HomeMy WebLinkAbout1000 AVIARA PKWY; ; AS060221City of Carlsbad Sprinkler Permit Permit No: AS060221 Job Address: 1000 AVIARA PY Status: ISSUED Permit Type: SPRINK Applied 9/8/2006 Parcel No: 2120407000 Approved: 9/14/2006 Lot #: 0 Reference No.: Issued: 9/14/2006 PC #: Inspector: Project Title: COMERICA FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: PARAMOUNT FIRE SYSTEMS, INC. P.O. BOX 713194 SANTEE,CA 619-562-6247 Owner: KELLY CORPORATE CENTER II C L L C C/O THE ALLEN GROUP 5330 CARROLL CANYON RD #200 SAN DIEGO CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 124 0 124 0 tqct3 /Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TV-FRB - 28,4.2,5.6, and 8.0 K-factor • Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. r Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 112"NPT TY1231 - Pendent 2.8K, 112"NPT TV2131 - Upright 4.21K, 112"NPT TY2231 - Pendent 4.21K, 112"NPT TY3131 - Upright 5.61K, 112"NPT TY3231 - Pendent 5.61K, 1I2"NPT TY4131 - Upright 8.01K, 3/4"NPT TY4231 - Pendent 8.0K, 3I4"NPT Page 1 of 10 APRIL, 2006 TFPI7I Page 2 of 10 TFPI7I ESCUTCHEON 7/16(11,1 mm) STYLE 10 or 20 PLATE SEATING ,** NOMINAL RECESSED SURFACE klm~ MAKE-IN ESCUTCHEON 2-1/4 (57,2 mm) WRENCH FLATS SSP DEFLECTOR * H— 2-7/8" (73,0 mm) DIA. SSU * DEFLECTOR 7/16° (11,1 mm) I NOMINAL I MAKE-IN 1 2-3/16° (55,6 mm) 1/2" NPT** f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE 1/2" MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR T_ 7/16" 6* 2-3/16° gN (OMI1 11,1 mm) AL (55,6 mm) _ 'H_ MAKE-IN 1-1/2" II 3 2-3 WRENC (55,6mm)3 (38,1mm) ________ FLATS SSP DEFLECTOR* 2-7/8° (73,0 mm) DIA. -°°-1 1/2" NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4- Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TV2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT 7/16"(11,1 mm) NOMINAL MAKE-IN 1/2" ** NPT TFPI7I Page 3 of 10 ESCUTCHEON PLATE SEATING SURFACE __ - 2-3!16"6 mm) (55,6 mm) 1 (38, STYLE 100r20 RECESSED SSU* ESCUTCHEON DEFLECTOR A7L 7/16" 1 rWRENCJH Ii\ (11,1 mm) MAKE-IN 2-3/16 NOMINAL I _______ (55,6 mm) FLATS 1/2" NPT SSP DEFLECTOR* I---- 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING ** NOMINAL RECESSED SSU* SURFACE MAKE-IN ESCUTCHEON 2-5/16" NPT DEFLECTOR T_ ______ 1/2" (12,7 mm) (58,7 mm) NOMINAL -14" MAKE-IN 1-9/16" WRENCH (39,7 mm) FLATS (57,2 mm) 3 SSP DEFLECTOR* 2-7/8 (73,0 mm) DIA. 3/4 NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3-Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/ps11/2 (40,3 LPM/bar1/2) K = 4.2 GPM/p5i1/2 (60,5 LPM/barl'2) K = 5.6 GPM/psi1/2 (80,6 LPM/bar112) K = 8.0 GPM/psi1'2 (115,2 LPM/bar112) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ..............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Page 40110 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED i WHITE 1POLYESTER 2.8 1/2" PENDENT (1Y1231) and UPRIGHT (TYII3I) 135F/57C Orange 1,2,3,5 155F/68°C Red 175°F/79°C Yellow 200FI93°C Green 286°F/141C Blue NPT 135F/57°C Orange 1, 2, 5 RECESSED (TY1231)* Figure 5 PENDENT 155F/68°C Red 175F/79°C Yellow 200°F/93°C Green 135°F157°C Orange RECESSED (TY1231) Figure 6 PENDENT 155°F168°C Red 175°F/79°C Yellow 200°F193°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135F/57C Orange 1,2 155°F/68°C Red 175°FI79C Yellow 200°F/93°C Green 286F/141°C Blue 135°F/57C Orange RECESSED (Y2231)* Figure 7 PENDENT 155°F/68*C Red 175°FI79C Yellow 200°F/93°C Green 135°F/57C Orange RECESSED (TY2231) Figure 8 PENDENT 155°F/68*C Red 175°F/79°C Yellow 200°F/93C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page 5 of 10 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME I PLATED I WHITE IPOLYESTER LEAD COATED 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) 135°F157°C Orange 1,2,3,4,5,6,7 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F193°C Green 286°F/141°C Blue NPT 135°F/57°C Orange 1,2,4,5 N/A RECESSED PENDENT (TY3231) Figure 9 155°F/68°C Red 175°F179°C Yellow 200°F193°C Green 135°F/57°C Orange 1,2,3,4, 5 I I I I 1,2,4, 5 I Green N/A RECESSED PENDENT (TY3231) Figure 10 155°F/68°C Red 175°F179°C Yellow 200°F/93°C 8.0 3/4,, PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1,2,3,4,5,6,7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200°F193°C Green 286°F/141°C Blue NPT 135°F/57°C Green 1,2,4, 5 N/A RECESSED PENDENT (TY4231)* Figure 11 155°F/68°C Orange 175°F/79°C Red 200°F193°C Yellow 135°F/57°C Orange 1,2, 3,4, 5 N/A RECESSED PENDENT (Y4231 Figure 12 155°F/68°C Red 175°F179°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2° Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 10 TFPI7I SPRINKLER FINISH K TYPE NATURAL I CHROME I WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (1Y3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2' RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4" RECESSED PENDENT NPT (TY4231) PENDENT (1Y3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (1Y3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY323) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1Y4131) 3/4,, RECESSED PENDENT NPT (TY4231) N/A NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, 0r40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) FACE OF ,_57,2 mm) MOUNTING SPRINKLER PLATE / j- (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6.4 mm) I FITTING 1/8" (3.2 mm) NIIA MOUNTING N V SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13116'(20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4'(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" MOUNTING SURFACE/" td•I CLOSURE SERIES 1-1/4" (31,8mm)1 TYFRB 3/4"(19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Page 7 of 10 2-7/8" DIA. - 1/2±1/8" I (73,0 mm) 1/2"(12,7 mm) r (12.7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) I I SPRINKLER PLATE I I FACE OF mm) MOUNTING I FITTING / 1/8" / (3,2 mm) I MOUNTING / 1 SURFACE I16"(33,3 mm) CLOSURE SERIES TY-FRB 1-1/16"(27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. (73,0 mm) 1/2±1/8" 1/2"(12.7 mm) E (12,7±3,2 mm) 2-1/4" DIA. I 1/4"(6,4 mm) FACE OF (572 mm) I I MOUNTING SPRINKLER I PLATE FITTING I 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TY.FRB 1"(25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random Page 8 of 10 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) - (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF MOUNTING SPRINKLER PLATE FITTING 1/8" MOUNTING t SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TYFRB 3/4"(19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4" (73,0 mm) 314"(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) I FACE OF (57,2 mm) MOUNTING --- I SPRINKLER 1/8" PLATE FITTING __ ______________ (3,2 mm) MOUNTING T SURFACE CLOSURE SERIES 1-5/16" (33,3 mm)f TV-FRB 13/16"(20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT TFPI7I - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) r (12,7±3,2 mm) 2-1/4 DIA. 1/4(6,4 mm) I FACE OF 1572 mm) MOUNTING SPRINKLER PLATE <d I FITTING 1/8" I (3,2 mm) T \ MOUNTING SURFACE SERIES 1-1/4"(31,8 mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 1/2±1/8" (73,0 mm) I 1/2" (12,7 mm) (12,7±3,2 mm) _ 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING I I SPRINKLER PLATE I I FITTINGt- (3,2 1/8 m " m) I t \ t t MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY.FRB 1-1/16"(27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH 135 1 135°F157°C 155 155FI68°C 175 175F/79°C 200 20OF/93°C 286 28&F/141°C RATING * Eastern Hemisphere sales only. MODEUSIN TFPI7I Page 9 of 10 P/N 57-XXX-X-XXX 330 2.8K UPRIGHT (1/2NPT) TY1131 331 2.8K PENDENT (1/2°NPT) TY1231 340 4.21K UPRIGHT (1/2"NPT) TY2131 341 4.21K PENDENT (1/2°NPT) TY2231 370 5.61K UPRIGHT (1/2NPT) TY3131 371 5.61K PENDENT (1/2°NPT) TY3231 390 8.01K UPRIGHT (3/4NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin-ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Page 10 of 10 TFPI7I TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446