Loading...
HomeMy WebLinkAboutPS 2024-0013; GEMS OF LA COSTA; Sign Permits/Programs (PS) P-11 Page 1 of 4 Rev. 10/13 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov REVIEW FOR SIGN PERMIT P-11 PLANNING APPLICATION # REC'D BY DATE SIGN FEE SIGN PROGRAM FEE RECEIPT NO. All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. The application must be submitted prior to 4:00 p.m. Average processing time: 2 weeks Name of Project: Address of Project: Assessor Parcel Number: Related Planning Case Number(S): TYPE OF DEVELOPMENT: (a) Residential (d) Hotel/Motel (g) Theater (j) Produce Stand (b) Commercial (e) Service Station (h) Gov’t/Church/School (k) Nursery (c) Office/Industrial (f) Prof. Care (i) Public Park (l) P-U/OS Zone SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA Yes No Specific Plan Number VILLAGE REVIEW AREA (If yes, please complete information on page 3) Yes No SOUTH CARLSBAD COASTAL REVIEW AREA Yes No SIGN ORDINANCE: Yes No COASTAL ZONE: Yes No {'city of Carlsbad □ □ □ □ □ □ □ □ □ □ P-11 Page 2 of 4 Rev. 10/13 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes No Date PROPOSED PERMANENT SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Pole** Monument** Wall Suspended/Projecting Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: TYPE MAXIMUM NUMBER ALLOWED NUMBER PROPOSED MAXIMUM SIGN AREA PROPOSED SIGN AREA MAXIMUM SIGN HEIGHT PROPOSED SIGN HEIGHT Construction** For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right- of-way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. □ □ P-11 Page 3 of 4 Rev. 10/13 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: sq. ft. Total Building Street Frontage: linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: sq. ft. Total Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches I I I I P/L Sight Distance Requirement / I Show building/s : I ! I . : I : I . ,_ ---!-Show setbacks from all curbs --- ' ! ' I ' I : I Show all property lines I : P/L : I ! I curb line . ! ! -------- ---~-- - ' . Sight Visibility I Street Name(s) (i) I I North P-11 Page 4 of 4 Rev. 10/13 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) MAILING ADDRESS MAILING ADDRESS CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ™ In right-of-way ™ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: Date: P-37 Page 1 of 1 Rev. 2/2022 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov Certificate of Accuracy P-37 Project Name__________________________ Type of permit(s) applying for____________________________ CITY OF CARLSBAD - PLANNING DIVISION CERTIFICATE OF ACCURACY I certify all documents and plans clearly and accurately show all existing and all proposed buildings, structures, access roads, and utilities/utility easements. All proposed land use activities, improvements to land, and/or building modifications or additions are clearly labeled on the site plan of the approved plan set. I understand that any potentially existing detail within these plans inconsistent with the site plan are not approved and may be required to be altered or removed. The submitted documents and plans show the correct dimensions of the property, the buildings, and structures and their setbacks from property lines and from one another, access roads/easements, and utilities. The existing and proposed use of land and of each building as stated is true and correct. Further, all improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. All easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. Applicant: _______ Date: _____________ {'city of Carlsbad P-29 Page 1 of 2 07/11 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 3/11/2024 PROJECT NAME: GEMS OF LA COSTA APN: 215-050-7500 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 6985 EL CAMINO REAL UNIT 106 This plan check review is complete and has been APPROVED by the PLANNING Division. By: JUSTYN CHAMBERLAIN A Final Inspection by the PLANNING Division is required Yes No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to applicant’s email and are available online at: Carlsbad's Customer Self Service Portal For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 442-339-2610 ENGINEERING 442-339-2750 FIRE PREVENTION 442-339-2665 Justyn Chamberlain 442-339-5104 Justyn.Chamberlain@carlsbadca.gov «t ~ CITY OF CARLSBAD □ □ ~ ~ □ □ P-29 Page 2 of 2 07/11 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Comments: PLEASE REVISE PLANS TO CONFORM TO PAGE 7 OF THE “PLAZA PASEO REAL” SIGN PROGRAM (ATTACHED VIA EMAIL, PICTURED BELOW), WHERE THE PEG FOR A SIGN WITH A 4” RETURN NEEDS TO BE 1-3/8” … WHILE PROPOSED PEGGING ON YOUR PLANS IS 1-7/8”: «t ~ CITY OF CARLSBAD r-s• RETURNS +-+ AlUMINUMCHANNEl INSTAUWITH 3 llOSCREWS INlOPlASTICANCHORS 1/8 X ?" LAGS INTO EXPANSION SHIHDS TRIM-CAP ~~~~l:~::ACEWAY STANOARDGlASSSTANO TRANSrORMER ~ 4"RElURNS +<./ ,3/0"PIGOIFWAll 1/!I X 2" LAGS INTO EXPANSION SHIELDS ALUMINUM RACEWAY -OTO-IS WIRE ACRYLIC FACE OISCONNCCT SWITCH LEXANBACKUP TR:ANsrORM[R NCONlU8C -1r---tl!lc=-i!-..,!.,l)<---f--CONDUllW/GTOINSIDE CLEAIHEXANBACKS • • DISCONNECTSWITCH NEON TUBE -H(CTROBITS WEEPHOlES---'<--~' rACIA ---:-71 SECTION A p.,c HOUSING 3/4" COUOUIT THRU WAll WHPHOLES FACIA SECTION D SIGN TO BE UL APPS!OvtD AND BEAR UL lABEL LEXAN FACED CHANNEL LETTERS PK HOUSINGS REVERSE PAN CHANNELS THROUGH FACE AND HALO ILLUMINATION lUMlNUMCHANNEl IRIMCAP ::.~!~~~:~:,:<SION SHIElDS GT0-1S WIR[ STANDARD GLASS STANO 1RANSr0RM(R HAT CUTOUT OISCONNCCTSWITCH ALUMINUM OVERLAYS CONDUITW/GTOINSIOE NEONTU8£ P-kHOUSlNG fASCIA scruws INIOPIASIICANCHORS SECTION B SIGN TO II( Ut AJ'PROYt:0 .t.N0 lf.U Ul IAB{l EXPOSED MEON WITH ALUMINUM FACE OVERLAYS ~4"RCIURNS ✓ ✓l-318"PIGOlfWAII +f 1r:,~~~\:JH~~¾~;fui•J/2"SCREWS 1/11 X 2" LAGS INT'Ol>IPANSION SHIELDS ALUMINUM RACEWAY GJ0-1.5WIRE LEXANfAC(S TRANSFORMER CLEAR lEXAN BACKS DISCONNECT $WI I CH NCON TU8E -+--1>1111.l..lalF--+-nrcnoens 3/4"CONDUITJHRUWAll WHPHOlES FACIA ---::-,UC-- SECTION C SIGN 10 IE Ul APPltOYEO AHO MAit Ul LABH ~4"R£1\JRNS ✓/ 1-3/l"PCGOIFWMI ALUMINUMCHANNEL .:~~1N~~i~~~~~1M)~~l;~~1i'cWERI 1/8X2.LAGSINTOEXPANSIONSHIHDS ALUMINUMRAC(WAY llXANBACKUP GTO-lSWIRE 1/2"ClEARPlEXPUSHTHROUGH TRANSfORMCR CLEARLEUNIACKS -• • DISCONNCClSWITCH NEOUTUBE [lECTROBns 3/4.CONDUlllHRUWAll WCEPHOLlS FACIA SECTION E REVERSE PAN CHANNELS THROUGH FACE AND HALO ILLUMINATION PUSH THROUGH GRAPHICS PAINTED.071AIUM. SIGNR[lURN ACRYLIC SIGN rACC HUORESC£NTUGHT BAllASJ FURNISHED BYSIGN SHOP. PAINTED ALUM. FACIAi EXTRUSION RETURN SEALANTAlLSIOES ANCHOR 80lT/8RACKIT-SIZE IS SUBMIT TEO TO JURISDICTION fORAPPROVAl flUOlllSC(NTTUIINGMOUNl[D ONAlUM. WIRING TRACK(All ENCIOSCO WIRINGI Fl£)( CONDUIT SUPPUED IN LETTER. STU88EO THROUGH AND CAULKED BY SIGN INS TALLER 4"X 4" JUNCTION BOX SUPPLIED AND INSTALLED BY G.C. •s ELECTRICIAN. SUBMITTAL 3 FABRICATION DRAWINGS 02.2024 1 2/23/24 Plaza Paseo Real BY: Date: THIS APPROVAL IS FOR LANDLORD REVIEW ONLY AND IS NOT A PLAN CHECK REGARDING DIMENSIONAL ERROSRS, OMISSIONS, CODES OR ANY REQUIREMENTS OF GOVERNING AUTHORITIES. LANDLORD REQUIRES ALL PERMITS FROM GOVERNING AUTHORITIES TO BE SUBMITTED PRIOR TO COMMENCEMENT OF TENANT IMPROVEMENTS. CENTER: Not Approved Approved Vestar Property MGMT. Approved As Noted 1. All work to be coordinated with Vestar Property Manager. 2. No work to impede the daily operations of existing Tenants, work should be scheduled either before or after Center's Operation hours. 3. All penetrations into building need to be appropriately water proofed and sealed. 4. Installer insurance must be on file and approved prior to scheduling of work. 5. Tenant is responsible for patching and painting building where old sign was removed and new sign will not cover. Property Management will supply paint spec to match existing color or sample should be taken. 6. Tenant is responsible for patching and painting building where any penetrations or damage has occurred as a result of Tenant's sign installation or removal. 7. Prior to installation, sign permit must be obtained by authority having jurisdiction. PS2024-0013 JUSTYN CHAMBERLAIN 3/13/2024 JEWELERS COASTAL SiGNS CSLB #1075984 THE FOLLOWING DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, CONCEPTS AND ARRANGEMENTS CONTAINED HEREIN ARE AND SHALL REMAIN THE PROPERTY OF COASTAL SIGNS PLUS AND ITS ENTITIES. NO PART OF THIS DOCUMENT MAY BE COPIED, REPRODUCED OR DISTRIBUTED IN CONNECTION WITH THIS OR ANY OTHER WORK OR PROJECT FOR WHICH IT HAS BEEN PREPARED WITHOUT WRITTEN CONSENT FROM COASTAL SIGNS PLUS. IF, UPON SUBMITTAL TO A PROPOSED CLIENT, THESE DRAWINGS ARE NOT USED, THEY SHALL BE RETURNED TO COASTAL SIGNS PLUS IN THEIR ENTIRETY. FURTHERMORE, NO PART OF THESE DRAWINGS, OR THEIR LIKENESSES, SHALL BE REPRODUCED IN ANY FORM, INCLUDING PHOTOGRAPHS, DIGITAL IMAGES AND/OR SIGNAGE, WITHOUT EXPRESS WRITTEN CONSENT FROM COASTAL SIGNS PLUS. 1960 N. Marshall Ave. #101El Cajon, CA 92020 REVISIONS:CLIENT: DEL MAR PLAZA PROJECT: PROJECT NUMBER: 23-059 PROJECT MANAGER: MARK KRENN DATE: 01-2024 PHASE IISIGN ADDITIONS 4 STE. 108 Site Location Suite 106 Address: 6985 El Camino Real Suite 106 Carlsbad, CA 92009 I SIGN A 36’ __ _ _ Scope of Work: Sign A: (1) Illuminated Wall Sign 22.00” x 144.00” = 22.00 SF Vestar Property Management 2415 E Camelback Road Suite 100 Phoenix, AZ 85016 562.420.5104 KDudevoir@vestar.com Assessor’s Parcel #: 215-050-75-00 Project Title: Gems of La Costa GEMS OF LA COSTA NOT FOR SOUTH A& B, S S ON PAGE 12 I I I • I ' ---- --- $ ~ BUltDIN lOWfR L BUlkOIN LOWE/I ~ ------- w 2: :5 ~ lg \ -· - MARKET T NANT - THEATER TENANT PAD TENANTS - SHOP TENANTS (LOWER LEV LJ - SHOP TENANTS (UPPER Ll!VELJ BUILDING D UPPER LEVEL BUILDING E UPPER UV e NORTH 3 ST.1 - Side View 1 7/8" 4" THE FOLLOWING DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, CONCEPTS AND ARRANGEMENTS CONTAINED HEREIN ARE AND SHALL REMAIN THE PROPERTY OF COASTAL SIGNS PLUS AND ITS ENTITIES. NO PART OF THIS DOCUMENT MAY BE COPIED, REPRODUCED OR DISTRIBUTED IN CONNECTION WITH THIS OR ANY OTHER WORK OR PROJECT FOR WHICH IT HAS BEEN PREPARED WITHOUT WRITTEN CONSENT FROM COASTAL SIGNS PLUS. IF, UPON SUBMITTAL TO A PROPOSED CLIENT, THESE DRAWINGS ARE NOT USED, THEY SHALL BE RETURNED TO COASTAL SIGNS PLUS IN THEIR ENTIRETY. FURTHERMORE, NO PART OF THESE DRAWINGS, OR THEIR LIKENESSES, SHALL BE REPRODUCED IN ANY FORM, INCLUDING PHOTOGRAPHS, DIGITAL IMAGES AND/OR SIGNAGE, WITHOUT EXPRESS WRITTEN CONSENT FROM COASTAL SIGNS PLUS. 1960 N. Marshall Ave. #101El Cajon, CA 92020 REVISIONS:CLIENT: DEL MAR PLAZA PROJECT: PROJECT NUMBER: 23-059 PROJECT MANAGER: MARK KRENN DATE: 01-2024 PHASE IISIGN ADDITIONS ST1.2 // SIGN CABINET V3Fabrication Detail 2 NOTES AND SPECIFICATIONS 1.36" x 22" fabricated aluminum sign cabinet - sign shall be internally LED lighted with backed translucent acrylic and shall be painted with Matthews automotive grade paint. Sign shall face light and halo illuminate. 2.108" X 22" channel letter sign - internally LED illuminated channel letter signs with digital vinyl faces. Sign shall face and halo illuminate. Notes: Ease all edges and corners. 2 2 i n 1 8 i n 144 in 1 ST.1 - Front View 34 x22 Scale: 1:10 2 ST.1 - Front View Scale: 1:10 36’ GEMS OF LA COSTA Sign Area: 22.00” x 144.00” = 22.00 SF II4”34”106” 34” x 22” 106” x 22” SIGN A SIGN A Logo Box Channel Letters ---------------------- 0,------- ----------------------------------1 I I I I I I I THE FOLLOWING DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, CONCEPTS AND ARRANGEMENTS CONTAINED HEREIN ARE AND SHALL REMAIN THE PROPERTY OF COASTAL SIGNS PLUS AND ITS ENTITIES. NO PART OF THIS DOCUMENT MAY BE COPIED, REPRODUCED OR DISTRIBUTED IN CONNECTION WITH THIS OR ANY OTHER WORK OR PROJECT FOR WHICH IT HAS BEEN PREPARED WITHOUT WRITTEN CONSENT FROM COASTAL SIGNS PLUS. IF, UPON SUBMITTAL TO A PROPOSED CLIENT, THESE DRAWINGS ARE NOT USED, THEY SHALL BE RETURNED TO COASTAL SIGNS PLUS IN THEIR ENTIRETY. FURTHERMORE, NO PART OF THESE DRAWINGS, OR THEIR LIKENESSES, SHALL BE REPRODUCED IN ANY FORM, INCLUDING PHOTOGRAPHS, DIGITAL IMAGES AND/OR SIGNAGE, WITHOUT EXPRESS WRITTEN CONSENT FROM COASTAL SIGNS PLUS. 1960 N. Marshall Ave. #101El Cajon, CA 92020 REVISIONS:CLIENT: DEL MAR PLAZA PROJECT: PROJECT NUMBER: 23-059 PROJECT MANAGER: MARK KRENN DATE: 01-2024 PHASE IISIGN ADDITIONS ST1.2 // SIGN CABINET V3Fabrication Detail 3 NOTES AND SPECIFICATIONS 1.4” deep, .040” thick aluminum fabricated with black trim cap 2.1/4-20x4” screws and toggles. 3.Wire nut connection from secondary feed to leds. (class 2 low voltage). 4.Translucent white face 5.Secondary feed (class 2 low voltage from power supply to letter. 6.Translucent white face 7.12v power supply with aluminum service box 8.Class 2 led lighting. 9.#8 x 1/2” screws (min. Four (4) per character). 10.Drain holes (min one (1) per lowest point(s) per character). 11.To dedicated circuit, ac 100-240v 50/60hz. 12.Primary power supply NOTES AND SPECIFICATIONS 1.Internally illuminated aluminum sign cabinet with 4" deep returns and push thru 1/4" proud acrylic and digital vinyl faces 2.1/4-20x4” SMS screws 3.Wire nut connection from secondary feed to leds. (class 2 low voltage). 4..090 Aluminum Face 5.Secondary feed (class 2 low voltage from power supply to letter. 6.Translucent white face 7.12v power supply with aluminum service box 8.Class 2 led lighting. 9.Drain holes (min one (1) per lowest point(s) per character). 10.Push-through acrylic lettering, 1/4” proud. 11.To dedicated circuit, ac 100-240v 50/60hz. 12.Primary power supply 1 36" x 22" Fabricated Aluminum Sign Cabinet Scale: NTS 1 ⅞”4”1 ⅞”4” 2 108" X 22" Channel Letter Sign Scale: NTS GEMS OF LA COSTA Minimum (4) 34” x 22”106” x 22” / Minimum (6) / Min. (4) each Logo Box Channel Letters_______________________ 3 3 t t t t ~ LISTED 01------