HomeMy WebLinkAbout2622 HALF DOME PL; ; CBR2023-5404; PermitPrint Date: 06/19/2024
Building Permit Finaled
Residential Permit
CBR2023-5404Permit No:
Job Address:
Permit Type:
Parcel #:
Valuation:
Occupancy Group:
2622 HALF DOME PL, CARLSBAD, CA 92010-7912
BLDG-Residential
1675111400
$3,200.00
Work Class:
Lot #:
Project #:
SolarApp
Status:
Applied:
Issued:
12/29/2023
01/03/2024
Finaled Close Out:06/19/2024
#of Dwelling Units:
Track #:
Plan #:
Closed - Finaled
Plan Check #:
Orig. Plan Check #:Bathrooms:
Final Inspection:02/13/2024Bedrooms:Construction Type:
Occupant Load:
Code Edition:
Sprinkled:
INSPECTOR:de Roggenbuke, Dirk
STATMAN, 3.08KW, 8 MODULES, 1 INVERTER, 1 BATTERY (E-REVIEW)Description:
Project Title:
Applicant: MORIAH DOWELL
8090 ARJONS DR
SAN DIEGO, CA 92126-4303
CoApplicant: SUNRUN INSTALLATION SERVICES INC
PRISCILLA LOPEZ
1225 PARK CENTER DR
VISTA, CA 92081-8353
AMOUNTFEE
SB1473 – GREEN BUILDING STATE STANDARDS FEE $1.00
SOLAR–RESIDENTIAL: BATTERY BACK-UP $210.00
SOLAR–RESIDENTIAL: per kW $307.00
STRONG MOTION – RESIDENTIAL (SMIP)$0.50
Total Fees:$518.50 Total Payments To Date:$518.50 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad CA 92008-7314 ï 442-339-2719 ï 760-602-8560 f ï www.carlsbadca.gov
Building Division Page 1 of 1
{"Cityof
Carlsbad
SolarAPP+ Fire Bulletin
Disconnecting Means SolarAPP+ Fire Bulletin
PV System
PV system disconnecting means shall be provided in accordance with the 2020 National Electrical Code® (NEC), NFPA 70.(R) [690.13]
A Rapid Shutdown switch shall be provided at a readily accessible location outside the building in accordance with the 2020 National
Electrical Code® (NEC), NFPA 70.® [690.12(C)]
Energy Storage System
A disconnecting means is required for all ungrounded conductors derived from an ESS [NEC 706.15(A)]
Where remote actuation of the disconnecting means is employed the controls are not within sight of the ESS, the disconnecting means
shall be capable of being locked in the open position. [NEC 706.15(B); 110.25]
The disconnecting means can be integral to listed ESS equipment [NEC 706.15(A)]
The disconnecting means must be readily accessible [NEC 706.15(A)(1)]
Where circuits from the input or output terminals of energy storage components in an ESS pass through a wall, floor, or ceiling, a readily
accessible disconnecting means shall be provided within sight of the energy storage component. Fused disconnecting means or circuit
breakers shall be permitted to be used. [NEC 706.15(D); 706.31(F)]
The disconnecting means must be within sight of the ESS or as close as practicable with a marking [NEC 706.15(A)(2)]
The disconnecting means must be lockable open in accordance with 110.25 [NEC 706.15(A)(3)]
For one-family and two-family dwellings, a disconnecting means or its remote control shall be located at a readily accessible location
outside the building. [NEC 706.15(A)]
The marking for the ESS must indicate whether it is open or closed and be permanently marked “ENERGY STORAGE SYSTEM
DISCONNECT.” The disconnecting means must be legibly marked with nominal ESS ac voltage, maximum ESS dc voltage. [NEC
706.15(C)]
Signs, Placards, Directories, and Markings
Guidance
SolarAPP+ Fire Bulletin
General
All labeling shall comply with Section 324 of the 2021 International Residential Code and Articles 690 and 705 of the 2020 National
Electrical Code® (NEC), NFPA 70
All labeling shall comply with [NEC 110.21 (B)]
Rapid Shutdown Label
Buildings with more than one rapid shutdown type:
A detailed plan view diagram showing each PV system and a dotted line around areas that remain energized after the rapid shutdown
switch is operated. [NEC 690.56(C)]
Rapid Shutdown (PV Hazard Control) switch:
This switch shall have a label not greater than 3 feet from the switch that states the following:
RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM [NEC 690.56(C)(1)]
SolarAPP+ Fire Bulletin
Approval ID: SA20231222-970-105-7-A
Reviewed for Code compliance
12-22-2023
SolarAPP+Page 8/42
NEC 2020 PV+ST (rev_k)
~
Solar APP+
Roof Access, Egress, and Ventilation
General
Access and minimum spacing shall be provided for access to specific areas of the roof, emergency egress from the roof and opportunities
for smoke ventilation in accordance with the 2021 International Residential Code [IRC 324.6]
References:
Ridge Setbacks - [IRC R324.6.2]
Sprinklered Occupancies - [IRC R324.6.2.1]
Pathways - [IRC 324.6.1]
Emergency escape and rescue openings - [IRC R324.6.3]
Exceptions:
Detached, non-inhabitable structures [IRC R324.6 Ex. 1]
Low-slope roofs with pitch of less than or equal to 2:12; this exception may not be valid depending on the jurisdiction. [IRC R324.6 Ex. 3]
BIPV systems listed and labeled in accordance with Section 690.12(B)(2) of NFPA 70, where the removal or cutting away of portions of the
BIPV system during fire-fighting operations has been determined to not expose a fire fighter to electrical shock hazards. [IRC R324.6 Ex. 4]
Carbon Monoxide, Smoke & Heat Detectors SolarAPP+ Fire Bulletin
Guidance:
Where required, Carbon Monoxide and smoke detectors shall be provided in accordance with the code or an Affidavit has been provided
by the customer. 2021 International Residential Code.[R314, R315]
Rooms and areas within dwelling units, basements and attached garages in which ESS are installed shall be protected by smoke alarms in
accordance to the code. A heat detector, listed and interconnected to the smoke alarms, shall be installed in locations within dweling units
and attached garages where smoke alarms cannot be installed based on their listing. 2021 International Residential Code.[R314, R315,
R328.7]
Energy Storage System SolarAPP+ Fire Bulletin
Special Considerations
ESS shall not be installed in sleeping rooms, or closets or spaces opening directly into sleeping rooms. [IRC R328.4]
Aggregate energy ratings shall not exceed:
40kWh within utility closets, basements, and storage or utility spaces
80kWh in attached or detached garages and detached accessory structures
80kWh on exterior walls
80kWh outdoors on the ground
0kWh in habitable space [IRC R328.4,R328.5]
When the ESS is installed in a location subject to vehicle damage it shall be protected by approved barriers. [IRC R328.8]
ESS installed indoors that produce hydrogen or other flammable gases during charging shall be provided with either natural or mechanical
ventilation in accordance with Section M1307.4.1 or M1307.4.2. [IRC R328.9; M1307.4]
Approval ID: SA20231222-970-105-7-A
Reviewed for Code compliance
12-22-2023
SolarAPP+Page 9/42
NEC 2020 PV+ST (rev_k)
~
Solar APP+
Individual energy storage systems shall be separated from each other by at least three feet of spacing unless smaller separation distances
are documented to be adequate as approved by the code official based on large scale fire testing. [IRC R328.3.1]
Individual ESS unit ratings shall not exceed 20kWh. [IRC R328.5]
ESS shall be installed only in the following locations:
1. Detached garages and detached accessory structures.
2. Attached garages separated from the dwelling unit living space in accordance with the Code.
3. Outdoors or on the exterior side of exterior walls located not less than 3 feet (914 mm) from doors and windows directly entering the
dwelling unit.
4. Enclosed utility closets, basements, storage or utility spaces within dwelling units with finished or noncombustible walls and ceilings.
Walls and ceilings of unfinished wood-framed construction shall be provided with not less than 5/8 inch Type X gypsum wallboard. [IRC
R328.4]
Documentation and labeling
A copy of the manufacturer's installation, operation, maintenance and decommissioning instructions shall be provided to the owner or
placed in a conspicuous location near the ESS equipment. [IRC R328.11]
A label on the installed system containing the contact information for the qualified maintenance and service providers. [IRC R328.11]
Fire Classification SolarAPP+ Fire Bulletin
PV System
Rooftop-mounted PV systems shall have the same fire classification as the roof assembly required in 2021 International Residential Code.
[R902.4; R324.4.2]
Building-integrated photovoltaic products installed as the roof covering shall be tested, listed, and labeled for fire classification. [IRC
R902.3, R324.5.2]
Building-integrated photovoltaic products installed as the roof covering shall comply with the minimum requirements for fire classification
set by the jurisdiction. [IRC R902.1]
Product Certifications SolarAPP+ Fire Bulletin
PV System
PV panels and modules shall be listed and labeled to UL 1703 and/or both UL 61730-1 and UL 61730-2 [NEC 690.4(B)][IRC R324.3.1]
Inverters shall be listed and labeled to UL 1741 [NEC 690.4(B)][IRC R324.3.1]
Hazard Control System
Hazard control system shall be listed and labeled to UL 3741 [NEC 90.7; 110.3(C); 690.4(B); 690.12(B)(2)(1); 690.12(D)]
Energy Storage System
The ESS inverter, for AC Coupled systems, shall be listed and labeled to UL 1741 [IRC R328.6]
The ESS shall be listed and labeled to UL 9540 [IRC R328.2]
The ESS Microgrid Interconnection Device shall be listed and labeled to UL 1741 [IRC R328.6]
Approval ID: SA20231222-970-105-7-A
Reviewed for Code compliance
12-22-2023
SolarAPP+Page 10/42
NEC 2020 PV+ST (rev_k)
I
I
~
Solar APP+
Building Permit Inspection History Finaled
PERMIT INSPECTION HISTORY for (CBR2023-5404)
BLDG-Residential 12/29/2023Application Date:Permit Type:Owner:
SolarApp 01/03/2024Work Class:Issue Date:Subdivision:CARLSBAD TCT#84-35 UNIT#01
08/12/2024Expiration Date:Status:
IVR Number: 54055
Closed - Finaled 2622 HALF DOME PL
CARLSBAD, CA 92010-7912
Address:
Scheduled
Date
Inspection Type Inspection No. Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
02/13/2024 02/13/2024 BLDG-34 Rough
Electrical
239476-2024 Passed Dirk de Roggenbuke Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency ESS Yes
BLDG-35 Solar Panel 239194-2024 Passed Dirk de Roggenbuke Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
BLDG-Electric Meter
Release
239477-2024 Passed Dirk de Roggenbuke Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
BLDG-Final Inspection 239478-2024 Passed Dirk de Roggenbuke Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Tuesday, February 13, 2024 Page 1 of 1