Loading...
HomeMy WebLinkAbout7113 AVIARA DR; ; AS080098Balance ($) 0 City of Carlsbad Sprinkler Permit Permit No: AS080098 Job Address: 7113 AVIARA DR Status: ISSUED Permit Type: SPRINK Applied 6/24/2008 Parcel No: 2156103300 Approved: 6/26/2008 Lot #: 0 Reference No.: Issued: 6/26/2008 PC #: Inspector: Project Title: MORGANNILKUTAITIS RESIDENCE 3 FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: Owner: INNOVATIVE FIRE PROTECTION VILKUTAITIS RUDOLPH&MORGAN MARSHA IJ SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 6/4/2008 C:\HASS78\C3951.SDF JOB TITLE: MORGAN / VILKUTAITIS RES. - TWO HEAD CALC - GREAT ROOM WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 85.0 80.0 500.0 85.0 31.0 57.3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 275.0 SOURCE 57.3 31.0 2 275.0 - - - - 51.7 - - - 2A 275.0 - - - - 47.7 - - - 3A 275.0 HOSE STREAM 45.8 5.0 Cl 276.0 - - - - 43.8 - - - C2 276.0 - - - - 36.8 - - - 3B 275.0 - - - - 35.1 - - - 3 276.0 - - - - 33.0 - - - 4 279.0 - - - - 30.0 - - - 5 286.0 - - - - 23.6 - - - 6 297.0 - - - - 11.9 - - - 7 294.5 - - - 9.1 - - - 7A 294.0 K= 4.30 9.1 13.0 8 294.5 - - - - 9.1 - - - 8A 294.0 K= 4.30 9.1 13.0 APPROV D 64 SUBMITTED CAR1i FI DEPARTMENT These plans have been reiewed for apparent coiiiplwwe with the current applicable codes and standards in foive iithe jurisdiction. The owner or foI1iracIor may uiiliie this review in support of an application fora building Jsrmit with the express unJerstanding that this review in no way relieves the owner or contractor or their professional engineer or awhile V1 for sole itspnnsihility for full compliance with said codes and standards. including the buildingcodc o I'm any responsihilty fir deficiencies. errors. 61nissions or negligence in these plaits whether or not noted in this review. Date: //og cviewer:) CSRE.Z)MMENI) APPROVAl. 13 RECOMMEND APPROVAL. AS NOTED SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/4/2008 C:\HASS78\C3951.SDF JOB TITLE: MORGAN / VILKUTAITIS RES. - TWO HEAD CALC - GREAT ROOM PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.0 0.995 PL 13.00 PF 5.5 1 275.0 SRCE 57.3 (N/A) 12.8 150 FTG TG PE 0.0 2 275.0 0.0 51.7 0.0 0.251 TL 22.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 275.0 0.0 51.7 0.0 4.0 psi, 31.0 gpm 2A 275.0 0.0 47.7 0.0 Pipe: 3 31.0 1.025 PL 2.00 PF 2.0 2A 275.0 0.0 47.7 0.0 12.1 150 FTG E2L PE 0.0 3A 275.0 H.S. 45.8 5.0 0.217 TL 9.00 PV Pipe: 4 26.0 1.025 PL 5.00 PF 1.6 3A 275.0 H.S. 45.8 5.0 10.1 150 FTG EL PE -0.4 Cl 276.0 0.0 43.8 0.0 0.157 TL 10.00 PV Pipe: 5 FIXED PRESSURE LOSS DEVICE Cl 276.0 0.0 43.8 0.0 7.0 psi, 26.0 gpm C2 276.0 0.0 36.8 0.0 Pipe: 6 26.0 1.360 PL 40.00 PF 2.1 C2 276.0 0.0 36.8 0.0 5.7 150 FTG E4L PE 0.4 3B 275.0 0.0 35.1 0.0 0.040 TL 53.00 PV Pipe: 7 26.0 1.265 PL 10.00 PF 1.7 3B 275.0 0.0 35.1 0.0 6.6 150 FTG 3E3L PE -0.4 3 276.0 0.0 33.0 0.0 0.056 TL 31.00 PV Pipe: 8 26.0 1.049 PL 3.00 PF 1.7 3 276.0 0.0 33.0 0.0 9.7 120 FTG C PE -1.3 4 279.0 0.0 30.0 0.0 0.211 TL 8.00 PV Pipe: 9 26.0 1.101 PL 10.50 PF 3.4 4 279.0 0.0 30.0 0.0 8.8 150 FTG 2ETR PE -3.0 5 286.0 0.0 23.6 0.0 0.111 TL 30.50 PV Pipe: 10 26.0 1.101 PL 38.00 PF 6.9 5 286.0 0.0 23.6 0.0 8.8 150 FTG 3E3R PE -4.8 6 297.0 0.0 11.9 0.0 0.111 TL 62.00 PV Pipe: 11 12.6 1.101 PL 71.00 PF 3.9 6 297.0 0.0 11.9 0.0 4.3 150 FTG 6E4TR PE 1.1 7 294.5 0.0 9.1 0.0 0.029 TL 134.00 PV Pipe: 12 13.0 1.101 PL 0.50 PF 0.2 7 294.5 0.0 9.1 0.0 4.4 150 FTG TR PE 0.2 7A 294.0 4.3 9.1 13.0 0.031 TL 6.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/4/2008 C:\HASS78\C3951.SDF JOB TITLE: MORGAN / VILKUTAITIS RES. - TWO HEAD CALC - GREAT ROOM PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -0.4 1.101 PL 16.00 PF 0.0 7 294.5 0.0 9.1 0.0 0.1 150 FTG E2R PE 0.0 8 294.5 0.0 9.1 0.0 0.000 TL 25.00 PV Pipe: 14 13.0 1.101 PL 0.50 PF 0.2 8 294.5 0.0 9.1 0.0 4.4 150 FTG TR PE 0.2 8A 294.0 4.3 9.1 13.0 0.031 TL 6.50 PV Pipe: 15 -13.4 1.101 PL 63.00 PF 3.9 8 294.5 0.0 9.1 0.0 4.5 150 FTG 6E3TR PE -1.1 6 297.0 0.0 11.9 0.0 0.032 TL 121.00 PV NOTES (HASS): Calculations were performed by the HASS 7.9 computer program under license no. 16080621 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.074 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.8 ft/sec at pipe 1. PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: A MATERIAL: SCH40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 1.00 1.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/4/2008 C:\HASS78\C3951.SDF JOB TITLE: MORGAN / VILKUTAITIS RES. - TWO HEAD CALC - GREAT ROOM PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 1.265 5.00 9.00 2.00 11.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.360 5.00 9.00 2.00 11.00 6.00 2.00 0.00 0.00 PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.50 0.50 3.00 0.00 0.00 E I 0. I Wa' b'OU I c ,.i W I •.-ic I oz ul .-4r-4 0..(I I LI) 1x1 WCU)(fl0 I .i W 0 W I 0. 1 —Iu)•0oW I o .00.W0.41 I NO>, I .-O'C'JCf)U) I >WN . I Cl) co w Lo 71A 71A m 71A cn 04 I C YA 0 C) 0 D D D D I SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/4/2008 C:\HASS78\C3951.SDF JOB TITLE: MORGAN / VILKUTAITIS RES. - TWO HEAD CALC - GREAT ROOM SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/4/2008 C:\HASS78\C3951.SDF JOB TITLE: MORGAN / VILKUTAITIS RES. - TWO HEAD CALC - GREAT ROOM WATER SUPPLY CURVE FEATURES 3/4' to 2' C1 Double check valve assembly consisting of two independently operated spring-loaded 'Y° type center guided check valves C) Complete with two full port resilient seated ball valves for shut-off and four resilient seated ball valve test cocks o Bronze body construction .0 Entire unit serviceable in-line MODEL 950 C] Replacable seat option available 0 Available with BSP - threads (less shut-off valves) O Maximum operating pressure: 175 psi O Temperature range: 33°F to 140°F O STANDARDS: ASSE (No. 1015), IAPMO®, AWWA, GSA B64.5, USC/FCCC & HR OPTIONS Model 950XL Same as 950 except supplied with Noryl replaceable seats and silicone rubber check discs. (temperature range 33°F to 180°F). Model 950L Same as 950 except supplied less shut-off valves. Model 950LXL Same as 950XL except supplied less shut-off valves. Model 950S Same as 950 except supplied with "Y" strainer. Model 950XLS Same as 950XL except supplied with'Y strainer. Model 950U Same as 950 except supplied with union connections between ball valves and the device. Model 950US Same as 950U except supplied with "Y' strainer. Model 950XLU Same as 950XL except supplied with union connections between ball valves and the device. Model 950XLUS Same as 950XLU except supplied with UyII strainer. 22 C, Li U) 0. U) 15 2. U) Cl) 0 10 -J 'Ii a: D5 U) U, Ui a: 0.0 DIMENSIONS & WEIGHTS DIMENSIONS (In.) WEIGHT (lbs.) MODEL A A SIZE BALL DOUBLE UNION LESS LESS WITH BALL BALL BALL VALVES BALL VALVES VALVES C 0 E F VALVES VALVES 4 11.12 12.50 7.00 3.10 2.77 2.87 1.22 4.80 6.47 1 12.37 13.75 7.00 3.10 2.77 2.87 1.22 4.80 7.75 11/4 17.00 N/A 10.57 4.40 4.33 3.50 1.98 11.13 16.75 11/2 17.62 19.12 10.57 4.40 4.33 3.50 1.98 11.55 18.30 2 18.25 20.00 10.57 4.40 4.33 3.50 1.98 11.92 23.05 A FLOW CHARACTERISTICS - AMERICAN STANDARD . METRIC STANDARD ICU U) 0 U IS U) (I) O 10 -j w a: D 5 U) U) Lii a: 0.0 I CU a. .90 U) U, 0 60 cc cn cn 30 a: 0. n 0 10 20 30 40 50 60 o 1 2 3 4 FLOW RATE (U.S. GPM) FLOW RATE (L/S) a. .90 U) U) 0 ul 60 a: D C') 30 a: 0. 0 0 40 80 120 160 200 240 0 s qn is FLOW RATE (U.S. GPM) FLOW RATE (US) 23 Ja 0 bli A Concealed Residential Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2-1/2" (13mm) Total adjustment. Push-On/Thread-Off cover attachment option. Smooth aesthetic ceiling profile. Available in brass, chrome and black plated or painted finishes. Listings & Approval Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) PsOoW Bulletin 006 Rev.A CO Model RFC43 Concealed a . Residential Sprinkler (SIN RA0612) UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC43 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 Sprinkler provides the best form of fire protection by combining an attractive appearance and W' (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC43 is a UL Listed Residential Sprinkler to be installed in the residential portions of any occupancy in accordance with NFPA 13,13R, & 13D. The RFC43 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC43, for residential installations, uses a 165°F (74°C) fusible solder link in a tuning fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler Tho PIhahIø Au.tnmitir qnrinklar (n Inr cc Nnrth lA flu uctn PrkAl, lAruuint \/rnnn McAl Yrurk 1I12 inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 5/8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLERXUP ASSEMBLY. MODEL RFC43 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Cover assemblies provide up to )2" (13mm) of adjustment Turn the cover clockwise until the flange is in contact with the ceiling. The optional push-on cover plate may require a final adjusting turn to contact the ceiling. Cover removal requires turning in the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment Temperature Rating Sprinkler Cover Plate Max. Ambient Temp. 165°F174°C I 135°F157°C 100°F138°C Installation Data Thread Size I inch (mm) K Factor Sprinkler Spacing ft. (m) Maximum Distance to Wail ft. (m) Minimum Distance between sprinkler ft. (m) Minimum Required Sprinkler Discharge How Press. gpm (Lpm) psi (bar) I 1/"(15mm) 4.3 12x 12(3.6x3.6) 6(1.83) 8(2.43) 12(45) 7.8 (0.54)1 ½" (15mm) 4.3 14 x 14 (4.3x4.3) 7(2.13) 8(2.43) 13(49) 9.1 (0.63)1 ½" (15mm) 4.3 16 x 16 (4.9x4.9) 8(2.43) 8(2.43) 13(49) 9.1 (0.63) 1/2"(15mm) 4.3 18x 18(5.5x5.5) 9(2.74) 8(2.43) 18(68) 17.5(l.21) Y" (15mm) 4.3 20 x 20 (6.04.0) 10(3.05) 8(2.43) 21(79) 23.8 (1.64) Note: 1 bar = 100 Kpa Model RFC 43 Pendent Flat Concealed installed below Sloped Ceiling. ,•__I____I r& I I II ,icu IJULU Thread I i Sprinkler Temp. Rating I Coverplate Temp. Rating I Max. I Pressure Max. Ambient Temp. Actual J K Factor I Max Adjustrnent Sprinkler identification Size o (°C) °j°C) j psi (b)_ -. °F (°C) (metric) Number (S!!Lj Y2"NPT(RV2) I 165(74) I 135(57) 175(I2L 100(38) I 4.3(61,4) I Y2' I RA0612_ Tftkl 12 -A H atinn Max. Sprinkler Spacing Along Slope (W) Width x ( L) Length ft (m) —rr Max. Slope of 542 (33.7 Pitch Max. Slope of %2 (18.4°) Pitch Mm. How Per Sprinkler Head gpm (Lpm) - Pressure psi (bar) Mm. Flow Per Sprinkler Head gpm (Lpm) Pressure _p (bar) 12 x 12(3,6 x 3,6) 18(68) 17.5 (1,21) 13 (49) 9.1(0,63) 14 x 14 (4,3 x 4,3) 18(68) 17.5(1,21) 13(49) 9.1(0,63) 16x 16(4.9x4,9) 18(68) 17.5(1,21) 13(49) 9.1(0,63) 18 x 18(5,5 x 5,5) 21(79) 23.8 (1,64). 20 x 20 (6,1 x 6, 1) - 21(79) _L. 2. .:3d. .3OO Maintenance Model RFC43 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. 135°F (570C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange having a [thread-on] [push-on] and thread-off design, allowing a ½" cover plate adjustment Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to. protect the drop-down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty - specify]. Residential concealed sprinklers shall be Reliable Model RFC43, SIN RA0612 (Bulletin 006). Model RFC43 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential concealed sprinklers with drop-down deflector and adjustable flat cover plate engineered for a minimum design density of 0.05 gprrtt2. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NFl thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K-factor shall be nominal 4.3(62.4), having a 7/16" orifice. Temperature rating shall be Ordinary 165°F (741C); cover plate temperature rating to be Ordering Information Specify: Sprinkler Model Cover Plate Finish Thread-On or Push-On cover Cover Plate Finishes"' Standard Finishes Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome "Other colors and finishes available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. I • x r/2" REDUCING TEE OR ELBOW -1 J_ -----us---- (58.7mm] 0/A -. ' ? r [66.7mm] 014. _ HOLE IN CEILING Cup 2 [50.8mm] MAX. FACE OF PITTING TO FACE OF CEILING DIMENSION CErLING -I ' (12.7mm] MAX. COVER AWUSTMENT J COVER PLATE_.I ASSEMBLY 3fDL4. I 3/16 (84.1mm] (4.8mm] COVER PLA iF: 1/2 (12.7mm 1 ADJUSTMENT 3. A663MW Bulletin 135 Rev.D — i able Model Residential Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gprMt Sprinklers Types: F1 Res 49Pendent Fl Res 49 Recessed Pendent/F 1 Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Pendent/Fl Fl Res 49 CCP Pendent 7.F1 Res 44HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSW Recessed HSW/F2 F1 Res 44SWC 12.F1 Res 40HSW 13. Fl Res 40 Recessed HSW/F2 Fl Res 49&58 Recessed Pendent/ Fl Fl Res 49 Recessed Pendent/FP Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the. Model Fl Res 49 & 58 Pendent Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2,3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers (Figs. 5,6 & 7) are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers, with a K-Factor of 4.9, permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard *)• Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Fl Res 49CCP Fl Res 44 & 58 Pendent Recessed HSW/F2 Fl Res 44 SWC Fl Res 40 Recessed HSW/F2 Technical Data: Thermal Sensor: Nominal 3mm glass-bulb Sprinkler Frame Brass Casting Sprinklers' Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: 1/2" NPT ® 1/4 K-Factor 4.9 (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (Actual) - Fl Res 58 Pendent & HSW Sprinkler 4.4 (Actual) - Fl Res 44 HSW Sprinkler 4.0 (Actual) - Fl Res 40 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Application Model Fl Res Sprinklers are used for Residential Fire Protection according to UL 1626 Standard*. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. * Effective date 7/12/02 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR1 sprinkler wrench; for installing Model Fl Res Recessed HSW sprinklers use only the Model GFR1 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 and 40 HSW with a ceiling to deflector distance of 4"- 12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling. Model F1 Res 49&58 Model Fl Res 49 & 58 Pendent Recessed Pendent I Fl Fl escutcheon, y4" (19mm) adjustment 'II Fig. 1 Fig.2 PA Technical Data: Fl Res 49 Pendent and Recessed Pendent Thread Sprinkler Temp. Max. Max. Ambient Actual Sprinkler Size Rating Pressure Temp. K Length psi (bar) Factor inch (mm) OF OC y"NPT (AX) 155 I 175 68 I 79 175 (12)150 100 66 I 38 4.9 2.25 (57) Esc utcheonFl or F2, Data: Adjustment "A" Facec(fittingto Type Inch (mm) Inch (m) ceiling Inch(mm) Fl %(19.0) Min.= Y4" (19.1) Max.=1j4(38.1) /16 %(4.7-240) F2 X(12.7) Min.= 1s6 (23.8) Max.=1X"(38.1) x6 - 'X6 (4.7-17.4) I * Note: Escutcheons Fl or F2 may be used with Model Fl Res 49 & 58 Recessed Pendent Spnnkler MaXRnUm 1" (nm) W'W' (lUXTIn) Max. Sprinkler Spacing It (m) Flow gpm (1pm) Pressure psi (bar) um Sprinkler Identification N (SIN) 12x 12(3.6x3.6) 13(49) 7.0(0.48) R3516 16.7(1.14) 14 x 14 (4.3x4.3) 13(49) 7.0(0.48) 16x 16(4.9x4.9) 13(49) 70(0.48) 18 x 18 (5.5x5.5) 17(64.3) 12.0(0.83) 20 x 20 (6.1x6.1) 20(75.7) -10- ciOng Maximum 4" (10()Tim) 10 8" (203mm) Max. Sprinkler Spacing ft (m) Flow gpm (1pm) Pressure psi (bar) Sprinkler Identification Number (SIN) 12 x 12 (3.6x3.6) 15(57) 9.4 (0.65) R3516 20.2(1.4) 14 x 14 (4.3x4.3) 16(60.5) 10.6(0.73) 16 x 16 (4.9x4.9) 17(64.3) 12.0(0.83) 18 x 18 (5.5x5.5) 19(72) 15.0(1.0) 20 x 20 (6.1x6.1) 22(83.2) *Nte The Fl Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: Maximum beam depth = 7" (178mm) Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: Fl Res 58 Pendent and Recessed Pendent Thread Sprinkler Temp. Max. Max. AItthleIt K Sprinkler Size Rating Pressure Teip Factor 15(19th psi (bar) Inch (mm) I -OF i OF 0 WNPT (RY2) 1551 1751 68 79 175(12) 1001 38 5.8 2.25 (57) Max. Sprinkler How Pressure Ceiling-b- Sprinkler Spacing ft (m) gpm( psi (bar) D Inch (mm) kl Number(SIN) 12 x 12 (3.6x3.6) 16 (61) - 7.6(0.53) 1-4 (25-100) A3513 14x 14(4.3x4.3) 16(61) 7.6(0.53) 16x 16(4.9x4.9) 16(61) 7.6(0.53) 18 x 18 (5.5x5.5) 19(72) 10.8(0.75) 20 x 20(6.1x6.1) 22(83.3) 14.4(l.0) 3. Model Fl Res 49 CCP Model Fl Res 49 Recessed FP push-on/thread-off escutcheon 2 5/8 (66.7mm) OLL. 2 51f6' 014. HOLE IN CEILING Cup ii 11, /2 REDUCER CUP CEILING I I/4 31.5mm) MAX. FACE 01 FIT17NG - TO FACE 01 CEILING j COVER AO.IUS7WENT HEIGHT I 35/I6OL&_,.I (84. Immj Fl RES 49 CCP PEND. _2 4( ,W All CUM 2 5116- OK (6a7 a., rr s, aaft Fig.3 Fig.4 Technical Data: Fl Res 49 CCP and FP CCP ODtions Data: 5- CCP Assembly Max Max. Sprinkler Thread Size Tetip. Rating Temp. Rati Pressure Ambient Temp,Length K Factor ng psi (bar) inch OF O( °F IOC 1/2NPT 155168 1351 57 75() 1001 150 38 I 66 4.9 2.25(57) Max. Sprinkler Spacing ft (m) Flow Pressu psi (ba) Sprinkler 12 x 12 (3.6x3.6) 13(49) 7.0(0.48) R3516 16.7(1.14) 14 x 14 (4.3x4.3) 13(49) 7.0(0.48) 16 x 16 (4.9x4.9) 14(53) 8.2(0.56) 18x 18(5.5x5.5) 18(68.1) 13.5 (0.93) 20 x 20 (6. 1 x6. 1) 20(75.7) "B" Cover Adjustment CCP Height Inch (mm) Inch (mm) j/2 (12.7) 4(24) - -3/4 (19) FP Data "A": FP Position ll I A Inch (mm) I Max. Recessed Y, (11) 1 Mm. Recessed % (24) Note: Spiinders shown in Hg. 3 and 19g. 4 are not suitable for nistaon in ceilings whkh have Positive pressure in the space above. 4. Model F1 Res 44 & 58 HSW Model F1 Res 44&58 Recessed HSWIF2 F2 escutcheon, " 03mm Technical Data: Fl Res 44 HSW & HSW/F2 Escutcheon, F2, Data: Type Adjuatment I Face of Fitting 1 to _J I Inch (mm) uncim) I F2 )i3) Ie%(4.717.4) Thread Sprinkler Temp. Max. Max Ambient K Spunkier Size Rating Pressure Ten Factor Length psi (bar) Inch(m) W'NPT (RY2) 155 175 68 I 175(12) 100 150 I 38 I 66 4.4 2.45(62) Max. Sprinkler Spacing ft (m) Calling -to- DeflOCtDr Inch(mm) " A"Sprinider Ten Rating CF (°C) Flow gI.pm) Pressure psi (bar) Sprinkler Number(SIN) 12 x 12 (3.6x3.6) 4-6 (101-152) 155(68) 175(79) 12(45.4) 7.5(0.52) R3531 14 x 14 (4.3x4.3)_ 155 (68) 175(79) 14(53.0) 10.2(0.71) 16 x 16 (4.9x4.9) 155(68) 175(79) 16(60.6) 13.3(0.92) 16x 18(4.9x5.5) 155(68) 175(79) 18(68.1) 16.8(1.16) 18x 18(5.5x5.5) 155(68) 175(79) 19 (72.0) 18.7(1.29) 16 x 20 (4.94. 1) 155(68) 175(79) 23(87.1) 27.4(1.89) 12x 12(3.6x3.6) 6 -12 (152-305) 155(68) 175(79) 14(53.0) 10.2(0.71) 1 27.4(1.89) 14 x 14 (4.3x4.3) 155(68) 175(79) 16(60.6) 13.3(0.92) 16 x 16 (4.9x4.9) 155(68) 175(79) 17(64.4) 15.0(1.04) 16 x 18 (4.9x5.5) 155 6B 175(79) 20(75.7) 20.7(1.43) 16 x 20 (4.9x6. 1) 155 6B) 175(79) 23(87.1) 5. Escutcheon, F2. Data: Type AcINshnent Face of Fitting I I to wall lin I ch (mm) th (nm) I F2 X (13) I-%(4.7-17.4)I Technical Data: Fl Res 58 HSW & HSW/F2 Thread Sprinkler Temp. Max. Max. Ambient K Sprinkler Size Rating Pressure Teiip. Factor Length PSI (bar) Inch(m) ___ OF -C ½NPT (R½) 155 175 I 68 I 79 175 (12) 100 150 I 38 66 5.8 2.45(62) Max. Sprinkler ft(m) C&ing -to. Inch (mm) Deflector Spacing Idendlication SpnlniderTemp. Rating -F (-C) r... gpm(Lpm) psi (bar) Sprinkler Mamber(S1N) 12 x 12(3.6x3.6) (14 -6 01-152) 155(68) 175(79) 16(60.6) 7.6(0.53) R3533 14 x 14 (4.3x4.3) 155(68) 175(79) 18(68.2) 9.7 (0.67) 16x 16(4.9x4.9) 155(68) 175(79) 21(79.5) 13.2 (0.91) 16x 18(4.9x5) 155(68) 175(79) 25 (94.7) 18.6 (1.28) 16 k 20 (4.9x6.) 155(68) 175(79) 29(109.8) 25(1.73) 12x 12(3.6x3)_ 6-12 (152-305) 155(68) 175(79) 22 (83.3) 14.4(l.0) ____- 14x 14(4.3x4.3) 155(68) 175(79) 22(83.3) 14.4(1.0) 16 x 16 (4.9x4) 155 (68) 175(79) 26(98.4) 20.1 (1.39) 16x18(4.9x55) 155(68) 175(79) 31(117.4) 28.6(1.97) Model Fl HS 44 4t0 12 (IOt.Wmin To I I/4(5I.7mmJl#o4wmT 'll FLA'f r. Fec. A' FIk mw' r fl%ff410 AAIUST sTo Wff 4GAll6T *t.L rx ?,R,dgr-7 _IT I 5/I6 f6&n1 AL (84.oJ ViL rim CIXIAR smi. IW107 - (MM-1 Fl RES 44 SWC Fig. 5 Technical Data: Fl Res 44 SWC nuai Sprinkler TemP. Cover Temp. Rating Max. Pressure Max. Ambient Temp. K Sprinkler Length size Rating ___ ______ psi (bar)_____ Factor Inch (mm) -r °F I °C OF 0 ½" NPT 155 68 135 57 175(12) 100 38 4.4 2.45(62) (R M2) Max. Spdnlder Spacing ft(m) ceding -to- Deflector Row gpm(Lpm) Inch (mm) Pressure psi (bar) 5- Identilication Number(SIN) 12 x 12 (3.6x3.6) 4-6 (101-152) 13(49.2) 8.7(0.60) R3531 20.7(1.43) 14 x 14 (4.3x4.3) 14(53.0) 10.2(0.71) 16 x 16 (4.9x4.9) 17(64.3) 15.0(1.1) 16x 18(4.9x5.5) 19 (71.8) 18.7(l.13) 16x20(4.94.1) 23(87.1) 27.4(1.89) 12 x 12(3.6x3.6) 6-12 (152-305) 14(52.9) 10.2(0.71) x 14(4.3x4.3) -14 15 (56.7) 11.7 (0.81) 16x16J4.9x4.9) Q 16.8(1.16) 16 x 18 (4.9x5.5) 20(75.6) 7. ad Sprinkler Temp. Max. Max. Ambient K Sprinkler te Rabnq Pressure Temp. Factor Length psi(bar) Irn) OFIOC 0F 1 0C WI /4 155168 175 I 175(12) 100138 150 I 4.0 2.45(62) J7 Y, Adjustmentace Inch F F,tl of I to wan (mm) Inch (mm) I (13) _____ X6X6(4.7-17.4)l Model Fl Res 40 Recessed Model Fl Res 40 HSW HSW/F2 135FG05 F2 escutcheon, ," (1 3mi adjustment WALL DIMENSM 2 114- HOLE DIA .1. DEFLECTOR I DAJrNSfON I 151;6- OK I f49.2mmJ 227/32Oh& 172.2-1 TURN COLLAR U"M rIGHT AG4INST SPRINKLER *WNCH BOSS. L —1 I/2 (Is..,m] ADILISTUENT Fl RES 58. 44 & 40 HSW/F2 Fig.6 Fig.7 Technical Data: Fl Res 40 HSW & HSW/F2 Escutcheon. F2. Data: I Max. Sprinkler Sprinkler Temp Flow Pressure Sprinkler Spacing ft(m) Deflector Rating °F (°C) gpm (Lpm) P51 klendlication Number (SIN) Inch (m) _.2j2 (3.6x3.6) 155(68) 175 (79) 13(49.0) 10.6(0.7 155j8 175 (79) 16(60.5) 10[11 14x14 (4.3x4.3) x 16(4.9x4.9) --16 155 (68) ______ 17(64.3) 18.1(1.). 1x_16(4.9x4.9) 4-6 (101-152) 20.2(1.39) 175(79) 18(68.1) !.. 18 (4.96.5) 155(68) 175(79) 20(75.7) 25.0(1.72) P3538 - 18x18 (5.56.5) 155(68) 175(79) 22(83.3) 30.2(2.08) 16 x 20 (4.9x6.1) 155(68) 175(79) 23(87.0) 33.1 (2.28) 12x12 (3.6x3.6) 1 155(68) 175(79) 13(49.0) 16L0. 14x14 (4.3x4.3) 6-12 (152-305) 155 (6 8) 175(79) 17(64.3) 18.1 (1.24) 16x16(4.9x4.9) _____ 158) 175(79) 20(75.7) 25.0(1.72) Finishe&1 Standard Finishes Sprinkler Fl, F2, FP Escutcheons Bronze Brass Chrome Plated Bright Chrome Plated White Polyester Coated White Painted Special Applcation Finishes Sprinkler Fl, F2, Escutcheons Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome " Other finishes and colors are available on special order. Consult factory for details. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Maintenance Model Fl Res 49, Fl Res 58, Fl Res 44 and Fl Res 40 Sprinklers should be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model FIRES 49 Residential Sprinkler Specifications Model Fl Res 49 Pendent Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/1t2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/121 [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 m glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 49, SIN R3516 (Bulletin 135). Model Fl Res 49 Recessed Pendent/F1, Model Fl Res 49 Recessed Pendent/F2, Model Fl Res 49 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpffM over the listed coverage area Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.9(70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2 adjustment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 49 Recessed PendentlFl] [Model Fl Res 49 Recessed PendentlF2] [Model Fl Res 49 Recessed PendentlFP] SIN R3516 (Bulletin 135). 91 Model Fl Res 49 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpmlft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/121 [8/121, the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate temperature rating shall be 135°F (570C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: (White] [Custom Color- specify]. J. Concealed pendent sprinklers shall be Reliable Model Fl Res 49 CCP, SIN R3516 (Bulletin 135). Model Fl RES 40 and Fl Res 44 Horizontal Sidewall Residential Sprinkler Specifications Model Fl Res 40 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineere,çl to provide a minimum design density of 0.05 gpm/ftc over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2 NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (681C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.0 (57.1). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 40, SIN R3538 (Bulletin 135). Model Fl Res 40 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 40 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model 172). Standard finish shall be [brass][bnght chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 40/F2, SIN R3538 (Bulletin 135). Model Fl Res 44 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)J low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2 NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 4.4 (62.8). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, SIN R3531 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with 1/2 adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by ® The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices Recycled Rellwabll!(9114) 668-3470 Corporate Offices Revision lines indicate updated or new data. (800) 848.6051 Sales Fax Paper www.re1loblesprinlder.cn Internet Address EG. Printed in U.S.A. 8/04 P/N 9999970235 Upright Pendent Vertical Sidewall Conventional Bulletin 136 Rev.O Model Fl FR Model FIFR Recessed ReIlable Quick Response 0) CD Sprinklers 0 Model Fl FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters' Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council (LPC, UK) NYC BS&A No. 587-75-SA Meets MIL-S-901C and MIL-STD 167-1 Verband der Schadenversicherer (VdS, Germany) NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNlV Patents: US Patent No. 6,374,920 Applies to Model Fl FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1FR and F1FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models Fl FR and Fl FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Horizontal Sidewall Recessed Pendent HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 2 7/4' HOLE CM f57.2,n) I 75/I5'0L4 (49.2.,j -- TURN COLLAR UAT SLER NTt GHT lI 7REACH ROSS ADJUST NT FACE Of F, CftING Dl 2 5/8 01A. [66.7mm3 IOLF IN CEILING 2 5/76 DIA. [58.7mm] cup S. r' x I/2•• ,?ccv. CEILING Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench flt StkIor Type K Factor Sprinkler Height Approval Organization Spunkier Identification Number (SIN) US Metric SSU i Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to indicate Position )" (15mm) Standard Orifice with )" NPT (R/2) Thread 5.6 80 22(56mm) 12,3,4,5,6,7 R3625(l) R3615 '54," (20mm) Large Orifice with /? NPT (R34)Thread 8.0 115 2.3" (58mm) 1,2,34,7,8 113622t11 R3612 (17mm) Small Orifice with )" NPT (R.')Thread 4.2 60 22(56mm) 128 R3623t11 R3613 3" (10mm) Small Orifice with)ç'NPT(R))Thread 2.8 40 2.2'(56mm) 1,2,8 R3621(l) R3611 10mm Orifice XLH with R%" Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conveni nal-Install in Upright or Pendent Position 10mm Orifice XLH with RX Thread 4.2 60 56mm - R3674 15mm Standard Orifice with ) NPT (RX) Thread 5.6 80 56mm 4,6,7 R3675 20mm Large Orifice with 3W NPT 1R34Thrp1 8.0 115 58mm 4,7 R3672 Upright Pendent Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval(') Organizations Sprinkler identification Number (SIN) US Metric ;.' (15mm) .; NPT 5.6 80 22(56mm) 1,23,45,7,8 R3615 %"(20mm) " NPT (R34) 8.0 115 2.3(58mm) 1,2,3.8 R3612 (11 mm) ;ç NPT (R½) 1 4.2 60 2.2"(56mm) 1,2,8 R3613 t" (10mm) ?"NPT (R½) 2.8 40 2.2- (56mm) 12,8 R3611 10mm R3 4.2 60 56mm 4,7 R3614 Refer to escutcheon data table for approvals and dimensions. I Polyester coated upright UL and ULC listed corrosion resistant. .1 2 27/32 CM I IJ61GOI_t (I) REFER TO Fl & F2 ESCUTCHEON DATA TARE FOR APPROVALS AND OIMENSION$ F.AC Jr TO FaCE OF 1.7E4 Nc DIMENSION ADJUSTMENT - I; .'5'1&4 (7) REFER TO FP ESCUTCHEON CIA T4 TABLE FOR APPROVALS AND DIMENSIONS. 2. Vertical Sidewall Model FIFR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) US Metric 1/2 NPT (R½) 5.6 I 80 2.2" (56mm) 1,2 ,3,6,8 15mm ½" NPT (R'/2) 5.6 80 2.2" (56mm) 4 R3685 (1) LPC Approval is for Pendent position only. Orientation Deflector to Ceiling I Dimension (Mm. - Max.) Upright 4" - 12" (102mm - 305mm) Pendent I 6"- 12" (152mm - 305mm) I US Patent No. 6,374,920 Model FIFR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler Nominal Thread Sprinkler Identification Number (SIN) I Light Ordinary Orifice Size US I Metric Length Hazard Hazard )" (15mm) )" NPT(R'h) 5.6 80 1 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with Fl or F2 recessed escutcheon. 156,W-2 ;-'CE OF FITTING TO WALL DIMENSION I 1/4' MIN. I [31.3mmj 2 1,4 HOLE 0/A. C-6 [57 2rnmJ [IOI.6mm-I52.4rnrn] CEILING TO I x 1/2 REDUCER ___7 DEFLECTOR I ' / 'S.''6 OIA.4/jJ 1492mm] . 2 27,'32 0/A. I , -' [72.2mm] 91 rljpJ COLLAR UNTIL -- - -'GtC AGAINST SPR/NNLER WRENCH BOSS. —I - .4DJU5TMENT (I) REFER TO ESCUTHCEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Horizontal Sidewall 3. Installation Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprin- klers and standard response sprinklers should not be inter- mixed. The Model Fl FR Recessed Quick Response Sprinklers are to be installed as shown. The Modal Fl or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model Fl FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all wananties. When installing Model F1FR Sprinklers, use the Model D 5pm- kier Wrench. When installing Model F1FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTEC11ON AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. IOF Bulb Color °c Ordinary 57 1 135 10)1F(38C) Orange Ordinary 68 I 155 100°F(38C) Red Intermediate 79 I 175 150°F(66C) Yellow Intermediate 93 I 20) 150°F(66°C) Green High (1) 141 225°F(107°C) Blue Not available for recessed sprinklers. Escutcheon Data V. Face of Filling Model MxovWs MAMnent Dimension b Ceiling or Wall Dimension 1/,' Fl 1.2,4,8 Max Recess (38.1mm) 16" 6 Min Recess ' (5mm - 24mm) (19.1 mm) 1/2 " F2 12,3,4,57,8 Max Recess (38.1mm) 3/s" - Min Recess 16 (5mm- 17mm) (24mm) FP 12 Max Recessed / " 6 1,"(38.1mm) Push-or/ (11 mm) 1,2 Min Recessed " " 1" (25.4mm) (2 15/ 4mm) Thread-off No Dimensional Figure for FP Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes "I "I Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coatedt41 White Painted (3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome (I) Other finishes and colors are available on special order. Consult the factory for details. FM Approvals is limited to bronze and brass, chrome or black plated finishes only. FP Push-on/Thread-off escutcheon. UL and ULC listed corrosion resistance. SIN numbers: R3621, R3622, R3623, R3625. Note: For r2" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 014. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by 'e.iab The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices (800)848-6051 Sales Fax (914)829-2042 Corporate Offices www.reliablesprinklw.com Internet Address ®Recycled Paper Revision lines indicate updated or new data EG. Printed in U.S.A. 3107 P/N9999970027 Upright Pendent Vertical Sidewall Conventional L\ Bulletin 117 Rev.S HeIiabk The Designer® Model Fl Sprinkler Standard Upright Standard Pendent Extended Coverage Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW1 Deflector The Designer®ll Model Fl Recessed Sprinkler Recessed Pendent Recessed Extended Coverage Pendent Approval Organizations Underwriters Laboratories Inc. Underwriters Laboratories of Canada Factory Mutual Research Corp. Loss Prevention Council NYC BS&A No. 587-75-SA Pleniere Assemblee Verband der Schadenversicherer NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open (VNlV) Patents: U.S. Patent No. 6,374,92 Applies to Model Fl Vertical Sidewall Sprinklers. Product Description The Fl Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceiling, it is functional and attractive. The Horizontal and Vertical Sidewall Sprinklers provide an equally attractive appearance when ceiling piping cannot be used. Beautifully versatile is the description for the Reliable Model Fl Recessed Designer glass bulb sprinkler. Recessing The Designer® enhances its already low profile decorative appearance, and facilitates a rapid and perfect installation. Model Fl Recessed Designer's escutcheon is highly adjustable. The two piece construction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus facilitating maintenance of above ceiling services. The Designer® Automatic Sprinkler utilizes a frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside of a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. Model Fl Model Fl Recessed Standard Response Sprinklers Horizontal Sidewall Recessed Pendent Extended Coverage Recessed Extended Pendent Coverage Pendent At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The Fl Sprinkler temperature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York, 10523 Model Fl Upright, Pendent & Conventional Sprinklers Installation Wrench: Model 0 Sprinkler Wrench IL r' '' Pendent Conventional Installation Data: Nominal Thread Si I Nominal K Factor Sprinkler Approval Sprinkler Identification Numbers (SIN) Orifice US —'—---1 Height Metric [ Organization Uptight Pendent Standard-Upright (SSU) and pendent Deflectors Marked to Indicate Position 5.6 80 1,23,4,5,6.7 R1725t4 R1715 (15mm) (56mm) 3 L_.1, R172 R1712 17/32' WNIPT 8.0 __ 2.2' (56mm) (15mm)° WNPT (RI/2) . 5.6 80 17/32' (20mmf3 - -YV N P T (R3/4) 8.0 2.3*7 - (58mm) 54 I 1.2,8 1.2.8 R1723'4 R1721 R1713 R1711 (A 4.2 60 (11 min) (10mm) 2.8 40 10mmXLH R3/8 4.2 . 60 - -56.1mm 4,6.7 R1724 R1714 -. -- --- 56.1mm 1OmmXLH R3/8p4.2 60 R1774 15mm 5.6 80 56.1min 58.1min 4.6.7 4.7 R1775 R1772 20mm 8.0 115 LPC Approval up to 286°F (141°C) FM Approval for SSU up to and including 200°F (93°C) only. (F1S5) VdS Approval for Intermediate Response 155°F (68°C) only. Polycoated upright UL and ULC listed corrosion resistant. 2. Recessed Pendent Model Fl Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench —2 /4 HOLE OH.— (5Z2mmJ 15/Id" OH. - K 1/2'" R(OLC(R TURN COLLAR [24mm K 12.7—J UNOL UGH7 AGNT SPRINKLER WRENCH BOSS fl II f' 3/4AWL&MENT 03 a [23.8mm) flg.mmj I Ill L1hJ III Ill III I ll\ Ir77777z Yl777/J I55tGOJA 227132 OH. I I 7TGOM (722mm) (1) When installed directly into a tee, the escutcheon dimensions adjustment will be reduced. Installation Data: Nominal Thread S• re Nominal K Factor Sprinkler g Approval Sprinkler Identification US - Metric Orifice Organization Numbers (SIN) -(15mm) 5.6 80 (56mm) 1.2.3,4,5.7 R1715 - 17/32" (20mm) WNPT (R3/4) . 80 ,, 23" (58mm) 1.2.3.4,8 R1712 W WNPT 2.2" (15mm)" (R1/2) 5.6 80 (56mm) 17/32" (20mm)'1 3/4 NPT (R3/4) 8.0 lii 23" (58mm) 7/16" (11 Mtn) WNPT (R1/2) 42 . 2.2" (56mm) 128 R1713 (10mm) WNPT (RI/2) . 28 40 2.2'" (56mm) 128 81711 L. 10mm R3/8 4.2 60 56.1mm 4,7 R1714 (2) FM Approval Light Hazard - No Limitations Ordinary Hazard - Groups 1 & 2, Wet Systems only. LPC Approval is for 57°C through 93°C ratings. VdS Approval for Intermediate Response 155F (68°C) only. 3. VI 1.11101 IUWVMI Horizontal Sidewall Model Fl Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) I Upht 4"(10 m) - 12" (305mm) I Pendent - 4 (102mm) - 12 (305mm) Installation Data: Nominal Orifice Thread Size Nominal K Factor Sprinkler Height I Organizations Sprinkler Identification Numbers (SIN) US Mc 11ba.(15mm)r W NPT(R1/2)T 56 1 8.0 t22(S6lrnrn) - 1,2,3,4,6,8 R1785 (1) LPC Approval is pendent only, 57°C through 141°C ratings. Model Fl Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench 05 ''r- :111 L L I ' - ;.JR'. .?LL,4R UNTIL TV-I; 4G.IJN5T SPRINKLER NVij;5' NOS —1 j.4(19,ssj ADJUSTMENt Installation Data: Nominal K Factor I Approval Organizations Sprinkler Orifice Thread Size [IuS[Metric Height - Light Hazard Ordinary Identification Hazard [Numbers (SIN) - W (15mm) NPT 5.6 80 2.63(67mm) 1,2,3.5 1,2.5 R1735 Note: UL and ULC Listing permits use with Fl escutcheons, light hazard only. 4. Extended Coverage Pendent Model Fl Extended Coverage Pendent Sprinkler Deflector: EC Pendent Installation Wrench: Model 0 Sprinkler Wrench Approval Type: Extended Coverage - Light Hazard Occupancy Coverage Area Pressure Flow Rate Width x Length Max. Area Nominal K=8.0 (115) K=5.6(80) gpm I Limin psi bar bar ft. x ft. I mx m 26 I 98.4 10.6 0,7 ps it3.5 I 21.6 1.5 16x 16 4.9x4.9 33 I 125.0 I 151.4 .:: 17.0 I 1.2 I 34.7 2,4 18 x 18 5.5 x 5.5 40 25,0 1,7 51.0 20x20 6.0x6.0 Installation Data: Nominal Thread -Nomina K Factor Sprinkler 1 Approval _IPff Rating Sprinkler Metric_- Orifice Size__- US - Height Identification Organizations Numbers (SIN) (20) NPT_L 22(56m 83555 568 - W(l5mm) 5.6 80 2.2(56mm) 1,2,8 L 135,155 57,68 P1745 Model Fl Recessed Extended Coverage Pendent Sprinkler Deflector: EC Pendent Installation Wrench: Model GFR1 Sprinkler Wrench Approval Type: Extended Coverage - Light Hazard Occupancy 2 2132• Oi& Extended Coverage Recessed (1) When installed directly into a tee, the escutcheon dimensions adjustment will be reduced. Coverage Area Pressure Max. Area Flow Rate -- -- ' Nominal Width xLength K=8.0 (115) K=5.6 (80) ____________________ _gpJ_Lknl!! I.._L bar 0.7 _LY!L. 21.6 L_ 1.5 ft X 16x 16 4.9x4.9 26 98.4 10.6 33 125.0 170 1,2 1 34.7 2.4 18 x 1 5.5 x 5.5 40 151.4 25.0 1,7 51.0 3,5 20x20 6.0x6.0 Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Rating Sprinkler Orifice Size US Metric Height Organizations Identification Numbers (SIN) 17132 (20mm)- WNPT 8.0 115 LL_. 2.7(56mm) 1,2,8 135.155 57.68 P1742 Ile (l5mm) W NPT (P112)t5.6 80 22(56mm) 1,2.8 - --;-;-- -57.68 R1745 5. r Model Fl & Fl Recessed Sprinklers Application Model Fl and Fl Recessed sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Installation Model Fl sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model Fl Recessed Sprinklers are to be installed with a maximum recess of 3% inch (19mm). The Model Fl Escutcheon illustrated is the only recessed escutcheon to be used with the Model Fl Pendent and EC Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl Recessed Pendent and EC Pendent Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange covers to protect the bulb during the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Maintenance The Models Fl and Fl Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Finish (where applicable) Temperature Ratings Classification Sprinkler Temperature Maximum Ambient Temperature Bulb Color °C IF °C IF Ordinary 135 57 100 38 Orange Ordinary 155 68 100 38 Red Intermediate 175 79 150 66 Yellow Intermediate 200 93 150 66 Green Hight 286 141 225 107 Blue Extra High" 360 182 300 149 Mauve (1) Not Available for Fl Recessed Patents: U.S. Patent No. 6,374,920 Applies to Model Fl Vertical Sidewall Sprinklers. Finishes(l) Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome White Polyester Coatedt30 White Painted - Special Application Finishes Sprinkler Escutcheon Bright BraSS121 Bright Brass Black Plated Black Plated Black Paint 3 Black Paint Off White13' Off White Satin Chrome Satin Chrome Lead Plated IM41 Wax Coated(314 ) Wax _Over _Lead '354 Other colors and finishes are available on special order. Consult factory for details. 200°F (93°C) maximum. UL and tJLC listed, and NYC approved only. (4)155°F to 200°F (68°C to 93°C) ratings only. 286°F (14 1°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). UL and ULC listed corrosion resistant SIN numbers: R1721, R1722, R1723 and R1725. Note: For V orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 013. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by le eml2ab The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Recycled Paper Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address E.G. Printed in U.S.A. 37 PIN 9999970011 '/1 A5b96o`)Yi 214 Dec-122008 11:44 AM CityofCdrlsbad Fire Prevention 602-8561 Automatic Sprinkler Systems FORM 2-I Contractor's Material and Test Certificate for Aboveground Piping (te I2. Ii Property Name t'ic*3&4 çtI jIIL AN04PA. __j Procedure Upøn completion of work, Inspection and tests shall be made by the contractor's representative and witnessed by n owner's representative. All defects shall be corrected and the system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and 5i9ned by both r presentathres. Copies shall be prepared fur approving authori- ties, owners, end contractors. it Is understood that the owner's representative's signature In no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Plans Accepted by (approving authority's name(s)) IZE Address installation conforms to accepted plans? D No Equipment used is approved? ('s No If no, explain deviations. Instructions Has person In charge of tire equipment been instructed as to location of control valves and care and maintenance of this new equipment? EVy'es 0 No If no, explain. Have copies of appropriate Instructions and care and maintenance charts and NFPA 13 been left on premises? 0 No If no, explain. Location of System Supplies building(s) -. Al 4'4(J4tt -. Spriiilcler Year of Orifice Temperature Make Model Manufacture Size quantity Rating AG F1 ER-1a II -. LFI f .44 1 _i. i- _ - Pip : standard. . El No Fittings conform to f LrP4 standard. 0 No If no, explain. PACE laf 3 Copyright 0 2000 National Fire Protection Association 414 Dec-122008 11:44 MI CityofCarlsbad Fire Prevention 602•8551 Automatic Sprinkler Systeths FORM 2qVU Contiactor's Material and Test Certificate for AbovegrOund Piping cont Test Description (cent.) PNUMA71Q Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 11/2 psi (0.1 bar) in 24 hours, Test pressure tai,ks at normal water level and air pressure and measure air pressure drop, which shall ,not exceed 11/2 psi (0.1 bar) In 24 hours. Tests All piping hydrostatically tested at ., psi (bar) for __.hrs. Dry piping priouhiatically tested? 0 Yes 0 No Equipment operates pmpaily2 ø"Ves C] No F no, state reason. Drain test—Reading of geugetocated near water supply test pipe: Static pressure: ') 3 psi (bar) Drain tast—.ReslduaF pressure with valve In test pipe open Wide: io_ psi (ear) Underground mains and iead*in connections to P/sWn risers flushed bere connections made to sprinkler piping Verified by copy of the U Form No. 95B Yes C] No 0 Other Flushed by Installer of undirground sprinider piping eyes LI No 0 Other If other, explain. 1ank Testing Gaskets /qf4 Number used _______ Locations ... Number removed Welding A11A -- Welded piping? C] Yes 0 No if yes, Do you certify as the sprinkler contractor that welding procedures comply with the requirements of at least AWS Dl 0.9, Level AR4? C] Yes Li No Do you certify that the welding was perft,nned by welders qualified in corn- pliañce with the requlrernQnts of at least AWS Dl 0.9, Level AR.37 0 Yes 0 No Do you certify that welding was carded out In compliance with a documented quality control procedure to insure that all discs are retrieved, that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? 0 YeS 0 No Hydraulic Data Nameplate Nameplate provIded? EYes 0 No If no, explain. Remarks Date left in service with all control valves open: Sprinkler Contractor ii/_V'77k_ /t7 7Qi/JN'( Signatures of Test Witnesses For property owner (signed) .. TitleipL FW Date_______ For sprinklCr contractor (sigrfd) .._- Title Date PACE 33 Copyright lb 2000 National Fire Protection Associ@tlon 3/4 Dec•122008 11:44 /VI CityofCarlsbad Fire Prevention 602-8561 Automatic Sprinider Systems FORM 2.1 Contractor's Material and Test Certificate for Aboveground Piping cont,) Alarm Valve-or Plow Indicator - - Alarm Device . -- - Maximum Time to. op Through Thst Pipe Type. Make Model Min. Sec. lic!t&t WiTL 4k ii__-I -°- — Dry Pipe Operating Test i/ A -. Dry Valve Make Model .SerlalNo. Make Model SeilalNo. [ Inme to Trip Through Water Air Thp Point - Air Time Water Reached Alarm Operated Test Pipe" Pressure Pressure Pressure Test Outlet* Properly MIn. See, Psi (Bar) - (Bar) Psi (Bar) — Mm, Sec. - Yes No Without . . 0.0.0. With Q.O.D. If no, explain. Deluge and PreaciSon Valves /'y Z!, Operation 0 PneumatIc 'Electric 0 Hydraulic Piping supervised? 0 Yes 0 No Detecting media supervised? 0 Yes 0 No Is there an accessible fac ll' in each druit for testing? . 0 yes 0 No If no, explain, Does each cinult operate Does each circuit Maximum Time to supervision loss alarm? operate uaive release? Operate Release Yes - No Yes No Mike Model Mlii. Sec. Test Description HI"DROSTATIO Hydrostatic tests shall be made at not less than ?00 psi (13.5 bar) for two hours or 50 psi (3.4 bar) above static pressure In excess of 150 psi (10.2 bar) for two hours. Differential dry pipe valve clappers shell be left open during test to prevent damage, All aboveground piping leakage shail 'be stopped. FLU.rl-IING: Flow the required rate until water Is clear as Indicated by no collection of foreign material in burlap bags at outlets such as hydrants aôd blow-offs. Flush at flows not less than 400 gpm (1514 L/miri) for 44n. (102.-mm) pipe, 600 gpm (2271 Llnnln) for 5-in. (127-mm) pipe, 750 gpm (2839 1/mm) for 6-in. 052-mm) pipe, 1000 gpni (3785 L.(min) for 8-in. (203-mm) pipe, 1500 gpm (5678 1/mm-) for 10-In, (254..mm) pipe arid 2000 gpm (7570 1/mm) fOr 12-in. (305-mm) pipe. When supply cannot produce stipulated flow rates, obtain msxirhum available. 'Measured firn time Inspacr's test pipe Is opened. -- PACE 2 of 3 Copyright 0 2000 National Fire Protection Auoclatlon /4 Sô',oO1E Automatic Sprinkler Systems FORM 2-1 Contractor's Material and Test Certificate for Aboveground Piping 1½ Property Name: 1VI2/4 fI(bLIT1 1116 etY F; Address Procedure Upon completion of work, Inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and the system left in service before contractor's personnel finally leave, the job. . . A certificate shall he filled out and signed by both representatives. Copies shall be prepared for approving authori- ties, owners, and contractors. It is understood that the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. . Plans Accepted by [approving authority's name(s)] U}YL.L'' '1i4\ € Address Installation conforms to accepted plans? ices 0 No Equipment used is approved? . . ties 0 No If no, explain deviations. Instructions . Has person In charge of fire equipment been instructed as to location of control valves AS and care and maintenance of this new equipment? 0 No It no, explain. Have copies of appropriate instructions and care and maintenance charts and NFPA 13 been left on premises? . Yes . 0 No If no, explain. Location of System . Supplies building(s) 4" il141 t Sprinklers Year of Orifice - Temperature Make Model Manufacture Size Quantity Rating J if - 1 F 1 Pipe and Fittings Pipe NP4 I3b conforms to standard. 3-c' 0 No Fittings conform to /Vp —OA 131.t standard. Zes U No If no, explain. PACE 1 of 3 2/4 Copyright 0 2000 National Fire Protection Association FORM 2-J Automatic Sprinkler Systems Contractor's Material and Test Certificate for Aboveground Piping (cont,) Alarm Valve or Flow Indicator Alarm Device Maximum Time to Operate Through Test Pipe Type Make Model Mm. Sec. Dry Pipe Operating Test AJ/A Dry Valve Q.O.D. I Make Model Serial No. Make Model Serial No. Time to Trip Trip Point Time Water Alarm Through Water Air Alt Reached Operated Test Pipe* Pressure Pressure Pressure Test Outlet* Properly Mm. Sec. Psi (Bar) Psi (Bar) Psi (Bar) Mm. Sec. Yes No Without Q.O.D. With Q.O.D. If no, explain. Deluge and Preaction Valves• fl//A Operation U Pneumatic Electric U Hydraulic Piping supervised? 0 Yes 0 No Detecting media supervised? 0 Yes 0 No Is there an accessible facility in each circuit for testing? 0 Yes 0 No If no, explain. Does each circuit operate Does each circuit Maximum Time to supervision loss alarm? operate valve release? Operate Release Yes No Yes No Make Model Mm. Sec. Test Description HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for two hours or 50 psi (3.4 bar) above static pressure In excess of 150 psi (10.2 bar) for two hours. Differential dry pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. FLUSH/NC: flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Flush at flows not less than 400 gpm (1514 L/mln) for 44n. (102-mm) pipe, 600 gpm (22 71 1/mln) for 5-in. (127-mm) pipe, 750 gpm (2839 L/min) for 6-in. (152-mm) pipe, 1000 gpm (3785 L/min) for 8-in. (203-mm) pipe, 1500 gpm (5678 1/mm) for 10-in. (254-mm) pipe and 2000 gpm (7570 1/mm) for 12-in. (305-mm) pipe. When supply cannot produce stipulated flow rates, obtain maximum available. Measured from time inspector's test pipe is opened. PACE 2 of 3 3/4 Copyright © 2000 National Fire Protection Association Automatic Sprinkler Systems FORM 2-1 %Y Contractor's Material and Test '. Certificate for Aboveground Piping (cont.) Test Description (cant.) PNEUMATIC Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 11/2 psi (0.1 bar) In 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1112 PSI (0.1 bar) In 24 hours. Tests All piping hydrostatically tested at ZiV psi (bar) for hrs. Dry piping pneumatically tested? 0 Yes 0 No Equipment operates properly? iic5 0 No If no, state reason. Drain test—Reading of gauge located near water supply test pipe: Static pressure: psi (bar) Drain test—Residuar pressure with valve In test pipe open wide: psi (bar) Underground mains and lead-in connections to system risers flushed b,fore connections made to sprinkler piping Verified by copy of the U Form No. 85B $yes 0 No 0 Other Flushed by installer of underground sprinkler piping Yes 0 No 0 Other If other, explain. Blank Testing Gaskets Number used Locations Number removed Welding Welded piping? 0 Yes If yes, Do you certi' as the sprinkler contractor that welding procedures comply with the requirements of at least AWS D10.9, Level AR-3? 0 Yes 0 No Do you certify that the welding was performed by welders qualified in com- pliance with the requirements of at least AWS D1 0.9, Level AR-3? 0 Yes 0 No Do you certify that welding was carried out In compliance with a documented quality control procedure to insure that all discs are retrieved, that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? 0 Yes 0 No Hydraulic Data Nameplate Nameplate provided? .a'Yes 0 No If no, explain. Remarks Date left in service with all control valves open: 12"A LAO-% INF—I(A CEIKI Sprinkler Contractor: - 0411 V fl'i77'hi1 Signatures of Test Witnesses . For TitIe'j 1 41 property owner (signed). _ I= Date For sprinkler contractor (signed) 4/4 Copyright 0 2000 National Fire Protection Association