Loading...
HomeMy WebLinkAbout2850 GAZELLE CT; ; FPC2022-0229PERMIT REPORT Uity of Carlsbad Print Date: 12/18/2023 Job Address: 2850 GAZELLE CT, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2091202700 Track #: Valuation: $235,689.96 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Permit No: FPC2022-0229 Status: Closed - Finaled Fire Alarm Applied: 12/20/2022 Issued: 01/04/2023 Finaled Close Out: 04/12/2023 Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Maldonado, Adalmira Project Title: Description: IONIS -FIRE ALARM TI TO INSTALL 6 NEW NOTIFICATION DEVICES & RELOCATION OF 3 EXISTING NOTIFICATION DEVICES THROUGHOUT 1ST FLR Applicant: FPContractor: ELECTRONIC CONTROLS SYSTEM LLC ELECTRONIC CONTROL SYSTEMS LLC RICHARD SAYLORS 12575 KIRKHAM CT 12575 KIRKHAM CT POWAY, CA 92064-8844 POWAY, CA 92064-8844 (858) 513-1911 (858) 513-1911 FEE AMOUNT FIRE TI Fire Alarm System $735.00 Total Fees: $735.00 Total Payments To Date: $735.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 442-339-2665 1 Inspections: 442-339-2660 1 www.carlsbadca.gov Albireo Energy Partnering for Success Seminar Room Conversion lonis Pharmaceuticals 2850 Gazelle Court Carlsbad CA 92010 Product Data Submittal Fire Alarm System December 16, 2022 Albireo Energy' 12575 Kirkham Ct ' Poway, CA 92064 • Phone: 858-513-1911 • www.albireoenergy.com \ Albireo Energy Partnering for Success Table of Contents 1. Fire Alarm Equipment BPSIOA GCH FWN-S7VMC EGGS VWE EGCVWF Notification Power Supply (Provided for Reference Only) Existing Ceiling Mount Speaker Strobe Ceiling Mount Speaker Strobe Ceiling Mount Strobe Albireo Energy. 12575 Kirkham Ct Poway, CA 92064 • Phone: 858-513-1911 • www.albireoenergy.com I E DWARDB EDWARDS Catalog 1> Power Supplies and Accessories I FE SAFFTY NCIDFNT MA\AGEMFI\T Remote Booster Power Supplies BPS6A, BPS1OA 0229 Overview The Booster Power Supply (BPS) is UL 864, 10th Edition listed power supply. It is a 24 Vdc filtered-regulated, and supervised unit that can easily be configured to provide additional notification appliance circuits (NACs) or auxiliary power for Mass Notification! Emergency Communication (MNEC), as well as life safety applica- tions. The BPS contains the circuitry to monitor and charge internal or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. The BPS has four Class B (convert- ible to two Class A) NACs. These can be activated in one or two groups from the BPS'S unique dual input circuits. The BPS is available in 6.5 or 10 ampere models. Each output circuit has a capacity of three amperes; total current draw cannot exceed the unit's rating. The BPS meets current UL requirements and is listed under the following standards: Standard (CCN) Description UL864 10th edition (lJ0)0 Fire Alarm Systems UL636 (PNET UEHX7) Holdup Pd arm Units and Systems UL609 (OD(, AOTX7)_tocal Burglar Pdarm Units and Systems UL365 ApAwW, APAR) Police 5taiton Connected Burglar AJarm Unii and ystems UL1076 (APOU, APOU7)Propnetary Burglar Alarm System Units UL1610(AMC)Q Ciâf Station AJarm Unit ULc-5527 (UO)0(C)Control Units. Fire Alarm (Canada) ULC-S3iA7) Local Burglar Man Units and Systems (Canada) C22.2 No. 205 signaling Equipment (Canada) Standard Features Allows for reliable filtered and regulated power to be installed where needed Cost effective system expansion Provides for Genesis and Enhanced Integrity notification ap- pliance synchronization Supports coded output operation Self-restoring overcurrent protection Multiple signal rates Can be cascaded or controlled independently Easy field configuration On-board diagnostic LEDs identify wiring or internal faults Standard EDWARDS keyed lockable steel cabinet with re- movable door 110 and 230 Vac models available Accommodates 18 to 12 AWG wire sizes Optional tamper switch Dual battery charging rates Optional earthquake hardening: OSHPD seismic pre-approval for component Importance Factor 1.5 Page 1 of 4 DATA SHEET E85005-0125 Not to be used for nstatlation purposes. Issue 1.2 Application The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations and can easily be installed where needed. Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay (if programmed). While this provides indication to the host system, the BPS can still be activated upon command. A separate AC Fail contact is available on the BPS circuit board, which can be programmed for trouble or AC Fail. There are seven on-board diagnostic LEDs: one for each NAC fault, one for battery fault, one for ground fault, and one for AC power. The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VDC (filtered-regulated) or 11 to 33 Vdc (full-wave rectified, unfiltered). The first input circuit can be configured to activate 1-4 of the four possible outputs. The second input circuit can be configured to control circuits 3 and 4. When outputs are configured for auxiliary operation, these circuits can be configured to stay on or automatically deactivate 30 sec- onds after AC power is lost. This feature makes these ciicuits ideal for door holder applications. The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation modules. Dimensions TI Top View 00 D2-"l k D3 C a, 84— D4 —+8 S S Front View S a) 116 c7j 0 0 CD CL All knockouts a, for 3/4 in conduit < I (1.9 cm) Dl BPS NACs can be configured for a 3-3-3 temporal or continuous Dl D2 D3 D4 D5 DO output. This makes the BPS ideal for applications requiring signal- 17.01 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in ing rates that are not available from the main system. (43.2 cm) (8.9 cm) (33.0 cm) (116.5 cm) (8.6 cm) (30.4 cm) In addition to the internally generated signal rates, the BPS can also be configured to follow the coded signal rate of the main system NACs. This allows for the seamless expansion of existing Wire routing Power-limited NACs. wiring area The BPS enclosure has mounting brackets for up to three Signa- ture modules to the right of the circuit board. Engineering Specification Supply, where needed, EDWARDS BPS Series Booster Power Supplies (BPS) that are interconnected to and supervised by the main system. The BPS shall function as a stand-alone auxiliary power supply with its own fully-supervised battery compliment. The BPS battery compliment shall be sized to match the require- ments of the main system. The BPS shall be capable of supervis- ing and charging batteries having the capacity of 24 ampere-hours for Mass Notification/Emergency Communication (MNEC), life safety applications. <<The BPS shall be capable of installation for a seismic com- ponent Importance Factor of 1.5.>> The BPS shall provide a minimum of four independent, fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- vided with automatically restoring overcurrent protection. The BPS shall be operable from the main system NAC and/or EDWARDS Signature Series control modules. BPS NACs shall be configurable for continuous or 3-3-3 temporal rate. Fault conditions on the BPS shall not impede operation of main system NAC. The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Notes 1. Main:ain 1/4-inch (6 mm) spacing between power-limited and nonpower-limited wiring or use type FPL FPLR, or FPLP cable per NEC. Power-limited and supervised when not configured as auxdiary power. Non- supervised when configured as auxiliary power. Source must be power-limited. Source determines supervision. 4. When using larger batteries, make sure to position the battery terminals towards the door. Route AC supply through these knockouts only (Nonpower-limited and supervised) Page 2 of 4 DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1.2 Typical Wiring Single or cascaded booster i NAC Circuit anywhere on a notification appliance circuit I NAC circuit Existing NAC end-of-line resistors are not required to be Fire Alarm installed at the booster's terminals. This allows multiple Control Panel boosters to be driven from a single NAG circuit without the need for special configurations. To next signaling device, booster, or EOL resistor Ifl CI I a a ) NAC output #1 I a a ) NAC output #3 - M ) NAC output #4 0 0 ) NAC output #2 S. g Booster Power Suoolv Configuring the Booster for Muhple CC1 (S) modules using the AC Power Fail delay operation* BPS's sense inputs o TB1 Notification appliance circuit (NAC) TB1 °Notification appliance circuit (NAC) NAC1/+ - UL listed NAC1/ + UL listed AUX1 - - EOL 15kO AUX1 - EOL 15 KW NAC2/ + AUX2 - Notification appliance circuit (NAC) AUX2 - NAC2/ + j Notification appliance circuit (NAC) NACS/ + 199 — UL listed NAC3/ + :i— UL listed AUX3 - — AUX3 - 19 V EOL 15 KW NAM + NAC4/ + AUX4 - AUX4 - 200 mAAUX ±. 200 mAAUX - Continuous - ___________ Cortinuous IN IN Sense 1 COM Sense 1 COM : OUT [jjjj OUT EP EOL47K IN _ 2 COM ______109 EOL 47 kO Sense 2 coM ;OUT Sense C1(S) module [1][3] OUT EOL IN L 47K NO COM - 00 76 5 4 3 2 1 ElTrouble NO Trouble COM NC +1- NC II 109 TB2 ° _________ ___________ Tjnext TB2 CCI(S) module CC1(S) module . CT1 I Data out to I 00 00 8765 4321 8765 4321 I Datainfrom previous device mouI [411 I device or Signature The Booster supports AC Power fal delay of three hours via its trouble contact when dip switch SW2-6 is on. Mother troJbles are reported to supervising module or panel without delay As Sense inputs. Page 3 of 4 DATA SHEET E85005-0125 Not to be used for nstallation purposes. Issue 1.2 Specifications Model 6.5 amp Booster 10 amp Booster AC Une Voftage 120VAC or 220-240VAC 50/60Hz 120VAC or 220-240VAC 50/60Hz 390 watts 580 watts Notification Appliance 3.0A max. per circuit @ 24Vdc 3.0A max. per circuit @ 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 10A max total all NACs Trouble Relay 2 Amps @ 30Vdc Auxiliary Outputs Four configurable outputs replace NACs 1, 2, 3 or 4. as auxiliary outputs and 200 mA dedicated auxiliary. (See note 1.) Input Current (from an existing NAC) 3mA @ 12Vdc, 6mA © 24Vdc Booster Internal Supervisory Current 70mA + 35 mA for each circuit set to AUX Booster Internal Alarm Current 270mA Signature Mounting Space Accomodates three two-gang modules. Maximum Battery Size 10 Amp Hours (2 of 12V10A) in cabinet up to 24 Amp hours with external battery cabinet for fire applications. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93% non condensing © 32°C Temperature Rating 320 to 120°F (00 to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous, 3-3-3 temporal, or follow installed panel's NAC. Ground Fault Detection Enable or Disable via jumper Agency Listings UL, ULC, CSFM bWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.flre@canier.com Webste: edwardsfiresafetv.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2021 Carrier All rights reserved. Page 4 of 4 1. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Number Description Shipping wt. lb (kg) BPS6A 6.5 Amp Booster Power Supply 13(5.9) BPS6AC 6.5 Amp Booster Power Supply (ULC) 13(5.9) BPS6N230 6.5 Amp Booster Power Supply (220V) 13(5.9) BPSiOA 10 Amp Booster Power Supply 13(5.9) BPS10AC 10 Amp Booster Power Supply (ULC) 13(5.9) BPS1 OA/230 10 Amp Booster Power Supply (220 13(5.9) Related Equipment Requires installation of sepa- 12V6A5 7.2 Amp Hour Battery; two required 3.4(1.6) rate battery cabinet. 12V10A10 AmpHour Battery,tworequired 9.5(4.3) For earthquake anchorage, 3-TAMP Tamper switch including detailed mounting weights and center of gravity BPS-CVR Electronics Protective Cover detail, refer to Seismic Applica- BC-1 EQ Seismic Kit for BC-i. Order BC-i separately. See note 2 tion Guide 3101676. Approval BPSEQ Seismic kit for BPS6A or BPS10 Booster Power Supplies. See of panel anchorage to site note 2 structure may require local AHJ, structural or civil engineer BC-1 Battery Cabinet (up to2-40 AmpHour Batteries)58(26.4) review. BC-2 Battery Cabinet (up to 2 - i7 Amp Hour Batteries) 19(8.6) 12V1 7A 18 Amp Hour Battery, two required (see note 1) 13(5.9) 12V24A 24 Amp Hour Battery, two required (see note 1) 20(9.07) DATA SHEET E85005-0125 Not to be used for installation purposes. Issue 1.2 ( - PLER1 FIRE I E r. WARDS EDWARDS Catalog I> Speakers, Telephones LIFE SAFETY INCIDENT MANAGEMENT Ceiling Speakers, Speaker-Strobes Genesis GO Series IVIEA 7320-1657: 0211/0285 See Specifications Section for listings details. Overview The Genesis line of ceiling life safety and emergency communica- tions speakers and speaker-strobes combine high performance output with a low profile design to deliver a life safety signal solu- tion that's as versatile as it is effective. While they are designed to mount inconspicuously overhead, these devices are also rated for wall-mounted applications. Clear-lens speaker-strobes are available in high and low candela models, which feature 15 to 95, or 95 to 177 cd output (see order- ing information). Ceiling speakers feature 1/4 W to 2 W operation, which allows devices to be easily fine-tuned to achieve maximum benefit in exchange for the lowest possible system overhead. Light output and wattage tap settings are selectable with conven- iently-located switches. Settings remain clearly visible even after final installation, yet they are locked in place to prevent unauthorized movement after installation. High fidelity models meet the NPFA 520 Hz requirements for newly construced commercial sleeping areas. They also produce crisp, clear voice audio output that is highly intelligible over large areas. These low-profile appliances feature textured housings in architec- turally neutral white or eye-catching life safety red. Optional ALERT or FIRE markings make them ideal for applications that require differentiation between life safety and mass notification alerts. Standard Features High Fidelity 520 Hz speaker models available Low frequency output meets NFPA standards for newly con- structed commercial sleeping areas; increases sound fidelity and audio intelligibility. Field configurable - no need to remove the device - Select 1/4,1/2, 1, or 2 watt operation - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed Ideal for Mass Notification applications - blue and amber lens models available Unique low-profile design - 30 per cent slimmer profile than comparable signals - Available with white or red housings Unparalleled performance - loud 90 dBA output ensures clear, crisp audio - Precision strobe timing meets UL synchronization standards - 25 VAMS and 70 VRms models available Easy to install - Fits all standard 4-inch square electrical boxes with plenty of room for extra wire - no extension ring or trim plate needed - #18 - #12 AWG terminals - ideal for long runs, existing wiring Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL 1480-listed as life safety speaker - UL/ULC listed for ceiling or wall use Page 1 of 6 DATA SHEET E85001-0641 Not to be used for nstallation purposes. Issue 2.3 Strobe Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. See the Specifications table for compatible synchronization sources. Speaker Application The suggested sound pressure level for each signaling zone used with alert or alarm signals is a minimum of 15 dB above the aver- age ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater. This is measured 5 feet (1.5 m) above the floor. Doubling the distance from the signal to the ear will theoretically cause a 6 dB reduction in the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. Doubling the power output of a device (e.g.: a speaker from 1 W to 2 W) will increase the sound pressure level by 3 dBA. A 3 dBA difference represents a barely noticeable change in volume. Combination audible/visual signals must be installed in accor- dance with guidelines established for strobes. High Fidelity Models Genesis G4HF Series High Fidelity appliances provide highly intel- ligible voice audio output. They are also effective in areas subject to high levels of ambient noise. These appliances are approved for use in sleeping areas under conditions described below. Sleeping Room Applications Genesis GCHF Series High Fidelity appliances are ideal for hotels, dormitories, and other residential occupancies where audible output must meet the 520 Hz signaling characteristics required by NFPA 72. In sleeping areas, always ensure that the wattage tap of the speaker is set sufficiently high so that the sound pressure reaches at least 75 dBA-fast at the pillow. These appliances are part of an end-to-end audio system ap- proved for use in sleeping areas when used in conjunction with approved audio hardware and a factory-supplied 520 Hz tone. Check the System Compatibility List for other 520 Hz signaling requirements. NOTE: Speakers driven by third-party audio systems are not UL approved for use in sleeping rooms. Application Notes - Canada (Based in part on 1995 Canada National Building Code) The signal sound pressure level shall not exceed 110 dBA in any normally occupied area. The sound pressure level from an audible signal in a floor area used for occupancies other than residential occupancies shall not be less than 10 dBA above ambient levels, and never less than 65 dBA. In sleeping rooms the sound pres- sure level from an audible signal shall not be less than 75 dBA when any intervening doors between the device and the sleeping room are closed. Installation and Mounting All models are intended for indoor ceiling or wall applica- tions only. Speaker-strobes are mounted to a flush North-American 4 square electrical box, 21/ (54 mm) deep. Genesis ceiling speaker- strobes simply unlatch and hinge down to open. This gains access to mounting ------------------------------------------ screws and the selectable candela BOX wattage tap switches. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. Installation Note: When installed, these devices are not centered on the electrical box. Make sure boxes are mounted to compensate for this difference. Use the mount- ing template provided with installation sheet 3100614. Field Configuration Genesis ceiling speaker- strobes may be set for 1/4, ½, 1, or 2 watt operation. De- pending on the model, Gen- Wattage switch Indicator esis ceiling speaker-strobes have multi-candela output (see ordering information). Output settings are changed by simply opening the device and sliding the switches to the desired settings. The speaker-strobe does not have to be removed to change the output settings. The settings remain visible through small windows on the front of the device after the cover is closed. Mass Notification Applications ,, pLERT Genesis Mass Notification appliances bring the same high-performance life safety features and unobtrusive design to mass notification applications. Models are available with optional ALERT housing labels, which make them ideal for applications that require differentiation between life safety and mass notification alerts. Dimensions 6.8dia. (173 mm) 1.0 (25 mm) 8. a 211 mm) l0 (25pvn) O.60(I5 nm) Page 2016 DATA SHEET E85001-0641 Not to be used for installation purposes. Issue 2.3 Typical Sound Output (dBA) FaIr..? Spat.? Light output - (effective cd) - Pe?flt.geofr.t.dooIptt - at of UL versus U- Meapwed at 2 watts setting In m,echolc chamber ••- Hoileertal and vertical oUtpUft teffect the sene pattern. 520 Hz Hiah Fidelity models (dBA1 outout at 3.05 m 110 It.) 14 W 0.25W 81.4 81.5 81 25 ½ W 0.50W 84.5 84.3 84 VRMS 1 W 1.00W 88.2 87.2 87 2W 2.00W 90.0 90.1 91 70 14W 0.25W 81.5 1 81.9 81 ½W 0.50W 84.1 84.9 84 VRMS 1 W 1.10W 87.9 87.9 87 2W 2.30W 90.8 90.8 91 Standard Hz models (dRAt at 05 m 110 Wi 25 VRMS 14W 0.25W 81 ½W 0.50W 84 1W 1.00W 87 2W 2.00W 90 70 VRMS 14W 0.25W 81 ½W 0.50W 84 1W 1.00W 87 2W 2.00W 91 Current Draw Standard cd outout models Operating current, RIMS (A) VDC 0.109 0.151 0.281 0.318 VFWR 0.131 0.194 0.379 0.437 Ugrtt output (cd) Clear Lens 15 30 75 95 Amber Lens 13 26 65 82 Blue Lens 6 12 31 40 Hiah Cd outout models Operating current, RMS (A) C 0.330 0.392 0.502 0.565 R !Amber 0.432 0.518 0.643 0.693 Ugh output (cd) ar Lens 95 115 150 177 Lens 82 100 130 155 Blue Lens 48 59 78 80 vui = volts direct current, regulated and filtered. VFWR = Volts full wave rectified Operating currents shown above were measured at 16 VDC and 16 VFWR. *Sound level output notes: dBA = Decibels, A-weighted. UL1480 Sound level output at 10 ft (3.05 m) measured in a reverberant room using 400 to 4,000 Hz band limited pink noise. ULC-S541: Meets or exceeds 85dBA in an anechcic chamber at 10 ft (3.05 m) on at least one setting per code. Directional characteristics: Within 6 dB of on-axis Sound level when measured 90" off-axis (horizontal). Current Draw Notes Ught output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Current values are shown in mA. See note 1 111511 or "D" "30" or IIIl I" 75" or "B""95" or "A" "95" or "D" "11 5' or "C" 50 "1" or "Be 1 "177" or "A" RMS RMS RMS RMS RMS RMS RMS RMS 16Vdc 109 151 281 318 330 392 502 565 16Vfwr 131 194 379 437 432 518 643 693 Typical Current See "15" or note 1 "D" 1-30" or 1175l1 or 119511 or "A" "C" RMS RMS RMS RMS 16Vdc 94 140 273 325 20Vdc 74 108 205 244 24Vdc 63 90 168 194 33Vdc 16Vfwr 20Vfwr 48 126 108 70 187 156 124 368 281 139 403 333 24Vfwr 97 139 240 270 33Vfwr 89 119 1 197 214 ITypical ttCurrent 95 cd üllliIcdEflJlL 115 cd 150 cd 177 cd RMS RMS RMS RMS 333 392 499 551 259 303 378 429 212 245 306 342 155 484 380 180 211 236 724 604 570 438 673 537 318 361 434 484 245 269 1 308 1 338 Page 3of6 DATA SHEET E850010641 Not to be used for installation purposes. Issue 2.3 Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm wiring. Input voltage matching the voltage rating of the speaker (25 or 70 Vrms) 1 1,11,10 o;Ma] appliance, fire alarm To listed To next end-of-line control or return to panel control equipment Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Mounting Flush mount to North American 4-inh square electrical box, 2-1/8 (54 mm) inches deep, or 960A-4RF round flush box. No extension ring required. Suitable for indoor wall or ceiling applications. Wire connections Screw terminals: polarized inputs for speaker, #18 to #12 AWG (0.75 mm2 to 2.5 mml wire size. Operating environment Indoor only: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Agency listings and Meets ULC-S541, year 2004 UL requirements for standards UL1 638 and 1-11-1 971. Complies with UL1 480 Fifth Edition. approvals, GC Models ULJULC File Number: S2813. MEA, CSFM approved. CSFM File Number: 7320-1657: 0211/0285. Speaker-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. Agency listings and UL 464 Usted for low frequency signaling applications. Meets ULC-S541 , year 2004 UL requirements for standards approvals, Low Frequency UL1 638 and UL1 971. Complies with UL1 480 Fifth Edition. MEA, CSFM pending. Speaker-strobes comply with ADA GCHF Models Code of Federal Regulation Chapter 28 Part 36 Final Rule. Supervisory voltage 30 V max. Speaker Operating Voltage 25 Vrrns or 70 Vrms Speaker response 400 to 4,000 Hz Output See table on previous page. Strobe Light output Field selectable. See table on previous page. Operating current See table on previous page. Strobe output rating Clear: UL 1971, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Amber: CAN/CSA-C22.2 No. 205, UL 1638: selectable 13/26/65/82 cd (GCW*VMA), 82/100/130/155 cd (GCW*VMHA Blue: CAN/CSA-C22.2 No. 205, UL 1638: selectable 6/12/31/40 cd (GCW*VMB), 48/59/78/80 cd (GCW*VMHB) Strobe operating voltage 16 to 33 VDC (24 VDC nominal) or 16 to 33 VFWR (24 VFWR nominal) Strobe flash rate One flash per second, default. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Synchronization Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. Synchronization So ye Sources SIGA-CC1S, SIGA-MCC1S, SlGA-CC2A, SIGA-MCC2A, G1M-RM, BPS6A, BPS1OA, APS6A, APS10A, iO Series, Fireshield Plus 3, 5 and 10 zone. Lens Optical grade polycarbonate. Page 4 of 6 DATA SHEET E85001 -0641 Not to be used for installation purposes. Issue 2.3 Ordering Model Life safety Ai GCHFRF-S2\/? GCHFWF-S2V GCF-S2VM GC-S2VM GCHFRN-S2V GCHFWN-S2 GCHFRF-S2Vt GCHFWF-S2V GCF-S2VMH GCHFRN-S2V GCHFWN-S2 GC-S2VMH GCHFRF-S2 GCFR-S2 GCHFWF-S2 GCHFRN-S2 GCHFWN-S2 GC-S2 GCWN-S2 GCHFRF-S7VI GCHFWF-S7V GCF-S7VM GCHFRN-S7V GCHFWN-S7\ GCHFRF-S7V1 GCHFWF-S7V GCF-S7VMH GCHF!RN-S7V GCHFWN-S7\ GC-S7VMH GCHFRF-S7 GCFR-S7 GCHFWF-S7 GCF-S7 GCHFRN-S7 GCHFWN-S7 GC-S7 GCWN-S7 Page 5of6 DATA SHEET E850010641 Not to be used for installation purposes. Issue 2.3 Ordering Information I High I Text I Lens Strobe Speaker Shipping Model I Fidelry Marking I Color Output Voltage I Weight Mass riouicauon_Appliances, wnite_nousungs GCHFWA-S2VMA 1 ALERT 1 13,26,65, Amber I or 82 Cd None 25 Volt (Selectable 1/4, ½, 1, or 2 watt) GCWA-S2VMA GCHFWN-S2VMA I GCWN-S2VMA GCWN-S2VMC Clear 15,30,75, or 95 cd _________ GCHFWA-S2VMC I ALERT GCWA-S2VMC GCHFWAS2VMAH Amber I 82, 100, 130, or 155 cd I GCWA-S2VMAH GCHFWN-S2VMAH I None GCWN-S2VMAH GCWN-S2VMHC Clear 95,115,150, or 177 Cd ____ GCHFWA-S2VMCH I ALERT GCWA-S2VMHC GCHFWA-S2 Speaker only models GCWA-S2 1.62 lb. GCHFWA-S7VMA I ALERT (0.73 kg.) I Amber. 13. 26,65, or 82 cd GCWA-S7VMA GCHFWN-S7VMA GCWN-S7VMA None Selectable GCHFWN-S7VMB Blue 6, 12,31, or 40 Cd 70 V (Selectable ½, 1, or 2 watt) GCWN-S7VMC Clear _____ 15,30,75, or 95 Cd GCHFWA-S7VMC I ALERT GCWA-S7VMC GCHFWA-S7VMAH Amber 82 100,130, 1/4, , or 155 Cd GCWA-S7VMHA GCHFWN-S7VMAH - I None GCWN-S7VMHA Selectable GCHFWN-S7VMBH I Blue 48,59,78, or 80 Cd GCWN-S7VMHC Clear 95,115, 150, or 177 Cd GCHFWA-S7VMCH I I ALERT GCWA-S7VMHC GCHFWA-S7 tSpeakeronly models GCWA-S7 Zb WAR DS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.flre@caffler.com Webste: edwaidstiresafetv.com 8985 Town Center Pkwy Bradenton, FL 34202 02021 Canter Al rights reserved. Accessories Page 6 of 6 DATA SHEET E85001-0641 Not to be used for instalatuon purposes. Issue 2.3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 0- LISTING SERVICE LISTING No. 7320-1657:0324 Page 1 of 2 CATEGORY: 7320 - SPEAKERS LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models GCHFWA-S2, GCHRNA-57, GCHFRF-S2, GCHFRF-57, GCHFWF-52, GCHFWF-S7, GCHFRN-52, GCHFRN-S7, GCHFWN-S2 and GCHFWN-S7 Speakers. Models GCHFRF-S2VMC, GCHFRF-S7VMC, GCHFRN-S2VMC, GCHFRN-S7VMC, GCHFWA-S2VMC, GCHFWA-S7VMC, GCHFWF-S2VMC, GCHFWF-S7VMC, GCHFWN-S2VMC and GCHFWN-S7VMC Speaker/Strobes. Models GCHFRF-S2VMCH, GCHFRF-S7VMCH, GCHFRN-S2VMCH, GCHFRN-S7VMCH, GCHFWA-S2VMCH, GCHFWA-S7VMCH, GCHFWF-S2VMCH, GCHFWF-S7VMCH, GCHFWN-S2VMCH and GCHFWN-S7VMCH Speaker/Strobes. Models GCHFWA-S2VMA, GCHFWA-S7VMA, GCHFWN-S2VMA and GCHFWN-S7VMA Speaker/Strobes. Models GCHFWA-S2VMAH, GCHFWA-S7VMAH, GCHFWN-S2VMAH and GCHFWN-S7VMAH Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 25 Vrms or 70 Vrms 1/4W, 1/2W, 1W, or 2W Normal candela, clear lens: 15/30/75/95 cd Normal candela, amber lens: 13/26/65/82 cd High candela, clear lens: 95/115/150/177 cd High candela, amber lens: 821100/130/155 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name model number, electrical/candela rating and UL label. 07-21-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7320-1657:0324 Page 2 of 2 APPROVAL: Listed as speakers and speaker/strobes for use with separately listed compatible fire alarm control unit. Clear lens models (suffix ending in C or CH) are suitable for the hearing impaired. The lights are only considered synchronized when used in conjunction with Model GIM-RM sync module (CSFM No. 7300-1657:0201) or Model SIGA-CCIS auto-sync output module (CSFM No. 7300-1657:0121). For indoor ceiling mounted use only. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2010 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to listee's Installation Instruction Manual for details. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) is required for sleeping areas in accordance with NFPA 72, 2010 Edition is required, the appliance must be used with a fire alarm control unit that can generate the low frequency signal. Refer to listee's Installation Instruction Manual for details. 07-21-15 gt S This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division * 7320-1657:0516 FC 1I pr KIdde Technology that saves lives Ceiling Mount Speakers and Speaker-Strobes Genesis LED EGGS Series Overview Genesis LED EGOS Series speakers and speaker-strobes combine high performance output with a sleek low profile design and energy-efficient technology that makes them less expensive to install and operate. High performance LEDs require fewer power supplies, backup power, and batteries. These new appliances are designed with energy-efficiency, and life safety in mind. Speakers feature selectable wattage taps, while speaker- strobes allow for both wattage and light output levels to be configured in the field. Both settings remain clearly visible - even after final installation. Speakers are also capable of both 25V and 70V and voltage in a single model with a field selectable switch. All this flexibility allows devices to be easily fine-tuned to exactly how they're needed to perform. Al Genesis speakers include a DC blocking capacitor to allow electrical supervision of the audio distribution circuit. Genesis LED EGOS Series uses high efficiency optics, combined with patented electronics, to deliver a highly controlled and efficiently focused light distribution pattern in exchange for lower current requirements. Strobes feature field- selectable 15, 30,75, or 115 cd light output. Compared with Xenon-type strobes, Genesis LED EGOS Series appliances offer greatly reduced current draw which provides benefits in longer circuit lengths, more devices per circuit, smaller wire gauge and reduced power supply quantities for an installation. They are also backwards compatible with legacy strobes, so there's no need to replace all your existing devices to upgrade to ' Speakers and Telephones new LED technology. In fact, EGOS strobes can be mixed on the same circuit and used in the same field of view as Xenon-based strobes. This makes Genesis LED EGOS Series ideal for new installations and retrofits alike. Field-configurable sound output levels provide the flexibility modern life safety projects demand, while the Genesis LED control protocol keeps multiple strobes on compatible NAO circuits synchronized to well within NFPA 72 requirements. They also meet NFPA and UL 520Hz requirements for sleeping areas making them ideal for new construction or retrofits. EGOS Series speakers produce crisp, clear voice audio output that is highly intelligible over large areas. In an emergency, intelligibility is critical to life safety. Understanding the content of the message is as important as knowing there is an emergency. Intelligibility is measured in Speech Transmission Index and anything above .76 is considered excellent. EGOS Series speakers deliver audio with an ST1 of .81 ensuring the message is clear. Serviceability is another area where EGOS Series appliances shine. The universal room side wiring plate allows for pre- instalation and electrical wiring as well as checking continuity with the included diagnostics check bar. EGOS Series devices can then be easily snapped into place with the confidence of knowing the Wring is correct. The innovative under-cover diagnostic test points provide easy access to device circuit testing while mounted. Page 1 of 6 DATA SHEET K85001-1025 Not to be used for instaUhon purposes, Issue 1.1 Standard Features High Fidelity performance with excellent STI - Increased sound fidelity and audio intelligibility with an STI rating of .81 (More than .76 is excellent) Low Frequency (5201-11z) capable - Low frequency output meets NFPA standards for newly constructed commercial sleeping areas High Performance LED Strobe Technology - Ultra low device current consumption allows: - More devices per circuit - Ability to use lower gauge wire - Longer wire runs - Fewer booster power supplies - High efficiency optics - Selectable 15, 30, 75, or 115 cd light output - LED devices may be mixed with legacy Xenon strobes on the same circuit and in the same field of view Field flexibility - Speakers are also capable of both 25V and 70V and voltage in a single model with a field selectable switch - Speakers feature selectable wattage taps for '/4W, ½W, 1W, and 2W to configure sound output levels in the field Low-profile Design - Ultra-slim.., protrudes about 1.5 from the mounting surface - Attractive appearance... no visible mounting screws Multiple FIRE" Marking Options - Order English, French, Spanish or no FIRE markings - Change markings at any time with replaceable quick-swap covers Easy to Install - Pre-install and pre-wire with convenient universal room side wiring plate - Check electrical continuity on room side wiring plate with included diagnostics check bar - Diagnostics port streamlines device circuit testing - Fits 2-gang and 4-inch square electrical boxes - Optional red and white trim plates available - Slide switches for field configuration - 12 to 18 AWG in-out screw terminals for quick wiring Current draw is the same for all candela output settings - Easier for new system design - Flexible for future changes in light output needs Application Strobes Genesis EGCS Series strobes are UL 1971-listed for use indoors as wall or ceiling public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87 dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act. Synchronization is important in order to avoid triggering seizures in people with photosensitive epilepsy. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. See the specifications table for a list of compatible sources. Speakers The suggested sound pressure level for each signaling zone used with alert or alarm signals is a minimum of 15 dB above the aver- age ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater. This is measured 5 feet (1.5 m) above the floor. Doubling the distance from the signal to the ear will theoretically cause a 6 dB reduction in the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. Doubling the power output of a device (e.g.: a speaker from 1W to 2\M will increase the sound pressure level by 3dBA. High Fidelity Sound Genesis LED EGCS Series High Fidelity appliances feature 87dB of sound output along with a highly intelligible Speech Transmission Index (STI) rating of .81. An STI rating above .76 is considered excellent for speech intelligibility They are also effective in areas subject to high levels of ambient noise. These appliances are ideal for hotels, dormitories and other residential occupancies that have sleeping areas that require 520Hz tones. In sleeping areas, always ensure that the wattage tap of the speaker is set sufficiently high so that the sound pressure reaches at least 75 dBA at the pillow. These appliances are part of an end-to-end audio system approved for use in sleeping areas when used in conjunction with approved audio hardware and a factory-supplied 520 Hz tone. Check the System Compatibility List for other 520 Hz signaling requirements. Installation Genesis EGCS speakers and speaker-strobes mount to the required GRSW room side wiring plate. The GRSW mounting plate is included with the device for convenient pre-installing and pre-wiring. The device can be removed easily from the room side wiring plate by pushing up with a screwdriver. The cover can also be removed from the device easily with a screwdriver to access the light and sound output settings and a diagnostics test port for voltage testing. Genesis LED EGCS Series speakers and speaker-strobes mount to any standard two-gang and 4-inch square electrical box. Matching optional EGCT trim rings are available to cover oversized openings. Optional color matched double-gang surface boxes are also available. Page 2 of 6 DATA SHEET K85001-1025 Not to be used for nstaIIaton purposes Issue 1.1 In R" EGCT Trim Plate (optional) 0.3" (0.76 cm) Speaker + Circuit In - Strobe 4 Circuit In - Wiring ding Clip Speaker Circuit Out Strobe Circuit Out Dimensions EGCS Notification Appliances 1.82" (4.62 cm) 6.8" (17.27 cm) Installation Electrical Box (1] L41 (2),,,,_ I I (4)1 (5 ), 1) Electrical box Trim plate (optional) Wiring plate (required, ordered separately) Machine screw (2X, supplied with wiring plate) Notification appliance Removing Cover Removing Device Test points indicated above are used to validate the Notification Appliance Circuit and verify device function. Page 3of6 - DATA SHEET K85001-1025 Not to be used for installation purposet Issue 1.1 Diagnostics Strobe Circuit Test Points Speaker Circuit Test Points Vertical -6 dBA Field Configuration 120° and 600 -3 dBA 145° and 40° Horizontal Left 10 25 30 fu 35 40 45 so 55 fT 75 an 85 so 75 70 65 60 45 55 40 Measured — — — UL Minimum Vertical Bottom Operating current Strobes -Strobe setting 16to33VDC 16to33VFWR 15,30,75,115 35 m 45 m Note: Current draw is the same for all candela settings Sound Level Output Voltage Wattage Reverberant Anechoic (CAN/ setting setting (UL 1480) ULC-S541) 1/4W 78 77 ½ W 25V/ 70V 81 80 1W 84 83 2W 87 86 Sound Output Sound pattern (ULC) Axis Angle Change in output Horizontal 120° and 600 -3 dBA 140° and 40° -6 dBA Genesis LED speakers are capable of both 25V and 70V operation depending on the system, The voltage is set via a switch under the cover. Speakers also may be set for 1/4,1/2, 1, or 2 watt operation. The wattage setting is visible through a small window on the side of the device and is changed by simply sliding the switch under the cover until the desired setting appears in the window. The speaker does not have to be removed to change the wattage, only the cover skin. Genesis LED clear strobes and speaker-strobes may be set for 15, 30, 75, or 115 candela output. The output setting is changed by simply removing the cover and sliding the candela switch to the desired setting. The device does not have to be removed from the wall to change the output setting. The setting remains visible through a small window on the left-hand side of the device after the cover is closed. Light and Sound Output Settings Light Output Setting (Candela) Sound Settings (Watts and Volts) Light Distribution Page 4of6 -- DATA SHEET K850011025 Not to be used for installation ourposes. Issue 1.1 Ordering Information rena1Iromwj1IIIlI.(w. Color '1iiiEs Aeplacement Appliance Covers Color Marking EGCSRF Red FIRE EGCSRF-CVR Red FIRE 40 EGCSRN-CVR Red None EGCSRN Red None EGCSWF White FIRE EGCSWA-CVR White ALERT Speakers EGCSWN White None Speakers EGCSWF-CVR White FIRE EGCSWA White ALERT Covers EGCSWN-CVR White None EGCSVRF Red FIRE EGGSVRF-CVR Red FIRE EGCSVRN Red None EGCSVRN-CVR Red None EGCSWIF White FIRE EGCSVWA-CVR White ALERT Speaker- EGCSW/N White None speakers- EGCSVWF-CVR White FIRE strobes EGCSVWA White ALERT strobe COIS EGCSW/N-CVR White None Accessories Room Side Wiring Trim plate, EGC Series, EGCTW Trim plate, EGG Series, GRSW Plate (required and EGCTR red white included with device) 0 27193-21 Two-gang surface 27193-26 Two-gang surface mount box, red mount box, white Model Number Syntax, Appliances - Genesis Series EGCS = Ceiling mount appliances F Housing Color R = Red W = White 7-1 'EGCiSVRF Housing Marking L..._J N = None * ALERT Marking I F = FIRE available on white L A = ALER ly strobe model on Functions See replacement S = Speaker only covers for more V = Strobe only options. SV = speaker-Strobe Model Number Syntax, Replacement Covers ,- Genesis Series EGCS = Ceiling mount appliances F Housing Color R = Red W = White 'EGdSVRF-CVR Cover I Cover Marking I N=None Functions F = FIRE S = Speaker only A=ALERT V = Strobe only SV = Speaker-Strobe Page 5of6 DATA SHEET K850011025 Not to be used for nstalLaton purpose: Issue 1.1 105 100 9s go Specifications Strobe operating voltage 16 to 33 VDC, 16 to 33 VFWR Speaker operating voltage 25VRMS of 70VRMS (selectable) Speaker frequency response 4001-1z - 4,0001-1z (UL rateo Speaker frequency response 100Hz - 11,0001-1z (nominal) Ught output 15, 30, 75, or 115 candela Strobe flash rate 1 fps (flash per second) approx. 20 U max. between any two devices. To Synchronization determine allowed wire resistance, refer to these specifications, and the specifications for the synchronized signal source. Kidde CC Series Signal Modules, Booster Synchronization Sources and Auxiliary Power Supplies, Intelligent and Conventional Control Panels Wire size 12 to 18 AWG (0.75 to 2.50 mm') Dimensions (0 x D) 6.8 x 1.82 in (17.27 x 4.62 cm) Strobe-to-box center offset -1.70 inches (-4.32 cm) Compatible electrical boxes [1] 2-gang, 4-inch square Trim plates EGCTR, EGCTW 10.6 x 0.3 in. (26.92 x 0.76 cm) Operating environment Temperature 32 to 122°F (0 to 50°C) Relative humidity 0 to 93% noncondensing Storage Temperature -40 to 158 F (-40 to 70 C) RALr' I Color Red=RAL3O13 White=RAL 9002 Environmental compliance RoHS directive 2011/65/EU fKidde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-esfire.com Kidde is a Carrier brand. 8985 Town Center Pkwy, Bradenton, FL 34202 © 2021 Canter All rights reserved. - ni_____ son - 4!!—• a no I ME -MOM WO =0 - - -._ ---- - 100 1000 10000 f(HzJ Typical Frequency response @ 1W/1m Page 6of6 - DATA SHEET K85001-1025 - Not to be used for installaton purposes. Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL M FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0510 Pagel of 2 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Edwards Models GCV, GCVWF, GCVWF-SP, GCVRF-SP, GCVWF-FR, GCVRF-FR, GCVRF, GCVWN, GCVRN, *GCV* *GCV*F *GCV*F..FR *GCV*F..SP and *GCF*N indoor wall/ceiling mounted strobes. Edwards Models GCVWA and *GCV*A indoor wall mounted strobes. Kidde Models EGCV, EGCVWF, EGCVRF, EGCVRN, EGCVWN, *EGCV* *EGCV*F and *EGCV*N indoor wall/ceiling mounted strobes. *For models with an Asterisk *: The * can be any 3 digit alphanumeric or all numeric characters used to designate custom cover color option other than red or white. The basic differences between each model are as follows: - GCV base model for strobe - Suffix WF white enclosure with FIRE marking - Suffix RF red enclosure with FIRE marking - Suffix WN white enclosure with no marking - Suffix RN red enclosure with no marking - Suffix FR marking is FEU - Suffix SP marking is FUEGO - Suffix WA white enclosure with ALERT marking - Prefix E designates brand as KIDDE instead of EDWARDS Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 Vdc/fwr Candela 15cd, 30cd, 75cd, 115cd selectable INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Models beginning with G are marked Edwards. *Revision 05-12-20 VMN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed t\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7125-1657:0510 Page 2 of 2 Models beginning with E are marked Kidde. APPROVAL: Listed as a strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. The lights are only considered synchronized when used in conjunction with Listed Model GIM-RM (CSFM listing No. 7300-1657:0201) or Model SIGA-CC1S (CSFM listing No. 7300-1657:0121). Refer to listee's Installation Instruction Manual for details. *Revision 05-12-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division 100 J-k"r Kl*dde Technology that saves lives Genesis LED EGO Series Ceiling Mount Notification Devices Overview Genesis LED EGO Series horns and LED strobes feature a sleek low profile design and energy-efficient technology that makes them less expensive to install and operate by reducing overhead. High performance LEDs require fewer power supplies, backup power, and batteries. These new appliances are designed with, energy-efficiency, and life safety in mind. Genesis LED EGO Series uses high efficiency optics, combined with patented electronics, to deliver a highly controlled and efficiently focused light distribution pattern in exchange for lower current requirements. Strobes feature field-selectable 15, 30,75, or 115 cd light output. Compared with Xenon-type strobes, Genesis LED EGO Series appliances need fewer power supplies and often smaller wire gauge, which lightens conduit requirements. They are also backwards compatible with legacy strobes, so there's no need to replace all your existing devices to upgrade to new LED technology. In fact, EGC strobes can be mixed on the same circuit and used in the same field of view as Xenon-based strobes. This makes Genesis LED EGO Series ideal for new installations and retrofits alike. Field-configurable sound output levels provide the flexibility modern life safety projects demand, while the Genesis LED control protocol keeps multiple strobes on compatible NAC circuits synchronized to well within NFPA 72 requirements. Serviceability is another area where EGG Series appliances shine. The universal room side wiring plate allows for pre-installation and electrical wiring as well as checking continuity with the included diagnostics check bar. EGO Series devices can then be easily snapped into place with the confidence of knowing the wiring is correct. The innovative under-cover diagnostic test points provide easy access to device circuit testing while mounted. Page 1 of 6 K DL ' Strobes, Horns, Bells, Chimes >;• Ilk :•:•:•:•:.:•: :V $218, ........ . $5389 ........ 71257:0510 FC Standard Features High Performance LED Strobe Technology - Ultra low device current consumption allows: - More devices per circuit - Ability to use lower gauge wire - Longer wire runs - Fewer booster power supplies - High efficiency optics - Selectable 15, 30, 75, or 115 cd light output - LED devices may be mixed with legacy Xenon strobes Efficient Audible Output - Selectable high or low dB horn output - Selectable temporal or steady horn output - Improved audio frequency range for better wall penetration Low-profile Design - Ultra-slim.., protrudes about 1.5" from the mounting surface - Attractive appearance... no visible mounting screws Multiple Marking Options - Order Red or White with or without FIRE markings - Change markings at any time with replaceable quick-swap covers Easy to Install - Pre-install and pre-wire with convenient universal room side wiring plate - Check electrical continuity on room side wiring plate with included diagnostics check bar - Diagnostics port streamlines device circuit testing - Fits 1-gang, 2-gang, 4-inch octagon, and 4-inch square electrical boxes - Optional red and white trim plates available - Slide switches for field configuration - 12 to 18 AWG in-out screw terminals for quick wiring DATA SHEET K85001-1021 Not to Dc used for nstallaton purpos Issue 1.1 Genesis LED EGO Series horns, strobes, and horn-strobes mount to any standard one-gang, two-gang, 4-inch octagon, and 4-inch square electrical box. Matching optional EGCT trim rings are available to cover oversized openings. Optional color matched double-gang surface boxes are also available. Genesis LED EGO series are listed to be both wall mounted or ceiling mounted. Electrical Box Trim Plate (optional) wiring plate (required, included with device) Machine screw (2X, supplied with wiring plate) EGC signaling appliance Wiring Horn/strobe circuit in (signal polarity shown in the active condition) + Horn/strobe - circuit out Shorting Clip Application Strobes Genesis EGC Series strobes are UL 1971-listed for use indoors as ceiling-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87 dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act. Synchronization is important in order to avoid triggering seizures in people with photosensitive epilepsy. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. See the specifications table for a list of compatible sources. Horns Genesis horn output reaches as high as 92 dBA and features an improved audio frequency range compared with other Genesis horns. This results in excellent sound penetration through walls and a clear warning of danger. Horn only models may be configured for either coded or non-coded notification appliance circuits. They can also be set for high or low dBA output. This setting reduces horn output by about 6 dBA. The suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dBA above the average ambient sound level, or 5 dBA above the maximum sound level having a duration of at least 60 seconds, whichever is greater. These values are measured at five feet (1.5 m) above the floor. The average ambient sound level is A-weighted, fast response sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dBA reduction of the received sound pressure level. The actual effect depends on the acoustic environment in the space. A 3 dBA difference represents a barely noticeable change in volume. Installation Genesis EGC horns and strobes mount to the required GP1 0 room side wiring plate. The GP1 0 mounting plate is included with the device for convenient pre-installing and pre-wiring. The device can be removed easily from the room side wiring plate by pushing up with a screwdriver. The cover can also be removed from the device easily with a screwdriver to access the light and sound output settings and a diagnostics test port for voltage testing. Removing cover Removing Device Page 2 of 6 DATA SHEET K85001-1021 Not to be used tor nitalIation purposes, Issue 1.1 0.3" (0.76 cm) Diagnostics Constant, low dB Constant, high dB T3 temporal, low dB T3 temporal, high dB (5)115 candela (6)75 candela (7) 30 candela (8)15 candela Dimensions EGC Notification Appliances 1.82" (4.62 cm) EGCT Trim Plate (optional) Field Configuration Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. By sliding the tone selector switch, 6.8" horn only models may be configured for constant horn output that (17.27 cm) - can be coded at precise intervals by KIDDE control panels and control modules. Note: Temporal 3 coding is the required output for fire notification devices per NFPA 72. Any device coding other than temporal 3 is at the discretion and approval of the local authority having jurisdiction (AHJ). Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by sliding the tone selector switch. This reduces the output by about 6 dBA. Genesis LED clear strobes and horn-strobes may be set for 15, 30, 75, or 115 candela output. The output setting is changed by simply removing the cover and sliding the candela switch to the desired setting. The device does not have to be removed from the wall to change the output setting. The setting remains visible through a small window on the device after the cover is closed. Light and Sound Output Settings Operating current Horns Strobes Sound 16to33 16t033 setting VDC VFWR Strobe setting 16t033 16t033 VDC VFWR C-Low, 20 mA 25mA T-Low 15, 30, 75,115 35 MA 45 mA C-High, 30 mA 40 mA 1gh______ o .. Horn-Strobes Test points indicated Strobe above are used to validate ______ setting Sound setting _ 16 to 33 VDC 16 to 33 VFWR _____ the Notification Appliance 15,30, C-Low, 1-Low 50 mA 60 mA _____________________________ Circuit and verify device function. 75,115 _ C-High, T-High 60 mA 75 mA__________________________________________ Page 3 of 6 DATA SHEET K85001-1021 Not to be uiod for instaVation purposs. Issue 1.1 Sound Output Horn & Horn-Strobe Sound SttIfl9 Reverberant Anechoic (UL464) (CAN/ULC - S525) C-Low, T-Low 80 dBA 86 dBA C-High, T-High 86 dBA 92 dBA Sound pattern - Horn Models (ULC) Axis Angle (°) Output (dBA) Horizontal 115 and 55 93.3 Vertical 125 and 50 91.7 Sound pattern - Horn-Strobe Models (ULC) Axis Angle (°) Output (dBA) 145 and 35 93.0 Horizontal 155 and 35 90.8 135 and 35 92.0 Vertical 155 and 25 85.4 Light Distribution 1/ Horizontal Left 25 20 30 35. 40 45 / 50 so 75 80 as 85 80 75 '5I35 ILJllJJ 2025 15 10 0 10 15 Vertical Bottom Measured - - - UL Minumum 15 10 0 Horizontal Right 10 15 20 25 1/1,1 30 ,3545 / 550 55 6 66 70 75 80 - 85 90 -. 85 80 75 70 65 60 50 45 40 35 Specifications 16 to 33 or TC3 temporal or 115 candela Strobe flash rate 1 fps (flash per second) approx. Synchronization 20 U max. between any two devices. To determine allowed wire resistance, refer to these specifications, and the specifications for the synchronized signal source. Synchronization Sources Kidde CC Series Signal Modules, Booster and Auxiliary Power Supplies, Intelligent and Conventional Control Panels Wire size 12 to 18 AWG (0.75 to 2.50 mm2) Mounting Wall or Ceiling mount Dimensions (0 x D) 6.8 x 1.82 in. (17.27 x 4.62 cm) Strobe-to-box center offset -1.70 inches (-4.32 cm) Compatible electrical boxes [1] 1-gang, 2-gang, 4-inch octagon, 4-inch square Trim plates EGCTR, EGCIW 10.6 x 0.3 in. (26.92 x 0.76 cm) Operating environment Temperature Relative humidity 32 to 122°F (0 to 50°C) 0 to 93% noncondensing Storage Temperature -40 to 158 F (-40 to 70 C) (1] Dectrical boxes must be at least 1-1/2 in. (3.81 cm) deep. Page 4of6 - DATA SHEET K85001 1021 Not to be used for onstaltation purposes. Issue 1.1 EGCVRF EGCVRN EGCWJF Strobes EGC'mN EGCAVRF EGCAVRN EGCAVWF Horn-strobes EGCAVWN Red FIRE EGCVRF-CVR Red FIRE None ;W EGCVWA-CVR White ALERT FIRE EGCVWF-CVR White ARE Strobe None Covers EGCW/N-CVR White None FIRE ' EGCAVRF-CVR Red FIRE None EGCAVWA-CVR White ALERT FIRE • EGCAW/F-CVR White FIRE None HorCovers n-strobe EGCAWVN-CVR White None Red White White Red Red White White Model Number Syntax, Appliances i— Genesis Series EGC = Ceiling mount appliances F Housing Color R = Red W White EGCAVRF Housing Marking L_J N = None Functions F FIRE A = Horn only V = Strobe only AV = Horn-Strobe Model Number Syntax, Replacement Covers r- Genesis Series EGC = Ceiling mount appliances F Housing Color R = Red W=White 'EGdAvRF-cvR g::nation Li_i I Housing Marking I N=None L.... Functions F = FIRE A= Horn only A=ALERT V = Strobe only AV = Horn-Strobe Ordering Information EGCARF Red FIRE Horns EGCAWF White FIRE • EGCARF-CVR Red FIRE EGCAWA-CVR White ALERT EGCAWF-CVR White FIRE Horn Covers EGCAWN-CVR White None Accessories EGCTR Trim plate, EGC Series, EGCTW Trim plate, EGC Series, GP1 red white Room Side Wiring Or Plate (required, included with device) GSRW-10 27193-21 Two-gang surface 27193-26 Two-gang surface mount box, red mount box, white Page 5of6 DATA SHEET K850011021 Not to b u5ed tor nstallation purposes Issue 1.1 1,. fr Kidde Technology that saves lives Contact us Phone: 888.244.9979 (Option 4) Email: kidde.fire@carrier.com Website: kidde-esfire.com Kidde is a Carrier brand. 8985 Town Center Pkwy, Bradenton, FL 34202 © 2020 Carrier All rights reserved. Page 6 of 6 DATA SHEET K85001-1021 Not to be used for onstallat on purpose-. Issue 1.1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0510 Pagel of 2 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@camer.com DESIGN: Edwards Models GCV, GCVWF, GCVWF-SP, GCVRF-SP, GCVWF-FR, GCVRF-FR, GCVRF, GCVWN, GCVRN, 'GCV*, *GCV*F *GCV*F.FR *GCV*F..SP and *GCF*N indoor wall/ceiling mounted strobes. Edwards Models GCVWA and *GC%,/*A indoor wall mounted strobes. Kidde Models EGCV, EGCVWF, EGCVRF, EGCVRN, EGCVWN, *EGCV* *EGCV*F and *EGCV*N indoor wall/ceiling mounted strobes. *For models with an Asterisk u*: The * can be any 3 digit alphanumeric or all numeric characters used to designate custom cover color option other than red or white. The basic differences between each model are as follows: - GCV base model for strobe - Suffix WF white enclosure with FIRE marking - Suffix RF red enclosure with FIRE marking - Suffix WN white enclosure with no marking - Suffix RN red enclosure with no marking - Suffix FR marking is FEU - Suffix SP marking is FUEGO - Suffix WA white enclosure with ALERT marking - Prefix E designates brand as KIDDE instead of EDWARDS Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 Vdc/fwr Candela 15cd, 30cd, 75cd, 115cd selectable INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Models beginning with G are marked Edwards. *Revision 05-12-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division Listing No. 7125-1657:0510 Page 2 of 2 Models beginning with E are marked Kidde. APPROVAL: Listed as a strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. The lights are only considered synchronized when used in conjunction with Listed Model GIM-RM (CSFM listing No. 7300-1657:0201) or Model SIGA-CCIS (CSFM listing No. 7300-1657:0121). Refer to listee's Installation Instruction Manual for details. *Revision 05-12-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2022 Listing Expires June 30, 2023 Authorized By: VICTOR WONG, Program Coordinator Fire Engineering Division