HomeMy WebLinkAbout7140 AVENIDA ENCINAS; ; FS080003City of Carlsbad Fixed Systems Permit 7140 AVEN IDA Job Address: ENCINAS Permit Type: FIXSYS Parcel No: 2144302700 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 2/22/2008 Approved: 2/22/2008 Issued: 2/22/2008 Inspector:, Project Title: RALPHS #175 HOOD & DUCT PLAN CHECK & INSPECTION Applicant: ECHO FIRE PROTECTION I :kS :I.Xf:I 88-521-5752 Owner: RALPHS GROCERY CO 1100 W ARTESIA BLVD COMPTON CA Fees ($) Add'l Fees ($) Total ($) . Balance ($) . 130 0 130 0 fl R-102 RESTAURANT FIRE SUPPRESSION SYSTEM Design, Installation, Recharge and Maintenance Manua [tiANSUL. SECTION IV - SYSTEM DESIGN• UL EX. 3470 ULC CEx747 Page 4-1 4-1-06 REV.6 SYSTEM DESIGN The ANSUL R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a. current ANSUL certificate in an R-102 training. program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either. an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or. PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. Both systems must actuate simultaneously. Each system must be designed and installed per its apprOpri- ate manual. Adjacent appliances requiring protection must be protected With the same type of system, either R-102 or PIRANHA, unless the center-to-center spacing between the adjacent R-102 and PIRANHA flozzles is no less than 36 inches. When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. Mixing systems in a common plenum IS not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub-sections: Noz- zle Placement Requirements, Tank Quantity Requirements, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirementè. Each of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quantity and piping requirements. Duct Protection - Single Nozzle All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles. to the horizontal and ducts with directional. bends. The R-102 system uses different duct nozzles depending On the size of duct being protected. GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (5-20 cm) into the center of the duct opening, discharging up. See Figure 1. 2-8 IN. (5-20 cm) FIGURE 1 00cm In installatiOns where a UL. listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maximum, to a point just beyond the damper assem- bly that will not interfere with the damper. Exceeding the maxi- mum of 8 in. (20 cm) in this way will not void the UL listing of the system. .Previously listed 3 flow number and 5 flow number duct pro- tection detailed in earlier published manual, Part No. 418087- 06, can also still by utilized. F T SIZES UP 1050 IN. (127 cm) IMETER! 16 IN. (41cm) DIAMETER One1W nozzle (Part No. 41W36) = One flow number 50 in. (127 cm) perimeter maximum 16 in. (41 cm) diametei maximum . DUCT SIZES UP 10100 IN. .(254 cm) PERIMETER! 32 IN. (81.3 cm) DIAMETER One 2W Nozzle (Part No. 419337) = two flow numbers 100 in. (254 cm) perimeter maximum 32 in. (81.3 cm). diameter maximum A 2WH nozzle (Part No. 78078) must be substituted for a 2W nozzle for any installation using Option 2 of the 1.5 gallon sys- tem coverage (duct and plenum protection only). A 2WH nozzle is limited to a maximum of 75 in. (190 cm) perimeter or a maxi- mum diameter of 24 in(61 cm) of coverage. The chart below shows-the maximum protection available from each duct nozzle. Part,• 3.0 Gallon 1.5 Gallon Desôription . No... : :. System System 2W Nozzle 419337 Maximum Maximum 100 in. (254 cm) 100 in. (254 cm) Perimeter Perimeter ' 1W Nozzle 419336 Maximum 'Maximum 50 in. (127 cm) 50 in. (127 cm) Perimetef Perimeter FIGURE 11 FIGURE 14 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-6 REV. 5 4-1-06 Plenum Protection (Continued) HORIZONTAL PROTECTION - OPTION 2 For a plenum, either single or "Vp bank, with a linear extension 1W NOZZLE - PART NO. 419336— ASP BANK PROTECTION longer than 10 feet (3.1 m), each bank maybe protected using one IN nozzle every 10 ft. (3.1,'m) or less depending on the overall One 1W nozzle will protect 6 linear feet (1.8 m) of U5/A bank plenum. length of the plenum. See Figure 12. The nozzles may point in the The nozzle must be mounted horizontally, positioned 1/3 the filter opposite directions as long as the entire plenum area is protected, height down from the top of the filter. Nozzles can be located at 6 fL and the 10 ft. (3.1 m) limitation is not exceeded. See Figure 13. The 1 (1.8 m) spacings on longef plenums. The nozzle must be positioned nozzle positioning shown in Figure 14 is not an acceptable method 0-6 in. (0-15 cm) from the end of the hood to the tip of the nozzle. of protection because the plenum area directly under the tee Is not See Figure 10. within the discharge pattern of either nozzle. IWNOW.E 10Ft(3.1m) MAXIMUM '1 IOFT.(3.1 in) MAXIMUM 10 FT. (3.1 m) MAXIMUM FT. (9.1 m) FIGURE 12 10FT.(3.1 m) MAXIMUM FIGURE 10 MAXIMUM W FT. (31 MAXIMUM m) 42 1 NOZZLE - PART NO. 419335 - "Va BANK PROTECTION Two IN nozzles will protect 10 linear feet' (3.1 m) by 4 ft. (1.2 m) wide of 115f bank plenum. The nozzles must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-15 cm) from the end of the 'hood to the tip of the nozzle. See Figure 11. FIGURE 13 I FIGURE 8 HORIZONTAL PROTECTION - OPTION 1 1 NOZZLE - PART NO. 419335 - SINGLE BANK PROTECTION One IN nozzle will protect 10 linear feet (3.1 m) of single filter bank Plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6in. (0-15 cm) from the end of the hood to the tip of the I nozzle. See Figure 9. FIGURE 6 cm197 When protecting plenums with the 1W nozzle, two options of cov- I- erage are available: Option 1: The 1W nozzle must be On the center line of the single or 'V bank filter and positioned within 1-20 in. (2.5-51 cm) above the top edge of the filter. See Figure 7. FIGURE 9 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-5 4-1-06 REV.4 Plenum Protection. The R-102 system uses the 1W Nozzle (Part No. 419336) or the IN Nozzle (Part No. 419335) for plenum protection. The 1W noz- zle tip is stamped with 1W and the I nozzle tip is stamped with iN, indicating they are one-flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. VERTICAL PROTECTION - GENERAL One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft. (.6 m). After the first nozzle, any additional nozzles must be positioned at a:maximum of 4 ft. (1.2 m) apart down the entire length of the plenum. The plenum width must not exceed 4 ft. (1.2 m). (The 1W nozzle can be used on single or V-bank filter arrangements.) See Figure 6. Option 2: The 1W nozzle must be placed perpendicular, 8-12 in. (20-30 cm) from the face of the filter and angled to the center of the filter. The nozzle tip must be within 2 in. (5 cm) from the perpendicular center line of the filter. See Figure 8. 8 IN. (20 cm) MINIMUM NOZZLET1P MUST BE WITHIN THIS AREA 20 IN. (51 cm) MAXIMUM 1 IN. (2.6 cm) MINIMUM FIGURE 7 m0199 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-9 4-1-06 REV.8 Fryer -Single Nozzle Protection (Continued) Maximum Area Dimensions - Single Nozzle Fryer Protection (Continued) Max. Size Max. Size Overall Type of Nozzle Height Frypot Only With Dripboard Nozzle Above Top of Fryer 19.5 in. x19 in. 19.5 in. x253/8 in. 290 13 in. to 16 in. (50 cm 48 cm) (50 cm x 65 cm) (33 to 41 cm) 19.5 in.x 19 in. 19.5 in. x 25 318 in. 3N See Figure (50 cm x 48 cm) (50 cm x 65 cm) 18 18 in. x 18 in. 18 in.x 273/4 in. 3N 25 in. to 35 in (46 cm x 46 cm) (46 cm x 70.5 cm) (64 cm to 89 cm) Nozzle Location See Figure 17 See Figure 18 See Figure 19 11 ,1 FRYER WITHOUT DRIPBARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA ± 3 IN. (7.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND ±1 IN. (2.5 a FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND 00M10 CENTERUNE AIMED AT THE MIDPOINT OF THE COOKING AREA. FRYER WIThOUT DRIPBOARD FRYER WITH DRIPBOARD FIGURE 17 NOTE: SN NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER. FIGURE 19 34 IN. (86 cm) MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD SN NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOK- ING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 18 Range Protection 2-FloW Nozzle High Proximity Application (2-Flow Nozzle): 40 in. to 50 in. (102 cm to 127 cm) above the cooking surface. This high proximity application uses the 245 nozzle, Part No. 419340. The nozzle tip is stamped with 245 indicating this is a two-flow nozzle and must be counted as two flow numbers. One 245 nozzle will protect a maximum cooking area of 672 sq. In. LOCA TI COOKING SURFACE o ) (4335 sq. cm) with a maximum longest dimension of 28 in. (71 cm). When using this nozzle for range protection, the nozzle must OR ii 3/8 IN. (29 cm) be pointed vertically down and positioned as shown In Figures CENTERLINE OF NOZZLE 29 and 30. TO CENTER OF ANY 101 BURNER GRATE ING 245 NOZZLETIP LOCATION CENTER OF) COOKING SURFACE OR 1138 IN. (29 cm) MAXIMUM FROM CENTERLINE OF NOZZLE TO CENTER OF ANY BURNER GRATE SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-14 REV.5 10-1-02. 245 NOZZLE TIP LOCATION CENTERLINE OF COOKING SURFACE 501. I lIr 02. —.1 MAXIMUM I HEIGHT I OF 245 - NOZZLE -lip 40 IN. 1 (102 an) MINIMUM HEIGHT I 0F245 I NOZZLE TIP I I— 00236 0 00 0 0 I FIGURE 29 NOTICE Four burner grates shown in Figure 30. For sin- gle or double burner grates, locate nozzle at center of cooking surface or 113/8 in. (29 cm) maximum from nozzle centerline to center of any burner grate. FIGURE 30 - AIM POINT (DIAGONAL CENTER OF CENTER OF MODULE I Ij I MODULE COOKING AREA) COOKING i IMIO IN T (DIAGONAL N AREA) I J RIGHT-TO-I.EFT RIGH1TO- CENTERUNE LEFT - CENTER- LINE SECTION IV - SYSTEM DESIGN UL EX. 3470 ULCCEx747 Page 4-11 4-1-06 REV.8 Fryer - Multiple Nozzle Protection (Continued) Maximum Area Dimension - Multiple Nozzle Fryer Protection Max. Size Module Max. Size Module Overall Type of Frypot Only With Drlpboard Nozzle Full or Split Vat Full or Split Vat 21 In. x 210 in.2 21 in. x 294 in.2 230 (53cmx.14m2) (53cmx.19m2) Full or Split Vat Full or Split Vat 21 in. x 210 in.2 21 in. x 294 in.2 245 (53 cmx .14 m2) (53 cm .19 m2) Full or Split Vat Full or Split Vat 21 in. x 210 in.2 21 in. x 294 in.2 290 ..(53cmx.14m (53cmx.19m2) 25 3/8 x 370.5 in2 253/8 x 495 in2 290 (65 cm x .24 m2) (65 cm x .32 m2) ' Full or Split Vat Full or Split Vat 26 1/2 in. x 203 in.2 26 1/2 in.x 384 1/4 in.2 290 (67cmx.13m2) (67 cmx .25 m2) 253/8 x 370.5 in2 253/8 x 495 In2 3N (65cmx.24m2) (65cmx0.32m2) 273/4 x 324 In.2 273/4 x 497 in2 3N (70.5 cm x .21 m2) (70.5 cm x .32 m2) Nozzle Height Nozzle Above Top of Fryer Location 27 in. to 47 in. See Figure 21 (69 cm to 119 cm) 20 in. to 27 In. See Figure 21 (51 to 69 cm) 13 in. to 16 in. See Figure 22 (33 to 41 cm) 13 in. to 16 in. See Figure 22 (33 to 41 cm) 16 In. to 27 in. See Figure 22 (41 to 69 cm) See Figure 23 See FIgure 23 25 in. to 35 In. See Figure 24 (64 cm to 89 cm) 84 IN. (86 cm) MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE 9 AND CENTER I HAZARD AREA FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD POSITION NOZZLE TIP ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE MODULE IT IS PROTECTING AND AIM AT THE MIDPOINT OF THAT MODULAR AREA. FIGURE 21 FRYER WITHOUT DRIPBOARD FRYER WITh DRIPBOARD 3M NOZZLE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE PERIMETER OF THE MODULAR if IS PROTECTING AND AIMED AT THE MIDPOINT OF THAT RESPECTIVE MODULE AREA. FIGURE 23 21 In. (53 MINIMUM VERTICAL NOZZLE HEIGHT FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE RESPECTIVE MODULAR AREA ± S IN. (1.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE MODULE AND ± I IN. (2.5 an) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE MODULE AND AIMED AT THE MIDPOINT OF THE MODULE. FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD THE SN NOZZLE TIP MUST BE POSITIONED ANYWHERE ALONG OR WITHIN THE PERIMETER AND FORWARD OF THE RIGHT-TO-LEFT CENTERLINE OF THE COOKING AREA. THE AIMING POINT OF THE NOZZLE MUST BE AT THE DIAGONAL CENTER OF THE MODULAR COOKING AREA. FIGURE 22. FIGURE 24 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-24 REV.6 4-1-06 Gas-Radiant/Electric Char-Broiler Protection The R-102 system uses the 1 N nozzle, (Part No. 419335) for gas- ' radiant/electric char-broiler protection. The nozzle tip on the 1 nozzle is stamped with a IN, indicating that this is a one-flow nozzle and must be counted as one flow number. One IN nozzle will proteât a hazard with a maximum length of 36 in. (91 cm) and a total cooking area which does not exceed 864 sq. in. (5574 sq. cm). The nozzle tip must be located 15 to 40 in. (38 to 102 cm) above the hazard surface. When using this o. nozzle for gas-radiant/electric char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking surface. See Figure 51. COOKING AREA 40 IN. (102 cm) MAXIMUM 15 IN. (38cm) MINIMUM FIGURE 51 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-28 REV.5 4-1-06 Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart Is for general reference only. See complete details for each type of hazard. Minimum : Nozzle Tip Hazard Maximum Hazard Dimensions Nozzle Quantity Nozzle Height Nozzle Part No. Stamping - Flow No. 'Duct or Transition Length - Unlimited 1 - 430912 1W (Single Nozzle) Perimeter —50 in. (127 cm) Diameter —16 in. (40.6 cm) Duct or Transition Length - Unlimited 1 - 419337 2W (Single Nozzle) Perimeter-100 in. (254 cm) Diameter —31 7/8 in. (81 cm) Duct or Transition Length —Unlimited 2 - 419337 2W (Dual Nozzle) Perimeter —150 in. (381 cm) Diameter —48 In. (122 cm) Electrostatic Precipitator Individual Cell 1 - 419334 1/2N (At Base of Duct) Plenum Length —10 ft. (3.1 m) 1 - 419335 iN (Horizontal Protection) 'Plenum Length —6 ft. (1.8 m) 1 - 430192 1W (Horizontal Protection) Width —4 ft. (1.2 m) 1 - 419336 1W Plenum Length —4ft. (1.2 m) 1 - 419336 1W (Vertical Protection) Width— 4 ft. (1.2 m) 'Fryer (Split or Maximum Size Non-Split Vat) (without drip board) 14 In. (36 cm) x 15 in. (38 cm) .1 13-16 in. 419342 290 Low Proximity (33 —41 cm) Fryer (Split or Maximum Size Non-Split Vat) (without drip board) 14 1/2 in. (37 cm) x 141n. (36 cm) I 16-27 in. 419342 290 Medium Proximity (41 —69 cm) Fryer (Split or Maximum Size Non-Split Vat)* (without drip board) 15 in. 38 cm) x 14in.(36cm) High Proximity 1 27-47 in. 419339 230 Medium Proximity 1 20-27 in. 419340 245 Fryer (Non-Split Vat Only) Maximum Size (without drip board) 191/2 in. (49.5 cm)x 19 in. (48.2 cm) High Proximity 1 21 —34 in. 419338 3N Low Proximity I 13-16 in. 419342 290 Maximum Size (without drip board) 18 in. (45.7 cm) x 18 In. (45.7 cm) High Proximity 1 25-35 in. 419338 3N (64-89 cm) For multiple nozzle protection of single fryOrs, see detailed Information on Pages 4-12 through 4-14. 27-47 in. 20-27 in. 21 —34 in. 13-16 in. 25-35 in. (64-89 cm) 13-16 in. (33 —41 cm) 16 —27 in. (41 —69cm) 30-40 in. (76-102 cm) 40-48 in. '(102-122 cm) (With Backshelt) 40-50 in. (102-127 cm) 30-40 In. (76-102 cm) 15-20 in. (38-51cm) 419339 230 419340 245 419338 3N 419342 290 419338 3N 419342 290 419342 290 419335 IN 419333 IF 419340 245 419341 260 419342 290 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4.29 4-1-06 REV.5 Nozzle Application Chart (Continued) Minimum Nozzle lip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heights Part No. Flow No, Fryer (Non-Split Maximum Size Vat Only)* (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in.x 14 in. (38 cm x 36 cm)) High Proximity Medium Proximity Maximum Size (with drip board) 253/8 in. (64.4 cm) x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 19 1/2 in. (49.5 cm) x 19 in. (48.2cm) High Proximity Low Proximity Maximum' Size ,(with drip board) . : 18 in. (45.7 cm) x 273/4 in. (70.5 cm) High Proximity Fryer (Split or Maximum Size Non-Split Vat) '(with drip board) l4 in. (36 cm) x 21 in. (53 cm) Low Proximity Fryer (Split or Maximum Size Non-Split Vat) (with drip board) 14 1/2 in. (37 cm) x 26 1/2 in. (67 cm) Medium Proximity Range Longest Side :32 in. (81 cm) Area —384 sq. in. (2477 sq. cm) Longest Side 28 in. (71 cm) Area —336 sq. in. (2168 sq. cm) Longest Side (High Proximity) 28 in. (71 cm) Area —672 sq. In. (4335 sq. cm) Longest Side (Medium Proximity) 32 in. (81 cm) Area —768 sq. in. (4955 sq. cm) Longest Side (Low Proximity) 2 36 in. (91 cm) Area —1008 sq. in. (6503 sq. cm) For multiple nozzle pmtectlon of single fryem see detailed information on Pages 4- 7 t h m u g h 4 - 1 1 . SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-30 REV.3 10-1-02 Nozzle Application Chart (Continued) Minimum Nozzle Tip Hazard Maximum Hazard Dimensions Nozzle Quantity Nozzle Heights Nozzle • Part No Stamping - Flow No. Griddle Longest Side (High Proximity) 1 30-50 in. 419341 260 48 in. (122 cm) (76-127 cm) Area —1440 sq. in. (perimeter (9290 Sq. cm) located) Longest Side (High Proximity) 1 30-50 in. . 419342 290 30 in. (76 cm) (76-127 cm) Area —720 sq. in. (center located) (4845 sq. cm) Longest Side (High ProximIty) 1 35 - 40 in. 419335/417332 1N/1NSS 361n.(91 cm) (89-102 cm) . Area - 1080 sq. in. (perimeter located) (6968 sq. cm) Longest Side 1 20-30 in. 419342 .290 (Medium Proximity) (51 —76 cm) 48 in.. (122 cm) (perimeter Area— 1440 sq. in. located) (9290 sq. cm) Longest Side (Low Proximity) 1 10-20 in. 419343 2120 48 in. (122 cm) (25 —51 cm) Area —1440 sq. in. (perimeter (9290 sq. cm) . located) . . Chain Broiler Longest Side —34 in. (86 cm) 2 10-26 in. 419336/417333 . IW/1WSS (Overhead Protection) Area - 1088 sq. In. (25 —66 cm) (7019 sq. cm) Chain Broiler Length —43 in. (109 cm) 2 1•— 3 in 4193351417332 . iN/i NSS (Horizontal Protection) Width —31 in. (79 cm) (3-8 cm) Gas-Radiant Char-Broiler Longest Side —36 in. (91 cm) 1 15-40 in. 419335/417332 iN/i NSS Area — 864 sq. in. (38-102cm) (5574 sq. cm) Electric Char-Broiler Longest Side —34 in. (86 cm) 1 20-50 in. 419335/417332 iN/i NSS Area —680 sq. in. (51 - 127 cm) (4388 sq. cm) Lava-Rock Broiler Longest Side —24 in. (61 cm) 1 18-35 In. 419335/417332 1 N/l NSS Area — 312 sq. in. (46-89cm) (2013 sq. cm) Natural Charcoal Broiler Longest Side - 24 in. (61 cm) 1 18-40 in. 419335/417332 IN/i NSS Area-288 sq. in. (46 —102 cm) (1858 sq. cm) Lava-Rock or Natural Longest Side —30 in. (76 cm) 1 14-40 in. . 419338 3N Charcoal Char-Broiler Area —720 sq. in. (36-102 cm) (4645 sq. cm) Minimurn chain broflerexhaust opening -.121n.xl2 In. (31 cmx3l m), and not Ins than o%of Internal broiler size. I- SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-48 REV.4 4-1-06 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements —1.5 Gallon System DUCT, PLENUM, AND APPLIANCE PROTECTION This option allows for duct protection, plenum protection, appliance protection, or any combination. When using a combination of plenum and duct protection only, only one duct nozzle, either a 1W, or a 2W, may be used. The previous Option 2 (using 2WH nozzle for plenum and duct protection) still can be utilized. For detailed design information, see previous version of this manual, Part No. 418087-06. Note: When using this option, all design parameters must:be followed as listed in manual version -06. All distribution piping, supply and branch, must be 3/8 in. Schedule 40 black iron, chrome-plated, or stainless steel. Each 1.5 gallon tank allows a maximum of five flow numbers.* a. The pipe length between the start of the first branch line and the start of the last branch line must not exceed 8 ft. (2.4 m). When the supply line is split, the combined length of both legs of the supply line (start of first branch line to start of last branch line) must not exceed 8 ft. (2.4 m). See Figure 91. The combined length of all branch lines must not exceed 22 ft.. (6.7 m). See Figure 92. The requirements of the'following table must not be exceeded: Duct Requirements . Supply Branch Line Pipe Size 3/8 in. 3/8 in. Maximum Length 40 ft. 6 ft. (12.2 m) (1.8 m) Maximum Rise 61% -4 ft. (1.8m) (1.2m) Maximum 900 Elbow 9 . 4 Maximum Tees 1 1 Maximum Flow Numbers 5* 2 START OF LAST BRANCH LINE START OF FIRST BRANCH LINE SUPPLY . •.j;ç- •miJ LINE TEE L LENGTH MUST NOT EXCEED a Fr. iSTART OF LAST .J BRANCH LINESTART OF FIRST BRANCH LINE FIGURE 91 1W NOZZLE (BRANCH LINES IN BOLD) . COMBINED LENGTH MUST NOT EXCEED 22 Ft (6.7 m) FIGURE 92 000715 Plenum Appliance 3/8 in. 3/8 in. 4 f 10 f (12m) (3m) 2 f 21t (.6 m) (.6 m 4 6 2. 3. 2 . .3 ExceptIons: . . Six (6)110w numbers are allowed when a duct branch One Is the last branch line on the pipIng network and no IN nozzles are used to protect wOks orgrldctes. SIx (6) flow numbers are allowed when sIx (6) IN nozzles are used and none of the nozzles axe used to protect woks and griddles. NOTE: Only five (5) flow numbers are allowed If a IN nozzle Is used for wok or griddle protection. Six (6) flow numbers are allowed when only two (2) 3N nozzles are used LINE MUST NOT EXCEED 24 FT. (7.3 m) 2W NOZZLE 3 BRANCH LINES IN NOZZLE :J~ _'*- IN NOZZLE SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-49 4-1-06 REV.4 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements -3.0 Gallon System The maximum length between the start of the first branch line and the start of the last branch line must not exceed 24 ft. (7.3 m). When the supply line is. split, the combined total of both legs of the supply fine (from the start of the first branch line to the start of the last branch line) must not exceed 24 ft. (7.3 m). See Figure 93. The total length of all branch lines must not exceed 36 ft. 10. (10.9 m). See Figure 93. Use a 3/8 in. union to connect the tank adaptor to the 3/8 in. supply line. A maximum of two nozzles are allowed per duct branch line. The requirements of the following table must not be exceeded: 230 NOZZLE / 245 NOZZLE 112N NOZZLE (BRANCH LINE IN BOLD) COMBINED LENGTH MUST 000502 NOT EXCEED 36 Ft (10.9 m) FIGURE 93 Duct Plenum Appliance Requirements Supply Line Branch Una Branch Urie Branch Line Pipe Size . 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 8 ft. 4 ft . 12 ft. (12.2 m) (2.4 m) (1.2 m) (3.7 m) Maximum Rise 6 ft 4 ft 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6m). Maximum 90° .9 4 . 4 6 Elbows Maximum Tees 1 2 2 4 Maximum Flow 11* .4 2 4 Numbers Exceptlons: I. Twelve (12)110w numbers are allowed In anyone tank for duct and plenum protection only. flvelve (12) flow numbers are allowed With any one tank using only two-How appllancenozzles. Twelve (12)110w numbers are allowed With anyone tank using only three-flow appliance nozzles. SpecIal Instructions: Twelve (12)110w numbers are.aflowed when four (4) Dean Ifldusti1es Gil Gas Fryars are protected at low proximity as shown In Figure 58 on Page 4-32. The discharge piping must be as shown In FIgure 59 on Page 4-32. For certain McDonald applications, 11.5110w numbers are allowed when using a combination of one (1) 2W duct nozzle, one (1) 112N electrostatic precipitator nozzle, one (1) 1N plenum nozzle, and four (4) two4tow appliance nozzles. Contact Maul Applications Englneedng Department for additional information. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-52 REV.3 4-1-06 DISTRIBUTION PIPINGREQUIREMENTS (Continued) Distribution Piping Requirements -9.0 Gallon System This optional configuration consists only of three 3-gallon tanks, all pressurized from a single double-tank nitrogen cartridge with expellant gas hoses connected as shown in Figure 97. Tanks No. 1 and No.2 must be connected directly to the regulator with sepa-rate expellant gas hoses and Tank No. 3 must be connected to 'Tank No.2 with a third expellant gas hose as shown in Figure 97. Each tank must be connected to an independent distribution pip- sing network as shown in Figure 97. Distribution piping require- ments for each network must be as follows: The maximum length between the start of the first branch line and the start of the last branch line must not exceed 24 ft. (7.3 m). When the supply line is split the combined total of both legs of the supply line (from the start of the first branch line to the start of the last branch tine) must not exceed 24 ft. ' (7.3 m). See Figure 93. The total length of all branch lines must not exceed 36 ft. ' (10.9 m). See-Figure 93. Use a 3/8 in. union to connect the tank adaptor to the 3/8 in. supply line. A maximum of two nozzles are allowed per duct branch line. When using this 9.0 gallon system configuration, no nianl- folding of distribution piping is allowed. When an ANSUL AUTOMAN RégulatedRelease is utilized in this configuration, additional regulator actuators cannot be used. Only 3 gallon tanks can be utilized In- this configuration. The requirements of the following table must not be exceeded. for each 3 gallon tank: &0 &0 &0, GALLON GALLON GALLON TANK TANK lANK NO.3 NO.2 NO.1 TWO TANK ENCLOSURE 3 GALLON REGULATED DOUBLE TAM( NITROGEN ASSEMBLY PART NO. RELEASE ASSEMBLY, CARTRIDGE OR 430324 (INCLUDES (2) OR 3 GALLON LT4001.30 CARTRIDGE HOSES AND (2) REGULATED ACTUATOR (REGULATED ACTUATOR GROMMETS) ASSEMBLY ONLY) NOTE: IFiWOTANK ENCLOSURE ASSEMBLY..PART NO. 43ON4.1$ CONNECTED TO THE 3 GALLON REGULATED RELEASE ASSEMBLY. NO ADDrrIoNA1. REGULATED ACTUATOR(S) ASSEMBUES CAN BE USED. FIGURE 97 new? Duct Requirements Supply Line Branch Line Plenum Branch Una Appliance Branch Una. Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 8 ft. .4 It. 12 it. (12.2 m) (2.4 m) (1.2 m) (3.7 m) Maximum Rise 6 ft. 4 ft. 2 ft. (1.8 m) (1.2 rn) (.6 m) (.6 m) Maximum 900 9 4 4 6 Elbows Maxlmum.Tees 1 2 2 4 Maximum Flow 11* 4 2 4 Numbers EXcapttons: Twa We (12) flow numbers are allowed In anyone tank for duct and plenum protection ONLY. Twelve (12) flow numbers are allowed with any one tank using only heo-lbe appliance nozzles. Twelve (12) flow numbers are allowed with any one tank using only threeftow appliance nozzles. special Instruatloow When four (4) Dean lndustiles OTT Gas Fvyers are protected at low prrsdmfty as shown In Figure 58 on Page 442. the discharge piping must be asshownIn Figure 59 on Page 4-32. For certain McDonald applications. 11.5 flow numbers are allowed when using a combinatIon of one (I) 2W duct nozzle. one (I) II2N electrostatic precipitator nozzle. one (1) 1N plenum node. and four (4) 1w0410w appliance nozzles. Contact Maul Applications Englnaedng Department 1* additional Information.