Loading...
HomeMy WebLinkAbout5928 FARNSWORTH CT; ; AS130015; Permit3/22/24, 10:52 AM Job Address: Permit Type: Parcel No: Lot#: Reference No.: PC#: Project Title: Appl icant: AS130015 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS130015 5928 FARNSWORTH Status: ISSUED CT SPRINK Applied 1/30/2013 2120701000 Approved: 1/31/2013 0 Issued: 1/31/2013 Inspector: CARLSBAD TECH UPGRADE RACKING SPRINKLER Owner: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY MCR FARNSWORTH L L C SAN MARCOS, CA 760-310-6122 about:blank 1808 ASTON AVE #180 CARLSBAD CA Add'I Fee:_(~+-Total ($) 0 268 Balance($) 0 1 /1 02-01-2013 Job Address: Permit Type: Parcel No: Fire Dept Ref#: Location: Project Title: Description: Contractor: City of Carlsbad Fire Department Permit 5928 FARNSWORTH CT CBAD SPRINK Subtype: Tl 2120701000 Lot#: 0 AS130015 Building Permit#: CB130079 CARLSBAD TECH UPGRADE RACKING SPRINKLER EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY Phone: 760-310-6122 Fax: SAN MARCOS, CA 92069 Permit No: AS130015 Status: Applied: Issued: Entered By: PENDING 01/30/2013 CDW Total Fees: $268.00 Total Payments To Date: $0.00 # of Systems # of Additional Risers or Floors Plan Check Fee Additional Plan Check Fee # of Heads Permit Fee Additional Permit Fee Re-Inspection Fee ByPass Meter Fee ByPass Addtl Meter Fee Other Additional Fees TOTAL PERMIT FEES 1 0 2 0 $68.00 $0.00 $0.00 $68.00 $0.00 $132.00 $0.00 $0.00 $0.00 $0.00 $268.00 THIS PERMIT SHALL REMAIN IN THE POSSESION OF THE PERSON OR COMPANY TO WHICH IT HAS BEEN ISSUED. THIS PERMIT SHALL BE AVAILABLE UPON REQUEST OF ANY CITY, COUNTY, STATE OR FEDERAL OFFICIAL FOR REVIEW AND OR INSPECTION NOTICE: Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WA SAN MARCOS, CA 92069 (760) 31 0-6122 FAX (760) 798-0556 Hydraulic Design Information Sheet Name: CARLSBAD TECHNOLOGIES SYSTEM #2 Location: 5928 FARNSWORTH CT. CARLSBAD Date: 1-17-13 Building: EXISTING System No. 2 OF 2 --------Contractor: EPIC FIRE PROTECTION, INC. Contract No. Calculated By: RAB Drawing No. 1 OF 1 --;::::;---------=.-------------------Construction: • IR/ Combustible D Non-Combustible Ceiling Height 26 ------Ft. SYSTEM DESIGN i2J NFPA 13: 0 Light Hazard Ordinary Hazard Group 0 1 □ 2 □ 3 \El Extra Hazard 0 NFPA231 0 NFPA231C: Figure: Curve: D Other (Specify) □Specific Ruling Made By Date Area of Sprinkler Operation 15 HEADS System Type Density 22PSI IZI Wet □ Dry D Deluge D Pre-Action Area Per Sprinkler lO0 SQFTMAX Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make TYCO Model ULTRA 17 Hose Allowance GPM: Outside 500 Size ¾" K-Factor: 16.8 Rack Sorinkler Allowance NA Temperature Rating 200 CALCULATION SUMMARY GPM Required 1226.47 PSI Required 74.31 At Base of Riser ------------------"C" Factor Used: Overhead 120 Under round 150 WATER SUPPLY Water Flow Test Pump Data Tank or Reservoir Date& Time 8-20-12 Rated Capacity Capacity Static PSI 106 At PSI Eleyation Residual PSI 102 Elevation GPMFlowing 1420 Well Elevation 0 Proof Flow GPM Location SITE Source of Information EPIC FIRE AND CARLSBAD MWD COMMODITY STORAGE Commodity SEE TECH REPORT Class I Location Storage Height Area Aisle Width Storage Method: Solid Piled % Palletized %Rack Rack D SingleRow D Conventional Pallet D Automatic Storage D Encapsulated D DoubleRow D Slave Pallet 0 Solid Shelving D Non-Encapsulated D Multiple Row D Open Flue Spacing In lnche~ Clearance From Top of Storage to Ceiling Longitudinal Transverse • Ft. In . Horizontal Barriers Provided \. ::::::- Cl) ll.. -e ::, a, a, ·(I) ... ll.. CARLSBAD TECH SYS#2 15 HEADS AT 22 PS I ULTRA K-17 125 120 115 110 10"5 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 •.. / D~ v-<' / V ~ v· / / / / /, / /, r? ~0 ,._$' / ~v 0200 400 600 800 1000 1200 System Demand .. Sprinkler Demand 85.25 PSI@ Additional Flows °Hose at Source Total Demand 85.25 PSI@ 1226.47 0.00 500.00 1726.47 GPM GPM GPM GPM A\Jn • 1:400 Water Flow'(GPM) -;, r :, I. ' r:: Hol es / Sigma Dynamics Corporation 7700 Supply / Demand Graph I Margin Pressure 4.98 PSI Flow 758.35 GPM ~-• s t 1600 1800 Water Supply .. Stati c 95.40 PSI Residua l 91.80 PS I@ 1420.00 GPM Elevation 0.00 PSI - - N1.as 2000 SUBMITTAL SERIAL NO :2932HY7 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 FLOW TEST RESULTS Water Supply STATIC 95.40 PSI RESIDUAL 91 .80 PSI @ 1420 . 00 GPM CITY PRESSURE AVAILABLE AT 1726.5 GPM 90.23 SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR -------- 350 90.16 78.80 16.80 351 89 .5 0 78 .80 16.80 352 89 .48 78 .80 16.80 356 82 .01 78 .80 16.80 357 79.82 78.80 16.80 358 79.01 78.80 16 .80 359 78.94 78.80 16.80 360 79 .12 78 .80 16.80 361 80 .21 78 .80 16.80 362 81.80 78.80 16.80 3\_63 79.65 78.80 16.80 364 78 .87 78.80 16.80 365 78 .80 78.80 16.80 366 79.00 78.80 16.80 367 80.11 78.80 16.80 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 300 TO 350 PRESSURE -------- 28.80 28.38 2a1.37 23.83 22.57 22.12 22.08 22.18 22.79 23.71 22.48 22.04 22.00 22.11 22.74 1226.47 GPM 500.00 GPM 1726.47 GPM 85.25 PSI 0.00 PSI 31. 58 FPS 01-17-2013 PAGE 1 PSI SUBMITTAL SERIAL NO :2932HY7 01-17 -2013 PAGE 2 CARLSBAD TECH .SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Si,ze & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 315 365 1.080 L 1.25 C=120 PT 22.00 (365) Q 78.80 F=T F . 5.80 PE 0 .54 SG T 7.05 1. 4271 PF 10.06 • PT 32.60 (315 ) ------------------ 317 367 1.080 L 1.25 C=120 PT 22.74 (367 ) Q 80.11 F=T F 5.80 PE 0 .54 SG T 7.05 1.4713 PF 10.37 PT 33.65 (317 ) ------------------ 316 366 1.080 L 1.25 C=120 PT 22.11 (366 ) Q 79.00 F=T F 5.80 PE 0 .54 SG .T . 7 .. 05 1.4337 PF 1 0 .11 PT 32.76 (316 ) ----------------- 314 364 1.080 L 1.25 C=120 PT 22.04 (364 ) Q 78 .87 F=T F 5.80 PE 0 .54 SG T 7.05 1. 4293 PF 1 0 .08 PT 32.66 (314) ------------------ 313 363 1.080 L 1.25 C=120 PT 22.48 (363) Q 79.65 F=T F 5 .80 PE 0 ~,54 SG T 7.05 1. 4557 PF 10.26 PT 33.28 (313) ------------------ 312 362 1.080 L 1.25 C=120 PT 23.71 (362) Q 81. 80 · F=T F 5.80 PE 0.54 SG T 7.05 1.5292 PF 10.78 PT 35.03 (312 ) ------------------ 311 361 1.080 L 1.25 C=120 PT 22.79 (361) Q 80.21 F=T F 5.80 I PE 0.54 SG T 7.05 1.4746 PF 10.40 PT 33.73 (311) ------------------ 310 360 1.080 L 1.25 C=120 PT 22.18 (360) Q 79.12 F=T F 5.80 PE 0.54 SG T 7.05 1.4379 PF 10.14 PT 32.86 (310) ------------------ 309 359 1.080 L 1.25 C=120 PT 22.08 (359) Q 78.94 F=T F 5.80 PE 0.54 SG T 7.05 1. 4317 PF 10.09 PT 32.71 (309) ------------------ 308 358 1.080 L 1.25 C=120 PT 22.12 ( 358) Q 79.01 F=T F 5. 80 · PE 0.54 SG T 7.05 1.4342 PF 10.11 PT 32.77 (308) SUBMITTAL SERIAL NO :2932HY7 01-17-2013 PAGE 3 CARLSBAD .TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI ------------------ 307 357 1.080 L 1.25 C=120 PT 22.57 (357) Q 79.82 F=T F 5.80 PE 0 .54 SG T 7.05 1.4615 PF 1 0 .30 PT 33.41 (307) ------------------ 306 356 1.080 L 1.25 C=120 PT 23.83 (356) Q 82 .01 F=T F 5.80 PE 0 .54 SG T 7 .05 1.5366 PF 10.83 PT 35.20 (306) ------------------ 302 352 1.080 L 1.25 C=120 PT 28.37 (352 ) Q 89.48 F=T F 5.80 PE 0.54 SG T 7.05 1.8053 PF 12.73 PT 41. 64 ( 302) ------------------ 301 351 1.080 L 1.25 C=120 PT 28.38 ( 351) Q 89.50 F=T F 5 .80 PE 0.54 .SG T 7.05 1.8060 PF 12.73 PT 41. 65 (301) ------------------ 300 350 1.080 L 1.25 C=120 PT 28.80 ( 350) Q 90.16 F=T F 5.80 PE 0.54 SG T 7.05 1.8309 PF 12.91 PT 42.25 (300) ------------------ 310 309 2.203 L 8.00 C=120 PT 32.71 (309) Q 48.93 F=0 F 0.00 PE 0.00 BL T 8.00 0.0184 PF 0 .15 311 310DQ 79.12 2.203 L 8.00 C=120 PT 32.86 (310) Q 128.06 F=0 F 0.00 PE 0.00 BL T 8.00 0.1089 PF 0.87 253 311DQ 8(!). 21 2.203 L 11.00 C=l20 PT 33.73 (311) Q 208.26 F=0/T,E F 16.40 PE 0.00 BL T 27.40 0.2677 PF 7.33 254 253DQ -195.27 2.203 L 11. 00 C=120 PT 41. 06 (253) Q 12.99 F=0 F 0.00 PE 0.00 CM2 T 11. 00 0.0016 PF 0.02 255 254DQ 209.75 2.203 L 11.00 C=120 PT 41. 08 (254) Q 222.74 F=0 F 0.00 PE 0.00 CM2 T 11.00 0.3031 PF 3.33 256 255DQ -73.44 2.203 L 11. 00 C=l20 PT 44.41 (255) Q 149.30 F=0 F 0.00 PE • 0. 00 CM2 T 11.00 0.1446 PF 1._59 SUBM ITTAL SERIAL NO :2932HY7 01 -17-2 013 PAGE 4 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length_ Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 257 256DQ -51. 34 2 .203 L 11. 00 C=120 PT 46 .00 (256) Q 97 .97 F=O F 0 .00 PE 0 .00 CM2 T 1 1 .00 0 .0663 PF 0 .73 258 257DQ -37 .86 2.203 L 11. 00 C=120 PT 46 .73 (257 ) Q 60 .11 F=0 F 0.00 PE 0 .00 CM2 T 11 .00 0 .0269 PF 0 .30 259 258DQ -31 .05 2 .203 L 11. 00 C=120 PT 47.03 (258 ) Q 29.06 F=O 1 F 0.00 PE 0.00 CM2 T 11. 00 0.0070 PF 0.08 239 259 2.2 03 L 47.00 C=120 PT 47.11 (2 59 ) Q 29.06 F=T/T,E F 28.00 PE 0 .00 BL T 75.00 0.0070 PF 0.53 219 239 2.203 L 1.00 C=120 PT 47.64 (239 ) Q 29.06 F=T F 11.60 PE 0.43 RN T 12.60 0.0070 PF 0.09 218 219 4.310 L 11. 00 C=120 PT 48.16 (219) Q 29.06 F=0 F 0.00 PE 0.00 CMl T 11. 00 0.0003 PF 0.00 217 218DQ 31.05 4.310 L 11. 00 C=120 PT 48.16 (218) Q 60.11 F=0 F 0.00 PE 0 .00 CM1 T 11. 00 0.0010 PF 0.01 216 217DQ 37.86 4.310 L 11.00 C=120 PT 48.17 ( 217) Q 97.97 F=0 F 0.00 PE 0.00 CMl T 11.00 0.0025 PF 0.03 215 216DQ 51.34 4.310 L • 11. 00 C=120 PT 48:20 (216) Q 149.30 F=O F 0 .00 PE 0.00 CM1 T 11. 00 0 .0055 PF 0.06 214 215DQ 73.44 4.310 L 37.00 C=120 PT 48.26 (215) Q 222.74 F=2E F 18.96 PE 0.00 CMl T 55.96 0.0115 PF 0.64 213 214DQ 207.06 4.310 L 11. 00 C=120 PT 48.90 (214) Q 429.80 F=0 F 0.00 PE 0.00 CM1 T 11. 00 0.0389 PF 0.43 212 213DQ 209.94 4.310 L 11.00 C=l20 PT 49.33 (213) Q 639.74 F=0 F 0.00 PE 0.00 CMl T 11.00 0.0813 PF 0.89 SUBMITTAL SERIAL NO :2932HY7 01-17-2 013 PAGE 5 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 211 212DQ 155.27 4.310 L · 11. 00 C=120 PT 50 .22 (212 ) Q 795.01 F=0 F 0 .00 PE 0 .00 CMl T 11.00 0 .1215 PF 1.34 210 211DQ 64.57 4.310 L 11. 00 C=120 PT 51.56 (211 ) Q 859.57 F=0 F 0 .00 PE 0.00 CMl T 11.00 0 .1403 PF 1. 54 209 210DQ 44.99 4.310 L '11. 00 C=120 PT 53.10 (210) Q 904.56 F=0 F 0.00 PE 0 .00 CMl T 11. 00 0 .1542 PF 1. 70 208 209DQ 44.14 4.310 L 11. 00 C=120 PT 54.80 (209 ) Q 948.70 F=0 F 0 .00 PE 0 .00 CMl T 11. 00 0 .1684 PF 1.85 207 208DQ 62.08 6.357 L 11. 00 C=120 PT 56.65 (208) Q 1 010 .78 F=0 F . 0 .00 PE 0 .00 CMl T 11.00 0.0285 PF 0 .31 206 207DQ 41. 25 6.357 L 11. 00 C=120 PT 56.96 (207) Q 1052.03 F=0 F 0 .00 PE 0.00 CMl T 11. 00 0.0307 PF 0 .34 205 206DQ 28.07 6.357 L 11. 00 C=120 PT 57.30 (206) Q 1080.10 F=0 F 0 .00 PE 0.00 CMl T 11.00 0 .0323 PF 0.36 204 205DQ 23.05 6.357 L 11.00 C=120 PT 57.66 (205 ) Q 1103.15 F=0 F 0.00 PE 0.00 CMl T 11. 00 0 .0335 PF 0.37 203 204DQ 26.64 6.357 L 11.00 C=120 PT 58.03 (204 ) Q 1129.79 F=0 F 0 .00 PE 0.00 CMl T . 11. 00 0 .0351 PF 0.39 9 203DQ 26.02 6.357 L 2.50 C=120 PT 58.42 (203) Q 1155.81 F'=0 F 0.00 PE 0.00 CMl T 2 .50 0.0366 PF 0.09 PT 58.51 9) ------------------ 316 315 2.203 L 8.00 C=120 PT 32.60 (315) Q 50.65 F=0 F 0.00 PE 0.00 BL T 8.00 0.0196 PF 0.16 317 316DQ 79.00 2.203 L 8.00 C=120 PT 32.76 (316) Q 129.64 F=0 F 0.00 PE 0.00 BL T 8.00 0.1114 PF 0.89 SUBMITTAL -SERIAL NO :2932HY7 01-17-2013 PAGE 6 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI ' 254 317DQ 80 .11 2.203 L 11.00 C=120 PT 33.65 (317 ) Q 2 09 .75 F=0/T,E F 16.40 PE 0 .00 BL T 27 .40 0.2712 PF 7.43 PT 41. 08 (254) ------------------ 314 315 2.203 L 8 .00 C=120 PT 32.60 (315) Q 28.15 F=0 F 0.00 PE 0 .00 BL T 8.00 0 .0066 PF 0.05 313 314DQ 78.87 2.203 L 8 .00 C=120 PT 32.65 (314) Q 107.02 F=0 F 0 .00 PE 0 .00 BL T 8.00 0.0781 PF 0.62 312 313DQ 79.65 2.203 L 8.00 C=120 PT 33.27 (313) Q i86.67 F=0 F 0 .00 PE 0.00 BL T 8.00 0 .2186 PF 1. 75 234 312DQ 81. 80 2.203 L 12.00 C=120 · PT 35.02 (3 12 ) Q 268.47 F=T F 11.60 PE 0.00 BL T 23.60 0 .4282 PF 10.11 PT 45.13 (234) ------------------ 308 309 2.203 L 8.00 C=120 PT 32.71 (309) Q 30.01 F=0 F 0.00 PE 0.00 BL T 8.00 0.0074 PF 0 .06 307 308DQ 79.01 2.203 L 8.00 C=120 PT 32.77 (308) Q 109.02 F=0 F 0.00 PE 0.00 BL T 8.00 0.0808 PF 0.65 306 307DQ 79.82 2.203 L 8.00 C=120 PT 33.42 ( 307) Q 188.84 F=0 F 0.00 PE 0.00 BL T 8.00 0.2233 PF 1. 79 233 306DQ 82.01 2.203 L 12.00 C=120 PT 35.21 (306) Q 270.85 F=T F 11.60 PE 0 .00 BL T 23.60 0.4352 PF 10.27 PT 45.48 (233) ------------------ 303 302 2.203 L 8.00 C=120 PT 41.63 ( 302) Q 74.31 F=0 F 0.00 PE • 0 .00 BL T 8.00 0.0398 PF 0.32 304 303 2.203 L 8.00 C=120 PT 41.95 (303) Q 74.31 F=0 F 0.00 PE 0.00 BL T 8.00 0.0398 PF 0.32 SUBMITTAL SERIAL NO:2932HY7 01-17-2013 PAGE 7 CARLSBAD TECH SYS #2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Le ng th Loss Summar y From To GPM IN De vices Ft PS I /Ft PSI 305 304 2.2 0 3 L 8 .00 C=12 0 PT 42.27 (304 ) Q 74.31 F=0 F 0.00 PE 0.00 BL T 8.00 0.0398 PF 0.32 252 3 05 2.203 L 11. 00 C=12 0 PT 42.59 (305 ) Q 74.31 F=0/T,E F 16.40 PE 0 .00 BL T 27 .40 0 .03 98 PF 1. 09 PT 43.68 (252 ) ------------------ 3 01 302 2.203 L 8 .00 C=12 0 PT 41.63 (3 02 ) Q 15 .17 F=0 F 0 .00 PE 0 .00 BL T 8 .00 0 .0021 PF 0 .02 300 301DQ 89 .50 2.203 L 8 .00 C=120 PT 41.65 (301) Q 104.66 F=0 F 0 .00 PE 0.00 BL T 8 .00 0 .0750 PF 0 .60 232 300DQ 90.16 2.2 03 L 12.00 C=120 PT 4 2 .25 (300) Q 194.83 F=T F 11.60 PE 0.00 BL T 23.60 0.2366 PF 5.58 PT 47.83 (232) ------------------ 274 234 2.203 ·L 55.00 C=120 PT 45.14 (234) Q 61.41 F=T/T,E F 28.00 PE 0.00 BL T 83 .00 0.0280 PF 2.32 273 274 2.203 L 11.00 C=120 PT 47.46 (274) Q 61.41 F=0 F 0.00 PE 0.00 CM3 T 11. 00 0.0280 PF 0.31 PT 47 .77 (273) ------------------ 273 233 2.203 L 55.00 C=120 PT 45.48 (233) Q 60.92 F=T/T,E F 28 .00 PE 0 .00 BL T 83.00 0.0275 PF 2 .28 272 273DQ 61.41 2.203 L 11. 00 C=120 PT. 47.76 (273) Q 122.33 F=0 F 0.00 PE 0.00 CM3 T 11.00 0.1000 PF 1.10 PT 48.86 (272) ------------------ 272 232 2.203 L 55.00 C=120 PT 47.83 (232) Q 39.56 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0.0124 PF 1.03 271 272DQ 122.33 2.203 L 11. 00 C=120 PT 48.86 (272) Q 161.88 F=0 F 0.00 PE 0.00 CM3 T 11. 00 0.1680 PF 1.85 SUBMITTAL SERIAL NO:2932HY7 01-17-2013 PAGE 8 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 231 271DQ -155 .73 2.203 L 55 .00 C=120 PT 50 .71 (271) Q 6 .16 F=T/T,E F 2 8 ;00 PE 0 .00 BL T 8 3.00 0 .0004 PF 0 .03 PT 5 0 .74 (231) ------------------ 270 271 2.203 L 11. 00 C=120 PT 5 0 .71 ( 271 ) Q 155 .73 F=0 F 0 .00 PE 0 .00 CM3 T 11. 00 0 .1563 PF 1 . 72 • 230 270DQ -148.40 2 .203 L 55 .00 C=120 PT 52 .43 (270 ) Q 7 .33 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0 .0005 PF 0 .04 PT 52.47 (230) ------------------269 270 2.203 L 11. 00 C=120 PT 52.43 (270) Q 148 .40 F=0 F 0 .00 PE 0 .00 CM3 T 11. 00 0 .1430 PF 1.57 229 269DQ -133.19 2.203 L 55.00 C=120 PT 54.00 (269) Q 15.21 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0.0021 PF 0 .17 PT 54.17 (229) ------------------ 268 269 2.203 L 11.00 C=120 PT 54.00 (269) Q 133.19 F=0 F 0 .00 PE 0.00 CM3 T 11. 00 0.1171 PF 1.29 228 268DQ -104.38 2.203 L 55.00 C=120 PT 55.29 (268 ) Q 2 8 .82 F=T/T ,E F ·28. 00 PE 0 .00 BL T 83.oo · 0 .0069 PF 0 .57 PT 55.86 (228) ------------------ 267 268 2 .. 203 L 11. 00 C=120 PT 55.29 (268) Q 1 04.38 F=0 F 0 .00 PE 0.00 CM3 T 11.00 0.0746 PF 0 .82 227 267DQ -85.69 2.203 L 55.00 C=120 PT 56.11 (267) Q 18 .69 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0 .0031 PF 0.26 PT 56.37 (227) • ----------------- 266 267 2.203 L 11.00 C=120 PT 56.11 (267) Q 85.69 F=0 F 0.00 PE 0.00 CM3 T 11.00 0.0518 PF 0.57 226 266DQ -73.78 2.203 L 55.00 C=120 PT 56.68 ( 266) Q 11. 91 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0.0013 PF 0.11 PT 56.79 (226) SUBMITTAL SERIAL NO:2932HY7 , 01-17-2013 PAGE 9 CARLSBAD .TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 '- Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI ------------------ 265 266 2.2 0 3 L 11.00 C=12 0 PT 56.68 (266 ) Q 73.78 F=0 F 0 .00 PE 0 .00 CM3 T 11. 00 0 .0393 PF 0 .43 225 265DQ -65 .26 2.203 L 55.00 C=120 PT 57.11 (265 ) Q 8.53 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0.0007 PF 0.06 PT 57.17 (225 ) ------------------264 265 2.203 L 11 .00 C=120 PT 57.11 (265) Q 65.26 F=0 F 0.00 PE 0.00 CM3 T 11. 00 0 .0313 PF 0.34 224 264DQ -56.18 2.203 L 55.00 C=120 PT 57.45 (264) Q 9.08 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0.0008 PF 0 .07 PT 57.52 (224) ------------------ 263 264 2.203 L 11.00 C=120 PT 57 .46 . (264) Q . 56 .18 F=0 F Q. QQ r PE 0.00 CM3 T 11.00 0.0237 PF 0.26 223 263DQ -40.03 2.203 L 55.00 C=120 PT 57.72 (263) Q 16.15 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0.0024 PF 0.20 PT 57.92 (223) ------------------ 262 263 2.203 L 9.50 C=120 PT 57.72 (263) Q 40.03 F=0 F 0.00 PE 0.00 CM3 T 9.50 0.0127 PF 0.12 222 262DQ -25.28 2.203 L 55.00 C=120 PT 57.84 (262) Q 14.75 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0.0020 PF 0.17 PT 58.01 (222) ------------------ 261 262 2.203 L 9.50 C=120 PT 57.84 (262) Q 25.28 F=0 F 0.00 PE 0.00 CM3 T 9 .50 . 0.0054 PF 0.05 221 261DQ -12.37 2.203 L 55.00 C=120 PT 57.89 (261) Q 12.91 F=T/T,E F 28.00 PE 0.00 BL T 83.00 0.0016 PF 0.13 PT 58.02 (221) ------------------260 261 2.203 L 9.50 C=120 PT 57.89 (261) Q 12.37 F=0 F 0.00 PE 0.00 .CM3 T 9.50 0.0014 PF 0.01 SUBMITTAL SERIAL NO:2932HY7 01-17-2013 PAGE 10 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 220 260 2.203 L 55.00 C=120 • PT 57.90 (260 ) Q 12.37 F=T/T,E F 28.00 PE 0.00 BL T 83 .00 0 .0014 PF 0 .12 PT 58.02 (220) ------------------238 258 2.203 L 47.00 C=l:20 PT 47.03 (258 ) Q 31. 05 F=T/T,E F 28.00 PE 0 .00 BL T 75.00 0.0079 PF 0.59 218 238 2.203 L 1.00 C=12 0 PT 47.62 ( 238 ) Q 31. 05 F=T F 11.60 PE 0 .43 RN T 12.60 0.0079 PF 0.10 PT 48.15 (218) ---------~-------- 237 257 2.203 L 47.00 C=120 PT 46.74 (257) Q 37.86 F=T/T,E F 28.00 PE 0 .00 BL T 75.00 0.0114 PF 0 .86 217 237 2.203 L 1.00 C=120 'PT 47.60 (23 7) Q 37.86 F=T F 11. 60 PE 0.43 RN .T 12.60 0 .0114 PF 0.14 PT 48.17 (217) ------------------ 236 256 2.203 L 47.00 C=120 PT 46.01 (256) Q 51.34 F::::T/T,E F 28.00 PE 0.00 BL T 75.00 0 .0201 PF 1.51 216 236 2.203 L 1.00 C=120 PT 47.52 (236) Q 51.34 F=T F 11. 60 PE 0.43 RN T 12.60 0.0201 PF 0.25 PT 48.20 (216) ------------------ 235 255 2.203 L 47.00 C=120 PT 44.42 ( 255) Q 73.44 F=T/T,E F 28.00 PE 0.00 I BL T 75.00 0.0389 PF 2.92 215 235 2.203 L 1.00 C=120 PT 47.34 (235) Q 73.44 F=T F 11. 60 PE · 0.43 RN T 12.60 0.0389 PF 0.49 PT 48.26 (215) ------------------ 252 253 2.203 L 11.00 C=120 PT 41.07 (253) Q 195.27 F=0 F 0.00 PE 0.00 CM2 T 11. 00 0.2376 PF 2.61 251 252DQ 74.31 2.203 L 11. 00 C=120 PT 43.68 (252) Q 269.58 F=0 F 0.00 PE 0.00 CM2 T 11.00 0.4315 PF 4.75 SUBMITTAL SERIAL NO:2932HY7 01-.1 7 -2 013 PAGE 11 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 231 251DQ -211.17 2 .2 03 L 63 .00 C=120 PT 48.43 (251) Q 58.41 F=T/T,E F 28.00 PE 0 .00 BL T 91. 00 0 .0255 PF 2.32 211 231DQ 6 .16 2.203 L 1.00 C=120 PT 5 0 .75 (231) Q 64.57 F=T F 11.60 PE 0 .43 RN T 12.60 0 .0307 PF 0.39 PT 51.57 (211) ------------------ 250 251 2.203 L 11. 00 C=120 PT 48.43 (251 ) Q 211.17 F=0 F 0 .00 PE 0.00 CM2 T 11. 00 0 .2746 PF 3.02 230 250DQ -173.51 2 .203 L 63.00 • C=l20 PT 51.45 (250) Q 37.66 F=T/T,E F 28.00 PE 0.00 BL T 91. 00 0.0113 PF 1.03 210 230DQ 7.33 2.203 L 1.00 C=120 PT 52.48 ( 230) Q 44.99 F=T F 11. 60 PE 0.43 RN T 12.60 0.0157 PF 0.20 PT 53.11 (210) ---------~-------- 249 250 2.203 L 11.00 C=120 PT 51.45 (250) Q 173.51 F=0 F 0.00 PE 0.00 CM2 T 11.00 0 .1909 PF 2.10 229 249DQ -144 .57 2.203 L 63.00 C=120 PT 53.55 (249) Q 28.93 F=T/T,E F 28.00 PE 0.00 BL T 91. 00 0 .0069 PF 0.63 209 229DQ 15.21 2.203 L 1.00 C=120 PT 54.18 (229) Q 44.14 F=T F 11.60 PE 0.43 RN T 12.60 0.0152 PF 0.19 PT 54.80 (209) ------------------ 248 249 2.203 L 11.00 C=120 PT 53.55 (249) Q 144.57 F=0 F 0.00 PE 0.00 CM2 T 11.00 0.1363 PF 1.50 228 248DQ -111.31 2.203 L 63.00 C=120 PT 55.05 (248) Q 33.26 F=T/T,E F 28.00 PE 0.00 BL T 91. 00 0.0090 PF 0.82 208 228DQ 28.82 2.203 L 1.00 C=120 PT ,55.87 (228) Q 62.08 F=T F 11. 60 PE 0.43 RN T 12.60 0.0285 PF 0.36 PT 56.66 (208) SUBMITTAL SERIAL NO:2932HY7 01-17 -2013 PAGE 12 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI ------------------247 248 2.2 0 3 L 11.00 C=120 PT 55.05 ( 248 ) Q 111. 31 F=0 F 0.00 PE 0 .00 CM2 T 11. 00 0 .0840 PF 0 .92 227 247DQ -88 .75 2.203 L 63.00 C=120 PT 55.97 (247 ) Q 22.56 F=T/T,E F 28.00 PE 0 .00 BL T 91. 00 0 .0044 PF 0 .40 207 227DQ 18.69 2.203 L 1.00 C=120 PT 56.37 ( 227 ) Q 41.25 F=T F 11.60 PE 0 .43 RN T 12.60 0.0134 PF 0.17 PT 56.97 (207) ------------------246 247 2.203 L 11. 00 C=120 PT 55.97 (247)· Q 88.75 F=0 F 0 .00 PE 0.00 CM2 T 11.00 0.0552 PF 0 .61 226 246DQ -72.59 2.203 L 63.00 C=120 PT 56.58 (246) Q 16.16 F=T/T,E F 28.00 PE 0.00 BL T 91. 00 0.0024 PF 0.22 206 226DQ 11.91 2.203 L 1.00 C=120 PT 56.80 (226) Q 28.07 F=T F 11.60 PE 0.43 RN T 12.60 0.0066 PF 0.08 PT 57.31 (206) ------------------ 245 246 2.203 L 11.00 C=120 PT 56.58 (246) Q 72.59 F=0 F 0.00 PE 0.00 CM2 T 11. 00 0.0381 PF 0.42 225 245DQ -58.06 2.203 L 63.00 C=120 PT 57.00 (245) Q 14.52 F=T/T,E F 28.00 PE 0.00 .BL T 91. 00 ,0 . 0019 PF 0.17 205 225DQ 8 .53 2.203 L 1.00 C=120 PT 57.17 (225) Q 23.05 F=T F 11.60 PE 0.43 RN T 12.60 0.0046 PF 0.06 PT 57.66 (205) ------------------ 244 2.45 2.203 L 11. 00 C=120 PT 57.00 (245) Q 58.06 F=0 F 0.00 PE 0 .00 CM2 T 11.00 0.0252 PF 0.28 224 244DQ -40.50 2.203 L 63.00 C=120 PT 57.28 (244) Q 17.56 F=T/T,E F 28.00 PE 0.00 BL T .91. 00 0.0028 PF 0.25 SUBMITTAL ·SERIAL NO:2932HY7 \01-17 -2013 PAGE 13 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 204 224DQ 9.08 2.203 L 1.00 C=12 0 PT 57 .53 (224) Q 26.64 F=T F 11.60 PE 0.43 RN .T 12.60 0 .0060 PF 0 .08 PT 58.04 ( 204 ) ------------------ 243 244 2.203 L 35.00 C=120 PT 57.27 (244 ) Q 40.50 F=2E F 9.60 PE 0 .00 CM2 .T 44.60 0 .0129 PF . 0 .58 223 243DQ -30 .63 2.203 L 38.00 C=120 PT 57.85 (243 ) Q 9.87 F=T/T,E F 28.00 PE 0.00 BL T 66.00 0.0009 PF 0.06 203 223DQ 16.15 2.203 L 1.00 C=120 PT 57.91 (223) Q 26.02 F=T F 11.60 PE 0.43 RN T 12.60 0 .0057 PF 0 .07 PT 58.41 (203) ------------------ 242 243 2.203 L 9.50 C=120 PT 57.85 (243) Q 30.63 F=0 F 0.00 PE 0.00 CM2 T 9.50 0.0077 PF 0.07 222 242DQ -19.40 2.203 L 38.00 C=120 PT 57.92 (242) Q 11.23 F=T/T, E . F 28.00 PE 0.00 BL T 66.00 0.0012 PF 0 .08 202 222DQ 14.75 2.203 L 1.00 C=120 PT 58.00 (222) Q 25.98 F=T F 11.60 PE 0.43 RN T 12.60 0.0057 PF 0.07 PT 58.50 (202) ------------------241 242 2.203 L 9.50 C=120 PT 57.92 (242) Q 19.40 F=0 F 0.00 PE 0.00 CM2 T 9.50 0.0033 PF 0.03 221 241DQ -9.51 2.203 L 38.00 C=120 PT 57.95 (241) Q 9.90 F=T/T,E F 28.00 PE 0.00 BL T 66.00 0.0010 PF 0.07 201 221DQ 12.91 2.203 L 1.00 C=120 PT 58.02 (221) Q 22.80 F=T F . 11.60 PE 0.43 RN T 12.60 0.0045 PF 0.06 PT 58.51 (201) ------------------ 240 241 2.203 L 9.50 C=120 PT 57.95 (241) Q 9.5l F=0 F 0.00 PE 0.00 CM2 T 9.50 0.0009 PF 0 .01- SUBMITTAL SERIAL NO :2932HY7 01 -17-2013 PAGE 14 CARLSBAD TECH SYS#2 15 HEADS AT 22 PSI ULTRA K-17 Location Flow Pipe Fittings Equiv Friction Pressure in · Size & Length Loss Summary From To GPM IN Devices Ft PSI /Ft PSI 220 240 2.203 L 38.00 C=120 PT 57 .96 (240 ) Q 9.51 F=T/T,E F 28.00 PE 0 .00 BL T 66.00 0 .0009 PF 0 .06 200 220DQ 12.37 2.203 L 1.00 C=120 PT 58.02 (22 0) Q 21.88 F=T F I 11.60 PE 0 .43 RN T 12.60 0.0041 PF 0 .05 201 200 6 .35 7 L 9.50 C=120 PT 58.50 (200 ) Q 21.88 F=0 F 0.00 PE 0.00 CMl .T 9.50 0 .0000 PF 0.00 202 201DQ 22.80 6.357 L 9.50 C=120 PT 58.50 (2 01 ) Q 44.68 F=0 F 0 .00 PE 0 .00 CMl T 9.50 0.0001 PF 0.00 9 202DQ 25 .98 6.357 L 7.00 , C=120 PT 58.50 (202) Q 70.66 F=0 F 0.00 PE 0.00 CMl T 7.00 0.0002 PF 0.00 PT 58.50 9) ------------------ 214 234 2.203 L 1 .00 C=120 PT 45.14 (234) Q 207.06 F=T F 11. 60 PE 0.43 RN T 12.60 0 .2648 PF 3.34 PT 4,8.91 (214) ------------------ 213 233 2.203 L 1.00 C=120 PT 45.48 (233) Q 209.94 F=T F 11.60 PE 0.43 RN T 12.60 0.2717 PF 3.42 PT 49.33 (213) ------------------ 212 232 2.203 L 1.00 C=120 PT 47.83 (232) Q 155.27 F=T F 11.60 PE 0.43 RN T 12.60 0 .1555 PF 1.96 PT 50.22 (212) ---------~-------- 3 9 6 .35 7 L 75.00 C=120 PT 58.51 ( 9) Q 1226.47 F=E,T F 44.00 PE 0.00 FM T 119.00 0.0408 PF 4.86 1 3 6 .. 357 L 22.00 C=120 PT 63.37 3) Q 1226.47 F=E F 12.57 PE 9.53 FR T 34.57 0.0408 PF 1.41 0 1 5.914 L 50.00 C=150 PT 74.31 1) Q 1226.47 F=T,4E/2GV,E F 163.31 PE 2.75 UN T 213.31 0.0384 PF 8.19 COMMENT: 2.75 PS.I LOSS FOR AMES 1000 DCV SHOWN AS ELEVATION PT 85.25 0) \\\ KLAUSBRUCKN ER \ 'l AND ASS OCIATES -' 4105 Sorrento Valley Blvd. San Diego, CA 92121 Tel: (858) 677-9878 Fax: (858) 677-9894 Carlsbad Technologies Inc. 5928 Farnsworth Court Carlsbad, CA High-Piled Combustible Storage Summary Table Rev 2.0 December 13, 2012 /tSt3 00 ts 1. Summary Table 1. 1 Combustible Storage TOPIC Construction Type Approximate Square Footage Occupancy Storage Commodity Automatic Sprinkler Protection Rev 2.0 CODE SECTION CBC Sections 302, 304,311 CFC Sections 2303.1, 2303.4, 2303.5, 2303.7.1 NFPA-13, 2010, Table A.5.6.3 CFC 2308.1, 2308.2, Table 2306.2 NFPA-13, 2010, Sections 3.9.3.7.1, 3.9.3.7.5, 3.9.3.7.7, 3.9.3.7.9, 3.9.3.8 NFPA-13, 2010, Sections 8.11.2, 8.11.6, 8.11.3.1, 8.11.3.4, 17.2.2, Tables 8.11.2.2.1, 17.2.2.1 Carlsbad Technologies Inc. -5928 Farnsworth Court, Carlsbad, CA CRITERIA/REQUIREMENTS Existing Building-No proposed changes. Entire First Floor Building: 49,415 ft2 High Piled Storage: 28,704 ft2 [S-1, Storage] Storage (non-high piled): 17,899 ft2 [S-1, Storage] Office Area: 2,812 ft2 [B, Business] Mezzanine Office Area: 3,191 ft2 rn, Business] Mixed Use Groups: B (Business) and S-l(Storage). No occupancy separation required between B and S-1. Class III -Non-combustible liquid in Plastic Containers (> 5 gallon capacity); Non-combustible powder in Cardboard Drums; Non- combustible powder in paper bags; Flattened cardboard boxes Class IV -Grease paper; Empty plastic bottles; Plastic cups (1-2 oz) free-flowing; Group A Plastics -Non-combustible powder in Plastic Drums Rack Storage Area Sprinkler Protection: Group A Plastic Commodities, Unexpanded, Cartoned • Maximum Storage Height: s 22 '-0" • Maximum Ceiling Height: < 29'-0" ■ Aisle Widths: ~ 8'-0" • Double-and Single-Row Racks • Open shelves, area> 50% open • Maximum spacing for storage with density> 0.25 = 100 ft2 ■ Maximum spactng between ceiling sprinklers for storage with density> 0.25 = 12'-0" Ceiling Sprinkler Option #1: • Maximum storage heights 25' -0" • Maximum ceiling heights 30' -0" ■ Control Mode Specific Application (CMSA) upright sprinklers, 16.8 k-factor • 15 sprinklers calculated at 22 psi ■ Minimum clearance 36" from deflector to top of storage • Maximum coverage area 100 ft2 per sprinkler ■ Maximum distance between sprinklers 10'-0" [for combustible obstructed construction] or 12'-0" [for unobstructed and noncombustible obstructed construction] ■ Minimum distance between sprinkler 8'-0" • Hose allowance 500 gpm Existing sprinkler system density of 0.33 gpmlfr, and remote area of 3,000 Jr does not meet the requirements for this option for this commodity, in this configuration, to this height. Available water supply and sprinkler system configuration may be able to supply systems as modified in options above, once sprinklers have been replaced. Sorinkler contractor to provide hydraulic calculations. \\.\. KLAU5BH UCKNl:.H )'l AND ASSOCIATES Page I