Loading...
HomeMy WebLinkAbout3312 AVENIDA SERENA; ; AS070011City of Carlsbad Sprinkler Permit Permit No: AS0700II 3312 AVENIDA Job Address: Status: ISSUED SERENA Permit Type: SPRINK Applied 1/19/2007 Parcel No: 2230320400 Approved: 1/19/2007 Lot #: 0 Reference No.: Issued: 1/19/2007 PC #: Inspector: Project Title: HUNTER'S POINT THREE FIRE SPRINKLER INSPECTIONS-@, $62/EA Applicant: SOUTHLAND FIRE PROTECTION, INC 4733 PT. LOMA AV SAN DIEGO, CA 92107 619-523-1400 Owner: REAL ESTATE COLLATERAL MANAGEMENT CO C/O MORROW DEW LIZ LAYMAN 1903 WRIGHT PL #180 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 186 0 186 0 SEE'PERMIT AS070010 7271 CALLE PLATA HUNTER'S POINT FOR CALCS & PLANS NOTE: APPROVED FIRE SPRINKLER PLANS ARE LOCATED IN 7271 CALLE PLATA/HUNTERS POINT. t2AvNWP AS01c)OH 13-190 INSTALLATION OF SPRINKLER SYSTEMS Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work. inspection and tests shaft be made by the contracto?s representative and witnessed by an owner's representative. All detects shall be corrected and system left In service before contractors personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners and contractor. It Is understood the owner's representative's signature In no way prejudices any deim against contractor for faulty material, poor workmanship, or failure to comply with approving authoritys reqiirementsor local ordinances. Property name Date addresi "UX Cl- Accepted by approving authorities (names) Address Plans Installation conforms to accepted plans Yes CJ No Equipment used Is approved Yes D No If no, explain deviations \ Has person In charge of fire equipment been Instructed as Yes U No to location of control valves and care and maintenance I of this new equipment? If no. explain Instructions Have copies of the following been left on the premises? Yes CJ No System components Instructions' Yes El No. Care and maintenance Instructions Yes 0 No NFPA25 . es 0 No Location of system Supplies buildings Year of Orifice Temperature manufacture lze Qnthv rating lfr' /(Li I IF' S'° Spriniders ---------------- Pipe and fittings Type of pipe (LIC . . Type of fittings . N valve or 'F-.. . ____________ Alarm device I Maximum time .to operate I through test connection. Type Make Model Minutes Seconds indicator Diy valve a: 0. D. Make eLSeñ&no Make Model Serial no. Dry pipe operating test - lime to trip through test cdona Water pressure ,'Jr pressure - J - Trip point 'Nair pressure lime water reached; test otJ.tt2 Alarm operated prnpe Minutesf Seconds psi PSI Mnutes Second. Yes No If no, explain . 'Measured from time Inspector's test connection Is opened 2NFPA 13 only requires the fib-second limitation In specific sections FIGURE 16.1 Contxctor's Material and Test Certificate for Aboveground Piping. 2002 Edition SYSrEMS ACCEPTANCE 13-19 Operation Pneumatic 0 Electric 0 Hydraulics Piping supervised 0 Yes D No I Detecting media supervised 0 Yes 0 No Does valve operate from the manual trip, remote, or both D Yes 0 No control stations? Deluge and valves Is there an accessible facility In each cIrcuit for testing? 1 it no, explain. El Yes El No Does each circuit operate Does each circuit operate Màidmum time to Make Model Supervision loss alarm? valve release? Operate release., Yes No Yes No Minutes Seconds Location Make and Setting Static pressure Residual pressure Flea no Pressure and floor model (flowing) reducing Inlet (psi) Outlet (psi) inlet (psi) OutleUpel) Flow (Wm) ( Hydrostatic: PVd=Wc tests shall be made at not less than 200 pal (13.6 bat) for 2 hours or 50 psI (3.4 bar) Test stati rein excess of 150 psi (10.2 bar) for 2 hours. Differential dryplpe valve clappers shall be left open u ng the test to prevent damage. All aboveground piping leakage ehall be stopped. description Pneumatic: Establish 40 psI (2.7 bar) air pressure and measure drop, which shall not exceed 1½ psi (0.1 bat) In 24 hours. Test pressure tasks at normal water level and air pressure and measure sir pressuredrop, which shall not exceed 1½ pal (0.1 bar) In 24 hours. All piping hydrostatically tested at Qpsi (-_-.. bat) for hours It no, state mason Dry piping pneumatically tested 0 Yes D No Equipment operates properly 0 Yes 0 No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or der i v a t i v e s of sodJurn gilicate, brine, or other corrosivemi checals were not used for testing systems or stopping leaks? Yes C:3 No x rain" Reading of gauge located near water Residual pressure with Ive In test I Tests test Isupplytesiconnection: 70t. psi (_ bar) connection open wide: psi ( - bar) Underground mains and lead-In connections to system risers flushed betore connection m a d e t o , sprinkler piping Verified by copy of the Contractor's Material and ibet 0 Yes 0 No Other Explain Certificate for Underground Piping. Rushed by installer of underground sprinkler pipIng CD Yes • No If powder-driven fasteners are used In concrete. 0 Yes D No If no, explain has representative sample testing been satisfactorily completed? Blank testing gaskets Number used Locations . Number removed Welding piping 0 Yea No lfyes... . Do you certify as the sprinkler contractor that welding procedures comply 0 Yes No with the requirements of at least AWS 82.1? Welding Do you certify that the welding was performed by welders qualified In D Yes 0 No compliance with the requirements of at least AWS 02.1? Do you certify that the welding was carried out In compliance with a 0 Yes 0 No documented quality control procedure to ensure that all discs we retrieved, that openings In piping are smooth, that slag and other welding residue ar removed, and that the internal diameters of piping are not penetrated? Cutouts (discs) o Yes 0 No Do you certify that you have a control feature to ensure that A1144— all cutouts (discs) are retrieved? FIGURE 16.1 Continued 20M Edition 13-192 INSTALLkTIONOF SPRINKLER SYST E M S Hydraulic Nameplate provided If no, explain . data nameplate J,Yes •D No. .• . Date left in service with all control valves open Remarks . ....,. .. . .... Name of sprinkler contractor$' 71,. . Teats witnessed by .• . ,. . •. . Signatures For owner (signed) Title Ate D spnt Title Date Additional explanation notes .............. FIGURE 16.1 Continued .. . . .... I .- ............. . 16.2.1.2 Portions of systems noma1Iy sub j e c t e d to system open sprinklers after the test is com p l e t e d , o r t h e o p e r a t i n g working pressures in excess of 1 5 0 p s i ( 1 0 . 4 b a r ) s h a l l b e elements of automatic sprinklers shall be removed after the tested as described in 16.2.2.1atapressure o f 5.0..psi.(&5bar) test iscomp1eted in excess of system working pressure 162 1 12 The trench shall be backfllled between joints be- 16.2.1.3 Where cold weather will not permit testing with Wa fore tdstmg to prevent thovement of pipe ter, an interim air test shall be permitted to be conducted as 1624 13' Where required for safe} y 1 e a s u r e s p r e s e n t e d by described in 162 8 the hazanis of open ueihes, the pap and joints shall be per- 16.2.1.4 Modifications affecting 20 or fewer sprinklers shall mined to be backfihled provided the installing contractor not require testing in excess of syste m w o r k i n g p r e s s u r e . takes theisponsibil forJocatingaudccorrecdng leakage in 16,2.1.5 Where addition or modification is m a d e t o a n e x i s t - excess of ing system affecting more than 20 sprinklers, the new portion 16.2.1.14. 2rovision3ha1fbe in dekor th proper disposal c' shall be isolated and tested at not less than 200 psi (13.8 bar) water used for thshiiig or test ng. ;y for 2 hours. . 16.2.145* Test Blanks. 16-2.1.6 Modifications that cannot. be isolated, such as relo-cated drops, shall not require testi n g i n e x c e s s o f system work- 16.2.1.16.1 Test blanlcs..shall h6epxiht&l1lugs protruding in ing pressure. such a way as to. clearly in4icate..their presence. 16.2.1.7 Loss shall be determined by a drop in gauge pres- 16.2.1A .2 The te$ b1hk5 sh4l nurbered, and the mr sure or visual leakage stalling contractor shall have a recorcilkeeping method enui- ing their removal after work is completed. 16.2.1.8 The test pressure shall b e r e a d f r o m a g a u g e l o c a t e d .. . . .......... ........•. ....................... at the low elevation point of the system or portion being 1621;1. n.sujectto:hydroatiotestpressus e ' t h t clapf tested per of a differential-type valve shall be held off its seat to pre 16.2.1.9 Additives, corrosive chemicals s u c h as sodium-sili- vent damaging the valve. . .. cate, or derivatives of sodium silic a t e , b r i n e , o r o t h e r c h e n u - 16 2 Dr Pfpe'and Dàuble 1em(s) Air Test. cals shall not be used while hydrostatically testing ysteths .I61e.: j. ..:t alirWthtafic test, an air for stopping . pressure leakage.testat 40..psL 2.8. b a 4 s h a l l . b e Conductediot - 16.2.1.10 Piping between the exterior fire d e p a r t m e n t c o n so nection and the check valve in the fire departme n t i n l e t p i p e of 1½ psi (0.1 bar) "f&*bA244WU*9h*l1 be correctedv shall be hydrostatically tested in -the samema m i e r as-the4sal- ........ 16.2.2.2 Where systems. are mnstaned m sp a c e s that are ca- azice of the tern sys pable of being operated at temperatmsbe1ow 320F air 16.2.1.11 When deluge systems are being hy d r o s t a t i c a l l y pressure leakage tests required in 16.2.2 shall be cqnducted at tested, plugs shall be installed in f i t t i n g s and replaced with the lowest nominal temperature of-the space. 2002 Edition