power Output switches to battery Auxiliary Power Tap supply voltage backup during mains failure or Additional 4 A @ nominal 28 VDC brownout conditions Additional 4 A @ 24 VDC ±10% Expansion Power Supply Output * Suppression Release Power Supply Output * * Each power supply provides two output taps of 2 A each. Current Ratings for Optional Modules and Remote LCD Annunciator Model 4010-9810 Module DACT (Common Event Reporting) Supervisory Current 40 mA Alarm Current 40 mA 4010-9816 DACT (Point Reporting) 40 mA 40 mA 4010-9821 Network, wired communications 125 mA 125 mA 4010-9817 Network Modular, add media cards separately 24 mA 24 mA 4010-9818 Network Wired Media 47 mA 47 mA 4010-9819 Network Fiber Optic Media 36 mA 36 mA 4010-9811 Dual RS-232 75 mA 75 mA 4010-9812 Single RS-232 with Service Modem 100 mA 100 mA 4010-9806 Dual Class A NAC Adapter 0 mA 0 mA 4010-9809 Dual Circuit City Connect 20 mA 36 mA 4010-9829 Dual Circuit City Connect w/o disconnect switches 20 mA 36 mA 4010-9803 Relay Option Module 10 mA 37 mA 4010-9860 4010-9861 & ULC 4010s 24 LED Annunciator door 60 mA 83 mA (all LEDs on) 4606-9101 Remote LCD Annunciator (refer to data sheet S4606-0001) 65 mA 140 mA System Current (supplied separate from power supply output) Base System with: no IDNet devices Supervisory Current** 195 mA Alarm Current** 295 mA 50 IDNet devices 230 mA 330 mA 100 IDNet devices 265 mA 365 mA 150 IDNet devices 300 mA 400 mA 200 IDNet devices 335 mA 435 mA 250 IDNet devices 370 mA 470 mA Current Calculation Information: To determine total supervisory current, add currents of modules in panel to base system value and all auxiliary loads. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all auxiliary loads. 7 S4010-0001-9 10/2004 4010 Module Layout Reference On' N2 , IDNOl NAC1 NAC2 NAC3 NAC4 TBIJ L4 MI 0 0; 10 4010-9806 4010-9806 Class A : Class A Module Module ©k :----------: II 4010-9820 Meter Module or -9829 or II: City Module : 4010-9825 or 24VDCPower 4010-9803 • Distribution II : Relay Module : Block ----------- ----------- 0 0 HI -------------- 4010-9813, 4098-9814 4010-9823, or 4010-9824 Expansion Power Supply ON Expansion Slots 1 & 2 MO o 0 0 0 0 0 0 0 0 -. i-;;;'•i (;;;- (;;;zt 0 0 pq y -lop 1111 0 0 Mounting Information / - —.: - - — - . Typ conduit entry area (cut holes as required) -18"(457 mm) PI 0. 2 eee®o®o©o )3 mm 14-1/2(368 mm) _P Battery Area No conduit entry or wiring in this area 0 Shaded area is for non-power limited wiring / 7-3/32 180 mm) Standard 1-19/32"---p door profile (40 mm) 6-1/4" J_(159 mm) - 3/4" Annunciator H- 5-1/2" (140 mm) (19 mm) door profile - Wall thickness guides for f-1 1/2" (13 mm) wall board Standard Door,, 5/8"(16 mm) thick all thickness guides for 5/8" (16 mm) wall board) Annunciator Door, Internal straps are -____ 1-23/32" (44 mm) thick provided for wiring management (2 each side) and exposed IDoor cabinet dimension......., for semi-flush mount 2-15/32" (63 mm) Knockout screw/nail holes (for semi-flush mount) Wall board position reference for semi-flush mount Tyco, Simplex, the Simplex logo, TrveAlar,,,, WALKTEST, IDNet, SmartSvnc, and TrueAleri are trademarks qiTyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks alike National Fire Protection Association (NFPA). .SimplexO Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4010-0001-9 10/2004 www.tycosafetyproducts-usa-wm.com 0 2004 Tyco Sq/iry Prothicts Westminster. All rights reser.,ed. All specifications am/ other infrniatio,i shown were current as qfdocvmeni revision date and ore subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7170-0026:226 Page 1 of 2 CATEGORY: Control Unit (High-Rise) LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models* 4010-9101, -9102, -9201, and —9202 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station (protected premises), proprietary (protected premise), waterfiow, and sprinkler supervisory service. Suitable for releasing device service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 4010-9101, -9102, -9201, -9202 4010-9150 4010-9809,-9829 4010-9810 4010-9816 4010-9817 4010-9821 4010-9806 4010-9811 4010-9812 4010-9813 4010-9814 4010-9818 4010-9819 4010-9820 4010-9823 4010-9824 2081-9046 4010-9860,-9861 4010-9803 Control Unit Standard Function I/O City Circuit Card Event Report DACT Point Report DACT Modular Network Interface RS485 Net Interface Class A Adapter Dual RS-232 Interface RS-232 Service Modem Expansion Power Supply Suppression Release Kit Wired Media Module Fiber Optic Media Battery Meter Module Expansion Supply Suppression Release Kit Coil Supervision Module Replacement Door with Annunciator Relay Module RATING: 120, 220, 240 VAC primary; 24 VDC secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING Listee's name, model number, electrical rating and UL label. *Rec 03-29-2006jw Listing No. 7170-0026:226 Page 2 of 2 APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Suitable for high-rise application when installed with model 4003 Series Voice Evacuation System (CSFM Listing No. 6911-0026:196). Refer to listee's Installation Instructions Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1) For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2) Formerly 7165-0026:226 *Recert 03-29-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division £5Simplex Rechargeable, sealed lead-acid design: Lead-calcium grid structure Immobilized electrolyte in absorbent separator High reliability dual seal construction Low maintenance, no need to add water Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities: Batteries for internal mounting range from 6.2 Ah up to 50 Ah, depending on control panel cabinet size For applications requiring 110 Ah batteries: Refer to data sheet S4081-0002 for 4100U systems Refer to data sheet S2081-0012 for 4100/4120 series system i '.fr1 Simplex® rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see illustration on page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. Fire Alarm Control Panel Accessories Cabinet Mounted System Batteries; 2081 Series, Sealed Lead-Acid; 6.2 Ah to 50 Ah Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets I:i.17Tm1i7jj Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through your local Simplex product supplier.) Specification Summary Nominal Voltage Rating 12 V/battery Discharge Rating 20 Hour Rate Typical Chart/Discharge Cycles 100 to 150 Preferred Charge Temperature Range j 60° F to 90° F (15.6°C to 32.2° C) These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact your local Simplex product supplier for proper battery selection per system requirements. S2081-0006-16 9/2004 Typical Construction Details Actual appearance will vary with battery size. t%I •4P t't% flr Battery Specifications BatteryModóI Capacity @:;P Width Depth* Height with Approximate Discharge Rate Terminals I Weight".. 2081-9272 6.2 Ah 6-1/8" (156 mm) 2-5/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 Ah 6" (153 mm) 4-1/16" (103 mm) 4(102mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 Ah 6" (153 mm) 4(102mm) 4(102mm) 9 lbs (4.1 kg) 2081-9275 18 Ah 7-1/4" (184 mm) 3-3/8" (86 mm) 6-5/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 Ah 6-5/8" (168 mm) 5(127mm) 7(178mm) 19.4 lbs (8.8 kg) 2081-9271 - (rectangular case, 33 Ah 12-1/2" (318 mm) 3-3/8" (86 mm) 7-1/16" (179 mm) 26.6 lbs (12.1 kg) typically for service) 2081-9276 ("square" case, 33 Ah 7-3/4" (197 mm) 5-1/4" (133 mm) 6-3/4"(171 mm) 26.5 lbs (12 kg) use for new) 2081-9296 50 Ah 9-1/2" (241 mm) 5-1/2" (140 mm) 8-7/8"(225 mm) 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. NOTE: When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Battery Simplex Control Panel Model Series (see legend and notes below) Model Capacity :T!..4006 & 4009 41OOU 4b0&4120 4020 4603 0 005 40O8. (allmodets) 4010 .(20r3bay) (2,40r6-Unit) (2,40r6-Unit) 2081-9272 6.2 Ah 1 1 1 1 1 1 1 1 1 1 2081-9274 10Ah 1 1 1 1 1 1 1 1 1 1 2081-9288 12.7 Ah / I I 1 1 1 1 1 2081-9275 18 Ah I Note 3 1 Ext Ext Note 2 / 1 / 2081-9287 25 Ah Note Ext Ext 2081-9271 33 Ah Note 3 Ext Note 3 1 Ext Note 4 (rectangular) 'u7 33 Ah Note 3 Ext Note 3 1 1 Ext e 2081-9296 50 Ah - Note 3 - Note 3 / Ext Ext / = Can be placed in the respective equipment cabinet Ext = External battery cabinet is required, refer to selection chart on page 4 Shaded areas = Not applicable NOTES: These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact your local Simplex product supplier for proper battery selection per system requirements. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. Use 4081 series companion cabinet and charger, refer to page 4. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. Some control panel models are listed for battery replacement reference only. 32081-0006-16 9/2004 External Battery Cabinet Compatibility Reference Externally Mounted Battery Battery Cabinets without Chargers Battery * Capacity Cabinets with Chargers (connects to charger in panel) 4081 Model 20811-9301— 20814303" Serlest 2081-9270 2081-9281 2081-9282 4009-9801 4009-9802 2081-9275 18 Ah 2081-9287 25 Ah 2081-9271 (rectangular) 33 Ah 2081-9276 If If 1 (square') 2081-9296 50 Ah * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. /= Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specification Reference Model DescripfflOFF. Color Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25-3/4" W x 20-3/4" H x 6-3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 2081-9270 External battery cabinet without charger Red 26-1/2" W x 12" H x 12" D (673 mm x 305 mm x 305 mm) 2081-9301 External battery cabinet with charger 2081-9302 External battery cabinet without charger and with meters for voltage and current 2081-9303* External battery cabinet with charger and with meters for voltage and current 4009-9801 For up to 18 Ah External battery cabinet without charger, 16-1/4" W x 13-1/2" H x 4-1/8" 0 batteries with solid door and battery harness, for close-nippled mounting to fire alarm control Beige ig (413 mm x 343 mm x 105 mm) For up to 33 Ah 25-3/4" W x 20-3/4" H x 4-1/8" 0 4009-9802 batteries panel cabinet (654 mm x 527 mm x 105 mm) 4081 For up to 50 Ah Companion cabinet with charger for the Beige or 22-1/2" W x16-3/4" H x 8-3/8" D Series** batteries 4010 and 4004R fire alarm control panel Red (572 mm x 425 mm x 213 mm) * Refer to Simplex data sheet S2081-0002 for additional information. ** Refer to Simplex data sheet S4081-0001 for additional information. Tyco, Simplex, and the Simpler logo are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or oilier countries. O Tyco Safety Products Westminster• Westminster, MA • 01441-0001 USA S20981-0006-16 9/2004 ,Simplex www.tycosafetyproducts-usa-wm.com 0 2004 Two Safety Products Westminster. All rights reserved. All specifications and other information shown here current as ofdocument revision date and are subject to change without notice. £5Simplex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET Il® and IDNetTM Communicating Devices, and MEA (NYC) Approved* Individual Addressable Module (lAM) 4090-9001 MAPNET II or IDNet addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from UM to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex 2081-9044 Overvoltage Protectors for outdoor or electrically noisy applications Compatible with Simplex: 6Simpl SIOPLEX TINE l[CORD(p CO. 4090 -90o I SRyisg 0 OI. 1154. 514131 DATE CODE 2 011 Model Series 4010/4100/4120/4020 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 communicating device transponders (CDTs) equipped with MAPNET II communications srirtic 4090-9001 Supervised lAM (shown approximately full size) Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Provides current limited monitoring (for use with IDNet communications): To monitor tamper switch (trouble) and waterfiow switch (alarm) on same circuit using one point Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be latched, such as from rate-of-rise heat detectors UL listed to Standard 864 This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300.0026223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact Simplex for the latest status. MAPNET It and IDNet addressable communications designs are protected by U.S. Patent No. 4,796,025. The 4090-9001 is an individual addressable module (JAM) with both power and communications supplied by a two-wire MAPNET 11 or IDNet circuit. It provides location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Closure of the monitored contacts initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not applicable with 2120 CDT). For use with IDNet communications only, the 4090-9001 can sense normal, open circuit, short circuit, and current limited conditions. With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. © 2000 Simplex Time Recorder Co. All rights reserved. S4090-0001-4 8/00 N lAM Module '\odel Number Description 4090-9OO1 Supervised lAM module Optional Trim Plates and Mounting Bracket Model Number Description 4090-9806 Trim plate with LED viewing window, requires 4090-9810 For semi-flush mounted box 4090-9807 mounting bracket, includes mounting screws For surface mounted box 4090-9810 Mounting bracket, mounts lAM to electrical box and provides screw holes for trim plate, required for optional trim plates OWNTM, M, 0 Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per lAM Input Requirements Normally open, dry contacts Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire Supervision Resistor 6.8 k.Q, 1/2 W NOTE: Refer to installation instructions 574-331 and field wiring diagrams 1.8 kQ and 4.7 kL, 1/2W 841-804 and 842-073 for additional information. Resistors for Current Limited Operation (for use with IDNet communications only Wiring Distances Distance from lAM to Contacts . 500 ft (152 m) maximum without protectors 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance, MAPNET II or IDNet, 2500 ft (762 m) maximum from fire alarm control panel per Channel 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 19/16" W x 13/4" H x 1 1/4" D (40 mm x44 mm x 32 mm) Housing Material I Black thermoplastic Temperature Range 1 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RHat 100° F (38° C) Simplex Time Recorder Co. 2 S4090-0001-4 8/00 Mounting Information 4090-9001 IDNet supervised lAM 411, DAIE CODE: WIN i14 Field wiring shown for reference o LED viewing port Single gang electrical box 2 1/2" (64mm) minimum depth (supplied by others) Address setting under resealable label Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 41/4" I I Ught pipe for (108 mm) I I I I H LED viewing PC 11) 2 1/2" (64 mm) 4090-9806, Trim plate for semi-flush mounted box _________ 2 13/16" (72 mm) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED Simplex Time Recorder Co. 3 S4090-0001-4 8/00 Simplex, the Simplex logo, MAPNETII, and IDNet are either trade,narks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. S4090-0001-4 8/00 93,Simplex Westminster, Massachusetts 01441-0001 USA visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 9 OFFICE OF THE STATEFIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:223 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -91O6TSP, and -9106TTP Class "A" ZAM Initiating Module; 4090-9101, -9101TSP, and -9101TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use y. Refer to listee's Installation Instruction Manual for details. *Recel.t 03-29-2006 jw TI "'• This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division License Number: 802591 Extract Date: 10/01/2008 SIMPLEX GRINNELL L P Business Information: 900 ALLEN AVENUE GLENDALE, CA 91201 Business Phone Number: (561) 988-3755 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2009 License Status: This license is current and active. All information below should be reviewed. li]*IIlllLI] Classifications: CIO ELECTRICAL C16 FIRE PROTECTION CONTRACTOR This license filed Contractor's Bond number 81880913 in the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2007 Contractor's Bonding History This license filed Bond of Qualifying Individual number 82056155 for KARIM MAZHAR in Bonding: 1. the amount of $12,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2007 BQI's Bonding History This license filed Bond of Qualifying Individual number 81880915 for RONALD GILBERT MAYLE in the amount of $12,500 with the bonding company FEDERAL INSURANCE 2. COMPANY. Effective Date: 01/01/2007 BQI's Bonding History This license has workers compensation insurance with the AMERICAN HOME ASSURANCE COMPANY Policy Number: WC1616749 Workers' Compensation: Effective Date: 06/29/2008 Expire Date: 10/01/2008 Workers' Compensation History Miscellaneous Information: uiy..0 I']illJl[.] 10/28/2005 ASB CERTIFICATION REMOVED tqccs IF/re & I Security l SimplexGrinnell SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:0013M, MONDAY THROUGH FRIDAY, EXCLUDING .( LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. 12/27/2007 REV.#: 0 PROJECT #: 480-XXXXXX-XX I XXXXXXXXX NFPA Record of Completion Name of Protected Property ENCINA WASTEWATER Address 6200 AVENIDA ENSINAS CARLSBAD Rep. of Protected Property (name/phone) Authority Having Jurisdiction Address / Phone Number Type(s) of System or Service: X NFPA 72, Chapter 3 - Local if alarm is transmitted to location(s) off premise, list where received: INTERGRATED ALARM SYSTEMS NFPA 72, Chapter 3 - Emergency Voice /Alarm Service: Quantity of voice/alarm channels Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in the system: NFPA 72, Chapter 4 - Auxiliary Indicate type of connection: Local Energy, __ Shunt, R Location and telephone number for receipt signals: Parallel Telephone NFPA 72, Chapter 4 - Remote Station Alarm: Supervisory: X NFPA 72, Chapter 4 - Proprietary If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving alarm: INTERGRATED ALARM SYSTEMS 1760-598-4110 Indicate how alarm is retransmitted: NFPA 72, Chapter 4 - Central Station: The prime contractor: INTERGRATED ALARM SYSTEM Central Station Location: San Diego Means of transmission of signals from the protected premise to the central station: Mculloh Multiplex One-Way Radio Digital Alarm Communicator Two-Way Radio Others Means of transmission of alarms to the public fire service communications center: System Location: Organization Name I Phone Representative Name I Phone Installer SimplexGrinnell Bob Ciereck 858-740-0100 Supplier Simplex Grinnell Mark Walker 858-740-0100 Service Organization SimplexGrinnell Steve Schwartz 858-740-0100 Page 1 of 1 NFPA Record of Completion (1996 ed.) Location of (As-Built) Drawings: ENSINA WASTEWATER Location of Owners Manuals: Same Location of Test Reports: A contract, dated for test and inspection in accordance with NFPA standard(s) No(s), dated ,is in effect. Record of System Installation (Fill out after installation is complete and wiring checked for opens,shorts,ground faults and improper branching but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below,was inspected by SimplexGrinnell on , includes the devices shown below and has been service since x x x NFPA 72, Chapters 1 3 4 5 6 7 (Circle all that apply) NFPA 70, National Electric Code ,Article 760 Manufacturer's Instructions Other ( Specify) Signed: CARLOS HERRERA Date: Organization: SimplexGrinnell 3. Record of System Operation All operational features and functions of this system were tested by SimplexGrinnell Date: and found to be operating properly in accordance with requirements of: X NFPA 72, Chapters 13 4 5 6 7 (Circle all that apply) X NFPA 70, National Electric Code ,Article 760 X Manufacturer's Instructions Other ( Specify) Signed: CARLOS HERRERA Date: Organization: SimplexGrinnell 4. Alarm Initiating Devices and circuits (Use blanks to indicate quantity of devices.) Manual Manual Stations Noncoded,Activating Transmitters Coded Combination Manual Fire Alarm and Guard's Tour Coded Stations. Automatic Coverage: Complete Partial Smoke Detectors Ion Photo Duct Detectors Ion Photo C) Heat Detectors FT RR FT/RR RC I Sprinkler Waterfiow Switches Transmitters Noncoded,Activating Coded I Other(list): P.I.V 5. Supervisory Signal Initiating Devises and Circuits (Use blanks to indicate quantity of devices.) Guard's Tour Coded Stations Noncoded Stations Activating Transmitters C) Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Sta Note: Combination devices recorded under 4(b) and 5(a). Page 1 of 2 NFPA Record of Completion Sprinkler System Coded Valve Supervisory Signaling Attachments Valve Supervisory Switches Activating Transmitters Building Temperature Points C) Site Water Temperature Points Site Water Supply Level Points Electric Fire Pump: Fire Pump Power D Fire Pump Running Phase Reversal Engine Driven Fire Pump: Selector in Auto Position Engine or Control Panel Trouble D Fire Pump Running Engine Driven Generator: k) Selector in Auto Position I) Control Panel Trouble Transfer Switches _Engine Running Other Supervisory Function(s) (Specify) 6. Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: Bells Inch Speakers C) Horns Chimes Other: Visual Signals Type: Xenon with audible w/o audible Local Annunciator Admin Lobby Signaling Line Circuits: Quantity and Style (See NFPA 72, Table 3-6) of signaling line circuits connected to the system. Quantity: 2 Style: V 8. System Power Supplies Primary (Main): Nominal Voltage: I20VAC Current Rating: Overcurrent Protection: Type: Circuit Breaker Current Rating: Location: Secondary (Standby): X Storage Batteries Amp-Hour Rating Calculated capacity to drive system, in hours: X 24 60 Engine driven generator dedicated to fire alarm system: N/A Location of fuel storage: Emergency/Standby System used as backup to Primary Power Supply, instead of useing a secondary Power supply: Emergency System described in NFPA 70, Article 700 Legally Required Standby System described in NFPA 70, Article 701 Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 Page 1 of 1 NFPA Record of Completion 9. System Software Operating System Software Revision Level(s): Application Software Revision Level(s): Revision Completed by: (name) (firm) 10. Comments: (signed ) for Central Station or Alarm Service Company (title) (date) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): NOT IN CONTRACT System deviations from the referenced NFPA standard(s) are: NONE (signed) for Central Station or Alarm Service Company (title) (date) satisfactory authority having 7tion) Agnecdo) tive of the authority jurisdic on Page 1 of 1