Loading...
HomeMy WebLinkAbout7180 AVENIDA ENCINAS; ; AS08017012/19/23,12:18 PM AS080170 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS080170 7180 AVENIDA Job Address: Status: ISSUED ENCINAS Permit Type: SPRINK Applied 10/22/2008 Parcel No: 2144301900 Approved: 10/24/2008 Lot #: 0 Reference No.: Issued: 10/24/2008 PC #: Inspector: Project Title: POINSETTIA VILLAGE TI FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: AAA FIRE SPRINKLERS OBERLIN PARTNERS L L C 20942 JAPATUL RD P 0 BOX 2062 ALPINE CA DEL MAR CA 619-445-9898 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 Carlsbad Fire Department FILE Copy Plan Review Requirements Category: SPR1NK , TI Date of Report: 10-28-2008 Reviewed by: ';7W Name: Address: AAA FIRE SPRINKLERS 20942 JAPATUL RD ALPINE CA 91901 Permit #: AS080170 Job Name: POINSETTIA VILLAGE Job Address: 7180 AVENIDA ENC1NAS CBAD St: 105 adequately conduct a review to determine carefully all comments attach t iew and approval. Conditions: review is incomplete. At this time, this office cannot necearvD1ans and/or soecification .wiflrcffãli Cond: C0N0003123 [MET] APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 10/28/2008 By: MS Action: AP Oct 22 08 10:55a RAn Fire Sprinklers 16184454052 p.5 tqC0 /Fire & Building I Products Technical Services: Tel: (800)381-9312/ Fax: (800) 791-5500 Series TY-FRB 2.8,4.2,5.6, and 80 K-factor Upright Pendent and Recessed Pendent Sprinklers Quick Response, Standard Coverage - General Description The Tyco* Series TY-FRB. 2.8, 4.2. 56, and 8.0 K-factor, Uptight and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 m glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (314 inch NPT) Recessed Es- cutcheon with 112 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendant position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12.7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable. are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP7I0 for the INSTALLER WARNINGb that provides cautions with respect to handling and instal- lation of spnnklersystems and com- ponents. Improper handling and in- stallation can ponnanently damage a sprinkler system or its compo- nents and cause The sprinkler to fail to operate ma Are situation or cause it to Opelate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TV-FRB Sprinklers de- scribed herein must be installed and maintained in compliance elth this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards ofany otherauthorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their lire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII31 - Upright 2.81C, 11/2-NPT TY1231 - Pendant 2.8K, II2NPT TY2131 - Upright 4.2K, 112'NPT TY2231 - Pendant 4.2K, II2NPT TY3131 - Upright 5.6K, 1I2"NPT TY3231 - Pendent 5.6K, 112"NPT TV4131 - Upright 8.0K. 314"NPT 1Y4231 - Pendant 8011C, 314-NPT TY4831- Upright 8.0K, 112"NPT TY4931- Pendant 8.011C, 1/2"NPT Page 1 of 10 AUGUST, 2007 TFPI7I ESCUTCHEON 7116 (11.1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE 1/2' MAKE-IN ESCUTCHEON NPT I Ssu* DEFLECTOR 711w (11.1 MM) NOMINAL MAKE-IN 2-311r WRENCH T (55,6 mm) FLATS NIPT SSP DEFLECTOR * 2-718 (73,0 mm) DIA. Oct 22 08 10:55a ARA Fire Sprinklers 16194454052 P.6 Page 2 of 10 TFP171 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1- Frame 3- Sating 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2. Button Assembly 5- Compression 7- Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYI 131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT T_ 2-3/W (55,6 mm) 1 STYLE 10or20 RECESSED SSU* ESCUTCHEON DEFLECTOR 7/16' (11.1 mm) MAKE-IN NOMINAL I 2-3/16 WRENCH (55,6 mm) FLATS -1 1/2' NPT ESCUTCHEON PLATE SEATING SURFACE 7116' (11,1 mm) NOMINAL MAKE-IN NPT I SSP DEFLECTOR * L 2-718 (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2. Button Assembly 5- Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT(TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT Oct 22 08 10:55a AAA Fire Sprinklers 16194454052 p.7 TFPI7I Pa.30f 10 ESCUTCHEON 7/18" (11.1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR t 7111V 5 6* \ ____ (11.1mm) 1 2-3116' _______ NOMINAL 4 (55,6 mm) f JL 1I__ MAKE-IN j 2-3116 2 SSP DEFLECTOR * 1 2-7/81(73.0 mm) D 1 NPT (55,6 mm) I (38,11 mm) WRENCH FLATS PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1-Frame 3.SeaIig 4-Bulb 6-Deflector • Temperature rating is indicated on deflector or adjacent to 2-Sutton Assembly 5- Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (7Y3131) AND PENDENT (1Y3231) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT CROSS SECTION 1 - Frame 3- Sealing 4-Bulb 6- Deflector • Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 COITIpreSSICfl orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES 7Y-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT ESCUTCHEON 1/2"(12.7 mm) PLATE SEATING NOMINAL SURFACE MAKE-IN _ NPT 2-5116* (58.7 mm) 1-9116" (39,7 mm) 1/2' (12,7 mm) NOMINAL L3U MAKE-IN 2-114" WRENCH (57,2 mm) FLATS H SSP DEFLECTOR* - 27/8" (73,0 mm) DIP.. 3/4 NPT PENDENT RECESSED PENDENT UPRIGHT STYLE 30 or 40 RECESSED SSU ESCUTCHEON DEFLECTOR 6* Oct 22 08 10:56a AAA Fire Sprinklers 16194454052 p.8 Pagolof 10 TFPI7I 711r (11,1 mm) NOMINAL SSU * 112 MAKE-IN DEFLECTOR NFT I 2-1I4 FM (57.2mm) RENCHI 216" 1- FLATS(39, I _____ sSp* ri DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating Is indicated on deflector or adjacent to 2- Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (rf4831) AND PENDENT(TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi"2 (40,3 LPM/barl12) K = 4.2 GPMIpsi112 (60,5 LPMIbarl'2) K = 5.6 GPMIpsi112 (80,6 LPMlbarl'2) K = 8.0 GPM/psi"2 (115,2 LPMIbar112) Temperature Ratings Refer to Table A and B Finishes Sprinkler Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel wfreflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g.. UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent Installations. .4- Oct 22 08 10:56a AAA Fire Sprinklers 18194454052 p.9 Pag. 1.110 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAl. BRASS I CHROME PLATED WHflE' 1POLYESTER 2.8 PENDENT (TY1231) and UPRIGHT (TYII3I) 135'F157'C Orange 1,2.3,5 Blue 155FrC Red 175'F179'C Yellow- 200'F/93'C Green 28F114C 112' NPT 135'F157C Orange 1,2,5 RECESSED PENDENT (fl'1231r Figure 6 155'F16&C Red 175F179'C Yellow 200'F193C Green 135'P/57'C Orange RECESSED PENDENT (1Y1231 Figure 1 155'FIG8'C Red 175'FI'79'C Yellow 200'F193'C Green 4.2 ii?' NFl PENDEwr (rffl3l) and UPRIGHT (M131) 135'F157'C Orange 1,2 155F/68C Red 175°F119C Yellow 200'F193'C Green 286'F1141'C Blue 135F/57C Orange RECESSED PENDENT (TY2231) FIgure S 155'F168C Red 175'F179C Yellow 200'F!93'C Green 135F/57C Orange RECESSED PENDENT (r12231r FigureS 155F168'C Red 175'F179'C Yellow ooi:,c I Green NOTES: Listed by Underwriters Laboratories. Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 1. Where Polyester Coated Spnnklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10(1!? NPT) or Style 40(3/4' NPT) 314' Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(112' NPT) or Style 30 (3/4' NPT) 112' Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS