HomeMy WebLinkAboutPRE 2024-0016; ROOSEVELT CONDOS; Admin Decision Letter□FILE April 15, 2024 RANDOLF CHEREWICK 2033 SAN ELIJO AVENUE #423 CARDIFF, CA 92007 SUBJECT: PRE 2024-0016 (DEV2024-0033) -ROOSEVELT CONDOS APN 203-102-37-00 Dear Mr. Cherewick, (city of Carlsbad Thank you for submitting a preliminary review application for a proposed three-story mixed-use, airspace condominium project. The proposed development consists of the following: • Two (2) three-story buildings with two (2) roof decks separated by a 24-foot-wide private drive- aisle. • Ground-floor commercial retail/office space divided into two (2) for-sale units fronting Roosevelt Street. Commercial unit sizes are described as follows: ► Unit 1A = 499 sq. ft. ► Unit 1B = 608 sq. ft. • Six (6) for-sale residential condominium units at 30 dwelling units per acre (6 units+ 0.2 acres= 30 du/ac). Residential unit sizes are described as follows: ► Unit 2A: 2 bed/2 bath, 1175 sq. ft. ► Unit 2B: 2 bed/2 bath, 1175 sq. ft. ► Unit 3A: 2 bed/2 bath, 1250 sq. ft. ► Unit 3B: 2 bed/2 bath, 1250 sq. ft. ► Unit 4A: 4 bed/3 bath, 2862 sq. ft. ► Unit 4B: 4 bed/3 bath, 2862 sq. ft. • Eight (8) garage parking spaces consisting of two (2) 2-car garages and four (4) one-car garages. • Two (2) open/surface parking spaces. The project site, an approximately 8,712 sq. ft. (0.2-acres) lot, is located at 2650 Roosevelt Street and currently is developed with a one-story single-family residence that is proposed to be demolished as part of the development project. The project is proposing to implement State Density Bonus Law and is requesting parking reductions pursuant to Assembly Bill (AB) 2097. In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans, policies. and standards in effect as of the date of this review. Please Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 {DEV2024-0033)-ROOSEVELT CONDOS April 15, 2024 Page 2 be aware that at the time of a formal application submittal, new plans, policies. and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: General 1. General Plan and zoning designations for the property are as follows: a. General Plan: V-8, Village-Barrio b. Zoning: Village-Barrio (V-8) Zone c. Master Plan: The project site is located within the Village General {VG) District of the Carlsbad Village & Barrio Master Plan (VBMP). Mixed-use residential with ground floor retail or office is permitted in the VG District. 2. The project requires the following permits: a. Tentative Tract Map (CT). A CT is required for an eight {8) unit air-space condominium map consisting of six (6) residential units and two (2) retail/office units. b. Site Development Plan (SDP). An SDP is required pursuant to the provisions outlined within Section 6.3.3{8) of the VBMP (p. 6-4). Per the VBMP the City Council is the decision maker for the SDP. Together, the CT and SDP will require a recommendation from the Planning Commission and approval by the City Council at separate public hearings. 3. The following technical studies/reports, beyond those listed as required in Development Permit Application Form P-2, shall be required with a formal submittal. Each of the studies/reports shall be provided in hardcopy (2 copies each) and digital (.pdf) formats: a. Biological Resources Survey/Site Report. The biological resources survey/site report shall be prepared by a certified biologist, indicating location and quantities of all habitat and vegetation on the property consistent with the city's Habitat Management Plan (HMP). b. Historical, Cultural and Paleontological (three {31 separate reports\. The development of the proposed project will require demolition and excavation in an area of the city known to have a high sensitivity as it relates to (1) architectural history, (2) archeological resources, and {3) paleontological resources. Please direct your consultant to the city's Tribal, Cultural and Paleontologicol Resources Guidelines. Please note that any archeological pedestrian survey of the site for the cultural resources study shall also include a Native American monitor during the survey. The city's Tribal, Cultural and Poleontological Resources Guidelines may be found on the city's website at: https:ljwww.carlsbadca.gov/home/showpublisheddocument/254/637425976516870000 Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033)-ROOSEVELT CONDOS April 15, 2024 Pa e 3 This does not represent an exhaustive list. Additional studies may be required based on results of the above studies and also other studies being requested by the reviewing City Departments and Divisions listed below. 4. The Housing Crisis Act of 2019 (SB 330) established a preliminary streamline application process for housing projects. It is not mandatory unless applicants seek the vesting and processing benefits offered under SB 330. Participation in the SB 330 streamline process would occur first, followed by the formal development application process required under Government Code (Gov. Code)§§ 65940, 65941, 65941.5, and Carlsbad Municipal Code (CMC) § 21.42.050. Acceptance by the city of a complete SB 330 Streamline Application (Form P-32) and fee will vest the project for 180 days in accordance with the ordinances, policies, and standards in effect at the time the SB 330 Application is accepted. 5. Per the Housing Crisis Act of 2019 (SB 330), any project that includes the removal or demolition of a "protected unit" is required to provide the occupants with 1) relocation benefits (Gov. Code§ 7260 et seq.), and 2) right of first refusal for a comparable unit available in the new housing development. (Gov. Code § 66300 (d)(2)(D).) "Protected units" are generally defined by Gov. Code § 66300(d)(2)(E)(ii) as including residential units subject to affordability restrictions, price controls, or occupied by low income households. The formal submittal of the project will need to include documentation regarding any existing "protected units." 6. New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely impact development requirements of this project. A formal application submittal will need to include a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management requirements, as set forth in the California Green Building Standards Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following address: http://www.qcode.us/codes/car1sbad/view.php?topic=18&frames=on To the extent that new GHG reduction requirements are in effect at the time of application for grading or building permits, the project will be required to comply with the effective requirements even if different than what is proposed in the project's planning approvals. GHG reduction requirements may impact, but are not limited to, site design and local building code requirements. If incorporating new GHG reduction requirements results in substantial modifications to the project after planning approvals are obtained, then prior to issuance of grading or building permits, the applicant may be required to submit and receive approval of a Consistency Determination or an Amendment application for the project through the Planning Division. 7. The preliminary review exhibits, specifically Sheet T.1, refers to accessory dwelling units (AD Us) within the density calculation; however, no ADUs are proposed within the floor plan exhibits and therefore should not be included in any part of the application or density discussions. (See Housing & Homeless Services comments below for additional details regarding density, density bonus and affordable housing requirements.) Community Development Department Planning Division \ 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033) -ROOSEVELT CONDOS April 15, 2024 Pa e4 8. The project is requesting parking reductions pursuant to Assembly Bill (AB) 2097. Please be aware, irrespective of proximity to public transit, state law allows the city to continue to apply minimum parking standards for electric vehicle (EV) charging stations as well as required parking spaces accessible to persons with disabilities (ADA). The proposed project site plan does not provide either and will need to be revised to accommodate requirements. (See Building Division comments below for additional details and requirements.) 9. Pursuant to AB2097, the city may require that the voluntary parking spaces meet established minimum location and design standards. As such, staff is providing the following comments: a. The minimum width of aisles that provide access to parking spaces with 90 degree parking is 24 feet wide. Additional width may be required for vehicle/emergency vehicle maneuvering. (CMC Section 21.44.050, Table B). With a formal submittal, please be sure to dimension the width of the proposed drive-aisles leading to each garage and open parking space. b. The two open parking spaces located towards the rear of the property are required to provide a minimum area of 170 square feet and a minimum width of 8.5 feet. (CMC Section 21.44.050, Table B). With a formal submittal, please dimension all proposed parking stalls to comply. c. Required uncovered parking spaces may be located within the side and/or rear yard setback, provided that a six-foot-high masonry wall (or some other solid material approved by the decision- making authority) is built along the property line adjacent to the setback area. (CMC Section 21.44.060, Table C). With a formal submittal, please plot and identify said screening, height, and materials. d. For two-car garages, the minimum interior dimensions are required to be 20 feet by 20 feet. (CMC Section 21.44.060, Table D). Please revise the proposed site plan to accommodate said minimum requirements, where applicable please dimension each garage space as it relates to the interior dimension. Please note that any proposed storage cabinets, trash can alcoves, hot water heaters, HVAC, laundry, etc. shall be located outside of this minimum interior dimensional space. Overhead, ceiling mounted, garage storage is permissible. e. For one-car garages, the minimum interior dimensions are required to be 12 feet by 20 feet. (CMC Section 21.44.060, Table D). Please revise the proposed site plan to accommodate said minimum requirements, where applicable please dimension each garage space as it relates to the interior dimension. Please note that any proposed storage cabinets, trash can alcoves, hot water heaters, HVAC, laundry, etc. shall be located outside of this minimum interior dimensional space. Overhead, ceiling mounted, garage storage is permissible. 10. The project frontage along Jefferson Street currently includes two curb cuts into the site and may have adequate space for one parallel parking space between. With the proposed development, namely the addition of a central drive aisle, it may be possible that two parallel parking spaces may be accommodated on each side of the drive aisle. With a formal submittal, please update the site plan to identify all parallel parking spaces that can be accommodated across the project frontage. Parallel parking space dimensional requirements are as follows (CMC Section 21.44.050, Table B): Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033)-ROOSEVELT CONDOS April 15, 2024 Pa e 5 • Minimum length of 24 feet, exclusive of driveway/drive-aisle entrances and aprons. • Minimum length of 20feet if located immediately adjacent to a driveway/drive-aisle apron. • Minimum width of 7 feet. 11. No architecture was included with this preliminary review submittal; therefore, no comments regarding architectural design and zoning conformance is being provided. Please be aware this project is subject to the City's recently adopted Village & Barrio Objective Design Standards (ODS). Please find additional information about the Village & Barrio Objective Design Standards below. https://www.carlsbadca.gov/departments/community-development/planning/village-barrio- objective-design-standards 12. Conceptual landscape exhibits are required and shall be prepared in accordance with the General Requirements listed in Section 3 of the City of Carlsbad Landscape Manual (February 2016). The Landscape Manual may be found on the city's website at: https://www.carlsbadca.gov/home/showpublisheddocument/234/637425974086270000 13. Mixed-use is permitted within the VG District per the VBMP, Table 2-1. For an exhaustive list of uses permitted, conditionally permitted, and/or prohibited in the VG District, please consult Table 2-1 beginning on page 2-6 of the VBMP. For an exhaustive list of expressly prohibited uses, please see Table 2-1 on page 2-8. 14. This project is subject to the Chapter 2.6 Area-Wide Standards of the VBMP beginning on page 2-12. Based on the proposed floor plan exhibits, the project appears to be deficient in the following areas: a. §2.6.1-A. INGRESS AND EGRESS: Where alley access is not available, development sites shall be permitted a maximum of one access point from public street. Driveway apron shall not exceed 20 feet in width. A clear zone shall be provided at the intersection of a street or driveway to maintain a free line of sight. The clear zone shall consist of an isosceles right triangle measured 7.5 feet in both directions from the intersection of the two property lines. The clear zone shall not be occupied by a ground floor building footprint, or site features taller than 36 inches, or landscaping that is taller than 30 inches. Please update plans to address the above requirements. b. §2.6.4-A. GOOD NEIGHBOR: Loading and service areas for commercial uses shall be screened from residential uses and shall not be located within residential parking areas or block access ways to residential areas (§.2.6.4.A4}. Commercial uses with residential units attached shall provide ventilation systems to prevent odors from adversely affecting residential units (§.2.6.4.A6}. Commercial uses with residential units attached or on the same floor as the commercial uses shall feature a site and building design that ensures adequate separation between residential and nonresidential areas and the protection of resident privacy and quiet. This requirement extends to all elements of a project, including but not limited to parking, external and internal building access, floor plan design, and common areas and amenities (§.2.6.4.Al). Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033) -ROOSEVELT CONDOS April lS, 2024 Pa e 6 Please update plans to address the above. Please note that proposed floor plan exhibits currently do not show where or how the commercial tenant spaces will vent through the upper floors, or how the proposed mixed use development intends to address site generated refuse from both the commercial and residential tenants. For the residential uses, if trash can storage is intended to be provided within the garages, then this area needs to be located outside of the minimum interior dimensional requirements. For the two commercial tenant, where will the project's trash enclosure be located. c. §2.6.6-A. PARKING (Table 2-3): For multiple-fomily residential units with two or more bedrooms, 1.5 spaces per unit is required to be provided. For condominiums, one space must be covered. For visitor parking, projects with 10 or fewer units are required to provide 0.30 spaces per residential unit. For retail or business/professional office uses, one space per 415 square feet is required to be provided. Parking requirement calculations resulting in a fraction shall be rounded up to the next whole number if the fraction is 0.5 or higher or rounded down if the fraction is below 0.5. Regardless of the project's intent to utilize AB2097, the required amount of parking per the above city requirements will need to be analyzed and included as part of the proposed project information summary. Please include with your formal submittal a parking summary table that includes all of the proposed uses and required number of parking spaces associated with each proposed use. Please include the total number of parking spaces being proposed, and the total number of parking spaces being waived pursuant to AB2097. (See also Building Division comments below for discussion regarding ADA and EV parking requirements.) 15. This project is subject to the Chapter 2.7.2 -Village General (VG) Supplemental District Standards of the VBMP beginning on page 2-45. The project appears to be deficient in the following areas: a. §2.7.2-A.SETBACKS: Front: Minimum of 5 feet; maximum of 10 feet to building. Additional depth permitted where area includes a plaza, courtyard, or outdoor dining. Additional depth is also permitted to accommodate electrical transformers, utility connections, meter pedestals, and similar equipment only if other locations are infeasible as determined by the decision-maker. Awnings, canopies, upper floor balconies, plazas, courtyards, and outdoor dining are permitted to encroach within the setback up to the property line. Minimum 10 foot landscape setback where surface parking areas are located adjacent to a public street. Side: Minimum of 5 feet Rear: Minimum of 10 feet Please note the above front setback requirements for the VG District, as the proposed preliminary review exhibits differ as listed on the sheet Tl.O. Presently, the exhibits do not to appear to accommodate electrical transformers, utility connections, meter pedestals, and/or other similar equipment. With a formal submittal please address how the project is addressing the location and screening of this critical infrastructure. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033) -ROOSEVELT CONDOS April 15, 2024 Pa e 7 b. §2.7.2 -E. OPEN SPACE: A minimum of 20 percent of property must be mointoined os open spoce. Residential private and common open space may be counted toward achieving the property open space minimum requirement. Open space may be dedicated to landscape planters, open space pockets and/or connections, roof gardens/patios, balconies, other patios, and/or outdoor eating areas. No parking spaces or aisles ore permitted in the open space. (§2.7.2. El.a-d} The preliminary review exhibits note that the lot coverage is 80% for the proposed project, which leaves 20% dedicated to open space. However, the above requirements notes that parking spaces or aisles are not permitted in open space. A formal submittal will need to identify all applicable open space areas in accordance with this requirement. This is generally included as part of the conceptual landscape exhibits and totals are generally noted within the proposed project information summary. c. Residential private open space shall be provided at a minimum of 80 square feet per unit with a minimum dimension of 6 feet in any direction. This requirement may be satisfied by more than one private open space area. (§2. 7.2. E2.a). Proposed Units 3A and 3B appear to be deficient in regard to this private open space requirement. Please update the design to comply. 16. Please be advised that a more in-depth review of the proposed development will occur with the discretionary permit application when a more complete design of the project is provided. All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or online at https:ljwww.carlsbadca.gov/departments/community-development/planning. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown. Please review all information carefully before submitting. Land Development Engineering Division (Nichole Fine): 1. Please contact Nick Gorman in the Traffic Division at Nick.Gorman@carlsbadca.gov, a division of the Public Works Department, to determine if a Scoping Agreement is required. Scoping Agreements are used to determine if a Local Mobility Analysis (LMA) is required and the scope of analysis. Submit either an approved Scoping Agreement or correspondence from the Traffic Division indicating one is not required. Provide average daily trips (ADT) and peak hour trips per generation rates from SAN DAG Brief Guide of Vehicular Traffic Generation Rates for the San Diego Region on the site plan/tentative map. 2. If a Local Mobility Analysis {LMA) is required, please refer to the Transportation Impact Analysis Guidelines available on the city's website at: https://www.carlsbadca.gov/home/showpublisheddocument/328/637425982502330000. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033) -ROOSEVELT CONDOS April 15, 2024 Pa e 8 3. Depending on the CEQA determination, which is determined after the application for discretionary permits is submitted, a Vehicle Miles Traveled (VMT) analysis may be required per the Vehicles Miles Traveled Analysis Guidelines available on the city's website at: https://www.carlsbadca.gov/home/showdocument?id-312. 4. Please complete a Stormwater Standards Questionnaire, Form E-34. This questionnaire will guide you and the city in determining what type of reports and storm water mitigation must be completed to satisfy state and City storm water quality requirements. The questionnaire is located on the City of Carlsbad website. 5. Based on a preliminary analysis it appears that this project may be a Standard Project. Please complete the Standard Project Requirement Checklist, Form E-36, and show all source and site design best management practices (BMPs) on the conceptual grading and drainage plans. 6. Based on this project's General Plan Land Use Designation ofV-B (Village-Barrio), this project is subject to the City of Carlsbad trash capture requirements. Please incorporate trash capture measures on the project plans. Prepare a preliminary Trash Capture Storm Water Quality Management Plan, utilizing the template Form E-35A. 7. Please provide a Preliminary Title Report (current within the last six (6) months). 8. Please annotate and delineate all existing easements and encumbrances listed in the Preliminary Title Report on the site plan. If any vacations or quitclaims are planned with this development, then please annotate on the site plan. 9. A Preliminary Hydrology Study including map and calculations is required to demonstrate capacity/sizing of proposed and existing storm drain infrastructure. Show 100-year storm hydrologic calculations before and after development for each drainage basin. 10. A Preliminary Geotechnical Report is required to evaluate the feasibility of the project and to determine the remedial grading required. Guidelines for preliminary geotechnical studies are available on the City of Carlsbad Engineering website. 11. Per CMC Section 15.16.060 this project will require a grading permit and grading plan. 12. A separate improvement plan for work within the right-of-way is required for this project. 13. This project shall utilize City of Carlsbad Survey Control Network established on Record of Survey Map 17271, NAD83, Zone VI, 1991.35 Epoch for horizontal control and NGVD 29 datum for vertical control per City of Carlsbad Engineering Standards. 14. Please delineate and annotate the limits of grading. Include remedial grading quantities on the plan. 15. Please delineate and annotate approximate topographic contours for existing and proposed condition. Provide 1-foot contours for slopes less than 5%; 2-foot intervals for slopes between 5% and Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033)-ROOSEVELT CONDOS April 15, 2024 Pa e 9 10%, and 5-foot intervals for slopes over 10%. Extend contours a minimum 25 feet beyond the project boundary. 16. On the site plan, please show and identify all existing surface improvements screened back (curb, gutter, sidewalk, paving, manholes, inlets, street lights, adjacent driveways, vaults, transformers, etc.) at the project site, project frontage and within 25 feet of the boundary. 17. Please indicate the earthwork quantities (cut, fill, import, export, remedial) proposed for the project in cubic yards. 18. Please provide spot elevations at the corners of each pad in the proposed condition. Include finish pad and floor elevations. 19. Please provide the method of draining around the buildings. Unless otherwise specified by a Geotechnical Engineer, method of drainage shall comply with California Building Code (latest version) Section 1804.4. 20. Please delineate location of all existing and proposed buildings, walls, fences, and permanent structures onsite and within 25 feet of the site. 21. Please show existing lot line bearing and distance. 22. This project is proposing to create six (6) condominium units and two (2) retail/office spaces. A Tentative Tract Map is required for this development. 23. Please provide typical street cross-section(s) for Roosevelt Street. Provide existing right-of-way width and existing improvements and proposed improvements and dedications. 24. Please delineate and annotate all proposed driveways and driveway widths. 25. Please show all existing utilities and callout size for: water, sewer, storm drain, underground dry utilities, overhead lines, traffic signals, streetlights in Roosevelt Street and laterals affecting the property. 26. All transformers and electrical facilities solely serving this project site shall be located onsite and outside of the public right-of-way. 27. Please provide multiple cross-sections of the site to demonstrate differences in grade from adjacent properties, existing and proposed grades onsite, fences and location of structures onsite and on adjacent properties. 28. Dedications and frontage improvements are required per CMC Chapter 18.40 and/or CMC Chapter 20.16. Roosevelt Street is identified as a Village Street in the Mobility Element of the City of Carlsbad's General Plan. Per Engineering Standards Table A, the street right-of-way is required to be 72-feet wide, with a 36-foot half width. A 3.0 foot and 8.0 foot public street and utility easement shall be dedicated, and public street frontage improvements shall include sidewalk, curb, gutter, and Community Development Department Planning Division I 1635 Faraday Al(enue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033)-ROOSEVELT CONDOS April 15, 2024 Pa e 10 driveway. 29. Please meet with the Fire Department to identify the necessary fire protection measures required for this project (access, fire hydrants, sprinkler system, on-site circulation, emergency access, etc.) 30. Please be advised that a more in-depth review of the proposed development will occur with the discretionary permit applications when a more complete design of the project is provided. Public Works, Utility Design (Markus Mohrlel: 1. Please submit a Water Study Analysis for the project that includes domestic meter and fire sizing criteria, as well as modeling of the public distribution system in response to on-site water demands . per the CMWD 2019 Potable Water Master Plan and applicable NFPA fire flow requirements. Fire sizing in study shall be based on completed Project Facility Availability-Fire (P-99F) Form signed by CFD. 2. Please submit a Sewer Study Analysis for existing and proposed demands for the public sewer main. Note: Commercial and residential units may require separate sewer laterals for compliance with FOG separation. 3. Please update project exhibits to identify all buried utilities in the Roosevelt Street right-of-way along the project's frontage. Existing and proposed utility connections shall be properly located and sized for proposed demands and shall be labeled with current standard detail references. See Attachment 1-Redlines. 4. Proposed Ground floor layout shall preserve suitable locations and space for all required utility connections, meters, and backflow devices in conformance with current Engineering Standards. Identify locations and detail fire service, water, irrigation, and sewer connections at property line for the new development in compliance with 2022 Carlsbad Engineering Design Standards. See Attachment 1-Redlines. 5. Public potable water mains along project frontage(s) must meet minimum design diameter and material as specified in City of Carlsbad Engineering Standard Vol. 2 Section 3.2.2. Utility replacement and upsizing shall be required as a condition of development along project frontage and may require additional extension in the Roosevelt Street right-of-way to nearest properly sized connection point. Housing & Homeless Services (Mandy Mills): 1. Density Bonus Calculation. There is conflicting information in the pre-application submittal. The drawings and scope of work on the plans reflect six residential units. The density calculation on the plans as well as the Preliminary Review Request Form each state a different unit count. Please remove references to other unit counts. Additionally, a technical assistance letter from HCD was included and referenced but is not applicable to this project as no accessory dwelling units are proposed. When a development permit application proposed under Government Code §65915 (state density bonus law) is submitted, the applicant will need to submit the Density Bonus Report (formally known Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033)-ROOSEVELT CONDOS April 15, 2024 Pa e 11 as the Supplemental Checklist) Form P-l(H) Density Bonus Report (carlsbadca.gov). The form will allow confirmation of density calculation, affordable unit count and incentive eligibility. If the application is proposing six residential units, the following density calculation would be used to calculate the density bonus. Acreage: Max Density: Base Units: DB requested 20%: Max: 0.20 23 du/ac 4.6 units= 5 units rounded up 1 unit 6 units Density bonus affordable units required: 1 unit at the low-income level. 2. Density Bonus Compliance Forms. When a development permit application proposed under Government Code §65915 (state density bonus law) includes the demolition of a residential unit, the applicant will need to submit Housing Declarations (Form P-38, Part A and Part B) as part of the application. Part C of this form is to be completed only if required based on the responses to Part A. Where a density bonus project proposes to demolish existing housing, or where rental housing existed on the site in the past five years, the applicant must comply with the replacement housing requirements in State Density Bonus Law. (Government Code Section 65915(c)(3).) A project is ineligible for a density bonus or "any other incentives or concessions" under State Density Bonus Law unless the applicant conforms with any applicable replacement housing requirements. 3. lnclusionary Requirement. The city's inclusionary housing requirement on this site would be satisfied with the one low-income density bonus unit. 4. Affordable Units. The project will be conditioned to record an Affordable Housing Agreement against the property to restrict the pricing and income level of occupants of the low-income unit. Building Division (Mike Strong): 1. The California Building Standards Commission approves and adopts building standards. Every three years, the Commission, in coordination with relevant state agencies, undertakes rulemaking to revise and update the California Building Standards Code (Title 24 of the California Code of Regulations). These building codes serve as the basis for the design and construction of buildings in California. What follows is based on the current regulations, which may change during the processing of your entitlement or submission of construction drawings to implement the project. It is highly recommended that you consult with a CASp design professional to solicit design recommendations prior to the submission of your entitlement package. • Under the California Building Code, accessible parking standards and minimum levels of parking spaces accessible to persons with disabilities must be included in new developments. i) For specified multifamily developments, approximately two percent of assigned parking spaces and five percent of unassigned visitor parking spaces. The required number of handicapped parking shall be in accordance with Table llB-208.2. • Furthermore, under the California Green Building Code, residential parking standards requiring new buildings to provide electric vehicle (EV) parking spaces as follows: 1) New Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0016 (DEV2024-0033)-ROOSEVELT CONDOS April 15, 2024 Pa e 12 single-and two-family dwelling units with attached garages must include infrastructure for EV charging; and 2) multifamily developments must designate at least 10 percent of the total number of parking spaces provided as EV parking spaces. Fire Department {Randy Metz}: 1. Fire Department access is okay as proposed; however, the Fire Department vehicle access is not. The conceptual design will need to be revised prior to formal submittal. If you would like to schedule a meeting to discuss this letter with the commenting departments, please contact Jason Goff at the number below. You may also contact each department individually as follows: • Planning Division: Jason Goff, Senior Planner, at (442) 339-2643 • Land Development Engineering: Nichole Fine, Senior Engineer, at (442) 339-2744 • PW-Utilities Design: Markus Mohrle, Associate Engineer, at {442) 339-2322 • Housing & Homeless Services: Mandy Mills, Director, at {442) 339-2299 • Building Division: Mike Strong, Assistant Com Dev Director, at {442) 339-2721 • Fire Department: Randy Metz, Fire Division Chief, at {442) 339-2661 Sincerely, ERIC LARDY, AICP City Planner EL:JG:cf Attachments: 1. CMWD Redline c: Nichole Fine, Project Engineer Fire Prevention Laserfiche/File Copy Data Entry Community Development Department Planning Division I 163S Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 . .