7140 AVENIDA ENCINAS; ; FA080044
City of Carlsbad Fire Alarm Permit Permit No: FA080044 7140 AVENIDA Job Address: ENCINAS Permit Type: FALARM Parcel No: 2144302700 Lot #: 0 Status: ISSUED Applied 7/15/2008 Approved: 7/17/2008 Reference No.: Issued: 7/17/2008 PC #: Inspector: Project Title: RALPH'S MONITORING SYSTEM PLAN CHECK & INSP. Applicant: SECURITY SIGNAL DEVICES, INC 1740 N LEMON ST ANAHEIM CA 714-449-9900 Owner: RALPHS GROCERY CO 1100W ARTESIA BLVD COMPTON CA Fees ($) Add'I Fees ($) • Total ($) • Balance ($) 125 0 • 125 0 "a. Fire Alarm • Access Control Aooô44 SSD Systems Security Signal Devices Intercommunication Systems • Security • CCTV • Data Fire Alarm Submittals FOR MLPHS Store# 175 7140 Avenida Encinas Carlsbad, CA 92011 Submitted by; Stuart Starrs Operations Manager SSD Systems 858-675-8139 11031 Via Frontera Ste. B, Rancho Bernardo, CA 92127 (858) 675-8139 (858) 675-8168 Fax IMAGE VIEW 11 05/01/2005 THU 16,25 FAX 8476648026 I0 03/003 Applicant ID No: 644510-001 Service Center No 1 Expires: 31-MAR-2009 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. Listed Service From: ANAHEIM, CA Alarm Service Comøanv: (644510-001) Service Center: (644510-001) SECURITY SIGNAL DEVICES INC SECURITY SIGNAL DEVICES INC 1740 N LEMON ST 1740 N LEMON ST ANAHEIM CA 92801 ANAHEIM CA 92801 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. - CCN Listing Category BP8505 - 1 CVSG (Burglar Alarm Systems] Mercantile $1545-1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31-MAR-2009 "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" IJ 02000L4. . Farm C$-CC 24-MAR-2008 4ay07, 2008 11:13:16 AM Not to scale, Page 1 of 1 Quant. Component 1 07024 board in atatic-resistant bag 1 Enclosure (P/N: 30897) 1 Lock set with 2 keys (P/N: 24065) 1 Transformer (P/N: 29413) 6 2.21 k0 end-of-line(EOL) resistors (P/N: 25899 or 4998113202) 1 Hardware pack 1 Literature pack Note For the D7024 to be addressable, a 07039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. . ...... Techrucal-Specofuatlons -, Environmental Considerations Temperature (operating): +32F to +120°F (0°C to +49°C) Mechanical Properties Color: Red Dimensions (H x W x D): 20.8 in. x 15 in. x 4.3 in. (52.8cm x38.1 cm 10.9 cm) Material: Cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Outputs NAC: 24VFWR nominal, 4Amaxlmum On-board Relays: Two Form C contacts rated at 5 A, 28 VDC Off-board Relays: Up to two D7035 Octal Relay Modules each provid- ing eight Form C relay outputs; contacts rated at5A, 28 VDC In an addressable system, up to 2007053 Multiplex Input-Output Modules per bus for a total of 40 Power Requirements Current (alarm): 380 mA Current (standby): 200 mA Power (primary) 120 VAC, 1.5 A maximum, 60 Hz Sensor Circuits Current: 44 mA maximum per loop Line resistance: 1500 Voltage: 24 VDC nominal Trademarks Chamber Check9 is registered trademark of Bosch Security Systems, Inc. in the United States. CleanMe' is registered trademark of GE lnterlogix in the United States and/ or other countries. Wheelock' is a trademark of Wheelock, Inc. Gentex' is a trademark of Gentex Corporation. D7024FACP D7024 D7024LC FACP without Enclosure and D7024LC Transformer Accessories KEY-625 Replacement Key KEY-625 Europe, Middi. East, AMcm Bosch Security Systems By. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone,+ 3140 2577284 Fan: +3140 2577 330 .m.a.s.curltyayst.n,n5b0.ch.com www.boschs.curlty.com Amorkson Bosch Security Systems. Inc. 130 Purinton Parkway Fairport, New York, 14450, USA Phorec +1800 2890096 Few +1585 223 9180 s.curlty.sal.5i9us.bosch.com www.boschs.curity.us AulefadOm Bosch Security Systems Pt. Ltd 38C Jalan P.mlmpin Singapore 577180 Phone- 489 6319 3450 Few .65 6319 3499 xpr.securltysystemsr9ho.ch.com www.boschx.curlty.com R.pivasnted by O Bosch Security Systems B.V. 20081 Data subject to change without Colic. F3,1429726831 Cur. cellS. Vi. 22 Nov 2006 D7024 FireAlarm Control Panels The D7024 Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The 07024 FACPs support four on-board initiating zones that can be expanded to eight using the 07034. Each initiating zone supports two-wire and four-wire detectors configurable as Class A, Style D (with 07014) or Class B, Style B loops. Each zone can support up to 20 two-wire detectors, or any number of four-wire detectors depending on available power. Each FACP has a built-in digital fire alarm communicator transmitter (DACT). Enhance the 07024 conventional system features when running version 2.02 or higher firmware by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the D7024 turns the conventional FACP into an addressable FACP. The 07039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 18 to 58 and allows up to 100 system users (an addition of 84 PINs to the base system). Four detector zones (expandable to eight); up to 20 two-wire smoke detectors per zone Built-in DACT Two notification appliance circuits (NACs) on board with an Internal 24 VFWR, 4 A NAC power supply Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module Programmable through front panel interface, remote D7033 Liquid-crystal Display (LCD) Keypads, or remote programming software (RPS) Notification Appliance Circuits (NACs) Two on-board Class B, Style V or Class A, Style Z (with D7015) NACs provide up to 4 A of 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, steady, pulsed, and synchronized output for Wheelock'TM and Gentexl notification appliances. User Interface A viewing port in the keyed control panel enclosure door shows the system status light-emitting diodes (LEDs) and LCD display while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing offnormal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all D7033 LCD Keypads connected to the system. All D7036 LCD Annunciators provide custom text annunciation on a 32-character, backlit, two-line LD display. All system keypads and annunciators have built-in sounders. Back-light intensity and sounder volume are programmable. www.boschsecurity.com Personal identification Numbers (PINs) There are 16 PINs available for accessing system control. Assign each number an authority level to limit access to the system control functions. Note The number of PINs increases to 100 with the addition of a 07039 Multiplex Expansion Module. History Buffer The system stores events in a 99-event history buffer. Note The number of events that can be stored in the history buffer increases to 499 with the addition of a D7039 Multiplex Expansion Module. Central Station Reporting The D7024 FACPs send reports to two telephone numbers with full single, double, and backup reporting. They communicate in BFSK. SIA, Contact ID, Modem lila2. and 4/2 and 3/1 Tone Bursts. Dirty Smoke Detector Monitoring All on-board zones and 07034 zones are continuously monitored for smoke detectors signaling a dirty condition using.the Bosch Chamber Check® feature and CleanMe® protocol. If a detector's smoke chamber is dirty, the detector sends a CleanMe' signal on the two-wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop. or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. Accessories The 07024 enclosure has space for additional accessory modules and two D1218 (18 Ah) batteries or two 0126 (7 AN batteries. Category Product ID Product Description Power Supplies 01218 12 V. 18 Ah battery D7038 Remote NAC power supply Detectors For two-wire detectors, refer to D7022--D7024 Corn- patibilityList Technogràrn ON: 34445) Keypads and 07030X Eight-point LED annunciator Annunciators (eight red) D7030X-S2 Eight-point LED annunciator (two yellow, six red) D7030X-S8 Eight-point LED annunciator (eight yellow) D7032 Eight-zone LED annunciator expander (eight red). 07033 . LCD fire system keypad 07036 LCD annunciator Modules 0132B Smoke detector reversing relay mod- ule D184A Auxiliary local energy interface kit D185 Reversing polarity module 0275 EOL power supervision module 07014 Zone converter module D7015 Class B to Class A NAC converter D7031 Silence reset module 07034 Four-point expander 07035 Octal relay module D7035B Octal relay module in box 07039 Multiplex expansion module D7039R Multiptexexpansion module retrofit kit NAC Devices Refer to 07024 NAC Compatibility List Technogram (PI N: 34950) The following additional products are compatible with the D7024 Addressable FACPs: MZet ficationsand-ApprovaIs, -- Listings and UL UOJZ: Control Units, System (U1864) Approvals: CSFM 7165-1615: 147 Factory Mutual Research Modules NYC/MEA (12-92-E, Vol. 7) Complies with: Hong Kong Fire Services Department (HKFSD) .. -'r---. -- --- 'w--w -* lnstallationfCon ori figurat,Notes . & SI3_ '.. Compatible Products The following products are compatible with the D7024 FACPs: Category Product ID Product Description Pull Stations Batteries and D126 12 V. 7 Ah battery Product ID Product Description 07050 Addressable photoelectric smoke detector 070501H Addressable photoelectric smoke and heat detector 07050B6 Addressable detector base D7042 Multiplex eight-input remote module D7042B Multiplex eight-input remote module in box 07044 MuItipIesingIe-input module D7044M Mini pJi'tiplexsinge-input module D7048 Multiplex octal driver D70488 Multiplex octal driver in box D7052 Multiplex dual-input module D7053 Multiplex input-output module FMM-7045 Single-action manual station FMM-7045-D Double-action manual station Category Detectors and Detector Bases )n. .. .... . 1t- •:' -, Fire Alarm Systetr:s I D7039 Multiplex Expansion Module • _; .•I• ..... - ' r Has two Class B (Style .4) multiplex buses (supports addresses 9 to 255) Provides one CãA (Style 6) multiplex bus (supports addresses 9 to 128) Expands number of user codes to 100 PINs Increases event history buffer to 499 events Compatible with RPS Easy to install The D7039 Multiplex Expansion Mcdu.e is designed to enhance the conventional' features oL'the D7024 Fire Alarm Control Panel (FACP). The D7039 connects directly to the FACP and results in a total of up to 255 addressable points. The D7039 also increases the number of relay outputs to 58, adds an additional 400 events to the history buffer for a total of 499 non-volatile events, and also a1ows for up to 100 system users (an addition of 84 PINs from the base system). The D7039 can be programmed remotely from a laptcp or PC using the RPS Remote Programming Software. Parts Included Quant Component 1 D7039 board 1 D7039 Input-Output board 8 Staidoffs for input-output board 4 Staidoffs for 07039 board 1 Uterature pack Certifications and Approvals Listings and UL UOJZ: Control Units, System (IJL864) Approvals: CSFM 7185-1615:147 Factory Mutual Research I,- BOSH 2 1 D7039 Multiplex Expansion Module Installation/Configuration Notes Compatible Products The following products are compatible with the D7039 Multiplex Expansion Module: Category Product ID Product Description Control 07024 Addressable and conventional FACP Panels D7024-EXP Addressable and conventional FACP for export Mounting Considerations The D7039 mounts onto the control panel board inside of the control panel's enclosure using connector pins. An input- output module mounts to the inside wall of the enclosure for field wiring. Wiring Considerations Refer to control panel's installation guide for additional wiring requirements. Maximum impedance: 50 Oat +20C (+68F) nominal Distance (approximate) Size .1170 m .10 2 1810m 15 mm2 .3800 it 18 AWG 5950 ft 16 AWG Note: Do not use shielded cable. Twisted pair is acceptable but not recommended. Note: If used in fire applications, a minimum of 18 AWG wire is required. Technical Specifications- - Environment: Indoor, dry Current (load): 100 mA maximum each bus Resistance (bus wiring): 500 maximum the Voltage (input) 24 VOC nominal 07039 Multiplex Expansion Module D7039 Amóricas- Mid 164a "A Mc eGiflc Bdsch Security Systems Bosdt Security Syetem BV r-8osch Security Systems Pte Lid BOSCH 130 Pennton Parle.vay P0 Box 80002 38CJalen emimp.n 0 Fairpori New YOrk, 14450 USA 560018 Elndhoven, The Netherlands Srngapore 577180 Phone'+l 585 223 4080 Phone*31 (0)4027 8355 Phoi're +8563193450 lFax.'+1S02890096 Far431(0)402786668 . F&+6563193499 secunty.seIes@us.boitch.com emeasecuntysystemsosch.coni prriete@bot ( p*.bOséurltus. hUpw.bothsecticàm -, 4flp:fw.boSchtisUrityd k Data eijbject to change without notice I Phnted in USA I 45147en01 116. Sep 2005 Fire Alarm Systems I D7044M Multiplex Mini-Single-input McdtJe I V I .IU%.F - Use with D7024 Addressable FACPs Fits into a standard single-gang back box Easy addressing using rotary switches. Low current draw UL Listed The D70441v1 Multiplex Mini Single-input Module connects a PIE ining nor-maIly-oen (NO) contact to the multiple bus of a D7024 Compatible Products Addressable Fire Alarm Control Paiel (FACP). Use the The following products are compatible with the D7044 D7044M supervised input in a Class B configuration. All Multiplex Single-input Module: operating power for the input module is dr.wn from the . Category Product ID Product Description FACP. Control 07024 Addressable FACP Rotary swithes allow convenient address setting.. Parels D7024-EXP Addressable FACP for export FAcdues 07039 Multiplex expansion module Parts included D7039R Multiplex expansion module retrofit kit Quent. Component 1 07044M module 1 221 kfl end-of-line (OL resistor (PIN: 25899) 1 Literature pack Certifications and Approvals Listings and UL UOXX: Control Unit Acsssories, System Approvals: (UL864) CSFM 716.5-0801:177 BOSCH Mounting Thz D7044M fits in a single-gang back box to which the device it is monitoring is attached. Viring. Connections for the D7044M are made using the 16 AWG (1.5 mm) flying leads from the device. All wiring is power Lmited and supervised. Ncie Do not use shielded wire. Note7 Supervise the input 1p with the supplied EOL resistor. - /... 2 1 07044M Multiplex Mini Single-input Module Technical Specifications ~15~4_M,Multiplei Mini Single- input Module Enclosure Design Color White Dimensions (HxWxD): 1.5625 in. x 2.75 in. x 0.6875 in. (4cmx7cmx1.75cm) Matenal ABS plastic Weight: 2.9 oz (82 g) Environmental Considerations Relative Humidity: lip to 93% noncondn:: Temperature (operating) +32°F t +120°F (0°c. to t49°C) Input: One normally-open (NO) input supervised by 2.21 kfl EOL resistor. Power Requirernt(supplied from FACPs'mitiptex bus) - Current: 550 pA Voltage 11 7 12 VOC nominal - D7044M Multiplex Mini Single-input Module D7044M "cT TT'i BOSCH Fori ore information ease visit pl www.boschsecuritysystems.càm . : Modifications reseived I FO1U000968en.OI ?II3JO4 '. &. * BOScIi - t A -,7 *' - 'InientedtorIife - - - -- - - D7033 LCD Keypad The D7033 LCD Keypad combines remote annunciator and controller functions for fire alarm systems controlled by the D7024 Fire Alarm Control Panel (FACP). It operates identically to the user interface on the 07024 FACP. You can connect up to four 07033 keypads to a D7024. Also use it to program the D9068 Fire Digital Alarm Communicator Transmitter (DACT). The D7033 allows remotely starting local system tests, system programming, system control, and viewing the system's event log. Passcode protect access to system functions allowing installation in areas open to the general public. The two-line, 32-character LCD (liquid-crystal display) annunciates system status and events. The top line provides general system status information, while the bottom line identifies specific devices or procedures. An internal sounder signals alarm and trouble conditions and annunciates keystrokes during programming and control procedures. Four status LEDs indicate power, alarm, trouble, and silenced conditions. A pull-out slide. with operating instructions fits behind the mounting base. Listings and UL UOXX: Control Unit Accessories. System (1JL864) Approvals: CSFM7165-1615: 147 ' Compatible with the D7024 FACP Two-line, 32-character1 alphanumeric LCD display - Status LEDs identify alarm, trouble, power, and silenced conditions Address setting by jumper Remotely control system including commands and programming Passcode protection controls system access Low-profile design Factory Mutual Research NYC/MEA (12-92-E, Vol.7 and Vol. 14) nflgN- -J Compatible Products The following products are compatible with the D7033 LCD Keypad:. Category Product ID Product Description Control Panels D7024 FACP D7024EXP FACP for export Keypads and D1030X LED annunciator Annunciators D7030XS2 LED annunciator D7030X58 LED annunciator Transmission 09068 Fire DACT Devices Mounting /' Mount the 07033 on asingle-gang or four-inch square back box. Wiring Guidelines Do not share keypad wiring with multiplex, telephone, or NAC wiring. www.boschsecurlty.com 2..L o3:LD Keai ..:. Use a minimum of 22 AWG (0.8 mm) four-wire cable; but do not use twisted pair or shielded cable. Note A minimum of 18 AWG (1.2 mm) cable is needed for NEC-NFPA-72. Do not exceed 1000 ft (305 m) between the control panel and the remote keypads. Do not exceed the total amount of keypad wiring permitted per system which is limited to a maximum of 4000 ft (1219 m). Number of keypads Do not connect more than four keypads. Place up to two keypads along any single 1000 ft (305 m) run of 22 AWG (0.8 mm)wire. Three keypads can be used on any single 1000 ft (305 m) run of 18 AWG (1.2 mm) wire. Environmental Considerations Relative Humidity: 5% to 85% at +86°F (+3(°C), non-condensing Temperature (Operating): . +32°F to +122°F (0°C to +50°C) Mechanical Properties Dimensions (H x W x D): 4.6 in. x6.3 in.x 1.2 in. (12cmx 16cmx3cm) Power Requirements Current (alarm): 100 mA Current (standby): 80 mA Voltage (operating): 12 VDC nominal .. 07033 LCD Keypad 07033 Am.rlcea: Bosch Security Systems 130 Purinton Parkway Fairport. New York, 14450, USA Phone: +1585 2234080 Fax: -1800 289 0096 escurity.oaies@usbosch.com www.boschuecurity.us Europe. Middle East. AM= Bosch Security Systems ax. P.O. Box 80002 5600 JO Eindhoven, The Netherlands Phone: +3140 2783855 Fax. +314027 86668 emes.necurttyuystemx@bosch.com www.boscflsecurity.com AsIftfleft Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 517180 Phone: +65 6319 3480 Fax: +65 6319 3499 apr.oecuritysyatemsbonch.com www.boxchsecurity.com Reprusent.d by Bosch Security Systems 20061 Data subject to change without notice F13124950591 Cur. en-US. V3. 34 Jan 2008 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1615:147 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTER: Bosch Security Systems, 130 Perinton Parkway, Fairport, NY 14450 Contact: Frank Mioduszewski (585) 678-3368 FAX (585) 678-3263 DESIGN: Model D7024 fire alarm control unit. Power limited, local, automatic, manual, noncoded, remote station, central station, waterfiow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: D7024 Control Unit D7034 4-Zone Expander D7033 Keypad D7035, D7035B Expanded Relay Module 25899 End-of-line Resistor D184A City Tie Kit D185 Reverse Polarity Module D7014 Class A Adapter D7039 MUX Expander. D7038 Remote NAC Expander D7015 Class A NAC Module D7042 Eight Zone Expander D704213, D7044, D7044M, D7052 Multiplex Expander Module D7048, D7048B Octal Driver Module 07053 Multiplex Input/Output Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 8th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-0801:177 07-05-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results );)) and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation tL.JJ criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 29, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division 9 'n-It SPECIFICATIONS Nominal Voltage (V) 12V Nominal Capacity 20hour rate (0.9A to 10.50V) 1 P lOhour rate ( 1.8A to 10.50V) 18Ah 5hour rate (3.06A to 10.20V) 15.3Ah 1C(18ALo9.60V) 8.1Ah 3C (54A to 9.60V) 6.48Ah Weight 13.82 Lbs. (6.283 kg) Internal Resistance (at 1KHZ) 10 m2 Maximum Discharge Current for 30 seconds: 360A Maximum Discharge Current for 5 seconds: 720A Operating Temperature Range Charge 0°C(32°F) to 40°C (104-F) Discharge -15°C(5°F) to 50°C (122°F) Storage -15°C(50F) to 40°C (104°F) Charge Retention (shelf life) at 20°C (68°F) 1 month 92% 3 month 90% 6 month 80% Charging Methods at 25°C (17°F) Cycle use: Charging Voltage 14.4 to 15.OV Maximum Charging Current 5.4A Standby Use: Float Charging Voltage 13.50 to 13.80V No current limit required Life expectancy: Cycle Use: 100% depth of discharge 250 cycles 80% depth of discharge 350 cycles 50% depth of discharge 550 cycles Standby Use: 3-5 years Case Material ABS (94-1-113 & 94V-0 flame retardant case) Terminal F3 Maintenance-Free Rechargeable Sealed Lead-Acid Battery DIMENSIONS mm(inch) (M5 Bolt) tel I.o 76±1 (299ie.34) IC . .LI1 L ° Discharge Time VS. Discharge Curreit (25°C) U, . , 1 41111 9 IN 2 41111 9 I— — -- 1191 Discharge Time IVIK Battery 1645 South Sinclair Street Anaheim, California 92806 Toll Free: 800-312-9253• Fax: 114-937-0818• E-Mail: sales@mkbattery.com FMM-100 Series Die-cast Metal Fire Alarm Manual Stations Single or dual action Terminal connections Gold-plated alarm contacts for corrosion resistance Surface or weatherproof back boxes The FMM-100 Series is a family of versatile, high-quality, metal fire alarm manual stations. Single-action or dual- action models are available. All models come with a key lock and contain gold-plated contacts to resist corrosion. Functions -: Operation Single-action When the baron the front of the manual station is pulled, it latches open and is easily visible from 50 ft -(15 m). Reset the activation bar by opening the manual station with the key and placing the activation bar in its normal upright position. An optional scored acrylic break rod is available. Dual-action With the dual-aôtion configuration the upper bar on the front of the manual station rotates inward allowing the activation bar to be grasped and operated by a single hand. e.fificatjofls and. NON s:. Listings and UL UNIU: Boxes, Non-coded (UL38) Approvals: UL UNIU7: Boxes, Non-coded Certified for Canada (CAN! ULC5528M91) CSFM 71501615: 224 NYC/MEA (382-94-E, Vol. 3) Installation/Configuration Notes Compatibility Information Compatible with all Bosch Security Systems Fire Alarm Control Panels. Mounting Considerations The FMM Series manual stations can be surface mounted on either the FMM-100BB-R Surface-mount Back Box or the FMM-100WPBB-R Weatherproof Back Box. They can also be flus ,óunted on a standard single-gang back box. Note When properly mounted on the• FMM-100WPBB-R Weatherproof Back Box, these manual stations meet UL requirements for outdoor use. To comply with ADA standards, the manual station must be less than 48 in. (1.2 m) above the floor for front wwwtucanobrasil.com.br :Odernglnforrnation : FMM-100SATK Single-action Manual Station (red) FMM-100SATK FMM-100SATK-NYC Single-action Manual Station for FMM-100SATK-NYC New York City FMM-100DATK Dual-action Manual Station (red) FMM-1000ATK Hardware Accessories D102 Replacement Key D102 FMM-100BB-R Surface-mount Back Box (red) FMM-100BB-R FMM-100WPBB-R Weatherproof Back Box (red) FMM- 100 WPBB-R FMM-100GR Scored Acrylic Breakrods FMM-100GR Distribuicao: Alarmes Tucano Ltda R. Des. Antonio de Paula, 3577 - Boqueirao - Curitiba - Pr Fone/fax: (41) 3286-2867 - Cep: 81720-280 tucano@tucanobrasiicombr wwwtucanobrasiicombr CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1615:224 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: Bosch Security Systems, 130 Perinton Pkwy, Fairport, NY 14450 Contact: Frank Mioduszewski (585) 223-4060 Fax (585) 421-4263 DESIGN: Model FMM-100, followed by DAT (Dual Action with terminal strip) or SAT (Single Action with terminal strip) may be followed by K or K-NYC (key lock with single contact) or *2CK (Key lock with dual contacts) noncoded manual pull stations. *FMM IOOBB indoor back box. Suitable for outdoor use when installed with Model FMM-100WPBB back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC, 125 VAC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Ustee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. XLF: 7150-1408:107 *Rev. 08-08-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation L...J1 criteria. Refer to listee's data sheet, installation instructions and/or other suitable Information sources. Date Issued: JUNE 14, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager ('i:[ - - ' - '° -- - '• C' " ntediro life * ' •,. . - -. ,:- - LM L46' jt i1ti D263 Series Photoelectric Smoke and Smoke and Heat Detectors The D263 Series includes the following detector models: Model Description D263 Two-wire D263Th Two-wire with 135°F (57°C) heat sensor D263THC Two-wire with 135°F (57°C) heat sensor and auxiliary relay 02631HS° Two-wire with 135°F (5 7°C) heat sensor and sounder * Sounders produce 85 dB at 10 ft (3 m). Each of the D263 Series Detector models is UL Listed and works with commercial fire protective signaling and household fire warning systems. Each model detcts smoke particles produced during wood, paper, and fabric combustion. The 0263 Series Detector models use an infrared (IR) LED light source and a silicon photodiode to measure light in a chamber. A fine screen covers the chamber to deter insects and to reduce dust accumulation and nuisance alarms. During a fire, smoke particles reflect light onto the photodiode. When the photodiode measurements exceed the alarm threshold, the detector signals an alarm condition. After the alarm condition clears, interrupt power at the control panel to reset the detector. 12 V or 24 V Input Designed for commercial or residential use " Two-wire application Light-emitting diodes (LEDs) indicate the status of the chamber, power, and alarm Removable terminal block to simplify wiring connections Cable connection point for voltmeter sensitivity test Trim Plate 1P280 for retrofit and remodeling purposes Use a 0132B Reversing Relay Module to activate the sounder (85 dB at lOft [3 m]). When using a 0132B, the LED does not latch on alarm. rr- + U1CtL —- Chamber Calibration Tests Check the sensitivity and calibration of any 0263 Series Detector model using a visual check, a magnet test, or a voltage measurement test. Visual check: When the detector's calibration is within the factory-listed range, the red alarm LED flashes once every 3.5 sec. If the detector's calibration is out of range for more than 24 h, the red alarm LED flashes once a second. Magnet test: Hold a magnet horizontally against the detector for about 10 sec and observe the LED. a If the detector is within tTactory-listed calibration range, It goes into alarm and the Alarm LED latches on. If the detector is too sensitive, the LED rapidly flashes six times (once every half second) and the detector goes into alarm. If the detector is not sensitive enough, the LED slowly flashes four times, once every 2 seconds, and the detector goes into alarm. If the detector does not operate, it does not signal an alarm. www.boschsecurity.com Voltage measurement test: Use a D1005 Test Cable and a digital voltmeter to measure the voltage and compare the results with the factory-listed sensitivity range. MI Models Listings and UL UROX: Smoke - Automatic Fire Detectors (U1268) Approvals: UROX7: SmokeS Automatic Fire Detectors certified for Canada (S529) c-UL-us CSFM: 7272-1615:134 NYC/MEA: 274-93-E, Vol. VII D263THC and D263THS only Complies with: Hong Kong Fire Services Department (HKFSD) --- .r 1nstalIation/configur-to Notes , 1 i1stLLL. Use smoke detectors for detection circuits that protect people. Use heat detectors for circuits that protect property. Compatible Products The following products are compatible with the D263 Series detectors: Category Product ID ProductDescdptlon Control Bosch Security Systems makes no claim written, oral, or im- Panels plied that the D263 Series detectors work with any two-wire control panels except those specified in the Control Panel Compatibility chart in Technical Service Note (P/N: 31866). Modules D132B Reversing relay module Mounting The detector has a mounting plate that attaches on a standard four-inch back box. For commercial and industrial installations in accordance with NFPA 72, space each detector 30 ft (9.2 m) apart. Wiring The terminal block accepts up to 12 AWG (2.3 mm) wire. You can remove the terminal block from the detector for easier wiring. The terminal block snaps in and out of the detector. 'T Environmental Considerations Radio Frequency Interference No alarm on critical frequencies in the range (RFl) Immunity: . of 26 MHz to 950 MHz. Relative Humidity: Up to 93%, non-condensing Temperature (operating): +32°F to +120°F (0°C to +40°C) Mechanical Properties Dimensions (Diameter x H): 5 in. x 2 in. (12.7 cm 5.1 cm) Material: High impact, fire retardant ABS plastic Relay Contacts Auxiliary Form C: 1 A. 120 VAC/30 VDC at 1 A. 30W maximum Power Requirements Current Draw (alarm): Determined by control panel Current Draw (standby): 0.080 mAat 12 V.0.1 mA maximum Current Draw (start-up): 0.12m A Current Draw (trouble): Di mA maximum Power-up Time: 22 sec maximum RMS Ripple (maximum): 25% of DC input Voltage (stand-by); 8.5 VDC to 33 VDC '.Oidering..InformatiOn . .T4V5 .'-r—'-gWnr -,--'-• -t-"- D263 Two-Wire Smoke Detector D263 D2631H Two-Wire Smoke/Heat Detector D2631H D263THC Two-Wire Smoke/Heat Detector with D263THC Auxiliary Relay D263THS Two-Wire Smoke/Heat Detector with D263THS Sounder kcess1.ories 01005 Test Cable 01005 DT-2 Detector Removal Tool OT-2 1P280 Trim Plate 1P280 Ed Eump.. Middle But Micas Ajnedenm Bosch Security Systems B.V. Bosch Security Systems, Inc. P.O. 80* 80002 . 130 Peflnton Paricway $600 JO Eindhoven, The Netherlands Fairport, New York, 14450. USA Phone,+ 3140 2577 284 Phone: +1800 289 0098 Few. .3140 2577 330 Fax: 41585 223 9180 emeL3Icuritysystem3@b00ch.com s.curlty.511aa15u5.bOsch.com www.boschsscurlty.com www.boochsecurlty.us C Bosch Security Systems 20061 Data subject to change without notice 11327854859 I Cun en-US, V3. 28 Sep 2006 AsI*Peclflm Bosch Security Systems Pt. Ltd 38C John Pemimpin Singapore 571180' Phone: +65 6319 3450 Foe, +85 6319 3489 apr.secitrItysyotemsboschcom www.boscho.csrity.com Represented by CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE U00 LISTING No. 7272-1615:134 Page 1 of .1 CATEGORY: Photoelectric Smoke Detector LISTEE: Bosch Security Systems, 130 Perinton Parkway, Fairport, NY 14450 Contact: Frank Mioduszewski (585) 678-3368 FAX (585) 678-3263 DESIGN: Models D285, D285DH, 02851H, D263, D263TH, D273, D273TH, D273THS, D263THC, 0263THS, D273THR, D273THC, 02731S, D273THCS, D273THSR, D273THE, D273ES and D273THES smoke detectors. Model D285TH, D263TH and D273THxx employ an integral 1350 fixed temperature heat detector. This heat sensor is Intended for use only as a supplemental device to assist the smoke detector. *Model D285 series are separable detector heads which operate with separable base Models D287, D288, 0292, 0293A, 0293E and D293S. *Models 0263 and D273 series detectors' are nonseparable detector heads with terminal blocks and do not operate with separable bases. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 33.0 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control unit. Models D285 and D285TH are intended for use with separately listed bases. Model D285DH is intended for use with separately listed Duct Smoke Detector Housing Model D341 or 0342 (CSFM Listing No. 3240-1615:181) or Model 0340 (CSFM Listing No: 3240-1615:184). Refer to listee's Installation Instruction Manual for details. FORMERLY: 7272-0801:162 do- Re#429-2007 jw This listing Is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 29, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division ®POTTER.VANE TYPE WATE RFLOW The Symbol of Protection ALARM SWITCH WITH RETARD. U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50mm thru 200mm). LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterflow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover. tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC and CSFM Listed, FM and LPCBApproved, NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI (31 BAR) Minimum Flow Rate forAlarin: 10 GPM (38 LPM) Maximum Surge: 18 FPS (5,5 mIs) Contact Ratings: Two sets of SPDT (Form C) 15.oAinps at 1251250VAC 2.0Ampsat30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA4IIP54 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/120°F, 4,5°C/49°C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizà Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8" BS 1387 pipà 50mm thru200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler. NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National FireAlarm Code NFPA-72 Optional: CoverTamper Switch Kit, StockNo. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a Slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 11/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/811 (50mm 4mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install thftddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (6 n-m) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • wwwpottersignat.com PRINTED IN USA MKT. #8800001 - REV w PAGE! OF 2 MPG. #5400761 -7/02 FIG.4 To remove knockouts: Place screwdriver at edge of knockouts, not in the center. INtO. I76I-4 (E)POTTER The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME FIG. 1 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL DWOI Rode 23.J CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 2 OPTIONAL TAMPER SWITCH RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS. A '6" SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO B. TO INSTALL, DRILL HOLE AS INDICATED: PIPE SIZE HOLE SIZE 2' to 2 1/2" I 1/4W +1/8" -l/IS (50mm to 65mm) (33mm ±2mm) 3 to 8" 2' ±1/8" (80mm to 200mm) 50mm ±2mm) Cover Tamper (with cover in place) DIRECTION OF En WATERFLOW C N.O. N.C. (WIG) (RRD)(BLK) \ DWG. 76I-30 TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL 50F1.-'LBS (66 n-m) OF TORQUE MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) o o 1 A 10-25 B 20-40135-15150-7o C 0 50-70 E 60-90 FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: I. The Model VSR-P has two switches, one can be used to operate a central Station, proprietary or remote Signaling unit, while the other contact is used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude EEI.L moisture. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. I). 2 SETS OF NORMALLY OPEN CONTACTS WATERFLOW ZONE IIOLRFROM CLOSE ONALARM ON FIRE PANEL FIRE PANEL THE NC. ANDN.0. MARKINGS ON POSI11VE DC THE SWITCH ARE FORANALARM ORHOTAC CoNDmON. NEGATIVE DC OR THE CONTACTS ARE REVERSED NEtYIRAI4C WHEN THE DEVICE IS IN THE NORMALCONDITION. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system shoui$rin accordance with applicable NEPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protectionsystem that this system must be tested in accordance with the testing instructions. PRINTEDJNUSA MKT. #8800001. REV W PAGE 2OF2 MFO. #5400761-7102 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTEC11ON OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE N3,00100 LISTING No. 7770-0328:001 Pagel of 1 CATEGORY: Valves/Switches LISTEE: Potter Electric Signal Co., 2081 Craig Road, St. Louis, MO 63146 Contact: Bill Witherspoon (314) 878-4321 Fax (314) 878-7264 DESIGN: Vane and pressure type water flow alarm switches listed below. Refer to listee's data sheet for detailed product description and operational considerations. Vane Types: VSR-CF VSR-D VSR-F VSR-SF VSR-FE-2 VS-SP VS-F VSR-SFG VSR-SFT VSG VSR VSR-S VSR-C VSR-ST VSR-SG Pressure Type: WFS-B WFSR-C WFSPD-B PSIO PS-10A PS-1•00A WFSR-F PSIOO INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number and UL or FM label. APPROVAL: Listed as waterflow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models may be used in wet or dry systems. Model VSR-CF is for use on K, L or M copperpipe (2", 2-1/2", 4") and listed CPVC pipe (2", 2-1/2", 3"). Model VSR-SF for use on 1", 1-1/4", 1-1/2" and *2 steel, copper or listed plastic pipe. Model' VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4", 1-1/2" and *2 plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2", 2-1/2", 3", 3-1/2",4", 5", 6", 8" and 10" pipe. *Model VSR is for use on steel pipe sizes from 2" through 8". Vane type switches may be used outdoors when the outdoor temperature never falls below 40°F. *Rev. 05-17-2007 Jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering Itt 1i has reviewed the test results and/or other data but does not make an independent verification of any claims. This 11ting is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation QJJ criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 11, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division POTTER CE The Symbol of Protection SUPERVISORY SWITCH UL, ULC, and CSFM Listed, FM Approved, NYMEAAcccpted, CE Marked Dimensions: 4.75"L x 2.25"W x 7.2"H (stem extended) 12,1cmLx5,7cmWx 18,3cmH Weight: 135 lb. (0,61 kg.) Enclosure: Cover - Die-cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper Resistant Screws, Optional cover tamper kit available Mounting: 1/2" NPT Contact Rating: PCVS-1: One set ofSPDT (Foam C) PCVS-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: -40°F to + 140°F (-40°C to 60°C) NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. Indoor or Outdoor Use (Not for use in hazardous locations. See bulletin no. 5400694 PIVS-U-EX for hazardous locations.) Conduit Entrances: Two knockouts for 1/2" conduit provided. Service Use: PCVS-1 StockNo. 1010107 PCVS-2 Stock No. 1010207 Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 The Model PCVS is a weather proof and tamper resistant switch for tool to remove. The tool is furnished with each device and should be left with monitoring the open position of fire sprinkler control valves of the post the building owner or responsible party. Replacement or additional cover indicator, butterfly and other types. Depending on the model, one or two screws and hex keys are available. See ordering information. SPDT (Form C) contacts are provided which will operate when the valve position is altered from an open state. OPTIONAL COVER TAMPER SWITCH: A field installable cover tamper switch is available as an option which maybe used to indicate removal The unit mounts in a 1/2" NPT tapped hole in the post indicator or butterfly of the cover. See ordering information. valve housing. The device is engaged by the indicating assembly of the post indicator or the operating mechanism of the butterfly valve, actuating TESTING: The PCVS and its associated protective monitoring system switch(es) when the valve isfully open. The unit should be installed where should be tested in accordance with applicable NFPA codes and standards it is accessible for service. and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). The cover is held in place by two tamper resistant screws that require aspecial ORDERING INFORMATION MODEL I DESCRIPTION STOCK NO. PC VS-I Potter Control Valve Switch (single switch) 1010107 PCVS-2 Potter Control Valve Switch (double switch) 1010207 -- Cover Screw , 5490344 -- Hex Key for Cover Screws and Installation Adjustments 5250062 PBK-S Pratt Butterfly Valve Kit - Up to 12" (300mm) 0090133 PBK-L Pratt Butterfly Valve Kit - 14" (355mm) and Up 0090132 PVK Pratt Valve Kit 1000060 -- Optional Cover Tamper Switch Kit 0090131 KBK Kennedy Butterfly Valve Kit 0090143 For pressure reducer type valve installation kits (if required) contact valve manufacturer. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 631464161 • Phone: 800-325-3936/Canada 888-882-1833 • wwwpottersignal.com PRINTED IN USA MICt #8820001 - REV PAGE lOP 4 12/01 D POTTER The Symbol of Protection FIG. 1 DIMENSIONS FIG. 2 PCVS-19 -2 CONTROL VALVE SUPERVISORY SWITCH PARTS 4.75 • (12.1cm) (5,7cm) --2.00- - 3.00 (7.6cm) (13,2crn) L W 6.20 (1:m) q2.m oJ 1.12 (20.cm) I ROD RMAMD 1.o _f.12(o.30cm) NW •REpKAwAv SECTION REMOVED II 3.12 II (7.9cm) I I ii I II II I c,,vo ___________ DWC. p980- I I I j (WHITE) (RED (RIACA KNOcICOUTS FOR ELECTRICAL CONNECTIONS GROUND SCREW TRIP WOO LOCKNIC SCREW CT HEAD SCREW LE NUT ROD TYPICAL INSTALLATIONS ON POST INDICATOR VALVE HOUSINGS (SEE FIGS. 3 THRU 6) Refer to Fig. 2 for the location of pails described in the following instructions. NOTE: Ifthe sprinkler system is in service the owner or authorized representative should be notified, before any work is done on the system, that the valve controlling the water supply to the system may be closed for periods of time during the installation and testing of this device, resulting in all or portions of the system being inoperative during these periods. If the system is not in service and valve is closed, be sure that opening the valve will not allow any unwanted water.flow due to openings in the system, such as heads off, broken or incomplete piping, etc. Position the valve to filly open ("OPEN" should appear in the window of the housing). Partially close the valve while observing the direction that the target assembly moves. Reopen the valve. lithe valve housing is predrilled with a 112" NPT for installation ofa monitoring switch, remove the 1/2' plug and filly open the valve. Make sure that "OPEN" appears in the window of the housing. GO TOS1'EPNO. 6. Remove the head and target assembly (consultation with valve manufacturer is recommended). If the target assembly moved up as the valve was closed, measure the distance from the bottom of the head to the lower part of the target assembly' that will contact the trip rod of the PCVS (see Fig. 3). This is usually a plate or baron the targetassembly, on aside adjacent to the"OPEN/SHUT" plates. Subtract 1/8' from the measurement. If the target moved down as the valve was closed, measure the distance from the bottom of the head to the upper portion of the target assembly that will contact the trip rod of the PCVS (see Fig.-4). Add 1/8' (3,2mm) to this measurement. Mark the housing at the proper location. Using a 23/32" (18,2mm) drill bit, drill and then tap 1/2' NPT in the housing on the side that coincides with the portion of the target assembly that will engage the trip rod of the PCVS. Replace the head and target assembly. Loosen the socket head screw that holds the nipple in the PCVS and remove the nipple. Screw the locknut that is provided onto the nipple. Screw the nipple into the 1/2" NPT hole in the valve housing. hand tighten. Tighten the locknut against the valve housing to secure the nipple firmly in place. Insert a scale or probe thru the nipple to measure the distance from the open end of the nipple to the target assembly. Subtract 1/2' (12,5mm) from this measurement. NOTE: In some cases, it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. II. Loosen the locking screw that holds the trip rod in place and adjust the rod length, from the end of the collar to the end of the rod, using the dimension determined in Step 9. Tighten the locking screw to hold the rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (I) inch long notched section (see Fig. 7). Reinstall trip rod and repeat Step II procedure. Partially close the valve (3 to 4 revolutions of the handle/hand wheel). Slide the PCVS unit as far as possible onto the nipple, observing which direction the rod will move when the valve is closed. Orient the device to actuate the switches when the valve is open. Tighten the socket head screw in the collar. Carefully open the valve to the fully open pOsition. As the target moves to the open position it should engage the trip rod and actuate the switch(es). There should be a minimum overtravel of 1/2 revolution of the handle/hand wheel after the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). Slowly close the valve. The switch must operate during the first two revolutions of the handle/hand wheel or during 1/5 of the travel distance of the valve control apparatus from its normal cdition. NOTE:' Small adjustments of the targt position may be necessary (consultation with valve manufacturer is recommended). Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation and the signaling system. Check that all electrical and mechanical connections are secure. When the installation and testing are complete, return valve to its proper position. iS. Alternative installation for other post indicator valve housing shown in Fig. Sand 6. PRINTED IN USA MICE fl8820001- REV PAGE 2 OF 4 12/01 ePOTTER PC VS-i, -2 CONTROL VALVE the pymboi or i'rorecuon SUPERVISORY SWITCH FIG. 3 FIG, 4 FIG. 5 FIG. 6 METAL PLATE REPLACES GLASS TARGET MOVES 0 STEEL UP AS TAMPER TRIPPING VALVE T' ,,. SWITCH BLOCK - OPEN IS SHUT 0 PENS REPLACES OPEN 0 TAMPER 0 MARKER o OPE - SWITCH UT TARGET TAMPER MOVES LOC KNUT 0 1/8 SWITCH DOWN AS SHUT T VALVE MARKER TARGET ASSEMBLY FLEXIBLE II IS SHUT CONDUIT (28.9cm) TARGET HOOD MOVES MOVES DOWN AS VA VALVE UP AS IS SHUT VALVE IS SHUT DWG. #960-30 Notes: Subject to the approval of the "authority having jurisdiction" the alternate method of installation shown in Fig. 5 may be used. In this method, one of the glass windows of the housing is replaced with a 1/4" thick metal plate that is cut to fit in place of the glass and drilled and tapped to receive the 1/2" NPT pipe nipple. In some cases it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. If the target is stationary and a hood arrangement is used, such as is shown in Fig. 6, the hood must be drilled with a 23/32" drill and tapped with a 1/2" NPT. The center line of this hole should be 1/8" below the portion of target assembly that strikes the PCVS trip rod. The 113/8" dimension shown is for a Clow Valve. Flexible conduit must be used for this type of installation. TYPICAL INSTALLATION ON A BUTTERFLY VALVE (SEE FIGS. 9 AND 10 Refer to Fig. 2 for location of parts described in the following instructions: B!. Remove the 1/2" NPT plug from the gear operator case. 87. Loosen the locking screw that holds the trip rod in place. Estimate trip rod length required and extend slightly past that point. Slide the PCVS unit as far as possible onto the nipple, observing which direction the rod will move when the valve is closed. Orient the device to actuate switches when valve is open. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (I) inch long notched section (see Fig. 7). Reinstall trip rod and repeat Step B? procedure. BS. Remove device from nipple and withdraw trip rod 1/32" (0,80mm) (this dimension is important). Tighten the locking screw to hold the rod in place. Re-install the device on the nipple. Tighten the screw in the collar against the nipple. NOTE: In some cases it may be necessary to remove the gear box cover to ensure correct operation (consultation with the valve manufacturer is recommended). Carefully open the valve to its full open position, as the boss on the gear hub moves to the open position it must engage the PCVS trip rod and actuate the switch(es). There should be a minimum overtravel or revolution of the crank or hand wheel after the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). NOTE: Slight adjustment of gear stops may be necessary to prevent overtravel of the trip rod (consultation with valve manufacture is recommended). 810. Carefully close the valve. The switch(es) must operate during the first two revolutions of the crank or hand wheel or during 1/5 of the travel distance of the valve control apparatus from its normal condition. Bli. Complete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation and signaling system. Check that all electrical and mechanical connections are secure. B12. When the installation and testing are complete, return valve to its proper position. Loosen the set screw that holds the nipple in the PCVS and remove the nipple. Screw the locknut that is provided onto the nipple. Screw the nipple into the 1/2" NPT hole in the gear operator - hand tighten. B9. Tighten the locknut against the case, to secure the nipple firmly in place. Partially close the valve (3 or 4 revolutions of the hand wheel or crank). Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. FIG. 7 BREAKING EXCESSIVE ROD LENGTH SWITCH FIG. 8 I1T PLATE TERMINAL CAUTION: Anuninsulatedsectionofasingleconductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. DWG. *9811-13 - PRINTED IN USA MKT. #3820001. RRVT PAGE 3 OF 4 12101 (E)POTTER The Symbol of Protection PCVS-1, -2 CONTROL VALVE SUPERVISORY SWITCH iTt' GRINNELIJKENNEDY INDICATING BUtTERFLY VALVE FIG.8 DRESSER INDICATING BUTTERFLY VALVE FIG. 10 (13mm) TYPICAL PRESSURE REDUCER TYPE VALVE INSTALLATION FIG. 11 COLLAR LOCKNUT NIPPLE i/is' MIN. DWG. 1980-10 This figure shows theModel PCVS mounted on the valve yoke, with a bracket supplied by the valve manufacturer, to supervise a pressure reducer type valve. Note: This application is subject to the approval of the authority having jurisdiction. LO 90 BRACKET AND LOCKNUTS SUPPLIED WITH P8K MOUNTING KIT 0 MODEL PBK.L Stock No. 0090132 MDT4S Actuator) MODEL PBK-M Stock No. 0090146 (MDT-3S Actuator) MODEL PBK.S Stock No. 0090133 (MDT-2S Actuator) Pratt Butterfly Valve Kit as used to mount a PCVS on a Pratt Model .IBV Valve. Kits contain: Bracket, nuts and instructions Note: This application is subject to the approval of the authority having jurisdiction. PRINTED IN USA DWG. 191 Pratt Valve Kit as used to mount a PCVS on a Pratt Model P1VA Valve. Kit contains: Instructions, template, screw and nut. Note: This application is subject to the approval of the authority having jurisdiction. MKT. #8820001. REV 12/01 TYPICAL ELECTRICAL CONNECTIONS Please Note: This device should be-wired in accordance with the applicable parts of the National Electrical Code, allstate and local codes, applicable NFPA Standards and the-requirements of the authority having jurisdiction. FIG. 14 LOCAL CRCUT R.O. TO POWER FOR CON. 4 [3\INDICA1ING IN0ICATW4G DEVICE __J DEVICE TO suFevisoay cuauit ly.o: OF CONTROL PANEL END OF LINE cou INC < RESISTOR I OWr. #980-12 Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION OPEN VALVE POSITION CLOSED VALVE POSITION COM . CON. N.O. SWI14!r1 SW II CON. CON. SW #2 SW #2 DWG. 1980- 11 Switches Shown in Valve Open Position PAGE 4 OF 4 PBK - PRATT IBV BUTTERFLY PVT( - PRATT PIVA POST VALVE KIT INDICATOR VALVE KIT FIG. 12 1 (STOCK NO. 1000060) FIG. 13 MACHINE SCREW CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7770-0328:010 Page 1 of 1 Valves/Switches Potter Electric Signal Co., 2081 Craig Rd., St. Louis MO 63146 Contact: Bill Witherspoon (314) 878-4321 Fax (314) 878-7264 Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, PIV, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W WLS-S PS-40A PS-120A OSYSU-2 OSYS-B PMS PTS-B OSYSU-1 GVS PCVS-1 PIVS-B ITS-S TTS-W PCVS-2• WLS PTS-C PS40 PSI20 *RBVS INSTALLATION: MARKING: APPROVAL: NOTE: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation and FM or Ut. label. Listed as sprinkler system supervisory switches. Formerly 7738-0328:010 Rev. 05-17-2007 Jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineeringtaf1 has reviewed the test results and/or other data but does not make an independent verification of any claims; This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 11, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division (E)POTTER ' Tk. O...,JI .f OSYSU-19 -2 OUTSIDE SCREW AI'41) YOKE VALVE 11W QUIULfl UI ri uwwiuii SUPERVISORY SWITCH. UL and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked / l OSYSU-1 Stock No. 1010106 OSYSU-2 Stock No. 1010206 GENERAL INFORMATION The OSYSU is used to monitor the open position of an Os & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, 'containing one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets ofSPDT (Form C) contacts. These switches mount conveniently to most OS & Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as 1/2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional cover screws and hex keys are available. See ordering information on page 4. Dimensions: 6.19"L X 2.25"W X 5.88"H 15,7cm LX 5,7cm W X 14,6cm H Weight: 2 lbs. (0,9 kg.) Enclosure: Cover - pie-Cast Finish- Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. Indoor or Outdoor use (Not for use in hazardous loáations. See bulletin no. 5400705 OSYS-U-EX for hazardous locations.) Temperature Range: -40°F to 140°F (-40°C to 60°C) Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use: - Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING The OS'YSU and its associated protective monitoring system should be inspected and tested in accordance with applicable NFPAcodes and standards and/orthqtflhority havingjurisdiction (manufacturer recommends quart&ly or more frequently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 0, wwwpottersignal.com PRINTED IN USA • • MKT. #8820004 - REV PAO1OF4 12101 () P OTTER OSYSU-1, -2 OUTSIDE SCREW AND YOKE VALVE The Symbol of Protection SUPERVISORY SWITCH FIG. 1 SMALL VALVE INSTALLATION - 1/2" THRU 21/2" (12,5mm THRIJ 63,5mm) SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2" TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2" (12,5MM). J-HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. CLAMP BAR CARRIAGE BC SLOTTED MOUNTING HOLES MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET BRACKET DWG. #979-3 SMALL VALVE INSTALLATION Remove and discard "C" washer and roller from the trip rod. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non-threaded portion of the valve stem. Loosen the locking screw that holds the trip rod in place ad adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark on the valve stem utilizing a 3/16" (4,8mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 1) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate when the trip rod moves out of the groove. Tighten the adjustment screws and all mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSØsition. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED INUSA MKr.#8820004- REV p PAGE 2OF4 12/01 () OSYSU-19 -2 POTTER OUTSIDE SCREW AND YOKE VALVE The Symbol of Protection SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" (76mm THRU 300mm) SIZES • 3" THRU 12" (76mm THRU 300mm) VALVES BRACKET USE CARRIAGE BOLTS. BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE BOLTS SLOTTED MOUNTING (2 REQUIRED) HOLES. MAY BE USED ROLLER FOR FINE ADJUSTMENT GROOVE OF SWITCH ON BRACKET. YOKE VALVE STEM TRIP ROD DWG. #979-4 GLAND LARGE VALVE INSTALLATION With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non-threaded portion of the valve stem. Mount the OSYSU Ioosly with the carriage bolts and clamp bar supplied. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one 1" (25mm) long notched section (see Tig. 5). Reinstall trip rod and repeat Step 3 procedure. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark of the valve stem utilizing a 3/8" (9,5mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU loosely with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. Tighten the adjustment screws and mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turihen the valve is operated from the FULL OPEN towards the QLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 3 OF 4 12/01 ORDERING INFORMATION MODEL DESCRIPTION STOCK NO. OSYSU-1 Outside Screw & Yoke-Supervisory Switch (Single switch) 1010106 OSYSU-2 Outside Screw & Yoke-Supervisory Switch (Double switch) 1010206 -- Cover Screw 5490344 - Hex Key for Cover Screws and Installation Adjustments 5250062 -. Optional Cover Tamper Switch Kit 0090131 For pressure reducer type valve installation kits (if required) contact valve manufacturer. OPEN VALVE POSITION CON. SW CON.: SW 12 CLOSED VALVE POSITION ,tcM.NO iW if SW 12 DWG. #979-2 ® POTTER Thn C,mhni nf Drnn,.#irn, OSYSU-1, -2 OUTSIDE SCREW AND YOKE VALVE J7IIIUUI UI U I UWI.,LIUII SUPERVISORY SWITCH FIG. 3 DIMENSIONS FIG. 4 PARTS MEN MEW RW SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL Owe. p523-3 CAUTION: An uninsulated section ofasingle conductorshould not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. TYPICAL ELECTRICAL CONNECTIONS LOCAL CIRCUIT 'I' N.O. INDICATING TO POWER FOR Cor- N.C. DEVICE INDICATING DEVICE TO SUPERVISORY CIRCUIT N.O. Lt—V END OF OF CONTROL PANEL LINE NC ¶ RESISTOR I DWG. 1979—I Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION BREAKING EXCESSIVE ROD LENGTH FIG. 5 PRINTED IN USA MICE #8820004. REV p PAGE 4 OF 4 12/01 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL F FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 97 LISTING SERVICE LISTING No. 7770-0328:010 Page 1 of I CATEGORY: Valves/Switches LISTEE: Potter Electric Signal Co., 2081 Craig Rd., St. Louis MO 63146 Contact: Bill Witherspoon (314) 878-4321 Fax (314) 878-7264 DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, PlV, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W WLS-S PS-40A PS-120A OSYSU-2 OSYS-B PMS PTS-B OSYSU-1 GVS 0C VS-1 P1 VS-B ITS-S TTS-W PCVS-2 WLS PTS-C PS40 PSI20 *RBVS INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Llstee's name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. NOTE: Formerly 7738-0328:010 Rev. 05-17-2007 jw .. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering Sff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ;•' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 11, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division SYSTEM SENSOR 4-Wire Photoelectric, Low-Flow Duct Smoke Detector System Sensor's Innovair DH 100ACDCLP reduces the spread of smoke through H VAC air duct systems, including low-flow applications. As a photoelectric detector, it's ultra-responsive to the large smoke particles commonly found in duct systems. The DH1 OOACDCLP uses low-flow, technology to sense smoke in the lowest air speeds, from 100 to 4,000 feet per minute. When smoke is detected, all interconnected units will initiate their relays. However, to quickly locate the fire source, only the detector sensing smoke Will alarm. Two DPDT Form-C relay contacts, connected to auxiliary equipment, can also be configured to prevent the spread of smoke through a particular area. The DH1 OOACDCLP is simple to install and maintain. Powered by 24VAC/DC or 120/240VAC, it can be easily mounted to round and rectangular ducts, from one to twelve feet in width, with outside mounting tabs. It also offers an adjustable telescopic sampling tube that can be used for duct widths up to 18 inches. This tube locks into place - no additional tools are necessary. Its modular construction allows for easy cleaning and field replacement of the power and sensor boards. Also simplifying maintenance is a transparent cover that provides convenient visual inspection. If the cover is removed, a patented cover-tamper trouble signal gives a 7-minute delay before the panel or remote accessory is notified of trouble. At a remote location, the remote test station option ensures that a detector is functioning properly and the remote sounder/LED indicator option signals if a detector is inalarm. However, the cover does not need to be removed if a detector needs to be reset at the detector. Simply push the built-in reset button. Innovp Xrr Features Photoelectric, low-flow technology An air velocity rating from 100 feet per minute to 4,000 feet per minute (.5 meters per second to 2032 meters per second) - Patented interconnectability for multi-fan shutdown - Two DPDT Form-C relay contacts 24 VACIDC or 120/240 VAC Versatile mounting options - Outside mounting tabs A patented telescopic sampling tube - Modular construction A patented cover-tamper trouble signal A transparent cover A remote test station Remote sounder/LED indicator options A built-in reset button 11 Agency Listings WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors,. NOT a substitute for early warning detection YL and NOT a replacement for a building's regular fire detection system. Refer to NFPA 72 and 90A for additional information. LISTED RA400Z Remote Annunciator (UL S2522) 551(451 Multi-Signaling Accessory (UL 268A) shown with PS241DW add-on strobe (P512/24SLENSW smoke lens option available) Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations, and several different means of visible and audible system annunciation. As with our duct detectors, all duct smoke detector accessories are UL listed. -; r . £ -- :-- APA45I RTS45IKEY PA400W R15451 Piezo Annunciator Remote Test Station Mini-Alert Sounder Remote Test Station (UL S401 1) with Key (UL 52522) (UL 53593) (UL 52522) shown with PS24LOW add-on strobe (PSI 24SLENSW smoke lens option available) -. - i _ :'; I • '. 4 - :::::::::: 43 551(451 ( • Multi-Signaling ------ik4;- Accessory'(UL 2613A) Ii - Information DH100ACDCLP 4-wire photoelectric duct detector with low-flow technology A5190 Replacethent 4-wire photoelectric detectdr board A5064 Replacement 4-wire power board Accessories 51-15 Metal sampling tube duct widths l-2'(03-0.6 m) MOD400R Sensitivity test module 51-3 Metal sampling tube duct widths 2-4'(0.6-1.2 m) RA400Z Remote annunciator alarm LED 51-5 Metal sampling tube duct widths 4-8'(1.2-2A m) F36-09-11 Replacement air filters (two per package) 51-10 Metal sampling tube duct widths 8'-12'(2.4-3.7 m) M02-04-00 . Test magnet - 180-71-00 Replacement telescoping sampling tube P48-21-00 End cap fbr metal sampling tubes P48-55-00 Replacement end cap forT80-71-00 508-39-01 Photo replacement sch 551(451 Multi-Signaling accessory PA400W Mini-Alert sounder' RT5451 KEY Remote test station with key lock P52410W Mini-Alert add-on strobe R15451 Remote test station PS12/24SLENSW Wall-mount'SMOKEiens APM51 Remote annunciator with piezo alarm P512/24SLENSC Ceiling-mount 5MOKEiens 3825 Ohio Avenue. St. Cha C2l65temSmo Charles, IL 60174 4 SEP.ISOR Phone: 800-SENSOR2. Fax 630-377-6495 A05-104'007-7156-11676 Innovair Duct Smoke Detector The air duct smoke detector shall be a System Sensor Model DH100ACDCIP Series Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0.5 to 2032 mlsec).The unit shall be capable of controlling up to ten (10) air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal In the event that the front cover is removed. It shall be capable of local testing via magnetic switch or remote testing using the 551(451 Multi - Signaling Accessory or the RTS451 KEY Remote Test Station The unit shall be reset by local reset button or remote test station. The duct smoke detector housing shall incorporate an airtight smoke chamber in compliance with UL 268A, Standard for Smoke Detectors for Duct Applications.The housing shall be capable of mounting to either rectangular or round ducts without adapter brackets. An integral filter system shall be included to reduce dust and residue effects on detector and housing, thereby reducing maintenance and servicing. Sampling tubes shall either be telescoping or be easily Installed by passing through the duct housing after the housing is mOunted to the duct. The unit shall provide a spacial separation of no less than V4'(6.4 mm) and/or a physical barrier between the high and low voltage terminals.The enclosure shall meet all applicable NECand NFPA-standards regarding electrical junction boxes. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size 143h'(37 cm) Length; 5½(14cm.) Width; 2W(7 cm.) Depth Shipping Weight 33A lbs. (1.7 kg.) Operating Temperature Range 32° to 131°F (0° to 55°C) Storage Temperature Range -22° to +158°F (-30° to +70°C) Operating Humidity Range 1096 to 93% relative humidity non-condensing Air Duct Velocity 100 to 4000 ft/min. (0.5 to 20.32 rn/sec.) 'intrna Power supply voltage 20-29VDC 24VAC 50-60 Hz 120 VAC 50-60 Hz 220/240 VAC 50-60 Hz Input capacitance: 270 p max. 270 p max. WA N/A Reset voltage: 3.OVDC mm. 2.OVAC mm. 1OVAC mm. 20VAC mm. Reset time (with RTS451): .03 to 0.3 sec .03 to 0.3 sec. .03 to 0.3 sec. .03 to 03 sec. Reset time (by power down): 0.6 sec max. 0.6 sec. max. 0.6 sec. max. 0.6 sec max. Power up time: - 34 sec max. 34 sec max. 34 sec. max. 34 sec. max. Alarm response time: 2t017sec 2t017'sec. 2t017sec. 2t017sec. SensitivityTest See detector label See detector label See detector label See detector label Current Requirements (Using No Accessories) Max. standby current 15 mA 35 mA RMS 25 mA RMS 15 mA RMS' Max. alarm current 70 mA 125 mA RMS 35 mA RMS' 25 mA RMS Contact Ratings Alarm Initiation contacts (SPST) 2.OA @30 VAC/DC (0.6 power factor) Alarm auxiliary contacts (DPDT) bA @30 VDC 1OA@ 250 VAC Note: Alarm auxiliary contacts must switch lOOmA minimum at SVDC. Alarm auxiliary contacts shall not be connected to initiating circuits of control panels. Use the alarm initiation contact for this purpose. Trouble contacts (SPOT) 2.OA @30 VDC (resistive); 2.OA @125 VAC (resistive) Accessory Current Loads at 24 VDC Device Standby Trouble Alarm APA451 12.5 mA Max. rVa 30 mA Max. PA400 0 m n/a 15 mA Max.. RA400Z 0 m n/a lOmAMax. RTS451/RTS451KEY -- 12 mA' n/a 7.5 mA Max. 551(451 5 mA Max 9 mA Max. 30 mA Max. 'Note: When a unit Is powered at the 120 VAC input, any combination of accessories may be used such that the given accessory loads are: 60 mA or less in the standby state; 110 mA or less in the alarm state. kO5-lO447 Wiring Guide System wiling diagram for 4-wire duct smoke detectors AVAILABLE POWER INPUTS . I AVAILABLE POWER INPUTS ACCEPT I CONNECT POWER SOURCE S 10 A B C I TO APPROPRIATE TERMINALS 24V0C.S4VAC oo.eoi e to A B C I OF EACH DETECTOR. SEE 15) VAC 50.60 HZ. OR SPECIFICATIONS FOR BLOSHOVACSOenHL j I i INFORMATION ADDI1TONALPOWER SUFFIX CONNECT POWER SOURCE 10 APPROPRIATE TERMINALS L24J Ll,~ oJ I L24JOF EACH DETECTOR. C I AC 2soa40_J I 5)01240.,J I I VAC I VAC I . ALARM AUXILIARY CONTACTS I ALARM AUXILURY CONTACTS FOR FAN SHUTDOWN. ETC. I FOR FAN SHUTDOWN, ETC. ALOO5flTRTP8 is 6 17 7 IS 6 is 6 17 7 15 B 10A 250 VAC FOR WIRING OF AUXIUARY lOOmAlANIMUM 0 5VDC DEVICES. REFER 10 N3 0. t—?.C. NOT INTENDED FOR MANUFACTURER'S CONNECTION 70 CONTROL INSTALLATION INSTRUCTIONS ED- PANELS. OR CONTACT MANUFACTURER I ALARM AUTOUARYCONTACTS SHOWN IN I ALARM AUXTUARY CONTACTS 5NOV54 IN N0125 SHE SUPERVISORY RELAY NOW I STANDBY. CONTACTS TRANSFER DURING I STANDBY. CONTACTS TRANSFER DURING PROVIDES APORMCCONTACTFOR ALARM AS INDICATED DY THE ARROWS, ALARM AS INDICATED EY THE ARROWS. I CUETOMIZEDAPPUCA1IONS. FOR STANDARD APPLICATIONS. ONLY UISS C5ITACTRAT1en I SUPERVISORY TROUBLE CONTACTS I SUPERVISORY TROUBLE CONTACTS 10.6 'NO' CONTACT IS USED 25AC5)yDCmduuve 2.0A0 125 VAC I _ I cnor*sweortscmnPcaeePov,sse I IWNEODIITACTEOcWDNAIAMINI080IenY. I IRVW%W0li WNW TMeeRFEAnJ6E TIMES OUT. OWi OWITACTSSIGN.LIESISIOmON1ORAIEI_ I ALARM ALARM CONTACTSSHOWN ALARM CONTACTS SHOWN - 5 5 INITIATION IMlIAlTON OPEN IN STANDBY. INITIATION '. OPEN IN STANDBY. LOOP CONTACTS \ CONTACTS CLOSE CONTACTS CONTACTS CLOSE INALARM. INALARI,L 1 L --------------- - UL LISTED E1ED 4-WIRE FIRST DETECTOR THE LOOP LAST DETECTOR IN TIE RESISTOR E LOOP SPECIFIED BY CONTROL PANEL DH100ACDCLP DHIOOACDCS.P PANEL MANUFACTURER Wiring diagrams for optional accessories: Wiring diagram for DH100ACDCLP to APM51: Wiring diagram forthe DH100ACDCLP to RT5451/R15451 KEY: DH100AcOCLP APM5I Alarm Signal 6j Alann DHIOOACDCLP RT845IIRTSASIKEY (Red LED) sans Signal (j) (Red LED) Alami Sup. N. 0. IthOId• I Sup. COM Power AuxPower+ &0--------* I Sup. N. 0. ceeainj penal. ro 'It-_(jj : . COM "t__(J (Green LED) (Green LED) Pewur Aux.Power - Common NOTE: Wiring diagram Shown IS for DH100ACDCLP "re duct Re,et smoke detector system equipped without a control panel. L NOTE: A trolide condition Is Indicated when the green LEO ® Is not illuminated. Teat Wiring diagram for DH100ACDCLP to 55K451: *NOTE: For RTS451KEY only without a Control FIELDaISTALLEO Panel, JUMPER FOR ITBIALPATtEWI RTS451 does not have a terminal 6, NOTE: Wiring diagram shown is for DH100ACDCLP 6511451 01tBJAOtSEP COI 3 I 4-wire duct smoke detector system ALUIMSIINN& 0- I -O •Ame iu. equipped without a control panel. I 65POWSOWeM. SUPEFASORY I NOTE: A trouble condition is indicated when the (am cwrmr RESET 0 I J (f) RESET green LED is not Illuminated. TEST ® I I.©TEST POWER AUX. POWER I-) I POWER 1.1 ® I I 0 AttN POSER I.) I FIELOIISTAUEO MipER ALARM SIGNAL (.) AUX POWER DUCT DETECTOR PM (OPTIONAL) DHIOOACDCLP AUDIBLE ALERT I ALARM StGNAL1 ::: D MIX POWER : DUCT DETECTOR OHIOOACOCLP Important Interconnect Notes When using the interconnect feature, all interconnected units must be powered with the same, independent supply. Polarity must be maintained throughout the interconnect wiring. Connect terminal 12 on unit ito terminal 12 on unit 2 and so on. Similarly, connect terminal ion unit 1 t terminal I on unit 2 and so on. Up to 10 units may be Interconnected. 545-1044-607 CALIFORNIA DEPARTh4ENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-1653:119 Page 1 of 2 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Duct smoke detector units, Models DHIOOP, DHIOOLP, DH100ACDCP, DH100ACDCLP, DH 100ACDCLPX, OH 100ACDCLWP, EDHI OOLP, EDH IOOACDCLP, OH IOOACDCI, DH200P, DH200PL, DH200RP, DH200RPL, DH400, DH400ACDC, DH400ACDCP, DH400ACDCPX, DH400ACDClR, DH400ACDCP5V, DH400ACDCI5V, DH400ACDCIHT, DH400REL, DH500, OH500ACDC, P270-10001 and P270-I000P. Unit consiêts of a housing, relay, electrical components, sampling and exhaust tubes and a listed detector head. Series DH400, P270-1001 and P270-I000P are intended for use with Models 1451DH (CSFM Listing No. 7271-1653:108) and 2451 (CSFM Listing No. 7272-1653:112) detector heads for open area protection which have been tested for duct applications. Model DH400ACDCIHT is intended for use with Model I45IDHHT smoke detector (CSFM Listing No. 7271-1653:108) Series DH500 are intended for use with Models 1551 (CSFM Listing No. 7271-1653:105) and 2551 (CSFM Listing No. 7272-1653:106) detector heads for open areas that have been tested for duct applications. *Model DHIOOACDCLWP has a NEMA 4 watertight housing that is to be installed where the ambient air temperature will not fall outside the range of 32 degrees Fahrenheit to 131 degrees Fahrenheit. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Model DH400ACDCIHT may be used with model bH4000E-1 (Hoffman Model A-18R126) enclosure for outdoor application. MARKING: - Listee's name, model designation, air velocity rating and UL label. Page 2 of 2 3240-1653:119 APPROVAL: Listed as duct detector units when used with listee's separately listed compatible fire alarm control units. Models DH 100LP, EDH 100LP, DH IOOACDCLP, OH 100ACDCLPX, DH 100ACDCLWP, DH200PL, DH200RPL and EDHI OOACDCLP are suitable for use in ducts where air velocity varies between 100 and 4000 fpm. Models P270-10001 and P270-1000P are suitable for use in ducts where air velocity varies between 300 and 4000 fpm. Models DHIOOP, DH100ACDCP, DHIOOACDCI, DH200P, DH200RP, 0H400, DH400ACDC, DH400ACDCIR, DH400ACDCP5V, DH400ACDCI5V, DH400ACDCIHT, DH400REL, DH500, and DH500ACDC are suitable for use in ducts where air velocity varies between 500 and 4000 fpm. Also suitable for use as a-stand-alone unit where permitted. NOTE: Formerly 3240-1209:137, 139 and 3240-1209:155 *Rev 7-09-2007 mt This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an Independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or Installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires Juneb, 2009 Authorized By: BEN HO, Chief Fire Engineering Division COOPER Notification Weatherproof Appliances -Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories FZ _ iIH a Aftii Description: Designed for lire safety, performance and reliability, Cooper Wheelock's cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes RSSWP Horn Strobes ASWP Horns AH-24WP AH-1 2WP Multitone Horn Strobes MTWP Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-40°C to 660C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper-Wheelock provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the* Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. @--=A 11 <~> NIKA APPROVED E5946 151-92-E 7125-0785:131 (ASWP) 55391 7125.0785:146 (ET70WP) S2852 7125.0785:156 (MTWP) 7300-0785:154 (RSSWP) All models may be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized white the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Features: Approvals include: UL Standards 1971, 1638,464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP). See agency approvals by model number on page two of this document Compliance with the following requirements: NFPA, UFC, ANSI 117. 1, OSHA Part 29, 1910.165, ADA Weatherproof With extended temperature range of —40°F to 150°F (-40°C to 66C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Models with field selectable tone, dBA and candela settings Wall or ceiling mounting opt Surface of semi-flush mohiing IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal The series RSSWP, ASWP, MTWP and ET70WP have UL approval down to 40F. The AH-24WP MT-12124 and the ET-1 010 have been ULC tested and approved to -40°F, but not submitted to UL. The AH-.I2WP has UL!ULC approval to -31°F. NOTE: All CAUTIONS and WARNINGS are Identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFU L L Y B E F O R E U S I N G , S P E C I F Y I N G O R APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS.' FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMP R O P E R A P P L I C A T I O N , I N S T A L L A T I O N A N D I O R OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND S E R I O U S I N J U R Y O R D E A T H T O Y O U ANDIOR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe Intensity based on UL Standards 1971 and 1638 as i n d i c a t e d I n c a n d e l a r a t i n g s t a b l e . Wall Mount Ceiling Mount Wall or Ceiling Mount _ iIr _ RSSWP M1WP RSSWP MW _P . MT AN ASWP ETTOWP ASWP E17OWP ET.1010 Strobe Order Code Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 Audible Order Code RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 AH-24WP-R Red 7416 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 AH-12WP-R Red 7415 RSSWP-24MCWH-FW White 5165 RSSWP-24MCCH-FWVVhite 5187 Speaker Strobe ET70WP-2475W-FR Red E170WP-2475W-FW White ET70WP-24185W-FR Red ET70WP-24185W-FW White ET70WP-24135W-FR Red ET70WP-24135W-FW White Audible Strobe Red 9012 ASWP-2475C-FR Red 4251 Red 5137 ASWP-2475C-FW White 4502 White 5140 ASWP-24MCCH-FR Red 5149 ASWP-24MCCH-FW White 5157 Red White Red White 8420 Multi-tone Strobe 3112 MTWP-2475C-FR Red 5132 MTWP-2475C-FW White 5134 MTWP-24MCCH-FR Red MTWP-24MCCH-FW White 9077 Speaker Strobe 3179 ET70WP-2475C-FR Red 4885 ET70WP-2475C-FW White 4891 ET70WP-24177C-FR Red 4872 ET70WP-24177C-FW White 4875 ET70WP-24115C-FR Red ET70WP-24115C-FW White Horn MT-12124-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 IL Max. Current AH 24VDC I2VDC High (99) dBA 0.080 0.192 Ied(95) dBA 0.043 0.108 .0w (90) dBA 0.021 0.058 JL Reverberant dBA © 10 Feet watts 1/8 1/4 1/2 1 2 4 j] ET-11010 77 80 83 86 87 92 94j] T70WP 78 81 84 187 190193 i5j] Audible Strobe ASWP-2475W-FR ASWP-24MCHH-FR ASWP-24MCWH-FW Multi-tone Strobe MTWP-2475W-FR MTWP-2475W-FW MTWP-24MCWH-FR MTWP-24MCWH-FW 4457 4478 5102 5122 4452 4454 4845 4859 4550 4732 Candela Ratings Series UL 1971 U11638 @ 77 U11638 © -40E RSS, ET70WP and MTWP UL Max Current (Strobe Only) ASWP _____ High Mad Low 2475 30** 180 115 0.138 0.168 0.155 0.150 MCWH 135 135 Be 0.300 0.355 0.340 0.335 185 185 1 77 0.420 0.480 0.465 0.460 MCCH 115 115 47 0.300 0.355 0.340 0.335 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 awfl mount rating only 24177 177 177 73 0.420 IL Max. Current Audible) MTWP/MT 24 VOC MT 12 VDC BA Hi STD HI STD lorn 0.108 0.044 0.177 0.034 elI 0.053 0.024 0.095 0.020 larch Time 0.104 0.038 0.142 0.034 ode 3 Horn 0.091 0.035 0.142 0.034 ode 3 Tone 0.075 0.035 0.105 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Iran 0.104 0.036 0.152 0.030 HI/Lo 0.057 0.025 0.114 0.026 Model Number Agency Approvals Strobe UL MEA CSFM FM UP RSSWP-2475 X X X X * RSSWP-24M CWH X * X * * RSSWP-24MCCH X * X * * Audible Strobe ASWP-2475 X X X X X ASWP-MCWH X * X * * ASWP-MCCH. X * X * Multltone Strobe MTVJP-2475 X X X X * M1WP-MCWH X * X * MTWP-MCCH X * X * * rnslAudlbies H-24WP X X X - X H-12WP X I X X - X MT-12/24 X X X X X peaker Strobe ET70WP-2475 X X X * ET70WP-185 x X * * ET70WP-177 x a a * T70WP-115 x x a a ET70WP-135 X * a * *pending Mounting Accessories WFP WFPA Gasket Kit Order Code WP-KIT 4486 Flush Plates WFPA-R Red 4698 WFPA-W White 4701 WFP-R Red 4696 WFP-W White 4697 Backboxes lOB-R Red 5046 lOB-W White 5047 WPSBB-R Red 9751 WPSBB-W White 3033 WPBB-R Red 9014 WPBB-W White 4692 WBB-R Red 2959 WBB-W White 2960 lOB WPSBB WPBB WBB Mounting Options: Backboxes, Plates, Gasket Kits Surface Mount Flush Mount Exposed Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB + WP-KIT WFP ET70WP Speaker Strobes lOB lOB + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-XlT WFPA AHWP Horns WBB - WFP ET-1010 Speakers WBB - WFP MT\NP Multitone Horn Strobes lOB lOB + WP-KIT WFP Multitone Horn . lOB lOB + WP-KIT WFP Wiring Diagrams SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON RED AND BLACK SHUNT-WIRES ARE SUPPLIED. LIJU TO NEXTO CEDINGO +0— REI APPLIANCED FACPO I -0 nv —DOR EOLRO STROBSD AUDXBLEO SERIES RSSWP,ASWP,AHWP, MflNP AND MT-12124 APPLIANCES +0 FROMO TO NEXTO PRECEDINGE3 APPLIANCE ORD _0APPLIANCEE FACeD __________ OR EORO SERIES M1WP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP NTWPO 'Strobe rcui Hodule0 1 OrD 'ote PowerO supply0 FACeD HAC l#2 Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED WI DSM MODULE SINGLE CLASS '1A" NAC CIRCUIT STROBED NACU SYNCO - CIRCUITC] I OUTO 10+OZJT1O [i r+O+ IN 10 E1NU8 10 FAC ,MINUS 20 ( )+Iw2o I WACO CIRCUITO RETURNO Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet 87000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In ac c o r d a n c e with Wheelock Inc. standard terms and conditions. Cooper Notification is Wheelock' (MEDC) ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box In walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon tlashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 Cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 od at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervislorl of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series E170WR They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM, DSM Sync Modules, Wheelock Power-Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation.. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA 59004 WP 05/08 . CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE &I LISTING No. 7300-0785:154 Page 1 Of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models RSSWP-2475W and.RSSWP-2475C synchronous or non-synchronous strobe light. Model may be followed by two alpha or numeric characters indicating lettering and color, followed by W for wall mount or C for ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. Models RSSWP-24MCWH (wall mount) & RSSWP-24MCCH (ceiling mount) audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. RATING: Electrical: 16-33 VDC/VFWR Flash rate: 60 flashes/mm. Candela: RSSWP-2475W RSSWP-2475C RSSWP-24MCWH RSSWP-24MCCH 30cd(l15cdat-40C) 30cd (ll5cd at-40 C) Selectable 135/185cd (65/90cd at -40 C) Selectable 115/177cd (50/75cd at -40 C) INSTALLATION: In accordance with listee's printed installation Instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model can be used outdoors when used with WPSBB back box only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a strobe light for use with separately listed electrically compatible fire alarm control units. For indoor or outdoor use. Intended for wall mount or ceiling mount. Lens color may be white, red, blue, green or amber. For synchronized strobes, Models SM-12124, SMX-12/24 Sync Modules, DSM-12/24 or DSMX-12/24 Duel Sync Modules (CSFM Listing No. 7300-0.785:1323) or power supply PS- 12/24-8 (CSFM Listing No. 7315-0785:149) must be used. , Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ';' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Series AS Audible Strobe Appliances and Series AH Audibles :J. _ SERIES AS SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 15750d or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 151301751110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30175/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADNNFPNUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15130/75/95cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce I flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWO wires For Weatherproof Series AS, See Datasheet S9004 MEA APPROVED E5948 151.92.E 7125-0785:131 55391 24 VDC Models High (99) 24 vdc dBA UL Mae Mad (95) 24 vdc dBA UL max* Low (90) F ULmax*dBA 12 VDC Models AH-24 AS-241576W 1575cd 0.062 0.100 0.080 0.121 0.033 0.080 0.043 0.107 0.017 0.072 0.021 0.100 Audible Wall Mount Audible Strobe AH-12 I A3421575W High (99) 12 vdc 0.163 0.260 UL max* 0.192 0.320 dBA Mad (95) 12 vdc 0.076 0.195 UL max* 0.108 0.275 dBA Low (90) 12 vdc 1 0.039 0.175 UL max* 0.058 0.265 dBA NOTE: MI CAUTIONS and WARNINGS are Identified by the symbol A. All warnings are printed In bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING This PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU ANDIOR OTHERS. General Notes: Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range". Note that NFPA-72 specifies a flash rate oil to flashes per second and ADA Guidelines specify a flash rate of Ito 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" Is the newest terminology used by UL to Identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCWH 24 16.0 -33.0 135/185 ASWP-2475W 24 16.0-33.0 j 75 @ -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 464 dBA @10 ft. @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Code 3 Horn Medium 84 95 Low 79 90 Table 3: Average RMS Current I Audible I Wall Mount Audible Strobe Models Coiling Mount Audible Strobe Models AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 0.080 0.102 0.160 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 0.060 0.084 0.132 0.173 1 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 0.088 0.105 0.182 0.245 0.335 0.460 1 0.074 0.113 0.198 0.263 0.335 0.480 Table 4: Average Current* (AMPS) For Series ASWPH Voltage High dBA Setting (99) dBA Medium dBA Setting (95) dBA Low dBA Setting (90) dBA 24.0 VDC 0.128 0.105 0.098 1 UL Max* 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibies the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams* I SERIES AS APPLIANCES NON-SYNCHRONIZED FROMD TO NEXTO PRECEDINGD PPLIANCED APPLIANCED OR EOLRO OR FACPD SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP and PS-12124-SMP :l:IeEo FD -OsTRODED A StobC NAM L ! Circut 4eudib PC]EOLRO kudibleD -A,dib .0 NACO CircuitO SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM OUTPUTSO ROLSO MODULES FO 1-40 4-CLRSSO #10 Audible NIC M AD "ro co opa 2-CLMSO IStrobe MAC AS OF i:i__ 1'i FU PO IPOU Audible MAC SM 020 AOl IStrobe MAC Tr yn AS AS [i Series P5-12/24-8 I co SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE P0 IStrobe MAC DSM Interconnecting wiring shown. Maximum twenty (20)0 0For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM.. For wiring informationon the power supplies refer to Installation instructions P84662 for PS-24-8MC. Specifications and Ordering Information Model Number Order Code Strobe Candela Non- Sync Sync w!SM, DSM or PS-24-BMC 24 VDC 12 VDC Wall Mount Ceiling Mount Mounting Options***- Agency Approvals UL -- MEACSFMFMBFP - - - S-24MCW-FR 9024 151301751110 X X X - X - A,B,D,E,F.G,H,J,N,O,R,X X X X X I X S-24MCW-FW 9025 1 15/30/75/110 X I X X - X - A,BD,E,F,G,H,J,N,O,R,X X X X X X AS-24MCWH-FR 3468 135/185 X X X - X - A,B,D,E,F,G,H,J,N,OR,X X X X. X * S-24MCWH-FW 3469 135/185 X X X - X - A,BID,EIF,GIH,J,N,O,R,X X X X X * AS-241575W-FR 7405 15 (75 on Axis) X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X AS-121575W-FR 7410 15 (75 on Axis) X X X X AB,D,E,F,G,H,J,N,O,R,X X X X X X AS-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,DIE,F,G,H,J,N,O,R,X X X X X * S-24MCC-FW 3162 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,NO,RX X X X IX * AS-24MCCH-FW 3467 115/177 X X X - X A,B,D,E,FG,H,,O,R,X X X X IX * ASWP2475W.FR** 9012 75 @ -31°F X X X - X - I (see Data Stet S9004) X X X I X X AH-24-R 7892 - X X X - X X AB,D,E,F,G,H,J,N,O,R,X X X X JX . X AH-24-W 7893 - X X X - X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X H-12-R 7891 - X X - X X X A,BID,E,F,G,H,J,N,O,R,X X X X X X AI-f-12-W 17894 - X X - X X X A,B,D,E,F,GI-1,J,N,O,R,X X X X X X AH24WPR** 7416 - X X X - X X K X I X X X H12WPR** 174151 - X X - X X X K X X -i-1- X For Weatherproof Series ASIAH specifications see data sheet S9004. TENDING ***Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. S8100 ASIAH 10/07 Cooper Notification Is Wheelock (MI1D() Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The SeriesAS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for CIBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1.971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575,-241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color.. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W, and *Aswp..24750 audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *Aswp..24McwH and *ASWP24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd M•CW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd (65cd, 90cd at -40 C) MCCH: Selectable 1l5cd, 177cd (50cd, 75cd at -40 C) Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP- 24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix - W or WH are for wall mount only. Models with suffix -c or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *Aswp..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12124, DSM-12/24 or DSMX-12124 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. NOTE: These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Models AH-12, AH-24, -I2WP and -24WP audible devices are not suitable for the hearing impaired applications. 1~ J Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing Is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division Unshielded Multi-conductor FPLR/CMG FT4 Rated Product Description Bare copper conductors, PVC insulation, conductors cabled together, Red PVC jacket with rip cord. Sequential footage marking every two feet. Color Code: See chart below. Specifications - Conductor Bare Copper Insulation PVC Jacket PVC Jacket Thickness .015' (.381 mm) Approvals NEC FPLR CEC (22-16 AWG only) CMG Ff4 California State Are Marshall NEC Articles 760 Voltage Rating 300V Temperature Rating 75°C Applications Are Pmtectior Alarm -Signal Monitor/Detection Audio Circuits - Control Circuits Initiating Circuits Notification Circuits Color Code Chart 1 I1lu1It'MrIIl'1'llhl Black 2 Red Brown 4 Blue 5. . Orange S Yellow 7 Purple B Green B Red/Black 10 Red/White - 11 Red/Green 12 Red/Blue NEW GENERATIONS CABLES 13.35 Fire Alarm Cable Commercial Applications Power-Limited Sa_)A!a)) NEW GENERATION' Unshielded Multi-conductor (NEC FPLR and CEC CMG Ff4) . . 5522111 4 solid 11-1000 (1-305 16.0 7.3 .010 .25 .125 3.18 1000 305 16.0 7.3 5524111 6 solid (1-1000 11-305 22.0 10.0 .010 .25 .168 4.27 am 1000 305 22.0 10.0 5526111 8 solid (1-1000 (1-305 28.0 12.7 .010 .25 .182 4.62 1000 305 28.0 12.7, 5320111. 2 solid (1-5.00 11-152- 8.5 3.9 .010 .25 .151 3.84 500 152 8.5 3.9 11-1000. U-305 17.0 7.7 1000 305 . 17.0 7.7 5322(11 4 solid (1-500 (1-152 15.5 7.0 .010 .25 .176 4.47 500 . 152 15.0 .6.8 - . LJ-11100.,..U7305....30.0 13.6......... . ........ .... 1000 305 30.0 13.6 - 5324111 6 solid 500 152 23.5 10.7 .010 .25 .212 5.38 U-boo U-305 43.0 19.5 1000 305 45.0 20.5 . . 5326111 8 solid 500 . 152 31.0 14.1 .010 .25 230 5.84 1OJJO 305 61.0 27.7 532811I. .10 solid . 1000 305 71.0 32.3 .010 .25 272 6.91 5329(11. 12 solid . 1000 305 83.0 37.7 . .010 .25 281 7.14 MAIN I 5220(11 2 solid (1-500 11-152 13.0 5.9 .010 .25 .174 4.42 • 500 152. 13.0 5.9 (1-1000 (1-305 24.0 10.9- 1000 . 305 25.0 11.4 . j. 5222111 .4 solid 1000 305 45.0 20.5 .010 .25 .201 5.11 5120111. 2 solid : 500 152 19.0 8.6 .013. .33 .213 5.41 ii 1000 305 38.0.17.3 . II 51220L 4 solid 500 152 35.0 15.9 .013 .33 .251 6.38 1000 305 70.0 31.8 - . Li 5020(11 2 sbtid 1000 305 59.0 26.8 .013 .33 .244 6.20 I RRIAH'. - CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-0060:103 Page 1 of I CATEGORY: Cables-Fire Protective Signaling LISTEE: Belden Wire & Cable Co., P.O. Box 1980, Richmond IN 47375-1980 Contact: Gerald Lee Dorna (765) 983-5200 Fax *(775) 805-2991 DESIGN: Type FPLR power-limited fire protective signaling cable. Refer to listee's data sheet for detailed product description and operational considerations. Insulation: Semi-rigid PVC compound No. 70 through X79, X960 through X979, X2000 through X2049 or X-20 through X-39, X2400 through X241-9, X-6501 through X-6539, or Gaon 8891. Shields: (Optional) metal or polyethylene terephthalate/metal tape shield. Core Wrap: (Optional) Glass Reinforced TFE (Teflon) impregnated tape or polyethylene terephthalate. Filler: (Optional) PVC or polypropylene. Jacket: PVC Compound No. X-99000 through X-99199 or X-199000 through X-199199. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type, classification and UL label. APPROVAL: Listed as power-limited fire protective signaling cable. L v. 03-20-06 IP .1 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or V. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 11 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager 10/02/2008 09:27 7144499692 SSD SYSTEMS INC PAGE 01 72-25 FUNDAMENTALS OF FIRE ALARM SYSTEMS Fire Alarm System Record of Completion Name of Protected Property RALPHS#175 -. Address: 7140 AVENIDA ENCINAS, CARLSBAD CA 92011 -- Rep. Of Protected Prop. (name/phone): Authority Having Jurisdiction: Address/Phone Number; I. Type(s) of System Service: NFPA 72, Chapter 6— Local If alarm is transmitted to location(s) off premise. list where received: SSD SYSTEMS 1740 N. LEMON STREET ANAHEIM, CA 92801 NFPA 72, Chaptcr 6— Emergency Voice/Alarm Service Quantity of speakers installed Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72. Chapter 9—Auxiliary Indicate type of connection: Local energy, ___ Shunt Parallel telephone Location and telephone numbcr for receipt of signals: -- NFPA 72, Chapter 8.- Remote Station Alarm! Supervisory: NFPA 72, ChapterS — Proprietary If alarms are retransmitted to public service communications center or others, indicate location and telephone number of the organization receiving alarm: Indicate how alarm is, ch w sin tted; NFPA 72, Chapter 8.-Central Station The Prime Contractor: SSD SYSTEMS Central Station Location: SSD SYSTEMS 1740 N LEMON STREET, ANAHEIM, CA 92801 Means of transmission of signals from the protected premise to the central station: McCulkih. Multiplex Onc-Way Radio - Digital Alarm Communicator Two,-Way Radio - Others Means of transmission of alarms to the public tire service communications center; - _TELCO TELCO Systcm Location: Organization Name/'hone Representative NamclPhonc Installer Supplier Service Organization Location of Record (As-Bum) Drawings: Location of Owners Manuals: Location of Test Reports: A Contract, dated • for test and inspection accordance with NFPA standard(s) No.(s) 72 ,dated 2002 is in cfl'cct. Figure 1-6.2.1 Certificate of Completion 2002 Edition 10/02/2008 09:27 7144499692 SSD SYSTEMS INC PAGE @2 72-26 NATIONAL FIRE ALARM CODE Record of System Installation (Fill out after installation is compicte and wiring checked for opens, shorts, ground faults, and improper branching, but Prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as listed below, was inspected by on X , includes the deces listed below and has been in service since X NFPA 72, Chapters 12 3 4 5 6 7 8 9 10 11 (circle all that apply) - - NFPA 70, National Electrical. Code, Article 760 'I Manufacturers Instructions Other (specify): Signed: X Date; X Organization; Certification of System Operations All operational features and functions of this systcm were tcstcd by C few (S - - on Pound to he operating properly in accordance with the requirements 01 NFPA 72.Chaptct 1234567 8910 11(circleall that apply) NFPA 70, National Electrical Code, Article 760 / Manufachrrer'S Instructions Other (specify): NONE Signed: X Organization: SSD SYSTEMS Alarm Initiating Devices and Circuits MANUAL Date: x /04/0 , T--7- and and 1 Manual Stations Noncoded. Activating 1 Transmitters Coded Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATJC Coverage; Complete; Partial: a) I Smoke Detectors - ion X Photo b) 2 Duct Detectors Ion - 2 Photo G) Hest Detectors FT RR FT/RR - RC 2 1 Sprinkler Water flow Switches Noncoded, activating 2 Transmitters Coded Other (list) (3) ANSI.JL SYSTEM 5. Supervisory Signal Initiating Devices and Circuits (Use blanks to indicated quantity of devices.) GUARD'S TOUR Coded Stations Noncoded Stations Activating Tranrnnttcrs Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations Note Combination devices recorded under 4(b) and 5(a). SPRINKLER SYSTEM 3 Coded valve supervisot/ signaling attachments Valve supervisniyswitchcs. activating 3 Transmitters Building temperature points C) Site water tcmpaturc points Sire water supply level points Electric Fire Pump; c) PiTa pump power Fire pump running g) - Phase reversal Etiginc. Driven Fire Pump: Selector in auto position 1) Engine or controller panel trouble 3) Fire pump running Engine— Driven Generator: k) - Selector in auto position 1) Control panel trouble M) Transfer switches n) ______ Engine running Figure 1.6.2.1 Record of Completion (continued) 2002 Edition 102/2008 09:27 7144499692 SSD SYSTEMS INC PAGE 03 72-27 FUNDAMENTAL OF FIRE ALARM SYSTEM Other Supervisory Function(s) (specify) Alarm Notification Appliances and Circuits Typcs and Quantity of alarm indicating appliances installcd: - c1Is Inch Speakers b) X Horns C) - Chimes d) Other: e X Visual SignaLs Type HORN/VISUAL - With audible Without audible f) Local Annunciator Signaling Line Circuits: Quantity and Style (See NFPA 72, Table 3-6) of signaling line circuits connected to system: Quantity: Style; System Power Supplies: PTimaly (Main) Over current Pjtjtvction: Nominal Voltage: 24 VAC Currect Rating: Type DEDICATED CIRCUIT Current Rating: IS AMP. 15 AMP Location: ELECTRICAL ROOM Secondary (Standby)- 2 Storage Eattcry. Amp Hour Rating: 12 A.H. - CalcuIattl capacity to drive system, in hours: '1 24 60 Engine - driven generator dedcated to fire alrrn qr. timi: C) Location of fuel storage Emergency or Standby System used as backup to primary Power Supply, instead of using aSecondmy Power Supply" -_- Emergency System described in NFPA 70, Article 700 Lcgally Required Standby System described in NFPA 70, Article 71 Optional Standby described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software Operating System Software Revision Level(s); Application Software Revision Level(s): Revision Completed by: (nsn) (6nn) 10. Comments (Signed) for Central Station of Alarm Service Company (title) (date) -. Frequency of routinc tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: -- (Signed) for Central Station of Alarm Service Company (title) (date) Upon completion of the system(s) satisfactory test(s) witnessed (if rcquircd by the authority having jurisdiction): x (Signed) representative of authority having jurisdiction (title) (date) Figure 1-6.2.1 Record of Completion 2002 Edition Class