Loading...
HomeMy WebLinkAboutPS 2024-0002; SPRINGHILL SUITES TOWER 69; Sign Permits/Programs (PS) P-11 Page 1 of 2 Rev. 3/22 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov SIGN PERMIT P-11 SUBMIT ONLINE THIS APPLICATION IS TO BE SUBMITTED ELECTRONICALLY. VISIT OUR ONLINE PERMIT PORTAL AT HTTPS://EG.CARLSBADCA.GOV/. NO PROCESSING WILL BEGIN UNTIL CITY HAS RECEIVED ALL REQUIRED SUBMITTAL ITEMS Background For land use permitting and requirements on signs, refer to chapter 21.41 of the Carlsbad Municipal Code, including an applicable specific plan, master plan or sign program. Depending on the scope of construction, a building permit may also be required. Please note ground-mounted/monument signs within the coastal zone also require a minor Coastal Development Permit. Requirements for signs may be subject to an existing sign program on file with the city. Have questions? Please visit the city website on options to contact Planning. TYPE OF PERMIT APPLYING FOR: Sign Permit (Also use for Temporary Banners and ground mounted/monument signs) Sign Program or Modified Sign Program? Use P-11(D) Name of Project: Related Planning Case Number(s), if any: PROPERTY OWNER/PROPERTY MANAGER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) MAILING ADDRESS MAILING ADDRESS CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. SIGNATURE DATE SIGNATURE DATE SC Hotel LLC - SpringHill Suites Carlsbad Belle Francisco 42 Corporate Park Ste 200 Irvine, CA 92606 7144274333 03.03.23abfrancisco PETER LAPSIWALA 9921 CARMEL MTN ROAD #327 SAN DIEGO CA 92129 12/03/23 01/10/2024 P-37 Page 1 of 1 Rev. 2/2022 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov Certificate of Accuracy P-37 Project Name__________________________ Type of permit(s) applying for____________________________ CITY OF CARLSBAD - PLANNING DIVISION CERTIFICATE OF ACCURACY I certify all documents and plans clearly and accurately show all existing and all proposed buildings, structures, access roads, and utilities/utility easements. All proposed land use activities, improvements to land, and/or building modifications or additions are clearly labeled on the site plan of the approved plan set. I understand that any potentially existing detail within these plans inconsistent with the site plan are not approved and may be required to be altered or removed. The submitted documents and plans show the correct dimensions of the property, the buildings, and structures and their setbacks from property lines and from one another, access roads/easements, and utilities. The existing and proposed use of land and of each building as stated is true and correct. Further, all improvements existing on the property were completed in accordance with all regulations in existence at the time of their construction, unless otherwise noted. All easements and other encumbrances to development have been accurately shown and labeled as well as all on-site grading/site preparation. Applicant: _______ Date: _____________ SPRINGHILL SUITES TOWER 69 WALL SIGN WALL SIGN PERMIT 01/10/2024 Development Services Planning Division 1635 Faraday Avenue (442) 339-2610 www.carlsbadca.gov PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 01/23/2024 PROJECT NAME: TOWER 39 PROJECT ID: PS2024-0002 PLAN CHECK NO: 1 ADDRESS: 3136 CARLSBAD BLVD APN: 203-250-26-00 This plan check review is complete and has been APPROVED by the Planning Division. By: Megan McElfish A Final Inspection by the Planning Division is required Yes No Note to city staff: (Planner will add inspection in Energov). Building Division will verify inspection is in Energov. You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments are available online at the following hyperlink: Carlsbad's Customer Self Service Portal. This hyperlink has been emailed to the applicant. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 442-339-2610 ENGINEERING 442-339-2750 FIRE PREVENTION 442-339-2665 Megan McElfish 442-339-5153 Megan.McElfish@carlsbadca.gov P-29 Page 2 of 2 07/11 Remarks: 1. PER CMC SECTION 21.41.080 E, WHEN THERE IS MORE THAN ONE SIGN ON A BUILDING, ALL SIGNS SHALL HAVE SIMILAR DESIGNS AND INCORPORATE THE SAME DESIGN ELEMENTS. PLEASE AMEND THE PROPSED SIGN (SIGN/LETTER COLOR, STYLE OF COPY, ETC.) TO SHOW THAT IT COMPLIES WITH THE CODE. PROJECT ADDRESS: Marriott Springhill Suites Carlsbad 3136 Carlsbad Blvd Carlsbad, CA 92008 APN: 203-250-26-00 ZONE: V-B LEGAL: TCT 100*0.69 AC M/L IN BLK 18 MP 775&IN\ PM 001661 CARLSBAD LANDS OWNER: SC HOTEL LLC 42 CORPORATE PARK SUITE 200 IRVINE CA 92606 714-427-7333 CONTRACTOR: MATTHEW SIGNS 560 S QUINCE STREET ESCONDIDO CA 92025 LIC#779468 SCOPE OF WORK: TO INSTALL (2) ILLUMINATED WALL SIGNS ALL WORK TO COMPLY WITH: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE MM 04/09/2024 PS2024-0002 ~ OSITE PLAN LINE OF UNDERGROUND PARKING GARAGE BELOW ----, i. ., 1 / / / .f--... ,;:=;;,=----i==j· -i--:--:--:-J. ~ -~-~·-__ • ,----------------- ' I I I I I I I I ._ __________ _, .. _ .... .,.._....J. __ ~ ______ IAMP OOH ________ ...!. TO PAIUl:ING ~ ' \ ~ ,.,_______ i'r \ ,.~.r~,_ __ __.//1.~-~-r----,__~--~~ J ___ r-- I i i ! PROPOSED SPRINGHILL SUITES I I I I I 1----------------------------·~-R ~sF===I= 3-STORY HOTEL WITH UNDERGROUND PARKING V-RZONING (4S'-0" HEIGHT LIMIT) F.F.E. = 53.90' R-3 ZONING (35'·0" HEIGHT LIMIT) ,----------------------. : ·~~~-~,: I I I I '-------------------------.,-'l=~~~~~+-'fll OVERALL ARCHITECTURAL SITE PLAN 1-w w a:: 1- Ul z -' 0 u z -' r I TOWER39 ROOFTOP LOUNGE Design# 0418858APr4 Sheet 4 of 4 I TOWER39 l. •• - 3136 Carlsbad Blvd. CARLSBAD, CA Account Rep. MD/MF Designer BR Date 10/11/22 Approval/ Date Client Sales Estimating Art Engineering Landlord Revision / Date Rl-AC-10/24/22: rev B,C add opt2 R2 RFF 12.15.22 revd a specs R3 ES 12/29 del A R4 TS-1/2/24: Revise site -add elev di m's, add dis-connect switches, Add Lag Bolts chandlersigns.com National 14201 Sovereign Road #101 Headquarters r2~ =-~~Q ri~ °{i~!15~z-z044 San Antonio 17319 San Pedro Avenue Suite200 San Antonio, TX 78232 (210)349-3804Fix(210)349-8724 2301 River Road, Suite 201 Northeast US Louisville, KY 40206 {S02)897-9800 Cell (502) 554-2575 111 Woodstone Place Georgia Dawsonville, GA 30534 l678)n5-885ZFax(Z10)349-8724 PO BOX 125 206 Doral Drive South Texas Portland, TX 78374 (361J563-5599Fax(361)643-6533 This drawing is the property of Chandler Signs, LLC All rights to its use for reproduction are reserved by Chandler Signs, LLC 4 0424472Ar1 MD/MF BR/RS 2 26 4/ /2 *Moved signs from previousdes n to new #ig above R1 JMC 4/2/24: REVISED SIGNA AND B TOWER39 3136 Carlsbad Blvd. CARLSBAD, CA EXISTING CONDITIONS @ SOUTH ELEVATION REMOVE EXISTING TRIM PIECE AS REQUIREDVERTICAL A PROPOSED SIGNAGE @ SOUTH ELEVATION MANUFACTURE & INSTALL ONE [1] NEW S/F ILLUMINATED SIGN CABINET 8'-3.75”±EqEq NOTE: TRIM REMOVAL & FASCIA RESTORATION - BY OTHERS 1 180'-0"± OAW 4 0424472Ar1 MD/MF BR/RS 2 26 4/ /2 *Moved signs from previousdes n to new #ig above R1 JMC 4/2/24: REVISED SIGNA AND B TOWER39 3136 Carlsbad Blvd. CARLSBAD, CA EXISTING CONDITIONS @ NORTH ELEVATION REMOVE EXISTING VERTICAL TRIM PIECE AS REQUIRED B PROPOSED SIGNAGE @ NORTH ELEVATION MANUFACTURE & INSTALL ONE [1] NEW S/F ILLUMINATED SIGN CABINET 8'-3.75”EqEq NOTE: - TRIM REMOVAL &FASCIA RESTORATION- BY OTHERS *TREE TRIMMING MAY BE REQUIRED FOR IMPROVED SIGN VISIBILITY* 2 184'-0"± OAW 4 0424472Ar1 MD/MF BR/RS 2 26 4/ /2 *Moved signs from previousdes n to new #ig above R1 JMC 4/2/24: REVISED SIGNA AND B TOWER39 3136 Carlsbad Blvd. CARLSBAD, CA B FACE LIT CHANNEL LETTER DISPLAY TWO [2] REQUIRED - MANUFACTURE & INSTALL SCALE: " = 1' - 0"1/2 8'-3.75 99.75" ( ”) A 3 FIELD SURVEY REQUIRED PRIOR TO MANUFACTURE. 2'-11.25" ALUMINUMRETURNS/ ALUMET PRE-FINISHED MATTE BLACK BLACK JEWELITE RETAINERS 2447 WHITE ACRYLIC FACES w/ 3635-7994 BLUE DUAL COLORFILMOVERLAYS GEWHITE LED INTERNAL ILLUMINATION PRE-FORMED ALUMINUM RETURNS PRE-FINISHED LIGHT-ENHANCING- WHITE INSIDE LETTER SECTION DETAIL PAIGE "WALL BUSTER" PLASTIC PASS-THRU PAIGE BOX GALVANIZED METAL POWER SUPPLY ENCLOSURE 1"JEWELITERETAINERS GE LED ILLUMINATION FLUSH MOUNTED TO WALL SURFACE WITH RIVNUT ANCHORS AS REQUIRED 5" ACRYLIC FACES 1/4"DIA. WEEP HOLES IN LOW POINTS w/ ALUMINUM LIGHT SCREENS@ EACH WEEP HOLE TO PREVENTLIGHT LEAKS 2447 WHITE ACRYLIC FACE w/ 3635-7994 BLUE DUAL COLOR FILMOVERLAY & WHITE BLOCK-OUTVINYL DETAILS SIMULATED NIGHT VIEW