Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
7168 AVIARA DR; ; AS130029
City of Carlsbad Sprinkler Permit Permit No: AS130029 Status: APPROVED Permit Type: SPRINK Applied 3/14/2013 Parcel No: 2156110100 Approved: 3/20/2013 Lot #: 0 Reference No.: Issued: 3/20/2013 PC #: • Inspector: Project Title: LEATHER RESIDENCE NEW CONSTRUCTION Applicant: PREMIER FIRE PROTECTION 12651 .RIDGETON DR LAKESIDE, CA 619-390-5047 Owner: LEATHERS DARREN D&CHONNETTE E 1749 SKIMMER CT CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 404 0 404 0 October 31 2008 The Viking Corporation.,210 N.1 rial Park Roa Hastings MI 49058 Telephone 269-946--9.501 Technical Services 877-38475464 Fax 269-94 . 5-4495 Email tochsvcs@vik'ingtorp.com DESCRIPTION Viking Freedom' Residential Concealed Pendent Sprinkler VK457 is a small high sensitivity solder link and lever residential sprinkler designed for installation on con- cealed pipe systems where the appearance of a smooth ceiling is desired The orifice design with a K Factor of 4.9 (70,6 metric*), allows the sprinkler s efficient use of available water supplies for the hydraulically designed fire protection system The fast response operating element and special deflector combine speed of operation and areas of coverage to meet residential sprinkler standards. The sprinkler is pre assembled with a threaded adapter for installation with a 'ow profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover . . ...... . plate The'push-on",thread off design of the concealed cover plate assembly allows - easy installation of the cover plate after the system has been tested and the ceiling finish has been applied while also providing up to 1/2 (12.7 mm) of vertical adjustment The cover assembly can be removed and reinstalled allowing temporary removal of ceiling panels without taking the sprinkler *system out of service or removing the sprinkler. LISTINGS'AND APPROVALS cULus Listed: Category VKKW Refer to the Approval Chart on page 147w and Design Criteria on page 147x for cULus Listing requirements that must be followed. TECHNICAL DATA Specifications: Viking Technical Data may be foundn Available since 2008. Minimum Operating Pressure: Refer to the Approval Chart. The Viking Corporation's Web site at Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically . http:llwww.vikinggroupinc.com. to 500 psi (34.5 bar). . The Web site may include amore recent Thread size: 1/2' (15 mm) NPT . edition of this Technical Data page. Nominal K-Factor: 4.9 U.S. (70.6 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Overall Length (Sprinkler Body): 2-3/16' (56 mm) Material Standards: Sprinkler Body: Brass UNS-C84400. Deflector: Copper UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Seat Assembly: Brass UNS-C31600 Compression Screw: Brass UNS-C36000 Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Form No. F_072607 Replaces-page 147u-z, issued September 5, 2008. (Added square cover 15394.) ,4sl3ooey October 31, 2008 Sprinkler 147w l r%,%R iti r i r t vi- A I The Viking Corporation, Telephone: 269-945-9501 Technical Services 877 lustrial Park Road, Hastings Ml 49058 464 Fax: 269-9454495 Email: techsvcs@vikingcorp.com Sprinkler Base NPT Thread Size Nominal K-Fadtor Maximum Water I Overall Length SIN. (Sprinkler Body) Part, Number' g Pressure Wqrkih Inches mm -U.S. metric' inches mm 14694A VK457 1/2 15 4.9 70.6 175 psi (12 bar) 2-3/16 56 Listings and Approvals3 Maximum Areas of Coverage5 Minimum Water SUpply Requirements5 (Refer also to Design Criteria on page 147x.) cULus4 NYC NSF7 Installed below smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2/12 (9.50). 12 ft. x 12 ft. (3.7 m 3.7 m) 13 gpm @ 7.0-psi (49.2 Umin@ 0.48 bar) AX1 -- AX1 14 ft. x 14 ft. (4:3 mx 4.3 m) 13 gprn©7.0 psi (49.2 L/min© 0.48 bar) AX1 -- AX1 16 ft. xl6 ft. (49mx49m) l3gpm@70 psi (492Umin@048bar) AX1 AX1 l8 ft. xl8 ft. (5.5mx5.5m) 179pm@12.o psi (64.4L/min©O.83bar) AX1 -- AX1 20 ft. x 20 ft. (6.1 m 6.1 m) 20 gpm© 16.7 psi (75.7 Umin © 1.15 bar) AX1 -- AX1 Installed below ceilings with slopes6 up to and including a 8/12 (33.70) pitch. Refer to Figure 5 on page 147z. UL NYC NSF' 16 ft. xl6 ft. (49mx49m) 26gpm@282 psi (984L/miri© 1.94 bar) AX1 AX1 18 ft. x 18 ft. (5.5 m 5.5 m) 31.gpm @40.0 psi (117.3 Umin @2.76 bar) AX1 -- AX1 20 ft. x 20 ft. (6.1 m 6.1 m) 31 gpm @40.0 psi (117.3 L/min @2.76 bar) AX1 -- AX1 Sprinkler Temperature Rating Cover Temperature Rating X - 135 °F (57 °C) cover 137501, 14934' (large diameter), Cover Plate Finishes A - 165 °F (74 °C) or 15394' (square cover plate) 1 - Polished Chrome, Painted White, Painted Ivory and Painted Black' Foothotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum Water Supply Requirement" used. Areas under sloped ceilings must be measured along the ceiling slope. Actual floor coverage in the horizontal plane under sloped ceilings will be less than the listed area of coverage. Tested and Certified by NSF (National Sanitation Foundation) to NSF/ANSI Standard 61, Drinking Water System Components. Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. October 31, 2008 FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone 269-945-!9501 Technical Services Z77'484-5464. Fax 26.9-945-4495 Email tec.hsvcs@vikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Viking Freedoms Residential Concealed Pendent Sprinkler VK457 and Cover Plate Assembly must be ordered separately Sprinkler: Part No. 14694AC (includes a 165 °F (74 °C) rated sprinkler with a protective plastic cap covering the unit). Cover Plate Assembly: Base Part No. 13750 (2-314" diameter), Base Part No. 14934 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/SW1004, Painted Ivory = M4SW1634, Painted Black = M-/SW1007 Temperature Suffix (°F/C): 135°/57 A For example, cover 13750 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13750FA. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Part No. 13623W/B (available since 2006), or Head Cabinet Wrench Part No. 13619*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a '/2" ratchet (not available from Viking). **Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the fusible element to disengage releasing the sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinkler Model VK457 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Ordinary 165 °F(74C) 1 100F(38°C) 135°F(57C) . 13750 14934 15394 Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory, or Painted Black Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL SIDEWALL GLbB PRINKLER CORPORATION DESCRIPTION AND OPERATION QUICK RESPONSE A U TO MA TIC SPRINKLERS GL SERIES UPRIGHT. PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule ex- ceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depend- ing upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. 'Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (79°C), 200°F (93°C), 286°F (141°C) *Water Working Pressure Rating -175 psi (12 Bars) 'Factory tested hydrostatically to 500 psi (34 Bars) 'Maximum low temperature glass bulb rating is -67°F (-55°C) 'Frame - bronze ' Deflector - brass • Screw - brass *Bulb seat - copper • Spring - nickel alloy ' Seal - teflon *Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COI OP (flflIMf CLASSIFICATION I AVAILABLE SPRINKLER I I BULB COLOR I I N.F.P.A. MAXIMUM I I I I TEMPERATURES I i CEILING TEMPERATURE I ORDINARY -'Ji ORANGE/RED I1O0F38?€l INTERMEDIATE F 7i9G934C I YELLOW/GREEN I6°Cl HIGH 286SF 14MG I BLUE 25 1fl72 I I 229. 4O77AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-8464583 9 FAX989-846-9231 MAY 2011 A-20 BULLETIN GL5615, REV. #7 QUICK RESPONSE AUTOMATIC SPRINKLERS. GL SERIES UPRIGHT. PENDENT* VERTICAL SIDEWALL HORIZONTAL SIDEWALL• CONVENTIONAL. (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2 NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) white Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. STYLE SIN K 135°F 155°F 175°F 200°F 286°F cULus F.M.PC CE NYC - DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°CMEA 101-92-E GL2815 2.8 X X X X X X - - - x GL4215 4.2 X X X X X X - - - x UPRIGHT GL5615 5.6 X X X X X X X X X X GL8115 7.8* X X X X X X X - - X GL8118 8.1 X X X X X X X XX x GL2801 2.8 X X X X X X - - - x GL4201 4.2 X X X X X X - - X PENDENT GL5601 5.6 X X X X X X X X X X GL8101 7.8" X X X X X X X - X GL8106 8.1 X X X X X X X X X X VERTICAL GL5632 5.6 X X X X X X X - - - SIDEWALLt GL8133 8.1 X X X X X I X - - -. GL2826 2.8 X X X X X X - - - x HORIZONTAL GL4226 4.2 X X X X X X - - - x SIDEWALL §GL5626 5.6 X X X X X X X - - X GL8127 8.1 X I X I X I X X X - - - - CONVENTIONAL GL 5.6 X X X X X - - X X - (OLD STYLE) GL8125 8.1 X X X X X - - x x - HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 410 12" BELOW THE CEILING, FM APPROVED 4" TO 611. t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. ORDERING INFORMATION SPECIFY Quantity • Model Number • Style Orifice • Thread Sizes . Temperature Finishes desired ° Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.) GL613E FIRE SPRINKLER CORPORATION DECEMBER 2006 PRINTED U.S.A. BULLETIN GL5615, REV. #6 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-390-5047. ADDRESS : P.O. Box 2027, Lakeside CA 92040. LICENSE : 939040 DESIGNER : JOHN MOBLEY DATE : 02-21-2013 FILE : LEATHER JOB NAME : LEATHER RES TWO HEAD CALC 16 X 16 LOCATION : 7168 AVIARA DRIVE DESIGN DATA. DESIGN CRITERION: TWO HEAD CALC 16 X 16 MIN SPR FLOW AREA PER SPRINKLER TOTAL CALCULATED AREA TOTAL SPRINKLERS CALCULATED FLOW DATA. TOTAL SPRINKLER FLOW DOMESTIC DEMAND TOTAL WATER REQUIRED 13 Gpm 256 Sq Ft 512 Sq Ft 2 26.0 Gpm 5.0 Gpm 31.0 Gpm pins h,nc been iv [0%0 1 ! II ureni vmljihdnce 101 he ciiieiic rIiiI1: LOIICS and tan(IaIIis III 115CC r ihe I5 lilt (II elilltr Cliii II1IV Lltlli/C ii)[iiiIl ii iii it,IiCaliOii for ii hiildiii Ii h e ipi cI. at lerstaiidi ni that this icvitn eIii ts the owner or C011iractor or their 'i Ie sinal eiiiiec, or architect r sole rsponsihilit IF I LIII ioutipliance with said codes and standards. ieiudin the 1),111,11 rill code or Ilir any responsihilty for iktic iciicies. errors. OmIssions ot neliglice in these n liether or not noted in this review. IMie.(3 Reviewerc_I 1< I-('(IM v1END APPROVAl. t<i('( )\tNll.NI) APPRoVAl. AS NOTED BASE OF RISER NODE: B FLOW: 31.0 Gpm PRESSURE: 34.0 Psi AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE PHONE HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-390-5047. ADDRESS : P.O. Box 2027, Lakeside CA 92040. Date:' 02-21-2013 File: F:\RESDEN43\LEATHER.RES JOB : LEATHER RES TWO HEAD CALC 16 X 16 SOURCE I STATIC : 59.0 Psi RESIDUAL : 50.0 Psi FLOW : 1200 Gpm DESIGN I SPRINKLER MANUF : VIKING MODEL : VK457 I SPRINKLER Q : 13.0 Gpm VALVE : .0 Psi I SPRINKLER P : 7.0 Psi METER : 6.0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm 1 10.0 ----------------------------------------------------------- 4.9 7.1 13.0 2 10.0 4.9 7.0 13.0 3 10.0 7.3 4 10.0 15.6 5 10.0 24.7 T 10.0 27.5 B .0 34.0 5.0 DOME A .0 36.1 M .0 36.7 S .0 SOURCE 45.3 31.0 Page 1 SPRINKLERS FLOWING AREA PER SPRINKLER TOTAL DESIGN AREA MIN SPRINKLER FLOW REQUIRED DENSITY COMPUTED DENSITY TOTAL SPRINKLER FLOW TOTAL DOMESTIC FLOW TOTAL WATER REQUIRED TOTAL SPRINKLER PRESS WATER METER LOSS VALVE FIXED LOSS SUPPLY PRESS AVAILABLE DEMAND PRESS REQUIRED PRESSURE CUSHION MAXIMUM VELOCITY 2 256 512 13 .051 .051 26.0 5 31.0 39.3 6.0 .0 59.0 45.3 13.7 12.1 Sq Ft Sq Ft Gpm Gpm/Sq Ft Gpm/Sq Ft Gpm Gpm Gpm Psi Psi Psi Copyright (2003) Psi by Psi Hydronics Engineering Psi 34119 Fremont Bi, Suite 609 Fremont, Ca., 94555 F/S (800) 845-9819 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : PREMIER FIRE PROTECTION. (619)-390-5047. ADDRESS : P.O. Box 2027, Lakeside CA 92040. Date:' 02-21-2013 File: F:\RESDEN43\LEATHER.RES JOB : LEATHER RES TWO HEAD CALC 16 X 16 PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 13.0 K= ------------------------------------------------------------------------------- 4.9 L= 4.0 Pt 7.1 Pt 7.1 1 Q= 13.0 F= B F= 5.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 9.0 .0307 Pf .3 Pn 6.9 3 Pt 7.3 2 q= 13.0 K= 4.9 -------------------------------------------------------------------------- L= 5.0 Pt 7.0 Pt 7.0 2 Q= 13.0 F= B F= 5.0 C= 150 Pe .0 Pv -.1 Vel= 4.4 D= 1.101 TL= 10.0 .0306 Pf .3 Pn 6.9 3 Pt 7.3 3 q= .0 K= .0 -------------------------------------------------------------------------- L= 57.0 Pt 7.3 Pt 7.3 3 Q= 26.0 F= BB7R F= 17.0 C= 150 Pe .0 Pv -.5 Vel= 8.8 D= 1.101 TL= 74.0 .1106 Pf 8.2 Pn 6.8 4 Pt 15.6 - q= .0 K= .0 L= 69.0 Pt 15.6 Pt 15.6 4 Q= 26.0 F= B8R F= 13.0 C= 150 Pe .0 Pv -.5 Vel= 8.8 D= 1.101 TL= 82.0 .1106 Pf 9.1 Pn 15.0 5 Pt 24.7 5 q= .0 K= .0 -------------------------------------------------------------------------- L= 10.0 Pt 24.7 Pt 24.7 5 Q= 26.0 F= LLR F= 15.0 C= 150 Pe .0 Pv -.5 Vel= 8.8 D= 1.101 TL= 25.0 .1106 Pf 2.8 Pn 24.2 T Pt 27.5 T q= .0 K= .0 -------------------------------------------------------------------------- L= 10.0 Pt 27.5 Pt 27.5 6 Q= 26.0 F= SCRR F= 10.0 C= 150 Pe 4.3 Pv -.5 Vel= 8.8 D= 1.101 TL= 20.0 .1106 Pf 2.2 Pn 26.9 B Pt 34.0 B q= 5.0 DOME -------------------------------------------------------------------------- L= 5.0 Pt 34.0 Pt 34.0 7 Q= 31.0 F= LLB F= 19.0 C= 150 Pe .0 Pv -.4 Vel= 8.2 D= 1.245 TL= 24.0 .0841 Pf 2.0 Pn 33.6 A Pt 36.1 A q= .0 K= .0 -------------------------------------------------------------------------- L= 70.0 Pt 36.1 Pt 36.1 8 Q= 31.0 F= CCEE F= 18.0 C= 150 Pe .0 Pv -.1 Vel= 3.0 D= 2.067 TL= 88.0 .0071 Pf .6 Pn 36.0 M Pt 36.7 M q= .0 K= .0 -------------------------------------------------------------------------- L= 10.0 Pt 36.7 Pt 36.7 9 Q= 31.0 F= G F= 2.0 C= 150 Pe .0 Pv -1.0 Vel= 12.1 D= 1.025 TL= 12.0 .2169 Pf 2.6 Pn 35.7 S Pt 39.3 Meter = 6.0 Q= 31.0 <<< SOURCE >>> Pt 45.3 E=>45-E1b L=>90-E1b B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : PREMIER FIRE PROTECTION. (619)-390-5047. ADDRESS : P.O. Box 2027, Lakeside CA 92040. DATE : 02-21-2013 FILE : F:\RESDEN43\LEATHER.RES JOB : LEATHER RES TWO HEAD CALC 16 X 16 PSI FIRE SPRINKLER HYDRAULIC GRAPH 100 90 80 70 60 50 40 30 20 10 0 300 450 600 750 0 Supply Curve Static : 59.0 Resid : 50.0 Flow : 1200.0 900 1050 1200 1350 1500 FLOW - Gpm Demand Curve Avi Pr : 59.0 @ 31 Req Pr : 45.3 @ 31 Pr Cush: 13.7 Copyright: Hydronics Engineering, 2003. 34119 Fremont Bl, Suite 609, Fremont, CA. 94555. (800) 845-9819.