HomeMy WebLinkAbout2353 JEFFERSON ST; ; CBR2022-1071; PermitBuilding Permit Finaled
Residential Permit
Print Date: 02/23/2024
Job Address: 2353 JEFFERSON ST,
Permit Type: BLDG-Residential
Parcel#: 1551802800
Valuation: $59,819.51
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Occupant Load:
Code Edition:
Sprinkled:
Project Title:
CARLSBAD, CA 92008-1405
Work Class:
Track#:
Lot#:
Project#:
Plan#:
Construction Type:
Orig. Plan Check#:
Plan Check#:
Addition
Description: HIRSCHKOFF: 345 SF ADDITION (TO ADD 1 BED, 1 FULL BATH)// 67 SF BALCONY
Property Owner:
CO-OWNERS HIRSCHKOFF JOEL AND
HIRSCHKOFF HEATHER
1483 CORAL WAY
SAN MARCOS, CA 92078-7988
FEE
BUILDING PLAN CHECK
BUILDING PLAN CHECK
BUILDING PLAN REVIEW-MINOR PROJECTS (LDE)
BUILDING PLAN REVIEW-MINOR PROJECTS (PLN )
DECKS/BALCONY-NEW/REPLACE
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
SB1473 -GREEN BUILDING STATE STANDARDS FEE
SFD & DUPLEXES
STRONG MOTION -RESIDENTIAL (SMIP)
SWPPP INSPECTION FEE TIER 1 -Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1 -Medium
Total Fees: $4,091.33 Total Payments To Date: $4,091.33
(City of
Carlsbad
Permit No: CBR2022-1071
Status: Closed -Finaled
Applied: 03/30/2022
Issued: 11/04/2022
Finaled Close Out: 02/23/2024
Final Inspection: 01/23/2024
INSPECTOR: Renfro, Chris
Balance Due:
de Roggenbuke, Dirk
AMOUNT
$755.30
$536.25
$194.00
$98.00
$825.00
$175.00
$3.00
$1,162.00
$7.78
$271.00
$64.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
{'cicyof
Carlsbad
Job Address 2353 JEFFERSON STREET
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan CheckQ3/Z;20dd -} (> + (
Est. Value $$:I, Rl'f, 5"0
PC Deposit
,5/3obcJ. ' Date
Unit: APN: 155-180-20-00 -----·
CT/ProJ·ect#: Lot#: Vear Built: 2017 --------------------------------
BRIEF DESCRIPTION OF WORK: ADDITION TO EXISTING SINGLE-FAMILY RESIDENCE. ADDITION TO INCLUDE 1 BEDROOM + 1 FULL BATHROOM
G] New SF : Living SF, 345 Deck SF,~ 7 'Df"' Patio SF, ____ Garage SF __ _
Is this to create an Accessory Dwelling Unit ? O Y (:) N New Fireplace? O YO N , if yes how many? ___ _
D Remodel: _____ SF of affected area Is the area a conversion or change of use? O YO N
□ Pool/Spa: ____ SF Additional Gas or Electrical Features? -------------
□Solar: ___ KW, ___ Modules, Mounted:0Roof0Ground, Tilt: ()YON, RMA: OY ON,
Battery:OYO N, Pan el Upgrade:OYON
Other:
PRIMARY APPLICANT
Name: JASON MOLGREN (3-POINTS DESIGN+BUILD)
Address: 1506 w 10TH ST.
City: SAN PEDRO
Phone: 281.684.4871
Email: jason@3pointsdb.com
DESIGN PROFESSIONAL
State:_c_A __ .Zip: 90732
Name: JASON MOLGREN (3-POINTS DESIGN+BUILD)
Address: 1506 w 10TH ST.
City: SAN PEDRO
Phone: 201 .684.4871
Email: jason@3pointsdb.com
State:,_c_A __ ,Zip: 90732
PROPERTY OWNER
Name: JOEL HIRSCHKOFF
Address: 2353 JEFFERSON ST.
City: CARLSBAD
Phone: 858.378.5047
Email: hirsch@gat.com
CONTRACTOR OF RECORD
State:_c_A __ Zip: 92008
Business Name: ________________ _
Address: __________________ _
City: _______ State:, ___ Zip: ______ _
Phone: __________________ _
Email: ___________________ _
Architect State License: ___________ _ CSLB license #: _______ Class: _______ _
carlsbad Business License # (Required): _______ _
APPL/ CANT CERT/ Fl CA Tf ON: I certify that I hove read the application and state that the above information is correct and that the information of the plans is accurate. I
agree to comply with o/1 City ordinonces ond State lows relating to building construction.
NAME (PRINT): JASON MOLGREN ~..:::> l ~-=-·-SIGN: ________ DATE: 03/27/2022
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8SS8 Email: 8uild1ng@carlsbadca.gov
REV. 10/21
THIS PAGE REQUIRED AT PERMIT ISSUANCE PLAN CHECK NUMBER: ______ _
A BUILDING PERMIT CAN BE ISSUED TO EITHER A STATE LICENSED CONTRACTOR OR A PROPERTY OWNER. IF THE PERSON SIGNING
THIS FORM IS AN AGENT FOR EITHER ENTITY AN AUTHORIZATION FORM OR LETTER IS REQUIRED PRIOR TO PERMIT ISSUANCE.
{OPTION A): LICENSED CONTRACTOR DECLARATION:
I herebyaf firm under penal tyof perjurythat I am licensed under provisionsof Chapter 9 ( commencing with Section 7000) of Division 3
of the Business and Professions Code, and my license is inf ull force and effect. I also affirm under penalty of perjury one of the
following declarations (CHOOSE ONE):
DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. Policy No. _________________________________________ _
-OR-
DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name:-----------------------•
Policy No. ____________________________ Expiration Date: _________________ ,
-OR-
D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, i shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
Interest and attorney's fees.
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: ______________________ Lender's Address: _____________________ _
CONTRACTOR CERTIFICATION: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and
utilities/utility easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are
not approved for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show
the correct dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed
use of each building as stated Is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation.
All improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME {PRINT): __________ SIGNATURE: __________ DATE: ______ _
Note: If the person signing above Is an authorized agent for the contra 'd er of authorization on contractor letterhead.
-OR-
(OPTION B): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
liJ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not Intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such
work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
-OR-
DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
-OR-
DI am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
AND,
liJ FORM B-61 "Owner Builder Acknowledgement and Verification Form" is required for any permit issued to a property owner.
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors./ understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is ovoilable upon request when this opplication is
submitted orat the following Website: http:l lwww.leginfo.ca.gov/calaw.html.
OWNER CERT/FICA T/ON: The applicant certifies that all documents and plans clearly and accurately show all existing and proposed buildings, structures, access roads, and utilities/utility
easements. All proposed modifications and/or additions are clearly labeled on the site plan. Any potentially existing detail within these plans inconsistent with the site plan are not approved
for construction and may be required to be altered or removed. The city's approval of the application is based on the premise that the submitted documents and plans show the correct
dimensions of; the property, buildings, structures and their setbacks from property lines and from one another; access roads/easements, and utilities. The existing and proposed use of each
building as stated Is true and correct; all easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. All
Improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted.
NAME (PRINT): JASON MOLGREN ~ '~·-== SIGN: :a:;-•-·--DATE: 03.27.2022 ---------------Note: If the rson sl nln above Is an authorized a ent for the ro owner include form 8-62 sl ned b owner.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558
2
Email: Building@carlsbadca.gov
REV.10/2
("Cityof
Carlsbad
OWNER-BUILDER
ACKNOWLEDGEMENT
FORM
B-61
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www .carlsbadca.gov
OWNER-BUILDER ACKNOWLEDGMENT FORM
Pursuant to State of California Health and Safety Code Section 19825-19829
To: Property Owner
An application for construction permit(s) has been submitted in your name listing you as the owner-builder of the
property located at:
Site Address 2353 JEFFERSON STREET, CARLSBAD, CA 92008
The City of Carlsbad ("City") is providing you with this Owner-Builder Acknowledgment and Verification form
to inform you of the responsibilities and the possible risks associated with typical construction activities issued
in your name as the Owner-Builder.
The City will not issue a construction permit until you have read and initialed your understanding of each
provision in the Property Owner Acknowledgment section below and sign the form. An agent of the owner
cannot execute this notice unless you, the property owner, complete the Owner's Authorized Agent form and
it is accepted by the City of carlsbad.
INSTRUCTIONS: Please read and initial each statement below to acknowledge your understanding and
verification of this information by signature at the bottom of the form. These are very important construction
related acknowledgments designed to inform the property owner of his/her obligations related to the requested
permit activities.
I. J!L I understand a frequent practice of unlicensed contractors is to have the property owner obtain an "Owner-
8uilder" building permit that erroneously implies that the property owner is providing his or her own labor and
material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries
sustained by an unlicensed contractor and his or her employees while working on my property. My homeowner's
insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of
the limits of my insurance coverage for injuries to workers on my property.
II. J!L I understand building permits are not required to be signed by property owners unless they are responsible
for the construction and are not hiring a licensed contractor to assume this responsibility.
Ill. qtf... I understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I
may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his
or her name instead of my own.
IV. JfL I understand contractors are required by law to be licensed and bonded in California and to list their license
numbers on permits and contracts.
V. ~I understand if I employ or otherwise engage any persons, other than California licensed contractors, and
the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be
considered an "employer" under state and federal law.
REV. 08/20
Owner-Builder Acknowledgement Continued
VI. J!l. I understand if I am considered an "employer" under state and federal law, I must register with the state
and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and
contribute to unemployment compensation for each "employee." I also understand my failure to abide by these
laws may subject me to serious financial risk.
VII. J!L I understand under California Contractors' State License Law, an Owner-Builder who builds single-family
residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed
by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of
the work is performed under contract with a licensed general building contractor.
VIII. qtf-. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable
for any financial or personal injuries sustained by any subsequent owner(s) which result from any latent
construction defects in the workmanship or materials.
IX. .:f!I-I understand I may obtain more information regarding my obligations as an "employer" from the Internal
Revenue Service, the United States Small Business Administration, the California Department of Benefit
Payments, and the California Division of Industrial Accidents. I also understand I may contact the California
Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information
about licensed contractors.
X. .:f!I-I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand
that I am the party legally and financially responsible for proposed construction activity at the following address:
2353 JEFFERSON STREET, CARLSBAD, CA 92008
XI. ,Jff-I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide
by all applicable laws and requirements that govern Owner-Builders as well as employers.
XII. J!L I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the
information I have provided on this form.
Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who
does not have a license, the Contractor's State License Board may be unable to assist you with any financial loss
you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court.
It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm
is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-
Builder and wish to hire contractors, you will be responsible for verifying whether or not those contractors are
properly licensed and the status of their workers' compensation coverage.
Before a building permit can be issued, this form must be completed, signed by the property owner and returned
to the City of Carlsbad Building Division.
I declare under penalty af perjury that I have read and understand all of the information pravlded an this farm and that my responses, including my
autharity ta sign this farm, is true and correct. I am aware that I have the option ta consult with /ego/ counsel prior to signing this farm, ond I have
either (1) consulted with /ego/ counsel prior ta signing this farm or (2) have waived this right in signing this farm without the advice of legal counsel.
Joel Hirschkoff 03/28/20:
Property Owner Name (PRINT) Property Owner Signature Date
2 REV.08/20
{Cityof
Carlsbad
OWNERS
AUTHORIZED
AGENT FORM
8-62
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
OWNER'SAUTHORIZED AGENT FORM
Only a property owner, contractor or their authorized agent may submit plans and applications for building
permits. To authorize a third-party agent to sign for a building permit, the owner's third party agent must bring
this signed form, which identifies the agent and the owner who s/he is representing, and for what jobs s/he
may obtain permits. The form must be completed in its entirety to be accepted by the City for each separate
permit application.
Note: The following Owner's Authorized Agent form is required to be completed by the
property owner only when designating an agent to apply for a construction permit
on his/her behalf.
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Property Owner Acknowledgement, the execution of which I understand is my personal responsibility,
I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary
to obtain an Owner-Builder Permit for my project.
ADDITION TO EXISTING S.F.R.
Scope of Construction Project (or Description of Work): ___________________ _
2353 JEFFERSON STREET, CARLSBAD, CA 92008
Project Location or Address: _____________________________ _
JASON MOLGREN (3-POINTS DESIGN+BUILD) 281.684.4871
Name of Authorized Agent: __________________ Tel No. ________ _
1506 W 10TH STREET, SAN PEDRO, CA 90732
Address of Authorized Agent: ____________________________ _
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled
out the above information and certify its accuracy.
Property Owner's Signature: Joel Hirschkoff (Mar 28, 20 7 -27 PDT)
03/28/2022
Date: ______ _
Building Permit Inspection History Finaled
{city of
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2022-1071)
Permit Type: BLDG-Residential Application Date: 03/30/2022 Owner: CO-OWNERS HIRSCHKOFF JOEL AND
HIRSCHKOFF HEATHER
Work Class: Addition Issue Date: 11/04/2022 Subdivision: LAGUNA MESA TRACTS
Status: Closed -Finaled Expiration Date: 09/25/2023 Address: 2353 JEFFERSON ST
CARLSBAD, CA 92008-1405
IVR Number: 39656
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
11/07/2022 11/07/2022 BLDG-15 Roof/ReRoof 196116-2022 Passed Chris Renfro Complete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12107/2022 12107/2022 BLDG-84 Rough 198189-2022 Failed Chris Renfro Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready. Need fire sprinkler system No
installed per plans as a deferred submittal.
Please add exhaust fan duct and smoke
detector in addition area. Call for inspection
complete
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
02124/2023 02124/2023 BLDG-84 Rough 204208-2023 Passed Dirk de Roggenbuke Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready. Need fire sprinkler system Yes
installed per plans as a deferred submittal.
Please add exhaust fan duct and smoke
detector in addition area. Call for inspection
complete
2/24/23 corrections made, ok to insulate
and drywall
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
03/28/2023 03/28/2023 BLDG-17 Interior 206470-2023 Passed Chris Renfro Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
Friday, February 23, 2024 Page 1 of 2
PERMIT INSPECTION HISTORY for (CBR2022-1071)
Permit Type: BLDG-Residential Application Date: 03/30/2022 Owner: CO-OWNERS HIRSCHKOFF JOEL AND
HIRSCHKOFF HEATHER
Work Class: Addition Issue Date: 11/04/2022 Subdivision: LAGUNA MESA TRACTS
Status: Closed -Finaled Expiration Date: 09/25/2023
IVR Number: 39656
Address: 2353 JEFFERSON ST
CARLSBAD, CA 92008-1405
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date
NOTES Created By
Angie Teanio
Status
TEXT
858-842-8063 Brent
11/29/2023 11/29/2023 BLDG-Final Inspection 231667-2023 Failed Chris Renfro
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Not ready. Need fire sign off prior to
building final.
01/23/2024 01/23/2024 BLDG-Final Inspection 237382-2024 Passed Chris Renfro
Friday, February 23, 2024
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
COMMENTS
Not ready. Need fire sign off prior to
building final.
Created Date
03/27/2023
Relnspection Incomplete
Passed
No
No
No
No
No
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 2 of 2
DATE: 8/9/2022
JURISDICTION: Carlsbad
• lW
IN TE RWEST
A SAFEbuUI COMPANY
PLAN CHECK#.: CB-CBR2022-1071.SUPP
PROJECT ADDRESS: 2353 Jefferson Street
SET: II
l r$)f PPL~!?'
,,,...., ~URI S.
PROJECT NAME: new Bedroom Addition for Hirschkoff Residence
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The check list transmitted herewith is for the applicant's information. The plans are being held at
lnterwest until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to the jurisdiction at:
~ lnterwest staff did not advise the applicant that the plan check has been completed.
D lnterwest staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Email:
Mail Telephone Fax In Person
~ REMARKS: The applicant submitted additional supporting document and made further
clarifications over the phone. Plans are being approved as a result of further clarification
discussed.
By: Richard Moreno
lnterwest
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, Californ ia 92123 ♦ (8 58) 560-1468 ♦ Fax (858) 560-1576
Hirschkoff Addition
2353 Jefferson Street
Carls bad, CA 92008
Structural Calculations -21230
Qualls Engineering
Structural E ngineering Services
Jason Molgren
130 South Cedros #220
Solana Beach, CA 9207 5
Phone: (281) 684-4871
> 1--0
Qualls Engineering
Structural Engineering Services
Correction 29:
Project: Hirschkoff Addition
Engineer: _A_L _________ _
Correction Responses
Sheet: 1/25
Job#: 21230
Date: 5/27 /22
See revised structural plan sheet SS.0 and revised detail 8/SD1 clarifying the location of beam RB-1, which is
flu sh with the low "eyebrow" roof element in coordination with the architectural plans.
Correction 30:
See revised structural plan sheet SS.0 clarifying in the stud schedule that 2X6 are the minimum stud size
reguired to comply with energy building requirements.
Correction 31:
See structural plan sheet S1.0 which clarifies and states that special inspections are reguired for "post installed
concrete expansion/ epm,1' anchors", as listed in the 'Summary of Sp ecial Inspections' table. Also, see sheet
S1.0 for the "Post-Installed Anchors" notes in coordination with the special inspections. Both the Summary
table and the notes are in coordination with CBC Chapter 17, section 107.2 and 1705.3.
Correction 36:
See revised structural plans and calculation which have incorporated the updated Geotech report prepared by
Engineering Design Group.
Note to the Engineering Reviewer:
Please feel free to reach out to me directly if there are any items that may require further consideration. We
find it is simpler and clearer to coordinate with you directly and hope to avoid another round of formal
corrections. T hanks for your partnership in providing our client the most streamlined approach possible.
Andrew Leija
andrc,1,,·(cu,q uallseng.com
760-652-9257 X 30
Qualls Engineering
Structural Engineering Services
GOVERNING CODE:
CONCRETE:
REINFORCING STEEL:
SAWN LUMBER:
ENGINEERED WOOD
Project: Hirschkoff Addition
Engineer: _A_L _________ _
DESIGN BASIS
2019 CBC
f'c = 2,500 psi (MI l'.\fUl\1)
ASTM .-\615, Fy = 60ksi
Sheet: 1A -----
Job#: 21230
Date:
DOUGLAS FIR L-\RCH, ALLOWABLE STRESS DESIGN PER 2019 CBC.
BOISE CASCADE OR EQUIVALENT
BC! WOOD "I' JOISTS -ICC-ESR 1336
BC ',(ERS.-\LAM 2.0E/L \'L/LSL -ICC-ESR 1040
PROJECT SCOPE
Project consists of a proposed approximately 345 square foot second floor addition and an
approximate 70 square foot balcony constructed over an existing one-car garage which is
attached to an existing two-story single-family residence with existing partial subterranean lower
level located at 2353 Jefferson Street, Carlsbad, CA 92008. The proposed addition and existing
residence are primarily constructed utilizing wood frame construction with 2x stick framed roof,
engineered I-Joist framing, typical raised wood floor ,vith stem wall perimeter footings, and
typical slab on grade with turned down footings. There has been a soils report provided for this
project by E ngineering D esign G roup, dated 5/20/22. Therefore, the foundation design will be
based on recomm endations o f the project geotechnical engineer.
Qualls Engineering Sheet: 2
Structural Engineering Services Project: J Jirschkoff 1\ddition Job #: _2_12_3_0 __ _
Engineer: _A_L _____________ _ Date:
Design Loads:
Pitched Roof:
Dead Load (DI.)
Roofing
1 /2" Plywood
Truss Framing
Insulation
1 /2" Gyp. Bd.
l\kch./Elec.
Misc.
5.0 psf
1.3 psf
-1.0 psf
ll.5 psf
2.2 psf
0.5 psf
___ ...,.1. __ s psf
I 0 1. = 15.o psf
LiYc Load (LL)
Floor:
Dead Load ( DL )
Flooring
3/4" Plywood
Framing
Insulation
5/8" Gyp. Bd.
l\lech./Elcc.
Misc.
9.0 psf
2.0 psf
3.(/ psf
0.5 psf
2.8 psf
1.2 psf
__ 1_.s_psf
I DL = 20.0 psf
l.i,·c Load (LL)
1.L = ____ 2_0_.0..,. psf (Reducible)
rn,+]J,=j 35.0ipsf
1.1.=
DL + LL =I 40.0 psf (Reducible)
60.0ir,sf
Walls:
Srud Walls
Exterior Stud WalJs
Interior Srud Walls
Allowable Soils Bearing Pressure:
l:'i.t' psf
7.u psf
Deck:
Dead Load ( DL )
Dcx-O-Tcx
3/4" Plywood
2.5 psf
2.0 psf
3.0 psf rraming
Stucco
Misc.
10.0 psf
2 . .5 psf
I DL = ~ psf
J.i\"e Load (LI.)
I.L =
DL + LL=j
6ll.0 psf (Reducible)
80.0jpsf
ASBP = 2,(J00 psf@ 18 inches below lowest adjacent finished grade
Seismic:
Site Class: D
S5 = I.052
S1 = 0.382
I\= 1.201
I\=.
Response
Occupancy Importance l\lod. Factor
Category Factor, 1,
1l ).(10
Wind Load: (Simplified Envelope Procedure)
Basic Wind 95 mph
1-<'.xpow rc: L)
MWFRS
P = 0.6*1'.*K,.,*Ps30
(LIU"D): P =
(ASD): p =I 21.3 psf
12.8lpsf
Components & Cladding
P = 0.6*1'.*K,./Pnct30
(LJU,D): P =
(ASD): p =I 26.1 psf
15.61psf
R
6.5
1-.=
K zr =
P,30=
pnet30=
SMs = 1.263
s~,, = -
Redundancy pCs
l"actor SD,/(R/1)
p (LRl'l)j (.\SD)
1 . .3 0.168 j 0.120
1.61
1.0
1.\2
16.2
0.842
Qualls Engineering Project Title: Hirschkoff Addition
Engineer: AL 4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Project ID: 21230
Project Descr:
3
Printed: 6 JAN 2022, 6:57PM
Wood Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 ,.,
DESCRIPTION: RR-1
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
•
Analysis Method : Allowable Stress Design
Load CombinationASCE 7-16
Fb + 1,000.0 psi
1,000.0 psi
1,500.0 psi
E : Modulus of Elasticity
Wood Species : Douglas Fir-Larch
Wood Grade : No. 1
Beam Bracing : Beam bracing is defined Beam-by-Beam
Unbraced Lengths
Span # 1, Defined Brace Spacing, First Brace at ft and spaced at 2.0 ft
Span # 2. Fully Braced
Span = 2.0 ft
Fb-
Fc-Prll
Fe -Perp
Fv
Ft
625.0 psi
180.0 psi
675.0 psi
D(0.01995) Lr(0.0266) •
2x10
Span= 14.0 ft
Ebend-xx 1,700.0ksi
Eminbend -xx 620.0 ksi
Density 31 .21 Opd
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load : D = 0.0150, Lr= 0.020 ksf, Tributary Width= 1.330 ft, (ROOF)
Load for Span Number 2
Uniform Load: D = 0.0150, Lr = 0.020 ksf, Tributary Width = 1.330 ft, (ROOF)
DESIGN SUMMARY
Maximum Bending Stress Ratio 0.475 1 Maximum Shear Stress Ratio
Section used for this span 2x10 Section used for this span
fb: Actual = 653.60psi fv: Actual
Fb: Allowable 1,375.00psi Fv: Allowable
Load Combination +D+Lr Load Combination
Location of maximum on span 7.117ft Location of maximum on span
Span # where maximum occurs = Span# 2 Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection 0.131 in Ratio= 1281 >=240
Max Upward Transient Deflection -0.057 in Ratio= 844>=240
Max Downward Total Deflection 0.244 in Ratio= 687 >=180
Max Upward Total Deflection -0.106 in Ratio= 452 >=180
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Moment Values
Segment Length Span# M V Cd C FN Cj Cr Cm Ct CL M fb
D Only
Length= 2.0 ft 1 0.024 0.089 1.00 1.100 1.00 1.00 1.00 1.00 0.98 0.05 25.76
Length= 14.0 ft 2 0.275 0.089 1.00 1.100 1.00 1.00 1.00 1.00 1.00 0.54 302.78
+D+Lr 1.100 1.00 1.00 1.00 1.00 1.00
Length = 2.0 ft 1 0.042 0.153 1.25 1.100 1.00 1.00 1.00 1.00 0.97 0.10 55.60
Length= 14.0 ft 2 0.475 0.153 1.25 1.100 1.00 1.00 1.00 1.00 1.00 1.17 653.60
+D+0.750Lr 1.100 1.00 1.00 1.00 1.00 1.00
Design OK
= 0.153 : 1
2x10
= 34.50 psi
225.00 psi
+D+Lr
= 2.000ft
= Span# 1
Shear Values
F'b V fv F'v
0.00 0.00 0.00 0.00
1077.52 0.15 15.98 180.00
1100.00 0.15 15.98 180.00
0.00 0.00 0.00 0.00
1336.56 0.32 34.50 225.00
1375.00 0.32 34.50 225.00
0.00 0.00 0.00 0.00
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Wood Beam
1,1
DESCRIPTION: RR-1
Load Combination
Segment Length Span#
Length = 2.0 ft 1
Length= 14.0 ft 2
Max Stress Ratios
M V
0.036 0.133
0.412 0.133
Overall Maximum Deflections
Load Combination
-+O+Lr
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
D Only
-+0-+lr
-+0+0.750Lr
Lr Only
Span
1
2
Project Title: Hirschkoff Addition
Engineer: AL
Project ID: 21230
Project Descr:
4
Printed· 6 JAN 2022, 6: 57PM
Software copyrigtlt ENERCALC, INC. 1983-2020,
•..
Moment Values Shear Values
Cd C FN Ci Cr Cm Ct CL M lb F'b V Iv F'v
1.25 1.100 1.00 1.00 1.00 1.00 0.97 0.09 48.14 1336.56 0.28 29.87 225.00
1.25 1.100 1.00 1.00 1.00 1.00 1.00 1.01 565.90 1375.00 0.28 29.87 225.00
Max. "-' Defl Location in Span Load Combination Max.'+" Defl Location in Span
0.0000 0.000 -+0-+lr -0.1059 0.000
0.2443 7.117 0.0000 0.000
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2 Support 3
0.453 0.340
0.243 0.182
0.210 0.157
0.453 0.340
0.392 0.294
0.243 0.182
Qualls Engineering Project Title: Hirschkoff Addition
Engineer: AL 4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Project ID: 21230
Project Descr:
Printed: 6 JAN 2022. 9:40AM r---------------------------------------...ile:11irsi:hkoff Add1~
Wood Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 ,.,
DESCRIPTION: RB-1
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination ASCE 7-16
Wood Species : Boise Cascade
Wood Grade : Versa Lam 3100
Beam Bracing : Beam bracing is defined Beam-by-Beam
Unbraced Lengths
Span# 1, Fully Braced
Span # 2, Defined Brace Spacing, First Brace at ft and spaced at 4.250 ft
• D(0.03) Lr(0.04)
3.5x11 .875
Span = 15.50 fl
Fb+
Fb-
Fc -Prll
Fe -Perp
Fv
Ft
3,100.0psi
3,100.0 psi
3,000.0psi
750.0psi
285.0psi
2, 100.0psi
. .
E : Modulus of Elasticity
Ebend-xx 2,000.0ksi
Eminbend -xx 1,036.83ksi
Density 41. 760pcf
• 9(0.12).lr(0.16) •
~ 3.5x1 1.875
Span = 4.250 fl
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load : D = 0.0150, Lr= 0.020 ksf, Tributary Width= 2.0 ft, (ROOF)
Load for Span Number 2
Uniform Load : D = 0.0150, Lr= 0.020 ksf, Tributary Width= 8.0 ft, (ROOF)
DESIGN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
fb: Actual
Fb: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Overall Maximum Deflections
Load Combination
+D+lr
+D+lr
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
DOnly
+D+lr
+D..0.750Lr
Lr Only
Span
-~1
2
=
=
=
=
0.101: 1 Maximum Shear Stress Ratio
3.5x11 .875 Section used for this span
384 46osi fv: Actual
3,789.73psi Fv: Allowable
+D+Lr Load Combination
0.000ft Location of maximum on span
Span #2 Span # where maximum occurs
0.021 in Ratio= 4870>=240
0.000 in Ratio = 0<240
0.028 in Ratio= 3682>=180
-0.000 in Ratio= 319926 >=180
Max."-" Defl Location in Span Load Combination
0.0416 6.408
0.0277 4.250
Support notation : Far left is #1
Support 1
0.466
0.217
0.249
0.466
0.412
0.217
Support 2 Support 3
2.047
1.083
0.964
2 047
1.777
1.083
=
=
Design OK
0.097 : 1
3.5x11 .875
34.52 psi
356.25 psi
+D+Lr
15.500ft
Span# 1
Max."+" Defl Location in Span
0.0000 0.000
0.0000 0.000
Values in KIPS
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Project Title: Hirschkoff Addition
Engineer: AL
Project ID: 21230
Project Descr:
6
Printed: 6 JAN 2022. 9 41AM
r-w ___ d_B-------------------------------------,.,ile-,-,-:"1.-:rs=coffAddillon.ec6
t OO earn Software copyright ENERCALC, INC. 1983-2020, Bulld:12.20,8.24
1.t • •
DESCRIPTION: RB-2
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design Fb +
Load Combination ASCE 7-16 Fb -
Fe -Prll
Wood Species : Boise Cascade Fe -Perp
Wood Grade : Versa Lam 3100 Fv
Ft
Beam Bracing : Beam bracing is defined Beam-by-Beam
Unbraced Lengths
Span# 1, Defined Brace Spacing, First Brace at ft and spaced at 2.0 ft
Span # 2, Defined Brace Spacing, First Brace at ft and spaced at 4.250 ft
D(0.96) Lr(1.08)
3,100.0 psi
3,100.0psi
3,000.0 psi
750.0psi
285.0psi
2,100.0 psi
D( .01995 Lr 0.0266 D 0.01995 Lr 0.0266
3.5x11.875 ~
Span= 2.0 ft
3.5x11.875
Span = 14.0 ft
•
E : Modulus of Elasticity
Ebend-xx 2,000.0ksi
Eminbend -xx 1,036.83 ksi
Density 41. 760pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load: D = 0.0150, Lr = 0.020 ksf, Tributary Width= 1.330 ft, (ROOF)
Point Load : D = 0.960, Lr= 1.080 k@ 0.0 ft, (RB-1)
Load for Span Number 2
Uniform Load: D = 0.0150, Lr= 0.020 ksf, Tributary Width= 1.330 ft, (ROOF)
DESIGN SUMMARY
Maximum Bending Stress Ratio =
Section used for this span
fb: Actual =
Fb: Allowable =
Load Combination
Location of maximum on span =
Span# where maximum occurs =
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Overall Maximum Deflections
Load Combination
-+O+Lr
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
D Only
-+O+Lr
-+0+0.750Lr
Lr Only
Span
1
2
0.161 1 Maximum Shear Stress Ratio
3.5x11.875 Section used for th is span
611.78psi fv: Actual
3. 790.46psi Fv: Allowable
+D+Lr Load Combination
0.000ft Location of maximum on span
Span #2 Span# where maximum occurs
0.031 in Ratio= 1550 >=240
-0.027 in Ratio = 6120 >=240
0.055 in Ratio= 866>=180
-0.046 in Ratio= 3684>=180
Max.•-• Defl Location in Span Load Combination
0.0554 0.000
0.0000 0.000 -+O+Lr
Support notation : Far left is #1
Support 1 Support 2 Support 3
2.867 0.110
1.477 0.028
1.390 0.082
2.867 0.110
2.498 0.103
1.477 0.028
=
=
=
=
Design OK
0.213: 1
3.5x11.875
75.74 psi
356.25 psi
+D+Lr
1.017ft
Span# 1
Max.'+" Defl Location in Span
0.0000 0.000
-0.0456 4.693
Values in KIPS
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Project Title: Hirschkoff Addition
Engineer: AL
Project ID: 21230
Project Descr:
Printed: 6 jAN 2022, 9:41AM
Wood Beam Software copyright ENERCALC, INC 1983-2020, Buiid:12.20.8.24 ,.,
DESCRIPTION: RB-3
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design Fb +
Load Combination ASCE 7-16 Fb -
Fe-Prll
Wood Species : Boise Cascade Fe· Perp
Wood Grade : Versa Lam 3100 Fv Ft
Beam Bracing : Beam bracing is defined Beam-by-Beam
Unbraced Lengths
Span # 1, Fully Braced
Span # 2, Defined Brace Spacing, First Brace at ft and spaced at 4.250 ft
D(0.12) Lr(0.16)
5.25x11.875
Span = 7 .250 ft
3,100.0 psi
3,100.0 psi
3,000.0psi
750.0 psi
285.0psi
2,100.0psi
•
E : Modulus of Elasticity
Ebend-xx 2,000.0ksi
Eminbend • xx 1,036.83ksi
Density 41. 760pcf
D(0.12) Lr(0.16)
5.25x11 .875
Span = 4.250 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load: D = 0.0150, Lr = 0.020 ksf, Tributary Width = 8.0 ft, (ROOF)
Load for Span Number 2
Uniform Load : D = 0.0150, Lr = 0.020 ksf, Tributary Width = 8.0 ft, (ROOF)
DESIGN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
fb: Actual
Fb: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Maximum Deflection Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Overall Maximum Deflections
Load Combination
+O-+lr
+D-+lr
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
D Only
Span
1
2
0.068 1
5.25x11.875
261.81 psi
3,843.76psi
+D+Lr
0.000ft
Span #2
Maximum Shear Stress Ratio
Section used for this span
fv: Actual
0.012 in Ratio=
0.000 in Ratio=
0.023 in Ratio=
-0.001 in Ratio=
Fv: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
8202>=240
0<240
4402 >=180
114217 >=180
Max.•.• Defl Location in Span Load Combination
0.0028 2.552 ~r
0.0232 4.250
Support 1
0.709
0.381
0.329
Support notation : Far left is #1
Support 2 Support 3
2.719
1.459
1.259
Desi n OK
0.078 : 1
5.25x11.875
27.96 psi
356.25 psi
+D+Lr
6.278ft
Span# 1
Max. • +" Defl Location in Span
-0.0008 6.440
0.0000 6.440
Values in KIPS
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
LWood Beam
1,1
DESCRIPTION: RB-3
Vertical Reactions
Load Combination
+D+Lr
+D..0.750Lr
Lr Only
Support 1
0.709
0.614
0.381
Project Title: Hirschkoff Addition
Engineer: AL
Project ID: 21230
Project Descr:
8
Printed: 6 JAN 2022, 9:41AM
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 •.
Support notation : Far left is #1 Values in KIPS
Support 2 Support 3
2.719
2.354
1.459
Qualls Engineering Project Title: Hirschkoff Addition
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Engineer: AL
Project ID: 21230
Project Descr:
9
Printed· 6 JAN 2022, 9:42AM
Wood Beam File: Hirs koff Addition.ec6
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 ,.,
DESCRIPTION: RH-1 HIGH
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination ASCE 7-16
Wood Species
Wood Grade
: Boise Cascade
: Versa Lam 3100
Fb +
Fb -
Fe -Prll
Fe -Perp
Fv
Ft
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D0.12 Lr0.16
£ 5.25x9.25
Span = 11 . 50 ft
3,100.0 psi
3,100.0 psi
3,000.0 psi
750.0psi
285.0 psi
2,100.0 psi
. .
E ; Modulus of Elasticity
Ebend-xx 2,000.0ksi
Eminbend -xx 1,036.83ksi
Density 41 .760pcf
~
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load : D = 0.0150, Lr= 0.020 ksf, Tributary Width = 8.0 ft, (Roo0
DESIGN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
fb: Actual
Fb: Allowable
Load Combination
Location of maximum on span
Span# where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection Max Upward Total Deflection
Overall Maximum Deflections
Load Combination Span
+D+lr 1
Vertical Reactions
Load Combination
OverafMAXimum
Overall MINimum
DOnly
+D+lr
+0+0.750Lr
Lr Only
0.201: 1 Maximum Shear Stress Ratio
5.25x9.25 Section used for this span
779.23psi fv: Actual
3.875.00psi Fv: Allowable
+D+Lr Load Combination
5.750ft Location of maximum on span
Span# 1 Span# where maximum occurs
0.091 in Ratio= 1509 >=240
0.000 in Ratio= 0<240
0.168 in Ratio= 820 >=180
0.000 in Ratio= 0<180
Max.'-' Defl Location in Span Load Combination
0.1681 5.792
Support notation : Far left is #1
Support 1 Support 2
1.691 1.691
0.920 0.920
0.771 0.771
1.691 1.691
1.461 1.461
0.920 0.920
=
=
=
=
Design OK
0.127 : 1
5.25x9.25
45.37 psi
356.25 psi
+D+Lr
0.000ft
Span# 1
Max. '+' Defl Location in Span
0.0000 0.000
Values in KIPS
~ Boise Cascade' ~ w EhGINEEREO W000 ffiOOUCTS
Single 11-7/8" BCI® 5000-1.7 OF
J01 (Joist)
BC CALC® Member Report
Build 8104
Dry 11 span I No cant. I 16 OCS I Repetitive I Glued & nailed
Job name: HIRSCHKOFF ADDITION File name:
Address: Description: FJ-1
CG
QE
City, State, Zip: Specifier:
Customer: Designer:
Code reports: ESR-1336 Company:
• 1 •
r------,
14-00-00
B1
Total Horizontal Product Length = 14-00-00
Reaction Summary (Down I Uplift) (lbs)
Bearing Live Dead Snow Wind
B1 ,3-1/2" 373/0 187 /0
B2,3-1/2" 373/0 187 /0
Load Summary
Tag Descrietion Load T:i'.ee Ref. Start End
1 Floor Load Unf. Area (lb/ft2) L 00-00-00 14-00-00
Controls Summary Value
Pos. Moment 1834 ft-lbs
End Reaction 560Ibs
End Shear 537Ibs
Total Load Deflection U786 (0.207")
Live Load Deflection U1180 (0. 138")
Max Deft. 0.207"
NBCC Vibration 13'-5"
Span/ Depth 13.7
Bearing Supports Dim. (LxW)
B1 Wall/Plate 3-1/2" x 2"
B2 Wall/Plate 3-1/2" x 2"
% Allowable
58.2%
39.3%
33.0%
30.5%
30.5%
20.7%
78.5%
Value
560 Ibs
560 Ibs
%Allow
sueeort
n\a
n\a
BC FloorValue® and NBCC Vibration Summary
Duration
100%
100%
100%
n\a
n\a
n\a
n\a
%Allow
Member
39.3%
39.3%
BC FloorValue®: ®i¥t1¥%Wifi#Mi&Ml¥@iittitM# Subfloor: 3/4" OSB, Glue + Nail
Minimum Enhanced Premium Gypsum Ceiling: None
Controlling Location: 07-00-00 Bracing: None
Subfloor Rating: Premium Strapping: None
Notes
Design meets Code minimum (U240) Total load deflection criteria.
Design meets Code minimum (U360) Live load deflection criteria.
Design meets arbitrary (1") Maximum Total load deflection criteria.
BC CALC® analysis is based on IBC 2009.
Live Dead
Loe. 100% 90%
Top 40 20
Case Location
1 07-00-00
00-00-00
00-03-08
07-00-00
2 07-00-00
1 07-00-00
00-00-00
Material
Unspecified
Unspecified
Composite El value based on 3/4" thick OSB sheathing glued and nailed to member.
Design based on Dry Service Condition.
Calculations assume member is fully braced.
Page 1 of 1
14 ;JI PASSED I
January 6, 2022 19:26:04
B2
Roof Live
Snow Wind Roof ocs
Live
115% 160% 125%
16
Disclosure
Use of the Boise Cascade Software is
subject to the terms of the End User
License Agreement (EULA).
Completeness and accuracy of input
must be reviewed and verified by a
qualified engineer or other appropriate
expert to assure its adequacy. prior to
anyone relying on such output as
evidence of suitability for a particular
application. The output here is based on
building code-accepted design
properties and analysis methods.
Installation of Boise Cascade
engineered wood products must be in
accordance with current Installation
Guide and applicable building codes. To
obtain Installation Guide or ask
questions. please call (800)232-0788
before installation.
BC CALC®, BC FRAMER®. AJS™.
ALLJOIST® . BC RIM BOARD TM, BCI® ,
BOISE GLULAM™, BC FloorValue®,
VERSA-LAM®, VERSA-RIM PLUS®,
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Project Title: Hirschkoff Addition
Engineer: AL
Project ID: 21230
Project Descr:
11
Printed: 6 JAN 2022. 9:55AM
File: irs o 1bon.e Wood Beam Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 ,.,
DESCRIPTION: DB-1
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination ASCE 7-16
Fb+
Fb -
Fc -Prll
Wood Species : Boise Cascade Fe -Perp
Wood Grade : Versa Lam 3100 Fv
Ft
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D(0.0350)
•D(0:041L(0.12)
525~5 1 S.25x9.5
Span= 2.0 ft Span = 14.0 ft
3,100.0psi
3,100.0psi
3,000.0 psi
750.0 psi
285.0psi
2,100.0 psi
..
E: Modulus of Elasticity
Ebend-xx 2,000.0 ksi
Eminbend -xx 1,036.83 ksi
Density 41. 760 pct
Repetitive Member Stress Increase
Applied Loads SeNice loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Loads on all spans ...
Uniform Load on ALL spans : D = 0.0350 k/ft
Load for Span Number 1
Uniform Load : D = 0.020, L = 0.060 ksf, Tributary Width = 8.0 ft, (DECK)
Load for Span Number 2
Uniform Load : D = 0.020, L = 0.060 ksf, Tributary Width= 2.0 ft, (DECK)
DESIGN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
fb: Actual
Fb: Allowable
0.232 1
5.25x9.5
= 748 32psi
= 3.224.00psi
Maximum Shear Stress Ratio
Section used for this span
fv: Actual
Load Combination
Location of maximum on span
Span # where maximum occurs
+D+L +H, LL Comb Run (*L)
= 7.117ft
Fv: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Overall Maximum Deflections
Load Combination
+D+L +H, LL Comb Run (*L)
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
+D+L +H, LL Comb Run ('L)
+D+L +H, LL Comb Run (L*)
Span
1
2
Span# 2
0.140 in
-0.063 in
0.232 in
-0.100 in
Ratio = 1204 >=360
Ratio = 7 58 >=360
Ratio= 725 >=240
Ratio= 478 >=240
Max. • -• Deft Location in Span Load Combination
0.0000 0.000 +D+L +H, LL Comb Run ('l)
0.2315 7.117
Support notation : Far left is #1
Support 1 Support 2 Support 3
2.944 1.436
1.869 0.771
1.915 1.436
2.104 0.528
Design OK
0.148 : 1
5.25x9.5
= 42.13psi
285.00 psi
+D+L+H, LL Comb Run (LL)
2.000ft
Span# 1
Max."+" Deft Location in Span
-0.1004 0.000
0.0000 0.000
Values in KIPS
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Wood Beam ... . .
DESCRIPTION: DB-1
Vertical Reactions
Load Combination
-+D+L +H, LL Comb Run (LL)
-+D+Lr+H, LL Comb Run (•L)
-+D+Lr+H, LL Comb Run (L •)
-+D+Lr+H, LL Comb Run (LL)
-+D.0.750Lr.0.750L +H, LL Comb Run (•
-+D.O. 750Lr.0.750L +H, LL Comb Run (L
-+D.O. 750Lr.0.750L +H, LL Comb Run (L
-+D.O. 750L .0.750S+H, LL Comb Run (•L
-+D.0.750L.0.750S+H, LL Comb Run (L'
-+D.0.750L .0.750S+H, LL Comb Run (LL
DOnly
L Only, LL Comb Run (•L)
L Only, LL Comb Run (L•)
L Only, LL Comb Run (LL)
Project Title: Hirschkoff Addition
Engineer: AL
Project ID: 21230
12
Project Descr:
Pnnted: 6 JAN 2022, 9:55AM
Software copyright ENERCALC, INC. 1983-2020, Bulld:12.20,8.24 •
Support notation : Far left is #1 Values in KIPS ----Support 1 Support 2 Support 3
2.944 1.368
1.075 0.596
1.075 0.596
1.075 0.596
1.705 1.226
1.847 0.545
2.477 1.175
1.705 1.226
1.847 0.545
2.477 1.175
1.075 0.596
0.840 0.840
1.029 -0.069
1.869 0.771
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Project Title: Hirschkoff Addition
Engineer: AL 13
Project ID: 21230
Project Descr:
Printed: 6 JAN 2022. 10:<16AM
Wood Beam Software copynghl ENERCALC, INC. 1983-2020, Bulld:12.20.8.24 , ..
DESCRIPTION: DB-2
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination ASCE 7-16
Wood Species
Wood Grade
: Boise Cascade
: Versa Lam 3100
Fb+
Fb-
Fc-Prll
Fe• Perp
Fv
Ft
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
0(0.0350)
O(1.0B) L(1.87)
D 0.0266 L 0.0798
5.250 X 9.50
Span = 4.250 ft
3,100.0 psi
3,100.0psi
3,000.0psi
750.0psi
285.0psi
2,100.0psi
0(0.15/ • D(0.14) L(0.28)
5. 25x 11.875
Span = 11.250 ft
. .
E : Modulus of Elasticity
Ebend-xx 2,000.0ksi
Eminbend • xx 1,036.83 ksi
Density 41 . 760 pct
Repetitive Member Stress Increase
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Loads on all spans ...
Uniform Load on ALL spans : D = 0.0350 k/ft
Load for Span Number 1
Uniform Load : D = 0.020, L = 0.060 ksf, Tributary Width= 1.330 ft, (DECK)
Point Load : D = 1.080, L = 1.870 k @ 0.0 ft, (DB-1)
Load for Span Number 2
Uniform Load : D = 0.020, L = 0.040 ksf, Tributary Width= 7.0 ft, (FLOOR)
Uniform Load : D = 0.150, Tributary Width= 1.0 ft, (WALL)
DESIGN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
fb: Actual
0.657. 1
5.250 X 9.50
= 2,1 19.09psi
Maximum Shear Stress Ratio
Section used for this span
fv: Actual
Fb: Allowable = 3.224 OOpsi
+D+L+f-i, LL Comb Run {L•)
= 4150ft
Load Combination
Fv: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Overall Maximum Deflections
Load Combination
+D+L+H,L L Comb Run (L•)
+D+L +H, LL Comb Run (•L)
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
Span
1
2
= Span#1
0.281 in
-0.083 in
0.349 in
-0.056 in
Ratio=
Ratio=
Ratio=
Ratio=
Max.•.• Defl Location in Span
0.3494 0.000
0.1052 5.971
Location of maximum on span
Span # where maximum occurs
362 >=360
1224 >=360
290 >=240
2390 >=240
Load Combination
L Only, LL Comb Run (L •)
Support notation : Far left is #1
Support 1 Support 2 Support 3
8.357 3.036
4.555 0.804
Design OK
0.439 : 1
5.250 X 9.50
= 125.02 psi
285.00 psi
+D+L +f-i, LL Comb Run (LL)
= 4.250ft
= Span# 1
Max."+" Defl Location in Span
0.0000 0.000
-0.0775 3.331
Values in KIPS
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Wood Beam
', ..
DESCRIPTION: DB-2
Vertical Reactions
Load Combination
+0-+l +H, LL Comb Run (•L)
+D-+l +H, LL Comb Run (L •)
+0-+l +H, LL Comb Run (LL)
+0-+lr+H, LL Comb Run ('L)
+0-+lr+H, LL Comb Run (L•)
+0-+lr+H, LL Comb Run (LL)
+0+0.750Lr+0.750L+H, LL Comb Run('
+0+0.750Lr+0.750L+H, LL Comb Run (L
+0+0.750Lr+0.750L+H, LL Comb Run (L
+O+O. 750L +0.750S+H, LL Comb Run ('L
+0+0.750L+0.750S-+l-l, LL Comb Run (L•
+0+0.750L+0.750S-+l-l, LL Comb Run (LL
DOnly
L Only, LL Comb Run (•L)
L Only, LL Comb Run (L •)
L Only, LL Comb Run (LL)
Support 1
Project Title: Hirschkoff Addition
Engineer: AL
Project ID: 21230
14
Project Descr:
Printed. 6 JAN 2022. 10"46AM
Software copyright ENERCALC, INC. 198~2020, 8uild:1 •.
Support notation : Far left is #1 Values in KIPS
Support2
5.377
6.782
8.357
3.802
3.802
3.802
4.983
6.037
7.218
4.983
6.037
7.218
3.802
1.575
2.980
4.555
Support 3
3.036
0.690
2.265
1.461
1.461
1.461
2.642
0.883
2.064
2.642
0.883
2064
1.461
1.575
-0.771
0.804
Qualls Engineering Project Title: Hirschkoff Addition
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Engineer: AL
Project ID: 21230
Project Descr:
15
Printed: 6 JAN 2022. 10:45AM
Wood Beam Software copyright ENERCALC, INC. 1983-2020, Bu!ld:12.20.8.24
1 ,1
DESCRIPTION: 08-3
CODE REFERENCES ---
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination ASCE 7-16
Fb+
Fb-
Fc -Prll
Wood Species : Boise Cascade Fe · Perp
Wood Grade : Versa Lam 3100 Fv Ft
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D 0.0350
0(0.6) (0.84)
D 0.0266 L 0.0798
5.250 X 9.50
Span = 4.250 ft
3,100.0psi
3,100.0psi
3,000.0psi
750.0psi
285.0psi
2,100.0psi
5.25x11.875
Span = 11.250 ft
..
E : Modulus of Elasticity
Ebend-xx 2,000.0ksi
Eminbend -xx 1,036.83ksi
Density 41 . 760 pcf
Repetitive Member Stress Increase
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Loads on all spans ...
Uniform Load on ALL spans : D = 0.0350 k/ft
Load for Span Number 1
Uniform Load : D = 0.020, L = 0.060 ksf, Tributary Width = 1.330 ft, (DECK)
Point Load : D = 0.60, L = 0.840 k @ 0.0 ft, (DB-1)
Load for Span Number 2
Uniform Load : D = 0.020, L = 0.040 ksf, Tributary Width= 7.0 ft, (FLOOR)
Uniform Load : D = 0.150, Tributary Width= 1.0 ft, (WALL)
Point Load : D = 0.330, Lr= 0.380 k@ 7.0 ft, (RB-3)
DESIGN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
fb: Actual
0.355 1
5.250 X 9.50
1. 143 89psi
3,224 OOpsi
+D+L+H, LL Comb Run (L*)
Maximum Shear Stress Ratio
Section used for this span
fv: Actual
Fb: Allowable
Load Combination
Location of maximum on span
Span# where maximum occurs
Maximum Deflection Max Oo\Mlward Transient Deflection
Max Upward Transient Deflection
Max Do\Mlward Total Deflection
Max Upward Total Deflection
Overall Maximum Deflections
Load Combination
L Only, LL Comb Run (L *)
+04. +H, LL Comb Run (*L)
Vertical Reactions
Load Combination
Overall MAXimum
Span
1
2
= 4.250ft
= Span# 1
0.138 in
-0.083 in
0.128 in
-0.093 in
Ratio =
Ratio=
Ratio=
Ratio =
Max."·" Defl Location in Span
0.1379 0.000
0.1349 5.845
Fv: Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
738 >=360
122.4>=360
796>=240
1096>=240
Load Combination
+04. +H, LL Comb Run (*L)
Support notation . Far left is #1
Support 1 Support 2 Support 3
6.401 3.422
Desi n OK
= 0.392 : 1
5.250 X 9.50
= 111 .62psi
285.00 psi
+D+L+H, LL Comb Run (LL)
= t250ft
= Span# 1
Max. "+" Defl Location in Span
-0.0458 2.517
0.0000 2.517
Values in KIPS
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Wood Beam
1 ,1
DESCRIPTION: D8-3
Vertical Reactions
Load Combination
Overall MINimum
+D+l +H, LL Comb Run ('L)
+D+l +H, LL Comb Run (L ')
+D+l +H, LL Comb Run (LL)
+D+lr+H, LL Comb Run ('L)
+D+lr+H, LL Comb Run (L')
+D+lr+H, LL Comb Run (LL)
+D+O. 750Lr-+-0.750L +H, LL Comb Run ('
+D+0.750Lr-+-0.750L+H, LL Comb Run (L
+D+0.750Lr+0.750L+H, LL Comb Run (L
+D+0.750L+0.750S+H, LL Comb Run ('L
+D+0.750L+0.750S+H, LL Comb Run (L'
+D+0.750L+0.750S+H, LL Comb Run (LL
DOnly
Lr Only, LL Comb Run ('L)
Lr Only, LL Comb Run (LL)
L Only, LL Comb Run ('L)
L Only, LL Comb Run (L ')
L Only, LL Comb Run (LL)
Project Title: Hirschkoff Addition
Engineer: AL 16
Project ID: 21230
Project Descr:
Support notation : Far left is #1
Support 1 Support 2 Support 3
3.136 1.194
4.840 3.422
4.826 1.466
6.401 3.041
3.409 2 084
3.265 1.847
3.409 2.084
4.554 3.206
4.436 1.561
5.725 2.920
4.447 3.029
4.436 1.561
5.617 2.743
3.265 1.847
0.144 0.236
0.144 0.236
1.575 1.575
1.561 -0.381
3.136 1.194
Printed: 6 JAN 2022. 10"45AM
File: irschkoff Addition.ec6
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 •
Values in KIPS
Qualls Engineering Project Title: Hirschkoff Addition
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Engineer: AL
Project ID: 21230
Project Descr:
17
Wood Beam
Pnntecl: 6 JAN 2022. 10:45AM
ile: AirschkoffAddilion.ec:6-
Sottware copyright ENERCALC, INC. 1983-2020, Bulkl:12.20.8.24
1,1
DESCRIPTION: DB-4
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method: Allowable Stress Design
Load Combination ASCE 7-16
Wood Species
Wood Grade
: Boise Cascade
: Versa Lam 3100
Fb +
Fb -
Fc-Prll
Fe -Perp
Fv
Ft
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
3,100.0 psi
3,100.0 psi
3,000.0 psi
750.0 psi
285.0 psi
2,100.0 psi
•..
E: Modulus of Elasticity
Ebend-xx 2,000.0ksi
Eminbend -xx 1,036.83ksi
Density 41 . 760 pcf
Repetitive Member Stress Increase
0(0 12) D 0_ 16 L 0.48 ,.----------. • .--------D=(Oc..:.0:..::2:.::6.::.6,_)0L=i(..::.O:..::.Oc::5.::.32=..),.___ _____ ,,0 ----------,•
1.75x9.5 1. 750 X 11.875
Span = 2.0 ft Span= 14.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load: D = 0.020, L = 0.060 ksf, Tributary Width= 8.0 ft, (DECK}
Point Load: D = 0.120 k @0.0 ft, (RIM}
Load for Span Number 2
Uniform Load : D = 0.020, L = 0.040 ksf, Tributary Width= 1.330 ft, (DECK}
DESIGN SUMMARY
Maximum Bending Stress Ratio 0.216 1 Maximum Shear Stress Ratio
Section used for this span 1.75x9.5 Section used for this span
fb: Actual 697.33psi fv: Actual
Fb: Allowable = 3,224.00psi Fv: Allowable
Load Combination +D+L +H, LL Comb Run (LL) Load Combination
2.000ft Location of maximum on span Location of maximum on span
Span# where maximum occurs
Maximum Deflection Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Overall Maximum Deflections
Load Combination
-+O+L +H, LL Comb Run ('L)
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
-+O+L +H, LL Comb Run (*L)
-+O+L-+l-1, LL Comb Run (L*)
-+O+L-+l-1, LL Comb Run (LL)
Span
1
2
= Span# 1
0.038 in Ratio=
-0.043 in Ratio=
0.128 in Ratio=
-0.046 in Ratio=
Max. '-' Defl Location in Span
0.0000 0.000
0.1283 7.196
Span # where maximum occurs
1250>=360
1114>=360
1309>=240
1040>=240
Load Combination
-+O+L-+l-1, LL Comb Run (*L)
Support notation : Far left is #1
Support 1 Support 2 Support 3
2.120 0.560
1.401 0.304
1.091 0.560
1.747 0.119
2.120 0.492
Design OK
= 0.287 : 1
1.75x9.5
= 81 .68 psi
= 285.00 psi
+D+l +H, LL Comb Run (LL)
= 1.218ft
= Span# 1
Max.'+' Defl Location in Span
-0.0461 0.000
0.0000 0.000
Values in KIPS
Qualls Engineering
4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Wood Beam
1 ,1
DESCRIPTION: DB-4
Vertical Reactions
Load Combination
-+D+lr-+f-t, LL Comb Run (*L)
-+D+lr-+f-t, LL Comb Run (L ')
-+D+lr-+f-t, LL Comb Run (LL)
-+D-+-0.750Lr-+-0.750L-+f-t, LL Comb Run ('
-+D-+-0.750Lr-+-0.750L-+f-t, LL Comb Run (L
-+D-+-0.750Lr-+-0.750L-+f-t, LL Comb Run (L
-+D-+-0.750L-+-0.750S-+f-t, LL Comb Run ('L
-+D-+-0.750L-+-0.750S-+f-t, LL Comb Run (L'
-+D-+-0.750L-+-O. 750S-+f-t, LL Comb Run (LL
D Only
L Only, LL Comb Run ('L)
L Only, LL Comb Run (L ')
L Only, LL Comb Run (LL)
Project Title: Hirschkoff Addition
Engineer: AL
Project ID: 21230
Project Descr:
18
Printed: 6 JAN 2022. 10'45AM
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 •
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2 Support 3
0.719 0.188
0.719 0.188
0.719 0.188
0.998 0.467
1.490 0.136
1.769 0.416
0.998 0.467
1.490 0.136
1.769 0.416
0.719 0.188
0.372 0.372
1.029 -0.069
1.401 0.304
Qualls Engineering Project Title: Hirschkoff Addition
Engineer: AL 4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Project ID: 21230
Project Descr:
19
Printeo· 6 JAN 2022. 10:32AM
f Wood Beam Sottware copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 . ...
DESCRIPTION: FH-1
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set : ASCE 7-16
Material Properties
Analysis Method: Allowable Stress Design
Load Combination ASCE 7-16
Wood Species : Douglas Fir-Larch
Wood Grade : No.1
Beam Bracing : Completely Unbraced
Fb+
Fb -
Fc -Prll
Fe -Perp
Fv
Ft
6x10
Span = 10.50 ft
1,350.0 psi
1,350.0 psi
925.0psi
625.0psi
170.0 psi
675.0psi
E(1.565)
•
E : Modulus of Elasticity
Ebend-xx 1,600.0ksi
Eminbend -xx 580.0ksi
Density 31.210pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load : D = 0.020, L = 0.060 ksf, Tributary Width= 2.0 ft, (DECK)
Uniform Load : D = 0.0150 ksf, Tributary Width = 9.0 ft, (WALL)
Uniform Load : D = 0.020, L = 0.040 ksf, Tributary Width= 0.50 ft, (FLOOR)
Point Load : E = 1.565 k @ 7.0 ft, (HD STRAP)
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.704 1 Maximum Shear Stress Ratio
Section used for this span 6x10 Section used for this span
fb: Actual 1,499.65psi fv: Actual
Fb: Allowable = 2, 129.15psi Fv: Allowable
Load Combination +1.118D+2.10E Load Combination
Location of maximum on span 6.974ft Location of maximum on span
Span# where maximum occurs Span# 1 Span # where maximum occurs
Maximum Deflection Max Downward Transient Deflection 0.090 in Ratio= 1405 >=360
Max Upward Transient Deflection 0.000 in Ratio= 0 <360
Max Downward Total Deflection 0.179 in Ratio= 705>=240
Max Upward Total Deflection 0.000 in Ratio= 0<240
Overall Maximum Deflections
Load Combination Span Max.'-' Defl Location in Span Load Combination
+D+0.750L +0.5250E 1 0.1786 5.403
Vertical Reactions Support notation : Far left is #1
Load Combination Support 1 Support2
Overall MAXimum 1.856 2.130
Overall MINimum 0.522 1.043
DOnly 1.031 1031
+D+L 1.766 1.766
+D+0.750L 1.582 1.582
+0.60D 0.618 0.618
+D+0.70E 1.396 1.761
+D+0.750L+0.5250E 1.856 2.130
+0.60D+0.70E 0.984 1.349
L Only 0.735 0.735
E Only 0.522 1.043
Desi n OK
= 0.335 : 1
6x10
= 91 .15 psi
= 272.00 psi
+1.118D+2.10E
9.734ft
= Span# 1
Max.'+' Defl Location in Span
0.0000 0.000
Values in KIPS
Qualls Engineering Project Title: Hirschkoff Addition
Engineer: AL 4403 Manchester Ave #203
Encinitas, CA 92024
760-652-9257
Project ID: 21230
Project Descr: 20
Printed: 6 JAN 2022. 10:30AM
1Wood Beam L Software copyright ENERCAlC, INC. 1983-2020, Build:12.20.8.24
· t,I .; •
DESCRIPTION: FH-2
CODE REFERENCES
Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
Analysis Method : Allowable Stress Design
Load Combination ASCE 7-16
Wood Species : Douglas Fir-Larch
Wood Grade : No. 1
Beam Bracing : Completely Unbraced
Fb+
Fb-
Fc -Prll
Fe -Perp
Fv
Ft
1,350.0 psi
1,350.0 psi
925.0psi
625.0 psi
170.0 psi
675.0psi
. '
E : Modulus of Elasticity
Ebend-xx 1,600.0ksi
Eminbend -xx 580.0ksi
Density 31.210pcf
0(1.39) Lr(1.47)
6x10
Span = 6 .50 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load : D = 0.0150, Lr= 0.020 ksf, Tributary Width= 8.0 ft, (ROOF)
Uniform Load: D = 0.0150 ksf, Tributary Width = 9.0 ft, (WALL)
Uniform Load: D = 0.020, L = 0.040 ksf, Tributary Width = 7.0 ft, (FLOOR)
Point Load : D = 1.390, Lr = 1.470 k @ 5.50 ft, (RB-2)
DESIGN SUMMARY
Maximum Bending Stress Ratio
Section used for this span
fb: Actual
Fb: Allowable
Load Combination
Location of maximum on span
Span# where maximum occurs
Maximum Deflection Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Overall Maximum Deflections
Load Combination Span
+D+0.750Lr+0.750L 1
Vertical Reactions
Load Combination
Overall MAXimum
Overall MINimum
DOnly
+D+L
+D+Lr
+D..0.750Lr..0.750L
+D..0.750L
..0.60D
Lr Only
L Only
0.470 1
6x10
631.40psi
1,343.01 psi
+D+L
3.558ft
Span# 1
Maximum Shear Stress Ratio
Section used for this span
fv: Actual
Max."-" Defl
0.0650
0.021 in Ratio =
0.000 in Ratio=
0.065 in Ratio=
0.000 in Ratio=
Location in Span
3.369
Fv: Allowable
Load Combination
Location of maximum on span
Span# where maximum occurs
3754 >=360
0 <360
1199 >=240
0 <240
Load Combination
Support notation : Far left is #1
Support 1 Support 2
2.777 4.502
0.910 0.910
1.534 2.497
2.444 3.407
2.281 4.261
2.777 4.502
2.217 3.179
0.921 1.498
0.746 1.764
0.910 0.910
Desi n OK
0.530 : 1
6x10
112.70 psi
212.50 psi
+D+0.750Lr+0.750L
5.717ft
Span# 1
Max. '+" Dell Location in Span
0.0000 0.000
Values in KIPS
Qualls Engineering
Structural Engineering Services Sheet: 21 -----Project: I Jirschkoff Addition Job #: _2_1_23_0 __ _
l~nginccr: _/\_I_, __________ _ Dare:
Lateral Analysis
Tributary Area (ft2)
Level Component Weight (psi) Tributary Tributary Weight IWeight
Length (ft) Height (ft) (lbs) (lbs)
Main Roof 15 2,090 31,350
Roof Roof Deck 20 160 3,200 50,795
Exterior Wall 15 200 9.5 28,500
I ntcrior Wall 7 60 9.5 3,990
Main Floor 20 1,830 36,600
2nd Floor Deck 20 70 1,400 73,715 Exterior Wall 15 200 12.0 36,000
I ntcrior Wall 7 35 12.0 2,940 ,-. 124,510
C, (ASD) W (lbs) V (lbs)
0.120 124,510 14,977
Level W, (kips) h, (ft) W ,h; (k-ft)
Wh k V. (lbs) Area (f.2) V, (psi)
I:(W,h.")
Roof 50.8 21.5 1,092 0.55 8 275 2,250 3.7
2nd Floor 73.7 12 885 0.45 6,702 1,900 3.5
,~. 1,977 ,-. 7.2
C, X T. k
0.02 21.5 0.75 0.20 1.0
Wind Check
Ps
12.8
North-South East-West
Level Height (ft) Diaphragm V, (psi) Depth (ft) Level Height (ft) Diaphragm V, (psi) Depth (ft)
Roof Peak 22.5 -Roof Peak 22.5 --
Roof 21.5 33 2.2 Roof 21.5 42 1.8
2nd Floor 12 28 4.9 2nd Floor 12 35 3.9
'"· 7.1 "· 5.7
Direction Governing Load
Norrh-South Sci~nUc I 7.2 psf
East-West Seismic I 7.2 psf
Qualls Engineering
Structural Engineering Services
Direction
North-South
Level
Roof
2nd Floor
Controlling
Load
Seismic
Vx(Psf)
3.7
3.5
North-South
Level
Roof
2nd Floor
Direction
East-West
Level
Roof
2nd Floor
East-West
Grid
Kl
K
Controlli
na Load
Seismic
Vx (psf)
3.7
3.5
Level Grid Wall 1
Roof 4 16
5 2
2nd Floor 4 6
5 15.25
Grid
4
5
4
5
Wall2
3.5
3
Sheet: ~2=2 __ _
Project: Hirschkoff Addition Job #: 21230
Engineer: AL -----------Date:
Lateral Design
V Direct V Directly V Offset V
Grid Trib Area (ft') Cumulative (lbs) Above (lbs) Above (lbs) (lbs)
J 243 892 --892
K1 275 1,011 --1,011
J 403 1,420 892 2,312
K 250 882 0 1,01 1 1,893
Wall Len th ft
Wall 1 Wall 2 Total Minimum V I h:2w SWT e
10 10 10 89 1.00 6E
5.5 5.5 5.5 184 1.00 6E
5.5 5.5 5.5 420 1.00 3E
1.5 1.5 3 1.5 631 3.67 SSW18x11
V V Offset V Trib Area V Direct Directly Above Cumulativ (ft2) (lbs) Above
Clbs\ (lbs) e (lbs)
205 754 --754
275 1,011 --1,011
250 882 754 1,636
365 1,288 1,011 2,299
Wall Length (ft)
Wall 3 Total Minimum V (plf) h:2w SW Type
16 16 47 1.00 6E
5.5 2 184 1.00 6E
6 6 273 1.00 4E
6 24.25 3 95 1.00 6E
Q ualls Engineering
Structural Engineering Services Project: Hirschkoff Addition
Sheet: 23 ~~---
Job#: 21230
Engineer: _._-\_L _________ _ Date:
Overturning
Lw Add'IMot Mot RoofTrib Floor Ext Wall Int Wall Add'I Mres North-South min V (plf) (ft-lbs) (ft-lbs) (ft) Trib (ft) (ft) (ft) Mres (ft-lbs) (ft) (ft-lbs)
Roof J 10 89 7,580 1.33 8.5 3,973
Kl 5.5 184 8,596 1.33 8.5 1,202
2nd Floor J 5.5 420 25,428 1.33 11 1,466
K 1.5 587 9,685 1.33 11 109
North-South C (lbs) T (lbs) HD Capacity (lbs) DCR
Roof T 758 447 None 600 0.75
K1 1 563 1,392 MSTC40 1 920 0.73
2nd Floor 1 4,623 4.415 II DU4 4 565 0.97
K 6,942 6 885 SSWAB-1" 17.100 0.40
Lw Add'lMot Mot Roof Trib Floor Ext Wall Int Wall Add'l Mres East-West min V (plf) (ft-lbs) (ft-lbs) (ft) Trib (ft) (ft) (ft) Mres (ft-lbs) (ft) (ft-lbs)
Roof 4 16 47 6,408 7 8.5 29,760
5 13 184 20,319 8 8.5 20,914
2nd Floor 4 6 273 6,408 24,402 7 7.00 19.5 9,675
5 36 95 20,319 57,859 8 8.00 19.5 370,980
East-West C (lbs) T (lbs) HD Capacity DCR (lbs)
Roof 4 401 0 None 600 0.00
5 1,563 305 None 600 0.51
2nd Floor 4 4,067 2,806 HDU2 3,075 0.91
5 1,607 0 None 600 0.00
Qualls Engineering
Structural Engineering Services Project: Hirschkoff Addition
Sheer: _2_4 __ _
Job #: 21230
Engineer: ._\=L.,__ ________ _ Date:
FOUNDATION DESIGN
Allowable Soils Bearing Capacity
ew/Existing Foundation design
2,000 psf
b = 15
d = 18
15
18
2 #4
inch wide x
inch deep footing with
top and bottom _:J
1::======
Allowable Max Line Load
W ma., = b X ASBP
Allowable Max Point Load
P max = b X 2d X ASBP
Spread Footing Design
= 2,500 plf
= 7,500 lbs
Pmax = 62 X ASBP
F2= 2 foot square footing with 3 # 4 each way @ btm
pmax = 8,000 lbs
F2.5 = 2.5 foot square footing with 3 # 4 each way @ btm
Pma., = 12,500 lbs
F3 = 3 foot square footing with 4 # 4 each way @ btm
pmax = 18,000 lbs
F3.5 = 3.5 foot square footing with 4 # 5 each way @ btm
pmox = 24,500 lbs
F4 = 4 foot square footing with 5 # 5 each way @ btm
pmax = 32,000 lbs
FS = 5 foot square footing with 6 # 5 each way@ btm
Pmax = 50,000 lbs
MAX POINT LOADS:
(DB-2)R + (RB-2) = 8,360 + 2,870 = 11,230 => (N) F2.5 MIN.
(DB-3)R + (RB-3) = 6,400 + 2,720 = 9,120# => (E) SSW FTG O.K. BY INSPECTION
(D8-2)L + (DB-4)L = 3.036 + 2,120 = 5, 156# => (E) FTG O.K.
Qualls Engineering Sheet: _2~5 __ _
Structural Engineering Services Project: Hirschkoff Addition Job#: 21230
Date: Engineer: AL -=-==------------
GUARDRAIL ANCHOR DESIGN:
M ,IAX = 200# x 42" => 8,400"#
T MAX = 8,400"# / 2.5'' => 3,360#
T ,1.m•£R .,~c110 R = 3,360# / 4 SCREWS => 840# PER SCREW
T Al.Ll/<"DIA L,GSCREW = 225# x 5" => 1,125#
HSS2x2¼ POST
GUARDRAIL
PER ARCH'L
BEAH PER PLAN
r_J~
SECTION: A-A
(8) ¼" DIA. LAG SCREV'lS
(t," HIN. EHBED)
6.5" x 3.5" x ¼ THICK
STEEL PLATE
USE: 1/4" DL-\. L\.G SCREWS
w/ 5" EMBED
T,1.t = 1,125#
T,1.L > T ,,.,,
B.N. DECK SHT'G
DECK JOIST PER PLAN
V'l/ "LUS" HGR
Date: May 20, 2022
2121 Montie! Road, San Marcos CA 92069
760 839 1:302
>-t:
(.)
To: Joel Hirschkoff RECEIVED
Re:
2353 Jefferson Street
Carlsbad, CA 92008
E: joel.hirschkoff@ga.com
P: 858.229.1399
JUN O 9 2022
CITY OF CARLSBAD
BUILDING DIVISION
Proposed new residence located at 2353 Jefferson Street, Carlsbad, California
Subject: Updated Geotechnical Report
Ref:
1. Plans for the Hirschkoff Residence Addition, 2353 Jefferson Street, Carlsbad, California, 92008,
prepared by 3Points Design Build, dated 01-31-2022.
2. Limited Geotechnical Investigation and Evaluation, New Hirschkoff Residence to be located at
Jefferso n Street {APN 155-180-28), Carlsbad, California," EOG Project No. 135198-1, dated June
19, 2013.
3. Addendum No. 1 -Geotechnical Report, dated August 25, 2014, Proposed new Hirschkoff
Residence to be located at Jefferson Street, APN 155-180-28, Carlsbad, California.
4. Compaction Report, dated May 2, 2017, "Proposed residence, Jefferson Street (APN:155-180-
28), City of Carlsbad, prepared by Engineering Design Group.
1.0 SCOPE
We have provided the following limited geotechnical report for proposed second story addition to the
existing single-family residence at the above referenced address. This report references the original
geotechnical report and recommendations prepared by Engineering Design group, referenced above, for
the proposed existing residence
2.0 SITE AND PROJECT DESCRIPTION
As part of the preparation of this report, we visited the site to confirm the conditions in the area work
are similar to those at the time of the completion of original construction of the single-family residence.
The existing single-family residence consists of a split-level residence, three stories at the rear portion,
and one and two story elements at the front, south section. We understand the proposed scope of work
Hirschkoff Addition
2353 Jefferson Street, Carlsbad, California
ENGINEERING DESIGN GROUP
GEOTECHNICAL. CIVIL, STRUCTURAL CONSULTANTS
Page No. 1
Job No. 226778-1
includes a new second story addition to the western single-story garage.
3.0 FIELD INVESTIGATION
As the new additions are limited to second story additions over existing footprints, no additional field
investigation was performed as part of this update report.
4.0 SUBSURFACE CONDITIONS
Subsurface soil conditions outlined our original report included fill/weathered materials underlain by
sandstone material.
5.0 GROUND WATER
Static ground water was not encountered during the original investigation and in consideration that all
additions are second story additions, groundwater is not anticipated to be a significant concern to the
project provided the recommendations of this report are followed.
6.0 PRELIMINARY CONCLUSIONS AND RECOMMENDATIONS
In general, it is our opinion that the new structures and improvements, as discussed and described herein,
are feasible from a geotechnical standpoint, provided the recommendations of this report and all
applicable codes are followed.
• No grading, retaining walls, concrete slabs-on-grade floors, pools or infiltration treatment BMPs
are proposed as part of the proposed addition. Where these design elements are added, it
should be brought to the attention of Engineering Design Group for additional
recommendations.
• Based upon our review of the project foundation sheets, we understand new foundations are
limited to a new footing at the front of the garage.
7.0 SEISMIC DESIGN PARAMETERS
7.1 Seismic Design Parameters, as outlined in the table below.
Hirschkoff Addition
2353 Jefferson Street, Carlsbad, California
ENGINEERING DESIGN GROUP
GEOTECHNICAL, Clvtl, STRUCTURAL CONSULTANTS
Page No. 2
Job No. 226778-1
Site Class D
Seismic Design Category D
ASCE 7-16 Seismic Design Parameters
Ss (g) 1.052
S1 (g) 0.382
SMs (g) 1.263
Sos (g) 0.842
ASCE 7-16 Acceleration Parameters
PGA = MCEG peak ground acceleration 0.463
PGAM = Site modified peak ground acceleration 0.555
8.0 SHALLOW FOUNDATIONS
Based upon our review of past reports we anticipate the new foundation associated with the proposed
foundations will extend into competent material, recompacted during original site construction. The
following design parameters may be utilized for new foundations founded on competent paralic material.
8.1 Footings bearing uniformly in competent material may be designed utilizing maximum allowable
soils pressure of 2,000 psf.
8.2 Bearing values may be increased by 33% when considering wind, seismic, or other short
duration loadings.
8.3 The parameters in the table below should be used as a minimum for designing new footing width
and depth below lowest adjacent grade into competent paralic material. Footing depths are to be
confirmed in the field by a representative of Engineering Design Group prior to the placement of
form boards, steel and removal of excavation equipment.
No. of Floors Minimum Footing Width *Minimum Footing Depth Below
Supported
1
Hirschkoff Addition
2353 Jefferson Street, Carlsbad, California
Lowest Adjacent Grade
lSinches 18inches
ENGINEERING DESIGN GROUP
GEOTECHNICAL, CIVIL, STRUCTURAL CONSULTANTS
Page No. 3
Job No. 226778-1
No. of Floors Minimum Footing Width *Minimum Footing Depth Below
Supported Lowest Adjacent Grade
2 15inches 18inches
*Footings are anticipated to be founded in competent recompacted or paralic material.
8.4 All footings founded into competent material should be reinforced with a minimum of two #4
bars at the top and two #4 bars at the bottom (3 inches above the ground). For footings over 30
inches in depth, additional reinforcement, and possibly a stemwall system will be necessary, and
should be reviewed by project structural engineer prior to construction.
8.5 All isolated spread footings should be designed utilizing the above given bearing va lues and
footing depths and be reinforced with a minimum of #4 bars at 12 inches o.c. in each direction (3
inches above the ground). Isolated spread footings should have a minimum width and depth of
24 inches.
8.6 For footings adjacent to slopes a minimum of 10 feet horizontal setback in competent material or
properly compacted fill should be maintained. A setback measurement should be taken at the
horizontal distance from the bottom of the footing to slope daylight. Where this condition cannot
be met, it should be brought to the attention of the Engineering Design Group for review.
8.7 All excavations should be performed in general accordance with the contents of this report,
applicable codes, OSHA requirements and applicable city and/or county standards.
8.8 All foundation subgrade soils and footings shall be pre-moistened to 2% over optimum to a
minimum of 18 inches in depth prior to the pouring of concrete.
9.0 CONSTRUCTION OBSERVATION AND TESTING
The recommendations provided in this updated report are based on subsurface conditions disclosed by
the original investigation and our general experience in the project area. Interpolated subsurface
conditions should be verified in the field during construction. The following items shall be conducted
prior/during construction by a representative of Engineering Design Group in order to verify compliance
with the geotechnical and civil engineering recommendations provided herein, as applicable. The project
structural and geotechnical engineers may upgrade any condition as deemed necessary during the
development of the proposed improvement(s).
Hirschkoff Addition
2353 Jefferson Street, Carlsbad, California
ENGINEERING DESIGN GROUP
GEOTECHNICAL. CIVIL, STRUCTURAL CONSULTANTS
Page No. 4
Job No. 226778-1
9.9 Observation of footing excavations prior to steel placement and removal of excavation
equipment.
9.10 Testing of any fill placed, including retaining wall backfill and utility trenches.
9.11 Field observation of any "field change" condition involving soils.
9.12 Walk through of final drainage detailing prior to final approval.
The project soils engineer may at their discretion deepen footings or locally recommend additional steel
reinforcement to upgrade any condition as deemed necessary during site observations. Engineering
Design Group shall, prior to the issuance of the certificate of occupancy, issue in writing that the above
inspections have been conducted by a representative of their firm, and the design considerations of the
project soils report have been met. The field inspection protocol specified herein is considered the
minimum necessary for Engineering Design Group to have exercised due diligence in the soils engineering
design aspect of this building. Engineering Design Group assumes no liability for structures constructed
utilizing this report not meeting this protocol.
Before commencement of grading the Engineering Design Group will require a separate contract for
quality control observation and testing. Engineering Design Group requires a minimum of 48 hours' notice
to mobilize onsite for field observation and testing.
10.0 MISCELLANEOUS
It must be noted that no structure or slab should be expected to remain totally free of cracks and minor
signs of cosmetic distress. The flexible nature of wood and steel structures allows them to respond to
movements resulting from minor unavoidable settlement of fill or natural soils, the swelling of clay soils,
or the motions induced from seismic activity. All the above can induce movement that frequently results
in cosmetic cracking of brittle wall surfaces, such as stucco or interior plaster or interior brittle slab
finishes.
Data for this report was derived from surface and subsurface observations at the site and knowledge of
local conditions. The recommendations in this report are based on our experience in conjunction with the
limited soi ls exposed at this site. We believe that this information gives an acceptable degree of reliability
for anticipating the behavior of the proposed improvement; however, our recommendations are
professional opinions and cannot control nature, nor can they assure the soils profiles beneath or adjacent
to those observed. Therefore, no warranties of the accuracy of these recommendations, beyond the limits
of the obtained data, is herein expressed or implied. This report is based on the investigation at the
Hirschkoff Addition
2353 Jefferson Street, Carlsbad, California
ENGINEERING DESIGN GROUP
GEOTtCHNICAL CML STRUCTURAL CONSULTANTS
Page No. 5
Job No. 226778• l
described site and on the specific anticipated construction as stated herein. If either of these conditions
is changed, the results would also most likely change. Man-made or natural changes in the conditions of
a property can occur over a period. In addition, changes in requirements due to state-of-the-art
knowledge and/or legislation are rapidly occurring. As a result, the findings of this report may become
invalid due to these changes. Therefore, this report for the specific site, is subject to review and not
considered valid after a period of one year, or if conditions as stated above are altered.
It is the responsibility of the owner or his/her representative to ensure that the information in this report
be incorporated into the plans and/or specifications and construction of the project. It is advisable that a
contractor familiar with construction details typically used to deal with the local subsoil and seismic
conditions be retained to build the structure. If you have any questions regarding this report, or if we can
be of further service, please do not hesitate to contact us. We hope the report provides you with necessary
information to continue with the development of the project .
If you have any questions regarding the following report, please do not hesitate to contact our office.
Sincerely,
ENGINEERING DESIGN GROUP
Steven Norris
California GE 2590
Hirschkoff Addition
2353 Jefferson Street, Carlsbad, California
Erin E. Rist
California RCE 65122
ENGINEERING DESIGN GROUP
GEOTtCHNICAL. CIVIL, STRUCTURAL CONSULTANTS
Page No. 6
Job No. 226778·1
CBR2022-1071
2353 JEFFERSON ST
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Hirschkoff Residence
2353 Jefferson St
Carlsbad , Ca 92008
Project Designer:
3 Points Design Build
1506 West 10th Street
San Pedro, Ca 90732
281-684-4871
Report Prepared by:
Brian Hansen
Technical Energy
4336 Goldfinch St
San Diego, Ca 92103
858-472-2680
Job Number:
22-52
1te:
2022
> 1---0
HIRSCH KOFF: 345 SF ADDITION (TO ADD 1 BED, 1 FULL
BATH)// 67 SF BALCONY ,s summarized in this compliance report. This program has approval and is
!Sidential and Nonresidential 2019 Building Energy Efficiency Standards.
1551802800
3/30/2022
CBR2022-1071
oft Software -www.energysoft.com.
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 11
Form MF-1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
CERTIFICATE OF COMPLIANCE
Project Name: Hirschkoff Residence
Calculation Description: Title 24 Analysis
GENERAL INFORMATION
01 Project Name
02 Run Title
03 Project Location
04 City
06 Zip code
Hirschkoff Residence
ntle 24 Analysis
2353 Jefferson St
Carlsbad
92008
08 Climate lone 7
10 Building Type Single family
12 Project Scope AdditionOnly
14 Addition Cond. Floor Area (ft2) 345
16 Existing Cond. Floor Area (ft2) 3015
18 Total Cond. Floor Area (ft2) 3360
20 ADU Bedroom Count n/a
22 Is Natural Gas Available? Yes
Addition Alone Project Analysis Parameters
01 02
Existing Area (excl. new addition) (ftZ) Addition Area (exd. existing) (ft2)
3015 345
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
Calculation Date/Time: 2022-0l-31T0S:24:28-08:00
Input File Name: 22-52 HirschkoffAdd.ribd19x
OS Standards Version 2019
07 Software Version EnergyPro 8.3
09 Front Orientation (deg/ Cardinal) 115
11 Number of Dwelling Units 1
13 Number of Bedrooms 4
15 Number of Stories 1
17 Fenestration Average U-factor 0.35
19 Glazing Percentage (%) 40.87%
21 ADU Conditioned Floor Area n/a
03 04 OS
Total Area (ftZ) Existing Bedrooms Addition Bedrooms
3360 3 1
CF1R-PRF-01E
(Page 1 of 8}
06
Total Bedrooms
4
oz This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
Registration Number: 422-P010019749A-OOO-O0O-O00000O-0000 Registration Date/Time: 02/10/2022 21:50 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Effidency Rating System Services, Inc. (CHEERS) using Information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the Information contained In this document.
• CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-01-31 05:24:48
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Hirschkoff Residence
Calculation Description: Title 24 Analysis
Energy Use (kTDV/ft2-yr)
Space Heating
Space Cooling
IAQ Ventilation
Water Heating
Self Utilization/Flexibility Credit
Compliance Energy Total
1REQUIRED SPECIAL FEATURES
I Standard Design
0.69
22.74
0
50.4
n/a
73.83
Calculation Date/Time: 2022-01-31T0S:24:28-08:00
Input File Name: 22-52 HirschkoffAdd.ribd19x
ENERGY USE SUMMARY
I Proposed Design I Compliance Margin
1.63 -0.94
21.1 1.64
0 0
50.4 0
0 0
73.13 0.7
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
I
CFlR-PRF-OlE
(Page 2 of 8)
Percent Improvement
-136.2
7.2
0
n/a
0.9
The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building-level Verifications:
• --None -
Cooling System Verifications:
• --None --
Heating System Verifications:
• Verified heat pump rated heating capacity
HVAC Distribution System Verifications: . --None --
Domestic Hot Water System Verifications:
• -None -
ZONE INFORMATION
01 02 03 04 OS 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2
Add Conditioned (n) VCHPl 345 10 DHWSys 1 N/A
Registration Number: 422-P010019749A-00O-OOO--OOO000O-0000 Registration Date/Time: 02/10/2022 21:50 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Effld ency Rating System Servicesfslnc. (CHEERS) using information uploaded by third parties not affll/ated with or related to CHEERS. Therefore, CHEERS Is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained In th document.
-CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-01-31 05:24:48
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Hirschkoff Residence
Calculation Description: Title 24 Analysis
OPAQUE SURFACES
01 02 03
Name Zone Construction
(n) Front +25 Wall Add R-21 Wall
(n) Left +25 Wall Add R-21 Wall
(n) Back +25 Wall Add R-21 Wall
(n) Back +35 Wall Add R-21 Wall
(n) Right +25 Wall Add R-21 Wall
Raised Floor Add R-19 elevated
OPAQUE SURFACES -CATHEDRAL CEILINGS
01 02 03
04
Azimuth
140
230
320
330
so
n/a
04 05
OS
Orientation
n/a
n/a
n/a
n/a
n/a
n/a
Calculation Date/Time: 2022-01-31T0S:24:28-08:00
Input File Name: 22-52 HirschkoffAdd.ribd19x
06 07 08
Gross Area (ft2) Window and Door Tilt (deg) Area (ft2)
138 37.5 90
318 85.5 90
10 0 90
17 0 90
196 18 90
345 n/a n/a
06 07 08 09
09
Wall Exceptions
Extension
Extension
Extension
Extension
Extension
10
Name Zone Construction Azimuth Orientation Area (ft2) Skylight Area Roof Rise (x in Roof Roof Emittance (ft2) 12) Reflectance
Roof Add R-30 Roof 205 Left 210 0 3 0.1 0.85 Cathedral
Roof 2 Add R-30 Roof 205 Left 135 0 0 0.1 0.85 Cathedral
FENESTRATION / GLAZING
01 02 03 04 OS 06 07 08 09 10 11 12 13
Width Height Area U-factor SHGC
Name Type Surface Orientation Azimuth (ft) (ft) Mult. (ft2) U-factor Source SHGC Sourc
e
B/B/C Window (n) Front +25 Wall 140 3 4.5 1 13.5 0.33 NFRC 0.23 NFRC
Door2 Window (n) Front +25 Wall 140 3 8 1 24 0.33 NFRC 0.23 NFRC
D Window (n) Left +25 Wall 230 3 5 1 15 0.33 NFRC 0.23 NFRC
E Window (n) Left +25 Wall 230 5 5 1 25 0.33 NFRC 0.23 NFRC
F Window (n) Left +25 Wall 230 1 15 0.33 NFRC 0.23 NFRC
G Window (n) Left +25 Wall 230 2 2 1 4 0.33 NFRC 0.23 NFRC
-
Registration Number: 422-P010019749A-O0O-00O--O00000O-O000 Registration Date/Time: 02/10/2022 21 :50 HERS Provider: CHEERS
CFlR-PRF-0l E
(Page 3 of 8)
10
Status
New
New
New
New
New
New
11
Cool Roof
No
No
14
Exterior
Shading
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
Bug Screen
NOTICE: This document has been generated by ConSol Home Energy Efficiency Rati"f} System Services, Inc. (CHEERS) using information uploaded by third partles not affiliated with or related to CHEERS. Therefore, CHEERS Is not
r11sponslble for, and cannot guarantee, the accuracy or completeness of the Information contained In this document.
-CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-01-31 05:24:48
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Hirschkoff Residence
Calculation Description: Title 24 Analysis
FENESTRATION / GLAZING
01 02
Name Type
H Window
J Window
C Window
C2 Window
A Window
A2 Window
A3 Window
OVERHANGS AND FINS
01 02
Window
Depth
B/8/C 4
Door 2 4
D 2
E 2
G 2
H 2
03 04
Surface Orientation
(n) Left +25 Wall
(n) Left +25 Wall
(n) Left +25 Wall
(n) Left +25 Wall
(n) Right +25 Wall
(n) Right +25 Wall
(n) Right +25 Wall
03 04 OS 06
Overhang
Right Dist Up Left Extent Extent Flap Ht.
0.1 4 4 0
0.1 4 4 0
0.1 2 2 0
0.1 2 2 0
0.1 2 2 0
0.1 2 2 0
Calculation Date/Time: 2022-01-31TOS:24:28-08:00
Input File Name: 22-52 HirschkoffAdd.ribd19x
OS 06 07 08 09 10 11 12 13
CF1R-PRF--01E
(Page 4 of 8)
14
Width Height Mult.
Area U-factor U-factor SHGC Exterior SHGC Sourc Azimuth (ft) (ft) (ft2) Source Shading e
230 2 5 1 10 0.33 NFRC 0.23 NFRC Bug Screen
230 1 7.5 0.33 NFRC 0.23 NFRC Bug Screen
230 1 4.5 0.33 NFRC 0.23 NFRC Bug Screen
230 1 4.5 0.33 NFRC 0.23 NFRC Bug Screen
50 1 6 0.5 NFRC 0.23 NFRC Bug Screen
50 1 6 0.5 NFRC 0.23 NFRC Bug Screen
50 1 6 0.5 NFRC 0.23 NFRC Bug Screen
07 08 09 10 11 12 13 14
Left Fin Right Fin
Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up
0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
Registration Number: 422-P01001 9749A-000..()00-0000000-0000 Registration Date/Time: 02/10/2022 21:50 HERS Provider: CHEERS
NOTICE: This document has been generated by Consol Home Eneryy Efficiency Ratin9 System Services, Inc. (CHEERS) using information uploaded by third paroes not affiliated with or related to CHEERS. Therefore, CHEERS is not
,:esponslble for, and cannot guarantee, the accuracy or completeness of the Information contained In this document.
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-01-31 05:24:48
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Hirschkoff Residence
Calculation Description: Title 24 Analysis
OPAQUE SURFACE CONSTRUCTIONS
01 02
Construction Name Surface Type
R-21 Wall Exterior Walls
R-30 Roof Cathedral Cathedral Ceilings
R-19 elevated Exterior Floors
BUILDING ENVELOPE -HERS VERIFICATION
01
Quality Insulation Installation (QII)
Not Required
WATER HEATING SYSTEMS
01 02
Name System Type
DHWSys 1 Domestic Hot Water
(DHW)
03
Construction Type
Wood Framed Wall
Wood Framed
Ceiling
Wood Framed Floor
02
Calculation Date/Time: 2022-01-31T0S:24:28-08:00
Input File Name: 22-52 HirschkoffAdd.ribd19x
04 OS 06 07
Total Cavity Interior/ Exterior
Framing Continuous U-factor R-value R-value
2x6 @ 16 in. 0. C. R-21 None I None 0.069
2x10 @ 24 in. 0. C. R-30 None I None 0.035
2x12 @ 16 in. 0. C. R-19 None I None 0.046
,.
03
08
CF1R-PRF-01E
(Page 5 of 8)
Assembly Layers
Inside Finish: Gypsum Board
Cavity/ Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
Roofing: Light Roof (Asphalt Shingle)
Roof Deck: Wood
Siding/sheathing/decking
Cavity/ Frame: R-30 / 2x10
Inside Finish: Gypsum Board
Floor Surface: Carpeted
Floor Deck: Wood
Siding/sheathing/decking
Cavity/ Frame: R-19 / 2x12
04
High R-value Spray Foam Insulation Building Envelope Air Leakage CFMS0
Not Required Not Required n/a
03 04 05 06 07
Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification
Standard Distribution DHW Heater 1 (1) n/a None n/a System
Registration Number: 422-P010019749A-O0O-O0O-O00000O-OO00 Registration Date/Time: 02/10/2022 21:50 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Enerr;y Effldency RiJting System Services, Inc. (CHEERS) using Information uploaded by third parties not affillated with or related to CHEERS. Therefore, CHEERS Is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained In this document.
• CA Building Energy Efficiency Standards-2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-01-31 05:24:48
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Hirschkoff Residence
Calculation Description: Title 24 Analysis
WATER HEATERS
01 02 03
Heating
Name Element Tank Type
Type
DHW Gas Consumer
Heater 1 Instantaneous
WATER HEATING -HERS VERIFICATION
01 02
Name Pipe Insulation
DHW Sys 1 -1/1 Not Required
SPACE CONDITIONING SYSTEMS
01
04 OS 06
Tank Energy #of
Units Vol. Factor or
(gal) Efficiency
1 0 0.81-UEF
03
Parallel Piping
Not Required
02 03
07 08
Tank
Calculation Date/Time: 2022-01-31TOS:24:28-08:00
Input File Name: 22-52 HirschkoffAdd.ribd19x
09 10 11 12
Standby 1st Hr. Tank Location Input Rating Insulation NEEA Heat Pump Loss or Rating or or Ambient or Pilot R-value Brand or Model
(Int/Ext) Recovery Eff Flow Rate Condition
<= 200 0 n/a n/a n/a n/a kBtu/hr
04 OS 06 07
Compact Distribution Compact Distribution Recirculation Control Central DHW
Type Distribution
Not Required None Not Required Not Required
04 OS 06 07 08 09
Required Verified
13
Status
Existing
CFlR-PRF-0lE
(Page 6 ofS)
14
Verified
Existing
Condition
n/a
08
Shower Drain Water
Heat Recovery
Not Required
10 11
Heating Cooling Heating Unit Cooling Unit Distribution Name System Type Fan Name Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count
(n) VCHPl Heat pump heating cooling Heat Pump Heat Pump n/a n/a Setback New NA 1 1 System 1 System 1
01 02 03 04 OS 06 07 08 09 10 11
HVAC -HEAT PUMPS
Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification
HSPF/COP Cap47 Cap 17 SEER EER/CEER
Heat Pump System 1 Ductless 1 8.2 10000 6600 14 9.5 Not Zonal Single Heat Pump System
MiniSplit HP Speed 1-hers-htpump
Registration Number: 422-P010019749A-000-000-0000000-0000 Registration Date/Time: 02/10/2022 21 :50 HERS Provider: CHEERS
NOTICE: This document has been generated by Consol Home Energy Efficiency Ratin9 System Services, Inc. (CHEERS) using Information uploaded by third parties not afflflated with or related to CHEERS. Therefore, CHEERS is not
responsible for, and cannot guarantee, the accuracy or completeness of the Information contained In this document.
• CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-01-31 05:24:48
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Hirschkoff Residence
Calculation Description: Title 24 Analysis
HVAC HEAT PUMPS -HERS VERIFICATION
01 02
Name Verified Airflow
Heat Pump System Not Required 1-hers-htpump
03 04
Airflow Target Verified EER
0 Not Required
Calculation Date/Time: 2022-0l-31T0S:24:28-08:00
Input File Name: 22-52 HirschkoffAdd.ribd19x
OS 06 07 08
Verified SEER Verified Refrigerant Verified HSPF Verified Heating
Charge cap47
Not Required No No Yes
CF1R-PRF-01E
{Page 7 of 8)
09
Verified Heating
Cap17
Yes
Registration Number: 422-P010019749A--OOO-OOO-OOOO0OO-OOOO Registration Date/Time: 02/10/2022 21:50 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Effldency Ratil1!J System Services, Inc. (CHEERS) using Information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS Is not ,:,esponslble for, and cannot guarantee, the accuracy or completeness of the lnformat;on contained in this document.
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-01-31 05:24:48
Schema Version: rev 20200901
CERTIFICATE OF COMPLIANCE
Project Name: Hirschkoff Residence
Calculation Description: Title 24 Analysis
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Brian Hansen
Company:
Technical Energy Calculations
Address:
4336 Goldfinch Street
City/State/Zip:
San Diego, CA 92103
RESPONSIBLE PERSON'S DECLARATION STATEMENT
i certify the following under penalty of perjury, under the laws of the State of California:
Calculation Date/Time: 2022-01-31T05:24:28-08:00
Input File Name: 22-52 HirschkoffAdd.ribd19x
Documentation Author Signature:
'BvUuvtl~
Signature Date:
02/10/2022
CEA/ HERS Certification Identification (if applicable):
R19-14-30046
Phone:
858-472-2680
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
CF1R-PRF-01E
(Page 8 of 8)
cABEC
C.-AJ>odouonof Comulunt> llilili·· --
2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of ntle 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name: Responsible Designer Signature:
Jason Molgren J Ct1,0-V\I M o-lg,r-e-rv
Company: Date Signed:
3-Points Design+Build ,,, 02/10/2022
Address: License:
1506 W 10th St 1038294
City/State/Zip: Phone:
San Pedro, CA 90732 3105135453
Digitallr s/Qned by ConSol Home Energy Effldency Rating System Services, Inc. (CHEERS). This digital signature Is provided In order to secure the conten orthls registered document, and In no way lmpfies Registration Provider responsibfllty for the accuracy of the Information.
Registration Number: 422-P010019749A-000-000-0000000-0000 Registration Date/Time: 02/10/2022 21:50 HERS Provider: CHEERS
NOTICE: This document has been generated by ConSol Home Energy Efflclency Ratlf19 System Services/ Inc. (CHEERS) using Information uploaded by third parties not afflffated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the Information contained in th s document.
• CA Building Energy Efficiency Standards• 2019 Residential Compliance Report Version: 2019.2.000 Report Generated: 2022-01-31 05:24:48
Schema Version: rev 20200901
RESIDENTIAL MEASURES SUMMARY RMS-1
Project Name Building Type @ Single Family lil Addition Alone I Date
Hirschkoff Residence D Multi Family D Existing+ Addition/Alteration 2111/2022
Project Address California Energy Climate Zone I Total Cond. Floor Area I Addition I # of ~nits
2353 Jefferson St Carlsbad CA Climate Zone 07 345 345
INSULATION Area
Construction Type Cavity (tr) Special Features Status
Wall Wood Framed R20 101 New
Wall Wood Framed R20 233 New
Wall Wood Framed R20 10 New
Wall Wood Framed R20 17 New
Wall Wood Framed R20 178 New
Roof Wood Framed Rafter R30 345 New
Floor Wood Framed wlo Crawl Space R 19 345 New
FENESTRATION I Total Area: 1411 Glazina Percentaae: 40.9% I New/Altered Averaae U-Factor: 0.35
Orientation Area(tr) U-Fac SHGC Overhang Sidefins Exterior Shades Status
Front (SE) 37.5 0.330 0.23 4.0 none NIA New
Left (SW) 54.0 0.330 0.23 2.0 none NIA New
Left (SW) 31.5 0.330 0.23 none none NIA New
Right (NE) 18.0 0.500 0.23 none none NIA New
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Split Heat Pump 8.20HSPF Split Heat Pump 14.0SEER Setback New
HVAC DISTRIBUTION Duct
Location Heatina Cooling Duct Location R-Value Status
(n) VCHP Ductless I with Fan Ductless nla nla New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
EneravPro 8.3 bv EneravSoft User Number: 1082 ID: 22-52 Paae 11 of16
2019 Low-Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. •Exceptions may apply.
(01/2020)
Building Envelope Measures:
§ 110.6(a)1:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less
when tested oer NFRC-400 ASTM E283 or AAMAJWDMA/CSA 101/I.S.2/A440-2011:
§ 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of§ 10-111 (a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables
110.6-A, 110.6-8, or JA4.5 for exterior doors. Thev must be caulked and/or weather-strinM<l.'
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
casketed, or weather strinood.
§ 110.8(a): Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods
and Services IBHGS).
§ 110.8(9): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of§ 110.8(9).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the reauirements of§ 110.8(i) and be labeled oer 610-113 when the installation of a cool roof is Srv:>t'ified on the CF1 R.
§ 110.80): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood-frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in§ 110.7, including but not limited
to olacina insulation either above or below the roof deck or on too af a drywall ceiling.'
§ 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall ar have a U-factor af 0.102 or less, ar R-20 in 2x6 inch wood framing or
§ 150.0(c): have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls
must meet Tables 150.1-A ors:
§ 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor:
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
§ 150.0(Q: facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and
UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of§ 110.8(9).
§ 150.0(g)1:
Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor
retarder. This reauirement also aoolies to controlled ventilation crawl soace for buildinas comolvina with the exceotion to§ 150.0(dl.
§ 150.0(g)2:
Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air-nermeable insulation.
§ 150.0(q):
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weiahted averaae U-factor of all fenestration must not exceed 0.58:
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces.
§ 150.0(e)1: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)2:
Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is eouinn<>rl with a readily accessible operable, and tiaht-frttina damner or combustion-air control device:
§ 150.0(e)3: Flue Damper. Masonry ar factory-built fireplaces must have a flue damper with a readily accessible control.'
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
aooliances must be certified bv the manufacturer ta the California Enemv Commission:
§ 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiencv requirements in Table 110.2-A throuah Table 110.2-K:
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for
comnression heatino is hiaher than the cut-off temoorature for sunnlementarv heatina. •
§ 110.2(c):
Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat:
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)4: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of
§ 110.3(c\4.
§ 110.3(c)6:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose
bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed.
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except
§ 110.5: appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour); and pool and spa heaters.
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook,
§ 150.0(h)1: Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards
Manual; or the ACCA Manual J using design conditions specified in§ 150.0(h)2.
I
2019 Low-Rise Residential Mandatory Measures Summary
§ 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer
§ 150.0(h)3B:
Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water-heating systems, must have
a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must
be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum
§ 150.00)2A: insulation wall thickness of one inch or a minimum insulation R-value of 7.7: the first five feet of cold water pipes from the storage tank; all hot
water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch; all hot water piping with a nominal diameter less
than 3/4 inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks,
buried below grade, and from the heating source to kitchen fixtures:
Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(j)3: wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes).
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a
Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve.
Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of
the following: A dedicated 125 volt, 20 amp electrical receptacle connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG
copper branch circuit, within three feet of the water heater without obstruction. Both ends of the unused conductor must be labeled with the
§ 150.0(n)1 : word 'spare' and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker
for the branch circuit and labeled with the words 'Future 240V Use'; a Category Ill or IV vent, or a Type B vent with straight pipe between the
outside termination and the space where the water heater is installed; a condensate drain that is no more than two inches higher than the base
of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu per hour.
§ 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of§ 110.3(c)5.
Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification
§ 150.0(n)3: Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing
agency that is approved by the Executive Director.
Ducts and Fans Measures:
Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
§ 110.8(d)3: contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compllance. All air-distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0
and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and
plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned
space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and
surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must be
§ 150.0(m)1: mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable requirements of UL
181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than¼
inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums
designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air.
Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause
reductions in the cross-sectional area.·
Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure-sensitive tapes,
§ 150.0(m)3: mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)?: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers.
§ 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed
§ 150.0(m)9: to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular
foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation.
§ 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non-porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with§ 150.0(m)11 and Reference Residential Appendix RA3.
Air Flltratlon. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or
§ 150.0(m)12: equivalent filters. Fillers for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure
drops and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service:
Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole
for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be~ 350 CFM
§ 150.0(m)13: per ton of nominal cooling capacity, and an air-handling unit fan efficacy s 0.45 watts per CFM for gas furnace air handlers ands 0.58 watts per
CFM for all others. Small duct high velocity systems must provide an airflow~ 250 CFM per ton of nominal cooling capacity, and an air-handling
unit fan efficacy s 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3:
2019 Low-Rise Residential Mandatory Measures Summary
Requirements for Ventilation and Indoor Air Quality:
§ 150.0(o)1 : Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation
and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in§ 150.0(o)1.
Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with
§ 150.0(o)1C: other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates
determined by ASHRAE 62.2 Sections 4.1.1 and 4.1 .2 and as specified in§ 150.0(o)1C.
Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in
§ 150.0(o)1E: accordance with Equation 150.0-B and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced
system is not used, all units in the building must use the same system type and the dwelling-unit envelope leakage must be s 0.3 CFM at 50 Pa
(0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8.
Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide
§ 150.0(o)1F: ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150.0-B. All unit airflows must be
within 20 oercent of the unit with the lowest airflow rate as it relates to the individual unit's minimum reauired airflow rate needed for compliance.
§ 150.0(o)1G: Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2.
Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential
§ 150.0(o)2: Appendix RA3.7. A kitchen range hood must be verified in accordance with Reference Residential Appendix RA3.7.4.3 to confirm It is
rated by HVI to comply with the airflow rates and sound reauirements as snecified in Section 5 and 7.2 of ASHRAE 62.2.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a): that complies with the Appliance Efficiency Regulations; an on-Off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance healina:
§ 110.4(b)1 : Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or
dedicated suction and return lines, or built-in or built-up connections to allow for future solar heatina.
§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3: Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or proarammed to run only durina off-peak electric demand periods.
§ 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
§ 150.0(p): Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
§ 110.9: of§ 110.9.'
§ 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
§ 150.0(k)1 C: Recessed Down light Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
labeling; air leakage; sealing; maintenance; and socket and light source as described in§ 150.0(k)1C.
§ 150.0(k)1D: Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an
output freauency no less than 20 kHz.
§ 150.0(k)1 E: Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be
controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens.
§ 150.0(k)1F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the aoolicable reauirements of§ 150.0(kl.'
§ 150.0(k)1G: Screw based luminaires. Screw based lumlnaires must contain lamps that comply with Reference Joint Appendix JA8. •
§ 150.0(k)1H: Light Sources in Enclosed or Recessed Luminalres. Lamps and other separable light sources that are not compliant with the JA8 elevated
temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires.
Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to
§ 150.0(k)11: comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no
more than 150 lumens, and are equipped with controls that automatically tum the lighting off when the drawer, cabinet or linen closet is closed.
§ 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7 A.
§ 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems.
§ 150.0(k)2C: Interior Switches and Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually
turned ON and OFF.*
§ 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E: Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to
comply with§ 150.0(kl.
§ 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of§ 110.9.
. 2019 Low-Rise Residential Mandatory Measures Summary
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it:
§ 150.0(k)2G: provides functionality of the specified control according to§ 110.9; meets the Installation Certificate requirements of§ 130.4; meets the
EMCS reQuirements of§ 130.0(e); and meets all other requirements in§ 150.0(k)2.
§ 150.0(k)2H: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in§ 150.0(k) if it
provides the functionality of a dimmer accordina to & 110.9, and comolies with all other aoolicable reauirements in & 150.0(kl2.
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
§ 150.0(k)21: be controlled by an occupant sensor or a vacancy sensor providing automatic-off functionality. If an occupant sensor is installed, it must be
initially configured to manual-on operation using the manual control required under Section 150.0(k)2C.
§ 150.0(k)2J:
Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for
dimminQ, and that are not controlled by occuoancy or vacancy sensors, must have dimminQ controls.'
§ 150.0(k)2K: Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling-lnstalled lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A: buildings on the same lot, must meet the requirement in item§ 150.0(k)3Ai (ON and OFF switch) and the requirements in either
§ 150.0(k)3Aii (photocell and either a motion sensor or automatic time switch control) or§ 150.0(k)3Aiii (astronomical time clock), or an EMCS.
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances,
§ 150.0(k)3B: balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either§ 150.0(k)3A or
with the aoolicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots
§ 150.0(k)3C: or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by§ 150.0(k)3B or§ 150.0(k)3D must comply with
the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with§ 140.8; or must consume no more than 5 watts of
DOWQr as determined accordina to & 130.0(cl.
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
aoolicable reauirements for nonresidential aaraaes in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
buildinQ must be comply with Table 150.0-A and be controlled by an occuoant sensor.
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in
§ 150.0(k)6B: that building must:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with 10 or more single family residences and where the
§ 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which
do not have a ohotovoltaic svstem installed must comolY with the roouirements of & 110.10/blthrouah § 110.10(e).
§ 110.10(a)2: Low-rise Multifamily Buildings. Low-rise multi-family buildings that do not have a photovoltaic system installed must comply with the
requirements of§ 110.10(b) through§ 110.10(d).
Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access,
pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by
a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80
square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with
§ 110.10(b)1: roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building
and have a total area no less than 250 square feet. For low-rise multi-family buildings the solar zone must be located on the roof or overhang of
the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the
building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone
requirement is applicable to the entire building, including mixed occupancy.'
§ 110.10(b)2: Azimuth. All sections of the solar zone located on steep-sloped roofs must be oriented between 90 degrees and 300 degrees of true north.
§ 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted eauioment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest ooint of the solar zone, measured in the vertical Diane.'
§ 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof
dead load and roof live load must be clearty indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a
§ 110.10(c): pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family
residences and central water-heatin!l systems, a pathway reserved for routin!l plumbin!l from the solar zone to the water-heating system.
§ 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from§ 110.10(b) through
§ 110.10(c) must be provided to the occupant.
§ 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
§ 110.10(e)2: Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
breaker for a future solar electric installation. The reserved space must be permanently marked as 'For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name Date
Hirschkoff Residence 2/11/2022
System Name Floor Area
(n) VCHP 345
ENGINEERING CHECKS SYSTEM LOAD
Number of Svstems 1 COIL COOLING PEAK COIL HTG. PEAK
Heating System CFM Sensible Latent CFM Senslble
Output oer System 10,000 Total Room Loads 160 3,980 202 97 4,729
Total OutJ>ut (Btuh) 10,000 Return Vented Lighting 0
Output (Btuh/sqft) 29.0 Return Air Ducts 0 0
Cooling System Return Fan 0 0
Output oer System 9,000 Ventilation 0 0 0 0 0
Total OutJ>ut (Btuh) 9,000 Supply Fan 0 0
Total OutJ>ut (Tons) 0.8 Supply Air Ducts 0 0
Total Output (Btuh/sqft) 26.1
Total OutJ>ut (saft/Tonl 460.0 TOTAL SYSTEM LOAD 3,980 202 4,729
Air System
CFM oer System 350 HVAC EQUIPMENT SELECTION
Airflow (cfm) 350 Fujitsu AOU9RL2 6,895 1,943 7,650
Airflow (cfm/sqft) 1.01
Airflow (cfm/Ton) 466.7
Outside Air (%) 0.0% Total Adjusted System Output 6,895 1,943 7,650
Outside Air (cfm/sqft) 0.00 (Adjusted for Peak Design conditions)
Note: values above aiven at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM I Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS Airstream Temoeratures at Time of Heating Peak)
34°F 70°F 70 °F 115 °F
-• , I ~~ 1-1 I C ~ l Outside Air -o-0 cfm Supply Fan Heating Coil 115 °F .. 350 cfm II ROOM
70°F 70°F
-~J-1 I D ~ I --
COOLING SYSTEM PSYCHROMETRICS Airstream TemDAratures at Time of Coollna Peak)
83 / 68 °F 78 /62 °F 78 I 62 °F 55 / 54 °F
-• El ~~ I I I ~ ~ l Outside Air ~ I""
O cfm Supply Fan Cooling Coil 55 / 54 °F
' 350 cfm
ROOM ■I 41 .0%
78 / 62 °F 78 I 62 °F .. ~ 1-r r c-I
~ -