Loading...
HomeMy WebLinkAboutPRE 2024-0015; PHOENIX RENEWABLE SERVICES; Admin Decision LetterApril 24, 2024 Bruce W. Steingraber 24665 Rancho Santa Teresa Drive Ramona, CA 92065 City of Carlsbad APR 2 4 2024 Planning Division SUBJECT: PRE 2024-0015 (DEV2024-0031) -PHOENIX RENEWABLE SERVICES APN: 212-092-28-00 (cityof Carlsbad Thank you for submitting a preliminary review application for the addition of a 3,210-square-foot mezzanine to be used as office space and the addition of an exterior observation deck to an existing 9,987- square-foot warehouse and office building. The project site, an approximately 0.79-acre (34,590-square- foot) lot, is located at 1946 Kellogg Drive. Identified as Lot 3 in MS 95-05/PIP 95-08/PUD 95-02, the building was one of four buildings originally approved in 1996 for an office/manufacturing use. The property is located within Safety Zones 2 and 5 of the McClellan Palomar Airport Land Use Compatibility Plan. In response to your application, the Planning Division has prepared this comment letter. Please note that the purpose of a preliminary review is to provide you with direction and comments on the overall concept of your project. This preliminary review does not represent an in-depth analysis of your project. It is intended to give you feedback on critical issues based upon the information provided in your submittal. This review is based upon the plans. policies, and standards in effect as of the date ofthis review. Please be aware that at the time of a formal application submittal, new plans, policies, and standards may be in effect and additional issues of concern may be raised through a more specific and detailed review. Planning: 1. General Plan and zoning designations for the property are as follows: a. General Plan: Planned Industrial (Pl). b. Zoning: Planned Industrial (P-M). c. The property is located within Area 1 ofthe Carlsbad Airport Centre Specific Plan (SP 18l(H)). d. The property is located within Safety Zones 2 and 5 ofthe McClellan Palomar Airport Land Use Compatibility Plan (ALUCP). 2. The project requires the following permits: a. Building Permit Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0015 (DEV2024-0031) -PHOENIX RENEWABLE SERVICES April 24, 2024 Pa e2 b. Amendment to Planned Industrial Permit, PIP 95-08. A Planned Industrial Permit is no longer an applicable submittal type; Amendment to Minor Site Development Permit is current application type required. c. Amendment to Non-Residential Planned Development Permit PUD 95-02. Please submit a copy of any reciprocal agreements that exist with the adjacent properties. If amendments are needed to a reciprocal agreement, an amendment to PUD 95-02 may be required. 3. Plans: a. Show: Property lines, easements, existing and proposed structures, and dimensioned setbacks, based on Map No. 17721. b. Provide an existing site plan and floor plan. c. Add the proposed size in square feet of the observation deck to the scope of work. d. Update the site acreage on the cover sheet to only include the size of Lot 3 per Map No. 17721 (0. 79 acres). e. Provide a square footage table for the existing and proposed structures. f. Per the approval letter for PIP 95-08/PUD 95-02, the development of Lot 3 required 26 parking spaces. Please revise the project data section on the cover sheet. g. The plans state the existing building area as 10,209-square-feet. PIP 95-08/PUD 95-02 approved the development of a 9,987-square-foot building on the lot. Please confirm the existing square footage for the building and amend the plans accordingly. If additional square footage has been added, it should be accounted for in the existing and proposed parking calculations. h. Revise the plans to show only the parking spaces allotted for Lot 3 per PIP 95-08/PUD 95-02. Only the spaces located on Lot 3 and directly adjacent to the north and east sides of the existing building can be used. A total of 26 spaces were originally approved/provided. 4. McClellan Palomar Airport Land Use Plan. The project site is located within the McClellan-Palomar Airport Influence Area (AIA). New development within the AIA must be reviewed for consistency with the adopted land use compatibility plan for the airport. The ALUCP is available at the following address: https:ljwww.san.org/DesktopModules/Bring2mind/DMX/API/Entries/Download?Entryld=16147&C ommand=Core Download&language=en-US&Portalld=0& Tabld=807 Review of the project against the ALUCP revealed the following: Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0015 (DEV2024-0031) -PHOENIX RENEWABLE SERVICES April 24, 2024 Pa e 3 a. Exhibit 111-1 -Compatibility Policy Map: Noise. The project site is located within the 70-75 dB CNEL noise exposure range per Exhibit 111-1. Pursuant to the ALUCP Section 3.3.3(c) on page 3- 19, "compatibility of new nonresidential development with noise levels generated by the Airport is indicated in Table 111-1." Table 111-1 on pg. 3-23 identifies office type uses, as a conditionally compatible use within the 70-75 dB CNEL noise exposure range. Specifically, to be compatible, the building structure must be designed to attenuate exterior noise to the indoor CNEL of 50 CNEL. Please submit a noise study with the application demonstrating how the project complies with the ALUCP. The noise analysis shall describe the exterior noise environment and the acoustical design features required to achieve the interior noise standards. Evidence shall also be provided which indicates that the specified sound attenuation measures have been incorporated into the design of the project. b. Exhibit 111-2 -Compatibility Policy Map: Safety. The subject parcel is located within Safety Zones 2 (area in purple-Inner Approach/Departure Zone) and 5 (area in orange, Sideline Zone). Pursuant to Policy 3.4.11, project sites lying partially within multiple Safety Zones shall be considered as if it were multiple parcels divided at the compatibility zone boundary line. The existing building appears to be located entirely within Safety Zone S; therefore, the proposal to add a mezzanine and observation deck is required to comply with the requirements of Safety Zone 5. Mezzanine/Office Addition: Pursuant to Table 111-2 (Pgs. 3-45 through 3-52), office buildings are considered conditionally compatible within Safety Zone 5. Per Table 111-2, conditional uses shall either comply with the Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0015 (DEV2024-0031) -PHOENIX RENEWABLE SERVICES April 24, 2024 Pa e 4 Maximum Intensity and Lot Coverage Limits or the maximum FAR. Both sets of calculations will need to be shown on the plans. On page 3-43 of the ALCUP, FAR is calculated by people per acre multiplied by the occupancy load factor (or square footage per person) for each land use divided by 43,560. Further, it needs to be determined whether risk reduction objectives are incorporated into the project design as there are two different categories for the FAR and Maximum Intensity as follows. Zone 5 for office use: Maximum Intensity: 200 Maximum Intensity with Risk Reduction Measures: 400 Maximum Lot Coverage: 70% FAR: 0.99 (or 1.97 with risk reduction measures) Staff cannot verify that the project complies with limitations of Safety Zone 5 until the appropriate calculations have been completed. Please determine the occupancy load factor to complete the calculation. Please refer to page 3-43 of the ALUCP for details. In addition, please note the area of the parcel located within Zone 2 shall be excluded from the calculation. Please determine the area of the lot located within Zone 5. Exterior Observation Deck Addition: Please confirm the California Building Code (CBC) Group and occupancy for the proposed exterior deck addition. Please note, outdoor small assembly facilities with a capacity for 50 to 299 people (CBC, Assembly Group A-4) are prohibited uses in Safety Zone 5. Additional information is required to determine with this use can be allowed. c. Exhibit 111-3 -Compatibility Policy Map: Part 77 Airspace Protection. Pursuant to Exhibit 111-3, the project is located within the boundaries of the FAA notification area for the airport. The airport elevation is 331 feet above mean sea level (AMSL). Pursuant to Part 77 of the FAA regulations, the FAA shall be notified of any proposed construction or alteration having a height greater than an imaginary surface extending 100 feet outward and 1 foot upward (slope of 100:1) from the runway elevation. As the building height is not proposed to be altered, a Part 77 application will not be required to be filed with the FAA. d. Exhibit 111-4 -Compatibility Policy Map: Overflight. The project site_ is located within the Overflight Notification Area. However, pursuant to the ALUCP Policy 3.6. -Overflight Compatibility Policies for McClellan-Palomar Airport, Section 3.6.3(c), page 3-57, recordation of an overflight notification document is not required for nonresidential development. It is also not required when an avigation easement is required. e. Exhibit 111-5-Compatibility Policy Map: Airport Influence Area. The project site is located within Review Area #1 of the Airport Influence Area. Review Area #1 consists of locations where noise and/or safety concerns may necessitate limitations on the types of land use actions. Please see discussions above in subsection a) and b). f. Exhibit 111-6 -Compatibility Policy Map: Avigation Easement Area and Overflight Notification Areas. The project site is located within the Avigation Easement Area. Pursuant to ALUCP Policy Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0015 (DEV2024-0031) -PHOENIX RENEWABLE SERVICES April 24, 2024 Pa e 5 3.3.3, the dedication of an avigation easement in accordance with Policy 2.11.5 of Chapter 2 is a requirement for compatibility of any type of development within the 65 dB CNEL contour that is designated as a conditional use. As the building is existing, the agreement was required as part of the original development and will not be required for the proposed amendment. 5. Parking: a. Pursuant to Condition No. 20 of PIP 95-08/PUD 95-02, a total of 500 square feet was permitted for office use and 9,497 square feet was permitted for manufacturing use for Lot 3. Please provide the current square footage of office and warehouse space in the building to verify the existing uses comply with the parameters of Condition No. 20 and to assist staff with the parking calculation for the proposed tenant improvement. b. In total, Lot 3 required 26 parking spaces per PIP 95-08/PUD 95-02. The original approval did not permit joint use of parking between Lots 1-4. Condition No. 20 states, each lot must stand on its own for parking purposes. A breakdown of the approved parking for Lot 3 is provided in Table 1 below. Table 1: Permitted Onsite Parkin~ for Lot 3 Use Parking Requirement Approved SQ. FT. Required Spaces Office 1 parking space I 250 500 2 square feet Manufacturing 1 parking space I 400 9,497 24 square feet Total Required 26 Total Provided 26 c. The proposed addition of the mezzanine on the second floor would increase the office area gross square footage of the building by 3,210 square feet. To determine if the site contains adequate parking for the existing and proposed uses, please provide the following information on the site plan: i. A parking analysis table breaking down the required parking for the existing and proposed uses on the site in accordance with the parking standards outlined in CMC Section 21.44.020. ii. Pursuant to CMC Section 21.44.020, a total of 13 additional parking spaces (1 space/250 square feet) would be required for the proposed mezzanine addition. Based on a review of the existing site plan and the prior project approval, it does not appear there is room to add 13 additional parking spaces on Lot 3. 6. Building Coverage: a. Pursuant to CMC 21.04.061, building coverage includes the total ground area of a site occupied by any building or structure as measured from the outside of its surrounding external walls or Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0015 (DEV2024-0031} -PHOENIX RENEWABLE SERVICES April 24, 2024 Pa e 6 supporting members. Building coverage includes exterior structures such as stairs, arcades, bridges, permanent structural elements protruding from buildings such as overhanging balconies, oriel windows, stories which overhang a ground level story, garages, and covered carports. Excluded from building coverage are roof eaves extending less than thirty inches from the face of any building, awnings, open parking areas, structures under thirty inches in height and masonry walls not greater than 6' in height such as wing-walls, planter walls or grade- separation retaining walls. b. The maximum lot coverage allowed per the ALUCP is 70%. Please provide a line-item lot coverage calculation on the site plan, which includes the proposed observation deck. Please note, only the area of the parcel located in Zone 2 can be used to assess compliance. 7. Setbacks: Add a setback table to the site plan. Per the Carlsbad Airport Centre Specific Plan (SP 181(H)), building setbacks are as follows: a. Interior Setback: 10 feet b. Rear Setback: 25 feet Please note, the posts of the deck shall comply with the 10-foot interior/side yard setback and a maximum overhang of two feet for the deck can be permitted in the setback area. 8. Employee Eating Area: Pursuant to CMC Section 21.30.070, a minimum of 300 square feet of outdoor eating facilities shall be provided for each 5,000 square feet of building area. a. Based on PIP 95-08, a total of 2,000 square feet of outdoor eating space was provided for Lots 1-4. Please provide an indoor/outdoor eating area exhibit on the site plans showing how the project, with the addition of the mezzanine complies with the requirement. Additional information is needed to determine if the employee eating area is shared between the four existing buildings or the requirements have been independently satisfied for each individual lot/building. 9. Climate Action Plan (CAP): New requirements related to the city's goals to reduce greenhouse gas (GHG) emissions will likely impact development requirements of this project. A formal application submittal will need to include a completed Climate Action Plan Checklist (Form P-30) to determine what requirements will apply to the project. New GHG reduction requirements are related to energy efficiency, photovoltaic, electric vehicle charging, water heating and traffic demand management requirements, as set forth in the California Green Building Standards Code and in Carlsbad Municipal Code Chapters 18.21, 18.30 and 18.51 which is available on the city's website at the following address: http:llwww.gcode.us/codes/carlsbad/view.php?topic=18&frames=on To the extent that new GHG reduction requirements are in effect at the time of application for grading or building permits, the project will be required to comply with the effective requirements even if different than what is proposed in the project's planning approvals. GHG reduction requirements may impact, but are not limited to, site design and local building code requirements. If incorporating new Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0015 (DEV2024-0031) -PHOENIX RENEWABLE SERVICES April 24, 2024 Pa e 7 GHG reduction requirements results in substantial modifications to the project after planning approvals are obtained, then prior to issuance of building permits, the applicant may be required to submit and receive approval of a Consistency Determination or an Amendment application for the project through the Planning Division. All necessary application forms, submittal requirements, and fee information are available at the Planning counter located in the Faraday Building at 1635 Faraday Avenue or online at https:ljwww.carlsbadca.gov/departments/community-development/planning. You may also access the General Plan Land Use Element and the Zoning Ordinance online at the website address shown. Please review all information carefully before submitting. Land Development Engineering: Land Development Engineering Division staff has completed a preliminary review of the above-referenced project. Prior to formal application for the project permit submittal, the following items must be adequately resolved/addressed, unless otherwise noted: 1. Complete a Stormwater Standards Questionnaire Form E-34. This questionnaire will guide you and the city in determining what type of reports and storm water mitigation must be completed to satisfy state and City storm water quality requirements. The questionnaire is located on the City of Carlsbad website. 2. Expansion for a new entry and footing for the observatory deck will make this project subject to the City of Carlsbad trash capture requirements based on this project's general land use Pl. Incorporate trash capture measures on the project plans and prepare a Preliminary Trash Capture Storm Water Quality Management Plan. Form E-35A is found on the city's website and is submitted directly to Land Development Engineering 3. Provide ADT and peak hour trips per generation rates from SAN DAG Brief Guide of Vehicular Traffic Generation Rates for the San Diego Region on the site plan/tentative map. 4. Correctly plot the property lines, including all bearings, deltas, and distances, based on Map No. 17721. 5. Provide a Preliminary Title Report (current within the last six (6) months). 6. Annotate and delineate all existing easements and encumbrances listed in the Preliminary Title Report on the site plan. 7. Identify all existing surface improvements screened back (curb, gutter, sidewalk, paving, manholes, inlets, street lights, adjacent driveways, vaults, transformers, etc.) at the project site, project frontage and within 20 feet of the boundary. 8. Delineate all existing and proposed retaining walls that will be utilized on the project site and show top of wall and bottom of wall elevations, including at the highest and lowest points. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0015 (DEV2024-0031) -PHOENIX RENEWABLE SERVICES April 24, 2024 Pa e 8 9. Indicate the earthwork quantities (cut, fill, import, export, remedial) for the deck structural footing. Provide the information in cubic yards. 10. Indicate the method of draining the deck. 11. Provide typical street cross sections for existing Kellog Avenue. Provide existing right-of-way width and existing improvements. Existing record numbers: DWG 344-7B, DWG 344-7A are available on the city's public records access. 12. Show all existing utilities and callout size for: water, sewer, storm drain, underground dry utilities in Kellogg Avenue and on-site. 13. Plot existing water services, meters, backflows, and sewer laterals for the project in compliance with 2022 Carlsbad Engineering Design Standards requirements. 14. Provide multiple cross-sections of the proposed deck to demonstrate differences in grade from adjacent properties. Plot existing grades on-site, fences and location of structures on-site and on adjacent properties. 15. Address the comments on the attached redlined plan. 16. Please be advised that a more in-depth review of the proposed development will occur with the discretionary permit application when a more complete design of the project is provided. Building Division: 1. CASp review is recommended before entitlement. Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600 PRE 2024-0015 (DEV2024-0031) -PHOENIX RENEWABLE SERVICES April 24, 2024 Pa e 9 Fire Department: 1. Fire sprinklers shall be extended to the mezzanine and observation deck. Any storage within the mezzanine over 12 feet in height shall require a High Piled Storage review from Fire. If you would like to schedule a meeting to discuss this letter with the commenting departments, please contact Megan McElfish at the number below. You may also contact each department individually as follows: • Planning Division: Megan McElfish, Assistant Planner, at (442) 339-5153 • Land Development Engineering: Linda Ontiveros, Project Engineer, at (442) 339-2773 • Fire Department: Randy Metz, Fire Marshall, at (442) 339-2661 • Building Division: Mike Strong, Assistant Director of Community Development, at (442) 339-2661 Sincerely, ERIC LARDY, AICP City Planner EL:O:MM:d Attachments: LDE Redlines c: Hassan Yarpezeshkan, 2810 Inverness Drive, La Jolla, CA 92037 Linda Ontiveros, Project Engineer Laserfiche/File Copy Data Entry Community Development Department Planning Division I 1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2600